1 Alarm Panel USER MANUAL [ PRELIMINARY HARDWARE MANUAL ] Visit our website at for the latest PDF manual and FAQs. May 7, 2008 D-OC-UM v1.0a

2 Revision History April 28, 2008 May 7, 2008 Created document. Initial release as preliminary hardware manual. This document contains proprietary information which is protected by copyright. All rights are reserved. No part of this document may be photocopied without prior written consent of DPS Telecom. All software and manuals are copyrighted by DPS Telecom. Said software and manuals may not be reproduced, copied, transmitted or used to make a derivative work, by either mechanical, electronic or any other means in whole or in part, without prior written consent from DPS Telecom, except as required by United States copyright laws DPS Telecom Notice The material in this manual is for information purposes and is subject to change without notice. DPS Telecom shall not be liable for errors contained herein or consequential damages in connection with the furnishing, performance, or use of this manual.

3 Contents Visit our website at for the latest PDF manual and FAQs 1 Overview Summary of Features Description 1 2 Shipping List 1 3 Specifications 3 4 Hardware Hardware Installation Overview Tools Needed Mounting Power Connection LAN Connection Alarm Connections LEDs Front Panel Back Panel Buttons Speaker 15 5 Unit Configuration Craft Port TTY Interface Menu Shortcut Keys Ethernet Port Setup 18 6 Operation EMI Mode Windows Software 7 Updating Firmware FTP Method Craft Port (Serial) 25 8 Technical Support 26

4

5 1 1 Overview 1.1 Summary of Features Able to monitor four alarms with four dry-contact inputs for Critical, Major, Minor and Power alarms. Forward controls associated with dry-contact alarms with four dry-contact output relays. Able to echo Major and Minor discrete inputs to outputs. Dual power source makes sure that the unit is always powered up. Built in SNMPv1 Agent can be controlled from any SNMP Manager. 1.2 Description The Alarm Panel allows the user to monitor for certain conditions and is notified remotely via SNMPv1 or locally with blinking LEDs and distinct beeping patterns. 2 Shipping List While unpacking the Alarm Panel, please make sure that all of the following items are included. If some parts are missing, or if you ever need to order new parts, please refer to the part numbers listed and call DPS Telecom at (800) Alarm Panel D-PR-RSPV Alarm Panel User Manual D-OC-UM Alarm Panel Resource CD (includes manuals, MIBs and software) Two WAGO 2-pin Connectors for Main Power Two 3/4-Amp GMT Main Power Fuses

6 2 Twelve 3/8" Ear Screws DB9M-DB9F Download Cable 6 ft. D-PR A-04 Two Red Power Cables with #10 stud hole ring Two Black Power Cables with #10 stud hole ring terminal to open end. 6 ft. terminal to open end. 6ft. D-PR A-06 D-PR A-06 One Green ground cable with #10 stud hole ring terminal to 1/4" stud hole ring terminal. 18 inches. D-PR A-02

7 3 3 Specifications Dimensions: 1.72 H x 17 W x 29.3 D Mounting: HP slide rack mounting. Nominal Voltage: -48VDC / -60VDC Operating Voltage: -36 to -72 VDC Current draw: 200mA at -48VDC (May vary depending on input voltage) Fuse: 2 GMT 3/4 AMP Interface: 1 RJ45 10/100 Ethernet Port 2 DB-9 RS232 Craft Ports (One in front, one in back) 2 DB-15 Connectors (Telco Alarm input/output) Visual Interface: 12 Large unicolor LEDs (on front) 15 Small unicolor LEDs (7 on front, and 8 on back) Audible: Piezo speaker Push Buttons: 1 ACK switch (on front) 1 Reset switch (hidden on front) Relay Outputs: 1A, or 30W/30VA when closed Operating Temperature: 0 to +60 degrees Celsius (+32 to +140 degrees Fahrenheit) Non-Operating Temperature: -40 to +70 degrees Celsius (-40 to +158 degrees Fahrenheit) Operating Humidity: 5% to 95% relative humidity, non-condensing, both operating and non-operating

8 4 4 Hardware 4.1 Hardware Installation Overview Follow this order of steps when installing your Alarm Panel. Detailed instructions for each step are given in the following sections. 1. Unpack the Alarm Panel and check parts. Please see the shipping list to verify that all parts were included in your shipment. 2. Connect power leads to the Alarm Panel. 3. Connect communication lines to the Alarm Panel. The Alarm Panel has a LAN connection for SNMP and Web browser access. 4. Connect alarm inputs. 5. Connect alarm outputs. 6. Connect to the Alarm Panel. You can connect to the Alarm Panel through either the front or back panel craft ports at baud. 7. Provision the Alarm Panel. 4.2 Tools Needed Tools needed: Phillips screwdriver Small standard No.2 screwdriver (1/16" for screw-lug connectors) Wire strippers/cutter PC with terminal emulation software

9 5 4.3 Mounting Fig. 4.3a - Location of mounting screws Use the included 3/8" ear screws to attach a rack mount to both sides of the Alarm Panel unit. Each side of the unit has 6 slots for screws. Two near the front and 4 along the edge. See Fig. 4.3a for screw locations.

10 6 4.4 Power Connection The Alarm Panel has two screw terminal barrier plug power connectors, located on the left and right side of the back panel. WARNING! The Grounding Lug on the back of the unit provides a permanent connection to earth ground when connected. The Grounding Lug must be used in order to comply with certification standards.... Fig. 4.4a - Power A and Power B Before you connect a power supply to the Alarm Panel unit, test the voltage of your power supply: Connect the black common lead of a voltmeter to the ground terminal of the battery, and connect the red lead of the voltmeter to the battery's 48VDC / -60VDC terminal. The voltmeter should read between 36 and 72 VDC. If the reading is outside this range, test the power supply. To connect the Alarm Panel to a power supply, follow these steps: 1. Remove Fuse A and Fuse B from the back panel of the Alarm Panel. Do not reinsert the fuses until all connections to the unit have been made. 2. Use the grounding lug to connect the unit to earth ground. The grounding lug is next to the symbol. Insert the 1/4" eyelet of the earth ground cable (included green cable) between the two bolts on the grounding lug. Connect the other of the earth ground cable to a ground terminal. See Fig. 4.4b. Fig. 4.4b - Grounding Lug 3. Remove the WAGO power connector.

11 7 4. Using the cables provided, insert the battery ground (included black cable) into the WAGO connector's right terminal; then insert the 48VDC / -60VDC line (included red cable) to the connector's left terminal. The wire opening is spring loaded. Push down as shown in Fig 4.4c to allow the wire into the opening. Fig. 4.4c - WAGO 2 pin connector 5. Push the power connector plug firmly back into the barrier plug. Note that the connector can be inserted into the plug only one way this ensures that the connector can only be reinserted with the correct polarity. 6. Repeat Steps 2 5 for Power Connector B. 7. Reinsert Fuse A and Fuse B to power the Alarm Panel unit. If the power feed is connected correctly, the LEDs by the connectors will light GREEN. The LED by the power connector will be off if the power feed is reversed or if a fuse is not inserted.

