SCHEME OF TESTING AND INSPECTION FOR CERTIFICATION OF PORTABLE FIRE EXTINGUISHER- PERFORMANCE AND CONSTRUCTION AS PER IS 15683: 2006
|
|
- Gwendolyn Dalton
- 5 years ago
- Views:
Transcription
1 SCHEME OF TESTING AND INSPECTION FOR CERTIFICATION OF PORTABLE FIRE EXTINGUISHER- PERFORMANCE AND CONSTRUCTION AS PER IS 15683: LABORATORY 1.1 A Laboratory shall be maintained which shall be suitably equipped and staffed, where tests shall be carried out in accordance with the methods given in the specification. 1.2 All testing apparatus / measuring instruments shall be periodically checked and calibrated and records of such checks/calibration shall be maintained. 2. TEST RECORDS 2.1 All records of tests and inspection shall be kept in suitable forms approved by the Bureau. 2.2 Copies of any records and other connected papers that may be required by the Bureau shall be made available at any time on request. Note: The existing forms etc. as being maintained by the manufacturers may be retained. These forms, however, shall contain all the information required for operating this scheme of Testing and Inspection. 3. QUALITY CONTROL 3.1 It is recommended that, as for as possible, Statistical Quality Control (SQC) methods may be used for controlling the quality of the product during production as envisaged in this scheme. [See IS 397(part 1) to IS 397 (part 4)]. 3.2 In addition, effort should be made to gradually introduce a Quality Management System in accordance with IS/ISO 9001 to all activities of the organization. 4. STANDARD MARK 4.1 The Standard Mark as given in column (1) of the first schedule of the license, shall be marked/applied indeligibly by stenciling/screen printing/transfix labels/engraving on each fire extinguisher provided always that the item to which this mark is thus applied conforms to every requirement of the specification.
2 In case the mark is applied by engraving/punching, it shall be applied in such a manner that it does not impair the strength and dimensional requirements of the fire extinguisher in anyway. 4.2 Marking - In addition, fireextnguisher shall be clearly and indeligibly marked by means as stated above (Ref. Clause 10.2 of IS 15683:2006 also) with the followinga) Name or Trade mark of manufacturer b) BIS License number (CM/L- xxxxxxx) c) Type of media of fire extinguisher d) Base material and its percentage for Powder e) Model number e) Rating and classification of fire extinguisher f) Acceptable to use at temperature from... to... o C g) Empty mass in kg h) Nominal full mass in kg/ Gross mass with tolerance or Min & max gross mass in kg i) Year of manufacture j) Sequential serial number k) following statement as applicable l) For rechargeable extinguishers: Recharge immediately after any use m) For disposable extinguishers ; Discard immediately after any use n) Operating, recharging, inspection and maintenance instructions (in the form of an etched or embossed metal name plates or band or an acceptable pressure sensitive nameplates or by silk screening of paint. Operating instructions also to be shown by pictorial view. 5. LEVELS OF CONTROL 5.1. The Tests as indicated in the Table 1 and at the levels of controls specified therein shall be carried out on the whole production of the factory covered by this scheme and appropriate records and charts maintained in accordance with clause 2 above. All the production which conforms to this Indian Standard and covered by this license shall be marked with Certification Mark of the Bureau. 5.3 CONTROL UNIT For the purpose of this scheme a control, shall be taken as 100 or part there of, extinguishers of the same type/classification and capacity manufactured continuously or on consecutive days from same consignment of inputs (material, machine and man power in case of manual welding employed) For Plastic components, a control may be taken as the quantity manufactured continuously on same machine using same source and consignment of raw material, with same mix of ingredients, if any used.
3 5.3.3 For Pressure gauges and Indicators- Control Unit may be taken as the quantity of gauges and indicators received from same supplier / manufacturer, of same size, model, and material On the basis of tests and inspection results, decision regarding conformity or otherwise of the control to a given requirement of the specification shall be made When any sample fails in respect of a given requirements the material of entire control may be suitably corrected and subject twice the number of samples to test for all requirements again, and the control shall be accepted for certification marking only when the re-processed material conforms to all the requirements. If further failure occurs in any of the requirements, the entire lot/control shall not be marked. Alternately, on the discretion of manufacturer all material of the control may not be marked in the first instance of failure Records of such failure and reprocessing and retesting shall be maintained. 5.4 PROCESS CONTROL In respect of all other clauses of the specification and at all stages of production, the factory shall maintain appropriate control & checks to ensure that their product conforms to the various requirements of the specification. 6. REJECTIONS 6.1 A separate record shall be maintained giving information relating to the rejection of the production not conforming to the requirements of the specification and the method of its disposal. Such material shall in no circumstances be stored together with that conforming to the specification. 7. SAMPLES 7.1 The licensee shall supply, free of charge, the samples required in accordance with the Bureau of Indian Standards (Certification) Regulations, 1988, as subsequently amended, from the factory or godowns. The Bureau shall pay for the samples taken by it from the open market. 8. REPLACEMENT 8.1 Whenever a complaint is received soon after the goods with Standard Marks have been purchased and used, and if there is adequate evidence that the goods have not been misused, defective goods or their components are replaced or repaired free of cost by the licensee in case the complaint is proved to be genuine and the warranty period (where applicable) has not expired. The final authority to judge the conformity of the product to the Indian Standard shall be
4 with the Bureau. The firm shall have own complaint investigation system as per IS/ISO In the event of any damages caused by the goods bearing the Standard Mark, or Claim being filed by the Consumers against BIS Standard Mark and not Conforming to the relevant Indian Standard, entire liability arising out of such non conforming product shall be of licensee and BIS shall not in any way be responsible in such cases. 9. STOP MARKING 9.1 The marking of the product shall be stopped under intimation to the Bureau if, at any time, there is some difficulty in maintaining the conformity of their product to the specification, or the testing equipment goes out of order. The marking may be resumed as soon as the defects are removed under intimation to Bureau. 9.2 The marking of the product shall be stopped immediately if directed to do so by Bureau for any reason. The marking may then be resumed only after permission by the Bureau. The information regarding resumption of markings shall also be sent to the Bureau. 10. PRODUCTION DATA 10.1 The licensee shall send to BIS as per the enclosed Proforma-1 to be authenticated by a Chartered Accountant, a statement of quantity produced, marked and exported by them and the trade value thereof at the end of each operative year of the licence.
