Murco Core Product Guide Gas Leak Detection Solutions for all your building needs

Size: px
Start display at page:

Download "Murco Core Product Guide Gas Leak Detection Solutions for all your building needs"

Transcription

1 Murco Core Product Guide Gas Leak Detection Solutions for all your building needs Refrigerant Gases Toxic Gases Combustible Gases VOC s Legislation: F Gas Regulation, EH40 Standards: EN378 Lloyds Approval (MGD) Regulatory Approvals: UL, CE, CSA, IEC and EN

2 Fixed Gas Detectors MGD-MURCO GAS DETECTOR & Standard Plus 1-2 Channel Or 3-6 Channel Long-life semi-conductor sensors for detection of most halocarbon refrigerants (HFC, HCFC, CFC), ammonia, hydrocarbons, combustibles and VOC gases. Infrared sensors can detect CO2 and selected hydrocarbons Quick and easy installation of a stand-alone detector with controller s monitored by a central controller with an on-board buzzer and LED alarm indicators High/Low volt-free relays for turning on fans, alarms or connecting with BMS/SCADA systems Multi- options allows for the detection of different gases in one system The most cost effective system available select from 1 to 6 remote sensors with 1 or 2 levels of alarm Optional Relay expander box for additional relays to switch on individual sensor alarms Robust IP66 enclosure allows units to be placed directly in areas where detection is needed A scalable gas detection system for reliable real-time monitoring that alarms when pre-set thresholds are exceeded Ideal for Chiller Rooms Supermarkets Brewing Industrial Refrigeration Food Storage/Processing Technology s 230V ac. 50Hz/120V ac. 60 Hz/12V dc. 1 or 2 1 or 2 (volt free) Semiconductor + Infrared 7 (refer to back page) and can integrate into BMS IAM INTEGRATED AREA MONITOR with 1 Optional Standard Remote / Faceplate Option Long life semiconductor sensors for the detection of most halocarbon refrigerants, hydrocarbons, ammonia, VOC s and combustible gases Ideal for VRV or Air Conditioning Systems where thousands of sensors may be required A competitively priced, easy to use, stand-alone system Optional IAM C control panel allows connection of up to 16 sensors per panel which can be pyramided for system expansion. 2 volt-free relays connect to activate alarms/shut down off valves Filtered sensors and selectable delays eliminate false alarms Ideal for public areas with an optional remote sensor/faceplate Ideal for Air Conditioning Hotels Hospitals Schools Conference Rooms Theatres Office Blocks Apartments Airports Leisure Centres Shopping Malls Machinery rooms Technology s 230V ac. 120V ac. 1 (Refrigeration 1,000 ppm & Air Conditioning 10,000 ppm) 2 (volt free) 23 V dc. 1 Amp/120V ac. 1 Amp Optional (using controller) Semiconductor 1 only remote sensor/faceplate 1 (Optional) IAM-C Panel Call us today Tel: +353(1) Just some of the more common gases that our instruments detect... Carbon Dioxide (CO2); Refrigerant Gases such as R404a, R407c, R410a, R22, R507a, R134a, R290, R600, Ammonia (NH3); Hydrocarbons (HC); Methane/Natural Gas (CH4); Ethylene (C2H4); Sulphur Dioxide (SO2); Ozone (O3); Chlorine (Cl2); Chlorine Dioxide (ClO2); Carbon Monoxide (CO); Nitrogen Dioxide (NO2); Nitric Oxide (NO); Hydrogen (H2); Hydrogen Sulphide (H2S); Hydrogen Chloride (HCl); Liquefied Petroleum Gas (LPG); Oxygen (O2)

3 MGS-MURCO GAS SENSOR with 3 Optional s Standard IP66 Robust Continuous monitoring of most halocarbon refrigerants (HFC, HCFC, CFC), ammonia, hydrocarbons combustible, toxic and VOC gases s to meet almost any gas detection need at the most affordable cost electrochemical for low level monitoring; infrared for fast response; semiconductor for long life For customers who want to add to an existing system, the MGS can interface with any BMS or SCADA system. User-selectable linear analogue or digital outputs provide continuous monitoring and reporting: 4-20mA, 0-5V, 0-10V, 1-5V, 2-10V Optional stand-alone system using Murco controllers (1 to 16 channels) Robust design and remote sensor options allow sensors to be placed directly in areas where detection is needed Available in a variety of housings including IP66 and duct mount for placement in the toughest of environments Ideal for Commercial/Industrial Refrigeration Chiller & Plant Rooms Supermarkets Underground Car Parks Boiler & Machinery Rooms Food Ripening/Storage Processing Hospitals Schools Chemical Storage Rooms Greenhouses Water/Waste Treatment Technology s 12/24V dc./ac. 50/60Hz 1 (using controller) but also field programmable 1 (volt free) Optional (using controller) Semiconductor + Infrared + Electrochemical 7 (refer to back page) Optional (3) or can integrate into BMS MGS MODBUS with 3 Optional s Ideal for Maintenance Facilities Schools/Universities Hospitals Garages Boiler Rooms Chiller Plants Wineries Supermarkets Food/Beverage Processing MGS-IR-RS - MGS Infrared Refrigerant (with Modbus) Can detect Carbon Dioxide (CO2) and selected hydrocarbons and refrigerant gases MGS Modbus RS485 RTU interface offers easy integration and increased connectivity Versatility of Modbus offers software control alarm delay and set points User-Selectable linear analogue and digital outputs: 4-20mA, 0-5V, 0-10V, 1-5V, 2-10V On-board alarm LED and audible alarm Digital Output; 1 relay, 1 A, 24 VAC/DC Alarm Delay; User selectable; 0, 1, 5, 10 minutes 7 Optional housings and 3 optional controllers (refer back page) MGS-IR-RS Detects the most common halocarbon refrigerants R134a, R404a, R22, R407a, R407c, R507. The Infrared sensor allows for accurate, low level detection up to 1,000 ppm. This product is only available with the standard enclosure. ST-IAM SENSOR TRANSMITTER INTEGRATED AREA MONITOR with 3 Optional s Can detect the widest range of refrigerant, toxic, combustible and VOC gases to suit most applications Linear analogue, RS485 port and digital (relay) outputs for continuous monitoring and reporting (with ST-MON 350 transmitter) Easy plug in replacement sensors reduce yearly calibration and maintenance costs Ideal for multi sensor applications requiring a high degree of monitoring and reporting Stand-alone system combining sensor and monitor 2 volt-free relays connect to activate alarms/shut off valves Relays: 2 volt free contacts that can be manually or automatically reset 3 optional control panels allows for system expansion up to 65 sensors or connects directly to most BMS, SCADA or control systems Ideal for Industrial Refrigeration Chiller & Plant Rooms Underground Car Parks Boiler & Machinery Rooms Food Ripening/Storage/Processing Chemical Storage Rooms Greenhouses Water/Waste Treatment Technology s 12/24 V ac. 12/30 V d.c. 400mA maximum 2 (low and high) 2 (volt free) 24 V dc. Optional (using controller) Catalytic + Semiconductor + Infrared + Electrochemical 7 (refer to last page) Optional (3) or integrate into BMS

