4010 Fire Alarm Parts List

Size: px
Start display at page:

Download "4010 Fire Alarm Parts List"

Transcription

1 4010 Fire Alarm Parts List Introduction This publication lists the service parts for the 4010 Fire Alarm Control Panel (FACP). Some of the base parts are shown in Figure VAC or /240VAC Transformer Bridge Rectifier /4606 LCD Keyboard Mounting Plate Keyboard (US) (Canada) SFI/O Board Door Lock Figure Fire Alarm Panel 1998 Simplex Time Recorder Co., Gardner, MA USA All Specifications and other information shown were current as of publication, and are subject to change without notice Rev. B

2 Expansion Power Supplies and Chargers Table 1 lists expansion power supplies and charger assemblies for the 4010 FACP. Table 1. Expansion Power Supplies and Charger Assemblies 4010 Expansion Power Supply (120VAC) Expansion Power Supply (220/240VAC) Charger Assembly (120VAC) Charger Assembly (220/240VAC) Suppression Expansion Power Supply (120VAC) Suppression Expansion Power Supply (220/240VAC) Harnesses Table 2 lists Power and Communication Harnesses for the 4010 FACP. Table 2. Harnesses Rectifier Harness (for 4081 Charger) Battery Harness (for 4010 Meter Module) Harness Kit for 25 or 33 Ah Batteries VAC Harness (with one 2-POS Connector) VAC Harness (with two 2-POS Connectors) - Used if Expansion Power Supply is installed Communication Harness - White harness used if Expansion Power Supply is installed Power Harness - Red harness used if Expansion Power Supply is installed Communication Cable N2 Communication Harness (Long) - Harnesses internal communication from SFI/O to Expansion Power Supply VAC Harness (with one 3-POS Connector) VAC Harness (with two 3-POS Connectors) - Used if Expansion Power Supply is installed N2 Communication Harness (Short) - Daisy chains internal communication from expansion slot 1 or Heat Sink Harness,

3 Harnesses (Continued) Table 2. Harnesses (Continued) DACT, Telecom RJ45 Cable Red Jumper Harness - Installed in P13 of SFI/O. Needed if NACS 3 and 4 are powered from the main power supply Harness Kit for 50 Ah Batteries Ω 1/2 Watt N2 Resistor Harness kω 1/2 Watt Class A NAC EOLN Resistor Harness Base and Optional Modules Table 3 lists base system and optional modules for the 4010 FACP. Table 3. Base and Optional Modules 4010/4120 Fiber Optic Media Module /4120 Wired Media Module City Circuit Card Standard Function I/O Board (US) Standard Function I/O Board (Canada) LCD Annunciator Board Class A Adapter Module Expansion Power Supply (PC Board) - Used with 120 VAC, 240 VAC Expansion Power Supply and 240 VAC Suppression Expansion Power Supply 4010 Suppression Expansion Power Supply (PC Board) - Used with 120 VAC Suppression Expansion Power Supply Point Reporting DACT Module Point I/O Card Dual RS232 Module RS232/Modem Module Expansion Charger (PC Board) - Used with 120 VAC and 240 VAC Expansion Charger 4010/4120 Network Interface Module (Accepts RS485 and Fiber Optic Modules) /4120 Network Interface Module (RS485 Only) Event Reporting DACT

4 Base and Optional Modules (Continued) Table 3. Base and Optional Modules (Continued) 4606 and by 40 Character LCD LCD Annunciator Assembly Battery Meter Module Assembly Firmware, Software, and Programmer Table 4 lists the Firmware, Software, and Programmer used with the 4010 FACP. Table 4. Firmware, Software, and Programmer DACT Card Network Card Remote LCD Annunciator RS-232/Modem Card IDNet Controller (PIC Chip) Boot Code SFI/O Controller Point I/O Card Executive Software (.BIN File) Executive Software, French (.BIN File) Executive Software, Australia (.BIN File) PLCC Chip Extractor PC Programmer CD-ROM PC Programmer Floppies Miscellaneous Table 5 lists the batteries, fuses, etc. found in the 4010 FACP. Table 5. Miscellaneous Items Battery 6.2Ah Battery 10Ah Battery 12.7Ah Battery 25Ah Nylon Snap Post - Used if Class A Adapter Module is installed

5 Miscellaneous (Continued) Table 5. Miscellaneous Items (Continued) 15A Slo-Blow Fuse A Fuse Fuse Holder, 120 VAC Inline Fuse Package Fuse VAC or Less, Part of 120 VAC Inline Fuse Package Cover - Used with 120 VAC Inline Fuse Package B-Key CAM Door Lock Voltmeter Ammeter Bridge Rectifier Pluggable Terminal Block (6-Position) Pluggable Terminal Block (3-Position) Terminal Block (3-Position) Keyswitch (for 4606 LCD Annunciator) VAC Transformer - Used with Expansion Power Supply 220VAC Transformer - Used with Expansion Power Supply Ferrite Bead Kit Suppression Power Supply Kit, 120 VAC Suppression Power Supply Kit, 240 VAC Expansion Power Supply Mounting Plate City Circuit Board Mounting Plate Window (Grey) Window (Brown) Door Assembly (Beige) Door Assembly (Red) Expansion Power Supply Chassis Assembly

6 Miscellaneous (Continued) Table 5. Miscellaneous Items (Continued) 120 VAC Transformer and Suppression Power Supply - Used with 4081 Battery Charger and 4010 Fire Alarm Control Panel 220 VAC Transformer and Suppression Power Supply - Used with 4081 Battery Charger and 4010 Fire Alarm Control Panel Varistor - Used when External Auxiliary Power is used kω NAC EOLN Resistor kω City Circuit Resistor LCD Annunciator Light Pipe Rev. B

