Hands On: Introduction to Safety Workshop Presented by Robert Jones Manufacturing in America March 14-15, 2018
|
|
- Fay Hunt
- 5 years ago
- Views:
Transcription
1 Hands On: Introduction to Safety Workshop Presented by Robert Jones Manufacturing in America March 14-15, 2018
2 Before we start A Penny for Your Thoughts At the end of the session, share your feedback via MiA App - and get a chance to win tickets to the Detroit Tigers baseball game!
3 Machine Safety Safety Process Chain The necessary steps towards a safe machine can be illustrated with a process chain. Risk assessment Risk reduction Proof Cutting disc > Cutting off Chips > Cutting, penetrating Transport rollers > Crushing and shearing Clamping plates > Crushing
4 Machine Safety Are Risk Assessments Required? Risk assessment Risk reduction Proof European Union : USA: DIRECTIVE 2006/42/EC (Machinery Directive) NFPA 79 ANSI B11.19 ANSI / RIA ANSI ASSE Z244.1 YES! All new & revised machine safety standards state that a Risk assessment MUST be performed
5 Machine Safety Methods of Risk Mitigation Safety Implementations Physical safety measures Barriers (e.g. guards, enclosures), protective clothing and equipment, floor markings Safety awareness General safety education courses, proper equipment training, regular internal safety evaluation Safety controls Input devices (e.g. sensors, pilot devices), safety evaluation devices, Output devices (e.g. contactors, motor starter protection)
6 Machine Safety Risk Assessment Process The following standards should be applied for the techniques to evaluate and assess these risks: For USA: ANSI B , Safety of Machinery; General Requirements And Risk Assessment. For Europe: EN ISO "Safety of machinery basic terminology, general principles for design risk assessment & risk reduction
7 Machine Safety Quantifying Risk Risk Risk assessment Risk reduction Proof
8 Machine Safety Determination of required SIL Risk Risk assessment Risk reduction Proof
9 Machine Safety Determination of required PL Risk Risk Risk assessment Risk reduction Proof
10 Machine Safety Typical Safety Circuit example SIL 3 / PL e wiring 24V or 115VAC Power Supply Redundancy ensures safety functionality even if a failure disables one channel Safety Controller Evaluation Fault detection and evaluation; opens the circuit in case of a failure. Reset Reactivates the safety circuit Sensors Initiate machine shut down OR Feedback Loop Monitors the correct operation of the contactor coils Positive Opening Guarantees that all NC contacts are in the open position when actuated Positive Driven (Mirror) Guarantees that NC contacts are not to be closed at the same time as the main contact 0V The Complete Safety Solution
11 Machine Safety Understanding Safety Levels - PL a Standard Switch and Contactor PL a allows NO contacts for Enabling Two-hand control Restart L1 L2 L3 The Complete Safety Solution
12 Open Closed Machine Safety Understanding Safety Levels - PL b 24 VDC PL b requires Sensors with positive opening contacts L1 L2 L3 0 VDC The Complete Safety Solution
13 Open Closed Machine Safety Understanding Safety Levels - PL c / SIL 1 24 VDC ON PL c / SIL 1 requires Sensors with positive opening contacts And Safety evaluation unit rated to SIL 1 L1 L2 L3 Feedback loop from contactor s NC contacts Q1 0 VDC The Complete Safety Solution
14 Open Closed Machine Safety Understanding Safety Levels - PL d / SIL 2 24 VDC ON PL d / SIL 2 requires Sensors with positive opening contacts Q1 L1 L2 L3 Safety evaluation unit rated to SIL 2 Feedback loop from contactor s NC contacts And Redundancy in sensor contacts Redundancy in contactors 0 VDC Q2 The Complete Safety Solution
15 Open Closed Machine Safety Understanding Safety Levels - PL e / SIL 3 24 VDC PL e / SIL 3 requires Sensors with positive opening contacts 0 VDC Q1 Q2 ON L1 L2 L3 Safety evaluation unit rated to SIL 3 Feedback loop from contactor s NC contacts Redundancy in sensor contacts Redundancy in contactors And Separate channels of evaluation for sensors The Complete Safety Solution
16 Machine Safety Risk Reduction Risk assessment Risk reduction Proof Solutions consist of three main components Detection Evaluation Reaction Very Important as this is how the safety function is defined when doing the calculations for SIL/PL levels
17 Detection Input Devices May Include Several or Just One of the Following: (Depending Upon Safety Category Desired) Mechanical Input Devices Emergency Stop (with or without enable or resets) Position Switch Interlock Switch
18 Detection Input Devices May Include Several or Just One of the Following: (Depending Upon Safety Category Desired) Electronic Input Devices Solenoid Interlock Gate Switches Magnet or RFID Position Switches Light Grids / Area Laser Scanners Encoder Position Switches Safety Mats
19 Detection Input Devices with Safety Protocol using Networks Mixed Safety Non-Safety Devices same Network AS-I Safe Profi Safe
20 Detection Flowchart - Guides you to the right Siemens Safety Solution To fit your applications safety functionality, as per your comfort level
21 Evaluation Safety Relay & Programmable Controllers May Include One, Several, or a Combination of the Following: (Depending Upon Safety Category Desired and Complexity) Safety Relays Configurable Safety Relays MSS (Modular Safety System)
22 Evaluation 3SK, Universal Functionality Simple Slim portfolio + Flexible + Extendable through modular product concept Combinable With motor starter SIRIUS 3RM1 Failsafe Multifunctional Parameterization via DIP switch or software + + Economic Simple and reduced wiring with usage of innovative device connector +
