Distribution Control Center Operator Training
|
|
- Harriet Sanders
- 5 years ago
- Views:
Transcription
1 Distribution Control Center Operator Training OnlineTraining 15-Hour Course COURSE I BASIC DISTRIBUTION 1. Introduction to Distribution Systems a. Terminology b. Basic electricity and Ohm s Law c. BES distribution overview 2. Distribution Design and Resource Planning a. Regulatory requirements (NEC, NESC, etc.) b. Electrical drawings c. Feeder drawings d. Distribution planning e. Integrated resource planning 3. Distribution Equipment a. Substation: transformers, regulators, breakers, reclosers, air switches, capacitors, and reactors b. Distribution feeders: radial, loop, wye, delta, one-phase, and three-phase services c. Overhead primary: poles, grounding methods, conductors, and insulators d. Underground primary: transition structures, cables, elbows, and splices e. Padmount transformers, reclosers, and switches 4. Distribution Protection a. Faults b. Instrument transformers (PTs, CTs, and CCVTs) c. Protection equipment: DC control circuits, solid and electromechanical relays d. Electronic and hydraulic reclosers e. Coordination: fuses, breakers, reclosers, and sectionalizers About SOS Intl: Headquartered in Charlotte, N.C., SOS Intl is a leading provider of training and advisory services to the power industry. Founded by CEO Rocky Sease, SOS rigorously tracks and interprets NERC Reliability Standards and expertly translates them into customized education and advisory services, helping to manage risk and ensure reliability for the North American power grid. SOS offers NERC system operator certification, classroom and online courses, accompanied by sophisticated computer simulation. Since 2002, SOS has provided NERC-approved continuing education and advisory services to thousands of employees of the Bulk Electric System across the United States and Canada. All training is designed using the latest systematic approach to training, as required by NERC Sikes Place, Charlotte NC Melanie Payne : : sosintl.com Lori Burk : : sosintl.com Kathy Cross : : sosintl.com SOS Intl. and NERC ID SOS_INTL_001 is recognized by the North American Electric Reliability Corporation as a continuing education provider who adheres to NERC Continuing Education Program Criteria.
2 5. Overvoltage Protection a. Lightning characteristics, arresters, and coordination b. Basic Insulation Levels (BIL) c. Protection margins d. Arrester selection 6. SCADA and EMS a. SCADA and RTUs b. Sensors and transducers c. Scale factors d. Energy Management Systems (EMS) e. Distribution control centers f. Utility telecommunications 7. Service Entrance Equipment a. Residential service entrance equipment b. Household wiring c. Industrial three-phase service equipment d. Secondary and primary metering 8. Normal Operations Distribution a. Normal operating conditions b. Voltage control c. Optimal capacitor placement d. Situational awareness 9. Emergency Operations Distribution a. Storm damage and other major natural disturbances b. Managing abnormal conditions c. Emergency load transfers d. Restoration procedures e. Prevention techniques COURSE II ADVANCED DISTRIBUTION CONCEPTS 10. Distribution Reliability a. Service reliability indices (SAIDI, SAIFI, etc.) b. Methods to improve service reliability c. System reliability through telecommunications technologies Secondary and spot networks
3 11. Power Quality a. Power quality issues b. Reduced motor starting overview c. Transformer bank connections and issues d. Transformer bank polarity and troubleshooting e. Stray voltages and currents f. Ferroresonance g. Radio/television interference h. Standby generation and uninterruptible power supplies 12. Planned Maintenance and Test Equipment a. Facility inspections b. Infrared c. Dissolved gas analysis d. Test equipment 13. Smart Grid Systems a. Distributed generation b. Energy storage c. Microgrids d. Smart distribution substations e. Smart devices f. Distribution automation g. Distribution management systems h. Advanced metering infrastructure i. Customer services and information management systems j. Smart homes/buildings and demand side management k. Security and access control l. Demand side load management m. Special communications systems for smart grids n. Trending technologies COURSE III ELECTRICAL SAFETY 14. Regulatory and Grounding Design Concepts a. Overview of applicable codes (NEC, NESC, OSHA) b. Substation and facility grounding c. Power faults d. Fault current distribution
4 15. Effects of Accidental Energization a. Accidental energization b. Ground potential rise c. Zone of Influences d. Touch and step potentials e. Human vulnerability 16. Personal Protection a. Conduction vs isolation b. Personal protection equipment c. Hot sticks d. Equipotential grounding of overhead facilities 17. Underground Safety a. Concerns for underground safety b. Ground potential rise of underground equipment c. Touch and step potentials of underground equipment d. Equipotential grounding of underground facilities 18. Testing Personal Protection Equipment a. Isolation protection equipment b. Conduction protection equipment 19. Arc Flash Analysis and Safety Equipment a. Regulator requirements b. Arc flash protective equipment 20. Switching Practices a. Terminology b. Switching and coordination COURSE IV FUNDAMENTALS OF SYSTEM PROTECTION 21. General Relay Operations a. Primary purpose of protective relays b. Elements for correct relay performance c. Relay types and unique attributes 22. Relay Categories and Input a. Major relay categories b. Power system components providing input to relays c. Relay operations
