SPECTRA 1728, 1738 CHEAT SHEET:

Size: px
Start display at page:

Download "SPECTRA 1728, 1738 CHEAT SHEET:"

Transcription

1 SPECTRA 1728, 1738 CHEAT SHEET: ZONE MAPPING: Device connected To which input? NO ATZ WITH ATZ CONTROL PANEL INPUT 1= ZONE 1 ZONE 1 & 6 INPUT 2= ZONE 2 ZONE 2 & 7 INPUT 3= ZONE 3 ZONE 3 & 8 INPUT 4= ZONE 4 ZONE 4 & 9 INPUT 5= ZONE 5 ZONE 5 & 10 INPUT 6= N/A N/A INPUT 7= N/A N/A KEYPAD ZONE 1= ZONE 6 ZONE 11 ZONE 2= ZONE 7 ZONE 12 ATZ = Zone Doubling The Zone doubling feature allows you to install two devices per hardwired input terminal. Each detection device will have its own zone, display its own zone status on the keypad and send separate alarm codes for each zone. Each zone is differentiated by a different resistor value. EXPANSION INPUT 1= ZONE 8 ZONE 13 INPUT 2= ZONE 9 ZONE 14 INPUT 3= ZONE 10 ZONE 15 INPUT 4= ZONE 11 ZONE 16 INPUT 5= ZONE 12 N/A INPUT 6= ZONE 13 N/A INPUT 7= ZONE 14 N/A INPUT 8= ZONE 15 N/A *A location is referred to as a section. *Value or data is referred to as an option. 1

2 HOW ENTER PROGRAM MODE: PRESS THE ENTER KEY ENTER THE INSTALLER CODE (DEFAULT: 0000). ENTER LIGHT WILL FLASH (PROMPTING A SECTION NUMBER BE ENTERED) ENTER 3 DIGIT SECTION. ENTER LIGHT WILL TURN ON SOLID (INDICATING THAT YOU ARE AT A SECTION NUMBER) ENTER DATA AS REQUIRED * PRESS CLEAR ONCE STEP BACK ENTER LIGHT FLASHING HOW PROGRAM ZONES: GET IN PROG. MODE: ENTER SECTION NUMBER (e.g : 001 = Zone 1) STEP 5: STEP 6: ENTER ONE DIGIT FROM THE ZONE DEFINITION TABLE (i.e. instant, follow {handover}, entry) ENTER ONE DIGIT FROM THE PARTITION ASSIGNMENT TABLE (you are assigning that zone to an area/partition) SELECT ONE OR MORE OPTIONS FROM THE ZONE OPTIONS TABLE (This table is a toggle ON/OFF feature.) I.e. if key 2 is on = Bypassable zone, this means it is enabled. If you want to disable it, press key 2, and the led will turn off. This disables that option. PRESS ENTER SAVE *PANEL AUMATICALLY JUMPS NEXT ZONE ADDRESS IN ZONE PROGRAMMING SYSTEM TIMERS: SECTION: [069] ENTRY DELAY 1 *45 SECS SECTION: [071] EXIT DELAY 1 *30 SECS SECTION: [078] NUMBER OF RINGS *DISABLED SECTION: [087] AU TEST REPORT DAYS *DISABLED SECTION: [110] AU TEST REPORT TIME *DISABLED *Bold is default setting HOW PROGRAM ACCESS CODES: PRESS ENTER KEY IN MASTER CODE KEY IN 3 DIGIT USER SECTION SECTION: [302] MASTER CODE 1 SECTION: [303] MASTER CODE 2 SECTION: [304] USER CODE 4 SECTION: [348] USER CODE 48 (Refer to page 18 of programming guide) STEP 5: KEY IN NEW CODE, ENTER LIGHT WILL FLASH, PROMPTING A NEW USER LOCATION END, PRESS CLEAR. PROGRAM IN USER CODE OPTIONS SECTION 281: INSTALLER CODE 2

3 LEARNING IN WIRELESS DEVICES: PIR s & TRANSMITTERS (Omnia or 1759EX protocol) GET IN PROGRAMMING MODE KEY IN 3 DIGIT SECTION NUMBER (Refer to page 24 of programming Guide) ENTER IN SERIAL NUMBER OF PIR OR TRANSMITTER SECTION: [601] SERIAL NUMBER = EXPANSION INPUT 1 SECTION: [602] SERIAL NUMBER = EXPANSION INPUT 2 SECTION: [608] SERIAL NUMBER = EXPANSION INPUT 8 (The serial number is found on the PCB of the device.) ENABLE ZONE THAT RELATES THAT EXPANSION INPUT (Refer to zone mapping table) LEARNING IN WIRELESS DEVICES: REMOTE CONTROLS ASSIGN REMOTE CONTROL 3 DIGIT USER SECTION SECTION: [701] _/_/_ REMOTE CONTROL 1 SECTION: [702] _/_/_ REMOTE CONTROL 2 SECTION: [708] _/_/_ REMOTE CONTROL 8 (Refer to page 26 of programming guide) ASSIGN FEATURE OPTIONS YOUR BUTNS SECTION: [711] 1 / 5 / _ / _ / _ / _ / _ / _ / Button: A B C D A+B C+D A+C B+D FOR REMOTE CONTROL 1 SECTION: [712] REMOTE CONTROL No 2 OPTIONS SECTION: [718] REMOTE CONTROL No 8 OPTIONS Programmed here is : (example only) Button A is to operate as Regular Arm = 1 Button B is to operate as Disarm = 5. Then press enter once you have added the options you require. PROGRAM IN THE REMOTES SECTION: [731] FOR REMOTE CONTROL 1. PRESS BUTN A TWICE (a confirmation beep will be heard). SECTION: [732] FOR REMOTE CONTROL 2 SECTION: [738] FOR REMOTE CONTROL 8 ZONE EXPANSION MODULES: (ZX-4 OR ZX-8) ENTER PROGRAM MODE SECTION: [650] OPTION 1 IS ENABLE END OF LINE SECTION: [651] OPTION 1 IS ENABLE EXPANSION INPUT 1 OPTION 2 IS ENABLE EXPANSION INPUT 2 OPTION 8 IS ENABLE EXPANSION INPUT 8 (Option 650 & 651 is a toggle ON/OFF section) ENABLE EXPANSION INPUT ZONES (Refer to zone mapping table) 3

