HELKAMA. Optical Fibre Cables
|
|
- Avice Stevenson
- 5 years ago
- Views:
Transcription
1 1
2 Contents Optical fibres and their characteristics Cable constructions Cable tests Installation, jointing and terminating Manufacturing (pictures) 2
3 Multimode Fibre (GK) Attenuation and Bandwidth Fibre cross section Refractive index profile Transmitted light pulse Propagation of light in fibre Received light pulse Core Parabolic index profile Diameter 62.5 µm ± 3 µm Non-circularity 6 % Concentricity error 3 µm Cladding Diameter 125 µm ± 2 µm Non-circularity 2 % 3 Attenuation Wavelength 850 nm: 3.5 db/km Wavelength 1310 nm: 1.0 db/km Bandwidth Wavelength 850 nm: 200 MHz km Wavelength 1310 nm: 500 MHz km
4 Single-mode Fibre (SM) Attenuation and Dispersion Fibre cross section Refractive index profile Transmitted light pulse Propagation of light in fibre Received light pulse Core Mode field diameter (1310 nm): 9.3 ± 0.5 µm Concentricity error 1.0 µm Cladding Diameter 125 µm ± 2 µm Non-circularity 2 % Attenuation Wavelength 1310 nm: 0.40 db/km Wavelength 1550 nm: 0.25 db/km Chromatic dispersion Wavelength 1310 nm: 3.5 ps/(nm km) Wavelength 1550 nm: 18 ps/(nm km) 4
5 Attenuation Attenuation, db/km Water-peak 850 nm 1310 nm 1550 nm Wavelength, µm 5 Attenuation curve (principle)
6 Typical Characteristics of Multimode Fibres 62,5/125 µm (GK / OM1) 50/125 µm (GI / OM2) 50/125 µm (OM3) Attenuation 850 nm 3,5 db/km 2,7 db/km 2,7 db/km 1310 nm 1,0 db/km 0,8 db/km 0,8 db/km Bandwidth 850 nm 200 MHz km 500 MHz km 1500 MHz km (LED) 1310 nm 500 MHz km 800 MHz km 500 MHz km (LED) 850 nm 2000 MHz km (Laser) Numerical aperture 0,28 0,20 0,20 6
7 Typical Characteristics of Single-mode Fibres Conventional (ITU-T G.652) NZDSF (ITU-T G.655) Attenuation 1310 nm 0,40 db/km nm 0,25 db/km 0,25 db/km Chromatic dispersion 1310 nm 3,5 ps/(nm km) nm 18 ps/(nm km) 0,1...6 ps/(nm km) Cut-off wavelength 1260 nm 7
8 Fibre Spools 8
9 Contents Optical fibres and their characteristics Cable constructions Protection of fibres Core structures Cables for different applications Cable tests Installation, jointing and terminating Manufacturing (pictures) 9
10 Fibre Coatings Loose tube Filling compound Primary coating Tight secondary coating Fibre 2-3 mm 900 µm 250 µm SML/GKL SMT/GKT 10
11 Core Structures Stranded loose tube Slotted core Single tube FZ... FX... FY... 11
12 Fibre Ribbon Primary coating Fibre Ribbon coating 0.4 mm 1.1 mm 12
13 Fibre Ribbons in Slotted Core Structure The most common ribbon cable structure High fibre packing density Easy fibre identification Quick and easy splicing E.g 96 fibre cable with diameter of only 14 mm 13
14 Indoor and Outdoor Cables; Basic Differences Fire properties defined No jelly filling Non-metallic UV-resistant sheath Longitudinally water tight Wide temperature range (-45 C +70 C) Mechanically strong construction 14
15 Indoor / Outdoor Cable Indoor and outdoor applications, Campus and building backbone cabling Non-metallic, no jelly filling, Longitudinally water tight Halogen free, UV-protected sheath SML- and GKL-type fibres Tensile strength N Crush strength 4000 N / 100 mm plate Crush strength N / 25 mm mandrel Impact strength 30 J Standard types 6, 12, 18, 24, 48 SML and 4, 8, 12, 16, 24 GKL 4 SML + 8 GKL, 8 SML + 8 GKL 6 SML + 12 GKL, 12 SML + 12 GKL FXMSU 15
16 Non-metallic Duct Cable Outdoor, duct cable Campus backbone cabling Non-metallic, jelly filled SML- and GKL-type fibres Tensile strength 1750 N Crush strength 7000 N / 100 mm plate Crush strength 1000 N / 25 mm mandrel Impact strength 30 J Standard types 6, 12, 18, 24, 48 SML and 4, 8, 12, 16, 24 GKL 4 SML + 8 GKL, 8 SML + 8 GKL 6 SML + 12 GKL, 12 SML + 12 GKL FXOMU 16
17 Duct Cable Outdoor, duct cable Jelly filled Aluminium laminated sheath SML- and GKL-type fibres Tensile strength 1750 N Crush strength 7000 N / 100 mm plate Crush strength 1000 N / 25 mm mandrel Impact strength 30 J Standard types 6, 12, 18, 24, 48 SML and 4, 8, 12, 16, 24 GKL 4 SML + 8 GKL, 8 SML + 8 GKL 6 SML + 12 GKL, 12 SML + 12 GKL FXOHBMU 17
18 Direct Burial and Duct Cable Duct and directly buried applications Jelly filled Corrugated steel tape (grounding) SML- and GKL-type fibres Tensile strength 2500 N Crush strength 7000 N / 100 mm plate Crush strength 1500 N / 25 mm mandrel Impact strength 50 J Standard types 6, 12, 18, 24, 48 SML and 4, 8, 12, 16, 24 GKL 4 SML + 8 GKL, 8 SML + 8 GKL 6 SML + 12 GKL, 12 SML + 12 GKL FXOVDMU 18
19 Aerial Cable Maximum 80 m span length (25 N/m ice load) Jelly filled Figure-8 construction Suspension strand 7 x 1,57 mm SML- and GKL-type fibres Standard types 6, 12, 18, 24, 48 SML 4 SML + 8 GKL FXOHBMUK 19
20 Underwater Cable Water depth max. 75 m Double armoured Good durability Follows easily the bottom profile Maximum delivery length 7000 m Jelly filled Tensile strength N Standard types 6, 12, 24, 48 SML FXOHBMPPMW 20