23 Evaluation Modular expandability of SIRIUS Safety Relays 3SK1 Reduction of wiring outlay and space saving despite higher functionality
24 Evaluation 3SK1 compared with 3SK2 3SK1 customer s requirement 3SK2 most simple logic more complex logic additional functions (e.g. Muting/Interlock) only wiring allowed time off delay complex time functions powerful outputs enhanced diagnostics simplification of commissioning less space consumption
25 Evaluation Parameterization, Configuration, Visualization Safety ES Software Allows for comprehensive documentation thanks to graphical Drag&Drop code interface Easy-to-use configuration tools turn complex wiring parameterization into straightforward software solutions Makes implementing advanced functions easy: Muting functionality Protective door monitoring Independent output functions
26 Evaluation Modular Safety System (3RK3) Designed to minimize the number of modules needed when multiple safety functions must be evaluated. 3RK3111/3RK3131 (Basic/Advanced central unit) 3RK3121/3RK3122 (Basic/Advanced central unit with ASI safe integration) Expansion modules, DP interface module, and diagnostic display available
27 Evaluation SIMATIC Failsafe CPUs Failsafe versions of the SIMATIC automation system integrate additional safety-related functions S7-1200F: High level functionality and flexibility. ET200SP F: Distributed controller for compact systems. S7-1500F: Greatest performance, flexibility and networking capability.
28 Reaction Output Devices May Include Several or Just One of the Following: (Depending Upon Safety Category Required & Operation Desired) Safety Contactors (Positively Driven Mirror Contacts) Safety Relays (Positively Driven Mirror Contacts) Safety Motor Starters (3RM1 / ET200S / ET200SP) Safety VFDs (G120 / S120)
29 Siemens Safety Integrated Safety Design Compliance - Safety Evaluation Tool The Safety Evaluation tool A free Internet-based tool for calculating safety functions ISO (successor standard of EN 954-1) IEC For documenting the results by a report Offers easy, identical handling for both standards Optimum support when using the Siemens products Safety Evaluation Tool Online Access SET Getting Started Document SET Tutorial (YouTube) Risk assessment Risk reduction Proof
30 Siemens Safety Integrated Machine Safety Services Risk Assessments Partners GP Strategies White Horse Safety Safety Validation Partner TÜV Rheinland of North America White Horse Safety The Complete Safety Solution
31 Wheat mill with variable feeding Requirements Alternating monitoring of cone or vessel manipulation-proof switches door interlock of service door (crushing mill) door interlock of service door (vessel) nearly no space in cabinet
32 Wheat mill with variable feeding Solution Solution with HW-parameterized Safety relays Solution with SW-parameterized Safety relays 3SK2
33 Wheat mill with variable feeding Solution Required 3SK1 Wiring Required 3SK2 Configuration
34 Material Feeding System: 3SK2 Example Tool Change/Access Inspection Station
35 Safety Controls Components: 3SK2 Example Detection Devices Emergency Stop - Global Evaluation Devices Programmable Safety Relay Reset Button Reaction Devices RFID Gate switch - Safety Motor Starter Light Curtain - Contactors Safety Motor Starter - Conveyor Contactor - Robot
36 Evaluating SIL Level: 3SK2 Example Hazard 1: Conveyor Severity: 3, Loss of fingers Frequency: 5, 1 Hr Occurrence: 2, Rarely Preventability: 1, Probable Total: 8 SIL Level: 1 Hazard 2: Robotic Arm Severity: 4, Loss of life Frequency: 3, > 2 Weeks to 1 Year Occurrence: 3, Possible Preventability: 5, Impossible Total: 11 SIL Level: 3
37 Safety ES Software: 3SK2 Example E-Stop and pushbutton inputs Cross-circuit detection with monitored start E-Stop global output Outputs to 3RM1 through backplane and to contactors 3SE6 Inputs Cross-circuit detection, automatic start 3SE6 Ouput to 3RM1 Wired output to 3RM1
38 Safety ES Software: 3SK2 Example Inputs from E-stop output block (M1, M2) and Light curtain (M3) Mirror E-stop condition output to LED (QM1) and E- stop and light curtain must not be tripped for contactor LED (QM2) to be on Red E-stop LED (QM1) Green contactor LED (QM2) Light curtain inputs and push button inputs, Input from E- stop output (Q5-C) Output to Contactors Light curtain and E-stop must not be tripped, controls contactors Contactor Feedback Contactors (Q1, Q3) and Auxiliary to LED (M3)
39 Hands On Demo Unit Layout: 3SK1 3SK1 Basic Unit Contactor Q1 E-Stop, Monitored Contacts Red Status LED Contactor Q2 Reset Button 5SJ4 2A Circuit Breaker
40 Task #1: 3SK1 SIL 1 Wiring Goal: Demonstrate the ease of setup and flexibility of the 3SK1 series with a SIL 1 configuration. Main take away items: Understand the application of SIL 1 safety measures in system design. Integrate the 3SK1 into a safety system to satisfy SIL 1 standards. The Complete Safety Solution
41 Task #1: 3SK1 SIL 1 wiring Technical Diagram The Complete Safety Solution
42 Task #1: 3SK1 SIL 1 wiring Recap Sensor with positive opening contacts Lower rate of failed detection from shorts and welds Safety evaluation unit rated to SIL 1 More reliability and higher level safety functions Picture of demo in SIL 1 configuration Feedback loop from contactor s NC contacts Provides feedback if contactor contacts weld The Complete Safety Solution
43 Task #2: 3SK1 SIL 3 wiring Goal: Demonstrate the ease of setup and flexibility of the 3SK1 series with a SIL 3 configuration. Main take away items: Understand the application of SIL 3 safety measures in system design. Integrate the 3SK1 into an existing system to satisfy SIL 3 standards.