12 8 4.5 LAN Connection Fig. 4.5a - LAN connection on back panel The Alarm Panel's LAN connection is used for many functions: SNMP and Web browser access, provisioning, firmware download, monitoring and control. Connect a standard RJ45 Ethernet cable from your local area network (LAN) to the 10/100 Ethernet jack on the back of the Alarm Panel. RJ45 Ethernet Connection Receive In (RI ) Receive In + (RI+) Transmit Out (TO ) Transmit Out + (TO+)

13 9 4.6 Alarm Connections The Alarm Panel's discrete alarm inputs and alarm outputs are connected through the 15-pin connectors labeled "Alarm In" and "Alarm Out" on the unit's back panel. Fig. 4.6a - Alarm In and Alarm Out connections

14 10 DB15 - Alarm In Alarm In Pin # Direction Type Description 1 Output Discrete Minor Reset + 2 Output Discrete Minor Reset - 3 Output Discrete Major Reset + 4 Output Discrete Major Reset - 5 Input Critical Alarm + 6 Not Used 7 Input Critical Alarm - 8 Input Minor Alarm + 9 Vol = 0V to 3.3V Voh = 3.3V to 72V DC, 20mA Tolerates 0 to 48VDC continuous, up to 60VDC at 50% duty cycle, up to 72VDC at 30% duty cycle, sinks 12mA max. Not Used 10 Input Minor Alarm - 11 Input Major Alarm + 12 Not Used 13 Input Major Alarm - 14 Input Power Alarm + 15 Input Power Alarm - Shield Signal Level Shelf Ground N/A

15 11 DB15 - Alarm Out Alarm Out Pin # Direction Type Description 1 Input Discrete Minor Reset + 2 Input Discrete Minor Reset - 3 Input Discrete Major Reset + 4 Input Discrete Major Reset - 5 Output Critical Alarm NO 6 Output Critical Alarm NC 7 Output Critical Alarm - COM 8 Output Minor Alarm - NO 9 Output Minor Alarm NC 10 Output Minor Alarm COM 11 Output Major Alarm - NO 12 Output Major Alarm NC 13 Output Major Alarm COM 14 Output Power Alarm NO 15 Output Power Alarm - COM Shield NO = Normally Open NC = Normally Closed COM = Common Shelf Ground Signal Level Tolerates 0 to 48VDC continuous, up to 60VDC at 50% duty cycle, up to 72VDC at 30% duty cycle, sinks 12mA max Contacts withstand 72V DC when open, and are rated for 1A or 30W/30VA when closed. N/A

16 LEDs Front Panel Fig. 4.7a - Front Panel LEDs and communication status LED STATUS Craft TX Blink Green Craft port transmit activity. Data sent out craft port. Craft RX Blink Green Craft port receive activity. Data received on craft port. CRITICAL Blink Red The unit has an un-acknowledged critical alarm. Solid Red The unit has an acknowledged critical alarm. Off MAJOR The unit has an un-acknowledged major alarm. Solid Red The unit has an acknowledged major alarm. No major alarm. Blink Yellow The unit has an un-acknowledged minor alarm. Solid Yellow The unit has an acknowledged minor alarm. Off POWER No critical alarm. Blink Red Off MINOR DESCRIPTION No minor alarm. Blink Yellow The unit has an un-acknowledged power alarm. Solid Yellow The unit has an acknowledged power alarm. Off No power alarm. LAN TX Blink Green LAN transmit activity. Data sent over LAN connection. LAN RX Blink Green LAN receive activity. Data received from LAN connection. Solid Yellow Unit has lost communications with the SNMP manager. COM Fail Light Bulb Off Normal operation. Communication is working ok. Solid Green Internal Power OK. Indicates good internal power. Off Solid Yellow Warning Sign Off Problem with internal power. Check input feeds. Internal Error detected. Normal operation.

17 Back Panel Fig a - Back panel LEDs LED STATUS DESCRIPTION Power B Solid Green Fuse B Solid Red LAN LNK Solid Green LAN connected. Indicates that there is an Ethernet connection. LAN ACT Blink Green LAN Activity. Indicates that data is being transferred through the LAN connection. CRAFT TX Blink Green Craft activity. Indicates that data is being transmitted out the craft port. CRAFT RX Blink Green Craft activity. Indicates that data is being received on the craft port. Fuse A Solid Red Fuse in Fuse A has blown. Power A will not be used to power the unit until the fuse has been replaced. Power A Solid Green Good power from Power A. Fuse and power must be inserted for LED to light. Good power from Power B. Fuse and power must be inserted for LED to light. Fuse in Fuse B has blown. Power B will not be used to power the unit until the fuse has been replaced.

18 Buttons Fig. 4.8a - Reset and ACK buttons The front panel has two buttons. One small button for reset and a button for ACK (acknowledge alarms). These buttons perform three different functions: Acknowledge alarm. Alarms can be acknowledged by pressing the ACK button located near the speaker. Pressing the ACK button will stop audible alarms and will cause the large Critical, Major, Minor, and Power LEDs to stop blinking until another alarm is received or cleared. The ACK button will not clear alarms. Reset the unit. The Alarm Panel has a hardware reset button that can be accessed through a small hole near the speaker. A small pin, like a bent paper clip, is required to reach the reset button. Reset Provisioning. Provisioning can be restored back to the factory defaults by using both the reset button and the ACK button. The reset button provides a hard reset to the processor. Once the reset button is released, the processor will boot-up. During the boot-up, the processor will sample the ACK switch within about 20 seconds of the reset button being depressed. If the processor detects the pressed ACK switch during boot-up, the stored provisioning will be permanently reset until re-provisioned. To reset the provisioning, perform the following steps: 1. Use a bent paper clip to press and hold the reset button. 2. Press the ACK switch while holding in reset. 3. While keeping the ACK switch pressed, depress reset. 4. Continuously hold the ACK switch for about 20 seconds, or until the front LEDs begin to flash.

19 Speaker The internal speaker can be found on the front panel. The speaker will generate a beeping pattern when an alarm comes in until it clears or is acknowledged. The sound generated will always be for the alarm with the highest severity level with Critical being the highest and Power being the lowest. Alarm Level Speaker Pattern Critical Two short beeps followed by a pause. Major One beep followed by a pause. Minor Beeps for five seconds, then stops. Power Continuous tone. Note: Pressing the ACK button will silence the speaker until another alarm occurs.

20 16 5 Unit Configuration 5.1 Craft Port To make a local connection to the Alarm Panel, use the provided DB9M-DB9F cable to connect the COM port of your PC to the front or back panel craft port of the unit. Fig. 5.1a - Com port settings Select the following COM port options: Bits per second: Data bits: 8 Parity: None Stop bits: 1 Flow control: None Hot Tip! It is extremely important to set Flow Control to None. Flow control normally defaults to hardware in most terminal programs and this may not work correctly with the Alarm Panel. When a connection is established, press ESC to access the configuration menu.

21 TTY Interface The TTY interface is the Alarm Panel's built-in provision controls for basic configuration. Configure the Alarm Panel's Ethernet port settings, monitor the status of input alarms, operate control relay outputs, or control LEDs and audible. To use the TTY interface with the Alarm panel, all you need is a PC with terminal emulation software (i.e. Hyperterminal) and a serial connection to the Alarm Panel. Connect to the Alarm Panel via Craft Port on the front or back panel. Follow the settings provided in Section 5.1 (Craft Port). When the connection has been established, press ESC to bring up the TTY menu. The unit may already be responding by sending "U" before pressing ESC. If the menu does not show up, make sure the connection's baud rate is set to Make sure the craft port connection is firmly in place. Press any key in Hyperterminal and make sure the Craft Port RX LED blinks green. This means that the Alarm Panel is receiving data. Also check if the Craft Port TX LED is blinking green. This means that the Alarm Panel is sending data that should be displayed to the screen Menu Shortcut Keys The letters before or enclosed in parentheses ( ) are menu hotkeys. Press the hotkey to select the option. Pressing the ESC key will always bring you back to the previous level. Hotkeys are not case sensitive. Fig a - TTY Main Menu Stats will display system statistics and info. RAM will run tests on the unit's SRAM memory. LED will run tests for the processor controlled LEDs. Switch will test the ACK button and the internal DIP switches to make sure the buttons/switches are being read properly. Inputs will test the Alarm In port. Outputs will test the Alarm Out port. Speaker will test the speaker. Ethernet will display current Ethernet settings and will configure the IP address. This will also initialize the LAN connection. NVRam will run a test on the unit's non-volatile memory by writing to it and reading back test patterns. RTC will test the internal real time clock and can be used to test the RTC battery. Analogs will display the current voltage readings from Power A and Power B. Advance contains more advance tests not normally required for Production units. Reboot will reboot the unit.

