Tamper & Weather Resistant Receptacles
|
|
- Amanda Franklin
- 5 years ago
- Views:
Transcription
1 Tamper & eather esistant Tamper esistant eather esistant Tamper & eather esistant eceptacles Proven safety solutions for compliance with 2011 National Electrical Code requirements
2 2011 NEC eceptacle equirements Code compliant protection from electrical injury The 2011 National Electrical Code has been updated to ensure proper receptacle safety in Dwelling Units, uest Suites, and Child Care facilities NEC equirements for eceptacles Tamper esistant eceptacles in Dwelling Units All non-locking type 15A and 20A, 125V receptacles in a dwelling unit (210.52) must be Listed as Tamper esistant, excluding the following locations: eceptacles located more than 5 ½ ft above the floor eceptacles that are part of a luminaire or appliance eceptacles located within dedicated space for an appliance that in normal use isn t easily moved Non-grounding receptacles used for replacements as permitted in 406.4(D)(2)(a) Each year, more than 2,400 children are injured by inserting foreign objects into receptacles. According to a 10-year study of National Electronic Injury Surveillance System (NEISS) data Tamper esistant eceptacles in uest ooms and uest Suites All non-locking type 15A and 20A, 125V receptacles in guest rooms and guest suites must be Listed as Tamper esistant Tamper esistant eceptacles in Child Care Facilities All non-locking type 15A and 20A, 125V receptacles in child care facilities (406.2) must be Listed as Tamper esistant eather esistant eceptacles All 125 and 250 volt, 15 and 20 ampere non-locking receptacles shall be Listed as weather resistant type in damp and wet locations. eather protective covers alone do not guarantee protection against potential exposure; in damp and wet locations weather resistant receptacles in weather protective covers must be used. Outdoor weather resistant receptacles must provide resistance to temperature extremes, excessive ultraviolet light and the effects of aging. UL Listed devices must have a marking clearly visible when installed. Tamper esistant T mold mark provides quick visual confirmation of tamper resistance when installed. Tamper & eather esistant Both the T mold mark and identifier are clearly visible in the finished installation, indicating double-layer protection for maximum safety. eather esistant identifier quickly indicates during inspections that a weather resistant device has been installed.
3 Tamper esistant eceptacles Tamper esistant receptacles feature a built-in UL Listed safety shutter system that prevents the insertion of foreign objects into the receptacle openings. The safety shutters will only open when a two-bladed plug presses simultaneously against the two shutters. Tamper esistant T eceptacle Internal Components: eceptacle openings are restricted by internal shutters (show above). Blocked Insertion: Insertion of object in any one side will not open shutters. Successful Insertion: Insertion of two-bladed plug at the same time will open shutters. eather esistant eceptacles eather esistant receptacles offer protection from rain, snow, ice, moisture, & humidity when properly eather esistant installed in an approved weather protective or while-in-use cover. The design of the eather esistant receptacles is distinctive because of the durable nylon housing and corrosion resistant metal components. Combine receptacles with any of our eatherboxtm hile-in-use Protective Covers for tough protection against the elements in any residential or commercial outdoor application. eather esistant eceptacles with corrosion resistant metal components eatherbox Cast Aluminum hile-in-use Protective Cover, Single-ang eatherbox Polycarbonate hile-in-use Protective Cover, Single or 2-ang Tamper & eather esistant eceptacles Tamper & eather esistant Tamper and eather esistant eceptacles provide both tamper resistant safety and ensure weather resistance in wet and damp outdoor locations. Areas that demand the use of Tamper & eather esistant eceptacles include: Homes & Apartments Assisted Living Facilities & etirement Communities Public Facilities & ecreational Areas 3