44 Task #3: 3SK1 SIL 3 wiring Technical diagram The Complete Safety Solution
45 Task #3: 3SK1 SIL 3 wiring Recap Safety evaluation unit rated to SIL 3 More reliability and higher level safety functions Separate channels for each set of sensor contacts Failure of a single channel does not disable safety functionality Picture of demo in SIL 3 configuration The Complete Safety Solution
46 How did we do? Share your thoughts to win! Got 1 minute? Rate this seminar via MiA App for a chance to win Detroit Tigers tickets:
47 Seminar Slides After MiA, seminar slides will be available at:
48 Questions? Robert Jones 6750 Arnold Miller Pkwy Solon, OH Phone: (330)
Basics of Safety Applications
Basics of Safety Applications Unrestricted Siemens 2016 usa.siemens.com/controls Why Safety Technology? Protection of People Environment Page 2 Safety Process Chain The necessary steps towards a safe machine
More informationBasics of Safety Applications
Basics of Safety Applications Unrestricted Siemens 2016 usa.siemens.com/controls DISCLAIMER/ TERMS OF USE: THE INFORMATION PROVIDED HEREIN IS PROVIDED AS A GENERAL REFERENCE REGARDING THE USE OF THE APPLICABLE
More informationFunctional Safety of Machinery Presented by Greg Richards Manufacturing in America 02/22-23/2017
Functional Safety of Machinery Presented by Greg Richards Manufacturing in America 02/22-23/2017 AGENDA Definition of Safety? Machinery Safety Standards Comparison of ISO 13849-1 and IEC 62061 Safety-related
More informationManufacturing In America 2016 The Why, What & How of Machine Safety. MIATTO, Detroit MI March 23/24, 2016
Manufacturing In America 2016 The Why, What & How of Machine Safety MIATTO, Detroit MI March 23/24, 2016 Siemens Industry Inc. 2016 Siemens Safety Integrated Table of contents Safety What is it good for?
More informationSAFEMASTER PRO. The configurable safety system versatile and extendable. Our experience. Your safety.
SAFEMASTER PRO The configurable safety system versatile and extendable Our experience. Your safety. The modular safety system: Safe flexibility SAFEMASTER PRO: also as a stand-alone solution You may know
More informationSAFETY STANDARDS & SOLUTIONS MATERIAL HANDLING & INTRALOGISTICS
SAFETY STANDARDS & SOLUTIONS MATERIAL HANDLING & INTRALOGISTICS Renaat Mondelaers SICK Certified Functional Safety Application Expert CFSAE by SGS/TÜV Saar Mikaël Degent SICK Product Manager Industrial
More informationSafety Control Modules for Emergency Stop Circuits FF-SRS5988 FF-SRS5935 FF-SRS5925 FF-SRS5934 FF-SRS5924 TYPICAL APPLICATIONS APPROVALS DIMENSIONS
Safety Control Modules for Emergency Stop Circuits TYPICAL APPLICATIONS APPROVALS DIMENSIONS Single Channel Emergency Stop Module E-Stop circuits up to Category 2 (EN 954-) Sliding door protection Conveyors
More informationRFID Non-contact switches are designed to monitor hinged, sliding or removable guard doors. RFID technology provides increased tamper resistance.