5 23. Auxiliary Relays a. Red flag and indications meanings b. Different types of auxiliary relays c. Sync check relay 24. Fault Analysis a. Graphical representations of voltage, current, power vectors, and phasors b. Rotational symmetrical components: positive, negative, and zero sequence c. Unique attributes of wye and delta configurations d. Neutral fault current properties 25. Relay Coordination and Back-up Protection a. Relay coordination communication mediums b. Procedures for various relay coordination methods c. Redundant and back-up relaying differences 26. Remedial Action Schemes a. Local-based protection systems b. RAS triggers and actions c. RAS limitations d. Synchrophasors e. RAS installation concerns for system operators 27. Breaker Operations a. Arc quenching mechanisms b. Circuit breaker classifications c. Contact positions in circuit breakers d. Breaker operation power supplies e. Close and trip sequences on breaker control schematics f. Anti-pump feature g. Breaker failure h. Circuit breaker protection schemes i. Operating breakers during abnormal conditions
Microgrid Fault Protection Based on Symmetrical and Differential Current Components
Microgrid Fault Protection Based on Symmetrical and Differential Current Components Prepared for Public Interest Energy Research California Energy Commission Prepared by Hassan Nikkhajoei and Robert H.
More informationNATIONAL ELECTRICAL CODE (NEC) & NFPA 70E ARC FLASH ELECTRICAL SAFETY
A new twist on the National Electrical Code - a practical application workshop. If you sign up in this class, prepare to work! Day 1: Fundamentals of OSHA requirements for performing electrical work -
More informationElectrical Energy department
Al-Balqa Applied University Power systems Protection course Dr Audih al-faoury Electrical Energy department 2018-2019 Department of Electrical Energy Engineering 1 Part 1 Power System protection Introduction
More informationBrown University Revised June 29, 2012 Facilities Design & Construction Standards SECTION ELECTRICAL DESIGN CRITERIA
PART 1 - GENERAL 1.1 Background SECTION 26 00 10- ELECTRICAL DESIGN CRITERIA A. Brown University maintains it own campus electrical distribution system which serves the majority of the buildings and facilities
More informationTRANSMISSION ENGINEERING STANDARDS SUBSTATIONS
This standard was reviewed and approved by key managers on September 6, 2011. Officer approval of this revision is not required. 1.0 SCOPE 1.1 This guide applies to the interconnection of a Utility with
More informationSafety requirements for voltage testing instruments
MODEL POLICY Safety requirements for voltage testing instruments 1. FOREWORD 1.1. Approval 1.1.1. This standard is owned by. name of promulgating organization or department 1.1.2. Questions related to
More informationTRANSMISSION ENGINEERING STANDARDS SUBSTATIONS
This standard was reviewed and approved by key managers with final approval by an officer of Oncor Electric Delivery on. 1.0 SCOPE 1.1 This guide applies to the interconnection of a Customer with the Company
More informationSEL Arc-Flash Solutions
SEL Arc-Flash Solutions Arc-Flash Protection at the Speed of Light Protect personnel and equipment Detect arc-flash events and send a trip signal in as little as 2 ms to enhance safety and minimize equipment
More informationSEL Arc-Flash Solutions
SEL Arc-Flash Solutions Arc-Flash Protection at the Speed of Light Protect personnel and equipment. Detect arc-flash events and send a trip signal in as little as 2 ms to enhance safety and minimize equipment
More informationContents. Preface. Chapter 2 Faults, types and effects The development of simple distribution systems Faults-types and their effects 7
Practical Power System Protection for Engineers and Technicians Contents Preface ix Chapter 1 Need for protection 1 1.1 Need for protective apparatus 1 1.2 Basic requirements of protection 2 1.3 Basic
More informationNational Grid / DG Installation Process Guide per NY SIR / July 2011 ver. 1.0
Distributed Generation Installation Process Guide for Connections to National Grid Distribution Facilities per the New York Standardized Interconnection Requirements Introduction National Grid ( The Company
More informationSDG&E Feeder Protection Philosophy:
SDG&E Feeder Protection Philosophy: Reliability Without Compromising Safety Karl Iliev System Protection and Control Engineering (SPACE) SDG&E 1 SDG&E Distribution System 22,000 miles of lines 60% underground
More informationSTATEWIDE CAREER/TECHNICAL EDUCATION COURSE ARTICULATION REVIEW MINUTES
STATEWIDE CAREER/TECHNICAL EDUCATION COURSE ARTICULATION REVIEW MINUTES Articulation Agreement Identifier: ELT 118 (2005-1) Identifier is the postsecondary course prefix followed by Plan-of-Instruction
More informationTABLE OF CONTENTS CHAPTER 5 SPECIAL OCCUPANCIES CHAPTER 1 GENERAL RULES... 19
TABLE OF CONTENTS About This Textbook...xiii How to Use the National Electrical Code... 1 Article 90 Introduction to the National Electrical Code... 7 90.1 Purpose of the NEC... 7 90.2 Scope of the NEC...
