1 INSTALLATION AND INSTRUCTION MANUAL FOR TM-16 EMERGENCY WARNING SYSTEM SPECIAL NOTE BOONE CABLE WORKS & ELECTRONICS, INC TH LANE P.O. BOX 429 READ THIS ENTIRE BOOKLET BOONE, IOWA USA BEFORE PROCEEDING WITH PHONE (515) FAX (515) THE INSTALLATION TOLL FREE NUMBER Web Address: (rolfesatboone.com)
2 TABEL OF CONTENTS 1. General 2. Instrument (Battery Powered) 3. Instrument (110 VAC Powered) 4. Wiring Runs, Color Coded and Splices 5. Sensors A. Probe B. Belt Alignment C. Surface D. Fire Detection 6. Operating Instructions 1
3 1. General Boone Cable Works & Electronics, Inc. offers a comprehensive line of temperature monitoring equipment. This complete product range and our extensive systems experience allows us to offer effective solutions for a wide range of solutions for your individual system requirements. Our extensive background in temperature monitoring along with a constant program of innovation and technological development allows us to offer cost-effective and user-orientated solutions. Please read all the instructions for system installation before beginning. 2. TM Instrument (Battery Powered) The instrument is in a Nema 13 enclosure, which offers protection against dust, spraying of water and oil in an indoor environment. It features a hinged clear polycarbonate cover for easy viewing and accessibility. Two locking screws are provided on the cover to secure it in place. Refer to the Hoffman installation instructions included with the unit before mounting the enclosure. To mount, remove the instrument splice compartment cover that is attached by two screws. (See drawing A) Disconnect the battery pack. Remove the instrument panel, which is secured with four screws. The instrument is mounted with three mounting holes. Fasten the instrument using the top hole. Then level the instrument and secure it with the mounting holes at either end of the splice compartment cover. Reassemble the instrument. Inside on the left side of the splice compartment there are two TM 9 conductor wires, which have a black jacket. (Lead #1 is for sensors 1 through 8 and lead #2 is for sensors 9 through 16). They are spliced color to color with the TM wires from the sensors. The unit is powered by a single 9 volt battery. The Battery compartment is also located behind the splice compartment cover. 2
4 3. TM Instrument (110 VAC Powered) The instrument is in Nema 13 enclosure, which offers protection against dust, spraying of water and oil in an indoor environment. It features a hinged clear polycarbonate cover for easy viewing and accessibility. Two locking screws are provided on the cover to secure it in place. Refer to the Hoffman installation instructions included with the unit before mounting the enclosure. To mount, remove the instrument splice compartment cover that is attached by two screws. (See drawing A) Remove the instrument panel, which is secured with four screws. The instrument is mounted with three mounting holes. Fasten the instrument using the top hole. Then level the instrument and secure it with the mounting holes at either end of the splice compartment cover. Reassemble the instrument. Inside on the left side of the splice compartment there are two TM 9 conductor wires, which have a black jacket. (Lead #1 is for sensors 1 through 8 and lead #2 is for sensors 9 through 16). They are spliced color to color with the TM wires from the sensors. Located on the right side of the splice compartment are two terminal blocks. Attach 110 VAC or 220 VAC depending on which input/power voltage was selected when ordering. See serial number decal if unsure. If the instrument is configured for 220 VAC then attach one power line to N and the other power line to L. If the instrument is configured for 110 VAC then attach the neutral line to N and the power line to L. For both 110 VAC and 220 VAC attach earth ground to GND. The second terminal block provides normally open (NO) and normally closed (NC) contacts that change state when the BF enters an alarm condition. Use either the common (C) to NO or C to NC contact. Do not use both the NO and NC contacts. The contacts are rated at 125 VAC at 1 amp, resistive load. At the bottom of the enclosure are conduit knockouts that are removed to run wires to the instrument. 3
5 4. Wiring Runs, Color Coded and Splices The Instrument, which can monitor 16 sensors, has two TM wires in its splice compartment. The wire marked #1 is for zones 1 through 8. The wire marked #2 is for zones 9 through 16. The wire is run from the instrument to within 5 feet of each sensor. Strap and mount the wire so that it is exposed to the least amount of physical and environmental stress. The most desirable method is to enclose all wires in a dedicated conduit to provide mechanical protection. 4
6 Below is a table listing the color code for the BF 9-conductor wire. Wire #1 Zone Wire #2 Zone Black Common Black Common Blue 1 Blue 9 Green 2 Green 10 Red 3 Red 11 Yellow 4 Yellow 12 Clear 5 Clear 13 Purple 6 Purple 14 White 7 White 15 Brown 8 Brown 16 A typical TM system is shown in drawing # A. Drawing # A shows one sensor for each zone. Depending on the application you may wish to use multiple sensors on each zone. The TM wire from the sensors is spliced at the instrument in the splice compartment. The 9 wires are spliced color to color using grease crimps. 5
7 TM Series Thermostat Style - Temperature Sensors TM Series sensors are available in three standard styles: 1. Bearing Probes: consisting of a stainless steel.25 diameter thermowell and hardware for mounting through 1/8 NPT threaded grease zerk hole in the bearing housing. Bearing can still be maintained with the probe in place. 2. Belt alignment sensor: consisting of a 5 x 1 half round brass friction bar, a mounting plate and sensor. Surface mount sensor: consisting of a thermostat imbedded in a plated brass mounting lug with 10 of stainless braided duplex. 