CONTENTS LITHONIA EMERGENCY SYSTEMS

Size: px
Start display at page:

Download "CONTENTS LITHONIA EMERGENCY SYSTEMS"

Transcription

1 CONTENTS EXIT SIGNS Architectural Specifi cation General Purpose Specialty Accessories Contractor Select Stock EXIT-UNIT COMBOS General Purpose Contractor Select Stock EMERGENCY LIGHTING UNITS Architectural Specifi cation General Purpose Specialty Remote Fixtures & Accessories Contractor Select Stock FLUORESCENT BATTERY PACKS Contractor Select Stock Power Sentry Linear Fluorescent Power Sentry Compact Fluorescent CENTRAL INVERTER SYSTEMS GENERAL INFORMATION Performance Data Safety Codes Outdoor Emergency Lighting

2 EXIT SIGNS SOLO SOLO Oval Suitable for architectural applications where aesthetics and superior performance are required. Injection-molded acrylic panels, ultrasonically welded to eliminate visible hardware. optical design engineered to minimize light tresspasing. Chevron directional indicators. Long-life white LEDs feature very low energy consumption and rated life up to 25 years. Dual-voltage input capability (120/277V). Recessed mounting. Roughin section recessed into wall or ceiling for top, back or end mounting capability. Special wording available; consult factory. UL Listed. Meets UL924. Architectural Organically shaped features reduces visual disruption. Graphically enhanced letters and mirror background Emergency operation exits use maintenance-free nickel-cadmium battery and self-diagnostics standard. ORDERING INFORMATION Lead times will vary depending on options selected. Consult with your sales representative. Example: SOLO W 1 RMR LA SD Series Housing SOLO LED (blank) Nickel W White B Black BZ Bronze Number of faces Letter color Directional indicators Operation Mounting Options 1 Single 2 Double RMR Red on mirror GMR Green on mirror (blank) No chevrons LA Left 1 RA Right 1 LRA Left and right DA Double-face chevrons 2 (blank) Standard non-emergency SD Nickel-cadmium battery with self-diagnostics X2 Lamps wired on two separate circuits (blank) EM Ceiling or back End (blank) PNL Complete exit panel and rough-in section Panel assembly only ELECTRICAL APPLICATION DATA TYPE VOLTS FACES AMPS WATTS Standard LED Standard LED Standard LED Standard LED Emergency LED Emergency LED Emergency LED Emergency LED ELA SOLORIS ELA W SOLOEMK ACCESSORIES ORDER SEPARATELY SOLO rough-in section (supplied standard with fixture unless PNL suffix is specified) ships with mounting hardware only. Order ELA SOLO RIS if needed for rough-in phase of construction. SOLO end-mount kit (supplied standard with fixtures designated EM). Must specify color. 4-3/4 (12.1) 8-3/4 (22.2) 4-3/4 (12.1) 11-7/8 (30.2) 10-3/8 (26.4) 10-1/2 (26.7) 14-1/4 (36.2) Back Mount 4-3/4 (12.1) 14-1/4 (36.2) Ceiling Mount 3/8 (1.0) 15-1/2 (39.4) End Mount 12-7/8 (32.7) 3-5/8 (9.2) 3-1/8 (7.9) Rough-in Section 13-5/8 (34.6) 1 Single-face exits only. 2 Double-face exit only

3 Suitable for architectural applications where aesthetics and superior performance are required. Injection-molded acrylic panels, ultrasonically welded to eliminate visible hardware. Depth of molded letters increases toward bottom of panel for better, more uniform illumination. Chevron directional indicators. Long-life LEDs feature very low energy consumption and rated life up to 25 years. Emergency operation exits use maintenance-free nickelcadmium battery. Recessed mounting. Roughin section recessed into wall or ceiling for top, back or end mounting capability. Surface top-mount (TM) option available on nonemergency exits, and attaches directly to J-box. Can be used for pendant mounting. Special wording available; consult factory. UL Listed. Meets UL924. CSA or NOM Certified (see Options). Architectural LRP Precise Edge-Lit EXIT SIGNS ORDERING INFORMATION For shortest lead times, configure products using bolded options. Example: LRP 1 RC 120/277 EL N Series Housing LRP LED (blank) Brushed aluminum W White B Black BZ Bronze BS Brass CR Chrome Number of faces 1 Single 2 Double Letter color RW Red on white RC Red on clear 1 RMR Red on mirror 2 GW Green on white 3 GC Green on clear 1,3 GMR Green on mirror 2,3 Directional indicators Voltage Operation Mounting Options (blank) No chevrons LA Left 1 RA Right 1 LRA Left and right DA Double-face chevrons 2 120/277 Dual voltage 120/347 Dual voltage 4 (blank) EL N X2 LDC6 LDC12/48 Standard nonemergency Nickel-cadmium battery 3 Lamps wired on two separate circuits 3,5 6V DC input for LED lamp V DC input for LED lamp 4 (blank) Ceiling or back EM End TM Top 6 (blank) Complete exit panel and rough-in section PNL Panel assembly only CSA Meets Canadian standards NOM Meets Mexican standards FI Fire alarm interface 3 FA Flashing emergency operation and intermittent audible alarm 3, 7 ELECTRICAL APPLICATION DATA TYPE VOLTS FACES AMPS WATTS Standard LED Red Standard LED Red Standard LED Red Standard LED Red Emergency LED Red Emergency LED Red Emergency LED Red Emergency LED Red Standard LED Green Standard LED Green Standard LED Green Standard LED Green Emergency LED Green Emergency LED Green Emergency LED Green Emergency LED Green Shipping weight: 5 lbs (2.3 kg) 1-3/4 (4.4) 8 (20.3) 13-1/8 (33.3) 13-1/4 (33.7) Top Mount 2 (5.1) 1-3/4 (4.4) 8 (20.3) ACCESSORIES ORDER SEPARATELY LED ROUGH-IN SECTION 8 Standard ELA LCRIS 1 or 2 faces, red or green Standard ELA LRIS 120 X2 1 or 2 faces, 120V w/x2 option Standard ELA LRIS 277 X2 1 or 2 faces, 277V w/x2 option Emergency ELA R LRIS 120/277 EL N 1 face, red Emergency ELA R 2LRIS 120/277 EL N 2 faces, red Emergency ELA G LRIS 120/277 EL N 1 face, green Emergency ELA G 2LRIS 120/277 EL N 2 faces, green Pendant mounting (top mount only) 14-3/4 (37.5) 14-3/4 (37.5) 13-1/4 (33.7) Back Mount 13-1/2 (34.3) End Mount ELA US12 5-1/4 (13.3) 8 (20.3) 2 (5.1) 1-3/4 (4.4) 8 (20.3) 12" pendant kit with brushed aluminum canopy 4-1/2 (11.4) 13-1/8 (33.3) 13-1/4 (33.7) Ceiling Mount 3-1/8 (7.9) Rough-in Section 2 (5.1) 13-5/8 (34.6) 1 Single-face exits only. 2 Mirror background simulates clear for double-face option. 3 Not available with CSA. 4 Only available with CSA. Consult specification sheet for further information. 5 Must specify input voltage 120 or Non-emergency exits only. No rough-in section required. Not available with LDC6 or LDC12/48. 7 Only available with EL N. 8 Supplied standard with exit unless PNL suffix is specified. Order separately only if necessary for early installation. When ordering rough-in separately, all options must be included with rough-in nomenclature (example: ELA LCRIS 120/277 FI)

4 EXIT SIGNS EDG Surface-Mount Edge-Lit Suitable for applications requiring attractive edge-lit exit signage, universal installation and low energy consumption. Extruded aluminum or white finish lamp housing. Clear thermoplastic panels with precision outline engraved letters measuring 6" high with 3/4 " stroke. EDGNY and EDGRNY feature clear acrylic panels with letters measuring 8" high with 1" stroke and are New York City compliant. Mirrored separator panel to simulate clear background. (Standard on double-face.) Dual-input voltage capability (120/277V). Expected LED life of more than 10 years. Low energy consumption: less than five watts. Universal (top, end or back) mounting. Double face available with top or end mounting only (canopy provided). Specification EDGRNY is for recessed top mounting only. Universal directional indicators. Field selected and attached. UL Listed. Meets UL924. ORDERING INFORMATION For shortest lead times, configure products using bolded options. Example: EDG 1 R EL Series Housing Number of faces Letter color Operation EDG Surface mount LED edge-lit (blank) Aluminum 1 Single R Red (blank) Standard non-emergency EDGNY Surface mount LED edge-lit 8" letters W White 1 2 Double G Green 1 EL Nickel-cadmium battery EDGRNY Recess mount LED edge-lit 8" letters RMR Red, mirror 2 SD Self diagnostics (available with EL option only) 1 GMR Green, mirror 1,2 X2 Lamps wired on two separate circuits (available with green letters and AC operation only) 1 ELECTRICAL APPLICATION DATA TYPE VOLTS AMPS WATTS Standard LED Red 120 / / / 2.77 Standard LED Green 120 / / / 2.20 Emergency LED Red 120 / / / 2.20 Emergency LED Green 120 / / / 2.77 Standard LED Red (NY) 120 / / / 3.00 Emergency LED Red (NY) 120 / / / 3.00 Shipping weight 4 lbs (1.8 kg) 5-1/2 (14.0) 11-3/4 (29.8) 12-1/8 (30.8) Test Switch Pilot Light Emergency Only) 4-3/8 (11.1) 12-1/8 (30.8) 13-5/8 (34.6) 13-3/4 (34.9) EDG End Mount 13 (33.0) 13-3/4 (34.9) EDG Back Mount 3/8 (1.0) EDG Top Mount 13-1/4 (27.9) 10 (25.4) 3-3/8 (8.6) 3-3/8 (8.6) 13-1/4 (27.9) 15-1/8 (38.4) EDGNY 1-3/4 (4.4) 15-1/8 (38.4) 17-3/8 (44.1) EDGRNY 4-1/8 (10.5) 1 Not available on EDGNY and EDGRNY. 2 Available with EDG single-face only. Mirrored panel standard on double-face

5 Ideal for applications requiring attractive die-cast aluminum signage, superior illumination and low energy consumption. Solid, die-cast aluminum housing - smallest sign on the market. Standard finish is brushed aluminum face with matte black housing. Other finishes available. LENY features 8" high letters with 1" stroke and are New York City compliant. The self-diagnostic emergency signs comply with NFPA Life Safety Code and automatically test the battery once a month for five minutes and once every six months for 30 minutes. Completely concealed chevron directional indicator knockouts and mounting hardware. Long-life LEDs feature very low energy consumption and rated life up to 25 years. A non-emergency red LED exit consumes only.73 watts of electricity at 120V. LEDs provide uniform graphics illumination. Meets 3/4 " letter stroke requirements. Dual-voltage capability (120/277V). Emergency exits contain maintenance-free nickelcadmium battery and reliable, solid-state charging system. Universal (top, back or end) mounting. Double face available with top or end mounting only (canopy included). US Patent No. 5,954,423. UL Listed. Meets UL924. CSA or NOM Certified (see Options). Specification LE LRE Signature Die-Cast Aluminum EXIT SIGNS 1 ORDERING INFORMATION For shortest lead times, configure products using bolded options. Example: LE S W 1 R 120/277 EL N Series Face type Housing Number of faces 2 Letter color Voltage LE LED S Stencil 13 (blank) Brushed aluminum face and 1 Single R Red LRE LED recessed 1 matte black housing 2 Double 5 G Green 1,4 120/ /347 Dual voltage Dual voltage 4,7 LENY LED 8-inch letters 1,2,3 BZ Dark bronze 1,4 3 Single with extra faceplate and color W White panel for field conversion to double-face 6 B Matte black 1,4 Operation (blank) Standard non-emergency EL Nickel-cadmium battery 6 EL N Nickel-cadmium battery 1,5 EL N SD Nickel-cadmium battery with self-diagnostics 4,8 LDC6 6V DC input for LED lamps 4,5,7 LDC12/ V DC input for LED lamps 4,5,7 X2 Lamps wired on two separate circuits 1,4,9 Options CSA Meets Canadian standards 4 NOM Meets Mexican standards 4 PRIMARY CIRCUIT EMERGENCY CIRCUIT ELECTRICAL APPLICATION DATA TYPE VOLTS FACES AMPS WATTS Standard LED Red 120 1, Standard LED Red 277 1, Standard LED Red 347 1, Standard LED Green 120 1, Standard LED Green 277 1, Emergency LED Red 120 1, Emergency LED Red 277 1, Emergency LED Red 347 1, Emergency CSA LED Red 120 1, Emergency CSA LED Red 347 1, Emergency LED Green 120 1, Emergency LED Green 277 1, LDC6 6 1, LDC12/ , LDC12/ , LDC12/ , LDC12/ , ACCESSORIES ORDER SEPARATELY ELA WG1 Back-mount wireguard 4, 10 ELA B US12 12" pendant kit with black canopy ELA LEHO 120/277 N Remote-capable with black canopy; provides 90 minutes of 1,4, 10, W capacity for remote head 6 (15.2) 1-5/8 (40.1) 11-3/8 (28.9) 13 (33.0) LE End Mount Shipping weight: 5 lbs (2.3 kg) 13 (33.0) LRE Recessed Mount 7-7/8 (20.0) 9-1/2 (24.1) Shipping weight: 10 lbs (4.5 kg) 4 (10.2) 5-3/4 (14.4) 11-3/8 (28.9) LE Back Mount /8 (20.0) 4 (10.0) 4-1/2 (11.4) 1-1/4 (3.2) LE Top Mount 9-1/2 (24.1) 1 Not available with CSA. 2 LENY only available with single face with extra face plate and color panel (3). 3 LENY measures 12-3/4 (L) x 9 (H) x 2 (D). 4 Not available with LENY. 5 Not available with recessed exits. 6 Available with LENY only. 7 Only available with non-emergency CSA. 8 Must specify input voltage (120 or 347V) with CSA option. 9 Must specify input voltage (120 or 277V). 10 Add W for white canopy. 11 Canopy required for ELN SD, CSA or LDC option. (Measures 5-3/4" x 8" x 2-1/4".) 12 For use with emergency exits only. 13 Standard for LENY _ no specifiaction required

6 EXIT SIGNS LQC Quantum Die-Cast Aluminum Ideal for applications requiring general-purpose emergency lighting exit sign. Die-cast aluminum construction - compact housing. Brushed aluminum faceplate with matte black electrostatic polymeric trim. Clear lacquer finish on brushed face inhibits fingerprints and other surface contaminants. Also available in white housing and face. Fully overlapping light seal prevents light leaks. Universal direction chevron knockouts are concealed and easily removed. Provisions for conduit entry and pendant mounting. U.S. Patent No. 5,739,639. Other patents pending. Expected LED life of more than 10 years. Universal (top, end or back mounting). Completely concealed, easily removed mounting knockouts and hole plugs. No exposed hardware. Die-cast aluminum canopy provided. Faceplate accessory kit available for one-face to two-face field conversion. Dual-voltage input capability 120 or 277 VAC. Emergency models provided with testswitch, status indicator and a battery that automatically recharges when normal power is restored. Emergency models provided with maintenance-free, sealed Specification nickel-cadmium battery to provide 90 minutes of emergency power if necessary. UL Listed. Meets UL924. Damp location listing 50 to 104 F (10 to 40 C) standard. ORDERING INFORMATION For shortest lead times, configure products using bolded options. Example: LQC 1 R EL N Series Housing Number of faces Letter color Options LQC LED (blank) Matte black, brushed aluminum face W White 1 Single face 2 Double face R Red G Green (blank) AC only 120/277V EL N 120/277 VAC input with nickel-cadmium battery back-up ELECTRICAL APPLICATION DATA TYPE VOLTAGE INPUT WATTS MAXIMUM AMPS Standard LED Red Standard LED Red Standard LED Green Standard LED Green Emergency LED Red Emergency LED Red Emergency LED Green Emergency LED Green Shipping weight 4.5 lbs (2.0 kg) 5-3/4 (14.6) 8-1/4 (21.0) 8-1/4 (21.0) 4-3/4 (12.1) 8-3/4 (22.2) ELA WG1 ELA WGEXT ELA WGEXE ELA B US12 ELA LQCFPK ELA W LQCFPK ACCESSORIES ORDER SEPARATELY Back-mount wireguard Top-mount wireguard End-mount wireguard 12" pendant-mount kit with black canopy. To order white canopy, replace B with W in catalog number. To order 24" or 36" lengths, replace 12 with 24 or 36. Brushed/black faceplate kit with red and green sign panel for one-face to two-face field conversion White faceplate kit with red and green sign panel for one-face to two-face field conversion 11-3/4 (29.8) End Mount 11-3/4 (29.8) Back Mount 2 (5.1) Top Mount

7 Ideal for applications requiring attractive, quick- installation exit signs and low energy consumption. Precision-molded thermoplastic housing is impact- and scratch-resistant, corrosionproof and UV-stabilized to resist discoloration. Innovative snap-together design allows installation in less than three minutes. Long-life LEDs feature very low energy consumption and rated life up to 10 years. Consumes less than one watt of energy. Fully assembled single-face exit with optional extra faceplate for easy field conversion to double-face standard. Replaceable chevron directional indicator knockouts for choice of direction. Universal (top, end or back) mounting with canopy included. Automatic recharge after discharge. Conveniently located test switch and status indicator provide visual and manual means of monitoring system operation. The self-diagnostic emergency signs comply with NFPA Life Safety Code and automatically test the battery once a month for five minutes and once every six months for 30 minutes. U.S. Patent No. 5, 526, 251; 5, 611, 163; 5, 739, 639 and 5, 954, 423. Other patents pending. UL Listed. Meets UL924. UL damp location listing 50 to 104 F (10 C to 40 C) standard. NOM Certified (see Options). General Purpose LQM Quantum Thermoplastic EXIT SIGNS ORDERING INFORMATION For shortest lead times, configure products using bolded options. Example: LQM S W 3 R 120/277 EL N Series Face type Housing Number of faces Letter color Voltage Options LQM LED S Stencil (blank) Black W White 3 Single with extra faceplate and color panel for field conversion to double-face R Red G Green 120/277 Dual voltage 1 (blank) Standard non-emergency EL N Nickel-cadmium battery SD Self diagnostics 2 X2 Lamps wired on two separate circuits 3 NOM Meets Mexican standards 4 ELECTRICAL APPLICATION DATA TYPE VOLTS AMPS WATTS Standard LED Red Standard LED Red Standard LED Green Standard LED Green Emergency LED Red Emergency LED Red Emergency LED Green Emergency LED Green ACCESSORIES ORDER SEPARATELY ELA W US12 12" stem kit with white canopy 5 ELA WG1 Back-mount wireguard ELA WGEXT Top-mount wireguard ELA WGEXE End-mount wireguard Shipping weight 2.6 lbs (1.2 kg) 5-5/8 (14.3) 11-3/4 (29.8) End Mount 7-5/8 (19.4) 5-7/8 (14.9) 11-3/4 (29.8) Back Mount 3-7/8 (9.8) 7-5/8 (19.4) 4-1/2 (11.4) 2 (5.1) Top Mount 8-1/2 (21.6) 1 Some special voltages available. Consult factory. 2 Available with EL N operation only. 3 Available with AC operation only. 4 Available with stencil or panel faces in white housing and red letters only. 5 Replace W with B for black canopy

8 EXIT SIGNS LV Extreme All-Conditions Ideal for high-abuse, cold weather (down to -40 C with CW option) and wet location applications such as schools, security areas/prisons and parking garages. Durable, cast-aluminum construction. Rugged housing is.250" to.525" thick. Clear, UV-stable polycarbonate cover is.130" thick to prevent cracking or breaking. Secured with four stainless steel TORX T20 tamperproof screws with center pin. Completely concealed chevron directional indicator knockouts. Long-life LEDs feature very low energy consumption and a rated life up to 25 years. Emergency exits contain maintenance-free nickelcadmium battery and reliable, solid-state charging system. Dual-voltage input capability (120/277V). UM option offers conduit entry and top, end or back mounting. Double face available with top or end mounting only (canopy provided). Self-diagnostics option automatically tests battery once a month for five minutes and once every six months for 30 minutes. Specialty Vandal-resistant magnetic test switch and status indicator provide a safe, easy means of testing. U.S. Patent No. D383,501 and 5,611,163. UL Listed. Meets UL924. CSA or NOM Certified (see Options). 4X option is UL Listed, including wet location. ORDERING INFORMATION For shortest lead times, configure products using bolded options. Example: LV S W 1 R 120/277 UM EL N R Red 120/277 Dual voltage 1 (blank) Back mount 4 Series Face type Housing Number of faces Letter color Voltage Mounting LV LED S Stencil (blank) Black faceplate on black housing 1 Single W White on white 2 Double 2 G Green 1 120/347 Dual voltage 3,9 UM Universal mount 8 WB White on black BW Black on white AB Aluminum on black 1 AW Aluminum on white 1 Operation (blank) Standard non-emergency EL N Nickel-cadmium battery 5 EL N SD Nickel-cadmium battery with self-diagnostics 1 LDC6 6V DC input for LED lamp 3 LDC12/ V DC input for LED lamp 3 X2 Lamps wired on two separate circuits 1,6 Options (blank) None CW Cold weather and NEMA 4X wet location to -40 C 1,7,10 4X UL Listed for NEMA 4X for wet location 1 CSA Meets Canadian standards NOM Meets Mexican standards ELECTRICAL APPLICATION DATA 10 TYPE VOLTS FACES AMPS WATTS Standard LED Red / Green / /1.7 Standard LED Red / Green / /2.8 Standard LED Red / Green / /1.9 Standard LED Red / Green / /3.3 Emergency LED Red / Green / /2.2 Emergency LED Red / Green / /3.2 Emergency LED Red / Green / /2.5 Emergency LED Red / Green / /4.0 LED Standard (CSA) / Emergency (CSA) / /13.27 LED Standard (CSA) / Emergency (CSA) / /8.14 LED Standard (CSA) / Emergency (CSA) / /12.65 LED Standard (CSA) / Emergency (CSA) / /7.83 Shipping weight 11 lbs (5.0 kg) 6 (15.2) 13-7/8 (35.2) 15 (38.1) End Mount 8.5 (21.6) 8-3/4 (22.2) 4-3/8 (11.1) 13-7/8 (35.2) 4-3/4 (12.1) 9-1/2 (24.1) Back Mount 4 (10.2) 6 (15.2) 3 (7.6) Single Face 9-7/8 (24.9) 4-1/4 (10.8) Double Face Top Mount EMERGENCY CIRCUITS 3 TYPE VOLTS FACES AMPS WATTS LDC LDC LDC12/ LDC12/ LDC12/ LDC12/ LDC12/ LDC12/ LDC12/ LDC12/ ELA TPS T20 ACCESSORIES ORDER SEPARATELY TORX tamperproof bit for T20 center-pin screw 1 Not available with CSA option. 2 Available with universal mount only. 3 Only available with CSA option. 4 Not available on double face. 5 Must specify input voltage (120 or 347V) with CSA option. 6 Must specify input voltage (120 or 277V). UL listed as emergency lighting equipment. 7 Available with emergency exits only. 8 Universal mount standard with conduit entry (1/2"-14 UNC). 9 Only available with standard, non-emergency exit. 10 Add 24 input watts for CW battery heater option

