1 Chubb Monitoring Solutions

2 A fire or security system is only as effective as the response that it initiates. A comprehensive security / life safety solution must include effective alarm monitoring. It s how alarm conditions identified by your on-site system are turned into an appropriate notification, a dispatch of authorities or other prescribed action. This plays a major role in limiting the impact of unwanted events on both people and property, helping to control losses of all types and to minimize interruptions in normal activity. Signals That Can Be Monitored Chubb Monitoring Centres are capable of receiving and processing a varied range of alarm signals including: Intrusion Detection Temperature Moisture / Water Level Tamper (signal indicating unauthorized interference with the alarm panel) Vibration Panic Hold-up Man-down Medical Emergency Supervisory (lost connection to Monitoring Centre) Sprinkler water flow Sprinkler supervisory/tamper Fire alarm panel - fire, trouble, supervisory Fire, Heat, Smoke

3

4 Communication Technologies A number of options exist to connect your local system(s) to the Chubb Monitoring Centres. Common communication technologies include: Digital alarm signals are transmitted across normal telephone lines. Cellular alarm signals move through established cellular networks, typically used as a backup to digital or IP IP (Internet Protocol) alarm signals are transmitted over the internet or private networks. IP connectivity allows the line to be polled or supervised to enhance the security of your connection to the Chubb Monitoring Centre. A Chubb sales professional can assist you in selecting the most appropriate approach for your application.

5

6 The Value of a Monitored Solution In an emergency situation, seconds count. That s why proper monitoring of your fire and / or security solution is so important. A fast and appropriate response can avoid damages, losses or even save lives. A comprehensive monitoring solution, which may include extended remote video monitoring services such as video verification of alarms, will alert our highly trained Chubb team of operators of an on-site issue or potential risk. This allows concerns to be addressed before they escalate. Building codes often mandate monitoring solutions certified by Underwriter Laboratories of Canada (ULC) as a condition of occupancy. Similarly, insurers can require proof of monitoring before offering preferred rates. Monitoring is recognized as an essential part of a security and life safety solution.

7

8 Standards and Certifications Underwriter s Laboratories of Canada (ULC) is an organization incorporated in 1920 by the Canadian federal government. It maintains and operates laboratories and certification centres for the examination, testing and classification of devices, construction, materials and systems for a number of industries including monitoring facilities and processes. ULC is accredited by the Standards Council of Canada as a certification organization, a testing organization and a standards development organization under the National Standards System of Canada. Chubb's Fire Signal Receiving Centres, Satellite Centres, and Service Centres are ULC listed and therefore authorized to issue ULC certificates within their listing category. A ULC certificate provides an increased level of assurance of compliance with the applicable Codes and Standards, which include defined performance criteria for quickly identifying and responding to risks to personal safety and /or property damage. The National Building Code of Canada requires notification of the fire department in conformance with CAN/ULC-S561-13, Installation and Services for Fire Signal Receiving Centres and Systems for: A single stage fire alarm system installed in a building of assembly occupancy that has an occupant load more than 300. A fire alarm system that includes waterflow-indicating devices. A 2-stage fire alarm system. The National Fire Code of Canada requires that existing fire alarm systems in the secured premises be inspected and tested in conformance with CAN/ ULC-S536, and that Central Stations be maintained in conformance with CAN/ULC-S561. Those ULC Standards, in turn, include requirements for the inspection and testing of the monitoring of these secured premises. Preexisting systems installed prior to the original introduction of CAN/ULC-S561 in 2003 may be eligible to be grandfathered if compliant with the previous requirements of ULC-ORD-C Please contact Chubb for further information on CAN/ULC-S and local building codes. Please note that some provinces and territories either adopt or adapt the National Building Code of Canada and National Fire Code of Canada, while other provinces and territories, including BC, Alberta, Ontario, and Quebec, publish their own codes based on the model national codes. Also, local Authorities Having Jurisdiction may have additional requirements. Since requirements may vary in different jurisdictions throughout Canada, we recommend that you refer to the applicable codes in your region.

9

10 Monitoring Solutions From Chubb Chubb has an established and proven record of delivering monitoring services needed to properly secure people and property. Our ULC-listed monitoring facilities and processes have been extensively tested and are regularly audited by ULC inspectors to ensure continued compliance with the most demanding of standards. In addition, Chubb can, for an additional fee, provide a ULC certificate confirming that the system installation, service, inspections and monitoring meet the applicable ULC standards through a comprehensive audit. Ensure your system is effective. For more information on Chubb's monitoring services, please contact Chubb at or visit

11

12 Chubb is a leading provider of end-to-end solutions for fire & security requirements that can address system design, production, installation, service, monitoring and continuing customer care. Its focus is integration, allowing all components of a system to operate as one, including intrusion detection, access control, video surveillance, nurse call and communications, fire systems, sprinklers and monitoring. Chubb is a part of UTC Building & Industrial Systems, a unit of United Technologies Corp. (NYSE: UTX), a leading provider to the aerospace and building systems industries worldwide. MKTG Chubb Fire Security Tel: (800) Fax: (905) marketing@chubbedwards.com website:

CAN/ULC-S561. To comply, or not to comply. actually it s not even a question! Underwriters Laboratories of Canada. By Alan Cavers & Brian McBain

CAN/ULC-S561. To comply, or not to comply. actually it s not even a question! Underwriters Laboratories of Canada. By Alan Cavers & Brian McBain CAN/ULC-S561 To comply, or not to comply. actually it s not even a question! By Alan Cavers & Brian McBain CAN/ULC-S561, Installation And Services For Fire Signal Receiving Centres And Systems is without

More information

Fire Signal Receiving Centres vs. Proprietary Fire Signal Receiving Centres CAN/ULC-S561 ALAN CAVERS ULC

Fire Signal Receiving Centres vs. Proprietary Fire Signal Receiving Centres CAN/ULC-S561 ALAN CAVERS ULC Fire Signal Receiving Centres vs. Proprietary Fire Signal Receiving Centres CAN/ULC-S561 ALAN CAVERS ULC Reliable Fire Alarm Monitoring Why is it important? Codes and Standards? What is a fire alarm monitoring?

