Fire Product Catalog

Size: px
Start display at page:

Download "Fire Product Catalog"

Transcription

1 Additional Expansion Modules Fire Product Catalog CLEVER FIRE SOLUTIONS MA 1000 / Analog Addressable Fire Alarm Panel 1

2 Military Industry Public Buildings Industrial & Commercial Company Profile We are a dynamic company introducing clever uninterrupted fire detection solutions. Our highly accurate products are designed to protecting lives and property and abide by strict international standards. Owing to our highly experienced engineering know-how, we offer design flexibility to suit the simplest to complex multi-building site installations.

3 Hospitality Industry High-Tech Industry MTech s diverse product range offers advanced fire protection devices with a wide range of sensory elements and interfacing features for a complete central system: Our sophisticated and compact control analog and conventional panels interface with protocols of leading fire detection systems on the market today. Our intelligent addressable fire alarm systems can program multiple addresses and recall old addresses for future use. Our sensory technology minimizes unnecessary alarms without sacrificing prompt activation, with intelligently discriminating devices that can discriminate between fire and non- threatening or deceptive conditions. MTech s interdisciplinary research and design team is made up of engineers with over twenty years of combined experience in all aspects of fire detection and gas extinguishing systems, providing us with flexible and short turnaround time design advantages. Our knowledgeable multi-lingual staff provides services that include training and on-site consultation and technical support. MTech is positioned with a global reach, having had its fire systems installed in complex multi-building sites such as hospitals, airports, hotels, banks and shopping centers, as well as military and high tech industries around the world, namely the Middle East, Russia, Eastern Europe, and India.

4 Our Core Values: Be the first to introduce clever and cost-effective uninterrupted fire detection solutions to improve life and property safety Invest in our experienced multi-lingual team who provide training and on-site consultation and technical support and forge long term relationships with our customers Committed to leading-edge product research and development To be fully compliant with the latest international standards

5 Table of Contents The Analog Range Analog Addressable Fire Alarm Panel / P.8 Application Schematic for the MA-1000 / P.16 Addressable Beams & etectors / P.18 Addressable Sounders & Beacons / P.26 Addressable Loop evices: Interfaces / P.34 Call Points / P.46 The Conventional Range Conventional Fire Alarm Panel / P.50 Conventional etectors / P.52 Beam etectors / P.58 Call Points / P.62

6 PROUCTS Analog Addressable Fire Alarm Panel MA-1000 / P.8 Analog Expansion Panels MA-1000SUB Analog Sub Control Extension Panel / P.10 MA-1100 Power Booster / P.12 MA-1050 Remote Panel / P.14 MA Analog Range Typical Schematic / P.16 Addressable Beams & etectors MA-320 Optical Photoelectric Smoke etector / P.18 MA-330 Multi-Mode Heat Sensor / P.20 MA-340 Photo-Thermal Smoke Sensor / P.22 Mounting Bases: MA-300 Standard European Mounting Base / P.24 Addressable Sounders & Beacons MA-S Soft Addressed Wall Sounder / P.26 MA-SH Soft Addressed Wall Sounder / P.28 MA-BSH Addressable Sounder Beacon / P.30 MA-BS Addressable Sounder Base / P.32 Addressable Loop evices: Interfaces MA-TA T-Tap / P.34 MA-2I2OR Output Module / P.36 MA-OR Compact Single Channel Output / P.38 MA-IN Micro Single Channel Input Units / P.40 MA-Zone Compact Single Zone Input / P.42 MA-100 PRO Hand-Held Programmer / P.44 Call Points MA-CP Analog Call Point / P.46

7 MA Analog Fire Alarm System The MA Analog Range is a clever addressable fire alarm control system capable of interfacing with advanced brain protocols of leading fire detection systems on the market. Its flexible design makes the MA-1000 one of the most powerful and cost effective analog panels available, with quick response time and easy integration to support a wide range of commercial and industrial applications. The minimalistic design of the MA offers advanced functionality to support complex cause and effect programming for industrial, high-tech and military applications, as well as a wide range of public institutions such as hospitals, airports, universities, and others. MA 1000 / Analog Addressable Fire Alarm Panel

8 MA-1000 Analog Addressable Panel The MA-1000 panel is an intelligent analog addressable fire alarm control panel with a two-loop configuration, with a future option of a four-loop operation. The MA-1000 is suitable for a wide range of commercial and industrial applications, with a large capacity to support complex cause and effect programming and extensive range of user controllable functions. The MA-1000 panel uses spur tolerant soft addressing to minimize installation time and remove the potential for errors associated with manual addressing. It assigns multiple addresses and saves addresses of removed devices for future use without affecting the remaining devices. Offered with the MA-1000 is an analog sub-control extension panel, the MA-1000SUB, with multiple interfacing connections to the main panel. All of the MA fire detection system components operate as part of a fully integrated system with its panel, detectors, interfaces and other ancillaries in full compatibility with each other. The MA product series abide to UL864 9th Edition standards, and are in accordance with current standards of the Russian and Israeli Standards Associations. System Functionality Four row graphic display that provides a simple and comprehensive menu-driven end-user interface: 64-character backlit LC display (4 lines with 16 characters on each line) Holds up to 150 addressable devises per loop including a mixture of call points, detectors, interfaces, beacons and loop sounders. esigned to ensure future expansion: Even after the system has been programmed, the panel can allocate the next available address without altering any of the existing address number allocation. Uses soft addressing during commissioning: Addresses are locked until manually altered to enable simple system additions and deletions without affecting other addresses. Maintains full system integrity in the event of an external short-circuit fault: The panel s short circuit isolators on the devices nearest to each side of the short-circuit open to isolate a fault in the system and drives communication from both ends of the loop to sustain full communication with all system devices. Multiple stages and complex cause and effect programming: The panels are designed with a wide range of user controllable functions with three stages of cause-and-effect programming per output device to meet the needs of a wide range of small to large scale projects. Four programmable NAC s: The panel includes four programmable output NAC s with a maximum load of 1.2A. Programmable relays: The panel is designed with three programmable relays, one dedicated alarm relay, and one dedicated trouble relay. Power Supply: 6.5 amp Features: Two Class A Loops, with a future option of four loop operation Approved to UL864 9th Edition/ NFPA 2007 Compliant In accordance with Russian and Israeli fire standards Menu driven programming Soft addressing Up to 150 addressable devices per loop Short circuit isolators incorporated into each loop device Four programmable NAC s Three programmable relays One dedicated alarm relay One dedicated trouble relay RS232 and RS485 Easy to program Up to 16 panels on network 6.5 amp power supply 8 Analog Addressable Fire Alarm Panel / MA-1000

9 MA-1000 Analog Addressable Panel Panel Specifications: Standards Approved to UL864 9th Edition Model MA-1000 Number of loops 2 with a future option of 4-loop operation Programmable from PC Yes Network Yes Addresses per loop 150 Panel sounder circuits 4 O/P NAC s Programmable relays 3 Alarm relay 1 Trouble (fault) relay 1 Output ports RS 485 and RS 232 Mains input voltage 110 / 230VAC System operating voltage 24VC Battery Two 12V 7 Ah or Two 12V 12 Ah (dependent) Cable entries 4 top- entry 11 right side 2 left side Environmental operating temperature 0ºC - 49ºC Humidity 95% RH (non condensing) Color Red Weight 7 Kg imensions: MA-1000 H W H 370 (mm) 393 (mm) 112 (mm) W Order Codes: MA Loop Panel MA-1000 / Analog Addressable Fire Alarm Panel 9

10 MA-1000SUB Analog Sub Control Extension Panel The MA-1000SUB extension panel is an expansion module featuring four programmable NAC s, three programmable relays, two Class A loops, 150 addressable devices per loop, 6.5 amplifier, AC power supply and battery backup. Multiple MA-1000SUB extensions can be connected to the MA-1000 main panel with a network card, and the module is capable of independent operation in the event of network failure, transforming it into one of the most powerful analog panels on the market. Features: Standalone panel Internal LC display Four programmable NAC s Three programmable relays Two Class A loops Up to 150 addressable devices per loop 6.5 amp power supply Backup battery Menu driven programming Soft addressing Up to 126 panels onetwork 10 Analog Expansion Panels / MA-1000SUB

11 MA-1000SUB Analog Sub Control Extension Panel Panel Specifications: Number of loops Programmable from PC Network Addresses per loop Panel sounder circuits Programmable relays Alarm relay Trouble (fault) relay Output ports Mains input voltage System operating voltage Battery Cable entries 2 Yes Yes O/P NAC s RS 485 and RS / 230VAC 24VC Two 12V 7 Ah or Two 12V 12 Ah (dependent) 4 top-entry 1 right side 2 left side Environmental operating temperature Humidity Color Weight 0ºC - 49ºC 95% RH (non condensing) Red 7 Kg imensions: MA-1000SUB H W H 370 (mm) 393 (mm) 112 (mm) W Order Codes: MA-1000SUB 2-Loop Extension Panel MA-1000SUB / Analog Expansion Panels 11

12 MA-1100 Power Booster The MA-1100 power booster is a 4.5 amp notification power expander compatible with MTech s fire alarm control panels. Up to eight units can be installed on the main panel. Complete with its own AC power, battery charging circuit and backup battery, the MA has four fully programmable NAC s, three completely programmable relays, one fire relay and one alarm trouble relays. It is programmed through the main panel. Features: Installation of up to eight units on the main panel 4.5 amp power supply Backup battery Four programmable NAC s Three programmable relays One fire relay One alarm trouble relay 12 Analog Expansion Panels / MA-1100

13 MA-1100 Power Booster Panel Specifications: Programmable NAC s Programmable Relays Alarm Relay Trouble relay Power supply Programmable from PC Battery backup Output ports Mains input voltage System operating voltage Battery Cable entries amps Yes Yes RS 485 and RS / 230VAC 24VC Two 12V 7 Ah or Two 12V 12 Ah (dependent) 4 top-entry 1 right side 2 left side Environmental operating temperature Humidity Color Weight 0ºC - (-)49ºC 95% RH (non condensing) Red 7 Kg imensions: MA-1100 H W H 370 (mm) 393 (mm) 112 (mm) W Order Codes: MA-1100 Power Booster MA-1100 / Analog Expansion Panels 13

14 MA-1050 Remote Annunciator The main control panel has a built-in annunciator with a four line, 64-character backlit LC display with easy to understand system messages and a user-friendly membrane keypad. It additionally supports up to eight remote annunciators with matching control and display layout with two levels of user codes to limit operating system programming to authorized personnel only. The built-in annunciator also has five system status LEs for Alarm, Supervisory, Trouble, Silence and AC power. The Reset and Silence buttons on the keyboard are noticeably larger than the rest. The annunciator enclosure can be surface or flush mounted. Features: 64-character backlit LC display (4 lines with 16 characters on each line) Membrane Keypad Accepts user codes or fire fighter s key (Optional) Larger Reset and Silence keypad buttons Eight remote installations per FACP RS-485 interface to panel On-board Piezo sounder audibly indicates Alarms, Troubles and Supervisories Five status LEs for Alarm, Supervisory, Trouble, Silence and AC power conditions 14 Analog Expansion Panels / MA-1050

