Selection of Explosion Protected Equipment for Hazardous Locations. Compiled by: Pieter Coetzee ZONE 2 ZONE 1 ZONE 0.
|
|
- Thomasina Eaton
- 5 years ago
- Views:
Transcription
1 Selection of Explosion Protected Equipment for Hazardous Locations Compiled by: Pieter Coetzee ZONE 2 ZONE 0 ZONE 1 Be safe be Ex
2 Contents Introduction Occupational Health and Safety Act. (Act 85 of 1993) & ARP 0108 Area Classification Equipment Protection Levels (EPL) Temperature Classification Different Ex Techniques Marking of Ex Equipment Selection of EPE Conclusion
3 Introduction Hazardous Location Definition An area in which an explosive gas atmosphere or combustible dust, in the form of a cloud is present, or may be expected to be present, in quantities such as to require special precautions for the construction, installation and use of equipment Explosion protected descriptive of electrical apparatus designed and approved for use in hazardous locations in accordance with a suitable protection method, including Ex d, Ex i, Ex e, Ex p, Ex na, Ex s, Ex m and Ex q
4 Three components are required for an explosion or fire to occur Oxygen Flammable Substance Ignition Source
5 Possible results from explosions, incidents and fires Includes Loss of life Loss of production (Financial Impact) Damage to plants Environmental impact
6 Occupational Health and Safety Act. (Act 85 of 1993) Act The Act shall refer to the latest issue of the Occupational Health and Safety Act 85/1993 (OHSA). To meet safety requirements as per section 44 of the OHS Act. (EMR 9(1)) Every employer or user shall identify all hazardous locations and classify them in accordance with the relevant health and safety standard incorporated into these Regulations under section 44 of the act.
7 Occupational Health and Safety Act. (Act 85 of 1993) To ensure legal compliances at all time EMR 9(3) requires that: every employer or user referred to in sub regulation (1) shall be in possession of a certificate in a form acceptable to the chief inspector which has been issued by an approved inspection authority and in which it is certified that the electrical machinery referred to in sub regulation (2) has been manufactured and tested for the groups of dangerous articles in accordance with the relevant health and safety standard incorporated into these Regulations under section 44 of the Act: Provided that in lieu of such certificate an inspector may approve permanent labelling on such machinery, which label shall contain all the relevant information.
8 ARP 0108 Annex c Upgrading and maintenance of EPE certificates for mines and factories C.1 In South Africa, all EPE used in underground mines (Group I) and on surface (Group II) shall be covered by an IA certificate. The requirements in C.2 to C.15 cover the validity of IA certificates. C.2 All IA certificates issued shall have a validity period of 10 years. Where a product is in service and its certificate has expired it will not be affected. IA certificates based on overseas certification will be valid for a period of one year
9 Responsibilities and Authorities Description Regulation Standard Responsibility Area Classification EMR 9(1) EIR 4(1) Selection of Ex equipment EMR 9(1) EIR 4(1) Installation of Ex equipment EMR 9(1) EMR 9(2) SANS SANS SANS SANS EIR 4(1) Certification of Ex equipment EMR 9(1) SANS Maintenance and inspection of Ex equipment EMR 9(8) EIR 2(1) ARP 0108 SANS SANS Plant owner (Competent personnel; committees or consultant) Production Manager Plant owner and projects ( Engineering) Electrical Engineering Manager Plant owner done by own personnel or contractors SGI-MOR Approved test Laboratory(ATL) Plant owner( All Ex equipment must be inspected every two years) OSH ACT Repair of Ex equipment EIR 2(1) SANS SANS Approved test Laboratory(ATL) SABS; EXPLOLABS; MASC Certificate of compliance(coc) - SANS MIE test installation and make sure it complies and then issue a COC Mechanical Equipment EN & 3 Mechanical
10 Area Classification /Map
11 Important information on Area Classification drawing/map
12 Important information on Area Classification drawing /Map
13 Three zones for gases and vapours Substance Zones Frequency of formation of explosive atmosphere Gases and Vapours 0 Location in which an explosive gas/vapours or mist atmosphere is present continuously or for long periods. 1000hrs + per year 1 Location in which an explosive gas/vapours or mist atmosphere is likely to occur in normal operation hrs per year 2 Location in which Gas/Vapours or mist atmospheres present during abnormal circumstances hrs per year Examples Zone 0 is not found in the open air but inside vessels or badly ventilated rooms. Zone 1 are normally small volumes found around sample points or pump seals at certain frequency a day.(eg. Twice a day) Large part of the plant is normally a Zone 2 area for eg. abnormalities at flanges or sample points. Zone 0 is the most severe zone (the highest probability of flammable atmosphere presence). Equipment for this zone requires the most stringent protection against providing a source of ignition.