4 Aspirated Refrigerant Leak Detectors HGM-SZ Single Zone Monitor Single Zone gas leak refrigerant monitor Proprietary infrared sensor No calibration required Measurement range of 0-10,000 ppm sensitivity to 1 ppm Provides continuous unattended monitoring Capable of detecting and measuring any CFC, HFC, HCFC or NH3 Can monitor a location up to 150 metres from display unit Displays monitored gas as well as current and peak gas levels on LCD front panel Logs up to 200 previous gas readings for analysis Ideal for Mechanical Rooms Supermarkets Manufacturing Facilities Chiller Plants Measuring Range Gases Detected Output Signal 0-10,000 ppm (HGM-SZ). NH3 is 25-10,000 ppm (AGM-SZ) CFC, HFC, HCFC Refrigerant Gases (38 pre-programmed) NH3 (AGM-SZ) 3 SPDT 3 Amp, 250 VAC rated alarm relays and 1 SPDT 3 Amp 250 VAC rated system fault relay, plus a digital display with dedicated 4-20mA DC analogue output (floating ground) HGM-MZ Multi- Zone Monitor Halogen gas monitor detects HFC, CFC, HCFC, NH3 and C02 Lowest minimum detectable limit in the industry, 1 ppm Proprietary infrared sensor Expandable to support monitoring of up to 16 remote locations Optional remote display for centralised readings Each location can be up to 355 metres from centralized display unit No calibration required Fastest sampling rate with the longest sampling distance in the industry Large graphic LCD for easy set up and real time monitoring Ideal for Mechanical Rooms Supermarkets Physical Plants Refrigeration Racks Walk-in Freezers Measuring Range Gases Detected User Interface 0-10,000 ppm (HGM-MZ); 25-10,000 ppm (AGM-MZ); 0-8,000 ppm (CO2-MZ) CFC, HFC, HCFC Refrigerant Gases (38 pre-programmed) NH3, CO2 Front panel w/3 indicator lights: Green power on; Normal Yellow fault ; Yellow Flashing system fault; Red/Flashing point has exceeded alarm set PAGM Portable Area Gas Monitor Finds leaks as small as 1 ppm Portable gas detection for refrigerant gas HFC, CFC, HCFC s and C02 Stable, accurate non-dispersive IR (NDIR) technology Data storage up to 200 readings Can locate leaks in small and hard to reach areas Fast response and clearing times The LCD Display shows concentration in real time Visual and audible alarms for preset gas concentrations and ranges Logs up to 200 previous gas readings for analysis Ideal for Supermarket maintenance Measuring Range Gases Detected 0-10,000 ppm (refrigerant gases) in 1 ppm increments Refrigerants, CFC, HFC, HCFC, CO2

5 Optional Control Panels to provide stand-alone gas detection systems IAM MGS ST-IAM Standard s Temperature Rating *-20 C to +50 C IAM C Allows up to 16 sensors per panel which can be pyramided for system expansion MGD (IP41) 1 or 2 Channel 3 to 6 Channel 1 or 2 alarm levels 110VAC/ 220VAC operation 4-20 ma input Extra channels can be blanked off using a resister MGS (IP41) ST-MON 350 (Modbus) The ST-MON 350 is a combined data collection, monitoring and alarm system for small refrigeration installations User friendly LCD graphic screen records temperature readings Visual and audible alarms alert if thresholds are exceeded Alarms can be monitored off site as well as on site Stored data and graphs can be retrieved by connecting to a printer, PC or modem Eliminates false alarms as sensors can be individually programmed for one or more levels of alarm with individual delays Can connect with up to 16 MGS sensors using a direct signal 4-20 ma input Can connect with up to 65 ST-IAM sensors using data protocol. IAM (IP30) ST-IAM (IP41) Optional s MGD MGS ST-IAM Temperature Rating *-40 to + 50 C IP66 (optional splashguard) IP66 with Remote head IP66 with Pressure Relief Valve A very robust enclosure for high levels of dust moisture or where condensation is present. In heavy spray or wash down areas a splashguard can be added. Similar to the IP66, but for remote areas which are difficult to access, out of eye-line or compressure enclosures. (M42 thread fitting on remote head). To monitor blow off or weeping from pressure relief valves. Normally teed off vent pipe line to exterior. IP66 with Exd Rated Remote Head IP66 Airflow Duct Mount Exd Exd To monitor hazardous areas where ATEX rating is required such as areas with flammable gases. A more cost effective sensor to the full Exd model. The enclosure is placed outside the ATEX area with the remote sensor fitted inside the area. Certified to ATEX Exd 11C T5, Zone 1, Zone 2 ( Element only). To monitor refrigerant leaks in air conditioning systems or any gas in an airflow or ducts while allowing easy access to the sensor for maintenance. It is mounted on the outside of the duct and a pitot sample tube extends into the duct. The airflow goes in one leg of the pitot up into the sensor enclosure where the sensor head lies and back out into the duct. To monitor hazardous areas where flammable gases, vapour fumes or dust are present. The enclosure is approved for Zone 1 and Zone 2. It is flame proof, explosion proof, and weather proof (ATEX, Ex d IIB+H2 T6 IP66). Designed with individually certified EXD main housing enclosure and certified Exd sensor enclosures. The final Exd Gas Monitor assemblies (main enclosure and sensor assembly) have not been certified as a complete unit. *Exceptions: Electrochemical detect from -20 C to +40 C. s can detect as low as -40 C up to 40 C for ammonia (NH3) 0-2,000 ppm only