9 Ideal for applications where electrical power cannot be provided. Tritium-filled gas tubes require no electrical input or external light source and are rated for 10-year luminous life (20-year life option available). Universal directional indicators and mounting (canopy included). Completely sealed housing. Suitable for wet locations. Tamperproof mounting hardware included. UL Listed. Meets UL924. Specialty D Self Luminous EXIT SIGNS ORDERING INFORMATION Lead times will vary depending on options selected. Consult with your sales representative. Example: D S W 1 R Series Face type Housing Number of faces Faceplate color Luminous life Options D Self luminous S Stencil (blank) Black 1 Single R Red (blank) Luminous life rating of 10 years VR Vandal shield 2,3,4 W White 2 Double G Green 20 Luminous life rating of 20 years AA Aluminum anodized frame 5 AL Aluminum 1 IF Institutional frame (21.6) 7-5/8 (19.4) 8-1/2 (21.6) Drawings are for dimensional detail only and may not represent actual mechanical configuration. Dimensions are shown in inches (centimeters) 14 (35.6) Single face Shipping weight: 1.5 lbs (0.7 kg) Plastic Housing Double face 3 lbs (1.4 kg) 1 (2.5) 2 (5.1) Plastic Housing 12-1/4 (31.1) Single face Shipping weight: 1.5 lbs (0.7 kg) Aluminum Housing Double face 3 lbs (1.4 kg) 1-1/2 (3.8) 2 (5.1) ALuminum Housing 1 Only available with AA option. 2 Only available in single face. 3 Only available with aluminum housing color. 4 Consult factory for dimensional details. 5 Available in all housing colors. Specialty LX is suitable for applications requiring heavy-duty steel exit signage such as a light industrial warehouse or manufacturing facility. LXNY and LHXNY are ideal for New York City applications where steel housing and 8" letter height are required. Heavy-gauge, die-formed steel housing. Impactresistant color panels. LXNY and LHXNY feature 8" high letters with 1" stroke and are New York City compliant. Knockout chevrons for choice of direction. LHXNY features three PAR36 style thermoplastic lamp heads. Long-life LEDs feature very low energy consumption and rated life up to 25 years. Dual-voltage capability (120/277V). Universal (top, end or back) mounting with canopy included. Back mounting only for LHXNY. UL Listed (standard). LX Titan LED R Red 120/277 Dual voltage 4 (blank) Standard non-emergency 3 ORDERING INFORMATION For shortest lead times, configure products using bolded options. Example: LX S W 1 R 120/277 EL N Series Face type Housing Number of faces Letter color Voltage Operation LX LED S Stencil 5 (blank) Matte black 1 1 Single 2 LXNY LED W White 3 Single with extra faceplate and color panel 3 G Green 1 EL N Nickel-cadmium battery 3 LHXNY LED exit/unit EL Nickel-cadmium battery 6 ELECTRICAL APPLICATION DATA TYPE VOLTS AMPS WATTS Standard LED Red 120 / / /.68 Standard LED Green 120 / / /.72 Emergency LED Red 120 / / /.92 Emergency LED Green 120 / / /.92 Standard LED Red (LXNY) 120 / / / 5.0 Emergency LED Red (LXNY) 120 / / / 5.0 Emergency LED Red (LHXNY) 120 / / / 14.3 mechanical configuration. Dimensions are shown in inches (centimeters) Shipping weight: 5 lbs (2.3 kg) 4-7/8 (12.4) 11-1/2 (29.2) 12-3/8 (31.4) End Mount 7-7/8 (20.0) 4-1/2 (11.4) 8-3/4 (22.2) 2-1/2 (6.4) Top Mount 5-3/4 (14.6) Back Mount 4 (10.0) 7-7/8 (20.0) 1 Not available with LXNY or LHXNY. 2 Not available with LXNY. 3 Not available with LHXNY. 4 Voltage not required in catalog number for LXNY or LHXNY. 5 Standard for LXNY and LHXNY - no specification required. 6 Only available with LXNY

10 EXIT SIGNS CUSTOM SIGNAGE Lithonia Lighting offers special signage in the Signature and Quantum families. Most special signage is available with red or green LED lighting. See below for special wording ordering guide. Specialty AREA OF REFUGE AREA OF RESCUE AREA OF RESCUE ASSISTANCE AREA OF RESCUE ASSISTANCE Signature Sign Quantum Sign Quantum Sign/Unit Combo Family Face type Housing LE Signature die-cast aluminum sign LQM LHQM Quantum thermoplastic sign 1 Quantum thermoplastic sign/unit combo 1 P Panel (blank) Matte black, brushed aluminum base W White SW01 BEAM IN USE IN USE ON AIR Number of faces 1 Single face 2 Double face 3 Single with extra faceplate and color panel 2 DARKROOM IN USE LASER IN USE ROOM IN USE EXIT MAGNET IN USE SALIDA Letter color Voltage Operation 3 Special wording R Red G Green SW02 SW03 SW04 120/277 Dual voltage (blank) AC only EL N Nickelcadmium battery EXIT SW05 SW06 SW07 SW08 NO EXIT SW09 SW010 SW011 SW012 X-RAY IN USE SW013 SW014 SW015 SW016 ORDERING INFORMATION For shortest lead times, configure products using bolded options. Example: LE P W I R 120/277 EL N SW02 SW01 AREA OF REFUGE SW02 AREA OF RESCUE SW03 AREA OF RESCUE ASSISTANCE SW04 AREA OF RESCUE ASSISTANCE with access pictogram SW05 BEAM IN USE 4 SW06 DARKROOM IN USE 4 SW07 EXIT Arabic/English SW08 EXIT with access pictogram SW09 IN USE 4 SW10 LASER IN USE 4 SW11 MAGNET IN USE 4 SW12 NO EXIT SW13 ON AIR 4 SW14 ROOM IN USE 4 SW15 SALIDA 5 SW16 X-RAY IN USE 4 1 Only available in white housing. 2 Only available with LQM and LHQM family. 3 Not applicable to LHQM family. 4 Not available with LHQM family or EL N operation. 5 Only available in red letter color. EXIT ACCESSORIES WIREGUARDS ELA WG1 Back-mount wireguard (shown) 13-1/2" H x 15" W x 6" D ELA WGEXT Top-mount wireguard 14" W x 11" H x 6-3/4" D ELA WGEXE End-mount wireguard 15" W x 11" H x 4-3/4" D ELA WG3 Back mount for LHQM combo 13-1/2" H x 30" W x 6" D 1 Stem color is brushed aluminum. Standard canopy ELA US12 STEM KITS 1 Signature LE standard or emergency, Precise LRP with TM option, Quantum, Titan LED ELA WG1 Accessories color is brushed aluminum. To order white or black canopy, add W or B to catalog number. For other lengths, replace 12 with appropriate stem length in inches. Example: ELA W US

11 Suitable for applications requiring quick installation of both exit sign and unit equipment. Attractive 10" tall, streamlined design is great for above-the-door applications and other tight fits. Precision-molded thermoplastic housing is impactresistant, corrosion-proof and UV-stabalized to resist discoloration. Quick-Mount installation. Innovative, snap-together design allows for installation in less than three minutes. Factory assembled and prewired. Replaceable chevron directional indicator knockouts for choice of direction. Side-mount lamp heads reduce overall height, allowing for easy fit over doorways. Long-life LEDs feature very low energy consumption and rated life up to 10 years. Dual-voltage input standard (120/277V). Sealed, maintenance-free, lead-calcium battery standard. Nickel-cadmium battery optional. Two 5.4W wedge-based krypton lamps offer 32% more light output than standard incandescent lamps. Patented MR24, multifaceted reflector significantly improves photometric performance; % more light delivered to the path of egress. Universal (top, end or back) mounting with canopy included. Optional high-output battery (HO) to power a remote head or exit. U.S. Patent No. 5, 611, 163; 5, 646, 502; 5, 526, 251; 5, 797, 673 and D379, 373. Other patents pending. UL Listed. Meets UL924. UL damp location listed (50 to 104 F (10 to 40 C) standard. NOM Certified (see Options). General Purpose LHQM Quantum Thermoplastic EXIT-UNIT COMBOS ORDERING INFORMATION For shortest lead times, configure products using bolded options. Example: LHQM S W 3 R Series Face type Housing Number of faces Letter color Options LHQM LED exit/ S Stencil (blank) Black 3 Single with extra faceplate and color panel for R Red N Nickel-cadmium battery 1 unit W White field conversion to double-face G Green HO High-output lead-calcium battery HO R0 High-output lead-calcium battery, less lamp heads NOM Meets Mexican standards 2 REMOTE OUTPUT CAPACITY FAMILY STANDARD COMBO COMBO/NI-CAD BATTERY (N) COMBO/HIGH-OUTPUT BATTERY (HO) COMBO/NO HEADS (R0) AND HIGH-OUTPUT BATTERY (HO) LHQM NA NA 12W 24W ELECTRICAL APPLICATION DATA AC LAMP AC INPUT OUTPUT WATTS OUTPUT VOLTS VOLTS AMPS WATTS 1-1/2 HRS 2 HRS 3 HRS STANDARD LAMP WATTS LED Red/Green MR24 K LED Red/Green (HO) MR24 K ELA MR24 K0606 ELA MR24 K0906 ELA NX H0606 ELA WG3 ACCESSORIES ORDER SEPARATELY Compact MR24 remote head (6W, 6V krypton lamp) Compact MR24 remote head (9W, 6V krypton lamp) NEMA 4X sealed-beam remote fixture (6W, 6V halogen lamp) Wireguard (back mount only) Shipping weight 7.36 lbs (3.3 kg) 21-1/4 (54.0) 9-7/8 (25.1) 4-7/8 (12.4) 1 Not available with HO. 2 Available with stencil on panel faces in white housing and red letters only

12 EMERGENCY LIGHTING UNITS AFN Affinity Provides a minimum of 90 minutes illumination for the rated wattage upon loss of AC power. Ideal for applications requiring attractive unit equipment. Compact, low-profile, architectural design with die-cast aluminum housing. Available finishes are texturized polyester powder coat paint in nickel white, black and dark bronze. The self-diagnostic emergency units comply with NFPA Life Safety Code and automatically test the battery once a month for five minutes and once every six months for 30 minutes. U.S. Patent No. D468,046. Standard optics provided with two 6W wedge-base xenon lamps offer 55% more light output than standard incandescent lamps. Forward throw (FWD) option optics provided with two high-brightness white LEDs projecting a forward throw beam of light. Patented reflector/refractor design features superior vac-metalized, die-casted reflectors and multifaceted, highly transmissive refractors that significantly improve photometrics. Maintenance-free leadcalcium battery (standard). Nickel-cadmium optional. Dual-voltage input capability (120/277V). Low-profile, integrated test switch/pilot light located below the lens. Architectural Rigid conduit entry provision on top of the unit. Remote version available for exterior use. Ideal for exit discharge applications. UL Listed. Meets UL 924. Wet location (EXT) listed. Damp location (PREM, EXT) listed. Cold weather (EXT) listed. Meets NFPA 101, NFPA 70-NEC and OSHA illumination standards. ORDERING INFORMATION For shortest lead times, configure products using bolded options. Example: AFN W EXT Series Voltage Finish Options AFN (blank) 120/277V W White (blank) Lead-calcium battery B Black PREM Nickel-cadmium battery, self-diagnostics and damp location 32 to 122 F (0 to 50 C) BN Brushed nickel EXT High-temperature nickel-cadmium battery listed from 0 to 122 F (-18 to 50 C), time delay, DB Dark bronze 1 self-diagnostics, damp and wet location FWD Forward throw optics ELECTRICAL APPLICATION DATA TYPE AC INPUT OUTPUT VOLTS OUTPUT WATTS VOLTS AMPS WATTS 1-1/2 HRS AFN AFN AFN PREM AFN PREM AFN EXT AFN EXT /2 (24.1) 6-1/2 (16.5) 2-3/4 (7.0) Weight: 3.5 lbs (1.6 kg) 1 Dark bronze can only be ordered with EXT. This finish is not available on other units. For application guidelines and fixture performance data, see page

13 Provides 90 minutes of illumination for the rated wattage upon the loss of AC power. Ideal for applications that require ensconced emergency lighting in wall or ceiling. Trim and door housing panels are finished in durable white textured powder coated paint. Can be wallpapered or fieldpainted. Trim and panel doors lay flush with mounting surface. No exposed hardware. Low-profile recessed test switch and status indicator configuration minimizes exposed interfaces. Rugged, 22-gauge galvanized steel box with three 3/4" knockouts. Galvanized bar hangers span up to 30" on center. Two MR16 halogen 12W to 75W lamps are fully adjustable to meet aiming requirements. Lamps are ensconced until activated in the emergency mode. Sealed, maintenance-free lead-calcium battery with capacity of 24W to 150W for 90 minutes of emergency operation. Optional nickelcadmium battery. Low-voltage disconnect prevents excessive deep discharge that can permanently damage the battery. Dual-voltage input capability (120/277V). Precisioncontrolled motor and cam system ensures reliable extraction and retraction of light sources. Single, multichromatic LED indicator to display two-state charging, test activation and four-state diagnostic status. Standard self-diagnostic feature tests the unit for 30 minutes every 28 days without turning lamps on. Provided with an IR receiver for remote testing. Requires the ELA RTVEL remote transmitter (see Accessories). Selectable 30-second or 90-minute manual testing. UL Listed. Meets UL924. Architectural VEL Velare EMERGENCY LIGHTING UNITS ORDERING INFORMATION Lead times will vary depending on options selected. Consult with your sales representative. Series Lamp type 3 Options VEL V, 24W H W/12V halogen MR16 (blank) Lead calcium battery VEL V, 40W H W/12V halogen MR16 N Maintenance-free nickel-cadmium battery VEL V, 70W 1 H W/12V halogen MR16 TD Time delay VEL V, 100W 2 H W/12V halogen MR16 LRIS Less rough-in section 4 VEL V, 150W 2 H W/12V halogen MR16 Example: VEL1270 H3512 N ELECTRICAL APPLICATION DATA TYPE AC INPUT OUTPUT VOLTS OUTPUT WATTS VOLTS AMPS WATTS 1-1/2 HRS VEL VEL VEL VEL VEL VEL VEL VEL VEL VEL /2 (36.8) 7-5/8 (19.4) ACCESSORIES ORDER SEPARATELY ELA RTVEL Remote transmitter with selectable 30-second or 90-minute testing 5 ELA VEL RIS VEL rough-in section (supplied standard with fixture unless LRIS suffix is specified) ships with mounting hardware only; order ELA VEL RIS if needed for rough-in phase of construction WEIGHT AND DIMENSIONS VEL1224 (12V,24W) 20lbs VEL1240 (12V,40W) 20lbs VEL1270 (12V,70W) 26lbs VEL12100 (12V,100W) 26lbs VEL12150 (12V,150W) 32lbs ROUGH-IN OPENING 13-1/2 (341) X6-3/4 (170) OVERLAP TRIM 14-7/16 (365) X7-5/8 (193) 1 Not available with H1212 lamps. 2 Not available with H1212 or H2012 lamps. 3 Two lamps provided. Total lamp load cannot exceed the fixture capacity rating. 4 VEL rough-in section ships standard with fixture unless LRIS suffix is specified. Requires ELA VEL RIS accessory for installation. 5 Minimum one per job required. For application guidelines and fixture performance data, see page

14 EMERGENCY LIGHTING UNITS ELSQ Series ELSQ 6V, self-contained ELSQM 6V, 20W Provides a minimum of 90 minutes of illumination for the rated wattage upon loss of AC power. Ideal for applications requiring unobtrusive emergency lighting. Available surface, semi-recessed or recessed. Options Maintenance-free leadcalcium (standard) or nickelcadmium (optional) battery. Dual-voltage input capability (120/277V). 2L Two 8W lamps with Lexan lens and high-charge indicator (ELSQM only) 1 LEX Lexan lens (standard with 2L option) N Maintenance-free nickel-cadmium battery 1 Push-to-test button and "ready" light behind lens. One 10W or two 8W (with 2L option) halogen lamps provide high lumen output. UL Listed. Meets UL924. Specification ORDERING INFORMATION For shortest lead times, configure products using bolded options. Example: ELSQ ELECTRICAL APPLICATION DATA TYPE AC INPUT OUTPUT OUTPUT WATTS VOLTS AMPS WATTS VOLTS 1-1/2 HRS 2 HRS 3 HRS ELSQ ELSQ ELSQM ELSQM ACCESSORIES ORDER SEPARATELY ELA SRK Semi-recessed kit ELA FRK Fully-recessed kit ELA SQR 6V 6V, 10W halogen ELA SQR 12V 12V, 12W halogen 10-3/8 (26.4) 10-3/8 (26.4) ELSQ ELSQM Weight: 5 lbs (2.3 kg) 7 lbs (3.2 kg) 3-1/2 (8.9) 1 2L option is UL Listed for a two-hour run time. Not available with nickel-cadmium battery. ELCC Provides a minimum of 90 minutes of illumination for 12W upon loss of AC power. Designed for environments requiring decorative emergency lighting fixtures. Black 16-gauge steel backplate and housing. Contemporary white cylinder shroud with UV-stabilized high-temperature plastic optical lens. Sturdy, adjustable castaluminum swivel. One 8W (single) or two 6W (twin) halogen wedgebase lamps. Wall or ceiling mount. Dual-voltage input capability (120/277V). Sealed, maintenance-free lead-calcium battery provides 12W rated capacity. UL Listed. Meets UL924. Specification ORDERING INFORMATION For shortest lead times, configure products using bolded options. Example: ELCC Series Options ELCC (blank) Single lamp head T Twin lamp heads ELECTRICAL APPLICATION DATA TYPE AC INPUT OUTPUT WATTS OUTPUT VOLTS VOLTS AMPS WATTS 1-1/2HRS ELCC/ELCC T ELCC/ELCC T /2 (16.5) 13 (33.0) 6-1/2 (16.5) Single Head Weight: 9 lbs (4.1 kg) 13-1/4 (33.7) 13 (33.0) Twin Heads Weight: 14 lbs (6.6 kg)

15 Provides a minimum of 90 minutes of illumination for the rated wattage upon loss of AC power. Ideal for applications that require attractive unit equipment or when wall mounting is undesirable. Series ELR2 6V, 16W ELR2P 6V, 24W 1 ELR4 12V, 50W Heavy-duty recessed housing suitable for use in air-handling plenums. PAR36 lamp heads standard. Sealed, maintenance-free battery (lead-calcium standard, Options TD Integral time delay (18 minutes) 2,3 AM Ammeter 2 VM Voltmeter 2 H Two 8W halogen lamp heads nickel-cadmium optional) provides capacity for 90 minutes of emergency illumination. Dual-voltage input capability (120/277V). Sturdy T-bar clips secure unit to grid members. Adjustable bar hangers for easy mounting in walls and exposed or concealed suspended ceilings. UL Listed. Meets UL924. N1812 Two 18W, 12V incandescent lamp heads 3 N2512 Two 25W, 12V incandescent lamp heads 3 H1212 Two 12W, 12V halogen lamps 3 Specification ELR ORDERING INFORMATION For shortest lead times, configure products using bolded options. Example: ELR2 R0 Less lamp heads N Maintenance-free nickel-cadmium batteries 4 SD Self diagnostics EMERGENCY LIGHTING UNITS ELECTRICAL APPLICATION DATA AC INPUT OUTPUT OUTPUT WATTS VOLTS AMPS WATTS VOLTS 1-1/2 HRS 2 HRS 3 HRS 4 HRS ELR ELR ELR2P N ELR2P N ELR ELR Provides a minimum of 90 minutes of illumination for the rated wattage upon loss of AC power. Ideal for applications requiring unobtrusive emergency lighting. Matte white, baked enamel finish. All-metal housing and gimbal assembly. High-output, 8W halogen lamp. Lamp adjusts in two planes to 26. Dual-voltage input capability (120/277V). Low-profile pilot light and test switch. Approved for use in airhandling plenums. 12 (30.5) 12 (30.5) ELR2 Weight: 16 lbs (7.3 kg) Maintenance-free leadcalcium battery. Mounts in 6" diameter opening. UL Listed. Meets UL /8 (14.9) ELR lbs (10.2 kg) 1 Available with nickel-cadmium battery only. 2 Choice of two. Not available with AM, VM and TD on one unit. 3 ELR4 only. 4 Not available with ELR4. For additional lamp heads, remote fixtures, options and accessories, see pages For application guidelines and fixture performance data, see page 476. Specification ELRG ORDERING INFORMATION For shortest lead times, configure products using bolded options. Example: ELRG Series ELRG 6V, self-contained recessed gimbal ELECTRICAL APPLICATION DATA TYPE AC INPUT VOLTS AMPS WATTS ELRG ELRG /2 (21.6) 7-3/4 (19.7) 6-1/2 (16.5) 3-1/2 (8.9) 10-1/4 (26.0) 7 14 to 24 (17.8) (35.6 to 61.0)

16 EMERGENCY LIGHTING UNITS ELM ELM2 Quantum Thermoplastic Provides a minimum of 90 minutes of illumination for the rated wattage upon loss of AC power. Ideal for applications requiring attractive unit equipment with quick installation. White, compact, low-profile contemporary design with high-impact thermoplastic housing that is impactresistant, corrosion-proof and UV-stable to resist discoloration from artificial light sources or sunlight. Maintenance-free leadcalcium battery. Two 5.4W wedge-based krypton lamps offer 32 % more light output than standard incandescent lamps. Patented MR24, multifaceted reflector (ELM2) significantly improves photometric performance; % more light delivered to the path of egress. Dual-voltage input capability (120/277V). Edge connectors on printed circuit board ensure long-term durability. Unique track-and-swivel design permits full range of lamp head adjustment (ELM2). Universal J-box mounting pattern. Tool-less access for maintenance. Flexible conduit entry provision on top of the unit. Quick-Mount snap-together construction permits installation in three easy steps in less than three minutes.wall or ceiling mounted. UL Listed. Meets UL924. NOM Certified (see Options). General Purpose ORDERING INFORMATION For shortest lead times, configure products using bolded options. Example: ELM2 Series ELM 6V, 12W ELM2 6V, 12W Options SD Self diagnostics 1 B Black housing CSR 6' cordset attached 2 NOM Meets Mexican Standards 1 DL Damp location 50 to 104 F (10 to 40 C) ELECTRICAL APPLICATION DATA TYPE AC INPUT OUTPUT OUTPUT WATTS VOLTS AMPS WATTS VOLTS 1-1/2 HRS 2 HRS ELM/ELM ELM/ELM (12.7) 5 (12.7) ELA VS ELA WGST ACCESSORIES ORDER SEPARATELY Polycarbonate vandal shield Wireguard 11-1/2 (29.2) Weight: 3.0 lbs (1.4 kg) ELM 3-3/4 (9.5) 12-1/2 (31.8) Weight: 4.0 lbs (1.8 kg) ELM2 3-3/4 (9.5) 1 Available on ELM2 only. 2 Available on ELM 120V only. For application guidelines and fixture performance data, see page