More informationELECTRICAL TESTING TECHNICIAN CERTIFICATION PROGRAM STUDY GUIDE Setting the Standard Energizing the Future
ELECTRICAL TESTING TECHNICIAN CERTIFICATION PROGRAM STUDY GUIDE 2016 Setting the Standard Energizing the Future ELECTRICAL TESTING TECHNICIAN CERTIFICATION PROGRAM STUDY GUIDE Table of Contents About the
More informationTechnical Manual
` HARTEK Control Relay Panel upto 220 KV Technical Manual 2014-15 2 P a g e Contents 1. Why HARTEK Control & Relay Panels? 2. Design Parameters 3. Types of Relays & their functions 4. List of Routine Tests
More informationMAINTENANCE OF LV SWITCHGEAR SECTOR / ENGINEERING TECHNICAL & CERTIFIED TRAINING COURSE
SECTOR / ENGINEERING TECHNICAL & CERTIFIED TRAINING COURSE Switchgear is a general term used for any devices that breaks and makes the electrical circuit and covers right from a typical piano switch used
More informationStandard PRC Protection System, Automatic Reclosing, and Sudden Pressure Relaying Maintenance
A. Introduction 1. Title: Protection System, Automatic Reclosing, and Sudden Pressure Relaying Maintenance 2. Number: PRC-005-6 3. Purpose: To document and implement programs for the maintenance of all
More informationSPECIFICATIONS FOR ELECTRICAL INSTALLATIONS
Attachment PUC 4-8-5 Page 1 of 26 SUPPLEMENT TO SPECIFICATIONS FOR ELECTRICAL INSTALLATIONS PRIMARY METER POLE ELECTRIC SYSTEM BULLETIN No. 753 JUNE 1993, 2ND PRINTING APRIL 2002 (Supersedes issue dated
More informationNATIONAL TRAINING BOARD (ELECTRICIAN) REGULATIONS 2008 BR 54/2008 NATIONAL OCCUPATIONAL CERTIFICATION ACT :38
BR 54/ NATIONAL OCCUPATIONAL CERTIFICATION ACT 2004 2004 :38 The National Training Board, with the approval of the Minister responsible for the National Training Board, in exercise of the powers conferred
More informationChapter 1 General...9 Article 100 Definitions...11 Article 100 Questions Article 110 Requirements for Electrical Installations...
Article 90 Introduction...1 90.1 Purpose of the NEC...1 90.2 Scope of the NEC...2 90.3 Code Arrangement...4 90.4 Enforcement...5 90.5 Mandatory Requirements and Explanatory Material...6 90.6 Formal Interpretations...6
More informationFault Indicators for the Safe, Reliable, and Economical Operation of Modern Power Systems
Fault Indicators for the Safe, Reliable, and Economical Operation of Modern Power Systems 2010 Schweitzer Engineering Laboratories, Inc. All rights reserved Table of Contents Fault Indicators for the Safe,
More informationFACILITY CONNECTION STANDARD
FACILITY CONNECTION STANDARD Preface: This Facility Connection Standard applies to any connection to the electric system of Westar Energy, Inc. or Kansas Gas and Electric Company, both doing business as
More informationSECTION AUTOMATIC TRANSFER SWITCHES
PART 1 - GENERAL 1.1 DESCRIPTION SECTION 26 36 23 This section specifies the furnishing, complete installation, and connection of automatic transfer switches. 1.2 RELATED WORK A. Section 14 21 00, ELECTRIC
More informationELECTRICAL TESTING TECHNICIAN CERTIFICATION PROGRAM STUDY GUIDE 2017
ELECTRICAL TESTING TECHNICIAN CERTIFICATION PROGRAM STUDY GUIDE 2017 ELECTRICAL TESTING TECHNICIAN CERTIFICATION PROGRAM STUDY GUIDE Table of Contents About the Exams... 1 Level 2... 1 Level 3... 2 Level
More informationITC 2000 HEATING CONTROL CABINET. Installation & Operation Manual
ITC 2000 HEATING CONTROL CABINET Installation & Operation Manual VTI, Incorporated 24 McMillan Way Newark, DE 19713 Phone (302) 738 0500 FAX (302) 738 6594 Revision Level 0.03 Manual No. 90003314 June,
More informationNational Grid Requirements for Interconnection of Parallel Generation
National Grid Requirements for Interconnection of Parallel Generation ESB 756 2017 Revision Review of Changes for RI Jurisdiction, version August 23, 2017 By: National Grid, Retail Connections Policy &
More informationPOWER UP WITH TP ELECTRIC, INC.