4 PERSONAL DIAL PROGRAMMING: SECTION: [081] Select max dialing attempts = 2 SECTION: [135] Option 3and 4 and should be ON SECTION: [136] Option 3 should be OFF SECTION: [137] Option 3+4 should be ON only SECTION: [138] Option 1 to 8 should be OFF SECTION: [140] 6 / 6 REPORTING FORMATS TEL1 TEL2 SECTION: [143] 1 / 2 / 3 / 4 PARTITION ACCOUNT NUMBER 1 SECTION: [144] / / / PARTITION ACCOUNT NUMBER 2 REPORTING CODES: SECTION: [151] 0 / 2 / 5 / 1 / 2 / 3 / 4 / 5 / 6 /TBL/TBL/ 3 / 2 / 1 /TBL/ 3 / 2 / 1 /TBL CENTRAL STATION TELEPHONE NUMBER 1 (if less than 32 press [ENTER] to accept) SECTION: [152] 0 / 2 / 5 / 1 / 2 / 3 / 4 / 5 / 6 /TBL/TBL/ 3 / 2 / 1 /TBL/ 3 / 2 / 1 /TBL CENTRAL STATION TELEPHONE NUMBER 2 (if less than 32 press [ENTER] to accept) (When this dials the phone number, the recipient will hear a series of tones (3 2 1) followed by a pause, then there will be a rapid series of DTMF tones as the panel sends the pager message) SECTION: [187] Alarm Reporting codes (zones 1-4) SECTION: [190] Alarm Reporting codes (zones 13-16) STROBE PROGRAMMING: SECTION: [066] PGM1 Timer 0 / 0 / 0 Seconds Event Group # Sub-Group # Partition # SECTION: [120] 0 / 2 0 / 4 9 / 9 SECTION: [121] 0 / 2 0 / 9 9 / 9 STROBE FLASHES ON ARM/DISARM VIA REMOTES : SECTION: [067] PGM2 Timer 0 / 0 / 5 Seconds Event Group # Sub-Group # Partition # SECTION: [122] 0 / 6 9 / 9 9 / 9 SECTION: [123] must be left empty 4

5 STROBE CONNECTION FOR PGM s: NOTE: Place a link between PGM1 & PGM2 if the arm/disarm strobe flash function is required. Place Link between PGM 1& PGM 2 across here. PGM 1 (-) PGM 2 (-) AUX + 5

CHEAT SHEET: SPECTRA V2.1

CHEAT SHEET: SPECTRA V2.1 CHEAT SHEET: SPECTRA V2.1 Zone mapping Device connected To which input? NO ATZ WITH ATZ CONTROL PANEL INPUT 1= ZONE 1 ZONE 1 & 6 INPUT 2= ZONE 2 ZONE 2 & 7 INPUT 3= ZONE 3 ZONE 3 & 8 INPUT 4= ZONE 4 ZONE

More information

1728EX, 1728, 1738EX AND 1738 SYSTEM PROGRAMMING GUIDE

1728EX, 1728, 1738EX AND 1738 SYSTEM PROGRAMMING GUIDE DEFAULT INSTALLER CODE 0000 / 000000 (see section [281] on page 17) DEFAULT SYSTEM MASTER CODE 1234 / 123456 (see section [301] on page 17) HOW DO I ENTER PROGRAMMING MODE? STEP 1: Press [ENTE R] STEP

More information

PROGRAMMING GUIDE SPECTRA CONTROL PANELS V , 1725EX, 1728 AND 1728EX 1755, 1755EX, 1758, AND 1758EX

PROGRAMMING GUIDE SPECTRA CONTROL PANELS V , 1725EX, 1728 AND 1728EX 1755, 1755EX, 1758, AND 1758EX PROGRAMMING GUIDE SPECTRA CONTROL PANELS V1.2 1725, 1725EX, 1728 AND 1728EX 1755, 1755EX, 1758, AND 1758EX TABLE OF CONTENTS HOW DO I PROGRAM THE SYSTEM?... 4 Single Digit Data Entry Method (Hexadecimal

More information

Digiplex System V2.14 / V2.2ACC. Control Panel Programming Guide

Digiplex System V2.14 / V2.2ACC. Control Panel Programming Guide Digiplex System V2.14 / V2.2ACC Control Panel Programming Guide Table of Contents Getting Started...2 What Do I Do First?...2 How Do I Program the Control Panel?...2 Single Digit Entry Method...2 Multiple

More information

MG5000 V2.4 MG5050 V2.4 SP5500 V2.4 SP6000 V2.4 SP7000 V2.4. Programming Guide

MG5000 V2.4 MG5050 V2.4 SP5500 V2.4 SP6000 V2.4 SP7000 V2.4. Programming Guide MG5000 V2.4 MG5050 V2.4 SP5500 V2.4 SP6000 V2.4 SP7000 V2.4 Programming Guide We hope this product performs to your complete satisfaction. Should you have any questions or comments, please visit www.paradox.com

More information

All-In-One Wireless Security System V3.2 Programming Guide. Model # MG6130 / MG6160

All-In-One Wireless Security System V3.2 Programming Guide. Model # MG6130 / MG6160 All-In-One Wireless Security System V3.2 Programming Guide Model # MG6130 / MG6160 We hope this product performs to your complete satisfaction. Should you have any questions or comments, please visit www.paradox.com

More information

DSC PowerSeries NEO Quick Start Guide

DSC PowerSeries NEO Quick Start Guide DSC PowerSeries NEO Quick Start Guide WE DO NOT RECOMMEND BEING IN ANY PROGRAMMING SECTION THAT IS NOT IN THIS GUIDE UNLESS YOU FULLY UNDERSTAND THE FUNCTION OF THAT SECTION. Doing so may cause problems

