Differential Pressure and Flow Meter Media 5 Indicator 160 PN 40

Size: px
Start display at page:

Download "Differential Pressure and Flow Meter Media 5 Indicator 160 PN 40"

Transcription

1 Differential Pressure and Flow Meter Media 5 Indicator 160 PN 40 Application Instrument designed to measure and indicate differential pressure or measured variables derived from it For gases or liquids Differential pressure ranges from mbar Static pressures up to 40 bar Optionally with limit switch with two inductive alarm contacts. Optional measurements: Liquid level in pressure tanks, especially for cryogenic, liquefied gases Differential pressure between flow and return pipe Pressure drop across valves and filters Flow rate acc. to the differential pressure method Special features Suitable for liquids, gases and steam Limit switch can be easily retrofitted Overloadable on one side up to the perm. static pressure Suitable for field (degree of protection IP 54) and panel mounting Zero adjustment on the front Adjustment of measuring span 1:2 Housing of indicating unit with burst protection Directly connectable valve block (flange mounting) with test connection to check the pressure in the tank Connection for pressure switch Fig. 1 Media 5, Indicator 160 with attached valve block and operating pressure gauge Versions (Figs. 1 and 2) Media 5 consisting of: Indicator NG 160 with pointer mechanism Differential pressure cell (brass) PN 40 1) Version free of oil and grease for oxygen Measuring ranges from mbar ECO measuring diaphragm Zero adjustment on the front Process medium connection G 3/8 A Optionally equippable with: Scales Scale from 100% linear or squared; Scale according to DIN 19204; Detachable scales for different media; Special scales Inductive limit switch with up to three alarm contacts A1/A2/A3 (proximity switches) Version for hazardous locations Valve block directly flange mounted onto Media 5 devices Pressure gauge Screw joints Special versions available on request 1 2 Fig. 2 Media 5, Indicator 160 with limit switches and attached valve block with operating pressure gauge 1 Zero adjustment 2 Alarm contacts A1/A2 3 Valve block with pressure gauge and shut-off valves 4 Screw joints 3 4 1) Nominal pressure PN 50 available on request Associated Information Sheet T 9500 EN Edition September 1999 Data Sheet T 9519 EN

2 Principle of operation (Fig. 3) The differential pressure cell operates according to the deflection method and contains a ECO measuring diaphragm (1.5) which is designed to handle measuring spans from mbar. The diaphragm rod (1.7) is connected to a lever (1.8) and is supported and guided by the measuring springs. The lever leads the deflection of the measuring system out of the pressure chamber. The pressure chamber is sealed by means of a flexible disk (1.9). The measuring springs, which are connected to the housing, and the diaphragm ensure that the position of the lever is independent of the static pressure. The differential pressure cell can be overloaded from one side, because the measuring diaphragm flexes against the housing wall whenever the measured values are out of range. The differential pressure p = p 1 p 2 produces a force on the diaphragm (1.5) which is balanced by the measuring springs (1.4). The deflection of the measuring diaphragm and the lever (1.8) is proportional to the differential pressure measured and is converted to pointer (2.4) position with the adjustable transmission element (2.1) and the pointer mechanism (2.2) having jewelled bearings. The measuring springs (1.4) installed in the differential pressure cell determine the lower and upper limit of the respective measuring span (measuring range limit) of the device (see Table 2 "Technical data"). The span can be continuously adjusted within these limits of application according to the ratio 1:2 at the transmission element. This adjustment changes the transmission ratio between the lever (1.8) and the pointer mechanism (2.2). The measuring unit shaft (3.1) carries the metal tags (3.2) and moves them according to the operating direction into the limit switch unit with the two alarm contacts (proximity switches) A1 and A2 (3.3). If a metal tag enters the inductive field of the associated proximity switch, the switch becomes highly resistive (contact open). If the tag leaves the inductive field, the proximity switch becomes low resistive (contact closed). This function corresponds to that of a mechanical-type switching contact. The proximity switches are adjustable independent of one another and according to any user requirement. They provide a signal when the differential pressure either increases or decreases and the metal tags enter or leave the inductive field of the switch. The proximity switches have a LED indicator, allowing the limit values to be adjusted on site without any problems. Switching amplifiers (transistor relays) must be connected in the output circuit of the inductive alarm contacts A1/A2 in such a way that they meet the operational requirements of any connected control and signalling devices A1 p 2 ( ) (+) p 1 p 2 p 1 Fig. 3 Functional diagram of the indicator with 2 alarm contacts 1 Differential pressure cell 1.1 Housing of dp-cell 1.2 High pressure chamber 1.3 Low pressure chamber 1.4 Measuring springs (6 per measuring range) 1.5 Measuring diaphragm 1.6 Diaphragm plates 1.7 Diaphragm rod 1.8 Lever 1.9 Flexible disk A Indicating unit 2.1 Transmission element 2.2 Pointer mechanism 2.3 Scale 2.4 Pointer 3 Limit switch 3.1 Measuring unit shaft 3.2 Metal tags 3.3 Alarm contacts A1/A2 4 Valve block 4.1 Valve block with pressure gauge, shut-off valves, screw joints and test connection 2 T 9519 EN