5 SCHEME OF TESTING AND INSPECTION FOR PORTABLE FIRE EXTINGUISHERS- PERFORMANCE AND CONSTRUCTION AS PER IS 15683: 2006 Table 1 Levels of Control Levels of Control Sl. No. of Frequency Remarks No. Test sample Requirements clause References 1 Extinguishing media i) Carbon di IS 15683, One Each Manufacturer s oxide IS consignment certificate may be accepted. Firm to arrange for testing of samples at an ii) Clean agents IS 15683, -do- -do- independent IS approved lab once in six month. *Or as per supplier standard of Clean agent iii) Powders IS 15683, -do- -do- IS no.s as IS 4308, applicable IS 14609, IS 4861 iv) Foam IS 15683, -do- -do- IS no.s as agents IS 4989, applicable ISO Propellants 5.2 IS One Three As above months
6 3 Filling 5.3 IS requirements i) Fill density IS One Each control Firm to declare fill density as per the Standard of clean agents. ii) Filling IS One Each control tolerance iii) Capacities IS One Each control 4 Test Pressure 6 IS i) Test pressure 6.1 IS All Each control ii) Min Burst 6.2 IS One Each control Pressure 5 Gen Operating 7 IS performance requirements i) Operating 7.1 IS Firm to declare temperatures any one of the temperature ranges. ii) Min. effective 7.2.1, IS One Each control For Class A discharge time IS One Each control For class B iii)bulk range of IS One Each control discharge Resistance to 7.3.1, IS One Once in Type Test temp changes IS three months Retention of charge
7 a) Routine IS All Each control checks b) Retention of IS One Each control charge following partial discharge c) Long-term 7.4.3, IS One Once in Six Type Test leakage test months Mechanical 7.5 IS Type Test resistance test a) Resistance IS One Once in Type Test to impact three months b)resistance to IS One Once in Type Test Vibrations three months Resistance to 7.6 IS Type Test corrosion a) External IS Two One year One sample each corrosion of two different sizes (or of one size if different sizes not manufactured) from same type (same extinguishing media). All types to be covered in a year. However, all sizes of different types to be covered in three years. b) Internal IS Two One year As above. corrosion (for water based media and gaseous extinguishers) Tapping test 7.7 IS One Three All sizes and types
8 months to be covered in two years. Intermittent 7.8 IS One Three As above. discharge test months 6 Performance 8.1.to IS One One year All sizes, types requirement for 8.5 and extinguishing Test Fires media to be covered in a year. The fire rating shall be declared by the manufacturer. Preferably be done in presence of BIS inspecting officer at least once a year. If test facility does not exists, test shall be done in a BIS recognized Lab. 7 Electrical 8.6 IS One Six months Applicable to conductivity of water based extinguisher extinguishers that discharge are marked as suitable for use on energized electrical equipment. All sizes to be tested once in six months.
9 8 Construction Requirements i) High 9.1 IS 15683, Pressure *IS 7285, extinguishers *IS15660, *IS 4947 ii) Low pressure extinguishers General IS requirements to Determination IS of max service pressure Burst test 9.2.2, IS Crushing Test IS (Type Test) Permanent IS Volumetric expansion test (Type Test) Pressure Cyclic IS Test (Type Test) Welded low IS carbon steel cylinder i) Cylinder and IS 15683
10 All Each control *IS number as applicable. For Steel body. For Aluminium body. For Gas cartridge. All Each control Three Once in All sizes and Three types. months One Three Each control Each control May be carried out on the same cylinder taken for burst test. One Each control For high pressure cylinder only. No further testing is required if material is ISI marked and accompanied by a Test Certificate from supplier. Two Every 5 th Start from 1st control control and whenever there is change in material source One Each Firm may get the
11 filler material to consignment material tested at independent BIS approved lab, if in house facilities are not available. ii) Cylinder IS All Each control thickness Stainless steel IS cylinders i) Material, IS One Each Firm may get the domes and to consignment material tested at bottoms independent BIS approved lab, if in ii) Cylinder IS All Each control house facilities are thickness not available. Aluminium IS cylinders i) Material IS All Each control Firm may get the material tested at ii) cylinder IS All Each control independent thickness approved lab, if in house facilities are not available. Carrying handle to IS All Each control Mounting to IS All Each control & 9.4.5, i) Mounting 9.4.3, IS Two Each control bracket strength Caps, Valves to IS All Each control and Closures & i) Burst test- for IS One Each control above Safety devices 9.6.1, IS Two Each control Each control Hydrostatic IS All pressure test
12 9 Requirement Whenever for plastics provided components i) General IS All Each control requirements to ii) Burst , IS Three Each control For normally Strength 9.2.2, pressurized & non pressurized components. iii) Air-oven , IS Three Each control ---- do --- ageing 9.2.2, iv) Ultraviolet 9.8.3, IS Six Each control light exposure v) Impact 9.8.4, IS Four Each control Two with and two resistance , without the safety , locking device engaged vi) Test for 9.8.6, IS Three One year or For water based Exposure to 7.5 whenever extinguishing extinguishing source is media only media changed 10 Hose 9.9 IS Two Each control assemblies 11 Method of 9.10, IS One Each control Test may be operation 7.5 combined with min effective discharge time and bulk range of discharge test 12 Safety locking 9.11 IS devices i) Release of IS Two Each control safety device
13 ii)breaking test IS Each control for tamper indicator iii) General , IS Two Each control requirements , , Requirements 9.12 IS For Stored for Pressure Pressure type gauges and extinguishers Indicators i) General IS All Each control ii) Calibration IS All Each control Calibration test certificate from recognized laboratory may be considered. iii) Burst IS One One Gauge used for strength test hundred or Over Pressure test part there off (clause ) from same may be used. source iv) Over IS One As above pressure test v) Water , IS One As above All sizes of resistance test pressure gauges to be tested. vi) Leakage test IS Six month Testing may be done at independent reputed lab.