14 Example of a typical zone activity would be filling a barrel of petrol in an enclosed area Zone 2 Zone 0 Zone 1 Zone 1 Zone 0 Zone 0 Zone 1 Zone 2 Present continuously or for long periods Likely to occur in normal operation Present during abnormal circumstances. 1000hrs + per year hrs per year hrs per year
15 Area divided into Zones Zone 0 Zone 1 Zone 2 Present continuously or for long periods. 1000hrs + per year Likely to occur in normal operation hrs per year Present during abnormal circumstances hrs per year Vent Bund Wall Liquid
16 Flammable substance Hazardous areas are defined by three main criteria: The type of hazard The likelihood of the hazard being present in flammable concentrations The (auto) ignition temperature of the hazardous material The type of hazard (Groups) The hazard will be in the form of a gas, vapour, dust or fibre. Gases and Vapours (Group I/II) Gases and vapours are categorized in terms of their ignition energy or the maximum experimental safe gap (in respect of flameproof protection). This categorization leads to the Gas Groups:
17 Gas Groups Industry Mining Industry Group I Surface Industry Group II Gas Group I IIA Substance MIE Selection of equipment Methane 200µJ Equipment only suitable for mines unless it is additional approved for surface: Marked I/IIC Propane 180 µj and higher IIA; IIB and IIC certified equipment may be use in an IIA area. IIB Ethylene 60 µj -180 µj IIB and IIC certified equipment may be used in an IIB area. IIC Hydrogen 20 µj 60 µj Only IIC certified equipment is allowed to be used in an IIC area. (The gases noted in the table are typical gases for each group.) MIE Minimum ignition energy Gas Group IIC is the most severe gas group
18 Temperature Classes Explosion proof equipment, installed within the Ex area, is divided into 6 temperature classes (T1 to T6). Temperature class is not as it is often wrongly believed the operating temperature range of the equipment, but the maximum permissible surface temperature of the equipment, in relation to + 40 C ambient temperature on any surface area, and should not be exceeded at any time. The maximum surface temperature must remain below the ignition temperature of the surrounding medium at all times. The equipment requirements increases from T1 to T6. T-Class Maximum surface temperature of the equipment Ignition temperatures of combustible substances T1 450 C > 450 C T2 300 C > 300 C T3 200 C > 200 C T4 135 C > 135 C T5 100 C > 100 C T6 85 C > 85 C
19 Auto-ignition temperatures (vapours/gases and dust) Vapours/gases Gas Temperature Methane 580 C Hydrogen 560 C Propane 493 C Ethylene 425 C Acetylene 305 C Naphtha 290 C Carbon disulfide 102 C Dust Substance Temperature Sugar 460 C Wood 340 C Flour 340 C Grain dust 300 C Tea 300 C
20 Equipment Protection Level (EPL) Group Ex risk Zone EPL I (mines) energized Ma I (mines) de-energized in presence of Ex atmosphere Mb Minimum type of protection II (gas) II (gas) II (gas) explosive atmosphere > 1000 hrs/yr explosive atmosphere between 10 and 1000 hrs/yr explosive atmosphere between 1 and 10 hrs/yr 0 Ga ia, ma 1 Gb ib, mb, px, py, e, o, q, s 2 Gc n, ic, pz III (dust) III (dust) III (dust) explosive surface > 1000 hrs/yr explosive surface between 10 and 1000 hrs/yr 20 Da 21 Db explosive surface between 10 and Dc
21 Different Ex Techniques Technique Protection Type Symbol Application Typical application Energy Limiting Intrinsic Safety Ex ia Zone o Instrumentation; Ex ib Zone 1 control gear Ex ic Zone 2 Ex iad Zone 20 Containment Flameproof Ex d Zone 1 & 2 Switchgear; motors; pumps Principle Refined Mechanical design Refined Mechanical design Segregation (Isolation) Increase Safety Ex e Zone 1 & 2 Motors; Light fittings Non-sparking Ex na Zone 2 Motors; Light fittings Pressurization Exp; Ex pd Zone 1& 2 Zone 21 Motors; analysers; control rooms Segregation (Isolation) Encapsulation Ex m; Ex md Zone 1& 2 Zone 20 Solenoids; fuses; relays Segregation (Isolation) Sand filling Ex q Zone 1 & 2 Strip heaters, capacitors
22 Marking of Ex equipment E Ex ia IIC T6 Ga Equipment protection level (EPL) Temperature Classification (T-Class) identifies the maximum ignitioncapable surface temperature which the equipment will exhibit.(t6 =85 C) Unless otherwise stated, the maximum ambient temperature to which the equipment may be subjected (and thus the maximum ambient temperature for which the T-Class will be true) is 40 C Gas Group/Apparatus Group The roman II indicates surface industry (not mining). IIC is the most onerous subgroup in Group II. Equipment which is suitable for IIC will also be suitable for IIA and IIB Code letters indicate the type of protection (or types) of protection utilized by this equipment. ia indicates Intrinsic Safety Ex: is the symbol for explosion protection The initial E indicating conformity with European EN standards. This E is no longer used so it will not be shown on equipment which has been designed and certified since around 2007