21 Installation Cable For protected cable conduits and patch cords in horizontal cabling Halogen free (HF) 900 µm SMT- and GKT-type fibres SM (yellow), GK (green) 1- and 2-fibre constructions 2,0 or 2,9 mm outer diameter Standard types 1 and 2 SMT 1 and 2 GKT FMS 21
22 Installation Cable For cable tray installation and preterminated cables in horizontal cabling Halogen free (HF) 900 µm SMT and GKT-type fibres SM (blue), GK (green) Connectors can be mounted directly to the fibres Tensile strength 1000 N Standard types 2, 4, 6, 8 SMT 2, 4, 6, 8 GKT FXMMS 22
23 Distribution Cable For distribution and workstation cabling Halogen free (HF) 900 µm GKT-type fibres Connectors can be mounted directly to the fibres Tensile strength 700 N Standard types 4, 8, 12, 16, 24 GKT FTMS 23
24 Cable Type Designation (Finnish Standard SFS 5648) Cable type F optical fibre cable Core structure T tight stranded X slotted core Y single tube Z loose stranded Cable elements O jelly filling M plastic sheath P armouring H metal tape B laminated V steel tape D corrugated K suspension strand 24 Application S indoor U outdoor W water Fibre types SM single-mode GK multimode 62,5/125 µm GI multimode 50/125 µm GN multimode 100/140 µm Fibre coating L 250 µm T 900 µm R Ribbon FXOVDMU 1x6 SML + 3x4 GKL
25 Fibre Identification BLUE THREAD SML: BLUE, WHITE, YELLOW, GREEN, GREY, RED RED THREAD GKL: BLUE, WHITE, YELLOW, RED GKL: BLUE, WHITE, YELLOW, RED GKL: BLUE, WHITE, YELLOW, RED RIP CORD 25
26 Contents Optical fibres and their characteristics Cable constructions Cable tests Optical characteristics Mechanical characteristics Water tightness Fire performance Installation, jointing and terminating Manufacturing (pictures) 26
27 Testing Principle The manufacturer carries out all the tests during manufacturing process and before cable delivery as described in the test program Measurements for all cables Attenuation MM-fibres at 850 nm and 1300 nm SM-fibres at 1310 nm and 1550 nm Cable length 27
28 Tensile Strength EN method E1 Cable length under test ( L 50 m ) Pulling machine F = 1 2 W W = weight of 1 km cable length R = 1 m Cable drum Attenuation measurement 28
29 Crush Strength EN method E3 Plate 100 mm + 2 x 5 mm Mandrel 25 mm F F R = 5 mm Cable Cable Base Base 29
30 Impact Strength EN method E4 m Weight Energy W = mgh h Drop 3 times in different places Impact anvil Surface radius = 300 mm m Base Cable Base Cable 30
31 Water Penetration EN method F5 Test duration 24 h 1 m Water Sealing Requirement: No leakage from open end Cable under test 3 m 31
32 Repeated Bending EN method E6 35 times, period 2 s R R = 10d 20d...40 d Cable Pulling load, F = N 32
33 Fire Characteristics Characteristics of cables under fire conditions Amount of acid gases Smoke density Fire safety of installations 33
34 Flame Retardant (Test on Single Vertical Cable) IEC Support Requirement: unburned >50 mm above the upper support after a defined time 475 mm 550 mm 600 mm Least stringent fire performance requirement of the cables Burner 45 Support 34
35 Flame Retardant (Test on Bunched Cables) IEC Cable bunch Categories based on the amount of non-metallic material: A (7 l/m) B (3,5 l/m) C (1,5 l/m) Number of samples in the bunch depend on the category Requirement: Not burned on the length longer than 2,5 m above the burner Burner 0,5 m 75 mm 3, 5 m 35
36 Amount of Halogen Acid Gases IEC and IEC Halogen free means that halogen content is less than 5 mg/g (0,5 %) Halogen free (HF) cable = Halogen content of each cable element is less than 5 mg/g When burned in presence of humidity PVC forms hydrochloric acid (HCl)! HCl 36
37 Smoke Density IEC and IEC Smoke density has a vital implication on rescue and fire extinguish activities Testing is based on light transmission Requirement: e.g. 60 % pass through 37
38 Fire Resistant IEC The cable shall operate for a specified time under fire conditions 75 mm Requirement: Attenuation change (optical fibre cables) 600 mm 38
39 Fire Safety of Installations Application of fire safe indoor cables Outdoor cable is jointed to: fire safe indoor cable immediately when entering the building fire safe indoor/outdoor cable before entering the building Areas where fire risk is high should be avoided Fire barriers in wall openings Sufficient isolation time Important to apply already during installation 39
40 Fire Safe Installation Patch panel HF-riser cable Fire barrier ODF HF-indoor/outdoor cable Outdoor cable 40
41 Contents Optical fibres and their characteristics Cable constructions Cable tests Installation, jointing and terminating Branching from SZ-stranded slotted core Accessories Manufacturing (pictures) 41
42 Fibre Bending Excessive bending Causes additional loss May cause crack growth and fibre break The defined minimum bending radius shall be followed. 42
