DB4 Range - SPEAKERS - Up to 25 Watts

Size: px
Start display at page:

Download "DB4 Range - SPEAKERS - Up to 25 Watts"

Transcription

1 DB Range - SPEAKERS - Up to 5 Watts Hazardous Location, Weatherproof Features UL listed for USA and Canada Class I, Div, Groups A, B, C & D. Class I, Zone, AExd IIC T. CSFM approved. ATEX approved. NEMA x and 6, IP66 & 67. Certified temperature: 67 F to +58 F. 55 C to + C. GRP corrosion-free flamepaths. 9dBA at 5 watts at feet. 8, 5 and 5 watt versions. Power tappings, via integral transformer. Ratcheted swivel bracket. Stainless steel sinter. Stainless steel mounting bracket. Tapered flamepath. V line and 8Ω versions available. Introduction This range of loudspeakers, intended for use in potentially explosive atmospheres, has a power rating of up to 5 watts and is suitable for use in all gas groups including hydrogen. The flamepaths, flare and the body are manufactured completely from a UV stable glass reinforced polyester. 6 Stainless steel screws and sinter are incorporated thus ensuring a corrosion free product. A tapered flamepath is used to overcome the problems of assembly of parallel spigot flamepaths. European, Russian and other worldwide approvals are available, refer to main section of catalog. Cooper MEDC Limited, Colliery Road, Pinxton, Nottingham NG6 6JF, UK. Cooper MEDC (USA) North Sam Houston Parkway West Suite Houston, TX 786, USA Sales Enq. UK: + ()77 86 Sales Enq. USA: + (7) medc.sales@cooperindustries.com Web: medc.com 6DSUS7/I

2 Specification Certification: UL Listed for USA and Canada Class I, Div, Groups A-D. Class I, Zone, AExd IIC T. UL Listing No. E. Zones and. Not for use in atmospheres containing carbon disulphide. Material: Body & horn in antistatic, UV stable, glass reinforced plastic. Swivel bracket in stainless steel. Captive cover screws in stainless steel. Finish: Body & horn, natural black or painted to customer's specification. Rated Power: 8, 5 or 5 watts RMS continuous (at 77 F). Certified Temp: 67 F to +58 F. 55 C to + C. Weight: lb/5.kg approx. dependent on model. Ingress Protection: NEMA x and 6, IP66 & 67. Entries: Up to x /" NPT. Terminals: 8 x AWG Other terminal arrangements available on request. Output: 97 dba at watt at feet. 9 dba at 5 watts at feet. Measured in accordance with IEC 68. Frequency Range: Hz to 8kHz. Voice Coil Impedence: 8 ohms. Mounting: Bracket with ratchet facility. Labels: Duty and tag labels optional. ALL DIMENSIONS IN INCHES (Exe).5 (Exd).5 (Exd) 7-9/" -/6±/8" 5-5 WATT VERSION -/6±/8" WITHOUT Exe CHAMBER 9-/"±/8" 8 WATT VERSION 7-/"±/8" WITHOUT Exe CHAMBER FIXING HOLES -7/6" Ø/6" ( POS.) xm ENTRIES (Exe UNIT) FIXING HOLE Ø/6" -/6" CRS Ø-5/8" -/6" CRS Ø5-/6" 8 WATT VERSION OPTIONAL Exe CHAMBER Ø6-/6" 5&5 WATT VERSION FOR Exd UNIT, POSITION IS USED xm ENTRIES MAX IF ONLY x M ENTRY REQUIRED (Exd UNIT) Frequency W/' for 5W Unit : Tapping Options: 5 6 Used to vary the rated power by selecting different tappings (see table below). i) Loop in/loop out ( x ) power tap change; 8 terminals. ii) terminal tap change with terminals (5 & 6) directly connected to driver (8 ohms). Ordering Requirements Power Tappings 5W 5W 8W : : : :...5 :...7 :..8. The following code is designed to help in selection of the correct unit. Build up the reference number by inserting the code for each component into the appropriate box. SPL (db) Frequency, Hz DB khz Model DB Max Rated P ower Certification UL Tag/Duty Entries Finish Power Code 8 watt 8 5 watt 5 5 watt 5 To order ATEX approved version, see European data sheet. Code Yes X* No N * Std V. Other voltages available, specify voltage. Label Code Duty D* Tag T* None N * Please specify wording Entries Code x /"NPT C x /"NPT C To specify certified plug, suffix appropriate code with P. e.g. CP is x /" NPT entries with one certified plug. Color Code Natural Black N Red R Special S* * Please specify All the above specifications, dimensions, weights and tolerances are nominal (typical) and Cooper MEDC reserve the right to vary all data without prior notice. No liability is accepted for any consequence of use. /

3 DB Range - SPEAKERS - Up to 5 Watts Exde, Weatherproof Features Zone, Zone & non-ex use. Exde IIB + H or IIC T/T5/T6 ATEX certified, Ex II G IECEx certified, Gb Certified by BASEEFA GOST 'R' & 'K' certified.* Chinese (CQST) certified.* Brazilian (Inmetro) certified.* IP66 and IP67 Certified temperature: - C to +65 C.** GRP corrosion-free flamepath. 5dB(A) at 5 Watts at metre. 8 & 5 Watt versions. Power tappings via integral transformer. Ratcheted swivel mounting stirrup. Fitted with 6L stainless steel fixtures. Earth continuity available. Retained cover screws. Introduction This range of loudspeakers, intended for use in potentially explosive gas atmospheres, has a power rating of up to 5 Watts and is suitable for use in gas groups IIB plus hydrogen and IIC. Internal earth stud fitted as standard. *Please contact Cooper MEDC Technical Sales. ** Model dependant, please contact Cooper MEDC Technical Sales for - C products. The flamepaths, flare and body, are manufactured from a UV stable glass reinforced polyester. Stainless steel screws and mounting stirrup are incorporated to ensure a corrosion-free product. Cooper MEDC Limited, Colliery Road, Pinxton, Nottingham NG6 6JF, UK. Cooper MEDC (USA) North Sam Houston Parkway West Suite Houston, TX 786, USA Sales Enq. UK: + ()77 86 Sales Enq. USA: + (7) medc.sales@cooperindustries.com Web: medc.com 6DS/I

4 Specification Certification: Standards: IEC/EN 79-, 79-, IECEx IIB + H Cert details: IECEx BAS.X IECEx IIC Cert details: IECEx BAS.X Ex de IIB + H T, T5 or T6 Gb. Ex de IIC T, T5 or T6 Gb. ATEX IIB + H Cert details: BaseefaATEXX ATEX IIC Cert details: BaseefaATEXX Ex II G Ex de IIB+H T/T5/T6 Gb Ex II G Ex de IIC T/T5/T6 Gb GOST 'R' Certification: Exde IIB + H T/T5/T6.* GOST 'K' Certification: Exde IIB + H T/T5/T6.* Chinese (CQST) Certification: Exde IIB + H T/T5/T6.* Brazilian (Inmetro) Certification: BR-Ex de IIB + H T/T/T5/T6.* Material: Body & horn in anti-static, UV stable, glass reinforced polyester. Mounting stirrup and fixtures in 6L stainless steel. Finish: All natural or body and horn can be painted to customer specification. Rated Power: 8 & 5 Watts RMS continuous (5ºC). Weight: Long Flare (5W):.5kg Gross weight..6kg Net weight Short Flare (8W): kg Gross weight..kg Net weight Ingress Protection: IP66 and IP67 Entries: Up to x M ISO into Exe chamber. Terminals: 8 x.mm² or x.mm². Output: Maximum output for IIB W/M is 5dB(A) Maximum output for IIB 5W/M is 5dB(A) Maximum output for IIC W/M is 98dB(A) Maximum output for IIC 5W/M is 7dB(A) Frequency Range: Hz to 8kHz. Certified Temp: - C to + C (T6)** - C to + 55 C (T5)** - C to + 65 C (T)** Voice Coil Impedence: 8 ohms. Fire Retardancy: GRP is fire retardant to ISO. Mounting: Via stirrup with ratchet facility (supplied fitted). Earth Continuity: Internal/External earth stud linked to gland continuity. Labels: Optional stainless steel tag and duty labels. : V line as standard. Use by combining the rated power tappings below. Terminals Power 5W 8W : (HI) 5.W 8.W : (HI) 7.5W.W : (HI).75W.W : (LO).5W.W : (LO).5W.5W : (LO).75W.5W Ordering Requirements Tapping Options: Standard: i) 8 terminals ( x ), loop in/loop out for 6 tappings. Optional: ii) terminals ( x ), loop in/loop out, direct 8Ω conection to driver. SPL (db) Frequency W/M for IIB+H Long Flare version (/ Octave Pink Noise) rd Octave Frequency, Hz DB IIB+H khz The following code is designed to help in selection of the correct unit. Build up the reference number by inserting the code for each component into the appropriate box. Standard products available ex-stock. Please visit the Cooper MEDC website for further details. Model DB Certification Gas Group Max Rated Power Options Entries Finish Certification Code ATEX B IECEx J GOST R R* GOST K K* Chinese (CQST) Q* Inmetro EM* Group IIB+H IIC Code B C Power Code 8 Watt 8 5 Watt 5 * Please contact Cooper MEDC Technical Sales for availability. ** Model dependant, please contact Cooper MEDC Technical Sales for -ºC products. Code Yes X* 8 ohm version N * Std V Other values available, specify voltage. Options Code Duty D* Tag T* Earth Continuity ES including stud Ext. Earth Stud S (only) None N Entries Code x M B x M B x M entries BP with one certified plug fitted Finish Code Natural Black N Red R Special S* * Please specify. * Please specify wording All the above specifications, dimensions, weights and tolerances are nominal (typical) and Cooper MEDC reserve the right to vary all data without prior notice. No liability is accepted for any consequence of use. /

