2012 B.C. Building Code Compliance Review (Division B Part 3)
|
|
- Rhoda Joseph
- 5 years ago
- Views:
Transcription
1 Planning and Building Department 2012 B.C. Building Code Compliance Review PROJECT NAME:.. CIVIC ADDRESS: PERMIT APPLICATION NO.:. DATE:... I,, have: 1. reviewed the design, plans and supporting documents prepared by each of the Registered Professionals of Record for the above-noted project for compliance, in all material respects, with the requirements of Division A; Division B, Parts 1 and 3; and Division C of the BCBC in accordance with Appendix 1 - Compliance Checklist; 2. ascertained that the Registered Professionals of Record have incorporated in their plans and supporting documents submitted for building permit, the requirements of Division A; Division B, Parts 1 and 3; and Division C of the BCBC; and 3. ascertained that the requirements of Division A; Division B, Part 1 and 3; and Division C of the BCBC governing the above-noted project are compatible between the plans and supporting documents prepared by each of the Registered Professionals of Record. (Professional s Seal & Signature) Date *Except Articles & relative to fire safety plans conformance to BC Fire Code.
2 Appendix 1 - Compliance Checklist PERMIT APPLICATION NO.: 1 BUILDING DATA: Building Area (m 2 ): Building Height ( Storey): Mezzanine(s) Horizontal Fire Separation Firewalls: 2 hr 4 h Facing Streets (number): Major Occupancy(ies): Construction Articles: ; ; ; Construction Type Classification: NON-COMBUSTIBLE COMBUSTIBLE Fire Resistance Rating (hr): floor mezzanines roofs load bearing construction Sprinkler System: NFPA 13 NFPA 13R Standpipe system Fire Alarm System Building grade Div A First storey Div A Exemption for major occupancies; 10% rule but not F1/F2 Occupied roof rating Construction of storeys below ground High building Note: Where there is more than one building provide additional BUILDING DATA for each building B.C. Building Code Compliance Review 2 Created: 2018 May 07
3 2 SPATIAL SEPARATION: Exposing Building Face (EBF): Limiting Distance Area Exposing Building Face L/H Ratio % Opening Actual % Opening Allowed Type of Construction Fire Rating Cladding North South East West Openings protected L.D. <1.2 m Combustible projections 1.2 m from PL Projecting roof soffits Max. size opening L.D. <2.0 m Spacing of openings 2 m Exit facilities protected Wall exposed to another wall Protection of exposed soffit (if permitted by ) Wall exposed to adjoining roof Class A, B or C roof covering (1) (5) (6) / Location of fire department connection NFPA 20 compliance for fire pumps PROVISIONS FOR FIRE FIGHTING: Access above grade Access below grade Sprinklers required / Sprinkler standards Access route location and design Access to roof over 3 storeys Standpipes and hose connections B.C. Building Code Compliance Review 3 Created: 2018 May 07
4 4 ADDITIONAL REQUIREMENTS FOR HIGH BUILDINGS Application of high building requirements Requirements for limiting smoke movement Limit smoke movement for connected buildings Emergency operation of elevators Requirement for fire fighter elevators Venting to aid fire fighters CACF requirements Requirements for voice communication system FIRE SEPARATION BETWEEN OCCUPANCIES AND TENANTS, FLOOR AREAS AND SHAFTS: Separation of major occupancies / Table Prohibited combination of occupancies Fire separation between suites Fire separation for public corridor Fire separation for corridors serving an Assembly occupancy Fire separation for Residential occupancy Fire separation of Group A, Division occupancy (OL > 200 persons) Fire separation of roof supporting occupancy Walkway between buildings Underground walkways Fire separation of repair garages and storage / garages Vestibules (1) / Hazardous substances / BCFC 6 CONSTRUCTION OF FIRE SEPARATIONS AND CLOSURES: Basis for fire separations (Article of Appendix D, ULC/cUL/WH Listing) Protection of openings B.C. Building Code Compliance Review 4 Created: 2018 May 07
5 Support of fire separations Continuity of separations Fire-protection rating of closures Maximum openings in firewalls Maximum dimensions of openings Self closing devices Latches required on swing doors Wired glass and glass block in exit enclosures Wired glass and glass block in fire separations Temperature rise rated doors Fire dampers Hold-open devices 7 FIREWALLS: Prevention of collapse Rating Continuity Parapets Maximum openings Combustible projections 8 EXITS: / / / Table / / Table Occupant Load: Room Area (m²) Area/person (m²/person) = Total (persons) 2012 B.C. Building Code Compliance Review 5 Created: 2018 May 07
6 Types of exits Minimum of number of exits Distance between exits Travel distance and location of exits / Travel distance to exit in interstitial service space maximum 50 m Clear width of exit, corridor, stair, ramp and door Exit capacity: 6.1. mm/person for: ramps <= 1:8, doorways, corridors and passageways 9.2 mm/person for: ramps > 1:8, stairs (rise > 180 mm or run < 280 mm) 8 mm/person for stairs (rise < = 180 mm and run >= 280 mm) (3) / (8) / Table A & B Exit width encroachments permitted Headroom Flame spread rating for exits Table / Table Fire separation of exits / Exit lobby requirements Integrity of exits Minimum 3 risers (Exception ) Treads and risers Maximum of 3.7 m per flight, except Group B Length and width of landing Number and height of handrails Guards Number of handrails for stairs > 1100 mm Exit signs Sign for stair/ramp at exit level Gradients for ramps / Curved stairs Horizontal exits B.C. Building Code Compliance Review 6 Created: 2018 May 07