3. Surface sensors have a plated copper, mounting lug with hole in it for bolting directly to a piece of equipment. These sensors are designed to be used on equipment that has no grease zerk or where access to the grease zerk is limited. TM Bearing Probes: All TM Probes are available in 1408, 1608, and 1808 standard sizes. All sensors use a single pole NC bimetallic thermostat with a contact rating of 1 amp 24 VAC or DC resistive. All probes come with mounting hardware to mount the probe into the standard 1/8 NPT grease zerk hole in the bearing housing. All probes come with a standard 10 of stainless steel overbraided splicing pigtail attached. Model TMP-140, 160 or 180 Bearing probes (Complete) Description: 140, 160 or 1808 thermostat imbedded in a 4 long by ¼ D stainless Steel thermowell, includes steel T grease zerk fitting, Brass compression connector and 10 of stainless overbraided splicing pigtail. Components available as replacement parts: 1. Probe style sensor with pigtail only. 2. Steel T grease zerk fitting with brass ¼ compression fitting. TM Belt Alignment Sensors: All TM belt alignment sensors are available in 1408, 1608, and 1808 standard sizes. All sensors use a single pole NC bimetallic thermostat with a contact rating of 1 amp 24 VAC or DC resistive. All belt alignment sensors come with brass friction bar and rub mounting plate. All belt alignment sensors come with a standard 10 of stainless steel overbraided splicing pigtail attached. Model TMR-140, 160 or 180 Belt alignment sensor (Complete) Description: 140, 160 or 1808 thermostat imbedded in a plated copper lug with a ¼ mounting hole, 5 x 1 half round brass friction bar and Teflon insulator with mounting plate. Sensors come with a standard 10 of stainless overbraided splicing pigtail attached. Components available as replacement parts: 1. Lug style surface mount sensor with pigtail only. 2. Replacement 5 x 1 half round brass friction bar. 3. Teflon spacer/insulator x 7 mounting plate. 6
8 TM Surface Mount Sensors: All TM surface mount sensors are available in 1408, 1608, and 1808 standard sizes. All sensors use a single pole NC bimetallic thermostat with a contact rating of 1 amp 24 VAC or DC resistive. All surface mount sensors come with a standard 10 of stainless steel overbraided splicing pigtail attached. These sensors are designed to be used on bearings that have small grease zerks, where probe style sensors can not be used. Model TMS-140, 160 or 180 Surface mount sensor (Complete) Description: 140, 160 or 1808 thermostat imbedded in a plated copper lug with a ¼ mounting hole. Sensors come with a standard 10 of stainless overbraided splicing pigtail attached. TMS surface sensors are also available with a large washer style lug that can accommodate being placed under the grease zerk. (NOTE: The grease zerk must compress fully against the sensor to provide good heat transfer from the bearing housing to the sensor.) It is also recommended that you reduce the temperature range of the surface sensor by 20 to 40 degrees in order to accommodate the slower transfer of heat with this type of arrangement. Other sized temperature sensors are available as special order only items. Please contact Boone Cable Works & Electronics, Inc. for price, availability, and lead-time on all special orders. 5. Standard Sensors A. Probe Sensor The probe sensor is designed to be inserted into the grease zerk hole of a bearing. (See Drawing #180090) Heat is transferred from the bearing race to the probe sensor. Below are directions for proper probe installation. 1. Clean around bearing and grease zerk to avoid getting any dirt into the bearing. 2. Remove the existing zerk. 3. Install the brass nipple, tee and 1/8 compression connector assembly. 4. Reinstall the zerk into the side of the tee. 5. Insert the stainless steel thermostat housing into the bearing into the compression connector assembly at the top of the steel mounting T. 6. Hold the stainless steel thermostat housing so that it is approximately 1/8 from the bearing race and tighten the compression connector nut. 7. Run the probe sensor wire into a splice fitting and attach the sensor into the system. 7
9 WARNING IF THE SENSOR IS NOT ATTACHED PROPERLY AND SECURELY TO THE MONITORED PIECE OF EQUIPMENT, HEAT MAY FAIL TO TRANSFER TO THE SENSOR CAUSING IT TO NOT OPERATE PROPERLY. CHECK THE SENSORS REGULARLY TO SEE IF THEY ARE ATTACHED SECURELY. B. Belt Alignment Belt alignment is accomplished by attaching the sensor to a brass heat transfer plate (See Drawing # and A for conduit ready installations). The brass pad transfers the heat of the belt rubbing against it and activates the sensor. Two style of brass plates are available, as ½ moon and an optional round disk style. The ½ moon offers a greater range of motion on the belt, while the round disk is easier to install. It is important to tighten the sensor securely for a good thermal bond. The sensor has a thermostat attached to the housing with approximately 10 feet of wire. See Drawing # A when wiring the probe into the system. WARNING IF THE SENSOR IS NOT ATTACHED SECURELY TO THE MONITORED PIECE OF EQUIPMENT, HEAT MAY FAIL TO TRANSFER TO THE SENSOR CAUSING IT TO NOT OPERATE PROPERLY. CHECK THE SENOSRS REGULARLY TO SEE IF THEY ARE ATTACHED SECURELY. 8
10 9
11 C. Surface Sensors The sensor is a surface mount device with high thermal conductivity. The sensor has a ¼ hole for mounting. This hole may be drilled to the size required. When mounting the sensor on a bearing with a zerk, remove the zerk. Place the zerk through the sensor mounting hole and reinsert the zerk (See Drawing #180090). The bearing may also be drilled and tapped. A bolt would be used to go through the sensor and into the threaded hole. Heat is transferred through the bearing housing to the sensor. It is critical that the sensor and bearing are securely compressed together, so that the bearing heat is transferred directly to the sensor with no air gap. The surface sensor has a thermostat attached to the bolting lug with approximately 10 feet of wire. See Drawing # A when wiring the sensor into the system. WARNING IF THE SENSOR IS NOT ATTACHED SECURELY TO THE MONITORED PIECE OF EQUIPMENT, HEAT MAY FAIL TO TRANSFER TO THE SENSOR CAUSING IT TO NOT APERATE PROPERLY. CHECK THE SENSORS REGULARLY TO SEE IF THEY ARE ATTACHED SECURELY. 10