RFID Non-contact Safety Switches RFID Non-contact switches are designed to monitor hinged, sliding or removable guard doors. RFID technology provides increased tamper resistance. Based on RFID technology,
More informationOperating instructions Safety-monitoring module SRB 302X3. 1 About this document
1 About this document Operating instructions... pages 1 to 6 Translation of the original operating instructions 1.1 Function This operating instructions manual provides all the information you need for
More informationFUNCTIONAL SAFETY INCREMENTAL ENCODERS MASTERING SPEED CONTROL
FUNCTIONAL SAFETY INCREMENTAL ENCODERS MASTERING SPEED CONTROL Up to SIL3 and PLe SENSATA TECHNOLOGIES LOCATIONS Manufacturing and warehouse centers Business centers Sales s ABOUT BEI SENSORS BEI Sensors
More informationOperating instructions Safety-monitoring module SRB 302X3. 1. About this document. Content
8 Appendix 8.1 Wiring examples...4 8.2 Start configuration...4 8.3 Sensor configuration...4 8.4 Actuator configuration...5 Operating instructions.............pages 1 to 6 Original 9 EU Declaration of conformity
More informationSafety. Detection. Control. SAFETY INTERFACES. Safety Interfaces and Relays. Product catalogue. Issue 1
Safety. Detection. Control. Issue 1 SAFETY INTERFACES Safety Interfaces and Relays Product catalogue OVERVIEW SAFETY INTERFACES AND RELAYS MG d1 PL d control unit for ReeR Magnus magnetic switches See
More informationSingle Source for Machine & Process Safeguarding Solutions
Single Source for Machine & Process Safeguarding Solutions Product Selection and Overview Enhanced worker safety through proper safeguarding Expert guidance from components to consulting Global product
More informationASIsafe Solution PROFIsafe
Functional Example CD-FE-I-049-V20-EN ASIsafe Solution PROFIsafe EMERGENCY STOP with Protective Door Monitoring according to Category 4 of EN 954-1, (with evaluation according to EN 62061, and EN ISO 13849-1:
More informationFunctional Safety incremental encoders
Functional Safety incremental encoders Up to SIL3 and PLe Mastering speed control 1 About BEI Sensors BEI Sensors production centre in Strasbourg, France BEI Sensors specializes in speed and position sensors
More informationSAFETY INTERFACES SAFETY INTERFACES AND RELAYS
SAFETY INTERFACES SAFETY INTERFACES AND RELAYS AD SR1 TYPE 4 INTERFACE FOR LIGHT CURTAINS Interface module between the safety light curtains EOS4 A, EOS2 A, Admiral AD, Admiral AX BK, Vision V with self-testing
More informationISIS SAFETY SYSTEM Installation guide
ISIS SAFETY SYSTEM Installation guide CAUTION This information is designed to help suitably qualified personnel install and operate Mechan Safety equipment. Before using this product, read this guide thoroughly
More informationSAFETY RELAY APPLICATION
SAFETY RELAY APPLICATION Application manual for YRB-4EML-31S safety relay Designation: Revision: Order No.: SAFETY RELAY APPLICATION 02 / 13.07.2016 605-000-728 This manual is valid for: YRB-4EML-31S from
More informationWe reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express
We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly forbidden. ABB 2CMT2016-005511 rev
More informationMACHINERY SAFEBOOK 5. Safety related control systems for machinery. Principles, standards and implementation. (Revision 5 of the Safebook series)
Safety related control systems for machinery Principles, standards and implementation (Revision 5 of the Safebook series) MACHINERY SAFBOOK 5 Content Chapter 1 Regulations 2 EU Directives and Legislation,
More informationEasy Implementation of the European Machinery Directive
Functional Safety of Machines and Systems Easy Implementation of the European Machinery Directive EN ISO 13849-1 EN 62061 Safety Integrated www.siemens.com/safety-integrated New Standards Support Mechanical
More informationF3SJ Overview. Three Versions available to meet your exact safety needs. Safety Light Curtains NEW! Introducing the F3SJ Series
Safety Light Curtains F3SJ Overview Introducing the F3SJ Series NEW! Three Versions available to meet your exact safety needs All versions conform to the latest Type 4, PLe and SIL3 requirements. F3SJ-E:
More informationOne giant leap for safety: AZM400.
One giant leap for safety: AZM400. Holding force: Unlocking against lateral force: Mechanical life: Protection class: Dimensions: Supply voltage: Electrical connection: AZM400 10,000 N 300 N > 1,000,000
More informationSafety Function: Single-beam Area Access Control (AAC)
Application Technique Safety Function: Single-beam Area Access Control (AAC) Products: Guardmaster Dual-input Safety Relay, Single-beam Area Access Control Sensors with E-stop Safety Rating: CAT. 4, PLe
More informationFunctional Safety of Machines and Systems Convenient Implementation of the European Machinery Directive
Functional Safety of Machines and Systems Convenient Implementation of the European Machinery Directive EN 954-1 EN ISO 13849-1 EN 62061 1 New standards support mechanical engineers Global standards, far-ranging
More informationSUPREMATouch. Modular Fire & Gas Detection System
SUPREMATouch Modular Fire & Gas Detection System Tel: +44 (0)8 9388 Email: info@ Fire & Gas Detection Solutions MSA permanent gas detection systems are used throughout the world to protect plant and personnel