Network Display Unit Installation Instructions

Network Display Unit Installation Instructions Network Display Unit Installation Instructions Introduction This publication describes the installation procedures for the optional Network Display Units (NDUs). This product is compatible with both the

More information

4100U City and Relay Cards Installation Instructions

4100U City and Relay Cards Installation Instructions 4100U City and Relay Cards Installation Instructions Introduction This publication describes the installation procedure for the following: 4100-6031/6032 City Circuit Cards 4100-6033 Alarm Relay Card Inspecting

More information

/9308 External Battery Chargers Installation Instructions

/9308 External Battery Chargers Installation Instructions 4081-9306/9308 External Battery Chargers Installation Instructions Introduction This publication describes the installation procedure for an External Battery Charger used with the 4100U or 4100ES System.

More information

Panel Remote Annunciators Installation Instructions

Panel Remote Annunciators Installation Instructions Panel Remote Annunciators Installation Instructions Introduction This publication describes the installation procedures for the following PIDs: 4100-9607 Remote Annunciator w/ Flexible User Interface Domestic

More information

30.45 Electric Release PDRP-2001

30.45 Electric Release PDRP-2001 The PDRP-2001 Fire Alarm Control Panel (FACP) is a six-zone control panel for single and dual hazard deluge and preaction applications. The FACP is compatible with conventional input devices (2-wire or

More information

4010 Fire Alarm PC Programmer Installation and Programming Instructions

4010 Fire Alarm PC Programmer Installation and Programming Instructions 4010 Fire Alarm PC Programmer Installation and Programming Instructions 574-187 Rev. C Copyright and Trademarks Copyright Simplex Time Recorder Co., 2000. All rights reserved. Printed in the United States

More information

LifeAlarm Fire Alarm Control Panels

LifeAlarm Fire Alarm Control Panels LifeAlarm Fire Alarm Control Panels UL, ULC Approved* Features Control panel operator convenience features: Wide viewing angle 2 x 20 (40 character) alphanumeric LCD and dedicated LEDs provide convenient

More information

Addressable Fire Alarm Control Panel

Addressable Fire Alarm Control Panel PRODUCT SPECIFICATION XR2400F Addressable FACP Addressable Fire Alarm Control Panel Description The DMP XR2400F Addressable Fire Alarm Control Panel is an expandable Fire Alarm Control with built-in DACT

More information

Cautions and Warnings. Introduction 4009 NAC POWER EXTENDER

Cautions and Warnings. Introduction 4009 NAC POWER EXTENDER Cautions and Warnings DO NOT INSTALL ANY SIMPLEX PRODUCT THAT APPEARS DAMAGED. Upon unpacking your Simplex product, inspect the contents of the carton for shipping damage. If damage is apparent, immediately

More information

4007ES Fire Control Panels

4007ES Fire Control Panels UL, ULC, CSFM Listed; FM, NYC Fire Dept Approved* 4007ES Fire Control Panels 4007ES Hybrid, Fire Detection and Control Panel with Addressable and/or Conventional Initiation Features Satisfies a variety

More information

TrueAlarm Addressable Fire Alarm Control Panels

TrueAlarm Addressable Fire Alarm Control Panels FIRE FIRE SUPERVISORY PREVIOUS MENU NEXT SUPV SUPERVISORY PREVIOUS MENU NEXT SUPV SILENCED SILENCE DISABLE ENABLE FUNCTION EXIT CLEAR ENTER SILENCED SILENCE DISABLE ENABLE FUNCTION EXIT CLEAR ENTER AC

More information

Fire Control Panels. Addressable Fire Detection and Control Basic Panel Modules and Accessories. UL, ULC, CSFM Listed; FM, NYC Fire Dept Approved*

Fire Control Panels. Addressable Fire Detection and Control Basic Panel Modules and Accessories. UL, ULC, CSFM Listed; FM, NYC Fire Dept Approved* Fire Control Panels UL, ULC, CSFM Listed; FM, NYC Fire Dept Approved* Features Basic system includes: Capacity for up to 248 addressable devices, up to 127 VESDA SLI points, up to 2000 points of Annunciation

More information

MODUL-R FIRE ALARM CONTROL PANELS. MR-2900/MR-2920 Addressable Fire Alarm Control Panels MEA. Features. Description

MODUL-R FIRE ALARM CONTROL PANELS. MR-2900/MR-2920 Addressable Fire Alarm Control Panels MEA. Features. Description MODUL-R FIRE ALARM CONTROL PANELS MR-2900/MR-2920 Addressable Fire Alarm Control Panels Description MR-2900 Fire Alarm Control Panel The MR-2900 fire alarm system control unit is the heart of a sophisticated

More information

Fire Control Panels. Addressable Fire Detection and Control Basic Panel Modules and Accessories. UL, ULC, CSFM Listed; FM, NYC Fire Dept Approved*

Fire Control Panels. Addressable Fire Detection and Control Basic Panel Modules and Accessories. UL, ULC, CSFM Listed; FM, NYC Fire Dept Approved* Fire Control Panels UL, ULC, CSFM Listed; FM, NYC Fire Dept Approved* Addressable Fire Detection and Control Basic Panel Modules and Accessories Features Basic system includes: Capacity for up to 250 addressable

More information

FireNET Plus Wiring Instructions

FireNET Plus Wiring Instructions FireNET Plus Wiring Instructions This manual provides wiring instructions for the 1 loop and 2 loop version of the FireNET Plus panels, which supports our finest Hochiki s DCP protocol. Note: Refer to