5 DB Range - SPEAKERS - Up to 5 Watts Harsh Industrial & Marine Environments Features IP66 and IP67. Temperature range: 55 C to + C. Corrosion resistant GRP. 7dBA at 5 watts at metre. V line transformer. Power tappings, via integral transformer. Addressable capability. Stainless steel ratcheted mounting bracket. Earth continuity available. BS589 part 8 compliant version available. Introduction This range of loudspeakers has a power rating of 5 Watts and is suitable for use in demanding environments where a robust construction and high ingress protection rating is required. The body is manufactured completely from a UV stable glass reinforced polyester which is also highly flame retardant and impact resistant. Stainless steel screws are incorporated thus ensuring a corrosion free product. MEDC can also provide a range of speakers suitable for use in potentially explosive atmospheres. For more information please contact Cooper MEDC. Cooper MEDC Limited, Colliery Road, Pinxton, Nottingham NG6 6JF, UK. Cooper MEDC (USA) North Sam Houston Parkway West Suite Houston, TX 786, USA Sales Enq. UK: + ()77 86 Sales Enq. USA: + (7) medc.sales@cooperindustries.com Web: medc.com 6DS6/F

6 Specification Material: Body & horn in UV stable, glass reinforced polyester. Swivel bracket in stainless steel. Cover screws in stainless steel. Finish: Painted to customer's specification. Rated Power: 5 watts RMS continuous (at 5 C). Certified Temp: 55 C to + C. Weight:.6kg approx. dependent on model. Ingress Protection: IP66 & IP67. Entries: x M ISO. Terminals: Up to 8 x.5mm. Other terminal arrangements available on request. Output: Maximum output at W/m at Hz is 7 dba. Maximum output at 5W/m at Hz is 7 dba. Frequency Range: Hz to 7kHz. Voice Coil Impedence: 8 ohms. Mounting: Via stirrup with ratchet facility. Earth Continuity: Available. Labels: Duty and tag labels optional. : Used to vary the rated power by selecting different tappings (see table below). Ø6± MOUNTING HOLE ر MOUNTING HOLES Ø7± OFF POS. 5± MOUNTING STIRRUP ر ± ± ± ALL DIMENSIONS IN MILLIMETRES ± ± Frequency W/M for 5W Unit (/ Octave Pink Noise) 5 6 8Ω Options: Standard: i) Standard Tapping: Loop in/loop out ( x ) terminal tap change (8 terminals). ii) Optional Tapping: terminal tap change with terminals (5 & 6), directly connected to driver (8 ohms). Ordering Requirements Power Tappings W : 5. : 7.5 : 5. :. :. :.8 The following code is designed to help in selection of the correct unit. Build up the reference number by inserting the code for each component into the appropriate box. Standard products available ex-stock. Please visit for further details. SPL (db) Frequency, Hz DB khz Model DB Option Finish Code Yes X* None N * Standard V Other voltages available, specify voltage. Option Code Duty label D* Tag label T* Earth continuity E BS589, part 8 PT8 compliant Blanking Plug P None N Finish Code Painted Grey G Red R Special S* *Please specify * Please specify wording All the above specifications, dimensions, weights and tolerances are nominal (typical) and Cooper MEDC reserve the right to vary all data without prior notice. No liability is accepted for any consequence of use. /

7 DB6 Range - SPEAKERS - Up to Watts Hazardous Locations, Weatherproof Features UL listed for USA and Canada Hazardous locations: Class I, Div, Groups A-D* Class I, Zone, AExde IIB/IIC T/T* Ordinary locations: Signalling Speaker. ATEX approved. NEMA x & 6, IP66 and IP67. Certified temperature: 67 F to + F. C to + C. GRP corrosion-free flamepath. Up to dba at Watts at feet*. Power tappings via integral transformer. Ratcheted swivel mounting stirrup. Stainless steel fixtures. V line or 8Ω versions available. (other voltages available on request) *Model dependent. Introduction This range of loudspeakers, intended for use in potentially explosive gas and dust atmospheres, has a power rating of up to Watts and is suitable for use in the harsh environmental conditions found offshore and onshore in the oil, gas and petrochemical industries. The flamepaths, flare and body, are manufactured from a UV stable glass reinforced polyester. Stainless steel screws and mounting stirrup are incorporated to ensure a corrosion-free product. European and other world wide approvals are available, refer to main section of catalog. Cooper MEDC Limited, Colliery Road, Pinxton, Nottingham NG6 6JF, UK. Cooper MEDC (USA) North Sam Houston Parkway West Suite Houston, TX 786, USA Sales Enq. UK: + ()77 86 Sales Enq. USA: + (7) medc.sales@cooperindustries.com Web: medc.com 6DSUS9/D

8 Specification Certification: UL Listed for USA and Canada Hazardous locations: Class I, Div, Groups C & D, Class I, Zone, AExde IIB T Class I, Div, Groups A-D, Class I, Zone, AExde IIC T C UL Listing No. E Ordinary locations: Signalling Speaker. UL Listing No CENELEC EN, 8, 9. Material: Body & horn in anti-static, UV stable, glass reinforced polyester. Mounting stirrup and fixtures in stainless steel. Finish: All natural or body and horn can be painted to client requirements. Rated Power: Watts RMS continuous (at 77 F/5 C). Certified Temp: -67 F to + F (- C to + C). Weight: lb/5.5kg approx. Ingress Protection: NEMA x & 6,IP66 & IP67. Entries: Up to x M with /" NPT adaptors or x M5 with /" NPT adaptors into termination (EExe) chamber. Terminals: 8 x.5mm. Output: Groups C & D Version: Maximum output at W at feet is dba Maximum output at W at feet is dba Groups A-D Version: Maximum output at W at feet is 97dBA Maximum output at W at feet is 9dBA Frequency Range: Hz to 8kHz. Voice Coil Impedence: 8Ω. Mounting: Via stirrup with ratchet facility. Earth Continuity: Available via optional earthing stud or by internal earth plate. Labels: Optional stainless steel tag and duty labels. : Used by combining the rated power tappings below. Tapping Options: i) Loop in/loop out ( x ) power tap change; 8 terminals. Tappings Power W : : 5 : : 6 : : 8Ω ii) Loop in/loop out ( x ) 8Ω; terminals. Ordering Requirements SPL (db) Frequency W/' for W Unit (/ Octave Pink Noise) - Groups C&D Version ALL DIMENSIONS IN INCHES Frequency, Hz DB6 khz The following code is designed to help in selection of the correct unit. Build up the reference number by inserting the code for each component into the appropriate box. Model DB6 Certification Options Entries Finish Certification Code UL (C & D) UB* UL (A-D) UC UL (ordinary locations) UW Unit suitable for gas groups. * C & D A-D To order ATEX approved version, see European data sheet. Code Yes X* No N * Standard V Other voltages available, specify voltage. Options Code None N Duty label D* Tag label T* Internal earth E continuity Earth stud B * Please specify Entries Code x /" NPT M x /" NPT M x /" NPT N x /" NPT N To specify certified plug, suffix appropriate code with P. Finish Code Natural Black N Red R Special S* * Please specify All the above specifications, dimensions, weights and tolerances are nominal (typical) and Cooper MEDC reserve the right to vary all data without prior notice. No liability is accepted for any consequence of use. /