More information

USER CODES. User Codes (1-6 digits) Access Levels + Access Levels. Time Control Address Address Address Address User 1 (Master)

USER CODES. User Codes (1-6 digits) Access Levels + Access Levels. Time Control Address Address Address Address User 1 (Master) User Codes (1-6 digits) Access Levels Access Levels + Time Control User 1 (Master) 1 1 2 3 25 49 73 0 User 2 2 26 50 74 0 User 3 3 27 51 75 0 User 4 4 28 52 76 0 User 5 5 29 53 77 0 User 6 6 30 54 78 0

More information

Sentry 4 Zone Alarm Panel User Manual

Sentry 4 Zone Alarm Panel User Manual TM TM Sentry 4 Zone Alarm Panel User Manual PLEASE NOTE: A 16Vac / 16VA Transformer MUST be used with this product. Contents 1. Introduction. 2. Programming a Remote. 3. Deleting all Remote s. 4. The siren

More information

CC880/LP880, SC8016. Operators Guide Solution-16, Solution-16 Safecom

CC880/LP880, SC8016. Operators Guide Solution-16, Solution-16 Safecom CC880/LP880, SC8016 EN Operators Guide Solution-16, Solution-16 Safecom CC880/LP880, SC8016 Operators Guide EN 2 Copyright Notice Unless otherwise indicated, this publication is the copyright of Bosch

More information

Alarm Control Panel WIC-16Z4P WIC-5Z2P. Installation & Operation User Manual

Alarm Control Panel WIC-16Z4P WIC-5Z2P. Installation & Operation User Manual WIC-16Z4P WIC-5Z2P Installation & Operation User Manual Page : 1/34 INDEX # Function Page 1 Abort Current Communication and Clear Reporting Queue (*59) 13 2 Abort Current Communications (*59) 10 3 Account

More information

System Programming Guide

System Programming Guide & System Programming Guide Software Versions 4.4 (728ULT) and 4.1 (738ULT) Installer Code (Default - 728 Ultra: 282828; 738 Ultra: 383838) Full access to programming, except user access codes (PINs). No

More information

Elite 16D Version 16 Zone Controller Arrowhead Alarm Products Ltd. Operating Guide. Proudly Designed and Manufactured in New Zealand

Elite 16D Version 16 Zone Controller Arrowhead Alarm Products Ltd. Operating Guide. Proudly Designed and Manufactured in New Zealand 6 Elite 16D Version 16 Zone Controller Arrowhead Alarm Products Ltd Operating Guide 1 Proudly Designed and Manufactured in New Zealand CONTENTS Page No. INTRODUCTION 3 About your Alarm 3 OPERATING YOUR

More information

3 User s settings. 3.3 Internal clock setting

3 User s settings. 3.3 Internal clock setting 2.9 Subsystem arming In a large building a sub control panel can be enrolled to the JA-63. The subsystem reports all alarms and failures to the main system. The installer can program if the systems will

More information

ICP-CC488 ICP-CC488 EN. Control Panel. User s Guide

ICP-CC488 ICP-CC488 EN. Control Panel. User s Guide ICP-CC488 EN User s Guide ICP-CC488 Control Panel ICP-CC488 User's Guide Notices EN 2 Copyright Notice Unless otherwise indicated, this publication is the copyright of Bosch Security Systems, Inc. ( Bosch

More information

MG Partition 64-Zone Wireless Console with GPRS/GSM Version 1.6. Section Programming Guide

MG Partition 64-Zone Wireless Console with GPRS/GSM Version 1.6. Section Programming Guide MG6250 2-Partition 64-Zone Wireless Console with GPRS/GSM Version.6 Section Programming Guide Things You Need to Know About this Programming Guide The MG6250 All-in-one Wireless Console can be programmed

More information

Voice Board. Installation and Programming Guide. Runner 4/8,PowerWave 4/8/16 &, Elite64. Add-on Board For Storing Recorded Voice Messages

Voice Board. Installation and Programming Guide. Runner 4/8,PowerWave 4/8/16 &, Elite64. Add-on Board For Storing Recorded Voice Messages ELECTRONIC ENGINEERING LTD. Voice Board Runner 4/8,PowerWave 4/8/16 &, Elite64 Add-on Board For Storing Recorded Voice Messages And listen-in. Installation and Programming Guide. P/N 7101372 Rev. C V.K

More information

DL-250 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

DL-250 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL DL-250 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL TABLE OF CONTENTS 1. GENERAL DESCRIPTION...P.2 2. STANDARD AND OPTIONAL PARTS LIST...P.2 3. FEATURE DEFINITIONS...P.3 4. TERMINAL DRAWING AND

More information

Solution Ultima Series Operators Manual ISSUE 1.00

Solution Ultima Series Operators Manual ISSUE 1.00 Solution Ultima Series Operators Manual ISSUE 1.00 Solution Ultima Series Operators Manual Copyright 1998 by, SYDNEY, AUSTRALIA Document Part Number MA488O DOCUMENT ISSUE 1.00 Printed 16 February 1999

More information

WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER

WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER BAT.LOW AC WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER THE SYSTEM THAT CALLS YOU! Our WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER is designed to allow you to create your own security system.

More information

JA-63 Profi User manual

JA-63 Profi User manual JA-63 Profi User manual Contents: 1 Limited warranty... 2 2 Indicators... 3 3 Controlling the system... 4 3.1 Arming... 5 3.2 Disarming... 6 3.3 Panic Alarm... 6 3.4 To stop ALARM... 6 3.5 Home arming...

