CHALLENGE OF THE NEW OPTICAL FIBRE TECHNOLOGIES

Size: px
Start display at page:

Download "CHALLENGE OF THE NEW OPTICAL FIBRE TECHNOLOGIES"

Transcription

1 THE CHALLENGE OF THE NEW OPTICAL FIBRE TECHNOLOGIES 17th September 2002 Botanical Gardens Birmingham The Way We Were 1GbE and 10GbE OF Categories Channel Design Cleaning SFF Connecting Hardware Testing FIA Support Documentation 2002 Fibreoptic Industry Association

2 The Challenge the New Optical Fibre Technologies PO Box MT65, LEEDS, LS17 8YD, United Kingdom Tel: +44 (0) Fax: +44 (0) Mike Gilmore, Senior Partner Secretary: ISO/IEC JTC1 SC25 WG3: Generic Cabling Member: ISO/IEC JTC1 SC25 Project Team: SOHO Convenor ( ): CENELEC TC215 WG1: IT Cabling Chairman: BSI TCT7/-/1: IT Cabling Chairman: BSI TCT7/-/3: IT Cabling Support Group Technical and Standards Director, Fibreoptic Industry Association 2002 Limited

3 The Way We Were Attenuation coefficient (dbkm -1 ) Wavelength (nm) Mbs / Network name 850 nm MMF ISO/IEC : 10BASE-FL/FB ISO/IEC TR : 4 & 16 Mb/s Token Ring 1300 nm MMF ISO/IEC : DI PMD ISO/IEC : 100BASE-FX 62.5/125 OPB L max (db) (m) /125 OPB L max (db) (m) /125 seems to fer an advantage 2002 Limited

4 1 GbE Technologies Attenuation coefficient (dbkm -1 ) Wavelength (nm) 850nm 1300nm 1310nm 62.5/125 50/ /125 50/125 SMF OFL Modal Bandwidth (MHz.km) Assumed OF attenuation (dbkm -1 ) BASE -SX -LX 830nm 1270nm 1270nm Maximum channel length (m) Max. OF cable attenuation (db) Connecting hardware allowance (db) Maximum Channel Insertion Loss (db) Limited

5 10 GbE Technologies Attenuation coefficient (dbkm -1 ) Wavelength (nm) 850nm 1300nm 1310nm 62.5/125 50/125 MMF SMF OFL Modal Bandwidth (MHz.km) Assumed OF attenuation (dbkm -1 ) GBASE -SR/SW -LX4 -LR/LW -LX4 -ER/EW 830nm nm 1356 nm 1356 nm 1550nm Maximum channel length (m) Max. OF cable attenuation (db) Connecting hardware allowance (db) Maximum Channel Insertion Loss (db) nm Limited

6 Optical Fibre Cable Categories IT CABLING STANDARDS ISO/IEC Ed. 2 (2002) (to be published Q3, 2002) EN Ed. 2 (2002) (to be published Q3, 2002) Attenuation coefficient (max) Modal bandwidth OFL (MHz.km min) Modal bandwidth LL (MHz.km min) Propagation delay (ns.m -1 max) Wavelength 850nm 1300nm 850nm 1300nm 850nm 1300nm 850nm 1300nm Multimode OF 50/125 or 62.5/125 50/125 Singlemode OF OM1 OM2 OM3 Wavelength OS1 3,5 dbkm nm 1,0 1,5 dbkm nm 1, nm 1550nm 5 Legacy OF Legacy OF 2002 Limited

7 OM3 and 10GBASE-SR/SW 62.5/125 50/125 50/ nm OM1 OM2 OFL Modal Bandwidth (MHz.km) Assumed OF attenuation (dbkm -1 ) GBASE -SR/SW 830nm Maximum channel length (m) Max. OF cable attenuation (db) Connecting hardware allowance (db) Maximum Channel Insertion Loss (db) OM Limited

8 Mission-Critical Infrastructures BD BD BD BD BD BD CD CD BD BD 2002 Limited

9 Component Length Equivalence MMF COMPONENT EQUIVALENCE SMF COMPONENT nm Cable 3.5 dbkm dbkm -1 Cable 1.0 dbkm dbkm -1 Connector 0.75 db 0.75 db 214 m 500 m Connector 0.75 db 0.75 db 750 m 1500 m Splice 0.30 db 0.30 db 86 m 200 m Splice 0.30 db 0.30 db 300 m 600 m 2002 Limited

10 Creative Diversity Splice panel Splice panel Riser 3 Riser 1 Riser Limited

11 Cleaning Connector end-face Epoxy adhesive Contamination radius r 1 Contamination radius r 2 Core Cladding nm µm MMF 3.5 Loss (db) Total contamination radius (microns) 2002 Limited

12 Testing ARENA REFERENCE IEC IEC EN TITLE Fibre optic communication subsystem basic test procedures - Part 4-1: Fibre optic cable plant - Multimode fibre optic cable plant attenuation Fibre optic communication subsystem basic test procedures - Part 4-2: Fibre optic cable plant - Single-mode fibre optic cable plant attenuation Information Technology - Testing installed cabling TIA/EIA A TIA/EIA OFSTP-14A Optical Power Loss Measurement Installed Multimode Fiber Cable Plant (ANSI/TIA/EIA A-98) OFSTP-7 Measurement Optical Power Loss Installed Single-Mode Fiber Cable Plant (ANSI/TIA/EIA ) LSPM = Light Source - Power Meter Light Source Power Meter LASER LED Stable output Detector Connector independent cabling under test Connector dependent on cabling under test interchangeable 2002 Limited

13 Duplex and Duplex-able SFF Connectors OptiJack MT-RJ Volition (3M) - SG LC (Lucent) 2002 Limited

14 Test Equipment Grade 1 simplex single wavelength Light source λ 1 Power meter Component- based Grade 2 simplex dual wavelength Light source λ 1 λ 2 λ 1 /λ 2 Power meter Component- based Grade 3 simplex auto dual wavelength Light source λ 1 /λ 2 Power meter System-based Grade 4 duplex dual wavelength Light source Power meter λ 1 λ 2 Power meter Light source System-based Grade 5 duplex auto dual wavelength Light source Power meter λ 1 /λ 2 λ 1 /λ 2 Power meter Light source System-based Includes single location Grade Limited