23 Selection of EPE for hazardous location Equipment marking Ex d IIC T5 Gb - 20 to 40 C Verification sheet Area Equipment Compliance Zone 1 d (Gb) Suitable Gas Group IIB IIC Suitable Temperature class T4 T5 Suitable Ambient temperature - 20 to 40 C - 20 to 40 C Suitable
24 Conclusion
Legislation associated with Hazardous Locations. Pieter Coetzee ZONE 2 ZONE 1 ZONE 0. Be safe be Ex
Legislation associated with Hazardous Locations Pieter Coetzee ZONE 2 ZONE 0 ZONE 1 Be safe be Ex Contents History Introduction Occupational Health and Safety Act. (Act 85 of 1993) General Machinery Regulation
More informationHazardous Areas - EXPLOSIONPROOF SOLENOIDS
Hazardous Areas - EXPLOSIONPROOF SOLENOIDS SOME HISTORY The classification of hazardous areas into zones established the level of protection required for electrical equipment installed in explosive gas
More informationAiro Wireless Intrinsically Safe White Paper. Written By: David Schmitt
Airo Wireless Intrinsically Safe White Paper Written By: David Schmitt Intrinsically Safe Cell Phone/Smartphone/PDA Intrinsically Safe (IS) is a protection certification for safe operation with electronic
More informationUL HAZARDOUS LOCATIONS SERVICES
UL HAZARDOUS LOCATIONS SERVICES The international preference in hazardous locations certification for over 100 years ul.com/hazloc Explosive Gas Atmospheres Class I Division S Includes flammable gases,
More informationGuide for hazardous areas
Guide for hazardous areas 1 Hazardous areas definitions 2 Gas and dust s 3 Temperature classifications 4 Common flammable gases, vapours and dust types 5 Protection concepts ATEX and IECEx 6 Protection
More informationBeamex. Calibration White Paper. Calibration in hazardous areas
Beamex Calibration White Paper info@beamex.com Calibration in hazardous areas This article discusses calibration in hazardous areas and what everyone needs to be aware of before entering into a hazardous
More informationThe R. STAHL Technology Group Worldwide Success with Competence and Customer Support
The R. STAHL Technology Group Worldwide Success with Competence and Customer Support The entrepreneurial basis of the R. STAHL Technology Group follows a long tradition. The product range is aimed at specialised
More informationBeamex Calibration White Paper. Calibration in hazardous areas
Beamex Calibration White Paper info@beamex.com Calibration in hazardous areas This article discusses calibration in hazardous areas and what everyone needs to be aware of before entering into a hazardous
More informationREGULATIONS EUROPEAN ATEX DIRECTIVE. INTERNATIONAL SCHEME: IECEx AREAS CLASSIFICATION DEFINED BY DIRECTIVE 1999/92/EC
EUROPEAN ATEX DIRECTIVE > European Directive 2014/34/EU ATEX Directive 2014/34/EU is a "new approach" directive that applies to protective systems against explosions as well as all equipment used in or
More informationNZQA registered unit standard version 1 Page 1 of 5. Install fixed gas detection apparatus in hazardous areas
Page 1 of 5 Title Install fixed gas detection apparatus in hazardous areas Level 4 Credits 2 Purpose This unit standard covers the installation, calibration, and response checking of fixed gas detection
More informationOverview of Hazardous Locations as They Relate to Solenoid Valves
Overview of Hazardous Locations as They Relate to Solenoid Valves Defined: Hazardous Location - "where fire or explosion hazards may exist due to flammable gases or vapors, flammable liquids, combustible
More informationWeighing Solutions for Hazardous Areas FULL COMPLIANCE WITH ATEX DIRECTIVE
Weighing Solutions for Hazardous Areas FULL COMPLIANCE WITH ATEX DIRECTIVE PUE HX5.EX explosion-proof hazardous area indicator ATEX APPROVAL PUE HX5.EX is a cutting-edge weighing indicator, designed to
More informationHAZARDOUS AREA CLASSIFICATION AND SELECTION OF EQUIPMENT FOR SAFE USE THEREIN FROM AN ELECTRICAL VIEWPOINT
HAZARDOUS AREA CLASSIFICATION AND SELECTION OF EQUIPMENT FOR SAFE USE THEREIN FROM AN ELECTRICAL VIEWPOINT Olof Bekker Pr. Eng. BSc. Eng. BML S.MSAIEE, M.NACE Engineering Manager, Electrical COMMITMENT
More informationHazardous Area Classification in Oil & Gas Industry. A Fire Prevention Tool
Hazardous Area Classification in Oil & Gas Industry A Fire Prevention Tool SFPE ENGINEERING TECHNOLOGY CONFERENCE Oct 4, 2010 New Orleans, LA 1 Overview Oil and gas plants handle flammable materials 2
More informationATEX, NOMENCLATURE AND CODING