3 Limit switch (alarm contacts A1, A2, A3) Proximity switches (NC, normally closed) Metal tag outside inductive field Switching signal "ON" (L-signal of the proximity switch) - Function: contact closed or output activated - Low resistive (undamped), power consumption 3 ma Adjustment range 1.1 Alarm contact A1 Adjustment range Adj. range 2.1 Alarm contact A3 Adj. range 2.2 Alarm contact A2 Metal tag inside inductive field Switching signal "OFF" (0-signal of the proximity switch) - Function: contact open or output disabled - Highly resistive (damped), power consumption 1 ma A1 = 1st min. contact A2 = 2nd min. contact A3 = max. contact Fig. 4 Limit switch with 3 alarm contacts in the indicating unit Table 1 Functions of the alarm contacts A1 and A2 Overview of functions Proximity switch for... Tapping of gas (min. contact) Adjustment ranges Filling of tank (max. contact) Alarm contacts A1 A2 A1 A2 Metal tag inside field Metal tag outside field Limit switch with 2 alarm contacts - Terminal assignment - LED1 LED Table 2 Functions of the alarm contacts A1, A2, A3 Overview of functions Proximity switch for... Adjustment ranges Tapping of gas (2 min. contacts) Filling of tank (1 max. contact) Alarm contacts A1 A2 A3 Activation when metal tag inside field Switching points Min. contacts when indication decreases Max. contacts when indication increases + + A1 A2 Fig. 5 Terminal assignment of A1 and A2 Limit switch with 3 alarm contacts - Terminal assignment - LED1 LED2 LED3 Table 3 Technical data for limit switch in type of protection EEx ia IIc T6 Maximum values for connection to certified intrinsically safe circuits U 0 16 V I K 52 ma P 169 mw Max. values at terminals 41/42; 45/46; 51/52 Effective internal inductance L i 250 µh Effective internal capacitance C i 50 nf Temperature class T6 T5 T4 Perm. ambient temperature 60 C 75 C 80 C A1 A2 A3 Fig. 6 Terminal assignment of A1, A2, A3 3 T 9519 EN

4 Table 2 Technical data All pressures in bar or mbar (gauge) Differential pressure meter Measuring range mbar ) Measuring span min to max Nominal pressure PN 40 1), overloadable on one side up to 40 bar Indicator 160 Performance Indicator linear to differential pressure Terminal-based non-conformity < ± 2.5 % < æ1.6 % (including hysteresis) Sensitivity < 0.5 % < 0.25 % Effect of static pressure < 0.03 % / 1 bar Limit switch unit Max. 3 alarm contacts A1/A2/A3 with proximity switches and LC display (acc. to Namur and DIN 19234) Control circuit Rating according to the connected transistor relay 2) Proximity switch 3) Type SJ 3.5N-LED 4) Switching accuracy < ±2 % Range of inversion, approx. < 0.6% Perm. ambient temperature range for oxygen C C Perm. storage temperature range C Degree of protection acc. to DIN IP 54 Weight Without valve block With valve block Approx. 3.0 kg Approx. 5.0 kg 1) Oxygen version for nominal pressure of up to PN 50 available on request. 2) For example WE77/Ex 2 or from the K system KFA6-SR2-Ex2.W. 3) Proximity switches can be used in hazardous areas, corresponding to the Certificate of Conformity PTB No. Ex-95.D.2195X. 4) Other limit switches available on request. Note: All errors and deviations are given in % of the adjusted measuring span. For flow measurement, see Data Sheet T 9550 EN. The technical data related to the special version are the same as for the standard version. Table 3 Materials (WN = Material Number according to DIN) Version Standard version Special version Housing of differential pressure cell Cu Zn 40 Pb CrNi-steel Measuring diaphragm and seals ECO Measuring springs Diaphragm plates and function parts CrNi-steel Lever Housing of indicating unit Polycarbonate 4 T 9519 EN

5 Installation (see Fig. 6) Tube mounting - With mounting device and clamp for attaching to a vertical or horizontal 2" tube. Wall/panel mounting Through two M 8 tapped holes located in the valve block or on the rear cover of the dp-cell. Panel mounting With either cheese head screws M 4 and thread M 4 in the panel or hexagon head screws with M 4 nuts (see Fig. 7/panel mounting). Process medium connection: Tapped hole ISO 228 G 3 8. Installation and dimensions in mm Tube mounting Mounting device Vertical tube Horizontal tube Clamp Press. gauge NG 100, AB-Wesel Dimensions in mm Safety version a b S1 EN S3 EN SW17 b a Wall mounting Panel mounting Panel cut-out Ø ,2-0,3 Center line of the indicating unit Holes 8.5 for fastening screws M 8 Ø Cut-out 52 Six tapped holes M 4 or holes with 4.5, for hexagon head screws with nuts M 4 Option of using either 3 x 120 or 4 x 90. Fig. 7 Dimensions 5 T 9519 EN

6 Ordering text Differential Pressure Meter/Flow Meter Media 5 Nomenclature for ordering: - Complete the order number according to the instrument version chosen - Instrument version Order No A - Media 5, dp cell CuZn40Pb2 0 Media 5, dp cell WN ) 1 Standard version 0 Version free of oil and grease for oxygen 2) acc. to standard , Page 1 1 Measuring range Measuring span Min. Max mbar 40 mbar 60 mbar mbar 50 mbar 100 mbar mbar 80 mbar 160 mbar mbar 125 mbar 250 mbar mbar 200 mbar 400 mbar mbar 300 mbar 600 mbar mbar 500 mbar 1000 mbar mbar 800 mbar 1600 mbar mbar 1250 mbar 2500 mbar mbar 2000 mbar 3600 mbar 2 3 Zero adjustment screw with zero point correcting screw (standard version) 0 with covered zero point correcting screw 1 Limit switch unit 3) without limit contacts 0 with 2 inductive limit contacts, Type SJ 3.5N-LED with 3 inductive limit contacts, Type SJ 3.5N-LED 2 3 Additionally required order specifications Measured value adjustment 4) Unit adjusted to:... mbar Additionally required order specifications Alarm contacts Contact A1 Contact A2 Contact A3 Min. contacts = measured value decreases Metal tag is inside outside inside outside inside outside Max. contacts = measured value increases For measured value 1) Special version available on request. 2) Version for oxygen up to nominal pressure PN 50 on request. 3) For limit switch unit from factory. Standard: without adjustment. 4) For measured value adjustment from factory. Standard: 0... max. measured value. For switching value...mbar... mbar... mbar Scale version required (see T 9545 EN), Accessories: valve block, pressure gauge, screw joints (see T 9555 EN) Specifications subject to change without notice. 1fNORMAL.STY@ADRESSE = SAMSON AG MESS- UND REGELTECHNIKWeismüllerstraße 3 D Frankfurt am MainTelefon (0 69) T 9519 EN