15 FIA Technical Support Documents TSD TSD TSD TSD DESIGN OPTICAL FIBRE CABLING: LAN APPLICATION SUPPORT GUIDE OPTICAL FIBRE CABLING: DARK FIBRE SUPPORT GUIDE OPERATION POLARITY MAINTENANCE INSTALLATION TESTING OF INSTALLED CABLING: ATTENUATION USING LSPM EQUIPMENT TESTING OF INSTALLED CABLING: ATTENUATION USING OTDR EQUIPMENT SAFETY OPTICAL POWER: SAFETY LEVELS OPTICAL FIBRE: HANDLING OF PROCESSING CHEMICALS OPTICAL FIBRE: DISPOSAL OF WASTE MODELLING TOOLS CABLING STRUCTURES COST MODEL 2002 Limited

16 Thank you for your time 2002 Limited

STAND OUT FROM THE CROWD. Bisham Abbey, 14th May 2002 INTRODUCTION. Work Smart FIA. The Fibreoptic Industry Association STAND OUT FROM THE CROWD

STAND OUT FROM THE CROWD. Bisham Abbey, 14th May 2002 INTRODUCTION. Work Smart FIA. The Fibreoptic Industry Association STAND OUT FROM THE CROWD INTRODUCTION Work Smart FIA STAND OUT FROM THE CROWD 14th May 2002, Bisham Abbey Mike Gilmore 2002 Fibreoptic Industry Association Work Smart www.it-cabling.com www.e-readybuilding.com PO Box MT65, LEEDS,

More information

MT-RJ Optical Fiber System Field Testing

MT-RJ Optical Fiber System Field Testing MT-RJ Optical Fiber System Field Testing Table of Contents INTRODUCTION... 3 TEST JUMPERS... 4 LAUNCH CONDITIONS... 4 MT-RJ TEST KITS... 5 MT-RJ SYSTEM TESTING: Fixed transmit and receive (SC or ST-style)

More information

e-ready Building Next Generation IT infrastructures ϕ The Cabling Partnership AGENDA Opening Remarks Introduction to Installation Standards

e-ready Building Next Generation IT infrastructures ϕ The Cabling Partnership AGENDA Opening Remarks Introduction to Installation Standards The BS 6701:2004 Telecommunications equipment and telecommunications cabling - Specification for installation, operation and maintenance - THE ONE-STOP-SHOP INSTALLATION STANDARD 2004 The The Mike Gilmore

More information

This is a preview - click here to buy the full publication

This is a preview - click here to buy the full publication ISO/IEC 14763-3 CONSOLIDATED VERSION Edition 2.1 2018-08 colour inside Information technology Implementation and operation of customer premises cabling Part 3: Testing of optical fibre cabling INTERNATIONAL

More information

Data sheet OpDAT breakout cable 12x1 OM4 - bend insensitive, class Dca s1 d1 a1

Data sheet OpDAT breakout cable 12x1 OM4 - bend insensitive, class Dca s1 d1 a1 Page 1/9 Illustrations Principle diagram See enlarged drawings at the end of document Product specification connection cable I-V(ZN)HH breakout cable for direct connector termination for indoors and outdoors

More information

VTI Services Technical Bulletin (TB) OTDR Measurement of Installed Optical Fibre Cabling Permanent Links and Links

VTI Services Technical Bulletin (TB) OTDR Measurement of Installed Optical Fibre Cabling Permanent Links and Links VTI Services Technical Bulletin (TB) OTDR Measurement of Installed Optical Fibre Cabling Permanent Links and Links TB Number 004 This bulletin is supplied for information only and is intended to provide

More information

AS/NZS ISO/IEC :2012

AS/NZS ISO/IEC :2012 AS/NZS ISO/IEC 14763.3:2012 (ISO/IEC 14763-3:2011, MOD) Australian/New Zealand Standard Telecommunications installations Implementation and operation of customer premises cabling Part 3: Testing of optical

More information

infrastructure for 10, 40 and 100Gbits/s readiness

infrastructure for 10, 40 and 100Gbits/s readiness Field Testing of fiber optic infrastructure for 10, 40 and 100Gbits/s readiness Christian Schillab Product Manager Media Test Fluke Networks Europe Member BritishStandards Institute Working Group TCT 7/

More information

Link loss measurement uncertainties: OTDR vs. light source power meter By EXFO s Systems Engineering and Research Team

Link loss measurement uncertainties: OTDR vs. light source power meter By EXFO s Systems Engineering and Research Team Link loss measurement uncertainties: OTDR vs. light source power meter By EXFO s Systems Engineering and Research Team INTRODUCTION The OTDR is a very efficient tool for characterizing the elements on

More information

Industrial Fiber Optic Cables, LSZH Corrugated Armored Cable, Fibers

Industrial Fiber Optic Cables, LSZH Corrugated Armored Cable, Fibers Features and Benefits Corrugated armor Mechanical protection Low-smoke/zero-halogen (LSZH ) sheath Key life-safety benefit Meets cyclic impact and chemical resistance test Superior performance Tray-rated

More information

Data sheet OpDAT mini breakout cable 24x1 OM4 - bend insensitive

Data sheet OpDAT mini breakout cable 24x1 OM4 - bend insensitive Page 1/8 Illustrations Principle diagram See enlarged drawings at the end of document Product specification mini-breakout installation cable U-VQ(ZN)H laser-optimized, bend insensitive fiber UV-resistant,

More information

Multipurpose Cables (indoor/outdoor), Multipurpose central tube cable (maxibundle) with glass yarn armouring A-DQ(BN)H 4-24