15 MA-1050 Remote Annunciator Technical Specifications: Standards Model Maximum remote installations per FACP System Operating Voltage Standby Current Alarm Current Wiring istance Environmental Operating Temperature Humidity NFPA 72; UL864 MA V dc 12 ma max 30 ma 3,300 max. from FACP (depending on wire gauge and number of devices on the RS-485) 0ºC-49ºC 10% 93% non-condensing imensions: H W W H 120 (mm) 200 (mm) 50 (mm) Order Codes: MA-1050 Remote Annunciator MA-1050 / Analog Expansion Panels 15

16 Typical Schematic: MA Analog Range Up to 126 panels, 252 loop, address, 1008 MA-1100 (9072 nac adress and relays) MA-1000 Two Class A Loops Menu driven programming Soft addressing Up to 150 addressable devices per loop 4 programmable NAC s 3 programmable relays 1 dedicated alarm relay 1 dedicated trouble relay RS232 and RS485 Up to 16 panels on network MA-BSH MA-1050 Up to 8 panels per local panel NAC 1 NAC 2 MA-1000 NAC 3 MA-110 LOOP-2 NAC 4 RS-485 RS232 LOOP-1 MA-TA MA-3I3O MA-320 MA-320 MA-212OR MB-PBR CLEVER FI MB-220 MB Analog Addressable Fire Alarm Panel / MA 1000

17 MA-1100 Installation of up to eight units on the main panel 4.5 amp power supply Backup battery Four programmable NAC s Three programmable relays One fire relay One alarm trouble relay RS232 and RS485 MA-1000SUB 2 Class A Loops Menu driven programming Soft addressing Up to 150 addressable devices per loop 4 programmable NAC s 3 programmable relays RS232 and RS485 Stand alone Up to 126 panels on network MB-FL Blower 1 RL MA-1050 Up to 8 panels per local panel Up to 150 devices per loop RL RL MA-1000SUB LOOP-2 RS-485 MB-LI LOOP-1 MA-340 MA-330 MA-320 MA-IN MA-CP MA-OR MA-Zone RE SOLUTIONS MB-240 MB-230 MB-220 MB-PBR MA 1000 / Analog Addressable Fire Alarm Panel 17

18 MA-320 Optical Photoelectric Smoke Analog etector The MA-320 is an optical photoelectric smoke detector designed to operate with the MA analog range with advanced features. Overview The optical sensor operates on low current and has built-in short circuit isolators in each unit. The MA-320 gives the fastest response to slow burning or smoldering fires that give rise to visible smoke particles. The sensor is soft addressed, suitable for most applications, and its advanced LE design offers 360 views. The photoelectric smoke sensor is easy to install and service with cable entry into the base from the rear or side, and removable detector chamber. Features: Built-in short circuit isolators Soft addressed Single address LE design with 360 view rift compensation Positive lock indication Two second start-up and reset time Illuminates continuously under fire conditions Benefits: Quick and simple to install Removable detector chamber Wiring via common mounting base Easy to service Operates on low current Aesthetically pleasing low profile design 18 Addressable Beams & etectors / MA-320

19 MA-320 Optical Photoelectric Smoke Analog etector Technical Specifications: etector head MA-320 Base MA-300 Working voltage VC Voltage waveform Filtered C +/- 1v max 120 Hz Standby current (average) 220µA Alarm current (maximum) 5 ma Relay current (maximum) N/A Start-up time 2 seconds Sensitivity / % /ft Sensitivity use checker No-Climb TRUTEST UL Listing 77TL Heat element rating N/A Reset time (maximum) 2 seconds Heat detector spacing N/A Ambient temperature (maximum) F Mounting position Ceiling in open areas Compatibility identifier imensions: ia ia (excluding base) (including base) 101 (mm) 33 (mm) 45 (mm) Installation Highlights: Easy Fitting: Sensors are fixed and wired via common mounting base (MA-300 ordered separately). Easy Access: Cable entry into the base can be from the rear or side. Locking Facility: This feature can activate if required, to prevent unauthorized sensor removal without the use of a special tool. User Interface: The LE indicates the status of the detector, can be set to flash to confirm communication with the control panel, and illuminates continuously under fire conditions. All wiring connections are via a common mounting base (ordered separately). Order Codes: MA-320 Optical Photoelectric Smoke etector MA-320 / Addressable Beams & etectors 19

20 MA-330 Multi-Mode Heat Sensor The MA-330 is a multi-mode heat sensor designed to operate with the MA analog range, with advanced features. Overview The MA-330 multi-mode heat sensor operates on low current, has built-in short circuit isolators, and can be set at three modes 135 F, 194 F and rate of rise. These sensors are designed to provide reliable fire detection especially in environments with high levels of dust, fumes, steam or smoke, conditions that may set-off false alarms. The multi-mode heat sensor is easy to install and service with cable entry into the base from the rear or side, and removable detector chamber. Features: Three setting modes Built-in short circuit isolators Soft addressed Single address Led design with 360 view rift compensation Positive lock indication Two second start-up and reset time Illuminates continuously under fire conditions Benefits: Quick and simple to install Removable detector chamber Wiring via common mounting base Easy to service Aesthetically pleasing low profile design 20 Addressable Beams & etectors / MA-330

21 MA-330 Multi-Mode Heat Sensor Technical Specifications: etector head MA-330 Base MA-300 Working voltage VC Voltage waveform Filtered C +/- 1v max 120 Hz Standby current (average) 220µA Alarm current (maximum) 5 ma Relay current (maximum) N/A Start-up time 2 seconds Sensitivity / % /ft Sensitivity use checker No-Climb TRUTEST UL Listing 77TL Heat element rating 135F ROR + Fixed * 194F Fixed** Reset time (maximum) 2 seconds Heat detector spacing 50 ft Ambient temperature (maximum) F, F (194 F setting) Mounting position Ceiling in open areas Compatibility identifier imensions: ia ia (excluding base) (including base) 101 (mm) 43 (mm) 45 (mm) Installation Highlights: Easy Fitting: Sensors are fixed and wired via common mounting base (MA-300 ordered separately). Easy Access: Cable entry into the base can be from the rear or side. Locking Facility: This feature can activate if required, to prevent unauthorized sensor removal without the use of a special tool. User Interface: The LE indicates the status of the detector, can be set to flash to confirm communication with the control panel, and illuminates continuously under fire conditions. All wiring connections are via a common mounting base (ordered separately). Order Codes: MA-330 Multi-Mode Heat Sensor MA-330 / Addressable Beams & etectors 21

22 MA-340 Photo-Thermal Smoke Sensor The MA-340 is a photo-thermal smoke sensor designed to operate with the MA analog range with advanced features. Overview The MA-340 photo-thermal smoke sensor operates on a low current, and uses combined photo and thermal signals to respond quickly to fast clean burning and smoldering fires. The sensor s thermal enhancement provides a higher alarm threshold and improves rejection of many common causes of false alarm. The photo-thermal smoke sensor is easy to install and service with cable entry into the base from the rear or side, and removable detector chamber. It has built-in short circuit isolators, and offers 360 LE views. Features: Higher alarm threshold Combined photo and thermal signals Built-in short circuit isolators Soft addressed Single address LE design with 360 view rift compensation Positive lock indication Two second start-up and reset time Illuminates continuously under fire conditions Benefits: Quick and simple to install Removable detector chamber Wiring via common mounting base Easy to service Operates on low current Aesthetically pleasing low profile design 22 Addressable Beams & etectors / MA-340

23 MA-340 Photo-Thermal Smoke Sensor Technical Specifications: etector head MA-340 Base MA-300 Working voltage VC Voltage waveform Filtered C +/- 1v max 120 Hz Standby current (average) 220µA Alarm current (maximum) 5 ma Relay current (maximum) N/A Start-up time 2 seconds Sensitivity / % /ft Sensitivity use checker No-Climb TRUTEST UL Listing 77TL Heat element rating 135 F Reset time (maximum) 2 seconds Heat detector spacing 50 ft (heat alone operation) Ambient temperature (maximum) F Mounting position Ceiling in open areas Compatibility identifier imensions: ia ia (excluding base) (including base) 101 (mm) 43 (mm) 45 (mm) Installation Highlights: Easy Fitting: Sensors are fixed and wired via common mounting base (MA-300 or MA-301 ordered separately). Easy Access: Cable entry into the base can be from the rear or side. Locking Facility: This feature can activate if required, to prevent unauthorized sensor removal without the use of a special tool. User Interface: The LE indicates the status of the detector, can be set to flash to confirm communication with the control panel, and illuminates continuously under fire conditions. All wiring connections are via a common mounting base (ordered separately). Order Codes: MA-340 Multi-Mode Heat Sensor MA-340 / Addressable Beams & etectors 23

24 MA-300 Standard Addressable Mounting Base The MA-300 is a standard addressable European base designed for the detector series of the MA analog range. Overview The MA-300 mounting base has special features to ensure proper installation and usage, with positive lock indication signaling that the sensor is fitted correctly and integral sensor shorting link that allows for simple wiring termination when a sensor is removed. The MA-300 base is easily installed, with multiple cable entry points. It is designed with a dedicated earth terminal, and separate terminals for loop in and loop out connections (each terminal can accept up to two 2.5mm cables). Features: Integral sensor shorting link Positive lock indication Side cable entry Separate loop in and loop out terminals edicated earth terminal Benefits: Easy to install Simple to terminate wiring Multiple cable entry points Easy to maintain 24 Addressable Beams & etectors / MA-300

25 MA-300 Standard Addressable Mounting Base Technical Specifications: Type Color imensions Standard European Mounting Base White (ia x ) 104mm x 22mm imensions: ia ia 104 (mm) 22 (mm) Installation Highlights: Terminals Separate terminals for loop in and loop out connections. edicated earth terminal. Each terminal can accept up to two 2.5Mm cables. Base Cable entry at rear. Stand-off feature to prevent distortion when mounted on an uneven surface. esigned with breakouts to enable the sensor base to sit neatly over surface run cables. Fixings suitable for standard BESA box or direct fixing to a suitable surface. Mounting etector ifficulties: If you have trouble mounting the detector, check: The wiring move or shorten wires if needed. The surface - reposition the base so that it is not mounted on an exceptionally uneven surface. Order Codes: MA-300 Standard European Mounting Base MA-300 / Addressable Beams & etectors 25

