Conventional Fire Alarm Systems. ACCLAIM SERIES 10 Conventional Fire Alarm System ACCLAIM SERIES 10.

Size: px
Start display at page:

Download "Conventional Fire Alarm Systems. ACCLAIM SERIES 10 Conventional Fire Alarm System ACCLAIM SERIES 10."

Transcription

1 FIRE DETECTION : FIRE SUPPRESSION EMERGENCY VOICE COMMUNICATIONS SYSTEM INTEGRATION ACCLAIM SERIES 10 s

2 Building the system you need ACCLAIM SERIES 10 Fire Alarm Panel provides many flexible choices from basic conventional (non-addressable) panel to advance hard-wire addressable panel / systems. The basic conventional panels are available from 4 to 136 zones. The design is compact, attractive, user friendly and highly scalable. The panels are built with well proven solid state technology for long term cost effectiveness. Operation and maintenance of the panel are provided with general frontal indications and colour coded switches. The specific fault indications are mounted behind the front indications. It is able to work with most conventional fire alarm system (panels &devices) thus allowing stage by stage system upgrades and eliminate vendor lock-in problems. Applications Acclaim Series 10 Fire Alarm Panel is suitable for use in commercial complexes, schools, car parks, hospitals, hotels, warehouses, factories, data centres, condominiums etc. Benefits Compatibility : works with many other make of equipment, panels and devices Flexibility : wide range of auxiliary panels to meet each requirement. eg: Fire Extinguishing, Smoke Control, Pre-action etc. Wide range of detectors : works with all approved makes of conventional detectors

3 Low maintenance cost : system can be maintained and Reliability : system designed with proven solid state serviced by fire servicing contractors detection technology Alarm interlocks : general sounder silencing and system Local manufacturer support : system designed and sup- resetting or system with multiple panels ported locally by highly experienced support team Ease of use : one touch operation - easy to learn and Compliance : BS EN 54 Parts 2 & 4 :1998 and SS CP- reduces errors 10:2005 Diagnostic facilities : informative diagnostic LED indica- Approval : PSB Listed (4 to 136 zones) tors for easy identification and rectification of faults The Acclaim Series Hybrid Fire Alarm Panel provides many flexible, user friendly features that overcome the limitations found in today s conventional fire alarm systems. Its Performance, Reliability, Versatility and Unique Features greatly improve operational efficiency and productivity. Various upgrade options are available to enhance the fire alarm system such as: Auxiliary Status and Control Module provides addition indicators and control switches to be added to the panel for easy identification and control. The Alarm Verification Feature greatly reduces the disruption caused by unwanted false alarms. The LCD Display Unit automatically records the fire and alarm events with date and time, eliminating inaccurate or missing records due to human errors. Networking facility of the LCD Unit allows up to 32 panels to be networked and monitored from one centralized location. Zone (and device address, if hardwire addressable option is implemented) can be identified from the Main Alarm Panel thus reducing response time. Graphic User Interface guides duty staff to area in alarm in the shortest time possible. The Graphics User Interface also records events with date, time and operator information. The event storage capacity is only limited by the capacity of the hard disk of the PC. Various reports can be generated for post event analysis to help identify the cause and take preventive measures against future disruptions.

4 CONTROL PANELS & ACCESSORIES ACCLAIM SERIES 10 FIRE ALARM CONTROL PANEL ACCLAIM SERIES 10 Fire Alarm Panel provides many flexible choices from basic conventional (non-addressable) panel to advance hard-wire addressable panel / systems. The ACCLAIM SERIES 10 Fire Alarm Panel provides many flexible, user friendly features that overcome the limitations found in today s conventional fire alarm systems. Its Performance, Reliability, Versatility and Unique Features greatly improve operational efficiency and productivity. Various upgrade options are available to enhance the fire alarm system such as: Features: #1.Auxiliary Status and Control Module provides addition indicators and control switches to be added to the panel for easy identification and control

5 The Alarm Verification Feature greatly reduces the disruption caused by unwanted false alarms. The LCD Display Unit automatically records the fire and alarm events with date and time, eliminating inaccurate or missing records due to human errors. Networking facility of the LCD Unit allows up to 32 panels to be networked and monitored from one centralized location. Zone (and device address, if hardwire addressable option is implemented) can be identified from the Main Alarm Panel thus reducing response time. Graphic User Interface guides duty staff to area in alarm in the shortest time possible. The Graphics User Interface also records events with date, time and operator information. The event storage capacity is only limited by the capacity of the hard disk of the PC. Various reports can be generated for post event analysis to help ACCLAIM SERIES 10 FIRE EXTINGUSHING CONTROL PANEL Acclaim Advance Fire Extinguishing Panel provides many flexible choices from basic conventional (non-addressable) panel to advance hard-wire addressable panel / systems. The basic conventional panels are available from 1 to 136 zones. The designis compact, attractive, user friendly and highly scalable. The panels are built with well proven solid state technology for long term cost effectiveness. operation and maintenance of the panel are provided with general frontal indications and color coded switches. The specific fault indications are mounted behind the front indications. It is able to work with most water / gas extinguishing system (FM200, Inert gas, CO2 & water mist etc.) and comes complete with Cross Zone Detection, Voting Logic Circuit (option), two digit countdown display and multiple zones with individual or common firing circuit. Features: Ease of use : Simple one touch operation, easy to learn and reduces errors Alarm interlocks : General sounder silencing and system resetting for system with multiple zone panel Facilities : Two digit timer countdown display, remote / local manual release & abort functions, 1st & 2nd alarm auxiliary output etc. Solid state detection technology Local manufacturer support : System designed and supported locally by highly experienced support team Compliance : BS EN 54 Parts 2 & 4 :1998, SS CP-10:2005 Approval : PSB approved (1 to 136 zones)