22 Ethernet Port Setup In order to access the Alarm Panel via LAN, the unit must be assigned an IP address. Follow the instructions below to configure the Alarm Panel's static IP address. From the top most menu, press "E" for Ethernet. The current NET interface settings should be displayed with a sub-menu for IPA and PING. Fig a - Ethernet Menu Press "I" for IPA. You should now be prompted to enter an new IP address. Enter the new IP address and press Enter.

23 19 Fig b - Entering the IP address The new IP address should now display back onto the terminal screen.

24 20 6 Operation A windows utility can monitor the Alarm Panel while it is in EMI mode. This is used to test the unit's LEDs, audible sounds and alarm in and out. 6.1 EMI Mode If DIP switch 1 is on, the unit should automatically startup in EMI mode. The front LEDs will blink one at a time and cycle from left to right. When the last LED blinks, it will light up all LEDs before going back to the first LED. If the LEDs are not cycling, connect to the unit's TTY interface at baud and check if DIP switch 1 is on (press "W" for s(w)itch then DIP). If it's already ON, power cycle the alarm panel and it should start up in EMI mode. If it's OFF, open the unit and switch DIP into the ON position. EMI mode can also be enabled without using DIP switch 1. This can be done through the TTY interface (see section 5.1 and 5.2). From the TTY interface's top most menu (should have entries for S)tatus R)AM F)lash L)ED...) press "D" for advance then "E" for EMI. Ethernet settings may need to be setup prior to running EMI mode if DIP switch 1 is in the OFF position. Make sure the Alarm Panel has the proper connections. This setup requires a LAN connection to a PC with HWDiagW software utility installed and a loopback cable that would tie Alarm In with Alarm Out. See Fig. 6.1a. Fig. 6.1a - Overview of connections for EMI mode Use the provided loopback cable for Alarm In and Alarm Out. The end for Alarm In and Alarm Out should be labeled differently. This will enable the windows software to verify that both Alarm In and Alarm Out are working properly. Output relays will cycle one at a time from 1 to 6, and in groups when in EMI mode. Note: The loopback cable does not normally ship with the Alarm Panel.

25 21 Make sure the unit has a LAN cable connected to the LAN connector on the back of the unit and that the green LED for LNK is solid green. Define the unit's IP address. See section If the unit is in EMI mode, press ESC twice on the TTY interface to display the menu. Define the IP Address and press ESC. Put the unit back into EMI mode by pressing "D" for advance then "E" to enter EMI mode. If DIP switch 1 is on, power cycling the unit will also cause it to start up in EMI mode.

26 Windows Software Install HWDiagW on a Windows machine. This can be found in the Alarm Panel Resource disk. This will allow monitoring of EMI mode data from the Alarm Panel. Make sure you can ping the Alarm Panel from the PC from where the software is installed. Start HWDiagW by clicking on the HWDiagW icon on your desktop or under Programs->DPSTelecom>HWDiagW. Set the program's communication settings for the Alarm Panel by clicking on File -> Settings. Fig a - File menu Go down to the IP Address field and enter the IP address of the Alarm Panel. Port should be set to 2001, DCP Addr should be set to 1. Poll Delay is configurable and will affect how often HWDiagW will retrieve data from the Alarm Panel. Fig b - Communication Settings Press the Save button to save the settings then click on the Start button on the main interface. An indicator next to "Status" will rotate when the program is running.

27 23 If the loopback cable is inserted properly, points 1 to 6 should display a dot one at a time and in groups. The dot indicates that the unit was able to read the alarm condition from the output relays which should be cycling while in EMI mode. Point 9 would also have a dot to indicate that DIP switch 1 is in the ON position. Fig c - HWDiagW interface The program will display when Alarms 1-6 are set, when DIP switches 1-4 are on, when the ACK switch is pressed, and the analog values for Power A and Power B. It also displays the status of the connection between the application and the Alarm Panel and how many polls it has successfully completed.

28 24 7 Updating Firmware New firmware can be loaded to the unit via FTP or serially via ComloaderW. New firmware and ComLoaderW (software for Windows PC) can be found at FTP Method If the Alarm Panel is accessible on the network, then new firmware can be sent to the unit via FTP. To update firmware via FTP, follow these steps: 1. Start an FTP session with a command-line based ftp client. If using Microsoft Windows or MS-DOS, open a command terminal and enter "FTP". This will initiate an ftp session. 2. Enter "Open XXX.XXX.XXX.XXX" with the IP of the unit in place of the X's. A message should appear indicating the connection was made and will ask for a user. 3. Enter a User name and press enter. If it's a valid user, it will now ask for a password. 4. Enter the password. If the login was accepted, it should say "User logged in". 5. Type in "bin" to switch to binary mode. Press enter. 6. Type in "put XXXXX.tsk" with the firmware filename in place of the X's. 7. If the new firmware sent ok, type in "literal REBT" and press enter. This is case sensitive. "literal" should be in lowercase and "REBT" should be all uppercase. 8. Type "bye" to end the FTP session and reboot the Alarm Panel with the new firmware. Note: DPS also provides a script batch file, on the Resource CD which ships with the unit, to help automate the FTP process. Fig. 7.1a shows a sample session using command line in Windows. Fig. 7.1a - Sample FTP session to Alarm Panel

29 Craft Port (Serial) Fig. 7.2a - ComLoaderW for Windows PC To update the Alarm Panel's firmware using ComloaderW, follow these steps: 1. Power the Alarm Panel. 2. Connect the DB9 connector of a DB9M-to-DB9F cable to the COM port of your PC. 3. Insert one of the cable's DB9 plug into the craft port on the front panel or rear panel of the Alarm Panel. 4. Select the COM port of your PC by clicking the "COM Port Settings" button. This will open the Communications Settings dialog box, where you can select communications and flow control settings. Select baud. 5. Select a task file by typing its path name in the Task File box, or browse to the file by clicking the button. 6. Reboot the Alarm Panel and quickly click the Start button. You may reboot by either cycling power or by pressing the reset switch on the front of the unit. The firmware upgrade will be automatically uploaded to the unit. While uploading, the ComloaderW screen will display the checksum, type, and phase of the task file and the baud rate of your connection to the Alarm Panel. The progress bar indicates the progress and completion of the firmware upload. The Open Protocol button opens the Protocol screen. The Protocol screen is for troubleshooting purpose only. Do not open the Protocol screen unless you are requested to do so by DPS Telecom Technical Support Personnel. If you wish to abort the firmware upload, click the Abort button. Once the firmware upload is finished, click the Exit button to exit ComloaderW.

30 26 8 Technical Support DPS Telecom products are backed by our courteous, friendly Technical Support representatives, who will give you the best in fast and accurate customer service. To help us help you better, please take the following steps before calling Technical Support: 1. Check the DPS Telecom website. You will find answers to many common questions on the DPS Telecom website, at Look here first for a fast solution to your problem. 2. Prepare relevant information. Having important information about your DPS Telecom product in hand when you call will greatly reduce the time it takes to answer your questions. If you do not have all of the information when you call, our Technical Support representatives can assist you in gathering it. Please write the information down for easy access. Please have your user manual and and hardware serial number ready. 3. Have access to troubled equipment. Please be at or near your equipment when you call DPS Telecom Technical Support. This will help us solve your problem more efficiently. 4. Call during Customer Support hours. Customer support hours are Monday through Friday, from 7 A.M. to 6 P.M., Pacific time. The DPS Telecom Technical Support phone number is (559) Emergency Assistance: Emergency assistance is available 24 hours a day, 7 days a week. For emergency assistance after hours, allow the phone to ring until it is answered with a paging message. You will be asked to enter your phone number. An on-call technical will return your call as soon as possible.

