Sapphire ULTRASONIC POINT LEVEL SYSTEM

Size: px
Start display at page:

Download "Sapphire ULTRASONIC POINT LEVEL SYSTEM"

Transcription

1 ULTRASONIC POINT LEVEL SYSTEM Introduction Compliance with growing government regulations mandates tighter level controls with advanced diagnostics to avoid releases, overspills and costly environmental clean-ups. Using anything but the most reliable and dependable point level switch for high level alarms and spill prevention has become unacceptable. Advancements in acoustical design and materials combined with Sapphire s patented Time-Gate technology have produced the most reliable and technically advanced level switch of its type. Sapphire performs exceptionally well in aerated, attenuative, viscous, corrosive, and even more severe applications. From the originators of the ultrasonic point level Gap switch technology, Sapphire is the industry standard for reliable point level measurements. Thermo took 30 years of level experience and developed Sapphire s unique measurement technique with superior selftesting capabilities. The continuous self-test feature automatically checks system integrity including electronics, sensor, and crystal disbonding, without the need for additional crystals or sensors mounted electronics. Sapphire s dual compartment housing provides quick and easy access to field wiring connections while protecting the electronics from exposure to harsh environments, damage, or leaky connections. During system installaion, electronics do not require removal and are safely protected while pulling wire and making field terminations. Sapphire systems carry Factory Mutual Research Corp. (FMRC) and Canadian Standars Asso. (CSA) approvals including Features & Benefits Single & Dual Point Systems Unmatched Reliability Superior Self-Testing Capabilities Variable System Qualification Time New Manual Loop Test Dual-compartment Housing (Single Point) Lowest Total Installed Cost Broad Range of Sensor Materials Broader Hazardous Location Approvals 3A Sanitary Finish and Fittings Dual Point Switch with completely independent electronics Dual point with up to 10 ft. or more separation Two Year Product Warranty NEMA 4X, intrinsically safe, explosion-proof, nonincendive, and dust/ignition-proof ratings. Installation and life cycle costs are reduced significantly with the use of loop powered intrinsically-safe outputs, elimination of poured seals at the electronics in Division 1 areas and elimination of rigid conduit and poured seals in Division 2 areas.

2 Time Gate Technology Time Gate Technology starts by activating a transit crystal on one side of the measurement Gap and listening with a receive crystal on the opposite side. Since high frequencies of ultrasound travel readily through fluids but not air, liquid presence is determined by ultrasonic transmission within the measurement Gap. The signals from the receive crystal are analyzed at specific time intervals or windows controlled by the Time Gate. This method raises the system s sensitivity beyond the capabilities of previously available systems. Sapphire s patented Time Gate technology provides two important user benefits: 1. Reliable detection of the broadest possible range of process liquids including aerated, attentuative, viscous, corrosive, and more severe applications. 2. Self-tests are performed continuously and automatically. Sappire systems are available in either Gap or Slot configuration. Gap sensors perform exceptionally well in most applications, including aerated and attenuative liquids. The Slot s higher sensitivity provides reliable operation in even more severe applications. Continuous Self-Test Time Gate technology also incorporates a unique selftest function which it performed continuously and automatically. It verifies the system integrity including electronics, sensor and the crystal bond to the sensor body. Sapphire s self-test design does not involve the use of special self-test crystals or electronics inside the sensor probe. The simpler selftest design and the unique ability to detect disbonded crystals raises the level of Sapphire s dependability and reliability. System Qualification Time The System Qualification Time is the amout of time that process liquid must be continuously present or absent within the measurement Gap (in high-level operation) before the process alarm will be indicated. Sapphire qualifies that the new level condition is continuously present instead of a momentary occurence. This assures that the actual liquid level has reached the measurement Gap, instead of a wave fluctuation due to agitation or turbulence. Manual Loop Test The use of spill prevention devices such as Sapphire for high level alarms is on the rise. There are a number of environmental regulations that govern the overfill protection of above ground storage tanks (e.g., EPA, API, OSHA, etc.). In many cases, these regulations require written testing procedures, automatic verification, and on-demand testing of the complete spill prevention system. The Manual Loop Test is standard to verify field wiring, control integrity and operation of spill prevention systems without the need for filling tanks or costly system removal for testing. Manual Loop Test will change the outputs to the opposite state when the systems is not in the self-test or fault condition. The Manual Loop Test is momentarily activated as long as the supplied magnet is placed over the housing cover at the location marked Loop Test Materials and Mounting Gap sensors are available in a broad range of materials which include 316 stainless steel, Hastelloy C, Monel, Hastelloy B and Carpenter20. Slot sensors are available in 316 stainless steel only. Both the Gap and the Slot sensors can be delivered with a 150 grit (32 micro inch) or better, sanitary 3A finish and 316L stainless steel Tri-Clover (16 AMP) fittings that assemble and disassemble quickly for fast cleaning. Sapphire is the only ultrasonic point level system available with 3A symbol authorization. Sapphire systems are available with either 3/4 NPT mounting, various flange sizes, Tri-Clover fittings, or remotely mounted electronics. Sapphire Relay Operation The Sapphire relay models provide one Process relay for process level indication and a second Auxiliary relay for self-test fault indicationn. Both relays utilize gold plated contacts for reliable switching of lower current and voltage levels eliminating the need for DCS users to install interposing relays. Sapphire systems can be field selected for either high-level or low-level fail-safe operation. When high-level operation is selected, the Process relay is energized when the sensor is dry and de-energized when wet (e.g. in alarm). When low-level operation is selected, the Process relay is energized when the sensor is wet and de-energized when dry (e.g. in alarm). In both cases, the Process relay is always deenergized upon process alarm, self-test fault or power loss. The Auxiliary relay always de-energizes on self-test fault or power loss. The Auxiliary relay can be field selected to mimic the Process relay. When Mimic is selected, the Auxiliary relay will de-energize when a