More information

SOFTWARE VERSION 2.20 CONTROL PANEL RESET: Installer lock must be unlocked. (Address 255: enter any value other than 147)

SOFTWARE VERSION 2.20 CONTROL PANEL RESET: Installer lock must be unlocked. (Address 255: enter any value other than 147) -961112-0003 SOFTWARE VERSI 2.20 CTROL PANEL RESET: Installer lock must be unlocked. ( 255: enter any value other than 147) Power down reset (1) Remove battery and AC to power down the unit. (4) Wait 3

More information

Solution Ultima 862 Operators Manual ISSUE 1.10

Solution Ultima 862 Operators Manual ISSUE 1.10 Solution Ultima 862 Operators Manual ISSUE 1.10 Solution Ultima 862 Operators Manual Copyright 2001 by, SYDNEY, AUSTRALIA Document Part Number MA486O DOCUMENT ISSUE 1.10 Printed 24 April 2001 This documentation

More information

CC488. Quick Reference Guide Solution Ultima 880

CC488. Quick Reference Guide Solution Ultima 880 CC488 EN Quick Reference Guide Solution Ultima 880 CC488 Quick Reference Guide Notices EN 2 Copyright Notice Unless otherwise indicated, this publication is the copyright of Bosch Security Systems Pty

More information

MG5000 MG5050 SP5500 SP6000 SP7000. User Guide

MG5000 MG5050 SP5500 SP6000 SP7000. User Guide MG5000 MG5050 SP5500 SP6000 SP7000 User Guide We hope this product performs to your complete satisfaction. Should you have any questions or comments, please visit www.paradox.com and send us your comments.

More information

Thank you for choosing Ideal Security s Home Security System with Telephone Dialer.

Thank you for choosing Ideal Security s Home Security System with Telephone Dialer. SK618 WIRELESS ALARM SYSTEM WITH AUTO DIALER OWNER'S MANUAL Thank you for choosing Ideal Security s Home Security System with Telephone Dialer. If at any time during your installation you have any questions

More information

ICP-CC408 ICP-CC408 EN. Control Panel. User s Guide

ICP-CC408 ICP-CC408 EN. Control Panel. User s Guide ICP-CC408 EN User s Guide ICP-CC408 Control Panel ICP-CC408 User's Guide Notices EN 2 Copyright Notice Unless otherwise indicated, this publication is the copyright of Bosch Security Systems, Inc, ( Bosch

More information

CC408. Quick Reference Guide Solution 880

CC408. Quick Reference Guide Solution 880 CC408 EN Quick Reference Guide Solution 880 CC408 Quick Reference Guide Notices EN 2 Copyright Notice Unless otherwise indicated, this publication is the copyright of Bosch Security Systems Pty Ltd ( Bosch

More information

Elite 64 Version 64 Zone Controller Arrowhead Alarm Products Ltd. Operating Guide. Proudly Designed and Manufactured in New Zealand

Elite 64 Version 64 Zone Controller Arrowhead Alarm Products Ltd. Operating Guide. Proudly Designed and Manufactured in New Zealand 2 Elite 64 Version 64 Zone Controller Arrowhead Alarm Products Ltd Operating Guide Proudly Designed and Manufactured in New Zealand 1 CONTENTS Page No. INTRODUCTION 3 About your Alarm 3 OPERATING YOUR

More information

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING -961212-0004 SOFTWARE VERSI 3.10 CTROL PANEL RESET: Installer lock must be unlocked. (Address 058: enter any value other than 147) Power down reset (1) Remove battery and AC to power down the unit. (2)

More information

Understanding the Code Pad lights...4. Code Pad tones...5. Fully arming the system On MODE...6. Fully arming the system - Quick Arm MODE...

Understanding the Code Pad lights...4. Code Pad tones...5. Fully arming the system On MODE...6. Fully arming the system - Quick Arm MODE... TABLE OF CONTENTS...Glossary of terms...2...code Pad Diagram...3 Understanding the Code Pad lights...4 Code Pad tones...5 Fully arming the system On MODE...6 Fully arming the system - Quick Arm MODE...6

More information

Quick Programmer s Manual

Quick Programmer s Manual Version 2.604 (31/03/05) p1 Quick Programmer s Manual 2005. Inner Range Pty. Ltd. Part Number: 630048V2 p2 Version 2.604 (31/03/05) TABLE OF CONTENTS. 1. PROGRAMMING FLOWCHART. The following flowchart

More information

ALARM CONTROL PANEL AND DIALLER USER S MANUAL. Revision 4.5 A$15.00 INC GST. Ness D8 control panel User s manual

ALARM CONTROL PANEL AND DIALLER USER S MANUAL. Revision 4.5 A$15.00 INC GST. Ness D8 control panel User s manual D8 ALARM CONTROL PANEL AND DIALLER USER S MANUAL A$15.00 INC GST Ness D8 control panel User s manual Revision 4.5 Ness Security Products Pty Ltd Quality Endorsed Company ISO9001 LIC.No. QEC2074 NSW Head

More information

HILLS Series LED Code Pad User Manual

HILLS Series LED Code Pad User Manual HILLS Series LED Code Pad User Manual Not all features may be available on your system Check with your installer to find out which features are programmed Page 2 TABLE OF CONTENTS Code Pad Diagrams...2

More information

Version 1.03 January-2002 USER S MANUAL

Version 1.03 January-2002 USER S MANUAL Version 1.03 January-2002 1 USER S MANUAL 2 Version 1.03 January-2002 System Details CUSTOMER:...... PHONE:... FAX:... INSTALLED BY:...... PHONE:... FAX:... MAINTENANCE & SERVICE:...... PHONE:... FAX:...

More information

User s Guide. SUB-MA7240O-0001.OG.Solution doc. Created: 6/05/03. Last Updated: 23/09/03. MA7240AO-0001 Version 1.0

User s Guide. SUB-MA7240O-0001.OG.Solution doc. Created: 6/05/03. Last Updated: 23/09/03. MA7240AO-0001 Version 1.0 User s Guide SUB-MA7240O-0001.OG.Solution40-111.doc Created: 6/05/03 Last Updated: 23/09/03 MA7240AO-0001 Version 1.0 2 Table Of Contents User List...6 Quick Reference..7 Features...7 Keypad User's Guide...8

More information

SK642 THE TELEPHONE DIALER REQUIRES A LAND TELEPHONE LINE TO MAKE OUTGOING CALLS AND ELECTRICITY.

