CMT MANUAL 6. NMC SENSORS
|
|
- Jade Mason
- 5 years ago
- Views:
Transcription
1 CMT MANUAL 6. NMC SENSORS
2 TABLE OF CONTENTS INDEMNITY... 5 DOCUMENT INFORMATION... 5 ACKNOWLEDGEMENTS INTRODUCTION TEMPERATURE AND HUMIDITY SENSORS TEMPERATURE SENSOR TEMPERATURE SENSOR SPECIFICATIONS TEMPERATURE SENSOR CONNECTIONS HUMIDITY SENSOR HUMIDITY SENSOR SPECIFICATIONS HUMIDITY SENSOR CONNECTIONS HUMIDITY SENSOR CLEANING AND MAINTENANCE INSIDE TEMPERATURE AND HUMIDITY BOX INSTALLATION WIND SPEED AND DIRECTION SENSOR WIND SPEED AND DIRECTION SENSOR SPECIFICATIONS WIND SPEED AND DIRECTION SENSOR CONNECTIONS WIND SPEED AND DIRECTION SENSOR INSTALLATION AND ORIENTATION WIND SPEED AND DIRECTION SENSOR MAINTENANCE RAIN SENSORS RAIN DETECTOR SENSOR RAIN DETECTOR SENSOR SPECIFICATIONS RAIN DETECTOR SENSOR CONNECTIONS RAIN DETECTOR SENSOR MOUNTING RAIN DETECTOR SENSOR INSTALLATION AND MAINTENANCE RAIN COLLECTOR SENSOR RAIN COLLECTOR SENSOR SPECIFICATIONS RAIN COLLECTOR SENSOR CONNECTIONS RADIATION SENSORS RADIATION SENSOR DAVIS RADIATION SENSOR DAVIS - SPECIFICATIONS RADIATION SENSOR DAVIS - CONNECTIONS Version 2.01 JA NMC Sensors Page 1
3 6.6.2 RADIATION SENSOR NETAFIM RADIATION SENSOR NETAFIM - SPECIFICATIONS RADIATION SENSOR NETAFIM - CONNECTIONS RADIATION SENSOR NETAFIM MAINTENANCE CO 2 SENSOR CO2 SENSOR SPECIFICATIONS CO2 SENSOR MAINTENANCE WEATHER SENSOR MOUNTING ARM INSTALLATION Version 2.01 JA NMC Sensors Page 2
4 LIST OF TABLES TABLE 1. TEMPERATURE SENSOR SPECIFICATIONS... 8 TABLE 2 TEMPERATURE SENSOR CONNECTIONS... 8 TABLE 3. HUMIDITY SENSOR SPECIFICATIONS... 9 TABLE 4. HUMIDITY SENSOR CONNECTIONS... 9 TABLE 5. WIND SPEED AND DIRECTION SENSOR SPECIFICATIONS TABLE 6. WIND SPEED AND DIRECTION SENSOR CONNECTIONS TABLE 7. RAIN DETECTOR SENSOR SPECIFICATIONS TABLE 8. RAIN DETECTOR SENSOR CONNECTIONS TABLE 9. RAIN COLLECTOR SENSOR SPECIFICATIONS TABLE 10. RAIN COLLECTOR SENSOR CONNECTIONS TABLE 11. RADIATION SENSOR DAVIS - SPECIFICATIONS TABLE 12. RADIATION SENSOR DAVIS - CONNECTIONS TABLE 13. RADIATION SENSOR NETAFIM - SPECIFICATIONS TABLE 14. RADIATION SENSOR NETAFIM - CONNECTIONS TABLE 15. CO2 SENSOR SPECIFICATIONS LIST OF FIGURES FIGURE 1. TEMPERATURE SENSOR... 7 FIGURE 2. INSIDE CLIMATE BOX... 7 FIGURE 3. OUTSIDE SHIELD COVER... 7 FIGURE 4. HUMIDITY SENSOR... 9 FIGURE 5. HUMIDITY SENSOR TIP WITH PROTECTIVE COVERS REMOVED FIGURE 6. HUMIDITY SENSOR TIP REPLACEMENT FIGURE 7. TEMPERATURE AND HUMIDITY BOX MOUNTED IN A GREENHOUSE FIGURE 8. WIND SPEED AND DIRECTION SENSOR FIGURE 9. WIND SENSOR COMPONENTS FIGURE 10. REMOVE WIND VANE FIGURE 11. ZERO THE WIND DIRECTION SHAFT FIGURE 12. WIND SENSOR NOSE AND ARM IN SAME DIRECTION FIGURE 13. PUSH THE WIND VANE DOWN ONTO THE SHAFT FIGURE 14. FIX THE WIND VANE TO THE SHAFT Version 2.01 JA NMC Sensors Page 3
5 FIGURE 15. ORIENT THE WIND SENSOR ARM FIGURE 16. RAIN DETECTOR SENSOR MOUNTING FIGURE 17. RAIN COLLECTOR SENSOR FIGURE 18. RADIATION SENSOR DAVIS FIGURE 19. RADIATION SENSOR NETAFIM FIGURE 20. CO 2 SENSOR FIGURE 21. WEATHER SENSOR MOUNTING ARM AND SENSORS Version 2.01 JA NMC Sensors Page 4
6 INDEMNITY Netafim South Africa (Pty) Ltd has taken all reasonable care in ensuring the integrity and reliability of the information contained in this document. Despite this Netafim South Africa (Pty) Ltd. takes no responsibility for any damage or loss that may result from the use of this manual. This document should be regarded as the property of Netafim South Africa (Pty) Ltd. This document is not intended for further training and neither may it be reproduced nor copied in its current form or temporary form. This document may not be revealed and/or carried over to any third party without the explicit written consent of Netafim South Africa (Pty) Ltd. This document is presented with the exclusive aim of notifying selected potential clients regarding NMC Sensors. Receipt or the possession of this document does not imply rights and the contents should be viewed as a proposal only. This document is neither issued as a guarantee, nor does it confirm any legal obligations on Netafim South Africa (Pty) Ltd whatsoever. Netafim South Africa (Pty) Ltd reserves the right to make changes in its products and in the NMC Sensors without prior notice. DOCUMENT INFORMATION Version: 2.01 Last updated: 19 January 2012 ACKNOWLEDGEMENTS Netafim South Africa Version 2.01 JA NMC Sensors Page 5
7 6.1 INTRODUCTION The NMC Climate Sensors available can be used on the following controller models: NMC Junior, NMC 64 Climate, NMC Pro and NMC DC. Not all of the sensors can be connected to all of the controller models. These connections are explained in Section 2 Installation - Hardware of the CMT Manual. Further, refer to 1.4 CMT Specifications and Limitations for the quantity of various sensors that can be configured to each controller. NMC Climate Sensors available include: Inside and/or Outside Temperature Inside and/or Outside Humidity Rain Sensor ON/OFF to indicate rain status Rain Collector to measure rain quantity Wind Speed and Direction Radiation sensor (DAVIS) to measure radiation level Radiation sensor (NETAFIM) to measure radiation level and sum. CO2 sensor The temperature and humidity sensors can be installed in a climate box or in shield covers. The climate box will be installed inside a greenhouse to measure climate compartment conditions and include a fan to circulate greenhouse air over the sensors.. The shield cover will be used with the weather station to measure outside climatic conditions. All weather station sensors can be mounted on a mounting arm bracket. This bracket will ensure the correct installation of sensors and simplify the installation. Version 2.01 JA NMC Sensors Page 6
8 6.2 TEMPERATURE AND HUMIDITY SENSORS TEMPERATURE SENSOR FIGURE 1. TEMPERATURE SENSOR FIGURE 2. INSIDE CLIMATE BOX FIGURE 3. OUTSIDE SHIELD COVER Version 2.01 JA NMC Sensors Page 7