POWER UP WITH TP ELECTRIC, INC. A TPE Industries Company NATURAL GAS & OIL ELECTRICAL CONTRACTORS Compressor Stations Gas Processing Plants Rail Terminals Substations Metering Stations Utility Transmission
More information1S25. Arc Fault Monitor 4 Zones, 8 Sensors. Features. Introduction. ARC Fault Protection
Technical Bulletin Arc Fault Monitor 4 Zones, 8 Sensors Features Four independent arc fault tripping zones 1 or 2 arc fault sensors per zone allowing up to 8 arc fault sensors per module Trip indication
More informationStandard PRC-005-3(i) Protection System and Automatic Reclosing Maintenance
A. Introduction 1. Title: Protection System and Automatic Reclosing 2. Number: PRC-005-3(i) 3. Purpose: To document and implement programs for the maintenance of all Protection Systems and Automatic Reclosing
More informationA. Introduction 1. Title: Transmission and Generation Protection System Maintenance and Testing
A. Introduction 1. Title: Transmission and Generation Protection System Maintenance and 2. Number: PRC-005-1b 3. Purpose: To ensure all transmission and generation Protection Systems affecting the reliability
More informationWhat Utility Analytics means to Exelon
What Utility Analytics means to Exelon Presented by Bart Enright IT Director Smart Grid Initiatives at ComEd Exelon s Analytic Journey Exelon Utilities Overview T&D Grids Data Visualization Data Analytics/Notifications
More informationRELEASE DEVICE CONTROLS
RELEASE DEVICE CONTROLS RELEASE DEVICE MODEL C+ INSTALLATION MANUAL UL LISTED CANADIAN LISTED CSFM: 7300-48:00 GENERAL DESCRIPTION: MADE IN THE U.S.A. S/N: The LM0-C+ Release Device/Control Panel is a
More informationPowerohm Resistors Digital HRG System
Installation and Operating Instructions Powerohm Resistors Digital HRG System This manual provides general information, installation, operation, maintenance, and system setup information for the Powerohm
More informationCONTACTORS FOR AEROSPACE GROW SMARTER AND MORE CAPABLE
CONTACTORS FOR AEROSPACE GROW SMARTER AND MORE CAPABLE Karl Kitts, Director of Development Engineering for High Performance Relays AEROSPACE, DEFENSE & MARINE /// WHITE PAPER - CONTACTORS FOR AEROSPACE
More informationELECTRICAL CURRICULA OUTLINE CORE CURRICULUM 2015
ELECTRICAL CURRICULA OUTLINE CORE CURRICULUM 2015 Basic Safety (Construction Site Safety Orientation) (12.5 Hours) (Module ID 00101-15) Presents basic jobsite safety information to prepare workers for
More informationInformational Bulletin on Mobile office Units Prepared by Mark Hilbert May 17, 2017
Informational Bulletin on Mobile office Units Prepared by Mark Hilbert May 17, 2017 It has come to the attention of the electrical authorities having jurisdiction (AHJs) at the DOE sites there is inconsistency
More informationElectrical Hazards and NFPA-70E: Protecting Your Employees
Electrical Hazards and NFPA-70E: Protecting Your Employees Presented By Mark B. Haskins, MS, CSP Practical Safety Solutions, LLC At the CBIA Safety Health and Wellness Conference May 22, 2014 PRESENTATION
More informationWhite Paper SPDs for Essential Power Systems in Health Care Facilities
White Paper s for Essential Power Systems in Health Care Facilities s FOR ESSENTIL POWER SYSTEMS IN HELTH CRE FCILITIES N OVERVIEW OF PROTECTION NEEDS Health care facilities provide critical services to
More informationDISTRIBUTION OPERATIONS AND MAINTENANCE
EB-00-0 Tab Schedule Page of 0 DISTRIBUTION OPERATIONS AND MAINTENANCE PREDICTIVE MAINTENANCE Predictive maintenance expenditures fund work that is required to test and audit distribution system assets.