SK642 THE TELEPHONE DIALER REQUIRES A LAND TELEPHONE LINE TO MAKE OUTGOING CALLS AND ELECTRICITY. SK642 WIRELESS WATER ALARM SYSTEM WITH AUTO DIALER OWNER'S MANUAL AND SET UP INSTRUCTIONS. Thank you for choosing Ideal Security s Wireless Water Alarm with Telephone Dialer. Please read through complete

More information

Installation Manual Premier 412/816/832. Issue 10

Installation Manual Premier 412/816/832. Issue 10 Installation Manual Premier // Issue 0 Premier // Installation Manual 5. Operating the System Introduction Before attempting to operate the alarm system ensure you have familiarised yourself with all the

More information

Contents. Glossary

Contents. Glossary Contents Glossary ------------------------------------------------------------------------------------------------------ 6 1. Introduction to the IDS 1632 -------------------------------------------------------------

More information

VAP304 PRO INSTALLATION & OPERATION MANUAL

VAP304 PRO INSTALLATION & OPERATION MANUAL VAP304 PRO INSTALLATION & OPERATION MANUAL Panic Fire Duress Program Bypass Report Chime Test Memory B A D C Program Chime Panic Duress Exit Fire Report Bypass Memory Test Reset Password Exit Reset Password

More information

SOFTWARE VERSION 2.20 CONTROL PANEL RESET:

SOFTWARE VERSION 2.20 CONTROL PANEL RESET: -961112-0002 SOFTWARE VERSI 2.20 CTROL PANEL RESET: Installer lock must be unlocked. ( 255: enter any value other than 147) Power down reset (1) Remove battery and AC to power down the unit. (4) Wait 3

More information

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING -961212-0004 SOFTWARE VERSION 3.10 CONTROL PANEL RESET: Installer lock must be unlocked. ( 058: enter any value other than 147) Power down reset (1) Remove battery and AC to power down the unit. (2) Connect

More information

EVO192 v3.0 Fire and Burglary What s New

EVO192 v3.0 Fire and Burglary What s New EVO192 v3.0 Fire and Burglary What s New Compatibility: EVO192 v3.0 TM50 v1.31 K641 v2.41 Overview: CP-01 Compliancy Wiring Diagram The following sections/options have been added to the EVO192 panel. They

More information

0$(6752 0$(6752. Programming Guide. 6 and 10 Zone Alarm Control Panel ,1752'8&7,21 +(;$ 352*5$00,1* 675($0/,1(' 6(&7,21 352*5$00,1* FIGURE 1 FIGURE 2

0$(6752 0$(6752. Programming Guide. 6 and 10 Zone Alarm Control Panel ,1752'8&7,21 +(;$ 352*5$00,1* 675($0/,1(' 6(&7,21 352*5$00,1* FIGURE 1 FIGURE 2 0$(6752 0$(6752 6 and 10 Zone Alarm Control Panel Programming Guide,1752'8&7,21 The Maestro-600 and Maestro-1000 alarm control panels enable reduced number of programming steps. End-users can access most

More information

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING 48ESEP-01 SOFTWARE VERSION 3.10 CONTROL PANEL RESET: Installer lock must be unlocked. (Address 058: enter any value other than 147) Power down reset (1) Remove battery and AC to power down the unit. (2)

More information

XT30/XT50 PROGRAMMING PART 2. Slide 1. Slide 2. Slide 3. Objectives. XT30/XT50 Basic Training Programming- Part 2. Bell Options

XT30/XT50 PROGRAMMING PART 2. Slide 1. Slide 2. Slide 3. Objectives. XT30/XT50 Basic Training Programming- Part 2. Bell Options Slide 1 XT30/XT50 Basic Training Programming- Part 2 Slide 2 Objectives After completing this course you will: 1) Understand how to prepare the panel for programming and how to access the built-in programmer.

More information

Control/Communicator Installation Manual

Control/Communicator Installation Manual DAS NETWORX NX-12 Control/Communicator Installation Manual General Description...2 Ordering Information...2 Option Definitions...3 Programming the LED Code Pads...5 Programming the NX-12...9 Types of Programming

More information

8-zone Expansion Module

8-zone Expansion Module 8-zone Expansion Module APR3-ZX8 SECTION [001] : General Options Option OFF ON [1] Tamper Recognition ON = Input 8 (Z8) becomes tamper input = Default setting Disabled Enabled [2] PGM Deactivation After

More information

Digiplex Control Panel (DGP-848) - V4.0

Digiplex Control Panel (DGP-848) - V4.0 Digiplex Control Panel (DGP-848) - V4.0 DGP-848 Reference and Installation Manual TABLE OF CONTENTS INTRODUCTION... 4 1.0 1.1 Features... 4 1.2 Specifications... 4 INSTALLATION... 5 2.0 2.1 Location &

More information

PowerWave-16. Users Operating and Programming Guide Version P/N Rev. B N.A July 2002

PowerWave-16. Users Operating and Programming Guide Version P/N Rev. B N.A July 2002 ELECTRONIC ENGINEERING LTD. PowerWave-16 16 zone Control panel Communicator Users Operating and Programming Guide Version 6.20 P/N 7121240 Rev. B N.A July 2002 Contents Introduction...4 Meet the Crow Alarm

More information

DSC Power832/PC5010 Wiring the MN01-4G Cellular Communicator and Programming the Panel

DSC Power832/PC5010 Wiring the MN01-4G Cellular Communicator and Programming the Panel DSC Power832/PC5010 Wiring the MN01-4G Cellular Communicator and Programming the Panel CAUTION: It is advised that an experienced alarm installer programs the panel as further programming may be required

More information

System Introduction. Digital Communicator Specifications: Supports all Major Formats including SIA and Contact ID Event Initiated Personal Paging

System Introduction. Digital Communicator Specifications: Supports all Major Formats including SIA and Contact ID Event Initiated Personal Paging 1.1 Specifications System Introduction S E C T I O N 1 Control Panel Specifications Flexible Zone Configuration: 8 Fully Programmable Zones 38 Access Codes: 32 User, 1 System Master, 2 Partition Master,

More information

System Introduction. 1.1 Specifications S E C T I O N 1

System Introduction. 1.1 Specifications S E C T I O N 1 System Introduction S E C T I O N 1 1.1 Specifications Control Panel Specifications Flexible Zone Configuration: 8 Fully Programmable Zones 37 Access Codes: 32 User, 1 System Master, 2 Partition Master

More information

PowerMaxComplete User Guide

PowerMaxComplete User Guide PowerMaxComplete User Guide Table of Contents Compatibility of this Manual...2 Quick Guide To Primary Alarm Control Operations...2 Contact list form...2 Luminous Indicator Signals...2 Siren Signals...3

More information

User Guide MG5000 MG5050 SP5500 SP6000 SP7000

User Guide MG5000 MG5050 SP5500 SP6000 SP7000 MG5000 MG5050 SP5500 SP6000 SP7000 User Guide We hope this product performs to your complete satisfaction. Should you have any questions or comments, please visit www.paradox.com and send us your comments.