More information

Fire Control Units. Addressable Fire Detection and Basic Control Unit Modules and Accessories. UL, ULC Listed, FM Approved* Features

Fire Control Units. Addressable Fire Detection and Basic Control Unit Modules and Accessories. UL, ULC Listed, FM Approved* Features Fire Control Units UL, ULC Listed, FM Approved* Features Basic system includes: Capacity for up to 1000 addressable IDNet points, up to 127 VESDA Air Aspiration Systems interface points and up to 254 addressable

More information

Conventional Releasing Control Panel

Conventional Releasing Control Panel s Data Sheet Fire Safety Products Conventional Releasing Control Panel Pre-Action Deluge Agent-Releasing Fire System Model TXR-320 Remote configurable Up to two (2) hazard areas Operable with the following:

More information

/5121/5122 TrueAlert Power Supply Installation Instructions

/5121/5122 TrueAlert Power Supply Installation Instructions 4100-5120/5121/5122 TrueAlert Power Supply Installation Instructions Introduction This publication provides an overview of the features, specifications, and capabilities of the TrueAlert power supplies

More information

TrueAlarm Fire Alarm Controls

TrueAlarm Fire Alarm Controls TrueAlarm Fire Alarm Controls UL, ULC Listed; FM, CSFM, and Model 4010 Fire Alarm Control Panel for NYC, MEA Approved* TrueAlarm Analog Sensors and IDNet Addressable Devices Features Up to 250 addressable

More information

4010 Fire Alarm Front Panel Installing, Operating, and Programming Instructions

4010 Fire Alarm Front Panel Installing, Operating, and Programming Instructions 4010 Fire Alarm Front Panel Installing, Operating, and Programming Instructions 574-052 Rev. F This page intentionally blank Copyright and Trademarks Copyright Simplex Time Recorder Co., 2000. All rights

More information

LifeAlarm Fire Alarm Controls

LifeAlarm Fire Alarm Controls UL, ULC Approved* LifeAlarm Fire Alarm Controls 4009 IDNet NAC Extender for Control with IDNet Communications or Conventional NACs Features Provides additional notification appliance circuit (NAC) capacity

More information

GE Security. FP1200, FP2000 and KSA1200 series fire panels, repeaters and emulators Interconnection and wiring

GE Security. FP1200, FP2000 and KSA1200 series fire panels, repeaters and emulators Interconnection and wiring GE Security FP1200, FP2000 and KSA1200 series fire panels, repeaters and emulators Interconnection and wiring Version v2-2 / September 2005 Aritech and Kilsen are GE Security brands. http://www.geindustrial.com/ge-interlogix/emea

More information

NETWORK FIRE ALARM CONTROL PANEL. Features

NETWORK FIRE ALARM CONTROL PANEL. Features NETWORK FIRE ALARM CONTROL PANEL FX-2009-12N Description FX-2009-12N in a BB-5008 enclosure. Mircom s FleX-Net TM FX-2009-12N Network Fire Alarm Control Panel offers modular components to meet a wide variety

More information

This wiring diagram describes circuit connections for all models of the Series Quaestor-SZU Releasing Fire Control

This wiring diagram describes circuit connections for all models of the Series Quaestor-SZU Releasing Fire Control File: S8485 Wiring Diagram This wiring diagram describes circuit connections for all models of the Series Quaestor-SZU Releasing Fire Control Panel. The operation of this product is intended for indoor

More information

Fire Control Panels. Addressable Fire Detection and Control Basic Panel Modules and Accessories. UL, ULC, CSFM Listed; FM, NYC Fire Dept Approved*

Fire Control Panels. Addressable Fire Detection and Control Basic Panel Modules and Accessories. UL, ULC, CSFM Listed; FM, NYC Fire Dept Approved* Fire Control Panels UL, ULC, CSFM Listed; FM, NYC Fire Dept Approved* Features Basic system includes: Capacity for up to 250 addressable IDNet points, up to 127 VESDA Air Aspiration Systems interface points,

More information

Fire Safety. Installation Instructions Model SMB-2 Main Control Board OPERATION INSTALLATION

Fire Safety. Installation Instructions Model SMB-2 Main Control Board OPERATION INSTALLATION Fire Safety Installation Instructions Model SMB- Main Control Board OPERATION The SIEMENS Model SMB- board in each MXL-IQ System controls operations and monitors input device identity, network communication,

More information

Fire Control Units. Addressable Fire Detection and Control Basic Control Unit Modules and Accessories. UL, ULC Listed; FM Approved* Features

Fire Control Units. Addressable Fire Detection and Control Basic Control Unit Modules and Accessories. UL, ULC Listed; FM Approved* Features Fire Control Units UL, ULC Listed; FM Approved* Features Compatible with Simplex ES Net and 4120 fire alarm networks Basic System includes: Capacity for up to 998 addressable IDNet points, or up to 1000

More information

Z-20 Fire Control Panels

Z-20 Fire Control Panels MANUAL RELEASE SYSTEM ABORT PUSH AND HOLD - I D N E T I N + + ID N E T I N - RE D NAC+ N A C - BLK C O ILS U P E R V IS IO NM O D U L E ( 2A M P )2 0 8 1-9 0 4 6 IN S T A L L A T IO NIN S T R U C T IO

More information

4009 Fiber Optic Link Option Installation Instructions

4009 Fiber Optic Link Option Installation Instructions 4009 Fiber Optic Link Option Installation Instructions Cautions and Warnings DO NOT INSTALL ANY SIMPLEX PRODUCT THAT APPEARS DAMAGED. Upon unpacking your Simplex product, inspect the contents of the carton

