FCD-wire Contents. List of Figures

Size: px
Start display at page:

Download "FCD-wire Contents. List of Figures"

Transcription

1 FCD-wire Contents FCD-X21 Configuration 1 Introduction Opening the FCD Application FCD Window FCD LEDs Configuration Operations... 4 FCD Info...4 FCD System Info...5 FCD Interface Info...6 Setting the Date Format and Time Fault Operations... 8 Alarms...8 History Log...11 FCD Self Test Results Options Menu Manager List Port Operations Displaying Port s Fault Operations Displaying Port Alarms Diagnostics Operations Diagnostic Tests...21 List of Figures 1. FCD-G703 in Focus FCD-V35 in Focus FCD-X21 in Focus FCD Information FCD System Information FCD Interface Information Date & Time Setup Mask System Alarms FCD All Active Alarm List FCD Active Alarm List Alarm Trap Dialog Box Alarm Buffer List FCD Agent Self-test Results Manager List Port Information Loop Control BERT s Dialog Box Port Software Configuration Dialog Box i

2 Table of Contents 19. Call Out Destinations Dialog Box Port Mask Alarms Port Active Alarm List Port Tests BERT Counters Dialog Box Port BERT Polling List of Tables 1. FCD G703 LEDs FCD - V35 LEDs FCD - X21 LEDs FCD Information s FCD Date & Time Setup s FCD System Level Alarms FCD All Active Alarm List s FCD Active Alarm List s Alarm Report s Alarm Buffer List s Manager List s Loop Control s BERT s Port Software Configuration s Call Out Destinations s FCD Alarms Port Active Alarm List Port Tests BERT s ii

3 FCD-G.703, FCD-V.35 and FCD-X21 Configuration This chapter explains the operations that are performed when configuring the FCD. 1 Introduction Note RADview-HPOV provides a complete solution for monitoring and controlling the FCD-G703, FCD-V35 and FCD-X21. In this chapter, FCD refers to the FCD-G703, FCD-V35 and FCD-X21, unless otherwise noted. 2 Opening the FCD Application To open the FCD application: Double-click on an FCD icon on a map. To open the application, communication must be established with the Agent. A message window announces that this is happening. If communication is established, the message window closes and the FCD window is displayed. If communication is not established (the application cannot be opened), a message box appears displaying the following message No communication between NMS and Agent. Click OK to close the window. Opening the FCD Application 1

4 FCD-G.703, FCD-V.35 and FCD-X21 Configuration 3 FCD Window When the FCD is in focus, the menus Configuration, Fault, Options and Help are enabled. The Diagnostics menu is disabled. Figure 1. FCD-G703 in Focus Figure 2. FCD-V35 in Focus Figure 3. FCD-X21 in Focus 2 FCD Window

5 FCD-G.703, FCD-V.35 and FCD-X21 Configuration 4 FCD LEDs The state of the LEDs indicates the status of the FCD. The LEDs are different for each FCD type. The following tables list the different LEDs and explain their different states (On/Off). Table 1. FCD G703 LEDs LED Name Color Remarks On Off PWR Green Always TST Yellow Test is running on one of the ports No test is running on any port ALM Red There are alarms in the system There are no alarms in the system USER - LOS Red Signal is detected No signal is detected USER - TD Yellow Always USER - RD Yellow Always NETWORK - LOS Red Signal is detected No signal is detected Table 2. FCD - V35 LEDs LED Name Color Remarks On Off PWR Green Always TST Yellow Test is running on one of the ports No test is running on any ports ALM Red There are alarms in the system There are no alarms in the system USER - DTR Yellow Signal is detected No signal is detected USER - RTS Yellow Signal is detected No signal is detected USER - TD Yellow Always USER - RD Yellow Always NETWORK - DSR Yellow Signal is detected No signal is detected NETWORK - DCD Yellow Signal is detected No signal is detected NETWORK - CTS Yellow Signal is detected No signal is detected FCD LEDs 3

6 FCD-G.703, FCD-V.35 and FCD-X21 Configuration Table 3. FCD - X21 LEDs Remarks LED Name Color On Off PWR Green Always -- TST Yellow When a test is running on one of the ports. ALM Red When there are alarms in the system. When no test is running on any port. When there are no alarms in the system. USER CNT Yellow When signal is detected. When signal is not detected. USER TD Yellow Always USER RD Yellow Always NETWORK - IND Yellow When signal is detected. When signal is not detected. 5 Configuration Operations You can perform the following configuration procedures: Displaying FCD information Displaying and configuring FCD system information Displaying FCD interface information Setting the Date Format & Time. FCD Info The FCD Information dialog box contains status information about the FCD. To view or modify the FCD information parameters: 1. From the Configuration menu, select FCD Info... The FCD Information dialog box appears. 2. Click Close after reviewing the parameters. 4 Configuration Operations

7 FCD-G.703, FCD-V.35 and FCD-X21 Configuration Figure 4. FCD Information Table 4. FCD Information s IP Address SW Revision HW Version Self Test Result Address of the selected WAN agent (double-clicked in the WAN submap) Agent software version Agent hardware version Status of the Self Test Switches Status SP-Par Source of the supervisory port parameters Default = 1 Other = 0 PSWRD Source of the password and management address (node number) of the supervisory port. Default = 1 User Selected = 0 FCD System Info The FCD System Information dialog box displays system information parameters for the FCD. To view or modify the FCD system information parameters: 1. From the Configuration menu, select System Info... The FCD System Information dialog box appears. 2. Type the required changes. You may update Name, Contact and Location. 3. Click Set to implement the changes. Configuration Operations 5

8 FCD-G.703, FCD-V.35 and FCD-X21 Configuration Figure 5. FCD System Information FCD Interface Info The FCD System Information dialog box displays system information parameters for the FCD. To view or modify the FCD system information parameters: 1. From the Configuration menu, select Interface Info... The FCD Interface Information dialog box appears. The Interface Information parameters are read-only. 2. Click Close after reviewing the parameters. Figure 6. FCD Interface Information 6 Configuration Operations

9 FCD-G.703, FCD-V.35 and FCD-X21 Configuration Setting the Date Format and Time You can set the time and date format for the FCD in one of three formats: European (DD/MM/YYYY), American (MM/DD/YYYY) or YYYY-MM-DD. To set the date format: 1. From the Configuration menu, select Date Format> followed by one of the following formats: -- European (DD/MM/YYYY) -- American (MM/DD/YYYY) -- YYYY-MM-DD where DD = day, MM = month and YYYY = year. 2. From the Configuration menu, select Date & Time... The Date & Time Setup dialog box appears. 3. Enter the correct parameters. 4. Click Set to implement the changes. Figure 7. Date & Time Setup Table 5. FCD Date & Time Setup s Format This parameter is read-only DD/MM/YYYY (European), MM/DD/YYYY (American), YYYY-MM-DD Date Month Day Date according to the FCD's own real-time clock. Jan., Feb., Mar., Apr., May., Jun., Jul., Aug., Sep., Oct., Nov. and Dec. The day. Number of days varies depending on the selected Month Year Time Time according to the FCD's own real-time clock. Time format is hh:mm:ss. Configuration Operations 7

10 FCD-G.703, FCD-V.35 and FCD-X21 Configuration 6 Fault Operations The Fault menu contains options for: Displaying active alarms for the FCD Viewing a history log of alarms Viewing FCD self-test results. Alarms Masking System Alarms The Mask command displays a list of alarms that can be masked. To mask system level FCD alarms: 1. From the Fault menu, select Alarms followed by Mask... The FCD Mask System Alarms dialog box appears. You can mask all system level alarms or any other combination from the list. 2. Select the system level alarms to be masked. 3. Click Set to implement the changes. Figure 8. Mask System Alarms 8 Fault Operations