12 D. Fire Detection The quantity and location of fire detection sensors for the TM Emergency Warning System are judgement calls and are best determined by the user. Some general recommendations are: 1. One determining factor on how many sensors per room is the cubic volume of air in that room. 2. Always mount the sensor(s) as high as possible in the room. Due to the fact that heat rises, the warmest place in a room is near the ceiling. 3. Mount sensors securely in place. This is to ensure that excessive heat will not cause the sensors to fall, before they activate in an alarm situation. Alarm pull stations should be located at exits or according to code requirements. The normally closed contact of the pull station is used. The pull station appears like any other sensor to the TM System. Which means if the wire is inadvertently broken, the TM System will issue an alarm. Accessories such as remote audible and visual alarms and an auto dialer are available. These accessories use the normally open or normally closed contacts on the TM Instrument. The auto dialer offers one voice/pager message up to four numbers. WARNING THE CUSTOMER IS TOTALLY RESPONSIBLE FOR SENSOR LAYOUT DESIGN. CHECK THE SENSORS REGULARLY TO SEE IF THEY ARE ATTACHED SECURELY. 11
13 6. Operation Instructions The TM Emergency Warning System Instrument has an on/off switch, test button, alarm horn and 16 monitor zone LED s respectively. To operate the system, place the on/off switch in the on position. Once the instrument is turned on, the test button activates all LED s and alarms. The monitor LED s are for each sensor or zone. They are normally off but light up for an alarm condition. The alarm buzzer supplied with the instrument is an 85 decibel buzzer that activates for an alarm condition. The alarm contacts for a remote alarm are supplied with the 110 VAC unit. They can switch a resistive load of 1A at 125 VAC. These contacts are activated in an alarm condition. When the voltage output drops below 4 volts the audible alarm is turned on, but no monitor LED s will light. This tells the operator that the batteries are low or the 110 VAC power supply needs maintenance. The battery powered unit will run a minimum of 4000 hours with no alarms and 100 hours with 1 alarm condition. To replace the batteries, remove the two screws on the splice compartment. Remove the old 9V battery from the holder and replace with a new one. The sensors are normally closed thermostats that open when the temperature goes above a preset point. The wiring to and from the thermostats is also tested in this manner. If the 9 conductor wiring is broken it will also cause an alarm on the sensor with damaged wire. TM-16 instruments are also available with an optional external alarm shutoff switch. This switch is located below the unit alarm on the left side of the instrument. (See drawing # A) Be sure to correct the problem associated to the alarm condition immediately and restore the alarm to the normal on position. All monitored equipment should be taken out of service until the alarm condition has been corrected and the alarm switch has been returned to the on position. Use the test button on the front of the instrument to confirm that the system is operating properly. 12
14 13
INSTALLATION INSTRUCTIONS FOR 9330F4552 FREE DELIVERY PLENUM KITS
RV Products Division INSTALLATION INSTRUCTIONS FOR 9330F4552 FREE DELIVERY PLENUM KITS 8330-752 CONTROL BOX KIT (12 VDC COOL ONLY) 9330C755 CONTROL BOX KIT (12 VDC HEAT READY) 8530-750 CONTROL BOX KIT
More informationINSTALLATION INSTRUCTIONS FOR 8330*5511 MOUNTING KIT
RV Products Division INSTALLATION INSTRUCTIONS FOR 8330*5511 MOUNTING KIT 8330-752 CONTROL BOX KIT (12 VDC COOL ONLY) 9330A755 CONTROL BOX KIT (12 VDC HEAT/COOL) 8530-750 CONTROL BOX KIT (24 VAC COOL ONLY)
More informationA B A B4
TM TM SERVICE INSTRUCTIONS Thermo-Aire Heater Kits and Air-Heater Assemblies 383808-A4 383808-B4 383880-A4 383880-B4 DESCRIPTION The Thermo-Aire Heater is used in situations where oils of heavier viscosity
More informationINSTALLATION INSTRUCTIONS FOR MOUNTING KIT
RV Products Division INSTALLATION INSTRUCTIONS FOR 8330-5501 MOUNTING KIT 8330-752 CONTROL BOX KIT (12 VDC COOL ONLY) 9330B755 CONTROL BOX KIT (12 VDC HEAT/COOL) 8530-750 CONTROL BOX KIT (24 VAC COOL ONLY)
More informationSpecial Provision No. 682S27 June This Special Provision refers to the following standards, specifications or publications:
CONTROLLER CABINETS, POLE MOUNTED - Item No. Special Provision No. 682S27 June 2017 1. SCOPE This Special Provision covers the requirements for the installation of pole mounted controller cabinets and
More informationINSTALLATION INSTRUCTIONS FOR 7330C740 FLUSH MOUNT CEILING ASSEMBLY
INSTALLATION INSTRUCTIONS FOR 7330C740 FLUSH MOUNT CEILING ASSEMBLY TABLE OF CONTENTS Warnings...3 Package Contents...3 General Information...3 Supply Ducting And Registers...3 Routing 115 VAC Wiring...5
More informationINSTALLATION INSTRUCTIONS FOR 7330*5511 OR 7330*5512 MOUNTING KIT 7330B751 CONTROL BOX KIT (12 VDC COOL ONLY)
INSTALLATION INSTRUCTIONS FOR 7330*5511 OR 7330*5512 MOUNTING KIT 7330B751 CONTROL BOX KIT (12 VDC COOL ONLY) 7530B750 CONTROL BOX KIT (24 VAC COOL ONLY) 8330A751 ZONE CONTROL KIT (12 VDC COOL ONLY) 8530B751
More informationINSTALLATION INSTRUCTIONS FOR 8330*633* COOL ONLY A/C 8330*635* HEAT READY A/C 8530*63** HEAT PUMP CHILLGRILLE FLUSH MOUNT CEILING ASSEMBLY
RV Products Division INSTALLATION INSTRUCTIONS FOR 8330*633* COOL ONLY A/C 8330*635* HEAT READY A/C 8530*63** HEAT PUMP CHILLGRILLE FLUSH MOUNT CEILING ASSEMBLY DESIGNED AND MANUFACTURED BY THE MAKERS
More information24 VAC SYSTEM CONTROL KIT
24 VAC SYSTEM CONTROL KIT Model: CK-91F and CK-91FG Designed for use with the SWG Series Power Venter for controlling Natural Gas or L.P. Gas draft induced appliances with a 24 VAC Gas Valve and a 30-millivolt
More informationINSTALLATION INSTRUCTIONS FOR 8330*63**, 8530*63** CHILLGRILLE FLUSH MOUNT CEILING ASSEMBLY
RV Products Division INSTALLATION INSTRUCTIONS FOR 8330*63**, 8530*63** CHILLGRILLE FLUSH MOUNT CEILING ASSEMBLY DESIGNED AND MANUFACTURED BY THE MAKERS OF COLEMAN -MACH AIR CONDITIONERS TABLE OF CONTENTS
More informationPS-3E AND PS-6E ELECTRIC CONVECTON STEAMERS PARTS AND SERVICE MANUAL
PS-3E AND PS-6E ELECTRIC CONVECTON STEAMERS PARTS AND SERVICE MANUAL EFFECTIVE AUGUST 1, 2014 Superseding All Previous Parts Lists. The Company reserves the right to make substitution in the event that
More informationWARNING. Failure to install this kit within the guidelines might adversely affect safety, performance, component life and warranty coverage.