31 27 Notes

32 Dependable, Powerful Solutions that allow users to monitor larger, more complicated networks with a smaller, less trained staff Your Partners in Network Alarm Management E Yale Fresno, CA fax

Quick Alert Remote (QA216R)

Quick Alert Remote (QA216R) Quick Alert Remote (QA216R) Description The QA 216 Remote is used by AT&T to monitor tower lights and turned down facilities. It is a 16-bit alarm unit used to transport discrete alarms from a remote location

More information

Remote Power Switch (DC)

Remote Power Switch (DC) Remote Power Switch (DC) USER MANUAL Visit our website at www.dpstelecom.com for the latest PDF manual and FAQs. November 0, 207 D-UM-26RP-200 Firmware Version.0J.083 Revision History November 0, 207 Added

More information

Added password for IP setup page : Password must be in IP format!

Added password for IP setup page : Password must be in IP format! NETWORK POWER MONITOR Release : 21 August 2014 Hardware Version : Version 7 Firmware version 1.00 PC Application Software : Version (latest)...2 Added password for IP setup page : Password must be in IP

More information

NetGuardian BSM and BSM-G2

NetGuardian BSM and BSM-G2 NetGuardian BSM and BSM-G2 USER MANUAL D-PK-NGBSM Visit our website at www.dpstelecom.com for the latest PDF manual and FAQs. July 10, 2018 D-UM-NGBSM Firmware Version 2.0A Revision History July 10, 2018

More information

GPS Evaluation Kit EVA1037/1080

GPS Evaluation Kit EVA1037/1080 GPS Evaluation Kit An evaluation system for Tyco Electronics GPS modules A1037-A & A1080-A User s Manual Version 2.0 Hardware Revision 01 This page was intentionally left blank. Revision History Revision

More information

User Manual DPM 208. Alarm and Control Network Element. Um119889

User Manual DPM 208. Alarm and Control Network Element. Um119889 User Manual DPM 208 Alarm and Control Network Element Um119889 DPM 208 Version 1.0B Alarm and Control Network Element Publication Number UM119889 Date of issue: 8-31-99 4955 E. Yale Ave. Fresno, CA 93727

More information

NetGuardian V16/M16 G2

NetGuardian V16/M16 G2 NetGuardian V6/M6 G2 USER MANUAL D-PK-26V2 D-PK-M6G2 D-PK-C6V2 Visit our website at www.dpstelecom.com for the latest PDF manual and FAQs. September 26, 206 D-UM-26V2 Firmware Version.0S Revision History

More information

NetGuardian. and other RTUs

NetGuardian. and other RTUs NetGuardian and other RTUs 2 Factory Training Workbook NetGuardian Contents The NetGuardian 832A G5 NGEdit Software NetGuardian Hardware NetGuardian Setup NetGuardian Provisioning and Monitoring Troubleshooting

More information

PWM. Solar Charge controller with Ethernet. Solar Smart PWM 20Amp. Hardware Description : Release : 19 June 2014

PWM. Solar Charge controller with Ethernet. Solar Smart PWM 20Amp. Hardware Description : Release : 19 June 2014 Solar Charge controller with Ethernet Release : 19 June 2014 Hardware Version : Version 1 Firmware version 1 PC Application Software : Version 1.0.0.0 Hardware Description : The Solar Smart regulator was

More information

Discrete Point Module (DPM) 216 G2

Discrete Point Module (DPM) 216 G2 Discrete Point Module (DPM) 26 G2 USER MANUAL Visit our website at www.dpstelecom.com for the latest PDF manual and FAQs. December 8, 200 D-OC-UM0C.800 Firmware Version.0A Revision History May 27, 20 Misc

More information

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge Replaceable LED modules 11 Alarm Sequences as per ISA-18.1 standard Each channel/window fully field programmable RS232 or RS485 MODBUS-RTU communication Repeat relay for each window and multifunction relays

More information

Installation Manual. ATS Remote Annunciator Catalog 5350 DANGER WARNING D

Installation Manual. ATS Remote Annunciator Catalog 5350 DANGER WARNING D ASCO 5350 The ASCO 5350 ATS Remote Annunciator is listed under the Underwriter s Laboratories Standard UL-1008 for Automatic Transfer Switch accessories. This stand-alone device provides individual status

More information

NetGuardian 480/432 G3 & G4

NetGuardian 480/432 G3 & G4 NetGuardian 480/432 G3 & G4 USER MANUAL D-PK-NG480 D-PK-NG432 Visit our website at www.dpstelecom.com for the latest PDF manual and FAQs. October 28, 206 D-UM-NG480/NG432 Firmware Version 2.0N Revision

More information

NetGuardian LPG Controller

NetGuardian LPG Controller NetGuardian LPG Controller USER MANUAL D-PK-NGLPG Visit our website at www.dpstelecom.com for the latest PDF manual and FAQs. June 3, 205 D-UM-NGLPG Firmware Version.0A Revision History June 3, 205 Initial

More information

DPM & DPM-216 USER MANUAL. May 21, Firmware Version - DPM: 2.1I Firmware Version - DPM216: 1.0A D-OC-UM

DPM & DPM-216 USER MANUAL. May 21, Firmware Version - DPM: 2.1I Firmware Version - DPM216: 1.0A D-OC-UM DPM & DPM-216 USER MANUAL May 21, 2009 D-OC-UM09.521200 Firmware Version - DPM: 2.1I Firmware Version - DPM216: 1.0A Revision History May 21, 2009 Released updated D-OC-UM09.521200 March 12, 2009 Released

More information

NetGuardian 480 G4 USER MANUAL. Visit our website at for the latest PDF manual and FAQs.

NetGuardian 480 G4 USER MANUAL. Visit our website at  for the latest PDF manual and FAQs. NetGuardian 480 G4 USER MANUAL Visit our website at www.dpstelecom.com for the latest PDF manual and FAQs. June 2, 203 D-UM-NG480 Firmware Version.F Revision History June 2, 203 Initial Release This document

More information

Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE

Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE General Description This guide provides a summary for installing and configuring the Centaur TM Cube Slave Alarm Signalling Equipment

More information

Ethernet General Purpose

Ethernet General Purpose Ethernet General Purpose Technical Manual Revision 1.03 8 November 2013 Pakton Technologies IO PAE224 Ethernet GPIO Manual.docx Page 1 of 22 Revision 1.03 Last updated 8/11/2013 Table of Contents INTRODUCTION...3

More information

Revision November 2013 JVA Technologies. Ethernet General Purpose IO Technical Manual

Revision November 2013 JVA Technologies. Ethernet General Purpose IO Technical Manual Revision 1.03 8 November 2013 JVA Technologies Ethernet General Purpose IO Technical Manual www.jva-fence.com.au Table of Contents INTRODUCTION...3 Scope and Purpose...3 Glossary...3 SPECIFICATIONS...4

More information

Alarm Client. Installation and User Guide. NEC NEC Corporation. May 2009 NDA-30364, Revision 9

Alarm Client. Installation and User Guide. NEC NEC Corporation. May 2009 NDA-30364, Revision 9 Alarm Client Installation and User Guide NEC NEC Corporation May 2009 NDA-30364, Revision 9 Liability Disclaimer NEC Corporation reserves the right to change the specifications, functions, or features,

More information

NetGuardian 216 G3 USER MANUAL. Visit our website at for the latest PDF manual and FAQs.