More information

A Building Manager s Guide to Maintaining Fire Code Compliance

A Building Manager s Guide to Maintaining Fire Code Compliance A Building Manager s Guide to Maintaining Fire Code Compliance Know your role in conducting fire protection system inspections : Fire Alarm Codes and Standards Maintaining your compliance with fire code

More information

BULLETIN BU/EL Revised August 11, 2015

BULLETIN BU/EL Revised August 11, 2015 BULLETIN 2000-019-BU/EL Revised August 11, 2015 TRANSMITTING UNIT FROM PROTECTED PREMISES TO FIRE SIGNAL RECEIVING CENTRE IN CONFORMANCE WITH CAN/ULC-S561 The intent of this bulletin is to clarify the

More information

COMMERCIAL (IBC) FIRE ALARM SUBMITTAL GUIDE

COMMERCIAL (IBC) FIRE ALARM SUBMITTAL GUIDE COMMERCIAL (IBC) FIRE ALARM SUBMITTAL GUIDE SUPERVISION OF AUTOMATIC FIRE SPRINKLER SYSTEMS SUPERVISION OF ALTERNATIVE AUTOMATIC FIRE-EXTINGUISHING SYSTEMS FIRE ALARM AND DETECTION SYSTEMS The Fire Alarm

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-28 20 02 (November 2008) ----------------------------- Preparing Activity: USACE Superseding UFGS-13729 (April 2006) UNIFIED FACILITIES GUIDE SPECIFICATIONS References

More information

Advantage Services Capabilities

Advantage Services Capabilities Advantage Capabilities Achieve optimal results for the life of your facility. www.usa.siemens.com/service Building Automation Ensures automation systems and controls are performing at optimal levels, maintaining

More information

Comprehensive Security for Banks and Credit Unions

Comprehensive Security for Banks and Credit Unions Comprehensive Security for Banks and Credit Unions Trust a Turnkey Solutions Provider As a leading security provider, STANLEY Security understands the needs of financial institutions like yours and has

More information

Rancho Cucamonga Fire Protection District Prevention Bureau Standard

Rancho Cucamonga Fire Protection District Prevention Bureau Standard Rancho Cucamonga Fire Protection District Prevention Bureau Standard Title: Fire Alarm and Monitoring Systems Standard # 9-3 Effective: May 2002 Number of Pages: 7 Updated: December 2016 for consistency

More information

WEBWA al Y arm 2 sig 4 nall2 in 4

WEBWA al Y arm 2 sig 4 nall2 in 4 EBWAY 2424 alarm signalling WebWay 2424 page 3 WebWay 2424 MANAGED SERVICES WebWay 2424 managed alarm signalling improves security and site management using the latest communications technology saving

More information

Applying Performance-based Fire Alarm System Design Part 4

Applying Performance-based Fire Alarm System Design Part 4 Fire Alarm Notebook by Dean K. Wilson. P.E. Page 1 Applying Performance-based Fire Alarm System Design Part 4 by Dean K. Wilson, P.E. Over the course of the last four issues I have continued to discuss

More information

FIRE & LIFE SAFTEY STANDARD

FIRE & LIFE SAFTEY STANDARD Title: Effective Date: 01/01/14 Revised Date: 1/1/14 Code References: Title 16, Chapter 16.16 of the Roseville Municipal Code, NFPA 72 Note: This standard is a summary of Fire Department clarifications

More information

CAN/ULC-S INTEGRATED SYSTEMS TESTING OF FIRE PROTECTION AND LIFE SAFETY SYSTEMS

CAN/ULC-S INTEGRATED SYSTEMS TESTING OF FIRE PROTECTION AND LIFE SAFETY SYSTEMS 2013 Randal Brown & Associates Engineering Ltd. 1 RANDAL BROWN & ASSOCIATES ENGINEERING LTD. CONSULTING ENGINEERS LIFE SAFETY & FIRE PROTECTION 105 6 LANSING SQUARE TORONTO, ONTARIO CAN/ULC-S1001-11 INTEGRATED

More information

CAN/ULC-S1001, INTEGRATED SYSTEMS TEST OF FIRE PROTECTION AND LIFE SAFETY SYSTEMS

CAN/ULC-S1001, INTEGRATED SYSTEMS TEST OF FIRE PROTECTION AND LIFE SAFETY SYSTEMS RANDAL BROWN & ASSOCIATES ENGINEERING LTD. CONSULTING ENGINEERS LIFE SAFETY & FIRE PROTECTION 105 6 LANSING SQUARE TORONTO, ONTARIO CAN/ULC-S1001, INTEGRATED SYSTEMS TEST OF FIRE PROTECTION AND LIFE SAFETY

More information

CAN/ULC S Integrated Systems Testing of Fire Protection and Life Safety Systems and Fire Protection Commissioning

CAN/ULC S Integrated Systems Testing of Fire Protection and Life Safety Systems and Fire Protection Commissioning CAN/ULC S1001-11 Integrated Systems Testing of Fire Protection and Life Safety Systems and Fire Protection Commissioning Presentation To: Canadian Fire Alarm Association (CFAA) National Capital Region

More information

Florida Building Code Chapter 9 Fire Protection Systems Advanced Course

Florida Building Code Chapter 9 Fire Protection Systems Advanced Course Florida Building Code 2010 Chapter 9 Fire Protection Systems Advanced Course 1 Introduction This course will cover specific sections of Chapter 9 that relate to fire alarm systems. While many contractors