6 Fixed Gas Detection Target Markets, Products, Hazards and Applications Market Products Gas Hazards Commercial Refrigeration Industrial Refrigeration Commercial Gas Detection Light Industrial / Industrial MGD IAM MGS MGS Modbus ST-IAM HGM-MZ/SZ Ammonia (NH3) Carbon Dioxide (CO2) Carbon Monoxide (CO) Combustible Gases (hydrocarbons) Formaldehyde (HCHO) Hydrogen - Combustible Gas Ethylene (C2H4) Hydrogen Sulfide (H2S) Oxygen (O2) Nitrogen Dioxide (NO2) Refrigerants Sulfur Dioxide (SO2) Chlorine Dioxide (ClO2) Chlorine (Cl2) Ozone (O3) Volatile Organic Compounds (VOC) Applications Airports Bakery Battery Charging Rooms Boiler/Machinery Rooms Brewing Chemical Storage Rooms Chiller Rooms Conference Rooms Convenient Stores Dormitories Fishing Vessels Food Distribution Centres Food Processing Fruit Ripening Greenhouses Hockey Arenas Hospitals Hotels Ice Making Plants Indoor Air Quality Laboratories Leisure Centres Loading Docks/Bays Meat Processing Plants Office Blocks Pharmecuetical Power Generation Poultry Farms Pulp and Paper Pumping Stations Shopping Malls Steel and Metal Production Supermarkets Operating Theatres Underground Car Parks Universities Vehicle Repair Shops Water / Waste Water Wineries Murco Limited, (A Bacharach Company) 114a George s St. Lower, Dun Laoghaire, Co. Dublin Tel: Fax: sales@murco.ie Web: QUALITY I.S. EN ISO 9001:2008 NSAI Certified HEALTH & SAFETY LEGAL COMPLIANCE EFFECTIVE COST

CH 4 C 2 H 2 C 3 H 8 CO 2 H 2 H 2 S HFC NH 3 NO 2 O 2 O 3 SO 2

CH 4 C 2 H 2 C 3 H 8 CO 2 H 2 H 2 S HFC NH 3 NO 2 O 2 O 3 SO 2 PluraSens CH 4 C 2 H 2 C 3 H 8 CO CO 2 H 2 H 2 S HFC NH 3 NO 2 O 2 O 3 SO 2 VOC E2600 Family Gas Detectors E2610 Series Compact wall-mount housing providing optimal airflow Integrated sensor with long

More information

IGD.CO.UK

IGD.CO.UK APPLICATION DATA SHEET S p e c i f i c a t i o n 2 SO22 WWW.-..UK Control Systems Transmitters Sensors Accessories TOCSIN 700+ D e t e c t o r Website: C o n t r o l P a n e l - Wall mounting or 19 Rack

More information

Two-Channel Gas Controller

Two-Channel Gas Controller Two-Channel Gas Controller Specifications subject to change without notice. USA 09 Page of DESCRIPTION Highly configurable, UL 0 performance-tested and -certified, and wall-mounted gas monitor; continuously

More information

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6 Digital Gas Transmitters with Auxiliary s & Control Specifications subject to change without notice. USA 181011 Page 1 of 5 DESCRIPTION Digital RS-485 communicating, addressable toxic and combustible gas

More information

Sieger Apex. Flexibility that meets your requirements

Sieger Apex. Flexibility that meets your requirements Sieger Apex Flexibility that meets your requirements Sieger Apex Easy to Install Sensor can be remotely mounted up to 100m from the transmitter On board relays allow for local audible/ visual alarms Strong

More information

incontrol Systems Inc. Flame and Gas Detection

incontrol Systems Inc. Flame and Gas Detection incontrol Systems Inc. Flame and Gas Detection Our flame and gas detectors are globally certified to the latest product approval standards Wherever toxic or combustible gases are part of an industrial

More information

VASTHI ENGINEERS. Vasthi Multi Gas Monitor/Analyzer. Sheet No. 1 of 4. Vasthi Multi Gas monitor/analyzer with alarm and Graphical Display.

VASTHI ENGINEERS. Vasthi Multi Gas Monitor/Analyzer. Sheet No. 1 of 4. Vasthi Multi Gas monitor/analyzer with alarm and Graphical Display. Sheet No. 1 of 4 monitor/analyzer with alarm and Graphical Display. Sheet No. 2 of 4 It specially designed to analyze any gas of your choice, its automatic operation, accurate measurement and crystal clear

More information

Quality. Water. Water Quality. Testing. Testing. Toxic Gas Detection. Toxic Gas. Detection. Air Quality. Monitoring. Monitoring. Monitoring.

Quality. Water. Water Quality. Testing. Testing. Toxic Gas Detection. Toxic Gas. Detection. Air Quality. Monitoring. Monitoring. Monitoring. Water Quality Labo- Soil/ Soil/ Sedi- Sam- & Air / Dust Toxic gases are present in a wide variety of industrial and civil installations and their detection and monitoring is crucial for the safe working

More information

Self-contained and intrinsically safe wireless stand-alone multi-point gas detector.