NetGuardian 216 G3 USER MANUAL. Visit our website at  for the latest PDF manual and FAQs. NetGuardian 26 G3 USER MANUAL Visit our website at www.dpstelecom.com for the latest PDF manual and FAQs. February 9, 202 D-UM-NG26-200 Firmware Version 2.0K Revision History February 9, 202 Added Verizon

More information

UNC100 Integra Manual

UNC100 Integra Manual UNC100 Integra Manual New Generation Building Security July 30, 2014 V1.2 Copyright Notice Copyright 1995-2014 by All rights reserved Worldwide. Printed in Canada. This publication has been provided pursuant

More information

OPERATOR S MANUAL MODEL AP15/AP15-1/AP15-2 PC-ALARM PANEL

OPERATOR S MANUAL MODEL AP15/AP15-1/AP15-2 PC-ALARM PANEL ap15_2manual04/22/13 Page 1 4/22/2013 1 Serial Number : Option: OPERATOR S MANUAL MODEL AP15/AP15-1/AP15-2 PC-ALARM PANEL Micro Seven, Inc. 1095-K N.E. 25th Hillsboro, OR 97124 U.S.A. phone: 503-693-6982

More information

Dry Contact Probe DCP (#30008)

Dry Contact Probe DCP (#30008) Dry Contact Probe DCP (#30008) The Networked Robotics DCP probe enables network data collection of the state of any normally open or normally closed switch. This product can sense alarm contact outputs

More information

Ion Gateway Cellular Gateway and Wireless Sensors

Ion Gateway Cellular Gateway and Wireless Sensors Page 1 of 9 Account & Network Setup If this is your first time using the Ion Gateway online system site you will need to create a new account. If you have already created an account you can skip to the

More information

Instruction manual MTL process alarm equipment. October 2016 CSM 725B rev 2 MTL RTK 725B. Configuration Software Manual

Instruction manual MTL process alarm equipment. October 2016 CSM 725B rev 2 MTL RTK 725B. Configuration Software Manual Instruction manual MTL process alarm equipment October 2016 CSM 725B rev 2 MTL RTK 725B Configuration Software Manual SECTION 1 - INTRODUCTION... 5 Basic Requirements... 5 SECTION 2 - SOFTWARE INSTALLATION...

More information

User Manual. Dryer Controller M720

User Manual. Dryer Controller M720 User Manual Dryer Controller M720 Hardware version 1.00 Software version 1.00 Preliminary version Manual M720 Dryer controller Page 1 of 42 Document history Preliminary version: - Created in April, 2009

More information

Laptop / PC Programming Manual

Laptop / PC Programming Manual Laptop / PC Programming Manual Doc. # Fire PC Program rev B 01.07 This Document is property of Evax Systems, Inc. The Evax Fire Solutions Programmer Components 2 1.0 System Setup 4 1.1 Interface Setup

More information

Manual# User s Manual. 200E Series. DCU 210E/208E Diesel Engine Control Unit RP 210E Remote Panel

Manual# User s Manual. 200E Series. DCU 210E/208E Diesel Engine Control Unit RP 210E Remote Panel Manual# 1006494 User s Manual 200E Series DCU 210E/208E Diesel Engine Control Unit RP 210E Remote Panel User's Manual Rev. 1.0 Marine Pro 200E Series ~~~ DCU 210E Diesel Engine Control Unit DCU 208E Diesel

More information

T4000 Security Communicator

T4000 Security Communicator Inner Range T4000 Security Communicator 1 T4000 Security Communicator by Inner Range P/N: 998530 / 998530NZ 998530LT (Lite Version) Installation & Operation Manual. Rev: 1.5 Inner Range Pty. Ltd. www.innerrange.com

More information

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers. ModSync Sequencing System Installation & Operation Manual For use with Fulton Steam Boilers. Revision 3.0 8/21/2008 - 2 - Table of Contents Introduction Page 4 Features Page 4 Sequence of Operation Page

More information

IRIS Touch Firmware Enhancements and Additions from Version to Version

IRIS Touch Firmware Enhancements and Additions from Version to Version Overview IRIS Touch Firmware Enhancements and Additions from Version 1.14.3 to Version 1.19.1 This document details enhancements to the feature set of the IRIS Touch from firmware Version 1.14.3 to Version

More information

Dryer Controller M720

Dryer Controller M720 User Manual Dryer Controller M720 Hardware version 2.00 Software version 2.00 Manual M720 Dryer controller Page 1 of 60 Document history Preliminary version: - Created in April, 2009 Hardware Version 2.00,

More information

Installation Manual COPYRIGHT NOTICE

Installation Manual COPYRIGHT NOTICE Installation Manual COPYRIGHT NOTICE Copyright 2007 by Quest Controls Inc (QUEST). The material discussed in this publication is the proprietary property of QUEST. QUEST retains all rights to reproduction

More information

ibox Modbus Server Gateway for the integration of Notifier ID3000 / ID3002 / ID60 / ID50 fire panels in Modbus enabled monitoring and control systems

ibox Modbus Server Gateway for the integration of Notifier ID3000 / ID3002 / ID60 / ID50 fire panels in Modbus enabled monitoring and control systems Honeywell Life Safety Iberia C/Pau Vila 15-19; 08911 Badalona Barcelona T. 902 03 05 45; Internacional:+34932424236 www.honeywelllifesafety.es infohlsiberia@honeywell.com ibox Modbus Server Gateway for

More information

RF SCOUT PLUS INSTRUCTION MANUAL. Dielectric, LLC 22 Tower Rd. Raymond, ME Phone: January 2015, Rev B 1

RF SCOUT PLUS INSTRUCTION MANUAL. Dielectric, LLC 22 Tower Rd. Raymond, ME Phone: January 2015, Rev B 1 RF SCOUT PLUS INSTRUCTION MANUAL Dielectric, LLC 22 Tower Rd. Raymond, ME 04071 Phone: 800.341.9678 www.dielectric.com 21 January 2015, Rev B 1 WARNING Powering RF sensors above +30dBm (1W) will cause

More information

Grandstream Networks, Inc. GDS3710 Input/output Connection Guide

Grandstream Networks, Inc. GDS3710 Input/output Connection Guide Grandstream Networks, Inc. Table of Contents INTRODUCTION... 4 GDS3710 WIRING CONNECTION... 5 Powering and Connecting the GDS3710... 5 Power and Data PINs... 5 Alarm In and Alarm Out PINs... 6 DETECT AND

More information

PBI Manual. Paradox to KNX-BUS Interface

PBI Manual. Paradox to KNX-BUS Interface PBI 64-192 Paradox to KNX-BUS Interface Manual GDS Intelligence in Buildings El. Benizelou 116 Nea Erithrea, 14671 Phone: +30 2108071288 Email: info@gds.com.gr Web: gds.com.gr Contents 1 Device description...

More information

WeatherLink for Alarm Output Addendum

WeatherLink for Alarm Output Addendum WeatherLink for Alarm Output Addendum Introduction This Streaming Data Logger is designed to provide an electrical interface between a Vantage Pro or Vantage Pro2 weather station console or Weather Envoy

More information

Simplex Panel Interface Guide

Simplex Panel Interface Guide Simplex Panel Interface Guide February 2016 SATEON Software Integrations Simplex Panel Interface Guide Issue 1.0, released February 2016 Disclaimer Copyright 2016, Grosvenor Technology. All rights reserved.