11 FCD-G.703, FCD-V.35 and FCD-X21 Configuration Table 6. FCD System Level Alarms RTC Battery Failure Alarm Buffer Overflow Hardwar Failure DB Init Switch is ON SP Dial Cycle Failed DB Checksum Error PSWRD Switch is ON SP-PAR Switch is ON PC-SP Switch is ON SP Primary Call Failed SP Alternate Call Failed Self Test Error Alarm IN Activated Masked (selected) and Unmasked Masked (selected) and Unmasked Masked (selected) and Unmasked Masked (selected) and Unmasked Masked (selected) and Unmasked Masked (selected) and Unmasked Masked (selected) and Unmasked Masked (selected) and Unmasked Masked (selected) and Unmasked Masked (selected) and Unmasked Masked (selected) and Unmasked Masked (selected) and Unmasked Masked (selected) and Unmasked Note Displaying All Active Alarms The List> All... command displays a list of active unmasked alarms for the selected FCD, including system (agent), card and port alarms. To view all active FCD alarms: From the Fault menu, select Alarms followed by List> and All... The FCD All Active Alarm List appears. If there are no unmasked alarms, the list will be empty and END will be displayed. This table displays active system, card and port alarms. If the list is long, you can scroll to display more entries. Figure 9. FCD All Active Alarm List Fault Operations 9

12 FCD-G.703, FCD-V.35 and FCD-X21 Configuration Table 7. FCD All Active Alarm List s No. Code Port Description Status [Print] Index number of the alarm Code which indicates a certain alarm description Port in which the alarm originated. Applicable only for port alarms Network, User Description of the alarm State of the alarm Minor, Major Prints list Note Displaying System Level Alarms The List> System Level... command displays a list of active unmasked alarms for the selected FCD only. To view all active FCD system level alarms: From the Fault menu, select Alarms, followed by List> and System Level... The FCD Active Alarm List appears. If there are no active alarms, the list will be empty and END will be displayed. This table displays active system alarms. If the list is long, you can scroll to display more entries. Figure 10. FCD Active Alarm List Table 8. FCD Active Alarm List s No. Code Description Status [Print] Index number of the alarm Code which indicates a certain alarm description Description of the alarm State of the alarm Prints list 10 Fault Operations

13 FCD-G.703, FCD-V.35 and FCD-X21 Configuration Clearing FCD Alarms You can clear only system level alarms or all active alarms from the system database. To clear active system level alarms: From the Fault menu, select Alarms followed by Clear. The system does not request confirmation for this operation. To clear all active alarms: From the Fault menu, select Alarms followed by Clear All. The system does not request confirmation for this operation. Alarms Report The Fault> Alarms> Report... command allows you to define when the Alarm On events are reported by traps based on the alarm severity. To define an alarm report: 1. From the Fault menu, select Alarms followed by Reports... The Alarm Report dialog box appears. You can set the severity criteria for reporting alarms. 2. Select the type of Alarm Trap Report from the list and click Set. Figure 11. Alarm Trap Dialog Box Table 9. Alarm Report s Alarm Trap Report Defines whether you want to receive traps for all alarms or for only those alarms of at least a certain severity No Report: No alarm trap will be sent Major: Alarm trap will be sent only for Major alarms All: Alarm trap will be sent for all alarms History Log The history log contains all the alarms listed in the FCD alarm buffer. You may display and print its contents. Displaying Alarms To display all the alarms in the FCD alarm buffer: From the Fault menu, select History Log followed by List... Fault Operations 11

14 FCD-G.703, FCD-V.35 and FCD-X21 Configuration The Alarm Buffer List appears. Figure 12. Alarm Buffer List The Alarm Buffer List displays all recorded alarms from system and port levels since the last time the log was cleared. If the list is long, you can scroll to display more entries. The table provides the following information about each alarm: Table 10. Alarm Buffer List s No. Code Description Status Date Time [Print] [Save to file] Index number of the alarm Code which indicates a certain alarm description Description of the alarm State of the alarm Off, Event, Minor, Major Date when the alarm occurred Time when the alarm occurred in hh:mm format Prints list Saves list in file Specify whole path and file name Note If you don not specify a path, the file will be stored in the application s directory. Clearing the History Log The alarms in the History Log can be cleared. To clear all the alarms from the FCD alarm buffer: From the Fault menu, select History Log followed by Clear. The system does not request confirmation for this operation. 12 Fault Operations

15 FCD-G.703, FCD-V.35 and FCD-X21 Configuration FCD Self Test Results When powered, the FCD runs a self-test to detect hardware failures and to provide circuit-level diagnostics data. The Self Test command displays the results of the selected FCD self-tests. To display the FCD self-test results: From the Fault menu, select Self Test... The Self Test Results dialog box appears. Figure 13. FCD Agent Self-test Results This dialog box lists all possible detectable failures and the status of each failure. The available status options are: On Failure exists. Self-test was successful. Manager List 7 Options Menu The Options menu contains options for: Displaying/Updating the Manager List The Manager List displays addresses of management stations that can receive FCD traps. To receive an agent's traps, the management station must type its own IP address in the Manager List. To display/update the Manager List: Note 1. From the Options menu, select Manager List... The Manager List dialog box appears. The list may contain up to five entries. 2. Click an entry in the list. 3. Enter the desired IP address in the Edit field and click OK. 4. Click Set to update the IP Addresses. Options Menu 13

16 FCD-G.703, FCD-V.35 and FCD-X21 Configuration Figure 14. Manager List Table 11. Manager List s Manager ID IP Address Index number in the list of the management station. IP address of the management station. 8 Port Operations You select a port by clicking it. A selected port is outlined by a blue frame. Selecting a port enables you to display software configuration information for the selected port. Displaying Port s When a port is selected, the Port Info> command enables you to display and/or edit the following: Information s Software Configuration s (SP ports only) Call Out Destinations s (SP ports only) Loop Control s (Network ports only) BERT s... (Network ports only) Port Information To display the port information: 1. Select the required port. 2. From the Configuration menu, select Port Info> followed by Information... The Port Information dialog box appears. The Port Information parameters are read-only. 14 Port Operations

17 FCD-G.703, FCD-V.35 and FCD-X21 Configuration Figure 15. Port Information Loop Control (network ports only) To display/edit the Loop Control: 1. Select the required port. 2. From the Configuration menu, select Port Info> followed by Loop Control... Note 3. Click Set to implement the changes. The Loop Control dialog box appears. Changing Inband Loop Detection from enabled to disabled while an Rx Inband loop is running on the network interface causes the loop to stop automatically. Figure 16. Loop Control Table 12. Loop Control s Port The selected port Network Inband Loop Detection Disabled, Enabled BERT s (network ports only) To view or edit the BERT s: 1. Select the required port. 2. From the Configuration menu, select Port Info> followed by BERT s... The BERT s dialog box appears. 3. Select desired parameters for BERT Pattern and BERT Error Injection Rate. 4. Click Set to implement the changes. Port Operations 15

18 FCD-G.703, FCD-V.35 and FCD-X21 Configuration Figure 17. BERT s Dialog Box Table 13. BERT s Port Network BERT Pattern 2E3-1, 2E4-1, 2E5-1, 2E6-1, 2E7-1, 511, 2E10-1, 2047, 2E15-1, 2E17-1, 2E18-1, 2E20-1, QRSS, 2E21-1, 2E22-1, 2E23-1, 2E25-1, 2E28-1, 2E29-1, 2E31-1 and 2E32-1 BERT Error Inject Rate (10E-) The rate of BERT injection No Error, 1, 2, 3, 4, 5, 6 and 7 Software Configuration (SP ports only) To display/edit the software configuration: 1. Select the SP port. 2. From the Configuration menu, select Port Info> followed by Software Configuration... The Port Software Configuration dialog box appears. 3. Click Set to implement changes to the Configuration. After clicking Set, a confirmation box appears displaying the following message New Data may cause disconnection of agent! Click OK to confirm. 16 Port Operations