6 AS10-ICM8-1 8 WAY INDICATOR/CONTROL MODULE The AS10-ICM8-1, 8 way Indicators / Control Module is utilized in the range of Fire / Extinguishing Control Panel as an extended function for monitoring of remote status and controlling of additional auxiliary outputs. The V5-ICM8- is integrated with circuitry for the buzzer resound function upon monitoring status activation and the reminding buzzer function upon auxiliary control switch activation. AS10-ACM-1: 8 WAY CONTROL MODULE The AS10-ACM-1 8 way Control Module is utilized in the range of Fire / Extinguishing Control Panel as an extended function for controlling of additional auxiliary output. The AS10-ACM-1 is integrated with circuitry for the reminding buzzer function upon auxiliary control switch activation. Each auxiliary control switch can be operated either disable function as standard or manual start/stop function as option. Individual switch LED indicator is provided to notify the activation of the switch status. AS10-ATM-1: 8 WAY AUXILARY TERMINATION MODULE The AS10-ATM-1 is an 8 way Auxiliary Termination Module. It is utilized as an extension of Auxiliary Outputs to control Auxiliary Services; Lift / Fan / Sliding Door, etc. and alarm signal interfacing to Building Management System (BMS). The AS10-ATM-1 is provided with field selectable jumpers to select required type of output signal individually. It is usually connected to front 8 ways Auxiliary Control Module ACM for disable function or manual start/stop function respectively. AS10-SIM-1 :8 WAY STATUS INDICATOR MODULE The AS10-SIM-1 8 way Status Indicators Module is utilized in the range of Fire / Extinguishing Control Panel as an extended function for monitoring of remote status. The AS10-SIM-1 is integrated with circuitry for the buzzer resound function upon monitoring status activation. The V5-SIM-1 module is utilized as a front module and it is usually connected to the Status Termination Module AS10-STM-1 / Selectable Status Termination Module V5-SSTM-1.Ribbon connectors are provided for connection to the other system modules, this facilitates ease for installing and replacing of module. AS10-SSTM-1 : 8 WAY SELECTABLE STATUS TERMINATION MODULE The AS10-SSTM-1 is an 8 way Selectable Status Termination Module. It is utilized as an extension module to remote monitor the status such as Sprinkler Water Tank High Level / Low Level status, Pump Run / Stop status, Damper Open / Close status, Smoke Curtain Up / Down status etc. The AS10-SSTM-1 is provided with field selectable jumpers to select required type of input signal individually, Normally Open/ Normal Close signal. It is usually connected to front 8 ways Status Indicators Module SIM to indicate the status of remote monitoring status activation signal.

7 AS10-ASM2-1 :ALARM/AUXILAURY SUPERVISORY MODULE ACCLAIM SERIES 10 The AS10-ASM2-1 Alarm / Auxiliary Supervisory Module is utilized as an extension of alarm bell output or is employed as additional auxiliary output supervision when required. The AS10-ASM2-1 is provided with 2 alarm outputs, integrated with line open / short supervision circuitry complete with specific fault indicators provided for each output. EOLR (6.8K Ohm) resistor is required to be terminated at last device and polarized bells/auxiliary equipment shall be used for line open/short fault monitoring. Line Te-off s connection is not permitted. AS10-RTM-1 :16 WAY REPEATER TERMINATION MODULE The AS10-RTM-1 is a 16 way Repeater Signal Termination Module. It is utilized in the Fire Alarm Control Panels (FAP) to repeat Zone / Status alarm signal to Repeater panel. Transient surge voltage and over voltage protection circuitry is also incorporated for each repeat alarm signal. It is usually connected to front Zone Detection Module ZDM / Status Indicators Module SIM to repeat Zone / Status alarm signal to Repeater panel. AS10-LIM-1 24 WAY LCD INTERFACING MODULE The AS10-LIM-1 is a 24 way LCD Interfacing Module, to communicate with LCD Event Logging Module LLM for Alarm event signal. It is utilized as an extension module in Fire Alarm Panel (FAP) and Extinguishing Control Panel (ECP). It can also be utilized as Detector Address Point Termination Module in Hardwire Addressable System. The AS10-LIM-1 (Main) is applied for first 24 alarm signal interfacing and the V5-LIM-1 (Sub) is applied as an extension for subsequence module after first 24 alarm signal interfacing. AS10-LLM-1: LCD EVENT LOGGING MODULE LCD Event Logging Module (LLM) is utilized in the Fire / Extinguishing Control Panel as an add on feature to display and record the activated alarm zone information complete with date and time. LLM is integrated with non-volatile memory (EEPROM) to store and record the activated alarm zone event up to 999, it will not be lost even the system total power failure. LLM is also incorporated with backup battery for real time clock, it will be continuous running during the system total power failure. AS10-PSM-2: POWER SUPPLY MODULE The AS10-PSM-2 is a Power Supply Module work together with external step down transformer to supply power to the system. Self diagnosis function circuitry is incorporated to monitor AC Mains failure, supply output low/high voltage fault, battery disconnect fault, battery low/high voltage fault and charger/battery fuse blown fault complete with specific fault indicators provided. The V5-PSM-2 is integrated with voltage regulator circuit and protection circuit for over current, mains surge/over voltage, battery short and battery reverse connection.

8

9 AS10 LOOP DEVICES SLV-E(J) PHOTO ELECTRIC SMOKE DETECTOR Hochiki's new Photoelectric Detector incorporates a redesigned smoke chamber with 'Flat 'Response Technology 'enabling it to be equally sensitive to a wider range of combustible materials,thus removing the need for Ionisation Detectors in the majority of applications. New Chamber designed to reduce unwanted alarms and flat response smoke chamber consists of an LED and photo diode arrangement. The chamber is easily removed or replaced for cleaning and utilizes an unique baffle design which allows smoke to enter chamber whilst keep out ambient light. SLV-24N PHOTOELECTRIC SMOKE DETECTOR The SLV-24N can be used in all areas where Photoelectric Smoke Detectors are required. The patented smoke chamber makes the SLV-24N well suited for fires ranging from smouldering to flaming fires. NS-4 Series, NS-6 Series, HSC-4R or HSC-xxx R Style bases may be used with the SLV-24N. Current interchangeable/compatible devices are the SIJ-24 ionization detector, the SLR-24H photoelectric detector with heat sensor, and the DCD-135/190 heat detectors. DFJ-90E : Fixed-Temperature Heat Detector The DFJ Fixed Temperature Heat Detector is suited for installation where high heat output fires are expected or in areas where ambient condition would not allow the use of other detection methods (e.g. the presence of steam or cooking fumes such as in a boiler room or kitchen). Consideration should be given to the maximum normal operating temperature before deciding on the most appropriate DFJ detector for the application.