17 Provides a minimum of 90 minutes of illumination for the rated wattage upon loss of AC power. Ideal for applications requiring attractive unit equipment with quick installation. White, compact, low-profile contemporary design with high-impact thermoplastic housing that is impactresistant, corrosion-proof and UV-stable to resist discoloration from artificial light sources or sunlight. Maintenance-free leadcalcium battery (standard). Two 9W wedge-based krypton lamps offer 48% more light output than standard incandescent lamps. Patented MR24, multifaceted reflector significantly improves photometric performance; % more light delivered to the path of egress. Universal voltage input capability (120 through 277V, 50 or 60Hz). Unique track-and-swivel design permits full range of lamp head adjustment. Universal J-box mounting pattern. Tool-less access for maintenance. Flexible conduit entry provision on top of the unit. Patent-pending Quick-Mount features simplify installation. Wall or ceiling bracket included as a standard feature. Quantum Series ELM6-12 will power a variety of remote devices up to rated wattage of fixture. UL Listed. Meets UL924. NOM Certified (see Options). General Purpose ELM 6-12 Quantum Thermoplastic EMERGENCY LIGHTING UNITS ORDERING INFORMATION For shortest lead times, configure products using bolded options. Example: ELM654 Series Lamp type Options ELM618 6V, 18W 6V M24 composite SD Self diagnostics 5 ELM627 6V, 27W (blank) 9W/6V krypton 1 B Black housing 6 ELM654 6V, 54W H W/6V halogen 2 N Maintenance-free ni-cad battery 7 ELM V, 54W H W/6V halogen 3 TD Time delay 5 ELM V, 72W 12V MR24 composite 4 RT Remote test capability. Remote tester sold as an accessory. 8 (blank) 9W/12V krypton R0 Less heads 9 H W/12V halogen DL Damp location 50 to 104 F (10 to 40 C) 7,10 H W/12V halogen NOM Meets Mexican Standards 11 ELECTRICAL APPLICATION DATA TYPE AC INPUT OUTPUT OUTPUT WATTS VOLTS AMPS WATTS VOLTS 1-1/2 HRS 2 HRS 3 HRS 4 HRS ELM ELM ELM ELM ELM ELM ELM ELM ELM ELM ELA LRT ELA VS2 ELA WG2M ELA MR24 ELA MR24 K0606 ELA MR24 K0906 ELA MR24 H1206 ELA MR24 K0912 ELA MR24 H1212 ELA MR24 H2006 ELA MR24 H2012 ELP UM085 ACCESSORIES ORDER SEPARATELY Remote tester (laser) Polycarbonate vandal shield (1/8" thick) Wireguard Compact MR24 remote lamp head (5.4W, 6V krypton) (9W, 6V krypton) (12W, 6V halogen) (9W, 12V krypton) (12W, 12V halogen) (20W, 6V halogen) (20W, 12V halogen) White lamp hole plugs (includes two) 12-3/4 (32.4) 7 (17.8) ELM654 ELM1254 ELM618 ELM627 ELM1272 Depth : 4-3/4 (12.1) 4-3/4 (12.1) 5-7/8 (14.9) Weight: 6.8 lbs (3.1 kg) 8.0 lbs (3.6 kg) 13.0 lbs (5.9 kg) D 1 Available on ELM618, ELM627 and ELM 654 only. 2 Available on ELM627 and ELM654 only. 3 Available on ELM654 only. 4 Available on ELM1254 and ELM1272 only. 5 When ordering ELM618 and ELM1254, SD and TD must be ordered with the N option. 6 Available on ELM627 and ELM1272 only. 7 Available on ELM618, ELM627 and ELM1254 only. 8 RT not available with SD. When ordering RT, an ELA LRT needs to be ordered separately. 9 Not available with any other options. 10 Damp location listed from 10 to 40 C (50 to 104 F) except ELM618N, ELM627N and ELM1254N which are listed from 15 to 32 C (60 to 90 F). 11 NOM available with ELM618 and ELM1254 only (not available with any other option). For additional lamp heads, remote fixtures, options and accessories, see pages For application guidelines and fixture performance data, see page

18 EMERGENCY LIGHTING UNITS IND Indura Industrial Provides a minimum of 90 minutes of illumination for the rated wattage upon loss of AC power. Unique, innovative design for a variety of light and heavy industrial applications and heavy commercial environments. Superiorperformance lamp heads are ideally suited for higher mounting heights. Perfect for pole and column mounting. Rugged,.140" thick, injection-molded thermoplastic. Vertical orientation is designed especially for pole or column mounting. Also suitable for wall and I-beam mounting. Ceiling and pendant mounting, with accessory equipment, available on selected models. Easy-mount installation with one galvanized, 12-gauge steel mounting bracket shipped standard. Conduit entry points are located on top and both sides of the unit. Maintenance is made easy by tool-less re-lamp, single tool entry, hinging front cover, printed circuit board mounting shelf and battery belt. Non sealed-beam lamps feature unique field-adjustable beam spread. Sealed maintenance-free, lead-calcium battery with wattage capacities from W for 90 minutes of emergency operation. Available in 6V, 12V and 24V. Dual voltage input capability (120/277V). U.S. Patent Specialty numbers. D419,097; 6,135,624 and 6,193,395. UL Listed. Meets UL924. Damp location listing. Cold weather (ULT) listing. NFPA 101, NEC and OSHA illumination standards. ORDERING INFORMATION For shortest lead times, configure products using bolded options. Example: IND1254 H2012 SEL Series Housing Lamp type 1 Options 6V IND618 18W IND654 54W IND W 12V IND W IND W IND W IND W IND W IND W 24V IND W IND W (blank) W Navy back, gray front White 6V (blank) H1206 H V (blank) H1212 9W/6V krypton 12W/6V halogen 20W/6V halogen 9W/12V krypton 12W/12V halogen H W/12V halogen H3512S 35W/12V halogen-sealed beam H5012S 50W/12V halogen-sealed beam 24V (blank) 18W/24V incand. H W/24V halogen N5024S 50W/24V incand.- sealed beam (blank) Damp location 50 to 103 F (10 to 40 C); except IND6100 and IND24450, which are listed 60 to 90 F (15-32 C). XTRA Extra package features remote test, time delay and damp location 50 to 104 F (10 to 40 C) 2 SEL Select package features self diagnostics, time delay, audible failure indication and damp location 50 to 104 F (10 to 40 C) PREM Premium package features high-temperature ni-cad battery (IND618 and IND1236 only) or high-ambient lead-calcium battery (IND12100 only), self diagnostics, time delay, audible failure indication and damp location; UL Listed for 32 to 131 F (0 to 55 C) 3, 4 ULT Ultimate package features heater, thermostat, battery blanket with hightemperature ni-cad battery (IND618 and IND1236 only) or high-ambient leadcalcium battery (IND12100 only), self diagnostics, time delay, audible failure indication and damp location 4, 5 ELECTRICAL APPLICATION DATA TYPE AC INPUT 6 OUTPUT OUTPUT WATTS VOLTS AMPS WATTS VOLTS 1-1/2 HRS 2 HRS 3 HRS 4 HRS IND / / / / 6 18 / / / 9 6 / 6 IND / / / / 6 54 / / / / 20 IND / / / / / / / / 37 IND / / / / / / / / 13 IND / / / / / / / / 20 IND / / / / / / / / 37 IND / / / / / / / / 56 IND / / / / / / / / 112 IND / / / / / / / / 168 IND / / / / / / / / 37 IND / / / / / / / / 168 ELA RTT ELA WG2M ELA BS ELA IND R3 ELA IND PM ELA IND CM1 ELA IND CM2 ELA IND CM3 ELA IND RH3 ELA WGLG ACCESSORIES ORDER SEPARATELY Remote transmitter Small wireguard Banding strap Pre-pack to install third head (does not include remote head) Pendant-mount kit 7 (small housing only) Ceiling-mount kit for IND618 Ceiling-mount kit for IND654/1236/1254 Ceiling-mount kit for IND6100 Remote head bracket for surface mount J-boxes Large wireguard 18 (45.7) 16 (40.6) 13-1/4 (33.7) Large Housing 160W PREM or ULT (150W - 450W) 8 (20.3) 12 (30.5) 12-1/2 (31.8) Small Housing (18W-100W) 9 (22.8) 3/8 (1.0) 8-3/8 (21.3) 1 (2.5) 2-1/4 (5.5) 1/4 (0.6) 2-1/4 (5.7) 2-3/4 (7.0) Universal Mounting Bracket 3/4 (1.9) 8 (20.3) 1 All models provided with two lamp heads. 2 Must order a remote transmitter (ELA RTT). One per job required. 3 Only available on IND618, IND1236 and IND IND12100 PREM and IND12100 ULT come in a larger housing size. 5 UL Listed for -40 to 55 C (-40 to 131 F). 6 Add 0.3 amps, 31watts for models with ULT option. 7 ELA IND PM accessory cannot be used with the IND PREM or IND12100 ULT.. For additional lamp heads, remote fixtures, options and accessories, see pages For application guidelines and fixture performance data, see pages 477 and

19 Provides a minimum of 90 minutes of illumination for the rated wattage upon loss of AC power. Unique design for heavy and demanding industrial applications such as manufacturing plants, refineries, chemical plants, wastewater treatment facilities, food-processing facilities, breweries, loading docks and other applications subject to hosedown or industrial conditions. Superior-performance lamp heads are ideally suited for higher mounting heights. Perfect for pole and column mounting. Rugged, heavy-duty polycarbonate housing is sealed, gasketed and corrosion-resistant. Vertical orientation - designed especially for pole or column mounting. Also suitable for wall and I-beam mounting. Easy-mount installation with one epoxy-coated galvanized, 12-gauge steel mounting bracket shipped standard. Conduit entry points are located on both sides of the unit. Maintenance is made easy by tool-less re-lamp, single tool entry, hinging front cover, printed circuit board mounting shelf and battery belt. Non-sealed-beam lamps feature unique field-adjustable beam spread. Sealed maintenance-free, lead-calcium battery with wattage capacities from 18W to 125W for 90 minutes of emergency operation. Available in 6V, 12V and 24V. Dual-voltage input capability (120/277V). U.S. Patent No. D419,097; 6,135,624 and 6,193,395. UL Listed. Meets UL924. Cold weather (ULT) listing. NFPA 101, NEC and OSHA illumination standards. NEMA 4; 4X Rated. IP66 and NSF listed. Specialty INDX Indura 4X EMERGENCY LIGHTING UNITS ORDERING INFORMATION For shortest lead times, configure products using bolded options. Example: INDX1236 ULT Series Housing Lamp type 2 Options 6V INDX618 18W INDX654 54W INDX W 12V INDX W INDX W INDX W 1 INDX W 24V INDX W (blank) Gray W White 6V (blank) H1206 H V (blank) H1212 9W/6V krypton 12W/6V halogen 20W/6V halogen 9W/12V krypton 12W/12V halogen H W/12V halogen H3512S 35W/12V halogen sealed-beam H5012S 50W/12V halogen sealed-beam 24V (blank) 18W/24V incandescent H W/24V halogen N5024S 50W/24V incandescent sealed-beam (blank) UL listed to 4X standards. XTRA Extra package features remote test and time delay; UL Listed for 50 to 104 F (10 to 40 C) 3 SEL Select package features self diagnostics, time delay and audible failure indicator; UL Listed for 50 to 104 F (10 to 40 C) PREM Premium package features high-temperature ni-cad battery (INDX618 or INDX1236 only) or high-ambient lead-calcium battery (INDX12100 only), self diagnostics, time delay and audible failure indication; UL Listed for 32 to 131 F (0 to 55 C) ULT Ultimate package features heater, thermostat, battery blanket with hightemperature ni-cad battery (INDX618 or INDX1236 only) or high-ambient lead-calcium battery (INDX12100 only), self diagnostics, time delay and audible failure indication 4,5 ELECTRICAL APPLICATION DATA TYPE AC INPUT 6 OUTPUT OUTPUT WATTS VOLTS AMPS WATTS VOLTS 1-1/2 HRS 2 HRS 3 HRS 4 HRS INDX / / / / 6 18 / / / 9 6 / 6 INDX / / / / 6 54 / / / / 20 INDX / / / / / / / / 37.5 INDX / / / / / / / / 13 INDX / / / / / / / / 20 INDX / / / / / / / / 37.5 INDX / / / / / / / / 46 INDX / / / / / / / / 37 ELA RTT ELA BS ELA INDX CM2 ELA WG4/8 ACCESSORIES ORDER SEPARATELY Remote transmitter Banding strap Ceiling-mount kit for INDX654/1236/1254 Wireguard 7-1/4 (18.4) 16 (40.6) 11-1/2 (29.2) 3/8 (1.0) 8-3/8 (21.3) 1 (2.5) 2-1/4 (5.5) 1/4 (0.6) 2-1/4 (5.7) 2-3/4 (7.0) 3/4 (1.9) 8 (20.3) 1 INDX12100 available with either the PREM or ULT package only. 2 All models provided with two lamp heads. 3 Must order a remote transmitter (ELA RTT). One per job required. 4 Only available on INDX618, INDX1236 or INDX UL Listed for -40 to 55 C (-40 to 131 F). 6 Add 0.3 amps, 31 watts for models with ULT option. For additional lamp heads, remote fixtures, options and accessories, see pages For application guidelines and fixture performance data, see pages 477 and

20 EMERGENCY LIGHTING UNITS ELT Titan Industrial Steel Provides a minimum of 90 minutes of illumination for the rated wattage upon loss of AC power. Designed for general/light industrial environments requiring a steel housing. Glass sealed-beam style lamps in polycarbonate lamp housings (metal housings standard on Chicago units). Housing is die-formed steel, finished with corrosion-resistant instrument tan enamel. Maintenance-free batteries. Lead-calcium standard; nickel-cadmium optional. Titan Series units will power a variety of remote devices up to rated wattage of unit. Chicago compliant: ELT24C and ELT36C meet city of Chicago requirements. New York City compliant: ELT618NY, ELT627NY and ELT1250NY meet New York City requirements. NY products feature 20-gauge, white steel housings and two (ELT618NY) or three (ELT627NY and ELT1250NY) PAR36 style thermoplastic lamp heads. Dual voltage input capability (120/277V). UL Listed. Meets UL924. Specialty ORDERING INFORMATION For shortest lead times, configure products using bolded options. Example: ELT24 Series Housing 2 Number of lamps 2 Lamp type Options ELT16 16W/6V Chicago compliant NYC compliant (blank) Instrument (blank) Two heads PAR36 sealed-beam N W/12V N Nickel-cadmium ELT24 24W/6V ELT24C 24W/6V 1 ELT618NY 18W/6V 1 tan R0 Less lamp 6V 3 incandescent battery 2 ELT36 36W/6V ELT36C 36W/6V 1 ELT627NY 27W/6V 1 W White heads (blank) 8W/6V H W/12V halogen H 8W halogen lamps 6 ELT50 50W/12V ELT1250NY 50W/12V 1 MT Metal lamp incandescent H W/12V halogen 5 AM Ammeter 7,8 heads ELT W/12V N W/6V H W/12V halogen 5 VM Voltmeter 7,8 incandescent ELT W/12V LD Load disconnect H W/6V halogen switch ELT W/12V 12V 4 TD Integral time delay 8,9 (blank) 12W/12V incandescent ELECTRICAL APPLICATION DATA TYPE AC INPUT OUTPUT OUTPUT WATTS VOLTS AMPS WATTS VOLTS 1-1/2 HRS 2 HRS 3 HRS 4 HRS ELT ELT ELT ELT ELT24C ELT24C ELT ELT ELT36C ELT36C ELT ELT ELT ELT ELT ELT ELT ELT ELT618NY ELT618NY ELT627NY ELT627NY ELT1250NY ELT1250NY ACCESSORIES ORDER SEPARATELY ELA WG2 Small wireguard (16-50W) ELA WG 4/8 Large wireguard (50-275W) ELA MSTS Mounting shelf (50-275W) 10 ELA MST Mounting shelf (16-50W) 10 Weight: Weight: 11-1/2 (29.2) 14 (35.6) 3-5/8 (9.2) 7-7/8 (20.0) ELT 16/24/24C: 12.5 lbs (5.7 kg) ELT 36/36C/50: 17 lbs (7.7 kg) 18 (45.7) 18 (45.7) 12 (30.5) 9 (22.9) ELT 125: 43.5 lbs (19.7 kg) ELT 180: 58.5 lbs (26.5 kg) ELT 275: 61.5 lbs (27.9 kg) 1 No options available. 2 Only available on ELT16, ELT24 and ELT50. 3 Only available on ELT16, ELT24 and ELT36. 4 Only available on ELT125, ELT180 and ELT Must be ordered with the MT option. 6 H option is a 6W lamp on the ELT24. 7 AM and VM must be ordered together. 8 ELT50 unit uses ELT125 housing when ordered with VM, AM or TD options. 9 Only available on ELT50, ELT125, ELT180 and ELT Standard color instrument tan

21 Provides a minimum of 90 minutes of illumination for the rated wattage upon loss of AC power. Designed for Class I, Division 2 environments. Impact-resistant, fiberglassreinforced polyester housing. Gray with stainless steel hardware. View-through window allows easy monitoring of AC indicator and optional voltmeter and ammeter. Housing suitable for use in NEMA 4, 4X, 12 and 13 areas; Class I, Division 2, Groups A, B, C and D, Zone 2, Groups IIA, IIB + H2 and IIC and Class II, Division 2, Groups F and G. Lamp heads are Class I, Div. 2 rated polycarbonate sealedbeam PAR36 tungsten or halogen lamps. 8W tungsten lamps for 6V units and 12W tungsten lamps for 12V units are standard. Optional shatter-resistant shield is designed for use in food-service areas. UL Listed. Meets UL924. Specialty Z - CLASS I, DIV. 2 Hazardous Location EMERGENCY LIGHTING UNITS ORDERING INFORMATION Lead times will vary depending on options selected. Consult with your sales representative. Example: Z650 N2506 SD Series Voltage 5 Number of lamps Lamp type Options 6V lead-calcium Z625 25W 1 Z650 50W 1 Z W 2,3 Z W 3 6V nickel-cadmium Z625N 25W 1,4 Z650N 50W 1,4 12V lead-calcium Z W 1 Z W 1,2 Z W 3 12V nickel-cadmium Z1225N 25W 1,4 Z1250N 50W 1,4 Z1275N 75W 1,4 Z12100N 100W 1,4 Z12125N 125W 1,4 (blank) 120/277V (blank) Two R1 One R0 None PAR36 sealed-beam, 6V (blank) 8W/6V incandescent N W/6V incandescent N W/6V incandescent N W/6V incandescent H0806 8W/6V halogen H W/6V halogen PAR36 sealed-beam, 12V (blank) 12W/12V incandescent N W/12V incandescent N W/12V incandescent N W/12V incandescent H0812 8W/12V halogen H W/12V halogen SD Self diagnostics 3 SDA Self diagnostics with alarm 3 AM Ammeter TD Time delay w/ SD or SDA TD1 Time delay 120 VAC w/o SD TD2 Time delay 277 VAC w/o SD SRS Shatter-resistant lamp head shield ELECTRICAL INPUT POWER REQUIRMENTS 120 VAC.58 amps max.65w max 277 VAC.27 amps max.68w max OPERATION DC VOLTAGE UNIT STANDARD WATTS TO 87.5% OF RATED VOLTAGE LAMP HEAD 1-1/2 HRS 2 HRS 4 HRS 8 HRS 6 Z625 N Z650 N Z6100 N Z6125 N Z625N N Z650N N Z1225 N Z1250 N Z12120 N Z1225N N Z1250N N Z1275N N Z12100N N Z12125N N SHIPPING WEIGHT Z lbs (8 kg) Z lbs (8 kg) Z lbs (12 kg) Z lbs (13 kg) Z625N 16 lbs (7 kg) Z650N 18 lbs (8 kg) Z lbs (13 kg) Z lbs (13 kg) Z lbs (10 kg) Z1225N 18 lbs (8 kg) Z1250N 18 lbs (8 kg) Z1275N 20 lbs (9 kg) Z12100N 29 lbs (13 kg) Z12125N 29 lbs (13 kg) 13-1/4 (33.7) 15-1/4 (38.7) 12-3/8 (31.4) 10 (25.4) 25W-75W Units 6-1/2 (16.5) 14-3/8 (36.5) 12 (30.5) 100W-125W Units 7 (17.8) 16 (40.6) 18 (45.7) 1 In addition to UL 924, units are listed to 844, 1203 and Includes temperature compensated charger. 3 Self diagnostics not available on Z6100, Z6125 and Z Nickel-cadmium units are the only units listed for Class II, Div. 2, Groups F and G applications. 5 Special voltages available; consult factory. 6 Option configurations may impact UL listing. Consult factory for specifics. For matching remote lamp head or other remote fixture options, see page

22 EMERGENCY LIGHTING UNITS LZ/LHZ - CLASS I, DIV. 2 Hazardous Location LZ LHZ Combo and EL N exit provide 90 minutes of operation for the rated wattage upon loss of AC power. Both are designed for Class I, Division 2 and Class II, Division 2 environments. Impact-resistant, fiberglass reinforced polyester housing. Gray with stainless steel hardware and clear polycarbonate cover. Includes one-piece formed gasket and corrosion-resistant hardware. Standard internal or external mounting feet for installation flexibility. Housing suitable for NEMA 4, 4X, 12 and 13 areas; Class I, Division 2, Groups A, B, C and D, Zone 2, Groups IIA, IIB + H2 and IIC. Lamp heads are Class I, Div. 2 rated polycarbonate sealedbeam PAR36 tungsten or halogen lamps. 6W halogen lamps standard. Dual-voltage input capability (120/277V). Specialty Optional shatter-resistant shield is designed for use in food-service areas. Non-diffuse LEDs provide maximum face illumination. LED life up to 25 years based on continuous operation. UL Listed. Meets UL924. ORDERING INFORMATION Lead times will vary depending on options selected. Consult with your sales representative. Example: LZ S 1 R 120/277 EL N SD Series LZ LED hazardous exit LHZ 6V, 6W lead-calcium battery 1 LHZ612 6V, 12W lead-calcium battery LHZ624 6V, 24W lead-calcium battery LHZ660 6V, 60W lead-calcium battery Face type Housing Number of faces S Stencil (blank) Gray 1 Single R Red G Green LED color Voltage Lamp heads 2 Lamp type 2 Operation Options 3 (blank) 2 heads R1 1 head R0 No heads PAR36 sealed beam (blank) 6W/6V halogen N0806 8W/6V incand. N W/6V incand. N W/6V incand. N W/6V incand. H0806 8W/6V halogen H W/6V halogen 120/277 Dualvoltage (blank) Nonemergency EL N Nickelcadmium battery SD Self diagnostics SDA Self diagnostics with alarm TD Time delay w/ SD or SDA TD1 Time delay 120 VAC w/o SD or SDA TD2 Time delay 277 VAC w/o SD or SDA SRS Shatter-resistant lamp head shield Lead times will vary depending on options selected. Consult with your sales representative. ELA ZCD - CLASS II, DIV. 1 Hazardous Location 13-1/2 (34.3) 11-1/2 (29.2) 6-5/8 (16.8) ELA ZCD model suitable for use in Class II and III, Divison 1 environments. Corrosion-resistant, cast aluminum alloy with epoxy polyester finish. Electrical (EXIT): input power requirements at 120V AC (red and green): AC only = 9.5W; emergency operation = 11W,.90 power factor Electrical (Combo): input power requirements at 120V AC: Red or green = 25.2W max. 1 LHZ has 6W total capacity. Will be shipped with one 6W lamp head unless RO option is selected. 2 Not available with LZ. 3 Some option configurations may impact UL listing; consult factory for details. Top-mount fixture with single wall remote has universal junction box with four tapped holes for 3/4" rigid conduit (three close-up plugs provided). Twin wall remote has junction box with two tapped holes for 3/4" rigid conduit (one close-up plug provided). UL Listed (standard). Meets UL 844 and 1203 illumination standards. UL Listed for use in Class II, Division 1, Groups E, F, G and Class III areas. Specialty ORDERING INFORMATION Lead times will vary depending on options selected. Consult with your sales representative. Example: ELA ZCD H1212 WM H W/6V halogen Series Number of lamps Lamp type Mounting Options ELA ZCD Hazardous combustible dust (blank) Single WM Wall mount WGZCD Wireguard 2 T Twin 1 H W/12V halogen TM Top mount SM Side mount to ZX1250N unit Shipping weight: 18 lbs (8 kg) 4-1/4 (10.8) 9-3/4 (24.8) 16-3/8 (41.6) 8-3/8 16-1/8 (21.3) (41.0) 8 (20.3) 16-3/8 (41.6) 16-3/8 (41.6) 6 (15.2) 15 (38.1) 5-3/8 5-3/8 (13.7) (13.7) 5-3/8 (13.7) 5-3/8 ELA ZCD H1206 TM ELA ZCD H1206 WM ELA ZCD T H1206 WM (13.7) ELA ZCD H1212 SM 12 (30.5) 1 Only available with wall mount. 1 Order separately ELA WG2CD