9 TEMPERATURE SENSOR SPECIFICATIONS TABLE 1. TEMPERATURE SENSOR SPECIFICATIONS Details Units Input voltage 1 to 40 VDC Output current 1 μa for 1 kelvin Operating temperature -25 to 100⁰C Maximum error with no calibration ±3% TEMPERATURE SENSOR CONNECTIONS TABLE 2 TEMPERATURE SENSOR CONNECTIONS Wire colour Red Black Shield Description Output 3 kω Common Earth Version 2.01 JA NMC Sensors Page 8
10 6.2.2 HUMIDITY SENSOR FIGURE 4. HUMIDITY SENSOR See Figure 2 for the Inside climate box and Figure 3 for the Outside shield cover, in either of which the sensor may be fitted HUMIDITY SENSOR SPECIFICATIONS TABLE 3. HUMIDITY SENSOR SPECIFICATIONS Details Units Input voltage Output voltage Operating temperature 8 to 14 VDC 0 to 3 VDC -10 to 70⁰C RH range 0 to 100% Accuracy: RH 10 to 90% RH 90 to 100% ±2.0% ±3.5% HUMIDITY SENSOR CONNECTIONS TABLE 4. HUMIDITY SENSOR CONNECTIONS Wire colour Red Black White Shield Description 12 VDC Common 0 to 3 VDC output Earth Version 2.01 JA NMC Sensors Page 9
11 HUMIDITY SENSOR CLEANING AND MAINTENANCE Open the humidity sensor by unscrewing the sensor filter cover and remove the filter before cleaning. Clean the filter every 6 months or as required. Use water only. Avoid touching the sensor during the cleaning process. NB Warning. Water may damage the sensor. Make sure that the sensor is sealed whilst washing or in contact with water. FIGURE 5. HUMIDITY SENSOR TIP WITH PROTECTIVE COVERS REMOVED FIGURE 6. HUMIDITY SENSOR TIP REPLACEMENT Humidity sensor Hold the tip here. Do not touch the humidity sensor itself. The sensor tip will require replacement eventually, to insure correct humidity readings. When replacing the sensor tip, make sure that you fit it in the right direction. The sensor tip will fit into the socket in one direction only (see Figure 6). Version 2.01 JA NMC Sensors Page 10
12 6.2.3 INSIDE TEMPERATURE AND HUMIDITY BOX INSTALLATION The NMC Inside Temperature and Humidity Box is supplied with a galvanized mounting chain and hook for installation. All spare parts (sensors, fan and bridge rectifier) are sold separate, so it will not be necessary to replace a complete box under normal operating conditions. Consider the following during installation: Maximum preferred cable length (0.8mm) from Box to NMC controller is 100m Install one box per 2500 m² of greenhouse area Install the galvanized hook at the box, to enable height adjustment of the box as the crop height changes Minimum distance from greenhouse structure 0.5m In lightning prone areas, do not fasten the mounting chain to the greenhouse structure, use a length of rope and install only enough chain for box height adjustment. This will isolate the box from the greenhouse structure and prevent lightning damage to the NMC Controller Version 2.01 JA NMC Sensors Page 11
13 Climate box Mounting Bracket Eye Bolt Commercial Clamp 5mm GI Wire rope 20mm PVC Cable Conduit fixed to Wire Rope with Cable ties Nylon Rope Fitted for Lightning Protection Double Jacket 6 Core Cable fixed to chain with Cable Ties Climate box Mounting Chain Climate box S-Hook (adjust box height as required) NMC Inside Temp + RH Box Greenhouse post FIGURE 7. TEMPERATURE AND HUMIDITY BOX MOUNTED IN A GREENHOUSE Version 2.01 JA NMC Sensors Page 12
14 6.4 WIND SPEED AND DIRECTION SENSOR FIGURE 8. WIND SPEED AND DIRECTION SENSOR WIND SPEED AND DIRECTION SENSOR SPECIFICATIONS TABLE 5. WIND SPEED AND DIRECTION SENSOR SPECIFICATIONS Subject Details Sensor type Wind speed Wind cups and magnetic switch Wind direction Wind vane and potentiometer Material Wind vane and control head UV-Resistant ABS Wind cups Polycarbonate Anemometer arm Anodised aluminium General specifications Attached cable length 12 m Maximum cable length 100 m Cable type 4 conductor, 0.5 mm² Connector Modular connector (RJ-11) Dimensions 89mm x 83mm x 38mm Weight kg Range Wind speed km/h Wind direction 0⁰- 360⁰ Accuracy Wind speed ±5% Wind direction ±7% Resolution Wind speed 1km/h Wind direction 1⁰ (1⁰ to 355⁰) Version 2.01 JA NMC Sensors Page 13
15 6.4.1 WIND SPEED AND DIRECTION SENSOR CONNECTIONS TABLE 6. WIND SPEED AND DIRECTION SENSOR CONNECTIONS Wire colour Red Black Yellow Green Description Common Digital input - wind speed 5 VDC Sensor supply voltage Analogue input - wind direction WIND SPEED AND DIRECTION SENSOR INSTALLATION AND ORIENTATION Wind speed and direction sensor Wind speed and direction sensor arm Weather station mounting arm Weather station pole FIGURE 9. WIND SENSOR COMPONENTS Install the weather station sensors onto the weather station mounting arm. Install the weather station onto the supplied pole. Wire the sensors into the controller making sure that there is enough slack on the cable to mount the pole in its place later. Before mounting the pole, check the wind direction value. Loosen the grub screw and remove the Wind Vane. FIGURE 10. REMOVE WIND VANE Version 2.01 JA NMC Sensors Page 14
16 Using your fingers, turn the stainless steel wind direction shaft until the value on the NMC controller is 0. Allow 5 seconds for the value to stabilize before checking it. (Figure 11) FIGURE 11. ZERO THE WIND DIRECTION SHAFT Replace the wind vane with the bullet-shaped nose pointing in the same direction as the Wind speed and direction arm. (Figure 12) FIGURE 12. WIND SENSOR NOSE AND ARM IN SAME DIRECTION Push the wind vane onto the stainless steel shaft. Take care not to disturb the position of the shaft when doing this. (Figure 13) FIGURE 13. PUSH THE WIND VANE DOWN ONTO THE SHAFT Version 2.01 JA NMC Sensors Page 15
17 Fasten the grub screw to hold the wind vane in place. (Figure 14) FIGURE 14. FIX THE WIND VANE TO THE SHAFT Your Wind Direction pointer is now oriented to 0. Install the pole onto its brackets but do not tighten the u-bolts yet. Using a compass, turn the pole until the Wind Speed and Direction arm is pointing north. (Figure 15) North FIGURE 15. ORIENT THE WIND SENSOR ARM Fix your pole to the bracket. The weather station is now installed. See 6.8 Weather Sensor Mounting Arm Installation WIND SPEED AND DIRECTION SENSOR MAINTENANCE The NMC Wind Speed and Direction sensor does not require regular maintenance, nevertheless in highly polluted conditions it is recommended to clean the sensor surfaces with clean water from time to time. Version 2.01 JA NMC Sensors Page 16