10 DFG-60E CONVENTIONAL WEATHER PROOF HEAT DETECTOR Model DFG-60E is a 60 C Fixed Temperature Waterproof Heat Detector, the detector uses a bi-metallic strip to sense temperature change, therefore consuming minimal standby current and providing high reliability. The DFG-60E is particularly suited to environments, which are exposed to high levels of condensation or are hosed down. The detector has a wide operating margin allowing it to respond to both slow and fast increases in temperature; it can also sense temperature KAC MCP1A: INDOOR CALL POINT Installation time and ultimately cost, are of paramount importance to any fire or security installer. The MCP range directly reflects this need by providing a unique plug and play concept designed specifically to reduce installation time. All new MCP products utilize a special terminal block, where all initial installation cabling is terminated. This terminal block is then simply connected to the back of the MCP. Simple, but effective, with no retermination required and no time wasted. KAC WCP1A-R470SG OUTDOOR CALL POINT The outdoor WCP is an IP67 sealed manual call point product. The enhanced environmental protection allows the unit to be installed in many external environments where water and dirt are likely to be present, making it a true waterproof and outdoor product. Installation time and ultimately cost, are of paramount importance to any fire or security installer. The WCP range directly reflects this need by providing a unique plug and play concept designed specifically to reduce installation time. All new WCP products utilise a special terminal block, where all initial installation cabling is terminated. MBA-6 KOBISHI ALARM BELL An aluminium die cast housing covers the operating part of this bell. Therefore the bell is suitable for both indoor and outdoor applications. A high quality micro-motor serves as the operating part. It provides reliable performance and an extremely long lifetime is assured. The micro-motor operates with a low starting voltage and very low current consumption. Use with Model: BBX-4 back box for a complete weatherproof application SYS-STR-FIRE RED BODY STROBE WITH CLEAN LEN & FIRE The System Sensor line of notification devices offers the most flexible and easy-to-use line of horns, strobes, and horn strobes in the industry. With white and red housing, universal fire symbol and a ceiling mount accessory available these devices can meet virtually any application. They also mount to a wide variety of back box sizes to offer the most flexibility in installation. This line of devices features a wide variety of features that simplifies installations. The mounting plate allows the devices to be compatible with a wide range of back box sizes. Settings for the strobe and horn are done using easy to set rotary switches on the back of the device.

11 s Information contained in this data sheet is up-to-date and correct as at the date of issue. As ACCLAIM cannot control or anticipate the conditions under which this product may be used, each user should review the information in specific context of the planned use. To the maximum extent permitted by law, ACCLAIM will not be responsible for damages of any nature resulting from the use or reliance upon the information contained in this data sheet. No express or implied warranties are given other than those implies mandatory by law. 171 Kaki Bukit Avenue 1 Shun Li Industrial Park Singapore Tel : Fax :

PAT E N T System 88. COMPLIES WITH Singapore Standard : SS CP10 : 2005 British Standard : BS EN54-2 : 1998 BS EN54-4 : 1998 REV.00

PAT E N T System 88. COMPLIES WITH Singapore Standard : SS CP10 : 2005 British Standard : BS EN54-2 : 1998 BS EN54-4 : 1998 REV.00 PAT E N T System 88 COMPLIES WITH Singapore Standard : SS CP10 : 2005 British Standard : BS EN54-2 : 1998 BS EN54-4 : 1998 REV.00 Pg 1 of 12 CONTENTS 1. GENERAL 1.1 Introduction 2 1.2 System Description

More information

16.34 Multiplex Fire Alarm System Construction Standards Page 1 of 5

16.34 Multiplex Fire Alarm System Construction Standards Page 1 of 5 Construction Standards Page 1 of 5.1 General Description.1 The University requires that all new fire alarm system control panel, components, and devices, as required for the project, be Secutron 2900 Series

More information

HART XL High Sensitivity Smoke Detection

HART XL High Sensitivity Smoke Detection High Sensitivity Smoke Detection The Hart XL High Sensitivity Smoke Detection system (HSSD) is an aspirating fire detection system designed to give very early indication of an incipient fire condition.

More information

MINERVA. Marine. Fire Detection. MX T2000 Panel Range. Features: MINERVA Marine Panel Range

MINERVA. Marine. Fire Detection. MX T2000 Panel Range. Features: MINERVA Marine Panel Range Fire Detection MINERVA Marine MX T2000 Panel Range Features: Enhances fire detection and eliminates unwanted alarms using fuzzy logic Assists fire fighting and training by providing on-screen risk management

More information

Conventional Releasing Control Panel

Conventional Releasing Control Panel s Data Sheet Fire Safety Products Conventional Releasing Control Panel Pre-Action Deluge Agent-Releasing Fire System Model TXR-320 Remote configurable Up to two (2) hazard areas Operable with the following:

More information

Overview. Wireless Overview QLD NSW VIC Fundamentals. Operation. Features.

Overview. Wireless Overview QLD NSW VIC Fundamentals. Operation. Features. Wireless Overview www.incitefire.com.au Overview Fundamentals FIREwave is a wireless based family of products which is fully integrated into Hochiki s renowned ESP intelligent hardwired system. This seamless

More information

INTELLIGENT FIRE TECHNOLOGY. Twinflex and Multipoint V3. User Guide (TO BE RETAINED BY USER) Issue 3

INTELLIGENT FIRE TECHNOLOGY. Twinflex and Multipoint V3. User Guide (TO BE RETAINED BY USER) Issue 3 INTELLIGENT FIRE TECHNOLOGY Twinflex and Multipoint V3 User Guide (TO BE RETAINED BY USER) 26-0340 Issue 3 Rafiki Protection Limited Rafiki policy is one of continual improvement and the right to change

More information

System 800 Addressable Fire Detection & Alarm System

System 800 Addressable Fire Detection & Alarm System SECTION 5: page 1 Section 5: System 800 Addressable Fire Detection & Alarm System SECTION 5: page 3 10 reasons to specify 800 1 Plug and Play A user friendly panel not requiring special software tools

More information

Specification/ Data Sheet

Specification/ Data Sheet Specification/ Data Sheet TRITON RP Agent Release Control Panel FEATURES Agent Release Control Panel designed specifically for suppression release operation with: Four initiating device circuits (IDCs)

More information

ZX1e ZX2e ZX5e. Document No Issue 01 user manual

ZX1e ZX2e ZX5e. Document No Issue 01 user manual ZX1e ZX2e ZX5e Document No. 996-130 Issue 01 user manual MORLEY-IAS ZX2E/ZX5E Fire Alarm Control Panels Table of Contents 1 INTRODUCTION... 4 1.1 NOTICE... 4 1.2 WARNINGS AND CAUTIONS... 4 1.3 NATIONAL

More information

MINERVA MZX125 Digital Addressable Fire Detection System

MINERVA MZX125 Digital Addressable Fire Detection System DATASHEET MINERVA MZX125 Digital Addressable Fire Detection System The Minerva MZX125 is a highly featured digital addressable panel with a comprehensive but easy to operate user interface. The system

More information

Installation and user manual for the FX range of fire panels. 1, 2, 4 and 8 zone panels

Installation and user manual for the FX range of fire panels. 1, 2, 4 and 8 zone panels Installation and user manual for the FX range of fire panels 1, 2, 4 and 8 zone panels Contents Panel installation 3 Panel connections 3 Wiring connection drawings 4 Panel facilities 6 Installation check

More information

HART XL High Sensitivity Smoke Detection

HART XL High Sensitivity Smoke Detection High Sensitivity Smoke Detection Hart XL High Sensitivity Smoke Detection (HSSD) TM is a smoke detection system that is simple to install, commission, service and use yet remains brilliantly capable in