23 Suitable for use in Class I, Div. I, Groups C and D, Zones 0, 1 and 2, Groups IIA, IIB + H2 and IIC; Class I, Div. 2, Groups Series C and D, Zone 2, Groups IIA, IIB + H2 and IIC; Class II, Div.1, Groups E, F and G; Class I, Div. 2, Groups F and G, and Class III hazardous location areas. 6V lead-calcium 6V nickel-cadmium ZX685 85W 1 ZX614N 14W 2 ZX628N 28W Copper-free cast-aluminum enclosure withstands explosions generated by internal arc without propagating them into hazardous atmosphere. Dual-voltage input capability (120/277V). UL Listed (standard). Options KLD Key lock two-way, battery disconnect for servicing 12V nickel-cadmium ZX1250N 50W 1 TD1 Time delay 120 VAC TD2 Time delay 277 VAC Specialty ZX - CLASS I, DIV. 1 Hazardous Location ORDERING INFORMATION Lead times will vary depending on options selected. Consult with your sales representative. Example: ZX614N TD1 EMERGENCY LIGHTING UNITS THE SAMPLE APPLICATION CONSISTS OF: (1) ZX614N - 14W power pack for exclusive use with compact fluorescent fixtures (2) ELA SEA - Elbow arms (2) ELA ZX CF0706 PM - 7W compact fluorescent lamp fixture (1) ELA EAK - Exit accessory kit ACCESSORIES ORDER SEPARATELY ELA ZX DRH 12W/12V directional head 3 Suitable for use in Class I, Div. 1, Groups C and D, Zones 0, 1 and 2, Groups IIA, IIB + H2 and IIC; Class I, Div. 2, Groups C and D, Zone 2, Groups IIA, IIB + H2 and IIC; Class II, Div. 1, Groups E, F and G; Class I, Div. 2, Groups F and G and Class III hazardous location areas. Copper-free, cast-aluminum enclosure withstands pressure of explosions generated by internal arc without propagating SHIPPING WEIGHT ZX614N 63 lbs (28 kg) ZX628N 65 lbs (29 kg) ZX1250N 67 lbs (30 kg) ZX lbs (31 kg) them into hazardous atmosphere. Enclosure has corrosion-resistant, epoxy powder coat finish. 4 (10.2) Top- and wall-mount fixtures have a universal junction box with four tapped holes for 10 (25.4) 7 (17.8) ELA ZX DRH Accessory 3/4" rigid conduit (three hole plugs provided). UL Listed (standard). Meets UL 844 illumination standards. 12 (30.5) 10 (25.4) 13 (33.0) 15 (38.1) 8-7/8 (22.5) 3-1/2 (8.9) 6 ( Incandescent emergency lamp operation only. 2 Compatible only with ELA ZX remotes using 7W compact fluorescent lamps. Will not operate incandescent lamps. Maximum remote mounting distance is 8'. 3 Must be used with ZX1250N unit. Specialty ELA ZX - CLASS I, DIV. 1 Hazardous Location ORDERING INFORMATION Lead times will vary depending on options selected. Consult with your sales representative. Series Head style Lamp type Mounting ELA ZX Explosion-proof Emergency only, halogen H W/6V halogen WM Wall mount H0706 7W/6V halogen H W/12V halogen PM Pendant mount H W/6V halogen AC / emergency operation TM Top mount CF0706 7W compact fluorescent 1 ELA 3CH ELA SEA ELA EAK ELA SDR ACCESSORIES ORDER SEPARATELY 3-way explosion-proof 3/4" conduit hub. Swivel elbow arm for use with pendant-mount fixture to connect to ELA 3CH or ELA ZX unit. Exit accessory kit (red silk-screened letters on white background). Straight dome reflector. mechanical configuration. Dimensions are shown in inches (centimeters) Shipping weight: 15 lbs (7 kg) 12 (30.5) Accessory 17-7/8 (45.4) 7/8 (2.2) 10-1/2 (26.7) 7-3/8 (18.7) Wall Mount 14-3/8 (36.5) 7-1/4 (18.4) Ceiling Mount 14-3/8 (36.5) Example: ELA ZX H0706 WM 7-1/4 (18.4) 14-7/8 (37.8) Pendant Mount 1 Operates only with ZX614N power pack in AC and emergency modes. Maximum mounting distance from ZX 614N is 8'. See specification sheet UE-296 for details

24 EMERGENCY LIGHTING UNITS ELA Remote Lamp Heads To be powered by 6, 12 or 24V battery equipment as part of an emergency lighting system providing light for the path of egress. Order separately. Remote Fixtures & Accessories Standard PAR36 Multi-Faceted Reflector Indura Remote Sealed and Gasketed PAR36 Metal PAR36 Hazardous PAR36 ORDERING INFORMATION Lead times will vary depending on options selected. Consult with your sales representative. Example: ELA IND H2012 Series Finish Number of lamps Lamp head style Lamp type 1 ELA (blank) Standard color B Black W White ITN Instrument tan (Titan Series match) TN Desert tan Specify color, see availability table below (blank) Single T Twin (blank) Standard PAR36 MR24 Multi-faceted reflector IND Indura 2 NX MT Z Sealed and gasketed PAR36 Metal PAR36 Hazardous PAR36 (Class I, Division II) Specify lamp type, see configuration tables below. COMPOSITE LAMPS 6V HALOGEN 6V KRYPTON 12V HALOGEN 12V KRYPTON 24V INCANDESCENT 24V HALOGEN Wattage 12W 20W 6W 9W 12W 20W 9W 18W 20W Lamp type H1206 H2006 K0606 K0906 H1212 H2012 K0912 N1824 H2024 MR24 IND SEALED-BEAM LAMPS 6V INCANDESCENT 6V HALOGEN 12V INCANDESCENT 12V HALOGEN 24V INCANDESCENT 120V PAR36 Wattage 8W 12W 18W 6W 8W 12W 12W 18W 25W 35W 8W 12W 35W 50W 50W 15W 30W 50W Lamp type N0806 N1206 N1806 H0606 H0806 H1206 N1212 N1812 N2512 N3512 H0812 H1212 H3512 H5012 N5024 N15120 N30120 N50120 IND 2 NX Standard PAR36 MT Z REMOTE HEAD AND DIMENSIONS 3 WIDTH WIDTH (SINGLE HEAD) (TWIN HEADS) HEIGHT (SINGLE HEAD) HEIGHT (TWIN HEADS) SERIES STANDARD COLOR OTHER COLOR DEPTH Standard PAR36 Desert tan White, black, instrument tan 4-3/4 (12.1) 13 (33) 7-3/4 (19.7) 7-3/4 (19.7) 5-1/16 (12.9) MR24 White Black 4-5/8 (11.7) 6-5/8 (16.8) 6-5/8 (16.8) 4-1/2 (11.4) 2-1/2 (6.3) IND Gray/blue White 5-7/8 (14.9) 7-1/8 (18.1) 5-1/8 (13) 5-1/8 (13) 5-3/8 (13.7) NX Gray White, black 4-3/4 (12.1) 13 (33) 7-3/4 (19.7) 7-3/4 (19.7) 5-1/16 (12.9) MT Brushed aluminum N/A 4-5/8 (11.7) 10-1/2 (26.7) 5-1/8 (13) 5-1/8 (13) 6-1/2 (16.5) Z Gray N/A 4-3/4 (12.1) 1" (33) 7-3/4 (19.7) 7-3/4 (19.7) 5-1/16 (12.9) = Available MOUNTING PLATE DIMENSIONS 3 SERIES WIDTH HEIGHT MT (single head) 2-3/4 (7.0) 4-1/2 (11.5) MT ( twin heads) 4-9/16 (11.6) 4-1/2 (11.5) IND 5-1/8 (13) 4-11/16 (11.9) MR24 6-7/8 (17.5) 4-5/8 (11.7) All others 3-1/8 (7.9) 5 (12.7) 1 Consult factory for addtional lamp availability. 2 For Indura sealed beam lamps, addd suffix S to lamp nomenclature. Example: H3512S. For photometric information, visit 3 Dimensions are shown in inches (centimeters)

25 Remote Fixtures Open Cone 1 6" PAR36 2 ELA OC NO806 (6V/8W) ELA OC HO806 (6V/8W) ELA OC N1212 (12V/12W) 3" MR16 LV3 Series ELA LV3 OC H1006 ELA LV3 OC H1012 L = 11-3/8 (28.9), W = 8-3/8 (21.3), H = 8-1/2 (21.6) Square Series ELA SQR6V (6V/10W) ELA SQR12V (12V/12W) Note: Order ELA FRK for fully recessed mounting or ELA SRK for semi-recessed mounting. Stepped Baffle 6" PAR36 2 ELA SB NO806 (6V/8W) ELA SB HO806 (6V/8W) 2 ELA OC N1212 (12V/12W) 3" MR16 LV3 Series ELA LV3 SB H1006 ELA LV3 SB H1012 L = 11-3/8 (28.9), W = 8-3/8 (21.3), H = 8-1/2 (21.6) Surface Gimbal ELA SG N1212 (12V/12W) ELA SG N1812 (12V/18W) ELA SG N2512 (12V/25W) ELA SG HO812 (12V/8W) ELA SG H1212 (12V/12W) Eyeball 1 6" PAR36 2 ELA EB NO806 (6V/8W) ELA EB N1212 (12V/12W) ELA EB H1212 (12V/12W) 3" MR16 LV3 Series ELA LV3 EB H ELA LV3 EB H L = 11-3/8 (28.9), W = 8-3/8 (21.3), H = 5-1/2 (14.0) Recessed Gimbal ELA RG N1212 (12V/12W) ELA RG N1812 (12V/18W) ELA RG N2512 (12V/25W) ELA RG HO812 (12V/8W) ELA RG H1212 (12V/12W) Remote Fixtures & Accessories Recessed Rectangle ELA RR S8 or S11 DC bayonet base lamp up to 25W (not included) L = 8-1/4 (21.0), W = 4-1/2 (11.4), D = 3-3/8 (8.6) Weatherproof ELA AFNR Two 6W, 6V, Xenon lamps EMERGENCY LIGHTING UNITS L = 10-5/8 (27.0), W = 10-5/8 (27.0), H = 3-1/2 (8.9) Diameter = 7-7/8 (20.0), depth = 5 (12.7) Diameter = 8-1/4 (21.0), Depth = 5-1/4 (13.3) L = 9-1/2 (24.1), W = 6-1/2 (16.5), D = 2-3/4 (6.9) Outdoor Step Light Outdoor Mini Cylinder 3 MR11 Round Outdoor Step Light ELA OSL ELA OMC DDB MR16 12W halogen bi-pin lamp ELA OMC DNA ELA CL (not included) ELA OMC H1006 (6V/10W) H1006 (6V/10) H2006 (6V/20W) H2006 (6V/20W) H1012 (12V/10W) H1012 (12V/10W) H2012 (12V/10W) H2012 (12V/20W) 1 Rough-in section same as Lithonia Lighting downlighting LV Series, less transformer. 2 Other lamps available. 3 Twin version available. Dimensions are shown in inches (centimeters) unless otherwise noted. WIREGUARD COMPATIBILITY / UL LISTED PRODUTS ELT 50 1 (W/ OPTIONS), 125 1, 180 1, 250 1, 275 1, INDX ELT 50 (W/ OPTION), 125, 180, 250, 275 IND ( W) ELM618, ELM627, ELM654, ELM1254, ELM1272 ELM; ELM2; ELT 16, 24, 36, 50; ELSQ IND (100W w/ PREM or ULT; W) DIMENSIONS SINGLE REMOTE TWIN REMOTE CATALOG NUMBER HEADS HEADS ELA WGLG 21W x 20H x 18D ELA WGLT 22-15/16W x 24-3/8H x 12-3/8D ELA WGRH 11-15/16W x 12-3/8H x 9-3/8D ELA WGST 15W x 15H x 6D ELA WG2 15-1/8W x 14-3/8H x 8-5/8D ELA WG2M 20-1/4W x 15H x 12D ELA WG4/8 22-1/8W x 22-15/16H x 10D = Available Unit Accessories Vandal Shield ELA VS2 ELA VS Remote Test Switch Less Pilot Light ELA RTLP 1/8," thick, (ELAVS2) high-impact or 3/16" thick (ELAVS) transparent polycarbonate shield. Fits all Lithonia Lighting Quantum ELM and ELM2 (ELA VS), ELM618, ELM627, ELM654, ELM1254 and ELM1272 (ELA VS2) units. 10" H x 22" W x 9-3/4" D (ELA VS2); 8-1/2" H x 15" W x 4-3/4" D (ELA VS). Provides remote testing capability to all Lithonia Lighting unit equipment, exit signs, fluorescent battery packs and emergency downlights. Mounts on standard J-box, ceiling or wall. Low-Voltage Relay ELA LVR Mounting Shelves ELA MST 2 ELT125, ELT180, ELT275 ELA MSTS 2 ELT16, ELT24, ELT24C, ELT36, ELT36C, ELT50 Converts any incandescent lowvoltage (12V) downlight (75W maximum) to an emergency downlight when remoted from a 12V Lithonia Lighting emergency lighting unit (ELT125, etc.). 1 Without heads. 2 Standard instrument tan

26 EXIT SIGNS EXIT SIGNS Ideal for applications requiring general-purpose emergency lighting. Thermoplastic housing. Dual voltage 120/277VAC. LED illuminated exit features low energy consumption. Fully assembled single-face exit with extra faceplate. Universal (top, end or back) mounting with canopy included. Battery back-up models provided with test switch and status indicator for visual and manual means of monitoring system operation. One-year warranty. UL Listed. Contractor Select Stock ORDERING INFORMATION CATALOG NUMBER DESCRIPTION VOLTS AMPS WATTS STANDARD CARTON QTY. EXR M6 Red EXR M6 Red EXG M6 Green EXG M6 Green EXR EL M6 Red with backup battery EXR EL M6 Red with backup battery EXG EL M6 Green with backup battery EXG EL M6 Green with backup battery /2 (19.1) 12-1/4 (31.1) 1-7/8 (4.8) EXIT-UNIT COMBOS Ideal for applications requiring general-purpose emergency lighting. Thermoplastic housing. Dual voltage 120/277VAC. LED illuminated combo sign features low energy consumption. Fully assembled single-face combo comes with optional extra faceplate. Top or back mounting capabilities. Canopy provided. Two 5.4W lamps to provide emergency lighting for 90 minutes, included. Highoutput option yields 12W extra capacity. Provided with test switch and status indicator for visual and manual means of monitoring system operation. Contractor Select Stock One-year warranty. UL Listed. ORDERING INFORMATION CATALOG NUMBER DESCRIPTION VOLTS AMPS WATTS 1 STANDARD CARTON QTY. ECR M6 Red ECR M6 Red ECG M6 Green ECG M6 Green ECR HO M6 Red, high output ECR HO M6 Red, high output ACCESSORIES ORDER SEPARATELY CATALOG NUMBER DESCRIPTION VOLTS WATTS 1 STANDARD CARTON QTY. ELA 6CS M12 Single remote head ELA T 6CS M12 Double remote head ELA T 6CS WP M12 Double remote head, weather proof (55.9) 11 (27.9) ECR/ECG ECR HO Weight: 8.0 lbs (3.6 kg) 10.3 lbs (4.7kg) 5 (12.7) 6-1/2 (16.5) ELA 6CS 11 (27.9) ELA T 6CS 5 (12.7) 11 (27.9) ELA T 6CS WP 1 Per lamp head. 5 (12.7) 5 (12.7)

27 Ideal for applications requiring general-purpose emergency lighting. Injection-molded, V-O flameretardant, high-impact thermoplastic housing. Dual voltage 120/277VAC. Two 5.4W lamps provide emergency lighting for 90 minutes. Test switch and status indicator provided for visual and manual means of monitoring system operation. One-year warranty. UL Listed. Meets UL924. Indoor damp location listed standard. Contractor Select Stock EMERGENCY UNITS EMERGENCY LIGHTING UNITS ORDERING INFORMATION CATALOG NUMBER EU2 M6 EU2 M6 DESCRIPTION VOLTS AMPS WATTS 1 STANDARD CARTON QTY. White thermoplastic 6-volt self-contained emergency lighting unit White thermoplastic 6-volt self-contained emergency lighting unit /8 (13.0) 16-1/2 (41.9) Max. weight: 4 lbs (1.8 kg) 2-3/8 (6.0) 1 Per lamp head. Operates most 2' or 4' linear or U-shaped single T8 or T12 fluorescent lamp for 90 minutes. Compatible with most electronic T8 and magnetic T12, instant-start, rapid-start and slimline ballasts. Field installable only. Low-profile black, 20-gauge steel, permanently sealed housing. Rated 500 lumens with one F32T8 linear 4' lamp. Other lamp lumen ratings will vary. Patent integrated test switch pilot light. US PATENT No. 6, 522, 147. Sealed, maintenance-free, high-temperature nickelcadmium battery. Dual-voltage input capability (120/277V). UL Listed. Contractor Select Stock FLUORESCENT BATTERY PACKS ORDERING INFORMATION CATALOG NUMBER DESCRIPTION VOLTS AMPS WATTS STANDARD CARTON QTY. EI500 M lumen fluorescent battery pack EI500 M lumen fluorescent battery pack /4 (5.7) 1 (2.5) 9-3/8 (23.8)

28 FLUORESCENT BATTERY PACKS PS Power Sentry Factory- or field-installed inside or outside (field only) a fluorescent fixture to operate lamp(s) at an initial output of 10% to 95% of rated lamp lumens, providing optimum glare-free illumination for a minimum of 90 minutes upon interruption of normal power. Mounts concealed within fixture wireway for clean appearance and protection against vandalism. Reduced-profile footprint fits in the tightest application. Durable thermoplastic/ metal housing resists impact, scratches and corrosion. Sealed, maintenance-free, high-temperature nickelcadmium batteries. Quick-disconnect connector system allows for quick and easy replacements at end of life without re-wiring. Patents pending. U.S. patent No. 5, 814, 971. UL Listed. Damp location listing available. Power Sentry Linear Fluorescent ORDERING INFORMATION For shortest lead times, configure products using bolded options. Example: PS1400QD SD Series 1 Options Factory installation 4,5 PS300QD Reduced profile, quick disconnect, 300-lumen output PSQ500QD Reduced profile, quick disconnect, 15-minute installation, 500-lumen output PS600QD Reduced profile, quick disconnect, 600-lumen output PS1400QD Reduced profile, quick disconnect, 1400-lumen output SD Self diagnostics 2 DW UL Listed for use inside damp or wet location listed fixtures 32 to 122 F (0 to 50 C) 3 EL PS300QD installed EL5 PSQ500QD installed 6 EL6 PS600QD installed 6 EL61LP PS600QD one-lamp operation installed 6 EL14 PS1400QD installed 6 EL141LP PS1400QD one-lamp operation installed 6 ELECTRICAL APPLICATION DATA TYPE AC INPUT VOLTS AMPS WATTS PS300QD 120/ PSQ500QD 120/ PS600QD 120/ PS1400QD 120/ /4 (3.2) 1-5/8 (4.1) ACCESSORIES ORDER SEPARATELY Field installable self-diagnostic modules for PSSD PSQ500 DW, PSQ500QD, PS600 DW, PS600QD, PS1400 DW or PS1400QD Remote or replacement test switch/pilot light ELA TSPLP and mounting plate for PS300, PS300QD, PSQ500, PSQ500QD, PS600, PS600QD, PS1400 and PS1400QD. Remote or replacement test switch/pilot light and ELA TSPLP SD mounting plate for self-diagnostics PSQ500SD, PSQ500QDSD, PS600SD, PS600QDSD, PS1400SD and PS1400QDSD ELA PSTS Double-pole, single-throw test switch (no pilot light) ELA PSMK External mounting kit 7 ELA PSMKSD External mounting kit for self-diagnostics module ELA PSDMT External mounting tray ELA PSRME External mounting box for PS300QD, PSQ500QD, PS600QD and PS1400QD 2-1/4 (5.7) PS300QD/ PS500QD PS600QD PS1400QD Length : 9-1/2 (24.1) 9-1/2 (24.1) 13-7/8 (35.2) Shipping weight: 1 lb (0.5 kg) 1.5 lbs (0.7 kg) 2 lbs (0.9 kg) 2-1/2 (6.4) PS300DW PS500DW Length : 9-1/2 (24.1) 9-1/2 (24.1) Shipping weight: 1.4 lbs (0.6 kg) 1.0 lbs (0.5 kg) PS600DW PS1400DW Length : 9-1/2 (24.1) 13-7/8 (35.2) Shipping weight: 1.8 lbs (0.8 kg) 4.0 lbs (1.8 kg) 1 Lumen rating based on initial output of one 32W T8 lamp. 2 Self-diagnostics (PSSD) module ships separately. See PSSD spec sheet for details. Not available on PS300QD. 3 Not available with quick-disconnect wire harness. See housing dimensions. 4 To order a factory-installed battery pack, add suffix to fluorescent fixture catalog number. 5 Add DW to factory-installed suffix to receive as wet or damp location listed, depending on the fixture. Applies to EL, EL5, EL6, EL14. Example: EL14 DW. 6 Add SD to suffix to receive self-diagnostics version. Example: EL5SD. Applies to EL5, EL6 and EL14. 7 For DW option only. For lamp/ballast compatibility, see page 474. For application guidelines and fixture performance data, see page

29 Factory- or field-installed inside or outside (field only) a fluorescent fixture to operate lamp(s) at an initial output of 10% to 95% of rated lamp lumens, providing optimum glare-free illumination for a miniumum of 90 minutes upon interruption of normal power. Dual-voltage input capability (120/277V). Sealed, maintenance-free, high-temperature nickelcadmium batteries. Housing is 20-gauge steel or permanently sealed steel. Power Sentry Linear Fluorescent PS48 PS600C PS3000 Power Sentry FLUORESCENT BATTERY PACKS ORDERING INFORMATION Lead times will vary depending on options selected. Consult with your sales representative. Example: PS3000 Series Factory installation 2 PS600C Two-hour emergency operation PS3000 Full light output 1 PS48 Central 48VDC interface EL6C EL48 PS600C installed PS48 installed ELECTRICAL APPLICATION DATA TYPE AC INPUT VOLTS AMPS WATTS PS600C PS600C PS PS PS PS ELA RTS2 ELA RTS3 ELA PSTS ELA PSDMT ACCESSORIES ORDER SEPARATELY Remote test switch and pilot light (PS3000) Remote test switch and pilot light (PS600C) Double-pole, single-throw test switch (no pilot light) External mounting tray (PS3000) 2-3/8 (6.0) 1-1/2 (3.8) Length: 9-3/8 (23.8) Weight: 2.5 lbs (1.1 kg) PS48/PS600C 5-5/8 (14.3) Length: 15-3/8 (39.1) Weight: 10.3 lbs (4.7 kg) PS (5.1) 1 Light output based on one 32W T8 lamp. 2 To order a factory-installed battery pack, add suffix to fluorescent fixture catalog number. Series PSSD Designed to perform self-diagnostic testing for five minutes every month and 30 minutes every six months. May be factory- or field-installed as part of the test switch/pilot light assembly with the PSQ500 Self-diagnostic module for PSQ500 QD or DW, PS600 QD or DW, PS1400 QD or DW, and PSDL3 QD or DW. UL approved for use in wet and damp location listed fixtures 0-50 C. DW, PSQ500QD, PS600 DW, PS600QD, PS1400 DW, PS1400QD and PSDL3. Single multi-chromatic status indicator and audible beep to display three-state charging, test activation and four-state diagnostic status. Audible beep can be permanently deactivated in the field. Quickconnect terminal allows for fast and easy installation. UL Listed for use inside damp or wet location listed fixtures 32 to 122 F (0 to 50 C). Power Sentry Linear Fluorescent ORDERING INFORMATION For shortest lead times, configure products using bolded options. Example: PSSD ACCESSORIES ORDER SEPARATELY ELA TSPLP SD Remote or replacement test switch/pilot light (with plenum-rated cable) for self-diagnostics ELA PSMKSD External mounting kit for self-diagnostics module PSSD Power Sentry