19 FCD-G.703, FCD-V.35 and FCD-X21 Configuration Figure 18. Port Software Configuration Dialog Box Table 14. Port Software Configuration s Port Usage Rate (bps) Data Bits Parity Interface CTS The selected port Control (SP) Function of the selected port NMS Slip, Agent Slip, Terminal Operational speed, in bps, of the selected port Auto, 300, 1200, 2400, 4800, 9600, If Usage is NMS Slip, the only available options are 9600 and bps Number of data bits in the word format transmitted through the selected port 7, 8 Parity mode used by the selected port None, Odd, Even Type of supervisory port interface DCE (direct connection to supervision terminal), DTE (for connection through a modem to supervision terminal) State of the CTS (Clear to Send) line in the selected port On (CTS is always on), =RTS (CTS line follows the local RTS line) Port Operations 17

20 FCD-G.703, FCD-V.35 and FCD-X21 Configuration Table 14. Port Software Configuration s (cont.) DCD Delay (msec) DSR Time delay between Data Carrier Detection (DCD) and the sending of the data if the interface type is DTE 0, 10, 50, 100, 200, 300 When Interface is DCE the only available option is 0 State of the DSR line On (DSR line is continuously on), =DTR (DSR line tracks the DTR line) On is only applicable when Interface = DCE Dial-Out Call Out Trigger Dial Retries Wait for Connect (sec) Dial Mode Alternate No. Use Primary Dial No. Alternate Dial No. Type of trigger for the FCD to initiate a call None - Call-out is disabled All Alarms- FCD initiates a call after each new alarm, Major Alarms- FCD initiates a call when a new major alarm occurs Maximum number of retries to initiate a call 0 to 8 Time required, in seconds, for connection when the FCD initiates a call 30, 45, 60 Type of dialing. Tone, Pulse Yes enables the FCD to call the alternate number No, Yes Number that the FCD dials when it initiates a call Up to 20 characters Alternate number that the FCD dials if attempts to dial the primary number are unsuccessful Up to 20 characters This parameter is enabled only when Alternate No. Use = Yes Call Out Destinations (SP ports only) To display/edit the Call Out destinations: 1. Select the SP port. 2. From the Configuration menu, select Port Info> followed by Call Out Destinations... The Call Out Destinations dialog box appears. 3. Click an entry in the list. 18 Port Operations

21 FCD-G.703, FCD-V.35 and FCD-X21 Configuration 4. Enter the desired IP address in the Edit field and click OK. 5. Click Set to update the IP Addresses. Figure 19. Call Out Destinations Dialog Box Table 15. Call Out Destinations s Port The selected port SP Destination 1..5 IP Address to Fault Operations The Port View Fault menu contains options for: Masking active alarms Displaying active alarms Displaying Port Alarms Masking Alarms The Mask command enables the user to mask port level alarms. To set/view all masked alarms for the selected port: 1. From the Fault menu, select Alarms> and Mask... The Port Mask Alarms dialog box appears. 2. Select the alarms to be masked by clicking the appropriate checkbox. 3. Click Set to implement the changes. Fault Operations 19

22 FCD-G.703, FCD-V.35 and FCD-X21 Configuration Figure 20. Port Mask Alarms Table 16. FCD Alarms Loop Inband ON RX Clock Not Detected TX Clock Not Detected Signal Loss RTS Control is Off For Network G.703, V.35 and X.21 ports. For Network, G.703, V.35 and X.21 ports. For Network, G.703, V.35 and X.21 ports. For Network and User G.703 ports. For User V.35 and X.21 ports. Note Listing Active Alarms The List command displays a list of active alarms for the selected port. To view all active alarms for the selected port: From the Fault menu, select Alarms> and List... The Port Active Alarm List appears. If there are no active alarms, the list will be empty and END will be displayed. The Port Active Alarm List displays active port alarms. If the list is long, you can scroll bar to display more entries. Figure 21. Port Active Alarm List 20 Fault Operations

23 FCD-G.703, FCD-V.35 and FCD-X21 Configuration Table 17. Port Active Alarm List No. Code Description Status [Print] Index number of the alarm Code which indicates a certain alarm description Description of the alarm State of the alarm Minor, major Prints list Clearing Port Alarms You can clear all active port alarms from the system database. To clear active port level alarms: From the Fault menu, select Alarms> and Clear. The system does not request confirmation for this operation. Diagnostic Tests 10 Diagnostics Operations FCD supports local and remote loopback tests. Tx Inband, Rx Inband and BERT are also supported for network ports. RADview-HPOV's Diagnostics function allows you to do the following: View the status of diagnostic tests in the selected port Start a diagnostic test Stop a currently running diagnostic test. To enter the diagnostic test function: 1. Select a port. 2. From the Diagnostics menu, select Test... The Port Tests dialog box appears. Figure 22. Port Tests Diagnostics Operations 21

24 FCD-G.703, FCD-V.35 and FCD-X21 Configuration Table 18. Port Tests Port Running Tests Selected port Network, User Local Active, -- Remote Active, -- BERT Active, -- Only for Network ports Tx Inband Active, -- Only for Network ports Rx Inband Active, -- Only for Network ports Stop Tests Local Remote BERT Tx Inband Rx Inband Activate Local Remote BERT Tx Inband Rx Inband The Stop Tests group allows you to stop active tests Selected, Not Selected Selected, Not Selected Selected, Not Selected Only for Network ports Selected, Not Selected Only for Network ports Selected, Not Selected Only for Network ports When active, Rx Inband cannot be stopped by the user since it is initiated by the remote unit The Activate group lists the possible tests for the selected port Selected, Not Selected Selected, Not Selected Selected, Not Selected Only for Network ports Selected, Not Selected Only for Network ports Selected, Not Selected Only for Network ports When active, Rx Inband cannot be stopped by the user since it is initiated by the remote unit 22 Diagnostics Operations

25 FCD-G.703, FCD-V.35 and FCD-X21 Configuration To activate/deactivate a test: Select a test and Click Set. Note Note The agent stops and/or starts the selected tests accordingly. 1. Local and Remote tests cannot be activated together or with another test. 2. BERT and Tx Inband can be activated together or separately, but not with other tests. BERT (BER Testing) To view BERT results, BERT must be running. BERT Counters is available for network ports only. To display/edit the BERT Counters: 1. Select the network port. 2. From the Configuration menu, select Diagnostics followed by BERT Counters... The BERT Counters dialog box appears. Figure 23. BERT Counters Dialog Box Diagnostics Operations 23

26 FCD-G.703, FCD-V.35 and FCD-X21 Configuration Table 19. BERT s Port BERT Pattern BERT Error Inject Rate (10E-) Tx Inband Loop BERT Counters Run Time (sec) Errored Seconds Sync Loss Events Errored Bits Inject Error Command [Continuously] [Single] [Stop] [Polling] The selected port Network 2E3-1, 2E4-1, 2E5-1, 2E6-1, 2E7-1, 511, 2E10-1, 2047, 2E15-1, 2E17-1, 2E18-1, 2E20-1, QRSS, 2E21-1, 2E22-1, 2E23-1, 2E25-1, 2E28-1, 2E29-1, 2E31-1 and 2E32-1 This parameter is read-only. The rate of BERT injection No Error, 1, 2, 3, 4, 5, 6, 7 This parameter is read-only. Transmission status of the inband loop On, Off This parameter is read-only Lists the errored bits for the selected port Click [Continuously] to injects errors continuously Click [Single] to inject errors once Click [Stop] to cease injection of errors Click [Polling] to set BERT polling Interval in BERT Polling Interval dialog box. Possible values are 10 to 180 seconds (in 10 second intervals) Figure 24. Port BERT Polling [Clear Error Bits] Click [Clear Error Bits] to reset BERT Error Bits to zero 24 Diagnostics Operations

RADview-EMS/TDM. Element Management System for TDM Applications Optimux RAD Data Communications Publication 07/04

RADview-EMS/TDM. Element Management System for TDM Applications Optimux RAD Data Communications Publication 07/04 RADview-EMS/TDM Element Management System for TDM Applications Optimux-1553 1994 2004 RAD Data Communications Publication 07/04 Contents Chapter 1. Introduction 1.1 Overview... 1-1 1.2 System Features...