Technical Notes ATEX, NOMENCLATURE AND CODING The intent of this technical note is approach to the user to the ATEX normative. For this we will begin defining, what is an explosive atmosphere, what are
More informationHOW TO FIND THE RIGHT DEVICE FOR YOUR FACILITY
HOW TO FIND THE RIGHT DEVICE FOR YOUR FACILITY Cell Phones Smartphones PDA integrating people, products and processes Intrinsically Safe Cell Phone/Smartphone/PDA Intrinsically Safe (IS) is a protection
More informationElectrical Installations Design, Selection, Erection and Inspection
IECEx International Conference 2018 Jakarta, Indonesia Electrical Installations Design, Selection, Erection and Inspection IECEx International Conference 2018 Jakarta, Indonesia Peter Thurnherr thuba Ltd.,
More informationGuide to Hazardous Location Approvals:
Selection Guide Guide to Hazardous Location Approvals: MICRO SWITCH Hazardous Area Limit Switches Introduction There are many considerations when selecting a switch to be used in hazardous areas. In addition
More informationGuide to Hazardous Location Approvals: MICRO SWITCH Hazardous Area Limit Switches
Guide to Hazardous Location Approvals: MICRO SWITCH Hazardous Area Limit Switches A Selection Guide Introduction There are many considerations when selecting a switch to be used in hazardous areas. In
More informationWHAT WHITE PAPER IS POTENTIALLY EXPLOSIVE ATMOSPHERE CERTIFICATION AND WHY YOU. June 2010
WHITE PAPER WHAT IS POTENTIALLY EXPLOSIVE ATMOSPHERE CERTIFICATION AND WHY YOU MAY NEED IT! June 2010 Copyright Extronics Ltd 2010 The information contained in this document is subject to change without
More informationATEX, NOMENCLATURE AND CODING
ATEX, NOMENCLATURE AND CODING The intent of this technical note is approach to the user to the ATEX normative. For this we will begin defining, what is an explosive atmosphere, what are ATEX, as well as
More informationTECHNICAL SOLUTIONS APPLICABLE TO ELECTRICAL EQUIPMENTS DESIGNED FOR USE IN EXPLOSIVE GAS ATMOSPHERES
TECHNICAL SOLUTIONS APPLICABLE TO ELECTRICAL EQUIPMENTS DESIGNED FOR USE IN EXPLOSIVE GAS ATMOSPHERES TECHNICAL SOLUTIONS APPLICABLE TO ELECTRICAL EQUIPMENTS DESIGNED FOR USE IN EXPLOSIVE GAS ATMOSPHERES
More informationIntrinsically Safe Solutions
Intrinsically Safe Solutions INSTALLATION MANUAL 04/12/14 Rev D DOC-01-029 Documentation Feedback Your feedback helps us keep our documentation up to date and accurate. If you have any comments or suggestions
More informationIECEx International Conference 2017 Shanghai, China. Electrical Installations Design, Selection, Erection and Inspection
IECEx International Conference 2017 Shanghai, China Electrical Installations Design, Selection, Erection and Inspection IECEx International Conference 2017 Peter Thurnherr Shanghai thuba Electric Co. Ltd.,
More informationErik Leider Project Engineer Hazardous Locations, Gas & Oil Underwriters Laboratories
Hazardous Locations: Understanding the Basics of Global Compliance Requirements Erik Leider Project Engineer Hazardous Locations, Gas & Oil Underwriters Laboratories DISCLAIMER/ TERMS OF USE: THE INFORMATION
More informationA guide to the use of electrical equipment in potentially explosive atmospheres To view this document in PDF format click here.
A guide to the use of electrical equipment in potentially explosive atmospheres To view this document in PDF format click here Introduction Potentially Explosive Atmospheres exist where there is a risk
More informationMICROpeL 75 Combustible Gas Sensor Part Number: PM
MICROpeL 75 Combustible Gas Sensor Part Number: PM759-000 Key Features & Benefits: ATEX, UL and CSA Approvals Withstands EN/IEC 60079-0 impact test Enhanced H 2 S and silicone poison resistance Reduced
More informationCLASS I LOCATIONS ZONE CLASSIFICATION
HAZARDOUS (CLASSIFIED) LOCATIONS Hazardous locations are those locations where the risk of a fire or explosion may exist due to the presence of flammable gases or vapors, flammable liquids, combustible
More informationCONSULTING Training Courses
CONSULTING Training Courses 2 EXPLOLABS TRAINING MAKES THE DIFFERENCE 1. GENERAL Why training by Explolabs Consulting? For training in the specialized, high-risk field of explosion protection, one needs
More informationGuidelines for Market Surveillance of Equipment for Explosive Environments (Hazardous Locations)
Annex II Guidelines for Market Surveillance of Equipment for Explosive Environments (Hazardous Locations) 1. According to Recommendation L, market surveillance should be included as a flanking area of
More informationExplosion-protected actuator Page 259 of 292
Explosion-protected actuator Page 259 of 292 9.5 Explosion-protected actuator 9.5.1. What is an explosion? A flammable substance and oxygen, in a certain mixture, must be available to set off an explosion.
