FS20 Fire detection system

Size: px
Start display at page:

Download "FS20 Fire detection system"

Transcription

1 FS20 Fire detection system Components / Spare parts / Repair parts Market package Control Products and Systems

2 Legal notice Technical specifications and availability subject to change without notice. Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its contents and communication thereof to others without express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model or design patent are reserved. Issued by: Siemens Switzerland Ltd. Division International Headquarters Gubelstrasse 22 CH-6301 Zug Tel Edition: Document ID: Siemens Switzerland Ltd,

3 1 About this document Fire control panels FC2020 fire control panels (2-loop) in housing (Standard) FC2020 fire control panels (2-loop) in housing (Comfort) FC2030 Fire control panel (Modular) for modernization FC2040 Fire control panels (4-loop) FC2060 Fire control panel (Modular) in housing (Large) FC2080 Fire control panel (Modular) Control panel expansion License key Event printer Mounting plate Fire brigade periphery module Sounder module Network module (SAFEDLINK) Repeater (SAFEDLINK) Accessories for Repeater RS485 module RS232 module FCC2004-A FCC2005-A FCC2008-D FCA2007-A FCA2008-A Loop extension (FDnet) Line card (FDnet) Line card (collective) Accessories line card (collective) Line card (MS9i) Line card (AnalogPLUS) Line card (Interactive) Line card (Interactive-Ex) I/O card (programmable) Network components Housing Standard and Large Extension (empty) Housing Comfort and Large (empty) Operating add-ons Operating units Auxiliary power supply Accessories for control panels Key switches Relay module " mounting kit Carrier 19" Cable kit (communication) FM-blinds Matrix printer (Extern)

4 3 Fire terminals FT2040 fire terminals in housing (Eco) Fire terminal expansion License key Event printer Network module (SAFEDLINK) RS485 module RS232 module Network components Power supply kit (70 W) Housings (Eco) Operating add-ons Fire terminal accessories Key switch " mounting kit Cable kit (communication) FM-blind 1HU Floor repeater display and floor repeater terminal Floor repeater terminals Floor repeater display Accessory for floor repeater terminal FT2010-A Accessory for floor repeater display FT2011-A1 and terminal FT2010-A Mimic display driver Batteries Spare parts Cover caps Printer rolls and typewriter ribbon Power supply Repair parts Operating units Operating add-ons Periphery boards Fire terminal board Fire brigade periphery module Network module (SAFEDLINK) Power supply Floor repeater terminal and floor repeater display Index

5 About this document 1 About this document Purpose This document describes all components, spare parts and repair parts for the FS20 fire detection system. This document is revised and expanded on a continuous basis. Scope This document contains information on all available components for market package 5.0. Target groups This document arranges itself to all persons. Reference documents Refer to the following documents for more information: FS20 Fire detection system Product data sheet FC2020 Fire control panel Product data sheet A6V FC2030 Fire control panel for migration Product data sheet FC2040 Fire control panel Product data sheet A6V FC2060 Fire control panel Product data sheet FT2040 Fire terminal Product data sheet FT2010-A1, FT2010-C1, FT2011-A1 Product data sheet Floor repeater terminal, floor repeater display A6V FT2001-A1 Mimic display driver, LED flat cable Product data sheet FS20 Fire detection system Technical description FS20 Fire detection system Characteristic product data FS20 Fire detection system Planning FS20 Fire detection system Installation FS20 Fire detection system Commissioning Fx20xx Fire control panel / Fire terminal Operation FT2010-A1, FT2010-C1, FT2011-A1 Floor repeater terminal, floor repeater display Operation Conventions (...) Additional information bold letters Definitions of designations see Cross-reference Document identification Place Signification Title page System names Product type Document purpose Last page bottom left Document number Version date 5