9 DB8 - SPEAKERS - Up to 5 Watts Ex na, Weatherproof Features Zone use. Ex na II T. ATEX compliant, Ex II GD. BASEEFA tested. IP66 & 67. Ambient temperature: 55 C to +55 C. 7dbA at 5 Watts at metre. Power tappings via integral transformer. Stainless steel ratcheted swivel mounting stirrup. Stainless steel fixtures. V line or 8Ω. Introduction This loudspeaker, intended for use in Zone, potentially explosive gas and dust atmospheres, has a power rating of up to 5 Watts and is suitable for use in all gas groups including hydrogen. The flare and body are manufactured from a UV stable glass reinforced polyester. Stainless steel screws and mounting stirrup are incorporated to ensure a corrosion-free product. Cooper MEDC Limited, Colliery Road, Pinxton, Nottingham NG6 6JF, UK. Cooper MEDC (USA) North Sam Houston Parkway West Suite Houston, TX 786, USA Sales Enq. UK: + ()77 86 Sales Enq. USA: + (7) medc.sales@cooperindustries.com Web: medc.com 6DS5/D

10 Specification Certification: CENELEC EN,. Ex na II T 5 C (-55 C to +55 C) T, Zone. Material: Finish: Rated Power: Certified Temp: Weight: Ingress Protection: Entries: Body & horn in anti-static, UV stable, glass reinforced polyester. Mounting stirrup and fixtures in stainless steel. Natural Black or body and horn can be painted to client requirements. 5 watts RMS continuous (at 5 C). 55 C to +55 C..6kg approx. IP66 & IP67. x M ISO. Terminals: Up to 8 x.5mm. Output: Frequency Range: Maximum output at W/m at Hz is 7 dba. Maximum output at 5W/m at Hz is 7 dba. Hz to 7kHz. Voice Coil Impedence: 8 ohms. Fire Retardancy: GRP is fire retardant to ISO. Mounting: Earth Continuity: Labels: : Via stirrup with ratchet facility. Available. Optional stainless steel tag and duty labels. Used by combining the rated power tappings below. Ø6± MOUNTING HOLE ر MOUNTING HOLES Ø7± OFF POS. 5± MOUNTING STIRRUP ر ± ± ± ALL DIMENSIONS IN MILLIMETRES ± ± Frequency W/M for 5W Unit (/ Octave Pink Noise) 5 6 8Ω Tappings (Option (iii) shown) Options: Standard: i) Loop in/loop out ( x ) power tap change; 8 terminals. Optional: ii) Loop in/loop out ( x ) 8 ohm; terminals. iii) terminal tap change with terminals (5 & 6), directly connected to driver (8 ohms). Ordering Requirements Power Tappings W : 5. : 7.5 : 5. :. :. :.8 The following code is designed to help in selection of the correct unit. Build up the reference number by inserting the code for each component into the appropriate box. Standard products available ex-stock. Please visit for further details. SPL (db) Frequency, Hz DB8 khz Model DB8 Option Finish Code Yes X* and X8 8 ohm terminals None (direct to driver) N * Standard V Other voltagesavailable, specify voltage. Option Code Duty label D* Tag label T* Earth continuity E Blanking Plug P None N * Please specify wording Finish Code Natural Black N Red R Special S* *Please specify All the above specifications, dimensions, weights and tolerances are nominal (typical) and Cooper MEDC reserve the right to vary all data without prior notice. No liability is accepted for any consequence of use. /

11 DB Range - SPEAKERS - Up to 8 Watts Exde, Weatherproof Features Zone & (and Zone & : IIC version) plus non-ex use ATEX Approved II G Ex de IIB T/T* IIC Gas Group and Dust approved version available. BASEEFA certified. Brazilian (Inmetro) certified. GOST 'R' & 'K' certified. IECEx Approved. IP66 & IP67. Certified temperature: C to + C*. GRP corrosion-free flamepath. db(a) at 8 watts at metre (IIB Version) Power tappings via integral transformer. Ratcheted swivel mounting stirrup Stainless steel fixtures. V or V line and 8Ω versions available. Earth continuity available. Introduction *Temperature class relates to ambient temperature (see over) This range of loudspeakers, intended for use in potentially explosive atmospheres, has a power rating of up to 8 Watts and is suitable for use in the harsh environmental conditions found offshore and onshore in the oil, gas and petrochemical industries. The body and cover are manufactured from a UV stable glass reinforced polyester. The flare is manufactured from UV stable ABS. Stainless steel screws and mounting stirrup are incorporated to ensure a corrosion-free product. Cooper MEDC Limited, Colliery Road, Pinxton, Nottingham NG6 6JF, UK. Cooper MEDC (USA) North Sam Houston Parkway West Suite Houston, TX 786, USA Sales Enq. UK: + ()77 86 Sales Enq. USA: + (7) medc.sales@cooperindustries.com Web: medc.com 6DS5/I

12 Specification Certification: Power (Watts) Tappings 8W unit W Unit EN79-, EN79-, EN79-7 IEC79-, IEC79-, IEC79-7 and IEC 6-, IEC 6- IIB Version: : 8.. :.. :.. :..75 :.75.8 :.. ATEX Cert. No. Baseefa5ATEX98X Ex II G Ex de IIB T/T IECEx Cert. No. IECEx BAS 5.8X Ex de IIB T/T IIC Version: ATEX Cert. No. Baseefa5ATEX99X Ex II GD Ex de IIC T/T5, Ex td A T C/T5 C/T C IECEx Cert. No. IECEx BAS 5.8X Ex de IIC T/T5, Ex td A T C/T5 C/T C Zone & and Zone & *See Certified temperature below Brazilian (Inmetro) Certified: BR-Ex de IIB T/T. BR-Ex de IIC T5/T5 C GOST R Certification: Exde IIB T, Exde IIC T GOST K Certification: Exde IIB T, Exde IIC T Material: Body & Cover - UV stable, glass reinforced polyester. Outer flare - UV stable ABS. Mounting stirrup and fixtures in stainless steel. Finish: Natural black or painted or to client s requirements. Rated Power: 8 Watts RMS continuous (at 5 C). Output: IIB version: Maximum output at W/M is db(a) Maximum output at W/M is 9 db(a) Maximum output at 8W/M is db(a) IIC version: Maximum output at W/M is db(a) Maximum output at W/M is 6 db(a) Maximum output at 8W/M is 9 db(a) Frequency Range: Hz to 7kHz. Voice Coil Impedence: 8 ohms. Certified Temp: IIB version: Tamb - C to + C (T) and Tamb - C to + C (T) IIC version: Tamb - C to + C (T) and Tamb - C to + C (T5) Weight:.5kg approx Ingress Protection: IP66 Entries: ATEX & IEC x M ISO + x certified plug Terminals: x.mm. Mounting: Via Stirrup with ratchet facility Earth Continuity: Available Labels: Optional stainless steel tag and duty labels. : Used by combining the rated power tappings below. Ordering Requirements 8Ω Terminal tap change Direct 8ohm connection to driver, spare terminals if loop in/loop out required. SPL (db) Frequency 8W/M (DB V 8W unit) (/ Octave Pink Noise) ALL DIMENSIONS IN MILLIMETRES Frequency, Hz DB khz The following code is designed to help in selection of the correct unit. Build up the reference number by inserting the code for each component into the appropriate box. Model DB Certification Max Rated Power Options Finish Certification ATEX IIB ATEX IIC IECEx IIB IECEx IIC GOST 'R' IIB GOST 'R IIC GOST 'K' IIB GOST 'K' IIC Inmetro IIB Inmetro IIC Weatherproof Code BB BC JB JC GB GC KB KC MB MC W Power Code 8 Watts 8 Watts Code X* 8Ω version N * ATEX = V Line V Line available please specify. Option Code None N Duty label D* Tag label T* Earth continuity E * Please specify. Colour Code Natural Black N Red R Special S* * Please specify. All the above specifications, dimensions, weights and tolerances are nominal (typical) and Cooper MEDC reserve the right to vary all data without prior notice. No liability is accepted for any consequence of use. /