More information

Conventional Fire Alarm System 2014 V1.2

Conventional Fire Alarm System 2014 V1.2 Conventional Fire Alarm System 2014 V1.2 Product Overview Control Panel 2 Conventional Fire Panel GST102A 2 zone Fire panel GST104A 4 zone Fire panel GST108A 8 zone Fire panel GST116A 16 zone Fire Panel

More information

intelligent fire alarm ID60series panels

intelligent fire alarm ID60series panels intelligent fire alarm ID60series panels features LPCB approved to EN54 Parts 2 and 4 One loop capacity (99 sensors and 99 modules) 16 fire zones, 16 non fire zones Supports advanced detection such as

More information

TECHNICAL DATA OBSOLETE

TECHNICAL DATA OBSOLETE Deluge Devices 270a 1. PRODUCT NAME VIKING PAR-3 Available since 1991 2. MANUFACTURED FOR: THE VIKING CORPORATION 210 N. Industrial Park Road Hastings, Michigan 49058 U.S.A. Telephone: (269) 945-9501 (877)

More information

Installation and user manual for the CF5000, MF5000 and FXP5000 range of fire panels

Installation and user manual for the CF5000, MF5000 and FXP5000 range of fire panels CF5000, MF5000 and FXP5000 Installation and user manual for the CF5000, MF5000 and FXP5000 range of fire panels 16 zone panels Contents PANEL INSTALLATION...3 Installation...3 PANEL WIRING... 3 Mains power

More information

four Vigilon Compact Analogue Addressable Fire Detection & Alarm System 4/1

four Vigilon Compact Analogue Addressable Fire Detection & Alarm System 4/1 four Vigilon Compact Analogue Addressable Fire Detection & Alarm System 4/1 ANALOGUE FIRE DETECTION VIGILON COMPACT FEATURES & BENEFITS four Keep it Simple All Vigilon devices connect onto the same 2

More information

TECHNICAL DATA. Humidity: 85% Relative Humidity (non-condensing) at 90 F (32 C) maximum.

TECHNICAL DATA. Humidity: 85% Relative Humidity (non-condensing) at 90 F (32 C) maximum. September 29, 1997 Firecycle III 433 a 1. PRODUCT NAME VIKING Model E-1 Manufactured 1997 Present 2. MANUFACTURED FOR THE VIKING CORPORATION 210 N Industrial Park Road Hastings, Michigan 49058, U.S.A.

More information

ID50series. intelligent fire alarm panels

ID50series. intelligent fire alarm panels ID50series intelligent fire alarm panels features LPCB approved to EN54 parts 2 and 4 One loop capacity (99 sensors and 99 modules) 16 fire zones, 16 non fire zones Supports NOTIFIER advanced range of

More information

5000 INSTALLATION GUIDE

5000 INSTALLATION GUIDE 5000 INSTALLATION GUIDE Table of Contents Section Page No 1. INTRODUCTION... 3 2. WARNINGS AND CAUTIONS... 3 3. UNPACKING... 3 4. INSTALLATION... 4 5. CONTROL PANEL - REMOVING ITEMS BEFORE MOUNTING...

More information

Hi, welcome to the topic on Fire Detection and Alarm Systems. This topic forms one of the critical knowledge areas for prospective fire safety

Hi, welcome to the topic on Fire Detection and Alarm Systems. This topic forms one of the critical knowledge areas for prospective fire safety Hi, welcome to the topic on Fire Detection and Alarm Systems. This topic forms one of the critical knowledge areas for prospective fire safety manager. As the appointed fire safety manager for a premise,

More information

LF-4000 Series Conventional Fire Alarm Control Unit

LF-4000 Series Conventional Fire Alarm Control Unit LF-4000 Series Conventional Fire Alarm Control Unit Features: 1 to 36 Zone Control Panels Control Key Switch Easy Push Button Control Switches Zone Circuit Monitoring for Open and Short Sounder Circuit

More information

CSP-204 CSP-208 CSP-104 CSP-108

CSP-204 CSP-208 CSP-104 CSP-108 Fire Alarm Control Panel CSP-204 CSP-208 CSP-104 CSP-108 Operation manual Firmware version 1.1 csp-x_o_en 06/15 SATEL sp. z o.o. ul. Budowlanych 66 80-298 Gdańsk POLAND tel. 58 320 94 00 www.satel.eu CONTENTS

More information

Architect s Project Number of 12 Fire Alarm/Smoke Detection Systems District Master Specs 2013 Edition

Architect s Project Number of 12 Fire Alarm/Smoke Detection Systems District Master Specs 2013 Edition PART 1 GENERAL 1.1 SECTION INCLUDES SECTION 28 31 00 FIRE ALARM AND SMOKE DETECTION SYSTEMS A. Fire alarm and smoke detection systems 1.2 REFERENCES A. NFPA 72 B. NFPA 101 1.3 REGULATORY REQUIREMENTS A.

More information

TABLE OF CONTENTS GENERAL... 2 A. DEFINITIONS DIGITAL, ADDRESSABLE FIRE ALARM SYSTEM... 2

TABLE OF CONTENTS GENERAL... 2 A. DEFINITIONS DIGITAL, ADDRESSABLE FIRE ALARM SYSTEM... 2 Division 28 ELECTRONIC SAFETY AND SECURITY TABLE OF CONTENTS 28 0000 GENERAL... 2 A. DEFINITIONS...2 28 3111 DIGITAL, ADDRESSABLE FIRE ALARM SYSTEM... 2 A. DESIGN REQUIREMENTS...2 B. CONSTRUCTION REQUIREMENTS...2

More information

PWGSC Ontario MULTIPLEX FIRE ALARM SYSTEM Sect Region Project Page 1 Number R

PWGSC Ontario MULTIPLEX FIRE ALARM SYSTEM Sect Region Project Page 1 Number R Region Project Page 1 PART 1 - GENERAL 1.1 REFERENCES.1 CAN/ULC-S524-2006, Standard for the Installation of Fire Alarm Systems..2 CAN/ULC-S525-2007, Audible Signal Device for Fire Alarm Systems..3 CAN/ULC-S526-2007,

More information

AEGIS FEATURES DESCRIPTION. Conventional Fire Alarm-Suppression Control Unit. Effective: March Programmable Relays

AEGIS FEATURES DESCRIPTION. Conventional Fire Alarm-Suppression Control Unit. Effective: March Programmable Relays AEGIS Conventional Fire Alarm-Suppression Control Unit FEATURES Agency Approvals FM Approved FM Approved to ANSI/UL 864, 9th edition FM Approved to ULC-S527-99 Other domestic U.S. approvals/listings pending/

More information

Project No Belleville Fire Hall/Headquarters and Emergency Operations Centre Section Belleville, Ontario Page 1 of 10

Project No Belleville Fire Hall/Headquarters and Emergency Operations Centre Section Belleville, Ontario Page 1 of 10 Belleville, Ontario Page 1 of 10 1 GENERAL 1.1 GENERAL REQUIREMENTS.1 The General Conditions of CCDC2-2008, and the General requirements of Division 1, form part of this Section and must read in conjunction

More information

Operating instructions SENTRI4 Control panel based Fire detection and alarm system

Operating instructions SENTRI4 Control panel based Fire detection and alarm system 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 30 32 Zones Healthy 15:45 Fault Power Fault System Fault SenTRI 4 Fire System Designed to EN54 Pt 2 & 4 Operating instructions

More information

Vigilant MX4428 Fire Alarm System

Vigilant MX4428 Fire Alarm System Vigilant MX4428 Fire Alarm System The Vigilant MX4428 is an intelligent fire alarm system, incorporating Tyco MX TECHNOLOGY to provide advanced, analogue addressable fire detection. It features support

More information

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION Fike s CyberCat 254 (P/N 10-066) is a state-of-the-art true intelligent digital peer-to-peer modular fire alarm control system.