3 In addition, the SPST Auxiliary relay output is field selectable for either NC or NO operation. Performance Specifications - Relay Operation Supply Voltage: VDC (Electronics Model F) 115 VAC, ±10%, 50/60 Hz (Model G) 230 VAC, ±10%, 50/60 Hz (Model S) Power Consumption: 4 Watts maximum (2 Watts typical) Process Relay: SPDT relay with gold plated contacts. De-energizes on process alarm, self-test or power loss Maximum contact rating: 5 Amps at 115/250 VAC or 5 Amps at 30 VDC Minimum contact rating: 100 ma at 5 VDC or 15 ma at 24 VDC Auxiliary Relay: SPST (field selectable for either NC or NO operation) relay with gold plated contacts. De-energizes on selftest, power loss (and process alarm when mimic operation is field selected). Maximum contact rating: 5 Amps at 115/250 VAC or 5 Amps at 30 VDC Minimum contact rating: 100 ma at 5 VDC or 15 ma at 24 VDC Sapphire Two-Wire Operation The Sapphire two-wire, 4-20 ma DC model provides loop powered intrinsically-safe operation and lower installed costs to users with two-wire instrumentation. Two-wire systems use a fixed milliamp output to indicate process level (wet or dry sensor) and self-test fault. The wet and dry conditions can be indicated with either an 8 or 16 ma DC output. A self-test fault is indicated by an output of either 19 or 5 ma DC, depending on whether field selected for high-level or low-level operation, respectively. Performance Specifications - Two-Wire Operation: Supply Voltage: VDC (Model J) Power Consumption: 1.1 Watt maximum Analog Ouput (±1 ma) 5 ma Self-Test Fault (low-level mode) 8 ma Dry, 16 ma Wet (field-selectable) 8 ma Wet, 16 ma Dry (field-selectable) 19 ma Self-Test Fault (high-level mode) Sapphire Relay and Two wire Operating Specifications Self-Test Feature Continuous. Automatically checks operation of electronics and sensor, including crystal bond to sensor body. Manual Loop Test: All output conditions momentarily change to the opposite state (except when in a fault condition) by placing the supplied magnet (XB4353) over the housing covers at the location marked Loop Test. System Qualification Time: 0.3 to 12.0 seconds, field selectable Repeatability: ±0.1 inches Enclosure Dual-compartmetn NEMA 4X (ANSI 250 Type 4X) Enclosure 4 housing. Low copper aluminum; Polyurethane paint; Buna-N O-rings. Electrical Connections: Dual 1/2-inch NPT conduit connections. Wire range is 22 to 12 AWG. Operating Temperature Range: Electronics: -40 to 158 F (-40 to 70 C) Metal Sensors: -40 to 320 F (-40 to 160 C) -310 to 212 F (-190 to 100 C) Humidity: RH, non-condensing Weight (with 3/4 NPT, 1.0 inch A dimension): 4 lbs. (1.8 Kg) Current Loop Loads: Rload, max = (V supply-12) x 50 Ohms

4 SAPPHIRE ENCLOSURE DIMENSIONS 4.25 (108.0) 4.10 (104.1) STAINLESS STEEL CUSTOMER TAG (OPTIONAL) 1/2 NPT (2 PLACES) 0.69 (17.5) Place Loop Test Magnet Here 6.60 (167.6) NOTE 2 CONNECTION SIDE 6.15 (156.2) APPROVAL LABEL (IF APPLICABLE) PRODUCT IDENTIFICATION LABEL Circuit Side NOTES: 1. Dimensions are in inches (millimeters), nominal, and are for reference only. 2. Dimensions increase in 3 inches (76.2 mm) with installation of optional thermal isolator (3/4 NPT fitting only). SAPPHIRE SENSOR DIMENSIONS STANDARD GAP SENSOR STANDARD SLOT SENSOR TRI-CLOVER GAP SENSOR A DIMENSION A DIMENSION A DIMENSION 1.44 (36.6) 2.75 (69.9) 1.44 (36.6) 0.88 (22.4) DIA 0.94 (23.9) 0.88 (22.4) DIA 0.30 (7.6) 0.88 (22.4) DIA 0.94 (23.9) NOTES: 1. Dimensions are in inches (millimeters), nominal, and are for reference only. 2. Dotted lines represent optional fitting & flange types. 3. Total sensor length is equal to the A Dimensions plus the remaining sensor length.

5 Factory Mutual (FM & Canadian Standards Association (CSA) Approved): Explosion Proof: Class I, Division 1, Groups B (FMRC only ), C, & D Intrinsically Safe (Entity) Class I, Division 1, Groups A, B, C, & D. T4 Temperature cods (135 C) when installed in accordance with I/S wiring diagram of Instruction Manual, section 4, page 4-4. Entity parameters: Vmax = 55V, Imax = 118 ma, Ci = 0.024uF, Li = 0 mh. Dust/Ignition Proof: Class II, Division 2, Groups E, F, & G Class III, Hazardous Locations Sensor Style Gap Non-incendive: Class I, Division 2, Groups A, B, C, & D. T4A Temperature Code (120 C) Suitable for Class II, Groups E & G. Suitable for Class III, Hazardous Locations Remote sensor and field wiring are approved as N/I field wiring when installed in accordance with Class I, Division 2 wiring diagram of Instruction Manual Indoor/Outdoor Use: NEMA 4X (ANSI 250 Type 4X) Enclosure 4 Stainless Steel Tagging Each Sapphire can be labeled with up to 15 characters of user-specified 1/16 text located on the product s identification label. An optional stainless steel tag (part # ), located on top of the electronics housing, can provide four lines of 1/8 text (two lines for remote systems) with a maximum of 24 characters per line. Slot Materials of Construction Carpenter 20 Hastelloy C Monel Hastelloy B 316SS 316 SS Min. Sensor A Dimension 1 inch (25 mm) 4 inches (102mm) Max. Sensor A Dimension Remaining Sensor Length Sensor Operating Temperature 1 Maximum Operating Pressure 2 Proof Pressure inches (3,048 mm) 1.44 inches (36.6 mm) -40 to 320 F (-40 to 160 C) -310 to 212 F (-69 to 100 C) -10 to 1,000 psig (-69 to 6,895 KPa) 1,500 psig (10,342 KPa) 120 inches (3,048 mm) 0.30 inches (7.6 mm) -40 to 320 F (-40 to 160 C) -310 to 212 F (-190 to 100 C) -10 to 1,000 psig (-69 to 6,895 KPa) 1,500 psgi (10,342 KPa) NOTES 1. The Thermal Isolator is required for 3/4 NPT unit when process temperatures exceed 275 F (135 C). Flanged and remote mounted units do not require the use of the Thermal Isolator. 2. Pressure ratings are for 3/4 NPT units. NOTES 1. Order in 5/10 inch or 10 millimeter increments, because manufacturing tolerances are ±2/10 inch (±5 mm) for metal sensors. 2. When specifiying sensor lengths, be sure to take into consideration that the total installed sensor length is equal to the A dimension plus the remaining sensor length. 3. Tri-Clover fittings are available with integral mounted Sapphire systems only; Tri-Clover fittings are not available with remote mounted systems. A 1 Tri-Clover is the same size as a 1-1/2 Tri-Clover fitting.