14 vii) Plastic , IS One components 9.8 Three hundred (pressure gauges) or part there off 14 Dip-Tubes and 9.13 IS Each control For water based Filters All extinguishers 15 Test for Horns 9.14 IS One Each control 1) For CO 2 extinguishers. 2) Test may be combined with min effective discharge time and bulk range of discharge 16 Colour for 10.1 IS All Each control extinguisher IS 5 body IS Marking , IS All Each control Fig 5 18 Operating IS All Each control Instructions
15 19 Code Symbols , IS All Each control Fig 6 20 Recharging IS All Each control Instructions 21 Inspection 10.3 IS All Each control Instructions 22 User Manual 11 IS All Each control To be provided and Service with each Manual Extinguisher PDF to Word
BUREAU OF INDIAN STANDARDS CENTRAL MARKS DEPARTMENT-III
BUREAU OF INDIAN STANDARDS CENTRAL MARKS DEPARTMENT-III Our Ref: CMD-III/16:15683 02/04/2013 Subject: Implementation of Modified Scheme of Testing and Inspection Doc: STI/15683/2, as per :2006 for the
More informationBUREAU OF INDIAN STANDARDS ( CENTRAL MARKS DEPARTMENT-III ) Our Ref: CMD-III/16:
BUREAU OF INDIAN STANDARDS ( CENTRAL MARKS DEPARTMENT-III ) Our Ref: CMD-III/16:2878 03-12-2007 Subject: Implementation of Amendment No 4 August 2007 to IS 2878:2004 For Fire Extinguishers, Carbon Dioxide
More informationक द र य म हर व भ ग III
क द र य म हर व भ ग III हम र स दभभ क न द र य म ह व भ ग 3/16: IS 16018 14 11 2017 ग षय म ह: IS 16018 : 2012 क अनवप लन तव एस ट आई 1. इस उपर क त व षय क स दभभ प र प त ह 2. सक षम प र ध क र न उपर क त एस ट आई
More informationFire fighting Portable fire extinguishers Performance and construction
Provläsningsexemplar / Preview INTERNATIONAL STANDARD ISO 7165 Third edition 2017-07 Fire fighting Portable fire extinguishers Performance and construction Lutte contre l incendie Extincteurs portatifs
More informationTechnical Data Sheet No. JS-SM-40 DOCUMENT TITLE 2.0 LITRE STORED PRESSURE WET CHEMICAL FIRE EXTINGUISHER
PAGE: ISSUE: DATE: of A 00 07285 DOCUMENT TITLE 2.0 LITRE STORED PRESSURE WET CHEMICAL FIRE EXTINGUISHER MODELS: R2WC 0 07285 ISSUE A FIRST RELEASE NEW DOCUMENT WJJ LRL LHG REV DATE REVISION DESCRIPTION
More informationDEPARTMENT OF LICENSING AND REGULATORY AFFAIRS DIRECTOR S OFFICE GENERAL INDUSTRY SAFETY STANDARDS PART 8. PORTABLE FIRE EXTINGUISHERS
DEPARTMENT OF LICENSING AND REGULATORY AFFAIRS DIRECTOR S OFFICE GENERAL INDUSTRY SAFETY STANDARDS (By authority conferred on the director of the department of licensing and regulatory affairs by sections
More information0.4 In the preparation of this standard, assistance has been derived from the following standards:
FOREWORD 0.1 Formal clauses will be added later. 0.2 The committee identified IS 10617(Pt 1), IS 10617(Pt 2) and IS 10617(Pt 3) for the first revision in the light of CFC free/hfc refrigerants and need
More informationIGS-M-SF-01(0) IGS. Iranian Gas Standards. CO2 Fire Extinguisher, Portable Type
APPROVED 1388 IGS Iranian Gas Standards!" CO2 Fire Extinguisher, Portable Type. Fax:(9821)-8131-5679 3 4567 89:;?@8>: A;BC=D7 4EF< G@H 4I JKL 89:;M A8N=> OI http://igs.nigc.ir/igs igs@nigc.ir Table
More informationARKANSAS FIRE PROTECTION LICENSING BOARD ACT 743 OF 1977
ARKANSAS FIRE PROTECTION LICENSING BOARD ACT 743 OF 1977 As Amended July 1, 1999 20-22-601. LEGISLATIVE INTENT FIRE PROTECTION LICENSING BOARD It is the purpose and intent of this subchapter to provide
More informationGUILFORD COUNTY SCHOOLS
GUILFORD COUNTY SCHOOLS Fire Extinguisher Plan Policy In accordance with the regulations established by the United States Department of Labor pursuant to the Occupational Safety and Health Act and the
More informationGovernment of Bermuda Department of Maritime Administration BERMUDA SHIPPING NOTICE
Government of Bermuda Department of Maritime Administration 2015 028 BERMUDA SHIPPING NOTICE Maintenance, Testing and Inspection of Portable Fire Extinguishers Ref: SOLAS 74/88 as amended, Regulation II-2
More informationFire fighting Portable fire extinguishers Performance and constructionfire fighting Portable fire extinguishers Performance and construction
PRIVATE CIRCULATION FSH/2_14_0006 For comment/vote - Action Due Date: 2014/02/14 Annex A INTERNATIONAL STANDARD ISO 7165 Formatted: Font: 10 pt, Not Bold, (Asian) Korean Second edition 2009-03-15 Fire
More informationSOUTH AFRICAN NATIONAL STANDARD
ISBN 978-0-626-23127-9 SOUTH AFRICAN NATIONAL STANDARD Portable refillable fire extinguishers Published by SABS Standards Division 1 Dr Lategan Road Groenkloof Private Bag X191 Pretoria 0001 Tel: +27 12
More informationGuide to Membership Assessments
Issue 10 July 2008 Guide to Membership Assessments 1. Introduction This guide is intended to assist companies in preparing for an assessment visit by SELECT. It supplements the SELECT Assessment Criteria
More informationModel Policy On Portable Fire Extinguishers (Ontario Version)
Model Policy On Portable Fire Extinguishers (Ontario Version) Every workplace needs a policy ensuring the appropriate selection, use, storage and maintenance of fire extinguishers. OHS managers in any
More informationTechnical Data Sheet No. JS-SM-33 DOCUMENT TITLE. 2.0kg ABE TYPE STORED PRESSURE DRY POWDER PORTABLE FIRE EXTINGUISHER MODEL: R2.