Self-contained and intrinsically safe wireless stand-alone multi-point gas detector. Introduction United Safety applies the detection system as a multi-point monitoring for toxic gases, combustibles and oxygen hazards. Self-powered and solar-capable, the features unequaled versatility,

More information

SIL 2. Ultima X Series Gas Monitors CERTIFIED

SIL 2. Ultima X Series Gas Monitors CERTIFIED Ultima X Series Gas Monitors 5 Now with SIL 2 CERTIFIED Products Versatile fixed instruments provide continuous monitoring of many hazardous gases using catalytic, electrochemical, and infrared gas detection

More information

Recalibrate the way you look at gas detection

Recalibrate the way you look at gas detection Catalogue Gas detection solution Recalibrate the way you look at gas detection Next generation gas detection for industrial refrigeration The next generation of Danfoss gas detectors are based on a digital

More information

compact detector Detection of more than 200 flammable and toxic gases iso 9001:2008

compact detector Detection of more than 200 flammable and toxic gases iso 9001:2008 iso 9001:2008 Quality Management Systems Systéme de Qualité www.sgs.com possibility of additional functions detection of critical temperature detection of flooding electrochemical sensor catalytic sensor

More information

PolyGard Single Point Controller SPC-X3-11XX for Toxic Gases and Oxygen

PolyGard Single Point Controller SPC-X3-11XX for Toxic Gases and Oxygen PolyGard Single Point Controller SPC-X3-XX for Toxic Gases and Oxygen DESCRIPTION Gas measuring, monitoring and warning controller based on state-of-the-art micro-technology with integrated sensor and

More information

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots 5 Operating Modes GX-6000 Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots CONFINED SPACE ENTRY Monitor LEL, O2, CO, and H2S Internal sample pump Pull samples

More information

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors Ultima X Series Gas Monitors Versatile fixed instruments provide continuous monitoring of many hazardous gases using catalytic, electrochemical, and infrared gas detection methods. HART Protocol is now

More information

Intelligent combined sensor for Air Quality (VOC) + Humidity (rh) + Temperature (T) with analogue outputs, Modbus and LCD display. Features.

Intelligent combined sensor for Air Quality (VOC) + Humidity (rh) + Temperature (T) with analogue outputs, Modbus and LCD display. Features. Features To measure and take control of indoor air quality Three noses in same unit Air Quality (VOC), Humidity (rh) and Temperature (T) Selectable outputs 0-10 Vdc, 4-20 ma or 0-5 Vdc via jumpers on pcb

More information

OLC(T) 100 FIXED GAS DETECTOR

OLC(T) 100 FIXED GAS DETECTOR Fixed Gas Detector OLC(T) FIXED GAS DETECTOR Detection of explosive gases, toxic gases or oxygen Infrared XP version SIL 2 high reliability IP 66 Aluminium or Stainless Steel version CERTIFICATIONS The

More information

Toxic Gas Detection. Model F12. Toxic Gas Detection

Toxic Gas Detection. Model F12. Toxic Gas Detection Toxic Gas Detection Model F12 Toxic Gas Detection Smart Sensor Technology The Series F12 Gas Transmitter is an Intrinsically Safe (IS) version of our explosion-proof D12 transmitter. In its standard form,

More information

ST-IAM Sensor Transmitter Integrated Area Monitor. Check / Calibration Procedure* 10 ASH (1)

ST-IAM Sensor Transmitter Integrated Area Monitor. Check / Calibration Procedure* 10 ASH (1) ST-IAM Sensor Transmitter Integrated Area Monitor Check / Calibration Procedure* Content Page 1-Introduction 2 2-Bump Test 2 3-Calibration 3 a. Exchanging sensor board 3 b. Gas Calibration 3 4-Additional

More information

EAGLE 2. 6 Channel Capacity. Inlet fitting. Loud buzzer (95dB) IrDA communication port Low flow shutoff and alarm Alarm LED s with wide visibility

EAGLE 2. 6 Channel Capacity. Inlet fitting. Loud buzzer (95dB) IrDA communication port Low flow shutoff and alarm Alarm LED s with wide visibility EAGLE 2 Inlet fitting Loud buzzer (95dB) IrDA communication port Low flow shutoff and alarm Alarm LED s with wide visibility Internal / external hydrophobic filters Self healing polyurethane protective

More information

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots 5 Operating Modes GX-6000 Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots GX-6000 5 Operating modes Normal Leak Check Inert Bar hole Snap Log Monitor up to

More information

3M Oldham OLCT 100. Description. Fixed Gas Detector

3M Oldham OLCT 100. Description. Fixed Gas Detector Fixed Gas Detector Description The OLC/OLCT range of fixed detectors has been designed for detection of combustible gases, toxic gases or oxygen. Available in explosion-proof or intrinsically safe versions,

More information

Model D12. Digital Gas Transmitter

Model D12. Digital Gas Transmitter Model D12 Digital Gas Transmitter Gas detection systems come in all shapes and sizes. Some require simple 4-20 ma transmission. Some are better suited to local alarm relay functions. Some really require

More information

Gas Detection Sensor type GDA, GDC, GDHC, GDHF, GDH REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Gas Detection Sensor type GDA, GDC, GDHC, GDHF, GDH REFRIGERATION AND AIR CONDITIONING. Technical leaflet Gas Detection Sensor type GDA, GDC, GDHC, GDHF, GDH REFRIGERATION AND AIR CONDITIONING Technical leaflet Contents Page Introduction... 3 Features... 3 Technical data... 3 Electrical connection... 4 Design...

More information

Gas detecting sensor Types GDA, GDC, GDHC, GDHF, GDH

Gas detecting sensor Types GDA, GDC, GDHC, GDHF, GDH Data sheet Gas detecting sensor Types GDA, GDC, GDHC, GDHF, GDH Danfoss gas detecting sensor program, type GD is a range of products designed to meet all industrial refrigeration and air conditioning applications.

More information

Carbon Monoxide (CO) Gas Detectors with (0)2-10 Vdc or (0)4-20 ma Output

Carbon Monoxide (CO) Gas Detectors with (0)2-10 Vdc or (0)4-20 ma Output Features Electrochemical sensor element (0)2-10 Vdc or (0)4-20 ma output, jumper selectable Standard IP65 plastic enclosure Measuring ranges 0-50 ppm 0-100 ppm 0-150 ppm 0-200 ppm 0-250 ppm 0-300 ppm 0-500

More information

OLCT 100 DETECTION DE GAZ FIXE. Certifications. Better detection. Better protection. Detection of Combustible, Toxic or Oxygen gases

OLCT 100 DETECTION DE GAZ FIXE. Certifications. Better detection. Better protection. Detection of Combustible, Toxic or Oxygen gases DETECTION DE GAZ FIXE OLCT Detection of Combustible, Toxic or Oxygen gases Infrared XP version SIL 2 high reliability IP 66 Aluminium or Stainless Steel version Certifications Better detection. Better

More information

ULTIMA XL/XT Series Gas Monitors. [ Ultimate Features Extreme Design ]