Multipurpose Cables (indoor/outdoor), Multipurpose central tube cable (maxibundle) with glass yarn armouring A-DQ(BN)H 4-24 Features and Benefits Laminated swelling glass yarns Improved rodent resistance and longitudinal water protection UV and microbe resistant Can be directly buried or installed in ducts Metal-free cable

More information

FiberExpress Solutions

FiberExpress Solutions 7.2.1-A 7.2.1-B 7.2.1-C 7.2.1-D Simplex Patch Cord Duplex Patch Cord Hybrid Patch Cord Single-ended (pigtails) AX200057 Patch Cord Multimode SC Duplex DESCRIPTION FiberExpress Simplex and Duplex Patch

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD ISO/IEC 14763-3 First edition 2006-06 Information technology Implementation and operation of customer premises cabling Part 3: Testing of optical fibre cabling Reference number ISO/IEC

More information

Data sheet OpDAT universal cable 1x24 OM4 - bend insensitive

Data sheet OpDAT universal cable 1x24 OM4 - bend insensitive Illustrations Principle diagram Page 1/7 Product specification installation cable U-DQ(ZN)BH universal fiber optic cable for indoors/outdoors with central or stranded loose tube bend insensitive fiber

More information

TELECOMMUNICATIONS CABLING INFRASTRUCTURES - Installation Practice, Inspection and Acceptance

TELECOMMUNICATIONS CABLING INFRASTRUCTURES - Installation Practice, Inspection and Acceptance TELECOMMUNICATIONS CABLING INFRASTRUCTURES - Installation Practice, Inspection and Acceptance Mike Gilmore Standards Activities Member: ISO/IEC JTC1 SC25 WG3: Generic Cabling ISO/IEC JTC1 SC25 Project

More information

Firetuf OFC-UT-CST Fire resistant Armoured Central Tube Cable, variant in red

Firetuf OFC-UT-CST Fire resistant Armoured Central Tube Cable, variant in red Indoor/Outdoor steel tape armoured (CST) double LSHF-FR sheathed optical cable with 2 24 fibres. VDE: A/I-DQ(ZN)H(SR)H 3rd party verification of the fire tests by BUREAU VERITAS December 2014 OFC-UT-CST

More information

Fibre (TIA) Field Test Specification

Fibre (TIA) Field Test Specification This document has been prepared to aid consultants or engineers in developing contractual specifications covering the testing of duplex fibre optic cabling installations. It is offered as a general guide.

More information

A. General: Horizontal and backbone cabling shall be verified in accordance with ANSI/TIA/EIA-568-C and the addendum for fiber optic testing.

A. General: Horizontal and backbone cabling shall be verified in accordance with ANSI/TIA/EIA-568-C and the addendum for fiber optic testing. 3.4 TESTING OF FIBER OPTICS CABLING A. General: Horizontal and backbone cabling shall be verified in accordance with ANSI/TIA/EIA-568-C and the addendum for fiber optic testing. B. General: In the event

More information

Fiber Tes)ng 101 Essen)als Every Network Analyst Needs to Know. David S(llwell BCNET Oscar Rondon BCNET Gwenn Amice - EXFO

Fiber Tes)ng 101 Essen)als Every Network Analyst Needs to Know. David S(llwell BCNET Oscar Rondon BCNET Gwenn Amice - EXFO Fiber Tes)ng 101 Essen)als Every Network Analyst Needs to Know David S(llwell BCNET Oscar Rondon BCNET Gwenn Amice - EXFO Workshop format The Workshop is going to start with three short lecture style power

More information

GOF Indoor and Outdoor Cables. Documentation VWL Version 1.1 Source Code M

GOF Indoor and Outdoor Cables. Documentation VWL Version 1.1 Source Code M GOF Indoor and Outdoor Cables Documentation VWL 064.503 Version 1.1 Source Code M GOF Installation Cables Cable matrix / overview Source code M Use Indoor In- / Outdoor Outdoor Type of cable Breakout Mini-

More information

outdoor and indoor campus backbone, building backbone (riser) FDDI, Gigabit Ethernet and ATM Easy to install direct burial halogen-free

outdoor and indoor campus backbone, building backbone (riser) FDDI, Gigabit Ethernet and ATM Easy to install direct burial halogen-free GUSN Central Loose Tube Cables (Distribution) Universal Indoor/ Outdoor A/I-DQ(ZN)BH Standard Rodent Protection 05-04-8 v0.0 Ordering Information Belden Part Numbers Fibre Description / count 4 6 8 6 4

More information

GOF Indoor and Outdoor Cables. Documentation VWL Version 2.2 Source Code R

GOF Indoor and Outdoor Cables. Documentation VWL Version 2.2 Source Code R GOF Indoor and Outdoor Cables Documentation VWL 064.504 Version 2.2 Source Code R GOF Installation Cables Cable matrix / overview Source code: R Use Indoor In- / Outdoor Outdoor Type of cable Breakout

More information

Basic Professional Fiber Optic Installation

Basic Professional Fiber Optic Installation Basic Professional Fiber Optic Installation QUICK SUMMARY Length: 32 hours; or 40 hours with Fiber Optic Association CFOT certification Hands-on Activities: 40 activities, 70-75 % Text/Field Reference:

More information

Sumitomo Fiber Specification SE-9** Non-Zero Dispersion Shifted (NZDF) Zero Water Peak Large Effective Area Single Mode Fiber

Sumitomo Fiber Specification SE-9** Non-Zero Dispersion Shifted (NZDF) Zero Water Peak Large Effective Area Single Mode Fiber Sumitomo Fiber Specification SE-9** Non-Zero Dispersion Shifted (NZDF) Zero Water Peak Large Effective Area Single Mode Fiber PureGuide -LA SM Optical Fiber, TIA Type IVd ITU G.655 C and D Compliant Issued:

More information

Fibre Specification Standards

Fibre Specification Standards Fibre Specification Standards User Manual The most important thing we build is trust Cobham Wireless - Coverage Table of Contents 1. Single-mode Fibre to ITU-T Recommendation G.652 3 2. SC/APC Mated Pair