PAGE: ISSUE: DATE: of A 00 0745 DOCUMENT TITLE 2.0kg ABE TYPE STORED PRESSURE DRY POWDER PORTABLE FIRE EXTINGUISHER MODEL: R2.0ABE O 0745 ISSUED FOR USE AS ISSUE A WJJ LRL LHG REV DATE REVISION DESCRIPTION
More informationFlammable liquids, gasoline, oil etc. Advantages. 21 B. Ø 920 mm 21 B. Ø 920 mm
1370 14133 14133 Powder Wheeled Fire Extinguisher kg 25 Approved EN 166-1:200, Marina MED, higest rate achieved - A IVB C CSI Certificate MED/0497/126/09 Organic solid materials, wood rubber, textiles
More informationService Requirements SEMI- ANNUAL ANNUALLY OTHER REF. REQUIREMENT
58 Fire protection equipment requires care and maintenance at scheduled intervals to assure it will operate properly and safely when needed. Only personnel who are trained and qualified to maintain the
More informationC-NRPP Quality Assurance Guidance for Radon Test Devices
C-NRPP Quality Assurance Guidance for Radon Test Devices Table of Contents: 1. Purpose 2. Definitions 3. Quality Assurance Plan 4. Calibration 5. Spikes/Performance Tests 6. Duplicates 7. Blanks 8. Cross-Checks
More informationStatement of Policy. Fire Extinguisher Use Policy #: SMS-041
Statement of Policy Fire Extinguisher Use Policy #: SMS-041 Controlling Office: Director of Health, Safety, Education and Training Effective Date: May 1, 2013 Applies to CAMTS: Ninth Edition 04.02.01-E
More informationCO-ORDINATION OF NOTIFIED BODIES PPE Regulation 2016/425 RECOMMENDATION FOR USE
CO-ORDINATION OF NOTIFIED BODIES PPE Regulation 2016/425 PPE-R/00.017 Version 2 RECOMMENDATION FOR USE Number of pages: 5 Approval stage : Approved on : Origin : Horizontal Committee, C2D Ad hoc group
More informationAttachment 1. to ClassNK Technical Information No.TEC-0764 Malta Maritime Authority Date Revised 28 August 2008 Page 1 of 10 This Administration Requi
Subject Periodical Maintenance, Inspection and Testing for Fire Protection Systems, and Appliances and Compressed Gas Cylinders onboard Maltese Flagged Vessels (Partly Amended) To whom it may concern Technical
More informationBMA INFORMATION BULLETIN No. 97 FIRE FIGHTING EQUIPMENT
BMA INFORMATION BULLETIN No. 97 FIRE FIGHTING EQUIPMENT Guidance and Instructions for Ship-owners, Managers, Masters, Bahamas Recognised Organisations and Bahamas Approved Nautical Inspectors Note: This
More informationExtinguishers. Commercial Industrial High rise buildings
Commercial Industrial High rise buildings Extinguishers Design, Supply, Installation, Testing, Commissioning, Maintenance, and Service of Firefighting and Fire Protection Systems Think fire protection......thank
More informationIMO. Resolution A.951(23) Adopted on 5 December 2003 (Agenda item 17) IMPROVED GUIDELINES FOR MARINE PORTABLE FIRE EXTINGUISHERS
INTERNATIONAL MARITIME ORGANIZATION E IMO ASSEMBLY 23rd session Agenda item 17 A 23/Res.951 25 February 2004 Original: ENGLISH Resolution A.951(23) Adopted on 5 December 2003 (Agenda item 17) IMPROVED
More informationCERTIFICATION SAFETY & BEYOND
CERTIFICATION SAFETY & BEYOND Ferhun Emeksiz & R.M ( Max) Bradbury Client Manager & Fire Products Program Manager Global-Mark Pty Ltd Content Product Certification Understanding the framework Fundamental
More informationTechnical Specification For Design and supply of Water Mist cum CAFS (Compressed Air Foam System) Backpack Fire Fighting System
Technical Specification For Design and supply of Water Mist cum CAFS (Compressed Air Foam System) Backpack Fire Fighting System pg. 1 INTRODUCTION : HPCL is in the process of procurement of Water mist
More informationRULES OF DEPARTMENT OF COMMERCE AND INSURANCE DIVISION OF FIRE PREVENTION CHAPTER FIRE EXTINGUISHERS TABLE OF CONTENTS
RULES OF DEPARTMENT OF COMMERCE AND INSURANCE DIVISION OF FIRE PREVENTION CHAPTER 0780-02-14 FIRE EXTINGUISHERS TABLE OF CONTENTS 0780-02-14-.01 Definitions 0780-02-14-.09 Restrictions 0780-02-14-.02 Standards
More informationTECHNOSKLO Ltd. Držkov
TECHNOSKLO Ltd. Držkov Distillation apparatus for producing of distilled water TYPE DP 4000 Operating manual TECHNOSKLO Ltd. 468 24 Držkov 135 Czech Republic tel.: 00420 483 346 403 fax: 00420 483 385
More informationFINAL DRAFT UGANDA STANDARD First Edition 2008-mm-dd
FDUS ISO 11602-1 FINAL DRAFT UGANDA STANDARD First Edition 2008-mm-dd Fire protection Portable and wheeled fire extinguishers Part 1: Selection and installation Reference number FDUS ISO 11602-1:2000 UNBS
More informationFIRE EXTINGUISHER SERVICING & MAINTENANCE INSTRUCTIONS
BRITANNIA RANGE FIRE EXTINGUISHER SERVICING & MAINTENANCE INSTRUCTIONS Cartridge Operated Water Based Models Page 1 of 5 SPINTRO REV 6 October 2017 PROCEDURES FOR SERVICING THE BRITANNIA RANGE OF HAND
More informationMERAMEC VALLEY R-III SCHOOL DISTRICT 126 North Payne Street Pacific, MO
MERAMEC VALLEY R-III SCHOOL DISTRICT 126 North Payne Street Pacific, MO 63069 636-271-1400 REQUEST FOR PROPOSAL FIRE EXTINGUISHER/KITCHEN HOOD INSPECTIONS FOR ADDITIONAL INFORMATION CONTACT: Joel Cracchiolo,
More information- Check Test Methodology for Tumble Dryers Energy Label & Ecodesign -
- Check Test Methodology for Tumble Dryers Energy Label & Ecodesign - Guidelines and procedures on how to perform simplified check testing operations for tumble dryers Version 6.0 April 2015 Table of
More informationOPTIONAL INFORMATION PORTABLE FIRE EXTINGUISHERS SELF INSPECTION CHECKLIST