More information

OJD ITB No Attachment E Duress Alarm Equipment Specifications

OJD ITB No Attachment E Duress Alarm Equipment Specifications Duress Alarm Equipment Specifications PART 1 GENERAL 1.1 SECTION INCLUDES A. Duress devices. B. Alarm control panel. C. Signaling devices. 1.2 REFERENCE STANDARDS A. NFPA 70 - National Electrical Code;

More information

COPYRIGHT ULC STANDARDS

COPYRIGHT ULC STANDARDS CANADIAN CODES & ULC STANDARDS: AN OVERVIEW Mahendra (Mike) Prasad, C.E.T. Manager, International Standards CFAA Alberta Technical Seminar October 17, 2012 2011 Underwriters Laboratories Inc. 1 H T U LC

More information

Fort Rouge Leisure Centre Section HVAC Upgrades Phase 2 Page 1 of 5 Bid Opportunity No March 2013 FIRE ALARM SYSTEMS

Fort Rouge Leisure Centre Section HVAC Upgrades Phase 2 Page 1 of 5 Bid Opportunity No March 2013 FIRE ALARM SYSTEMS HVAC Upgrades Phase 2 Page 1 of 5 Part 1 General 1.1 SUMMARY.1 Section Includes:.1 Materials and installation for fire alarm systems upgrades..2 Audible signal devices..3 End-of-line devices..4 Sustainable

More information

Changes in NFPA

Changes in NFPA Changes in NFPA 72-2002 2002 Oregon Fire Code Committee November 25, 2003 Michael B. Baker, SET Automatic Fire Alarm Association MikeBaker@afaa.org 2003 Michael B. Baker 1 Table of Contents 1. Administration

More information

RE: PERMIT REQUIRED TO WORK ON FIRE ALARM SYSTEMS IN THE RMWB

RE: PERMIT REQUIRED TO WORK ON FIRE ALARM SYSTEMS IN THE RMWB Fire Prevention Branch Fire Hall # 5 200 Saprae Creek Trail Fort McMurray, AB T9H 4P1 November 8 th, 2017 RE: PERMIT REQUIRED TO WORK ON FIRE ALARM SYSTEMS IN THE RMWB All fire alarm system work permits

More information

CFAA Alberta Technical Seminar 2010

CFAA Alberta Technical Seminar 2010 CFAA Alberta Technical Seminar 2010 Kevan D. Jess Chief Fire Administrator Government of Alberta Fire Alarm Requirements AFC 2006 & ABC 2006 AFC 2006 deals with existing buildings, particularly maintenance

More information

PORTABLE FIRE EXTINGUISHERS

PORTABLE FIRE EXTINGUISHERS FIRE CODE BULLETIN February 2018 14-FCB-002 Page 1 of 6 PORTABLE FIRE EXTINGUISHERS PURPOSE This bulletin is to clarify the intent of the Alberta Fire Code 2014 (AFC 2014) and NFPA 10, Standard for Portable

More information

rpsa FIRE PROTECTION ENGINEERS

rpsa FIRE PROTECTION ENGINEERS FIRE PROTECTION ENGINEERS R.P. SCHIFILITI ASSOCIATES, INC. P.O. Box 297 Reading, Massachusetts 01867-0497 USA 781.944.9300 Fax / Data 781.942.7500 Telephone Elevator Fire Safety: Elevator Recall and Elevator

More information

SANTA CLARA COUNTY Winchester Blvd., Los Gatos, CA (408) (408) (fax)

SANTA CLARA COUNTY Winchester Blvd., Los Gatos, CA (408) (408) (fax) FIRE DEPARTMENT SANTA CLARA COUNTY 14700 Winchester Blvd., Los Gatos, CA. 95032-1818 (408) 378-4010 (408) 378-9342 (fax) www.sccfd.org STANDARD DETAILS & SPECIFICATIONS Spec No C-4 Rev. Date 03/10/10 SUBJECT:

More information

Canadian White Book. p/1

Canadian White Book. p/1 Canadian White Book p/1 the standard in safety / la norme en matière de securité Canadian White Book/Livre Blanc Canadien Contains all the product categories for all ULC and cul certifications. Contains

More information

Tyco Integrated Security Monitoring Services. Helping you secure your business 24 hours a day, 365 days a year. Safer. Smarter. Tyco.

Tyco Integrated Security Monitoring Services. Helping you secure your business 24 hours a day, 365 days a year. Safer. Smarter. Tyco. MONITORING ACCESS CONTROL VIDEO SURVEILLANCE INTRUSION DETECTION FIRE & LIFE SAFETY COMMERCIAL SOLUTIONS Tyco Integrated Security Monitoring Services Helping you secure your business 24 hours a day, 365

More information

Canadian Fire Alarm Association. Fire Alarm System Activation. Fire Alarm with malfunction history

Canadian Fire Alarm Association. Fire Alarm System Activation. Fire Alarm with malfunction history Canadian Fire Alarm Association Discussion topics False alarms Shut off notices Owner s responsibilities Documents required by AHJ Fire Alarm System Activation Fire detection (early warning at insipient

More information

Intelligent Security and Fire Solutions. Southern Africa

Intelligent Security and Fire Solutions. Southern Africa Intelligent Security and Fire Solutions Southern Africa Chubb Southern Africa page 01 MAKING YOUR WORLD A SAFER PLACE Building Possible Chubb Fire and Security South Africa offers one of the world s most

More information

Audio Verification and Notification Procedures

Audio Verification and Notification Procedures Audio Verification and Notification Procedures Revision 3.50 (version May 14, 2009) Sponsor Central Station Alarm Association (CSAA) Contents Foreword...iv Introduction...vi 1 Scope... 7 1.1 General...