More information

BT1 SINGLE ZONE FIRE ALARM SYSTEM OPERATORS MANUAL

BT1 SINGLE ZONE FIRE ALARM SYSTEM OPERATORS MANUAL BT1 SINGLE ZONE FIRE ALARM SYSTEM OPERATORS MANUAL 26 Aug 2015 V1.8 Page 1 SECTION CONTENTS PAGE NO. 1.0 SYSTEMS DESCRIPTION 1.1 General descriptions 2 1.2 Master Alarm PCB 2 1.3 Zone Display Board 2 1.4

More information

The CWSI System CALL WITH QUESTIONS. RELY ON OUR KNOWLEDGE. DEPEND ON OUR EXPERIENCE. (800)

The CWSI System CALL WITH QUESTIONS. RELY ON OUR KNOWLEDGE. DEPEND ON OUR EXPERIENCE. (800) The CWSI System The CWSI wireless fire alarm product line offers system versatility like none other. Frequency Hopping Spread Spectrum Technology (FHSS), coupled with Bi-directional RF Communication, Repeater

More information

DS7400Xi Addressable Control/ Communicator

DS7400Xi Addressable Control/ Communicator DS7400Xi Addressable Control/ Communicator DS7400Xi DS7400Xi-EXP 110VAC operation 220VAC operation Remotely Programmable WDSRP (Windows Detection Systems Remote Programming Software), allows the systems

More information

The EN54 Part 2, 4 and 13 Fire System

The EN54 Part 2, 4 and 13 Fire System Scope of work: To design, supply, install and commission an Analogue Addressable Fire Alarm Control System in accordance with the details specified herein and in accordance with supplied drawings The EN54

More information

Matrix2000. User Guide - CPD Advanced Analog Fire Alarm Control Panel 4 24 Zones. Version: 2.0 Revision: 1

Matrix2000. User Guide - CPD Advanced Analog Fire Alarm Control Panel 4 24 Zones. Version: 2.0 Revision: 1 Matrix2000 User Guide - CPD Advanced Analog Fire Alarm Control Panel 4 24 s Version: 2.0 Revision: 1 IMPORTANT INFORMATION Limitation of liability It is mandatory, Matrix2000 panel to be installed in accordance

More information

TECHNICAL DATA SHEET CONVENTIONAL FIRE ALARM SYSTEMS Conventional Fire Alarm Control Panel

TECHNICAL DATA SHEET CONVENTIONAL FIRE ALARM SYSTEMS Conventional Fire Alarm Control Panel CVENTIAL ALARM S Features: Description: The LF-CP Series Fire Alarm Control Panel is manufactured based on advanced technology while maintaining high quality during assembly. It is of solid state circuitry

More information

ID2000. intelligent fire alarm panel

ID2000. intelligent fire alarm panel ID2000 6pp A4 10-01 3/8/06 22:57 Page 1 ID2000 intelligent fire alarm panel features Certified to EN54 Parts 2 and 4 Expandable from 2 to 8 loop capacity Up to 198 devices per loop (99 sensor and 99 modules)

More information

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION Fike s Cheetah Xi 50 (P/N 10-071) is a state-of-the-art true intelligent digital peer-to-peer modular suppression control system.

More information

Consultant Specification AGILE Wireless Fire Detection System

Consultant Specification AGILE Wireless Fire Detection System Contents Scope of Work... 2 The EN54 Part 2 & 4 Fire System... 2 Standards... 2 Wireless Intelligent Photoelectric Smoke Detector Specification... 4 Wireless Intelligent Thermal Heat Detector Specification...

More information

AND ARCHITECT SPECIFICATIONS

AND ARCHITECT SPECIFICATIONS SXL Conventional Zone Fire Alarm Control Panel ENGINEER AND ARCHITECT SPECIFICATIONS 4 Zones Expandable to 8 Zones Microprocessor Based Control Factory Programmed Field Configurable 2 Style Y Notification

More information

ED820-24V MODEL INSTRUCTION MANUAL. fire DETECTOR

ED820-24V MODEL INSTRUCTION MANUAL. fire DETECTOR ED820 24V MODEL fire DETECTOR INSTRUCTION MANUAL Address: Enigma House, Enigma Business Park, Malvern, Worcestershire, WR14 1GD Tel: 44 (0)1684 891500 Fax: 44 (0)1684 891600 Email: sales@electronicdevices.co.uk

More information

"SS90" SERIES CONTROLS MODEL C INSTALLATION MANUAL

SS90 SERIES CONTROLS MODEL C INSTALLATION MANUAL S S S SS O L I D S S90 TATE ECURITIES, INC SOLID STATE FAIL-SAFE UNIT * PATENT PENDING LISTED U L 99Y9 RESET RELEASING DEVICE SOLID STATE SECURITIES, INC. "SS90" SERIES CONTROLS MADE IN THE U.S.A. MODEL

More information

SECTION FIRE ALARM AND SMOKE DETECTION SYSTEMS

SECTION FIRE ALARM AND SMOKE DETECTION SYSTEMS PART 1 GENERAL 1.1 SECTION INCLUDES A. Fire alarm and smoke detection systems 1.2 REFERENCES A. NFPA 72 B. NFPA 101 1.3 REGULATORY REQUIREMENTS A. System: UL listed B. Conform to requirements of NFPA 101

More information

ZP3 Operator & Maintenance Manual Version 1

ZP3 Operator & Maintenance Manual Version 1 ZP3 Operator & Maintenance Manual Version 1 Introduction Thank you for selecting Clymac Ltd. Clymac can provide maintenance for the system, emergency call out, telephone support and any modifications required

More information

The EN54 Part 2 & 4 Fire System

The EN54 Part 2 & 4 Fire System Scope of work: To design, supply, install and commission an Analogue Addressable Fire Alarm Control System in accordance with the details specified herein and in accordance with supplied drawings The EN54