More informationGuide to Intrinsically Safe Portable Radios
Guide to Intrinsically Safe Portable Radios An overview of common IS standards www.taitradio.com GUIDE TO INTRINSICALLY SAFE PORTABLE RADIOS SUMMARY The development of equipment for explosive atmospheres
More informationATEX - GUIDE. A short introduction to ATEX Terminology. Equipment for use in flammable atmospheres C E R T I F I E D DANISH TECHNOLOGICAL INSTITUTE
DANISH TECHNOLOGICAL INSTITUTE The Danish Technological Institute is a self-owned and not-f-profit institution. We develop, apply and disseminate research- and technologically-based knowledge f the Danish
More informationEquipment and Solutions
Equipment and Solutions Solution [formally technor atex] Subject to errors or changes Editing completed January 2016 Ex-tech Group is located at Forus in Stavanger, Norway, one of the world s top Centers
More information1. GENERAL TECHNICAL INFORMATION
1. GENERAL TECHNICAL INFORMATION 1.1 EXPLOSIVE ATMOSPHERES: Every time that dangerous quantities and concentration of flammable gas, vapors mixture or dust clouds exists, risk of explosions may arise.
More informationATEX - GUIDE. A short introduction to ATEX Terminology. Equipment for use in flammable atmospheres
Quick Introduction to: DANISH TECHNOLOGICAL INSTITUTE The Danish Technological Institute is a self-owned and not-fprofit institution. We develop, apply and disseminate research- and technologically-based
More informationDual certification! Air handling units for potentially explosive atmospheres
Dual certification! Air handling units for potentially explosive atmospheres X-CUBE Ex A certified safety product The air handling unit with dual ATEX certification ATEX directive 2014/34/EU applies to
More informationSOUTH AFRICAN NATIONAL STANDARD
ISBN 978-0-626-30262-7 SOUTH AFRICAN NATIONAL STANDARD The installation, inspection and maintenance of equipment used in explosive atmospheres Part 1: Installations including surface installations on mines
More informationAS/NZS :2009 Explosive atmospheres - Part 14: Electrical installations design, selection and erection
Skip to main content Skip to primary navigation Home Home About this portal Latest updates Menu Print Save Email Resource detail Citations AS/NZS 60079.14:2009 Explosive atmospheres - Part 14: Electrical
More informationEUROPEAN DIRECTIVES Explosive atmospheres ATEX 2014/34/EU
EUROPEAN DIRECTIVES Explosive atmospheres ATEX 2014/34/EU GENERAL The accidental ignition of an atmosphere containing a large quantity of gas, vapour, mists and/or dust may cause an explosion. Specific
More informationExplosion protection Marijan Gorše, dipl. ing.
Explosion protection Marijan Gorše, dipl. ing. 1/18 Flammable Gas Atmosphere We Can Control Them Explosion hazards mostly arise from flammable gases and vapours. Instead of avoiding their ignition by explosion
More informationUnderstanding Hazardous Locations Concepts
Gas Well Deliquification Workshop Sheraton Hotel, February 23 26, 2014 Understanding Hazardous Locations Concepts Mark Scantlebury, P. Eng., BASc President and CEO Extreme Telematics Corp. Disclaimer The
More informationATEX GUIDE. A short introduction to ATEX Terminology. Equipment for use in flammable atmospheres. Directive 94/9/EC
Quick Introduction to TÛV Denmark TÜV Denmark - is a part of the TÜV NORD Group a global Organisation f Certification and Inspection of: Quality Management Systems, Products, Processes and Qualification
More informationS T R I T T & P R I E B E I N C.
Equipment Enclosure Comparisons Type of Enclosure European - Area of use Designation Standard IEC - Area of use Designation Standard USA - Area of use Designation Standard Flameproof Enclosure An enclosure
More informationTechnical Data. General specifications Switching element function Rated operating distance s n 4 mm
0102 Model Number Features 4 mm non-flush Accessories BF 12 Mounting flange, 12 mm Technical Data specifications Switching element function NAMUR, NO Rated operating distance s n 4 mm Installation non-flush
More informationPYROS. Código: FT-PY01-I Revisión: TECHNICAL DATA. Polycarbonate tube of 4 mm. thickness LIGHT FITTING. Laquered steel painted white
. TECHNICAL DATA LIGHT FITTING REFLECTOR Polycarbonate tube of 4 mm. thickness Laquered steel painted white END CAPS Aluminium 2030 (polyester paint RAL 7047) POWER SOURCE LAMP TYPE 220-240V, 50/60Hz T8
More informationExplosive. Atmospheres. Safety and Reliability
Explosive Atmospheres Safety and Reliability Explosive Atmospheres When it comes to hazardous areas, the utilisation of suitable products and their proper maintenance are mandatory requirements in order
More informationESSENTIAL EXPLOSION PROTECTION
ESSENTIAL EXPLOSION PROTECTION 2 3 FOREWORD In many industries, gases, vapours, mist and dust develop and escape in the course of manufacturing, processing, transporting and storing combustible substances.