6 About this document Modification index Version Date Brief description _a_en_ Initial edition for field test _b_en_ Corrected version for release MP _c_en_ All new international MP1.2 components supplemented _d_en_ Modified STEP Link, New components Mimic display driver FT2001-A1, F50F410, License key (L2), minor changes _e_en_ New components as FT2010-C1, FC2030, FC2060, FCM2015- D1, FCL2001-A1, FCL2002-A1, FCL2003-A1, FCI2008-A1, DL3750+, Black typewriter ribbon for DL3750+, FA2009-A1, FTO2001-A1 as spare part deleted, changed name and part no. of spare part FP2004-A1, minor changes, _f_en_ Incorrect picture with FH2006-A1, in chapter housings FH2001-E1 and FH2001-G1 no longer available as alternate FCM2006-A1 and FCM2007-A _g_en_ Correction of color (~RAL) and address _h_en_ Standards and/or VdS added: FC2030-AA, FC2060-AA, FCA2005-A1. New graphic FN2001-A1. Housing FDCH221 added _i_en_ New graphic FA2009-A1 Panels for version 3.0: New Network components:fn2008-a1, FN2009-A1, FHA2029-A1, FHA2030-A _j_en_ Dimensions with cover cap (for all panels) FC2040-GA (Large) Corrections for MP4.0 FC2080 and components _k_en_ Wrong product denomination FCA2008-A1, New pictures FA200x-A1 and new dimensions _l_en_ New products: FCA2007-A1, FCC2008-D1, SV 24V-150W (V24230-Z6-A5) _m_en_ FCL2005, FCL2006, FCL2007, FCM2036-A2, FCM2038-A2, FCA2033-A1, FCA2034-A1, FCA2035-A1, FCA2036-A _o_en_ Content correction Download The current issue documentation and photos can be found in the Siemens Intranet. (STEP, Asset Portal) 6

7 2 Fire control panels 2.1 FC2020 fire control panels (2-loop) in housing (Standard) Fire control panels FC2020-AZ Fire control panel (2-loop) Part no. A5Q FC2020-EZ Fire control panel (2-loop) Part no. A5Q Expansion See chapter 2.7 Accessories See chapter 2.8 FC2020-AZ Product data sheet FC2020-EZ The FC2020 in housing (Standard) is a compact, prefabricated fire control panel with integrated operating unit capable of processing Sinteso TM device signals. The fire control panel may be used as a stand-alone unit or networked. Up to 32 fire control panels and fire terminals can be connected in a single cluster (FCnet/SAFEDLINK network), or up to 16 panels when the cluster is connected to a danger management system. Using a fiber-optic backbone (FCnet/LAN) up to 14 of these clusters with up to 16 panels each can be networked. This topology enables the construction of an EN 54-compliant network with up to 64 fire control panels and fire terminals. Connection of Siemens Danger Management System. Suitable for smaller applications, e.g. workshops, hotels, etc. Consists of: Housing (Standard) Operating unit Periphery board Power supply 70 W, emergency power supply (batteries must be ordered separately) With 24 indicator groups, with each one red and yellow LED Mains voltage AC V Power supply 70 W Operating voltage DC V Operating current max. 2.5 A Battery capacity 2 x 12 V, 7 12 Ah Connectable detector series Sinteso (FDnet) Number of lines 2 (4) loops or 4 (8) stub lines Number of addresses Max. 252 Relay output remote monitoring Alarm Fault 1 1 Monitored outputs Alarm Fault Horn Free programmable inputs/outputs 8 Operating temperature C Storage temperature C Humidity (no condensation permitted) 95 % Without cover cap With cover cap x 398 x 160 mm 430 x 398 x 188 mm Color Housing grey, ~RAL 7035 Cover white, ~RAL 9010 Protection category IP30 Standards EN 54-2, EN 54-4 Approvals VdS / LPCB G / 126bn/01 7

8 Fire control panels 2.2 FC2020 fire control panels (2-loop) in housing (Comfort) FC2020-AA Fire control panel (2-loop) Part no. A5Q FC2020-AE Fire control panel (2-loop) Part no. A5Q Expansion See chapter 2.7 Accessories See chapter 2.8 FC2020-AA Product data sheet The FC2020 in housing (Comfort) is a compact, prefabricated fire control panel with integrated operating unit capable of processing Sinteso device signals. The fire control panel may be used as a stand-alone unit or networked. Up to 32 fire control panels and fire terminals can be connected in a single cluster (FCnet/SAFEDLINK network), or up to 16 panels when the cluster is connected to a danger management system. Using a fiber-optic backbone (FCnet/LAN) up to 14 of these clusters with up to 16 panels each can be networked. This topology enables the construction of an EN 54-conform network with up to 64 fire control panels and fire terminals. Connection of Siemens Danger Management System. Suitable for smaller applications, e.g. shops, hotels, etc. Consists of: Housing (Comfort) Operating unit Periphery board Power supply 150 W, emergency power supply (batteries must be ordered separately) FC2020-AE With 48 indicator groups, with each one red and yellow LED Mains voltage AC 230 V Power supply 150 W Operating voltage DC V Operating current Max. 5 A Battery capacity 2 x 12 V, 7 26 Ah Connectable detector series Sinteso (FDnet) Number of lines 2 (4) loops or 4 (8) stub lines Number of addresses Max. 252 Relay output remote monitoring Alarm Fault 1 1 Monitored outputs Alarm Fault Horn Free programmable inputs/outputs 8 Operating temperature C Storage temperature C Humidity (no condensation permitted) 95 % rel. Without cover cap With cover cap 430 x 796 x 160 mm 430 x 796 x 188 mm Color Housing grey, ~RAL 7035 Cover white, ~RAL 9010 Protection category IP30 Standards EN54-2, EN54-4 Approvals VdS / LPCB G / 126bn/