More information

Electric Release Panel Wiring Tips

Electric Release Panel Wiring Tips R IPS CARBO STEEL PIPE FIRE PROTECTIO PRODUCTS Electric Release Panel Wiring Tips 30.4 VICTAULIC IS A ISO 900 CERTIFIED COMPAY Model PDRP-00 Releasing Panels are compact single enclosure units containing

More information

For Complete Fire and Gas Solutions

For Complete Fire and Gas Solutions Industrial Fire For Complete Fire and Gas Solutions 2 The Total Package What do you need from an integrated fire and gas system? In industrial fire and gas environments it s important to have a reliable

More information

Syncro AS. Analogue Addressable Fire Control Panel. User Manual

Syncro AS. Analogue Addressable Fire Control Panel. User Manual Syncro AS Analogue Addressable Fire Control Panel User Manual Man-1100 Issue 02 Nov. 2008 Index Section Page 1. Introduction...3 2. Safety...3 3. Panel Controls...4 3.1 Access Level 1...4 3.2 Access Level

More information

Fire Alarm Control Panel CFP-16 OPERATION, INSTALLATION & PROGRAMMING MANUAL AUSTRALIAN EDITION. 26/05/2015 Rev D DOC

Fire Alarm Control Panel CFP-16 OPERATION, INSTALLATION & PROGRAMMING MANUAL AUSTRALIAN EDITION. 26/05/2015 Rev D DOC Fire Alarm Control Panel CFP-16 OPERATION, INSTALLATION & PROGRAMMING MANUAL AUSTRALIAN EDITION 26/05/2015 Rev D DOC-01-022 Documentation Feedback Your feedback helps us keep our documentation up to date

More information

Control Panel. 1.0 GENERAL SCOPE OF WORK Introduction... 2

Control Panel. 1.0 GENERAL SCOPE OF WORK Introduction... 2 Architectural & Engineering Specifications Control Panel 1.0 GENERAL... 2 1.1 SCOPE OF WORK... 2 1.1.1 Introduction... 2 1.2 GENERAL CONDITIONS... 2 1.2.1 After-Sales Support... 2 1.2.2 Quality assurance...

More information

Data Sheet Fire Safety & Security Products. System Overview. Initiating Circuits SXL-EX FACP 7906

Data Sheet Fire Safety & Security Products. System Overview. Initiating Circuits SXL-EX FACP 7906 s Data Sheet Fire Safety & Security Products SXL-EX Fire Alarm Control Panel Conventional Zone Fire Alarm Control Panel ARCHITECT AND ENGINEER SPECIFICATIONS Four (4) zones expandable to eight (8) zones

More information

3.1 Introduction. 3.1 Introduction

3.1 Introduction. 3.1 Introduction DEPARTMENT OF ARCHITECTURE ABUBAKAR TAFAWA BALEWA UNIVERSITY, BAUCHI ARC 624: ADVANCED BUILDING SERVICES LESSON 3: FIRE DETECTION AND ALARM SYSTEMS IN BUILDINGS 3.1 Introduction 3.1 Introduction 3.2 Conventional

More information

MINERVA MX. 800 Series Ancillary Equipment

MINERVA MX. 800 Series Ancillary Equipment An extensive range of ancillary modules has been specifically designed for use with the MX range of Fire Controllers. The 800 range of ancillary modules provide the MX Fire Controller with a wide degree

More information

FTEN1, FTEN2, & FTEN4 1, 2 & 4 ZONE FIRE DETECTION AND ALARM CONTROL PANELS

FTEN1, FTEN2, & FTEN4 1, 2 & 4 ZONE FIRE DETECTION AND ALARM CONTROL PANELS QUICK USER GUIDE FOR, 2 & 4 ZONE PANELS INDICATORS COLOUR INDICATION MON FAULT Yellow On when a fault condition has occurred, or if no other fault Led is on, this indicates 24v auxiliary fuse failure.

More information

SYSTEM MANUAL FT1-SB. Single Zone Fire Alarm System

SYSTEM MANUAL FT1-SB. Single Zone Fire Alarm System SYSTEM MANUAL FT1-SB Single Zone Fire Alarm System DOCUMENT HISTORY Issue Date Description Written By Checked By Draft 0 2/9/2008 Original Document. A. Shenouda C. Orr Issue 1 4/11/2011 Update drawing

More information

CONVENTIONAL >FIRE DETECTION C400 SYSTEM FIRE DETECTION

CONVENTIONAL >FIRE DETECTION C400 SYSTEM FIRE DETECTION FIRE DETECTION >FIRE DETECTION CONVENTIONAL C400 SYSTEM FIRE DETECTION EFFICIENT AND MODULAR Elkron fire detection systems protect your business and grow with it Elkron's conventional fire detection range

More information

SPECIFICATION MICROMIST FIRE SUPPRESSION SYSTEM WITH SHP-PRO CONTROL PANEL

SPECIFICATION MICROMIST FIRE SUPPRESSION SYSTEM WITH SHP-PRO CONTROL PANEL SECTION 1 - GENERAL CONDITIONS I. SCOPE: This specification outlines the requirements for a Fike Micromist Water Mist Fire Suppression System with automatic detection and control. The work described in

More information

CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM

CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION Fike s Cheetah Xi (P/N 10-068) is a state-of-the-art true intelligent digital peer-topeer modular suppression control system. It is ideal for

More information

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL PRODUCT Specification FEATURES Designed To Meet The Requirements Of EN54 Expandable From 1 To 5 Loops As Standard A Variety Of Networking Options

More information

The new detector from Rafiki

The new detector from Rafiki The new detector from Rafiki Three smoke detectors Three heat detectors Combined smoke/heat detector Full alarm sounder Strobe End-of-line device/loop isolator Rafiki s Multipoint ASD detector range have

More information

FIRE ALARM SYSTEM FRCME AMS R2M SOM CZM DIMM. Serial. Annunciator. Printer ATG-EA ALK-V. Duct Detector SLC (DCP) Notification Alarm Equipment

FIRE ALARM SYSTEM FRCME AMS R2M SOM CZM DIMM. Serial. Annunciator. Printer ATG-EA ALK-V. Duct Detector SLC (DCP) Notification Alarm Equipment FIRE ALARM SYSTEM AMS FRCME Printer R2M SOM CZM DIMM ATG-EA Serial Annunciator ALK-V Duct Detector Notification Alarm Equipment SLC (DCP) Notification Alarm Equipment Printer (RS-232) COMMS (RS-485) EOLR

More information

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information)

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) AL802ULADA NAC Power Extender Installation Guide (See Application Guide for additional information) Rev. 042010 Agency Listings: UL Listed Control Units for Fire Protective Signaling Systems (UL 864).