4 T eceptacles Project Name: Project Number: Catalog Number: Prepared By: Date: Type: T270 T1107 TC20 T " (114.3mm) 1.015" (25.8mm) 1.015" (25.8mm) 1.10" (27.9mm) 1.10" (27.9mm) Tamper esistant Tamper esistant eceptacles Single & Duplex eceptacles FEATUES Provides compliance with 2011 NEC Articles for Tamper esistant eceptacles. T designation provides visual identification. Side-wire terminals accept up to #10 solid or stranded wire. Push-in terminals accept #14 solid wire (T270, T1107, T780, & 9500T duplex devices only). 2-Pole, 3-ire 15A, 125V/AC 20A, 125V/AC Automatic grounding system eliminates need for bonding jumper in grounded metal enclosure, provides redundant measure of ground continuity where jumper used (TC only). Durable impact-resistant thermoplastic face and back body is virtually unbreakable. esidential rade, Single and Duplex 15A 125V 5-15 Duplex eceptacle T270 A, B, BK, LA, V, Duplex eceptacle, Auto rounding T270-9 A, B, BK, LA, V, Decorator Duplex eceptacle T1107 A, B, BK, Y, LA, V, Decorator Duplex eceptacle, T A, B, BK, Y, LA, V, Auto rounding Commercial rade, Single & Duplex F S * 15A 125V 5-15 Single eceptacle, Side ire T817 A, B, BK, Y, LA, V, Duplex eceptacle, Side ire TC15 A, B, BK, Y, LA, V, * Duplex eceptacle, Back & Side ire TB15 A, B, BK, Y, LA, V, Decorator Single eceptacle, Back T6250 A, B, BK, Y, LA, V, & Side ire * Decorator Duplex eceptacle, Back T6252 A, B, BK, Y, LA, V, & Side ire 20A 125V 5-20 Single eceptacle, Side ire T1877 A, B, BK, LA, V, Commercial Floor Box Duplex eceptacle, Side ire TC20 A, B, BK, Y, LA, V, * Duplex eceptacle, Back & Side ire TB20 A, B, BK, Y, LA, D,V, Decorator Single eceptacle, Back T6350 A, B, BK, Y, LA, V, & Side ire * Decorator Duplex eceptacle, Back T6352 A, B, BK, Y, LA, V, Side ire A 125V 5-15 Single Floor Box Assembly T5797 Black, Brass Assembly For ordering, include Cat. No. followed by the color code: A (Almond), B (Brown), BK (Black), Y (ray), LA (Light Almond), D (ed), V (Ivory), (hite) NAFTA Compliant C US 1.75" (44.5mm) T " (69.9mm) 3.50" (88.9mm) TESTIN & CODE COMPLIANCE culus Listed to UL498, UL943 file nos. E60120 (TVF, 9566, 9569), E15058 UL948 (all others), cul Certified to CSA C22.2, no. 42. TB, UL verified to Fed. Spec. C-596. NOM/ANSI Certified. T5797, culus File E92122, UL498 & UL514C cul to CSA C22.2 No. 18, CSA C22.2 No 42 MATEIAL CHAACTEISTICS Environmental: Flammability meets UL94 requirements; T817, T1877, T6250, T6252, T6350, T6352, TB, T270, T1107, TC V2 rated; T5797 V0 rated. Temperature ating: T270, T1107, TC: -20ºC to 60ºC (-4 F to 140 F); T817, T1877, T6250, T6252, T6350, T6352, TB: -20ºC to 70ºC (-4 F to 158 F); T5797: -40ºC to 65ºC (-40 F to 149 F) 4
5 T eceptacles Project Name: Project Number: Catalog Number: Prepared By: Date: Type: Tamper esistant FEATUES Provides compliance with 2011 NEC Articles for Tamper esistant eceptacles. T designation provides visual identification. Side-ire terminals accept up to #10 solid or stranded wire. Push-in terminals accept #14 solid wire (T270, T1107, T780, & 9500T Duplex devices only). 15A 125V 5-15 Duplex eceptacle T8200 B, Y, D, V, Duplex FCI TVFH15 B, Y, LA, D, V, 20A 125V 5-20 Duplex eceptacle T8300 B, Y, D, V, Duplex FCI TVFH20 B, Y, LA, D, V, For ordering, include Cat. No. followed by the color code: A (Almond), B (Brown), BK (Black), Y (ray), LA (Light Almond), D (ed), V (Ivory), (hite) Hospital rade Tamper esistant eceptacles Single & Duplex eceptacles Construction rade Specification rade, Combination 2-Pole, 3-ire 15A, 125V/AC 20A, 125V/AC Automatic grounding system eliminates need for bonding jumper in grounded metal enclosure, provides redundant measure of ground continuity where jumper used (Combination Devices only). Durable impact-resistant thermoplastic face and back body is virtually unbreakable. Combination LED Nightlight features dimmable nightlight that turns on in the dark and off in the light. (T7735) 15A 125V 5-15 Combination Single Pole Switch & T274 A, B, BK, LA, V, eceptacle Combination 3-ay Switch & T293 A, B, BK, LA, V, eceptacle Decorator Combination Single Pole T7730 A, BK, LA, V, & eceptacle Decorator Combination LED T7735 A, LA, V, Nightlight & eceptacle F S * 15A 125V 5-15 Duplex eceptacle T5262 B, Y, LA, V, 20A 125V 5-20 Duplex eceptacle T5362 B, Y, LA, V, 20A 125V 5-20 Combination Single Pole Switch & T291 A, B, BK, LA, V, eceptacle Specification rade, FCI A 125V 5-15 Duplex FCI TVF15 A, B, BK, Y, LA, D, V, 20A 125V 5-20 Duplex FCI TV20 A, B, BK, Y, LA, D, V, Hospital rade, eceptacles & FCI T274 T7730 T7735 T " (27.7mm) 1.20" (30.5mm) 1.015" (25.8mm) 1.64" (41.7mm) TESTIN & CODE COMPLIANCE culus Listed to UL498, UL943 file nos. E60120 (TVF), E15058 (all others), except T8200 & T8300: Listed to UL498, file no. E cul Certified to CSA C22.2, no. 42. TVF meets all UL943 and UL498 requirements. T5262, T5362, T8200/8300 UL verified to Fed. Spec. C-596. NOM/ANSI Certified. Combination devices, culus File E18704, UL20, UL498, cul File E18704, CSA 22.2 MATEIAL CHAACTEISTICS Environmental: Flammability meets UL94 requirements; T Combo Devices, TVF, T8200, T8300, 5262, 5362, V2 rated. Temperature ating: T Combo Devices: -20ºC to 60ºC (-4 F to 140 F); TVF: -35ºC to 66ºC (-31 F to F); T8200, T8300: -40 C to 60 C (-40 F to 140 F); 5262, 5362: -20 C to 70 C (-4 F to 158 F). TVF " (41.7mm) 5