More information

UAS 7000 Local Management

UAS 7000 Local Management Issue 2, October 1998 Operation UAS 7000 Local Management Includes Support for: UAS 7001 NIU UAS 7002 NIU UAS 7616 DIU UAS 7616M DIU UAS 7626 DIU General DataComm, Inc. Preface iii Local Management Access...

More information

Laptop / PC Programming Manual

Laptop / PC Programming Manual Laptop / PC Programming Manual Doc. # Fire PC Program rev B 01.07 This Document is property of Evax Systems, Inc. The Evax Fire Solutions Programmer Components 2 1.0 System Setup 4 1.1 Interface Setup

More information

ibox Modbus Server Gateway for the integration of Notifier ID3000 / ID3002 / ID60 / ID50 fire panels in Modbus enabled monitoring and control systems

ibox Modbus Server Gateway for the integration of Notifier ID3000 / ID3002 / ID60 / ID50 fire panels in Modbus enabled monitoring and control systems Honeywell Life Safety Iberia C/Pau Vila 15-19; 08911 Badalona Barcelona T. 902 03 05 45; Internacional:+34932424236 www.honeywelllifesafety.es infohlsiberia@honeywell.com ibox Modbus Server Gateway for

More information

with internal sensor (channel 1) with an external sensor (channel 2) A-Editor software, Professional AK20 version (not for version AK4)

with internal sensor (channel 1) with an external sensor (channel 2) A-Editor software, Professional AK20 version (not for version AK4) Examples of use Example Creating an SMS-based alarm with confirmation A project file must first be created using the A-Editor software. This project file is then stored in the alarm modem. The alarm modem

More information

LineGuard 2300 Program User Manual (FloBoss 107)

LineGuard 2300 Program User Manual (FloBoss 107) Form A6251 Part Number D301346X012 November 2012 LineGuard 2300 Program User Manual (FloBoss 107) Remote Automation Solutions Revision Tracking Sheet November 2012 This manual may be revised periodically

More information

Quick Alert Remote (QA216R)

Quick Alert Remote (QA216R) Quick Alert Remote (QA216R) Description The QA 216 Remote is used by AT&T to monitor tower lights and turned down facilities. It is a 16-bit alarm unit used to transport discrete alarms from a remote location

More information

FlameGard 5 UV/IR HART

FlameGard 5 UV/IR HART FlameGard 5 UV/IR HART HART Communication Manual The information and technical data disclosed in this document may be used and disseminated only for the purposes and to the extent specifically authorized

More information

ION Meter Alerts TECHNICAL NOTE NOVEMBER In This Document

ION Meter Alerts TECHNICAL NOTE NOVEMBER In This Document 70072-0125-01 TECHNICAL NOTE NOVEMBER 2006 ION Meter Alerts A PowerLogic ION meter can send alerts to indicate a user specified power system condition such as a power quality problem (including surges,

More information

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge Replaceable LED modules 11 Alarm Sequences as per ISA-18.1 standard Each channel/window fully field programmable RS232 or RS485 MODBUS-RTU communication Repeat relay for each window and multifunction relays

More information

PWM. Solar Charge controller with Ethernet. Solar Smart PWM 20Amp. Hardware Description : Release : 19 June 2014

PWM. Solar Charge controller with Ethernet. Solar Smart PWM 20Amp. Hardware Description : Release : 19 June 2014 Solar Charge controller with Ethernet Release : 19 June 2014 Hardware Version : Version 1 Firmware version 1 PC Application Software : Version 1.0.0.0 Hardware Description : The Solar Smart regulator was

More information

PowerLogic ION Setup Meter Configuration Software Configuration Guide

PowerLogic ION Setup Meter Configuration Software Configuration Guide PowerLogic ION Setup Meter Configuration Software Configuration Guide 70002-0293-03 12/2010 Conventions Used in this Manual This section describes the symbols and terminology used in this guide. Symbols

More information

Monitoring Operator Guide. Access Control Manager Software Version

Monitoring Operator Guide. Access Control Manager Software Version Monitoring Operator Guide Access Control Manager Software Version 5.10.10 2018, Avigilon Corporation. All rights reserved. AVIGILON, the AVIGILON logo, ACCESS CONTROL MANAGER, ACM, ACM VERIFY AND TRUSTED

More information

Model 135 Reference Document

Model 135 Reference Document Model 135 Reference Document 2007 by Gordon Kapes, Inc. all rights reserved 5520 West Touhy Avenue Skokie, Illinois 60077 USA Telephone 847 676-1750 Fax 847 982-0747 www.gkinc.com 40218, Issue 1 January

More information

HERCULES 6 GRAPHICS SYSTEM

HERCULES 6 GRAPHICS SYSTEM HERCULES 6 GRAPHICS SYSTEM USER MANUAL Protec Fire Detection PLC, Protec House, Churchill Way, Nelson, Lancashire, BB9 6RT. Telephone: +44 (0) 1282 717171 Fax: +44 (0) 1282 717273 Web: www.protec.co.uk

More information

Added password for IP setup page : Password must be in IP format!

Added password for IP setup page : Password must be in IP format! NETWORK POWER MONITOR Release : 21 August 2014 Hardware Version : Version 7 Firmware version 1.00 PC Application Software : Version (latest)...2 Added password for IP setup page : Password must be in IP

More information

Configuration and Operation Manual for the Unipos

Configuration and Operation Manual for the Unipos AxxonSoft Configuration and Operation Manual for the Unipos Integration Module Version 1.1 Moscow 2010 Contents CONTENTS... 2 1 LIST OF TERMS... 4 2 INTRODUCTION... 6 2.1 Document purpose... 6 2.2 Purpose

More information

rvm4c Installation Guide Remote Video Module

rvm4c Installation Guide Remote Video Module rvm4c EN Installation Guide Remote Video Module rvm4c Installation Guide Installation Diagrams EN 2 Installation Diagrams for the Transmitting Unit rvm4c Installation Guide Basic Hardware Installation

More information

mti085 Temperature Interface

mti085 Temperature Interface Temperature Interface 1-WIRE INTRINSICALLY SAFE mti085 mti085 Temperature Interface Document No. 10432 Revision H July 2007 2001-2006 CMC Industrial Electronics Ltd. This page intentionally left blank

More information

NGC-UIT2 MODBUS PROTOCOL INTERFACE MAPPING FOR NGC-30 SYSTEMS. Firmware versions up to V2.0.X

NGC-UIT2 MODBUS PROTOCOL INTERFACE MAPPING FOR NGC-30 SYSTEMS. Firmware versions up to V2.0.X NGC-UIT2 MODBUS PROTOCOL INTERFACE MAPPING FOR NGC-30 SYSTEMS Firmware versions up to V2.0.X INDUSTRIAL HEAT TRACING SOLUTIONS EN-RaychemNGCUIT2Protocol-IM-H57880 06/15 1/32 Contents Section I Introduction

More information

RC802/ B 8E1 Modular Fiber-Optic Multiplexer (Rev. M) User Manual

RC802/ B 8E1 Modular Fiber-Optic Multiplexer (Rev. M) User Manual RC802/804-240B 8E1 Modular Fiber-Optic Multiplexer (Rev. M) User Manual Raisecom Technology Co., Ltd. (04/2005) 1. Cautions Please read the following notices carefully before installing and using the device,

More information

Simplex Panel Interface Guide

Simplex Panel Interface Guide Simplex Panel Interface Guide February 2016 SATEON Software Integrations Simplex Panel Interface Guide Issue 1.0, released February 2016 Disclaimer Copyright 2016, Grosvenor Technology. All rights reserved.