More information

Fire detection and alarm system Operating instructions

Fire detection and alarm system Operating instructions Fire detection and alarm system Operating instructions Operating instructions Table of Contents User responsibility - - - - - - - - - - - - 4 Daily - - - - - - - - - - - - - - - - - - - 4 Weekly - - -

More information

TABLE OF CONTENTS TABLE OF CONTENTS 1

TABLE OF CONTENTS TABLE OF CONTENTS 1 TABLE OF CONTENTS TABLE OF CONTENTS 1 FEATURES 2 Keypad Programmable... 2 EEPROM Memory... 2 Static/Lightning Protection... 2 Supervision... 2 Operation... 2 SPECIFICATIONS 2 PC1550 Control Panel... 2

More information

MS-4012/4024 and CMS-4012/4024. Instruction Manual for the. Fire Alarm Control Panels

MS-4012/4024 and CMS-4012/4024. Instruction Manual for the. Fire Alarm Control Panels R 12 Clintonville Road, Northford, CT 06472 Phone: (203) 484-7161 FAX: (203) 484-7118 Instruction Manual for the MS-4012/4024 and CMS-4012/4024 Fire Alarm Control Panels Document 15586 5/11/93 Revision:

More information

Datasheet. Dry-pipe Vacuum Sprinkler System, Electric Release Self contained unit. Features. FIREFLEX VACTEC description

Datasheet. Dry-pipe Vacuum Sprinkler System, Electric Release Self contained unit. Features. FIREFLEX VACTEC description FIREFLEX VACTEC description This FIREFLEX VACTEC integrated fire protection system consists of a vacuum system trim totally pre-assembled, prewired and factory tested. All electrical and mechanical components

More information

OSU PROJECT NO PAGE 1 02 NOV 2006 SECTION FIRE ALARM SYSTEM

OSU PROJECT NO PAGE 1 02 NOV 2006 SECTION FIRE ALARM SYSTEM OSU PROJECT NO. 30-04-15 PAGE 1 PART 1 GENERAL 1.1 WORK INCLUDED A. Provide all labor, materials, and equipment required to provide a complete and operating system of manual and automatic detection devices,

More information

The ID51 & ID52 can be upgraded to 2 loops without the need to change back box. FEATURES. Intelligent Features

The ID51 & ID52 can be upgraded to 2 loops without the need to change back box. FEATURES. Intelligent Features 990-052, Issue 6 20 March 2006 ID50 Series Single Loop Intelligent Fire Alarm Panels Section: Intelligent Fire Alarm Panels GENERAL The NOTIFIER ID50 series single loop intelligent fire alarm panels, has

More information

FS-1600 Fire Alarm Panel

FS-1600 Fire Alarm Panel FS-1600 Fire Alarm Panel Operation, Installation & Programming Manual Revision A 30th August 2013 ECN13-0060 Manufactured by: Approvals: Australian Standard AS 7240.2-2004 Australian Standard AS 7240.4-2004

More information

Control Panel User Guide

Control Panel User Guide Fire Detection & Alarm System Control Panel V4.14 Control Panel User Guide (TO BE RETAINED BY USER) 26-0397 Issue 6 Fike s policy is one of continual improvement and the right to change a specification

More information

Intelligent addressable fire alarm control panel

Intelligent addressable fire alarm control panel Intelligent addressable fire alarm control panel Input current consumption: Panel rating: Batteries: Networking and Interfaces Panel to panel communication: Number of panels: Interface port: System capacity

More information

Commercial and Light Industrial Fire Alarm Control Panel

Commercial and Light Industrial Fire Alarm Control Panel FireSystem 2000 Commercial and Light Industrial Fire Alarm Control Panel Features Easily expandable. All new plug-in board design Two supervised audible circuits Lamp and system trouble circuit test Ground

More information

ALK-V PHOTOELECTRIC SMOKE SENSOR

ALK-V PHOTOELECTRIC SMOKE SENSOR ALK-V PHOTOELECTRIC SMOKE SENSOR APPLICATION The HOCHIKI America ALK-V Photoelectric Smoke Sensor is particularly suited to detecting optically dense smoke typical of fires involving materials such as

More information

FireNET Series - ANALOG ADDRESSABLE FIRE ALARM CONTROL PANEL

FireNET Series - ANALOG ADDRESSABLE FIRE ALARM CONTROL PANEL FireNET Series - ANALOG ADDRESSABLE FIRE ALARM CONTROL PANEL The FireNET 427 control panel is an analog addressable fire alarm panel containing 2 or 4 SLC loops with each loop supporting 27 devices of

More information

SALES SUPPORT DOCUMENT

SALES SUPPORT DOCUMENT SALES SUPPORT DOCUMENT ML-322 MAXLOGIC CONVENTIONAL FIRE EXTINGUISHING CONTROL PANEL ML-322 series operates on cross-zone principle, has 4 detection zones and one extinguishing release output which is

More information

ID3000 intelligent. fire alarm panel

ID3000 intelligent. fire alarm panel ID3000 intelligent fire alarm panel features introduction certified to EN54 parts 2 and 4 The NOTIFIER ID3000 intelligent fire alarm panel offers a technically sophisticated range of facilities and functions

More information

AL600ULADA. NAC Power Extender. Installation Guide

AL600ULADA. NAC Power Extender. Installation Guide AL600ULADA NAC Power Extender Installation Guide Rev. 122000 AL600ULADA - NAC Power Extender Overview: The Altronix AL600ULADA is an extremely cost effective 6.5 amp voltage regulated remote power supply/battery

More information

PANELS, KEYPADS & MODULES. Take Fire Protection to the Next Level Fire Products from DSC

PANELS, KEYPADS & MODULES. Take Fire Protection to the Next Level Fire Products from DSC Take Fire Protection to the Next Level Fire Products from DSC AFD2000 Addressable Fire Control Panel Series Provides Maximum Flexibility The new AFD2000 is a completely programmable series of addressable,

More information

Installation Manual CFP-105. Fire Alarm Control Panel. Version 1.0

Installation Manual CFP-105. Fire Alarm Control Panel. Version 1.0 CFP-105 Fire Alarm Control Panel Installation Manual Version 1.0 WARNING: This manual contains information on limitations regarding product use and function and information on the limitations as to liability

More information

AL1042ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev X

AL1042ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev X AL1042ULADA NAC Power Extender Installation Guide (See Application Guide for additional information) Rev. 071508X Agency Listings: UL Listed for Control Units for Fire Protective Signaling Systems (UL

More information

THE "SS90" SERIES RELEASE DEVICES MODEL B2 INSTALLATION MANUAL

THE SS90 SERIES RELEASE DEVICES MODEL B2 INSTALLATION MANUAL S S S S S S S S 90 OLID TATE ECURITIES, INC SOLID STATE FAIL-SAFE UNIT * PATENT PENDING LISTED U 99Y9 RESET L RELEASING DEVICE SOLID STATE SECURITIES, INC. THE "SS90" SERIES RELEASE DEVICES MADE IN THE

More information

CONTENTS Installation Precautions... 1 Chapter 1 Product Introduction... 2 Chapter 2 Technical Specifications... 3

CONTENTS Installation Precautions... 1 Chapter 1 Product Introduction... 2 Chapter 2 Technical Specifications... 3 CONTENTS Installation Precautions... 1 Chapter 1 Product Introduction... 2 Chapter 2 Technical Specifications... 3 2.1 Electrical Specifications... 3 2.2 Communication Loop Parameters... 3 2.3 Dimensions...