6 & T eceptacles Project Name: Project Number: Catalog Number: Prepared By: Date: Type: B " (27.7mm) eather esistant Tamper & eather esistant Duplex eceptacles eather esistant and Tamper & eather esistant eceptacles FEATUES Nickel-plated strap & mounting screws, and stainless steel terminal screws for corrosion resistance. Provides compliance with 2011 NEC Article that states that all receptacles installed in wet and damp locations must be weather resistant. Manufactured with the highest grade of materials; durable impact-resistant thermoplastic face and back body is virtually unbreakable. 2-Pole, 3-ire 15A, 125V/AC 20A, 125V/AC T and designations provide visual identification. Terminal screws are backed out and ready to wire. Patented built-in wire stripper for #14 and #12 wire to speed installation. Side-wire terminals accept up to #10 solid or stranded wire. Push-in terminals accept #14 solid wire (T270 only). VF " (30.5mm) Commercial rade, Duplex C US F S A 125V 5-15 Duplex eceptacle, Back & Side ire B15 B, Y, V, 20A 125V 5-20 Duplex eceptacle, Back & Side ire B20 B, Y, V, Specification rade FCI 15A 125V 5-15 Duplex FCI VF15 B, Y, V, 20A 125V 5-20 Duplex FCI V20 B, Y, V, C US 426 T " (25.8mm) T esidential rade, Duplex 15A 125V 5-15 Duplex eceptacle T270 LA, V, T Commercial rade, Duplex C US F S A 125V 5-15 Duplex eceptacle, Back & Side ire TB15 B, Y, V, 20A 125V 5-20 Duplex eceptacle, Back & Side ire TB20 B, Y, V, TVF " (41.7mm) T Specification rade, FCI 15A 125V 5-15 Duplex FCI TVF15 B, Y, LA, V, 20A 125V 5-20 Duplex FCI TV20 B, Y, LA, V, For ordering, include Cat. No. followed by the color code: B (Brown), Y (ray), LA (Light Almond), V (Ivory), (hite) TESTIN & CODE COMPLIANCE culus Listed to UL498. cul Certified to CSA C22.2, no. 42. VF & TVF meet all UL943 (FCI) and UL498 (eceptacles) requirements. B and TB UL verified to Fed. Spec. C-596. NOM/ANSI Certified. MATEIAL CHAACTEISTICS Environmental: Flammability meets UL94 requirements; T270 V2 rated; VF, B, TB, TVF V2 rated. Temperature ating: T270: -20ºC to 60ºC (-4 F to 140 F); VF, TVF: -35ºC to 66ºC (-31 F to 151 F); B, TB: -20ºC to 70ºC (-4 F to 158 F). 6
7 T eceptacles Project Name: Project Number: Catalog Number: Prepared By: Date: Type: Tamper esistant Tamper esistant eceptacles FEATUES Designed to coordinate with the unique look of the ASPIE Design System - Available in three distinctive, two-tone color combinations hite Satin, Desert Sand and Silver ranite. Features our correct wiring/trip indicator light technology, making certain that every installation is properly wired to provide optimal protection. Indicator light provides quick visual reference of a tripped or end of life condition. eset button lock-out function protects from miswired line-load connections and FCI circuitry damage. 2-Pole, 3-ire 15A, 125V/AC 20A, 125V/AC ASPIE Collection & ecessed eceptacles Trip threshold (5ma+/-1ma) and response time (0.025 sec.) meet Class A requirements. Ultrasonically welded backbody. 20 amp feed-through rating allows full protection of downstream receptacles when wired from load side. round screw backwiring clamp for fast, secure termination. Maximum wiring flexibility is provided with 8 separate backwiring holes that accept up to #10 A stranded or solid wire. Longer, wider bridged strap provides 40% more contact area with wallboard, virtually eliminating floating installations. ASPIE eceptacles & FCI 9566T (106.43mm) (33.0mm) (33.0mm) 1.20" (30.5mm) 3.81" (96.8mm) 3.81" (96.8mm) 15A 125V 5-15 ASPIE Duplex eceptacle 9505T A, DS, S, S ASPIE Single eceptacle 9507T A, DS, S, S ASPIE Duplex FCI 9566T A, DS, S, S 20A 125V 5-20 ASPIE Duplex eceptacle 9510T A, DS, S, S ASPIE Single eceptacle 9508T A, DS, S, S ASPIE Duplex FCI 9569T A, DS, S, S (83.31mm) 9508T.85" (21.59mm) esidential rade, ecessed 15A 125V 5-15 ecessed Single eceptacle T775 ecessed Duplex eceptacle T780 For ordering, include Cat. No. followed by the color code: A (Alpine hite), DS (Desert Sand), S (Silver ranite), (hite), S (hite Satin) NAFTA Compliant TESTIN & CODE COMPLIANCE culus Listed to UL498, file nos. E60120 (9569T), E15058 (all others): Listed to UL498, file no. E cul Certified to CSA C22.2, no. 42. NOM/ANSI Certified. elated Products MATEIAL CHAACTEISTICS Environmental: Flammability meets UL94 requirements; 9566T, 9569T, 9505T, 9507T, 9508T, 9510T, T775, T780, V2 rated; Temperature ating: 9510T: -20ºC to 60ºC (-4 F to 140 F); 9505T, 9507T, 9508T: -20ºC to 70ºC (-4 F to 158 F); T775, T780: -20ºC to 70ºC (-4 F to 158 F); 9566T, 9569T: -35ºC to 66ºC (-31 F to F). 4.48" (113.8mm) T " (69.1mm) 0.93" (23.6mm) 2" (50.8mm) For more information about Cooper iring Device's eatherproof covers and boxes, use the Q code above or visit: For more information about Cooper iring Device's complete ASPIE Collection, use the Q code above or visit: 7