ULTIMA XL/XT Series Gas Monitors. [ Ultimate Features Extreme Design ] ULTIMA XL/XT Series Gas Monitors [ Ultimate Features Extreme Design ] Cost effective fixed installation gas monitors with HART Field Communications Protocol. Single-sensor units use catalytic, electrochemical

More information

MultiRAE Lite. Wireless Portable Multi-Gas Monitor

MultiRAE Lite. Wireless Portable Multi-Gas Monitor MultiRAE Lite Wireless Portable Multi-Gas Monitor The MultiRAE Lite is an optimal one-to-six 4 -gas monitoring solution for personal protection (including confined space entry) and multi-gas leak detection

More information

WARRANT Y AND LIMITS OF LIABILIT Y Vulcain Inc. warrants to the original purchaser that its product, and the component parts thereof, will be free fro

WARRANT Y AND LIMITS OF LIABILIT Y Vulcain Inc. warrants to the original purchaser that its product, and the component parts thereof, will be free fro A d e v i h c r D c o n e m u WARRANT Y AND LIMITS OF LIABILIT Y Vulcain Inc. warrants to the original purchaser that its product, and the component parts thereof, will be free from defects in workmanship

More information

MGS Murco Gas Sensor EC / SC model Gas Detector and Transmitter. Installation & Operation* 08 ASH (1)

MGS Murco Gas Sensor EC / SC model Gas Detector and Transmitter. Installation & Operation* 08 ASH (1) MGS Murco Gas Sensor EC / SC model Gas etector and Transmitter Installation & Operation* Content Page - Installation Instructions - Location Instructions - Typical Settings - Installation and Wiring iagrams

More information

Leak detector for refrigerant gases R22, R134a, R410A, R407C...

Leak detector for refrigerant gases R22, R134a, R410A, R407C... PCE-GA3 PCE-LD 1 PCE-GA 70 Pen-sized flammable gas detector Leak detector for refrigerant gases R22, R134a, R410A, R407C... CO2 detector with data logger and software This pen-sized flammable gas detector

More information

GAS DETECTION International Gas Detectors CH4 NO

GAS DETECTION International Gas Detectors CH4 NO GAS DETECTION HSCO SOCO GAS DETECTORS FOR INDUSTRIAL ENVIRONMENTS TOCSIN 150 SERIES ADDRESSABLE GAS SAMPLERS Quality Assured HSCO SOCO In many applications in industry requiring gas detection it is often

More information

Refrigerant Leak Detection Solutions

Refrigerant Leak Detection Solutions Refrigerant Leak Detection Solutions Gas Leak Detection Overview There are different environmental reasons why gas leak detection is needed and an endless list of benefits for you, the customer, for having

More information

SPECIFICATION MODEL 5200 GAS MONITOR SYSTEM. User Instructions For The Model 5200 Gas Monitor System

SPECIFICATION MODEL 5200 GAS MONITOR SYSTEM. User Instructions For The Model 5200 Gas Monitor System SPECIFICATION MODEL 5200 GAS MONITOR SYSTEM User Instructions For The Model 5200 Gas Monitor System To completely customize the specifications to your exact application, modifications to the following

More information

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Certifications. The Fixed Gas Detection People

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Certifications. The Fixed Gas Detection People Fixed Gas Detector Detection of explosive gases, toxic gases or oxygen Infrared XP version SIL 2 high reliability IP 66 Certifications The Fixed Gas Detection People The OLC/OLCT CT range of fixed ddetectors

More information

Industrial Grade Gas Detection Detecting The Difference

Industrial Grade Gas Detection Detecting The Difference detcon inc. Industrial Grade Gas Detection Detecting The Difference PO Box 8067 The Woodlands, TX 77387 888-367-4286 (toll free) 713-559-9200 281-292-2860 (fax) sales@detcon.com Catalog #CB-0409 www.detcon.com

More information

Fixed Gas & Flame Detection International Product Range Overview

Fixed Gas & Flame Detection International Product Range Overview Fixed Gas & Flame Detection International Product Range Overview Over 100 years of experience and capability in comprehensive safety solutions have made MSA a modern and forward-looking company for the

More information

4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head

4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head 4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head NET DRAFT version 2.1-2008 Pag. 1 4-20mA Cyber - DRAFT version 2.1-2008 Pag.

More information

Danfoss gas detection units

Danfoss gas detection units Data sheet Danfoss gas detection units Types GD Premium, Premium+, Premium Duplex, Premium Remote, Premium Flex and Premium Uptime The Premium line gas detection units are used for monitoring and warning

More information

Gas Detection. - Disposable - Serviceable. Single Gas Detectors

Gas Detection. - Disposable - Serviceable. Single Gas Detectors Gas Detection Single Gas Detectors Introduction Portable single gas detectors are used for personal protection and have the ability to detect a single gas hazard. Typically they are small, lightweight

More information

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required Sieger Sensepoint The Sensepoint range of flammable, toxic and oxygen gas detectors offer users a high quality, low cost solution to their industrial gas monitoring needs. Sieger Sensepoint Fit For Purpose

More information

portable gas analyser

portable gas analyser www..com portable gas analyser The largest of s analysers equipped with electrochemical cells. It can fit even up to 7 EC cells and up to 3 sensors. GA-60 has a large (320*240), graphical LCD with backlighting.

More information

Monitores Personales. Personal Monitor

Monitores Personales. Personal Monitor Monitores Personales Personal Monitor Micro IV Full Featured Personal Monitor Micro IV Single-gas Detector Highly configurable smart sensor design Wide range of sensors including O 2, H 2 S, CO, NH 3,

More information

Warranty Registration

Warranty Registration WARRANT Y AND LIMITS OF LIABILIT Y Vulcain Inc. warrants to the original purchaser that its product, and the component parts thereof, will be free from defects in workmanship and materials for a period

More information

3years. Detection of explosive gases, toxic gases and oxygen. Infrared XP IR version. SIL 2 high reliability IP 66.