More information

Release Control Fire Alarm Systems

Release Control Fire Alarm Systems SYSTEM ABORT PUSH AND HOLD COIL SUPERVISION MODULE (2 AMP) 2081-9046 RED INSTALLATION INSTRUCTIONS 574-437 REV YEL NAC+ MAINTAIN 1/4" SEPARATION BETWEEN POWER LIMITED (RED/) AND NONPOWER S LIMITED (YEL/)

More information

4100ES Fire Alarm System

4100ES Fire Alarm System FIRE ALARM 4100ES Fire Alarm System Installation Guide 574-848 Rev. AD Cautions, Warnings, and Regulatory Information Cautions and Warnings READ AND SAVE THESE INSTRUCTIONS- Follow the instructions in

More information

TrueAlarm Fire Alarm Systems

TrueAlarm Fire Alarm Systems OPERATOR OPERATOR OR TROUBLE CONDITION: TO : FIRE PRIORITY 2SYSTEM SYSTEM SIGNALS POWER INDICATOR. SUPERVISORYTROUBLE SILENCED ON D. TO SILENCE SIGNALS: - PRESS " SILENCE". SUPV TBL SYSTEM ACK ACK ACK

More information

4007ES Fire Control Panels

4007ES Fire Control Panels UL, ULC, CSFM Listed; FM, NYC Fire Dept Approved* Features Flexible standard combination of addressable initiation and addressable notification 4.3 (109 mm) Diagonal color touchscreen display: Convenient

More information

LED Driver Module. These instructions contain procedures to follow in order to avoid personal injury and damage to equipment.

LED Driver Module. These instructions contain procedures to follow in order to avoid personal injury and damage to equipment. LED Driver Module Installation Guide 1.0 Notice These instructions are for installing Radionics LED Driver Module in a fire alarm system controlled by Radionics D8024 or D10024 Fire Alarm Control Panels

More information

4100ES Fire Control Panels

4100ES Fire Control Panels 4100ES Fire Control Panels, C, CSFM Listed; FM Approved, MEA (NYC) Acceptance* Features Standard addressable interfaces include: IDNet addressable device interface with 250 points that support True analog

More information

INTELLIGENT FIRE ALARM AND AUDIO NETWORK SYSTEM. Features

INTELLIGENT FIRE ALARM AND AUDIO NETWORK SYSTEM. Features INTELLIGENT FIRE ALARM AND AUDIO NETWORK SYSTEM Description Mircom s FleX-Net TM Series Network Fire Alarm Control Panels offer modular components to meet a wide variety of applications. Designed for peerto-peer

More information

Installation Guide for AL300ULM. Multi-Output Access Control Power Supply Charger

Installation Guide for AL300ULM. Multi-Output Access Control Power Supply Charger Installation Guide for AL300ULM Multi-Output Access Control Power Supply Charger R AL300ULM - Multi-Output Access Control Power Supply/Charger Overview: The AL300ULM multi-output access control power supply/charger

More information

Fire Control Panels. Addressable Fire Detection and Control Basic Panel Modules and Accessories. UL, ULC Listed, FM Approved* Features

Fire Control Panels. Addressable Fire Detection and Control Basic Panel Modules and Accessories. UL, ULC Listed, FM Approved* Features Fire Control Panels UL, ULC Listed, FM Approved* Features Basic system includes: Capacity for up to 1000 addressable IDNet points, up to 127 VESDA Air Aspiration Systems interface points and up to 254

More information

ALARMS Fire Alarm Priority 2 Alarm. Fire Alarm Priority 2. Ack Event Time Enable Disable Emergency Operating Instructions.

ALARMS Fire Alarm Priority 2 Alarm. Fire Alarm Priority 2. Ack Event Time Enable Disable Emergency Operating Instructions. ALARMS Fire Alarm Priority 2 Alarm Fire Alarm Event Time Enable Disable Emergency Operating Instructions Arm Disarm Priority 2 SYSTEM WARNINGS Supervisory Trouble Alarm Silenced Supv More Info Lamp Test

More information

Fire Control Panel FS4000

Fire Control Panel FS4000 Fire Control Panel FS4000 INSTRUCTION MANUAL Revision 4/02.11 Contents 1. Introduction... 4 2. Terminology... 4 3. Function... 5 4. Technical features... 5 4.1 Fire alarm lines... 5 4.2. Current thresholds

More information

MS Rev. 2/DACT-UD: Intelligent Addressable FACP with Optional 2nd Loop

MS Rev. 2/DACT-UD: Intelligent Addressable FACP with Optional 2nd Loop MS-9600 Rev. 2/DACT-UD: Intelligent Addressable FACP with Optional 2nd Loop DF-52395:A A1-90 Addressable General The Fire Lite MS-9600 is a compact, cost-effective, intelligent addressable fire alarm control

More information

Fire Control Panels. Network Annunciator Panels Network Display Unit (NDU) UL, ULC, CSFM Listed; FM Approved; MEA (NYC) Acceptance* Features

Fire Control Panels. Network Annunciator Panels Network Display Unit (NDU) UL, ULC, CSFM Listed; FM Approved; MEA (NYC) Acceptance* Features FIRE PL ALARM DOWN FIRE PL ALARM DOWN Event Time Enable Arm Di sable E mergency Operating Instr uctions Al ar m or War ni ng Co ndi ti on System indicator f lashing. Tone. How to nowledge / View Events

More information

TrueAlarm Fire Alarm Systems

TrueAlarm Fire Alarm Systems TrueAlarm Fire Alarm Systems UL, ULC, CSFM Listed; FM Approved* Features TrueSite Incident Commander provides 4100ES mounting for the Simplex TrueSite Workstation: All-in-one touchscreen computer/monitor

More information

TrueAlarm Fire Alarm Systems

TrueAlarm Fire Alarm Systems TrueAlarm Fire Alarm Systems UL, ULC, CSFM Listed; FM Approved* Features TrueSite Incident Commander provides 4100ES mounting for the Simplex TrueSite Workstation: All-in-one touchscreen computer/monitor

More information

4007ES Fire Control Panels

4007ES Fire Control Panels UL, ULC, CSFM Listed; FM Approved* Features Flexible standard combination of addressable initiation and addressable notification 4.3 (109 mm) Diagonal color touchscreen display: Convenient and intuitive

More information

Multi-Output Access Control Power Supply Charger VDC or 24VDC VDC or 3 24VDC.