8 Download a 2D barcode reader application to your smart phone to visit us online: Cooper iring Devices United States 203 Cooper Circle Peachtree City, A P: F: Canada 5925 McLaughlin oad Mississauga, Ontario, L5 1B8 P: F: custserv@cooperwiringdevices.com cwdmarketing@cooperindustries.com Cooper iring Devices, Aspire and eatherbox are valuable trademarks of Cooper Industries in the U.S. and other countries. You are not permitted to use the Cooper Trademarks without the prior written consent of Cooper Industries Cooper Industries, plc. Mexico Carr. Tlalnepantla Cuautitlan Km 17.8 s/n Col. Villa Jardin esq. Cerrada 8 de Mayo Cuautitlan, Mexico CP P: F: Your Authorized Cooper iring Devices Distributor is: Cooper Industries, plc. 600 Travis, Ste Houston, TX P: TTBOC-11
Specification Grade Straight Blade Receptacles. Quality solutions that provide reliable connectivity in all applications
Specification Grade Straight Blade eceptacles Quality solutions that provide reliable connectivity in all applications Arrow Hart Straight Blade eceptacles Arrow Hart deep roots of more than a century
More informationArrow Hart hospital grade self-test GFCI receptacles
Description 2-pole, 3-wire grounding 15A, 125V/AC; 20A, 125V/AC NEMA 5-15, 5-20 Design features Performs periodic self-tests to ensure integrity of GFCI protection. Meets and exceeds 10 ka short circuit
More informationAfci TR Duplex 20A 125V La. Features amperage rating 20. Dimensions and Weight Width 3.3. Long Description
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 TRAFCI20LA Afci TR Duplex 20A 125V La Eaton Wiring Devices Catalog Number Manufacturer Weight per unit Product Category
More informationArrow Hart specification grade GFCI receptacles
Technical Data Description 2-pole, 3-wire grounding 15A, 125V/AC 20A, 125V/AC SGF20 TAMPER RESISTANT Design features Performs periodic self-tests to ensure integrity of GFCI protection Visual trip indicator
More informationAfci TR Duplex 20A 125V Iv. Features amperage rating. Dimensions and Weight. Descriptions
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 TRAFCI20V Afci TR Duplex 20A 125V Iv Eaton Wiring Devices Catalog Number Manufacturer Description Weight per unit Product
More informationAF/GF dual-purpose receptacles
Eaton Wiring Devices OBC AF/GF dual-purpose receptacles AF/GF dual-purpose receptacles Arc fault and ground fault protection in one device In Stock July 2016! Eaton Wiring Devices OBC AF/GF dual-purpose
More informationGfci Self Test Duplex 20A 125V WH
SGF20W Gfci Self Test Duplex 20A 125V WH Eaton Wiring Devices Catalog Number Manufacturer Description Weight per unit Product Category Descriptions Description Long Description Product Type special features
More informationResidential Occupancy & Vacancy Sensors
Eaton s Wiring Devices Occupancy & vacancy sensors Residential Occupancy & Vacancy Sensors Simple and affordable solutions for energy savings and convenience Eaton s residential occupancy & vacancy sensors
More informationAspire LED, CFL & Incandescent Dimmer
Incandescent Dimmer Description Single Pole & 3-Way 300W Dimmable LED, Compact Fluorescent (CFL) 600W Incandescent/Halogen 9573 Design features Preset feature allows user to return to previous light when
More informationIntroducing a revolutionary new line of 15 and 20 amp devices engineered for fast and easy installation
Sold by: http://www.twacomm.com Toll Free: (877) 389-0000 Commercial / Industrial Introducing a revolutionary new line of 15 and 20 amp devices engineered for fast and easy installation Introduction lev-lok
More informationMORE PROTECTION. MORE FUNCTIONALITY. IN MORE ENVIRONMENTS.
PASS & SEYMOUR SELF-TEST GFCI RECEPTACLES REINVENTING SAFETY ALL AROUND MORE PROTECTION. MORE FUNCTIONALITY. IN MORE ENVIRONMENTS. 2 SAFETY IS OUR CODE When we invented the first GFCI receptacle, our goal
More informationAHAC-DT MicroSet dual tech low/line voltage ceiling sensors
s Ceiling sensors description The dual technology sensor s combination of ultrasonic and passive infrared technologies offers the most complete sensing equipment available today. MicroSet self-adjusting
More informationArrow Hart. Universal Dimmers and Sensors. Eaton s Arrow Hart. Reliable lighting control for commercial installations
Eaton s Arrow Hart Commercial lighting controls Eaton s Arrow Hart Universal Dimmers and Sensors Reliable lighting control for commercial installations Arrow Hart Eaton s sensors and dimmers are cost -effective
More informationArrow Hart. Universal Dimmers and Sensors. Eaton s Arrow Hart. Reliable lighting control for commercial installations
Eaton s Arrow Hart Commercial lighting controls Eaton s Arrow Hart Universal Dimmers and Sensors Reliable lighting control for commercial installations Arrow Hart Eaton s s and dimmers are cost -effective
More informationReceptacles. Wiring Devices Receptacles. Receptacle Families. Receptacle Colors. Standard Grade. Academy Series Outlets. Decorator Standard Grade
STION Wiring evices Receptacles Receptacles From decorator and standard styles to Tamper Resistant receptacles, our broad line covers virtually any need throughout a house. ll of our receptacles are designed
More informationThe most complete line of proven safety solutions.