More informationNCS/SAS IAS/PES Chapter Seminar January 25-27, Hazardous Locations. OBIEC Consulting George Morlidge Fluor Canada
January 25-27, 2016 Hazardous Locations Marty Cole Tim Driscoll Hubbell Canada OBIEC Consulting George Morlidge Fluor Canada 1 Hazardous Locations - Agenda Canadian Electrical Code 2015 Changes What s
More informationINTERNATIONAL STANDARD
IEC 61892-7 INTERNATIONAL STANDARD Edition 2.0 2007-11 Mobile and fixed offshore units Electrical installations Part 7: Hazardous areas INTERNATIONAL ELECTROTECHNICAL COMMISSION PRICE CODE XA ICS 47.020.60
More informationHazardous Location Surge Protection Solutions
Hazardous Location Surge Protection Solutions Agenda PolyPhaser Transtector Market Leaders Hazardous Locations Class I Division 2 Qualifications and Definitions Impacts to Your Business Hazardous Applications
More informationOPTIWAVE X500 Supplementary Instructions
OPTIWAVE X500 Supplementary Instructions OPTIWAVE 3500 C OPTIWAVE 6500 C OPTIWAVE 7500 C Supplementary Instructions for ATEX applications KROHNE CONTENTS OPTIWAVE X500 1 General safety information 4 1.1
More informationHazardous area descriptions
Hazardous area descriptions National Electrical Code (NEC) 500 Traditional standards used in North America. Example: Class I, Div 1, Group B, C, D, T4 Permitted Class Permitted Division Permitted Group
More informationINSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon
INSTRUCTION MANUAL Minialite Intrinsically Safe Round LED This instruction sheet describes installations which conform to EN60079:Part14:2008 Electrical Installation in Hazardous Areas. When designing
More information[ TECHNOLOGY ] and does this definition affect a burner.
[ TECHNOLOGY ] JBD-11,500-G type burner for natural gas ATEX, EExd Zone 2. For combined cycle power plant in Riga Latvia. Aitor Fernández Project Engineer Automation Department Head afernandez@emcombustion.es
More informationDrive Technology \ Drive Automation \ System Integration \ Services * _0817* Inquiry Forms for Explosion-Proof Gearmotors
Drive Technology \ Drive Automation \ System Integration \ Services *23511257_0817* Inquiry Forms for Explosion-Proof Gearmotors Edition 08/2017 23511257/EN SEW-EURODRIVE Driving the world Inquiry forms
More informationSeat Ventilation offers an extensive range of ATEX certified products and is undertaking great efforts to extend this range even further.
ATEX SOLUTIONS In order to apply a single level for health and safety requirements and to overcome barriers of trade within Europe, national regulations for explosion prevention were harmonized in 1975
More informationOPTIBAR DP 7060 Supplementary Instructions
OPTIBAR DP 7060 Supplementary Instructions Differential pressure transmitter Category ATEX II 1/2G, 2G Ex db ia IIC T6...T1 Ga/Gb, Gb IECEx Ex db ia IIC T6...T1 Ga/Gb, Gb Housing Aluminium: Single chamber,
More informationA GUIDE TO EUROPEAN (EEC) CERTIFICATION FOR ELECTRICAL EQUIPMENT IN HAZARDOUS AREAS
A GUIDE TO EUROPEAN (EEC) CERTIFICATION FOR ELECTRICAL EQUIPMENT IN HAZARDOUS AREAS For a print friendly page click here INTRODUCTION Hazardous areas are those in which there exists a risk of explosion
More informationEtherCAT Box Modules (EPxxxx-xxxx)
Notes about operation of EtherCAT Box Modules (EPxxxx-xxxx) in potentially explosive areas (ATEX) Version: 1.1.0 Date: 2011-06-10 Table of Contents Table of Contents 1 Foreword 1 1.1 Notes on the documentation
More informationIS (Intrinsic safety) - Ex (Epsilon x) ATEX CENELEC
IS (Intrinsic safety) - Ex (Epsilon x) ATEX CENELEC By: Helge Knudsen, Test&Approval, Niros Telecommunication A/S You may have heard those expressions concerning Transceivers and other electric equipment
More informationATEX Safety Switches. More than safety.
ATEX Safety Switches More than safety. AUDIN - 8, avenue de la malle - 5370 Saint Brice Courcelles Tel : 03.6.0.0. - Fax : 03.6.0.8.0 - Web : http: www.audin.fr - Email : info@audin.fr ATEX products from
More informationTRI-SERVICE ELECTRICAL WORKING GROUP (TSEWG) 07/16/08 TSEWG TP-8: ELECTRICAL EQUIPMENT ENCLOSURES AND HAZARDOUS LOCATIONS
TSEWG TP-8: ELECTRICAL EQUIPMENT ENCLOSURES AND HAZARDOUS LOCATIONS ENCLOSURES. Select equipment enclosures to provide the following: To protect facility personnel from coming in contact with live parts.