Multi-Output Access Control Power Supply Charger VDC or 24VDC VDC or 3 24VDC. M Series Multi-Output Access Control Power Supply Charger Installation Guide Models Include: AL300ULM AL400ULM - 2.5 amp @ 12VDC or 24VDC. - 4 amp @ 12VDC or 3 amp @ 24VDC. AL600ULM AL1012ULM - 6 amp @

More information

Installation Guide for AL400ULM. Multi-Output Access Control Power Supply Charger

Installation Guide for AL400ULM. Multi-Output Access Control Power Supply Charger Installation Guide for AL400ULM Multi-Output Access Control Power Supply Charger R AL400ULM - Multi-Output Access Control Power Supply/Charger Rev. 072500 Overview: The AL400ULM multi-output access control

More information

Installation Guide for AL600ULM. Multi-Output Access Control Power Supply Charger. Rev

Installation Guide for AL600ULM. Multi-Output Access Control Power Supply Charger. Rev Installation Guide for AL600ULM Multi-Output Access Control Power Supply Charger Rev. 091800 1 AL600ULM - Multi-Output Access Control Power Supply/Charger Overview: The AL600ULM multi-output access control

More information

ACCURATE ELECTRONICS INC

ACCURATE ELECTRONICS INC ACCURATE ELECTRONICS INC Page 1 of 7 Model 108078 2 Sept 09 WWW.ACCURATE.ORG PO BOX 1654 97075-1654 8687 SW Hall Blvd 97008 BEAVERTON OR USA 503.641.0118 FAX 503.646.3903 Practice Section 108078 Rev A

More information

Certificate of Conformity Certificate num. Registration date Version Valid until

Certificate of Conformity Certificate num. Registration date Version Valid until CSIRO Verification Services Highett, Victoria, Australia +61 (0)3 9252 6000 http://www.activfire.gov.au/ Page 1 of 7 Product designation Simplex, Model 4100U/4100U-S1/4100ES/4100ES-S1, fire indicator panel

More information

Intelligent 2 & 4 Loop Fire Alarm Control Panels

Intelligent 2 & 4 Loop Fire Alarm Control Panels Intelligent 2 & 4 Loop Fire Alarm Control Panels Advanced has combined the latest technology with many years of fire experience, to create the Axis AX Series Intelligent Fire Alarm Control Panels. The

More information

Added password for IP setup page : Password must be in IP format!

Added password for IP setup page : Password must be in IP format! NETWORK POWER MONITOR Release : 21 August 2014 Hardware Version : Version 7 Firmware version 1.00 PC Application Software : Version (latest)...2 Added password for IP setup page : Password must be in IP

More information

1 INTRODUCTION NOTICE WARNINGS AND CAUTIONS NATIONAL APPROVALS EMC COMPATIBILITY UNPACKING...

1 INTRODUCTION NOTICE WARNINGS AND CAUTIONS NATIONAL APPROVALS EMC COMPATIBILITY UNPACKING... ZXA / ZXE FIRE ALARM CONTROL PANEL MORLEY-IAS Table of Contents 1 INTRODUCTION...1 1.1 NOTICE... 1 1.2 WARNINGS AND CAUTIONS... 1 1.3 NATIONAL APPROVALS... 2 1.4 EMC COMPATIBILITY... 2 2 UNPACKING...3

More information

Intelligent Single Loop Fire Alarm Control Panel

Intelligent Single Loop Fire Alarm Control Panel Intelligent Single Loop Fire Alarm Control Panel The CAX-CTL-1L Intelligent Single Loop Fire Alarm Control Panel is a member of the industry leading Axis AX Series Intelligent Fre Alarm Control Panels

More information

DGC-1000 DIGITAL GENSET CONTROLLER

DGC-1000 DIGITAL GENSET CONTROLLER DGC-1000 DIGITAL GENSET CONTROLLER Basler Electric s Digital Genset Controller (DGC-1000) offers a low cost microprocessor based integrated alternative for small to medium sized genset control and monitoring.

More information

CONVENTIONAL FIRE ALARM CONTROL UNITS. MR-2300 SERIES Fire Alarm Control Units MEA

CONVENTIONAL FIRE ALARM CONTROL UNITS. MR-2300 SERIES Fire Alarm Control Units MEA CONVENTIONAL FIRE ALARM CONTROL UNITS MR-2300 SERIES Fire Alarm Control Units Description Secutron s MR-2300 Series fire alarm control panels consist of six and twelve zone models which are equipped with

More information

Fire Control Panel FS5100

Fire Control Panel FS5100 Fire Control Panel FS5100 INSTRUCTION MANUAL Revision 6/02.11 Contents 1. Introduction... 5 2. Terminology... 5 3. Function... 7 4. Technical data... 7 4.1. Modules... 7 4.1.1. Type of modules... 7 4.1.2.