43 Branching of SZ-slotted Core Cable Strip and turn, Easy and quick operation 1 m Applications Branching joints Cable repair Route changes Alternate stranding direction Fibre is loosened by opening the stranding 43
44 Pulling Head for Optical Fibre Cable Applies the pulling force to the central strength member Pulling to be done using pulling grid Maximum pulling force 2500 N 40 mm 16 mm 13,5 mm 3,4 mm FXVP Detent screw (4 pcs.) 44
45 Cable Blowing Pressurised air Combined air blowing and pushing Large installation distances Low pulling forces in cable High speed / low cost Cable duct 45
46 Fusion Splicer 46
47 Joint Closures 47
48 Patch Panel 48
49 Optical Time Domain Reflectometer (OTDR) Power (dbm) a e P 1 P 2 b c d 1 2 Time (µs) or distance (m) a Near end reflection b Fibre loss c Splice loss d Reflective splice (connector) e Far end reflection Based on optical backscattering and reflections Loss distribution within fibres, splice locations, fibre length, fibre break localisation, etc 49
50 Contents Optical fibres and their characteristics Cable constructions Cable tests Installation, jointing and terminating Manufacturing (pictures) Manufacturing of slotted core Fibre laying Sheathing Testing 50
51 Fibre Stranding 51
52 Sheathing 52
53 Testing 53
54 Selection Criteria of Fibre type, number of fibres Transmission needs Future needs Cable construction Laying and installation method Environment Properly planned and constructed optical fibre cable route may satisfy your needs for decades! 54
55 55
56 Fibre Optics Flash Cord 2002 book for Telecommunications and Datanetworks, 128 pages Order by : 56
Data sheet OpDAT universal cable 1x24 OM4 - bend insensitive
Illustrations Principle diagram Page 1/7 Product specification installation cable U-DQ(ZN)BH universal fiber optic cable for indoors/outdoors with central or stranded loose tube bend insensitive fiber
More informationDuct Cable GYTS-144B1.3
Optical Fibre Cable Technical Specification Duct Cable GYTS-144B1.3 Xcom Ltd All rights reserved 1. Scope This Specification covers the design requirements and performance standard for the supply of optical
More informationFiretuf OFC-UT-CST Fire resistant Armoured Central Tube Cable, variant in red
Indoor/Outdoor steel tape armoured (CST) double LSHF-FR sheathed optical cable with 2 24 fibres. VDE: A/I-DQ(ZN)H(SR)H 3rd party verification of the fire tests by BUREAU VERITAS December 2014 OFC-UT-CST
More informationFiretuf OFC-UT-CST Fire resistant Armoured Central Tube Cable, variant in red
OFC-UT-CST Fire resistant Armoured Indoor/Outdoor steel tape armoured (CST) double LSHF-FR sheathed optical cable with 2 24 fibres. VDE: A/I-DQ(ZN)H(SR)H 3rd party verification of the fire tests by BUREAU
More informationData sheet OpDAT mini breakout cable 24x1 OM4 - bend insensitive
Page 1/8 Illustrations Principle diagram See enlarged drawings at the end of document Product specification mini-breakout installation cable U-VQ(ZN)H laser-optimized, bend insensitive fiber UV-resistant,
More informationData sheet OpDAT breakout cable 12x1 OM4 - bend insensitive, class Dca s1 d1 a1
Page 1/9 Illustrations Principle diagram See enlarged drawings at the end of document Product specification connection cable I-V(ZN)HH breakout cable for direct connector termination for indoors and outdoors
More informationOptical Fibre Cable Technical Specification. Duct Cable GYTA-72B1.3
VersionGYTA-72B1.3 Optical Fibre Cable Technical Specification Duct Cable GYTA-72B1.3 Yangtze Optical Fibre and Cable Joint Stock Limited Company All rights reserved www.yofc.com All Rights Reserved Copyright
More informationGUCN. Central Loose Tube Cables Universal Indoor / Outdoor - Corrugated Steel Tape Armor (CST) A/I-DQ(ZN)(SR)H Full Rodent Protection v13.
GUCN Central Loose Tube Cables Universal Indoor / Outdoor - Corrugated Steel Tape Armor (CST) A/I-DQ(ZN)(SR)H Full Rodent Protection 07-07-05 v3.0 Ordering Information Belden Part Numbers Fibre Description
More informationoutdoor and indoor campus backbone, building backbone (riser) FDDI, Gigabit Ethernet and ATM Easy to install direct burial halogen-free
GUSN Central Loose Tube Cables (Distribution) Universal Indoor/ Outdoor A/I-DQ(ZN)BH Standard Rodent Protection 05-04-8 v0.0 Ordering Information Belden Part Numbers Fibre Description / count 4 6 8 6 4
More informationIndustrial Fiber Optic Cables, LSZH Corrugated Armored Cable, Fibers
Features and Benefits Corrugated armor Mechanical protection Low-smoke/zero-halogen (LSZH ) sheath Key life-safety benefit Meets cyclic impact and chemical resistance test Superior performance Tray-rated
More informationGCRG. Multi Loose Tube Cables Universal Indoor / Outdoor A/I-DQ(ZN)BH Improved Rodent Protection v7.0. Ordering Information.