More informationIntrinsically safe acoustic emission equipment opens the door to permanent monitoring applications in the oil and gas industry
18th World Conference on Nondestructive Testing, 16-20 April 2012, Durban, South Africa Intrinsically safe acoustic emission equipment opens the door to permanent monitoring applications in the oil and
More informationMany different instruments Many different operating principles including: May sample many different gases & vapour From relatively simple to complex
Part 2 Direct Reading Instrumentation Direct Reading Instruments Many different instruments Many different operating principles including: Electrochemical Photoionisation Flame ionisation Chemiluminescence
More informationFact Sheet No.2. CompEx Modules EX01 to EX04 for Gas and Vapour Environments
Fact Sheet No.2 CompEx Modules EX01 to EX04 for Gas and Vapour Environments Module Breakdown EX01: The preparation & installation of Ex d, n, e and p equipment in potentially explosive atmospheres. EX02:
More informationNON ELECTRICAL EQUIPMENT IN HAZARDOUS AREAS
NON ELECTRICAL EQUIPMENT IN HAZARDOUS AREAS The ATEX Directive consists of two EU Directives, ATEX Directive 2014/34/EU and ATEX Directive 99/92/EC. ATEX Directive 2014/34/EU embodies the European minimum
More informationHazardous Area Classifications and Protections
Hazardous Area Classifications Product Bulletin Hazardous Area Classifications and Protections The intent of this document is to provide a broad overview of hazardous area classifications and the types
More informationIECEx Certificate of Conformity
IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.:
More informationImplementation of ATEX Guidelines
Implementation of ATEX Guidelines Temperature and Climatic Test Chambers for Usage under Conditions Carrying a Risk of Fire and Explosion What are ATEX guidelines? Introduction Duties of the system user...
More informationCertificate of Compliance
FF0 001 Certificate of Compliance Certificate: 70116284 (LR 064969_0_00) Issued to: Mine Safety Appliances Company North American Division 1000 Cranberry Woods Dr Cranberry Township, Pennsylvania 16066-5296
More informationSmart encoders & actuators
Declaration of Conformity The manufacturer: LIKA ELECTRONIC SRL 36010 Carrè (VI) - Italy hereby declares that the following products (only when correctly assembled): XAC8018/1PB-14 XAC8018/1CB-14 XAC8018/1FD-14
More informationSwitches compliant with ATEX directive
Switches compliant with ATEX directive General Catalogue - Technical concepts page Position switches FD / FL series page 9 / Category Zone EPL Approvals 2G Gb Mb II 2G Ex ia IIC T6 Gb I Ex ia I Mb Product
More informationApproval of Ex (Electrical) Equipment for use/installation in Hazardous Areas.
Approval of Ex (Electrical) Equipment for use/installation in Hazardous Areas. Requirement under Rule 102 of the Petroleum Rules, 2002 lays down that no electrical wiring shall be installed and no electrical
More informationVSD AND SS DRIVING ATEX MOTORS February 2014
VSD AND SS DRIVING ATEX MOTORS February 2014 1 Introduction to ATEX 2 ATEX motor designation 3 VSD Sample Solutions 4 SS descriptions Introduction to ATEX EU territory define the use of electrical equipment
More informationTRASCO ATEX Couplings
TRASCO ATEX Couplings ATEX ANNEX GRM-CERT-EX-EN SIT S.p.A. Viale A. Volta, 2-20090 Cusago (MI) - Italy Tel. +39.02891441 Fax +39.0289144291 - info@sitspa.it www.sitspa.it ATEX Annex This Annex is an integral
More informationTechnical Data. General specifications Switching element function Rated operating distance s n 5 mm
0102 Model Number Features 5 mm flush Usable up to SIL 3 acc. to IEC 61508 Application Danger! In safety-related applications the sensor must be operated with a qualified fail safe interface from Pepperl+Fuchs,
More informationANNEX GD-CERT-EX-EN SIT
SITEX ATEX Couplings ATEX ANNEX GD-CERT-EX-EN SIT S.p.A. Viale A. Volta, 2-20090 Cusago (MI) - Italy Tel. +39.02891441 Fax +39.0289144291 - info@sitspa.it www.sitspa.com ATEX Annex This Annex is an integral
More informationPage 1 Copyright by the Fieldbus Foundation All rights reserved.
Page 1 Copyright by the Fieldbus Foundation 1996-2004.. FOUNDATION Fieldbus Application Guide 31,25 kbit/s Intrinsically Safe Systems AG-163 Revision 2.0 This application guide has been prepared to aid
More information4P75 CiTipeL Combustible Gas Sensor Part Number: PM
Product Datasheet 4P75 Document Purpose The purpose of this document is to present the performance specification of the 4P75 CiTipeL. This document should be used in conjunction with Operating Principles
More informationRE: USE OF FIREPRO IN POTENTIALLY EXPLOSIVE ATMOSPHERES
Limassol 20 th August, 2015 RE: USE OF FIREPRO IN POTENTIALLY EXPLOSIVE ATMOSPHERES This document is intended to provide clarification on the use of FirePro Condensed Aerosol Generators in Potential Explosive
More informationArea Classification and Types of Protection for Explosive Atmospheres: A Review
TELKOMNIKA Indonesian Journal of Electrical Engineering Vol. 16, No. 2, November 2015, pp. 238 ~ 243 DOI: 10.11591/telkomnika.v16i2.8506 238 Area Classification and Types of Protection for Explosive Atmospheres:
More informationGas Detection GAS BOOK.