More informationINSTRUCTION MANUAL T119 1MN0110 REV. 0. operates with ISO9001 certified quality system
INSTRUCTION MANUAL 1MN0110 REV. 0 operates with ISO9001 certified quality system TECSYSTEM S.r.l. 20094 Corsico (MI) Tel.: +39-024581861 Fax: +39-0248600783 http://www.tecsystem.it R. 1.1 25/08/16 ENGLISH
More informationAttention Items: I. Brief Introduction
1 Content Attention Items:... 3 I. Brief Introduction... 3 II. Model Difference... 3 III. Technical Specifications... 4 IV. Detector Structure... 5 V. Network Structure... 5 VI. The Principle and Application
More informationINSTALLATION AND OPERATING INSTRUCTIONS R-3F2-LXX
INSTALLATION AND OPERATING INSTRUCTIONS R-3F2-LXX UL APPROVED FOR: CLASS I, DIVISION 2 HAZ LOC CAT III & IV www.pesd.com Part Number Description: The XX specifies the fiber-o cable length in inches. General
More informationDESIGN AND CONSTRUCTION STANDARDS GENERAL DESIGN GUIDELINES
2.07 ELECTRICAL GENERAL DESIGN AND CONSTRUCTION STANDARDS GENERAL DESIGN GUIDELINES - 2.07 It is expected that the electrical design professional will conform to accepted good engineering design practices.
More informationStandard PRC Protection System and Automatic Reclosing Maintenance. Standard Development Roadmap
Standard Development Roadmap This section is maintained by the drafting team during the development of the standard and will be removed when the standard becomes effective. Development Steps Completed:
More informationINSTRUCTION MANUAL T30 1MN0107 REV. 0. operates with ISO9001 certified quality system
INSTRUCTION MANUAL 1MN0107 REV. 0 operates with ISO9001 certified quality system TECSYSTEM S.r.l. 20094 Corsico (MI) Tel.: +39-024581861 Fax: +39-0248600783 http://www.tecsystem.it R. 1.1 25/08/16 ENGLISH
More informationSafety Standards for Electronic Products
Safety Standards for Electronic Products The following are some of the safety standards for all types of electronic products. ANSI C95.3:1972 / Techniques & instrumentation for measurement of potentially
More informationGuide to Compliance with the Electrical Workplace Safety Standards in the United States
Guide to Compliance with the Electrical Workplace Safety Standards in the United States July 2011/1910DB1102 by Joseph H. Weigel, Product Manager Schneider Electric USA, Inc. Make the most of your energy
More information2014 National Electrical Code & NFPA 70E/Arc Flash
Gain an understanding of the 2014 NEC s latest additions, revisions and changes. Learn the precautions needed when working with and around electricity. People and property need to be safeguarded from the
More informationVACUUM BREAKER MEDIUM VOLTAGE AUTOMATIC TRANSFER SWITCHES
Part One General 1.01 Scope A. It is the intent of this specification to provide a medium voltage automatic transfer system. B. All components, testing and services specified and required for a complete
More informationA. Introduction 1. Title: Transmission and Generation Protection System Maintenance and Testing
A. Introduction 1. Title: Transmission and Generation Protection System Maintenance and 2. Number: PRC-005-1.1b 3. Purpose: To ensure all transmission and generation Protection Systems affecting the reliability
More information7XG3120 ReyArc20 Arc Fault Monitor Relay Energy Management
Reyrolle Protection Devices 7XG3120 ReyArc20 Arc Fault Monitor Relay Energy Management 7XG3120 - Arc Fault Monitor Relay The over-current caused by an arc is, due to its resistance, lower than the over-current
More informationIntroduction Consultant shall incorporate the material in the DSS into the project specifications.