More information

4120 Fire Alarm Network Reference

4120 Fire Alarm Network Reference 4120 Fire Alarm Network Reference Features Autocall 4120 Fire Alarm Network communications are available for wired or fiber optic connections Wired communications are available on Network Interface Cards

More information

Ensuring Cabling Performance in the Customer-Owned Outside Plant. Keith Foord Product Manager Greenlee Communications

Ensuring Cabling Performance in the Customer-Owned Outside Plant. Keith Foord Product Manager Greenlee Communications Ensuring Cabling Performance in the Customer-Owned Outside Plant Keith Foord Product Manager Greenlee Communications Introduction: Outside plant fiber networks require low reflectance terminations for

More information

M310 Data Center OTDR

M310 Data Center OTDR Designed for Data Center Testing, Troubleshooting and Documentation Features Event Dead Zone 0.8 m Attenuation Dead Zone

More information

OLTS vs OTDR Tier-2 Expert; How far from Tier-1?

OLTS vs OTDR Tier-2 Expert; How far from Tier-1? OLTS vs OTDR Tier-2 Expert; How far from Tier-1? Christian Till, Application Engineer 2016/12/09 1 Why this industry is exciting! Bandwidth grows like crazy Global DC traffic 5ZB now, 10.4ZB 2019 Hyperscale

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 61280-4-1 Edition 2.0 2009-06 Fibre-optic communication subsystem test procedures Part 4-1: Installed cable plant Multimode attenuation measurement IEC 61280-4-1:2009(E) THIS

More information

FIA. The Fibreoptic Industry Association. TECHNICAL SUPPORT GUIDE FIA-TSD

FIA. The Fibreoptic Industry Association.  TECHNICAL SUPPORT GUIDE FIA-TSD FIA The Fibreoptic Industry Association www.fibreoptic.org.uk TECHNICAL SUPPORT GUIDE FIATSD000 TESTING INSTALLED CABLING USING OPTICAL TIME DOMAIN RELFECTOMETER (OTDR) EQUIPMENT This document has been

More information

Fibre Optic Connector and Component Standards Developments & Key Issues in IEC & CENELEC. Philip C Longhurst Corporate Fibre Optic R & D Manager

Fibre Optic Connector and Component Standards Developments & Key Issues in IEC & CENELEC. Philip C Longhurst Corporate Fibre Optic R & D Manager Fibre Optic Connector and Component Standards Developments & Key Issues in IEC & CENELEC Philip C Longhurst Corporate Fibre Optic R & D Manager Outline CENELEC TC86BXA work programme IEC SC86B WG 6 and

More information

GUCN. Central Loose Tube Cables Universal Indoor / Outdoor - Corrugated Steel Tape Armor (CST) A/I-DQ(ZN)(SR)H Full Rodent Protection v13.

GUCN. Central Loose Tube Cables Universal Indoor / Outdoor - Corrugated Steel Tape Armor (CST) A/I-DQ(ZN)(SR)H Full Rodent Protection v13. GUCN Central Loose Tube Cables Universal Indoor / Outdoor - Corrugated Steel Tape Armor (CST) A/I-DQ(ZN)(SR)H Full Rodent Protection 07-07-05 v3.0 Ordering Information Belden Part Numbers Fibre Description

More information

TECHNICAL REPORT IEC/TR Fibre optic communication system design guides Part 11: Multimode launch conditions. Edition 1.

TECHNICAL REPORT IEC/TR Fibre optic communication system design guides Part 11: Multimode launch conditions. Edition 1. TECHNICAL REPORT IEC/TR 61282-11 Edition 1.0 2012-05 Fibre optic communication system design guides Part 11: Multimode launch conditions INTERNATIONAL ELECTROTECHNICAL COMMISSION PRICE CODE V ICS 33.180.01

More information

Ensuring Cabling Performance in the Customer-Owned Outside Plant

Ensuring Cabling Performance in the Customer-Owned Outside Plant Ensuring Cabling Performance in the Customer-Owned Outside Plant Needs to be able to qualify the installation to validate bandwidth requirements are met Future high bandwidth applications Future Proof

More information

Sumitomo Fiber Specification SE-6** Non-Zero Dispersion Shifted Single-Mode Fiber. PureGuide SM Optical Fiber, TIA Type IVd. Issued: November 2003

Sumitomo Fiber Specification SE-6** Non-Zero Dispersion Shifted Single-Mode Fiber. PureGuide SM Optical Fiber, TIA Type IVd. Issued: November 2003 Sumitomo Fiber Specification SE-6** Non-Zero Dispersion Shifted Single-Mode Fiber PureGuide SM Optical Fiber, TIA Type IVd Issued: November 2003 78 Alexander Drive, Research Triangle Park, NC 27709 Phone

More information

Qualified Partner Programme QPP. Field-termination of FO connectors Felice Guarna

Qualified Partner Programme QPP. Field-termination of FO connectors Felice Guarna Qualified Partner Programme QPP Field-termination of FO connectors Felice Guarna Introduction Fiber to the Home, Fiber to the Office and Fiber to the Desk are not just slogans and are state of the art

More information

Acceptance Requirements. Fibre Optic Systems. Revised 12/2017. December 5th, Alexander Kölbel

Acceptance Requirements. Fibre Optic Systems. Revised 12/2017. December 5th, Alexander Kölbel December 5th, 2017 Acceptance Requirements Fibre Optic Systems Revised 12/2017 Alexander Kölbel +49 6190 8880-40 alexander.koelbel@datwyler.com Dätwyler Cables GmbH, Auf der Roos 4-12, 65795 Hattersheim,

More information

M310 Enterprise OTDR. Designed for Enterprise Network Testing, Troubleshooting and Documentation. or (800) , (603)