Differential Pressure and Flow Meter. Media 5 Indicator 160 Ø PN 50

Differential Pressure and Flow Meter. Media 5 Indicator 160 Ø PN 50 Differential Pressure and Flow Meter Media 5 Indicator 160 Ø PN 50 Application Transmitter for measuring and indicating the differential pressure or measured variables derived from it Suitable for gases

More information

Rotameter series 250 metal tube variable area flowmeter

Rotameter series 250 metal tube variable area flowmeter Technical data Sheet Flow meter Rotameter series 250 metal tube variable area flowmeter MODELES 250 Stainless Steel indicator 250 PTFE 250 indicator + Alarm 250 electronic transmitter 4-20mA 250 electronic

More information

DP-500. Target Flowmeter. Flow measurement of Gases and Liquids. Instrumentation for fluids

DP-500. Target Flowmeter. Flow measurement of Gases and Liquids. Instrumentation for fluids Instrumentation for fluids Target Flowmeter Series DP-65 DP-500 Flow measurement of Gases and Liquids Metallic construction. Operates horizontally or vertically DN-80 to DN-500 Flow rate: - Water: 1.5

More information

DP-500. Target Flowmeter. Flow measurement of Gases and Liquids. Instrumentation for fluids

DP-500. Target Flowmeter. Flow measurement of Gases and Liquids. Instrumentation for fluids UK / Europe Office Tel: +44 (0)8700 434040 Fax: +44 (0)8700 434045 info@omniinstruments.co.uk www.omniinstruments.co.uk Australia / Asia Pacific Office Tel +61 (0)282 442 363 Fax +61 (0)294 751 278 info@omniinstruments.com.au

More information

Self-operated Temperature Regulators Series 43 Temperature Regulators Type 43-1 Type 43-2

Self-operated Temperature Regulators Series 43 Temperature Regulators Type 43-1 Type 43-2 Self-operated Temperature Regulators Series 43 Temperature Regulators Type 43- Type 43-2 Application Regulators for district heating supply systems, heat generators, heat exchangers, and other building

More information

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications Force Pressure Temperature Switch Pressure sensors Ex ia I / IIC T6 acc. to ATEX with internal diaphragm with front flush diaphragm Accuracy: 0,25% and 0,5 % Standard output: 4...20 ma; 2-wire system Description

More information

Technical Data. General specifications. Rated operating distance s n 5 mm

Technical Data. General specifications. Rated operating distance s n 5 mm 0102 Model Number Features 5 mm non-flush Usable up to SIL 2 acc. to IEC 61508 Technical Data specifications Switching function Normally closed (NC) Output type NAMUR Rated operating distance s n 5 mm

More information

Inductive slot sensor

Inductive slot sensor 0102 Model Number Features 2 mm slot width Technical Data specifications Switching function Normally closed (NC) Output type NAMUR Slot width 2 mm Depth of immersion (lateral) 5... 7 mm, typ. 6 mm Output

More information

Type 5347 (TR/STL), Type 5348 (TR/ST) and Type 5349 (STM/STL) Double Thermostats

Type 5347 (TR/STL), Type 5348 (TR/ST) and Type 5349 (STM/STL) Double Thermostats Thermostats Type 343 Safety Temperature Monitor (STM) Type 344 Temperature Regulator (TR) Type 34 Safety Temperature Limiter (STL) Type 347 (TR/STL), Type 348 (TR/ST) and Type 349 (STM/STL) Double Thermostats

More information

PEPPERL+FUCHS GmbH

PEPPERL+FUCHS GmbH Comfort series 1.5 mm embeddable M8x1 4 25 16 13 LED Switching element function NAMUR NC Rated operating distance s n 1,5 mm Installation embeddable Assured operating distance s a 0... 1,215 mm Reduction

More information

Catalog. Self-operated Regulators Volume 2 Temperature Regulators

Catalog. Self-operated Regulators Volume 2 Temperature Regulators Catalog Self-operated Regulators Volume 2 Temperature Regulators Self-operated Regulators Temperature Regulators Volume 2 Catalog 2012 Overview Self-operated Temperature Regulators 5 Self-operated Pressure

More information

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm 0102 Model Number Features 5 mm flush Usable up to SIL 3 acc. to IEC 61508 Application Danger! In safety-related applications the sensor must be operated with a qualified fail safe interface from Pepperl+Fuchs,

More information

SITRANS T. SITRANS T Explosion protected temperature sensor. General information. Marking of the degree of protection. Range of uses.

SITRANS T. SITRANS T Explosion protected temperature sensor. General information. Marking of the degree of protection. Range of uses. General information 1 Marking of the degree of protection 2 SITRANS T SITRANS T Explosion protected temperature sensor Operating Instructions Range of uses 3 Installation 4 Assembly and disassembly 5 Commissioning

More information

KHA6-GT*-Ex1. Thermocouple trip amplifiers. Composition. Hazardous area. Safe area. Function. 230 V AC 1-channel. Input EEx ia IIC

KHA6-GT*-Ex1. Thermocouple trip amplifiers. Composition. Hazardous area. Safe area. Function. 230 V AC 1-channel. Input EEx ia IIC Thermocouple trip amplifiers KHA6GT*Ex1 23 V AC 1channel Input EEx ia IIC Cold junction compensation 2 switching points operate on 2 output relays High/low alarm can be selected for each switching point

More information

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm 0102 Model Number Features 5 mm non-flush Usable up to SIL2 acc. to IEC 61508 Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 5 mm Installation non-flush

More information

Beck. The differential pressure transmitter for air

Beck. The differential pressure transmitter for air Beck. The differential pressure transmitter for air Differential pressure transmitter 984 General description The differential pressure transmitters of the 984 series are used to measure differential pressure,