18 6.5 RAIN SENSORS RAIN DETECTOR SENSOR RAIN DETECTOR SENSOR SPECIFICATIONS TABLE 7. RAIN DETECTOR SENSOR SPECIFICATIONS Details Units Power voltage 9 VAC Power consumption (electronic + heating) 3 VA Ambient temperature -20⁰ to 60⁰C Storage temperature -30 to 70 C for relative humidity of 0 to100% Drop-out time 5 minutes (±20%) Relay output 10 A, 250 VAC Housing material PVC Protection class IP 66 Weight including mounting and power supply 0.9 kg RAIN DETECTOR SENSOR CONNECTIONS TABLE 8. RAIN DETECTOR SENSOR CONNECTIONS Wire colour White Green Normally closed Common Description Connect white terminal of power supply to white terminal of sensor Connect green terminal of power supply to green terminal of sensor Digital Input Digital Input Common RAIN DETECTOR SENSOR MOUNTING Screw the mounting plate to a solid mounting surface or to the weather station mounting arm through the access holes. Open the box and attach it to the mounting plate as shown in Figure 14. Version 2.01 JA NMC Sensors Page 17
19 FIGURE 16. RAIN DETECTOR SENSOR MOUNTING RAIN DETECTOR SENSOR INSTALLATION AND MAINTENANCE The installation of the rain detector, its connection to a controller and its power supply is explained by the wiring detailed in Section Connection Wiring Rain Sensor (On/off) of the CMT Manual. Power must be disconnected prior to opening the enclosure to avoid electrical shock. The Rain Detector does not require regular maintenance, nevertheless in highly polluted conditions it is recommended to clean the sensor surface with clean water from time to time. Version 2.01 JA NMC Sensors Page 18
20 6.5.2 RAIN COLLECTOR SENSOR The NMC Rain Collector measures rainfall quantities. When using a Rain Collector it is not necessary to use a Rain Detector. The NMC controller will be put in a rain status by its software as soon as rainfall is being measured. The rain sensor consists of a measuring spoon that flips every time it accumulates a specific quantity. Every flip is counted and transformed to quantities FIGURE 17. RAIN COLLECTOR SENSOR RAIN COLLECTOR SENSOR SPECIFICATIONS TABLE 9. RAIN COLLECTOR SENSOR SPECIFICATIONS Sensor Type Output Subject Attached Cable Length Maximum Cable Length Cable type Housing Material. Diameter Details Tipping bucket with magnetic reed switch Dry contact 12 m 100 m 2-conductor, 0.5 mm² mm 165 mm Height 240 mm Collection Area 200 cm 2 Weight Resolution. Accuracy. 1 kg UV-stabilized ABS plastic ±3%, ±1 Rainfall count between 50.0 mm and mm/h ±2%, ±1 Rainfall count between 0.20 mm and 50.0 mm/h Version 2.01 JA NMC Sensors Page 19
21 RAIN COLLECTOR SENSOR CONNECTIONS TABLE 10. RAIN COLLECTOR SENSOR CONNECTIONS Wire colour Red Black Description Digital input Common Version 2.01 JA NMC Sensors Page 20
22 6.6 RADIATION SENSORS RADIATION SENSOR DAVIS This radiation sensor is a photodiode type sensor that measures light intensity. It is normally used for climate control and not irrigation control. FIGURE 18. RADIATION SENSOR DAVIS Version 2.01 JA NMC Sensors Page 21
23 RADIATION SENSOR DAVIS - SPECIFICATIONS TABLE 11. RADIATION SENSOR DAVIS - SPECIFICATIONS Sensor Type Subject Spectral range (10% points) Attached cable length Details Silicon photodiode 400 to 1100 nanometres 12 m Maximum cable length 100 m Cable type 4-conductor, 0.5 mm 2 Connector Housing material Dimensions Weight Cosine response Modular connector (RJ-11) UV-resistant plastic 51 mm x 70 mm x 57 mm 0.34 kg Percent of reading ±3% (0 to ±70 incident angle) ±10% (70 to ±85 incident angle) Percent of full-scale ±2% (0 to ±90 ) Range Solar radiation intensity Solar energy Accuracy 0 to 1500 W/m² 0 to 1999 Langleys Solar global radiation intensity ±5% Solar energy ±5% Resolution Solar radiation intensity Solar energy 1 W/m² 1 Langley Temperature coefficient % per ⁰C Reference temperature = 22⁰C RADIATION SENSOR DAVIS - CONNECTIONS TABLE 12. RADIATION SENSOR DAVIS - CONNECTIONS Wire colour White Red Yellow Description Output (0 to +3VDC); 1.67 mv per W/m² Common +5 VDC ±10%; 3mA (typical) Version 2.01 JA NMC Sensors Page 22
24 6.6.2 RADIATION SENSOR NETAFIM This radiation sensor is normally used for radiation sum irrigation control. FIGURE 19. RADIATION SENSOR NETAFIM RADIATION SENSOR NETAFIM - SPECIFICATIONS TABLE 13. RADIATION SENSOR NETAFIM - SPECIFICATIONS Subject Details Measuring principle Temperature difference Spectral range 300 to 2800 nanometres Power supply V Power consumption < 1 W Impedance < 50 Ω Sensitivity 2mV per W/m² Housing IP67 Accuracy daily sum Better than 10% Zero offset < 20 W/m² Connections 3 Wire: Supply, Output and Ground Dimensions 80mm x 55mm Version 2.01 JA NMC Sensors Page 23
25 RADIATION SENSOR NETAFIM - CONNECTIONS TABLE 14. RADIATION SENSOR NETAFIM - CONNECTIONS Wire colour White Brown Green Black Description Analogue input 12 DVC sensor supply Common Earth RADIATION SENSOR NETAFIM MAINTENANCE The NMC Radiation Sensor Netafim does not require regular maintenance, nevertheless in highly polluted conditions it is recommended to clean the sensor dome with clean water from time to time. Version 2.01 JA NMC Sensors Page 24
26 6.7 CO 2 SENSOR The CO2 measurement is based on non-dispersive infrared (NDIR) technology. The auto-calibration procedure compensates for aging of the infrared source and guarantees high reliability, long term stability and eliminates the need of periodical calibration in the field. FIGURE 20. CO 2 SENSOR CO2 SENSOR SPECIFICATIONS TABLE 15. CO2 SENSOR SPECIFICATIONS Subject Details Measuring principle Non-dispersive infrared (NDIR) technology Measuring range ppm Supply Voltage 24 VAC ±20% Power consumption < 3 W Warm up time < 5 min Sampling rate 30 sec Housing IP65 Accuracy at 20 C and 1013 mbar < ± (50ppm +5% of measured value) Long term stability Typically 20ppm / year Working conditions -20 to 60 C and 0 to 100% RH Dimensions (W x H x D) 80mm x 80mm x 50mm CO2 SENSOR MAINTENANCE The NMC CO2 Sensor does not require regular maintenance, nevertheless in highly polluted conditions it is recommended to clean the sensor outside with a clean damp cloth Version 2.01 JA NMC Sensors Page 25