6 SAPPHIRE INTEGRAL MOUNT PRODUCT NOMENCLATURE SASP Code F C Hazardous Location Approvals Factory Mutual Approved Canadian Standards Association Code Electronics J VDC Input, 4-20mA Intrinsically Safe Output F VDC Input, Relay Output, NO or NC User-selectable Auxiliary Fault Relay G 115 VAC Input, Relay Output, NO or NC User-selectable Auxiliary Fault Relay S 230 VAC Input, Relay Output, NO or NC User-selectable Auxiliary Fault Relay Code Mounting Configuration O Integral Electronics and Sensor T Thermal Isolator (Required for 3/4" NPT units with process temperatures above 275 F/ 135 C) Code Sensor Type G Gap S Slot (316SS, 316SS Polished & Hastelloy C) Code Sensor Material (Same as Fitting/Flange Material) (See Sapphire Ref Note 1) S V H U B Q 316 Stainless Steel (Gap & Slot) 316 Polished Stainless Steel (Gap & Slot) Hastelloy C (Gap & Slot) Monel (Gap only) Hastelloy B (Gap only) Carpenter 20 (Gap only) Code Measurement Units for "A" Dimensions T M Sapphire Inches Millimeters Code Sensor "A" Dimension (See Sapphire Ref Note 3 & 4) 0##0 Sensors are available in 0.5" increments only 316 SS for Gap Sensors (Minimum 1") (0010 = 1.0") 316 SS/pol'd for Slot Sensors (Minimum 4") (1200 = 120.0") Hastelloy C 0##0 Sensors are available in 5mm increments only Monel for Gap Sensors (Minimum 25mm) (0025 = 25mm) Hastelloy B for Slot Sensors (Minimum 100mm) (3050 = 3050mm) Carpenter20 Code Fitting/Flange Type (See Sapphire Ref Note 1 & 2) N 3/4" NPT (Material same as sensor) F Flange 150 lb. ANSI Raised Face (Metal) G Flange 300 lb. ANSI Raised Face (Metal) T Tri-Clover (16 AMP) Sanitary Fitting & 150 Grit Polished Code Fitting/Flange Size (See Sapphire Ref Note 2) 00 3/4" NPT 10 1" Flange or Tri-Clover Fitting /2" Flange or Tri-Clover Fitting 20 2" Flange or Tri-Clover Fitting /2" Tri-Clover Fitting Only 30 3" Flange or Tri-Clover Fitting 40 4" Flange or Tri-Clover Fitting 60 6" Flange Only Code Fitting/Flange Material (Same as Sensor) S 316 SS V 316 Polished SS (Tri-Clover 3A & 3/4" NPT Only) H Hastelloy C U Monel B Hastelloy B Q Carpenter 20 Code Accessories (Optional) T Stainless Steel Tag (Cust Reqst) SASP F G O G S T 0060 N 00 S Typical Integral System Part Number /01 Sugar Land 1410 Gillingham Lane Sugar Land, Texas (v) (f) Canada 14 Gormley Industrial Avenue, Unit 14 Gormley, Ontario LOH 1G (v) (f) sales.process@thermo.com Winsford Ion Path, Road Three, Winsford Cheshire UK CW7 3GA +44 (0) (v) +44 (0) (f)

Sensall Sapphire. Thermo MeasureTech ULTRASONIC POINT LEVEL SYSTEM

Sensall Sapphire. Thermo MeasureTech ULTRASONIC POINT LEVEL SYSTEM ULTRASONIC POINT LEVEL SYSTEM Introduction Compliance with growing government regulations mandates tighter level controls with advanced diagnostics to avoid releases, overspills and costly environmental

More information

Sapphire. Ultrasonic Point Level System User Guide P/N Part of Thermo Fisher Scientific. Revision C

Sapphire. Ultrasonic Point Level System User Guide P/N Part of Thermo Fisher Scientific. Revision C Sapphire Ultrasonic Point Level System User Guide P/N 900-000068 Revision C Part of Thermo Fisher Scientific Sapphire Ultrasonic Point Level System User Guide P/N 900-000068 Revision C 1992 Thermo Fisher

More information

Ultrasonic Point Level Switches

Ultrasonic Point Level Switches see more at SORInc.com Request Quote Ultrasonic Point Level Switches Ultrasonic point level switches are a cost-effective solution for your applications. Installation requires mounting the sensor (threaded

More information

Ultrasonic Switches. Features & Benefits

Ultrasonic Switches. Features & Benefits Why use an ultrasonic switch over other level technologies? Depending upon your application, there may be three or four technologies equally suited for your application; however; only one will be the best

More information

Brooks MT3600 Series Metal Tube Variable Area Flowmeters

Brooks MT3600 Series Metal Tube Variable Area Flowmeters Data Sheet Flanged, NPT or socket-welded connections 10% full scale accuracy Disassembly for cleaning without removal from the process line Standard direct reading, detachable scales Permanent magnetic

More information

Electronic Flow Switches

Electronic Flow Switches Industries Electronic Flow Switches Petrochemical Refining Oil Production Water Treatment Pharmaceutical Food and Beverage Pulp and Paper Power Production Gas Processing Mining Biotechnology Semiconductor

More information

Glass Tube Variable Area Flowmeter

Glass Tube Variable Area Flowmeter GT 1000 Series Models 1020, 1024, 1026, 1027 Design Specifications DS-GT 1000 April, 1997 (Supersedes issue dated December, 1996) Glass Tube Variable Area Flowmeter Wide choice of application-specific

More information

Installation and Operating Instructions

Installation and Operating Instructions The Leader of RF and Sonic Level For Assistance Call 1-800-527-6297 Outside North America 1-215-674-1234 Installation and Operating Instructions Series 504-1200 Ultrasonic VeriGAP Switch using 404-1200

More information

High Pressure Conductivity Monitor

High Pressure Conductivity Monitor Product Data Sheet PDS 71-EDS880/1/rev.A August 2006 Model EDS880/1 High Pressure Conductivity Monitor COMPLETE SYSTEM FOR THE DETERMINATION OF CONDUCTIVITY IN HIGH PRESSURE SYSTEMS SENSOR INSTALLS DIRECTLY

More information

E C H O T E L C O N T A C T U L T R A S O U N D

E C H O T E L C O N T A C T U L T R A S O U N D E C H O T E L C O N T A C T U L T R A S O U N D Contact Ultrasonic Level Sensing FROM Ultrasound technology was developed during the amplifier becomes as oscillator causing a relay WWII under the acronym

More information

ECHOTEL 961/962. Ultrasonic level switches. Worldwide level and flow solutions DESCRIPTION. Loop or line powered FEATURES AGENCY APPROVALS