More informationFor Complete Fire and Gas Solutions
Industrial Fire For Complete Fire and Gas Solutions 2 The Total Package What do you need from an integrated fire and gas system? In industrial fire and gas environments it s important to have a reliable
More informationSLC Receiver. SLC Transmitter
SLC Receiver READY TEST INPUT 5 OSSD MPCE 6 2 7 8 OSSD2 MPCE 2 SLC Transmitter Note: Numbers shown refer to pin # s on M2 connector Typical SLC Wiring to MPCEs using Relay Monitor Option (/29) SLC Receiver
More informationA magazine full of solutions. Machine tools
A magazine full of solutions Machine tools Safe solutions for your industry Machine tools Safety in system: Protection for man and machine - under this motto, the Schmersal Group develops and produces
More informationConnection of CET4-AP to Siemens ET 200S
Connection of CET4-AP to Siemens ET 200S Content Guard locking power on applied spring released according to EN ISO 14119 (open-circuit current principle)... 2 Components/modules used... 2 EUCHNER... 2
More informationSafety Sensor Eden AS-i Machine safety - Jokab Safety products
Safety Sensor Eden AS-i Machine safety - Jokab Safety products We develop products and solutions for machine safety The fact that the leading power and automation technology company, ABB, and a leader
More informationSafety Integrated. Terms and Standards Terminology in Machinery Safety. Introduction 1. Term. Attachment 3. Reference Manual
Introduction 1 2 Safety Integrated Attachment 3 s and Standards Reference Manual 04/2007 E86060-T1813-A101-A1-7600 Safety Guidelines This manual contains notices you have to observe in order to ensure
More informationSAFETY SERVICE RISK EVALUATION
SAFETY SERVICE RISK EVALUATION Customer: Date: Machinery: Referent (customer): Recording technician (safety service): Technical manager (safety service): Safety Service manager: Page 1 (In accordance with
More informationZERTI ~CERTIFICAJE. Certificate holder. Product tested. Manufacturer. Type designation. Codes and standards forming the basis of testing
ZERTI ~CERTIFICAJE t Product tested Active pto-electronic Protective Device responsive to Diffuse Reflectio (AOPDDR), Laser Scanner Certificate holder OMRON Scientific Technologies, Inc. 6550 Dumbarton
More informationROTOSCAN RS4 Safety Laser Scanner The flexible multitalent for people protection and versatile measuring tasks
ROTOSCAN RS4 Safety Laser Scanner The flexible multitalent for people protection and versatile measuring tasks PRODUCT INFORMATION ROTOSCAN RS4 Safety Laser Scanner Versatile use. Individual configuration.
More informationSe vuoi ricevere aggiornamenti e novità compila i tuoi dati - In attesa di iniziare
Se vuoi ricevere aggiornamenti e novità compila i tuoi dati - In attesa di iniziare Inserisci i tuoi dati Cliccando qui Compila i dati Safety Integrated in SIMATIC PCS 7 In attesa di inizare Verificate
More informationSUPREMATouch. Modular Fire & Gas Detection System
SUPREMATouch Modular Fire & Gas Detection System Fire & Gas Detection Solutions MSA permanent gas detection systems are used throughout the world to protect plant and personnel from hazardous gases in
More informationAutomation, Software und Informationstechnologie
Automation, Software und Informationstechnologie Report on the type approval of the Adjustable Frequency AC Drives PowerFlex 753 and 755 of Rockwell Automation Inc. Bericht-Nr.: 968/EZ 334.00/08 Datum:
More informationSafety & Signaling Mats. Sensing Bumpers Pressure-sensitive actuation with a large, cushioning surface that protects both. personnel and equipment.
CONTENTS pg.2 pg.3 Switch Products A diverse selection of products including ribbon switches, touchpads, foot and hand switches, tactile remote switches, vehicle sensing products, and innovative custom
More informationOriginal operating instructions Safety switch with guard locking AC901S AC902S
Original operating instructions Safety switch with guard locking AC901S AC902S 7390914/03 01/2017 Contents 1 Preliminary note...4 1.1 Explanation of symbols...4 2 Safety instructions...4 3 Items supplied...5
More informationSAFETY AUTOMATION MEASUREMENT AND CONTROL. Short Form Catalog. Catalog n.15
SAFETY AUTOMATION MEASUREMENT AND CONTROL Short Form Catalog Catalog n.15 CONTENTS SAFETY SENSORS EOS4 Type 4 light curtains Page 2 ADMIRAL Type 4 light curtains Page 4 JANUS Type 4 light curtains Page
More informationSiemens Process Automation End-user Summit- 2011
Siemens Process Automation End-user Summit- 2011 Experience. Technology. Community SIMATIC PCS 7 Process Safety Jean-Luc Gummersbach I IA AS PA PRM1 Global market trend in Process Safety Process Safety
More informationMachine Guarding and Safety
Machine Guarding and Safety Many thanks for clicking on this document. Please let us introduce selected highlights from our Machine Guarding and Safety offer. Related Industries: Food and Beverage Industry
More informationFirst of all, what is a safety-related
Safety-Related Control Systems First of all, what is a safety-related control system (often abbreviated to SRCS)? It is that part of the machine control system which prevents a hazardous condition from
More informationHighlights Solutions for you. DOLD - Our experience. Your safety.