27 6.8 WEATHER SENSOR MOUNTING ARM INSTALLATION The NMC Weather Sensor Mounting Arm is made from aluminium and supplied with all the screws and clamps required to install the weather station sensors. Consider the following during installation: Maximum cable length (0.8mm OD) from weather station to NMC controller is 100m Minimum height above the highest structure (greenhouse, pump room or farm office) surrounding the weather station installation is 1m Install weather station with wind speed and direction sensor black support arm pointing north Install rain sensor (ON/OFF) facing the prevailing rain direction Level weather station for accurate sensor readings In lightning prone areas earth the weather station installation with at least a 10mm² earth cable, connect earth of weather station to earth of NMC controller and protect with a lightning rod. Solar radiation Outside temperature and humidity Wind speed and direction Rain (on/off) Weather station mounting arm Mounting pole Rain collector FIGURE 21. WEATHER SENSOR MOUNTING ARM AND SENSORS Version 2.01 JA NMC Sensors Page 26
LC1350 Level Controller
LC1350 Controller Description The Spirax Sarco LC1350 has two alarm channels that can be independently configured high or low to control the water level of a boiler, tank or vessel by operating a pump,
More informationHOBO U30 Remote Monitoring Systems
onset HOBO U30 Remote Monitoring Systems Web-based environmental monitoring All electronics housed within a research-grade, tamperproof enclosure Setup is quick and easy with plug-and-play sensors GSM
More informationAnalog Room Pressure Monitor RPC Series
Description The Room Pressure Monitor is used to measure differential pressure in the range of 0.125 to 1"wc or 30 to 250 Pa. It combines precision high sensitivity silicon sensing capabilities and the
More informationRH & T Sensors & Humidistats. RH-DT Duct Mount RH & T Sensors. Description
RH & T Sensors & Humidistats RH-DT Duct Mount RH & T Sensors Description RH-DT Duct Mount RH & T Sensors The RH-DT Duct Mounted Humidity and Temperature Sensors offer the latest technology for high accuracy
More informationGas Safety Products. Installation, operating and maintenance. Merlin CO2 Monitor 4500PPM. Merlin CO2 Monitor. Rev: 11 Date:
Gas Safety Products 4500PPM Installation, operating and maintenance Read these instructions carefully before operating or servicing Rev: 11 Date: 09-07-18 1 * The unit should be installed by a competent
More informationRS Pro Infrared Temperature Sensor
Instruction Manual RS Pro Infrared Temperature Sensor Stock Number: 161-8103 Introduction The RS Pro Infrared Temperature Sensor is a device for measuring the temperature of the surface of a solid or liquid
More informationHYGROMER MP 100 A Meteorology probe
HYGROMER MP 100 A Meteorology probe Bedienungsanleitung Mode d emploi Operating Instructions 1. Introduction With the HYGROMER meteorology probe MP 100A for measuring humidity and temperature, you have
More informationANEMOMETER 4403-RF-BAT
ANEMO 4403 Radio impulsive output Anemometer - Wireless Robust wind speed sensor,extremely resistant and flexible, Suitable for many different application. Stainless steel bearings and high quality technical
More informationSAFETY INFORMATION AND WARNINGS
This manual refers to the Model SST-3 control panel manufactured since October 31, 2013, which uses a universal (100 277 VAC; 50/60 Hz) power supply. Older units use a voltage-specific power supply and
More informationDESIGN MANUAL. The information in this doucment is applicable to sensors built in September, 2009 or later (Firmware 3.0)
DESIGN MANUAL MODEL GIR910 INFRARED CARBON DIOXIDE (CO 2 ) GAS SENSOR 70091 The information in this doucment is applicable to sensors built in September, 2009 or later (Firmware 3.0) The information and
More informationFT702LT Turbine control wind sensor gives durability a new meaning FT702LT. series
FT702LT Turbine control wind sensor......gives durability a new meaning FT702LT series Proven High Availability The FT702LT ultrasonic anemometer is the result of FT Technologies 10 years of experience
More informationI NTEGRATED S ENSOR S UITE WITH F AN-ASPIRATED R ADIATION SHIELD ADDENDUM, REV B. For Vantage Pro and Vantage Pro Plus
I NTEGRATED S ENSOR S UITE WITH F AN-ASPIRATED R ADIATION SHIELD ADDENDUM, REV B For Vantage Pro and Vantage Pro Plus The Vantage Pro Integrated Sensor Suite (ISS) with the Fan-Aspirated Radiation Shield
More informationBC3250. Blowdown Controller
Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without
More informationFCHM Hydromatic Pump Control Module
FCHM Hydromatic Pump Control Module Use To maintain and control water pressure, within a pumped system, for the supply to industrial processes and heating systems. Ensures constant flow and pressure to
More informationRota-Sonde DC4000-L. Laser pointer for easy alignment. Remote control of the sensitivity
Scanning HOT METAL DETECTOR Rota-Sonde DC4000-L Two sensitivity ranges : 400 C and 230 C Laser pointer for easy alignment Remote control of the sensitivity Self-monitoring ISO 9001 Applications Benefits
More informationTrueAlarm Analog Sensing
TrueAlarm Analog Sensing UL, ULC Listed* Addressable Duct Sensor Housings with TrueAlarm Photoelectric Sensor; Available with Multiple Relay Features Compact air duct sensor housing with clear cover to
More informationAppearance and sensing characteristic Specification (temperature range) Model 10 to 70 C ES1B. 2 mm 20 mm 40 mm 60 mm. 40 dia. 60 dia.