OPTIONAL INFORMATION Name of School: Date of Inspection: Vocational Program/Course/Room: Signature of Inspector: PORTABLE FIRE EXTINGUISHERS Guidelines: This checklist covers the "Uniform Fire Code" regulations
More informationDRY POWDER FIRE EXTINGUISHER (Stored Pressure) ABC TYPE - PORTABLE
DRY POWDER FIRE EXTINGUISHER (Stored Pressure) ABC TYPE - PORTABLE Capacity: 1,, 5, 10 Kgs UFS dry powder type extinguishers are designed for protection of light and ordinary hazards. Suitable for A, B,
More informationORDINANCE FOR TECHNICAL SPECIFICATIONS PERTAINING TO AEROSOL TYPE EXTINGUISHER APPLIANCES
This translation is provisional translation for reference, formally refer to the original text. ORDINANCE FOR TECHNICAL SPECIFICATIONS PERTAINING TO AEROSOL TYPE EXTINGUISHER APPLIANCES (Ordinance of the
More informationISO INTERNATIONAL STANDARD. Fire-fighting hoses Rubber and plastics suction hoses and hose assemblies
INTERNATIONAL STANDARD ISO 14557 First edition 2002-12-01 Fire-fighting hoses Rubber and plastics suction hoses and hose assemblies Tuyaux de lutte contre l incendie Tuyaux d aspiration et flexibles en
More informationARKANSAS FIRE PROTECTION LICENSING BOARD RULES AND GEGULATIONS FOR PORTABLE/FIXED SYSTEMS EFFECTIVE: JULY 1, 2013
ARKANSAS FIRE PROTECTION LICENSING BOARD RULES AND GEGULATIONS FOR PORTABLE/FIXED SYSTEMS EFFECTIVE: JULY 1, 2013 SECTION 1. SCOPE, PURPOSE AND FAIRNESS 1. PURPOSE. The purpose of the Rules and Regulations
More informationPURPLE K POWDER EXTINGUISHERS INSTALLATION, OPERATION, MAINTENANCE AND RECHARGE MANUAL
PURPLE K POWDER EXTINGUISHERS INSTALLATION, OPERATION, MAINTENANCE AND RECHARGE MANUAL NO. 05602 FOR AMEREX STORED PRESSURE, HAND PORTABLE DRY CHEMICAL FIRE EXTINGUISHERS. ABC (Ammonium Phosphate Base)
More informationTender document for Supply/ Installation of New Fire extinguishers & Refilling TENDER NOTICE
Relationship beyond banking Zonal Office, Bhopal Zone Bank of India Bhawan Jail Road, Arera Hills BHOPAL - 462011, MP. Phone. 0755-2764698 zo.bhopal@bankofindia.co.in ZOBDSDSGNFE TENDER2013-14 Dated 05.11.2013
More informationSubchapter 7. General Industry Safety Orders Group 27. Fire Protection Article 157. Portable Fire Extinguishers. Return to index New query
This information is provided free of charge by the Department of Industrial Relations from its web site at www.dir.ca.gov. These regulations are for the convenience of the user and no representation or
More informationREGISTRY OF RADIOACTIVE SEALED SOURCES AND DEVICES SAFETY EVALUATION OF DEVICE (Amends In Its Entirety)
NO. : NC-646-D-128-S DATE: February 23, 2012 PAGE: Page 1 of 8 MODEL No.: 3241-C, 3241-D & 3241-G MANUFACTURER/DISTRIBUTOR: Troxler Electronic Laboratories, Inc. P.O. Box 12057 3008 Cornwallis Road Research
More informationMOBILE FOOD SERVICE EQUIPMENT FIELD APPROVAL SUBMISSION INFORMATION
Page: 1 of 5 The following will outline the information and material required to process the Field Approval of Mobile Food Service Equipment (MFSE). 1. Type of MFSE. See Page 2. 2. Equipment Identification
More informationGASTEC QA. Approval Requirements 31-1
KE 31-1 March 2012 GASTEC QA Approval Requirements 31-1 for the GASTEC QA product certificate for Sealing materials for metallic threaded joints in contact with 2nd and 3rd family gases and hot water Part
More information5.07 Air Replenishment Systems
5.07 Air Replenishment Systems Reference: 2010 SFFC, Section 511.2 Definitions: CERTIFIED COMPRESSOR. A compressor used by a contractor for maintenance and testing of air replenishment systems that is
More informationAMENDMENT NO. 1 TO IS 2878:2004 FIRE EXTINGUISHER, CARBON DIOXIDE TYPE (PORTABLE AND TROLLEY MOUNTED) - SPECIFICATION
Doc: CED 22(7273) AMENDMENT NO. 1 TO IS 2878:2004 FIRE EXTINGUISHER, CARBON DIOXIDE TYPE (PORTABLE AND TROLLEY MOUNTED) - SPECIFICATION (Foreword) Insert the following new clause: `A scheme for labeling
More informationSECTION WET-PIPE SPRINKLER SYSTEMS
SECTION 21 13 13 WET-PIPE SPRINKLER SYSTEMS PART 1 - GENERAL 1.1 SCOPE OF WORK A. Design, installation and testing shall be in accordance with NFPA 13 except for specified exceptions. B. The demolition
More informationA.C.A. Tit. 20, Subtit. 2, Ch. 22, Subch. 6 Note
A.C.A. Tit. 20, Subtit. 2, Ch. 22, Subch. 6 Note Arkansas Code of 1987 Annotated Official Edition 1987-2014 by the State of Arkansas All rights reserved. *** Legislation is current through the 2013 Regular
More informationRULES OF DEPARTMENT OF COMMERCE AND INSURANCE DIVISION OF FIRE PREVENTION CHAPTER FIRE PROTECTION SPRINKLER SYSTEM CONTRACTORS
RULES OF DEPARTMENT OF COMMERCE AND INSURANCE DIVISION OF FIRE PREVENTION CHAPTER 0780-02-07 FIRE PROTECTION SPRINKLER SYSTEM CONTRACTORS TABLE OF CONTENTS 0780-02-07-.01 Definitions 0780-02-07-.08 Installation,
More informationSERVICE MANUAL (v1) UL / ULC. WET CHEMICAL HAND PORTABLE RESTAURANT KITCHEN FIRE EXTINGUISHERS Model: SF-6LK / WBDL-6LK
STRIKE FIRST CORPORATION AKC SERVICE MANUAL (v1) UL / ULC WET CHEMICAL HAND PORTABLE RESTAURANT KITCHEN FIRE EXTINGUISHERS Model: SF-6LK / WBDL-6LK All fire extinguishers should be installed, inspected
More informationF-CLASS MODEL M6L WET CHEMICAL FIRE EXTINGUISHER Installation, Operation, Recharge and Maintenance Manual
F-CLASS MODEL M6L WET CHEMICAL FIRE EXTINGUISHER Installation, Operation, Recharge and Maintenance Manual 008094 All fire extinguishers should be installed, inspected and maintained in accordance with