Highlights Solutions for you. DOLD - Our experience. Your safety. Safety relays - with forcibly guided contacts The flat safety relays in series OA 5642/43/44 set new standards, with an installation height
More informationDatasheet - MZM 100 ST-SD2PREM-A
19.03.2014-10:31:42h Datasheet - MZM 100 ST-SD2PREM-A Solenoid interlock / MZM 100 Preferred typ Guard locking monitored Automatic latching Solenoid interlocks (for the protection of man) with innovating
More informationIEC61511 Standard Overview
IEC61511 Standard Overview Andre Kneisel Instrumentation Engineer Chevron C.T. Refinery SAFA Symposium 2011 August 5 th, 2011 Presentation Overview Provide some understanding of the key aspects of Functional
More informationM2500 Engine Controller Installation Manual
M2500 Engine Controller Installation Manual Revision: 23-04-2012 Page 1 Contents 1 Preface... 4 2 Installation... 5 3 Terminal Connections... 6 4 Inputs... 7 4.1 Power Supply... 7 4.2 Mode/ Control Inputs...
More informationCM Series. Safety, Technology & Innovation. Description. Approvals. Operation. Applications. Certificate of Conformity
CM Series Description Safety, Technology & Innovation Operating Instructions for Safety Switches KEEP THIS GUIDE FOR FUTURE REFERENCE This information is designed to help suitably qualified personnel install
More informationDatasheet - MZM 100 B ST2-SD2PREM-A
30.05.2015-14:46:12h Datasheet - MZM 100 B ST2-SD2PREM-A Solenoid interlock / MZM 100 Preferred typ Actuator monitored Automatic latching Solenoid interlocks (for the protection of man) with innovating
More informationSensaGuard TM Integrated Latch Installation Instructions
TM Integrated Latch Installation Instructions Certifications IMPORTANT: SAVE THESE INSTRUCTIONS FOR FUTURE USE Note: Refer to Technical Specifications for Certification information and ratings. 2 TM Installation
More informationPROTECT SRB 200EXi-1A
2 Installation up to zone 1/21 J S L1 0V X1 X3 S11 S12 S21 S22 Installation up to zone 2 A1 F1 F2 U B U EXi U i 0V S12 S22 X1 X3 K1 Logic K2 K1 K2 13 23 U EXi SRB 200EXi U B -1A U i K1 K2 PA PA A1 A2 13
More informationOriginal operating instructions Photoelectric safety sensors (safety light curtain / safety light grid) Protected area width (range) 0...
Original operating instructions Photoelectric safety sensors (safety light curtain / safety light grid) Protected area width (range) 0...12 m OY UK 704555 / 05 02 / 2018 Contents 1 Preliminary note...4
More informationNeed to reduce your terminal block wiring time? terminal blocks ALPHA FIX
Problem Solved. 2007 Siemens Energy & Automation, Inc. Need to reduce your terminal block wiring time? terminal blocks ALPHA FIX You and your customers require customized solutions that meet your cost
More informationSAFI250 Machine Safety. Introduction
SAFI250 Machine Safety Introduction Course Objectives Participant will: Explain safety categories Define SIL and PL Identify safety opportunities Discuss product options Setup basic operation of products
More informationSelection Guide. Logic: From basic to programmable network controllers» Safety Components. Output: Safety relays, servo systems, and inverters
Safety Components Selection Guide Complete lineup of safety components from input and logic to output»» Input: Door switches, light curtains, and laser scanners Logic: From basic to programmable network
More informationOriginal instructions Sense7-series Non-contact coded safety switch
Original instructions Sense7-series Non-contact coded safety switch ABB AB / Jokab Safety Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden www.abb.com/lowvoltage Read and understand this document Please
More informationDatasheet - MZM 100 ST2-1P2PWREM-A
30.05.2015-14:45:08h Datasheet - MZM 100 ST2-1P2PWREM-A Solenoid interlock / MZM 100 Preferred typ Guard locking monitored Automatic latching Solenoid interlocks (for the protection of man) with innovating
More informationReliability of Safety-Critical Systems Chapter 1. Introduction
Reliability of Safety-Critical Systems Chapter 1. Introduction Mary Ann Lundteigen and Marvin Rausand mary.a.lundteigen@ntnu.no & marvin.rausand@ntnu.no RAMS Group Department of Production and Quality
More informationAutomation at first hand. years
Automation at first hand. www.ifm.com WARRANTY years on ifm products Global presence and competent advice on site Worldwide direct and personal service: Whether via telephone, e-mail or in a personal
More informationMA Series. Safety, Technology & Innovation MA 12 MA 13. Description. Approvals. Operation. Applications. Declaration Conformity
, Technology & Innovation MA Series Operating Instructions for MA-12 & MA-13 Switches KEEP THIS GUIDE FOR FUTURE REFERENCE This information is designed to help suitably qualified personnel install and
More informationMachine Safety Sensing Control Products Automation Solutions
Your Single Source for Machine Safety Sensing Control Products Automation Solutions newest generation of safety & automation relay innovative sensing solutions Innovative & Traditional Machine Safety Automation
More informationOMRON SCIENTIFIC TECHNOLOGIES INCORPORATED ECDeclaration ofconformity
omron 9ti OMRON SCIENTIFIC TECHNOLOGIES INCORPORATED ECDeclaration ofconformity OMRON Scientific Technologies Incorporated (at 6550 Dumbarton Circle, Fremont, CA 94555-3605, U.S.A.), hereby declares that
More informationOperating Guide Safe Torque Off
ENGINEERING TOMORROW Operating Guide Safe Torque Off VLT Frequency Converters vlt-drives.danfoss.com Contents Operating Guide Contents 1 Introduction 2 1.1 Purpose of the Manual 2 1.2 Additional Resources
More information/ sicam SICAM Safety Full functionality for safety-critical applications Answers for infrastructure and cities.