13 DBC Range - CEILING SPEAKERS Exde, Weatherproof Features Zone & and Zone & use Ex II GD BASEEFA certified GOST R & K certified Brazilian (Inmetro) certified IECEx Approved IP66 & IP67 Certified temperature C to + C* GRP and Flame-Retardant ABS corrosion free construction db (A) at watt at metre Power tappings via integral transformer Tool-free mounting method V or V line versions available Earth continuity available *Temperature class relates to ambient temperature (see over) Introduction This range of Ceiling-Mounted loudspeakers, intended for use in potentially explosive atmospheres, has a power rating of up to 8 Watts (upon request) and is suitable for use in the harsh environmental conditions found offshore and onshore in the oil, gas and petrochemical industries. The lightweight, patented design provides self-supporting and self-locking mounting onto a ceiling tile from.5 to 55mm thick. The speaker is held in the mount via a twist-fit support and locking grille, giving access from above or below and allowing first fit of either ceiling or speakers. The DBC s compact design will fit a ceiling cavity of limited space and its aesthetically pleasing appearance will enhance the surroundings. Cooper MEDC Limited, Colliery Road, Pinxton, Nottingham NG6 6JF, UK. Cooper MEDC (USA) North Sam Houston Parkway West Suite Houston, TX 786, USA Sales Enq. UK: + ()77 86 Sales Enq. USA: + (7) medc.sales@cooperindustries.com Web: medc.com 6DS9/B

14 Specification Certification: EN79-, EN79-, EN79-7 IEC79-, IEC79-, IEC79-7 and IEC 6-, IEC 6- IIB Version: ATEX Cert. No. Baseefa5ATEX98X Ex II G Ex de IIB T/T IECEx Cert. No. IECEx BAS 5.8X Ex de IIB T/T IIC Version: ATEX Cert. No. Baseefa5ATEX99X Ex II GD Ex de IIC T/T5, Ex td A T C/T5 C/T C IECEx Cert. No. IECEx BAS 5.8X Ex de IIC T/T5, Ex td A T C/T5 C/T C Zone & and Zone & GOST R Certification: Exde IIC T GOST K Certification: Exde IIC T Brazilian (Inmetro) Certified: BR-Ex de IIC T5/5 C Material: Body & Cover - Natural black, UV stable, glass reinforced polyester. Outer flare - UV stable ABS Finish: Natural ABS finish equivalent to RAL. Rated Power: Watts RMS continuous (at 5 C). Output: Maximum output at W/M is db(a) Maximum output at W/M is 6 db(a) *Other wattages available contact MEDC sales for details. Frequency Range: Hz to 7kHz. Voice Coil Impedence: 8 ohms. Certified Temp: - C to + C (T) and Tamb - C to + C (T5) Weight:.5kg approx Ingress Protection: IP66 & IP67 Entries: ATEX & IEC x M ISO + x certified plug Terminals: x.mm. Mounting: Via integral ceiling-mount bezel. Ceiling Cutout: Ø75mm. Earth Continuity: Available via optional earthing stud. : Used by combining the rated power tappings below. Power (Watts) Tappings (W unit) :. :. :. :.75 :.8 :. Tapping Options: Terminal tap change Ordering Requirements 8Ω Direct 8ohm connection to driver, spare terminals if loop in/loop out required. SPL (db) Frequency W/M (DBC V W unit) (/ Octave Pink Noise) ALL DIMENSIONS IN MILLIMETRES SPL@ W/M SPL@ W/M Frequency, Hz DBC khz The following code is designed to help in selection of the correct unit. Build up the reference number by inserting the code for each component into the appropriate box. Model DBC Certification Options Certification ATEX IIC IECEx IIC Inmetro IIC GOST R IIC GOST K IIC Code BC JC MC GC KC Code X* 8ohm version N *V Line Std V Line available please specify Options Code None N Tag label T* Earth continuity E * Please specify. All the above specifications, dimensions, weights and tolerances are nominal (typical) and MEDC reserve the right to vary all data without prior notice. No liability is accepted for any consequence of use. /

DB1 Range - HORNS - Up to 103 db(a)

DB1 Range - HORNS - Up to 103 db(a) DB1 Range - HORNS - Up to 103 db(a) Explosion-proof, Weatherproof Features UL listed Class I, Div. 1, Groups C & D. Class 1, Zone 1. ATEX approved. NEMA 4x, IP66. Certified temperature: 13 F to +158 F.

More information

MANUAL CALL POINT Intrinsically Safe (EExia), Weatherproof BG3 Range ATEX

MANUAL CALL POINT Intrinsically Safe (EExia), Weatherproof BG3 Range ATEX MAUAL CALL POIT Intrinsically Safe (EExia), Weatherproof BG3 Range ATEX ow Chinese Certified Introduction This manual fire alarm call point is designed in accordance with the latest draft European Call

More information

SOUNDERS Up to 113 db(a) EExd, Weatherproof DB1 Range

SOUNDERS Up to 113 db(a) EExd, Weatherproof DB1 Range SOUNDERS Up to 113 db(a) EExd, Weatherproof DB1 Range ATEX GOST Now UL & GOST Listed Introduction This range of light weight, flameproof Sounders has been designed with a high weatherproof rating to cope

More information

PRODUCT ATEX IECEx UL ULC CSA Inmetro CUTR CQST ABS SIL IP Rating Page DB7 66 / DB12 66 / DB15 66 / DB1 DB3 DB3V DB3B

PRODUCT ATEX IECEx UL ULC CSA Inmetro CUTR CQST ABS SIL IP Rating Page DB7 66 / DB12 66 / DB15 66 / DB1 DB3 DB3V DB3B Horns and Sounders The MEDC range of horns and sounders are suitable for a wide variety of applications and feature a variety of tone settings and traditional bells. Sounders and Horns are used to warn

More information

Manual Alarm Call Points

Manual Alarm Call Points Manual Alarm Call Points MEDC provide a range of manual alarm call points specifically designed for the purpose of raising an alarm in the case of an emergency in a hazardous area. The call points can

More information

Hazardous Area Ringers & Loudspeakers

Hazardous Area Ringers & Loudspeakers G U A R D I A N T E L E C O M Product and Services Guide Hazardous Area Ringers & Loudspeakers Loudspeakers and Ringers that are designed and manufactured to meet the demands of Hazardous Areas where ignitable

More information

Beacons, Lights & Strobes

Beacons, Lights & Strobes Beacons, Lights & Strobes MEDC's range of beacons, including flashing, steady-state indicators and rotating units, provide solutions for potentially explosive and harsh environmental conditions. These

More information

Fire Alarm or Emergency Call Points

Fire Alarm or Emergency Call Points Class I, Div. 2, Zone 2 Touch-safe coated glass for finger activation. Class I, Div. 2, Zone 2 Push to activate. Class I, Div. 1 Push to activate. Key switch to reset. These manual fire alarm call points

More information

JUNCTION BOXES EExe Increased Safety & Weatherproof JB10 & JB11 Ranges ATEX. Introduction

JUNCTION BOXES EExe Increased Safety & Weatherproof JB10 & JB11 Ranges ATEX. Introduction JUNCTION BOXES EExe Increased Safety & Weatherproof JB10 & JB11 Ranges Introduction These GRP terminal boxes have been designed for use in hazardous and hostile environments. The robust design, coupled

More information

GRP Flameproof Combination Signal db(a) / 5 Joule Series YL6S

GRP Flameproof Combination Signal db(a) / 5 Joule Series YL6S www.stahl.de > Corrosion resistant omnidirectional high output sounder > Integrated Ex d enclosure > Extreme temperature range > 3 stage alarm with independant tone selection for V DC systems > IP66 IP67

More information

New Product Showcase. Introducing the latest additions to the MEDC product range.