DIVISION 16 - ELECTRICAL Section 16000 - General Discussion Introduction Consultant shall incorporate the material in the DSS into the project specifications. Refer any questions, clarifications regarding
More informationSECTION AUTOMATIC TRANSFER SWITCHES
PART 1 - GENERAL 1.1 DESCRIPTION SECTION 26 36 23 SPEC WRITER NOTE: Use this section only for NCA projects. Delete between //--// if not applicable to project. Also, delete any other item or paragraph
More informationTransmission Line Protection End to End Testing
Transmission Line Protection End to End Testing Hands on Relay School, March 15, 2018 Chris Gallacher Protection Engineer Greg Sharpes Senior Relay Technician Mark Babin Senior Relay Technician Presentation
More information8. Multi-Family Residential Buildings
Mu lti-f a mily Re s id e n tia lbu ild in g s 2016 Electric Service Requirements, 3rd Edition Section 8 Section 8 Multi-Family Residential Buildings Directory Page 8.1 General 61 8.2 Maximum Available
More informationTHE STATE OF NEW HAMPSHIRE BEFORE THE NEW HAMPSHIRE PUBLIC UTILITIES COMMISSION PREPARED TESTIMONY OF LEE LAJOIE AND BRIAN DICKIE
THE STATE OF NEW HAMPSHIRE BEFORE THE NEW HAMPSHIRE PUBLIC UTILITIES COMMISSION PREPARED TESTIMONY OF LEE LAJOIE AND BRIAN DICKIE PUBLIC SERVICE COMPANY OF NEW HAMPSHIRE d/b/a EVERSOURCE ENERGY 0 RELIABILITY
More informationStandard PRC-005-3(X) Protection System and Automatic Reclosing Maintenance
Standard Development Timeline This section is maintained by the drafting team during the development of the standard and will be removed when the standard becomes effective. Development Steps Completed
More informationRE-PR3-E-27 3-Phase Panel Mount 27kW
Page 1 of 6 RE-PR3-E-27 3-Phase Panel Mount 27kW Features: Benefits: 0-10Vdc, 0-5Vdc, 4-20mA or manual via potentiometer control input Over temperature protection with auto reset Enclosed panel mounting
More informationStandard PRC Protection System, Automatic Reclosing, and Sudden Pressure Relaying Maintenance
Standard PRC-005-5 Protection System, Automatic Reclosing, and Sudden Pressure Relaying Maintenance Standard Development Timeline This section is maintained by the drafting team during the development
More informationRelay Performance Index for a Sustainable Relay Replacement Program
Relay Performance Index for a Sustainable Relay Replacement Program Aaron Feathers, Abesh Mubaraki, Nai Paz, Anna Nungo Pacific Gas & Electric Company San Francisco, CA Western Protective Relay Conference
More informationGround Fault Protection Improvement Study
Ground Fault Protection Improvement Study Greg Ball DNV KEMA Solar ABCs Stakeholder Meeting July 11, 2013 San Francisco, CA Study Authors 2 Bill Brooks Brooks Engineering Andy Rosenthal New Mexico State
More informationNEC Requirement Guidelines 2002 Code Options for the Installation of Listed Less-Flammable Liquid-Filled Transformers
NEC Requirement Guidelines 2002 Code Options for the Installation of Listed Less-Flammable Liquid-Filled Transformers BULLETIN 92046 APPLICATION INFORMATION NOVEMBER 2002 SUPERSEDES August 2002 CONTENTS
More informationHESNI ANNUAL CONFERENCE May 3, 2012 Aramark Conference Center, Downers Grove
HESNI ANNUAL CONFERENCE May 3, 2012 Aramark Conference Center, Downers Grove Jim Dungar, P.E. Principal Engineer Schneider Electric Engineering Services Jim.dungar@schneider-electric.com (920-766-8012)
More informationSynchrophasor Technology in Control Centers Clemson University, SC March 12, 2014 Vikram S. Budhraja
Clemson University Power Systems Conference Synchrophasor Technology in Control Centers Clemson University, SC March 12, 2014 Vikram S. Budhraja Outline Synchrophasor Technology Infrastructure Lessons
More informationD-TEK O P E R A T I N G I N S T R U C T I O N S V E HI C L E L O O P DETECTOR Johnston Parkway, Cleveland, Ohio 44128
O P E R A T I N G I N S T R U C T I O N S D-TEK V E HI C L E L O O P DETECTOR 4564 Johnston Parkway, Cleveland, Ohio 44128 P. 800 426 9912 F. 216 518 9884 Sales Inquiries: salessupport@emxinc.com Technical
More informationJune 4, 2014 VIA ELECTRONIC FILING. Ms. Kimberly D. Bose Secretary Federal Energy Regulatory Commission 888 First Street, NE Washington, D.C.
June 4, 2014 VIA ELECTRONIC FILING Ms. Kimberly D. Bose Secretary Federal Energy Regulatory Commission 888 First Street, NE Washington, D.C. 20426 RE: Errata to Petition of the North American Electric
More informationNextGen SCADA Europe 2013
NextGen SCADA Europe 2013 Thursday 21st & Friday 22nd March 2013 Holiday Inn Amsterdam, Netherlands Brian Tapley Manager, HV Operations, North Distribution Control Centre, Ireland 1 Presentation Overview
More informationConstruction Electrical
INDEECO offers a broad range of electrical components for temperature, safety, and power control. For most applications, the Control Option system, described in the previous section, makes it easy to specify
More informationPreliminary Operations and Maintenance Plan Baron Winds Project
Preliminary Operations and Maintenance Plan Baron Winds Project August 2017 Table of Contents 1. Introduction... 3 2. O&M Philosophy and Process... 3 3. Typical O&M Responsibilities and Maintenance Schedules...