More information

IndigoVision Alarm Panel. User Guide

IndigoVision Alarm Panel. User Guide IndigoVision Alarm Panel User Guide THIS MANUAL WAS CREATED ON 2/21/2017. DOCUMENT ID: IU-AP-MAN002-4 Legal considerations LAWS THAT CAN VARY FROM COUNTRY TO COUNTRY MAY PROHIBIT CAMERA SURVEILLANCE. PLEASE

More information

NetGuardian DIN/ NetDog DIN

NetGuardian DIN/ NetDog DIN NetGuardian DIN/ NetDog DIN USER MANUAL D-PK-NGDIN Visit our website at www.dpstelecom.com for the latest PDF manual and FAQs. July 2, 2018 D-UM-NGDIN Firmware Version 1.0A Revision History July 2, 2018

More information

Model 135 Reference Document

Model 135 Reference Document Model 135 Reference Document 2007 by Gordon Kapes, Inc. all rights reserved 5520 West Touhy Avenue Skokie, Illinois 60077 USA Telephone 847 676-1750 Fax 847 982-0747 www.gkinc.com 40218, Issue 1 January

More information

Security System. User Guide for the LED Command Center

Security System. User Guide for the LED Command Center Security System User Guide for the LED Command Center National Security Systems Inc (800)457-1999 MY SECURITY COMPANY IS: CALL BEFORE TEST: THIS SECURITY SYSTEM IS CONNECTED TO TELEPHONE NUMBER: THE SECURITY

More information

IntesisBox BACnet/IP Server - Notifier ID3000 series

IntesisBox BACnet/IP Server - Notifier ID3000 series IntesisBox Server - Notifier ID3000 series Gateway for integration of Notifier ID3000, ID3002, ID50 and ID60 fire panels into enabled control systems. Integrate your Notifier fire panels into your BACnet

More information

725B Configuration Software Manual

725B Configuration Software Manual 725B Configuration Software Manual REV DATED DESCRIPTION AUTHOR APPROVED 0 09-03-10 First Issue P.Cartmell Page 1 of 80 SECTION 1 - SOFTWARE INSTALLATION... 5 725B ConfigurationSoftware Installation...

More information

CBI-064. User Manual. Caddx to KNX-BUS Interface

CBI-064. User Manual. Caddx to KNX-BUS Interface CBI-064 Caddx to KNX-BUS Interface User Manual GDS Intelligence in Buildings El. Venizelou 116 Nea Erithrea 14671 Tel: +30 2108071288 Email: info@gds.com.gr Web: gds.com.gr Contents 1 Device Description...

More information

USER MANUAL FOR OPERATING SYSTEM

USER MANUAL FOR OPERATING SYSTEM P2262 ALARM PANEL USER MANUAL FOR OPERATING SYSTEM 21765-07 September 1999 Associated Controls (Aust) PTY. LTD. 29 Smith Street, Hillsdale, NSW, 2036. PH (02) 9311 3255, FAX (02) 9311 3779 Page 1 of 177

More information

Instruction Manual Model Backup Switch, 1 for 8

Instruction Manual Model Backup Switch, 1 for 8 Instruction Manual Model 2582-282 Backup Switch, 1 for 8 December 2011, Rev. 0 MODEL 2582 SWITCH CROSS TECHNOLOGIES INC. SWITCH ALARM PSA PSB ALARM OFFLINE ONLINE UNIT STATUS 1 2 3 4 5 6 7 8 BU PROT MODE

More information

ACCURATE ELECTRONICS INC PO BOX SW HALL BLVD BEAVERTON OR USA FAX

ACCURATE ELECTRONICS INC PO BOX SW HALL BLVD BEAVERTON OR USA FAX Page 1 of 10 Model 10807800 January 2014 ACCURATE ELECTRONICS INC PO BOX 1654 97075-1654 8687 SW HALL BLVD 97008 BEAVERTON OR USA 503.641.0118 FAX 503.646.3903 WWW.ACCURATE.ORG Practice Section 10807800

More information

Pipo Communications. Model ST-888. DTMF ANI/ENI Display Decoder

Pipo Communications. Model ST-888. DTMF ANI/ENI Display Decoder Pipo Communications Model ST-888 DTMF ANI/ENI Display Decoder 1516 Cassil Place Hollywood, California 90028-7106 Phone: 323-466-5444 Fax: 323-466-1520 www.pipo.cc Manual # 68-9888 May 1, 2002 Rev. 5/02

More information

Monitoring Operator Guide. Access Control Manager Software Version

Monitoring Operator Guide. Access Control Manager Software Version Monitoring Operator Guide Access Control Manager Software Version 5.10.10 2018, Avigilon Corporation. All rights reserved. AVIGILON, the AVIGILON logo, ACCESS CONTROL MANAGER, ACM, ACM VERIFY AND TRUSTED

More information

M3092 Programmer. User s Manual. M3096B-33 E Copyright 2017 SELCO

M3092 Programmer. User s Manual. M3096B-33 E Copyright 2017 SELCO User s Manual Copyright 2017 SELCO SELCO Betonvej 11 - DK-4000 Roskilde Denmark Phone: 45 7026 1122 - Fax: 45 7026 2522 e-mail: selco@selco.com www.selco.com Table of contents 1 INTRODUCTION...4 2 SOFTWARE

More information

Sirius Control Box 6130 LRIT

Sirius Control Box 6130 LRIT Sirius Control Box 6130 LRIT Long-Range Identification and Tracking Owner s & Installation Manual Version 1.12 - 2 - Sirius Control Box 6130 LRIT Disclaimer Sirius is a brand name owned by Polaris Electronics

More information

Ademco Vista Alarm Panel

Ademco Vista Alarm Panel System Galaxy Quick Guide CONFIGURATION AND OPERATION Ademco Vista Alarm Panel JAN 2018 SG 10.5.6 System Galaxy Quick Guide For Ademco Vista Panel Configuration & Operation 2nd edition JAN 2018 Information

More information

SNMP Solutions Cookbook By Bob Berry

SNMP Solutions Cookbook By Bob Berry Interfaces 202 212 232 485 FSK PSK LAN Dial-up Service Channels Overheads Protocols ASCII TL1 DCM DCP E2 FX8800 Modbus TABS TBOS TRIP POP3 NTP Ping SNMP Teltrac X.25 NEC 21SV Badger Cordell Datalok Felix

More information

Telemetry Communications Device. Installation Guide. Interface for the Emizon managed network. Issue 1: February 2008

Telemetry Communications Device. Installation Guide. Interface for the Emizon managed network. Issue 1: February 2008 TCD Telemetry Communications Device Installation Guide Interface for the Emizon managed network Issue 1: February 2008 This guide sets out a simple check list together with a step-by-step guide to the

More information

E N G L I S H FIRE ALARM ASPIRATION SENSING TECHNOLOGY QUICK INSTALLATION GUIDE STAND-ALONE FAAST LT MODELS FL0111E FL0112E FL0122E. 367 mm.