More information

Redefining Customer Value

Redefining Customer Value Redefining Customer Value Fire Protection & Security Solutions from Tyco Integrated Fire & Security Your trusted business partner: Knowledgeable. Reliable. Innovative. In a world where business demands

More information

Florida Building Code 2010

Florida Building Code 2010 Introduction Florida Building Code 2010 Chapter 9 Fire Protection Systems This course will cover specific sections of Chapter 9 that relate to fire alarm systems. While many contractors are familiar with

More information

Monitoring solutions

Monitoring solutions Monitoring solutions Grade A1. Latest monitoring technology. Providing 24/7 coverage 365 days a year, our highly skilled monitoring teams offer vigilant protection. Valued and strong relationships With

More information

VERIFICATION OF FIRE ALARM SYSTEMS

VERIFICATION OF FIRE ALARM SYSTEMS DEVELOPMENT, BUILDINGS AND LICENSING Chief Building Official (CBO) and Building Code and Policy Building Policy Branch The intent of this bulletin is to clarify requirements of verification of the fire

More information

Florida Senate SB 982 By Senator Bennett

Florida Senate SB 982 By Senator Bennett By Senator Bennett 1 A bill to be entitled 2 An act relating to electrical and alarm system 3 contracting; amending s. 489.503, F.S.; 4 requiring certain contractors to be certified 5 pursuant to part

More information

Fixed Fire Protection Getting it right, Ensuring Performance and Value

Fixed Fire Protection Getting it right, Ensuring Performance and Value Fixed Fire Protection Getting it right, Ensuring Performance and Value 18 th May 2017 Stuart Lloyd, EngTech TIFireE Principal Risk Engineer Practice Leader Fire Protection Engineering Zurich Risk Engineering

More information

a guide to the interpretation of

a guide to the interpretation of a guide to the interpretation of EN50136-1-1 & EN50136-2-1 for alarm transmission systems & equipment June 2007 For other information please contact: British Security Industry Association t: 0845 389 3889

More information

CAN/ULC-S1001, INTEGRATED SYSTEMS TESTING OF FIRE PROTECTION & LIFE SAFETY SYSTEMS Simon Crosby, LEL, CET, CFPS October 21, 2015

CAN/ULC-S1001, INTEGRATED SYSTEMS TESTING OF FIRE PROTECTION & LIFE SAFETY SYSTEMS Simon Crosby, LEL, CET, CFPS October 21, 2015 CAN/ULC-S1001, INTEGRATED SYSTEMS TESTING OF FIRE PROTECTION & LIFE SAFETY SYSTEMS Simon Crosby, LEL, CET, CFPS October 21, 2015 Fire Commissioning in Canadian Codes and Standards BACKGROUND Why Commissioning?

More information

COURSE SYLLABUS FIRE ALARM AND FIRE SUPPRESSION SYSTEMS CORRESPONDENCE COURSE

COURSE SYLLABUS FIRE ALARM AND FIRE SUPPRESSION SYSTEMS CORRESPONDENCE COURSE COURSE SYLLABUS FIRE ALARM AND FIRE SUPPRESSION SYSTEMS CORRESPONDENCE COURSE 100130 Description The first part of the course presents the requirements for fire alarm systems. It describes the buildings

More information

PROTECTED PROPERTY. City: State: Zip Code: ALARM SERVICE COMPANY. City: State: Zip Code: COMMENTS AND CLARIFICATIONS ALARM SYSTEM DESCRIPTION

PROTECTED PROPERTY. City: State: Zip Code: ALARM SERVICE COMPANY. City: State: Zip Code: COMMENTS AND CLARIFICATIONS ALARM SYSTEM DESCRIPTION Underwriters Laboratories Inc. FIRE ALARM SYSTEM PRE-INSPECTION DATA SHEETS PLEASE RETURN COMPLETED FORMS TO UL PRIOR TO INSPECTION PROTECTED PROPERTY City: State: Zip Code: ALARM SERVICE COMPANY File

More information

Louis-Philippe Gagnon Alarm System Auditor UNDERWRITTERS LABORATORIES OF CANADA May 13 th, 2015

Louis-Philippe Gagnon Alarm System Auditor UNDERWRITTERS LABORATORIES OF CANADA May 13 th, 2015 Louis-Philippe Gagnon Alarm System Auditor UNDERWRITTERS LABORATORIES OF CANADA May 13 th, 2015 UL and the UL logo are trademarks of UL LLC 2012 GOALS OF INSPECTING AND TESTING POWER SUPPLIES Verify/inspect

More information

SECTION FIRE ALARM STANDARDS REVISED CONSTRUCTION STANDARD

SECTION FIRE ALARM STANDARDS REVISED CONSTRUCTION STANDARD PART 1 - GENERAL PURPOSE This Standard is intended to assure that fire detection/alarm systems at The University of Texas at Austin provide the highest level of fire safety possible. SCOPE This standard

More information

Project No Belleville Fire Hall/Headquarters and Emergency Operations Centre Section Belleville, Ontario Page 1 of 10

Project No Belleville Fire Hall/Headquarters and Emergency Operations Centre Section Belleville, Ontario Page 1 of 10 Belleville, Ontario Page 1 of 10 1 GENERAL 1.1 GENERAL REQUIREMENTS.1 The General Conditions of CCDC2-2008, and the General requirements of Division 1, form part of this Section and must read in conjunction

More information

This annex is valid from: to Replaces annex dated: Location(s) where activities are performed under accreditation

This annex is valid from: to Replaces annex dated: Location(s) where activities are performed under accreditation Location(s) where activities are performed under accreditation Head Office Edisonstraat 12A 6902 PK Zevenaar The Netherlands Activities trading under the names and Kiwa Telefication Fire alarm/detection

More information

CERTIFICATION BULLETIN

CERTIFICATION BULLETIN File: ULC-S527-11 ULC-G5.2 June 1, 2012 CERTIFICATION BULLETIN 2012-04 Effective Date Announcement CAN/ULC-S527-11, 3 rd Edition of the Standard for Control Unit for Fire Alarm Systems To: Subscribers

More information

Should you have further questions, please feel free to contact the Fire Prevention Branch.