7 Exterior passageway and exceptions Exit at interconnected floor spaces Landings 300 mm wider and longer than door Door swing Sliding doors in exits Exit doors to be self-closing Release hardware Doors openable from inside without key Crossover floors in buildings greater than 6 storeys 9 SAFETY REQUIREMENTS WITHIN FLOOR AREAS: / (6) / / Means of egress from roof and terraces (3) Doors into public corridor, exit in opposite directions Roof top enclosure > 200 m², 2 means of egress 2 means of egress required for service spaces greater than 200 m² or travel distance > 25 m 2 egress doorways; min. 1/3 diagonal separation Travel distance Headroom clearance Doors in access to exit: Minimum 800 mm for single leaf clear openin8 Minimum 800 mm for active leaf in double door Clear and level areas adjacent to doors Readily openable without use of keys Door hardware and installation requirements Not open onto a step Hazardous substances Design of hazardous areas (9) (6) (7) / BCFC / BCFC 2012 B.C. Building Code Compliance Review 7 Created: 2018 May 07
8 Door swing : Occupant load > 60 or F1 occupancy must swing in direction of exit travel Minimum width of corridor Capacity of access to exit: Corridors, passageways, doorways, and ramps not more than 1in mm/person Stairs Ramps > 1 in mm/person B2 and B3 occupancies 18.4 mm/person Guards at roof, shaft, balcony, etc. Protection of openable windows Explosion venting Flame spread rating Flame spread rating in elevator cars Ventilation for commercial cooking equipment Foam plastics protection in: Combustible construction Non-combustible construction Requirements by occupancy: Assembly A1, A2, A3, A4 Detention B1, Treatment B2, Care B3 Residential C Industrial F1, F2, F3 STC to conform to Section 5.9 for residential occupancies 10 LIGHTING AND EMERGENCY POWER: / (3) / (1) (8) (2) / Table (2) Lighting for exits, public corridors, and rooms Emergency lighting Emergency power for lighting Emergency power for fire alarm systems Emergency power for B2 occupancies B.C. Building Code Compliance Review 8 Created: 2018 May 07
9 Emergency power for building services Emergency conductor protection 11 FIRE ALARMS: Buildings requiring a fire alarm system Continuity of fire alarm systems Types of systems / System descriptions Signals to fire department Zoning of fire alarm systems Fire detectors Smoke detectors Sprinkler system monitoring Manual pull stations Visual signals Smoke alarms Voice Communication system / REQUIREMENTS FOR MEZZANINES AND INTERCONNECTED FLOOR SPACES: 10% mezzanine (not a storey) 40% mezzanine (not a storey) Termination of vertical fire separation Mezzanine egress Interconnected floor space not permitted in B2 occupancy Openings through horizontal fire separation for vehicular ramps in storage garage Openings in fire separation for manufacturing process Openings for stairways, escalators, moving walkways Interconnected first floor and floor below or above Construction of interconnected floor space noncomb (2) (3) (5)/(6) (6) Exit requirements (6) 2012 B.C. Building Code Compliance Review 9 Created: 2018 May 07
10 Elevator openings (3) Sprinkler system Draft stops Mechanical Exhaust Systems (smoke control) SERVICE FACILITIES: No storage in services spaces Fire separation of service rooms Door swing No boiler under exit Fire separation of janitor rooms Fire separation of laundry rooms Fire separation and sprinklers for residential storage rooms Fire separation of electrical equipment vaults Fire separation for elevator shafts Fire separation for vertical services spaces Fire separations for elevator machine room Elevator car dimensions for stretchers Fire separation at top/bottom of vertical service space Fire separation of horizontal service spaces Fire separation of fuel fired service Fire separation and sprinklers for garbage and recycling rooms Fire separation for generator room for emergency power Linen and garbage chutes and rooms Negative pressure required for vertical service space Ceiling spaces used as plenums Ceiling panels hold-down clips Access to attic or roof space / Table / Table B.C. Building Code Compliance Review 10 Created: 2018 May 07
11 Access to horizontal service space Access to crawl space HEALTH REQUIREMENTS: Height in sleeping rooms / Room ventilation / Medical gas piping systems / CSA Z Plumbing Facilities: Occupancy # of persons of each sex # of water closets required # of water closets provided 15 REQUIREMENTS FOR DISABLED PERSONS: When required: Application and exemptions Areas requiring barrier-free path of travel Existing buildings Main entrances Width of path of travel minimum 1500 mm Ground and floor surfaces Viewing positions Parking: Access to parking areas / Number of stalls required m wide Identification required Surface treatment B.C. Building Code Compliance Review 11 Created: 2018 May 07
12 Accessible washrooms: Where required Water closet stalls min mm x 1500 mm (2) Door min. 800 mm clear opening (2) Water closets (3) Location of urinals (6) Grab bars, wash basins, mirrors (4) / (5) / (7) Universal toilet rooms (9) Bathtubs (10) Showers (11) Doors and vestibules in barrier-free path (10) / (11) / (12) Power doors in hotels, B2, B3, A, D, or E > 500 m² (4) Ramps: Minimum width 915 mm or 1500 mm Maximum gradient Handrails and guards Elevators / CSA B44 Other: Specific occupancy requirements: Egress from accessible floor areas Adaptable dwelling unit requirements Access requirements for buildings containing adaptable B.C. Building Code Compliance Review 12 Created: 2018 May 07
13 16 ALTERNATIVE SOLUTIONS: Alternative Solutions Report: Submitted / Required / Not Required Summary of the Alternative Solution(s): 2012 B.C. Building Code Compliance Review 13 Created: 2018 May 07
PROJECT: CIVIC ADDRESS:... PERMIT APPLICATION NO.: DATE:... CRP:. Certified Professional:.