P&S Tamper-Resistant Receptacles The most complete line of proven safety solutions. Meets National Electrical Code Requirements designed to be better. P&S Tamper-Resistant Receptacles the full line to
More informationTAMPER & WEATHER RESISTANT RECEPTACLES
TAMPER & WEATER RESISTANT RECEPTACLES Now ENERLITES Tamper-Resistant Receptacles keep children safe! Our protective shutter system prevents kids from inserting hairpins, keys, paperclips, and other common
More informationToggle AL series dimmer
Technical Data Description Single-Pole & 3-Way 300W Dimmable LED, Dimmable Compact Fluorescent (CFL) 600W/VA Incandescent (INC)/Halogen (HAL), Dimmable Fluorescent (FLR), Magnetic Low-Voltage (MLV), Electronic
More informationSmart AL series dimmers
Technical Data Description Single-Pole & Multi-Location 300W Dimmable LED, Dimmable Compact Fluorescent (CFL) 600W/VA Incandescent (INC)/Halogen (HAL), Dimmable Fluorescent (FLR), Magnetic Low-Voltage
More informationSlide AL series dimmer
Technical Data Description Single-pole & 3-way 300W Dimmable LED, Dimmable Compact Fluorescent (CFL) 600W/VA Incandescent (INC)/Halogen (HAL), Dimmable Fluorescent (FLR), Magnetic Low-Voltage (MLV), Electronic
More informationToggle AL series dimmer
Technical Data Description Single-pole & 3-way 300W Dimmable LED, Dimmable Compact Fluorescent (CFL) 600W/VA Incandescent (INC)/Halogen (HAL), Dimmable Fluorescent (FLR), Magnetic Low-Voltage (MLV), Electronic
More informationAspire smart AL dimmer
Technical Data Aspire smart AL dimmer Description Single-pole & multi-location 300W Dimmable LED/CFL 600W Incandescent/halogen, magnetic low-voltage, electronic low-voltage, fluorescent 9540-N 9542 Design
More informationSAL06PBK 300/600W 120V Dimmer. Features. Dimensions and Weight. Long Description
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 SAL06PBK 300/600W 120V Dimmer Eaton Wiring Devices Catalog Number Manufacturer Description Weight per unit Product Category
More informationSmart AL series dimmers
Technical Data Description Single pole & 3-Way 300W Dimmable LED/CFL 600 INC, HAL, FLR, MLV, ELV 120V/AC AAL06 ARD Design features Preset feature allows user to return to previous light setting when turning
More information3099-2E. Technical Information
3099-2E Brand Features Leviton s line of temporary power solutions now includes industrial grade portable outlet boxes with cover plates and weather resistant flip lids. For applications ranging from industrial
More informationDecorator AL series dimmer
Technical Data Description Single pole & 3-Way 300W Dimmable LED/CFL 600W INC,HAL,FLR, MLV, ELV DAL06P Design features Preset feature allows user to return to previous light level when turning lights ON
More informationRecp HG Dup 20A 125V 2P3W STR B/Swire WH
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 AllenWatson@elliottelectric.com AH8300W Recp HG Dup 20A 125V 2P3W STR B/Swire WH Cooper Wiring Devices Catalog Number
More informationRecp Duplex 20A 125V 2P3W STR Swire WH
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 CR20W Recp Duplex 20A 125V 2P3W STR Swire WH Eaton Wiring Devices Catalog Number Manufacturer Description Weight per unit
More information100A / 200A. Maximum Heating Load: Enclosure Type: NEMA 4
Contactor Panel with GFEP Data Sheet GENERAL PRODUCT INFORMATION Simplify your snowmelt installation with ProLine Radiant contactor panels with built in GFEP. These rugged panels feature built-in ground
More informationType MTS Miniature Test Switches
Type MTS Miniature Test Switches Compact and versatile Front- and back-connected styles Safe, durable, rugged and reliable Recognized by CUL & UL Class IE qualified per IEEE Standard 33-1974 DESCRIPTION
More informationThe Safer Living Collection
The Safer Living Collection T H E S A F E R L I V I N G C O L L E C T I O N Improving Home Safety and Your Bottom Line We ve been leading advocates of electrical safety for over 100 years. Advancements
More informationStellar. A Product of its Surroundings.
Stellar Stellar A Product of its Surroundings. The Stellar family of ambient fluorescent lighting, including the new squared Stellar Q series, features an open-baffle design to facilitate efficient direct-indirect
More informationB. Shop Drawings: List of legends and description of materials and process used for premarking wall plates.
SECTION 262726 - WIRING DEVICES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,
More informationSECTION (16140) - WIRING DEVICES
SECTION 26 27 26 (16140) - WIRING DEVICES PART 1 GENERAL 1.01 SUMMARY A. Section Includes: 1. Receptacles, Connectors, Switches, and Finish Plates. B. Related Sections: 1. Section 00 31 13.43 (00370) -
More informationGen Purpose Wiring Devices - Gen Purpose Switches
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 AH1202W 2P 15A 120/277V TGL SW Eaton Wiring Devices Catalog Number AH1202W Manufacturer Eaton Wiring Devices Description
More informationLighting and Fan Speed Controls
Lighting and Fan Speed ontrols Smart Dimmer System -1 Decorator Touch Dimmers -2 Decorator Slide Dimmers -3 Rotary Dimmers -4 Rotary Dimmers Replacement Knobs -5 Toggle Dimmers -6 Architectural Dimmers
More informationPower Blocks - Splicer/Distribution
POWER BLOCKS Power Blocks - Splicer/Distribution Electrical 60-2280 amps 600 volts AC/DC (UL) Flexible stranded wire compliant Multiple wire rating - refer to data sheets for details Listed products provide
More informationAH8219HG Conn HG 15A 125V 2P3W STR BW
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 AH8219HG Conn HG 15A 125V 2P3W STR BW Catalog Number AH8219HG Manufacturer Description Conn HG 15A 125V 2P3W STR BW 4737657
More informationJob No A. Submit the following equipment, materials and products, including all fittings and accessories:
SECTION 262726 - WIRING DEVICES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and other Division 01 Specification
More informationIntroducing Hermaphroditic Blade and Receptacle Connector
Introducing Hermaphroditic Blade and Receptacle Connector Wire-to-Board, Board-to-Board and Dust Cover Hermaphroditic Blade and Receptacle Connector : Wire-to-Board KEY FEATURES Available in 2, 4, and
More informationHeavy Industrial/Marine MaxGard
6 Heavy Industrial/Marine MaxGard MaxGard Interconnection Systems Overview Defined Any application where electrical connections need protection from water and/or dust ingress to contacts or wiring compartment