New Product Showcase. Introducing the latest additions to the MEDC product range. New Product Showcase Introducing the latest additions to the MEDC product range. Shell Kittiwake photographic services / Shell International Statoil Norne FPSO Kenneth Engelsvold/Statoil The safety you

More information

Flameproof Manual Call Points Series MCP

Flameproof Manual Call Points Series MCP > Light weight glass reinforced polyester (GRP) Ex d enclosure > Weather resistant high performance red paint finish as standard > Break glass version supplied with test key > Push button version supplied

More information

INERIS 01ATEX0060 (standard) TR CU (marking upon request, ordering code to be required)

INERIS 01ATEX0060 (standard) TR CU (marking upon request, ordering code to be required) FLUORESCENT LIGHTING RMS-560.. Series - Fluorescent lighting fixtures TECHNICAL FEATURES RMS.. series lighting fixtures are ideally suited for ON and OFF-SHORE applications and all kinds of industries

More information

Telephony & Communication

Telephony & Communication Telephony & Communication Avertisseurs sonore et visuel Détecteur Communication Eclairage Equipement d installation Contrôle commande for Industry and Hazardous Product at a Glance Telephone I Mobile phone

More information

EVL-B - Zone 1, 2, 21, 22 - Replaces traditional discharge lamps more than 400W - Saves in energy, maintenance and installation

EVL-B - Zone 1, 2, 21, 22 - Replaces traditional discharge lamps more than 400W - Saves in energy, maintenance and installation EVL-B Shock-resistant tempered glass - Zone 1, 2, 21, 22 - Replaces traditional discharge lamps more than 400W - Saves in energy, maintenance and installation costs - Suitable for GAS category IIC LED

More information

Hazardous Area Signalling

Hazardous Area Signalling Hazardous Area Signalling Model# Combination Alarm Horn Sounders and Beacons/Lights Approval Enclosure Zone / Division IS-mC1 L.E.D. 37 BExCS110-05 Xenon 5 BExCS110 -L2 L.E.D. 5 D1xC1X05R Xenon 17 D1xC1X10R

More information

INSTRUCTION & SERVICE MANUAL

INSTRUCTION & SERVICE MANUAL INSTRUCTION & SERVICE MANUAL D2xC1 ALARM HORN AND STROBE For Use In Hazardous Locations 3) Ratings and Markings 3.1 ATEX / IECEx certification The D2xC1 Alarm Horn and Strobe complies with the following

More information

Integrated Solutions Low Voltage Systems

Integrated Solutions Low Voltage Systems Integrated Solutions Low Voltage Systems 612 Contents Energy Distribution Overview Module Technology 8146 614 Overview Flameproof Enclosures 8220 614 Overview Flameproof Enclosures 8261 614 Overview CUBEx

More information

Technical Manual for the Horn DB1P UL DB1HP UL

Technical Manual for the Horn DB1P UL DB1HP UL Technical Manual for the Horn DB1P UL DB1HP UL Please note that every care has been taken to ensure the accuracy of our technical manual. We do not, however, accept responsibility for damage, loss or expense

More information

ARRAN LED LED FLOODLIGHT. Standard Specification. Features

ARRAN LED LED FLOODLIGHT. Standard Specification. Features ARRAN LED LED FLOODLIGHT The Arran LED floodlight range is low energy with an instant on output and up to 130,000 maintenance free hours. Specifically designed for applications where moisture, dirt or

More information

LC1 Modular Ceiling Loudspeaker Range. en Installation note

LC1 Modular Ceiling Loudspeaker Range. en Installation note LC1 Modular Ceiling Loudspeaker en Installation note LC1 Modular Ceiling Loudspeaker Table of Contents en 3 Table of contents 1 System Overview 4 1.1 Housings 4 1.2 Loudspeakers 5 1.3 Accessories 6 2

More information

PRODUCT OVERVIEW. Light fittings, boxes & custom built control panels for explosive atmospheres

PRODUCT OVERVIEW. Light fittings, boxes & custom built control panels for explosive atmospheres PRODUCT OVERVIEW Light fittings, boxes & custom built control panels for explosive atmospheres LIGHT FITTINGS, BOXES & CUSTOM BUILT CONTROL PANELS FOR EXPLOSIVE ATMOSPHERES Light fittings for all zones

More information

Technical Manual for the Alarm Pull Station PH1

Technical Manual for the Alarm Pull Station PH1 Technical Manual for the Alarm Pull Station PH1 Please note that every care has been taken to ensure the accuracy of our technical manual. We do not, however, accept responsibility for damage, loss or

More information

EJBX. Ex d. AISI 316L stainless steel. - Zone 1, 2, 21, 22 - Group IIB+H2 - Stainless steel junction boxes - Choice of 13 sizes - IP 66 / 67

EJBX. Ex d. AISI 316L stainless steel. - Zone 1, 2, 21, 22 - Group IIB+H2 - Stainless steel junction boxes - Choice of 13 sizes - IP 66 / 67 Ex d EJBX AISI 316L stainless steel - Zone 1, 2, 21, 22 - Group IIB+H2 - Stainless steel junction boxes - Choice of 13 sizes - IP 66 / 67 Quartz sand blasting Warning labels Mounting bracket Silicone gasket

More information

High bay LED lighting fixture

High bay LED lighting fixture Supporting bracket EWL - Zone 1, 2, 21, 22 - Replacing traditional discharge lamps of up to 750W - Savings in energy, maintenance and installation costs - Instant, brilliant illumination - Suitable for

More information

Hazardous Area Portable Fan Heater The Bulldog

Hazardous Area Portable Fan Heater The Bulldog Hazardous Area Portable Fan Heater The Bulldog www.exheat-industrial.com MFH The Bulldog Portable Fan Heater EXHEAT Industrial s MFH The Bulldog Portable Fan Heater is the world s first truly portable

More information

Explosion Proof Manual Call Points Series MCP

Explosion Proof Manual Call Points Series MCP > Light weight glass reinforced polyester (GRP) Ex d enclosure > Weather resistant high performance red paint finish as standard > Break glass version supplied with test key > Push button version supplied

More information

WE PROTECT HAZARDOUS ENVIRONMENTS EXPLOSION-PROOF AND HAZARDOUS LOCATION VISUAL & AUDIBLE SIGNALING PRODUCTS

WE PROTECT HAZARDOUS ENVIRONMENTS EXPLOSION-PROOF AND HAZARDOUS LOCATION VISUAL & AUDIBLE SIGNALING PRODUCTS WE PROTECT HAZARDOUS ENVIRONMENTS EXPLOSION-PROOF AND HAZARDOUS LOCATION VISUAL & AUDIBLE SIGNALING PRODUCTS 100+ YEARS Federal Signal is recognized as one of the industry s leading suppliers of safety

More information

Industrial Signalling

Industrial Signalling Industrial Signalling Introduction Introduction Klaxon Signals manufactures the world s largest range of sound signalling equipment and solutions for the European and worldwide market place. Product Range

More information

UL HAZARDOUS LOCATIONS SERVICES

UL HAZARDOUS LOCATIONS SERVICES UL HAZARDOUS LOCATIONS SERVICES The international preference in hazardous locations certification for over 100 years ul.com/hazloc Explosive Gas Atmospheres Class I Division S Includes flammable gases,

More information

standards: standards:

standards: standards: INSTRUCTION MANUAL D2xB1LD2 LED Beacons For use in Hazardous Locations 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT DO NOT OPEN WHEN ENERGISED POTENTIAL ELECTROSTATIC CHARGING HAZARD

More information

Officine Meccaniche M.A.M. series for command, control, signaling and/or automation. DOCUMENT IS-EJB-A-14 rev. 0

Officine Meccaniche M.A.M. series for command, control, signaling and/or automation. DOCUMENT IS-EJB-A-14 rev. 0 Officine Meccaniche M.A.M. Apparecchiature Antideflagranti DOCUMENT IS-EJB-A-14 rev. 0 Instructions Flameproof enclosures EJB../W series for command, control, signaling and/or automation Emission date:

More information

CCA-03EX. - Easy installation - Low energy consumption - New COB LED technology - Zone 1, 2, 21, 22. Directional LED spotlights

CCA-03EX. - Easy installation - Low energy consumption - New COB LED technology - Zone 1, 2, 21, 22. Directional LED spotlights CCA-03EX - Easy installation - Low energy consumption - New COB LED technology - Zone 1, 2, 21, 22 Directional LED spotlights Body and lid in coated aluminium LED for proper operation monitoring 127 ED.2018

More information

Hazardous Area Portable Fan Heater The Bulldog

Hazardous Area Portable Fan Heater The Bulldog Hazardous Area Portable Fan Heater The Bulldog www.exheat-industrial.com MFH The Bulldog Portable Fan Heater EXHEAT Industrial s MFH The Bulldog Portable Fan Heater is the world s first truly portable

More information

INSTRUCTION MANUAL. E2xB05 & E2xB10 Xenon Beacons For use in Hazardous Locations

INSTRUCTION MANUAL. E2xB05 & E2xB10 Xenon Beacons For use in Hazardous Locations INSTRUCTION MANUAL E2xB05 & E2xB10 Xenon Beacons For use in Hazardous Locations 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT DO NOT OPEN WHEN ENERGISED POTENTIAL ELECTROSTATIC CHARGING

More information

CCAC. Ex d. - Zone 1, 2, 21, 22 - Group IIC - Aluminium junction boxes - Choice of 5 sizes - IP66. Stainless steel bolts.