More informationCat 5 Pro Vacuum OPERATOR S MANUAL
Cat 5 Pro Vacuum OPERATOR S MANUAL Concrete Polishing Solutions PO Box 520 * Norris, TN 37828 Phone: (865) 494-8200 * Fax: (865) 494-8300 Toll Free: (877) 472-8200 * www.go2cps.com Table Of Contents General
More informationRisk Management Resources
Risk Management Resources Portable Fire Extinguishers Self-Inspection Checklist Guidelines: This checklist covers regulations issued by the U.S. Department of Labor, Occupational Safety and Health Administration
More informationAS Australian Standard. Portable fire extinguishers Guide to servicing. This is a free 7 page sample. Access the full version online.
AS 3676 1989 Australian Standard Portable fire extinguishers Guide to servicing This Australian Standard was prepared by Committee FP/3, Fire Extinguishers. It was approved on behalf of the Council of
More informationISO 6183 INTERNATIONAL STANDARD. Fire protection equipment Carbon dioxide extinguishing systems for use on premises Design and installation
INTERNATIONAL STANDARD ISO 6183 Second edition 2009-06-15 Fire protection equipment Carbon dioxide extinguishing systems for use on premises Design and installation Équipement de protection contre l'incendie
More informationInformation Bulletin
Date of manufacture stamping of portable fire extinguisher cylinders Version 1.1 Approved for release July 2014 1.0 Purpose Statement The purpose of this document is to provide information on the date
More informationSUBSIDIARY LEGISLATION STEAM AND HOT WATER BOILERS REGULATIONS
STEAM AND HOT WATER BOILERS [S.L.424.07 1 SUBSIDIARY LEGISLATION 424.07 STEAM AND HOT WATER BOILERS REGULATIONS 19th April, 1976 LEGAL NOTICE 34 of 1976, as amended by Act XXVII of 2000 and Legal Notice
More informationOWNER'S SERVICE MANUAL NO INSPECTION, MAINTENANCE AND RECHARGE
FOAM FIRE EXTINGUISHERS MODEL 254-6 LITER AFFF FOAM WITH SPRAY NOZZLE Model 250 2 ½ GAL.LON AFFF FOAM WITH ASPIRATED NOZZLE MODEL 252 2 ½ GAL.LON FFFP (ALCOHOL RESISTANT) FOAM WITH ASPIRATED NOZZLE OWNER'S
More informationGASTEC QA. Approval Requirements 31-2
KE 31-2 March 2012 GASTEC QA Approval Requirements 31-2 for the GASTEC QA product certificate for Sealing materials for metallic threaded joints in contact with 2nd and 3rd family gases and hot water Part
More informationFIRE EXTINGUSIHER INSPECTION, MAINTENANCE, AND TESTING PROCEDURES
FIRE EXTINGUSIHER INSPECTION, MAINTENANCE, AND TESTING PROCEDURES FLS has organized the following information to act as a guideline/checklist for any inspection, maintenance, recharging and testing that
More informationCoatings for protection of FRP structures with heavy rain erosion loads
CLASS PROGRAMME Type approval DNVGL-CP-0424 Edition May 2016 Coatings for protection of FRP structures with heavy rain erosion loads The content of this service document is the subject of intellectual
More informationIQ/OQ Protocol Installation Qualification/ Operation Qualification
IQ/OQ Protocol Installation Qualification/ Operation Qualification FlaskScrubber Vantage TM Series Glassware Washer Labconco o: 1058701 Rev. B Available at www.labconco.com or by e-mail in Word 2000 document
More informationCapital Projects Group Fire Extinguishers Specification
Capital Projects Group Fire Extinguishers Specification Specification 21 20 05 Revision 0 Date: August 2018 Fire Extinguishers Specification Specification 21 20 05 Publication Date: August 2018 COPYRIGHT
More informationMAINTENANCE AND INPSECTION OF FIRE PROTECTION SYSTEMS AND APPLIANCES
SHIPPING NOTICE Maritime Authority of the Cayman Islands Head Office 3 rd Floor, Government Administration Building, 133 Elgin Avenue PO Box 2256, Grand Cayman, KY1-1107, Cayman Islands Tel: +1 345 949
More informationAustralian/New Zealand Standard
AS/NZS 1841.1:2007 AS/NZS 1841.1:2007 Australian/New Zealand Standard Portable fire extinguishers Part 1: General requirements AS/NZS 1841.1:2007 This Joint Australian/New Zealand Standard was prepared
More informationPublic Notice of Amendment to New Shoreham General Ordinances Chapter 5 Fire Prevention and Protection New Article IV Fire Alarm Ordinance
Public Notice of Amendment to New Shoreham General Ordinances Chapter 5 Fire Prevention and Protection New Article IV Fire Alarm Ordinance It is ordained by the Town Council of the Town of New Shoreham
More informationNUCLEAR POWER CORPORATION OF INDIA LIMITED (A Government of India Enterprise)
(A Government of India Enterprise) 2 X 1000 MWe KUDANKULAM NUCLEAR POWER PROJECT UNITS-1&2 TECHNICAL SPECIFICATI FOR PORTABLE FIRE EXTINGHISHERS Number of the Document I02 KK12 0 SGA TH TS P01 Title Total
More informationIranian Classification Society Convention and Legislation Department Code: Tech Contents
Page 2 of 12 Contents section A)Fire fighting appliances(ffa): 3 section B)Life saving appliances(lsa)... 9 section C)Attachements... 12 SECTION A) 1. General guide for Firefighting appliances(ffa): 1.1
More informationWinnipeg Fire Department Fire Prevention Branch
Winnipeg Fire Department Fire Prevention Branch Manitoba Fire Code Life-Safety Equipment Maintenance Requirements The Fire Prevention Branch of the Winnipeg Fire Department has prepared this document of
More informationDOSH-SIRIM PPE APPROVAL CERTIFICATION & TESTING. Presenter; Azmi Musa SIRIM QAS INTERNATIONAL SDN. BHD.