30 FLUORESCENT BATTERY PACKS PSL Power Sentry Low-Profile Factory- or field-installed inside or outside (field only) a fluorescent fixture to operate lamp(s) at an initial output of 10% to 95% of rated lamp lumens, providing optimum glare-free illumination for a minimum of 90 minutes upon interruption of normal power. Low-profile footprint and T5 lamp compatibility make the PSL550 and PSL600 battery pack ideal for use in T5 direct/indirect fixtures. Dual-voltage input capability (120/277V). Sealed, maintenance-free, high-temperature nickelcadmium batteries. Housing is 20-gauge steel or permanently sealed steel. UL Listed. Power Sentry Linear Fluorescent ORDERING INFORMATION Lead times will vary depending on options selected. Consult with your sales representative. Example: PSL600 Series Factory installation 1 PSL400 Low-profile, lumen output - T8, T12 ELSC4 PSL400 installed PSL550 Low-profile, lumen output - T5, T8 EL55 PSL550 installed PSL600 Low-profile, lumen output - T5, T8 EL65 PSL600 installed ELECTRICAL APPLICATION DATA TYPE AC INPUT VOLTS AMPS WATTS PSL PSL PSL PSL PSL PSL ELA RTS3 ELA PSTS ACCESSORIES ORDER SEPARATELY Remote test switch and pilot light for the PSL400, PSL550, PSL600 and PS600C Double-pole, single-throw test switch (no pilot light) 1-1/2 (3.8) 1 (2.5) Length: 14-1/8 (35.9) Weight: 1.9 lbs (0.9 kg) PSL /8 (2.9) 1-1/8 (2.9) Length: 18.5 (47.0) Weight: 2.4 lbs (1.1 kg) PSL /8 (2.9) 1-1/8 (2.9) Length: 21.5 (54.6) Weight: 3.0 lbs (1.4 kg) PSL600 1 To order a factory-installed battery pack, add suffix to fluorescent fixture catalog number

31 Factory- or field-installed on fluorescent down lighting fixtures to operate lamps at an initial light output of 20% to 85% of full lumen rating, providing optimum glare-free illumination for a minimum of 90 minutes upon interruption of normal power. PSDL1 operates one two-pin 18W or 26W quad-tube compact fluorescent lamp. PSDL1 2LP operates two, two-pin (13-26W) quad-tube fluorescent lamps. PSDL2 operates one, two-pin 7W, 9W or 13W compact fluorescent lamp. PSDL3 operates one or two, four-pin twin-tube (9-13W), tripletube (18-42W*), quad-tube (13-26W) or 2D compact fluorescent lamp(s). *42W triple-tube is one-lamp only. Dual-voltage input capability (120/277V). Sealed, maintenance-free, high-temperature nickelcadmium batteries. Housing is permanently sealed steel enclosure. UL Listed. Power Sentry Compact Fluorescent PSDL Power Sentry FLUORESCENT BATTERY PACKS ORDERING INFORMATION For shortest lead times, configure products using bolded options. Example: PSDL3 SD Series Options Factory installation 3 PSDL1 Bi-pin (18-26W) quad-tube lamps PSDL2 Bi-pin (7-13W) twin-tube or quad-tube lamps PSDL3 Four-pin (9-42W) quad-tube or triple-tube lamps SD Self diagnostics 1 DL UL listed for damp location 0-50 C ( F) 1 2LP Operates two, two-pin quad-tube lamps (PSDL1) 2 EL PSDL1/PSDL2/PSDL3 installed, compact fluorescent ELR PSDL1/PSDL2/PSDL3 installed, compact fluorescent with remote pilot light/test switch ELECTRICAL APPLICATION DATA TYPE AC INPUT VOLTS AMPS WATTS PSDL PSDL PSDL PSDL PSDL PSDL PSSD ELA TSPLP ELA PSTS ELA PSDMT ELA RTS3 ACCESSORIES ORDER SEPARATELY Field-installable self-diagnostic module for PSDL3 Remote or replacement test switch/mounting plate for PSDL3 Double-pole, single-throw test switch (no pilot light) External mounting tray (PSDL1, PSDL2, PSDL3) Remote test switch and pilot light for PSDL1 2LP 2-3/8 (6.0) Length: 10-5/8 (27.0) Shipping weight: 2.1 lbs (1.0 kg) PSDL1 and PSDL2 1-1/2 (3.8) 3-1/4 (8.3) 1-3/4 (4.4) Length: 17-1/8 (43.5) Shipping weight: 5.0 lbs (2.3 kg) PSDL3 2-3/8 (6.0) Length: 12 (30.5) Shipping weight: 3.0 lbs (1.4 kg) PSDL1 2LP 1-1/2 (3.8) 1 Available on PSDL3. Self-diagnostics (PSSD) module ships separately. 2 Must specify PSDL1 2LP for two-lamp version. The PSDL3 product may be wired for a two-lamp operation as a standard feature; see wiring diagrams. 2LP option does not need to be specified for the PSDL3. 3 To order a factory-installed battery pack, add suffix to fluorescent downlighting fixture catalog number. PSDL1/PSDL2/PSDL3 will be determined automatically based on ballast and lamp type. Add 2LP (example: EL2LP) to suffix to specify two-lamp emergency operation for all four-pin or two-pin quad lamps. (Available for Gotham downlighting and Lithonia Lighting downlighting.)

32 CENTRAL INVERTER SYSTEMS EAC ISS Automatic standby AC power systems for incandescent and fluorescent emergency lighting loads that provide full light output for 90 minutes of operation. Features Microprocessor-controlled PWM inverter with IGBT technology allows for universal compatibility. Standard RS232 interface allows communication with system from remote computer. Low-voltage disconnect, short-circuit protection, current-limiting and brown-out protection. Stackable, modular cabinet design enabling versatile installation. Systems 4KVA and below are self-contained. Larger systems require external, stackable battery cabinets. Standard digital meter panel displays input/output voltage, battery voltage and output current. 24-hour battery recharge standard. 50-millisecond transfer time. UL 924 Listed for 90 minutes of emergency operation. ORDERING INFORMATION Lead times will vary depending on options selected. Consult with your sales representative. Example: EAC ISS /120 OB Series Battery System VA rating 1 Voltage 2 Options EAC Emergency AC power system (blank) Lead-calcium, 10-year life (blank) Battery LC20 Lead-calcium battery, 20-year life 12HR ISS Interruptible Input/output 120/ / / / / None 12-hour battery recharge Electronic TD Time delay (15 minutes) Input/output OB Output circuit breaker (specify quantity and amps) 3 OTA Output trip alarm Miscellaneous FSP Factory start-up program RMP Remote meter panel MBYP Maintenance bypass switch MODEM External modem RS232 DFC Form "C" contact 47 (119.4) 30 (76.2) EAC ISS 25 (63.5) 1 Systems 4800 (5KVA) or larger require external battery cabinets. 2 Consult factory for other voltages. 3 Standard 20-amp, normally on unless otherwise specified

33 An off-line AC power system for the emergency operation of HID, incandescent and fluorescent emergency lighting loads that provides full light output for 90 minutes of operation. Free-standing NEMA Type 1 cabinet. Microprocessor-controlled PWM inverter with IGBT technology allows for universal compatibility. FT and 3FT have a 65K amp inrush current rating. Sinusoidal output waveform has <3% THD. Off-line uninterruptable system has 2-millisecond transfer time. Standard circuit protection: low-voltage disconnect, short-circuit protection, current-limiting, fusedbattery protection, brownout protection, input circuit breaker. Standard RS232 diagnostic interface on FT and 3FT. UL Listed (standard) for 90 minutes of emergency operation. EAC FTT output ranges: 500 VA to 2000 VA. Single-phase system. Field upgradable (500 VA system). EAC FT output ratings: 1,500 VA to 16,700 VA. Singlephase system. EAC 3FT output ratings: 4,800 VA to 50,000 VA. Three-phase system. EAC FT E AC F T T EAC 3FT CENTRAL INVERTER SYSTEMS ORDERING INFORMATION Lead times will vary depending on options selected. Consult with your sales representative. Series Battery System VA rating Voltage 6 Options EAC Emergency (blank) Lead-calcium, FTT Compact Input/output (blank) None AC power 10-year life fast 1000 system LC20 Lead-calcium, transfer /120 3 Battery year life 1 FT Fast / HR 12-hour transfer /120 4 battery recharge 1 3FT 3-phase / Supervisory fast / transfer RMP Remote meter panel MBYP Maintenance bypass switch 7 XMBYP External maintenance bypass switch Input/output OB Output circuit breaker (specify quantity and amps) 8 OTA Output trip alarm Example: EAC 3FT DFC Miscellaneous FSP Factory start-up program DFC Form "C" contacts NOFF Normally OFF output circuit 9 MODEM External modem for RS (25.4) (119.4) 10 (25.4) 30 (76.2) 25 (63.5) 10 (25.4) 26 (66.0) EAC FT or EAC 3FT EAC FTT 1 Available on FT and 3FT only. 2 Available on FTT only. 3 Available on FTT and FT only. 4 Available on FT only. 5 Available on 3FT only. 6 Consult factory for other voltage requirements. Special voltages may affect the weight, size and number of cabinets. 7 Standard on 3FT. 8 Standard 20-amp normally on unless otherwise specified. 9 Normally off load cannot exceed 20% of total VA rating with any combination of HID loads

34 GENERAL INFORMATION POWER SENTRY BATTERY PACKS Lamp/Ballast Compatibility Spacing Guidelines Performance Data POWER SENTRY LAMP BALLAST COMPATIBILITY UL LISTED PRODUCTS LAMP TYPE WATTAGE PS300QD PSQ500QD PS600QD PS1400QD PSL400 PSL550 PSL600 PS600C PS3000 PS48 PSDL1 PSDL2 PSDL3 24" - 48" T " - 48" T5H U-lamp T , 2 1, 2 1 1,2 1,2 24" - 48" T , 2 1, ,2 1,2 48" - 60" T " - 96" T " T8HO Circline T ,2 1 U-lamp T , 2 1, 2 1 1,2 1,2 24" - 48" T , 2 1, ,2 1,2 60" - 96" T " - 48" T12H " - 96" T12HO " - 48" T12VHO " - 96" T12VHO PL Twin-Tube (2-Pin) PL Quad-Tube (2-Pin) , 4 PL Twin-Tube (4-Pin) ,2 1 PL Quad-Tube (4-Pin) , 2 1 1,2 1,2 Triple-Tube (4-Pin) , ,2 Triple-Tube (4-Pin) Long Compact (4-Pin) ,2 Long Compact (4-Pin) ,2 = Available 2GT8 2 U316 2SP8 2 U316 2X2 2AV 2 CF40 2PM3N 2 U316 POWER SENTRY SPACING GUIDELINES 5,6,7 2PMO 2 U31 2GT SP X4 2AV PM3N PMO TURRET INDUSTRIALS CATALOG 1FC 1FC 1FC 1FC 1FC 1FC 1FC 1FC 1FC 1FC 1FC NUMBER AVG. MIN. AVG. MIN. AVG. MIN. AVG. MIN. AVG. MIN. AVG. MIN. AVG. MIN. AVG. MIN. AVG. MIN. AVG. MIN. AVG. MIN. PS300QD CORRIDOR PSQ500QD PS600QD PS1400QD PS300QD OPEN OFFICE PS500QD PS600QD PS1400QD INDUSTRIAL PS1400QD One-lamp emergency operation for one-, two-, three- or four-lamp ballasts. 2 Two-lamp emergency operation for two-, three- or four-lamp ballasts. 3 One-lamp, two-hour emergency operation for two-, three- or four-lamp ballasts. 4 2LP option required for two-lamp emergency operation in fixtures with two or more lamps. 5 All spacings are intended to be guidelines. Results will vary if application deviates from dimensions or assumptions stated below. AF Meets Life Safety Code standard minimum illuminance of 0.1 FC and average illuminance of 1.0 FC. Assumes a 1.0 FC minimum requirement. Assumes 3 T8 lamps in each fixture, 6' wide path of egress and a 9 ceiling height (exception: 18' ceiling on industrials). 7 Assumptions to arrive at these spacings: Open office dimensions/ reflectances: 100 L x 80 W x 9 H with 80/50/20 reflectances. Corridor dimensions/reflectances: 100 L x 8 W x 9 H with 80/50/20 reflectances. Industrial dimensions/reflectances: 200 L x 200 W x18 H with 10/10/10 reflectances. 8 Limited spacing due to 40:1 max-to-min ratio requirement by NFPA

35 Corridor Spacing Performance Data POWER SENTRY BATTERY PACKS Spacing Guidelines GENERAL INFORMATION 43' 1 FC average 0.1 FC minimum POWER SENTRY RECOMMENDED CENTER-TO-CENTER SPACING FOR CORRIDORS 1 ONE FOOTCANDLE AVERAGE SPACING GUIDELINES T8 LENSED TROFFER T8 DIRECT/INDIRECT T8 PARABOLIC PS300QD 24' 18' 21' PSQ500QD 35' 28' 32' PS600QD 43' 34' 40' PS1400QD 57' 59' 53' 9' PS600QD Recommended Spacing Fluorescent battery pack: PS600QD 6' Fluorescent fixture: Lensed troffer Lamp type: F32T8 Open Office Spacing 45' 1 FC average 0.1 FC minimum POWER SENTRY RECOMMENDED CENTER-TO-CENTER SPACING FOR OPEN OFFICES 2 ONE FOOTCANDLE AVERAGE SPACING GUIDELINES T8 LENSED TROFFER T8 DIRECT/INDIRECT T8 PARABOLIC PS300QD 16' 13' 17' PSQ500QD 29' 21' 27' PS600QD 35' 26' 34' PS1400QD 47' 47' 45' PS1400QD Recommended Spacing Fluorescent battery pack: PS1400QD Fluorescent fixture: 2 x 4 parabolic Lamp type: F32T8 6' 9' 1 Meets Life Safety Code standard minimum illuminance of 0.1 FC and average illuminance of 1.0 FC. Assumes three T8 lamps in each fixture, 8'W X 100' L corridor, ceiling height of 9' and reflectances of 80/50/20. 2 Meets Life Safety Code standard minimum illuminance of 0.1 FC and average illuminance of 1.0 FC. Assumes three T8 lamps in each fixture, 100'W X 100'L open office, ceiling height of 9' and reflectances of 80/50/

36 GENERAL INFORMATION EMERGENCY UNITS Spacing Guidelines for Sealed-Beam Lamps and Composite Lamps SEALED-BEAM LAMPS SPACING GUIDELINES 2 7.5' MOUNTING HEIGHT 12' MOUNTING HEIGHT 14' MOUNTING HEIGHT 16' MOUNTING HEIGHT 18' MOUNTING HEIGHT 20' MOUNTING HEIGHT Performance Data 25' MOUNTING HEIGHT CATALOG LAMP 1FC 1FC 1FC 1FC 1FC 1FC 1FC VOLTS WATTS LAMP TYPE LUMENS BEAM H X V NUMBER NUMBER AVG. MIN. AVG. MIN. AVG. MIN. AVG. MIN. AVG. MIN. AVG. MIN. AVG. MIN. N0806S 6 8 Incandescent x N1206S 6 12 Incandescent x N1806S 6 18 Incandescent x N2506S 6 25 Incandescent x N1212S Incandescent x N1812S Incandescent x N2512S Incandescent x N3512S Incandescent Trapezoid N5012S Incandescent PAR36NSP Spot N5024S Incandescent x H0606S 6 6 Halogen 110 H x H0806S 6 8 Halogen 150 H x H1206S 6 12 Halogen 263 H x H2006S 6 20 Halogen 400 H x H0812S 12 8 Halogen 150 H x H1212S Halogen 263 H x H3512S Halogen 706 H x H5012S Halogen 940 H x MR24 LAMP HEAD RECOMMENDED CENTER-TO-CENTER SPACING CATALOG LAMP NUMBER VOLTAGE/ WATTAGE QUANTUM UNIT 7.5' MOUNTING HEIGHT 10' MOUNTING HEIGHT 12' MOUNTING HEIGHT 16' MOUNTING HEIGHT 20' MOUNTING HEIGHT K0606 6V/5.4W ELM2 3 25' N/A N/A N/A N/A K0906 6V/9W ELM618 3, ELM27 3, ELM ' 31' 29' 27' 23' K V/9W ELM1254 3, ELM ' 33' 30' 29' 28' H1206 6V/12W ELM627, ELM654 N/A 29' N/A 22' N/A H V/12W ELM1254, ELM1272 N/A 31' 33' 39' 41' H2006 6V/20W ELM654 N/A 35' 37' 52' 49' H V/20W ELM1254, ELM1272 N/A 43' 41' 38' 32' 1 Meets Life Safety Code standard minimum illuminance of 0.1 FC, average illuminance of 1.0 FC, and 40:1 max/min ratio. Assumes 6'-wide path of egress in 15'-wide aisle of 200' X 200', open warehouse with reflectances of 10/10/10. 2 For Indura spacing guidelines, see pages 477 and Standard lamp for this unit

37 INDURA COMPOSITE LAMPS INDURA 4X COMPOSITE LAMPS CATALOG NUMBER VOLTS WATTS LAMP TYPE LUMENS BEAM INDURA/INDURA 4X SPACING GUIDELINES 12' MOUNTING HEIGHT 14' MOUNTING HEIGHT 16' MOUNTING HEIGHT 18' MOUNTING HEIGHT 20' MOUNTING HEIGHT Performance Data INDURA INDURA 4X Spacing Guidelines for Composite Lamps 24' MOUNTING HEIGHT 1FC 1FC 1FC 1FC 1FC 1FC AVG. MIN. AVG. MIN. AVG. MIN. AVG. MIN. AVG. MIN. AVG. MIN. K Krypton 180 Medium K Krypton 190 Medium H Halogen 238 Spot H Halogen 238 Medium H Halogen 238 Flood H Halogen 402 Spot H Halogen 402 Medium H Halogen 402 Flood H Halogen 276 Spot H Halogen 276 Medium H Halogen 276 Flood H Halogen 314 Spot H Halogen 314 Medium H Halogen 314 Flood H Halogen 300 Spot H Halogen 300 Medium H Halogen 300 Flood K Krypton 180 Medium K Krypton 190 Medium H Halogen 238 Spot H Halogen 238 Medium H Halogen 238 Flood H Halogen 402 Spot H Halogen 402 Medium H Halogen 402 Flood H Halogen 276 Spot H Halogen 276 Medium H Halogen 276 Flood H Halogen 314 Spot H Halogen 314 Medium H Halogen 314 Flood H Halogen 300 Spot H Halogen 300 Medium H Halogen 300 Flood All spacings are intended to be guidelines and meet Life Safety Code standard minimum illuminance of 0.1 FC, average illuminance of 1.0 FC and 40:1 max/min ratio. The 1 FC minimum fixture spacing meets a 0.1 FC minimum illuminance, 1.0 FC average illuminance and a 40:1 max/min ratio. Results will vary if application deviates from dimensions or assumptions stated. Spacing guidelines assume 6'-wide path of egress in 15'-wide aisle of 200'x200'x30' open warehouse with reflectances of 10/10/10. GENERAL INFORMATION

38 Performance Data GENERAL INFORMATION QUANTUM Spacing Guidelines As Lithonia Lighting continues to improve the performance of its emergency lighting products, we also continue to improve the manner in which we communicate our products' performance. Instead of relying on lamp iso-footcandle diagrams to compare one source to the next, we now perform point-by-point illuminance calculations to more accurately depict how our products will perform in real commercial or industrial applications. Point-by-point calculations depict illuminance coverage of an individual unit and/or multiple units in a space. Graphical representation of point-by-point for both a 3' and 6' path of egress are highlighted throughout the next few pages. In the graphical representation, the rectangle depicts the area where an average of one footcandle (FC) is maintained. The surrounding curve represents the minimum 0.1 FC isocontour along the floor. The coverage of an individual unit, as well as the maximum spacing that can be achieved with multiple units is depicted in feet. The footnotes detail all the relevant information necessary to replicate each layout using your own lighting analysis software and IESNA format photometrics. Quantum ELM2 MR24 Lamp Head 0.1 FC min. 1 FC average 0.1 FC min. 1 FC average ELM2 Peformance Advantage Single-Unit Coverage 1 average illuminance of 1.0 FC over a distance of 24' on a 3' path of egress and 18' on a 6' path of egress. 24' Example of single ELM2 unit illuminating a 3 path of egress. 3' 18' Example of single ELM2 unit illuminating a 6 path of egress. 6' 25' 20' 1 FC average 1 FC average ELM2 Peformance Advantage Multiple-Unit Coverage FC min. 0.1 FC min. center-to-center spacing on a 3' path of egress and 20' center-tocenter spacing on a 6' path of egress. Example of multiple ELM2 units in a row illuminating a 3 path of egress. 3' Example of multiple ELM2 units in a row illuminating a 6 path of egress. 6' High-Capacity Quantum (ELM6 & ELM12) MR24 Lamp Head 52' 10' 31' 12' 33' 16' 3' ELM6 Performance Advantage 2 1 FC average 0.1 FC minimum ELM12 Performance Advantage 2 1 Meets Life Safety Code standard minimum illuminance of 0.1 FC and average illuminance of 1.0 FC. Assumes open space with no obstructions, mounting height: 7.5, ceiling height: 9, and reflectances: 80/50/20. Analysis based on independently tested photometrics. 3' ELM6 Halogen Performance Advantage 2 2 Meets Life Safety Code standard minimum illuminance of 0.1 FC and average illuminance of 1.0 FC. Assumes open space with no obstructions, 3-foot-wide path of egress, and reflectances of 80/50/20. 3'

39 0.1 FC min. 1 FC average 26' 3' 0.1 FC min. 1 FC average 21' 6' Performance Data AFFINITY Spacing Guidelines AFFINITY RECOMMENDED CENTER-TO-CENTER SPACING 1,2 XENON LAMP PATH OF EGRESS 3'-WIDE PATH OF EGRESS 6'-WIDE Center-to-center spacing 26' 21' GENERAL INFORMATION Example of multiple units in a row illuminating a 3 path of egress. Example of multiple units in a row illuminating a 6 path of egress. 1 FC average 0.1 FC minimum 1 FC average 0.1 FC min. 6' 3' 28' 20' 8.5' 1 Meets Life Safety Code standard minimum illuminance of 0.1 FC and average illuminance of 1.0 FC. Assumes open space with no obstructions, mounting height 8.5', ceiling height 9', and reflectances: 80/50/20. 2 All spacings are intended to be guidelines. Results will vary if application deviates from dimensions or assumptions stated. Affinity Ext Fwd Performance Data VELARE Spacing Guidelines 65' VELARE RECOMMENDED CENTER-TO-CENTER SPACING 1,2 LAMP TYPE 10' CEILING HEIGHT 12' CEILING HEIGHT 16' CEILING HEIGHT 20' CEILING HEIGHT H ' 17' 16' 16' H ' 36' 34' 34' H ' 65' 58' 64' H ' 70' 70' 70' H ' 140' 134' 140' 12' 6' Example of Velare - 35W MR16 at a 12' ceiling height 1 Meets Life Safety Code standard minimum illuminance of 0.1 FC and average illuminance of 1.0 FC. Assumes fixture is ceiling mounted in a 200'Wx200'L open area and reflectances of 80/50/20. 2 All spacings are intended to be guidelines. Results will vary if application deviates from dimensions or assumptions stated

40 GENERAL INFORMATION INDURA INDURA 4X Spacing Guidelines Performance Data 25.5' 41' Example of multiple IND units in a row illuminating a 6' path of egress. 6' Example of multiple IND units in a row illuminating a 6' path of egress. 6' IND K0906 Performance Advantage 1,2 IND H2006 Performance Advantage 1,2 26' 80' Example of multiple IND units in a row illuminating a 3' path of egress. 3' Example of multiple IND units in a row illuminating a 6' path of egress. 6' IND K0912 Performance Advantage 1,2 IND H5012S Performance Advantage 1,2 1 FC average 0.1 FC minimum 1 Meets Life Safety Code standard minimum illuminance of 0.1 FC and average illuminance of 1.0 FC. Assumes space of 200'L X 200'W X 30'H, mounting height: 12', ceiling height 30', and reflectances 10/10/10. Analysis based on independently tested photometrics. 2 See page 477 for recommended spacing chart