ECHOTEL 961/962. Ultrasonic level switches. Worldwide level and flow solutions DESCRIPTION. Loop or line powered FEATURES AGENCY APPROVALS ECHOTEL 961/962 Ultrasonic level switches DESCRIPTION The Echotel 961/962 series utilizes pulse signal technology to detect high or low level alarm(s) in a broad range of viscous to light liquids. Pulsed

More information

ABB MEASUREMENT & ANALY TICS DATA SHEET. RS85 Vibrating fork level switch

ABB MEASUREMENT & ANALY TICS DATA SHEET. RS85 Vibrating fork level switch ABB MEASUREMENT & ANALY TICS DATA SHEET RS85 Vibrating fork level switch 2 RS 8 5 VI BR ATI N G FOR KL EVEL SW ITC H DS/RS8 5-E N RE V. S Measurement made easy Multi option liquid level switch K TEK Level

More information

Sanitary Pressure Transmitter

Sanitary Pressure Transmitter Product Data Sheet 00813-0100-4698 Sanitary Pressure Transmitter A TRADITION OF EXCELLENCE IN PERFORMANCE Absolute or gage pressure ranges from 0 3 to 0 800 psi 0.20% reference accuracy, including linearity,

More information

Metal Tube Variable Area Flowmeter with Optional Electronics based on Smart Meter Manager Technology

Metal Tube Variable Area Flowmeter with Optional Electronics based on Smart Meter Manager Technology Data Sheet Brooks Model MT 3810 Metal Tube Variable Area Flowmeter with Optional Electronics based on Smart Meter Manager Technology GENERAL FEATURES Broad range of flow capacities 5% Full scale accuracy

More information

Brooks Models MT 3809 and 3819 Metal Tube Variable Area Flowmeters with Optional Electronics based on Smart Meter Manager TM Technology

Brooks Models MT 3809 and 3819 Metal Tube Variable Area Flowmeters with Optional Electronics based on Smart Meter Manager TM Technology Data Sheet Models MT 3809 & 3819 Brooks Models MT 3809 and 3819 Metal Tube Variable Area Flowmeters with Optional Electronics based on Smart Meter Manager TM Technology Broad range of flow capacities 2%

More information

Ramsey Series Motion Monitoring Systems Accurate Sensing of Speed Conditions on Rotating Shafts and Machinery

Ramsey Series Motion Monitoring Systems Accurate Sensing of Speed Conditions on Rotating Shafts and Machinery Ramsey Series 60-200 Motion Monitoring Systems Accurate Sensing of Speed Conditions on Rotating Shafts and Machinery Ramsey Series 60-200 Motion Monitoring Systems offer versatile and reliable packages

More information

VIBRATION TRANSMITTER MODEL 140T INSTALLATION The mounting orientation can be in any position. This position should be in an area for the best vibrati

VIBRATION TRANSMITTER MODEL 140T INSTALLATION The mounting orientation can be in any position. This position should be in an area for the best vibrati VIBRATION TRANSMITTER MODEL 140T A lowcost, yet highly accurate and rugged vibration transmitter, the Model 140T is ideal for use with all machines, even those which previously may have been considered

More information

Enraf Servo Gauge 854 ATG

Enraf Servo Gauge 854 ATG Enraf Servo Gauge 854 ATG Setting the standard in gauging. From the company that pioneered development of modern tank gauges, Honeywell s 854 Automatic Tank Gauge has become an industry standard all over

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Certificate: 1655492 (219995) Issued to: R.C. Systems Co., Inc. 8621 Hwy 6 Hitchcock, Texas 77563 USA Attention: Roger Carter The products listed below are eligible to bear the

More information

Annubar Flowmeter Series

Annubar Flowmeter Series Reference Manual Appendix B Approvals Annubar Flowmeter Series Hazardous Locations Installations.................. page B-1 Rosemount 3051SFA Product Certifications.......... page B-1 Rosemount 3095MFA

More information

Enraf Servo Gauge 854 XTG

Enraf Servo Gauge 854 XTG Enraf Servo Gauge 854 XTG Cut costs, not repeatability. Honeywell s 854 XTG servo gauge is a high performance alternative to other tank level measurement technologies such as radar tank level gauges. It

More information

Rosemount 752 Fieldbus Remote Indicator

Rosemount 752 Fieldbus Remote Indicator Product Data Sheet Rosemount 752 Rosemount 752 Fieldbus Remote Indicator ROSEMOUNT 752 DELIVERS: Two-wire segment powered device Displays up to 8 values Link Master Capability Optional PID, Characterizer,

More information

Rosemount 2090F Hygienic Pressure Transmitter

Rosemount 2090F Hygienic Pressure Transmitter Hygienic Pressure Transmitter Conforms to 3-A Sanitary s Features CIP/SIP service for process temperatures up to 284 F (140 C) Absolute or gage pressure ranges from 0-1.5 to 0-300 psi Mounts with either

More information

AM54. Armored Variable Area Flowmeter Series AM54331/32 Series AM54371/72/73/74 Series AM54431/32 Series AM54471/72/73/74

AM54. Armored Variable Area Flowmeter Series AM54331/32 Series AM54371/72/73/74 Series AM54431/32 Series AM54471/72/73/74 AM54 Instruction Bulletin North American Installation Addendum Document Number PN25016 Armored Variable Area Flowmeter Series AM54331/32 Series AM54371/72/73/74 Series AM54431/32 Series AM54471/72/73/74

More information

Sitron s CF Line of Flow Switch Monitors

Sitron s CF Line of Flow Switch Monitors Sitron s CF Line of Flow Switch Monitors Models: CF 12AC CF 12DC CF 420 F 420 RCF 420 Introduction Sitron s versatile and intelligent line of Thermal Dispersion Flow Switch Monitors are compact switches,

More information

ULTRA-SAFE Explosion-proof Duct Heaters

ULTRA-SAFE Explosion-proof Duct Heaters Standard Construction Heat Exchanger has copper tubes with integral aluminum fins. Each unit undergoes hydrostatic testing at 350 psig, five times the pressure relief valve setting of 70 psig. Heat Transfer

More information

Rosemount 2090F Sanitary Pressure Transmitter with HART Protocol

Rosemount 2090F Sanitary Pressure Transmitter with HART Protocol Sanitary Pressure Transmitter with HART Protocol A TRADITION OF EXCELLENCE IN PERFORMANCE Conforms to 3-A Sanitary Standards Features CIP/SIP service with an upper temperature limit of 284 F (140 C) USDA

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Certificate: 1563164 Issued to: Metal Samples Company, A Div. of Alabama Specialty Products, Inc. 152 Metal Samples Rd PO Box 8 Munford, Alabama 36268 USA Attention: Bala Palanisamy