More information

Gas cylinder scale Model GCS-1

Gas cylinder scale Model GCS-1 Electronic pressure measurement Gas cylinder scale Model GCS-1 WIKA data sheet PE 87.19 Applications Level measurement of liquid gases in gas cabinets and gas distribution systems Level measurement in

More information

Technical Data. Dimensions

Technical Data. Dimensions 0102 Model Number Features 5 mm flush Usable up to SIL2 acc. to IEC 61508 Accessories EXG-18 Quick mounting bracket with dead stop BF 18 Mounting flange, 18 mm Technical Data specifications Switching element

More information

Safety instructions VEGADIF DF65.GX*****H/Z/P/F***** IECEx BVS

Safety instructions VEGADIF DF65.GX*****H/Z/P/F***** IECEx BVS Safety instructions VEGADIF DF65.GX*****H/Z/P/F***** IECEx BVS 10.0008 Ex td A20, A20/21, A20/22, A21 IP66 T 0044 37675 Contents 1 Area of applicability 3 2 General information 3 2.1 Zone 20 instruments

More information

Technical Data. General specifications Switching element function Rated operating distance s n 8 mm

Technical Data. General specifications Switching element function Rated operating distance s n 8 mm 0102 Model Number Features 8 mm non-flush Usable up to SIL 3 acc. to IEC 61508 Application Danger! In safety-related applications the sensor must be operated with a qualified fail safe interface from Pepperl+Fuchs,

More information

Technical Data. Dimensions

Technical Data. Dimensions 0102 Model Number Features 8 mm non-flush Stainless steel housing Usable up to SIL2 acc. to IEC 61508 Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 8 mm

More information

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20 Electronic Pressure Measurement Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20 Applications Chemical, Petrochemical

More information

Technical Data. Dimensions

Technical Data. Dimensions 0102 Model Number Features Comfort series 50 mm non-flush Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 50 mm Installation non-flush Output polarity NAMUR

More information

RTK Instruments Limited St James Business Park, Knaresborough, North Yorkshire, England. HG5 8PJ

RTK Instruments Limited St James Business Park, Knaresborough, North Yorkshire, England. HG5 8PJ Operating Instructions RTK Instruments Limited Telephone: 44 (0)1423 580500 Facsimile: 44 (0)1423 580501 DA135 Intrinsically Safe LED Beacon Introduction This manual provides the information necessary

More information

Connection. e. g. Pt100. reference limit. yellow Output I. Composition

Connection. e. g. Pt100. reference limit. yellow Output I. Composition Trip amplifiers for Pt1, Ni1 KFD2GREx1 Connection e. g. Pt1 Input EEx ia IIC 1+ 2 3 Hazardous area 1channel Input EEx ia IIC 2 switching points operate on 2 output relays High/low alarm can be selected

More information

Level gauges Series LS Level indicator, switch and transmitter for liquids

Level gauges Series LS Level indicator, switch and transmitter for liquids Level gauges Series LS Level indicator, switch and transmitter for liquids Simple construction Resistant under extreme temperature and pressure conditions No risk of leakage Measuring range: from 150 mm

More information

Inductive Conductivity Measurement. Simultaneous display of conductivity/ resistance/salinity and temperature; large measurement symbol.

Inductive Conductivity Measurement. Simultaneous display of conductivity/ resistance/salinity and temperature; large measurement symbol. Process Analysis Systems Chem Energy Pharm Food Water Stratos Eco 2405 CondI Inductive Conductivity Measurement Simultaneous display of conductivity/ resistance/salinity and temperature; large measurement

More information

Level Measurement Continuous level measurement Ultrasonic transmitters

Level Measurement Continuous level measurement Ultrasonic transmitters Overview Configuration is a short-range integrated ultrasonic level transmitter. This intrinsically safe, 2 wire, 4 to 20 ma loop powered transmitter is ideal for liquids, slurries, and bulk materials

More information

R Air flows from high pressure side to low pressure side. This principle can be applied to keep clean-air in the room or, alternatively, not to leak p

R Air flows from high pressure side to low pressure side. This principle can be applied to keep clean-air in the room or, alternatively, not to leak p The first edition contrasted April 2011 Yamamoto Electric Works Co.,Ltd. T H E G E N E R A L C A T A L O G R We appreciate the importance of air. Manostar gage h t t p : / / w w w. m a n o s t a r. c o.

More information

Technical Data. Dimensions

Technical Data. Dimensions 0102 Model Number Features 15 mm non-flush Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 15 mm Installation non-flush Assured operating distance s a 0...

More information

VERSAFLOW VORTEX Supplementary instructions

VERSAFLOW VORTEX Supplementary instructions VERSAFLOW VORTEX Supplementary instructions Vortex flowmeter Equipment category II 2G CONTENTS VERSAFLOW VORTEX 1 Safety instructions 3 1.1 General notes... 3 1.2 EC conformity... 3 1.3 Approval according

More information

Dissolved Oxygen Measurement liquisys M COM 223 / 253

Dissolved Oxygen Measurement liquisys M COM 223 / 253 Technical Information TI 199C/24/ae Dissolved Oxygen Measurement liquisys M COM 223 / 253 Oxygen Controller Benefits at a glance Liquisys M COM 223 Liquisys M COM 253 Due to the modularity of its design,

More information

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm 0102 Model Number Features Direct mounting on standard actuators EC-Type Examination Certificate TÜV99 ATEX 1479X Accessories BT32 BT32XS BT32XAS BT33 BT34 V1-G-N4-5M-PUR Female cordset, M12, 4-pin, NAMUR,

More information

Dissolved Oxygen Measurement liquisys S COM 223 / 253

Dissolved Oxygen Measurement liquisys S COM 223 / 253 Technical Information TI 199C/07/en No. 51500281 Dissolved Oxygen Measurement liquisys S COM 223 / 253 Oxygen Transmitter Benefits at a glance Measuring transmitter in field or panel-mounted housing Universal