CCAC. Ex d. - Zone 1, 2, 21, 22 - Group IIC - Aluminium junction boxes - Choice of 5 sizes - IP66. Stainless steel bolts. Ex d CCAC - Zone 1, 2, 21, 22 - Group IIC - Aluminium junction boxes - Choice of 5 sizes - IP66 Stainless steel bolts Polyester coating External earth screw Grub screws for opening lid External earth screw

More information

TECHNICAL MANUAL EXPLOSION PROOF STATUS LIGHT / LAMP BSL 125 / BSL 150. Scope: EXcite USER MANUAL BSL 125 / BSL 150. Date:

TECHNICAL MANUAL EXPLOSION PROOF STATUS LIGHT / LAMP BSL 125 / BSL 150. Scope: EXcite USER MANUAL BSL 125 / BSL 150. Date: Page 1 of 9 TECHNICL MNUL EXPLOSION PROOF STTUS LIGHT / LMP TEX Marking: Code: II 2GD EPL Gb, Db Ex d IIC T4/T5/T6 IP66 Ex tb IIIC TXXX C Marking details: Please note that every care has been taken to

More information

Hazardous Area Portable Fan Heater The Bulldog

Hazardous Area Portable Fan Heater The Bulldog Hazardous Area Portable Fan Heater The Bulldog www.exheat-industrial.com MFH The Bulldog Portable Fan Heater EXHEAT Industrial s MFH The Bulldog Portable Fan Heater is the world s first truly portable

More information

SafeSite LED Area Light - ATEX / IECEx. for Indoor and Outdoor Industrial Applications

SafeSite LED Area Light - ATEX / IECEx. for Indoor and Outdoor Industrial Applications SafeSite LED Area Light - ATEX / IECEx for Indoor and Outdoor Industrial Applications On when it matters most. Products and solutions that protect your business 2 Features & Benefits 5 year warranty L70

More information

DTS Light fittings for explosive atmospheres

DTS Light fittings for explosive atmospheres DTS Light fittings for explosive atmospheres For all zones and industrial applications LIGHT FITTINGS FOR EXPLOSIVE ATMOSPHERES Light fittings for all zones and industrial applications Tubular glass light

More information

Sensepoint. Fit For Purpose Flammable, toxic and Oxygen versions available High performance, low cost Suitable for new and retro fit applications

Sensepoint. Fit For Purpose Flammable, toxic and Oxygen versions available High performance, low cost Suitable for new and retro fit applications Sensepoint The Sensepoint range of flammable, toxic and Oxygen gas detectors offer users a high quality, low cost solution to their industrial gas monitoring needs. Sensepoint Fit For Purpose Flammable,

More information

SONANCE PROFESSIONAL SERIES

SONANCE PROFESSIONAL SERIES PROFESSIONAL SERIES SURFACE MOUNT SPEAKER PS-S3T Introducing the Sonance Professional Series From Sonance, the company that created the architectural audio category comes a range of professional loudspeakers

More information

BS-1015BSW. WARNING Indicates a potentially hazardous situation which, if mishandled, could result in death or serious personal injury.

BS-1015BSW. WARNING Indicates a potentially hazardous situation which, if mishandled, could result in death or serious personal injury. INSTRUCTION MANUAL COMPACT SPEAKERS BS-1015BSB BS-1015BSW Thank you for purchasing TOA's Compact Speaker. Please carefully follow the instructions in this manual to ensure long, trouble-free use of your

More information

SONANCE PROFESSIONAL SERIES

SONANCE PROFESSIONAL SERIES PROFESSIONAL SERIES SURFACE MOUNT SPEAKER PS-S63T Introducing the Sonance Professional Series From Sonance, the company that created the architectural audio category comes a range of professional loudspeakers

More information

Micro and Mini Torch. Zones: 0, 1, 2, 20, 21 and 22. Product Overview. Features & Benefits. Certifications

Micro and Mini Torch. Zones: 0, 1, 2, 20, 21 and 22. Product Overview. Features & Benefits. Certifications Micro and Mini Zones: 0, 1, 2, 20, 21 and 22 Product Overview Features & Benefits The Micro and Mini es use high-tech light sources to give impressive performance with a compact size, designed for easy

More information

Flameproof Manual Call Points Series MCP

Flameproof Manual Call Points Series MCP > Light weight glass reinforced polyester (GRP) Ex d enclosure > Weather resistant high performance red paint finish as standard > Break glass version supplied with test key > Push button version supplied

More information

INSTRUCTION MANUAL. D2xB1XH1 & D2xB1XH2 Xenon Beacons For use in Hazardous Locations

INSTRUCTION MANUAL. D2xB1XH1 & D2xB1XH2 Xenon Beacons For use in Hazardous Locations INSTRUCTION MANUAL D2xB1XH1 & D2xB1XH2 Xenon Beacons For use in Hazardous Locations synchronization requirements of UL1971 & UL1638 / CAN/ULCS526. 2.2 NEC & CEC Class / Division Ratings for US / Canada

More information

INSTRUCTION MANUAL (ATEX / IECEx)

INSTRUCTION MANUAL (ATEX / IECEx) INSTRUCTION MANUAL (ATEX / IECEx) BExS110D and BExS110D-R Sounder For use in Flammable Gas and Dust Atmospheres BExS110D BExS110D-R 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT DO NOT

More information

Explosion Proof Combination Signal db (A) / 5 Joule Series YL60

Explosion Proof Combination Signal db (A) / 5 Joule Series YL60 www.stahl.de Explosion Proof Combination Signal - 110 db (A) / 5 Joule > Omnidirectional high output sounder 110 db (A) / 1 m > 5 Joule xenon strobe > 2 stage alarm, independently selectable 2nd stage

More information

Cable Glands. Description Introduction to Cable Glands 399. EEXe Series EEXe Series. A2F, E1FX/E2FX, E1FW/E2FW and T3 Series

Cable Glands. Description Introduction to Cable Glands 399. EEXe Series EEXe Series. A2F, E1FX/E2FX, E1FW/E2FW and T3 Series Description Page Introduction to Cable Glands 399 EEXe Series 400-401 Polyamide Cable Glands for Unarmored Cable Increased Safety EEXe Series Ex e Certified Ex I Application Entry Thread Seal A2F, E1FX/E2FX,

More information

Ex LED light fittings

Ex LED light fittings About us TEP Ex is a regional leader in manufacturing of explosion-protected electrical equipment. Through continuous development of new products and markets, modernization of technology and investment

More information

POINT STATUS LIGHTS PSL LED HELIDECK STATUS LIGHT SYSTEM SAFE AREA & CLASS I, DIVISION 2 (ZONE 2)

POINT STATUS LIGHTS PSL LED HELIDECK STATUS LIGHT SYSTEM SAFE AREA & CLASS I, DIVISION 2 (ZONE 2) NEW SAFETY FEATURE AVAILABLE SYNCHRONIZED FLASHING RED PERIMETER LIGHTS & MAIN LIGHTS GREEN TO RED COLOR SWITCHING PERIMETER LIGHTS INTEGRATED WITH THE STATUS LIGHT SYSTEM Compliances: ETL Listed to UL

More information

Circulation Heaters Selection Guidelines

Circulation Heaters Selection Guidelines Selection Guidelines Selecting a Circulation Heater Application Factors Corrosion Policy Selecting the proper circulation heater component requires critical engineering judgement and careful evaluation

More information

A guide to the use of electrical equipment in potentially explosive atmospheres To view this document in PDF format click here.

A guide to the use of electrical equipment in potentially explosive atmospheres To view this document in PDF format click here. A guide to the use of electrical equipment in potentially explosive atmospheres To view this document in PDF format click here Introduction Potentially Explosive Atmospheres exist where there is a risk

More information

INSTRUCTION MANUAL (ATEX / IECEx)

INSTRUCTION MANUAL (ATEX / IECEx) INSTRUCTION MANUAL (ATEX / IECEx) BExBG15E and BExBG10E Flameproof / Increased Safety Xenon Beacons For use in Flammable Gas and Dust Atmospheres 1) Introduction The BExBG15E and BExBG10E beacons are flameproof

More information

HDL106 LED LUMINAIRES. For Harsh & Hazardous Environments.