26 MA-S Wall Sounder The MA-S is a loop-powered soft addressed wall sounder for internal use, with advanced features. It is designed to operate with the MA analog range. Overview The MA-S offers excellent sound output levels while maintaining low current consumption. The high efficiency design of these intelligent addressable wall sounders offer excellent sound output levels despite the low current consumption. The addressable sounder is designed with a choice of different tones and volume levels. It is easy to install (surface mounted) and has built-in short circuit isolators. Weatherproof versions also available. Features: Built-in short circuit isolators Soft addressed Single address Loop powered High efficiency design Simple clip fixing assembly Weatherproof versions also available Benefits: Fitted base for easy installation Low current consumption Selectable tones controlled by the panel Adjustable volume controlled by the panel Easy to maintain 26 Addressable Sounders & Beacons / MA-S

27 MA-S Wall Sounder Technical Specifications: escription Standards Operating voltage Standby current Tones (set by panel) Sound output at +/-3db (set by panel) Operating temperature Humidity (non condensing) Color Weight Ingress protection Cable entry MA-S Wall Sounder (for internal and outdoor use) UL864 9th Edition en54 17V dc to 32V dc < 320µA Continuous: 984Hz Pulsed: 984Hz / 0Hz pulse 1Hz Two tone: 644 / 984Hz at 1Hz cycle Slow whoop: Hz in 3.5 seconds/0.5secs Low volume: 87dB at < 2mA Medium volume : 93dB at < 3mA High volume: 100dB at < 6mA -10 C to +55 C 0 to 95% RH Red 0.25kg IP42 and also available in IP65 Rear/side imensions: W H H Internal Sounder 105 (mm) 105 (mm) 95 (mm) Outdoor Sounder 108 (mm) 108 (mm) 103 (mm) W Installation Highlights: Install the base to the mounting surface using two fixing holes. Fix cables - cable entry can be rear or side. Make connections to connector block on main sounder body. Clip the main body of the sounder into position (on base) the body locks into position when pressed home. Volume is set by fire control panel (no need to access sounder to alter settings). Tone is set by fire control panel (no need to access sounder to alter setting). o not use high voltage testers if ANY equipment is connected to the system. Screen (Earth) must be continuous along entire length of loop. Order Codes: MA-S MA-S Outdoor Addressable Wall Sounder (for internal use) Addressable Wall Sounder (for outdoor use) MA-S / Addressable Sounders & Beacons 27

28 MA-SH Wall Sounder Beacon The MA-SH is a loop-powered soft addressed wall sounder beacon for internal use with advanced features. It is designed to operate with the MA analog range. Overview The MA-SH offers excellent sound output levels while maintaining low current consumption. The high efficiency design of these intelligent addressable wall sounders offer excellent sound output levels despite the low current consumption. The addressable MA-SH sounder beacon is easy to install (surface mounted) and maintain. It has built-in short circuit isolators. The MA-SH can also accommodate a high powered LE beacon (optional) that provides both audible and visual alarm signals. Weatherproof versions also available. Features: Built-in short circuit isolators Soft addressed Single address Loop powered High efficiency design Simple clip fixing assembly High output LE beacon available Weatherproof versions also available Benefits: Fitted base for easy installation Low current consumption Selectable tones controlled by the panel Adjustable volume controlled by the panel Easy to maintain 28 Addressable Sounders & Beacons / MA-SH

29 MA-SH Wall Sounder Beacon Technical Specifications: escription Standards Operating voltage Standby current Tones (set by panel) Sound output (set by pane) at +/-3dB Flash energy Operating temperature Humidity (non condensing) Color Lens color Weight Ingress protection Cable entry Cable size / type MA-S Wall Sounder (for internal and outdoor use) UL864 9th Edition en54 17V dc to 32V dc < 320µA Continuous: 984Hz Pulsed: 984Hz / 0Hz pulse 1Hz Two tone: 644 / 984Hz at 1Hz cycle Slow whoop: Hz in 3.5 seconds/0.5secs gap Low volume: 92dB at < 6.5mA Medium volume: 97dB at < 7.5mA High volume: 100dB at < 8.5mA 1Hz -10 C to +55 C 0 to 95% RH Red Red 0.21kg 0.32kg IP42 and also available in IP65 Rear/side 0.5mm to 2.5mm/ FIRETUF, FP200 or MICC imensions: W H H Internal Sounder 105 (mm) 105 (mm) 95 (mm) Outdoor Sounder 108 (mm) 108 (mm) 103 (mm) W Order Codes: MA- SH MA-SH Outdoor Addressable Wall Sounder (for internal use) Addressable Wall Sounder (for outdoor use) MA -SH / Addressable Sounders & Beacons 29

30 MA-BSH Sounder Beacon Base The MA-BSH is a sounder beacon base for soft addressed sensors and also functions as a standalone device. It is designed to operate with the MA analog range with advanced features. Overview The MA-BSH is an intelligent addressable sounder beacon base with tone selection and volume adjustment offering excellent sound output levels while maintaining low current consumption. It has single point connection for sensors, sounders and beacons. The addressable MA-BSH sounder beacon base is easy to install (surface mounted) and maintain. It has built-in short circuit isolators. The MA-BSH can also accommodate a high powered LE beacon (optional) that provides both audible and visual alarm signals. This MA-BSH has dual functionality as a sensor mounting base (for a sensor to be fitted directly to the base), or alternatively, as a dedicated discreet standalone device (with this option, a special cover plate is placed on the base). Features: Built-in short circuit isolators Soft addressed Single address Loop powered High efficiency design Simple clip fixing assembly High output LE beacon available Can be used as a sounder beacon base or as a standalone sounder beacon Cover plate (optional) Benefits: Fitted base for easy installation Low current consumption Selectable tones controlled by the panel Adjustable volume controlled by the panel Single point connection for sensor, sounder and LE beacon (saves time and installation costs) Easy to maintain 30 Addressable Sounders & Beacons / MA-BSH

31 MA-BSH Sounder Beacon Base Technical Specifications: escription Standards Operating voltage Standby current Tones (set by panel) Sound output at +/-3dB (set by panel) Operating temperature Humidity (non condensing) Color Weight Ingress protection MA-BSH Sounder Beacon Base UL864 9th Edition 17V dc to 32V dc < 320µA Continuous: 910Hz Pulsed: 910Hz / 0Hz pulse 1Hz Two tone: 610 / 910Hz at 1Hz cycle Slow whoop: Hz in 3.5 Seconds Low volume : 77dB at < 6.6mA Medium volume : 89dB at < 8mA High volume : 90dB at < 9mA -10 C to +55 C 0 to 95% RH White 0.2kg IP40 imensions: ia 115 (mm) 44 (mm) ia Installation Highlights: Install the base to the mounting surface using two fixing holes. Fix cables - cable entry can be rear or side. Clip the main body of the sounder into position (on base) the body locks into position when pressed. Make connections via connector block on front of main sounder body. Fix sensor or cover plate on the sounder. The cover can be locked into place if required. Volume is set by fire control panel (no need to access sounder to alter settings). Tone is set by fire control panel (no need to access sounder to alter setting). o not use high voltage testers if ANY equipment is connected to the system. Screen (Earth) must be continuous along entire length of loop. Order Codes: MA-BSH Addressable Sounder Beacon Base MA-BSH / Addressable Sounders & Beacons 31

32 MA-BS Sounder Base The MA-BS is a sounder base for soft addressed sensors and also functions as a standalone device. It is designed to operate with the MA analog range with advanced features. Overview The MA-BS is an intelligent addressable sounder base with tone selection and volume adjustment offering excellent sound output levels while maintaining low current consumption. It has a single point connection for sensors and sounders. The addressable MA-BS sounder base is easy to install (surface mounted) and maintain. It has built-in short circuit isolators. This MA-BS has dual functionality as a sensor mounting base (for a sensor to be fitted directly to the base), or alternatively, as a dedicated discreet standalone device (with this option, a special cover plate is placed on the base). Features: Built-in short circuit isolators Soft addressed Single address Loop powered High efficiency design Simple clip fixing assembly Can be used as a sounder base or as a standalone sounder Cover plate (optional) Benefits: Fitted base for easy installation Low current consumption Selectable tones controlled by the panel Adjustable volume controlled by the panel Single point connection for sensor and sounder (saves time and installation costs) Easy to maintain 32 Addressable Sounders & Beacons / MA-BS

33 MA-BS Sounder Base Technical Specifications: escription Standards Operating voltage Standby current Tones (set by panel) Sound output at +/-3dB (set by panel) Operating temperature Humidity (non condensing) Color Weight Ingress protection MA-BS Sounder Base UL864 9th Edition 17V dc to 32V dc < 320µA Continuous: 910Hz Pulsed: 910Hz / 0Hz pulse 1Hz Two tone: 610 / 910Hz at 1Hz cycle Slow whoop Low volume : 84dB at < 4mA Medium volume : 92dB at < 8mA High volume : 95dB at < 12mA -10 C to +55 C 0 to 95% RH White 0.2kg IP40 imensions: ia 102 (mm) 40 (mm) ia Installation Highlights: Install the base to the mounting surface using two fixing holes. Fix cables - cable entry can be rear or side. Clip the main body of the sounder into position (on base) the body locks into position when pressed. Make connections via connector block on front of main sounder body. Fix sensor or cover plate on the sounder. The cover can be locked into place if required. Volume is set by fire control panel (no need to access sounder to alter settings). Tone is set by fire control panel (no need to access sounder to alter setting). o not use high voltage testers if ANY equipment is connected to the system. Screen (Earth) must be continuous along entire length of loop. Order Codes: MA-BS Addressable Sounder Base MA-BS / Addressable Sounders & Beacons 33

34 MA-TA T-Tap The MA-TA is a T-Tap interface designed for addressable devices operated with the MA Analog Range. This soft addressed compact interface is fitted with short circuit isolators to meet most design requirements. It is manufactured according to UL864 9th Edition standards, and abides with current standards of both the Russian and Israeli Standards Associations. Overview This compact interface is easy to install, and is designed to provide T-Tap wiring, a class B connection to system accessories. T-Tapping makes for a fast, error-free installation, and offers an opportunity for relatively low-cost system upgrades. Features & Benefits: Soft addressed Single address Built in short circuit isolators Compact design Easy to install Connects system accessories via Class B connection Makes for a fast and error-free installation A low-cost option for installing system upgrades 34 Addressable Loop evices: Interfaces / MA-TA

35 MA-TA T-Tap Technical Specifications: escription Standards EMC Quiescent current Cable size (Min-Max) IP rating Humidity Operating temperature MA-TA T-Tap Interface UL864 9th Edition CE marked 170μA 0.5 to 2.5mm² IP40 0 to 95% non condensing -10 C to +60 C imensions: H W W H 147 (mm) 88 (mm) 57 (mm) Installation Highlights: Cable earth screen must be connected to its earth adjacent earth terminal. No end of line resistor required. Typical Wiring Schematic. Order Codes: MA-TA T-Tap Interface MA-TA / Addressable Loop evices: Interfaces 35