M310 Enterprise OTDR. Designed for Enterprise Network Testing, Troubleshooting and Documentation.  or (800) , (603) Designed for Enterprise Network Testing, Troubleshooting and Documentation Features Industry leading TruEvent analysis Short dead zones provide precise testing of closely spaced events Front Panel and

More information

HELKAMA. Optical Fibre Cables

HELKAMA. Optical Fibre Cables 1 Contents Optical fibres and their characteristics Cable constructions Cable tests Installation, jointing and terminating Manufacturing (pictures) 2 Multimode Fibre (GK) Attenuation and Bandwidth Fibre

More information

SECTION COMMUNICATIONS OPTICAL FIBER BACKBONE CABLING

SECTION COMMUNICATIONS OPTICAL FIBER BACKBONE CABLING SECTION 27 13 23 COMMUNICATIONS OPTICAL FIBER PART 1 - GENERAL 1.1 SUMMARY A. Section Includes the following: 1. 50/125-micrometer, optical fiber cabling. 2. Cable connecting hardware, termination panels,

More information

TESTING HIGH SPEED FIBER LINKS

TESTING HIGH SPEED FIBER LINKS TESTING HIGH SPEED FIBER LINKS Rodney Casteel, RCDD, DCDC, NTS, OSP - CommScope, Chair TIA FOTC Tyler Vander Ploeg - Viavi Solutions Jamie Humphreys - EXFO Rob Gilberti - AFL Jim Davis - Fluke Networks

More information

Fibre Optic Basics FIA Summer Seminar 2014

Fibre Optic Basics FIA Summer Seminar 2014 Fibre Optic Basics FIA Summer Seminar 2014 Andrew Cole Theory Basics Characteristics of Light What is Light? An electromagnetic wave, which like other waves, has a frequency (f), velocity (v) and a wavelength

More information

Simplex ES Network. ES Net Network Applications, Communications, Options and Specifications. ES Net features. UL, ULC Listed*

Simplex ES Network. ES Net Network Applications, Communications, Options and Specifications. ES Net features. UL, ULC Listed* Simplex ES Network UL, ULC Listed* ES Net features ES Network (ES Net) is a high bandwidth (100 Mbps) IP based fire alarm network that supports up to 99 nodes and uses industry standard network technology

More information

GCRG. Multi Loose Tube Cables Universal Indoor / Outdoor A/I-DQ(ZN)BH Improved Rodent Protection v7.0. Ordering Information.

GCRG. Multi Loose Tube Cables Universal Indoor / Outdoor A/I-DQ(ZN)BH Improved Rodent Protection v7.0. Ordering Information. GCRG Multi Loose Tube Cables Universal Indoor / Outdoor A/I-DQ(ZN)BH Improved Rodent Protection 05-05-7 v7.0 Ordering Information Belden Part Numbers Fibre Description / count 4 8 8 4 30 36 6.5/5-OM GCRG04

More information

OptiFiber Pro OTDR Built for the enterprise

OptiFiber Pro OTDR Built for the enterprise OptiFiber Pro OTDR Built for the enterprise As enterprise networks and datacenter architectures evolve, IT infrastructure administrators demand better OTDR technology to maintain fiber network performance.

More information

OPTICAL. Micromodule DW About Us. > IEC nd Ed. According to. > EN nd Ed. FTTx

OPTICAL. Micromodule DW About Us. > IEC nd Ed. According to. > EN nd Ed. FTTx fibrewave About Us Prysmian is a global market leader in optical cables, supplying a major part of the world s optical cable needs. With a strong heritage of highly advanced R&D, Prysmian is at the leading

More information

M210 Multifunction Micro OTDR

M210 Multifunction Micro OTDR Test, Troubleshoot and Document Single-mode and Multimode Fiber Networks Features 30 db dynamic range single-mode 16-hour battery life Remote display capable Touch and Test intuitive user interface New

More information

Telephone and Data Structured Wiring

Telephone and Data Structured Wiring Data Specification Category 6A General Telephone and Data Structured Wiring The Electrical Sub-Contractor shall employ a specialist sub-contractor to provide the following systems:- Manufacturer System

More information

2016 CDM Smith All Rights Reserved July 2016 SECTION FIBER OPTIC DATA NETWORK

2016 CDM Smith All Rights Reserved July 2016 SECTION FIBER OPTIC DATA NETWORK PART 1 GENERAL 1.01 SCOPE OF WORK SECTION 27 12 23 FIBER OPTIC DATA NETWORK A. Furnish, install, terminate, and test all fiber optic equipment and cabling necessary for a complete and functional data highway

More information

M210 Multifunction Micro OTDR

M210 Multifunction Micro OTDR Test, Troubleshoot and Document Single-mode and Multimode Fiber Networks Features 30 db dynamic range single-mode 16-hour battery life Remote display capable Touch and Test intuitive user interface New

More information

Reflectance, The Hidden Danger That Increases Bit Error Rates in Your Fiber Networks Denver, May 22nd, 2010

Reflectance, The Hidden Danger That Increases Bit Error Rates in Your Fiber Networks Denver, May 22nd, 2010 Reflectance, The Hidden Danger That Increases Bit Error Rates in Your Fiber Networks Denver, May 22nd, 2010 Adrian Young Sr. Customer Support Engineer Foreword Reflectance is measured using an Optical

More information

Qualification Test Report LC Duplex Adapter For LC Cutouts

Qualification Test Report LC Duplex Adapter For LC Cutouts Qualification Test Report LC Duplex Adapter For LC Cutouts 501-683 09Mar09 Rev B 1. INTRODUCTION 1.1. Purpose Testing was performed on Tyco Electronics LC Duplex Adapters for LC Cutouts, to determine their

More information

Fiber Optic Distribution Cables (6-144 Fibers)

Fiber Optic Distribution Cables (6-144 Fibers) 900um Buffered Aramid Yarn Strength Members Outer 6 or 12 Subunit Central Strength Member Outer Ripcord Single Unit Cable 6-24 Multi-Unit Cable 24-144 Description: AMP NETCONNECT distribution cables are

More information

The Rise of Tier 2 Testing

The Rise of Tier 2 Testing The Rise of Tier 2 Testing Why enterprises today demand better visibility into their fiber infrastructure Unprecedented demand for more bandwidth, faster network speeds, lower latency, and improved data

More information

OptiFiber Pro OTDR Built for the enterprise

OptiFiber Pro OTDR Built for the enterprise OptiFiber Pro OTDR Built for the enterprise As enterprise networks and datacenter architectures evolve, IT infrastructure administrators demand better OTDR technology to maintain fiber network performance.