GCRG Multi Loose Tube Cables Universal Indoor / Outdoor A/I-DQ(ZN)BH Improved Rodent Protection 05-05-7 v7.0 Ordering Information Belden Part Numbers Fibre Description / count 4 8 8 4 30 36 6.5/5-OM GCRG04
More informationØ 1000 * 588 mm 50 kg
GUCN Central Loose Tube Cables Universal Indoor / Outdoor - Corrugated Steel Tape Armor (CST) A/I-DQ(ZN)(SR)H Full Rodent Protection Ordering Information Belden European Part Numbers Fibre type / count
More informationSpecial Provision No. 683S28 December 2017
FIBRE OPTIC COMMUNICATION CABLES, AERIAL ON MESSENGER CABLE - Item No. FIBRE OPTIC COMMUNICATION CABLES, AERIAL ON MESSENGER CABLE (TEMPORARY) - Item No. Special Provision No. 683S28 December 2017 1. SCOPE
More information2016 CDM Smith All Rights Reserved July 2016 SECTION FIBER OPTIC DATA NETWORK
PART 1 GENERAL 1.01 SCOPE OF WORK SECTION 27 12 23 FIBER OPTIC DATA NETWORK A. Furnish, install, terminate, and test all fiber optic equipment and cabling necessary for a complete and functional data highway
More informationEasy to install in ducts, tunnels and trenches by means of compressed air or pulling wire. Suitable for direct burial (crush 400 N/cm).
GCDG Multi Loose Tube Cables Universal Indoor / Outdoor - Corrugated Steel Tape Armor (CST) A/I-DQ(ZN)H(SR)H Full Rodent Protection Ordering Information Belden European Part Numbers Fibre type / count
More informationMultipurpose Cables (indoor/outdoor), Multipurpose central tube cable (maxibundle) with glass yarn armouring A-DQ(BN)H 4-24
Features and Benefits Laminated swelling glass yarns Improved rodent resistance and longitudinal water protection UV and microbe resistant Can be directly buried or installed in ducts Metal-free cable
More informationGBRD. Multi Loose Tube Cables Outdoor A-DQ(ZN)B2Y Improved Rodent Protection. Ordering Information. Applications. Features & Benefits
GBRD Multi Loose Tube Cables Outdoor A-DQ(ZN)B2Y Improved Rodent Protection Ordering Information Belden European Part Numbers Fibre type / count 24 36 48 60 72 62.5/125-OM1 GBRD124 GBRD136 GBRD148 GBRD160
More informationSumitomo Fiber Specification SE-6** Non-Zero Dispersion Shifted Single-Mode Fiber. PureGuide SM Optical Fiber, TIA Type IVd. Issued: November 2003
Sumitomo Fiber Specification SE-6** Non-Zero Dispersion Shifted Single-Mode Fiber PureGuide SM Optical Fiber, TIA Type IVd Issued: November 2003 78 Alexander Drive, Research Triangle Park, NC 27709 Phone
More informationSPECIAL ELECTRICAL AND OPTICAL CABLES
SPECIAL ELECTRICAL AND OPTICAL CABLES INTRODUCTION The new high-speed trains and the sensible increase of the traffic, with congested lines, is the result of the latest development of the rail sector.
More informationDNVGL-CP-0402 Edition February 2016
CLASS PROGRAMME Type approval DNVGL-CP-0402 Edition February 2016 The electronic pdf version of this document, available free of charge from http://www.dnvgl.com, is the officially binding version. FOREWORD
More informationSumitomo Fiber Specification SE-9** Non-Zero Dispersion Shifted (NZDF) Zero Water Peak Large Effective Area Single Mode Fiber
Sumitomo Fiber Specification SE-9** Non-Zero Dispersion Shifted (NZDF) Zero Water Peak Large Effective Area Single Mode Fiber PureGuide -LA SM Optical Fiber, TIA Type IVd ITU G.655 C and D Compliant Issued:
More informationTELECOM SOLUTIONS CABLE CATALOGUE INNOVATIVE FIBRE OPTIC CABLE SOLUTIONS
TELECOM SOLUTIONS CABLE CATALOGUE INNOVATIVE FIBRE OPTIC CABLE SOLUTIONS TKF TECHNOLOGICAL LEADERSHIP IN CONNECTIVITY SOLUTIONS Since its establishment in 90 TKF developed from a cable producer to a leading
More informationGUSN. Central Loose Tube Cables (Distribution) Universal Indoor/ Outdoor A/I-DQ(ZN)BH Standard Rodent Protection. Ordering Information.
GUSN Central Loose Tube Cables (Distribution) Universal Indoor/ Outdoor A/I-DQ(ZN)BH Standard Rodent Protection Ordering Information Belden European Part Numbers Fibre type / count 2 4 6 8 12 16 24 62.5/125-OM1
More informationFiber Optic and CAT 5, 6, 7 and 8 Installer Premise Cabling
Hands-On Fiber Optic and CAT 5, 6, 7 and 8 Installer Premise Cabling Certification Course Description This Hands-On course is customized to give Technicians the confidence and skills to maintain Fiber
More informationFibre optic media options and trends
Fibre optic media options and trends Presented by D Stockton & P Lascelles of Miniflex Ltd, branded as m2fx 23 February 2012 1 Contents Cable constructs Indoor/outdoor LSZH Armouring Micro Bends Singlemode,
More informationFibre Specification Standards
Fibre Specification Standards User Manual The most important thing we build is trust Cobham Wireless - Coverage Table of Contents 1. Single-mode Fibre to ITU-T Recommendation G.652 3 2. SC/APC Mated Pair
More informationINTERIM EUROPEAN I-ETS TELECOMMUNICATION June 1997 STANDARD
INTERIM EUROPEAN I-ETS 300 644 TELECOMMUNICATION June 1997 STANDARD Source: ETSI TC-TM Reference: DI/TM-01021 ICS: 33.020 Key words: Fibre, cable, optical, transmission Transmission and Multiplexing (TM);
More informationGUSA. Central Loose Tube Cables (Distribution) Universal Indoor/ Outdoor A/I-DQ(ZN)BH Standard Rodent Protection. Ordering Information.