www.siemens.com / sicam SICAM Safety Full functionality for safety-critical applications Answers for infrastructure and cities. More safety for your automation system Protect people and the environment
More informationMLDSET Light Beam Safety Device Sets for access guarding with muting function
2 rue René Laennec 51500 Taissy France Fax: 03 26 85 19 08, Tel : 03 26 82 49 29 E-mail:hvssystem@hvssystem.com Site web : www.hvssystem.com MLDSET Light Beam Safety Device Sets for access guarding with
More informationFuji Electric s Approach to Machinery Safety and Functional Safety -Total Safety-
Fuji Electric s Approach to Machinery Safety and Functional Safety -Total Safety- Akihiko Kohanawa Masami Hasegawa 1. Introduction Serious accidents involving machinery and industrial plants have occurred
More informationThe agri-motive safety performance integrity level Or how do you call it?
TÜV Rheinland InterTraffic GmbH Safety in Transportation 4 The agri-motive safety performance integrity level Or how do you call it? Dipl.-Ing. Sebastian Gräfling, TÜV Rheinland InterTraffic GmbH Contents
More information/ / 2018
Original operating instructions Photoelectric safety sensors (safety light curtain / safety light grid) with IP69K protective tube Protected area width (range) 0...10 m OY4xxS UK 704859 / 05 02 / 2018
More informationSTEAMPAK Series BurnerPAK BMS Burner Management Systems
BurnerPAK BMS Burner Management Systems Sequence of operation, ignition and control of burners Meets NFPA 85 safety standard MFT alarming with manual reset, first-out indication Optional enhanced alarming
More informationConnection of CES-AP to safety relay PNOZ s4.1 Content
Connection of CES-AP to safety relay PNOZ s4.1 Content Interlocking device according to EN 1088... 2 Components/modules used... 2 EUCHNER... 2 Other... 2 Functional description... 3 General... 3 Connections...
More informationConnection of CET4-AR to safety relay PNOZ s5
Connection of CET4-AR to safety relay PNOZ s5 Content Guard locking power on applied spring released according to EN ISO 14119 (open-circuit current principle)... 2 Components/modules used... 2 EUCHNER...
More informationHIPPS High Integrity Pressure Protection System
HIPPS High Integrity Pressure Protection System L&T Valves L&T Valves is a wholly owned subsidiary of Larsen & Toubro. Backed by a heritage of excellence that exceeds five decades, the company manufactures
More informationMachine Safety Sensing Control Products Automation Solutions
YOUR SINGLE SOURCE FOR Machine Safety Sensing Control Products Automation Solutions NEWEST GENERATION OF SAFETY & AUTOMATION RELAY INNOVATIVE SENSING SOLUTIONS INNOVATIVE & TRADITIONAL MACHINE SAFETY AUTOMATION
More informationDENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION IBAS LIGHTING CONTROL
PART 0 A/E INSTRUCTIONS 0.01 DESIGN REQUIREMENTS A. Minimum lighting control (base scope of work) shall include all corridors. The lighting in all the corridors shall be turned on (if not already on) if
More informationConnection of CET4-AR to safety relay PNOZ X3.10P
Connection of CET4-AR to safety relay PNOZ X3.10P Content Guard locking power on applied spring released according to EN ISO 14119 (open-circuit current principle)... 2 Components/modules used... 2 EUCHNER...
More informationSafety in system: Protection for man and machine Innovations 2016/2017
Safety in system: Protection for man and machine Innovations 2016/2017 Schmersal Safety Installation Systems The right solution for every application The new Schmersal Safety Installation System provides
More informationAxle Counter Az LE The Axle Counter System for small and mid-sized applications
www.thalesgroup.com Axle Counter Az LE The Axle Counter System for small and mid-sized applications Small, Strong, Cost-Efficient Az LE the latest Axle Counter System is completing Thales s Axle Counter
More informationAUTOMATION & ROBOTICS
AUTOMATION & ROBOTICS AUTOMATION & ROBOTICS www.valin.com www.valin.com MOTION CONTROL & AUTOMATION Valin is the smart systems solution provider that makes high technology possible. No matter what your
More informationEngineering Guideline. pac-carriers Type SIEMENS ET-200M Fail-safe signal modules
Engineering Guideline pac-carriers Type 9195 SIEMENS ET-200M Fail-safe signal modules pac-carrier Type 9195 2 Engineering Guideline/SIEMENS 19.05.2015 pac-carrier Type 9195 Integration of conventional
More informationThe Minor Servicing Exemption LOTO s Misunderstood Requirement
The Minor Servicing Exemption LOTO s Misunderstood Requirement Carlos Gallegos Assistant Area Director - Response Team Aurora Area Office gallegos.carlos@dol.gov Goals Review LOTO application Define employee
More informationProtective system controls, automatic burner control units, burner control units. Industrial & Commercial Thermal. 6 Edition 06.