More informationSwitch Toggle DP 20A 120/277V Swire Iv
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 CS220V Switch Toggle DP 20A 120/277V Swire Iv Eaton Wiring Devices Catalog Number Manufacturer Description Weight per
More informationSECTION ISOLATED POWER SYSTEMS
PART 1 - GENERAL 1.1 DESCRIPTION SECTION 26 20 11 ISOLATED POWER SYSTEMS SPEC WRITER NOTE: Delete between //---// if not applicable to project. Also, delete any other item or paragraph not applicable to
More informationLeviton Combination Switch And Tamper Resistant Outlet Wiring Diagram
Leviton Combination Switch And Tamper Resistant Outlet Wiring Diagram Leviton SmartLockPro 15 Amp Tamper-Resistant Combination GFCI Duplex Outlet and Switch - White-R02-X7299-00W - The Home Depot. From
More informationA. This Section provides requirements and specifications for wiring devices, wiring device accessories, and wiring device assemblies including:
SECTION 262726 - WIRING DEVICES PART 1 - GENERAL 1.1 SUMMARY A. This Section provides requirements and specifications for wiring devices, wiring device accessories, and wiring device assemblies including:
More informationDelayed Egress System DORMA EMDE
Delayed Egress System DORMA EMDE Delayed Egress System EMDE-1000 Series Delayed Egress Systems Designed to meet NFPA Life Safety Code 101, Special Locking Arrangements, these U.L. listed, self-contained
More informationPANELBOARDS & BUILDING DISTRIBUTION
262416 PANELBOARDS & BUILDING DISTRIBUTION PART 1 GENERAL 1.01 SUMMARY A. Section Includes: 1. Distribution panelboards 2. Power panelboards B. Related Sections: 1.02 POLICY 1. CU Standard 260500, Basic
More informationCHAPTER 20 SERVICE EQUIPMENT
SERVICE EQUIPMENT CHAPTER 20 SERVICE EQUIPMENT Service equipment includes service cabinets and the equipment and materials necessary for installation. 20.1 Signal Service Cabinet For MnDOT traffic control
More informationExtra Heavy Duty Industrial & Hospital Grade GFCI Receptacles
Extra Heavy Duty Industrial & Hospital Grade GFCI Receptacles and Weather Resistant GFR5362SGI 10kA Short Circuit Current Rating Limits improper access to energized contacts Exclusive patented tamper-resistant
More informationHALO. 2700K nominal. 3000K nominal. RA4 LED Very Wide Flood (VWFL)
DESCRIPTION The Halo RA4 ED Adjustable Gimbal series are retrofit ED Modules for 4 aperture recessed downlights. The RA4 gimbals feature adjustment of 35-degree tilt and up to 360-degree rotation. In addition
More informationA. Furnish and install wiring devices and plates as specified herein and as shown on the Drawings.
DIVISION 26 ELECTRICAL SECTION 26 27 26 PART 1 GENERAL 1.01 DESCRIPTION A. Furnish and install wiring devices and plates as specified herein and as shown on the Drawings. B. Specialty switches and outlets
More informationArcLine Recessed LED luminaire
ArcLine Recessed LED luminaire 1' x 4' 2' x 2' 2' x 4' ArcLine Recessed LED luminaire ArcLine is a premium grade specification lensed troffer series. This innovative, high quality luminaire is dedicated
More informationEver evolving energy code requirements and the large demand for energy
Ever evolving energy code requirements and the large demand for energy saving products have made lighting control sensors a must-have for building owners and managers. Hubbell Control Solutions introduces
More informationCable Limiters Increase System Reliability Decrease Downtime
Limiters Increase System Reliability Decrease Downtime Increase system reliability and versatility with Ferraz Shawmut Limiters. Limiters are designed for the protection of low voltage distribution networks,
More informationRA406930NFLWH 4" Led Adj Gimbal 30K 120V Narrow FLD
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 RA406930NFH 4" ed Adj Gimbal 30K 120V Narrow FD Eaton ighting Catalog Number Manufacturer Description eight per unit Product
More informationSURE-LITES. LEM PathLinx Series. LED Emergency Lighting
SURE-LITES LEM PathLinx Series LED Emergency Lighting LED Emergency Lighting Advanced technology provides for up to four remote LED heads Aesthetic, compact, thin profile design blends into commercial
More informationWallbox Lighting Controls Project Name:
ACCELL Features Electro-mechanical push pad for ON/OFF operation with separate DIM/BRIGHT bar Preset feature allows user to return to previous light setting when turning lights ON Master/Accessory units
More informationMaxGard. Interconnection Systems. Durability. Performance. Safety
8Russellstoll Pin and Sleeve Power Connectors Safety Different power supply ratings can t mix: 24 single-rate device polarizations ensure exact voltage, frequency and phase differentiation Safe connections:
More informationRZI06, RZE06, RZI10, RZM10
Vizia-RF Scene Capable s Vizia-RF Scene Capable s are part of Leviton s Vizia-RF Wireless Home Control System. The system combines the popular Vizia family lighting devices with Z-Wave awardwinning RF-based
More informationInstallation and Operation Manual
Electronic Thermostats with Ground Fault Equipment Protection Model SST 2 40 Freeze Protection Thermostat P/N 22744 MANUAL We Manage Heat Model SST 2 175 Fixed Set Point Thermostat P/N 23708 Installation
More informationRLN Recessed LED luminaire
RLN Recessed LED luminaire 1' x 4' 2' x 2' 2' x 4' RLN Recessed LED luminaire RLN blends modern styling with an innovative optical design. This contemporary, high quality luminaire provides superior visual
More information1NT SERIES Fixed Temperature Thermostats
1NT SERIES Fixed Thermostats Key Features WORLD CLASS PERFORMANCE The 1NT has been designed to be applied as a safety device for use in many HVAC and appliance products. Using patented Klixon technology
More informationStep Lighting. For indoor and outdoor, stair and pathway applications. Juno Lighting Group Juno Step Lighting 1
Step Lighting For indoor and outdoor, stair and pathway applications Juno Lighting Group Juno Step Lighting 1 Lighting your way Table of Contents Mini LED Step Lights p. 4-9 Performance LED Step Lights
More informationProject. Comments. Prepared by. - EZ Hang feature facilitates fast - Prorated 5-year battery warranty - Overload / Short Circuit - NEC/OSHA
DESCRIPTION The Sure-Lites emergency series (SEL) is a UL 924 code compliant LED solution that provides from 25 feet to 60 feet of emergency egress coverage for a minimum of 90 minutes during a power outage.