More information

Ar-Mite TM Low Flow Armored Flowmeter

Ar-Mite TM Low Flow Armored Flowmeter Data Sheet Brooks Ar-Mite TM MT 3750C Ar-Mite TM Low Flow Armored Flowmeter Ar-Mite TM Model MT 3750 Metal Tube Flowmeter Ar-Mite TM Model MT 3750 Metal Tube Flowmeter with Transmitter or Inductive Alarm

More information

Ultrasonic Level Measurement nivopuls FDU 10 S

Ultrasonic Level Measurement nivopuls FDU 10 S Technical Information TI 275F/00/en Ultrasonic Level Measurement nivopuls FDU 10 S Level limit switch for liquids with separate electronics unit Non-contact from outside Suitable for use in explosion hazardous

More information

Dissolved Oxygen Analyzers

Dissolved Oxygen Analyzers FEATURES DESCRIPTION The model 223 Dissolved Oxygen Transmitter measures dissolved oxygen over the range of 0 to 20mg/l or 0 to 200% saturation. The basic transmitter is available with either a 115VAC,

More information

SBEx-4 BISTATE SEPARATOR 1, 2, 3 or 4 channels in rail housing (TS35, 22,5mm width)

SBEx-4 BISTATE SEPARATOR 1, 2, 3 or 4 channels in rail housing (TS35, 22,5mm width) SBEx-4 BISTATE SEPARATOR,, 3 or 4 channels in rail housing (TS3,,mm width) - group I category (M), group II and III category () accompanying device, - intrinsically safe input circuits with ia protection

More information

Level Measurement. Point level measurement Capacitance switches. Pointek CLS100. Overview. Configuration

Level Measurement. Point level measurement Capacitance switches. Pointek CLS100. Overview. Configuration Level Measurement Siemens AG 2012 Overview Configuration Installation Standpipes 0 (2) 20 (0.79) max. is a compact 2-wire inverse frequency shift capacitance switch for level detection in constricted spaces,

More information

Instrumentation Products and Applications

Instrumentation Products and Applications 1 1/0 Instrumentation Products and Applications 1 Instrumentation Safety barriers I.S. Isolators - DIN rail mounting - Eurocards - Modules Remote I/O Operating and monitoring systems Instrumentation systems

More information

COMPACT FLAME CONTROLLER CFC 200 (Formerly 8.XX)

COMPACT FLAME CONTROLLER CFC 200 (Formerly 8.XX) COMPACT FLAME CONTROLLER CFC 200 (Formerly 8.XX) TECHNICAL DESCRIPTION EDITION: TB CFC200-REV3-2015-04-07 IMPORTANT: Please note, that all mounting and wiring as well as all changing or adjustment at the

More information

Inductive Conductivity

Inductive Conductivity Inductive Conductivity THORNTON Leading Pure Water Analytics 7100E Non-Fouling Sensors PEEK or PFA Wetted Parts Excellent Chemical Resistance 0/4 to 20mA Outputs for Conductivity & Tempreature 4 Relays

More information

Hygro and Hygrothermo Transducers (capacitive) for climatic applications

Hygro and Hygrothermo Transducers (capacitive) for climatic applications Data sheet 907020 Page 1/7 Hygro and Hygrothermo Transducers (capacitive) for climatic applications To measure relative humidity and temperature For versatile climatic applications and ventilation For

More information

Operating Instructions for Limit switch Model: NBK-R NBK-RM NBK-RT NBK-RA

Operating Instructions for Limit switch Model: NBK-R NBK-RM NBK-RT NBK-RA Operating Instructions for Limit switch Model: NBK-R NBK-RM NBK-RT NBK-RA 1. Contents 1. Contents... 2 2. Note... 3 3. Instrument Inspection... 3 4. Regulation Use... 3 4.1 Electrical limit switch... 4

More information

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i. Additional Operating Instructions SITRANS F Vortex flowmeters Ex-i Edition 09/2018 CONTENTS 1 Safety instructions 3 1.1 General notes... 3 1.2 EU conformity... 3 1.3 Approval according to the IECEx scheme...

More information

Fire & Security Products. Siemens Building Technologies Group

Fire & Security Products. Siemens Building Technologies Group Fire & Security Products Siemens Building Technologies Group . 1 Brief overview.................................................... 1 1.1 Characteristics....................................................

More information

Model 144H. Product Data Sheet , Rev DB February Content

Model 144H. Product Data Sheet , Rev DB February Content Rosemount 144 PC-Programmable Temperature Transmitter Provides an installation-ready solution for temperature monitoring applications using Complete Point Solutions (CPS) Increases measurement accuracy

More information

OPTIBAR P 1010/2010 C Supplementary instructions

OPTIBAR P 1010/2010 C Supplementary instructions OPTIBAR P 1010/2010 C Supplementary instructions Pressure transmitter Equipment category II 1G / Ga, II 1D / Da in protection type intrinsic safety Exi KROHNE CONTENTS OPTIBAR P 1010/2010 C 1 Safety instructions

More information

Installation and operation manual DPC200 - DIFFERENTIAL PRESSURE CONTROLLER. Low pressure with PI-control-mode

Installation and operation manual DPC200 - DIFFERENTIAL PRESSURE CONTROLLER. Low pressure with PI-control-mode Installation and operation manual DPC200 - DIFFERENTIAL PRESSURE CONTROLLER Low pressure with PI-control-mode Manufacturer: Phone: Fax: E-Mail: Website: Issue: Doc.-no.: Arthur Grillo GmbH Am Sandbach

More information

Level instruments. Point level measurement - Capacitance switches. Pointek CLS100 5/9. Overview. Configuration

Level instruments. Point level measurement - Capacitance switches. Pointek CLS100 5/9. Overview. Configuration Level instruments Overview Configuration is a compact 2-wire inverse frequency shift capacitance switch for level detection in constricted spaces, interfaces, solids, liquids, slurries and foam. Benefits