2012 B.C. Building Code Checklist (Division B Part 3) This checklist is provided as a reference only. The submission of this checklist with a Building Permit application should not be considered as a substitute
More informationBC Building Code Checklist Part 3 Planning and Development Department
BC Building Code Checklist Part 3 Planning and Development Department Project: Civic address: Permit No.: CRP: Certified Professional: Date: 1 Value of Construction: $ Developed Site Area: m2 2 BUILDING
More informationBOABC Level III Exams 7, 8, 9 and 10 Beginning April 1, 2015
Exam ID Examination Code Part BOABC Level III Exams 7, 8, 9 and 10 Beginning April 1, 2015 BC3-7 Level III Exam 7 BCBC Part 3 (Part 3 Buildings Classification & Construction) BC3-8 Level III Exam 8 BCBC
More informationBCBC 2012 CHANGES TO PART 3
BCBC 2012 CHANGES TO PART 3 Focus on changes that will have an practical effect. Basic concepts reviewed details to be confirmed. Material from Part 3 and related material from Part 9 Generally a harmonization
More informationCHAPTER 7 ALTERATIONS LEVEL
CHAPTER 7 ALTERATIONS LEVEL 2 SECTION 701 GENERAL 701.1 Scope. Level 2 alterations as described in Section 404 shall comply with the requirements of this chapter. Exception: Buildings in which the reconfiguration
More informationShort Term Accommodations Fire Code Requirements
Short Term Accommodations Fire Code Requirements 1 Foreward The following is a comprehensive reference to Retrofit 9.3 of Division B of the Ontario Fire Code (OFC). Retrofit provisions were developed to
More informationCOURSE SYLLABUS HVAC AND MECHANICAL CONSIDERATIONS FOR PART 3 BUILDINGS CORRESPONDENCE COURSE
COURSE SYLLABUS HVAC AND MECHANICAL CONSIDERATIONS FOR PART 3 BUILDINGS CORRESPONDENCE COURSE 100126 The course is organized into three bands. Band A covers HVACrelated building components and other types
More informationAt the Montréal city council meeting of April 10, 1995, it was enacted that:
CITY OF MONTRÉAL BY-LAW 95-065 BY-LAW AMENDING THE BUILDING BY-LAW (B-1) At the Montréal city council meeting of April 10, 1995, it was enacted that: 1. Article 3 of the Building By-law (R.B.C.M., chapter
More informationRental Housing Initial Inspection Checklist Community Development Department 208 NW 1 st Ave., Faribault, MN
Rental Housing Initial Inspection Checklist Community Development Department 208 NW 1 st Ave., Faribault, MN 55021 www.faribault.org (507) 333-0359 Property Address: Number of Units Building Type Name
More informationBuilding & Fire Code Academy. Building Better With Our Greatest Resource Education. Welcome!
Building & Fire Code Academy Building Better With Our Greatest Resource Education Welcome! Understanding the Sprinkler System Design Alternatives in the 2015 International Why inspect, test and maintain?
More information150 Elgin - Office Tower and Grant House Renovations
APPLICATION OF THE ONTARIO BUILDING CODE 150 Elgin - Office Tower and Grant House Renovations 150 Elgin Street Ottawa, Ontario Presented to: Mr. Brandon Donnelly Morguard Investments Limited c/o Mr. Harry
More informationPLAN REVIEW SUBMITTAL GUIDE
PLAN REVIEW SUBMITTAL GUIDE Plans, specifications and other construction documentation for the initial plan review should be as complete as possible at the time of submittal. Use this convenient guide
More informationFIRE SAFETY UPGRADING CONSIDERATIONS for EXISTING SENIOR CITIZEN LODGES
FIRE SAFETY UPGRADING CONSIDERATIONS for EXISTING SENIOR CITIZEN LODGES 1. The major objective is to provide an acceptable degree of life safety from fire in existing senior citizen lodges. This document
More informationLife Safety - Means of Egress/Exits NFPA 101
Life Safety - Means of Egress/Exits NFPA 101 Properly designed exits provide a safe path of escape from a fire or other emergency environment. The means of egress (exits) should be arranged to permit all
More informationBUILDING CODE OF THE CITY OF NEW YORK. New York City Department of Buildings 4 June 2007
BUILDING CODE OF THE CITY OF NEW YORK New York City Department of Buildings 4 June 2007 Fatma Amer, PE, Deputy Commissioner, Technical Affairs James Colgate, RA, Executive Architect John Lee, RA Keith
More informationSCHEDULE. Essential Safety Measures taken from Schedule 9 of the Building Regulations PART 1 BUILDING FIRE INTEGRITY
SCHEDULE Essential s taken from Schedule 9 of the Building Regulations 2006 43 PART 1 BUILDING FIRE INTEGRITY 1 Building elements required to satisfy prescribed fire-resistance levels 2 Materials and assemblies
More informationFIRE SAFETY INSPECTION REPORT
FIRE SAFETY INSPECTION REPORT M.S.ATTIRES LTD. ACCORD ID: 10887 A. RAHMAN PLAZA, SHANSHONGAON, FATULLAH, NARAYANGONJ OTHER FACTORIES: AISA FASHION LTD.; PRINT GARDEN LTD.; S.M. COLLECTION LTD. February
More informationAgency for Health Care Administration
Page 1 of 92 FED - K0000 - INITIAL COMMENTS Title INITIAL COMMENTS Type Memo Tag FED - K9999 - FINAL OBSERVATIONS Title FINAL OBSERVATIONS Type Memo Tag FED - KA100 - General Requirements - Other Title