More information

Fire Operator Workstation (Fire OWS) User s Guide

Fire Operator Workstation (Fire OWS) User s Guide Fire Operator Workstation (Fire OWS) User s Guide 1-1 Fire Operator Workstation (Fire OWS) User s Guide Introduction This user s guide details the components, capabilities, and operation procedures of

More information

OPERATOR S MANUAL MODEL AP15/AP15-1/AP15-2 PC-ALARM PANEL

OPERATOR S MANUAL MODEL AP15/AP15-1/AP15-2 PC-ALARM PANEL ap15_2manual04/22/13 Page 1 4/22/2013 1 Serial Number : Option: OPERATOR S MANUAL MODEL AP15/AP15-1/AP15-2 PC-ALARM PANEL Micro Seven, Inc. 1095-K N.E. 25th Hillsboro, OR 97124 U.S.A. phone: 503-693-6982

More information

3D_ISS. Integrated Software System. User Guide Manual

3D_ISS. Integrated Software System. User Guide Manual 3D Digital Design & Development LTD 58/60 Edward Road Tribec House New Barnet EN4 8AZ 020 8440 7060 3D_ISS Integrated Software System User Guide Manual Copyright 2014 3D Digital Design and Development

More information

Metasys Integrator Compu-Aire Application

Metasys Integrator Compu-Aire Application Metasys Connectivity Technical Manual 629.5 Metasys Integrator Section Application Note Issue Date 0496 APPLICATION NOTE Metasys Integrator Compu-Aire Application lntroduction Page 3 Application Details

More information

Installation Manual GalaXy G2 / G3 / GD. o Settings GalaXy o Linking with iprotect o Keymap

Installation Manual GalaXy G2 / G3 / GD. o Settings GalaXy o Linking with iprotect o Keymap Installation Manual GalaXy G2 / G3 / GD o Settings GalaXy o Linking with iprotect o Keymap Publication July 2013, Keyprocessor BV Paasheuvelweg 20 1105BJ Amsterdam, The Netherlands www.keyprocessor.com

More information

TV2 Room Pressure Monitor Quick Start Guide

TV2 Room Pressure Monitor Quick Start Guide TV2 Room Pressure Monitor Quick Start Guide 1. The Care and Use guide for your TV2 Room Pressure Monitor can be downloaded here: www.e2di.com/usersguides.html Please print out the Users Guide. Although

More information

Rev UltraSite User s Guide BCU Supplement

Rev UltraSite User s Guide BCU Supplement 026-1004 Rev 1 09-04-97 UltraSite User s Guide BCU Supplement Computer Process Controls, Inc. 1640 Airport Road Suite #104 Kennesaw, GA 31044 Phone (770) 425-2724 Fax (770) 425-9319 ALL RIGHTS RESERVED

More information

Metasys Integrator Vilter Application

Metasys Integrator Vilter Application Metasys Connectivity Technical Manual 629.5 Metasys Integrator Section Application Note Issue Date 1294 APPLICATION NOTE Metasys Integrator Vilter Application lntroduction Page 3 Application Details *3

More information

Version 1.03 January-2002 USER S MANUAL

Version 1.03 January-2002 USER S MANUAL Version 1.03 January-2002 1 USER S MANUAL 2 Version 1.03 January-2002 System Details CUSTOMER:...... PHONE:... FAX:... INSTALLED BY:...... PHONE:... FAX:... MAINTENANCE & SERVICE:...... PHONE:... FAX:...

More information

Fire System Objects. Introduction Page *3. Engineering *17. Data Base Generation *43

Fire System Objects. Introduction Page *3. Engineering *17. Data Base Generation *43 Metasys etwork Technical Manual 636 Objects Section Technical Bulletin Issue Date 696 Fire System Objects Introduction Page *3 Description *3 Purpose *5 Capabilities *7 Functional Diagram *1 Operator Interface

More information

Monitor Alarms and Events

Monitor Alarms and Events What Are Alarms and Events?, page 1 How are Alarms and Events Created and Updated?, page 2 Which Events Are Supported?, page 5 Set Alarm and Event Management Preferences, page 5 Interpret Event and Alarm

More information

IRIS Touch Firmware Enhancements and Additions from Version to Version

IRIS Touch Firmware Enhancements and Additions from Version to Version Overview IRIS Touch Firmware Enhancements and Additions from Version 1.14.3 to Version 1.19.1 This document details enhancements to the feature set of the IRIS Touch from firmware Version 1.14.3 to Version

More information

Operation Manual Fighter ProVision Software. Version: 0.0 Revision: 1

Operation Manual Fighter ProVision Software. Version: 0.0 Revision: 1 Operation Manual Fighter ProVision Software Version: 0.0 Revision: 1 TABLE OF CONTENTS 1. Introduction 5 2. Software Installation 5 3. PC Users 6 3.1 Introduction 6 3.2 Default Code 6 3.3 Edit PC User

More information

Q-SMART MODBUS KIT. Modbus Protocol & Parameters. Cod EN rev.a ed.08/2018. Q-SMART Software Version AE17

Q-SMART MODBUS KIT. Modbus Protocol & Parameters. Cod EN rev.a ed.08/2018. Q-SMART Software Version AE17 Q-SMART MODBUS KIT Modbus Protocol & Parameters Cod.001085120EN rev.a ed.08/2018 Q-SMART Software Version AE17 Index 1 Modbus Protocol on Q-SMART... 4 1.1 Broadcasting... 4 1.2 Data Protection... 4 1.3

More information

CONTROL UNIT: REFERENCE MANUAL

CONTROL UNIT: REFERENCE MANUAL CONTROL UNIT: REFERENCE MANUAL 1 THE DISPLAY AND REVIEW SCREENS...3 1.1 The Single Bar-graph Display...4 1.2 The View Multiple Devices Display...5 1.2.1 Multiple Bar-graph Display...5 1.2.2 Multiple Device

More information

SmarTemp Control fx 2.0

SmarTemp Control fx 2.0 Digital Timer Interface Installation / Operation Instructions General Thank you for choosing Webasto to meet your heating needs. The Webasto SmarTemp Control fx 2.0 enables you to preset start-up cycles

More information

FL500 Modbus Communication Operating Manual. Order No.: /00. MSAsafety.com

FL500 Modbus Communication Operating Manual. Order No.: /00. MSAsafety.com FL500 Modbus Communication Operating Manual Order No.: 10193214/00 MSAsafety.com 1000 Cranberry Woods Drive Cranberry Township, PA 16066 A Phone 1-800-MSA-2222 Fax 1-800-967-0398 For your local MSA contacts

More information

Metasys Integrator Cleaver-Brooks Application

Metasys Integrator Cleaver-Brooks Application Metasys Connectivity Technical Manual 69. Metasys Integrator Section Application Note Issue Date 0900 APPLICATION NOTE Metasys Integrator Cleaver-Brooks Application lntroduction Page Application Details

More information

Security Escort Central Console Software SE2000 Series

Security Escort Central Console Software SE2000 Series Release Notes Security Escort Central Console Software SE2000 Series Table of Contents 1 Security Escort v2.18.1.0... 2 1.1 Enhancements... 2 1.2 Errors Fixed... 2 1.3 Known Limitations and Restrictions...