More information

Mounting and Operating Instructions EB 2231 EN

Mounting and Operating Instructions EB 2231 EN Self-operated Regulators Thermostats Type 223 and Type 2232 Bulb Sensors Type 2233, Type 2234, and Type 2235 Air Sensors Type 223 with bulb sensor Type 2232 with bulb sensor (separate) Type 2233 with air

More information

Differential pressure sensors

Differential pressure sensors 1 916 1916P01 1916P03 QBM65-..., QBM65.2-... QBM65.1-... Differential ressure sensors for air and nonaggressive gases QBM65... With choice of ressure-linear or extracting-the-root characteristic with adjustable

More information

Technology for life. Unit heater LH

Technology for life. Unit heater LH Technology for life. Unit heater 1 2 Contents Contents... Page Basic unit: casing, fan, motors... 4 Basic unit: heat exchanger... 5 Performance tables 25...6-7 Performance tables 40...8-9 Performance tables

More information

Differential pressure gauge with electrical contact type Model: P650 series

Differential pressure gauge with electrical contact type Model: P650 series Differential pressure gauge with electrical contact type Model: P650 series Service intended The P650 series are designed to measure a differential pressure from 25 kpa to 2.0 MPa at static pressure up

More information

UV Flame Supervision System

UV Flame Supervision System 7 783 UV Flame Supervision System DETACTOGYR LFE50 Series 02 ISO 9001 The LFE50 is a self-checking UV flame supervision system designed for use with continuously operating burners or for burners running

More information

Flow Measurement SITRANS F C

Flow Measurement SITRANS F C Overview The flow measuring principle is based on the Coriolis Effect. The FCS sensor s measuring tubes are energized by an electromechanical driver circuit which oscillates them at their resonance frequency.

More information

DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor

DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor DSF xx15.xx xhv Ex-Atex Product ID Type # Product # Drawing # DSF 1215.01 SHV Ex-atex (5m) 304Z-05197 113216 DSF 1415.01 AHV Ex-atex S148 304Z-05256 113351 DSF 1615.01 SHV Ex-atex (5m) 304Z-05196 113214

More information

SENSOR O2 O2-A

SENSOR O2 O2-A Item Inquiry Vian code Description QNY Manufacturer 1 7 10359 disposable O sensor SPXCDXSO1SS senspoint XCD 6 honeywell 104 136540 Sensor Gas,Gasmonitor 0-5 No:09737 1 Bieler+Lang 1 104 136543 SENSOR O

More information

SP-2400 & 2410 Series Smart Valve Positioner (Linear & Rotary)

SP-2400 & 2410 Series Smart Valve Positioner (Linear & Rotary) SP-2400 & 2410 series Positioner are the advanced smart valve positioners which provide easy installation and simple setting and offer the automation systems outstanding reliability in control performance

More information

Level Measurement. Point level measurement - Capacitance switches. Pointek CLS100. 5/10 Siemens FI Overview.

Level Measurement. Point level measurement - Capacitance switches. Pointek CLS100. 5/10 Siemens FI Overview. Siemens AG 00 Overview Configuration Installation Standpipes 0 () 0 (0.79) max. Wall Restriction is a compact -wire inverse frequency shift capacitance switch for level detection in constricted spaces,

More information

Model 144H. Product Data Sheet , Rev DB February Content

Model 144H. Product Data Sheet , Rev DB February Content Rosemount 144 PC-Programmable Temperature Transmitter Provides an installation-ready solution for temperature monitoring applications using Complete Point Solutions (CPS) Increases measurement accuracy

More information

Continuous Gas Analyzers, extractive

Continuous Gas Analyzers, extractive Siemens AG 007 Continuous Gas Analyzers, extractive CALOMAT 6 General Overview Plug-in and field device The CALOMAT 6 gas analyzer is primarily used to identify a gas component quantity (e.g. H, N, Cl,

More information

RADAR LEVEL GAUGE SPECIAL SAFETY INSTRUCTION

RADAR LEVEL GAUGE SPECIAL SAFETY INSTRUCTION Special Safety Instruction en RADAR LEVEL GAUGE SPECIAL SAFETY INSTRUCTION Contents TankRadar Pro European ATEX Directive Information............................... 2 ATEX marking and Ex Certification

More information

DICTATOR Hold-Open Systems for Hazardous Areas

DICTATOR Hold-Open Systems for Hazardous Areas DICTATOR for Hazardous Areas Products to be used in hazardous areas obviously have to meet special demands. The European ATEX directives (first the EN 94/9/EG and then the directive 2014/34/ EU) brought

More information

InductIve SenSorS 2018

InductIve SenSorS 2018 InductIve SenSorS 2018 RoHS Compliant Registration No.: 1327-01 For all transactions, the newest version of the General Conditions of Sale and Delivery for Products and Services of the Electrical Industry

More information

QAF64.2-J QAF64.6-J. Frost detector. for use on the air side

QAF64.2-J QAF64.6-J. Frost detector. for use on the air side s Frost detector for use on the air side QAF64.2-J QAF64.6-J With active capillary tube sensing element for acquiring the lowest temperature within a range of 0 15 C With startup function Operating voltage

More information

Druck DPI 705/DPI 705 IS Series

Druck DPI 705/DPI 705 IS Series GE Sensing & Inspection Technologies 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Druck DPI 705/DPI 705 IS Series Digital Pressure

More information

OPTIBAR DP 7060 Supplementary Instructions

OPTIBAR DP 7060 Supplementary Instructions OPTIBAR DP 7060 Supplementary Instructions Differential pressure transmitter Category ATEX II 1/2G, 2G Ex db ia IIC T6...T1 Ga/Gb, Gb IECEx Ex db ia IIC T6...T1 Ga/Gb, Gb Housing Aluminium: Single chamber,