E N G L I S H FIRE ALARM ASPIRATION SENSING TECHNOLOGY QUICK INSTALLATION GUIDE STAND-ALONE FAAST LT MODELS FL0111E FL0112E FL0122E. 367 mm. E N G L I S H FIRE ALARM ASPIRATION SENSING TECHNOLOGY QUICK INSTALLATION GUIDE STAND-ALONE FAAST LT MODELS FL0E FL0E FL0E mm mm 0 mm DESCRIPTION The LT FL0 Series is part of the Fire Alarm Aspiration

More information

P2267 NETWORK INTERFACE

P2267 NETWORK INTERFACE P2267 NETWORK INTERFACE USER MANUAL FOR OPERATING SYSTEMS: 22031-03 23636-01 October 2009 Associated Controls (Australia) Pty. Limited 2-4 Norfolk Road Greenacre, NSW, 2190. PH +61 2 9642 4922, FAX +61

More information

Halton SAFE / 7.14 user guide and installation instructions

Halton SAFE / 7.14 user guide and installation instructions Halton SAFE / 7.14 user guide and installation instructions VERIFIED SOLUTIONS BY H A LTO N Enabling Wellbeing Table of contents 1 System description 3 2 User Accounts 4 3 Main menu 7 3.1 Main menu - Change

More information

BROADBAND MODEL WITH REMOTE POWER CONTROL (SERIES 2) ICT180S-12BRC (FOR POSITIVE GROUND SYSTEMS) ICT180S-12BRCP (FOR NEGATIVE GROUND SYSTEMS)

BROADBAND MODEL WITH REMOTE POWER CONTROL (SERIES 2) ICT180S-12BRC (FOR POSITIVE GROUND SYSTEMS) ICT180S-12BRCP (FOR NEGATIVE GROUND SYSTEMS) The Power of Reliability BROADBAND MODEL WITH REMOTE POWER CONTROL (SERIES 2) ICT180S-12BRC (FOR POSITIVE GROUND SYSTEMS) ICT180S-12BRCP (FOR NEGATIVE GROUND SYSTEMS) INSTRUCTION MANUAL TABLE OF CONTENTS

More information

Supervisor Standard Edition

Supervisor Standard Edition Supervisor Standard Edition Installation Manual Heat-Tracing Controller Configuration and Monitoring Software INSTALL-119 (Europe) 1 / 18 Contents Section 1 Introduction...3 1.1 Welcome...3 1.2 Vital Information...3

More information

IRIS Touch Quick Installation & Maintenance Guide. Version 1.0

IRIS Touch Quick Installation & Maintenance Guide. Version 1.0 IRIS Touch Quick Installation & Maintenance Guide Version 1.0 Page 2 of 16 IRIS Touch Quick Installation & Maintenance Guide Version 1.0 Contents 1. Introduction... 4 2. Product Features... 4 3. Package

More information

G2 USER MANUAL D-PK-TDFG2

G2 USER MANUAL D-PK-TDFG2 TempDefender G2 USER MANUAL D-PK-TDFG2 Visit our website at www.dpstelecom.com for the latest PDF manual and FAQs. May 3, 208 D-UM-TDFG2 Firmware Version 2.0A Revision History M ay 3, 208 Added High-Security

More information

rvm4c Installation Guide Remote Video Module

rvm4c Installation Guide Remote Video Module rvm4c EN Installation Guide Remote Video Module rvm4c Installation Guide Installation Diagrams EN 2 Installation Diagrams for the Transmitting Unit rvm4c Installation Guide Basic Hardware Installation

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS The SensorNet I/O Module provides attachment for up to 32 alarms and up to 16 switched devices. An RS-232 or RS-422 communications port is also provided for receiving serial alarms.

More information

Alarm module for leak detection with webserver

Alarm module for leak detection with webserver This instruction document consists of 2 parts : one part about the assembly of the components and one part about configuration and starting-up of the system. The assembly is done by the qualified installer

More information

CPS3200U Technical Support Guide

CPS3200U Technical Support Guide CPS3200U Technical Support Guide Product Manual Comcode CC848853457 Issue 1 September 2008 7 1 COMPACT POWER LINE SHELVES MODELS J85480S1 AND J2007001 Ordering Guide June 2008 Matrix File # CC848849397-MAN

More information

AUTOMATION. Operator s Manual RST Series Web Enabled Input Module. Rev. A2, 1/12

AUTOMATION. Operator s Manual RST Series Web Enabled Input Module. Rev. A2, 1/12 AUTOMATION P R O D U C T S GROUP, INC. Operator s Manual RST-5000 Series Web Enabled Input Module Rev. A2, 1/12 Tel: 1/888/525-7300 Fax: 1/435/753-7490 www.apgsensors.com E-mail: sales@apgsensors.com RST-5000

More information

VersAlarm. Installation & Operation Manual

VersAlarm. Installation & Operation Manual VersAlarm Installation & Operation Manual Digitize, Inc. 158 Edison Road Lake Hopatcong, New Jersey 07849 Tel: (973) 663-1011 Part Number: 700290-0001 Fax: (973) 663-4333 Revision: A E-mail: info@digitize-inc.com

More information

ModBus DE-1 INSTALLATION AND USER MANUAL

ModBus DE-1 INSTALLATION AND USER MANUAL ModBus DE-1 INSTALLATION AND USER MANUAL INTESIS Software, SL Distributed by DURAN ELECTRONICA S.L Tomás Bretón 50 28045 MADRID, España duran@duranelectronica.com www.duranelectronica.com 2 2010 DURAN

More information

DCA4. Digitally controlled Audio Matrix. Current Thinking. Product Specification March Document Number DDC DCA ACS

DCA4. Digitally controlled Audio Matrix. Current Thinking. Product Specification March Document Number DDC DCA ACS DCA4 Digitally controlled Audio Matrix Product Specification March 2002 Current Thinking Document Number DDC DCA 7001 01 ACS Introduction Voice Alarm (VA) systems are the quickest way to evacuate the public

More information

DC VOLTMETER DCV-10 / 10A / 10C / 10S / 10CS / 11 / 11A / 11C / 11S / 11CS. A4741 / Rev.1

DC VOLTMETER DCV-10 / 10A / 10C / 10S / 10CS / 11 / 11A / 11C / 11S / 11CS.  A4741 / Rev.1 DC VOLTMETER DCV-10 / 10A / 10C / 10S / 10CS / 11 / 11A / 11C / 11S / 11CS User Manual and Menu Map A4741 / Rev.1 www.entes.com.tr ATTENTION -Disconnect all power before connecting the device. -Don t remove

More information

FlameGard 5 UV/IR HART

FlameGard 5 UV/IR HART FlameGard 5 UV/IR HART HART Communication Manual The information and technical data disclosed in this document may be used and disseminated only for the purposes and to the extent specifically authorized

More information

Smart Combiners Installation Guide. For Obvius A89DC-08 sensor modules

Smart Combiners Installation Guide. For Obvius A89DC-08 sensor modules For Obvius A89DC-08 sensor modules Introduction Large roof and ground arrays connect the panels into stings that are merged together in combiner boxes. Each string will typically consist of 10-15 panels

More information

MultiSite Manager. Setup Guide

MultiSite Manager. Setup Guide MultiSite Manager Setup Guide Contents 1. Introduction... 2 How MultiSite Manager works... 2 How MultiSite Manager is implemented... 2 2. MultiSite Manager requirements... 3 Operating System requirements...

More information

UAS 7000 Local Management

UAS 7000 Local Management Issue 2, October 1998 Operation UAS 7000 Local Management Includes Support for: UAS 7001 NIU UAS 7002 NIU UAS 7616 DIU UAS 7616M DIU UAS 7626 DIU General DataComm, Inc. Preface iii Local Management Access...

More information

ICT180S-12I INTELLIGENT MODEL (SERIES 2)

ICT180S-12I INTELLIGENT MODEL (SERIES 2) The Power of Reliability ICT180S-12I INTELLIGENT MODEL (SERIES 2) INSTRUCTION MANUAL TABLE OF CONTENTS Warnings Page 2 Product Description Page 3 Installation Page 4 LCD/Select Button Operation Page 7

More information

Centroid Snet 2. Battery Management Software. User Manual V1.1. Eagle Eye Power Solutions, LLC Keeping an Eye on Your Critical Power!