More information

Fiber Optic Patch Cord and Pigtails

Fiber Optic Patch Cord and Pigtails Fiber Optic Patch Cord and Pigtails Description The optical fiber patch cords are fitted at both ends with same connector types or different connector types. Our fiber optic patch cords are ultra reliable

More information

Apr06 Rev A

Apr06 Rev A Qualification Test Report LC, Multimode, One-Piece Housing, Fiber Optic Connector 501-628 03Apr06 Rev A 1. INTRODUCTION 1.1. Purpose 1.2. Scope Testing was performed on Tyco Electronics LC multimode, one-piece

More information

Field Testing and Troubleshooting of PON LAN Networks per IEC Jim Davis Regional Marketing Engineer Fluke Networks

Field Testing and Troubleshooting of PON LAN Networks per IEC Jim Davis Regional Marketing Engineer Fluke Networks Field Testing and Troubleshooting of PON LAN Networks per IEC 61280-4 Jim Davis Regional Marketing Engineer Fluke Networks Agenda Inspection and Cleaning APC vs UPC PON basics Wavelengths Architecture

More information

FTTX Solutions Mini Rapid Fiber Distribution Terminal (RDT)

FTTX Solutions Mini Rapid Fiber Distribution Terminal (RDT) TE Connectivity's (TE) FTTX infrastructure solutions are designed from the ground up to meet the unique requirements of FTTX networks. Designed for operational efficiency and scalability, TE s FTTX solutions

More information

Optical Multitester 500 450 OTDR EMEA & APac Edition Issue 1 Page 1 of 10 Description The 450 OTDR is a PC based state-ofthe-art OTDR designed for field applications. It is a dedicated OTDR which offers

More information

Hands-On Fiber Optics ISP/OSP - Advanced Combo- Tech

Hands-On Fiber Optics ISP/OSP - Advanced Combo- Tech Hands-On Fiber Optics ISP/OSP - Advanced Combo- Tech Course Description This Hands-On 3-day course has been customized to provide technicians with a practical understanding of fiber optic theory and fiber

More information

User Manual. Portable 4-Channel Laser Source Instrument in Small Benchtop. (QLDS-N series, version 1.0a. March 26, 2014)

User Manual. Portable 4-Channel Laser Source Instrument in Small Benchtop. (QLDS-N series, version 1.0a. March 26, 2014) User s Fiberprime, Inc. Portable 4-Channel Laser Source Instrument www.fiberprime.com Tel: 1-613-5964030 Email: info@fiberprime.com Fax: 1-613-8289398 Portable 4-Channel Laser Source Instrument in Small

More information

Luna Technologies Webinar Series. New Rayleigh-Based Technique for Very High Resolution Distributed Temperature and Strain Sensing

Luna Technologies Webinar Series. New Rayleigh-Based Technique for Very High Resolution Distributed Temperature and Strain Sensing Luna Technologies Webinar Series New Rayleigh-Based Technique for Very High Resolution Distributed Temperature and Strain Sensing Dr. Dawn Gifford Senior Optical Engineer Mr. Ed Valigursky VP of Sales

More information

M310 Enterprise OTDR. Designed for Enterprise Network Testing, Troubleshooting and Documentation. or (800) , (603)

M310 Enterprise OTDR. Designed for Enterprise Network Testing, Troubleshooting and Documentation.  or (800) , (603) Designed for Enterprise Network Testing, Troubleshooting and Documentation Features Integrated Optical Power Meter and Visual Fault Locator Short dead zones provide testing of closely spaced events Industry

More information

Fiber Optic Products Catalog

Fiber Optic Products Catalog Fiber Optic Products Catalog No epoxy, no polish, no crimp Two fibers in one ferrule MT-RJ Patch Panel Jack packages include: 6 MT-RJ Jacks 2 Actuator Tools 1 Fiber Guide 1 Icon Wheel Bend Limiting Boots

More information

DWDM OTDR with Tunable Laser MTP-200-D100. Hand-held High Performance OTDR. Series

DWDM OTDR with Tunable Laser MTP-200-D100. Hand-held High Performance OTDR. Series MTP-200-D100 Hand-held High Performance OTDR DWDM OTDR with Tunable Laser Series Multi-Function and High Performance OTDR Testing 96 C-band wavelengths Dynamic range up to 38dB Short zone: EDZ 1m, ADZ

More information

Special Provision No. 683S28 December 2017

Special Provision No. 683S28 December 2017 FIBRE OPTIC COMMUNICATION CABLES, AERIAL ON MESSENGER CABLE - Item No. FIBRE OPTIC COMMUNICATION CABLES, AERIAL ON MESSENGER CABLE (TEMPORARY) - Item No. Special Provision No. 683S28 December 2017 1. SCOPE

More information

Product Catalogue. External Management

Product Catalogue. External Management Product Catalogue External Management version 2017 Empowering businesses through innovative network solutions. We have been pushing boundaries and providing innovative products and solutions to clients

More information

TE CONNECTIVITY <fiber count> <fiber type> <flame rating> MM/YY SO<shop order number> XXXXX FEET

TE CONNECTIVITY <fiber count> <fiber type> <flame rating> MM/YY SO<shop order number> XXXXX FEET Optic Backbone Distribution Cables 900um Buffered Aramid Yarn Strength Members Outer 6 or 12 Subunit Central Strength Member Outer Ripcord Single Unit Cable 6-24 Multi-Unit Cable 24-144 Description: TE