More information

SC-F3G User Manual 1.0

SC-F3G User Manual 1.0 SC-F3G User Manual 1.0 Table of Contents 1. Introduction... 3 2. Functions... 3 3. Features... 3 4. Package Contents... 3 5. Device Configuration... 4 6. Status LED signals... 5 7. Before You Start...

More information

System Galaxy Quick Guide

System Galaxy Quick Guide System Galaxy Quick Guide CONFIGURATION AND OPERATION Integrating CCTV with System Galaxy JAN 2019 SG 11.1.0.2 System Galaxy Quick Guide For CCTV Integration Configuration & Operation Information in this

More information

FieldServer Driver - Serial FS Notifier NCA

FieldServer Driver - Serial FS Notifier NCA Driver Version: 1.00 Document Revision: 15 Description FieldServer Driver - Serial FS-8700-98 Notifier NCA The NCA (Network Control Annunciator) Serial driver allows the FieldServer to record data from

More information

Addendum. HART Communication with the FlexSonic Acoustic Detector. 1.1 Rev: 1/

Addendum. HART Communication with the FlexSonic Acoustic Detector. 1.1 Rev: 1/ Addendum HART Communication with the FlexSonic Acoustic Detector 1.1 Rev: 1/15 Table Of Contents Interconnecting the HART Communicator with the Acoustic Detector... 1 HART Device Description Language...

More information

FIRERAY 5000 range USER GUIDE

FIRERAY 5000 range USER GUIDE FIRERAY 5000 range USER GUIDE 0044-003-04 IMPORTANT PLEASE NOTE: The beam path MUST be kept clear of obstructions at all times! Failure to comply may result in the Detector initiating a Fire or Fault signal.

More information

TS400. Operating Manual. Test Station for Microtector II Series (G450/G460)

TS400. Operating Manual. Test Station for Microtector II Series (G450/G460) Operating Manual TS400 Test Station for Microtector II Series (G450/G460) GfG GESELLSCHAFT FÜR GERÄTEBAU MBH KLÖNNESTRASSE 99 44143 DORTMUND, Germany TEL. +49 / (0)2 31 / 5 64 00 0 FAX +49 / (0)2 31 /

More information

Sentient. Downloader Manual D4854

Sentient. Downloader Manual D4854 Sentient Downloader Manual D4854 Dycon Ltd Tel: +44 (0)1443 471 060 Fax: +44 (0)1443 479 374 Cwm Cynon Business Park Mountain Ash CF45 4ER - UK www.dyconsecurity.com sales@dyconsecurity.com TABLE OF CONTENTS

More information

Testing the System. Battery Test. Dialer Test. Fire Drill Test (Code + [#] + 69) One-Man Fire Walk-Test (Code + [#] + 68)

Testing the System. Battery Test. Dialer Test. Fire Drill Test (Code + [#] + 69) One-Man Fire Walk-Test (Code + [#] + 68) F A 1 7 0 0 c Testing the System Battery Test When AC power is present, the FA1700C runs a brief battery test every 60 seconds to determine if there is a battery connected, and runs an extended battery

More information

PBI Manual. Paradox to KNX-BUS Interface

PBI Manual. Paradox to KNX-BUS Interface PBI 64-192 Paradox to KNX-BUS Interface Manual GDS Intelligence in Buildings El. Benizelou 116 Nea Erithrea, 14671 Phone: +30 2108071288 Email: info@gds.com.gr Web: gds.com.gr Contents 1 Device description...

More information

Alarm Client. Installation and User Guide. NEC NEC Corporation. May 2009 NDA-30364, Revision 9

Alarm Client. Installation and User Guide. NEC NEC Corporation. May 2009 NDA-30364, Revision 9 Alarm Client Installation and User Guide NEC NEC Corporation May 2009 NDA-30364, Revision 9 Liability Disclaimer NEC Corporation reserves the right to change the specifications, functions, or features,

More information

ModBus DE-1 INSTALLATION AND USER MANUAL

ModBus DE-1 INSTALLATION AND USER MANUAL ModBus DE-1 INSTALLATION AND USER MANUAL INTESIS Software, SL Distributed by DURAN ELECTRONICA S.L Tomás Bretón 50 28045 MADRID, España duran@duranelectronica.com www.duranelectronica.com 2 2010 DURAN

More information

Products no longer available

Products no longer available Technical data sheet MONICO-.. Turnkey automation station MONICO-.. Forms an efficient fire protection system together with the motorisation sets BF(G)24MP Completely wired controller in matching control

More information

SEC 3500 OI- StatCast RS232 Gas Status Text Broadcast Configuration Manual

SEC 3500 OI- StatCast RS232 Gas Status Text Broadcast Configuration Manual SEC 3500 OI- StatCast RS232 Gas Status Text Broadcast August, 2006 Sensor Electronics Corporation 5500 Lincoln Drive USA (952) 938-9486 Table Of Contents: Intended Audience... 3 Purpose...3 Overview...

More information

User manual. KNXgal. version

User manual. KNXgal. version User manual version 1.3 gal Management alarm control panels Galaxy from bus powered from bus Communication indication on and with Galaxy control panel DIN rail mount (1 modul) Adjustable address on with

More information

Operations Manual TS400. Test Station for G450/G460 Gas Detector

Operations Manual TS400. Test Station for G450/G460 Gas Detector TS400 Test Station for G450/G460 Gas Detector Operations Manual 1194 Oak Valley Dr, Ste 20, Ann Arbor MI 48108 USA (800) 959-0329 (734) 769-0573 www.goodforgas.com GfG Products for Increased Safety Congratulations

More information

GLOBAL. InstallatIon & operation manual

GLOBAL. InstallatIon & operation manual InstallatIon & operation manual INDEX 1. INTRODUCTION... 5 2. FEATURES AND FUNCTIONS 2.1 Reporting Options... 2.2 Interfaces... 2.3 Programming... 2.4 Indicators and Controls...... 6 6 6 6 6 3. INSTALLATION...

More information

Millennium Xtra. Millennium ATMA setup and configuration guide. May Millennium Group, Inc.