3years. Detection of explosive gases, toxic gases and oxygen. Infrared XP IR version. SIL 2 high reliability IP 66. Fixed Gas Monitoring Solutions Detection of explosive gases, toxic gases and oxygen Infrared XP IR version SIL 2 high reliability IP 66 E n o r t c e l i c 3years W a r r a t n y Certifications: The Fixed

More information

Fixed Range. Fixed Gas Detection Equipment. Field mounted gas detection. solutions for the protection of. plant and personnel

Fixed Range. Fixed Gas Detection Equipment. Field mounted gas detection. solutions for the protection of. plant and personnel Fixed Range Fixed Gas Detection Equipment Field mounted gas detection solutions for the protection of plant and personnel Fixed Range The Crowcon Fixed Gas Detector Range When lives and property are at

More information

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Aluminium or Stainless Steel version

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Aluminium or Stainless Steel version Fixed Gas Detector Detection of explosive gases, toxic gases or oxygen Infrared XP version SIL 2 high reliability IP 66 Aluminium or Stainless Steel version Certifications Pending The Fixed Gas Detection

More information

Danfoss gas detection unit Type GD Heavy Duty

Danfoss gas detection unit Type GD Heavy Duty Data sheet Danfoss gas detection unit Type GD Heavy Duty The Heavy Duty gas detection units are used for monitoring and warning of hazardous Ammonia gas concentrations. They are intended for ATEX/ IECEx

More information

Frequently Asked Questions

Frequently Asked Questions 1. 2. What advantages does the GT3000 have over the C7064? Hot swappable GTS sensor module is intrinsically safe and allows live maintenance under power Supports HART communication Supports local, one-person

More information

MGD - Murco Gas detector / Monitor. Installation & Operation* 08 ASH (1)

MGD - Murco Gas detector / Monitor. Installation & Operation* 08 ASH (1) MGD - Murco Gas detector / Monitor Installation & Operation* Content Page - Installation Instructions - Location Instructions - Typical Settings - Operating Instructions 5- Test/Function Instructions 6-

More information

G-TECTA TM. Portable Gas Detection Instruments

G-TECTA TM. Portable Gas Detection Instruments G-TECTA TM Portable Gas Detection Instruments 2 Why Linde gas detection? The Linde Group is a global leader in the supply of gases, we provide expertise and product solutions to industry, commerce, science

More information

EXAMPLES OF HOW TO ORDER

EXAMPLES OF HOW TO ORDER E 3 Point PRODUCT SUBMITTAL Toxic and Combustible Gas Detector Standalone Platform (Single or Dual-Gas Monitoring) ORDERING INFORMATION Single-Gas or Dual-Gas Configuration: Base Unit, Surface-Mount Base

More information

APPLICATION DATA SHEET

APPLICATION DATA SHEET APPLICATION DATA SHEET S p e c i f i c a t i o n WWW.-..UK Control Systems Transmitters Sensors Accessories TOCSIN 700 D e t e c t o r C o n t r o l P a n e l Wall mounting 24V DC or 110/230vAC operation

More information

EXAMPLES OF HOW TO ORDER

EXAMPLES OF HOW TO ORDER E 3 Point PRODUCT SUBMITTAL Toxic and Combustible Gas Detector Standalone Platform (Single or Dual-Gas Monitoring) ORDERING INFORMATION Single-Gas or Dual-Gas Configuration: Base Unit, Surface-Mount Base

More information

REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS WITH LOCAL DIGITAL DISPLAY

REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS WITH LOCAL DIGITAL DISPLAY REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS WITH LOCAL DIGITAL DISPLAY FEATURES TXGARD & FLAMGARD PLUS Digital display with flexible output options Wide range of long life sensors Non-intrusive one-man

More information

P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification

P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification 1.0 This specification details the attributes and operating characteristics of the MSA Ultima X Series sensors/transmitters.

More information

Danfoss gas detection units

Danfoss gas detection units Data sheet Danfoss gas detection units Types GD Premium, Premium+, Premium Duplex, Premium Remote, Premium Flex and Premium Uptime The Premium line gas detection units are used for monitoring and warning

More information

APPLICATION DATA SHEET

APPLICATION DATA SHEET APPLICATION DATA SHEET Control Systems Transmitters Sensors Accessories Wall, 19 Rack or Panel Mounting Units 110/230V 50/60Hz AC operation 250 Addressable devices as: Relays, 4-20 Inputs or Gas Detectors

More information

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required Sieger Sensepoint The Sensepoint range of flammable, toxic and oxygen gas detectors offer users a high quality, low cost solution to their industrial gas monitoring needs. Sieger Sensepoint Fit For Purpose

More information

ALTAIR 5X Multigas Detector Product Specification

ALTAIR 5X Multigas Detector Product Specification ALTAIR 5X Multigas Detector Product Specification PHYSICAL CHARACTERISTICS Gas delivery Size, pumped unit without IR Size, pumped unit with IR Weight Handling Case material Environmental protection Display

More information

PolyGard Single Point Controller SPC-X3-20XX for refrigerant gases and vapours

PolyGard Single Point Controller SPC-X3-20XX for refrigerant gases and vapours PolyGard Single Point Controller SPC-X3-20XX for refrigerant gases and vapours DESCRIPTION Gas measuring, monitoring and warning controller based on state-of-the-art micro-technology with integrated sensor

More information

Model D12-IR. Digital Gas Transmitter...

Model D12-IR. Digital Gas Transmitter... Model D12-IR Digital Gas Transmitter... ATI s Series D12 gas transmitter line now includes a versatile Infrared system that can be configured for LEL or select toxic gases. The D12-IR utilizes a compact

More information

APPLICATION DATA SHEET

APPLICATION DATA SHEET APPLICATION DATA SHEET Wed : www.saenchotesei.com WWW.-..UK Control Systems Transmitters Sensors Accessories TOCSIN 920 - Wall, 19 Rack or Panel Mounting Units - 110/230V 50/60Hz AC operation - 250 Addressable

More information

Detectors-Transmitters for Flammable, Toxic Gases and Oxygen. Non-intrusive operation via intrinsically safe infrared remote control.