36 MA-2I2OR (Two in Two out) Output Module The MA-2I2OR is an output module designed to operate with the MA Analog Range. This soft addressed compact interface is fitted with short circuit isolators to meet most design requirements. It is manufactured according to UL864 9th Edition standards, and abides with current standards of both the Russian and Israeli Standards Associations. Overview This compact interface is easy to install, and is designed to enable small individual applications of conventional fire detection to be fully integrated with a main analog addressable fire system. The output module accepts a one zone conventional detector and one zone manual call point. It has two sounder circuits* and one relay. *An external power supply is required, regulated for fire and current limited. Features: Soft addressed Single address Built in short circuit isolators Accepts a one zone detector Accepts a one zone manual call point Two sounder circuits One relay Benefits: Easy to install Compact design Makes it easy to expand a fire alarm system using existing wiring Reduced installation cost by using the 2 sounder circuits 36 Addressable Loop evices: Interfaces / MA-2I2OR

37 MA-2I2OR (Two in Two out) Output Module Technical Specifications: escription Standards Operating voltage Quiescent current Quiescent load current Alarm current Number input circuits Zone Circuit 1 Zone Circuit 2 Number of call points Call point resistance Zone Circuit 1 Zone Circuit 2 Number of detectors Short circuit fault threshold Open circuit fault threshold Number of sounder circuits Load per output Sounder circuit 1 and 2 EOL Fire relay single pole C/O Operating temperature Humidity (non condensing) Color Ingress protection MA-2I20 Output Module UL864 9th Edition 15V dc to 30V dc 3.4mA (max) 2.8mA (max) 8mA (max) 2 Call points only etectors and call points Unlimited 470Ω to 680Ω EOL 6K8 EOL Active EOL 20 (max) 150Ω N/A active EOL 2 300mA (max) 12K 1A - 30V dc -10 C to +60 C 0 to 95% RH White IP40 imensions: H W H 147 (mm) 88 (mm) 60 (mm) W Installation Highlights: All connections are via heavy duty terminals. Cable entry can be top, bottom, side or rear. Can be surface or semi recessed mounted. Order Codes: MA-2I2OR Output Module MA-2I2OR / Addressable Loop evices: Interfaces 37

38 MA-OR Single Channel Output The MA-OR is an advanced and compact single channel output unit for a variety of interfaces, designed to operate with the MA Analog Range. This soft addressed compact interface is fitted with short circuit isolators to meet most design requirements. Overview The MA-OR single channel output is easy to install. The interface is suitable for switching low voltage (24V dc at 1A maximum), via a set of non latching relay contacts. It is also capable of switching HVAC (heating, ventilation, and air conditioning technologies) control circuits, plant shutdown control circuits, fire door closure, and the like. Features: Soft addressed Integral short circuit isolator Single address Non latching changeover relay contacts Suitable for switching low volts Capable of switching - HVAC control circuits - Plant shutdown - Fire door closure Benefits: Quick and simple to install No hard addressing required (Plug and play) Lightweight Compact size 38 Addressable Loop evices: Interfaces / MA-OR

39 MA-OR Single Channel Output Technical Specifications: escription Standards Operating voltage Quiescent current Switching voltage Contact rating Switching power Operating temperature Humidity (non condensing) Weight Ingress protection MA-OR Micro Single Channel Output Unit UL864 9th Edition 18V dc to 30V dc 310µA 24V dc to 30V dc 1A 30 Watts -10ºC to +60ºC 0 to 95% RH 0.078kg IP40 imensions: W H W H 35 (mm) 65 (mm) 18.5 (mm) Installation Highlights: Can be switched to 24V dc control circuits (such as fire door retainers and the like). Single strand fireproof cable up to 2.5mm² connections. Connect loop and output cable screen to interface with earth terminals. Change over, non-latching, non-monitored, volt free relay outputs. Automatic addressing (no addressing of the interface is required). Order Codes: MA-OR Single Chanel Output MA-OR / Addressable Loop evices: Interfaces 39

40 MA-IN Micro Single Channel Input Unit The MA-IN is a Micro single channel input unit designed to operate with the MA Analog Range. This soft addressed compact interface is fitted with short circuit isolators to meet most design requirements. Overview This compact dry contact input monitoring module is used to accept input signals from external equipment such as beam detectors, flow switches, valve monitor switches and the like. The MA-IN is easy to install and can hold up to 150 units per loop. Features: Soft addressed Single address Built in short circuit isolators Up to 150 units per loop Suitable for monitoring: - Beam detectors - Flow switches - Valve monitor switches Benefits: Easy to install Compact design Lightweight Compact size No hard addressing required 40 Addressable Loop evices: Interfaces / MA-IN

41 MA-IN Micro Single Channel Input Unit Technical Specifications: escription Standards Operating voltage Quiescent current Trigger resistance End of line resistor Short circuit fault threshold resistance Open circuit fault threshold resistance Operating temperature Humidity (non condensing) Weight Ingress protection Ma-In Micro Single Channel Input Units UL864 9th Edition 18V dc to 30V dc 310µA 5.6 KΩ 22KΩ 1KΩ 33KΩ -10ºc to +60ºc 0 to 95% RH 0.078kg IP40 imensions: W H W H 35 (mm) 65 (mm) 18.5 (mm) Installation Highlights: Connect loop and input cable screen to interface with earth terminals. Fit the end of line monitoring resistor at the end of the input wiring. If the input is unused, fit the end of line resistor at the interface input terminals. Inputs are monitored for open and short circuit fault conditions. Monitors normally open volt free contacts (such as flow switches, etc.). Suited for single strand fireproof cable up to 2.5mm². Order Codes: MA-IN Micro Single Channel Input Unit MA-IN / Addressable Loop evices: Interfaces 41

42 MA-Zone Input Monitor The MA-Zone is a compact single zone input monitor designed to operate with the MA Analog Range. This soft addressed compact interface is fitted with short circuit isolators to meet most design requirements. Overview The MA-Zone is a compact single zone input monitor, capable of interfacing with a zone of up to 20 conventional detectors on an analog fire panel. The module connects to addressable loop and acts as conventional slave under a single address. It will operate with any MTech conventional detectors and call point. Features: Soft addressed Integral short circuit isolator Takes on a single address Input monitored for open and short ground trouble Active end of line monitoring Accepts a zone of MTech conventional detector heads and call points Benefits: Quick and simple to install Easy to expand a system using existing wiring No external short circuit isolator required No hard addressing required (Plug and play) Lightweight Compact size 42 Addressable Loop evices: Interfaces / MA-ZONE

43 MA-Zone Input Monitor Technical Specifications: escription Standards Operating voltage Quiescent current Load with 20 detectors, and unlimited call points Alarm load with 20 detectors & unlimited call points etectors per zone End of line monitor Fire input trigger resistance Short circuit fault threshold resistance Open circuit fault threshold resistance Operating temperature Humidity (non condensing) Weight Ingress protection MA-Zone Input Monitor UL864 9th Edition 18V dc to 30V dc 2.6mA (nom) 3.2mA (nom) 8.0mA (nom) 20 (max) Active end of line unit - EOLM-1 680Ω (nom) 100Ω (max) 39KΩ (min) -10ºc to +60ºc 0 to 95% RH 0.28kg IP40 imensions: W H 35 (mm) 65 (mm) 18.5 (mm) W H Installation Highlights: Can be used with any MTech conventional detector. Maximum 20 detectors per zone. Connect loop and input cable screen to interface with earth terminals. Suited for single strand fireproof cable up to 2.5mm². Automatic addressing (no addressing of the interface is required). Order Codes: MA-ZONE Single Zone Input Monitor MA-ZONE / Addressable Loop evices: Interfaces 43

44 MA-100PRO Hand-Held Programmer The MA-100PRO is a hand-held programmer designed to operate with the MA Analog Range. The MA-100PRO is a versatile tool to aid the installation, commissioning, maintenance and servicing of advanced addressable devices and fire alarm systems. Overview Robust and lightweight, the MA-100PRO is easy to use and equipped with a user-friendly menu structure on a 2 40 character LC display. It is powered from a single PP3 size, heavy duty battery or an external supply. The Programmer has a built in addressable base as well as two external terminals to interface with other devices of the fire alarm system. Features: User-friendly menu 2 40 character LC display Provides address readings Writes addresses eletes addresses Reads analog values Programmes to 3 heat settings Benefits: Compact design Lightweight Tests other devices of the fire alarm system 44 Addressable Loop evices: Interfaces / MA-100PRO

45 MA-100PRO Hand-Held Programmer Technical Specifications: POWER: press to power up RESET: will return the unit to initial state EXIT: to escape from the menu ENTER: to executes the desired display function NEXT: to jump to next menu imensions: H W W H 215 (mm) 100 (mm) 45 (mm) Order Codes: MA-100PRO Hand-Held Programmer MA- 100PRO / Addressable Loop evices: Interfaces 45

46 MA-CP Analog Call Point MB-CPR and MB-CPY Call Points The MA-CP is an intelligent surface call point designed to operate with the MA Analog Range. This soft addressed compact interface is fitted with short circuit isolators to meet most design requirements. Overview The MA-CP is an advanced indoor analog manual call point, with an outdoor variant also available. The call point has a fragile glass element and a test key for ease of maintenance. The MA-CP also has plug and play terminal connections for fast wiring, and is resettable. It can be flush or surface mounted. Features: High visibility status LE Plug and play Heavy duty terminals Available in standard and weatherproof versions Benefits: Quick and simple to install Fast fit clip on front cover Easy to maintain (with key for test and cover removal) Flush or surface mounted 46 Addressable Loop evices: Interfaces / MA-CP

47 MA-CP Analog Call Point Technical Specifications: Model escription Standard Operating voltage Quiescent current Operating method Test facility Indoor variant rating Outdoor variant rating Temperature Humidity (non-condensing) Color Weight MA-CP Call point EN54 17V dc to 32V dc < 250µA Glass element with safety film Unique key IP42 IP65-10 C to +55 C 0 to 93% RH Red 0.2kg imensions: W H W H 87 (mm) 87 (mm) 36 (mm) Installation Highlights: Has a standard back box that can accept top or bottom surface entry cables. Can also be flush mounted. Provided with a special key for testing and cover removal (for maintenance), located at the bottom of the call point to facilitate ease of access. Separate loop in and loop out terminals for all connections including screen continuity. The fast fit self-locking clip on the front cover enables quick and simple installation (once in place, can only be removed by use of special key). Call point is triggered by pressing against the element. o not use high voltage testers if ANY equipment is connected to the system. Screen (Earth) must be continuous along entire length of loop. Order Codes: MA- CP Analog Call Point MA-CP / Addressable Loop evices: Interfaces 47

48 Conventional Fire Alarm Systems PROUCTS Conventional Fire Alarm Systems MB 200 Series / P.50 Conventional etectors MB-220 Photoelectric Conventional Smoke etector / P.52 MB-230 Conventional Heat etector (CMT360) / P.54 MB-240 Photo-Thermal Smoke etector / P.56 Sounders / Beacons MB-HO Symphony Electric Sounder / P.58 MB-Fl Flashni Sounder Beacon / P.60 Call Points MB-CPR Red Call Point / P.62 MB-CPY Yellow Call Point / P.62

49 MB Conventional Fire Alarm System The MB Conventional Range is a clever highly flexible, powerful and costeffective fire alarm control system capable of interfacing with leading fire detection systems currently available on the market. The MB Range is available as 2, 4 and 8 zone panels Class B with advanced programming capabilities, an operating voltage of 24Vdc, and a vast variety of functional features, making it an effective installer and end-user friendly fire detection solution.