GUSA Central Loose Tube Cables (Distribution) Universal Indoor/ Outdoor A/I-DQ(ZN)BH Standard Rodent Protection Ordering Information Belden European Part Numbers Fibre type / count 2 4 6 8 12 62.5/125-OM1
More informationOPTICAL. Micromodule DW About Us. > IEC nd Ed. According to. > EN nd Ed. FTTx
fibrewave About Us Prysmian is a global market leader in optical cables, supplying a major part of the world s optical cable needs. With a strong heritage of highly advanced R&D, Prysmian is at the leading
More informationFIBRE OPTIC COMMUNICATION CABLES, IN DUCTS - Item No. FIBRE OPTIC COMMUNICATION CABLES, IN DUCTS (TEMPORARY) - Item No.
FIBRE OPTIC COMMUNICATION CABLES, IN DUCTS - Item No. FIBRE OPTIC COMMUNICATION CABLES, IN DUCTS (TEMPORARY) - Item No. Special Provision No. 683S01 December 2017 1. SCOPE This Special Provision covers
More informationFibre Optic Cable. Catalogue.
Fibre Optic Cable Catalogue www.fibrefab.com About The FibreFab Group FibreFab Established in 1992, FibreFab is a leading provider of fibre optic connectivity products used in data communications and Telecommunication
More information13-SDMS-02 REV. 00 SPECIFICATIONS FOR NON-METALLIC, TIGHT BUFFERED & RETRACTABLE, MICRO FIBER OPTIC CABLE FOR INTERNAL INSTALLATION
13-SDMS-02 REV. 00 SPECIFICATIONS FOR NON-METALLIC, TIGHT BUFFERED & RETRACTABLE, MICRO FIBER OPTIC CABLE FOR INTERNAL INSTALLATION This specification is property of SEC and subject to change or modification
More informationFiber Optics for Todays Industry Applications
Hands-On Fiber Optics for Todays Industry Applications (A Non-Telephone Company Course) Course Description This Hands-On course is designed to provide technicians with a practical understanding and Hands-On
More informationFibre (TIA) Field Test Specification
This document has been prepared to aid consultants or engineers in developing contractual specifications covering the testing of duplex fibre optic cabling installations. It is offered as a general guide.
More informationHands-On Fiber Optics ISP/OSP - Advanced Combo- Tech
Hands-On Fiber Optics ISP/OSP - Advanced Combo- Tech Course Description This Hands-On 3-day course has been customized to provide technicians with a practical understanding of fiber optic theory and fiber
More information--> Buy True-PDF --> Auto-delivered in 0~10 minutes. YD/T Translated English of Chinese Standard: YD/T
Translated English of Chinese Standard: YD/T1447-2013 www.chinesestandard.net Sales@ChineseStandard.net COMMUNICATION INDUSTRY STANDARD OF THE PEOPLE S REPUBLIC OF CHINA YD ICS 33.180.10 M 33 Replacing
More informationVTI Services Technical Bulletin (TB) OTDR Measurement of Installed Optical Fibre Cabling Permanent Links and Links
VTI Services Technical Bulletin (TB) OTDR Measurement of Installed Optical Fibre Cabling Permanent Links and Links TB Number 004 This bulletin is supplied for information only and is intended to provide
More informationHands-On Fiber Optic ISP / OSP Combo-Tech Splicing, Termination & Testing
Hands-On Splicing, Termination & Testing BICSI CECs This course has been approved for CEC credits by BICSI. Please read below for a breakdown of the credits that we offer for this course. For more information
More informationGOF Indoor and Outdoor Cables. Documentation VWL Version 1.1 Source Code M
GOF Indoor and Outdoor Cables Documentation VWL 064.503 Version 1.1 Source Code M GOF Installation Cables Cable matrix / overview Source code M Use Indoor In- / Outdoor Outdoor Type of cable Breakout Mini-
More informationGOF Indoor and Outdoor Cables. Documentation VWL Version 2.2 Source Code R
GOF Indoor and Outdoor Cables Documentation VWL 064.504 Version 2.2 Source Code R GOF Installation Cables Cable matrix / overview Source code: R Use Indoor In- / Outdoor Outdoor Type of cable Breakout
More informationHands-On CAT 5/6 & Fiber Optic Installer
Hands-On BICSI CECs This course has been approved for CEC credits by BICSI. Please read below for a breakdown of the credits that we offer for this course. For more information regarding BICSI please visit
More informationindustry solutions: military
industry solutions: military MC industry Solutions: Military A tradition of leadership in technology, product performance for military applications Optical Cable Corporation is a leading manufacturer of
More information4120 Fire Alarm Network Reference
4120 Fire Alarm Network Reference Features Autocall 4120 Fire Alarm Network communications are available for wired or fiber optic connections Wired communications are available on Network Interface Cards
More informationCore identification code. J-YY...BD Indoor Cable. J-YY...BD Indoor Cable. VDE 0815 Mutual capacitance. J-YY...BD Indoor Cable. Cu conductor 0.