Detectors-Transmitters for Flammable, Toxic Gases and Oxygen. Non-intrusive operation via intrinsically safe infrared remote control. Détecteur de gaz OLCT80 Detectors-Transmitters for Flammable, Toxic Gases and Oxygen Non-intrusive operation via intrinsically safe infrared remote control Disponible en version déportée, ADF ou de SI

More information

T.ex Single Gas Detector VISA

T.ex Single Gas Detector VISA T.ex Single Gas Detector The T.ex is newest instrument in the Promat portfolio. The instrument is currently available in Oxygen, Hydrogen Sulphide and Carbon Monoxide versions. A Bump Test Station is available

More information

MGS-350 Gas Detector Installation and Operation Manual Instruction Revision 1 February 2013 Product Leadership Training Service

MGS-350 Gas Detector Installation and Operation Manual Instruction Revision 1 February 2013 Product Leadership Training Service MGS-350 Gas Detector Installation and Operation Manual Instruction 6509-9000 Revision 1 February 2013 Product Leadership Training Service Reliability WARRANTY POLICY BACHARACH, INC. WARRANTS THIS INSTRUMENT,

More information

Product Selection Guide Fixed Gas Detection Systems for Personnel & Equipment Safety

Product Selection Guide Fixed Gas Detection Systems for Personnel & Equipment Safety Product Selection Guide Fixed Gas Detection Systems for Personnel & Equipment Safety GDS Corp gas monitors, controllers and sensors satisfy today s needs for safety and reliability in critical gas detection

More information

Personal & Portable Gas Monitors

Personal & Portable Gas Monitors Eikon Personal & Portable Gas Monitors Eikon is a life personal alarm providing two years of maintenance free continuous monitoring. Tough and rugged, Eikon TM is dust and water tight to IP65. Intrinsically

More information

REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS

REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS FEATURES Extremely wide range of sensors Easy installation and maintenance Low cost of ownership Replacement of sensors are simple Rugged and reliable

More information

Electrochemical DrägerSensor Sensors for Fixed Gas Detectors

Electrochemical DrägerSensor Sensors for Fixed Gas Detectors Electrochemical DrägerSensor Sensors for Fixed Gas Detectors Fast response, high accuracy, great stability, long life. Electrochemical DrägerSensors offer all these benefits. You can use the robust and

More information

SP-220. Features. Combustible handheld gas leakage detector

SP-220. Features. Combustible handheld gas leakage detector SP-220 Combustible handheld gas leakage detector The SP-220 gas leakage detector is a simple to operate unit with high sensitivity to a variety of gases. The SC version (SP-220SC) is able to detect super-toxic,

More information

YOUR PARTNER IN FIRE & GAS DETECTION

YOUR PARTNER IN FIRE & GAS DETECTION YOUR PARTNER IN FIRE & GAS DETECTION OGGIONI s.a.s. Via Lavoratori Autobianchi, 1 - P.T.B. Edif.13/O - 20832 Desio (MB) Italy Tel.+39 0362 629135 Fax. +39 0362 622531 www.oggionisas.com - info@oggionisas.com

More information

Sensepoint. Fit For Purpose Flammable, toxic and oxygen versions available High performance, low cost Suitable for new and retro fit applications

Sensepoint. Fit For Purpose Flammable, toxic and oxygen versions available High performance, low cost Suitable for new and retro fit applications Sensepoint The Sensepoint range of flammable, toxic and oxygen gas detectors offer users a high quality, low cost solution to their industrial gas monitoring needs. Sensepoint Fit For Purpose Flammable,

More information

Xgard. Fixed detectors For flammable, toxic or oxygen gases

Xgard. Fixed detectors For flammable, toxic or oxygen gases Fixed detectors For flammable, toxic or oxygen gases Xgard Xgard Type 1: Xgard Type 2: Xgard Type 3: Xgard Type 4: Xgard Type 5: Xgard Type 6: Xsafe: Intrinsically safe toxic and oxygen gas detector Flameproof

More information

P R O D U C T D ATA S H E E T

P R O D U C T D ATA S H E E T Keyless RFID Control PGF- Effective Gas Safety Proving and Gas Detection Controller RFID Gas Proving, Ventilation Control & Gas Detection, off one panel Our range of gas proving systems can be used for:

More information

Dräger Polytron 8310 IR Detection of flammable gases and vapour

Dräger Polytron 8310 IR Detection of flammable gases and vapour Dräger Polytron 8310 IR Detection of flammable gases and vapour The Dräger Polytron 8310 IR is an advanced explosion proof transmitter for the detection of combustible gases in the lower explosion limit

More information

PRODUCT CATALOGUE. Gas & Air Quality Detectors Controllers Transmitters

PRODUCT CATALOGUE. Gas & Air Quality Detectors Controllers Transmitters PRODUCT CATALOGUE Gas & Air Quality Detectors Controllers Transmitters Engineered gas and environmental monitoring solutions for industry. Austech is a full lifecycle solution provider of gas, flame and

More information

MGD Murco Gas Detector. Check / Calibration Procedure* 10 ASH (1)

MGD Murco Gas Detector. Check / Calibration Procedure* 10 ASH (1) MGD Murco Gas Detector Check / Calibration Procedure* Content Page 1- Introduction 2 2- Electrical Set-Up 2 3- Bump Test 2 4- Calibration 3 4.1 Exchange Sensor board 3 4.2 Gas Calibration 3 5- Additional

More information

GAS DETECTION MANUFACTURED BY. Aerionics, Inc. Sioux Falls, SD Phone:

GAS DETECTION MANUFACTURED BY. Aerionics, Inc. Sioux Falls, SD Phone: CM-1 CO ppm MANUFACTURED BY Aerionics, Inc. Sioux Falls, SD Phone: 1-877-367-7891 Email: info@aerionicsinc.com www.macurco.com Detectors for use with Fire and Security Systems The Macurco CM-E1, GD-2B,

More information

P R O D U C T D ATA S H E E T

P R O D U C T D ATA S H E E T PGF- Effective Gas Safety Proving and Gas Detection Controller Gas Pressure Proving For use with Natural Gas LPG - or Laboratory gas supplies, both high and low pressure ensuring system integrity prior

More information

P R O D U C T D ATA S H E E T

P R O D U C T D ATA S H E E T TOCSIN 750 SERIES ANNUNCIATORS Addressable Gas Detection Interface Point -Wire Addressable Systems Sounder Display Shows: Reading-Message-Alarm RGB Relay Output off Solid State Beacon Sounder Output off