Centroid Snet 2. Battery Management Software. User Manual V1.1. Eagle Eye Power Solutions, LLC Keeping an Eye on Your Critical Power! Eagle Eye Power Solutions, LLC Keeping an Eye on Your Critical Power! Centroid Snet 2 Battery Management Software User Manual V1.1 www.eepowersolutions.com Tel: 1-877-805-3377 info@eepowersolutions.com

More information

FCD-wire Contents. List of Figures

FCD-wire Contents. List of Figures FCD-wire Contents FCD-X21 Configuration 1 Introduction... 1 2 Opening the FCD Application... 1 3 FCD Window... 2 4 FCD LEDs... 3 5 Configuration Operations... 4 FCD Info...4 FCD System Info...5 FCD Interface

More information

Compod. Instruction Manual IM-COMPOD Revision: F, December 2015

Compod. Instruction Manual IM-COMPOD Revision: F, December 2015 Compod Programmable Control Module For 100 Series Digital Mass Flow Meters & Controllers Instruction Manual IM-COMPOD Revision: F, December 2015 CORPORATE HEADQUARTERS 5 Harris Court, Building L, Monterey,

More information

FL500 Modbus Communication Operating Manual. Order No.: /00. MSAsafety.com

FL500 Modbus Communication Operating Manual. Order No.: /00. MSAsafety.com FL500 Modbus Communication Operating Manual Order No.: 10193214/00 MSAsafety.com 1000 Cranberry Woods Drive Cranberry Township, PA 16066 A Phone 1-800-MSA-2222 Fax 1-800-967-0398 For your local MSA contacts

More information

CSP-204 CSP-208 CSP-104 CSP-108

CSP-204 CSP-208 CSP-104 CSP-108 Fire Alarm Control Panel CSP-204 CSP-208 CSP-104 CSP-108 Operation manual Firmware version 1.1 csp-x_o_en 06/15 SATEL sp. z o.o. ul. Budowlanych 66 80-298 Gdańsk POLAND tel. 58 320 94 00 www.satel.eu CONTENTS

More information

Security System. User s Guide for the Text Command Center

Security System. User s Guide for the Text Command Center User s Guide for the Text Command Center MY ALARM COMPANY IS: CALL BEFORE TEST: THIS SECURITY SYSTEM IS CONNECTED TO TELEPHONE NUMBER: THE SECURITY CONTROL PANEL IS CONNECTED TO THE PHONE JACK LOCATED:

More information

21-light Remote Annunciator. Owner s Manual

21-light Remote Annunciator. Owner s Manual 21-light Remote Annunciator Owner s Manual Annunciator Description... Inside Font Cover Detailed Specifications... 1 Environmental Specifications... 1 Power Supply Requirements... 1 Communication With

More information

IRIS Touch Quick Installation & Maintenance Guide. Version 1.0

IRIS Touch Quick Installation & Maintenance Guide. Version 1.0 IRIS Touch Quick Installation & Maintenance Guide Version 1.0 Page 2 of 16 IRIS Touch Quick Installation & Maintenance Guide Version 1.0 Contents 1. Introduction...4 2. Product Features...4 3. Package

More information

Operations Manual TS400. Test Station for G450/G460 Gas Detector

Operations Manual TS400. Test Station for G450/G460 Gas Detector TS400 Test Station for G450/G460 Gas Detector Operations Manual 1194 Oak Valley Dr, Ste 20, Ann Arbor MI 48108 USA (800) 959-0329 (734) 769-0573 www.goodforgas.com GfG Products for Increased Safety Congratulations

More information

PTE0705 Electric Fence Monitor

PTE0705 Electric Fence Monitor PTE0705 Electric Fence Monitor The JVA logo is a registered trademark of JVA Technologies. JVA Technologies. TABLE OF CONTENTS DESCRIPTION... 2 QUICK START GUIDE... 3 FEATURES... 4 EXPLANATION OF TERMS...

More information

CMC-TC Basic CMC DK

CMC-TC Basic CMC DK CMC-TC DK 7320. Assembly, Installation and Operation A36569 05IT 74 Microsoft Windows is a registered trademark of Microsoft Corporation. Acrobat Reader is a registered trademark of Adobe Systems Incorporated.

More information

ACTIVE INFRARED BARRIER

ACTIVE INFRARED BARRIER Although PROTECH provides high security indoor intrusion sensors for the military and government markets, our specialty is outdoor protection. Since we first introduced our PIRAMID outdoor dual technology

More information

Manage Alarms. Before You Begin CHAPTER

Manage Alarms. Before You Begin CHAPTER CHAPTER 8 Manage Alarms This chapter contains the procedures for viewing and managing the alarms and conditions on a Cisco ONS 15454. Cisco Transport Controller (CTC) detects and reports alarms generated

More information

iminiplus PDF User Guide Version 2.0

iminiplus PDF User Guide Version 2.0 iminiplus PDF User Guide Version 2.0 Table of contents 1 Scope of this document... 3 2 Why PDF?... 3 3 Logger profile... 3 4 What you need to get started... 4 5 FDA 21 CFR Part 11 compliance... 5 6 How

More information

Avigilon Control Center System Integration Guide

Avigilon Control Center System Integration Guide Avigilon Control Center System Integration Guide with Gallagher Command Centre INT-CARDAX-C-Rev3 Copyright 2013 Avigilon. All rights reserved. No copying, distribution, publication, modification, or incorporation

More information

MicroTech Series 200 Centrifugal Chiller

MicroTech Series 200 Centrifugal Chiller Protocol Data Information Packet Version 2.2 Group: Controls Date: March 1999 MicroTech Series 200 Centrifugal Chiller Data Communications Packet for Protocol 2002 McQuay International Revision History

More information

Alarm Coordination Connected Components Building Block. Quick Start

Alarm Coordination Connected Components Building Block. Quick Start Alarm Coordination Connected Components Building Block Quick Start Important User Information Solid state equipment has operational characteristics differing from those of electromechanical equipment.

More information

Galaxy Pulsar Plus Digital Battery Plant Controller

Galaxy Pulsar Plus Digital Battery Plant Controller Galaxy Pulsar Plus Digital Battery Plant Controller Features Supports up to 60 Power Modules rectifiers and converters Supports dual voltage plants, with rectifiers and converters Auto-sensing dual voltage

More information

E N G L I S H FIRE ALARM ASPIRATION SENSING TECHNOLOGY QUICK INSTALLATION GUIDE ADDRESSABLE FAAST LT MODELS MI-FL2011EI, MI-FL2012EI AND MI-FL2022EI

E N G L I S H FIRE ALARM ASPIRATION SENSING TECHNOLOGY QUICK INSTALLATION GUIDE ADDRESSABLE FAAST LT MODELS MI-FL2011EI, MI-FL2012EI AND MI-FL2022EI E N G L I S H FIRE ASPIRATION SENSING TECHNOLOGY QUICK INSTALLATION GUIDE ADDRESSABLE FAAST LT MODELS MI-FL0EI, MI-FL0EI AND MI-FL0EI mm mm 0 mm DESCRIPTION The LT MI-FL0 Series is part of the Fire Alarm

More information

System Galaxy Quick Guide

System Galaxy Quick Guide System Galaxy Quick Guide CONFIGURATION AND OPERATION Integrating CCTV with System Galaxy JAN 2019 SG 11.1.0.2 System Galaxy Quick Guide For CCTV Integration Configuration & Operation Information in this

More information

MegaPower CPU ADMPCPU

MegaPower CPU ADMPCPU MegaPower CPU ADMPCPU Administrator s Guide 8200-0421-03 J MegaPower CPU Administrator s Guide Figure 1. MegaPower 3200 Video-Matrix Closed-Circuit Television (CCTV) System Cameras Video Data ADDL* Protocol

More information

WebAlert WA500 Series Process Monitor Instruction Manual

WebAlert WA500 Series Process Monitor Instruction Manual W A L C H E M IWAKI America Inc. WebAlert WA500 Process Monitor WebAlert WA500 Series Process Monitor Instruction Manual Five Boynton Road Hopping Brook Park Holliston, MA 01746 USA TEL: 508-429-1110 FAX:

More information