50 MB 200 Series The MB 200-Series offers sophisticated features required of a leading-edge conventional fire alarm control panels, while meeting the demand for simple operation and installation requirements of both installers and building users. The MTech MB 200 conventional fire alarm control panels are available as 2, 4 and 8 Class B zone. It offers a vast variety of functional features that makes it a highly flexible, cost effective and powerful fire alarm control panel. The MB 200 Range conforms to and is capable of interfacing with leading conventional fire detection accessories and devices, by Cooper*, Apollo, Hochiki, System Sensor and others. The MB is compatible with conventional input devices such as smoke detectors, manual pull stations, water-flow devices, tamper switches and other normally-open contact devices. It can set off the audible and visual signaling devices of compatible smoke detectors or any normallyopen fire alarm initiating modules when activated. The MB comes standard with a 4.5 amp (also available in 6.5 amp), a 24Vdc smart power supply, and a vast variety of functional features with four Class B notification appliance circuits (NAC), three programmable relays, dedicated alarm and trouble relays, RS485 port and optional RS232 port. The NAC protocol is capable of programming outputs, and silence audible devices while strobes continue to flash using a single pair of wires. MTech also offers a remote annunciator panel expansion module, the MA-1050, designed to interface with the MB fire alarm control panel. *The MB also offers an integration capability, allowing it to work in cooperation with Cooper devices to enable cross-detector alarms in each of the zones. It also offers a cross zone between the zones for sophisticated functionality, and can provide Supervisory notification. The call-point can perform a cross-zone overwrite. Features: 2, 4 and 8 zone panels Class B (Style B) with supervised zone expanders and I/O modules that can be mounted remotely from the main control panel Event history buffer (up to 250 events) with a date/time stamp Six selectable/programmable output patterns for NACs Real time clock Maintenance trouble notification Cross detection alarm in the zone, MCP overwrite Four programmable NACs Three programmable relays One dedicated alarm relay One dedicated trouble relay RS485 ports, optional RS232 Work with remote annunciator Built-in walk test A viewing port in the keyed panel enclosure door to show the system status LEs and LC displays 24Vdc power supply, 4.5 amp (6.5 amp optional) 50 Conventional Fire Alarm Panel / MB-200 Series

51 MB 200 Series Panel Specifications: Model Standards Number of zones etectors per zone Panel sounder circuits Programmable relays (NAC/OPs) Alarm relay Trouble (fault) relay Mains input voltage System operating voltage battery Power supply Cable entries End of line resistor Environmental Rating Color Weight MB-202 MB-204 Approved to UL 864 9th Edition O/P NACs /230 V AC 24Vdc Up to Two 12V 12Ah 24Vdc, 4.5 amp (optional 6.5 amp) 4 Top Entry, 11 Right Side, 2 Left Side 4K 7 or EOLM 0ºC-49ºC, 95% RH (non condensing) Red 7 Kg MB imensions: MB-200 H W H 370 (mm) 393 (mm) 112 (mm) W Order Codes: MB-200 Range Conventional Fire Alarm System MB-200 Series / Conventional Fire Alarm Panel 51

52 MB-220 Photoelectric Conventional Smoke etector The MB-220 is an advanced photoelectric two-wire conventional smoke detector designed to operate with the MB-200 Series fire alarm system. Overview The MB-220 photoelectric smoke detector (opto) provides the fastest response to slow burning or smoldering fires that give rise to large visible smoke particles, and is suitable for most applications. The MB-220 is simple to install, all you need to do is plug it into the system, no hard addressing is needed. The detector operates on a low current, and is easy to maintain owing to its drift compensation and removable detector chamber for cleaning. Its advanced LE design offers 360 views. Features: rift compensation Maintenance trouble notification Low profile design LE design with 360 view Removable detector chamber Common mounting base Locking facility Benefits Fastest response to slow burning or smoldering fires Plug and play feature (with no hard addressing needed) Operates on low current Easy to maintain 52 Conventional etectors / MB-220

53 MB-220 Photoelectric Conventional Smoke etector Technical Specifications: escription Base Working voltage Voltage waveform Standby current (average) Surge current (maximum) Alarm current (maximum) Relay current (maximum) Start-up time Sensitivity Sensitivity checker Heat element rating Reset time (maximum) Heat detector spacing Ambient temperature (maximum) Mounting position Compatibility identifier MB-220 Photoelectric 2 wire MB VC Filtered C +/- 1 v max 120 Hz 95µA 340µA Must be limited externally to 40 ma N/A 20 seconds / % /ft Use no-climb TRUTEST UL Listing 77TL N/A 2 seconds N/A 32 F to 100 F Ceilings in open areas imensions: ia ia (excluding base) (including base) 101 (mm) 33 (mm) 45 (mm) Order Codes: MB-220 Photoelectric Conventional Smoke etector MB-220 / Conventional etectors 53

54 MB-230 Fixed Temperature Conventional Smoke etector The MB-230 is a fixed temperature conventional smoke detector designed to operate with the MB-200 Series fire alarm system. Overview The MB-230 fixed temperature sensor will detect a rapid increase in temperature or temperatures above 135 F or 194 F (dependent on switch selection). This sensor is designed to provide reliable fire detection especially in environments with high levels of dust, fumes, steam or smoke, conditions that may set-off false alarms. The detector operates on a low current, and is easy to maintain owing to its drift compensation and removable detector chamber for cleaning. Its advanced LE design offers 360 views. Features: rift compensation Maintenance trouble notification Low profile design LE design with 360 view Removable detector chamber Common mounting base Locking facility Benefits: etects a rapid increase in temperature or temperatures above 135 F or 194 F Operates on low current Easy to maintain 54 Conventional etectors / MB-230

55 MB-230 Fixed Temperature Conventional Smoke etector Technical Specifications: etector head Base Working voltage Voltage waveform Standby current (average) Surge current (maximum) Alarm current (maximum) Relay current (maximum) Start-up time Sensitivity Sensitivity checker Heat element rating Reset time (maximum) MB-230 ROR & Fixed Heat at 135 F MB VC Filtered C +/- 1 v max 120 Hz 70µA 340µA Must be limited externally to 40 ma N/A 20 seconds N/A Use No-Climb TRUTEST UL Listing 77TL 57 C or 135 F 2 seconds Heat detector spacing 50 ft Ambient temperature (maximum) F Mounting position Ceiling in open areas Compatibility identifier imensions: ia ia (excluding base) (including base) 101 (mm) 43 (mm) 55 (mm) Order Codes: MB-230 Fixed Temperature Conventional Smoke etector MB-230 / Conventional etectors 55

56 MB-240 Photo-Thermal Smoke etector The MB-240 is a photo-thermal conventional smoke detector designed to operate with the MB-200 Series fire alarm system. Overview The MB-240 photo-thermal smoke sensor uses combined photo and thermal signals to respond quickly to fast clean burning and smoldering fires. The sensor s thermal enhancement provides a higher alarm threshold and improves rejection of many common causes of nuisance alarm. The sensor will also raise an alarm at temperatures exceeding 135 F. The detector operates on a low current, and is easy to maintain owing to its drift compensation and removable detector chamber for cleaning. Its advanced LE design offers 360 views. Features: rift compensation Maintenance trouble notification Low profile design LE design with 360 view Removable detector chamber Common mounting base Locking facility Benefits: Combined photo and thermal signals for quick response Will raise an alarm at temperatures above 135 F Operates on low current Easy to maintain 56 Conventional etectors / MB-240

57 MB-240 Photo-Thermal Smoke etector Technical Specifications: escription Base Working voltage Voltage waveform Standby current (average) Surge current (maximum) Alarm current (maximum) Relay current (maximum) Start-up time Sensitivity Sensitivity checker Heat element rating Reset time (maximum) Heat detector spacing Ambient temperature (maximum) Mounting position Compatibility identifier MB-240 Photo-Thermal 2 wire MB VC Filtered C +/- 1 v max 120 Hz 95µA 340µA Must be limited externally to 40 ma N/A 20 seconds / % /ft Use no-climb TRUTEST UL Listing 77TL 135 F 2 seconds 50 ft 32 F to 100 F Ceilings in open areas imensions: ia ia (excluding base) (including base) 101 (mm) 43 (mm) 55 (mm) Order Codes: MB-240 Photo-Thermal Smoke etector MB-240 / Conventional etectors 57

58 MB-HO Electronic Sounder The MB-HO is a Symphony electronic sounder designed to operate with the MB-200 Series fire alarm system. Overview The MB-HO symphony electric sounder is an internal sounder, available either as a very high output sounder for noisy areas or high output low current sounder for applications where power is limited. The MB-HO can be set to three tones and has volume control functionality. It has a lockable base for easy installation. The MB-HO sounder is CP approved. A weatherproof version is also available. Features: CP Approval CP0141 & 0832CP tones Volume control Lockable base Weatherproof version available Benefits: Easy to install Low current High sound output 58 Conventional Fire Alarm Panel / MB- HO

EFBW series - BiWire Ultra control panel

EFBW series - BiWire Ultra control panel 4.2 Control panels and repeater panels EFBW series - BiWire Ultra control panel Eaton s new BiWire Ultra fire detection system is unlike any other standard conventional system as the panel, conventional

More information

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION Fike s CyberCat 254 (P/N 10-066) is a state-of-the-art true intelligent digital peer-to-peer modular fire alarm control system.

More information

Installation, Operating and Maintenance Manual

Installation, Operating and Maintenance Manual STATUS ZONES CONTROLS FIRE FAULT DISABLED FIRE 1 2 3 4 5 6 7 8 TEST FAULT DISABLED 1 5 BUZZER SILENCE RESET 1 2 TEST 2 6 LAMP TEST 3 SUPPLY 3 7 SYSTEM FAULT 4 8 SOUNDERS ACTIVATE/ SILENCE 4 FAULTS INSTRUCTIONS

More information

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION Fike s Cheetah Xi 50 (P/N 10-071) is a state-of-the-art true intelligent digital peer-to-peer modular suppression control system.