Infrared Thermosensor CSM DS_E_3_2 Achieve Low-cost Measurements with an Infrared Thermosensor. The has an electromotive output as high as that of a thermocouple, thus connecting directly to the thermocouple
More informationMovement Detector GJD 300
Movement Detector GJD 300 Installation & Set Up Guide Introduction A CCTV event trigger utilising two independent passive infrared detectors combined in a T05 package. Both sensors have to trigger before
More informationHygro Transducer / Hygrothermal Transducer and CO 2 Measuring Probe for Climate Monitoring
Data Sheet 907021 Page 1/8 Hygro Transducer / Hygrothermal Transducer and CO 2 Measuring Probe for Climate Monitoring For measuring relative air humidity, temperature, and carbon dioxide concentration
More informationDIGITAL METERS Large Display Temperature Meters Instruction Manual
DIGITAL METERS Large Display Temperature Meters PD755 PD756 PD757 Handles Thermocouple & RTD Inputs with Simplicity J, K, T, E, R, & S Thermocouples 100 Ω Platinum RTD (0.00385 or 0.00392 curve) Large
More informationDissolved Oxygen Measurement liquisys M COM 223 / 253
Technical Information TI 199C/24/ae Dissolved Oxygen Measurement liquisys M COM 223 / 253 Oxygen Controller Benefits at a glance Liquisys M COM 223 Liquisys M COM 253 Due to the modularity of its design,
More informationCDR-AL Room CO 2 Traffic Light Alarm Units and Sensors
Product sheet SN1.402 Type CDR-AL CDR-AL Room CO 2 Traffic Light Alarm Units and Sensors CDR-AL sensors are designed to detect carbon dioxide concentration and temperature in the room spaces. The units
More informationPipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual
MANUAL Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual Model FPT 130 Single Point Freeze Protection Heat Trace Control Table of Contents SCFP-CO-F130 Overview... 3 Installation...
More informationCopying contents of this booklet or handing over to third party is strictly forbidden without written permission from Detector Oy.
Installation manual detector and controller Code no. 20711062 Page 1/30 CONTENTS Controller... 2 Function of the Relays... 2 Gas Detectors... 2 Cabling... 4 Mechanical Installation of the gas detectors...
More informationHYGROMER - MP 400 A Meteorology probe
HYGROMER - MP 400 A Meteorology probe Operating Instructions 1. Introduction With the HYGROMER meteorology probe MP 400A for measuring humidity and temperature, you have purchased a precision measuring
More informationBeck. The differential pressure transmitter for air
Beck. The differential pressure transmitter for air Differential pressure transmitter 984 General description The differential pressure transmitters of the 984 series are used to measure differential pressure,
More informationGASGUARD H 2-1% Hydrogen Sensor OPERATING & INSTALLATION MANUAL
GASGUARD H 2-1% Hydrogen Sensor OPERATING & INSTALLATION MANUAL 2 Table of Contents GasGuard H 2-1% General description. 4 Installation.. 4 Locating the sensor. 4 Installation guidelines 5 Wiring.. 6 Operation..
More informationImprove Performance and Reduce Maintenance Costs. Model Q45D. Dissolved Oxygen Monitor...
Improve Performance and Reduce Maintenance Costs Model Q45D Dissolved Oxygen Monitor... Why Throw Away Money? Why Throw Away Money? ATI s Model Q45D Dissolved Oxygen monitor is designed to provide reliable
More informationNo part of this publication may be reproduced, stored in an automated data file or made public in any form or by any means, whether electronic,
No part of this publication may be reproduced, stored in an automated data file or made public in any form or by any means, whether electronic, mechanical, by photocopying, recording or in any other manner
More informationGas cylinder scale Model GCS-1
Electronic pressure measurement Gas cylinder scale Model GCS-1 WIKA data sheet PE 87.19 Applications Level measurement of liquid gases in gas cabinets and gas distribution systems Level measurement in
More informationSCHMIDT LED Measured Value Display MD Instructions for Use
SCHMIDT LED Measured Value Display MD 10.010 Instructions for Use Table of Contents 1 Important Information... 3 2 Application range... 4 3 Mounting instructions... 4 4 Electrical connection... 6 5 Signalizations...
More informationD-TECT Introduction. Connecting the Unit. Quick Installation. Multi Beam Alignment & Masking. Mounting the Unit
D-TECT 2 GJD300 Quad PIR Movement Detector Package Contents Package Contains: 1 x D-Tect 2 1 x Drilling template for fixing holes 3 x 31.75mm wall plugs 3 x 31.75mm screws 2 x Spare Sliding Curtains 2
More informationSingle Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual
We manage heat MANUAL Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual 1850 N Sheridan Street South Bend, Indiana 46628 (574) 233-1202 or (800) 234-4239
More informationST710-KHJV.03. Wiring diagram. Product description. Temperature controller. Order number
ST71-KHJV.3 Temperature controller Order number 921.8 Wiring diagram Product description The switching outputs of the thermal controller can be programmed as -two-point controller with alarm -three-point
More informationSilicon Pyranometer GSM xx
THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA Instruction for Use 021045/11/09 Silicon Pyranometer GSM 3.3 7.1415.09.0xx ADOLF THIES GmbH & Co. KG Hauptstraße 76 37083
More information0-10 V Wall & Duct Humidistat Installation Instructions
0-10 V Wall & Duct Humidistat Installation Instructions This document covers the operation and installation instructions for the following Nortec Digital Humidistats: Part #: Description: 1510142 0-10
More informationTouchpoint 1. The Touchpoint 1 controller provides 24 hour protection from flammable, toxic or Oxygen gas hazards.