Indoor cables J-YY...BD Indoor J-Y(ST)Y..LG Indoor Comparable products UNITRONIC J-2Y(ST)Y...ST III BD see page 271 Indoor telephone cables transmit analogue or digital signals In news and communication
More informationSTANDARD CONFORMANCE
STANDARD CONFORMANCE IEC 60331-11, Tests for electric cables under fire conditions- Circuit integrity- Fire alone at a flame temperature of at least 750C IEC 60331-21, Tests for electric cables under fire
More informationFiber Optic Distribution Cables (6-144 Fibers)
900um Buffered Aramid Yarn Strength Members Outer 6 or 12 Subunit Central Strength Member Outer Ripcord Single Unit Cable 6-24 Multi-Unit Cable 24-144 Description: AMP NETCONNECT distribution cables are
More informationFibre Optic Basics FIA Summer Seminar 2014
Fibre Optic Basics FIA Summer Seminar 2014 Andrew Cole Theory Basics Characteristics of Light What is Light? An electromagnetic wave, which like other waves, has a frequency (f), velocity (v) and a wavelength
More informationMain features of the JETnet system
Main features of the JETnet system Proven concept. The JETnet microduct system of Draka Comteq is a well-established system used on a worldwide basis by many reputable companies. JETnet continues to maintain
More informationSpecification No.CSC-131/R-1/DH//UH/P&D/ Technical Specifications. for 24 Fiber/48 Fiber Unarmoured. Underground Fibre.
Specification No.CSC-131/R-1/DH//UH/P&D/2016-17 Technical Specifications for 24 Fiber/48 Fiber Unarmoured Underground Fibre Optic Cabling Issue Month:June-2016 (CSC Amendment date 14.06.2016) Common Specification
More informationDraft ES V1.1.1 ( )
Standard Transmission and Multiplexing (TM); Passive optical components; Fibre optic mechanical splices for single-mode optical fibre communications systems; Common requirements and conformance testing
More informationBasic Professional Fiber Optic Installation
Basic Professional Fiber Optic Installation QUICK SUMMARY Length: 32 hours; or 40 hours with Fiber Optic Association CFOT certification Hands-on Activities: 40 activities, 70-75 % Text/Field Reference:
More informationDetection of Solvents using a Distributed Fibre Optic Sensor
Detection of Solvents using a Distributed Fibre Optic Sensor Alistair MacLean, Chris Moran, Walter Johnstone, Brian Culshaw, Dan Marsh, Paul Parker. A fibre optic sensor that is capable of distributed
More informationA. General: Horizontal and backbone cabling shall be verified in accordance with ANSI/TIA/EIA-568-C and the addendum for fiber optic testing.
3.4 TESTING OF FIBER OPTICS CABLING A. General: Horizontal and backbone cabling shall be verified in accordance with ANSI/TIA/EIA-568-C and the addendum for fiber optic testing. B. General: In the event
More informationProduct Specification Qualification Test Report
PS 88 / DMI PC SM / 6/5 DIAMOND Test & Calibration Laboratory STS 333 / SCS 11 Product Specification Qualification Test Report DMI PC SM DIAMOND SA Via dei Patrizi 5 CH-6616 LOSONE Tel. +41 91 785 45 45
More informationThe Optical Time Domain Reflectometry and the Fusion Splicer Laboratory exercise
The Optical Time Domain Reflectometry and the Fusion Splicer Laboratory exercise 1 The purpose of the exercise...2 2 Background...2 2.1 Introduction to scattering and attenuation...2 2.2 Introduction to
More informationFTTX Solutions Mini Rapid Fiber Distribution Terminal (RDT)
TE Connectivity's (TE) FTTX infrastructure solutions are designed from the ground up to meet the unique requirements of FTTX networks. Designed for operational efficiency and scalability, TE s FTTX solutions
More informationSTANDARD TEST PROCEDURE PRE-TEST QUALITY OF OPTIC FIBRE CABLE ON DRUMS TYPE OF CABLE :
PROCEDURE PRE-TEST QUALITY OF OPTIC FIBRE CABLE ON DRUMS STANDARD TEST PROCEDURE PRE-TEST QUALITY OF OPTIC FIBRE CABLE ON DRUMS TYPE OF CABLE : 1) SINGLE MODE 2) MULTI-MODE IN EXCESS OF 100 METRES PRC-00107
More informationECP OPTICAL FIBRE SPLICING, TESTING AND COMMISSIONING REQUIREMENTS
Network(s): Summary: ENGINEERING COMMISSIONING PROCEDURE ECP 11-0009 OPTICAL FIBRE SPLICING, TESTING AND COMMISSIONING REQUIREMENTS EPN, LPN, SPN This standard details the requirements for the splicing,
More informationOFS IV Optical Fibre System
OFS IV Optical Fibre System FOR ALL FIBRE OPTIC USERS Fibre optic training has assumed great importance in today s world of widespread fibre optic usage whether in telecommunications or railways, industrial
More informationFiber Optic Patch Cord and Pigtails
Fiber Optic Patch Cord and Pigtails Description The optical fiber patch cords are fitted at both ends with same connector types or different connector types. Our fiber optic patch cords are ultra reliable
More informationTE CONNECTIVITY <fiber count> <fiber type> <flame rating> MM/YY SO<shop order number> XXXXX FEET
Optic Backbone Distribution Cables 900um Buffered Aramid Yarn Strength Members Outer 6 or 12 Subunit Central Strength Member Outer Ripcord Single Unit Cable 6-24 Multi-Unit Cable 24-144 Description: TE
More informationOptical Time Domain Reflectometry (OTDR)
Experimental Optics Contact: Helena Kämmer (helena.kaemmer@uni-jena.de) Last edition: Helena Kämmer, January 2017 Optical Time Domain Reflectometry (OTDR) Contents 1 Overview 3 2 Safety issues 3 3 Theoretical
More informationDome Fiber Optic Closure SC-221
Dome Fiber Optic Closure SC-221 General Information SC-221 fiber optic closure protects the fiber optic splices from harsh external environment conditions. It is designed for many network segments and
More informationThe Quality Connection. BETAflam Fire Resistant Safety Cables
The Quality Connection BETAflam Fire Resistant Safety Cables BETAflam Contact Your personal customer number To offer you a more efficient service, we kindly ask you to mention your personal customer number
More informationFujikura-70S Single Fibre Fusion Splicer
Fujikura- Single Fibre Fusion Splicer Features Core-to Core alignment, Dual Axis observation system. World s quickest splicing 6sec. / tube-heating 9sec. Minimal manual operation. Splice in 4 steps. Multi-functional
More informationFire Control Panels. Multiple Signal Fiber Optic Modems and Accessories for Panel and Remote Mounting. Features. Operation.