More information

4007ES and 4007ES Hybrid Fire Alarm Systems Installation Manual

4007ES and 4007ES Hybrid Fire Alarm Systems Installation Manual 4007ES and 4007ES Hybrid Fire Alarm Systems Installation Manual *05791102H* This page is intentionally blank Contents CONTENTS 1 Cautions, Warnings, and Regulatory Information...3 2 Overview...4 2.1 4007ES

More information

Harrington Signal HS-3100/3200 Fire Alarm Control Unit

Harrington Signal HS-3100/3200 Fire Alarm Control Unit HARRINGTON SIGNAL INC. FIRE ALARM Harrington Signal HS-3100/3200 Fire Alarm Control Unit Installation Manual Revision 2 January 2009 Document # LT-2000HAR Table of Contents 1.0 Technical Information...

More information

CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM

CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION Fike s Cheetah Xi (P/N 10-068) is a state-of-the-art true intelligent digital peer-topeer modular suppression control system. It is ideal for

More information

TrueAlarm Fire Alarm Systems

TrueAlarm Fire Alarm Systems TrueAlarm Fire Alarm Systems UL, ULC, CSFM Listed; Fire Alarm Network Annunciators; FM Approved* TrueSite Incident Commander; Version 4.02 Features TrueSite Incident Commander provides 4100ES mounting

More information

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX NDS Intelligent Network Fire Alarm Control Unit. Features. Description

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX NDS Intelligent Network Fire Alarm Control Unit. Features. Description INTELLIGENT FIRE ALARM CONTROL UNITS MMX-2003-12NDS Intelligent Network Fire Alarm Control Unit Description Secutron s MMX-2003-12NDS Network Fire Alarm Control Unit offers modular components to meet a

More information

Multi-Output Access Control Power Supply Chargers VDC or 24VDC VDC or 4 24VDC.

Multi-Output Access Control Power Supply Chargers VDC or 24VDC VDC or 4 24VDC. M Series Multi-Output Access Control Power Supply Chargers Installation Guide Models Include: AL300ULM AL400ULM - 2.5 amp @ 12VDC or 24VDC. - 3 amp @ 12VDC or 4 amp @ 24VDC. AL600ULM AL1012ULM - 6 amp

More information

General Routing Interface

General Routing Interface General Routing Interface Features The General Routing Interface Card is an optional module to provide Fire and Fault Routing Outputs compliant with BSEN54-2: 1998 Clauses 7.9 and 8.9 and BS5839-1: 2002.

More information

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX TM Series Intelligent Fire Alarm & Network System

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX TM Series Intelligent Fire Alarm & Network System INTELLIGENT FIRE ALARM CONTROL UNITS MMX TM Series Intelligent Fire Alarm & Network System MMX-BBX-FXMNSR BB-5014R Description Secutron's MMX TM Series Network Fire Alarm Control Units offer modular components

More information

Reverse Chronological Order by Date of Last Revision... page 2. Numerical Order... page 4. Discontinued/Inactive Data Sheets...

Reverse Chronological Order by Date of Last Revision... page 2. Numerical Order... page 4. Discontinued/Inactive Data Sheets... Simplex Fire Alarm Status 2/15/2016 Reverse Chronological Order by... page 2 Numerical Order... page 4 Discontinued/Inactive s... page 9 page 1 Simplex Fire Alarm Status 2/15/2016 Fire Alarm s in Reverse

More information

1 INTRODUCTION NOTICE WARNINGS AND CAUTIONS NATIONAL APPROVALS EN54 INFORMATION UNPACKING...

1 INTRODUCTION NOTICE WARNINGS AND CAUTIONS NATIONAL APPROVALS EN54 INFORMATION UNPACKING... ZX Fire Alarm Control Panels MORLEY-IAS Table of Contents 1 INTRODUCTION...1 1.1 NOTICE...1 1.2 WARNINGS AND CAUTIONS...1 1.3 NATIONAL APPROVALS...2 1.4 EN54 INFORMATION...2 2 UNPACKING...4 3 INSTALLATION...5

More information

TrueAlarm Fire Alarm Systems

TrueAlarm Fire Alarm Systems TrueAlarm Fire Alarm Systems UL, ULC, CSFM Listed; Fire Alarm Network Annunciators; FM Approved* TrueSite Incident Commander; Version 3.03 Features TrueSite Incident Commander provides 4100ES mounting

More information

SI120 Guarto Easy I. Alarm system. Fire & Security Products

SI120 Guarto Easy I. Alarm system. Fire & Security Products Alarm system SI120 Guarto Easy I Central alarm control unit with integrated communicator Simple to program Simple and reliable to operate Flexible Extensive communications Simple to install Alarm receiving

More information

CONVENTIONAL FIRE ALARM CONTROL PANELS. SFC-200 Series Fire Alarm Control Panels MEA. Features. Description

CONVENTIONAL FIRE ALARM CONTROL PANELS. SFC-200 Series Fire Alarm Control Panels MEA. Features. Description CONVENTIONAL FIRE ALARM CONTROL PANELS SFC-200 Series Fire Alarm Control Panels Description Summit s SFC-200 Series fire alarm control panels consist of six and twelve zone models which are equipped with

More information

IntelliKnight 5820XL Addressable Fire Alarm Control System Sales Guide

IntelliKnight 5820XL Addressable Fire Alarm Control System Sales Guide IntelliKnight 5820XL Addressable Fire Alarm Control System Sales Guide Product Overview The IntelliKnight 5820XL is an intelligent addressable fire alarm control panel designed for flexibility and reliability.