More informationFIRE SAFETY INSPECTION REPORT
FIRE SAFETY INSPECTION REPORT RAISA FASHIONS LTD. ACCORD ID: 11741 PLOT# B63, BSCIC INDUSTRIAL ESTATE, KANCHPUR, SONORGAON, NARAYANGANJ OTHER FACTORIES: NONE February 27, 2015 Page 2 SUMMARY was surveyed
More informationINTERIOR FINISH REVIEW
APPR NO. FIRE CODE COMPLIANCE ITEM I000 I001 I005 I010 I015 I020 INTERIOR FINISH Plans shall bear the seal of a licensed Architect currently registered with the State of Georgia are required for final
More informationRental Housing Inspection Guide
BOONE FIRE DEPARTMENT Rental Housing Division 515-432-3446 www.boonegov.com/rental BUILDING DEPARTMENT Rental Housing Inspection Guide Boone Fire Department Welcome to the Rental Housing Inspection Guide
More informationCity of South Salt Lake Fire Code Training Exiting, Egress Systems and Egress Control
City of South Salt Lake Fire Code Training Exiting, Egress Systems and Egress Control 11-27-12 This document is designed as a summary guide using IFC requirements for the provisions associated with exiting,
More informationFIRE SAFETY INSPECTION REPORT
FIRE SAFETY INSPECTION REPORT MAHID APPAREL LTD ACCORD ID: 11956 NOWPARA, MADHABDI, NARSINGDI, DHAKA-1604 OTHER FACTORIES: NONE February 20, 2015 Page 2 SUMMARY was surveyed for fire safety on 2/20/2015
More informationMajor Changes to the 2010 National Construction Codes Contractor s Breakfast January 2014
Major Changes to the 2010 National Construction Codes Contractor s Breakfast January 2014 Philip Rizcallah, P. Eng. NRC-IRC Canadian Codes Centre Presented by Stan Dueck CRBO Overview Where are the major
More informationBUILDER S PRE-INSPECTION CHECKLIST
Warrenton Fire Protection District 606 Fairgrounds Rd. Warrenton, MO 63383 Ph: 636-456-8935 Fax: 636-456-7764 www.warrenton-fire.org BUILDER S PRE-INSPECTION CHECKLIST This checklist is designed as a general
More information2012 OBC Changes. Summary of key changes to Life Safety and Fire Protection Systems for CFAA January 22, 2014
2012 OBC Changes Summary of key changes to Life Safety and Fire Protection Systems for CFAA January 22, 2014 2012 OBC New Sentence 3.2.4.2(6) Buildings interconnected by walkways permitted in Articles
More informationFIRE SAFETY INSPECTION REPORT
FIRE SAFETY INSPECTION REPORT PORTLAND TEXTILE LTD. ACCORD ID: 11873 PLOT NO. 14-15, SECTOR 6, CHITTAGONG EXPORT PROCESSING ZONE, CHITTAGONG OTHER FACTORIES: NONE November 3, 2015 Page 2 SUMMARY was surveyed
More informationResidential-based Care Facility R-4 Guideline
Moreno Valley Fire Department Fire Prevention Bureau Residential-based Care Facility R-4 Guideline Approved and Authorized By: Adria Reinertson, Fire Marshal Issued: April 7, 2017 Residential-based Care
More informationBUILDER S PRE-INSPECTION CHECKLIST
Warrenton Fire Protection District 606 Fairgrounds Rd. Warrenton, MO 63383 Ph: 636-456-8935 Fax: 636-456-7764 www.warrenton-fire.org BUILDER S PRE-INSPECTION CHECKLIST This checklist is designed as a general
More informationNFPA 101 Code Update from 2012 Edition to the 2015 Edition
NFPA 101 Code Update from 2012 Edition to the 2015 Edition Presented by: Gary Furdell AHCA Fire Protection Specialist 1 2 2012 Update to 2015 Chapter 18 New Health Care Occupancies 4 18.1.3.2 Atrium walls
More informationResidential Care Facilities Requirements
Development Services Department Building Division 311 Vernon Street Roseville, California 95678-2649 Residential Care Facilities Requirements SUBMITTAL REQUIREMENTS: Note: These requirements are in addition
More informationInterim Amendments to Ontario s 2012 Building Code Retirement Homes. August 17, 2017
Interim Amendments to Ontario s 2012 Building Code Retirement Homes August 17, 2017 Notice This presentation is intended for general information purposes only. It is not intended as legal or technical
More informationWORKSHEET 2-1 THE MANITOBA RESIDENTIAL OCCUPANCY FIRE RISK INDEX FIRE SAFETY PARAMETER VALUES
1 WORKSHEET 2-1 THE MANITOBA RESIDENTIAL OCCUPANCY FIRE RISK INDEX FIRE SAFETY PARAMETER VALUES TABLE 2.1 CONSTRUCTION OF STRUCTURAL MEMBERS AND FLOOR AND ROOF (1) ASSEMBLIES (Applies to each fire zone)
More informationPENNSYLVANIA. Downloaded
Housekeeping/Laundry/Maintenance 205.26. Laundry. PENNSYLVANIA Downloaded 01.15.11 (a) A laundry room shall be provided in a facility where commercial laundry service is not used for the washing of soiled
More information12/14/2013. Fire alarm and emergency power SPRINKLER HEAD
Fire alarm and emergency power SPRINKLER HEAD 1 Alert signal Alarm signal Fire detector Heat detector Smoke detector Smoke alarm 1. Detector locations 1. Fire detector locations (3.2.4.11) 2. Smoke detector
More informationJanuary 1, 2014 Mandatory Effective Date
2013 Kentucky Building Code Highlights Winnie Blythe, Technical Advisor Dept. of Housing, Buildings, and Construction winnie.blythe@ky.gov www.dhbc.ky.gov 502-573-0373 January 1, 2014 Mandatory Effective