Touchpoint 1 The Touchpoint 1 controller provides 24 hour protection from flammable, toxic or Oxygen gas hazards. Touchpoint 1 controller User Friendly Self-contained, wall mounted enclosure Ultra-clear
More informationUser manual CTX 300 CO 2
User manual CTX 300 CO 2 Analogic CO 2 Gas Detector Part Number: NP300CO2GB Revision: B.0 07/2015 The Fixed Gas Detection Experts Copyright 2016 by Oldham S.A.S. April 2016 All rights reserved. No reproduction
More informationGASGUARD Cl 2. Chlorine Sensor OPERATING & INSTALLATION MANUAL
GASGUARD Cl 2 Chlorine Sensor OPERATING & INSTALLATION MANUAL Operating and Installation Manual 2 Table of Contents GasGuard Cl 2 Operating and Instruction Manual General description. 4 Installation..
More informationHygro Transducer, Hygrothermal Transducer, and CO 2 Measuring Probe for Building Management and Climate Monitoring
Data Sheet 907021 Page 1/9 Hygro Transducer, Hygrothermal Transducer, and CO 2 Measuring Probe for Building Management and Climate Monitoring For measuring relative air humidity, temperature, and fresh
More informationGASGUARD LEL 3 OPERATING & INSTALLATION MANUAL
GASGUARD LEL 3 Ammonia Sensor OPERATING & INSTALLATION MANUAL GasGuard LEL 3 Operating and Installation Manual 2 Table of Contents 3GasGuard LEL Operating and Instruction Manual General description. 4
More informationQPM21 Series Duct CO 2 and Air Quality Sensors
Document No. CE1N1962 QPM21 Series Duct CO 2 and Air Quality Sensors Description Features Application The Carbon Dioxide (CO 2 ) Duct Sensors are directly wired to the controller via twisted pair and/or
More informationCeiling Mount Temperature Sensor
AB-5272 Specifications/Instructions Ceiling Mount Temperature Sensor General Ceiling Mount Temperature Sensor Model TY7301 is a temperature sensor designed to be used with electronic controllers. This
More informationFiber Optic Cable Fence Disturbance Sensor
Architectural & Engineering Specification for Fiber Optic Cable Fence Disturbance Sensor Purpose of document This document is intended to provide performance specifications and operational requirements
More informationGASGUARD NH 3 2% Ammonia Sensor OPERATING & INSTALLATION MANUAL
GASGUARD NH 3 2% Ammonia Sensor OPERATING & INSTALLATION MANUAL 2 Table of Contents GasGuard NH 3 2% General description. 4 Installation.. 4 Locating the sensor. 4 Installation guidelines 5 Wiring.. 6
More informationGASGUARD O 2. Oxygen Sensor OPERATING & INSTALLATION MANUAL
GASGUARD O 2 Oxygen Sensor OPERATING & INSTALLATION MANUAL 2 Table of Contents General description. 4 Installation.. 4 Locating the sensor. 4 Installation guidelines 5 Wiring.. 6 Operation.. 7 Start-up...
More informationCarSense 303 O P E R A T I N G I N S T R U C T I O N S M A G N E T O R E S I T I V E V E H I C L E D E T E C T O R
O P E R A T I N G I N S T R U C T I O N S CarSense 303 TM M A G N E T O R E S I T I V E V E H I C L E D E T E C T O R 4564 Johnston Parkway, Cleveland, Ohio 44128 P. 800 426 9912 F. 216 518 9884 Sales
More informationPRODUCT CONFORMITY CERTIFICATE
PRODUCT CONFORMITY CERTIFICATE This is to certify that the FlowCERT Lite with db3 transducer and remote temperature sensor or db3 transducer with twin Pulsar sun shields using internal temperature compensation
More informationSPECIFICATION SHEET ORGANIC POLLUTION MONITOR. Model: OPM-410A - Organic Pollution Monitor - Issue: OPM-410A-0107-R0 Page 1 ISO ISO-9001
ISO-14001 ISO-9001 SPECIFICATION SHEET ORGANIC POLLUTION MONITOR Model: OPM-410A The Model OPM-410A monitors organic pollution in water from industrial effluent, rivers etc.. The design and construction
More informationIMR 5000 Operating Manual S/N: SAMPLE For information only! IMR Environmental Equipment Inc.
IMR 5000 Operating Manual S/N: For information only! IMR Environmental Equipment Inc. INTRODUCTION 3 SAFETY INSTRUCTIONS 3 SYSTEM DESCRIPTION - IMR 5000 GAS ANALYSIS SYSTEM 4 Function chart IMR 5000 -
More informationOPTISENS TUR 2000 Technical Datasheet
OPTISENS TUR 2000 Technical Datasheet Sensor for turbidity measurement in water and wastewater Rugged design for harsh applications Integrated transmitter with direct 4...20 ma output Near infrared light
More informationModel Gas Alarm Panel APPLICABILITY & EFFECTIVITY. This manual provides instructions for the following Sierra Monitor products:
Model 2102 Gas Alarm Panel APPLICABILITY & EFFECTIVITY This manual provides instructions for the following Sierra Monitor products: Model Description 2102-00 Alarm Panel 2 Channel 2102-01 Alarm Panel 2
More informationD-Tect 2 GJD300 Quad PIR Movement Detector
D-Tect GJD0 Quad PIR Movement Detector Package Contents 3. Package Contains: x D-Tect x Drilling template for fixing holes x Allen Key 3 x 3.75mm wall plugs 3 x 3.75mm screws x Spare Sliding Curtains x
More informationMODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL
TRACON MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL TABLE OF CONTENTS FPT 130 Overview... 2 Installation... 3 Power Source and Load Connections... 4 Temperature Sensor... 5 External
More informationSnifter ATEX22 VERSION. User Manual. Distributor
Snifter ATEX22 VERSION User Manual Distributor Version 1.4 09/09/2009 Table of Contents 1. INTRODUCTION... 3 1.1. Safety... 3 1.2. Product overview... 4 1.3. How does it work?... 4 2. INSTALLATION... 5
More informationSEC 2000 Millenium Infrared Gas Detector