! WARNING WARNING: This kit should be installed only by qualified service personnel to reduce the risk of electric shock, serious injury, or fire. A plumbing permit and the services of a licensed plumber
More informationFigure 1 - Steam Generator. Electrical Installation Instructions. 01/09 Pub. No. 200-A - 1 -
Electrical Installation Instructions C US Steambath Generators The Steamist TSG Generator operates with a TSC control mounted inside and optional TSR remote control located outside the steamroom. It s
More informationBUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS
BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS PLEASE READ COMPLETE INSTRUCTIONS BEFORE YOU BEGIN LEAVE INSTALLATION INSTRUCTIONS AND USER'S GUIDE WITH OWNER ALL ELECTRIC WIRING AND PLUMBING MUST BE DONE
More informationSeries. Access Power Controllers. Installation Guide
Series Access Power Controllers Installation Guide Models Include: Maxim11 - Power Supply 1: 12VDC @ 3.5 amp or 24VDC @ 2.7 amp. - Power Supply 2: 12VDC @ 3.5 amp or 24VDC @ 2.7 amp. - Sixteen (16) fuse
More informationDRAIN WATER TEMPERING INSTALL
! WARNING! CAUTION DRAIN WATER TEMPERING KIT - 0601-00-07-86 WARNING! This kit should be installed only by qualified service personnel to reduce the risk of electric shock, serious injury, or fire. A plumbing
More informationCircoloTM A Kichler Décor ceiling fan Designed to coordinate with a popular Kichler Lighting collection.
CircoloTM A Kichler Décor ceiling fan Designed to coordinate with a popular Kichler Lighting collection. Includes our new CoolTouch TM Control System Looks permanent, but goes wherever you go! U.S. Patent
More informationINSTALLATION INSTRUCTIONS John Deere One Series; 1023E, 1025R and 1026R Models A HEATER KIT. Figure 1 (General Layout and Parts I.D.
A-11978 HEATER KIT Figure 1 (General Layout and Parts I.D.) Read these instructions and identify all components. Please retain these instructions for future reference and parts ordering information. Refer
More informationTS40 Product Assembly & Service Information Manual
TS40 Product Assembly & Service Information Manual MODEL: SERIAL NUMBER(S): MANUFACTURE DATE: Please review all the information in this manual before attempting assembly and/or maintenance. ASSEMBLY FOR:
More informationWARNING DESCRIPTION PART NUMBER QTY PLUMBING, DYNATEMP DRAIN QUENCH BRACKET, THERMOSTAT DRAIN QUENCH
! WARNING WARNING: This kit should be installed only by qualified service personnel to reduce the risk of electric shock, serious injury, or fire. A plumbing permit and the services of a licensed plumber
More informationLMS-188-4P-BMS 4 POINT DIGITAL MONITOR/ALARM WITH PROTOCOL CONVERTER OPERATING INSTRUCTIONS
G LMS 188 4P BMS August, 2018 LMS-188-4P-BMS 4 POINT DIGITAL MONITOR/ALARM WITH PROTOCOL CONVERTER OPERATING INSTRUCTIONS! WARNING: This product can expose you to chemicals including lead, which is known
More informationINSTALLATION INSTRUCTIONS FOR 6636 SERIES PACKAGE AIR CONDITIONER
INSTALLATION INSTRUCTIONS FOR 6636 SERIES PACKAGE AIR CONDITIONER TABLE OF CONTENTS 1. Warnings...................................................... 3 2. Component Match-Up...........................................
More informationThermo-Platens. Cast-In Aluminum and Bronze Platen Die Heaters for Plastics Processing Equipment
Cast-In Aluminum and Bronze Platen Die Heaters for Plastics Processing Equipment Cast-In Platen Heaters are widely accepted as the industry standard for heating critical, temperaturesensitive plastics
More informationTECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:
ACORN SAFETY P.O. BOX 3527 CITY OF INDUSTRY, CA 91744-0527 UNITED STATES OF AMERICA WWW.ACORNSAFETY.COM INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS ELECTRIC ALARM WITH LIGHT AND HORN Model: S0000-AL2-C1D1-DB1
More informationINSTALLATION INSTRUCTIONS FOR 6536 SERIES TWO TON PACKAGED HEAT PUMP
INSTALLATION INSTRUCTIONS FOR 6536 SERIES TWO TON PACKAGED HEAT PUMP TABLE OF CONTENTS 1. Warnings...2 2. Component Match-Up...2 3. Unit Depiction Figures...3 4. Blower Performance Data...5 5. General
More informationINSTALLATION INSTRUCTIONS FOR SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMP
RV Products Division INSTALLATION INSTRUCTIONS FOR 46515 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMP TABLE OF CONTENTS 1. Warnings.................................................. 2 2. Component
More informationEIC SOLUTIONS, INC. Thermoelectric Air conditioner installation and operation manual. FOR 1500 Btu MODEL # S
EIC SOLUTIONS, INC. Thermoelectric Air conditioner installation and operation manual FOR 1500 Btu MODEL # S AAC-145-T-E AAC-145-4XT-E AAC-145-T-E-HC AAC-145-4XT-E-HC AAC-145-XXXXX Cooling Solutions for
More informationSAVE THESE INSTRUCTIONS
Built-In Dishwasher Dishwashers Write the model and serial numbers here: Model # Serial # You can find them on the tub wall just inside the door or. the lower part of back. Installation Instructions DDW1802W
More informationFES - Series Portable Electric Heaters. YES - Series Suspended Electric Heaters CONTENTS
FOSTORIA INDUSTRIES, INC. A DIVISION OF FES - Series Portable Electric Heaters YES - Series Suspended Electric Heaters (FES-1524-3E shown) IMPORTANT SAFETY INFORMATION INSIDE Serious injury or death possible.