More information

FSW300 Series Flow Switch

FSW300 Series Flow Switch . FSW300 Series Flow Switch - 2 - Series FSW300 Series FSW300 Table of contents page 0 About this operating manual... 4 1 Device description... 5 1.1 Intended use... 5 1.1.1 Reed contact - Switching of

More information

Process Protection. 6/2 Overview. 6/3 Acoustic and motion sensing. Acoustic sensors for pump monitoring 6/5 SITRANS DA400 acoustic diagnostic unit

Process Protection. 6/2 Overview. 6/3 Acoustic and motion sensing. Acoustic sensors for pump monitoring 6/5 SITRANS DA400 acoustic diagnostic unit Siemens AG 2017 /2 Overview /3 Acoustic and motion sensing Acoustic sensors for pump monitoring /5 SITRANS DA400 acoustic diagnostic unit Acoustic sensors for material flow monitoring /10 SITRANS AS100

More information

Thermostatic head K. with contact or immersion sensor. Thermostat-Köpfe For medium temperature control

Thermostatic head K. with contact or immersion sensor. Thermostat-Köpfe For medium temperature control Thermostatic head K with contact or immersion sensor Thermostat-Köpfe For medium temperature control IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Thermostatic head K with contact or immersion

More information

Rod probe 11961Z. Technical Information. Conductive level limit detection Partially insulated rod probe for use in conductive liquids

Rod probe 11961Z. Technical Information. Conductive level limit detection Partially insulated rod probe for use in conductive liquids Technical Information Rod probe 11961Z Conductive level limit detection Partially insulated rod probe for use in conductive liquids Application Conductive level limit detection in process or storage tanks

More information

Temperature Measurement Transmitters for field mounting

Temperature Measurement Transmitters for field mounting Siemens AG 07 Overview Application The SITRANS TF can be used everywhere where temperatures need to be measured under particularly harsh conditions. For that reasons users from all industries have opted

More information

WIO200 Water In Oil measuring instrument

WIO200 Water In Oil measuring instrument WIO200 Water In Oil measuring instrument You have made the right decision by choosing a measuring instrument from PAJ Systemteknik. Many customers buy our high standard products every year. There are at

More information

Temperature controller AVT with safety temperature monitor STM / VGS for steam (PN 25)

Temperature controller AVT with safety temperature monitor STM / VGS for steam (PN 25) Data sheet Temperature controller AVT with safety temperature monitor STM / VGS for steam (PN 25) Description STW871 The controllers are: - Type-tested acc. to EN 14597 and protect against exceeding temperatures:

More information

Gas expansion thermometer

Gas expansion thermometer Gas expansion thermometer Type series FN. Features High quality case with bajonet ring /160, degree of protection IP 66 Nominal ranges -40 C 700 C, further nominal ranges from -200 C...700 C upon request

More information

PROCESS AUTOMATION PRECISE VALUES LEVEL MEASUREMENT TECHNOLOGY

PROCESS AUTOMATION PRECISE VALUES LEVEL MEASUREMENT TECHNOLOGY PROCESS AUTOMATION PRECISE VALUES LEVEL MEASUREMENT TECHNOLOGY POINT LEVEL DETECTION In applications like overfill protection, min/max control, or overflow and dry-run protection, the limit value switches

More information

Flow switch. Operating Manual. English manual page Page 1 of 15 Fax:

Flow switch.   Operating Manual. English manual page Page 1 of 15 Fax: Operating Manual www.jlso-tec-trade.de Flow switch English manual page 1-15 Page 1 of 15 Flow switch Table of Contents Page 1 Device Description and Intended Use... 19 1.1 Flow switch version VH...X...

More information

DP86 Constant Voltage with Fitting

DP86 Constant Voltage with Fitting SPECIFICATIONS 316L SS Wet/Wet Differential Low Pressure 0 100mV Output The DP86 constant voltage with fitting differential pressure sensor is a double-sided, media compatible, piezoresistive silicon pressure

More information

02/11/2015

02/11/2015 CTH 46 - CTD 43 / 46 CTD 46 Part number 89422108 CTH 46 Heating / cooling function Measurement and setpoint display CTD 43 Heating or cooling function Measurement display Measurement deviation display-setpoint

More information

EN - english. Instructions for installation and operation. Mobile humidity meter DP 207

EN - english. Instructions for installation and operation. Mobile humidity meter DP 207 EN - english Instructions for installation and operation Mobile humidity meter DP 207 Dear customers, Thank you very much for deciding in favour of the mobile humidity measuring instrument DP 207. Please

More information

PH / ORP Analyzers MODEL OPM223/253. Wedgewood Analytical Inc. Liquid Analytical Measurement & Control Specialists DESCRIPTION FEATURES APPLICATIONS

PH / ORP Analyzers MODEL OPM223/253. Wedgewood Analytical Inc. Liquid Analytical Measurement & Control Specialists DESCRIPTION FEATURES APPLICATIONS FEATURES DESCRIPTION The model 223pH / ORP Transmitter is ideal for use where economy and reliability are the prime considerations. The basic transmitter is available with either a 115VAC, 220VAC or 24V

More information

Brooks MT3750 Low Flow Armored Flowmeter

Brooks MT3750 Low Flow Armored Flowmeter Brooks MT3750 Low Flow Armored Flowmeter ArMite TM Model MT3750 Metal Tube Flowmeter ArMite TM Model MT3750 Metal Tube Flowmeter with Transmitter or Inductive Alarm Benefits: Wetted Parts made from Stainless

More information

FAHM Co. Temperature Transmitter PTT74 Series

FAHM Co. Temperature Transmitter PTT74 Series FAHM Co. PTT74 Series The PTT74 is a versatile temperature transmitter that delivers field reliability and advanced accuracy and stability to meet demanding process needs. PTT74 Family of Transmitters

More information

Level Electrode NRG Original Installation Instructions English

Level Electrode NRG Original Installation Instructions English Level Electrode NRG 16-36 EN English Original Installation Instructions 819257-01 Contents Contents Page Important notes Usage for the intended purpose...4 Function...4 Safety note...4 Directives and standards