More information

Solution 6+6 Wireless - AE Installation Manual ISSUE 1.10

Solution 6+6 Wireless - AE Installation Manual ISSUE 1.10 Solution 6+6 Wireless - AE Installation Manual ISSUE 1.10 MA660I Solution 6+6 This page has been included for you to cut out and insert into the spine of the folder Wireless AE Installation Manual ISSUE

More information

LCD and 16-Zone LED Keypads. User s Manual

LCD and 16-Zone LED Keypads.   User s Manual LCD and 16-Zone LED Keypads 1689 1641 16-Zone LED Keypad LCD Keypad User s Manual TABLE OF CONTENTS 1.0 INTRODUCTION...3 2.0 BASIC OPERATION...4 2.1 Keypad Indicator Lights... 4 2.2 Visual Feedback...

More information

User Guide PowerMaster-10/ PowerMaster-30 Fully supervised wireless alarm control system

User Guide PowerMaster-10/ PowerMaster-30 Fully supervised wireless alarm control system Fully pervised ireless alarm control tem Fully pervised ireless alarm control rol tem Fully pervised User Guide PowerMaster-10/ PowerMaster-30 Fully supervised wireless alarm control system PowerMaster-10

More information

QUICK USER MANUAL. Alarm Control Panel. The full user manual and other manuals are available on

QUICK USER MANUAL. Alarm Control Panel. The full user manual and other manuals are available on Alarm Control Panel Firmware Version 1.09 QUICK USER MANUAL The full user manual and other manuals are available on www.satel.eu versa_ip_us_en 11/17 SATEL sp. z o.o. ul. Budowlanych 66 80-298 Gdańsk POLAND

More information

Always Armed, Never Disarmed User Guide

Always Armed, Never Disarmed User Guide 32-Zone Security System Always Armed, Never Disarmed User Guide User Settings For security reasons, write only the user s name and not their user code. 4-Digit Codes 6-Digit Codes User # and Name Byp*

More information

Thank you for choosing Ideal Security s Home Security System with Telephone Dialer.

Thank you for choosing Ideal Security s Home Security System with Telephone Dialer. SK618 WIRELESS ALARM SYSTEM WITH AUTO DIALER OWNER'S MANUAL Thank you for choosing Ideal Security s Home Security System with Telephone Dialer. If at any time during your installation you have any questions

More information

User Guide PowerMaxComplete

User Guide PowerMaxComplete wireless em Fully ss alarm lly superm control ervised ntrol sysd wireless em Fully ss alarm lly superm control ervised User Guide PowerMaxComplete Fully supervised wireless alarm control system PowerMaxComplete

More information

System Introduction. 1.1 PC5015 Specifications S E C T I O N 1

System Introduction. 1.1 PC5015 Specifications S E C T I O N 1 1.1 PC5015 Specifications System Introduction S E C T I O N 1 Flexible Zone Configuration: 8 Fully Programmable Zones 38 Access Codes: 32 User, 1 System Master, 2 Partition Master, 2 Duress and 1 maintenance

More information

Elite S Version 8-16 Zone Controller Arrowhead Alarm Products Ltd. Operating Guide. Proudly Designed and Manufactured in New Zealand

Elite S Version 8-16 Zone Controller Arrowhead Alarm Products Ltd. Operating Guide. Proudly Designed and Manufactured in New Zealand 9 Elite S Version 8-16 Zone Controller Arrowhead Alarm Products Ltd Operating Guide Proudly Designed and Manufactured in New Zealand 1 CONTENTS Page No. INTRODUCTION About your Alarm 3 3 OPERATING YOUR

More information

Installation Manual IMPORTANT. PC5020 Version 3.1 DLS-3 v1.3 and higher

Installation Manual IMPORTANT. PC5020 Version 3.1 DLS-3 v1.3 and higher IMPORTANT WARNING:This manual contains information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer. The entire manual should be

More information

Training Manual Multi-Language with Wireless

Training Manual Multi-Language with Wireless Training Manual Multi-Language with Wireless Installer Training Firmware Version 2.3 X16 Stock Code: 860-1-473-X16 X64 Stock Code: 860-1-864-XS 2 Contents IDS X Series Training V2.3 Contents Contents 3

More information

System Introduction. 1.1 Specifications

System Introduction. 1.1 Specifications System Introduction S E C T I O N 1 1.1 Specifications Downloading Software Support PC585 uses DLS-1 v6.5 and up. Flexible Zone Configuration Four fully programmable zones; system expandable to eight zones

More information

ADEMCO VISTA-12A ADEMCO VISTA-12E Security Systems

ADEMCO VISTA-12A ADEMCO VISTA-12E Security Systems ADEMCO VISTA-12A ADEMCO VISTA-12E Security Systems User Guide K10021-1V1 10/05 Rev. A SYSTEM COMPATIBILITY NOTICE Your Honeywell security system is designed for use with devices manufactured or approved

More information

ADEMCO VISTA-48 SERIES

ADEMCO VISTA-48 SERIES ADEMCO VISTA-48 SERIES Security Systems User Guide This control complies with EN50131-3:2009 and conforms to UL requirements. K0750ENV2 5/11 Rev. A Table of Contents Burglary System Overview...3 Basic