UL, ULC Approved* Fire Control Panels Multiple Signal Fiber Optic Modems and Accessories for Panel and Remote Mounting Features Converts multiple fire alarm communications signals into a single fiber optic
More information(Notices) EUROPEAN COMMISSION
14.8.2012 Official Journal of the European Union C 245/1 IV (Notices) NOTICES FROM EUROPEAN UNION INSTITUTIONS, BODIES, OFFICES AND AGENCIES EUROPEAN COMMISSION Commission communication in the framework
More informationLloyd s Register Type Approval System Test Specification Number 3
Working together for a safer world Lloyd s Register Type Approval System Test Specification Number 3 July 2015 Performance Test Specification for Equipment to be used in Marine Applications: Electric Cables
More informationReflectance, The Hidden Danger That Increases Bit Error Rates in Your Fiber Networks Denver, May 22nd, 2010
Reflectance, The Hidden Danger That Increases Bit Error Rates in Your Fiber Networks Denver, May 22nd, 2010 Adrian Young Sr. Customer Support Engineer Foreword Reflectance is measured using an Optical
More informationM700-Series Multifunction OTDR
M700-Series Multifunction OTDR Test, Troubleshoot and Document Single-mode and Multimode Fiber Networks Test Modes Full Auto OTDR Normal (point-to-point) fiber cable construction testing and fault location
More informationSchedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK
2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Presley House Presley Way Crownhill Milton Keynes MK8 0ES United Kingdom Contact: Jeremy Hodge Tel: +44 (0) 1908 267300 Fax: +44 (0) 1908
More informationField Test Procedure for Optical Fibre Link Measurements
Application Notes Field Test Procedure for Optical Fibre Link Measurements Issued April 2014 Abstract After fiber optic cables are installed, spliced and terminated, they must be tested. For every fiber
More informationITU-T L.404. Field mountable single-mode optical fibre connectors
I n t e r n a t i o n a l T e l e c o m m u n i c a t i o n U n i o n ITU-T L.404 TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU (08/2017) SERIES L: ENVIRONMENT AND ICTS, CLIMATE CHANGE, E-WASTE, ENERGY
More informationAcceptance Requirements. Fibre Optic Systems. Revised 12/2017. December 5th, Alexander Kölbel
December 5th, 2017 Acceptance Requirements Fibre Optic Systems Revised 12/2017 Alexander Kölbel +49 6190 8880-40 alexander.koelbel@datwyler.com Dätwyler Cables GmbH, Auf der Roos 4-12, 65795 Hattersheim,
More informationNote: Asterisk ** denotes that the standard compliance is optional, depending on the oxygen index of the PVC compound and the cable design.
ADDISON Flame Retardant RG59 B/U Coaxial cables Plain copper wire braid PE Solid Bare Copper PVC Outer Sheath APPLICATION The cables are designed for CCTV, security, smoke detection and evacuation monitoring
More informationSimplex ES Network. ES Net Network Applications, Communications, Options and Specifications. ES Net features. UL, ULC Listed*
Simplex ES Network UL, ULC Listed* ES Net features ES Network (ES Net) is a high bandwidth (100 Mbps) IP based fire alarm network that supports up to 99 nodes and uses industry standard network technology
More informationFiber Tes)ng 101 Essen)als Every Network Analyst Needs to Know. David S(llwell BCNET Oscar Rondon BCNET Gwenn Amice - EXFO
Fiber Tes)ng 101 Essen)als Every Network Analyst Needs to Know David S(llwell BCNET Oscar Rondon BCNET Gwenn Amice - EXFO Workshop format The Workshop is going to start with three short lecture style power
More informationFire alarm cables. for highest safety requirements TRADITION INNOVATION PASSION
Fire alarm cables for highest safety requirements TRADITION INNOVATION PASSION Datwyler Datwyler Cabling Solutions is an internationally operating company with its headquarters in Switzerland and affiliates
More informationDNVGL-CP-0401 Edition February 2016
CLASS PROGRAMME Type approval DNVGL-CP-0401 Edition February 2016 The electronic pdf version of this document, available free of charge from http://www.dnvgl.com, is the officially binding version. FOREWORD
More informationCHALLENGE OF THE NEW OPTICAL FIBRE TECHNOLOGIES
THE CHALLENGE OF THE NEW OPTICAL FIBRE TECHNOLOGIES 17th September 2002 Botanical Gardens Birmingham The Way We Were 1GbE and 10GbE OF Categories Channel Design Cleaning SFF Connecting Hardware Testing
More informationSPECIFICATIONS - DETAILED PROVISIONS Section Fiber Optic Cabling and Components C O N T E N T S
Revised 04/14/16 SPECIFICATIONS - DETAILED PROVISIONS Section 16890 - Fiber Optic Cabling and Components C O N T E N T S PART 1 - GENERAL... 1 1.01 DESCRIPTION... 1 1.02 RELATED SECTIONS... 1 1.03 REFERENCE
More informationfire resistant cables
Building Technology fire resistant cables Special electrical and optical cables www.tecnikabel.com Special electrical and optical cables 2 INTRODUCTION Structured cabling solutions. Tecnikabel can provide