Millennium Xtra. Millennium ATMA setup and configuration guide. May Millennium Group, Inc. Millennium Xtra Millennium ATMA setup and configuration guide May 16 2017 Millennium Group, Inc. 16 Tech Circle Natick, MA 01760 P: 508-655-1340 F: 508-651-2902 Millennium ATMA setup and configuration

More information

Universal Monitoring System. Model IMEC8A. User Manual Version 1.10 Software version 2.3.1

Universal Monitoring System. Model IMEC8A. User Manual Version 1.10 Software version 2.3.1 Unit 7/8, Heathrow Causeway Estate, Ariel Way, Hounslow Middlesex, TW4 6JW +44 (0) 208 6302270 www.cpcuk.co.uk Universal Monitoring System Model IMEC8A User Manual Version 1.10 Software version 2.3.1-1

More information

2000 Series. Program Entry Guide. Control Panels

2000 Series. Program Entry Guide. Control Panels 2000 Series EN Program Entry Guide Control Panels 2000 Series Program Entry Guide About This Manual EN 2 About This Manual This guide describes the programming parameters available to the 2000 Series Control

More information

Memcom Emergency Telephone

Memcom Emergency Telephone Memcom Emergency Telephone Installation Guide Ref No. 450 900 (GB) Version 2 + + Simple wiring for quick installation + + Integrated LCD display shows you what you have programmed + + All code based programming

More information

IndigoVision Alarm Panel. User Guide

IndigoVision Alarm Panel. User Guide IndigoVision Alarm Panel User Guide THIS MANUAL WAS CREATED ON 2/21/2017. DOCUMENT ID: IU-AP-MAN002-4 Legal considerations LAWS THAT CAN VARY FROM COUNTRY TO COUNTRY MAY PROHIBIT CAMERA SURVEILLANCE. PLEASE

More information

AK-CS On Board Guide

AK-CS On Board Guide MAKING MODERN LIVING POSSIBLE AK-CS On Board Guide electronic controls & sensors About this guide The AK-CS On Board guide highlights the use of the RMT tool, allowing remote software management. Consult

More information

System description LG 66E-TL11 with time lock function

System description LG 66E-TL11 with time lock function System description LG 66E-TL11 with time lock function Keypad 3125 This TL11-Software is available for the locks: COMBOGARD 6040 -TL11 SAFEGARD SWINGBOLT 6260 -TL11 V1.20 SAFEGARD OVERRIDE 6441M-TL11 With

More information

OPERATING MANUAL. PCC Controller. (PCC-01 and G) [PCC-01 shown]

OPERATING MANUAL. PCC Controller. (PCC-01 and G) [PCC-01 shown] OPERATING MANUAL PCC Controller (PCC-01 and 1-149160G) [PCC-01 shown] www.unipowerco.com 2018 UNIPOWER LLC All Rights Reserved UNIPOWER LLC 3900 Coral Ridge Drive, Coral Springs, Florida 33065, USA sales@unipowerco.com

More information

C&K Software What s New. Commander II Version 3.0 Monitor II Version 3.0 Satellite II Version 1.0

C&K Software What s New. Commander II Version 3.0 Monitor II Version 3.0 Satellite II Version 1.0 C&K Software What s New Commander II Version 3.0 Monitor II Version 3.0 Satellite II Version 1.0 C&K Software PC-based receiver with monitoring features Windows-based Remote programming software (Commander

More information

Other trade names mentioned in this document may be registered trademarks or trademarks of respective product manufacturers or vendor products.

Other trade names mentioned in this document may be registered trademarks or trademarks of respective product manufacturers or vendor products. Attention! Read this user manual carefully. Representative of the company installing the alarm system will explain which security module SP231 functions needs to be activated to ensure proper security

More information

Alarms for the Cisco ISA 3000

Alarms for the Cisco ISA 3000 About s This chapter gives an overview of the alarm system in the ISA 3000, and also describes how to configure and monitor alarms. About s, on page 1 Defaults for s, on page 3 Configure s, on page 3 Monitoring

More information

DIAMOND II. DARM Delayed Alarm Reporting/Masking. Manual Number AV Revision - A.1 September 3, 2004

DIAMOND II. DARM Delayed Alarm Reporting/Masking. Manual Number AV Revision - A.1 September 3, 2004 Manual Number AV-137622 Revision - A.1 September 3, 2004 DIAMOND II DARM Delayed Alarm Reporting/Masking 791 Park of Commerce Boulevard Suite 100 Boca Raton Florida 33487 www.ge-security.com DIAMOND II

More information

SimpleComTools, LLC 1

SimpleComTools, LLC 1 COM1000-SNMP s Simple Network Management Protocol (SNMP) is a popular network management tool. Traditionally, SNMP was designed and used to gather statistics for network management and capacity planning.

More information

GDC 087R Issue 1 - May Installation and Operation UAS Network/Dropside Interface Unit Model NIU/DIU 7624.

GDC 087R Issue 1 - May Installation and Operation UAS Network/Dropside Interface Unit Model NIU/DIU 7624. GDC 087R707-001-01 Issue 1 - May 1998 Installation and Operation UAS 7000 Network/Dropside Interface Unit Model NIU/DIU General DataComm Manual Revision History Shown below is a chronological listing of

More information

TECOM SYSTEMS NETWORK MASTER

TECOM SYSTEMS NETWORK MASTER TECOM SYSTEMS NETWORK MASTER The Tecom Network Master is a cost effective, Dialler Receiver and Direct Line Network Master combined in a single modular unit. HARDWARE The unit consists of a 3RU, 19 inch

More information

Operation Manual. MicroTech Remote Monitoring and Sequencing Panel. for Reciprocating and Screw Chillers

Operation Manual. MicroTech Remote Monitoring and Sequencing Panel. for Reciprocating and Screw Chillers Operation Manual Bulletin No. OM 118 June 1995 Part No. 573932Y-01 MicroTech Remote Monitoring and Sequencing Panel for Reciprocating and Screw Chillers [Photo of panel only] For Use With McQuay Models

More information

Follett Performance Plus

Follett Performance Plus Follett Performance Plus touchscreen user guide The next level of control in undercounter refrigeration Controller Operation - Performance Plus touchscreen Use and care of the LCD Performance Plus touchscreen

More information

Setup Instructions. This manual is only valid for A36D/TPSD Chargers. equipped with a 341S control card with P341S0012 or P341S0013 software

Setup Instructions. This manual is only valid for A36D/TPSD Chargers. equipped with a 341S control card with P341S0012 or P341S0013 software La Marche Manufacturing Company www.lamarchemfg.com DNP 3.0 Serial (RS232/RS485) and Ethernet (TCP/IP) SCADA Interface for A36D & TPSD Chargers with S2A-341S and S2A-383S communication cards. Option 21P,

More information

1 Application Note Bosch Security Sys Sy tems m Bosch Security Systems Smart Safety Link -

1 Application Note Bosch Security Sys Sy tems m Bosch Security Systems Smart Safety Link - 1 Application Note Public Address Smart Safety Link PAVIRO and FPA configuration Bosch Security Systems Public Address Bosch Security Systems Public Address Application Note Smart Safety Link - PAVIRO

More information

Ambient Temperature/ Relative Humidity & Dew Point Temperature Sensors to USB Output. Model LFS108B

Ambient Temperature/ Relative Humidity & Dew Point Temperature Sensors to USB Output. Model LFS108B Ambient Temperature/ Relative Humidity & Dew Point Temperature Sensors to USB Output Model LFS108B Copyright 2018 - LLC. All rights reserved. Table of Contents Quick Start... 3 1- Introduction... 4 2-

More information

User manual. KNXpar. version

User manual. KNXpar. version User manual version 1.3 KNXpar Management alarm control panels Paradox from KNX bus Powered from KNX bus Communication indication on KNX and with Paradox control panel DIN rail mount (1 module) Adjustable

More information

Smoke Detector and Siren. Manual

Smoke Detector and Siren. Manual Smoke Detector and Siren Manual 004001 Smoke Detector and Siren Manual Quick Start... 2 Product Description... 2 Installation Guidelines... 3 Behavior within the Z-Wave Network... 3 Operating the Device...

More information

Alarm handling by SMS in ALERT

Alarm handling by SMS in ALERT Micromedia International Alarm handling by SMS Author: Jens Eberle Pages : 9 Company: Micromedia International Date : 29/10/2013 Version : 1.1 Réf. : Alarm Handling by SMS.docx [Commentaires ] Alarm handling

More information

Farm Hand CCU 111 / CCU 10R. Manual for use and maintenance. Farm Hand. Climate Controller. HC/MMA/UmGB /13 rev 1.