More information

D3D Wi-Fi GSM Smart Alarm System -User Manual

D3D Wi-Fi GSM Smart Alarm System -User Manual D3D Wi-Fi GSM Smart Alarm System -User Manual D3D Wi-Fi / GSM Smart Alarm system (Model : D10). Please read all instructions carefully & follow steps for easy home installation. 1 P a g e D3D Wi-Fi / GSM

More information

10-Zone Spectra LED Keypads

10-Zone Spectra LED Keypads 10-Zone Spectra LED Keypads User s Guide TABLE OF CONTENTS Introduction... 5 Basic Operation... 6 Auditory Feedback... 6 Keypad Indicator Lights... 8 Zone Display... 8 Alarm Memory Display... 8 Trouble

More information

ITI Caretaker Basic Commands

ITI Caretaker Basic Commands ITI Caretaker Basic Commands System can be accessed by telephone or wireless keypad Zones - Up to 30 Wireless or 24 Hardwired Battery - 12 volt 1.9 amp rechargeable Lead-Acid inside main panel, only found

More information

Solution 6+6 Wireless On/Off Installation Manual ISSUE 1.20

Solution 6+6 Wireless On/Off Installation Manual ISSUE 1.20 Solution 6+6 Wireless On/Off Installation Manual ISSUE 1.20 MA670I This page has been included for you to cut out and insert into the spine of the folder Solution 6+6 Wireless On/Off Installation Manual

More information

M2M Services Ltd. RControl Alarm - Installer Manual V 1.0

M2M Services Ltd. RControl Alarm - Installer Manual V 1.0 M2M Services Ltd. RControl Alarm - Installer Manual V 1.0 Content Content... 2 Wiring the power supply module... 3 Wiring a siren... 3 SMARTEnroll self-learning zones... 3 Wireless keyfobs... 3 Supported

More information

Solution 844 Operators Manual ISSUE 1.10

Solution 844 Operators Manual ISSUE 1.10 Solution 844 Operators Manual ISSUE 1.10 Solution 844 Operators Manual Copyright 2001 by, SYDNEY, AUSTRALIA Document Part Number MA406O DOCUMENT ISSUE 1.10 Printed 24 April 2001 This documentation is provided

More information

All-In-One Wireless Security System V1.0. Model # MG Programming Guide

All-In-One Wireless Security System V1.0. Model # MG Programming Guide All-In-One Wireless Security System V1.0 Model # MG-6060 Programming Guide Things You Should Know... 4 About This Programming Guide... 4 Conventions... 4 Installer Code (Default: 0000 / 000000)... 4 Maintenance

More information

9,67$36HULHV 6HFXULW\6\VWHPV 8VHU*XLGH K5309-1V1 7/02

9,67$36HULHV 6HFXULW\6\VWHPV 8VHU*XLGH K5309-1V1 7/02 9,67$3366HULHV 9,67$36HULHV 6HFXULW\6\VWHPV 8VHU*XLGH K5309-1V1 7/02 IMPORTANT! PROPER INTRUSION PROTECTION For proper intrusion coverage, sensors should be located at every possible point of entry to

More information

Summit 3208GLD USER MANUAL. Electronics Line

Summit 3208GLD USER MANUAL. Electronics Line Summit 3208GLD USER MANUAL Electronics Line Table of Contents 1: Introduction... 2 2: Overview... 3 3: Keypad Functions... 4 3.1: Keypads... 4 3.2: 3108 LCD Keypad Layout... 4 4: Basic System Operation...

More information

Training Manual with Bi-directional Wireless

Training Manual with Bi-directional Wireless Training Manual with Bi-directional Wireless Installer Training Firmware Version 2.7x X16 Stock Code: 860-1-473-X16 X64 Stock Code: 860-1-864-XS 2 IDS X-Series Training v2.7 Contents Contents 3 X-Series

More information

User Manual (LS-GSM-006)

User Manual (LS-GSM-006) GSM Home/Business Alarm System User Manual (LS-GSM-006) Profile For a better understanding of this product, please read this user manual thoroughly before using it. - 1 - Catalogue: Function Introduction

More information

BENTEL SECURITY srl reserves the right to modify the technical specifications of this product without prior notice.

BENTEL SECURITY srl reserves the right to modify the technical specifications of this product without prior notice. BENTEL SECURITY srl reserves the right to modify the technical specifications of this product without prior notice. via Florida - Z.I. Valtesino - 63013 GROTTAMMARE (AP) - ITALY USER MANUAL: Digital communicator

More information

X64 Wireless Training

X64 Wireless Training X64 Wireless Training IDS Contents 1 Contents Features 3 Wireless Hardware 4 IDS & Duevi integration PCB 5 LED operation 5 Wireless Device Hardware setup 6 Location 260 7 LED Keypad Instructions 7 Adding

More information

DL150 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

DL150 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL DL150 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL TABLE OF CONTENTS 1. GENERAL DESCRIPTION... 2 2. STANDARD AND OPTIONAL PARTS LIST... 2 3. FEATURE DEFINITIONS... 3 4. TERMINAL DRAWING AND SPECIAL

More information

MEDI-CALL UNIT INSTALLATION MANUAL. Medi-Call V2.0 - V2.7 Installation Manual

MEDI-CALL UNIT INSTALLATION MANUAL. Medi-Call V2.0 - V2.7 Installation Manual MEDI-CALL UNIT INSTALLATION MANUAL Medi-Call V2.0 - V2.7 Installation Manual Copyright SmartLink International Pty Ltd February 2006 475 Nepean Highway, Brighton VIC 3186 Australia Telephone: +61 3 9596

More information

ADEMCO VISTA-12A ADEMCO VISTA-12E

ADEMCO VISTA-12A ADEMCO VISTA-12E ADEMCO VISTA-12A ADEMCO VISTA-12E Security Systems User Guide K10021-1 9/04 Rev. A Table of Contents Burglary System Features... 3 Basic Features... 3 Exit/Entry Delays... 3 Before Arming (Ready [ ] Key)...