More information

Attenuators. Fiber Optic Products Catalog. Singlemode Build Out Attenuators. Product Facts. Applications. Customizable Features. Available Collateral

Attenuators. Fiber Optic Products Catalog. Singlemode Build Out Attenuators. Product Facts. Applications. Customizable Features. Available Collateral Attenuators Build Out Attenuators Product Facts A range of fixed attenuation values. Standard values of 1 through 20 and 25dB UPC and APC offer Excellent Return Loss LC, SC, FC, ST, and D4 styles Attenuation

More information

Qualification Test Report LightCrimp* Plus Singlemode and Multimode LC Connector (Field Installable)

Qualification Test Report LightCrimp* Plus Singlemode and Multimode LC Connector (Field Installable) Qualification Test Report LightCrimp* Plus Singlemode and Multimode LC Connector (Field Installable) 501-586 26Feb09 Rev F 1. INTRODUCTION 1.1. Purpose Testing was performed on Tyco Electronics LightCrimp*

More information

Fire Control Panels. Multiple Signal Fiber Optic Modems and Accessories for Panel and Remote Mounting. Features. Operation.

Fire Control Panels. Multiple Signal Fiber Optic Modems and Accessories for Panel and Remote Mounting. Features. Operation. UL, ULC Approved* Fire Control Panels Multiple Signal Fiber Optic Modems and Accessories for Panel and Remote Mounting Features Converts multiple fire alarm communications signals into a single fiber optic

More information

Applications Engineering Notes

Applications Engineering Notes Applications Engineering Notes Document Title Document Number Revision Number Product Specification and Qualification Test Report: IBC Brand Fiber Optic Connector Cleaner MT38 II AEN-1146 Issue Effective

More information

ASSMANN ELECTRONIC GmbH ASSMANN SYSTEM GUARANTEE. DIGITUS Professional Fiber Optic Cabling System. Appendix B - Provisions for acceptance

ASSMANN ELECTRONIC GmbH ASSMANN SYSTEM GUARANTEE. DIGITUS Professional Fiber Optic Cabling System. Appendix B - Provisions for acceptance ASSMANN ELECTRONIC GmbH ASSMANN SYSTEM GUARANTEE DIGITUS Professional Fiber Optic Cabling System Appendix B - Provisions for acceptance Page 1 Table of contents 1. Acceptance test of the installation link

More information

Hands-On Fiber Optic ISP / OSP Combo-Tech Splicing, Termination & Testing

Hands-On Fiber Optic ISP / OSP Combo-Tech Splicing, Termination & Testing Hands-On Splicing, Termination & Testing BICSI CECs This course has been approved for CEC credits by BICSI. Please read below for a breakdown of the credits that we offer for this course. For more information

More information

Datasheet: OptiFiber Pro OTDR

Datasheet: OptiFiber Pro OTDR Datasheet: OptiFiber Pro OTDR Accelerates enterprise fiber troubleshooting and certification. The OptiFiber Pro OTDR is the Tier 2 (extended) fiber certification solution and part of the Versiv Cabling

More information

industry solutions: military

industry solutions: military industry solutions: military MC industry Solutions: Military A tradition of leadership in technology, product performance for military applications Optical Cable Corporation is a leading manufacturer of

More information

Universal Connectivity Platform A Modular Approach to Infrastructure Design

Universal Connectivity Platform A Modular Approach to Infrastructure Design A Modular Approach to Infrastructure Design TE Connectivity s Universal Connectivity Platform (UCP) provides a fully modular approach to designing data centers and telecommunications rooms. This patch

More information

Certified Fibre Optic Specialist - Testing

Certified Fibre Optic Specialist - Testing Certified Fibre Optic Specialist - Testing COURSE DESCRIPTION: This training program is designed to introduce the student to the process of fibre optic network testing. It is intended for those looking

More information

Noyes OFL 250B Specs Provided by

Noyes OFL 250B Specs Provided by Noyes OFL 250B Specs Provided by www.aaatesters.com OFL 250 Handheld OTDR The Noyes OFL 250 from AFL Telecommunications is a single-mode OTDR with an integrated Optical Power Meter (OPM), Source (OLS),

More information

FIA-TSD OPTICAL FIBRE - DISPOSAL OF WASTE

FIA-TSD OPTICAL FIBRE - DISPOSAL OF WASTE TECHNICAL SUPPORT GUIDE FIATSD000 This document has been reissued (version.0) to reflect the change in FIA website details, to update the list of FIA Technical Support Documents (both published and in

More information

GUSN. Central Loose Tube Cables (Distribution) Universal Indoor/ Outdoor A/I-DQ(ZN)BH Standard Rodent Protection. Ordering Information.

GUSN. Central Loose Tube Cables (Distribution) Universal Indoor/ Outdoor A/I-DQ(ZN)BH Standard Rodent Protection. Ordering Information. GUSN Central Loose Tube Cables (Distribution) Universal Indoor/ Outdoor A/I-DQ(ZN)BH Standard Rodent Protection Ordering Information Belden European Part Numbers Fibre type / count 2 4 6 8 12 16 24 62.5/125-OM1

More information

Fujikura-70S Single Fibre Fusion Splicer

Fujikura-70S Single Fibre Fusion Splicer Fujikura- Single Fibre Fusion Splicer Features Core-to Core alignment, Dual Axis observation system. World s quickest splicing 6sec. / tube-heating 9sec. Minimal manual operation. Splice in 4 steps. Multi-functional

More information

Clearlite Photonic Fibers

Clearlite Photonic Fibers Clearlite Photonic Fibers Fiber Name Operating Wavelength MFD at Operating Wavelength Beat Length at Operating WL Clad/Coating Diameter Order by Part Number TruePhase 980 Micro TruePhase 980 400 TruePhase