More information

Ar-Mite TM Low Flow Armored Flowmeter

Ar-Mite TM Low Flow Armored Flowmeter Data Sheet Brooks Ar-Mite TM MT 3750C Ar-Mite TM Low Flow Armored Flowmeter Ar-Mite TM Model MT 3750 Metal Tube Flowmeter Ar-Mite TM Model MT 3750 Metal Tube Flowmeter with Transmitter or Inductive Alarm

More information

Series 155. Mass Flow Computers TECHNICAL SPECIFICATIONS

Series 155. Mass Flow Computers TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS Mass Flow Computers Series 155 The Kurz 155 Mass Flow Computer is a versatile system transmitter that integrates the functions of flow and temperature measurement, flow totalization,

More information

"ESDDR" Series Electric Humidifier

ESDDR Series Electric Humidifier ESDDR-1 Deionized, Demineralized, or Reverse Osmosis Water "ESDDR" Series Electric Humidifier The Electric Humidifier from PURE Humidifier Co. is loaded with features and options. All you need is deionized,

More information

Instruction Manual Model A

Instruction Manual Model A 706 Bostwick Avenue, Bridgeport, CT 06605 TEL: 203-368-6751 FAX: 203-368-3747 1-800-566-6822 www.devarinc.com Instruction Manual Model 18-232A LOOP POWERED ALARM MANUAL NO. 990029 MODEL 18-232A LOOP POWERED

More information

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS FOR PIPE THREAD IMMERSION HEATERS USED IN HAZARDOUS LOCATIONS

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS FOR PIPE THREAD IMMERSION HEATERS USED IN HAZARDOUS LOCATIONS INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS FOR PIPE THREAD IMMERSION HEATERS USED IN HAZARDOUS LOCATIONS I. GENERAL Heatrex Explosion-proof Pipe Thread Mounted Immersion Heaters are CSA approved

More information

Rosemount 3100 Series Ultrasonic Level Transmitters

Rosemount 3100 Series Ultrasonic Level Transmitters Product Data Sheet Ultrasonic Level Transmitters Non-contacting measurement with no moving parts Integral LCD and push-buttons as standard for on-site programming Continuous measurement of level or distance-to-surface.

More information

Rosemount 3095MFC Compact Orifice Mass Flowmeter

Rosemount 3095MFC Compact Orifice Mass Flowmeter Rosemount 3095MFC Compact Orifice Mass Flowmeter SPECIFICATIONS Performance System Reference Accuracy Percent (%) of mass flow rate TABLE 11. 3095MFC Compact Orifice Mass Flowmeter TYPE Repeatability ±0.1%

More information

ROYCE SUSPENDED SOLIDS SYSTEM MODEL 7011A AND SENSORS MODELS 72A, 72P, 73B, 74A, 75A & 76A

ROYCE SUSPENDED SOLIDS SYSTEM MODEL 7011A AND SENSORS MODELS 72A, 72P, 73B, 74A, 75A & 76A SPECIFICATIONS (Revised 1/12/2006) ROYCE SUSPENDED SOLIDS SYSTEM MODEL 7011A AND SENSORS MODELS 72A, 72P, 73B, 74A, 75A & 76A The system shall operate on the principle of light absorption. It shall consist

More information

TABLE OF CONTENTS Flow Detect 1000 Specifications 3 Description 4 Principle of Operation 4 Detection Through Walls 4 Sensing Beam Shape 4 Installation

TABLE OF CONTENTS Flow Detect 1000 Specifications 3 Description 4 Principle of Operation 4 Detection Through Walls 4 Sensing Beam Shape 4 Installation DETECT 1000 DOPPLER DETECTION INSTALLATION AND OPERATING INSTRUCTIONS READ THOROUGHLY BEFORE INSTALLING EQUIPMENT TABLE OF CONTENTS Flow Detect 1000 Specifications 3 Description 4 Principle of Operation

More information

CLARITY II TURBIDIMETER

CLARITY II TURBIDIMETER Product Data Sheet PDS 71-T1055/rev.J January 2006 Model T1055 CLARITY II TURBIDIMETER COMPLETE SYSTEM includes single or dual input analyzer, sensor(s), and debubbler assembly CHOOSE U.S. EPA METHOD 180.1

More information

Rosemount 4500 Hygienic Pressure Transmitter. Start

Rosemount 4500 Hygienic Pressure Transmitter. Start Quick Installation Guide June 2007 Rosemount 4500 Rosemount 4500 Hygienic Pressure Transmitter ProductDiscontinued Start Step 1: Mount the Transmitter Step 2: Set the Switches Step 3: Connect Wiring and

More information

Certificate of Compliance

Certificate of Compliance FF0002 Certificate of Compliance Certificate: 2792948 Issued to: Siemens Canada Limited 1954 Technology Drive Peterborough, ON K9J 7B1 Canada Attention: Mr. Lee Rogers The products listed below are eligible

More information

UW Purchase Specification Section Steam Condensate or Hot Water Meter Page 1 of 9

UW Purchase Specification Section Steam Condensate or Hot Water Meter Page 1 of 9 Page 1 of 9 PART 1 GENERAL 1.02 DESCRIPTION A. Purpose 1. This section covers steam condensate meters, steam condensate sub-meters and hot water sub-meters for use in the Owner's steam systems. 1.03 QUALIFICATIONS

More information

Absolute and Gage Pressure Transmitter

Absolute and Gage Pressure Transmitter Product Data Sheet 0083-000-4699 Absolute and Gage Pressure Transmitter ATRADITION OF EXCELLENCE IN THE PULP AND PAPER INDUSTRY Mounts flush to process media -inch flush mount compatible with a PMC process

More information

Thermo Scientific Ramsey TM Series Sensing Speed Conditions on Rotating Shafts and Machinery

Thermo Scientific Ramsey TM Series Sensing Speed Conditions on Rotating Shafts and Machinery Thermo Scientific Ramsey TM Series 60-200 Sensing Speed Conditions on Rotating Shafts and Machinery The Thermo Scientific Ramsey Series 60-200 monitors under-speed, overspeed and zero-speed conditions

More information

Rosemount 3100 Series Ultrasonic Level Transmitters

Rosemount 3100 Series Ultrasonic Level Transmitters Product Data Sheet Ultrasonic Level Transmitters Non-contacting measurement with no moving parts Integral LCD and push-buttons as standard for on-site programming Continuous measurement of level or distance-to-surface.