More information

1 UL 864 Compliance. 2 Product Overview. Network Communications Module NCM-W/F Product Installation Document. 1.1 Products Subject to AHJ Approval

1 UL 864 Compliance. 2 Product Overview. Network Communications Module NCM-W/F Product Installation Document. 1.1 Products Subject to AHJ Approval 1 UL 864 Compliance 12 Clintonville Road Northford, CT 06472-1653 USA 203-484-7161 FAX 203-484-7118 www.notifier.com Network Communications Module NCM-W/F Product Installation Document PN 51533:D2 04/13/2012

More information

PFC-4064 Conventional Fire Alarm Panel

PFC-4064 Conventional Fire Alarm Panel PFC-4064 Conventional Fire Alarm Panel Installation, Operations & Programming Manual Potter Electric Signal Company, LLC St. Louis, MO Customer Service: (866) 240-1870 Technical Support: (866) 956-1211

More information

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX NDS Intelligent Network Fire Alarm Control Unit. Features. Description

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX NDS Intelligent Network Fire Alarm Control Unit. Features. Description INTELLIGENT FIRE ALARM CONTROL UNITS MMX-2003-12NDS Intelligent Network Fire Alarm Control Unit Description Secutron's MMX-2003-12NDS is a powerful intelligent networkable fire alarm solution designed

More information

GENERAL STANDARD FEATURES. ISO-9001 Engineering and Manufacturing Quality System Certified to International Standard ISO-9001 PATENT PENDING

GENERAL STANDARD FEATURES. ISO-9001 Engineering and Manufacturing Quality System Certified to International Standard ISO-9001 PATENT PENDING GENERAL The VEC 25/50 is a state-of-the-art, compact, stand-alone or slave Emergency Voice Evacuation Control. The VEC 25/50 is offered in a self-contained, cost-effective design and includes a 25 Watt,

More information

DS3MX-E-I. Installation Guide. 3 Zone Mini Control Panel

DS3MX-E-I. Installation Guide. 3 Zone Mini Control Panel DS3MX-E-I EN Installation Guide 3 Mini Control Panel DS3MX-E-I Installation Guide 1.0 General Information EN 2 1.0 General Information The DS3MX is a three zone mini control panel, which can be installed

More information

Control Panel. 1.0 GENERAL SCOPE OF WORK Introduction... 2

Control Panel. 1.0 GENERAL SCOPE OF WORK Introduction... 2 Architectural & Engineering Specifications Control Panel 1.0 GENERAL... 2 1.1 SCOPE OF WORK... 2 1.1.1 Introduction... 2 1.2 GENERAL CONDITIONS... 2 1.2.1 After-Sales Support... 2 1.2.2 Quality assurance...

More information

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION Fike s CyberCat 254 (P/N 10-066) is a state-of-the-art true intelligent digital peer-to-peer modular fire alarm control system.

More information

LDM Series Lamp Driver Modules For Graphic Annunciation and Control

LDM Series Lamp Driver Modules For Graphic Annunciation and Control 12 Clintonville Road Northford, CT 06472 (203) 484-7161 FAX: (203) 484-7118 LDM Series Lamp Driver Modules For Graphic Annunciation and Control Used with the System 500, System 5000, AM2020/AFP1010 and

More information

Functional Performance Test

Functional Performance Test Fire Alarm Control Panel & Fire Alarm Annunciator Panel Notify all building occupants that testing will be conducted. Fire alarm contractor shall have personnel with 2-way radios at the fire alarm control

More information

NETWORK FIRE ALARM CONTROL PANEL. Features S7010 S :111

NETWORK FIRE ALARM CONTROL PANEL. Features S7010 S :111 NETWORK FIRE ALARM CONTROL PANEL FX-2009-12NDS Description FX-2009-12NDS in a BB-5008R enclosure. Mircom s FleX-Net Series is a powerful intelligent networkable fire alarm solution designed with many levels

More information

MAXSYS Zone Control Panel PC4020. Maxsys Commercial Fire Panel PC4020CF. MAXSYS 16 Output Module PC4216

MAXSYS Zone Control Panel PC4020. Maxsys Commercial Fire Panel PC4020CF. MAXSYS 16 Output Module PC4216 16-128 Zone Control Panel PC4020 16 zones on main control panel supports up to 16 hardwired keypads Expandable up to 128 zones using hardwire, wireless modules and addressable zones COMBUS hardwired expansion

More information

June 10, 2002 DF C S2424

June 10, 2002 DF C S2424 GENERAL www.firelite.com The Fire Lite FIRE COMMAND 25/50X is a state-of-theart Emergency Voice Evacuation Control Panel (VECP), with significant technological enhancements that set it apart from other

More information

ADR Analog Addressable Fire Alarm Control Panel. Technical Manual. Control Panels. 3000En. En pdf

ADR Analog Addressable Fire Alarm Control Panel. Technical Manual. Control Panels. 3000En. En pdf Control Panels Analog Addressable Fire Alarm Control Panel Technical Manual TELEFIRE FIRE & GAS DETECTORS LTD PO Box 7036 Petach Tikva 49250 Israel Tel: 972 3 970 0400 Fax: 972 3 921 1816 email: Web: info@telefire.co.il

More information

Fratech Multipath-IP

Fratech Multipath-IP Rev 2.0 (May 2013) Installer Manual 1 Current Part Numbers: Fratech Multipath-IP E-Link STU PCB & Accessory Kit only In Metal Enclosure with Power Supply 998325-PK 998325-XS Installer Manual This document

More information

AL800ULADA. NAC Power Extender. Installation Guide

AL800ULADA. NAC Power Extender. Installation Guide AL800ULADA NAC Power Extender Installation Guide Rev. 122000 AL800ULADA - NAC Power Extender Overview: The Altronix AL800ULADA is an extremely cost effective 8 amp voltage regulated remote power supply/battery

More information

20 Light Remote Annunciator

20 Light Remote Annunciator Light Remote Annunciator Owner s Manual Surface Mount Flush Mount 94-95- Standard Annunciator 94-, 94-95-, 95-4- 4- Annunciator w/remote Relay Panel 4-, 4-4-, 4-49-, 49-49-, 49- Time Multiplexed Annunciator

More information

ACC-25/50ZST. Zoned System Voice with Telephone Evacuation Control Panel

ACC-25/50ZST. Zoned System Voice with Telephone Evacuation Control Panel ACC-25/50ZST Zoned System Voice with Telephone Evacuation Control Panel General The AUDIO COMMAND CENTER 25/50 Zone System with FireFighters Telephone (ACC-25/50ZST) is a state-of-the-art Emergency Voice

More information

July 14, 1999 DF C-100.