More informationEnsuring Cabling Performance in the Customer-Owned Outside Plant
Ensuring Cabling Performance in the Customer-Owned Outside Plant Needs to be able to qualify the installation to validate bandwidth requirements are met Future high bandwidth applications Future Proof
More informationEvolution of Cable Fire Safety Standards in Australia
Evolution of Cable Fire Safety Standards in Australia INTRODUCTION Fire safety standards for electrical cables have evolved over the past few decades to the extent that they are now well established along
More informationDNVGL-CP-0399 Edition March 2016
CLASS PROGRAMME Type approval DNVGL-CP-0399 Edition March 2016 The electronic pdf version of this document, available free of charge from http://www.dnvgl.com, is the officially binding version. FOREWORD
More informationSECTION COMMUNICATIONS OPTICAL FIBER BACKBONE CABLING
SECTION 27 13 23 COMMUNICATIONS OPTICAL FIBER PART 1 - GENERAL 1.1 SUMMARY A. Section Includes the following: 1. 50/125-micrometer, optical fiber cabling. 2. Cable connecting hardware, termination panels,
More informationCATEGORY 6A FTP RJ45 SOLUTION
CATEGORY 6A FTP RJ45 SOLUTION Clipsal titanium Patch Cord Clipsal titanium LSZH Patch Cord Clipsal titanium Keystone Jacks Clipsal titanium Modular Jacks Clipsal titanium Patch Panels Clipsal titanium
More informationWG Buried Fibre Cable Long Perimeter Detection System
WI CODE : 11954 Telephone : +44 (01295 756300 Fax : +44 (0)1295 756302 E-Mail : info@wi-ltd.com Website : www.wi-ltd.com WG Buried Fibre Cable Long Perimeter Detection System The WG Buried Cable Long Perimeter
More informationIDENTIFYING TRAY CABLES FOR YOUR NEXT INSTALLATION A WHITE PAPER
IDENTIFYING TRAY CABLES FOR YOUR NEXT INSTALLATION A WHITE PAPER Published 3/23/2012 T hough rapidly increasing in popularity, tray cables are still a point of confusion for many. While the term tray cable
More informationBroadband System - H
Broadband System - H Satellites are spaced every 2nd degrees above earth "C" Band Toward satellite 6.0 GHz Toward earth 4.0 GHz "L" Band Toward satellite 14.0 GHz Toward earth 12.0 GHz TV TRANSMITTER Headend
More informationThe Rise of Tier 2 Testing
The Rise of Tier 2 Testing Why enterprises today demand better visibility into their fiber infrastructure Unprecedented demand for more bandwidth, faster network speeds, lower latency, and improved data
More informationCatalogue Power Cables
Catalogue Power Cables Conductores Tecnológicos S.A. www.contecsa.es Index of Cables Page Introduction 13 RV 14 RVMV 15 RVSV 16 RVFV 17 Conductores Tecnológicos S.A. 2 www.contecsa.es INTRODUCTION Power
More informationAQ7275 OTDR Optical Time Domain Reflectometer
AQ7275 OTDR Optical Time Domain Reflectometer Wide range of models available Supporting FTTH to core networks Short dead zone (0.8 m) High dynamic range (45 db) Dead zone Bulletin AQ7275-02E Meets a broad
More informationSTANDARD FOR INDOOR-OUTDOOR OPTICAL FIBER CABLE
ANSI/ICEA S-104-696-2001 STANDARD FOR INDOOR-OUTDOOR OPTICAL FIBER CABLE Publication S-104-696 First Edition - September 2001 Published By Insulated Cable Engineers Association, Inc. Post Office Box 1568
More informationProduct Specification CAT 6 UNSHIELDED PATCH CORDS
Product 108-93017 Specification 23/Nov/06 Rev. A CAT 6 UNSHIELDED PATCH CORDS 1. SCOPE 1.1 Content This specification describes performance and material requirements and tests procedures for NETCONNECT
More informationITU-T L.12. Optical fibre joints SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE PLANT
INTERNATIONAL TELECOMMUNICATION UNION ITU-T L.12 TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU (05/2000) SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE PLANT
More informationTraction Cable Radox 3 GKW
General Properties : Excellent high temperature, low temperature, ozone and weathering resistance, zero halogen, flame retardant, solder iron resistant, easily strippable, flexible. Application : Single
More informationEnsuring Cabling Performance in the Customer-Owned Outside Plant. Keith Foord Product Manager Greenlee Communications
Ensuring Cabling Performance in the Customer-Owned Outside Plant Keith Foord Product Manager Greenlee Communications Introduction: Outside plant fiber networks require low reflectance terminations for
More informationFLX380-30x FlexTester OTDR
Features 3rd generation hand-held, all-in-one OTDR, Source, Power Meter, VFL Icon-based LinkMap display with pass/fail for easy network analysis Patented in- or out-of-service testing from a single port
More informationFIRE RESISTANT CABLES
Conducting Value The Last Cable Standing FIRE RESISTANT CABLES 100/7b ISO 9001:2008 Certificate No. CS1-249 MANAGEMENT SYSTEMS Assessed to ISO 9001:2008 Cert/LPCB ref. 217 GOST ISO 9001-2011 (ISO 9001:2008)
More information