Should you have further questions, please feel free to contact the Fire Prevention Branch. Fire Prevention Branch Fire Hall # 5 200 Saprae Creek Trail Fort McMurray, AB T9H 4P1 November 8 th, 2017 RE: PERMIT REQUIRED TO WORK ON SPECIAL FIRE SUPPRESSION SYSTEMS IN THE RMWB All annual special

More information

Update all extract references to NFPA documents (including NFPA 72) in Chapter 3 and related annex material to the latest editions.

Update all extract references to NFPA documents (including NFPA 72) in Chapter 3 and related annex material to the latest editions. 11/16/12 TerraView First Revision No. 15-NFPA 720-2012 [ Global Input ] Update all extract references to NFPA documents (including NFPA 72) in Chapter 3 and related annex material to the latest editions.

More information

SAFETY CODES COUNCIL ORDER. BEFORE THE FIRE TECHNICAL COUNCIL On June 21, 2012

SAFETY CODES COUNCIL ORDER. BEFORE THE FIRE TECHNICAL COUNCIL On June 21, 2012 SAFETY CODES COUNCIL #1000, 10665 Jasper Avenue N.W., Edmonton, Alberta, Canada, T5J 389 Tel: 780-413-0099 I 1-888-413-0099 Fax: 780-424-5134 I 1-888-424-5134 www.safetycodes.ab.ca COUNCIL ORDER No. 0015423

More information

KELTRON LS 7000 ALARM MANAGEMENT SYSTEM Keltron Alarm Monitoring, Dispatch, and Reporting Software

KELTRON LS 7000 ALARM MANAGEMENT SYSTEM Keltron Alarm Monitoring, Dispatch, and Reporting Software KELTRON LS 7000 ALARM MANAGEMENT SYSTEM Keltron Alarm Monitoring, Dispatch, and Reporting Software OVERVIEW The Keltron LS 7000 Alarm Management System software and computers make up the dispatch portion

More information

This annex is valid from: to Replaces annex dated: Location(s) where activities are performed under accreditation

This annex is valid from: to Replaces annex dated: Location(s) where activities are performed under accreditation Location(s) where activities are performed under accreditation Head Office Edisonstraat 12A 6902 PK Zevenaar The Netherlands Location Certification Scheme Edisonstraat 12A 6902 PK Zevenaar The Netherlands

More information

0 4 / 0 4 / 1 4. GE Concord 4 Quick User Guide. GE Concord 4 Quick User Guide Page 1

0 4 / 0 4 / 1 4. GE Concord 4 Quick User Guide. GE Concord 4 Quick User Guide Page 1 0 4 / 0 4 / 1 4 GE Concord 4 Quick User Guide GE Concord 4 Quick User Guide Page 1 Before Calling Is the keypad beeping? Press *. This will silence the beeping and let you know where the trouble is. Is

More information

OWNERS RESPONSIBILITIES & CASE STUDIES ONTARIO FIRE CODE. John Percy, Public Education Officer Waterloo Fire Rescue

OWNERS RESPONSIBILITIES & CASE STUDIES ONTARIO FIRE CODE. John Percy, Public Education Officer Waterloo Fire Rescue OWNERS RESPONSIBILITIES & CASE STUDIES ONTARIO FIRE CODE John Percy, Public Education Officer Waterloo Fire Rescue AGENDA: Fire Protection and Prevention Act and Ontario Fire Code Role of Assistants to

More information

DERRY FIRE DEPARTMENT LISTED AGENT CERTIFICATION PROGRAM

DERRY FIRE DEPARTMENT LISTED AGENT CERTIFICATION PROGRAM DERRY FIRE DEPARTMENT LISTED AGENT CERTIFICATION PROGRAM THIS COURSE IS FOR AGENTS WISHING TO DISABLE TRANSMITTING SIGNALS IN ORDER TO PERFORM MAINTENANCE TESTING AND DRILLS. OBJECTIVE The objective of

More information

Sec False alarms.

Sec False alarms. Sec. 16-5. - False alarms. (a) Definitions. The following words, when used in this section, shall have the meanings ascribed herein unless the context indicates otherwise: Agreement [means] police and/or

More information

FIRE DETECTION SYSTEM SPECIFICATION FOR MODEL XR200

FIRE DETECTION SYSTEM SPECIFICATION FOR MODEL XR200 FIRE DETECTION SYSTEM SPECIFICATION FOR MODEL XR200 1.0 General 1.1 Manufacturer Manufacturer of the Fire Alarm Control Panel (FACP) equipment shall be: Digital Monitoring Products, Incorporated 2500 N.

More information

SECTION INTRUSION DETECTION

SECTION INTRUSION DETECTION (NOTE TO DESIGNER: These Specifications are basic minimum criteria to be met in preparing the final specifications for this section, which is the responsibility of the Designer.) SECTION 28 16 00 INTRUSION

More information

THIS ORDINANCE ONLY AFFECTS EXISTING FIRE ALARM SYSTEMS.

THIS ORDINANCE ONLY AFFECTS EXISTING FIRE ALARM SYSTEMS. THIS ORDINANCE ONLY AFFECTS EXISTING FIRE ALARM SYSTEMS. IF YOU RECEIVED A NOTICE BY MAIL AND YOU DO NOT CURRENTLY HAVE A FIRE ALARM INSTALLED IN YOUR BUILDING, YOU MAY DISREGARD THE NOTICE. Dear Building

More information

Fire Alarm Wiring. Circuit types, styles and limitations

Fire Alarm Wiring. Circuit types, styles and limitations Fire Alarm Wiring Circuit types, styles and limitations What we will cover Types Classes Notification Appliance Circuits (NAC) Initiating Device Circuits (IDC) Signaling Line Circuits (SLC) Class A, B,

More information

Western Michigan University Facilities Management Engineering Division

Western Michigan University Facilities Management Engineering Division Western Michigan University Facilities Management Engineering Division Design Guidelines for Facilities Construction: DESIGN GUIDELINE DG21-1 Fire Suppression Systems & Equipment I. GENERAL... 1 A. General