SEC 2000 Millenium Infrared Gas Detector Instruction and Operation Manual Sensor Electronics Corporation 5500 Lincoln Drive Minneapolis, Minnesota 55436 USA (952) 938-9486 Fax (952) 938-9617 Email: sales@sensorelectronic.com
More informationLC2200 Level Controller Installation and Maintenance Instructions
4025250/9 IM-P402-77 AB Issue 9 LC2200 Level Controller Installation and Maintenance Instructions LC2200 ALARM TEST >50% >100%
More informationAppendix A Equipment Used to Monitor Hotels
Appendix A Equipment Used to Monitor Hotels This Appendix describes the data-acquisition equipment that was used in the monitoring phase of the project. Monitoring equipment was used for: Fan-coil and
More informationOilSET-1000 (12 VDC)
Labkotec Oy Myllyhaantie 6 FI-33960 PIRKKALA FINLAND Tel: +358 29 006 260 Fax: +358 29 006 1260 Internet: www.labkotec.fi 20.03.2009 1/11 OilSET-1000 (12 VDC) Oil Separator Alarm Device Copyright 2009
More informationCarSense 303 O P E R A T I N G I N S T R U C T I O N S M A G N E T O R E S I T I V E V E H I C L E D E T E C T O R
O P E R A T I N G I N S T R U C T I O N S CarSense 303 TM M A G N E T O R E S I T I V E V E H I C L E D E T E C T O R 4564 Johnston Parkway, Cleveland, Ohio 44128 P. 800 426 9912 F. 216 518 9884 Sales
More informationSitron s CF Line of Flow Switch Monitors
Sitron s CF Line of Flow Switch Monitors Models: CF 12AC CF 12DC CF 420 F 420 RCF 420 Introduction Sitron s versatile and intelligent line of Thermal Dispersion Flow Switch Monitors are compact switches,
More informationU tube models PTU 09, 12, 15, 25, 30, 35, 40, 45. single linear tube models PTS 09, 12, 15, 25, 30, 35, 40, 45
U tube models PTU 09, 2, 5, 25, 30, 35, 40, 45 & single linear tube models PTS 09, 2, 5, 25, 30, 35, 40, 45 installation, servicing & operating instructions INSTALLATION, SERVICING AND OPERATING INSTRUCTIONS
More informationS304 and S305 Dust Emission Monitors. User Manual. Distributor
S304 and S305 Dust Emission Monitors User Manual Distributor Version 6.4 30/5/2012 Table of Contents 1. INTRODUCTION... 3 1.1 Safety... 3 1.2 Product overview... 4 1.3 Principle of operation... 4 2. INSTALLATION...
More informationGG-R REFRIGERANT SENSOR. Installation and Operation Manual
GG-R REFRIGERANT SENSOR Installation and Operation Manual 2 GG-R Warning Use this product only in the manner described in this manual. If the equipment is used in a manner not specified by Calibration
More informationMark 25 Ultrapure Water Conductivity Analyzer
Martek Instruments, Inc. Mark 25 Ultrapure Water Conductivity Analyzer Instruction Manual WARRANTY POLICY Unless otherwise stated, MARTEK INSTRUMENTS, INC. warrants this equipment to be free from defects
More informationOVEN INDUSTRIES, INC.
OVEN INDUSTRIES, INC. OPERATING MANUAL Model 5C7-252 TEMPERATURE CONTROLLER With PLC Inputs Introduction Thank you for purchasing our controller. The Model 5C7-252 is an exceptionally versatile unit and
More informationOIL FILM DETECTOR (Flame-proof Version) SODL-1600
OIL FILM DETECTOR (Flame-proof Version) SODL-600 The model SODL-600 is a flame-proof type oil film detector. This model monitors a water surface for the presence of an oil film floating on the surface.
More informationLamp Supply (Recommended)
SGX Europe Sp. z o.o. IR600 Datasheet Infrared Gas Sensor for Hazardous Areas (Fixed Systems) The IR600 Series gas sensors are designed to detect and monitor the presence of CO 2, hydrocarbons and acetylene
More informationModel GIT 4 Gutter Snow and Ice Melting Control
We manage heat Model GIT 4 Gutter Snow and Ice Melting Control Part Number 19556 Installation and Operation Manual WARNING Hazard of electrical shock. Follow all safety procedures. Any installation involving
More informationNitrogen Dioxide (NO2) Single-Point Gas Detection System
Nitrogen Dioxide (NO) Single-Point Gas Detection System DESCRIPTION Wall-mounted gas monitor with built-in nitrogen dioxide (NO)/diesel fume gas sensor, accepts one analog remote device such as a secondary
More informationSentry LIQUID LEVEL GAUGE MODEL 200 or 200C OWNER MANUAL REV 1.7 SEPT08 PAGE 1 OF 12
PAGE 1 OF 12 TABLE OF CONTENTS PAGE 1. SAFETY PRECAUTIONS 1.1. Electrical shock 3 2. APPLICATION 3 3. INSTALLATION 3.1. Mount indoor alarm display 3.2. Mount the outdoor junction box 3.3. Install interconnecting
More informationSnifter. User Manual. Distributor
Snifter User Manual Distributor Version 1.3 08/09/2009 1 Table of Contents 1. INTRODUCTION... 3 1.1 Safety... 3 1.2 Product overview... 3 1.3 How does it work?... 3 2. INSTALLATION... 4 2.1 Selecting the
More informationTouchpoint 4. The Touchpoint 4 controller provides protection of personnel and plant from flammable, toxic and Oxygen gas hazards
Touchpoint 4 The Touchpoint 4 controller provides protection of personnel and plant from flammable, toxic and Oxygen gas hazards Touchpoint 4 Controller User Friendly Self-contained, wall mounted enclosure
More informationCLARITY II TURBIDIMETER
Product Data Sheet PDS 71-T1055/rev.J January 2006 Model T1055 CLARITY II TURBIDIMETER COMPLETE SYSTEM includes single or dual input analyzer, sensor(s), and debubbler assembly CHOOSE U.S. EPA METHOD 180.1
More informationModel Q45P/R. ph/orp Monitor...
Model Q45P/R ph/orp Monitor... Sensor Mounting Configurations The Differential Difference ORP Monitor ATI's versatile Q45P/R ph/orp system is designed for use in all industrial and municipal applications.