More information

ID3000 intelligent. fire alarm panel

ID3000 intelligent. fire alarm panel ID3000 intelligent fire alarm panel features certified to EN54 parts 2 and 4 expandable from 2 to 8 loop capacity up to 198 per loop (99 sensor and 99 modules) 255 fire zones per panel modular design supports

More information

intelligent solutions

intelligent solutions Alco is one of the leading intelligent solution providers of Fire Detection System. Security System and Public Addressing System in the United States of America. Based in California since 1992, we have

More information

MINERVA MZX125. Digital Addressable Fire Detection System

MINERVA MZX125. Digital Addressable Fire Detection System A C C E S S C O N T R O L C C T V E A S R F I D F I R E P R O T E C T I O N I N T R U D E R A L A R M S DATA SHEET MINERVA MZX125 Digital Addressable Fire Detection System Features: Long term service and

More information

ADR Analog Addressable Fire Alarm Control Panel. Technical Manual. Control Panels. 3000En. En pdf

ADR Analog Addressable Fire Alarm Control Panel. Technical Manual. Control Panels. 3000En. En pdf Control Panels Analog Addressable Fire Alarm Control Panel Technical Manual TELEFIRE FIRE & GAS DETECTORS LTD PO Box 7036 Petach Tikva 49250 Israel Tel: 972 3 970 0400 Fax: 972 3 921 1816 email: Web: info@telefire.co.il

More information

MR-2602 Two Zone Fire Alarm Control Panel

MR-2602 Two Zone Fire Alarm Control Panel MR-2602 Two Zone Fire Alarm Control Panel Installation Manual Secutron LT-2015 Rev.3 July 2010 Table of Contents 1 Introduction 1.1 The MR-2602 Fire Alarm Control Unit... 11 1.1.1 General features...

More information

MX4428. Addressable Fire Alarm System. Features. Advantages & Options

MX4428. Addressable Fire Alarm System. Features. Advantages & Options MX4428 Addressable Fire Alarm System Features // Supports MX Series devices including the 850 Series Generation 6 Multi-Sensor analogue addressable detector range // SMARTSENSE and MX FASTLOGIC (fuzzy

More information

Precept Marine Control Panel Application Guide

Precept Marine Control Panel Application Guide Precept Marine Control Panel Application Guide Contents Page 1.0 Cabinet Specifications 2 2.0 Panel Hardware Specifications 5 3.0 Panel Configuration 8 4.0 Technical Specifications 8 5.0 Battery Sizes

More information

TABLE OF CONTENTS. FOR THE RECORD 15 PROGRAMMING WORK SHEETS 16 CONTROL PANEL WIRING DIAGRAM inside back cover

TABLE OF CONTENTS. FOR THE RECORD 15 PROGRAMMING WORK SHEETS 16 CONTROL PANEL WIRING DIAGRAM inside back cover TABLE OF CONTENTS FEATURES 2 SPECIFICATIONS 2 INSTALLATION 3 Mounting the Panel... 3 Mounting the Keypad... 3 Auxiliary Power Connection... 3 PGM Terminal Connections... 3 Bell/Siren Connection... 3 Keypad

More information

ELECTRONIC SOUNDER STROBE Model : AVD-C407

ELECTRONIC SOUNDER STROBE Model : AVD-C407 ELECTRONIC SOUNDER STROBE Model : AVD-C407 MULTRON range of combination Electronic Sounders with Strobe Lights are designed to complement our Fire Alarm products both technically and aesthetically as an

More information

Fire Alarm Control Panel. System Maintenance and Log Book

Fire Alarm Control Panel. System Maintenance and Log Book Fire Alarm Control Panel System Maintenance and Log Book Fire Alarm System Maintenance A fire alarm system must provide early and reliable warning of the outbreak of fire. To achieve this, the system remains

More information

INTELLIGENT FIRE ALARM CONTROL PANEL

INTELLIGENT FIRE ALARM CONTROL PANEL INTELLIGENT FIRE ALARM CONTROL PANEL FX-2000 SERIES Description Mircom s FX-2000 Series Intelligent Analog Fire Alarm Control Panel is designed to provide maximum flexibility of analog system requirements

More information

Across-the-Line SERIES MP300 Combined Manual and Automatic

Across-the-Line SERIES MP300 Combined Manual and Automatic Across-the-Line SERIES MP300 Combined Manual and Automatic Metron Fire Pump Controllers conform to the latest requirements of National Fire Protection Association s Standard for Centrifugal Fire Pumps

More information

BSR Addressable Fire Detection control panel. Installation operation manual

BSR Addressable Fire Detection control panel. Installation operation manual BSR-1116 Addressable Fire Detection control panel Installation operation manual ATTENTION!!! READ THE MANUAL BEFORE THE INSTALLATION AND PAY ATTENTION TO PARAGRAPH 2.6.3 AND 2.6.4. Page 2 from 36 Contents

More information

IntelliKnight 5820XL Addressable Fire Alarm Control System Sales Guide

IntelliKnight 5820XL Addressable Fire Alarm Control System Sales Guide IntelliKnight 5820XL Addressable Fire Alarm Control System Sales Guide Product Overview The IntelliKnight 5820XL is an intelligent addressable fire alarm control panel designed for flexibility and reliability.

More information

Soft Start Series MP700 Solid State, Reduced Voltage

Soft Start Series MP700 Solid State, Reduced Voltage Metron Fire Pump Controls and Accessories Soft Start Series MP700 Solid State, Reduced Voltage Metron Fire Pump Controllers conform to the latest requirements of National Fire Protection Association s

More information

SPECIFICATION MICROMIST FIRE SUPPRESSION SYSTEM WITH CHEETAH Xi 50 CONTROL PANEL

SPECIFICATION MICROMIST FIRE SUPPRESSION SYSTEM WITH CHEETAH Xi 50 CONTROL PANEL SECTION 1 - GENERAL CONDITIONS I. SCOPE: This specification outlines the requirements for a Fike Micromist Water Mist Fire Suppression System with a Cheetah Xi 50 addressable detection and control system.

More information