DOSH-SIRIM PPE APPROVAL CERTIFICATION & TESTING Presenter; Azmi Musa SIRIM QAS INTERNATIONAL SDN. BHD. PRESENTATION CONTENT About SIRIM QAS INTERNATIONAL Personal Protective Equipment (PPE) Standards for
More informationInstallation & Maintenance Instructions
IMPORTANT INSTRUCTIONS READ AND SAVE THESE INSTRUCTIONS Saving energy and creating healthy, comfortable environments No. II-450 Date July, 2015 DRIVE-THRU UNIT 3 AIR CURTAIN SERIES DTU03 for outdoor use
More informationLoss Prevention Standard
Loss Prevention Standard LPS 1500: Issue 2.1 provide compartmentation in buildings This standard defines the requirements for companies installing fire resisting compartment systems approved by LPCB to
More informationThe New EMC Directive 2004/108/EC
The New EMC Directive 2004/108/EC In the process of this review I have tried to spell out in words what is often referred to as a section number while also keeping to location information as used in the
More informationTHE FIRE SAFETY GUIDE FOR BUSINESS OWNERS
THE FIRE SAFETY GUIDE FOR BUSINESS OWNERS 0800 2211 8034 Table of Contents Part 1: Introduction Part 2: Who is Responsible? Part 3: What is Required? Fire Risk Assessments Appointment of Competent Persons
More informationTechnical Data Sheet No. JS-SM-38 DOCUMENT TITLE 3.5KG CARBON DIOXIDE FIRE EXTINGUISHERS
PAGE: ISSUE: DATE: of 2 A 00 07/22/5 DOCUMENT TITLE 3.5KG CARBON DIOXIDE FIRE EXTINGUISHERS MODELS: R3.5CO2 0 07/22/5 FIRST ISSUE A WJJ LRL LHG REV DATE REVISION DESCRIPTION BY CHK APP COVER PAGE/REVISION
More informationAenor Mark Specific Rules for polyethylene compounds (PE) for the manufacturing of pipes for gaseous fuels
Aenor Mark Specific Rules for polyethylene compounds (PE) for the manufacturing of pipes for gaseous fuels Note: This document is a translation of the Spanish document RP 01.37 rev 9 approved by the Plastics
More informationGUIDELINES FOR THE APPROVAL OF EQUIVALENT FIXED GAS FIRE-EXTINGUISHING SYSTEMS, AS REFERRED TO IN SOLAS 74, FOR MACHINERY SPACES AND CARGO PUMP-ROOMS
12 December 1996 Ref. T4/4.01 GUIDELINES FOR THE APPROVAL OF EQUIVALENT FIXED GAS FIRE-EXTINGUISHING SYSTEMS, AS REFERRED TO IN SOLAS 74, FOR MACHINERY SPACES AND CARGO PUMP-ROOMS 1 The Maritime Safety
More informationPRESTO DRY POWDER FIRE EXTINGUISHERS - AB:E
- 1 - PRESTO DRY POWDER EXTINGUISHERS - AB:E Certified & Approved to AS/NZS 1841.5 Deep drawn steel cylinder with welded base and robust skirt., giving extra resistance to standard corrosive environments
More informationKidde Nitrogen Inert Gas Clean Agent Fire Suppression System
1. GENERAL 1.1 INTENT OF SPECIFICATIONS A. This specification details the requirements for an engineered inert gas fire suppression system Model Kidde Nitrogen. These requirements, combined with good engineering
More informationTHE REPUBLIC OF UGANDA ATOMIC ENERGY ACT, 2008 SCHEDULE 1 FORM 2A
ATOMIC ENERGY COUNCIL P.O.BOX 7044 KAMPALA Regulation 15 ATOMIC ENERGY FORM 2A (AEF 2A) THE REPUBLIC OF UGANDA ATOMIC ENERGY ACT, 2008 SCHEDULE 1 FORM 2A APPLICATION FOR AUTHORIZATION TO POSSESS AND USE
More informationAMENDMENTS TO THE BUILDING AND FIRE CODE FOR THE CITY AND COUNTY OF DENVER
AMENDMENTS TO THE BUILDING AND FIRE CODE FOR THE CITY AND COUNTY OF DENVER The 2016 Denver Building and Fire Code includes the following codes except as amendment herein. 2015 IBC (Building) 2015 IFC (Fire)
More informationANN ARBOR CITY NOTICE ORDINANCE NO. ORD ALARM SYSTEMS
ANN ARBOR CITY NOTICE ORDINANCE NO. ORD-16-14 ALARM SYSTEMS AN ORDINANCE TO AMEND SECTIONS 7:402, 7:405, 7:406, AND 7:407 OF CHAPTER 93, ALARM SYSTEMS, OF TITLE VII OF THE CODE OF THE CITY OF ANN ARBOR
More informationOWNER S MANUAL WARRANTY INFORMATION AND INSTALLATION INSTRUCTIONS PROFLO AND MARATHON ELECTRIC STORAGE WATER HEATERS
OWNER S MANUAL WARRANTY INFORMATION AND INSTALLATION INSTRUCTIONS PROFLO AND MARATHON ELECTRIC STORAGE WATER HEATERS MODELS: 25V1, 25P1, 50V1, 50P1, 50H1, 80F1, 80H1, 125F1, 125F2, 125H1, 160F1, 160F2,
More informationGASTEC QA. Approval Requirements 136
KE 136 January 2012 GASTEC QA Approval Requirements 136 for the GASTEC QA product certificate for Polyethylene (PE) valves for plastic piping systems for the supply of gaseous fuels Foreword These GASTEC
More informationISO/TS TECHNICAL SPECIFICATION. Fire protection Portable and wheeled fire extinguishers Part 2: Inspection and maintenance
TECHNICAL SPECIFICATION ISO/TS 11602-2 First edition 2010-08-15 Fire protection Portable and wheeled fire extinguishers Part 2: Inspection and maintenance Protection contre l'incendie Extincteurs portatifs