Industrial & Commercial Thermal Protective system controls, automatic burner control units, burner control units Product brochure GB 6 Edition 06.15l FCU 500 Protective system controls FCU 500 Protective
More informationPublic Safety DAS Annunciator Panel
Public Safety DAS Annunciator Panel 120 VAC Models: 1221-A, 1221-B, 1221-C Revision D 91117 48 VDC Models: 1221-A-48, 1221-B-48, 1221-C-48 24 VDC Models: 1221A-24, 1221-B-24, 1221-C-24 CAUTION: (Read This
More informationTYPE APPROVAL CERTIFICATE
TYPE APPROVAL CERTIFICATE Certificate No: TAA0000120 Revision No: 1 This is to certify: That the Programmable Controller with type designation(s) Fail-safe Programmable Logic Controller and Fail-safe Modules
More informationNGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3 PRODUCT OVERVIEW
NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM Local configuration and monitoring with Raychem Touch 1500 touch screen display PRODUCT OVERVIEW The nvent RAYCHEM NGC-40 is a multipoint
More information7XG3120 ReyArc20 Arc Fault Monitor Relay Energy Management
Reyrolle Protection Devices 7XG3120 ReyArc20 Arc Fault Monitor Relay Energy Management 7XG3120 - Arc Fault Monitor Relay The over-current caused by an arc is, due to its resistance, lower than the over-current
More informationNGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3
NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM Local configuration and monitoring with Raychem Touch 1500 touch screen display PRODUCT OVERVIEW The Raychem NGC-40 is a multipoint electronic
More informationThe Next Generation Machine Protection System
ST100 SafeMax PROTECTION SYSTEM ST100 SafeMax The Next Generation Machine Protection System Welcome to the new world of turbine protection, where speed, torque, acceleration, creep, can now be combined
More informationPilz Safety Lockout System (PSLS)
Pilz Safety Lockout System (PSLS) An alternative isolation method for LOTO By Doug Sten, Safety Consultant, Pilz Automation Safety Objectives Challenges with manual, mechanical isolation disconnects Challenges
More informationAIS750 Series Alarm Annunciator User Manual (Ver. 2.3 / JUNE. 2014)
AIS750 Series Alarm Annunciator User Manual (Ver 23 / JUNE 2014) 3-350 John Street, Thornhill, tario L3T 5W6 Phone: 289 597 APEX (2739) Fax: 289 597 2200 Toll Free: 1 866 776 2943 Email: mail@annunciatorca
More informationLubrication cycle IP Enclosure Rating. 110 VAC, 220/230 VAC (50/60 Hz) Alarm Fault Relay Contacts. IP-55 (Liquid tight connector)
SMAC Controller Industrial Lubrication Systems Operation The SMAC Controller is a multi-purpose programmable controller used with industrial lubrication systems. Controller settings are saved whenever
More informationDRAFT 20 October 2014
Technical data MTL process alarm equipment EPS rev 8 Programmable alarm annunciator Modular construction from 1 to 256 alarm channels Multi-redundant design so there is no single point of failure Choice
More informationDependable Solutions for Gas Detection
Dependable Solutions for Gas Detection Combustibles/Flammables Standard & Exotic Toxics Oxygen Enrichment/Deficiency Introduction to Sensidyne Established in 1983 - acquired by Schauenburg GmbH in April
More informationPump Logic User Manual CB-1000 P/N ILK-CB1000-1
Pump Logic User Manual CB-1000 P/N ILK-CB1000-1 STATEMENT OF LIMITED WARRANTY The limited warranty applicable to this product is set forth in USFilter Control Systems standard terms of sale that are made
More informationEncontrará el manual de instrucciones actual en su idioma oficial de la UE en nuestra página de Internet
1 About this document... pages 1 to 8 Translation of the original operating instructions 1.1 Function This operating instructions manual provides all the information you need for the mounting, set-up and
More informationSafety in the process industry
Products Solutions Services Safety in the process industry Simply reliable Table of contents Endress+Hauser: At home in the process safety Smart devices and concepts for hazardous areas Introduction to
More informationReport to the Certificate
Report to the Certificate XEF 15 SIL 0039 rev.1 Monitoring System, TDSP Manufacturer: CEMB S.p.A. Via Risorgimento n.9 23826 Mandello del Lario (Lc) Italy Report No.: 22CEM-TECH-15-03 Revision 2.0 of January,
More informationSafety Instrumented Fire & Gas Systems
Safety Instrumented Fire & Gas Systems aesolutions Provides Full-Service Fire & Gas Engineering and Products The aesolutions FM-approved family of Fire & Gas safety systems ensures compliance with the
More informationYaskawa Electric America Training Café
Functional Safety Yaskawa Electric America Training Café Today s topic is Functional Safety Standards & Safe Disable Presenter is Joe Pottebaum Senior Applications Engineer To make this Café enjoyable
More informationSIL725 Safety Annunciator
SIL725 Safety Annunciar Configurable SIL2 Annunciar certified IEC61508 SIRA certified at safety integrity level SIL2 IEC61508 Modular construction from 1 128 alarm channels Multi-redundant design Choice
More information