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Certificate: 1469131 (LR 103134) Master Contract: 184981 Issued to: Industrial Monitoring Instr. (IMI) A Div. of PCB Piezotronics, Inc. 3425 Walden Ave Depew, NY 14043 USA Attention:

More information

CERTIFICATE OF COMPLIANCE HAZARDOUS LOCATION ELECTRICAL EQUIPMENT PER CANADIAN REQUIREMENTS

CERTIFICATE OF COMPLIANCE HAZARDOUS LOCATION ELECTRICAL EQUIPMENT PER CANADIAN REQUIREMENTS j,!'. ;.'. FM Approvals 1151 Boston Providence Turnpike P.O. Box 9102 Norwood, MA 02062 USA T: 781 7624300 F: 781-762-9375 www.fmapprovals.com M('Ii/J(' (!li/w FM (i/(li1(// Groii/) CERTIFICATE OF COMPLIANCE

More information

ULTRA-SAFE Explosion-proof Duct Heaters

ULTRA-SAFE Explosion-proof Duct Heaters Standard Construction Heat Exchanger has copper tubes with integral aluminum fins. Each unit undergoes hydrostatic testing at 350 psig, five times the pressure relief valve setting of 70 psig. Heat Transfer

More information

EXCELLENCE in Solutions Products Service

EXCELLENCE in Solutions Products Service EXCELLENCE in Solutions Products Service Weed Instrument A World leader in Nuclear Qualified Instrumentation Weed Instrument has been supplying nuclear qualified temperature and pressure measurement instrumentation

More information

DIGITAL METERS Large Display Temperature Meters Instruction Manual

DIGITAL METERS Large Display Temperature Meters Instruction Manual DIGITAL METERS Large Display Temperature Meters PD755 PD756 PD757 Handles Thermocouple & RTD Inputs with Simplicity J, K, T, E, R, & S Thermocouples 100 Ω Platinum RTD (0.00385 or 0.00392 curve) Large

More information

vibration switch

vibration switch user manual 440-450 vibration switch INSTALLATION - OPERATION - MAINTENANCE Z0592822_A ISSUED 06/2017 READ AND UNDERSTAND THIS MANUAL PRIOR TO OPERATING OR SERVICING THIS PRODUCT. contents Section 1 -

More information

MEAS CAL ALARM CONF APT2000 CC ENCLOSURE TYPE 2

MEAS CAL ALARM CONF APT2000 CC ENCLOSURE TYPE 2 APT2000 Series 2-Wire Contacting Conductivity Transmitters Overview The Honeywell Analytical Process Transmitter (APT) 2000 Series transmitter is a two-wire 24-Volt device that continuously measures conductivity,

More information

Oxygen (O2) Single-Point Gas Detection System

Oxygen (O2) Single-Point Gas Detection System Oxygen (O) Single-Point Gas Detection System DESCRIPTION Wall-mounted gas monitor with built-in oxygen (O) sensor, accepts one analog remote device such as a secondary gas sensor, temperature or humidity

More information

Multi-Spectral, Digital, Infrared Electro-Optical. FSC Model No. s. Unitized, Two Stage, Quick Response Flame Detectors.

Multi-Spectral, Digital, Infrared Electro-Optical. FSC Model No. s. Unitized, Two Stage, Quick Response Flame Detectors. Fire Sentry Corporation (FSC) 593 Apollo Street Tel.: 714-671-1100 Brea, California 92821 Fax: 714-671-5821 Multi-Spectral, Digital, Infrared Electro-Optical FSC Model No. s FS10-R and FS10-A Unitized,

More information

Ramsey Motion Monitoring Systems

Ramsey Motion Monitoring Systems Ramsey Motion Monitoring Systems 60-200 Motion Monitoring Accurate Sensing of Underspeed, Overspeed and Zero Speed Conditions on Rotating Shafts and Machinery The Ramsey Series 60-200 Motion Monitoring

More information

Certificate of Compliance

Certificate of Compliance FF0002 Certificate of Compliance Certificate: 70009779 Issued to: Pepperl+Fuchs GmbH Lilienthalstrasse 200 Mannheim, 68307 GERMANY Attention: Martin Holdefer The products listed below are eligible to bear

More information

CR Series Command Relays

CR Series Command Relays CR Series Command Relays FEATURES INSTALLATION INSTRUCTIONS Patented 35mm Din-rail mounting flange (US Patent 7,416,421) SPDT Form 1C Relay contacts Pilot duty rated LED status indication Stackable for

More information

Pioneer-R16 Gas Monitor Operator s Manual

Pioneer-R16 Gas Monitor Operator s Manual Pioneer-R16 Gas Monitor Operator s Manual Edition 7/2/97 RKI INSTRUMENTS, INC RKI Instruments, Inc. 33248 Central Ave, Union City, CA 94587 (510) 441-5656 Chapter 1: Description About the Pioneer-R16 Gas

More information

RF Admittance Technology FACTS

RF Admittance Technology FACTS RF Admittance Technology FACTS Each year RF Admittance is the most purchased technology offered in electronic point level products Versatile technology, well proven in a wide range of applications in solid,

More information

Rosemount 2090P Pulp and Paper Pressure Transmitter

Rosemount 2090P Pulp and Paper Pressure Transmitter Product Data Sheet Rosemount 2090P Pulp and Paper Pressure Transmitter Rosemount 2090P 1-inch flush mount compatible with a PMC process connection, or 1 1 /2-inch threaded mounting connection Absolute

More information

SEC SIGNATURE ETO MONITOR TRAINING SENSOR ELECTRONICS CORPORATION

SEC SIGNATURE ETO MONITOR TRAINING SENSOR ELECTRONICS CORPORATION SEC SIGNATURE ETO MONITOR TRAINING SENSOR ELECTRONICS CORPORATION SEC SIGNATURE ETO MONITOR SIGETO1420597 PRODUCT INTRODUCED TO ETHYLENE OXIDE STERILIZATION INDUSTRY IN 2001. OVER 850 UNITS IN FIELD WORLDWIDE

More information

Model D12-IR. Digital Gas Transmitter...