More informationOUT CARBON DIOXIDE (CO2) EXTINGUISHER Certified & Approved to AS/NZS Lightweight Aluminium Cylinder. AS High pressure hose assembly with
OUT DRY POWDER EXTINGUISHERS - AB:E Certified & Approved to AS/NZS 1841.5 Deep drawn steel cylinder with welded base and robust skirt., giving extra resistance to standard corrosive environments together
More informationIMO INTERPRETATIONS OF FIRE PROTECTION-RELATED PROVISIONS OF THE HSC CODE
INTERNATIONAL MARITIME ORGANIZATION 4 ALBERT EMBANKMENT LONDON SE1 7SR Telephone: 0171-735 7611 Fax: 0171-587 3210 Telex: 23588 IMOLDN G Ref. T4/4.01 IMO E MSC/Circ.911 4 June 1999 INTERPRETATIONS OF FIRE
More informationCouncil Directive 93/68/EEC of 22 July 1993 amending Directives
Council Directive 93/68/EEC of 22 July 1993 amending Directives 87/404/EEC (simple pressure vessels), 88/378/EEC (safety of toys), 89/106/EEC (construction products), 89/336/EEC (electromagnetic compatibility),
More informationGK/GN0612. Guidance on Signalling Lockout Systems to Protect Railway. Undertaking Personnel. Railway Group Guidance for GK/RT0212.
GN Published by Rail Safety and Standards Board Evergreen House 160 Euston Road London NW1 2DX Copyright 2007 Rail Safety and Standards Board Limited GK/GN0612 Issue One: August 2007 Railway Group Guidance
More informationCode of Practice Version 2 Metal Detection and X-Ray Systems
Code of Practice Version 2 Metal Detection and X-Ray Systems Contents Page No. 1. Introduction & Objective 3 2. Risk Assessment & General Requirements 4 3. Location 5 4. Sensitivity 6 5. Detection Operation
More informationHydrostatic Retest Requirements for ANSUL Pressure Vessels
TECHNICAL BULLETIN Hydrostatic Retest Requirements for ANSUL Pressure Vessels Portables, Wheeled Units, and Pre-engineered Pressure Vessels One Stanton Street Marinette, WI 54143-2542, USA +1-715-735-7411
More informationISO INTERNATIONAL STANDARD. Fire protection Automatic sprinkler system Part 9: Requirements and test methods for water mist nozzles
INTERNATIONAL STANDARD ISO 6182-9 First edition 2005-11-01 Fire protection Automatic sprinkler system Part 9: Requirements and test methods for water mist nozzles Protection contre l'incendie Systèmes
More informationHigh Plume Blowers Suggested Specification Section (Master Format 1996) Suggested Specification Section (Master Format 2004)
High Plume Blowers Suggested Specification Section 15500 (Master Format 1996) Suggested Specification Section 23 38 16 (Master Format 2004) PART 1 GENERAL 1.01 WORK INCLUDED High Plume Laboratory Exhaust
More informationFIREWORLD DRY POWDER ABE FIRE EXTINGUISHERS
- 1 - WORLD DRY POWDER ABE EXTINGUISHERS Certified & Approved to AS/NZS 1841.5 Fireworld Deep drawn steel cylinder with welded base and robust skirt., giving extra resistance to standard corrosive environments
More informationReflex fire detection and extinguishing system filled with ABC dry powder. Installation, operation and maintenance instructions
Reflex fire detection and extinguishing system filled with ABC dry powder Installation, operation and maintenance instructions document number: 0221.321 revision: A:01.09.2018 table of contents 1. Your
More informationStandard ECMA th Edition - December Declared Noise Emission Values of Information Technology and Telecommunications Equipment
Standard ECMA-109 4 th Edition - December 1996 Standardizing Information and Communication Systems Declared Noise Emission Values of Information Technology and Telecommunications Equipment Phone: +41 22
More informationISO INTERNATIONAL STANDARD. Coating powders Part 13: Particle size analysis by laser diffraction
INTERNATIONAL STANDARD ISO 8130-13 First edition 2001-09-01 Coating powders Part 13: Particle size analysis by laser diffraction Poudres pour revêtement Partie 13: Analyse granulométrique par diffraction
More informationTHÔNG BÁO KỸ THUẬT TÀU BIỂN TECHNICAL INFORMATION ON SEA-GOING SHIPS
VRTB.TI CỤC ĐĂNG KIỂM VIỆT NAM VIETNAM REGISTER ĐỊA CHỈ: 18 PHẠM HÙNG, HÀ NỘI ADDRESS: 18 PHAM HUNG ROAD, HA NOI ĐIỆN THOẠI/ TEL: +84 4 3 7684701 FAX: +84 4 3 7684779 EMAIL: vr-id@vr.org.vn WEB SITE: www.vr.org.vn
More informationJune 2018 Safety Meeting Fire Extinguishers Part I
June 2018 Safety Meeting Fire Extinguishers Part I The portable fire extinguisher, one of the most common fire protection appliances in use today, is found in fixed facilities and on propane vehicles.
More informationBlack Diamond Fire Department Building Owner s Responsibilities for Fire Safety Equipment
Black Diamond Fire Department Building Owner s Responsibilities for Fire Safety Equipment February 2017 Alberta Fire Code safety equipment maintenance requirements: The Black Diamond Fire Department has
More information