More informationA. Introduction 1. Title: Transmission and Generation Protection System Maintenance and Testing
A. Introduction 1. Title: Transmission and Generation Protection System Maintenance and 2. Number: PRC-005-1.1b 3. Purpose: To ensure all transmission and generation Protection Systems affecting the reliability
More informationSOLAR POWER PLANT AUTOMATIO
SOLAR POWER PLANT AUTOMATIO ON Submitted by:- I-Logicon Control Automation Pvt Ltd, Bangalore. CONTENTS: 1. Abstract 2. SCADA and Reporting System Architecture 3. SCADA Components 4. Reporting System.
More informationRelease of Updated Training Standard Log Book
Release of Updated Training Standard Log Book Trade Name & Code Implementation Date of New Standard Implementation Plan Impact on Curriculum Standards or Related Trades Training Standard Access Skill(s)
More informationFax (724) Main St.; P. O. Box 248 West Middlesex, PA IMPORTANT NOTICE
Phone (724) 528-9559 Cimco Electronics, Inc. Fax (724) 528-1108 26 Main St.; P. O. Box 248 West Middlesex, PA 16159 Oct., 2002 IMPORTANT NOTICE Dear Customer, We would like to make you aware of a few hardware
More informationELECTRICAL. Level One. Competencies / Objectives MODULE ORIENTATION TO THE ELECTRICAL TRADE MODULE ELECTRICAL SAFETY
National Center for Construction Education & Research 3600 N.W. 43rd St., Bldg. G, Gainesville, FL 32606 Tel: (352) 334-0911 Fax: (352) 334-0932 E-mail: info@nccer.org ELECTRICAL Competencies / Objectives
More informationElectrical Design Guidelines Table of Contents
C: Compliant Rev. 3 Dated June 13 11 NC: Non-Compliant NA: Not Applicable Page1 16.1 General 16.2 Single Line Diagrams 16.3 Electric Motor Equipment and Controls 16.4 Lighting 16.5 Emergency Lighting 16.6
More informationSubject Description Form
Subject Description Form Subject Code Subject Title Credit Value IC259 IC Training for BSE II 8 Training Credits Level 2 Pre-requisite / Co-requisite/ Exclusion Objectives Nil 1) To provide trainees with
More informationHealthcare Electrical Reference Architecture for Large Hospitals in North America
Healthcare Electrical Reference Architecture for Large Hospitals in North America Catalog 0100CT1803 2018 schneider-electric.com/ecostruxure EcoStruxureTM Power Electrical Reference Architecture for Large
More informationPowerWave 2 Busway System
PowerWave 2 Busway System Guide Specifications (Revision 004, 11/17/2017) 1 GENERAL 1.1 Summary This specification covers the electrical characteristics and general requirements for a continuous opening,
More informationSafety Meeting Topic #37 NFPA 70E What is it?
Safety Meeting Topic #37 NFPA 70E What is it? The National Fire Protection Association (NFPA) 70E is the standard for Electrical Safety Requirements for Employee Workplaces and is a supplement to the NFPA70
More informationNational Grid / Supplement to Specifications for Electrical Installations / ESB ver Doc. File: ESB _ver3_
National Grid / Supplement to Specifications for Electrical Installations / ESB 756-2017 ver. 3.0 Doc. File: ESB756--0617_ver3_0 08-03-2017.docx PREFACE ESB 756-2017 references all requirements for parallel
More informationEE034: Electrical Maintenance for Engineers & Technicians
EE034: Electrical Maintenance for Engineers & Technicians EE034 Rev.001 CMCT COURSE OUTLINE Page 1 of 6 Training Description: We have taken all the latest techniques and know-how relating to electrical
More informationElectrical. Bi-Metallic Thermal Cutouts. Linear Thermal Cutouts
Standard Construction Control Options HEATREX offers a broad range of electrical components for temperature, safety, and power control. For most applications, the Control Option system, described in the
More informationArc Flash Mitigation Solutions: A Proactive Approach To Arc Flash Risk
Arc Flash Mitigation Solutions: A Proactive Approach To Arc Flash Risk Unrestricted Siemens Industry, Inc. 2015 All rights reserved. usa.siemens.com/arc-flash Everyone is concerned about the risk of Arc
More informationSECTION AUTOMATIC TRANSFER SWITCHES PART 1 - GENERAL
SECTION 16400 AUTOMATIC TRANSFER SWITCHES 1.01 RELATED DOCUMENTS PART 1 - GENERAL A. Drawings and general provisions of Contract, including General Conditions and Division 1 Specification sections, apply
More informationVeriSafe Absence of Voltage Tester The safe way to verify the absence of voltage