More information

Chapter ALARM SYSTEMS

Chapter ALARM SYSTEMS Page 1 of 6 Chapter 15.12 ALARM SYSTEMS Sections: 15.12.010 Purpose. 15.12.020 Definitions. 15.12.030 Alarm system standards. 15.12.040 Alarm business standards. 15.12.050 Alarm use standards. 15.12.060

More information

FIRE ALARM AUDIBILITY IN EXISTING RESIDENTIAL OCCUPANCIES

FIRE ALARM AUDIBILITY IN EXISTING RESIDENTIAL OCCUPANCIES FIRE ALARM AUDIBILITY IN EXISTING RESIDENTIAL OCCUPANCIES Office of the Fire Marshal and Emergency Management Preface This guideline updates TG-02-1998 published in June 1998. Portions of the guideline

More information

NFPA Changes

NFPA Changes Chapter 21, Emergency Control Functions and Interfaces Summary. Chapter 21 is new. These requirements were formerly found in Chapter 6, Protected Premises Fire Alarm Systems. The term fire safety function

More information

S T A T E O F F L O R I D A D E P A R T M E N T O F J U V E N I L E J U S T I C E BUREAU OF MONITORING AND QUALITY IMPROVEMENT PROGRAM REPORT FOR

S T A T E O F F L O R I D A D E P A R T M E N T O F J U V E N I L E J U S T I C E BUREAU OF MONITORING AND QUALITY IMPROVEMENT PROGRAM REPORT FOR S T A T E O F F L O R I D A D E P A R T M E N T O F J U V E N I L E J U S T I C E BUREAU OF MONITORING AND QUALITY IMPROVEMENT PROGRAM REPORT FOR 3M Electronic Monitoring (Contract Provider) 1838 Gunn

More information

PROPOSED CHANGE TO THE 2012 BUILDING CODE O. REG. 332/12 AS AMENDED

PROPOSED CHANGE TO THE 2012 BUILDING CODE O. REG. 332/12 AS AMENDED Ministry of Municipal Affairs PROPOSED CHANGE TO THE 2012 BUILDING CODE O. REG. 332/12 AS AMENDED CHANGE NUMBER: SOURCE: B-03-02-07 Ontario-NBC CODE REFERENCE: Division B / 3.2.4.22. and 3.2.4.23. DESCRIPTION

More information

The WAVE Plus Instant Notification System for Schools and Colleges

The WAVE Plus Instant Notification System for Schools and Colleges Instant Notification System for Schools and Colleges Duress alarm has been activated in the School of Engineering! Schools strive to provide a safe environment for students and teachers. In an emergency,

More information

White Papers: Delayed Egress Hardware

White Papers: Delayed Egress Hardware www.sdcsecurity.com service@sdcsecurity.com [t] 800.413.8783 805.494.0622 [f] 805.494.8681 801 Avenida Acaso, C ox 3670, Camarillo CA 93011-3670 www.sdcsecurity.com White Papers: Delayed Egress Hardware

More information

Fire Alarm System Fundamentals

Fire Alarm System Fundamentals Fire Alarm System Fundamentals Mircom is the largest and oldest privately owned fire alarm and life safety manufacturer in North America and 5th largest overall with 50 years of industry experience. Mircom

More information

British Columbia Building Code 2006 Division B Part 3 Fire Protection, Occupant Safety and Accessibility Section 3.2 Building Fire Safety

British Columbia Building Code 2006 Division B Part 3 Fire Protection, Occupant Safety and Accessibility Section 3.2 Building Fire Safety Div B 3.2.1.1.(4), (5) & (6) Exceptions in Determining Building Height BCBC1998-3.2.1.1.(4), (5) & (7) replace (harmonize with NBC) - NBC 2005 has significant revisions to provisions for mezzanines. These

More information

Overview of Process for Certification to NFPA Standards for Fire and Emergency Services PPE. IOM Workshop on Certification of PPT April, 13, 2010

Overview of Process for Certification to NFPA Standards for Fire and Emergency Services PPE. IOM Workshop on Certification of PPT April, 13, 2010 Overview of Process for Certification to NFPA Standards for Fire and Emergency Services PPE IOM Workshop on Certification of PPT April, 13, 2010 NFPA Standards Provides voluntary consensus standards for

More information

Protecting Backup Generators and UPS Systems Against Risk of Fire

Protecting Backup Generators and UPS Systems Against Risk of Fire Protecting Backup Generators and UPS Systems Against Risk of Fire Meeting the Challenge with Clean Agent Supplementary Fire Detection and Suppression Protecting Backup Generators and UPS Against the Risk

More information

FIRE ALARM AUDIBILITY IN EXISTING RESIDENTIAL OCCUPANCIES. 1 of 7 11/12/ :26 PM

FIRE ALARM AUDIBILITY IN EXISTING RESIDENTIAL OCCUPANCIES. 1 of 7 11/12/ :26 PM 1 of 7 11/12/2009 10:26 PM Skip Navigation Central Site Contact Us Site Map Français OFM HOME ABOUT THE OFM FIRE SERVICE FIRE PROTECTION FIRE SAFETY & PUBLIC EDUCATION LEGISLATION PUBLICATIONS RESOURCES

More information

Ontario Homes for Special Needs Association

Ontario Homes for Special Needs Association Ontario Homes for Special Needs Association Response to the Ministry of Community Safety and Correctional Services Consultation on Fire Safety for Vulnerable Residents in Ontario March 28, 20011 For more

More information

Bold items are particular to the City of Euless

Bold items are particular to the City of Euless EULESS FIRE DEPARTMENT FIRE MARSHAL S OFFICE INFORMATION LINE: Revised 8/2004 Fire Chief Lee Koontz Fire Marshal Paul Smith EFD-FMO 3-1 2003 International Fire & Building Code as Amended NFPA Standards