41 SECTION 1006 MEANS OF EGRESS ILLUMINATION Illumination required. The means of egress, including the exit discharge, shall be illuminated at all times the building space served by the means of egress is occupied. Exceptions: (1) Occupancies in Group U. (2) Aisle accessways in Group A. (3) Dwelling units and sleeping units in Groups R-1, R-2 and R-3. (4) Sleeping units of Group I occupancies Illumination level. The means of egress illumination level shall not be less than 1 foot-candle (11 lux) at the walking surface. Exception: For auditoriums, theaters, concert or opera halls and similar assembly occupancies, the illumination at the walking surface is permitted to be reduced during performances to not less than 0.2 foot-candle (2.15 lux), provided that the required illumination is automatically restored upon activation of a premises' fire alarm system where such system is provided Illumination emergency power. The power supply for means of egress illumination shall normally be provided by the premises' electrical supply. In the event of power supply failure, an emergency electrical system shall automatically illuminate all of the following areas: (1) Aisles and unenclosed egress stairways in rooms and spaces which require two or more means of egress. (2) Corridors, exit enclosures and exit passageways located in buildings required to have two or more exits. (3) Exterior egress components at other than their levels of exit discharge until exit discharge is accomplished for buildings required to have two or more exits. (4) Interior exit discharge elements, as permitted in Section , in buildings required to have two or more exits. (5) Exterior landings as required by Section for exit discharge doorways in buildings required to have two or more exits. The emergency power system shall provide power for a duration of not less than 90 minutes and shall consist of storage batteries, unit equipment or an on-site generator. The installation of the emergency power system shall be in accordance with Chapter Performance of system. Emergency lighting facilities shall be arranged to provide initial illumination that is at least an average of 1 foot-candle (11 lux) and a minimum at any point of 0.1 foot-candle (1 lux) measured along the path of egress at floor level. Illumination levels shall be permitted to decline to 0.6 foot-candle (6 lux) average and a minimum at any point of 0.06 foot-candle (0.6 lux) at the end of the emergency lighting time duration. A maximum-to-minimum illumination uniformity ratio of 40 to 1 shall not be exceeded. SECTION 1011 EXIT SIGNS Where required. Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress travel. The path of egress travel to exits and within exits shall be marked by readily visible exit signs to clearly indicate the direction of egress travel in cases where the exit or the path of egress travel is not immediately visible to the occupants. Intervening means of egress doors within exits shall be marked by exit signs. Exit sign placement shall be such that no point in an exit access corridor or exit passageway is more than 100 feet (30480 mm) or the listed viewing distance for the sign, whichever is less, from the nearest visible exit sign. Exceptions: (1) Exit signs are not required in rooms or areas that require only one exit or exit access. (2) Main exterior exit doors or gates that are obviously and clearly identifiable as exits need not have exit signs where approved by the building official. (3) Exit signs are not required in occupancies in Group U and individual sleeping units or dwelling units in Group R-1, R-2 or R-3. (4) Exit signs are not required in dayrooms, sleeping rooms or dormitories in occupancies in Group I-3. (5) In occupancies in Groups A-4 and A-5, exit signs are not required on the seating side of vomitories or openings into seating areas where exit signs are provided in the concourse that are readily apparent from the vomitories. Egress lighting is provided to identify each vomitory or opening within the seating area in an emergency Illumination. Exit signs shall be internally or externally illuminated. Exception: Tactile signs required by Section need not be provided with illumination Tactile exit signs. A tactile sign stating EXIT and complying with ICC A117.1 shall be provided adjacent to each door to an egress stairway, an exit ramp, an exit passageway and the exit discharge Internally illuminated exit signs. Electrically powered, self-luminous and photoluminescent exit signs shall be listed and labeled in accordance with UL 924 and shall be Safety Codes 2009 INTERNATIONAL BUILDING CODE installed in accordance with the manufacturer s instructions and Chapter 27. Exit signs shall be illuminated at all times Externally illuminated exit signs. Externally illuminated exit signs shall comply with Sections through Graphics. Every exit sign and directional exit sign shall have plainly legible letters not less than 6 inches (152 mm) high with the principal strokes of the letters not less than 3/4 inch (19.1 mm) wide. The word EXIT shall have letters having a width not less than 2 inches (51 mm) wide, except the letter I, and the minimum spacing between letters shall not be less than 3/8 inch (9.5 mm). Signs larger than the minimum established in this section shall have letter widths, strokes and spacing in proportion to their height. The word EXIT shall be in high contrast with the background and shall be clearly discernible when the means of exit sign illumination is or is not energized. If a chevron directional indicator is provided as part of the exit sign, the construction shall be such that the chevron directional indicator cannot be readily changed Exit sign illumination. The face of an exit sign illuminated from an external source shall have an intensity of not less than 5 foot-candles (54 lux) Power source. Exit signs shall be illuminated at all times. To ensure continued illumination for a duration of not less than 90 minutes in case of primary power loss, the sign illumination means shall be connected to an emergency power system provided from storage batteries, unit equipment or an on-site generator. The installation of the emergency power system shall be in accordance with Chapter 27. Exception: Approved exit sign illumination means that provide continuous illumination independent of external power sources for a duration of not less than 90 minutes, in case of primary power loss, are not required to be connected to an emergency electrical system. Portions of this publication reproduce content from the 2009 International Building Code. International Code Council, Inc., Country Club Hills, Illinois. Reproduced with permission. All rights reserved. GENERAL INFORMATION

42 GENERAL INFORMATION NFPA 101 LIFE SAFETY CODE 2009 Reprinted with permission from NFPA 101, Life Safety Code, Copyright 2009, National Fire Protection Association, Quincy, MA. 7.8 Illumination of Means of Egress General * Illumination of means of egress shall be provided in accordance with Section 7.8 for every building and structure where required in Chapters 11 through 43. For the purposes of this requirement, exit access shall include only designated stairs, aisles, corridors, ramps, escalators, and passageways leading to an exit. For the purposes of this requirement, exit discharge shall include only designated stairs, aisles, corridors, ramps, escalators, walkways, and exit passageways leading to a public way Illumination of means of egress shall be continuous during the time that the conditions of occupancy require that the means of egress be available for use, unless otherwise provided in Artificial lighting shall be employed at such locations and for such periods of time as are necessary to maintain the illumination to the minimum criteria values herein specified Automatic, motion sensor-type lighting switches shall be permitted within the means of egress, provided that the switch controllers are equipped for fail-safe operation, the illumination timers are set for a minimum 15-minute duration, and the motion sensor is activated by any occupant movement in the area served by the lighting units * The floors and other walking surfaces within an exit and within the portions of the exit access and exit discharge designated in shall be illuminated as follows: (1) During conditions of stair use, the minimum illumination for new stairs shall be at least 10 ft-candle (108 lux), measured at the walking surfaces. (2) The minimum illumination for floors and walking surfaces, other than new stairs during conditions of stair use, shall be to values of at least 1 ft-candle (10.8 lux), measured at the floor. (3) In assembly occupancies, the illumination of the walking surfaces of exit access shall be at least 0.2 ft-candle (2.2 lux) during periods of performances or projections involving directed light. (4)*The minimum illumination requirements shall not apply where operations or processes require low lighting levels * Required illumination shall be arranged so that the failure of any single lighting unit does not result in an illumination level of less than 0.2 ft-candle (2.2 lux) in any designated area The equipment or units installed to meet the requirements of Section 7.10 also shall be permitted to serve the function of illumination of means of egress, provided that all requirements of Section 7.8 for such illumination are met Sources of Illumination * Illumination of means of egress shall be from a source considered reliable by the authority having jurisdiction Battery-operated electric lights and other types of portable lamps or lanterns shall not be used for primary illumination of means of egress. Battery-operated electric lights shall be permitted to be used as an emergency source to the extent permitted under Section Emergency Lighting General * Emergency lighting facilities for means of egress shall be provided in accordance with Section 7.9 for the following: (1) Buildings or structures where required in Chapters 11 through 43 (2) Underground and limited access structures as addressed in Section 11.7 (3) High-rise buildings as required by other sections of this Code (4) Doors equipped with delayed-egress locks (5) Stair shaft and vestibule of smokeproof enclosures, for which the following also apply: (a) The stair shaft and vestibule shall be permitted to include a standby generator that is installed for the smokeproof enclosure mechanical ventilation equipment. (b) The standby generator shall be permitted to be used for the stair shaft and vestibule emergency lighting power supply. (6) New access-controlled egress doors in accordance with For the purposes of , exit access shall include only designated stairs, aisles, corridors, ramps, escalators, and passageways leading to an exit. For the purposes of , exit discharge shall include only designated stairs, ramps, aisles, walkways, and escalators leading to a public way Where maintenance of illumination depends on changing from one energy source to another, a delay of not more than 10 seconds shall be permitted Performance of System * Emergency illumination shall be provided for not less than 1-1/2 hours in the event of failure of normal lighting. Emergency lighting facilities shall be arranged to provide initial illumination that is not less than an average of 1 ft-candle (10.8 lux) and, at any point, not less than 0.1 ft-candle (1.1 lux), measured along the path of egress at floor level. Illumination levels shall be permitted to decline to not less than an average of 0.6 ft-candle (6.5 lux) and, at any point, not less than 0.06 ft-candle (0.65 lux) at the end of the 1-1/2 hours. A maximum-to-minimum illumination uniformity ratio of 40 to 1 shall not be exceeded New emergency power systems for emergency lighting shall be at least Type 10, Class 1.5, Level 1, in accordance with NFPA110, Standard for Emergency and Standby Power Systems * The emergency lighting system shall be arranged to provide the required illumination automatically in the event of any interruption of normal lighting due to any of the following: (1) Failure of a public utility or other outside electrical power supply (2) Opening of a circuit breaker or fuse (3) Manual act(s), including accidental opening of a switch controlling normal lighting facilities Emergency generators providing power to emergency lighting systems shall be installed, tested, and maintained in accordance with NFPA 110, Standard for Emergency and Standby Power Systems. Stored electrical energy systems, where required in this Code, other than battery systems for emergency luminaires in accordance with , shall be installed and tested in accordance with NFPA 111, Standard on Stored Electrical Energy Emergency and Standby Power Systems Unit equipment and battery systems for emergency luminaires shall be listed to UL 924, Standard for Emergency Lighting and Power Equipment * Existing battery-operated emergency lights shall use only reliable types of rechargeable batteries provided with suitable facilities for maintaining them in properly charged condition. Batteries used in such lights or units shall be approved for their intended use and shall comply with NFPA70, National Electrical Code The emergency lighting system shall be either continuously in operation or shall be capable of repeated automatic operation without manual intervention Periodic Testing of Emergency Lighting Equipment Required emergency lighting systems shall be tested in accordance with one of the three options offered by , , or Testing of required emergency lighting systems shall be permitted to be conducted as follows: (1) Functional testing shall be conducted monthly with a minimum of 3 weeks and a maximum of 5 weeks between tests, for not less than 30 seconds, except as otherwise permitted by (2). (2) The test interval shall be permitted to extend beyond 30 days with the approval of the authority having jurisdiction. (3) Functional testing shall be conducted annually for not less than 1-1/2 hours if the emergency Safety Codes lighting system is battery powered. (4) The emergency lighting equipment shall be fully operational for the duration of the tests required by (1) and (2). (5) Written records of visual inspections and tests shall be kept by the owner for inspection by the authority having jurisdiction Testing of required emergency lighting systems shall be permitted to be conducted as follows: (1) Self-testing/self-diagnotic battery-operated emergency lighting equipment shall be provided. (2)Not less than once every 30 days, self-testing/self-diagnostic battery-operated emergency lighting equipment shall automatically perform a test with a duration of a minimum of 30 seconds and a diagnostic routine. (3) Self-testing/self-diagnostic battery-operated emergency lighting equipment shall indicate failures by a status indicator. (4) A visual inspection shall be performed at intervals not exceeding 30 days. (5) Functional testing shall be conducted annually for not less than 1-1/2 hours. (6) Self-testing/selfdiagnostic battery-operated emergency lighting equipment shall be fully operational for the duration of the 1-1/2 hour test. (7) Written records of visual inspections and tests shall be kept by the owner for inspection by the authority having jurisdiction Testing of required emergency lighting systems shall be permitted to be conducted as follows: (1) Computer-based, self-testing/self-diagnostic battery operated emergency lighting equipment shall be provided. (2) The emergency lighting equipment shall automatically perform not less than once every 30 days a test for not less than 30 seconds and a diagnostic routine. (3) The emergency lighting equipment shall automatically perform annually a test for not less than 1-1/2 hours. (4) The emergency lighting equipment shall be fully operational for the duration of the tests required by (2) and (3). (5) The computer-based system shall be capable of providing a report of the history of tests and failures at all times Marking of Means of Egress General Where Required. Means of egress shall be marked in accordance with Section 7.10 where required in Chapters 11 through Exits * Exits, other than main exterior exit doors that obviously and clearly are identifiable as exits, shall be marked by an approved sign that is readily visible from any direction of exit access * Horizontal components of the egress path within an exit enclosure shall be marked by approved exit or directional exit signs where the continuation of the path of egress is not obvious Exit Door Tactile Signage. Tactile signage shall be provided to meet the following criteria, unless otherwise provided in : (1) Tactile signage shall be located at each exit door requiring an exit sign. (2) Tactile signage shall read as follows: EXIT. (3) Tactile signage shall comply with ICC/ANSI A117.1, American National Standard for Accessible and Usable Buildings and Facilities Existing Exemption. The requirements of shall not apply to existing buildings, provided that the occupancy classification does not change Exit Access Access to exits shall be marked by approved, readily visible signs in all cases where the exit or way to reach the exit is not readily apparent to the occupants * New sign placement shall be such that no point in an exit access corridor is in excess of the rated viewing distance or 100 ft (30 m), whichever is less, from the nearest sign * Floor Proximity Exit Signs. Where floor proximity exit signs are required in Chapters 11 through 43, such signs shall comply with , , , and for externally illuminated signs and for internally illuminated signs. Such signs shall be

43 located near the floor level in addition to those signs required for doors or corridors. The bottom of the sign shall be not less than 6 in. (150 mm), but not more than 18 in. (455 mm), above the floor. For exit doors, the sign shall be mounted on the door or adjacent to the door, with the nearest edge of the sign within 4 in. (100 mm) of the door frame * Floor Proximity Egress Path Marking. Where floor proximity egress path marking is required in Chapters 11 through 43, an approved floor proximity egress path marking system that is internally illuminated shall be installed within 18 in. (455 mm) of the floor. Floor proximity egress path marking systems shall be listed in accordance with ANSI/UL 1994, Standard for Luminous Egress Path Marking Systems. The system shall provide a visible delineation of the path of travel along the designated exit access and shall be essentially continuous, except as interrupted by doorways, hallways, corridors, or other such architectural features. The system shall operate continuously or at any time the building fire alarm system is activated. The activation, duration, and continuity of operation of the system shall be in accordance with The system shall be maintained in accordance with the product manufacturing listing * Visibility. Every sign required in Section 7.10 shall be located and of such size, distinctive color, and design that it is readily visible and shall provide contrast with decorations, interior finish, or other signs. No decorations, furnishings, or equipment that impairs visibility of a sign shall be permitted. No brightly illuminated sign (for other than exit purposes), display, or object in or near the line of vision of the required exit sign that could detract attention from the exit sign shall be permitted Mounting Location. The bottom of new egress markings shall be located at a vertical distance of not more than 6 ft 8 in. (2030 mm) above the top edge of the egress opening intended for designation by that marking. Egress markings shall be located at a horizontal distance of not more than the required width of the egress opening, as measured from the edge of the egress opening intended for designation by that marking to the nearest edge of the marking Directional Signs * A sign complying with with a directional indicator showing the direction of travel shall be placed in every location where the direction of travel to reach the nearest exit is not apparent Directional exit signs shall be provided within horizontal components of the egress path within exit enclosures as required by * Sign Legend Signs required by and shall read as follows in plainly legible letters, or other appropriate wording shall be used: EXIT * Where approved by the authority having jurisdiction, pictograms in compliance with NFPA 170, Standard for Fire Safety and Emergency Symbols, shall be permitted * Power Source. Where emergency lighting facilities are required by the applicable provisions of Chapter 11 through Chapter 42 for individual occupancies, the signs, other than approved selfluminous signs and listed photoluminescent signs in accordance with , shall be illuminated by the emergency lighting facilities. The level of illumination of the signs shall be in accordance with or for the required emergency lighting duration as specified in However, the level of illumination shall be permitted to decline to 60 percent at the end of the emergency lighting duration Illumination of Signs * General. Every sign required by , , or , other than where operations or processes require low lighting levels, shall be suitably illuminated by a reliable light source. Externally and internally illuminated signs shall be legible in both the normal and emergency lighting mode * Continuous Illumination Every sign required to be illuminated by , , and shall be continuously illuminated as required under the provisions of Section 7.8, unless otherwise provided in * Illumination for signs shall be permitted to flash on and off upon activation of the fire alarm system Externally Illuminated Signs * Size of Signs Externally illuminated signs required by and , other than approved existing signs, unless otherwise provided in , shall read EXIT or shall use other appropriate wording in plainly legible letters sized as follows: (1) For new signs, the letters shall be not less than 6 in. (150 mm) high, with the principal strokes of letters not less than 3/4 in. (19 mm) wide. (2) For existing signs, the required wording shall be permitted to be in plainly legible letters not less than 4 in. (100 mm) high. (3) The word EXIT shall be in letters of a width not less than 2 in. (51 mm), except the letter I, and the minimum spacing between letters shall be not less than 3/8 in. (9.5 mm). (4) Sign legend elements larger than the minimum established in (1) through (3) shall use letter widths, strokes, and spacing in proportion to their height The requirements of shall not apply to marking required by and * Size and Location of Directional Indicator Directional indicators, unless otherwise provided in , shall comply with the following: (1) The directional indicator shall be located outside of the EXIT legend, not less than 3/8 in. (9.5 mm) from any letter. (2) The directional indicator shall be of a chevron type, as shown in Figure (3) The directional indicator shall be identifiable as a directional indicator at a distance of 40 ft (12 m). (4) A directional indicator larger than the minimum established for compliance with (3) shall be proportionately increased in height, width, and stroke. (5) The directional indicator shall be located at the end of the sign for the direction indicated. Safety Codes provisions of this Code, shall comply with the visual character requirements of ICC/ANSI A117.1, American National Standard for Accessible and Usable Buildings and Facilities * No Exit Any door, passage, or stairway that is neither an exit nor a way of exit access and that is located or arranged so that it is likely to be mistaken for an exit shall be identified by a sign that reads as follows: NO EXIT The NO EXIT sign shall have the word NO in letters 2 in. (51 mm) high, with a stroke width of 3/8 in. (9.5 mm), and the word EXIT in letters 1 in. (25 mm) high, with the word EXIT below the word NO, unless such sign is an approved existing sign Elevator Signs. Elevators that are a part of a means of egress (see ) shall have the following signs with a minimum letter height of 5/8 in. (16 mm) posted in every elevator lobby: (1)*Signs that indicate that the elevator can be used for egress, including any restrictions on use (2)*Signs that indicate the operational status of elevators * Evacuation Diagram. Where a posted floor evacuation diagram is required in Chapters 11 through 43, floor evacuation diagrams reflecting the actual floor arrangement and exit locations shall be posted and oriented in a location and manner acceptable to the authority having jurisdiction Testing and Maintenance Inspection. Exit signs shall be visually inspected for operation of the illumination sources at intervals not to exceed 30 days or shall be periodically monitored in accordance with Testing. Exit signs connected to or provided with a battery-operated emergency illumination source, where required in , shall be tested and maintained in accordance with GENERAL INFORMATION FIGURE Chevron-Type Indicator The requirements of shall not apply to approved existing signs * Level of Illumination. Externally illuminated signs shall be illuminated by not less than 5 ft-candles (54 lux) at the illuminated surface and shall have a contrast ratio of not less than Internally Illuminated Signs Listing. Internally illuminated signs shall be listed in accordance with UL 924, Standard for Emergency Lighting and Power Equipment, unless they meet one of the following criteria: (1) They are approved existing signs. (2) They are existing signs having the required wording in legible letters not less than 4 in. (100 mm) high. (3) They are signs that are in accordance with and * Photoluminescent Signs. The face of a photoluminescent sign shall be continually illuminated while the building is occupied. The illumination levels on the face of the photoluminescent sign shall be in accordance with its listing. The charging illumination shall be a reliable light source as determined by the authority having jurisdiction. The charging light source shall be of a type specified in the product markings Special Signs Sign Illumination Where required by other provisions of this Code, special signs shall be illuminated in accordance with , , and Where emergency lighting facilities are required by the applicable provisions of Chapter 12 through Chapter 43, the required illumination of special signs shall additionally be provided under emergency lighting conditions Characters. Special signs, where required by other

44 GENERAL INFORMATION NFPA 70 NATIONAL ELECTRICAL CODE 2008 Reprinted with permission from NFPA 70, National Electrical Code, Copyright 2008, National Fire Protection Association, Quincy, MA. This reprinted material is not the complete and official position of the NFPA on the referenced subject, which is represented only by the standard in its entirety. ARTICLE 700 Emergency Systems I. General Scope The provisions of this article apply to the electrical safety of the installation, operation, and maintenance of emergency systems consisting of circuits and equipment intended to supply, distribute, and control electricity for illumination, power, or both, to required facilities when the normal electrical supply or system is interrupted. Emergency systems are those systems legally required and classed as emergency by municipal, state, federal, or other codes, or by any governmental agency having jurisdiction. These systems are intended to automatically supply illumination, power, or both, to designated areas and equipment in the event of failure of the normal supply or in the event of accident to elements of a system intended to supply, distribute, and control power and illumination essential for safety to human life. FPN No. 1: For further information regarding wiring and installation of emergency systems in health care facilities, see Article 517. FPN No. 2: For further information regarding performance and maintenance of emergency systems in health care facilities, see NFPA , Standard for Health Care Facilities. FPN No. 3: Emergency systems are generally installed in places of assembly where artificial illumination is required for safe exiting and for panic control in buildings subject to occupancy by large numbers of persons, such as hotels, theaters, sports arenas, health care facilities, and similar institutions. Emergency systems may also provide power for such functions as ventilation where essential to maintain life, fire detection and alarm systems, elevators, fire pumps, public safety communications systems, industrial processes where current interruption would produce serious life safety or health hazards, and similar functions. FPN No. 4: For specification of locations where emergency lighting is considered essential to life safety, see NFPA , Life Safety Code. FPN No. 5: For further information regarding performance of emergency and standby power systems, see NFPA , Standard for Emergency and Standby Power Systems Signs (A) Emergency Sources A sign shall be placed at the service entrance equipment, indicating type and location of on-site emergency power sources. Exception: A sign shall not be required for individual unit equipment as specified in (F). (B) Grounding Where the grounded circuit conductor connected to the emergency source is connected to a grounding electrode conductor at a location remote from the emergency source, there shall be a sign at the grounding location that shall identify all emergency and normal sources connected at that location. II. Circuit Wiring Wiring, Emergency System (A) Identification All boxes and enclosures (including transfer switches, generators, and power panels) for emergency circuits shall be permanently marked so they will be readily identified as a component of an emergency circuit or system. (B) Wiring Wiring of two or more emergency circuits supplied from the same source shall be permitted in the same raceway, cable, box, or cabinet. Wiring from an emergency source or emergency source distribution overcurrent protection to emergency loads shall be kept entirely independent of all other wiring and equipment, unless otherwise permitted in (1) through (4): (1)Wiring from the normal power source located in transfer equipment enclosures (2)Wiring supplied from two sources in exit or emergency luminaires (lighting fixtures) (3)Wiring from two sources in a common junction box, attached to exit or emergency luminaires (lighting fixtures) (4)Wiring within a common junction box attached to unit equipment, containing only the branch circuit supplying the unit equipment and the emergency circuit supplied by the unit equipment (5)Wiring from an emergency source to supply any combination of emergency, legally required, or optional loads in accordance with (a), (b), and (c): (a)from separate vertical switchboard sections, with or without a common bus, or from individual disconnects mounted in separate enclosures (b)the common bus or separate sections of the switchboard or the individual enclosures shall be permitted to be supplied by single or multiple feeders without overcurrent protection at the source Exception to (5)(b): Overcurrent protection shall be permitted at the source or for the equipment, provided the overcurrent protection is selectively coordinated with the downstream overcurrent protection. (c)legally required and optional standby circuits shall not originate from the same vertical switchboard section, panelboard enclosure, or individual disconnect enclosure as emergency circuits (C) Wiring Design and Location Emergency wiring circuits shall be designed and located so as to minimize the hazards that might cause failure due to flooding, fire, icing, vandalism, and other adverse conditions. (D) Fire Protection Emergency systems shall meet the additional requirements in 700.9(D)(1) and (D)(2) assembly occupancies for not less than 1000 persons or in buildings above 23 m (75 ft) in height with any of the following occupancy classes: assembly, educational, residential, detention and correctional, business, and mercantile. (1) Feeder-Circuit Wiring Feeder-circuit wiring shall meet one of the following conditions: (1) Be installed in spaces or areas that are fully protected by an approved automatic fire suppression system (2) Be a listed electrical circuit protective system with a minimum 1-hour fire rating FPN: UL guide information for electrical circuit protection systems (FHIT) contains information on proper installation requirements to maintain the fire rating. (3) Be protected by a listed thermal barrier system for electrical system components (4) Be protected by a listed fire-rated assembly that has a minimum Safety Codes fire rating of 1 hour and contains only emergency wiring circuits (5) Be embedded in not less than 50 mm (2 in.) of concrete (6) Be a cable listed to maintain circuit integrity for not less than 1 hour when installed in accordance with the listing requirements (2) Feeder-Circuit Equipment Equipment for feeder circuits (including transfer switches, transformers, and panelboards) shall be located either in spaces fully protected by approved automatic fire suppression systems (including sprinklers, carbon dioxide systems) or in spaces with a 1-hour fire resistance rating. FPN: For the definition of occupancy classification, see Section 6.1 of NFPA , Life Safety Code. (3) Generator Control Wiring Control conductors installed between the transfer equipment and the emergency generator shall be kept entirely independent of all other wiring and shall meet the conditions of 700.9(D)(1). V. Emergency System Circuits for Lighting and Power Loads on Emergency Branch Circuits No appliances and no lamps, other than those specified as required for emergency use, shall be supplied by emergency lighting circuits Emergency Illumination Emergency illumination shall include all required means of egress lighting, illuminated exit signs, and all other lights specified as necessary to provide required illumination. Emergency lighting systems shall be designed and installed so that the failure of any individual lighting element, such as the burning out of a lamp, cannot leave in total darkness any space that requires emergency illumination. Where high-intensity discharge lighting such as high- and lowpressure sodium, mercury vapor, and metal halide is used as the sole source of normal illumination, the emergency lighting system shall be required to operate until normal illumination has been restored. Exception: Alternative means that ensure emergency lighting illumination level is maintained shall be permitted Circuits for Emergency Lighting Branch circuits that supply emergency lighting shall be installed to provide service from a source complying with when the normal supply for lighting is interrupted. Such installations shall provide either of the following: (1)An emergency lighting supply, independent of the general lighting supply, with provisions for automatically transferring the emergency lights upon the event of failure of the general lighting system supply (2)Two or more separate and complete systems with independent power supply, each system providing sufficient current for emergency lighting purposes Unless both systems are used for regular lighting purposes and are both kept lighted, means shall be provided for automatically energizing either system upon failure of the other. Either or both systems shall be permitted to be a part of the general lighting system of the protected occupancy if circuits supplying lights for emergency illumination are installed in accordance with other sections of this article Circuits for Emergency Power For branch circuits that supply equipment classed as emergency, there shall be an emergency supply source to which the load will be transferred automatically upon the failure of the normal supply