More information

NetworX Series. NX-8 Commercial Fire Panel Installation and Startup

NetworX Series. NX-8 Commercial Fire Panel Installation and Startup NetworX Series NX-8 Commercial Fire Panel Installation and Startup 2004 GE Security All rights reserved. Printed in the United States of America. These instructions do not purport to cover all details

More information

POWERMAX PRO USER GUIDE Quick Guide To Primary Alarm Control Operations...2 Contact list form...2 Luminous Indicator Signals...2 Siren Signals...3 Useful Hints For PowerMax Pro Users...3 1. Introduction...4

More information

User s Information Guide R2A

User s Information Guide R2A Pi HSC505 Home Security Controller User s Information Guide R2A Page 1 of 15 of its development program. 1This document and product are copyrighted and all rights are reserved. Introduction Convention

More information

32-Zone Wireless Transceiver Control Panel MG5000. User s Guide

32-Zone Wireless Transceiver Control Panel MG5000. User s Guide 32-Zone Wireless Transceiver Control Panel MG5000 MG32LED MG32LRF MG10LEDH MG10LEDV User s Guide We hope this product performs to your complete satisfaction. Should you have any questions or comments,

More information

Table of Contents. All-In-One Wireless Security System V1.3. Programming Guide. Model # MG-6060 / MG-6030

Table of Contents. All-In-One Wireless Security System V1.3. Programming Guide. Model # MG-6060 / MG-6030 All-In-One Wireless Security System V1.3 Programming Guide Model # MG-6060 / MG-6030 Table of Contents Things You Should Know... 2 About This Programming Guide... 2 Conventions... 2 Installer Code (Default:

More information

&RPPHUFLDO%XUJODU\ 3DUWLWLRQHG6HFXULW\6\VWHP ZLWK6FKHGXOLQJ

&RPPHUFLDO%XUJODU\ 3DUWLWLRQHG6HFXULW\6\VWHP ZLWK6FKHGXOLQJ READY ARMED READY 1 OFF 7 INSTANT READY 2 AWAY 8 CODE 6BYPASS 9 CHIME 9,67$% &RPPHUFLDO%XUJODU\ 3DUWLWLRQHG6HFXULW\6\VWHP ZLWK6FKHGXOLQJ 8VHU*XLGH ARMED READY 1 OFF 2 AWAY 3 STAY 4 MAX 5 TEST 6 BYPASS

More information

Watchguard WGAP864 User Manual

Watchguard WGAP864 User Manual Watchguard WGAP864 User Manual v1.0 Issued September 2016 1 2 Table of Contents Glossary... 5 1. Introduction to your Watchguard WGAP864... 6 2. Before Operating your Alarm System... 6 3. Understanding

More information

Alarm Control Panel WIC-16Z4P WIC-5Z2P. User Instructions

Alarm Control Panel WIC-16Z4P WIC-5Z2P. User Instructions WIC-16Z4P WIC-5Z2P User Instructions Page : 2/14 INDEX # Function Page 1 Add a New User Code 11 2 Arm or Disarm All Areas or Disarm Selected Areas (Partitioned System) 8 3 Arming the System (Away Mode)

More information

USER GUIDE. Contact Visonic for further information:

USER GUIDE. Contact Visonic for further information: 2014 Tyco Security Products Ltd. All rights reserved. PowerMaxPro Partition II English User Guide D-303978 USER GUIDE Contact Visonic for further information: Email: info@visonic.com www.visonic.com POWERMAXPRO

More information

$'(0&2 9,67$ 3DUWLWLRQHG 6HFXULW\ 6\VWHP 8VHU *XLGH N7003V3 5/04 Rev A

$'(0&2 9,67$ 3DUWLWLRQHG 6HFXULW\ 6\VWHP 8VHU *XLGH N7003V3 5/04 Rev A $'(0&29,67$ 3DUWLWLRQHG6HFXULW\6\VWHP 8VHU*XLGH N7003V3 5/04 Rev A 2 TABLE OF CONTENTS SYSTEM OVERVIEW...5 General...5 A Partitioned System...5 Zones...5 Fire Protection...6 Burglary Protection...6 Alarms...6

More information

Series. NX-4-EUR Control Panel. Installation manual

Series. NX-4-EUR Control Panel. Installation manual g GE Security NetworX TM Series NX-4-EUR Control Panel Installation manual CONTENTS CONTENTS...2 GENERAL INFORMATION...4 ORDERING INFORMATION...4 FEATURE DEFINITIONS...5 PROGRAMMING THE NX-4 KEYPADS...12

More information

VISTA-20PMT. Security. Systems. User s Guide. Monitronics

VISTA-20PMT. Security. Systems. User s Guide. Monitronics VISTA-15PMT VISTA-20PMT Security Systems User s Guide Monitronics R I N T E R N A T I O N A L, I N C. K5309-1MTV2 7/04 Rev. A Reference: MTV15P, MTV20P IMPORTANT! PROPER INTRUSION PROTECTION For proper

More information

Ness D8x / D16x ALARM CONTROL PANEL USER'S MANUAL. Revision 5.0 A$15.00

Ness D8x / D16x ALARM CONTROL PANEL USER'S MANUAL. Revision 5.0 A$15.00 Ness D8x / D16x ALARM CONTROL PANEL USER'S MANUAL Revision 5.0 A$15.00 www.ness.com.au Australia s largest designer and manufacturer of high quality security products Head Office: Ness Security Products

More information

MOBILE CALL GSM Alarm System User s Manual

MOBILE CALL GSM Alarm System User s Manual MOBILE CALL GSM Alarm System User s Manual Profile For a better understanding of this product, please read this user manual thoroughly before using it. Contents Function Introduction (3) Alarm Host Diagram

More information

Control Panel ICP-SOL2-P/ICP-SOL3-P. en User's Guide

Control Panel ICP-SOL2-P/ICP-SOL3-P. en User's Guide Control Panel ICP-SOL2-P/ICP-SOL3-P en User's Guide Control Panel Table of Contents en 3 Table of contents 1 Introduction 5 2 Specifications 6 3 Codepad Introduction 7 3.1 Codepad 7 3.2 Quick Codepad

More information