More informationLong Range Radio Alarm Transmitter
TM Long Range Radio Alarm Transmitter INSTALLATION MANUAL Version 1.3W FEATURES Transmits alarm information to a long range radio network Varitech Transmission Format Note: If automatic SIA is used in
More informationMinimal maintenance requirements - No consumables and low cost of ownership. Rapid, accurate results - for safe operation of coal handling systems
Product Data Sheet CODEL Continuous Mill Fire Detection Coal Mill CO Analyser Low cost, low maintenance devices for continuous monitoring. Robust infrared gas analyser - accurate and reliable operation
More informationOilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor
Labkotec UK Ltd Adminicle House 1 Lumb Lane Audenshaw Manchester M34 5WH GREAT BRITAIN Tel: 0844 3350 477 Fax: 0161 4281 179 E-mail: info@labkotec.co.uk 10.8.2012 Internet: www.labkotec.co.uk 1/13 OilSET-1000
More informationAnalox 1000 Series. User Manual. Analox Sensor Technology Ltd. 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT, UK
Analox 1000 Series User Manual Analox Sensor Technology Ltd. 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT, UK T: +44 (0)1642 711400 F: +44 (0)1642 713900 W: www.analox.net E: info@analox.net
More informationOilSET Installation and Operating Instructions. Oil Separator Alarm Device
Labkotec Oy Myllyhaantie 6 FI-33960 PIRKKALA FINLAND Tel: +358 29 006 260 Fax: +358 29 006 1260 18.11.2010 Internet: www.labkotec.fi 1/10 OilSET-1000 Oil Separator Alarm Device Copyright 2010 Labkotec
More informationIntegrated Sensor Suite Installation Manual
Integrated Sensor Suite Installation Manual for Vantage Pro Weather Stations Product # 6320, 6320C, 6321, 6321C, 6325, 6325C, 6326, 6326C Contents Introduction........................................................
More informationInstructions for the fan motor control system with integrated wiring terminals SILVER C
Instructions for the fan motor control system with integrated wiring terminals SILVER C 1. General The motor control system is used for controlling the type EC, 0.41-10 kw fan motors in the SILVER C units.
More informationSieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required
Sieger Sensepoint The Sensepoint range of flammable, toxic and oxygen gas detectors offer users a high quality, low cost solution to their industrial gas monitoring needs. Sieger Sensepoint Fit For Purpose
More informationIRtech. E instruments. IRtech Radiamatic IR20 LS series. Infrared Technology
E instruments IRtech Temperature range up to 2200 C Optical resolution up to 300:1 Close focus 0,5mm 8-14µm, 1.6µm, 1µm, 2.3µm, 3.9µm, 4.2µm, 4.6µm, 5.1µm and 7.9µm Spectral response Dual laser true target
More informationRK CO 2 Transmitter Operator s Manual
65-2397RK CO 2 Transmitter Operator s Manual Part Number: 71-0185RK Revision: B Released: 7/18/14 RKI Instruments, Inc. www.rkiinstruments.com WARNING Read and understand this instruction manual before
More informationSMART Gas Detector/Transmitter(4~20mA) with built-in LCD & explosion proof DA-500
SMART Gas Detector/Transmitter(4~20mA) with built-in LCD & explosion proof DA-500 C-910C, Bupyeong Woolim Lion s Valley, #425, Cheongcheon-Dong, Bupyeong-Gu, Incheon, Korea TEL: +82-32-623-7507 FAX: +82-32-623-7510
More informationUnipoint Controller. The Unipoint, a simple DIN rail mounted controller
Unipoint ontroller The Unipoint, a simple DIN rail mounted controller Unipoint DIN ontroller Typical Applications Small and medium integrated systems ustom control cabinets and panels Unmanned equipment
More informationUnipoint controller. The Unipoint, a simple DIN rail mounted controller
Unipoint controller The Unipoint, a simple DIN rail mounted controller Unipoint DIN controller Typical Applications Small and medium integrated systems ustom control cabinets and panels Unmanned equipment
More information02/11/2015
CTH 46 - CTD 43 / 46 CTD 46 Part number 89422108 CTH 46 Heating / cooling function Measurement and setpoint display CTD 43 Heating or cooling function Measurement display Measurement deviation display-setpoint
More informationMODEL 4000A & 4001A ACCELEROMETER
MODEL 4000A & 4001A ACCELEROMETER dimensions 4001A Connector Attachment SPECIFICATIONS Silicone MEMS Accelerometer Signal Conditioned Output Temperature Calibrated Low Cost, Lightweight The Model 4000A
More informationVentostat Wall Mount. Amphenol. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. Advanced Sensors. Features:
Ventostat Wall Mount Telaire Wall Mount, Humidity and Temperature Transmitters Features: Patented, Absorption Infrared Gas sensing engine provides high accuracy in a compact low cost package. Patented
More informationRE-PR3-E-27 3-Phase Panel Mount 27kW
Page 1 of 6 RE-PR3-E-27 3-Phase Panel Mount 27kW Features: Benefits: 0-10Vdc, 0-5Vdc, 4-20mA or manual via potentiometer control input Over temperature protection with auto reset Enclosed panel mounting
More informationInfrared Temperature Sensor
Infrared Temperature Sensor With High Speed Sensor, Small Measured Spot and Continuous LED Sighting OS-PC Series U High Speed Cube Sensor with Optional Touch Screen Display U Response Time 0.001 Seconds
More informationTox-COMB/ANA Combustible Gas Transmitter Operator s Manual
Tox-COMB/ANA Combustible Gas Transmitter Operator s Manual Part Number: 71-0132TA Revision: A Released: 4/23/10 www.toxalert.com Product Warranty Toxalert International, Inc. warrants gas alarm equipment
More informationGAS MONITOR Model Model
Sierra Monitor Corporation 1991 Tarob Court, Milpitas, CA 95035 (408) 262-6611 (800) 727-4377 (408) 262-9042 - Fax E-mail: sierra@sierramonitor.com Web Site: www.sierramonitor.com GAS MONITOR Model 2350-00
More informationOIL FILM DETECTOR (Long-distance correspondence Version)
OIL FILM DETECTOR (Long-distance correspondence Version) ODL-6A The Model ODL-6A monitors a water surface for the presence of an oil film floating on the surface. The instrument projects a laser beam onto
More informationGG-NH3-2% AMMONIA GAS SENSOR. Installation and Operation Manual
GG-NH3-2% AMMONIA GAS SENSOR Installation and Operation Manual 2 GG-NH3-2% Warning Use this product only in the manner described in this manual. If the equipment is used in a manner not specified by Calibration
More informationLaser Distance Sensor Type M Analog-Output
Laser Distance Sensor Type M Analog-Output Operating Manual Version 2.3, May 2009 ELAG Elektronik AG l Stegackerstrasse 14 l CH-8409 Winterthur Contents 1. Safety 1.1 Laser safety 1.2 Electrical safety
More informationMultifunction IAQ Monitor
Multifunction IAQ Monitor Better Sensing, Better Life Introduction The standard monitor has below two models Carbon dioxide(co 2)+CO 2 average +Temperature+ Humidity (Model:DPM-1003) Carbon dioxide(co
More informationGG-EM ENTRANCE MONITOR. Installation and Operation Manual
GG-EM ENTRANCE MONITOR Installation and Operation Manual 2 GG-EM Warning Use this product only in the manner described in this manual. If the equipment is used in a manner not specified by Calibration
More information