45 The following information is provided to assist in planning layouts for emergency lighting systems. The National Electrical Code limits voltage drop to a maximum of 5% of nominal. Thus, circuit runs must be of sufficient size to maintain operating voltage when remote fixtures and/or exit signs are connected to the emergency lighting equipment. The table below shows the length of wire run based on system voltage, wire gauge and total wattage on the run. Formula: As per NEC standards, V D = 2 x L x I x R 1000 Where: L = length of run in feet I = current R = resistance of material at 75 C V D = voltage drop Example 1: A 12V system using a 10-gauge wire will operate four 12W lamps. Total watts on the wire run is 48, length of run from table is 70 feet. Longer Wire Runs If loads are uniformly spaced along circuit path (equal watts, equal distances), lengths in the table can be increased by certain values. Example 2: Remote heads from Example 1 will be uniformly spaced. Multiplier is 1.6 for four fixtures. Maximum permissible length of wire run is 70' x 1.6, or 112'. Number of fixtures: Multiplier: To determine multiplier for six or more fixtures, use the following formula: Number of fixtures = n Multiplier = 2n n+1 Safety Codes VOLTAGE DROP TABLES GENERAL INFORMATION 6V SYSTEM WIRE SIZE TOTAL LENGTH OF WIRE RUN (FEET) WATTS V SYSTEM WIRE SIZE TOTAL LENGTH OF WIRE RUN (FEET) WATTS ,073 1, , , V SYSTEM WIRE SIZE TOTAL LENGTH OF WIRE RUN (FEET) WATTS ,068 1,698 2,701 4,293 6, ,358 2,161 3,435 5, ,132 1,801 2,862 4, ,040 1,668 2,640 4, ,543 2,453 3, ,350 2,146 3, ,200 1,900 3, ,080 1,717 2, ,029 1,635 2, ,431 2, ,360 2, ,140 1, , , , , ,

46 Outdoor Emergency Lighting GENERAL INFORMATION OUTDOOR EMERGENCY LIGHTING Traditional emergency lighting and exit signs have been primarily focused on guiding the interior occupants of a building to the nearest exit in the event of an emergency. Today, an additional emphasis is being placed on getting occupants to and along a path of safety once they are out of the building. While the code is unclear on what constitutes a pathway and the definition of "the means to a public way", local authorities having jurisdiction over code enforcement and compliance have begun to broaden their interpretation of the Life Safety Code to include some elements of outdoor emergency lighting. Lithonia Lighting provides a complete list of solutions for outdoor emergency applications, including both normally on outdoor fixtures that switch to emergency mode when needed, and normally off fixtures designed only to provide emergency lighting. Normally Off (Dedicated) Fixtures The following dedicated normally off fixtures include both standalone emergency lighting units and remote lamp heads. Both offer their own unique advantages. Remote lamp heads offer advantages such as lower initial cost, lower maintenance cost and better aesthetics due to their small size. However, a battery source is required for operation. Stand-alone emergency lighting units come equipped with a battery and can be less expensive if the application requires a small number to meet light levels. STAND-ALONE EMERGENCY LIGHTING UNITS Stand-alone unit equipment also can be used as a power source. FIXTURE DESCRIPTION WET 1 DAMP 2 NEMA 4X 3 COLD WEATHER 4 AFN EXT AFN EXT FWD Architectural die-cast with xenon lamp, standard and forward optics (FWD) option -18 C to 50 C IND IND IND Industrial emergency unit with krypton lamp -40 C to 55 C (ULT option) INDX INDX INDX INDX24100 Industrial NEMA 4X emergency unit with krypton lamp -40 C to 55 C (ULT option) ELM DL ELM2 DL Thermoplastic emergency unit with krypton lamp ELM DL ELM DL High-capacity thermoplastic with krypton lamp = Available REMOTE LAMP HEADS FIXTURE DESCRIPTION WET DAMP NEMA 4X/IP66 COLD WEATHER ELA AFNR Architectural die-cast remote w/ xenon lamp -40 C to 60 C ELA OMC Outdoor mini cylinder die-cast remote w/halogen lamp AFN ELA CL Recessed round outdoor core remote w/halogen lamp ELA OSL ELA NX = Available Recessed outdoor step light w/ halogen lamp Gasketed, wet location remote w/incandenscent or halogen lamp Lithonia Lighting unit equipment or exit signage with additional capacity can be used to power any remote-mounted lamp. These units or exits can be mounted indoors, while leads can be run to the outdoors

47 Outdoor Emergency Lighting Normally On Fixtures Lithonia Lighting building-mounted products are available with several options to provide attractive and efficient outdoor emergency egress lighting solutions. Integral emergency battery packs (ELDW) or operation with a remote battery pack (ELDWR) for use with compact fluorescent lamps, 12V DC lamps (DC12) powered by a remote battery source or 120V AC lamps (EC) on an emergency circuit are all available today. For specific product and technical information, please refer to GENERAL INFORMATION ELDW and ELDWR ELDW Integral battery pack that operates compact fluorescent lamps at a reduced lumen output. ELDWR Remote battery pack ready for compact fluorescent lamps. Battery pack (by others) mounted external to the building-mounted luminaire. Pilot light/test switch mounting plate and additional wiring included to connect with the external battery pack provided separately. LAMP OPTIONS (# OF LAMPS/ WATTAGE) LAMP START TEMP. F ( C) INITIAL ELDW LUMENS GATEWAY VGR1C, VGR2C, VRG4C, VGR5C ELDW ELDWR 5 ARCHITECTURAL SCONCE WSR, WST, WSQ AERIS ASW VGRXC WSR/T/Q ASW 13DTT -5 (-20 ) 350 2/13DTT -5 (-20 ) DTT -5 (-20 ) 475 2/18DTT -5 (-20 ) DTT -5 (-20 ) 600 2/26DTT -5 (-20 ) TRT -5 (-20 ) 450 2/26TRT -5 (-20 ) TRT -5 (-20 ) 575 2/32TRT -5 (-20 ) TRT -5 (-20 ) 750 2/42TRT -5 (-20 ) N/A ASW = Available DC Options The DC option provides an auxiliary emergency socket for either a 20W or 35W, 12V DC bayonet base MR11 lamp for use with separate external 12V emergency power source (provided by others). DC LAMP OPTION SUFFIX 6 (# OF LAMPS/WATTAGE) INITIAL LUMENS (PER LAMP) CONTOUR TWAC ARCHITECTURAL SCONCE WSR, WST, WSQ AERIS ASW 7 DC2012 (1) 20W lamp 350 2DC2012 (2) 20W lamps 350 DC12 (1) 35W lamp 660 2DC12 (2) 35W lamps 660 = Available 1 Direct exposure to rain or water. 2 Subject to moisture; fixture must be mounted under a canopy. 3 NEMA 4X hosedown/dustproof listing. 4 Cold weather listing: -18 to 50 C(AFN); -40 to 60 C (ELA AFNR DB); or -40 to 55 C (IND/INDX). Exit signage with additional capacity also can be used to run remote heads (e.g., Signature with ELA LEHO or LHQM). TWAC 5 Initial ELDWR lamp lumens depends on the battery pack used. Add ELDW or ELDWR to product family catalog number. 6 Add DC option suffix to product family catalog number. 7 Consult factory for wattage and reflector availability. For additional information, visit

ONTENTS LITHONIA EMERGENCY. PSG Exit Signs 422. Architectural Emergency Units 432. Fluorescent Battery Packs 434

ONTENTS LITHONIA EMERGENCY. PSG Exit Signs 422. Architectural Emergency Units 432. Fluorescent Battery Packs 434 Emergency Systems Lithonia Emergency Systems manufactures a comprehensive selection of exit signs, emergency lighting units, fluorescent battery packs and emergency power systems for a wide range of commercial

More information

Introduction. Emergency Systems Synergy Control Systems. Lithonia Emergency Systems E3 - E16 Lithonia Synergy Control SS1 - SS9.

Introduction. Emergency Systems Synergy Control Systems. Lithonia Emergency Systems E3 - E16 Lithonia Synergy Control SS1 - SS9. Introduction Emergency Systems Synergy Control Systems { Systems Lithonia Emergency Systems E3 - E16 Lithonia Synergy Control SS1 - SS9 EMERGENCY SYSTEMS Emergency lighting is required by building codes

More information

DISTRIBUTOR SELECT COLLECTION. EMERGI-LITE Full range of emergency lighting solutions

DISTRIBUTOR SELECT COLLECTION. EMERGI-LITE Full range of emergency lighting solutions COLLECTION EMERGI-LITE Full range of emergency lighting solutions Distributor Select products Popular emergency lighting products are in stock and ready to ship from warehouses across North America for

More information

NYC Approved Product Series

NYC Approved Product Series NYC Approved Product Series ON THE PROJECT, ON THE SHELF, ON THE JOB NYC APPROVED Table of Contents NYC Approved LED Exit & Combo Series P. 2 NYC Approved LED Battery Series P. 3 NYC Approved Total Edge

More information

IOTA Exit Signs. IOTA Emergency Fixtures

IOTA Exit Signs. IOTA Emergency Fixtures IOTA Exit Signs IOTA Exit Signs offer a variety of models to meet your interior egress requirements. IOTA Exit solutions are designed and manufactured for efficient, long-lasting performance, easy installation,

More information

NEMA-4X Series. Certified for Harsh Environment Applications

NEMA-4X Series. Certified for Harsh Environment Applications NEMA-4X Series Certified for Harsh Environment Applications NEMA-4X Family The industry standard for emergency lighting in harsh environments is here. Battery units, remote fixtures, exit signage and combination

More information

Pictogram Exit Signs Catalogue

Pictogram Exit Signs Catalogue Pictogram Exit Signs Catalogue Introducing new Pictogram Exit Signs To harmonize with existing international standards (ISO 7010 and ISO 3864-1), the National Building Code of Canada (NBC) released at

More information

Lights the way to safety SEVERE SERIES. Certified for Food Preparation and Cold Storage Applications. NEMA-4X Certified for Harsh Environments

Lights the way to safety SEVERE SERIES. Certified for Food Preparation and Cold Storage Applications. NEMA-4X Certified for Harsh Environments Lights the way to safety SEVERE SERIES Certified for Food Preparation and Cold Storage Applications NEMA-4X Certified for Harsh Environments TABLE OF CONTENTS NSF - WHAT & WHAY? SEVERE SERIES FAMILY 2

More information

The New Lux-Ray LED Emergency Lighting

The New Lux-Ray LED Emergency Lighting ON THE PROJECT, ON THE SHELF, ON THE JOB The New Lux-Ray LED Emergency Lighting RUGGED. VERSATILE. SOPHISTICATED MINIATURIZATION The New Lux-Ray LED Emergency Lighting For first-class performance in emergency

More information

Nightfall. led emergency egress lighting

Nightfall. led emergency egress lighting Nightfall led emergency egress lighting Nightfall led emergency egress lighting Combining a sleek, architectural, low profile design with high performance makes the Nightfall Series an attractive LED solution

More information

Outdoor Emergency Lighting Application Guide

Outdoor Emergency Lighting Application Guide Outdoor Emergency Lighting Application Guide www.lithonia.com/outdooremergency Outdoor Emergency Lighting Application Guide Table of Contents: Subject Page Introduction... 1 Power Sources... 2 Normally

More information

PRODUCT OFFERING QUALITY VALUE VERSATILITY

PRODUCT OFFERING QUALITY VALUE VERSATILITY PRODUCT OFFERING QUALITY VALUE VERSATILITY LED FAMILY The Compass LED product series includes economical energy saving fixtures suitable for use in any commercial or light industrial application. Value

More information

Distributor Select LED Families

Distributor Select LED Families Distributor Select LED Families Low energy and low maintenance for moderate budget application ON THE PROJECT, ON THE SHELF, ON THE JOB MICRO LED Family EL-2LED Series ELXN400 LED Series EF43 & EF44D Series

More information

Exit/Emergency Lighting Guide

Exit/Emergency Lighting Guide Exit/Emergency Lighting Guide 1 Exit/Emergency Lighting Guide Table of Contents Exit Signs... 3 Exit/Emergency Combo... 5 Emergency Lights... 7 Accessories... 14 Emergency Ballasts... 17 2 HL0301 Compact

More information

TABLE OF CONTENTS. DLM LED Emergency Light DLH LED Remote Heads DLP Wet Location LED Emergency Light...25

TABLE OF CONTENTS. DLM LED Emergency Light DLH LED Remote Heads DLP Wet Location LED Emergency Light...25 ABOUT SIMKAR Simkar is a nationally known designer, developer, and manufacturer of innovative lighting solutions since 1952. We are committed to providing a diverse selection of high-quality LED lighting

More information

Applications. Standard Materials

Applications. Standard Materials Mercmaster III Low Profile Compact Fluorescent Luminaires Compact Fluorescent listed for simultaneous exposure to combustible dusts and flammable gases or vapors. Applications Enclosed and gasketed fixtures

More information

Catalog Number. Notes. Type. FST Snap on frosted, diffuse L/LENS No diffuser

Catalog Number. Notes. Type. FST Snap on frosted, diffuse L/LENS No diffuser Catalog Number FEATURES & SPECIFICATIONS INTENDED USE Built on the compact, low-profile Z strip channel, this LED strip offers long maintenance-free life, several color s, lumen outputs and lengths. Ideal

More information

Catalog Number. Notes

Catalog Number. Notes Catalog Number FEATURES & SPECIFICATIONS INTENDED USE Built on the compact, low-profile Z strip channel, this LED strip offers long maintenance-free life, several color s, lumen outputs and lengths. Ideal

More information

Power (max) Current (max)

Power (max) Current (max) NEMA-3R Patent-Pending Lux-Ray LED Series Die-Cast aluminum housing, available in four finishes: dark bronze, off-white, black, and platinum gray Nema-3R rated for indoor/outdoor wet, damp & cold locations:

More information

THE UNITED LIGHTING GROUP

THE UNITED LIGHTING GROUP Apartment Lights pp. 02-11 Common Spaces pp. 12-21 Utility & Exits... pp. 22-27 Exterior Lights pp. 28-30 THE UNITED LIGHTING GROUP www.ulgroupusa.com Support@ULGroupUSA.com Apt Hall / Foyer [ceiling surface]

More information

Architectural / led luminaires

Architectural / led luminaires Introducing... An indoor/outdoor architecturally styled high performance LED Luminaire available with normally-on operation powered by line voltage, emergency operation powered by a Nickel-Cadmium battery

More information

Exit Signs, Emergency Lighting & Fluorescent Emergency Ballasts

Exit Signs, Emergency Lighting & Fluorescent Emergency Ballasts Exit Signs, Emergency Lighting & Fluorescent Emergency allasts rochure LEXLED SERIES ILLUMINATION Ultra-bright, long-life, energy effi cient red or green LED s. 1.2V long-life, maintenance-free, rechargeable

More information

Grüv Flare Regressed. Recessed Linear LED

Grüv Flare Regressed. Recessed Linear LED Grüv Flare Regressed Features The Gruv Flare Regressed fixture provides high-performance, visually comfortable, high efficient ambient lighting. Designed with a regressed lens and a flared aperture, the

More information

Project. Comments. Prepared by

Project. Comments. Prepared by DESCRIPTION The Sure-Lites Emergency Light SELM series is a UL924 code compliant solution designed to run for a minimum of 90 minutes during a outage. Key features of the series include: a nickel cadmium

More information

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS. NXM Series - Survive-All. Emergency Light Unit

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS. NXM Series - Survive-All. Emergency Light Unit Emergency Light Unit IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed including the following: READ AND FOLLOW ALL SAFETY INSTRUCTIONS 1. Do not

More information

LED Family Series. Low energy and low maintenance for moderate budget application LIFE SAFETY EQUIPMENT

LED Family Series. Low energy and low maintenance for moderate budget application LIFE SAFETY EQUIPMENT Lights the way to safety LED Family Series Low energy and low maintenance for moderate budget application LIFE SAFETY EQUIPMENT Cluster LED Family LCA-LEDR Series UQLXN500-LED Series ELF65D Series FEATURES

More information

Project. Comments. Prepared by. - EZ Hang feature facilitates fast - Prorated 5-year battery warranty - Overload / Short Circuit - NEC/OSHA

Project. Comments. Prepared by. - EZ Hang feature facilitates fast - Prorated 5-year battery warranty - Overload / Short Circuit - NEC/OSHA DESCRIPTION The Sure-Lites emergency series (SEL) is a UL 924 code compliant LED solution that provides from 25 feet to 60 feet of emergency egress coverage for a minimum of 90 minutes during a power outage.

More information

VIENTO MEDIUM AREA & SITE LED LUMINAIRE OPTICS

VIENTO MEDIUM AREA & SITE LED LUMINAIRE OPTICS PROJECT INFORMATION Project Name Date VIENTO MEDIUM Catalog # APPLICATIONS Auto Dealership Sales Lots Parking Lots Educational/Business Campuses Type Parks & Recreation Areas Security Areas Mall & Retail

More information

EarthTronics products. About us. Where efficiency meets innovation. T5 & T8 Linear. Founded in 2007, EarthTronics, Inc. is a Michigan based

EarthTronics products. About us. Where efficiency meets innovation. T5 & T8 Linear. Founded in 2007, EarthTronics, Inc. is a Michigan based LED Product Guide About us EarthTronics products We are dedicated to developing innovative energy efficient lighting products that provide a positive economic and environmental impact for our customers.

More information

Sure-Lites. 13" [330mm] 3 1/8" [80mm] 4 3/4" [121mm] Emergency Light w/remote Capacity SEL SERIES

Sure-Lites. 13 [330mm] 3 1/8 [80mm] 4 3/4 [121mm] Emergency Light w/remote Capacity SEL SERIES DESCRIPTION The Sure-Lites Emergency Light SEL series is a UL924 code compliant solution designed to run for a minimum of 90 minutes during a outage. Key features of the series include: a nickel cadmium

More information

Catalog Number. Notes. Type

Catalog Number. Notes. Type FEATURES & SPECIFICATIONS INTENDED USE Ideal one-for-one replacement of conventional high bay systems such as HID and fluorescent. Applications include warehousing, manufacturing and other large indoor

More information

life safety products

life safety products SINCE 1923 life safety products 2 Letter from CEO Dear Valued Customer, The Mule Battery Company was founded in 1923 with two thoughts in mind to provide quality products and to back them with exemplary

More information

Grüv Flare Regressed. Recessed Linear LED

Grüv Flare Regressed. Recessed Linear LED Grüv Flare Regressed Features The Gruv Flare Regressed fixture provides high-performance, visually comfortable, high efficient ambient lighting. Designed with a regressed lens and a flared aperture, the

More information

Choice of factory set distributions. Thermally set white polyester powder paint. Optional wet location listing

Choice of factory set distributions. Thermally set white polyester powder paint. Optional wet location listing LOBAY The Lobay luminaire combines the efficiency of HID light sources with special lens optics to create an enclosed luminaire that produces a wide variety of lighting distributions. This makes Lobay

More information

CHINESE NEW YEAR DEADLINE SOLUTIONS

CHINESE NEW YEAR DEADLINE SOLUTIONS LED MADE-TO-ORDER CHINESE NEW YEAR DEADLINE SOLUTIONS Past the mid-october 17 large project deadline for deliveries required before April, 2018? Have an order between November and March and need it faster?

More information

Step Lighting. For indoor and outdoor, stair and pathway applications. Juno Lighting Group Juno Step Lighting 1

Step Lighting. For indoor and outdoor, stair and pathway applications. Juno Lighting Group Juno Step Lighting 1 Step Lighting For indoor and outdoor, stair and pathway applications Juno Lighting Group Juno Step Lighting 1 Lighting your way Table of Contents Mini LED Step Lights p. 4-9 Performance LED Step Lights

More information

RAZOR RZR SERIES DIE CAST ALUMINUM LED EXIT SIGNS INSTALLATION AND OPERATING INSTRUCTIONS IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS

RAZOR RZR SERIES DIE CAST ALUMINUM LED EXIT SIGNS INSTALLATION AND OPERATING INSTRUCTIONS IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS RAZOR RZR SERIES DIE CAST ALUMINUM LED EXIT SIGNS INSTALLATION AND OPERATING INSTRUCTIONS IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed including

More information

CATALOG NUMBER NAME DESCRIPTION HTL X Keeper 2 40 Watts 120v 5000K 4,000 Lm HTL X Keeper 2 40 Watts 277v 5000K 4,000 Lm 4.