More informationHCD DSA OSHPD 1 2 1/AC AC SS SS/CC
CALIFORNIA BUILDING CODE MATRIX ADOPTION TABLE CHAPTER 30 ELEVATORS AND CONVEYING SYSTEMS (Matrix Adoption Tables are non-regulatory, intended only as an aid to the user. See Chapter 1 for state agency
More informationINITIAL FIRE SAFETY ASSESSMENT
INITIAL FIRE SAFETY ASSESSMENT Factory Assessor: Plot no. A102, BSCIC Industrial Estate, Tongi, Gazipur Tongi, Gazipur Emkay Enterprises 06 Jul 2014 The Alliance for Bangladesh Worker Safety Page 1/22
More informationSecondary Suites. Guidelines for the construction of Accessory Secondary Suites in the City of Abbotsford August
Secondary Suites Guidelines for the construction of Accessory Secondary Suites in the City of Abbotsford August 2015 PLANNING & DEVELOPMENT SERVICES Building Permits & Licences 1st Floor, 32315 South Fraser
More informationSANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST
July 1, 2010 SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST TENANT IMPROVEMENTS Address: Permit #: Inspector: Date: Status: Inspector: Date: Status: A-Approved; AC-Approved w/comments;
More informationFIRE SAFETY INSPECTION REPORT
FIRE SAFETY INSPECTION REPORT YOUNG INTERNATIONAL PLOT NO. 32-36, SECTOR 5-CEPZ, CHITTAGONG OTHER FACTORIES: NONE July 20, 2014 Page 2 SUMMARY was surveyed for fire safety on 7/20/2014 by Hughes Associates,
More information1. The provisions of paragraph (D)(1104) of this rule shall apply to all existing buildings.
ACTION: Final DATE: 12/04/2017 11:44 AM 1301:7-7-11 Construction requirements for existing buildings. (A) Section 1101 General (1) 1101.1 Scope. The provisions of this rule shall apply to existing buildings
More informationFor the Florida Building Commission And the Fire Code Advisory Council
Life-Safety Modifications Mechanical and Existing Building Compared to the 2012 Changes of the International Building Code and National Fire Protection Association- 101 For the Florida Building Commission
More informationBritish Columbia Building Code 2006 Division B Part 3 Fire Protection, Occupant Safety and Accessibility Section 3.2 Building Fire Safety
Div B 3.2.1.1.(4), (5) & (6) Exceptions in Determining Building Height BCBC1998-3.2.1.1.(4), (5) & (7) replace (harmonize with NBC) - NBC 2005 has significant revisions to provisions for mezzanines. These
More informationEQUIVALENT INITIAL FIRE SAFETY ASSESSMENT
EQUIVALENT INITIAL FIRE SAFETY ASSESSMENT Vill: Golora, Post: Kaitta P.S. Saturia, Manikgonj Manikgonj, Dhaka The Alliance for Bangladesh Worker Safety Page 1/14 Introduction to the Report The following
More informationBuilding Standards Advisory Promoting construction of safe, healthy, habitable buildings
Building Standards Advisory Promoting construction of safe, healthy, habitable buildings Saskatchewan Amendments to the National Building Code 2015 In Canada, provincial and territorial governments have
More informationMajor Changes Nova Scotia Building Code 2011 Construction and Maintenance Regulatory Change Industry Briefing
Major Changes Nova Scotia Building Code 2011 Construction and Maintenance Regulatory Change Industry Briefing Ted Ross Labour & Advanced Education Gerard Donahoe Labour & Advanced Education Overview Where
More informationAHC Meeting #7 July 12-13, Occupancy WG Report
AHC Meeting #7 July 12-13, 2012 Part 1: CTC public comments on I-1/I-2 Condition designations..page 1 Part 2; AHC public comments on I-2 Condition designations Page 6 Part 3: Approved code change G244
More informationPart 3 BUILDING CODE MYTHS & INTERPRETATIONS
Part 3 BUILDING CODE MYTHS & INTERPRETATIONS November 18, 2016 Frank Durante, RBO Building Inspector District of Mission Phone 604 820 3729 Wendy Morrison, AScT, BCQ GHL CONSULTANTS LTD Fire Science and
More informationFIRE SAFETY INSPECTION REPORT
FIRE SAFETY INSPECTION REPORT MULTIFABS LTD KASHIMPUR, NAYAPARA Other Factories: ne April 9, 2014 Page 2 Fire Safety Inspection Report Introduction manufacturing complex was surveyed for fire safety on
More informationM E M O R A N D U M. Diane Matthews, Administrator, Technical Projects. NFPA 101 First Draft Letter Ballot (A2014)
National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169 7471 Phone: 617 770 3000 Fax: 617 770 0700 www.nfpa.org M E M O R A N D U M TO: FROM: NFPA Technical Committee on Means of Egress
More informationENERGY EFFICIENCY AFTER DECEMBER 31, 2016
MODULE 2 Energy Efficiency INTRODUCTION In this module the requirements for energy efficiency in buildings is examined with particular attention to the Supplementary Standard to the OBC, SB-10, Energy
More informationGeneral Kitchen, Bath & Bedroom Remodeling Notes County of Marin, Building Inspection Division
These Notes are intended to assist in issuing simple remodel permits. It provides information on the most common requirements relating to the construction or remodeling of kitchens, bathrooms and bedrooms.