HDL106 LED LUMINAIRES. For Harsh & Hazardous Environments. HDL106 LED LUMINAIRES For Harsh & Hazardous Environments www.chalmit.com Quality, Reliability and Low Maintenance Our LED Product Range Chalmit has over a century s worth of experience in providing cutting

More information

Enclosure Heaters. Zone 1, Zone 2 & Safe Area

Enclosure Heaters. Zone 1, Zone 2 & Safe Area Enclosure Heaters Zone 1, Zone 2 & Safe Area CONTACT INFORMATION OFFSHORE SOLUTIONS Subject to change without prior notice TPS2121 REV. D 22.08.2017 Kjetil Tengesdal Sales Director Offshore Solutions Special

More information

The CMS 801 SUB BM is a compact 400Watt subwoofer that complements the

The CMS 801 SUB BM is a compact 400Watt subwoofer that complements the Product Information Document Compact ceiling subwoofer for installation applications 100 Watts continuous, 400 Watts peak power 8" long excursion driver for greater low frequency response Blind mount version

More information

SafeSite LED Area Light - IECEx / ATEX for Indoor and Outdoor Hazardous Areas. Patent Pending

SafeSite LED Area Light - IECEx / ATEX for Indoor and Outdoor Hazardous Areas. Patent Pending SafeSite LED Area Light - IECEx / ATEX for Indoor and Outdoor Hazardous Areas About Dialight Dialight (LSE: DIA.L) is leading the energy efficient LED lighting revolution around the world for industrial

More information

PROFESSIONAL SERIES IN-CEILING LOW PROFILE SPEAKER PS-C43RTLP

PROFESSIONAL SERIES IN-CEILING LOW PROFILE SPEAKER PS-C43RTLP PROFESSIONAL SERIES IN-CEILING LOW PROFILE SPEAKER PS-C43RTLP Introducing the Sonance Professional Series From Sonance, the company that created the architectural audio category comes a range of professional

More information

BS-678BSW. WARNING Indicates a potentially hazardous situation which, if mishandled, could result in death or serious personal injury.

BS-678BSW. WARNING Indicates a potentially hazardous situation which, if mishandled, could result in death or serious personal injury. INSTRUCTION MANUAL WALL MOUNT SPEAKERS BS-678BSB BS-678BSW Thank you for purchasing TOA's Wall Mount Speaker. Please carefully follow the instructions in this manual to ensure long, trouble-free use of

More information

Multiple Status Indicators Series MEXE, MS25, MS35, MS45, MS55

Multiple Status Indicators Series MEXE, MS25, MS35, MS45, MS55 www.stahl.de > Pre-wi ready-to-use multi-signalling unit > Corrosion resistant > Suitable for offshore / onshore harsh environments > Incorporates the FX15 GRP beacon YA90 for visual audible notification

More information

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres 1) Introduction The BExBG05D-SIL is a flameproof beacon which is certified

More information

WELCOME TO HAWKE INTERNATIONAL INTERACTIVE CATALOGUE

WELCOME TO HAWKE INTERNATIONAL INTERACTIVE CATALOGUE WELCOME TO HAWKE INTERNATIONAL INTERACTIVE CATALOGUE This interactive catalogue has been designed with ease of use in mind.the pages are interactive and contain links or 'hotspots' that can be clicked

More information

Premium Cabinet Loudspeakers. Installation manual

Premium Cabinet Loudspeakers. Installation manual Premium Cabinet Loudspeakers en Installation manual Premium Cabinet Loudspeakers Table of Contents en 3 Table of contents 1 Safety 4 1.1 Suspension 4 1.2 Notices 4 2 Short information 5 3 Introduction

More information

NexLED. Ex e LED BULKHEAD. Features. Standard Specification. International Approvals. NexLED with Exit Sign kit

NexLED. Ex e LED BULKHEAD. Features. Standard Specification. International Approvals. NexLED with Exit Sign kit NexLED Ex e LED BULKHEAD 62 NexLED with Exit Sign kit The NexLED bulkhead utilises the latest LED technology to provide instant illumination. The NexLED requires no re-lamping making it virtually maintenance

More information

CE110I. Piezoelectric accelerometer with integrated electronics. IECEx

CE110I. Piezoelectric accelerometer with integrated electronics. IECEx Piezoelectric accelerometer with integrated electronics FEATURES» From the Vibro-Meter product line» Designed for medium temperature industrial applications: 55 to 115 C» Sensitivity: 100 mv/ g» Frequency

More information

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required Sieger Sensepoint The Sensepoint range of flammable, toxic and oxygen gas detectors offer users a high quality, low cost solution to their industrial gas monitoring needs. Sieger Sensepoint Fit For Purpose

More information

Certification Supplement Manual

Certification Supplement Manual PROCESS ANALYSERS SERVOTOUGH FluegasExact (2700) Gas Analyser Certification Supplement Manual Part Number: 02700008D Revision: 2 Language: UK English Blank CONTENTS 1 INTRODUCTION 2 EC DECLARATION OF CONFORMITY

More information

EVLPF Series Compact Fluorescent

EVLPF Series Compact Fluorescent EVLPF Series Low Profile Hazard Gard Luminaires Cl. I, Div. 1, Groups B (GB Suffix), C, D Cl. I, Zone 1, Groups IIB + H2 (GB Suffix), IIB, IIA Cl. II, Div. 1, Groups E, F, G Class III, Simultaneous Presence

More information

PROFESSIONAL SERIES IN-CEILING PS-C63RT. Introducing the Sonance Professional Series. Features & Benefits. Applications SONANCE PROFESSIONAL SERIES 1

PROFESSIONAL SERIES IN-CEILING PS-C63RT. Introducing the Sonance Professional Series. Features & Benefits. Applications SONANCE PROFESSIONAL SERIES 1 PROFESSIONAL SERIES IN-CEILING SPEAKER PS-C63RT Introducing the Sonance Professional Series From Sonance, the company that created the architectural audio category comes a range of professional loudspeakers

More information

LB3 Premium Cabinet Loudspeakers

LB3 Premium Cabinet Loudspeakers LB3 Premium Cabinet Loudspeakers LB3-PC2, LB3-PC3, LM1-MBx12/1 en Installation note LB3 Premium Cabinet Loudspeakers Important safeguards en 3 1 Important safeguards Always mount the loudspeakers securely

More information

Continuous level measurement Ultrasonic transmitters

Continuous level measurement Ultrasonic transmitters Overview Configuration Parabolic mounting is a 2-wire loop powered ultrasonic transmitter for level, volume and flow monitoring of liquids in open channels, storage vessels, and simple process vessels.

More information

PROFESSIONAL SERIES IN-CEILING PS-C43RT. Introducing the Sonance Professional Series. Features & Benefits. Applications SONANCE PROFESSIONAL SERIES 1

PROFESSIONAL SERIES IN-CEILING PS-C43RT. Introducing the Sonance Professional Series. Features & Benefits. Applications SONANCE PROFESSIONAL SERIES 1 PROFESSIONAL SERIES IN-CEILING SPEAKER PS-C43RT Introducing the Sonance Professional Series From Sonance, the company that created the architectural audio category comes a range of professional loudspeakers

More information

Industrial Signalling. Signalling Solutions

Industrial Signalling. Signalling Solutions Industrial Signalling Signalling Solutions Introduction Introduction Klaxon Signals manufactures the world s largest range of sound signalling equipment and solutions for the European and worldwide market

More information

Portable ATEX Heater. Defend Against Cold. T: +44 (0)

Portable ATEX Heater. Defend Against Cold. T: +44 (0) Portable ATEX Heater T: +44 (0) 191 490 1547 northernsales@thorneandderrick.co.uk Defend Against Cold www.thorneandderrick.com Portable ATEX Heater... Many Problems......One Solution The Problem Low temperatures

More information

Cornered Ci2. Description FEATURES. 2 1/2 woofer 3/4 dome tweeter Triangular ABS cabinet IP54 rated Mounts without brackets Hidden cable connection

Cornered Ci2. Description FEATURES. 2 1/2 woofer 3/4 dome tweeter Triangular ABS cabinet IP54 rated Mounts without brackets Hidden cable connection Cornered Ci2 FEATURES 2 1/2 woofer 3/4 dome tweeter Triangular ABS cabinet IP54 rated Mounts without brackets Hidden cable connection COLOURS Description DATA Ci2 is an ultra compact 2-way full-range speaker

More information

INSTRUCTION MANUAL (ATEX/IECEx/SIL2)

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExS110D-SIL Flameproof Sounders For use in Flammable Gas Atmospheres BExS110D-SIL 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT DO NOT OPEN WHEN

More information

Level instruments. Continuous level measurement - Ultrasonic transmitters. SITRANS Probe LU. Overview. Configuration

Level instruments. Continuous level measurement - Ultrasonic transmitters. SITRANS Probe LU. Overview. Configuration Overview Configuration is a 2-wire loop powered ultrasonic transmitter for level, volume and flow monitoring of liquids in open channels, storage vessels and simple process vessels. Benefits Continuous

More information

Phoenix Explosion-proof. Pan & Tilt heads and Camera Housings for potentially exposed environments. Answers for infrastructure.