More information

First Revision No NFPA [ Global Input ] Submitter Information Verification. Committee Statement

First Revision No NFPA [ Global Input ] Submitter Information Verification. Committee Statement of 43 10/20/2015 4:02 PM First Revision No. 2035-NFPA 101-2015 [ Global Input ] To 14.3.4.4.1, add an item (4) to read: (4) Carbon monoxide detectors shall be installed centrally located within occupiable

More information

ORDINANCE NO

ORDINANCE NO ORDINANCE NO. 2010-06 AN ORDINANCE OF THE CITY OF TOMBALL, TEXAS, AMENDING CHAPTER 26, EMERGENCY SERVICES OF THE CODE OF ORDINANCES OF THE CITY OF TOMBALL TO ESTABLISH POLICIES, PROCEDURES AND REGULATIONS

More information

BYLAW 5542 *******************************************************************************

BYLAW 5542 ******************************************************************************* BYLAW 5542 ********************** A BYLAW OF THE CITY OF LETHBRIDGE TO AUTHORIZE THE ESTABLISHMENT AND OPERATION OF A FIRE AND EMERGENCY SERVICES DEPARTMENT *******************************************************************************

More information

INDEX INDEX 2 FOREWARD 3 SECTION 1 COMPANY INFORMATION 4 SECTION 2 GRADING AND CERTIFICATION 5 SECTION 3: ADDITIONAL REQUIREMENTS 6 7

INDEX INDEX 2 FOREWARD 3 SECTION 1 COMPANY INFORMATION 4 SECTION 2 GRADING AND CERTIFICATION 5 SECTION 3: ADDITIONAL REQUIREMENTS 6 7 Code of Practice INDEX INDEX 2 FOREWARD 3 SECTION 1 COMPANY INFORMATION 4 SECTION 2 GRADING AND CERTIFICATION 5 SECTION 3: ADDITIONAL REQUIREMENTS 6 7 SECTION 4 EMERGENCY SERVICES 8 9 SECTION 5 POLICE

More information

APPLICATION NOTE. Introduction. Contents DMP DATA NETWORK CERTIFICATES APPLICATION NOTE

APPLICATION NOTE. Introduction. Contents DMP DATA NETWORK CERTIFICATES APPLICATION NOTE Contents Introduction...1 UL Approves Public Data Networks. 1 Analog communication... 1 DMP network communication... 2 AMCX Central Station Alarm Units.. 2 APAW Police Station Alarm Units... 2 APOU Proprietary

More information

CHAPTER 05 - OFFICE OF STATE FIRE MARSHAL SUBCHAPTER 05A - FIRE AND RESCUE SECTION.0900 PUBLIC PROTECTION CLASSIFICATIONS FOR FIRE DISTRICTS

CHAPTER 05 - OFFICE OF STATE FIRE MARSHAL SUBCHAPTER 05A - FIRE AND RESCUE SECTION.0900 PUBLIC PROTECTION CLASSIFICATIONS FOR FIRE DISTRICTS CHAPTER 05 - OFFICE OF STATE FIRE MARSHAL SUBCHAPTER 05A - FIRE AND RESCUE SECTION.0900 PUBLIC PROTECTION CLASSIFICATIONS FOR FIRE DISTRICTS 11 NCAC 05A.0901 DEFINITIONS As used in this Subchapter: (1)

More information

Moreno Valley Fire Department Fire Prevention Bureau. New and Existing Fire Alarm & Signaling Systems Guideline

Moreno Valley Fire Department Fire Prevention Bureau. New and Existing Fire Alarm & Signaling Systems Guideline Moreno Valley Fire Department Guideline Approved and Authorized By: Adria Reinertson, Fire Marshal Issued: May 8, 2017 Alarm & Signaling Systems PURPOSE Fire alarm and signaling systems are designed to

More information

Page 1 of 5 CHAPTER 99 ALARM SYSTEMS [HISTORY: Adopted by the Township Committee of the Township of Hamilton as indicated in article histories. Amendments noted where applicable.] GENERAL REFERENCES Police

More information

MAINTENANCE OF FIRE PROTECTION DEVICES WITHIN RESIDENTIAL SUITES OF MULTI-FAMILY BUILDINGS

MAINTENANCE OF FIRE PROTECTION DEVICES WITHIN RESIDENTIAL SUITES OF MULTI-FAMILY BUILDINGS FIRE CODE BULLETIN December 2004 97 FCB 018 (R1) Page 1 of 5 BACKGROUND: MAINTENANCE OF FIRE PROTECTION DEVICES WITHIN RESIDENTIAL SUITES OF MULTI-FAMILY BUILDINGS Fire protection service companies are

More information

WFDE Series Waterflow Detector

WFDE Series Waterflow Detector WFDE Series Waterflow Detector The System Sensor WFDE series is compatible with pipe diameters ranging from 50mm through 200mm and can be mounted in a vertical or horizontal position. Features Compliant

More information

ALARM RESPONSE POLICY

ALARM RESPONSE POLICY ALARM RESPONSE POLICY JULY 1, 2014 ALARM RESPONSE Peel Regional Police respond on a daily basis to alarm call requests. In 2013, Peel Police received 13,660 alarm calls of which only 3% were valid. Every

More information

RAM-208. Remote Multiplex Annunciator Panel. Wiring & Installation Installation Manual COMMON TROUBLE A.C. ON SIGNAL SILENCED BUZZER SILENCE

RAM-208. Remote Multiplex Annunciator Panel. Wiring & Installation Installation Manual COMMON TROUBLE A.C. ON SIGNAL SILENCED BUZZER SILENCE Advanced Life Safety Solutions RAM-208 Remote Multiplex Annunciator Panel A.C. ON COMMON TROUBLE SIGNAL SILENCED BUZZER SILENCE SIGNAL SILENCE LAMP TEST SYSTEM RESET Wiring & Installation Installation