More informationINSTALLATION INSTRUCTION
INSTALLATION INSTRUCTION ELECTRIC HEAT S THRU 05 5 THRU Supersedes: (9) (00) 0-5 FOR SINGLE PACKAGE CONDITIONERS THRU TON SINGLE PACKAGE HEAT PUMPS THRU 5 TON GENERAL This instruction contains all the
More information24 VAC SYSTEM CONTROL KIT Model: CK-91F and CK-91FG
24 VAC SYSTEM CONTROL KIT Model: CK-91F and CK-91FG Designed for use with the SWG Series Power Venter for controlling Natural Gas or L.P. Gas draft induced appliances with a 24 VAC Gas Valve and a 30-millivolt
More informationKimberleyTM A Kichler Décor ceiling fan Designed to coordinate with a popular Kichler Lighting collection.
KimberleyTM A Kichler Décor ceiling fan Designed to coordinate with a popular Kichler Lighting collection. Includes our new CoolTouch TM Control System Looks permanent, but goes wherever you go! U.S. Patent
More informationNext Generation Corona Discharge Installation & Operation Manual
Next Generation Corona Discharge Installation & Operation Manual 4-2319-01 Rev.A IMPORTANT SAFETY INSTRUCTIONS READ & FOLLOW ALL INSTRUCTIONS Read this manual completely before attempting installation.
More informationOrrin. Instruction Manual. Includes our new CoolTouch TM Control System Looks permanent, but goes wherever you go! U.S.
Includes our new CoolTouch TM Control System Looks permanent, but goes wherever you go! U.S. Patent Pending Orrin A Kichler Select ceiling fan Kichler Lighting 7711 East Pleasant Valley Road P.O. Box 318010
More informationValkyrieTM. Instruction Manual. Includes our new CoolTouch TM 6 Speed DC Control System Looks permanent, but goes wherever you go! U.S.
ValkyrieTM A Kichler Décor ceiling fan Designed to coordinate with a popular Kichler Lighting collection. Includes our new CoolTouch TM 6 Speed DC Control System Looks permanent, but goes wherever you
More informationInstallation Guide for models:
140 58th St. Brooklyn, NY Access Power Controllers with Power Supplies Installation Guide for models: Maximal3FD - 12VDC @ 4.6 amp or 24VDC @ 5.2 amp. - Sixteen (16) PTC protected power-limited outputs.
More informationINSTALLATION INSTRUCTIONS FOR MOUNTING KIT 7330B751 CONTROL BOX KIT (12 VDC COOL ONLY) CONTROL BOX KIT (12 VDC HEAT/COOL)
INSTALLATION INSTRUCTIONS FOR 8330-5511 MOUNTING KIT 7330B751 CONTROL BOX KIT (12 VDC COOL ONLY) 9330-755 CONTROL BOX KIT (12 VDC HEAT/COOL) 7530B750 CONTROL BOX KIT (24 VAC COOL ONLY) 9530-755 CONTROL
More informationElectric Floor Heating Cables
Electric Floor Heating Cables Danfoss LX Electric Floor Heating Cable Systems combine the highest comfort levels with the maximum energy efficiency. Our Electric Floor Heating Cable Systems offer the following
More informationTECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:
ACORN SAFETY P.O. BOX 3527 CITY OF INDUSTRY, CA 91744-0527 UNITED STATES OF AMERICA WWW.ACORNSAFETY.COM INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS ELECTRIC ALARM WITH LIGHT AND HORN Models S0000-AL1
More informationFitchTM. Instruction Manual. Includes our Basic Function CoolTouch TM Control System Looks permanent, but goes wherever you go!
Includes our Basic Function CoolTouch TM Control System Looks permanent, but goes wherever you go! FitchTM A Kichler Décor ceiling fan U.S. Patent Pending Kichler Lighting 7711 East Pleasant Valley Road
More informationCEILING FAN OWNER'S MANUAL
Style that revolves around you. CEILING FAN OWNER'S MANUAL QUATRO 10/09 WARNING: Read and follow these instructions carefully and be mindful of all warnings shown throughout. GENERAL INSTALLATION & OPERATION
More informationEIC SOLUTIONS, INC. Thermoelectric Air conditioner installation and operation manual. FOR 500 Btu MODEL # S
EIC SOLUTIONS, INC. Thermoelectric Air conditioner installation and operation manual FOR 500 Btu MODEL # S AAC-142-4XT AAC-142-4XT-HC AAC-142-4XT-XXXXX Cooling Solutions for Mission-Critical Electronics
More informationALTAIR II CONVECTION STEAM COOKER PARTS AND SERVICE MANUAL
ALTAIR II CONVECTION STEAM COOKER PARTS AND SERVICE MANUAL EFFECTIVE MAY, 0 Superseding All Previous Parts Lists. The Company reserves the right to make substitution in the event that items specified are
More informationHighland ManorTM A Kichler Décor ceiling fan Designed to coordinate with a popular Kichler Lighting collection.
Highland ManorTM A Kichler Décor ceiling fan Designed to coordinate with a popular Kichler Lighting collection. Includes our new CoolTouch TM Control System Looks permanent, but goes wherever you go! U.S.
More informationPO Box 827 Hawley, MN (218) Fax (218)
Introduction Before proceeding with the installation or operation of the Oil Alert System, read all instructions thoroughly, as well as complying with all Federal, State and Local codes, Regulations and
More informationFerronTM. Instruction Manual A Kichler Decor ceiling fan
Includes our new CoolTouch TM 6 Speed DC Control System Looks permanent, but goes wherever you go! U.S. Patent Pending 300160 A Kichler Decor ceiling fan HIGH EFFICIENCY DC MOTOR FerronTM Kichler Lighting
More informationHatteras BayTM. Patio. Instruction Manual. Includes our new CoolTouch TM Control System Looks permanent, but goes wherever you go! U.S.
Hatteras BayTM Patio A Kichler Décor ceiling fan Designed to coordinate with a popular Kichler Lighting collection. Includes our new CoolTouch TM Control System Looks permanent, but goes wherever you go!