Farm Hand CCU 111 / CCU 10R. Manual for use and maintenance. Farm Hand. Climate Controller. HC/MMA/UmGB /13 rev 1. Manual for use and maintenance Farm Hand CCU 111 / CCU 10R Farm Hand Climate Controller HC/MMA/UmGB-2043-01/13 rev 1.8 P/N: 110131 Farm Hand CCU 111, Farm Hand CCU 10R Manual for use and maintenance Revision:

More information

DiaLog Elite. Quick Reference Guide. Remote Monitoring, Control and. Alarm Notification System. # Enter. 1 Prog. 2 Run. 5 SpkrPh. Ack. Arm.

DiaLog Elite. Quick Reference Guide. Remote Monitoring, Control and. Alarm Notification System. # Enter. 1 Prog. 2 Run. 5 SpkrPh. Ack. Arm. DiaLog Elite 1 Prog Remote Monitoring, Control and 2 Run Alarm Notification System 5 SpkrPh 0 Status # Enter Quick Reference Guide Ack Clear Arm Reset Disarm Bksp Home Antx, inc. 2008 RUN Mode Commands

More information

Alarm Panel [ PRELIMINARY HARDWARE MANUAL ] USER MANUAL. v1.0a. May 7, 2008 D-OC-UM

Alarm Panel [ PRELIMINARY HARDWARE MANUAL ] USER MANUAL. v1.0a. May 7, 2008 D-OC-UM Alarm Panel USER MANUAL [ PRELIMINARY HARDWARE MANUAL ] Visit our website at www.dpstelecom.com for the latest PDF manual and FAQs. May 7, 2008 D-OC-UM085.07010 v1.0a Revision History April 28, 2008 May

More information

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers. ModSync Sequencing System Installation & Operation Manual For use with Fulton Steam Boilers. Revision 3.0 8/21/2008 - 2 - Table of Contents Introduction Page 4 Features Page 4 Sequence of Operation Page

More information

FlameGard 5 MSIR HART

FlameGard 5 MSIR HART FlameGard 5 MSIR HART Multi-Spectral Infrared Flame Detector HART Communication with the FlameGard 5 Multi-spectral Infrared Detector The information and technical data disclosed in this document may be

More information

IntesisBox BACnet/IP Server - Notifier ID3000 series

IntesisBox BACnet/IP Server - Notifier ID3000 series IntesisBox Server - Notifier ID3000 series Gateway for integration of Notifier ID3000, ID3002, ID50 and ID60 fire panels into enabled control systems. Integrate your Notifier fire panels into your BACnet

More information

BOSCH GV4 Alarm Panel

BOSCH GV4 Alarm Panel System Galaxy Quick Guide CONFIGURATION AND OPERATION BOSCH GV4 Alarm Panel SG 10.2 (or later) NOV 2012 This is a Galaxy Product Interface Guide. Information in this document is subject to change without

More information

Operations Manual TS400. Test Station for G450/G460 Gas Detector

Operations Manual TS400. Test Station for G450/G460 Gas Detector TS400 Test Station for G450/G460 Gas Detector Operations Manual 1194 Oak Valley Dr, Ste 20, Ann Arbor MI 48108 USA (800) 959-0329 (734) 769-0573 www.gfg-inc.com GfG Products for Increased Safety Congratulations

More information

Metasys Integrator Liebert Application

Metasys Integrator Liebert Application Application Note Issue Date May, 00 Metasys Integrator Liebert Application lntroduction Application Details Component Requirements 0 Vendor Contact Information Design Considerations Cable Connections Cable

More information

RAy SNMP. Application notes.

RAy SNMP. Application notes. Application notes. RAy SNMP. version 1.0 12/29/2017 RACOM s.r.o. Mirova1283 59231 Nove MestonaMorave CzechRepublic Tel.: +420565659 511 Fax: +420565659 512 E-mail: racom@racom.eu www.racom.eu Table of

More information

User s Guide. SUB-MA7240O-0001.OG.Solution doc. Created: 6/05/03. Last Updated: 23/09/03. MA7240AO-0001 Version 1.0

User s Guide. SUB-MA7240O-0001.OG.Solution doc. Created: 6/05/03. Last Updated: 23/09/03. MA7240AO-0001 Version 1.0 User s Guide SUB-MA7240O-0001.OG.Solution40-111.doc Created: 6/05/03 Last Updated: 23/09/03 MA7240AO-0001 Version 1.0 2 Table Of Contents User List...6 Quick Reference..7 Features...7 Keypad User's Guide...8

More information

Dryer Controller M720

Dryer Controller M720 User Manual Dryer Controller M720 Hardware version 2.00 Software version 2.00 Manual M720 Dryer controller Page 1 of 60 Document history Preliminary version: - Created in April, 2009 Hardware Version 2.00,

More information

Release Notes for Version 7.05 January 2007

Release Notes for Version 7.05 January 2007 Control Panels D9412GV2/D7412GV2 Release Notes for Version 7.05 January 2007 Trademarks Molex is a registered trademark of Molex Incorporated. 1.0 Requirements Table 1: Required Handlers D5200 Handler

More information

TV2 Clean Room Monitor

TV2 Clean Room Monitor TV2 Clean Room Monitor 1. The Care and Use guide for your TV2 Clean Room Monitor can be downloaded here: www.e2di.com/usersguides.html Please print out the Users Guide. Although you should use the Users

More information

FieldServer FS Secutron

FieldServer FS Secutron FieldServer FS-8700-72 Secutron Driver Manual (Supplement to the FieldServer Instruction Manual) APPLICABILITY & EFFECTIVITY Effective for all systems manufactured after November 2015 Kernel Version: 1.02

More information

RESET + Password Enter (During Auto Speed Procedure) Maintenance Timeout or after TEST + RESET + DISABLE (No Need for Device to Initialize)

RESET + Password Enter (During Auto Speed Procedure) Maintenance Timeout or after TEST + RESET + DISABLE (No Need for Device to Initialize) FAAST LT FIRE ALARM ASPIRATION SENSING TECHNOLOGY ADVANCED SET-UP AND CONTROL GUIDE CONTENTS Introduction....1 The FAAST LT Functional State Diagram....1 Password Procedure (to enter Maintenance Mode)

More information

User Manual. Dryer Controller M720

User Manual. Dryer Controller M720 User Manual Dryer Controller M720 Hardware version 1.00 Software version 1.00 Preliminary version Manual M720 Dryer controller Page 1 of 42 Document history Preliminary version: - Created in April, 2009

More information

Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE

Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE General Description This guide provides a summary for installing and configuring the Centaur TM Cube Slave Alarm Signalling Equipment

More information

ViewMatrix. Software for Online Monitoring & Control of Matrix2000 Conventional Fire Alarm Panels. Version: 2.0 Revision: 0.1

ViewMatrix. Software for Online Monitoring & Control of Matrix2000 Conventional Fire Alarm Panels. Version: 2.0 Revision: 0.1 ViewMatrix Software for Online Monitoring & Control of Matrix2000 Conventional Fire Alarm Panels Version: 2.0 Revision: 0.1 CONTENTS 1. Introduction...3 2. Keyboard...5 2.1 POWER indication - Normal Operation...5

More information

Series Digital Controller Instruction Sheet

Series Digital Controller Instruction Sheet 216/3/11 Series Digital Controller Instruction Sheet Thank you very much for purchasing DELTA DTC Series Temperature Controller. Please read this instruction sheet before using your DTC series to ensure

More information