More informationCustom Pump Controls. The Custom Controls Solution Provider. A New Generation. Complete Management. Page 2
The Custom Controls Solution Provider Hydromatic has a reputation for providing dependable submersible pumps for wastewater lift stations and has continually raised the bar for quality products and customer
More informationCIRCUITPRO Self Test Ground Fault Receptacles
IRUITPRO Self Test Technology 1st introduced by ryant over 10 years ago! self test monitoring now required in 2015 UL 943 GFI Safety Tamper- Resistant Hospital Grade ombo Switch/GFI udible ryant Self Test
More informationMaestro Occupancy Sensing Switch
Maestro Sensing Switch Lutron Maestro Sensing switches with occupancy and vacancy sensors are lighting controls with passive infrared sensors that automatically control the lights in an area. These sensors
More informationLED Control Solutions. Smooth, flicker-free dimming for every application
LED Control Solutions Smooth, flicker-free dimming for every application Table of Contents Dimmers 3 C L dimmers 9 Reverse phase dimmers 11 Phase select dimmers 13 Dimmer capabilities 15 0 10 V dimmers
More informationAUTOGUARD Hubbell Self Test Ground Fault Circuit Interrupters. More innovation. More protection. More safety.
AUTOGUARD Hubbell Self Test Ground Fault Circuit Interrupters. More innovation. More protection. More safety. The GFCI that Tests Itself! You may forget, but Hubbell AutoGuard GFCI won't. Nothing delivers
More informationMALIBU FM /2" N-Brushed Nickel. Nickel **ESTIMATED FROM LED SOURCE
INDOOR LIGHTING Available in LED & Incandescent Direct/Indirect Light Ceiling Mount Only 3 Mounting Options UL Listed for Damp Locations SURFACE MOUNT MALIBU FM300 13 3/4" OPTIONAL MOUNTING KITS (sold
More informationLED-CFL Dimmers. LED Dimmer D4-D5. Slide Dimmers D-1
IMMERS ENERLITES dimmers allow users to adjust lights to desired lighting levels in residences, offices, schools, hotels, stores, restaurants, other types of facilities. ENERLITES offers a variety of dimming
More informationNORTH BAY PARRY SOUND HEALTH
NORTH BAY PARRY SOUND HEALTH LEGEND: (ARCHITECTURAL) DA-01 X-RAY APPROVAL PLAN DA-02 DETAILS DA-03 AIR TECHNIQUES AS30 AIR COMPRESSOR D AIR TECHNIQUES VS50H VACUUM UNIT 11'-3" [3.43] EXAM.1 EXAM.2 9'-7"
More informationPackaged Terminal Air Conditioner (PTAC)
Air Conditioner / Heat Pump / Backup Electric Heater 16" 42" Depth More Easy-To-Use Features Comfort Control Design Simple controls allow guests to customize their settings, while quiet, uniform air movement
More informationPART GENERAL 1.01 SECTION INCLUDES
Specification Number: 26 24 16.06 Product Name: Emergency Lighting Control NQ Circuit Panelboards: 240 Vac, 48 Vdc Maximum SECTION 26 24 16.06 Emergency Lighting Control NQ Circuit Panelboards: 240 Vac,
More informationASCO Series 185 Power Transfer Switches
ASCO Series 185 Power Transfer Switches 24-hour protection no matter when trouble strikes ASCO Series 185 POWER TRANSFER SWITCHES An Automatic Transfer Switch helps prevent... Your business or home from
More informationPackaged Terminal Air Conditioner (PTAC)
Packaged Terminal Air Conditioner (PTAC) Air Conditioner / Heat Pump / Backup Electric Heater 16" 42" Depth 21-3/4" More Easy-To-Use Features Comfort Control Design Simple controls allow guests to customize
More informationCatalog # Project. Comments. Prepared by. Warranty Five year warranty
DESCRIPTION The Converge series by Neo-Ray defines the new standard in ambient lighting by combining the highest degree of minimization with the most advanced optical distribution and control available.
More informationSECTION LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES (600 VOLTS AND BELOW)
SECTION 26 05 21 PART 1 - GENERAL 1.1 DESCRIPTION This section specifies the furnishing, installation, and connection of the low voltage power and lighting wiring. 1.2 RELATED WORK A. Excavation and backfill
More informationSure-Lites. 13" [330mm] 3 1/8" [80mm] 4 3/4" [121mm] Emergency Light w/remote Capacity SEL SERIES
DESCRIPTION The Sure-Lites Emergency Light SEL series is a UL924 code compliant solution designed to run for a minimum of 90 minutes during a outage. Key features of the series include: a nickel cadmium
More informationGreentrol Automation, Inc.