July 14, 1999 DF C-100. www.firelite.com GENERAL The Fire Lite FIRE COMMAND 25/50 is a state-of-theart, compact, stand-alone or slave Emergency Voice Evacuation Control Panel (VECP). The FIRE COMMAND 25/50 is offered in a self-contained,

More information

TrueAlert Addressable Notification Appliances

TrueAlert Addressable Notification Appliances Fire Control ** IS NORMAL ** :0:pm Mon 9-Feb-9 SY S TE M AC SUPERVISORY TROUB LE SILENCED SUPV TROUBLE SILENCE RESET CONTROL DISC ON NEC T POW ER + V ZONE P WR + 0V ZONE P WR - +IDNE T IDC + - IDNE T IDC

More information

Desigo TM Fire Safety System A comprehensive fire-protection system

Desigo TM Fire Safety System A comprehensive fire-protection system s Desigo TM Fire Safety System A comprehensive fire-protection system Standard 252-point and 504-point capacity systems Remote viewing for the 252- point and 504-point systems One (1) or (2) two-heightunit

More information

YOUR PARTNER IN FIRE & GAS DETECTION

YOUR PARTNER IN FIRE & GAS DETECTION YOUR PARTNER IN FIRE & GAS DETECTION OGGIONI s.a.s. Via Lavoratori Autobianchi, 1 - P.T.B. Edif.13/O - 20832 Desio (MB) Italy Tel.+39 0362 629135 Fax. +39 0362 622531 www.oggionisas.com - info@oggionisas.com

More information

Desigo TM Fire Safety System A comprehensive fire-protection system

Desigo TM Fire Safety System A comprehensive fire-protection system s Desigo TM Fire Safety System A comprehensive fire-protection system Standard 50-point, 252-point and 504-point-capacity systems Remote viewing for the 252- point and 504-point systems One (1) or (2)

More information

4010 Fire Alarm Applications Manual

4010 Fire Alarm Applications Manual 4010 Fire Alarm Applications Manual 574-908 Rev. A Copyright and Trademarks Copyright Simplex Time Recorder Co., 1999. All rights reserved. Printed in the United States of America. Information in this

More information

Cerberus PRO A comprehensive fire-protection system

Cerberus PRO A comprehensive fire-protection system Cerberus PRO A comprehensive fire-protection system Cerberus TM ARCHITECT AND ENGINEER SPECIFICATIONS Standard 252-point and 504-point fire systems Remote viewing for the 252- point and 504-point systems

More information

/ XPS Interconnection Diagrams

/ XPS Interconnection Diagrams 4100-5153/4100-5154 XPS Interconnection Diagrams Introduction This publication provides interconnection diagrams for 4100-5153 (120 VAC) and 4100-5154 (220/240 VAC) 13 A Expansion Power Supplies (XPS).

More information

TrueAlarm Fire Alarm Controls

TrueAlarm Fire Alarm Controls FIRE ALARM ALARMS S DISABLEMENT DISABLED ZONES SITE SPECIFIC PROGRAMMABLE KEYS/LEDS S /DISABLED SILENCED DISABLE/ENABLE S SILENCE/RESOUND SYSTEM PULL DOOR TO OPEN RESET PANEL SILENCE POWER INDICATION OF

More information

INTELLIGENT FIRE ALARM AND AUDIO NETWORK SYSTEM S7010 S :111

INTELLIGENT FIRE ALARM AND AUDIO NETWORK SYSTEM S7010 S :111 INTELLIGENT FIRE ALARM AND AUDIO NETWORK SYSTEM BBX-FXMNSR BBX-5014R Description Mircom s FleX-Net Series is a powerful intelligent networkable fire alarm solution designed with many levels of flexibility

More information

FCPS-24F FIRE ALARM FIELD CHARGER/POWER SUPPLY FOR FIRE PROTECTION/SIGNALING SERVICE FCPS-24F/FCPS-24FE. Field Charger/Power Supply

FCPS-24F FIRE ALARM FIELD CHARGER/POWER SUPPLY FOR FIRE PROTECTION/SIGNALING SERVICE FCPS-24F/FCPS-24FE. Field Charger/Power Supply One Fire-Lite Place Northford, CT 06472 Phone: (203) 484-7161 FAX: (203) 484-7118 FCPS-24F FIRE ALARM FIELD CHARGER/POWER SUPPLY FOR FIRE PROTECTION/SIGNALING SERVICE FCPS-24F/FCPS-24FE Field Charger/Power

More information

Supplement to The PDRP-1001/PDRP-1001A/PDRP-1001E Deluge Preaction Control Panel Manual

Supplement to The PDRP-1001/PDRP-1001A/PDRP-1001E Deluge Preaction Control Panel Manual Supplement to The PDRP-1001/PDRP-1001A/PDRP-1001E Deluge Preaction Control Panel Manual Replace the following pages of Document Number 50734 (I56-993-01/D770-19-00), Revision B with the corresponding revised

More information