More informationSP-1000X. Panic Device Power Controller Installation Guide. Rev
TM SP-1000X Panic Device Power Controller Installation Guide Rev. 120213 Overview: SP-1000X will operate up to two (2) 24VDC panic hardware devices simultaneously. It is designed to handle the high current
More informationINSTALLATION INSTRUCTIONS FOR 6532 SERIES PACKAGE HEAT PUMP
INSTALLATION INSTRUCTIONS FOR 6532 SERIES PACKAGE HEAT PUMP RV Products A Division of Airxcel, Inc. P.O. Box 4020 Wichita, KS 67204 1976-360 (1-02) PP TABLE OF CONTENTS 1. Warnings......................................................
More informationIMPORTANT INSTRUCTIONS READ & SAVE
10,000W/240V WALL / CEILING MOUNTED GARAGE HEATER OWNER S MANUAL IMPORTANT INSTRUCTIONS READ & SAVE Model No.: DR-910F 10,000W 240V 60Hz 1 TABLE OF CONTENTS Important Instructions.3 Installing Instructions.
More informationViking Installation Guide
Viking Installation Guide Viking Range Corporation 111 Front Street Greenwood, Mississippi 38930 USA (662) 455-1200 For product information, call 1-888-VIKING1 (845-4641) or visit the Viking Web site at
More informationChicagoTM. Instruction Manual. Includes our new CoolTouch TM Control System Looks permanent, but goes wherever you go! U.S.
Includes our new CoolTouch TM Control System Looks permanent, but goes wherever you go! U.S. Patent Pending ChicagoTM A Kichler Decor ceiling fan Kichler Lighting 7711 East Pleasant Valley Road P.O. Box
More informationTECHNICAL INFORMATION Touchtronic Clothes Dryers
TECHNICAL INFORMATION Touchtronic Clothes Dryers Includes: T1302, T1303, T1322, T1329ci T1403 & T1405 2004 Miele This page intentionally left blank. Table of Contents GENERAL INFORMATION A. Warning and
More informationINSTALLATION INSTRUCTIONS FOR 7370A736 FLUSH MOUNT CEILING PLENUM
INSTALLATION INSTRUCTIONS FOR 7370A736 FLUSH MOUNT CEILING PLENUM TABLE OF CONTENTS Warnings...2 Package Contents...2 General Information...3 Ceiling Plenum Installation Requirement...3 Supply Ducting
More informationML-82 Parts Manual. Phase 7 Microprocessor with F.S.S. Options
ML-82 Parts Manual Phase 7 Microprocessor with F.S.S. Options American Dryer Corporation 88 Currant Road Fall River, MA 02720-4781 Telephone: (508) 678-9000 / Fax: (508) 678-9447 E-mail: techsupport@amdry.com
More informationTURBO Fiberglass Cone Fan and Grill Fan 48'' Belt Drive. Installation & Operator s Instruction Manual
TURBO Fiberglass Cone Fan and Grill Fan 48'' Belt Drive Installation & Operator s Instruction Manual July 1998 MV1383B Chore-Time TURBO TM Fan Extended Warranty Chore-Time Equipment warrants new TURBO
More informationInnes. Instruction Manual A Kichler Decor ceiling fan. Includes our new TM
Innes 300130 A Kichler Decor ceiling fan Includes our new CoolTouch Control System Looks permanent, but goes wherever you go! U.S. Patent Pending Kichler Lighting 7711 East Pleasant Valley Road P.O. Box
More informationInstalling the Cisco ONS FAP-4 Fuse Alarm Panel
Installing the Cisco ONS 15454-FAP-4 Fuse Alarm Panel Product Number: 15454-FAP-4= This document explains how to install, test, operate, and maintain the Cisco ONS 15454-FAP-4 fuse alarm panel. This document
More informationELECTRIC INSTANTANEOUS WATER HEATER INSTALLATION GUIDE AND OWNERS MANUAL THERMOSTATIC
ELECTRIC INSTANTANEOUS WATER HEATER INSTALLATION GUIDE AND OWNERS MANUAL THERMOSTATIC MODELS COVERED: EFT-5500-4-S-10 240V EFT-6500-4-S-10 240V EFT-7500-4-S-10 240V EFT-9500-4-S-10 240V EFT-8300-2-S-10
More information24 VAC SYSTEM CONTROL KIT
24 VAC SYSTEM CONTROL KIT Model: CK-92F and CK-92FG Designed for use with the SWG Series Power Venter for controlling Natural Gas or L.P. Gas appliances with a 24 VAC Gas Valve and a 30-millivolt controlled
More information60" Hatteras BayTM. Patio. Instruction Manual. Includes our new Wall Control System. A Kichler Décor ceiling fan
Includes our new Wall Control System 60" Hatteras BayTM Patio A Kichler Décor ceiling fan Kichler Lighting 7711 East Pleasant Valley Road P.O. Box 318010 Cleveland, Ohio 44131-8010 Customer Service 866.558.5706
More informationSTEAMPRO. Steam Generator Troubleshooting and Service Guide
STEAMPRO Steam Generator Troubleshooting and Service Guide TABLE OF CONTENTS Page PREFACE... 1 I. STEAMPRO STEAM GENERATOR SYSTEM...2 II. PLUMBING AND ELECTRICAL...3-4 III. SYSTEM OVERVIEW... 5-10 IV.
More informationINSTALLATION INSTRUCTIONS FOR 6797A737 HEAT PUMP FLUSH MOUNT CEILING PLENUM
INSTALLATION INSTRUCTIONS FOR 6797A737 HEAT PUMP FLUSH MOUNT CEILING PLENUM TABLE OF CONTENTS Warnings............................................................................... 2 Package Contents........................................................................
More informationMEIKO Undercounter Dish and Glass Washing Machine. Spare Parts List 208V/230V 1/3-PHASE 60 HZ
MEIKO Undercounter Dish and Glass Washing Machine Spare Parts List FV40.G 08V/0V /-PHASE 60 HZ Rev.. Updated: 0-8-04 CONTENTS. WASH PUMP PAGE. WASH SYSTEM PAGE. BOOSTER PUMP PAGE 7. SOLENOID / FILL VALVE
More informationLaceyTM. Instruction Manual. Includes our new CoolTouch TM 6 Speed DC Control System Looks permanent, but goes wherever you go! U.S.