VeriSafe Absence of Voltage Tester The safe way to verify the absence of voltage www.panduit.com/verisafe What is an Absence of Voltage Tester? Absence of Voltage Testers (AVTs) are permanently-mounted
More informationCurrent transformers. Overview standardization. CIGRE B5 Workshop Stroomtransformatoren 26 Januari 2011 Marc Achterkamp (KEMA TIC en lid NEC38)
Current transformers Overview standardization CIGRE B5 Workshop Stroomtransformatoren 26 Januari 2011 Marc Achterkamp (KEMA TIC en lid NEC38) Question? How thinks to be up to date with (inter)national
More informationMASTER JOCKEY PUMP CONTROLLER. Model JPCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc
MASTER JOCKEY PUMP CONTROLLER Model JPCE INSTRUCTION MANUAL C 2018 Master Control Systems, Inc TABLE OF CONTENTS Important Safety Information. Page 3 General Description and Installation.. Page 4 Model
More informationPROTECTING AGAINST ARC FLASH HAZARDS
PROTECTING AGAINST ARC FLASH HAZARDS Presented by: Andrew J. Fitzpatrick, P.E. Electricity Simply stated electricity is the flow of electrons Electricity is governed by laws: Ohms Law : V=IR Kirchoff s
More informationStandard PRC-005-X Protection System, Automatic Reclosing, and Sudden Pressure Relaying Maintenance
Standard Development Timeline This section is maintained by the drafting team during the development of the standard and will be removed when the standard becomes effective. Development Steps Completed
More informationFreeze Protection Thermostat TRACON MODEL GPT 3 Installation and Operation Manual
MANUAL We manage heat Freeze Protection Thermostat TRACON MODEL GPT 3 Installation and Operation Manual Environmental Technology, Inc. 1850 N Sheridan Street South Bend, Indiana 46628 http://www.networketi.com/
More informationPilz Safety Lockout System (PSLS)
Pilz Safety Lockout System (PSLS) An alternative isolation method for LOTO By Doug Sten, Safety Consultant, Pilz Automation Safety Objectives Challenges with manual, mechanical isolation disconnects Challenges
More informationIEEE Transformer Committee PC Distribution Transformer Monitoring - User
IEEE Transformer Committee PC57.167 Distribution Transformer Monitoring - User Mark Scarborough Electrical Engineering Consultant DuPont January 9, 2019 Transformer Types in DuPont Control power Dry-type
More informationContents The IET Regulations, BS 7671, and this Guide 1.1 The need for this Electrician s Guide 1.2 The IET Regulations BS 7671
Contents 1 The IET Regulations, BS 7671, and this Guide 1 1.1 The need for this Electrician s Guide 1 1.2 The IET Regulations BS 7671 2 1.2.1 International basis 2 1.2.2 The Seventeenth Edition 3 1.2.3
More informationSECTION PANELBOARDS. A. Drawings and general provisions of the Contract, including General and Supplementary Conditions, apply to this Section.
PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions, apply to this Section. 1.2 SUMMARY A. This Section includes the
More informationThree Terminal 230kV System Protection and Restoration at Calpine s Creed and Goose Haven Energy Centers Suisun City, California
Three Terminal 230kV System Protection and Restoration at Calpine s Creed and Goose Haven Energy Centers Suisun City, California Larry Henriksen POWER Engineers, Inc. Hailey, Idaho Daren Phelps Calpine
More informationPRC-005. Tips and Updates. February 25th, Jonathan Hayes
PRC-005 Tips and Updates February 25th, 2014 Jonathan Hayes jhayes@spp.org 501.614.3509 NERC Standards Violations 3 Overview PRC-005-1 Current Issues / Best Practices PRC-005-2 Standard Implementation
More informationINTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 60364-4-44 Edition 1.1 2003-12 Edition 1:2001 consolidated with amendment 1:2003 Electrical installations of buildings Part 4-44: Protection for safety Protection against voltage
More informationLecture 4 Power System Protection. Course map
Lecture 4 Power System Protection 1 Course map 2 1 Outline of the Lecture Relays and IEDs Protection Principles Protection requirements Protection Schemes 3 What can we control? Breakers Valves Tap changers
More informationPlease refer to the drawing and notes for each particular plan view. Site Plan S1-1 Site Drawing. Electrical E1-1 Main Electrical Drawing
The property that I discuss is an actual property that I helped to build. My position was as the Facility/Project Manager while the building was under construction. I worked very closely with the Senior