Model GA-100 Technical Manual GreenAlert 100 Series Greentrol Automation, Inc. Installation, Operation and Maintenance Technical Manual GA-100 Document Name: TM_GA-100_R1C TM_GA-100_R1C Part Number: 960--0000
More informationDISTRIBUTOR SELECT COLLECTION. EMERGI-LITE Full range of emergency lighting solutions
COLLECTION EMERGI-LITE Full range of emergency lighting solutions Distributor Select products Popular emergency lighting products are in stock and ready to ship from warehouses across North America for
More informationPackaged Terminal Air Conditioner (PTAC)
Air Conditioner / Electric Heater 16" 42" Depth More Easy-To-Use Features Effortless Temperature Control Frigidaire air conditioners maintain the preset room temperature so the room remains comfortable
More informationGE Industrial Solutions. Residential Electronic Circuit Interrupters
GE Industrial Solutions Residential Electronic Circuit Interrupters Dual Function Circuit Interrupter (DFCI) Provides ground fault and arc fault circuit protection in one unit The 2014 National Electric
More informationDETECT-A-FIRE Heat Detectors
DETECT-A-FIRE Heat Detectors DETECT-A-FIRE thermal detectors are detection and release devices used for fire detection systems to activate alarms and actuate extinguishing systems. This rate compensated
More information0ACDT2000MV Ultasonic/Infared Occ Sensor
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 0ACDT2000MV Ultasonic/Infared Occ Sensor Eaton Lighting Catalog Number 0ACDT2000MV Manufacturer Eaton Lighting Description
More informationSECTION ELECTRICAL GENERAL PROVISIONS
PART 1 GENERAL 1.01 SECTION INCLUDES A. General provisions for Electrical Systems B. Wire and cable for 600 volts and less. C. Wiring connectors. D. Electrical tape. E. Heat shrink tubing. F. Wire pulling
More informationChamp VMV LED Series Luminaires Leading the way in LED technology for industrial and hazardous applications. Now cul Listed!
Enhancing Safety + Productivity Champ VMV LED Series Luminaires Leading the way in LED technology for industrial and hazardous applications Now cul Listed! High-performance, high-brightness Champ VMV LED
More informationSECTION PANELBOARDS Painting Wire and Cable Overcurrent Protective Devices.
SECTION 16470 PANELBOARDS PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 09900 - Painting. 2. 16120 - Wire and Cable. 3. 16475 - Overcurrent Protective Devices. 1.02 SYSTEM DESCRIPTION A. Performance
More informationAlbeo TM LED Luminaire Accessory (Emergency Battery Backup Module)
E Lighting Installation uide Albeo TM LED Accessory (Emergency attery ackup Module) EFOE YOU EI ead these instructions completely and carefully. ead and follow appropriate Lumination LED Installation uide
More informationElectricity Unit Notes. Agriculture Mechanics I
Electricity Unit Notes Agriculture Mechanics I Principles of Electricity Electricity is a form of energy that can produce light, heat, magnetism, chemical changes Resistance: tendency of a material to
More informationPipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual
MANUAL Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual Model FPT 130 Single Point Freeze Protection Heat Trace Control Table of Contents SCFP-CO-F130 Overview... 3 Installation...
More informationLUCE 1 TL. specifications: internal. specifications: external. ordering logic. builder. Job/Location:
LUCE 1 TL indoor / damp Job/Location: Contractor: Prepared By: Job Type: Date: The LUCE-1TL thinline emergency ballast is designed to provide emergency illumination to existing or new fluorescent luminaires.
More informationMetroline LED architectural luminaire
Metroline LED architectural luminaire Good design is obvious. Great design is transparent. Joe Sparano, Tweet At the intersection of modern technology and design A city is defined by its pedestrian experience.
More informationThe T6140A,B Remote Bulb Temperature Controller
T640A,B Remote Bulb Temperature Controller The T640A,B Remote Bulb Temperature Controller is used as a unit mount temperature controller in electric heat, fan coil, room air conditioner applications, cold
More informationPOINT HELIDECK LIGHTS PRL-EX-LSM LED v4 CLASS I, DIVISION 2 & ZONE 2
Compliances: ETL Listed Class I, Division 2, Groups A B C D, T6 at -40 deg C to +55 deg C ETL Listed Class I, Zone 2, Groups IIA, IIB+H2, IIC T6 at -40 deg C to +55 deg C ETL Listed to UL 844 & UL 1598
More informationSingle Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual
We manage heat MANUAL Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual 1850 N Sheridan Street South Bend, Indiana 46628 (574) 233-1202 or (800) 234-4239
More informationXP Series Non-Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof
NEC/ Applications Protection and control of electrical apparatus and circuits in hazardous environments, either indoor or outdoor. Designed for Class I areas where flammable gases or vapors are present
More informationMaestro Occupancy sensing switch
Maestro Occupancy sensing switch To power the sensing circuit, occupancy sensing switches require a small flow of current when the load is in the OFF state. This can be accomplished by connecting the power
More informationBasics Series Surface Mount LED Fixtures. Affordable and easy-to-install, 4" and 6" fixtures. It s a. Snap
Basics Series Surface Mount LED Fixtures Affordable and easy-to-install, 4" and 6" fixtures It s a Snap Easiest to install LED fixture ever... and so affordable! There s never been an easier to install
More informationSpecial Provision No. 682S27 June This Special Provision refers to the following standards, specifications or publications:
CONTROLLER CABINETS, POLE MOUNTED - Item No. Special Provision No. 682S27 June 2017 1. SCOPE This Special Provision covers the requirements for the installation of pole mounted controller cabinets and
More information