More information

FIRE PROTECTION PROGRAM

FIRE PROTECTION PROGRAM Fire Protection Program Page 1 of 13 FIRE PROTECTION PROGRAM 1.0 Objective The objective of this performance assessment is to evaluate the effectiveness of the laboratory's fire protection program as implemented

More information

FIRE ALARM SYSTEM 1.1 GENERAL REQUIREMENTS

FIRE ALARM SYSTEM 1.1 GENERAL REQUIREMENTS VALOUR COMMUNITY CENTRE FIRE ALARM SYSTEM Section 28 00 00 GYMNASIUM ADDITION & RENOVATION Page 1 of 3 28 00 00 FIRE ALARM SYSTEM 1.1 GENERAL REQUIREMENTS 1.2 SCOPE 1. The specification covering the General

More information

A. Hydraulic calculations shall be prepared in accordance with Chapter 23 of NFPA 13 with the following exceptions:

A. Hydraulic calculations shall be prepared in accordance with Chapter 23 of NFPA 13 with the following exceptions: SECTION 21 13 13 WET-PIPE FIRE SPRINKLER SYSTEM PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Division 1, "General Requirements", and Section

More information

The CWSI System CALL WITH QUESTIONS. RELY ON OUR KNOWLEDGE. DEPEND ON OUR EXPERIENCE. (800)

The CWSI System CALL WITH QUESTIONS. RELY ON OUR KNOWLEDGE. DEPEND ON OUR EXPERIENCE. (800) The CWSI System The CWSI wireless fire alarm product line offers system versatility like none other. Frequency Hopping Spread Spectrum Technology (FHSS), coupled with Bi-directional RF Communication, Repeater

More information

Authorized individuals to be notified. Include two (2) persons with access to the premises to allow emergency access.

Authorized individuals to be notified. Include two (2) persons with access to the premises to allow emergency access. Registration of Private Alarm Systems Town of Lincoln Date: $25.00 Registration $10.00 Renewal Address of Alarmed Property: Phone # of Alarmed Property: Owner s Name: Owner s Home Address: Owner s Home

More information

ORDINANCE NO

ORDINANCE NO ORDINANCE NO. 2014-01-1465 AN ORDINANCE OF THE CITY COUNCIL OF THE CITY OF SIGNAL HILL, CALIFORNIA, AMENDING CHAPTER 8.48 OF THE SIGNAL HILL MUNICIPAL CODE, ENTITLED SECURITY ALARM SYSTEMS, TO ADOPT A

More information

El Reno Fire Department Fire Alarm Plan Review Worksheet

El Reno Fire Department Fire Alarm Plan Review Worksheet El Reno Fire Department Fire Alarm Plan Review Worksheet This Fire Alarm Plan Review Checklist is provided as a guide to assist with your Fire Alarm Plan Review Submittal requirements. Please contact us

More information

Fire, Smoke and Control Dampers

Fire, Smoke and Control Dampers MANUAL Fire, Smoke and Control Dampers v100 Issue Date: 04/02/15 2015 Price Industries Limited. All rights reserved. TABLE OF CONTENTS Maintenance, Testing and Inspection Recommendations Recommended Maintenance

More information

Installation Manual Premier LCD/LCDL INS180-4

Installation Manual Premier LCD/LCDL INS180-4 Installation Manual Premier LCD/LCDL INS180-4 1. UL/C-UL Requirements Only the following keypads are to be used in a UL/C-UL Installation. Model No DBD-0135 DBD-0133 DBD-0144 DBD-0143 DBD-0148 DBD-0147

More information

Clarification. Summary of Changes. Summary of Changes. Alan Cavers Area Manager Fire & Security Systems Group

Clarification. Summary of Changes. Summary of Changes. Alan Cavers Area Manager Fire & Security Systems Group Summary of Changes CAN/ULC-S524-06 Installation of Fire Alarm Systems Alan Cavers Area Manager Fire & Security Systems Group Course Title Rev Date: Summary of Changes Correct Deficiencies noted CAN/ULC-S524-01

More information

Contact ID as of 2/2/2015

Contact ID as of 2/2/2015 Contact ID as of 2/2/2015 100 Medical Zone A non-specific medical exists 101 Personal Emergency Zone Emergency Assistance request 102 Fail to report in Zone A user has failed to activate a monitoring device

More information

Balloting Version First Draft NFPA 101 Life Safety Code Proposed 2015 Edition

Balloting Version First Draft NFPA 101 Life Safety Code Proposed 2015 Edition Copyright National Fire Protection Association 2013. All rights reserved. This copy is solely for your personal, noncommercial use in connection with participation in the NFPA Standards Development Process.

More information

CALL FOR A FREE SURVEY

CALL FOR A FREE SURVEY CCTV FIRE & SECURITY SOLUTIONS MADE SAFE CCTV Systems specifically designed and tailored for the commercial CCTV market What is CCTV? Closed-circuit television (CCTV), also known as video surveillance,

More information

CITY OF SURREY BY-LAW NO SURREY SECURITY AND FIRE ALARM BY-LAW,

CITY OF SURREY BY-LAW NO SURREY SECURITY AND FIRE ALARM BY-LAW, CITY OF SURREY BY-LAW NO. 13168 SURREY SECURITY AND FIRE ALARM BY-LAW, 1997... As amended by By-law No. 14452, 07/30/01; 16208, 01/15/07; 16529, 01/14/08; 16856, 01/19/09; 17079, 12/14/09; 17322, 01/10/11;

More information

Releasing Systems. Rob Mennie Senior Consultant Gage-Babcock & Associates Ltd.

Releasing Systems. Rob Mennie Senior Consultant Gage-Babcock & Associates Ltd. Releasing Systems Rob Mennie Senior Consultant Gage-Babcock & Associates Ltd. Releasing Systems What is a releasing system? System designed to detect a fire Causes release of an extinguishing system in

More information