LaceyTM A Kichler Décor ceiling fan Designed to coordinate with a popular Kichler Lighting collection. Includes our new CoolTouch TM 6 Speed DC Control System Looks permanent, but goes wherever you go!
More informationECOJET EJ-10E & EJ-7E ELECTRIC CONVECTION STEAMER W/TWIN GENERATORS PARTS AND SERVICE MANUAL
ECOJET EJ-10E & EJ-7E ELECTRIC CONVECTION STEAMER W/TWIN GENERATORS PARTS AND SERVICE MANUAL EFFECTIVE JULY 31, 2014 Superseding All Previous Parts Lists. The Company reserves the right to make substitution
More informationInstallation Guide for models:
140 58th St. Brooklyn, NY Access Power Controllers with Power Supplies Installation Guide for models: Maximal11F - Power Supply 1: 12VDC @ 3.3 amp or 24VDC @ 3.6 amp. - Power Supply 2: 12VDC @ 3.3 amp
More informationKE-Series Constant-Wattage Heating Cable
KE-Series Constant-Wattage Heating Cable Installation Instructions Read and understand this material before installing this heater. Failure to understand how to safely install the heater could result in
More informationInstallation Instructions
50ZPB, C, 50ZHB, C, PA3Z ---A, PH3Z ---A, PA4Z, PH4Z, PAJ4,PHJ4,WJA4,WJH4 SMALL PACKAGED PRODUCTS (SPP) Accessory Electric Heaters 5---20 kw For 14 SEER, R---410A Manufactured Home Installation Instructions
More informationInstallation Instructions. For the 18 Built-In Dishwasher and Front Color Panels
Installation Instructions For the 18 Built-In Dishwasher and Front Color Panels Printed in USA 154232102 Before You Begin DO NOT INSTALL DISHWASHER UNTIL YOU HAVE READ ALL INSTRUCTIONS. FOR YOUR SAFETY,
More informationService. Manual. Trash Compactor. Preferred Service FCU150
Service Preferred Service Manual Trash Compactor This Base Manual covers general and specific information including, but not limited to the following models: FCU150 SMK-0004 FEB 2012 2 Table of Contents
More informationUHIR Series. Horizontal or Vertical Mounting Industrial / Commercial Electric Unit Heater. Owner s Manual
UHIR Series Horizontal or Vertical Mounting Industrial / Commercial Electric Unit Heater Owner s Manual This manual covers installation, maintenance and repair parts. Read carefully before attempting to
More informationTO-SK-1 Tip-Over Switch Kit For FSP-43 AND FSP-95
TPI Corporation P.O. BOX 4973 JOHNSON CITY, TN 37602 www.tpicorp.com TO-SK-1 Tip-Over Switch Kit For FSP-43 AND FSP-95 REFER TO COMPLETE INDEX OF INFORMATION ON PAGE 2 INDEX General Description & Use Page
More informationCentro-Matic Automated Lubrication Systems System Controls
Selecting the right controls for your automated lubrication system is one of the last steps in the design process. Several different models may be chosen to control power-operated pumps, depending on the
More informationSAFETY AND INSTALLATION MANUAL MODEL 8100
SAFETY AND INSTALLATION MANUAL ENERGY RECOVERY VENTILATORS MODEL 8100 Provides year-round fresh air Recovers 77% of the apparent heating or cooling energy from the exhausted air See Warnings Page 3 Table
More informationPARTS & ACCESSORIES INSTALLATION AND SAFETY INSTRCUTIONS ITEM NO.:60010BZGTGLD SAFETY PRECAUTION. Canopy. Downrod. Housing. Transmitter CR2032/3V
L I G H T I N G INSTALLATION AND SAFETY INSTRCUTIONS ITEM NO.:000BZGTGLD SAFETY PRECAUTION PARTS & ACCESSORIES Canopy Downrod Housing WARNING To make sure power is off before attempting installation. WARNING
More informationC Electrical Connection Kit
1548-4010C Electrical Connection Kit For Use With Dekoron 2700 and 2300 Family of Heating Cables Installation Instructions Kit Description The Dekoron 1548-4010C electrical connection and end seal kit
More information60" Lyndon Patio. Instruction Manual Customer Service :30 AM to 5:00 PM EST, Monday - Friday A Kichler Decor ceiling fan
60" Lyndon Patio TM 310140 A Kichler Decor ceiling fan Includes wall mount control system Kichler Lighting 7711 East Pleasant Valley Road P.O. Box 318010 Cleveland, Ohio 44131-8010 Instruction Manual Customer
More informationSECTION PANELBOARDS Painting Wire and Cable Overcurrent Protective Devices.
SECTION 16470 PANELBOARDS PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 09900 - Painting. 2. 16120 - Wire and Cable. 3. 16475 - Overcurrent Protective Devices. 1.02 SYSTEM DESCRIPTION A. Performance
More informationML-758 Parts Manual. Phase 7 / Non-Coin / Dual Timer with F.S.S. Options
ML-758 Parts Manual Phase 7 / Non-Coin / Dual Timer with F.S.S. Options American Dryer Corporation 88 Currant Road Fall River, MA 02720-4781 Telephone: (508) 678-9000 / Fax: (508) 678-9447 E-mail: techsupport@amdry.com
More informationJBS-100-ECP-A COMBINATION POWER CONNECTION BOX AND DIGITAL ELECTRONIC CONTROLLER INSTALLATION INSTRUCTIONS
JBS-100-ECP-A COMBINATION POWER CONNECTION BOX AND DIGITAL ELECTRONIC CONTROLLER INSTALLATION INSTRUCTIONS JBS-100-ECP-A with Pyrotenax MI heating cable using required MI cable grounding kit JBS-100-ECP-A
More informationFCT-CE SERIES ELECTRIC TILTING KETTLE W/HAND CRANK PARTS AND SERVICE MANUAL
FCT-CE SERIES ELECTRIC TILTING KETTLE W/HAND CRANK PARTS AND SERVICE MANUAL EFFECTIVE SEPTEMBER 12, 2014 Superseding All Previous Parts Lists. The Company reserves the right to make substitution in the
More informationTraceTek Sensing Module Installation, Operation and Maintenance Instructions DESCRIPTION SPECIFICATIONS APPROVALS TYPE NM
TTC-1 TraceTek Sensing Module Installation, Operation and Maintenance Instructions DESCRIPTION The nvent RAYCHEM TraceTek TTC-1 sensing module is used with TraceTek sensing cables to detect liquid leaks.