Model D12-IR. Digital Gas Transmitter... Model D12-IR Digital Gas Transmitter... ATI s Series D12 gas transmitter line now includes a versatile Infrared system that can be configured for LEL or select toxic gases. The D12-IR utilizes a compact

More information

SAFETY MANUAL. Multispectrum IR Flame Detector X3301

SAFETY MANUAL. Multispectrum IR Flame Detector X3301 SAFETY MANUAL Multispectrum IR Flame Detector X3301 SAFETY-CERTIFIED MODEL X3301 MULTISPECTRUM INFRARED DETECTOR This manual addresses the specific requirements and recommendations applicable to the proper

More information

Model 144H. Product Data Sheet , Rev DB February Content

Model 144H. Product Data Sheet , Rev DB February Content Rosemount 144 PC-Programmable Temperature Transmitter Provides an installation-ready solution for temperature monitoring applications using Complete Point Solutions (CPS) Increases measurement accuracy

More information

Level Measurement Continuous level measurement Ultrasonic transmitters

Level Measurement Continuous level measurement Ultrasonic transmitters Overview Configuration is a short-range integrated ultrasonic level transmitter. This intrinsically safe, 2 wire, 4 to 20 ma loop powered transmitter is ideal for liquids, slurries, and bulk materials

More information

SEC Signature Process Gas Analyzer

SEC Signature Process Gas Analyzer SEC Signature Process Gas Analyzer Instruction and Operation Manual Sensor Electronics Corporation 5500 Lincoln Drive Minneapolis, Minnesota 55436 USA (952) 938-9486 Fax (952) 938-9617 email sensor@minn.net

More information

SOLID STATE SECURITIES, INC. THE "SS90" SERIES RELEASE DEVICES MADE IN THE U.S.A. SS90-WPS MODEL A/B INSTALLATION MANUAL

SOLID STATE SECURITIES, INC. THE SS90 SERIES RELEASE DEVICES MADE IN THE U.S.A. SS90-WPS MODEL A/B INSTALLATION MANUAL S S S S S S LISTED L * PATENT PENDING S S 90 OLID TATE ECURITIES, INC SOLID STATE FAIL-SAFE UNIT U 99Y9 RESET RELEASING DEVICE SOLID STATE SECURITIES, INC. THE "SS90" SERIES RELEASE DEVICES MADE IN THE

More information

Ring Detect Relays. Model RDR. Installation & Operation. Ph: \ \

Ring Detect Relays. Model RDR. Installation & Operation. Ph: \ \ Ring Detect Relays Installation & Operation P005116 Rev. E 180803 8/3/2018 11:19 AM Ph: 403.258.3100 \ email:info@guardiantelecom.com \ www.guardiantelecom.com Table of Contents Package Contents... 2 Models

More information

Model 6650SP. Filber Optic-Based UV-Fluorescence Oil-in-Water Analyzer

Model 6650SP. Filber Optic-Based UV-Fluorescence Oil-in-Water Analyzer Model 6650SP Filber Optic-Based UV-Fluorescence Oil-in-Water Analyzer 6650SP - OVERVIEW The Model 6650SP is the next generation in-water Analyzer. The 6650SP incorporates the most advanced, state-of-the-art

More information

MEAS CAL ALARM WASH CONF APT4000 CC ENCLOSURE TYPE 2

MEAS CAL ALARM WASH CONF APT4000 CC ENCLOSURE TYPE 2 APT4000 Series 4-Wire Contacting Conductivity Analyzers Overview 70-82-03-45 10/03 Page 1 of 8 Specification The Honeywell Analytical Process Analyzer (APT) 4000 Series2 continuously measures conductivity,

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Certificate: 2007104 Master Contract: 223077 Issued to: Purge Solutions 2201 North Highway 35 Bypass Suite C Alvin, TX 77511 USA Attention: Wallace Trochesset The products listed

More information

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW 12/23/16 Rev 9 UltraLITE Model ELU General Specification 4.2 KW to 5 KW UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW 1.0 General General Specification This specification describes

More information

PUV, PIR and PFO Series BROCHURE

PUV, PIR and PFO Series BROCHURE PUV, PIR and PFO Series BROCHURE JUNHO 2013 ABB Multiwave TM process photometers PUV3402, PIR3502 and PFO3372 Measure vapor and liquid samples in IR, NIR, UV and VIS regions Process photometers PUV3402,

More information

SNA-SKID Series - Preassembled Safety Shower Heater Skid Tankless Water Heating Solutions

SNA-SKID Series - Preassembled Safety Shower Heater Skid Tankless Water Heating Solutions Pre-assembled skid system Back-to-Back heater models, SNA & SNAR High Flow Demand Safety Shower Applications 216-288 kw (737,000-983,000 BTUs) Temperature overshoot purge system NEMA 4 enclosure standard

More information

Low Temperature Zirconia Oxygen Analyzer

Low Temperature Zirconia Oxygen Analyzer Data Sheet SS/ZDT FG Issue 10 Low Temperature Zirconia Oxygen Analyzer ZDT FG Environmental certification MCERTS SIRA certificate MC99000 1/00 User-friendly language options selectable system alarms comprehensive

More information

Rosemount 2120 Vibrating Fork Liquid Level Switch

Rosemount 2120 Vibrating Fork Liquid Level Switch Rosemount 2120 Rosemount 2120 Vibrating Fork Liquid Level Switch Function virtually unaffected by flow, bubbles, turbulence, foam, vibration, solids content, coating, properties of the liquid, and product

More information

Rosemount 2100 Series

Rosemount 2100 Series Rosemount 2100 Series Vibrating Fork Liquid Level Switches Level switches for demanding applications Reliable performance... Rosemount 2100 series vibrating fork level switches are suitable for virtually

More information

Ring Detect Relays. Model RDR. Installation & Operation. Ph: \ \

Ring Detect Relays. Model RDR. Installation & Operation. Ph: \ \ Ring Detect Relays Installation & Operation P005116 Rev. D 141020 10/20/2014 11:25 AM Ph: 403.258.3100 \ email:info@guardiantelecom.com \ www.guardiantelecom.com Table of Contents Package Contents...2

More information

Rosemount 2120 Vibrating Fork Liquid Level Switch

Rosemount 2120 Vibrating Fork Liquid Level Switch Product Data Sheet Rosemount 2120 Rosemount 2120 Vibrating Fork Liquid Level Switch Function virtually unaffected by flow, bubbles, turbulence, foam, vibration, solids content, coating, properties of the

More information

Capital Controls SERIES 70CV3000 CHLOROMATIC VALVE

Capital Controls SERIES 70CV3000 CHLOROMATIC VALVE Capital Controls SERIES 70CV3000 CHLOROMATIC VALVE Integrated Gas Control Valve with Integral Controller The Series 70CV3000 Chloromatic Intelligent Gas Flow Control Valve is designed to control chemical

More information

Page. 1-2 Sepra-Lite Integral Optic Level Switches. 3-5 Electro Optic Level Systems: Probe and Controller

Page. 1-2 Sepra-Lite Integral Optic Level Switches. 3-5 Electro Optic Level Systems: Probe and Controller Order from: C A Briggs Company 622 Mary Street; Suite 101; Warminster, PA 18974 Phone: 267-673-8117-800-352-6265; Fax: 267-673-8118 Sales@cabriggs.com - www.cabriggs.com Page 1-2 Sepra-Lite Integral Optic