More information

Industries. As a premier global manufacturing company, we believe that great brands are

Industries. As a premier global manufacturing company, we believe that great brands are JSB Fire Systems ONE COOPER Every day, thousands of people all over the world use products made by Cooper Industries. As a premier global manufacturing company, we believe that great brands are built on

More information

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL PRODUCT Specification FEATURES Designed To Meet The Requirements Of EN54 Expandable From 1 To 5 Loops As Standard A Variety Of Networking Options

More information

CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM

CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION Fike s Cheetah Xi (P/N 10-068) is a state-of-the-art true intelligent digital peer-topeer modular suppression control system. It is ideal for

More information

Overview. Wireless Overview QLD NSW VIC Fundamentals. Operation. Features.

Overview. Wireless Overview QLD NSW VIC Fundamentals. Operation. Features. Wireless Overview www.incitefire.com.au Overview Fundamentals FIREwave is a wireless based family of products which is fully integrated into Hochiki s renowned ESP intelligent hardwired system. This seamless

More information

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel INSTALLATION, OPERATION AND MAINTENANCE MANUAL Version: CN-PM-1000.VER1.1-12/2012 EN54 INFORMATION In accordance with EN 54-2 clause 13.7, the maximum

More information

ACC-25/50ZST. Zoned System Voice with Telephone Evacuation Control Panel

ACC-25/50ZST. Zoned System Voice with Telephone Evacuation Control Panel ACC-25/50ZST Zoned System Voice with Telephone Evacuation Control Panel General The AUDIO COMMAND CENTER 25/50 Zone System with FireFighters Telephone (ACC-25/50ZST) is a state-of-the-art Emergency Voice

More information

GENERAL STANDARD FEATURES. ISO-9001 Engineering and Manufacturing Quality System Certified to International Standard ISO-9001 PATENT PENDING

GENERAL STANDARD FEATURES. ISO-9001 Engineering and Manufacturing Quality System Certified to International Standard ISO-9001 PATENT PENDING GENERAL The VEC 25/50 is a state-of-the-art, compact, stand-alone or slave Emergency Voice Evacuation Control. The VEC 25/50 is offered in a self-contained, cost-effective design and includes a 25 Watt,

More information

July 14, 1999 DF C-100.

July 14, 1999 DF C-100. www.firelite.com GENERAL The Fire Lite FIRE COMMAND 25/50 is a state-of-theart, compact, stand-alone or slave Emergency Voice Evacuation Control Panel (VECP). The FIRE COMMAND 25/50 is offered in a self-contained,

More information

System 800 Addressable Fire Detection & Alarm System

System 800 Addressable Fire Detection & Alarm System SECTION 5: page 1 Section 5: System 800 Addressable Fire Detection & Alarm System SECTION 5: page 3 10 reasons to specify 800 1 Plug and Play A user friendly panel not requiring special software tools

More information

Addressable Fire Alarm Control Panel

Addressable Fire Alarm Control Panel PRODUCT SPECIFICATION XR2400F Addressable FACP Addressable Fire Alarm Control Panel Description The DMP XR2400F Addressable Fire Alarm Control Panel is an expandable Fire Alarm Control with built-in DACT

More information

The supplier and installer of the system should be approved by the local civil defence authority.

The supplier and installer of the system should be approved by the local civil defence authority. ANALOGUE ADDRESSABLE FIRE ALARM SYSTEM 1. Scope of Work The contractor shall supply, install, test and commission a modern Analogue Addressable Fire Detection and Alarm System of an approved manufacturer

More information

Cooper Fire Systems. UL Listed Range

Cooper Fire Systems. UL Listed Range Cooper Fire Systems UL Listed Range UL Listed Fire Detection Equipment SIGNALING 4AC5 FIRE ALARM EQUIPMENT Underwriters Laboratories Inc. (UL) is an independent product safety certification organization,

More information

Solution F2. Fire Alarm Control Panels one step ahead.

Solution F2. Fire Alarm Control Panels one step ahead. Solution F2 Fire Alarm Control Panels one step ahead. Sicherheitstechnik Sicherheitstechnik GmbH GmbH The Fire Alarm Control Panel Solution F2 Solution F2 in B2 enclosure (B01090-00) The Concept The Solution

More information

C E R T I F I C AT LPCB I O N B O A R D P R E V E N T L O S S. Cooper Fire Systems

C E R T I F I C AT LPCB I O N B O A R D P R E V E N T L O S S. Cooper Fire Systems P R E V E N T L O S S I O N C E R T I F I C AT LPCB B O A R D I O N Cooper Fire Systems ONE COOPER Every day, thousands of people all over the world use products made by Cooper Industries. As a premier

More information

Addressable and Conventional Fire Protection

Addressable and Conventional Fire Protection Addressable and Conventional Fire Protection Simply reliable F I R E P R O T E C T I O N The MAGPro and Fireline systems has been created to balance performance, reliability and aesthetics whilst being

More information

Intelligent Single Loop Fire Alarm Control Panel

Intelligent Single Loop Fire Alarm Control Panel Intelligent Single Loop Fire Alarm Control Panel The CAX-CTL-1L Intelligent Single Loop Fire Alarm Control Panel is a member of the industry leading Axis AX Series Intelligent Fre Alarm Control Panels

More information

four Vigilon Compact Analogue Addressable Fire Detection & Alarm System 4/1

four Vigilon Compact Analogue Addressable Fire Detection & Alarm System 4/1 four Vigilon Compact Analogue Addressable Fire Detection & Alarm System 4/1 ANALOGUE FIRE DETECTION VIGILON COMPACT FEATURES & BENEFITS four Keep it Simple All Vigilon devices connect onto the same 2

More information

Data Sheet Fire Safety & Security Products. System Overview. Initiating Circuits SXL-EX FACP 7906

Data Sheet Fire Safety & Security Products. System Overview. Initiating Circuits SXL-EX FACP 7906 s Data Sheet Fire Safety & Security Products SXL-EX Fire Alarm Control Panel Conventional Zone Fire Alarm Control Panel ARCHITECT AND ENGINEER SPECIFICATIONS Four (4) zones expandable to eight (8) zones

More information

TECHNICAL DATA. multi-hazard. model vfr400. Release Control Panel 290a. January 16, 2014

TECHNICAL DATA. multi-hazard. model vfr400. Release Control Panel 290a. January 16, 2014 January 16, 2014 Release Control Panel 290a 1. Description The Viking VFR400 is a microprocessor based releasing control panel for use on preaction, deluge, Surefire, Firecycle multicycle sprinkler systems,

More information

Conventional Releasing Control Panel

Conventional Releasing Control Panel s Data Sheet Fire Safety Products Conventional Releasing Control Panel Pre-Action Deluge Agent-Releasing Fire System Model TXR-320 Remote configurable Up to two (2) hazard areas Operable with the following:

More information

The CWSI System CALL WITH QUESTIONS. RELY ON OUR KNOWLEDGE. DEPEND ON OUR EXPERIENCE. (800)

The CWSI System CALL WITH QUESTIONS. RELY ON OUR KNOWLEDGE. DEPEND ON OUR EXPERIENCE. (800) The CWSI System The CWSI wireless fire alarm product line offers system versatility like none other. Frequency Hopping Spread Spectrum Technology (FHSS), coupled with Bi-directional RF Communication, Repeater

More information

FireNET Plus Wiring Instructions

FireNET Plus Wiring Instructions FireNET Plus Wiring Instructions This manual provides wiring instructions for the 1 loop and 2 loop version of the FireNET Plus panels, which supports our finest Hochiki s DCP protocol. Note: Refer to

More information

Intelligent 2 & 4 Loop Fire Alarm Control Panels

Intelligent 2 & 4 Loop Fire Alarm Control Panels Intelligent 2 & 4 Loop Fire Alarm Control Panels Advanced has combined the latest technology with many years of fire experience, to create the Axis AX Series Intelligent Fire Alarm Control Panels. The

More information

SP40S-D. Kingfisher Company, inc. Features: Description:

SP40S-D. Kingfisher Company, inc. Features: Description: Kingfisher Company, inc. SP40S-D Features: Multi-use applications The system can function as an evacuation system, an emergency messaging system, and an employee notification system Fire code applications

More information

intelligent solutions

intelligent solutions Alco is one of the leading intelligent solution providers of Fire Detection System. Security System and Public Addressing System in the United States of America. Based in California since 1992, we have

More information

MODUL-R FIRE ALARM CONTROL PANELS. MR-2900/MR-2920 Addressable Fire Alarm Control Panels MEA. Features. Description

MODUL-R FIRE ALARM CONTROL PANELS. MR-2900/MR-2920 Addressable Fire Alarm Control Panels MEA. Features. Description MODUL-R FIRE ALARM CONTROL PANELS MR-2900/MR-2920 Addressable Fire Alarm Control Panels Description MR-2900 Fire Alarm Control Panel The MR-2900 fire alarm system control unit is the heart of a sophisticated

More information

Syncro AS. Analogue Addressable Fire Control Panel. User Manual

Syncro AS. Analogue Addressable Fire Control Panel. User Manual Syncro AS Analogue Addressable Fire Control Panel User Manual Man-1100 Issue 02 Nov. 2008 Index Section Page 1. Introduction...3 2. Safety...3 3. Panel Controls...4 3.1 Access Level 1...4 3.2 Access Level

More information

ED820-24V MODEL INSTRUCTION MANUAL. fire DETECTOR

ED820-24V MODEL INSTRUCTION MANUAL. fire DETECTOR ED820 24V MODEL fire DETECTOR INSTRUCTION MANUAL Address: Enigma House, Enigma Business Park, Malvern, Worcestershire, WR14 1GD Tel: 44 (0)1684 891500 Fax: 44 (0)1684 891600 Email: sales@electronicdevices.co.uk

More information

The EN54 Part 2 & 4 Fire System

The EN54 Part 2 & 4 Fire System Scope of work: To design, supply, install and commission an Analogue Addressable Fire Alarm Control System in accordance with the details specified herein and in accordance with supplied drawings The EN54

More information

TrueAlarm ES Analog Sensing

TrueAlarm ES Analog Sensing TrueAlarm ES Analog Sensing UL, ULC, CSFM Listed; FM Approved* Features TrueAlarm addressable sensor base with 520 Hz sounder TrueAlarm sensor bases with 520 Hz tone require a TrueAlarm photoelectric,

More information

ACP10 & ACP50 Security Systems

ACP10 & ACP50 Security Systems ACP10 & ACP50 Security Systems System Configuration LCD Keypad LCD Keypad LED Keypad LED Keypad 4-wire Bus ACP10 & ACP50 AEX10* AEX10* AEX10* AEX10* * ACP50 Only Control Panels The ACP10 control panel