More information

LAB REPORT SUBMISSION COVER PAGE ETN4106 OPTOELECTRONICS AND OPTICAL COMMUNICATIONS

LAB REPORT SUBMISSION COVER PAGE ETN4106 OPTOELECTRONICS AND OPTICAL COMMUNICATIONS 1/10 FACULTY OF ENGINEERING LAB REPORT SUBMISSION COVER PAGE ETN4106 OPTOELECTRONICS AND OPTICAL COMMUNICATIONS TRIMESTER 3, SESSION 2016/2017 Student Name: Student ID: Degree Major (please circle): EE

More information

M700-Series Multifunction OTDR

M700-Series Multifunction OTDR M700-Series Multifunction OTDR Test, Troubleshoot and Document Single-mode and Multimode Fiber Networks Test Modes Full Auto OTDR Normal (point-to-point) fiber cable construction testing and fault location

More information

STANDARD CONFORMANCE

STANDARD CONFORMANCE STANDARD CONFORMANCE IEC 60331-11, Tests for electric cables under fire conditions- Circuit integrity- Fire alone at a flame temperature of at least 750C IEC 60331-21, Tests for electric cables under fire

More information

Connections You Can Count On.

Connections You Can Count On. Connections You Can Count On. XPRESS ULTRA FIBER CONNECTOR PRODUCT GUIDE - CLEANING & INSPECTION - TESTING AND TROUBLE SHOOTING - XPRESS ULTRA FIBER CONNECTORS - INSTALLATION KITS Connections You Can Count

More information

A Quick Start Guide to Fiber-to-theAntenna (FTTA) Installation and Maintenance Testing. Vol. 2 Tier 2 Certification

A Quick Start Guide to Fiber-to-theAntenna (FTTA) Installation and Maintenance Testing. Vol. 2 Tier 2 Certification A Quick Start Guide to Fiber-to-theAntenna (FTTA) Installation and Maintenance Testing Vol. 2 Tier 2 Certification A Quick Start Guide to Fiber-to-the-Antenna enna (FTTA) Installation and Maintenance Testing

More information

Characterization of High Speed Optical Detectors for Purpose of OM4 Fibre Qualification: Selective Mode Detection

Characterization of High Speed Optical Detectors for Purpose of OM4 Fibre Qualification: Selective Mode Detection Characterization of High Speed Optical Detectors for Purpose of OM4 Fibre Qualification: Selective Mode Detection F. J. Achten 1 and D. Molin 2 1 Prysmian Group, Zwaanstraat 1, 5651CA Eindhoven, Netherlands

More information

Duct Cable GYTS-144B1.3

Duct Cable GYTS-144B1.3 Optical Fibre Cable Technical Specification Duct Cable GYTS-144B1.3 Xcom Ltd All rights reserved 1. Scope This Specification covers the design requirements and performance standard for the supply of optical

More information

The True Value of Connector Inspection: New Challenges and Best Practices

The True Value of Connector Inspection: New Challenges and Best Practices The True Value of Connector Inspection: New Challenges and Best Practices Vincent Racine Product Line Manager August 2011 1 Table of contents 1 Best Practices 2 Connector Inspection Tools 3 Connector Inspection

More information

FACULTY OF ENGINEERING LAB SHEET OPTICAL COMMUNICATION SYSTEMS EOP4066 TRIMESTER 1 (2013/2014)

FACULTY OF ENGINEERING LAB SHEET OPTICAL COMMUNICATION SYSTEMS EOP4066 TRIMESTER 1 (2013/2014) FACULTY OF ENGINEERING LAB SHEET OPTICAL COMMUNICATION SYSTEMS EOP4066 TRIMESTER 1 (2013/2014) OC1 FIBER LINK CHARACTERIZATION WITH OTDR *Note: On-the-spot evaluation may be carried out during or at the

More information

Kingfisher KI-3800 Light Source. Inexpensive handheld source for testing and commissioning optical fibre networks. Compact and rugged,

Kingfisher KI-3800 Light Source. Inexpensive handheld source for testing and commissioning optical fibre networks. Compact and rugged, TEST EQUIPMENT POWER METERS, LIGHT SOURCES Kingfisher KI-9800 Light Source Kingfisher KI-3800 Light Source Inexpensive handheld source for testing and commissioning optical fibre networks. Compact and

More information

The Optical Time Domain Reflectometry and the Fusion Splicer Laboratory exercise

The Optical Time Domain Reflectometry and the Fusion Splicer Laboratory exercise The Optical Time Domain Reflectometry and the Fusion Splicer Laboratory exercise 1 The purpose of the exercise...2 2 Background...2 2.1 Introduction to scattering and attenuation...2 2.2 Introduction to

More information

A Quick Start Guide to Fiber-to-the-Antenna (FTTA) Installation and Maintenance Testing. Vol. 2 Tier 2 Certification

A Quick Start Guide to Fiber-to-the-Antenna (FTTA) Installation and Maintenance Testing. Vol. 2 Tier 2 Certification A Quick Start Guide to Fiber-to-the-Antenna (FTTA) Installation and Maintenance Testing Vol. 2 Tier 2 Certification Notice Copyright Every effort was made to ensure that the information in this document

More information

Fire Control Panels. Multiple Signal Fiber Optic Modems and Accessories for 4120 Network. UL, ULC, CSFM Listed; FM Approved* Features

Fire Control Panels. Multiple Signal Fiber Optic Modems and Accessories for 4120 Network. UL, ULC, CSFM Listed; FM Approved* Features Fire Control Panels UL, ULC, CSFM Listed; FM Approved* Features Compatible with Simplex 4120 Network Converts multiple 4120 network communications signals into a single fiber optic link to: Multiplex audio

More information

PUMP AND SIGNAL COMBINERS

PUMP AND SIGNAL COMBINERS Pump and Signal Combiners For Fiber Laser and Amplifier Design A Furukawa Company www.ofsoptics.com PUMP AND SIGNAL COMBINERS for Fiber Laser and Amplifier Design Multimode Single-mode Polarization-Maintaining

More information