More information2009 International Fire Code Errata. SECOND PRINTING (Posted April 6, 2010)
CHAPTER 1 SCOPE AND ADMINISTRATION 102.7 Referenced codes and standards. The codes and standards referenced in this code shall be those that are listed in Chapter 45 47 and such codes and standards shall
More informationResidential Based Care Facility Guidelines
Moreno Valley Fire Department Fire Prevention Bureau Residential Based Care Facility Guidelines Approved and Authorized By: Randall Metz, Fire Marshal Issued: January 1, 2011 Residential Based Care Facilities
More informationSPECIAL DETAILED REQUIREMENTS BASED ON USE AND OCCUPANCY
CHAPTER 4 SPECIAL DETAILED REQUIREMENTS BASED ON USE AND OCCUPANCY SECTION 401 SCOPE 401.1 Detailed use and occupancy requirements. In addition to the occupancy and construction requirements in this code,
More informationCFAA Technical Seminar Ontario Building Code Updates to 2015
CFAA Technical Seminar Ontario Building Code Updates to 2015 October 28, 2015 2015 Fire Alarm Updates Ontario Building Code Glenn Somerton P.Eng. Senior Code Specialist Morrison Hershfield Limited gsomerton@morrisonhershfield.com
More informationFIRE SAFETY INSPECTION REPORT
FIRE SAFETY INSPECTION REPORT DANNY'S KNITWEAR LTD. ACCORD ID: 12228 SURABARI, GAZIPUR, SADAR, GAZIPUR Other Factories: ne October 17, 2015 Page 2 Fire Safety Inspection Report Introduction manufacturing
More informationOsceola County Department of Fire Rescue and Emergency Medical Services
St. Number Dir Street Name Street Type Inspected Time of Day to be Re-inspected Zip Code Occupancy Type Emergency Contact Phone (Inc. Area Code) Building Owner Building Owner Mailing Address Bldg. Owner
More informationMINOOKA FIRE PROTECTION DISTRICT Fire Prevention Bureau Fire Inspector Rodney Bradberry
MINOOKA FIRE PROTECTION DISTRICT Fire Prevention Bureau Fire Inspector Rodney Bradberry Fire Alarm Systems Plan Review Checklist Date: Permit Number: Business Name: Address: Fire Alarm System Submittal
More informationSURREY FIRE SERVICE. Construction Fire Safety Plan Bulletin
SURREY FIRE SERVICE Construction Fire Safety Plan Bulletin The B.C. Fire Code requires building owners/contractors to comply with the requirements of the BC Fire Code 5.6 Construction and Demolition Sites
More informationChapter Nursing Homes
Chapter 16.01 Nursing Homes Section 1. Licensing. No nursing, convalescent or old age home, as defined in Section 2 of this ordinance, shall be operated except under a license from the City Council of
More informationINITIAL FIRE SAFETY ASSESSMENT
INITIAL FIRE SAFETY ASSESSMENT Factory Address: Plot 1175 & 1179, Bashan Sarak, Vogra, PO. National University, Gazipur Sadar, Gazipur Gazipur Dhaka Bangladesh 15 Jun 2016 The Alliance for Bangladesh Worker
More informationBurien/Normandy Park Fire Department 900 SW 146 th ST PO Box Burien, WA BP (206) Fax (206)
Burien/Normandy Park Fire Department 900 SW 146 th ST PO Box 66029 Burien, WA 98166 BP (206) 242-2040 Fax (206) 433-6042 HOME DAYCARE SELF-INSPECTION CHECKLIST ` Complete the following daycare checklist,
More informationWORKSHEET 4-1 THE MANITOBA FIRE RISK INDEX FOR THE RESIDENTIAL OCCUPANCY OF HERITAGE BUILDINGS FIRE SAFETY PARAMETERS
1 WORKSHEET 4-1 THE MANITOBA FIRE RISK INDEX FOR THE RESIDENTIAL OCCUPANCY OF HERITAGE BUILDINGS FIRE SAFETY PARAMETERS TABLE 4.1 CONSTRUCTION OF STRUCTURAL MEMBERS AND FLOOR AND ROOF ASSEMBLIES Construction
More informationModule 9: Ontario Building Code Fire Fighting Provisions
Ontario Building Code (OBC) 1. Sprinklers 2. Standpipes 3. Fire Alarms 4. Entrances Ontario Building Code (OBC) 1. Sprinklers 2. Standpipes 3. Fire Alarms 4. Entrances 1. Sprinklers i) Sprinkler Systems
More informationSPECIAL DETAILED REQUIREMENTS BASED ON USE AND OCCUPANCY
CHAPTER 4 SPECIAL DETAILED REQUIREMENTS BASED ON USE AND OCCUPANCY SECTION 401 SCOPE 401.1 Detailed use and occupancy requirements. In addition to the occupancy and construction requirements in this code,
More information2018 IFC Update. Based on the 2018 International Fire Code, (IFC ) Goal. Objectives. Content
Based on the 2018 International Fire Code, (IFC ) The International Fire Code (IFC ), establishes minimum regulations for fire safety. This handout will identify important changes in the IFC from 2015
More informationBalloting Version First Draft NFPA 101 Life Safety Code Proposed 2015 Edition
Copyright National Fire Protection Association 2013. All rights reserved. This copy is solely for your personal, noncommercial use in connection with participation in the NFPA Standards Development Process.
More informationSANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU STANDARD
July 1, 2010 SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU STANDARD LICENSED CARE FACILITIES SCOPE: This standard provides requirements for licensed care facilities known as for the Elderly with seven
More informationDate: February 22, 2005 Kimbalton DUSEL, Pre-S-2 Submittal CNA0402 PRELIMINARY CODE REVIEW. International Plumbing Code Edition
Kimbalton DUSEL Preliminary Code Study CNA0402 Date: Project: February 22, 2005 Kimbalton DUSEL, Pre-S-2 Submittal CNA0402 Note: Shaded Sections not complete. PRELIMINARY CODE REVIEW Building Code: International
More informationFor additional information regarding R-3.1 residential care facilities please contact (951)
Riverside County Fire Department Fire/Life Safety Inspection Division Riverside Office: 2300 Market St., Ste. 150, Riverside, CA 92501 Ph. (951) 955-4823 Fax (951) 955-4886 Palm Desert Office: 77-933 Las
More informationINITIAL FIRE SAFETY ASSESSMENT
INITIAL FIRE SAFETY ASSESSMENT Factory Name: Assessor: Anzir Apparels Limited, Unit-1 Karim supermarket, Baipal, Baipal, Savar Savar Dhaka Bangladesh Emkay Enterprises 30 Apr 2014 The Alliance for Bangladesh
More informationEQUIVALENT INITIAL FIRE SAFETY ASSESSMENT
EQUIVALENT INITIAL FIRE SAFETY ASSESSMENT Factory Plot # 33-36 Sector # 07, Chittagong Chittagong Chittagong 08 Jun 2014 The Alliance for Worker Safety Page 1/18 08 Jun 2014 Introduction to the Report
More informationFIRE SAFETY INSPECTION REPORT
FIRE SAFETY INSPECTION REPORT COMFORT APPAREL, ( PVT ) LTD. 96, DARUS SALAM, MIRPUR, DHAKA OTHER FACTORIES: SALMA FASHION WEARS LTD, COMFORT KNIT FASHION LTD March 27, 2014 Page 2 SUMMARY was surveyed
More informationEQUIVALENT INITIAL FIRE SAFETY ASSESSMENT
EQUIVALENT INITIAL FIRE SAFETY ASSESSMENT 171-181, Baizid Bostami Road Nasirabad I/A, Chittagong Chittagong The Alliance for Bangladesh Worker Safety Page 1/14 Introduction to the Report The following
More informationINITIAL FIRE SAFETY ASSESSMENT
INITIAL FIRE SAFETY ASSESSMENT Factory Plot No -246-249, Adamjee EPZ, Siddhirganj, Narayanganj Narayanganj 17 Jul 2016 The Alliance for Bangladesh Worker Safety Page 1/17 Factory 17 Jul 2016 Introduction
More informationMULTI-LEVEL & COVERED BOOTH CONDITIONS
MULTI-LEVEL & COVERED BOOTH CONDITIONS Covered Booth Definition To place something over or upon an exhibit or portion of an exhibit (e.g., roof, ceiling, tenting, lattice, fabric, plastic) to cover the
More informationThe one-half hour seminar in module 2 that follows, will complete the remainder of chapter 3, building planning, already begun in module 1.
The one-half hour seminar in module 2 that follows, will complete the remainder of chapter 3, building planning, already begun in module 1. 1 This new alternative testing standard for safety glazing, can
More informationHIGH-RISE RETROFIT ORDINANCES - NO and NO
INFORMATION BULLETIN / PUBLIC - BUILDING CODE REFERENCE NO.: LAMC 91.8604 Effective: 9-06-90 DOCUMENT NO. P/BC 2002-054 Revised: 4-15-03 Previously Issued As: MGD 88 HIGH-RISE RETROFIT ORDINANCES - NO.
More informationAgency for Health Care Administration
Page 1 of 100 FED - K0000 - INITIAL COMMENTS Title INITIAL COMMENTS CFR Type Memo Tag FED - K9999 - FINAL OBSERVATIONS Title FINAL OBSERVATIONS CFR Type Memo Tag FED - KA100 - General Requirements - Other
More informationSPECIAL DETAILED REQUIREMENTS BASED ON USE AND OCCUPANCY
CHAPTER 4 SPECIAL DETAILED REQUIREMENTS BASED ON USE AND OCCUPANCY SECTION 401 SCOPE 401.1 Detailed use and occupancy requirements. In addition to the occupancy and construction requirements in this code,
More informationUse a minimum loading pad 6' curb length of a hard surface to connecting curb and sidewalk.