More information

Specification/ Data Sheet

Specification/ Data Sheet Specification/ Data Sheet TRITON RP Agent Release Control Panel FEATURES Agent Release Control Panel designed specifically for suppression release operation with: Four initiating device circuits (IDCs)

More information

ECC-50/100C. Emergency Command Center

ECC-50/100C. Emergency Command Center ECC-50/100C Emergency Command Center Canadian DF-60815:B Emergency Communications General Fire-lite s ECC-50/100C is a multipurpose emergency voice evacuation panel for fire applications, mass notification

More information

Conventional systems Product Name

Conventional systems Product Name Product Name 56 EATON - FIRE AN VOICE ALARM SYSTEMS CF-CC2556 January 2015 Contents Contents Conventional fire systems Panels FXP4000 series panel 58 FXP5000 series panel 60 evices etectors and indicators

More information

Control Relay Modules

Control Relay Modules TM INTERNATIONAL ANALOG ADDRESSABLE INPUT/OUTPUT DEVICES Control Relay Modules Model SIGA-CR, SIGA-MCR, SIGA-CRR, Features! Provides one no/nc contact (SIGA-CR/MCR) Form C dry relay contact can be used

More information

Analogue addressable devices

Analogue addressable devices Apollo XP95 Analogue addressable devices from Channel Safety Systems Apollo XP95 Analogue addressable devices The XP95 range of analogue addressable fire detectors is advanced in design, improved in performance

More information

ELECTRONIC SOUNDER STROBE Model : AVD-C407

ELECTRONIC SOUNDER STROBE Model : AVD-C407 ELECTRONIC SOUNDER STROBE Model : AVD-C407 MULTRON range of combination Electronic Sounders with Strobe Lights are designed to complement our Fire Alarm products both technically and aesthetically as an

More information

Emergi-Lite Orbis detectors

Emergi-Lite Orbis detectors Emergi-Lite Orbis detectors Emergi-Lite Orbis brings the latest in fire detector microprocessor technology to the Firetec and Eurofire systems. Non-addressable (conventional) smoke and heat sensors respond

More information

An introduction to... Sigma

An introduction to... Sigma An introduction to... Sigma XT+ Sigma XT+ Overview The Sigma XT+ 21000 series are the latest additions to the Sigma family of control equipment from Kentec Electronics Limited. The Sigma XT+ range combines

More information

MINERVA. Marine. Fire Detection. MX T2000 Panel Range. Features: MINERVA Marine Panel Range

MINERVA. Marine. Fire Detection. MX T2000 Panel Range. Features: MINERVA Marine Panel Range Fire Detection MINERVA Marine MX T2000 Panel Range Features: Enhances fire detection and eliminates unwanted alarms using fuzzy logic Assists fire fighting and training by providing on-screen risk management

More information

End To End Optical Beam Smoke Detector. Additional Information

End To End Optical Beam Smoke Detector. Additional Information End To End Optical Beam Smoke Detector Additional Information EN 1. Multiple Zone Wiring When using more than one System Controller on a single zone of a conventional Fire Control Panel (FCP), it is important

More information

Intelligent addressable fire alarm control panel

Intelligent addressable fire alarm control panel Intelligent addressable fire alarm control panel Input current consumption: Panel rating: Batteries: Networking and Interfaces Panel to panel communication: Number of panels: Interface port: System capacity

More information

ECC-50/100(E) Emergency Command Center. General. Features. Emergency Voice Evacuation TYPICAL APPLICATIONS

ECC-50/100(E) Emergency Command Center. General. Features. Emergency Voice Evacuation TYPICAL APPLICATIONS ECC-50/100(E) Emergency Command Center DF-60734:A4 General Firelite s ECC-50/100 and ECC-50/100E are multipurpose emergency voice evacuation panels for fire applications, mass notification applications,

More information

(68.52) X. June 2000 supersedes February vigilon ADVANCED FIRE DETECTION & ALARM SYSTEMS

(68.52) X. June 2000 supersedes February vigilon ADVANCED FIRE DETECTION & ALARM SYSTEMS (68.52) X June 2000 supersedes February 2000 vigilon ADVANCED FIRE DETECTION & ALARM SYSTEMS VIGILON SYSTEM ARCHITECTURE Repeat Panel Spur Manual Call Point T-breaker Alarm Sounder Max loop length 1000m

More information

ZIOU/230 - MAINS IO INSTRUCTION MANUAL

ZIOU/230 - MAINS IO INSTRUCTION MANUAL Description ZIOU/230 - MAINS IO INSTRUCTION MANUAL The Mains IO Modules are fully monitored loop powered devices which permit the interfacing of third party equipment with the Fire Alarm Control panel

More information

ADR Analog Addressable Fire Alarm Control Panel. Technical Manual. Control Panels. 3000En. En pdf

ADR Analog Addressable Fire Alarm Control Panel. Technical Manual. Control Panels. 3000En. En pdf Control Panels Analog Addressable Fire Alarm Control Panel Technical Manual TELEFIRE FIRE & GAS DETECTORS LTD PO Box 7036 Petach Tikva 49250 Israel Tel: 972 3 970 0400 Fax: 972 3 921 1816 email: Web: info@telefire.co.il

More information

4 wire conventional alarm system

4 wire conventional alarm system Scimitar 4 wire conventional alarm system from Channel Safety Systems Scimitar 4 wire conventional alarm system The Scimitar Fire Alarm Control System is a comprehensive range of high specification conventional

More information

30.45 Electric Release PDRP-2001

30.45 Electric Release PDRP-2001 The PDRP-2001 Fire Alarm Control Panel (FACP) is a six-zone control panel for single and dual hazard deluge and preaction applications. The FACP is compatible with conventional input devices (2-wire or

More information

LF /2. Fire Alarm Control Panel. Features:

LF /2. Fire Alarm Control Panel. Features: LF-6100 1/2 Fire Alarm Control Panel Features: Microprocessor Based System Intelligent Distributed System Structure Quick Response Time Fire Alarm in less than 1 Second Capacity of 200/500 Addressable

More information

MPC-6000 / MPC-7000 / RND-2

MPC-6000 / MPC-7000 / RND-2 MPC-6000 / MPC-7000 / RND-2 Fire Alarm System Control Unit Installation, Operation and Maintenance Manual Siemens Building Technologies, Inc. 8 Fernwood Road Florham Park, NJ 07932 Tel: (973) 593-2600

More information

Sita200plus. 200detectors. Single loop analogue addressable System

Sita200plus. 200detectors. Single loop analogue addressable System Single loop analogue addressable System Fast short circuit isolator in every device 15 combinations of smoke & heat detection modes Loop length up to 2km long with spurs INTELLIGENT FIRE TECHNOLOGY A D

More information

HART XL High Sensitivity Smoke Detection

HART XL High Sensitivity Smoke Detection High Sensitivity Smoke Detection The Hart XL High Sensitivity Smoke Detection system (HSSD) is an aspirating fire detection system designed to give very early indication of an incipient fire condition.

More information

LifeAlarm Fire Alarm Controls

LifeAlarm Fire Alarm Controls UL, ULC Approved* LifeAlarm Fire Alarm Controls 4009 IDNet NAC Extender for Control with IDNet Communications or Conventional NACs Features Provides additional notification appliance circuit (NAC) capacity

More information

Touch Screen 1 loop Addressable Fire Alarm Panel

Touch Screen 1 loop Addressable Fire Alarm Panel evolution 1 Touch Screen 1 loop Addressable Fire Alarm Panel The evolution 1 control panel offers complete compatibility with the award winning range of Nittan evolution detection and alarm devices and

More information

good things in small packages

good things in small packages FireShield Control Panels good things in small packages life safety for small buildings and shops A perfect arrangement FireShield offers the very best conventional fire alarm technology available, with

More information

R A D I O N I C S. READYKEY K2015A Alarm Event Manager. Installation Data Sheet. Description

R A D I O N I C S. READYKEY K2015A Alarm Event Manager. Installation Data Sheet. Description R A D I O N I C S READYKEY K2015A Alarm Event Manager Installation Data Sheet READER CONTROLLER INPUTS INPUTS RLY 8 RLY 7 RLY 6 RLY 5 RLY 4 RLY 3 RLY 2 RLY 1 8 Supervised Inputs (Normally Open or Normally

More information

Conventional Fire Alarm System 2014 V1.2

Conventional Fire Alarm System 2014 V1.2 Conventional Fire Alarm System 2014 V1.2 Product Overview Control Panel 2 Conventional Fire Panel GST102A 2 zone Fire panel GST104A 4 zone Fire panel GST108A 8 zone Fire panel GST116A 16 zone Fire Panel

More information

Xenex Conventional Fire Detection & Alarm System

Xenex Conventional Fire Detection & Alarm System SECTI 4: page 1 Section 4: Xenex Conventional Fire Detection & Alarm System SECTI 4: page 3 Xenex system architecture Beam Transmitter Beam Receiver End of Line Call Point Smoke Detector Smoke Detector

More information

Interface Modules for SENTRI

Interface Modules for SENTRI EQUIPMENT INTERFACED Data and Installation Interface s for SENTRI Low voltage (LV) / SEN-INT-INPUT 1- Interface (low voltage) SEN-INT-OUTPUT 1- & 1- Interface (low voltage) SEN-INT-4IO # 4- / Interface

More information

For Complete Fire and Gas Solutions

For Complete Fire and Gas Solutions Industrial Fire For Complete Fire and Gas Solutions 2 The Total Package What do you need from an integrated fire and gas system? In industrial fire and gas environments it s important to have a reliable

More information

The ID51 & ID52 can be upgraded to 2 loops without the need to change back box. FEATURES. Intelligent Features

The ID51 & ID52 can be upgraded to 2 loops without the need to change back box. FEATURES. Intelligent Features 990-052, Issue 6 20 March 2006 ID50 Series Single Loop Intelligent Fire Alarm Panels Section: Intelligent Fire Alarm Panels GENERAL The NOTIFIER ID50 series single loop intelligent fire alarm panels, has

More information

Eaton is a global leader with expertise in:

Eaton is a global leader with expertise in: JSB Fire Systems P o w e ring business worldwide As a global l diversified power management company, we help customers worldwide manage the power n e e d e dfor buildings, aircraft, trucks, cars, machinery

More information

D8024, D9024, D10024 Analog Fire Alarm Control Panels Programming Guide

D8024, D9024, D10024 Analog Fire Alarm Control Panels Programming Guide System Reset Trou ble Silence Ala rm Silence Manual Ala rm ENTER NO YES Letters Numb ers Keyword Radionics System Reset Trouble Silence Alarm Silence Manual Alarm ENTER NO YES Le ters Numbers Keyw ord