Gas Detection GAS BOOK 3 Typical applications for portable gas detectors Confined spaces Confined spaces can be found in a myriad of industries and applications and are one of the most prevalent applications
More informationfor CE 134 CCSAUS certificate Meggitt SA Route de Moncor 4 PO Box 1616 CH Fribourg Switzerland Title page EN
Title page CCSAUS certificate: EN 70034691 for EX Meggitt SA Route de Moncor 4 PO Box 1616 CH - 1701 Fribourg Switzerland CCSAUS certificate 70034691 www.meggittsensingsystems.com www.vibro-meter.com THIS
More informationATEX Explained A brief Introduction
The Trusted Source for Secure Identity Solutions ATEX Explained A brief Introduction January 19, 2016 ATEX Zones Zones 1 (gas) or 21 (dust) (area in which under normal operation a potentially explosive
More informationAdditional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.
Additional Operating Instructions SITRANS F Vortex flowmeters Ex-d Edition 09/208 CONTENTS Safety instructions 3. General notes... 3.2 EU conformity... 3.3 Approval according to the IECEx scheme... 3.4
More informationNATIONAL RULES FOR ELECTRICAL INSTALLATIONS IN POTENTIALLY EXPLOSIVE ATMOSPHERES. ET 105:2001 (Second Edition)
NATIONAL RULES FOR ELECTRICAL INSTALLATIONS IN POTENTIALLY EXPLOSIVE ATMOSPHERES ET 105:2001 (Second Edition) Consolidated Amendments, Corrigenda and Errata 01/2010 Introduction When ET 105:2001 was originally
More informationIECEx Certificate of Conformity
IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate IECEx
More informationCertificate of Compliance
FF0 001 Certificate of Compliance Certificate: 70116279 (LR 025993_0_000) Issued to: General Monitors, Incorporated 26776 Simpatica Circle Lake Forest, California 92630 USA Attention: Larry Vlagea The
More informationSelecting a Safe Tank Gauging Product. Understanding Hazardous Area Definitions for Equipment Approvals
Selecting a Safe Tank Gauging Product Understanding Hazardous Area Definitions for Equipment Approvals Hazardous Area Approvals A Worldwide Requirement There are many environmental considerations within
More informationApparatus Groups are sometimes referred to, erroneously, as Gas Groups.
ATEX Jargon Buster ABB s ATEX jargon buster explains the terminology users are likely to encounter when purchasing equipment for hazardous areas. If you have a specific ATEX question, please send an email
More informationINSTRUCTION & SERVICE MANUAL
INSTRUCTION & SERVICE MANUAL D2xC1 ALARM HORN AND STROBE For Use In Hazardous Locations 3) Ratings and Markings 3.1 ATEX / IECEx certification The D2xC1 Alarm Horn and Strobe complies with the following
More informationPhoenix Explosion-proof. Pan & Tilt heads and Camera Housings for potentially exposed environments. Answers for infrastructure.
Phoenix Explosion-proof Pan & Tilt heads and Camera Housings for potentially exposed environments Answers for infrastructure. Video monitoring under extreme conditions Security Products from Siemens is
More informationTechnical Data. Dimensions
0102 Model Number Features 8 mm non-flush Stainless steel housing Usable up to SIL2 acc. to IEC 61508 Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 8 mm
More informationSchedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK
2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 17065:2012 to provide product conformity certification Newport Business Park New Port Road Ellesmere Port CH65 4LZ United Kingdom Contact:
More informationATM Lighting sp. z o.o
INSTALLATION AND MAINTENANCE MANUAL FOR EXPLOSIONPROOF LIGHT FITTING EXL390LED Carefully read the instructions before mounting the light fitting. ATM Lighting sp. z o.o., ul. Budowlanych 31, 80-298 Gdańsk,
More informationManual Power relay SR853
Manual Power relay SR853 Product types SR853.8.x.x, Rev. 1 SR853 manual page2 The symbols WARNING, CAUTION, NOTE This symbol warns of a serious hazard. Failure to observe this warning may result in death
More informationManual. WAGO-I/O-SYSTEM 750 Use in Hazardous Environments 750-xxx Definition of Terms, Marking and Installation Regulations. Version 1.0.
WAGO-I/O-SYSTEM 750 Use in Hazardous Environments 750-xxx Definition of Terms, Marking and Installation Regulations 2 General WAGO-I/O-SYSTEM 750 General 2010 by WAGO Kontakttechnik GmbH & Co. KG All rights
More informationTraining, Assessment, Consultants for Hazardous & Industrial Areas
Training, Assessment, Consultants for Hazardous & Industrial Areas EPIT provides specialist training, assessment and consultancy services for engineers working in hazardous and industrial environments.
More informationmanual addendum DELPHI Ex
manual addendum DELPHI Ex II 2G Ex eb IIC T4 Gb II 2D Ex tb IIIC T135 C IP65 Db Tamb=-20 +40 C Reference list: Norm (last issue) Title Dir. 2014/34/UE EN 60079-31 EN60079-0 EN60079-7 Equipment and Protective
More information