More information

Confined Space Monitoring. Leak Investigation. Functions 4. Bar Hole Sampling. Line Purge Testing. Actual Size GX-2012

Confined Space Monitoring. Leak Investigation. Functions 4. Bar Hole Sampling. Line Purge Testing. Actual Size GX-2012 Confined Space Monitoring Leak Investigation 1 Functions 4 Bar Hole Sampling Line Purge Testing Actual Size GX-2012 3 Operating Modes Internal sample draw pump with 50 range Low flow alarm 3 bright visual

More information

portable gas analyser

portable gas analyser www..com portable gas analyser Professional flue gas analyser that combines high quality of sample conditioning with great measurement accuracy. The device is contained in a compact soft casing. Analyser

More information

AT-G-SENSE Gas Sensing System

AT-G-SENSE Gas Sensing System AT-G-SENSE Gas Sensing System INSTALLATION & OPERATING MANUAL INSTALLATION INSTRUCTIONS Open the AT-G-SENSE by undoing the two screws. Remove metal faceplate, turn over and check connection terminals (maximum

More information

GAS DETECTOR ST400EC PART.NO

GAS DETECTOR ST400EC PART.NO DATA SHEET 1(7) GAS DETECTOR ST400EC PART.NO. 004461-004467 DETECTION OF TOXIC GASES AND OXYGEN SYSTEM GS5000, GS3000, SW2020, BUCONTROL / BUTOUCH GENERAL DESCRIPTION Detection of toxic gases and Oxygen

More information

INSTALLATION AND OPERATING INSTRUCTIONS

INSTALLATION AND OPERATING INSTRUCTIONS INSTALLATI AND OPERATING INSTRUCTIS PRODUCTS CMD Series CO Detectors FGD Series Refrigerant Detectors AGD Series Toxic Gas Detectors CGD Series Combustible Gas Detectors (All transmitters are factory set

More information

OLCT 700 & 710. Certifications FIXED GAS DETECTION. Better detection. Better protection.

OLCT 700 & 710. Certifications FIXED GAS DETECTION. Better detection. Better protection. FIXED GAS DETECTION OLCT 700 Series OLCT 700/710 industrial gas detection sensors are a new generation of intelligent sensor modules that incorporate and integrate several leading edge improvements. &

More information

Dräger Polytron 5700 IR Detection of flammable gases and vapours

Dräger Polytron 5700 IR Detection of flammable gases and vapours Dräger Polytron 5700 IR Detection of flammable gases and vapours The Dräger Polytron 5700 IR is a cost effective explosion-proof transmitter for the detection of flammable gases in the lower explosive

More information

Installation & Operation

Installation & Operation Integrated Area Monitor IAM Integrated Area Monitor Control Panel IAM-C Installation & Operation Content Page 1- IAM Sensor -Installation Instructions 2 2- IAM Sensor -Location Instructions 2 3- IAM Sensor

More information

Global Gas Detection and Monitoring Solutions

Global Gas Detection and Monitoring Solutions Global Gas Detection and Monitoring Solutions With over 100 years experience in specialized safety, fire and gas detection systems, we are The Fixed Gas Detection Experts. www.oldhamgas.com At Oldham,

More information

AquiTron DATA S HEET. AT-GU Commercial Refrigerant Sensor

AquiTron DATA S HEET. AT-GU Commercial Refrigerant Sensor AquiTron DATA S HEET Commercial Refrigerant Sensor CONTENTS 1.0 Overview 1.1 General Information 1.2 Technical Specifications 2.0 Front Panel Layout 2.1 General Placement Guidelines 2.2 Components and

More information

Carbon Monoxide CO Transmitter ADT-X3-1110

Carbon Monoxide CO Transmitter ADT-X3-1110 Page 1 Sep. 2017 CO transmitter including digital measurement value processing and temperature compensation for the continuous monitoring of the ambient air to detect carbon monoxide concentrations (CO).

More information

Gas Central with built-in Gas Detector for Nitrogen Dioxide (NO 2

Gas Central with built-in Gas Detector for Nitrogen Dioxide (NO 2 Features Integrated (built-in NO2 sensor / detector (Electro chemical sensor type Measuring ranges 0-10 ppm, 0-20 ppm or 0-30 ppm LCD display to show actual in ppm Status LED indication Normal operation

More information

GasSens. Self Checking Gas Sensors. Modular Gas Detector... Gas & Range Availability

GasSens. Self Checking Gas Sensors. Modular Gas Detector... Gas & Range Availability GasSens Modular Gas Detector... Self Checking Gas Sensors GasSens is a flexible component system providing a variety of options to meet individual gas detection and alarm requirements. From chemical and

More information

Industrial Grade Gas Detection

Industrial Grade Gas Detection Industrial Grade Gas Detection DETECTING THE... Difference Catalog #CB 0112 detcon inc. an company www.detcon.com Houston Odessa Shanghai Dammam Del Carmen Europe Company Profile ISO 9001: 2008 Certified

More information

Fixed Gas Detection Equipment

Fixed Gas Detection Equipment CO 2 CI 2 NH 3 O 3 CO Fixed Gas Detection Equipment O 2 CH 4 O 2 CO 2 Field mounted gas detection solutions for the protection of plant and personnel D e t e c t o r s Xgard Detectors for Oxygen, Flammable

More information

M2A Transmitter Operator s Manual

M2A Transmitter Operator s Manual M2A Transmitter Operator s Manual Part Number: 71-0305RK Revision: F Released: 1/8/18 RKI Instruments, Inc. www.rkiinstruments.com WARNING Read and understand this instruction manual before operating instrument.

More information

Danfoss Gas Sensor DGS MODBUS

Danfoss Gas Sensor DGS MODBUS Installation Guide Danfoss Gas Sensor DGS MODBUS ADAP-KOOL Refrigeration Control System DGS - Location instructions Location of Sensors Sensors must be located within the appropriate wire lengths from

More information

SUPREMATouch. Modular Fire & Gas Detection System

SUPREMATouch. Modular Fire & Gas Detection System SUPREMATouch Modular Fire & Gas Detection System Tel: +44 (0)8 9388 Email: info@ Fire & Gas Detection Solutions MSA permanent gas detection systems are used throughout the world to protect plant and personnel

More information