Phoenix Explosion-proof. Pan & Tilt heads and Camera Housings for potentially exposed environments. Answers for infrastructure. Phoenix Explosion-proof Pan & Tilt heads and Camera Housings for potentially exposed environments Answers for infrastructure. Video monitoring under extreme conditions Security Products from Siemens is

More information

SI 3C LP. 4" Low Profile Back Can. Speakers. n 3" (7.6 cm) full-range driver with a tuned port

SI 3C LP. 4 Low Profile Back Can. Speakers.  n 3 (7.6 cm) full-range driver with a tuned port Speakers Full-range Ceiling Speakers with 4" Low Profile Back Can n 3" (7.6 cm) full-range driver with a tuned port n 4" (1.2 cm) deep low profile metal back can for plenum environments n Wide 17 conical

More information

High Quality LED Lighting!

High Quality LED Lighting! High Quality LED Lighting! IP65 GB Code: Ex ib II CT4 GB Certificate CNEx09.0865 Standard: GB3836.1-2000 GB3836.4-2000 Cree LED Light Source PC Shell Portable Mountable on a safety helmet Energy Saving

More information

Guide for hazardous areas

Guide for hazardous areas Guide for hazardous areas 1 Hazardous areas definitions 2 Gas and dust s 3 Temperature classifications 4 Common flammable gases, vapours and dust types 5 Protection concepts ATEX and IECEx 6 Protection

More information

DICTATOR Hold-Open Systems for Hazardous Areas

DICTATOR Hold-Open Systems for Hazardous Areas DICTATOR for Hazardous Areas Products to be used in hazardous areas obviously have to meet special demands. The European ATEX directives (first the EN 94/9/EG and then the directive 2014/34/ EU) brought

More information

Operating Instructions

Operating Instructions Important information: These instructions contain safety information, read and follow them carefully. Dialight will not accept any responsibility for injury, damage or loss which may occur due to incorrect

More information

ATEX. IECEx. culs GOST-R. VdS

ATEX. IECEx. culs GOST-R. VdS 1. Hazardous Area Signalling 1.11 Intrinsic safety: Visual 1.12 Intrinsic safety: Audible 1.13 Intrinsic safety: Combination 1.14 Intrinsic safety: Manual Call Points 1.21 Explosion / flame proof: Visual

More information

official distributor of Newson Gale Ltd.

official distributor of Newson Gale Ltd. Continuous Ground Loop Monitoring with visual indication. The precision and reliability of the provides enhanced safety and security by continuously testing the connection of the clamp to the container

More information

INSTRUCTION & SERVICE MANUAL D1xS1 & D1xS2 ALARM HORNS For Use In Hazardous Locations - Gas

INSTRUCTION & SERVICE MANUAL D1xS1 & D1xS2 ALARM HORNS For Use In Hazardous Locations - Gas INSTRUCTION & SERVICE MANUAL D1xS1 & D1xS2 ALARM HORNS For Use In Hazardous Locations - Gas UL 1203 CSA C22.2 NO. 30-M1986 The D1xS1 and D1xS2 Alarm Horns also comply with the following standards for signaling

More information

Sensepoint. Fit For Purpose Flammable, toxic and oxygen versions available High performance, low cost Suitable for new and retro fit applications

Sensepoint. Fit For Purpose Flammable, toxic and oxygen versions available High performance, low cost Suitable for new and retro fit applications Sensepoint The Sensepoint range of flammable, toxic and oxygen gas detectors offer users a high quality, low cost solution to their industrial gas monitoring needs. Sensepoint Fit For Purpose Flammable,

More information

WIDE RANGE SPEAKER INSTRUCTION MANUAL TABLE OF CONTENTS

WIDE RANGE SPEAKER INSTRUCTION MANUAL TABLE OF CONTENTS INSTRUCTION MANUAL WIDE RANGE SPEAKER CS-64BS TABLE OF CONTENTS 1. SAFETY PRECAUTIONS... 2 2. GENERAL DESCRIPTION AND FEATURES... 3 3. IMPEDANCE CHANGE... 3 4. WIRING 4.1. When No Bridge Connection is

More information

USER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 218

USER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 218 CONTENT 1. Manufacturer 1 2. General safety informations 1 3. Purpose 2 4. Product compliance 2 5. Degree of protection and technical data 2 6. Type 3 7. Mounting and installation 3 8. Dimensions 6 9.

More information

LB3 Premium Cabinet Loudspeakers

LB3 Premium Cabinet Loudspeakers LB3 Premium Cabinet Loudspeakers LB3-PC2, LB3-PC3, LM1-MBx12/1 en Installation note LB3 Premium Cabinet Loudspeakers Important safeguards en 3 1 Important safeguards Always mount the loudspeakers securely

More information

INSTRUCTION MANUAL TABLE OF CONTENTS

INSTRUCTION MANUAL TABLE OF CONTENTS INSTRUCTION MANUAL WIDE RANGE SPEAKER CS-154BS TABLE OF CONTENTS 1. SAFETY PRECAUTIONS... 2 2. GENERAL DESCRIPTION AND FEATURES... 3 3. IMPEDANCE CHANGE... 4 4. WIRING 4.1. When No Bridge Connection is

More information

ELECTRICAL EX EQUIPMENT

ELECTRICAL EX EQUIPMENT ELECTRICAL EX EQUIPMENT in hazardous areas Enclosures Reliable Customized Solutions Leader in Explosion Proof Protections CB Control Panel Configuration - Gas group IIB / Dust group IIIC Ex d enclosures

More information

Hazardous Area LED Lighting Hazard Gard LED Luminaires. Hazard Gard EVLL LED

Hazardous Area LED Lighting Hazard Gard LED Luminaires. Hazard Gard EVLL LED Hazardous Area LED Lighting Hazard Gard LED Luminaires Hazard Gard EVLL LED Hazard Gard EVLL LED Safe. Reliable. Efficient. Featuring the industry's broadest range of LED luminaires for harsh and hazardous

More information

Approved by: Document no.: EGT

Approved by: Document no.: EGT ET Page 1 of 6 TECHNICL MNUL EXPLOSION PROOF MNUL CLL POINT / PUSH BUTTON TEX Marking: Code: II 2D EPL b, Db Ex d IIC T6 IP66 Ex tb IIIC T85 C Marking details: Please note that every care has been taken

More information

INSTRUCTION & SERVICE MANUAL

INSTRUCTION & SERVICE MANUAL INSTRUCTION & SERVICE MANUAL D1xC COMBINED RADIAL HORNS & STROBES For Use In Hazardous Locations - Gas 3) Ratings and Markings The D1xC1 and D1xC2 combined alarm horns and strobes comply with the following

More information

OPERATING AND INSTALLATION

OPERATING AND INSTALLATION A division of Signature Ind. Ltd YO6 YL6 V6 DIMENSIONS (mm) 280mm 11 OPERATING AND INSTALLATION INSTRUCTIONS FOR (UL & ATEX) YODALEX FLAMEPROOF AUDIBLE AND VISUAL ALARMS D7292 OPERATING CLASS 1 DIVISION

More information

USER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 236

USER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 236 CONTENT 1. Manufacturer 1 2. General safety informations 1 3. Purpose 2 4. Product compliance 2 5. Degree of protection and technical data 2 6. Type 3 7. Mounting and installation 3 8. Dimensions 6 9.

More information

BC9700 series High Power LED Explosion Proof Light

BC9700 series High Power LED Explosion Proof Light BC9700 series High Power LED Explosion Proof Light Characteristics IECEx ATEX LM79 LM8 IP 66 Ta 0/55 Ta -0 Application Zone,zone ;zone,zone Suitable for Low installation height in Moist corrosive environment,such

More information