More informationSprite III Warewash Dispensing System
Sprite III Warewash Dispensing System Reference Manual DM-700 Series Online and downloadable Product Manuals and Quick Start Guides are available at www.hydrosystemsco.com Please check online for the latest
More information54" Skye. Instruction Manual Customer Service :30 AM to 5:00 PM EST, Monday - Friday A Kichler Decor ceiling fan
54" Skye TM 300167 A Kichler Decor ceiling fan Includes wall mount control system Kichler Lighting 7711 East Pleasant Valley Road P.O. Box 318010 Cleveland, Ohio 44131-8010 Instruction Manual Customer
More information3500 SERIES CONVECTION STEAM COOKER PARTS AND SERVICE MANUAL
3500 SERIES CONVECTION STEAM COOKER PARTS AND SERVICE MANUAL EFFECTIVE JULY 30, 2014 Superseding All Previous Parts Lists. The Company reserves the right to make substitution in the event that items specified
More informationOPERATING AND MAINTENANCE MANUAL FOR ELECTRIC STAINLESS STEEL HEATER FOR DEIONIZED (DI) WATER ELECTRIC HEATER COMPANY BASE MODEL D
OPERATING AND MAINTENANCE MANUAL FOR ELECTRIC STAINLESS STEEL HEATER FOR DEIONIZED (DI) WATER ELECTRIC HEATER COMPANY BASE MODEL D HUBBELL ELECTRIC HEATER COMPANY P.O. BOX 288 STRATFORD, CT 06615 PHONE:
More informationINSTALLATION INSTRUCTIONS AND OWNER S MANUAL
INSTALLATION INSTRUCTIONS AND OWNER S MANUAL ELECTRIC INSTANTANEOUS WATER HEATERS WITH PhD 208 and 480 VAC three phase 32 144 kw 600 VAC three phase 130 / 150 kw BEFORE ATTEMPTING ANY INSTALLATION OR SERVICE
More informationInstallation Manual PS-225 & PS-275
Installation Manual PS-225 & PS-275 Table of Contents Pre-Uncrating Checklist... 1 Verifying System Requirements... 2 Verifying System Direction... 2 Verifying the Electrical Requirements... 2 Removal
More informationInstallation Instructions
Electric Heaters 5 --- 20 kw SMALL PACKAGED PRODUCTS (SPP) Accessory Electric Heaters For 13 SEER, R---410A Manufactured Home Installation Instructions NOTE: The Dual Point Kit can only be installed on
More information! WARNING. Before using product, read and understand instructions.
McDonnell & Miller Installation & Maintenance Instructions MM-273A Manual eset Applications: Conductance type control for steam boilers when a manual reset high water alarm or cut-off is required. 5-1/2"
More informationINSTALLATION INSTRUCTIONS
Harwil Model Q-16 fluid flow switch is intended for use in flow lines with fluids not harmful to brass, stainless steel, and EPDM. The switch is used to signal, start, or stop electrically operated equipment
More informationSPRITE Warewash Dispensing System
SPRITE Warewash Dispensing System Reference Manual DM-400 NUMERIC Series Online and downloadable Product Manuals and Quick Start Guides are available at www.hydrosystemsco.com Please check online for the
More informationINSTALLATION INSTRUCTION for ceiling fan
INSTALLATION INSTRUCTION for ceiling fan F8203 Installation & Operating Instructions for the Parrotuncle Owner s Installation,Manual Motor is core parts of the fan and the most expensive in all the components.
More information#ADENCE4- $ESIGNED )NCLUDES #OOL4OUCH4- +ICHLER )NSTRUCTION #USTOMER KHA
KHA9090108 1 1. SAFETY RULES 1. To reduce the risk of electric shock, insure electricity has been turned off at the circuit breaker or fuse box before beginning. 2. All wiring must be in accordance with
More informationOPERATOR S MODEL CW-216 CW-114 DISPLAY COUNTER WARMER REGISTER WARRANTY ONLINE AT
OPERATOR S M A N U A L DISPLAY COUNTER WARMER MODEL CW-216 CW-114 REGISTER WARRANTY ONLINE AT WWW.HENNYPENNY.COM TABLE OF CONTENTS Section Page Section 1. INTRODUCTION... 1-1 1-1. Display Counter Warmer...
More information12.0 cu.ft., 2 way, 4-door, R.V. refrigerator with ice maker.
Installation Manual For 1200ACXX models: For 120XAC-IMXX models: 12.0 cu.ft., 2-way, 4-door, R.V. refrigerator. 12.0 cu.ft., 2 way, 4-door, R.V. refrigerator with ice maker. The letter X, in the model
More information30-YEAR LIMITED WARRANTY
PROGRESS LIGHTING 30-YEAR LIMITED WARRANTY PROGRESS LIGHTING FAN MOTORS ARE WARRANTED TO THE END USER TO BE FREE OF ELECTRICAL AND/OR MECHANICAL DEFECTS FOR A PERIOD OF 30 (THIRTY) YEARS FROM DATE OF SALE.
More informationElectrical Installation Instructions
Steambath Generators Models: SM-2 and SM-5! Electrical Installation Instructions C US LISTED 995C WARNING: Elderly persons, pregnant women, or those suffering from heart disease, high blood pressure, diabetes,
More informationChromalox. Installation, Operation. Screw Plug Heating Solution Control Panel Assembly for Screw Plug Heaters RENEWAL PARTS IDENTIFICATION
Chromalox Installation, Operation and RENEWAL PARTS IDENTIFICATION DIVISION SALES REFERENCE DATE 4 (Supersedes PG422-) DECEMBER, 2000 SECTION RAD PE440 6-058074-002 Screw Plug Heating Solution Control
More information