Appendix H ACCESSIBILTY The AODA Built Environment Standard is currently in development by a committee of people from the business and public communities, as well as persons with disabilities. The public
More informationSAFETY. USE OF SAFETY CHECK LISTS A safety check for compliance with current regulations should be performed yearly.
SAFETY GENERAL Buildings must be designed according to building and fire safety codes and other regulatory standards at the time of construction. However, such codes and standards are continuously changing.
More informationFIRE SAFETY INSPECTION REPORT
FIRE SAFETY INSPECTION REPORT ALAUDDIN GARMENTS LTD. 88, KAZI NAZRUL ISLAM AVENUE, TAJGAON, DHAKA- 1215 OTHER FACTORIES: CAMBRIDGE GARMENTS, PRIMODIAL April 27, 2014 Page 2 SUMMARY was surveyed for fire
More informationDenver Fire Department Fire Prevention Division
/A 505.1 505.1 Address: Clearly marked from street, Arabic numbers or alphabetical letters. Numbers shall not be spelled out. Address identification characters shall contrast with their background. Each
More informationINITIAL FIRE SAFETY ASSESSMENT - EXPANSION
INITIAL FIRE SAFETY ASSESSMENT - EXPANSION 228/1, Tin Sharak, Luxmipura, Joydevpur, Gazipur Joydebpur, Gazipur The Alliance for Bangladesh Worker Safety Page 1/18 Introduction to the Report The following
More informationBALTIMORE CITY RENTAL LICENSE INSPECTION FORM RENTAL LICENSING INSPECTOR GUIDANCE
BALTIMORE CITY RENTAL LICENSE INSPECTION FORM RENTAL LICENSING INSPECTOR GUIDANCE Checklist items A - L may receive a result of Pass or Fail A. Railing is present for interior and exterior steps with more
More informationWashoe County Department of Social Services
SECTION 30 FIRE AND LIFE SAFETY REQUIREMENTS 30.1 Authority to inspect. The facility shall meet all fire and life safety standards. Fire department inspectors shall have authority to enter, for purposes
More informationRecommended Amendments to the 2015 International Existing Building Code North Central Texas Council of Governments Region
Recommended Amendments to the 2015 International Existing Building Code North Central Texas Council of Governments Region The following sections, paragraphs, and sentences of the 2015 International Existing
More informationThe course only requires the latest edition of the following documents: Building Code Compendium, Volume 1 and 2.
MODULE 1 INTRODUCTION AND INSTRUCTIONS ADMINISTRATIVE REQUIREMENTS flipchart. When asked by the Facilitator, the spokesperson will explain the group s answer, which forms the basis for class discussion.
More informationSANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU INSPECTION GUIDELINE RESIDENTIAL CARE FACILITIES 2007 CBC/CFC (R-3.1)
July 1, 2010 SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU INSPECTION GUIDELINE RESIDENTIAL CARE FACILITIES Address: Permit #: Inspector: Date: Status: Inspector: Date: Status: This Checklist outlines
More informationPROPOSED Houston Amendments to the 2015 International Building Code
PROPOSED Houston Amendments to the 2015 International Building Code Where there is no specific change justification, the change is being proposed in order to be consistent with historical code amendments
More informationDUCT SYSTEMS CHAPTER 6
SECTION 601 GENERAL 601.1 Scope. Duct systems used for the movement of air in air-conditioning, heating, ventilating and exhaust systems shall conform to the provisions of this chapter except as otherwise
More informationThe Residences at Christina Landing Wilmington, DE
5.0 FIRE PROTECTION EXISTING CONDITIONS 5.1 Project Specific Fire Protection Data Codes, Regulations, and Standards Building Officials and Code administrators (BOCA) National Building Code [1996] with
More informationConversion to Vacation Home Permit Life Safety Survey
P.O. Box 1190, Fort Collins, Colorado 80522-1190, Planning (970) 498-7683 Building (970) 498-7700, Larimer.org Conversion to Vacation Home Permit Life Safety Survey All dwellings used as short-term rentals
More informationFIRE SAFETY INSPECTION REPORT
FIRE SAFETY INSPECTION REPORT PADMA SWEATERS LTD. 1/B DARUS SALAM ROAD, SECTION 1. MIRPUR OTHER FACTORIES: NONE. July 9, 2014 Page 2 SUMMARY was surveyed for fire safety on 7/9/2014 by Hughes Associates,
More informationEQUIVALENT INITIAL FIRE SAFETY ASSESSMENT
EQUIVALENT INITIAL FIRE SAFETY ASSESSMENT Assessor: Konabari, Neelnagar, Gazipur Gazipur Dhaka Bangladesh Uttaron The Alliance for Bangladesh Worker Safety Page 1/13 Introduction to the Report The following
More informationShort-Term & Accessory Short-Term Rental Safety Certification
Short-Term & Accessory Short-Term Rental Safety Certification Permit Application Center (City Hall) 555 Liberty St. SE, Room 320 Salem, OR 97301 503-588-6213 (For office use only) License #: If you need
More informationINITIAL FIRE SAFETY ASSESSMENT
INITIAL FIRE SAFETY ASSESSMENT Factory Assessor: 107/112 Nazrul Market 1st & 2nd floor, Chawk Bazar, Chittagong Emkay Enterprises 09 Apr 2014 The Alliance for Bangladesh Worker Safety Page 1/28 Factory
More information