More information

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors Dräger Polytron 5700 Fixed Gas Detector Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors Dräger Polytron 5700 Including e-box for increased safety wiring The Dräger

More information

The Sub-Mini Hermet. OEM Pressure Switches Sub-Mini-Hermet and Omni

The Sub-Mini Hermet. OEM Pressure Switches Sub-Mini-Hermet and Omni OEM Pressure Sub-Mini-Hermet and Omni Factory Set Sub-Mini-Hermet The Sub-Mini Hermet has the ability to be externally adjusted without disconnecting electrical service or tamperproof. These field mounted

More information

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

Nitrogen Dioxide (NO2) Single-Point Gas Detection System Nitrogen Dioxide (NO) Single-Point Gas Detection System DESCRIPTION Wall-mounted gas monitor with built-in nitrogen dioxide (NO)/diesel fume gas sensor, accepts one analog remote device such as a secondary

More information

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual We manage heat MANUAL Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual 1850 N Sheridan Street South Bend, Indiana 46628 (574) 233-1202 or (800) 234-4239

More information

Nuclear Density Gauges

Nuclear Density Gauges Nuclear Density Gauges DensityPRO DensityPRO+ DensityPRO-C ConsistencyPRO CutPRO 3680 Authorised Distributor www.transmin.com.au Thermo Scientific Nuclear Density Gauges Energy Attenuation Gauges The expandable

More information

Model Q45P/R. ph/orp Monitor...

Model Q45P/R. ph/orp Monitor... Model Q45P/R ph/orp Monitor... Sensor Mounting Configurations The Differential Difference ORP Monitor ATI's versatile Q45P/R ph/orp system is designed for use in all industrial and municipal applications.

More information

WFDE Series Waterflow Detector

WFDE Series Waterflow Detector WFDE Series Waterflow Detector The System Sensor WFDE series is compatible with pipe diameters ranging from 50mm through 200mm and can be mounted in a vertical or horizontal position. Features Compliant

More information

air.iq Moisture Analyzer Packaged Solution GE Measurement & Control Applications Features

air.iq Moisture Analyzer Packaged Solution GE Measurement & Control Applications Features GE Measurement & Control air.iq Moisture Analyzer Packaged Solution Features Applications air.iq simplifies the selection and installation of your moisture analyzer. Install the moisture probe, wire your

More information

SAFETY MANUAL. X2200 UV, X9800 IR, X5200 UVIR SIL 2 Certified Flame Detectors

SAFETY MANUAL. X2200 UV, X9800 IR, X5200 UVIR SIL 2 Certified Flame Detectors SAFETY MANUAL X2200 UV, X9800 IR, X5200 UVIR SIL 2 Certified Flame Detectors SAFETY-CERTIFIED Flame DETECTORs This manual addresses the specific requirements and recommendations applicable to the proper

More information

GG-EM ENTRANCE MONITOR. Installation and Operation Manual

GG-EM ENTRANCE MONITOR. Installation and Operation Manual GG-EM ENTRANCE MONITOR Installation and Operation Manual 2 GG-EM Warning Use this product only in the manner described in this manual. If the equipment is used in a manner not specified by Calibration

More information

The Clark-Reliance Corporation TWIP System Installation and Maintenance Instructions - Form E112 -

The Clark-Reliance Corporation TWIP System Installation and Maintenance Instructions - Form E112 - The Clark-Reliance Corporation TWIP System Installation and Maintenance Instructions - Form E112 - Table of Contents A. Installation Page 2 B. Interwiring Control Unit Options Page 3 C. Operation Page

More information

Differential pressure gauge with electrical contact type Model: P650 series

Differential pressure gauge with electrical contact type Model: P650 series Differential pressure gauge with electrical contact type Model: P650 series Service intended The P650 series are designed to measure a differential pressure from 25 kpa to 2.0 MPa at static pressure up

More information

Model Q45P/R. ph/orp Monitor...

Model Q45P/R. ph/orp Monitor... Model Q45P/R ph/orp Monitor... Sensor Mounting Configurations The Differential Difference ORP Monitor ATI's versatile Q45P/R ph/orp system is designed for use in all industrial and municipal applications.

More information

D SYSTEM CONTROL DWG. APPROVED BY. OrCAD 6 ROSEMOUNT 2410

D SYSTEM CONTROL DWG. APPROVED BY. OrCAD 6 ROSEMOUNT 2410 FIELDBUS INTRINSICALLY SAFE CONCEPT (FISCO) APPROVAL FISCO allows interconnection of intrinsically safe apparatus to associated apparatus not specially examined in such combination. The criteria for interconnection

More information

MSM400 Ultrasonic Suspended Solids Monitoring and Control System

MSM400 Ultrasonic Suspended Solids Monitoring and Control System Product Data Sheet MSM400 Ultrasonic Suspended Solids Monitoring and Control System Continuous sludge discharge monitor for up to 50% suspended solid The MSM400 system contains a control unit and either

More information

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Dräger Polytron 5100 EC Detection of toxic gases and vapors Dräger Polytron 5100 EC Detection of toxic gases and vapors The Dräger Polytron 5100 EC is a cost-effective explosion proof transmitter for the detection of toxic gases or oxygen. It uses a high performance

More information

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL TRACON MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL TABLE OF CONTENTS FPT 130 Overview... 2 Installation... 3 Power Source and Load Connections... 4 Temperature Sensor... 5 External

More information

Cimco Series 21. Series 21 - Specifications INDEX. Description. Operational Specification 2

Cimco Series 21. Series 21 - Specifications INDEX. Description. Operational Specification 2 Series 21 - Specifications INDEX Description Page Operational Specification 2 Analog Operational Specification - Communications Options 3 Digital Operational Specification - Communications Options 4 Hardware

More information

Models 4623, 4628 & 5999/980 USP<645> Conductivity Analyzers

Models 4623, 4628 & 5999/980 USP<645> Conductivity Analyzers Data sheet USP Conductivity Analyzers A conductivity system designed to meet USP for the Pharmaceutical Industry incorporating automatic Stage 1 test Meets USP requirements ensures compliance

More information

MagMaster MFE flowmeters feature an innovative multifrequency

MagMaster MFE flowmeters feature an innovative multifrequency INDUSTRIAL INSTRUMENTS AND CONTROLS SPECIALIST Kent-Taylor MagMaster MFE Series Flowmeters Electromagnetic Sensors Features Include Unrivalled flow performance- ±0.2% accuracy. Pulsed DC Technology Incorporates

More information