More information

MINERVA MZX125 Digital Addressable Fire Detection System

MINERVA MZX125 Digital Addressable Fire Detection System DATASHEET MINERVA MZX125 Digital Addressable Fire Detection System The Minerva MZX125 is a highly featured digital addressable panel with a comprehensive but easy to operate user interface. The system

More information

Conventional Smoke Detectors KFAPO

Conventional Smoke Detectors KFAPO Kingfisher Company, inc. Conventional Smoke Detectors KFAPO Features: Wide operating voltage, 9-33 VDC Advanced electronic technology Flashing LED Magnetic test switch Proven detection performance Designed

More information

Commercial and Light Industrial Fire Alarm Control Panel

Commercial and Light Industrial Fire Alarm Control Panel FireSystem 2000 Commercial and Light Industrial Fire Alarm Control Panel Features Easily expandable. All new plug-in board design Two supervised audible circuits Lamp and system trouble circuit test Ground

More information

LifeAlarm Fire Alarm Control Panels

LifeAlarm Fire Alarm Control Panels LifeAlarm Fire Alarm Control Panels UL, ULC Approved* Features Control panel operator convenience features: Wide viewing angle 2 x 20 (40 character) alphanumeric LCD and dedicated LEDs provide convenient

More information

The complete conventional fire warning system

The complete conventional fire warning system The complete conventional fire warning system www.espuk.com MAG2P 2 Zone Fire Panel 2 programmable zones Active end of line monitoring and head removal 30 fire detectors per zone Unlimited number of call

More information

Evolution Analogue Addressable Fire System

Evolution Analogue Addressable Fire System Addressable Fire System optimum fire safety systems solutions High speed FSK protocol, uniquely resistant to noise Up to 254 addresses per loop for flexible system design Built to exceptional marine standards

More information

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices. FireCell Radio Hub Fully addressable Wireless activation Third party approved (EN54) 2-way radio communication Loop powered Diagnostics port Range in excess of 150 metres Overview The model FCX-500-001

More information

Installation Guide for AL800UL-ADA. NAC Power Extender. Rev

Installation Guide for AL800UL-ADA. NAC Power Extender. Rev Installation Guide for AL800UL-ADA NAC Power Extender Rev. 090500 Overview: The Altronix AL800UL-ADA is an extremely cost effective 8 amps voltage regulated remote power supply /battery charger. The AL800UL-ADA

More information

Conventional Fire Detection

Conventional Fire Detection SECTI 4: page 1 Section 4: Conventional Fire Detection Contents System Architecture Control Panel Automatic & Manual Detection Manual Call Points Smoke Detectors Heat Detectors Beam Smoke Detectors Duct

More information

ZXSe Range Data Sheet

ZXSe Range Data Sheet ZXSe Range Data Sheet Analogue addressable fire alarm control panel Product Overview The ZXSe range of analogue addressable fire alarm control panels have been designed and constructed around proven and

More information

Vega Devices.

Vega Devices. Vega Devices This document lists the Argus Vega devices that are compatible with the Panels. It also highlights any specific requirements and technical information. Range of Fire Alarm Control The operation

More information

PEGAsys. Multi-Loop Intelligent Suppression Control System FEATURES DESCRIPTION. Effective: March 2007 K

PEGAsys. Multi-Loop Intelligent Suppression Control System FEATURES DESCRIPTION. Effective: March 2007 K PEGAsys Multi-Loop Intelligent Suppression Control System A UTC Fire & Security Company Effective: March 2007 K-76-028 FEATURES UL Listed CSFM Approved MEA Approved Peer-to-Peer Networking (to 32 nodes)

More information

Protec. Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System. Fire Detection - Addressable

Protec. Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System. Fire Detection - Addressable Protec Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System ADDRESSING SAFETY SYSTEMS WITH INTELLIGENCE Protec Protec Algo-TecTM 6100 INTERACTIVE DIGITAL ADDRESSABLE FIRE CONTROL

More information

Addressable Detectors & Bases

Addressable Detectors & Bases Edwards Signaling Catalog u Intelligent Initiating Addressable Detectors & Bases Detectors: E-PD, E-PHD, E-HD Bases: B4U, RB4U, IB4U, SB4U Overview Edwards intelligent addressable detectors are meticulously

More information

Intelligent Detection Devices

Intelligent Detection Devices Intelligent Detection Devices Multi-Criteria Fire Detector [with ASAtechnology TM ] Advanced multi-criteria fire detector that has dual-optical and thermal sensors Differentiates between deceptive phenomena

More information

Fire-Cryer. Plus Application Guide APPLICATION GUIDE FIRE EXIT VIMPEX. Shaping Alarm Technology

Fire-Cryer. Plus Application Guide APPLICATION GUIDE FIRE EXIT VIMPEX. Shaping Alarm Technology Fire-Cryer Plus Application Guide APPLICATION GUIDE FIRE EXIT VIMPEX Shaping Alarm Technology Fire-Cryer Plus The Fire-Cryer range of voice sounders was first introduced to the market by Vimpex in 1999.

More information

AL800ULADA. NAC Power Extender. Installation Guide

AL800ULADA. NAC Power Extender. Installation Guide AL800ULADA NAC Power Extender Installation Guide Rev. 122000 AL800ULADA - NAC Power Extender Overview: The Altronix AL800ULADA is an extremely cost effective 8 amp voltage regulated remote power supply/battery

More information

SYSTEM MANUAL FT1-SB. Single Zone Fire Alarm System

SYSTEM MANUAL FT1-SB. Single Zone Fire Alarm System SYSTEM MANUAL FT1-SB Single Zone Fire Alarm System DOCUMENT HISTORY Issue Date Description Written By Checked By Draft 0 2/9/2008 Original Document. A. Shenouda C. Orr Issue 1 4/11/2011 Update drawing

More information

TECHNICAL DATA OBSOLETE

TECHNICAL DATA OBSOLETE Deluge Devices 270a 1. PRODUCT NAME VIKING PAR-3 Available since 1991 2. MANUFACTURED FOR: THE VIKING CORPORATION 210 N. Industrial Park Road Hastings, Michigan 49058 U.S.A. Telephone: (269) 945-9501 (877)

More information

CerberusTM. PRO intelligent protection. A comprehensive fire protection system. Answers for infrastructure.

CerberusTM. PRO intelligent protection. A comprehensive fire protection system. Answers for infrastructure. CerberusTM PRO intelligent protection A comprehensive fire protection system Answers for infrastructure. Cerberus PRO intelligent protection Fire safety is all about protecting people and assets and securing

More information

MINERVA MX. 800 Series Ancillary Equipment

MINERVA MX. 800 Series Ancillary Equipment An extensive range of ancillary modules has been specifically designed for use with the MX range of Fire Controllers. The 800 range of ancillary modules provide the MX Fire Controller with a wide degree

More information

AL600ULADA. NAC Power Extender. Installation Guide

AL600ULADA. NAC Power Extender. Installation Guide AL600ULADA NAC Power Extender Installation Guide Rev. 122000 AL600ULADA - NAC Power Extender Overview: The Altronix AL600ULADA is an extremely cost effective 6.5 amp voltage regulated remote power supply/battery

More information

Syncro Matrix Analogue Addressable Fire Alarm Mimic Panel Product Manual

Syncro Matrix Analogue Addressable Fire Alarm Mimic Panel Product Manual Syncro Matrix Analogue Addressable Fire Alarm Mimic Panel Product Manual Australia Issue 01 April 2012 Contents 1 Introduction 3 2 Safety 3 3 Installation 4 3.1 Mounting the Cabinet 4 4 Specifications

More information

This wiring diagram describes circuit connections for all models of the Series Quaestor-SZU Releasing Fire Control

This wiring diagram describes circuit connections for all models of the Series Quaestor-SZU Releasing Fire Control File: S8485 Wiring Diagram This wiring diagram describes circuit connections for all models of the Series Quaestor-SZU Releasing Fire Control Panel. The operation of this product is intended for indoor

More information

Fire detection and alarm

Fire detection and alarm Fire detection and alarm Aesthetic Install all cabling and cable containment neatly and unobtrusively, meeting the highest electrical industry installation standards. Neatly lay and securely fix cables.

More information

June 10, 2002 DF C S2424

June 10, 2002 DF C S2424 GENERAL www.firelite.com The Fire Lite FIRE COMMAND 25/50X is a state-of-theart Emergency Voice Evacuation Control Panel (VECP), with significant technological enhancements that set it apart from other

More information

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev AL802ULADA NAC Power Extender Installation Guide (See Application Guide for additional information) Rev. 031703 Overview: The Altronix AL802ULADA is an extremely cost effective 8 amp voltage regulated

More information

DCS-100. intelligent damper control & monitoring system

DCS-100. intelligent damper control & monitoring system DCS-100 intelligent damper control & monitoring system 02 //DCS-100 Introduction The Disys Technologies DCS-100 is a revolutionary new control system designed specifically for the fire/smoke damper controls

More information

INPUT / OUTPUT MINI MODULES

INPUT / OUTPUT MINI MODULES INPUT / OUTPUT MINI MODULES APPLICATION The Addressable Control and Monitor mini modules are the latest technology for a loop powered module. Installed on the same loop with other devices such as detectors

More information

FTEN1, FTEN2, & FTEN4 1, 2 & 4 ZONE FIRE DETECTION AND ALARM CONTROL PANELS

FTEN1, FTEN2, & FTEN4 1, 2 & 4 ZONE FIRE DETECTION AND ALARM CONTROL PANELS QUICK USER GUIDE FOR, 2 & 4 ZONE PANELS INDICATORS COLOUR INDICATION MON FAULT Yellow On when a fault condition has occurred, or if no other fault Led is on, this indicates 24v auxiliary fuse failure.

More information

Protec. Protec Algo-Tec TM 6500 Interactive Digital Addressable Fire Control System with Algo-Tec 6600 Bridging Network. Fire Detection - Addressable

Protec. Protec Algo-Tec TM 6500 Interactive Digital Addressable Fire Control System with Algo-Tec 6600 Bridging Network. Fire Detection - Addressable Protec Protec Fire Detection Pty Ltd Protec Algo-Tec TM 6500 Interactive Digital Addressable Fire Control System with Algo-Tec 6600 Bridging Network ADDRESSING SAFETY SYSTEMS WITH INTELLIGENCE CAUTION

More information

Multi-Point Peripherals

Multi-Point Peripherals UL, ULC Approved* Multi-Point Peripherals TrueAlarm CO Sensor Bases for Smoke, Heat, and Photo/Heat Sensors using IDNet Communications Features Fig 1: TrueAlarm CO Sensor Base with Sounder (shown with

More information

HART XL High Sensitivity Smoke Detection

HART XL High Sensitivity Smoke Detection High Sensitivity Smoke Detection Hart XL High Sensitivity Smoke Detection (HSSD) TM is a smoke detection system that is simple to install, commission, service and use yet remains brilliantly capable in

More information