More information

Level Electrode NRG NRG Original Installation Instructions English

Level Electrode NRG NRG Original Installation Instructions English Level Electrode NRG 10-52 NRG 16-52 EN English Original Installation Instructions 819123-02 Contents Important notes Page Usage for the intended purpose...4 Function...4 Safety note...4 Directives and

More information

GESTRA Steam Systems LRG English. Installation Instructions Conductivity Electrode

GESTRA Steam Systems LRG English. Installation Instructions Conductivity Electrode GESTRA Steam Systems LRG 16-9 EN English Installation Instructions 818867-00 Conductivity Electrode LRG 16-9 Contents Important Notes Page Usage for the intended purpose...4 Safety Notes...4 Danger...4

More information

89BSD Digital Output

89BSD Digital Output SPECIFICATIONS Stainless Steel with O-Ring Seal Pressure/Temperature Read-Out (24-bit DS ADC) ASIC Calibrated Absolute, Sealed Gage 9mm Diameter The 89BSD is a 9mm diameter small profile, media compatible,

More information

The A-series Eletta Flow Monitor with local indication and analog output

The A-series Eletta Flow Monitor with local indication and analog output The A-series Eletta Flow Monitor with local indication and analog output GL series FA series GSS series FSS series The Pipe Section is constructed of copper alloy and fitted with BSP/NPT threads from 15

More information

Instruction Manual. Model 6553 Series (ATEX) Gas Analyser Systems for Intrinsically Safe Hydrogen & Purge Gas Purity Measurement

Instruction Manual. Model 6553 Series (ATEX) Gas Analyser Systems for Intrinsically Safe Hydrogen & Purge Gas Purity Measurement Zero Zero Model 6553 Series (ATEX) Gas Analyser Systems for Intrinsically Safe Hydrogen & Purge Gas Purity Measurement Instruction Manual Digital Displays 4689 500/501 and 4689 500/503Models %H2 IN AIR

More information

Vacuum Switch, Differential Pressure Adapter, Switching Amplifier

Vacuum Switch, Differential Pressure Adapter, Switching Amplifier Operating Manual Incl. EU Declaration of Conformity Vacuum Switch, Differential Pressure Adapter, Switching Amplifier VSC150, SV tina42e1-b (2017-03) 1 Product Identification In all communications with

More information

MODEL: 47LT. Digital Panel Meters 47 Series. [3] DISPLAY COLOR R: Red YR: Orange G: Green BG: Bluegreen B: Blue W: White. [4] POWER INPUT AC Power

MODEL: 47LT. Digital Panel Meters 47 Series. [3] DISPLAY COLOR R: Red YR: Orange G: Green BG: Bluegreen B: Blue W: White. [4] POWER INPUT AC Power Digital Panel Meters 47 Series THERMOCOUPLE INPUT DIGITAL PANEL METER (4-digit, LED display type) Functions & Features 4-digit thermocouple input digital panel meter 1/8 DIN size Moving average function

More information

QAF63.2 QAF63.6. Frost sensors for use on the air side. Building Technologies HVAC Products

QAF63.2 QAF63.6. Frost sensors for use on the air side. Building Technologies HVAC Products 1 821 1821P01 Frost sensors for use on the air side Active capillary tube sensor for measuring the lowest temperature within a range of 0 15 C Operating voltage AC 24 V Signal output DC 0...10 V Use On

More information

System components for sample gas conditioning Sample gas cooler, gas feed unit, converter, accessories

System components for sample gas conditioning Sample gas cooler, gas feed unit, converter, accessories Data sheet 0/3-5.0 EN Rev. 5 System components for sample gas conditioning Sample gas cooler, gas feed unit, converter, accessories Measurement made easy SCC-C Sample gas cooler SCC-F Sample gas feed unit

More information

CO warning instruments and gas spillage detectors

CO warning instruments and gas spillage detectors CO warning instruments and gas spillage detectors For safety & service testo 315-1 testo 315-2 CO testo 317-3 testo 317-1 testo 315-1 Versatile CO measurement For safety and service testo 315-1 CO warning

More information

Engineering Guideline. pac-carriers Type for Yokogawa ProSafe-RS

Engineering Guideline. pac-carriers Type for Yokogawa ProSafe-RS Engineering Guideline pac-carriers Type 9195 for Yokogawa ProSafe-RS 2 Engineering Guideline / Yokogawa ProSafe-RS 06.06.2017 Integrated solutions for Yokogawa R. STAHL offers a wide range of customized

More information

Instruction Manual September 2010 SITRANS LVL200S

Instruction Manual September 2010 SITRANS LVL200S Instruction Manual September 2010 SITRANS LVL200S Contents Contents 1 About this document 1.1 Function.................................. 4 1.2 Target group.............................. 4 1.3 Symbolism

More information

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA.

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA. Additional Operating Instructions SITRANS F Vortex flowmeters Ex-nA Edition 08/207 CONTENTS Safety instructions 3. General notes... 3.2 EU conformity... 3.3 Approval according to the IECEx scheme... 3.4

More information

SITRANS Pressure transmitter SITRANS LH300 (7MF1575..) Transmitter for hydrostatic level Compact Operating Instructions

SITRANS Pressure transmitter SITRANS LH300 (7MF1575..) Transmitter for hydrostatic level Compact Operating Instructions SITRANS Pressure transmitter Compact Operating Instructions Legal information Warning notice system This manual contains notices you have to observe in order to ensure your personal safety, as well as

More information

industrial electronics electronic level measurement system

industrial electronics electronic level measurement system industrial electronics electronic level measurement system Table of content About company Continuous level meters ULM 70 ULM 53 HLM 25, HLM 16 CLM 36 Limit level sensors DLS 27 FLD 48 "Meduse" CLS 18 CLS

More information