CATALOG NUMBER NAME DESCRIPTION HTL X Keeper 2 40 Watts 120v 5000K 4,000 Lm HTL X Keeper 2 40 Watts 277v 5000K 4,000 Lm 4. SPECIFICATIONS hazloclinear LIGHTING 120 & 277 Voltage KEY FEATURES Two Models: 120 vac or 277 vac. Die Cast aluminum fixture for LED heat dissipation and thermal control. 40 watts, 4000 lumens, Epistar

More information

SDL4 LED Strip Diffused Lens

SDL4 LED Strip Diffused Lens Catalog # : Project : Prepared By : Date : SDL4 The sleek architectural SDL is designed with tooless entry features saving time and money on installation. Optimizing industry leading LED technology, the

More information

BAS SDL8' LED Strip Diffused Lens

BAS SDL8' LED Strip Diffused Lens Project Name Fixture Type Catalog # BAS SDL8' The sleek architectural SDL is designed with tooless entry features saving time and money on installation. Optimizing industry leading LED technology, the

More information

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 26 ELECTRICAL

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 26 ELECTRICAL SECTION 265100 - INTERIOR LIGHTING PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following: 1. Interior lighting fixtures, lamps, and ballasts. 2. Emergency lighting units. 3. Exit signs. 4.

More information

SECTION INTERIOR AND EXTERIOR LIGHTING FIXTURES

SECTION INTERIOR AND EXTERIOR LIGHTING FIXTURES SECTION 26 50 00 INTERIOR AND EXTERIOR LIGHTING FIXTURES PART 1: GENERAL 1.1 WORK INCLUDED: A. Interior lighting fixtures and accessories B. Exterior lighting fixtures and accessories C. Emergency battery

More information

SETION EMERGENCY LIGHTING NATIONAL FIRE PROTECTION ASSOCIATION (NEPA) (2006) Life Safety Code, 2006 Edition

SETION EMERGENCY LIGHTING NATIONAL FIRE PROTECTION ASSOCIATION (NEPA) (2006) Life Safety Code, 2006 Edition SETION 16420 PART 1 - GENERAL 1.01 REFERENCES The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation

More information

Maxim3 TM Series IP66. LED Vapor Tight - Waterproof Key Features

Maxim3 TM Series IP66. LED Vapor Tight - Waterproof Key Features Maxim3 TM Series PROJECT NAME: CATALOG: NOTES: LED Vapor Tight - Waterproof Key Features Up to 146 IP66 87 UL 4, 5 & 8 K & K 110-277V NSF Stainless Steel Clips Operating Temp - o F to 105 o F 7 Year Warranty

More information

THE COMPLETE GUIDE TO OUTDOOR WALL LIGHTS

THE COMPLETE GUIDE TO OUTDOOR WALL LIGHTS THE COMPLETE GUIDE TO OUTDOOR WALL LIGHTS CONTENTS 1. INTRODUCTION 2. TYPES OF OUTDOOR WALL LIGHTS 3. LIGHT SOURCES IN OUTDOOR WALL LIGHTS 4. FACTORS IN SELECTING OUTDOOR WALL LIGHTS 5. SUMMARY lighting

More information

CALIBER LIGHTING. SERIES 4VDWWL Shower Lens LED Dim-to-Warm Recessed Downlight, 1018 Lumen APPLICATION PRODUCT DATA. 4VLEDWL Example: 4VLEDWLSCLPF

CALIBER LIGHTING. SERIES 4VDWWL Shower Lens LED Dim-to-Warm Recessed Downlight, 1018 Lumen APPLICATION PRODUCT DATA. 4VLEDWL Example: 4VLEDWLSCLPF APPLICATION Small aperture medium distribution downlight is suitable for applications that require a dim-to-warm long life LED lamp source and a lensed wet location reflector. PRODUCT DATA LED MODULE:

More information

3.75 Gyro Shift Multiples Single Head

3.75 Gyro Shift Multiples Single Head CATALOG#: PROJECT: FIXTURE TYPE: CONTACT: PHONE: Wattage CCT Delivered Lumens Efficacy 10W 3000K 966lm 97lpw 15W 3000K 1437lm 96lpw 20W 3000K 1739lm 87lpw 25W 3000K 2049lm 82lpw 30W 3000K 2254lm 75lpw

More information

Hazardous Location LED String Lights - 5 Jelly Jar Lamps - Non Metallic - Chemical Resistant - CID2

Hazardous Location LED String Lights - 5 Jelly Jar Lamps - Non Metallic - Chemical Resistant - CID2 Hazardous Location LED String Lights - 5 Jelly Jar Lamps - Non Metallic - Chemical Resistant - CID2 Part #: HAL-SL-5-LED Page: 1 Made in Texas The Larson Electronics HAL-SL-5-LED Explosion Proof LED String

More information

Suite: Foyer/Hallway/Closet PROJECT: ZIGG CONDOS TYPES ' S1 ' & ' S6 ' Description: Flush Mount lass. Finish: Diameter: " Height: 4" Lamp: x

Suite: Foyer/Hallway/Closet PROJECT: ZIGG CONDOS TYPES ' S1 ' & ' S6 ' Description: Flush Mount lass. Finish: Diameter:  Height: 4 Lamp: x Suite: Foyer/Hallway/Closet PROJECT: ZIGG CONDOS TYPES ' S1 ' & ' S6 ' Description: Flush Mount lass Finish: Diameter: " Height: 4" Lamp: x 352-(&7 =,** &21'26 7

More information

4 LED Recessed Adjustable. Energy efficient, stylish downlighting for residential and commercial applications

4 LED Recessed Adjustable. Energy efficient, stylish downlighting for residential and commercial applications 4 LED Recessed Adjustable Energy efficient, stylish downlighting for residential and commercial applications The most efficient, stylish, high-performance downlight is now adjustable Juno Generation 4

More information

Dimensions (111mm) (111mm) 3 (76mm)

Dimensions (111mm) (111mm) 3 (76mm) Catalog # : Project : Prepared By : Date : S8 The sleek architectural S is designed with tooless entry features saving time and money on installation. Optimizing industry leading LED technology, the series

More information

IVR15-RPS O.D. Solid State Illuminated Rail Remote Power Supply

IVR15-RPS O.D. Solid State Illuminated Rail Remote Power Supply IVR15RPS O.D. Solid State Illuminated Rail Remote Power Supply 1.50 recognized 0.3 90 APERTURE Ends of Illuminated rail field cutable to a minimum of 2 1/8 in length. Illuminated rail is available with

More information

LED FIXTURE CATALOG. Shining light into the future

LED FIXTURE CATALOG. Shining light into the future LED FIXTURE CATALOG Shining light into the future Company Profile Ohyama Lights, LLC strives to be an innovative company that is responsive to its customers needs. Our mission is to put the customer first

More information

Pathway Lighting. Introduction

Pathway Lighting. Introduction The Encore Landscape Lighting System combined with Encore s superior products will create beauty, safety, and security all in a simpleto-install system. The Encore Landscape Lighting System allows for

More information

Product Specifications MaxLumen MRI LED Diffused Lighting

Product Specifications MaxLumen MRI LED Diffused Lighting NOVA Energy & Automation Product Specifications MaxLumen MRI LED Diffused Lighting Model MXLumen22-X 03 January 2012 Product Description 1. Standard Applications The Nova Max Lumen LED 2x2 light fixture

More information

light ACL9 ANATOMY PERIMETER FOCUSED INSTALLATION SLEEK & STRONG

light ACL9 ANATOMY PERIMETER FOCUSED INSTALLATION SLEEK & STRONG ACL9 ACL9 ANATOMY SLEEK & STRONG A stylish rectilinear aluminum extrusion made of 60% recycled material provides ultimate durability and functionality. 3.325 2.25 0.63 PERIMETER FOCUSED INSTALLATION A

More information

A complete range of Specification Grade Emergency Lighting Products and Accessories ON THE PROJECT, ON THE SHELF, ON THE JOB

A complete range of Specification Grade Emergency Lighting Products and Accessories ON THE PROJECT, ON THE SHELF, ON THE JOB A complete range of Specification Grade Emergency Lighting Products and Accessories ON THE PROJECT, ON THE SHELF, ON THE JOB TABLE OF CONTENTS INTRODUCTION Company Profile... 2-3 MR16 LED.... 4-5 Nexus

More information

Max 4 Flush Lens RECESSED

Max 4 Flush Lens RECESSED Overview Flush 4 inch LED linear snap-in lens Sleek, slender contemporary design Easy to install T-Grid, S-Slot Grid, Tech Zone Ready Special - no light leak ends feature Ordering Format PART NUMBER: MX4-F

More information

Bdl60u Fluorescent Emergency Ballast

Bdl60u Fluorescent Emergency Ballast A Division Of Philips Electronics North America Corporation One- or two-lamp emergency; Universal input voltage: 120 through 277 V, 50 or 60 Hz; Replaces B60U Bdl60u Fluorescent Emergency Ballast Product

More information

Stocking Solutions. Downlights LED Panels Floods & Wall Packs

Stocking Solutions. Downlights LED Panels Floods & Wall Packs Stocking Solutions Downlights LED Panels Floods & Wall Packs Because Experience Makes the Difference Since 1976, LSI Industries has been introducing smart, innovative lighting solutions to help its customers

More information

150W Explosion Proof High Bay LED Light Fixture - C1D1&2 - C2D1&2-17,500 Lumens - 60 Beam

150W Explosion Proof High Bay LED Light Fixture - C1D1&2 - C2D1&2-17,500 Lumens - 60 Beam 150W Explosion Proof High Bay LED Light Fixture - C1D1&2 - C2D1&2-17,500 Lumens - 60 Beam Part #: EPLC2-HB-155W-LED-PND Page: 1 The Larson Electronics EPLC2-HB-155W-LED-PND Explosion Proof High Bay light

More information

Dimensions (111mm) 3 (76mm) (111mm) (48mm)

Dimensions (111mm) 3 (76mm) (111mm) (48mm) Catalog # : Project : Prepared By : Date : S2 The sleek architectural S is designed with tooless entry features saving time and money on installation. Optimizing Industry LED technology, the S series delivers

More information

ELECTRONIC SOUNDER STROBE Model : AVD-C407

ELECTRONIC SOUNDER STROBE Model : AVD-C407 ELECTRONIC SOUNDER STROBE Model : AVD-C407 MULTRON range of combination Electronic Sounders with Strobe Lights are designed to complement our Fire Alarm products both technically and aesthetically as an

More information

LED RETROFIT CONVERSION KITS

LED RETROFIT CONVERSION KITS Our LED RetroFit Conversion Kits come with a complete Gear Tray Assembly to convert older 4-foot and 8-foot T8 or T12 strip-type fixtures into energy efficient LED luminaires. High quality components and

More information

CHECK NEW PRODUCTS SECTION FOR NEW INNOVATIVE SOLUTIONS

CHECK NEW PRODUCTS SECTION FOR NEW INNOVATIVE SOLUTIONS CHECK NEW PRODUCTS SECTION FOR NEW INNOVATIVE SOLUTIONS Table of Contents - Electronic Access & Releasing Devices Pushbutton Access Release Devices................ H1-H8 620/631 Series Heavy Duty Pushbuttons

More information

Class 1 Div 2 LED Pivoting Light - 2 foot 2 lamp - LED T series Style V Dimmable

Class 1 Div 2 LED Pivoting Light - 2 foot 2 lamp - LED T series Style V Dimmable Class 1 Div 2 LED Pivoting Light - 2 foot 2 lamp - LED T series Style - 0-10V Dimmable Part #: HAL-24-2L-LED-BMSW-D-V2 Page: 1 Made in the USA The Larson Electronics HAL-24-2L-LED-BMSW-D-V2 Hazardous Area

More information

Industrial 100 Watt Ultraviolet LED Light Fixture - Paint Spray Booth Approved Nanometer

Industrial 100 Watt Ultraviolet LED Light Fixture - Paint Spray Booth Approved Nanometer Industrial 100 Watt Ultraviolet LED Light Fixture - Paint Spray Booth Approved - 365 Nanometer Part #: GAU-HB-100LED-RT-UVA The Larson Electronics GAU-HB-100LED-RT-UVA Industrial Ultraviolet light fixture

More information

LUCE 1 TL. specifications: internal. specifications: external. ordering logic. builder. Job/Location:

LUCE 1 TL. specifications: internal. specifications: external. ordering logic. builder. Job/Location: LUCE 1 TL indoor / damp Job/Location: Contractor: Prepared By: Job Type: Date: The LUCE-1TL thinline emergency ballast is designed to provide emergency illumination to existing or new fluorescent luminaires.

More information

New LED Product Offerings

New LED Product Offerings New LED Product Offerings from we know light. TCP LED NEW Product Offerings LED Indoor Lighting PL Lamps EdgeLit Downlights HID DirecT8/DirecT5 T8/T5 Tubes Liscio by TCP Linear Accent Lighting Luxterior

More information

Hornet HP. Square Glass Downlight

Hornet HP. Square Glass Downlight Features The Hornet 3.5" helps define architectural spaces with a decorative, satin opal, etched glass cylinder that breaks the ceiling plane, providing a warm glow ideal for ambient and task lighting.

More information

SECTION INTERIOR LIGHTING

SECTION INTERIOR LIGHTING SECTION 26 51 00 INTERIOR LIGHTING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

The Beghelli Group. Founded in 1982 by Gian Pietro Beghelli, the Beghelli Group is an Italian and European emergency lighting.

The Beghelli Group. Founded in 1982 by Gian Pietro Beghelli, the Beghelli Group is an Italian and European emergency lighting. The Beg The Beghelli Group Il Gruppo Beghelli Introduction Founded in 1982 by Gian Pietro Beghelli, the Beghelli Group is an Italian and European emergency lighting leader that also operates in the fields

More information

Enhancing the Lighting Experience

Enhancing the Lighting Experience Enhancing the Lighting Experience 2017/2018 CATALOG COMMERCIAL INDUSTRIAL RESIDENTIAL ETi Solid State Lighting means value, quality, and performance. Our parent company, Elec-Tech Solid State Lighting

More information

Hornet HP. Round Glass Downlight

Hornet HP. Round Glass Downlight Round Glass Downlight Features The Hornet 3.5" Round Glass Downlight helps define architectural spaces with a decorative, satin opal, etched glass cylinder that breaks the ceiling plane, providing a warm

More information

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS. 3LERHZ Series Class I, Div 2 Combo Unit. Installation instructions

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS. 3LERHZ Series Class I, Div 2 Combo Unit. Installation instructions 3LERHZ Series Class I, Div 2 Combo Unit Installation instructions 3LERHZ Series Class I, Div 2 Combo Unit IMPORTANT SAFEGUARDS 1 3 When using electrical equipment, basic safety precautions should always

More information

Truss Surface SURFACE

Truss Surface SURFACE Overview Realistic steel truss in aluminum One piece extruded aluminum housing with integral driver Direct light only Continuous row mounting; standard Can also be specified as pendant or surface wall

More information

LMV Series W Low Profile - Medium Base

LMV Series W Low Profile - Medium Base L LMV Series 50-150W Low Profile - Medium Base Cl. I, Div. 2, Groups A, B, C, D Restricted Breathing Cl. I, Div. 2 & Zone 2 (Suffix S826) Certified for IEC Zone 2 (Suffix S826TB) Cl. II, Groups E, F, G;

More information

C2D1/C1D2 Explosion Proof 50 Watt LED Light Fixture - Paint Spray Booth Approved - 6,250 Lumens

C2D1/C1D2 Explosion Proof 50 Watt LED Light Fixture - Paint Spray Booth Approved - 6,250 Lumens C2D1/C1D2 Explosion Proof 50 Watt LED Light Fixture - Paint Spray Booth Approved - 6,250 Lumens Part #: EPLC2-HB-50LED-RT Page: 1 The Larson Electronics EPLC2-HB-50LED-RT Explosion Proof High Bay light

More information

A. Furnish and install luminaires, lamps, ballasts and in-line fuses as herein specified and shown on the Drawings.

A. Furnish and install luminaires, lamps, ballasts and in-line fuses as herein specified and shown on the Drawings. DIVISION 26 ELECTRICAL SECTION 26 51 13 PART 1 GENERAL 1.01 DESCRIPTION A. Furnish and install luminaires, lamps, ballasts and in-line fuses as herein specified and shown on the Drawings. B. Luminaire

More information

Essentials Series 4.0

Essentials Series 4.0 Essentials Series 4.0 LED High Bay Essentials Series 4.0 provides the highest quality, reliability and performance with extraordinary lumen maintenance and efficacy, delivering superior ROI for your application.

More information

BeveLED Cylinder LBRP6 Surface

BeveLED Cylinder LBRP6 Surface LBRP6 CYLINDER SURFACE CYLINDER SURFACE WITH CROSS BAFFLE /cylinders Shown with cross baffle Power and beauty are both in play with our sleek architectural cylinders. The provides industry-leading performance

More information

Hazardous Location LED Pivoting Light - C1D2 - Dimmable - Modbus TCP/IP Network - Meets USCG Specs

Hazardous Location LED Pivoting Light - C1D2 - Dimmable - Modbus TCP/IP Network - Meets USCG Specs Hazardous Location LED Pivoting Light - C1D2 - Dimmable - Modbus TCP/IP Network - Meets USCG Specs Part #: HALP-ANC-48-2L-LED-D-V2 Page: 1 Made in the USA The Larson Electronics HALP-ANC-48-2L-LED-D-V2

More information

SOLID STATE ILLUMINATED RAIL

SOLID STATE ILLUMINATED RAIL SOLID STATE ILLUMINATED RAIL Grand Park, Los Angeles California Lighting Design: The Lighting Design Alliance Installation: Rosendin Electric Manufacturer Representative: Performance Lighting Systems

More information

Explosion Proof UV/Visible Light Fluorescent Fixture - Paint Spray Booth, Rigs - Two Circuit Lamps

Explosion Proof UV/Visible Light Fluorescent Fixture - Paint Spray Booth, Rigs - Two Circuit Lamps Explosion Proof UV/Visible Light Fluorescent Fixture - Paint Spray Booth, Rigs - Two Circuit Lamps Part #: EPL-48-2L-T8-VISUVA Page: 1 The Larson Electronics EPL-48-2L-T8-VISUVA Explosion Proof UV/Visible

More information

PROJECT DATE FLANGE FINISH

PROJECT DATE FLANGE FINISH PROJECT INFORMATION PROJECT DATE TYPE 1" 2-1/2" BeveLED Recessed Downlight - Illuminate your space with any color available in the spectrum with BeveLED Infinite Color+. Tune the light from saturated blue,

More information

DC-1000 DECAL WORLD KIT. Part # Description Qty Part # Description Qty DECAL KIT

DC-1000 DECAL WORLD KIT. Part # Description Qty Part # Description Qty DECAL KIT DC-00............... American Flag () DC-00.................. No Riders () DC-00............ Finger pinch point () DC-00......... Warning serious injury () DC-005.............. Fasten seat belt () DC-006.....

More information

BALLAST SOURCE EB- Electronic ballast BALLAST QUANTITY. 1-(1) 4-light ballast LAMP SPECIFICATIONS SPECIFICATIONS

BALLAST SOURCE EB- Electronic ballast BALLAST QUANTITY. 1-(1) 4-light ballast LAMP SPECIFICATIONS SPECIFICATIONS CATALOG NO. TYPE NO. JOB NAME SmarT-Bay 4-Light T8 ORDERING INFORMATION Catalog Number: Example: SBN432EB1-4JP SB N 4 32 EB 1 FIXTURE SB- SmarT- Bay Series Industrials BODY WIDTH N- Narrow (4 Light) LAMPS

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-26 52 00.00 40 (November 2017) ----------------------------------- Preparing Activity: NASA Superseding UFGS-26 52 00.00 40 (August 2014) UNIFIED FACILITIES GUIDE SPECIFICATIONS

More information

Lithonia Lighting LED Downlighting. A Solutions Guide For Every Need, Every Application, Every Budget

Lithonia Lighting LED Downlighting. A Solutions Guide For Every Need, Every Application, Every Budget Lithonia Lighting LED Downlighting A Solutions Guide For Every Need, Every Application, Every Budget 2012 A Comprehensive and Balanced Portfolio of LED Downlighting Solutions Lithonia Lighting balances

More information

MAR2 LED SERIES M A R 2 L E D. Linear LED Lighting for Hazardous Locations

MAR2 LED SERIES M A R 2 L E D. Linear LED Lighting for Hazardous Locations MAR2 LED SERIES Linear LED Lighting for Hazardous Locations Class I, Division 2, Groups A, B, C & D UL 844 Hazardous Locations UL 1598A Marine Outside Type UL 8750 LED Safety CSA C22.2 #250.0-08; CSA C22.2

More information

SERVICE REPORT REPORT SUMMARY OPTIONAL ITEMS. 1 P a g e TECHNICIAN: BOB WILDER SERVICE ADDRESS: 3047 N LINCOLN AVE SERVICE DATE: 12/2/2015

SERVICE REPORT REPORT SUMMARY OPTIONAL ITEMS. 1 P a g e TECHNICIAN: BOB WILDER SERVICE ADDRESS: 3047 N LINCOLN AVE SERVICE DATE: 12/2/2015 SERVICE REPORT TECHNICIAN: BOB WILDER SERVICE ADDRESS: 3047 N LINCOLN AVE SERVICE DATE: 12/2/2015 REPORT SUMMARY This report documents the recent on-site servicing of the building s fire safety equipment.

More information

Who is Iconic LED? Page 2. Phone:(337)

Who is Iconic LED? Page 2. Phone:(337) Who is Iconic LED? At Iconic LED our mission is to be an icon in the lighting industry by providing excellent customer service, and quality products through a traditional distribution model focused on

More information

Capella 2. Project Name. Construction. Optical System. Product Applications. Housing and lens frame are constructed from heavy-duty low

Capella 2. Project Name. Construction. Optical System. Product Applications. Housing and lens frame are constructed from heavy-duty low Product # Type Date Project Name Project Location Prepared By Capella 2 Construction Y Housing and lens frame are constructed from heavy-duty low Glass Lens is Minimum 1/8 thick thermal and impact resistant

More information

LHBXD LED Linear High Bay

LHBXD LED Linear High Bay Catalog # : Project : Prepared By : Date : LHBXD The LHBXD is the perfect solution for a wide variety of applications and mounting heights. It s competitive pricing, multiple lumen packages, and high ambient

More information

Evolution EXWW RECESSED LINEAR WALL WASH LUMINAIRE

Evolution EXWW RECESSED LINEAR WALL WASH LUMINAIRE Evolution EXWW Project Name Date Type RECESSED LINEAR WALL WASH LUMINAIRE 3-13/16 (96.8mm) 5-1/8 (130.2mm) Extruded aluminum trim with formed cold rolled 20 gauge steel back box housing Highly reflective,

More information

Moon Visions Lighting

Moon Visions Lighting Moon Visions Lighting 2018-2019 Product Guide Quality lighting since 2008 214.393.7407 www.moonvisionslighting.com New Light Bar Series! UL Listed under UL Standard 1598 Certified to CSA Standard 1668

More information

Evolve LED Garage Light

Evolve LED Garage Light GE Lighting Evolve LED Garage Light (EG2R) imagination at work Product Features High quality lighting meets long life and controllability with the Evolve LED Garage Light, EG2R. This fixture features an

More information

Modular & linear architectural lighting for residential and commercial environments.

Modular & linear architectural lighting for residential and commercial environments. THIN Lighting System Modular & linear architectural lighting for residential and commercial environments. 2 THIN System Product Guide AP P L I CATI O NS : S U S PE N S IO N Office Lighting Suspended Task

More information

3 2 1 A B D F

3 2 1 A B D F 3 2 1 A B D F A 3 2 1 A B D F 3 2 1 A B D F Mechanical, Electrical & Energy Consultants 7600 East Orchard Road, Suite 250-S Greenwood Village, CO 80111-2518 tel: 303.796.6000 Fax: 303.796.6099

More information

5 yr. Vitalite Rotating Warning Light. Models 121 and 121A LIGHT DUTY VEHICULAR LIGHT

5 yr. Vitalite Rotating Warning Light. Models 121 and 121A LIGHT DUTY VEHICULAR LIGHT FEDERAL SIGNAL CORPORATION Vitalite Rotating Warning Light Models 121 and 121A LIGHT DUTY VEHICULAR LIGHT Available in 12VDC and 24VDC Five dome colors 121 - Magnetic mount with cigarette lighter cord

More information