9 2.3 FC2030 Fire control panel (Modular) for modernization Fire control panels FC2030-AA Fire control panel (Modular) Part no. S54400-C2-A1 Expansion See chapter 2.7 Accessories See chapter 2.8 Product data sheet A6V The FC2030 in housing (Comfort) is a modular prefabricated fire control panel with integrated operating unit for the migration of small existing older fire alarm systems. The control panel's basic equipment features a card cage for fitting a max. of 2 line cards are possible or 1 of each. The control panel processes signals from Sinteso, MS7/9/24, DS11, Synova 600, SIGMACON and MS9i devices. An integrated card cage with 2 slots allows: FCL2001-A1 line card /FDnet) 4 loops (with a total of max. 252 addresses) FCL2002-A1 line card collective (8 Lines) FCL2003-A1 line card MS9i (2 loops with a total of max. 100 addresses) FCL2005-A1 line card AnalogPLUS (4 per line card with a total of max. 512 addresses) FCL2006-A1 line card Interactive (1 per line card with a total of max. 128 addresses) FCL2007-A1 line card interactive-ex (1 per line card with a total of max. 32 addresses) FCI2008-A1 I/O card (with 12 freely programmable inputs/outputs per I/O card) FCI2009-A1 I/O card (with 8 monitored horn lines or monitored outputs) Mixed application all line- and I/O cards possible. The fire control panel may be used as a stand-alone unit or networked. Up to 32 fire control panels and fire terminals can be connected in a single cluster (FCnet/SAFEDLINK network), or up to 16 panels when the cluster is connected to a danger management system. Using a fiber-optic backbone (FCnet/LAN) up to 14 of these clusters with up to 16 panels each can be networked. This topology enables the construction of an EN 54-conform network with up to 64 fire control panels and fire terminals. Connection of Siemens Danger Management System. The FC2030 is designed for modernizing existing. It is suited to a gradual seamless transition from older systems to Sinteso. Consists of: Housing (Comfort) Operating unit Periphery board Card cage for use of max. 2 line cards Power supply 150 W, emergency power supply (batteries must be ordered separately) Mains voltage Power supply Operating voltage Operating current Battery capacity Connectable detector series Number of integrated lines (FDnet) Number of FDnet lines (additional line card FDnet) Number of collective lines Number of MS9i lines Number of AnalogPLUS lines Number of interactive lines Number of interactive-ex lines Number of addresses max. 756 Relay output remote monitoring Alarm / Fault 1 / 1 Monitored outputs Alarm / Fault / Horn 1 / 1 / 1 Free programmable inputs/outputs 8 Operating temperature C Storage temperature C AC 230 V 150 W DC 21 28,4 V max. 5 A 2 x 12 V, Ah Sinteso, MS7/9/24, MS9i, DS11, Synova 600, SIGMACON 2 (4) loops or 4 (8) stub lines max. 8 (4 per line card) max. 16 (8 per line card) max. 4 (2 per line card) max.8 (4 per line card) max. 2 (1 per line card) max. 2 (1 per line card) Humidity (no condensation permitted) 95 % rel. Without cover cap 430 x 796 x 160 mm With cover cap 430 x 796 x 188 mm Color Housing grey, ~RAL 7035 Cover white, ~RAL 9010 Protection category IP30 Standards EN54-2, EN54-4 Approvals VdS / LPCB G / 126bn/02 9

10 Fire control panels 2.4 FC2040 Fire control panels (4-loop) FC2040-AA Fire control panel (4-loop) Part no. A5Q FC2040-AE Fire control panel (4-loop) Part no. A5Q FC2040-AG Fire control panel (4-loop) Part no. A5Q FC2040-GA Fire control panel (4-loop) Part no. S54400-C3-A3 FC2040-AA, FC2040-GA (Large) Expansion See chapter 2.7 Accessories See chapter 2.8 Product data sheet The FC2040 is a compact, prefabricated fire control panel with integrated operating unit capable of processing Sinteso device signals. The fire control panel may be used as a stand-alone unit or networked. Up to 32 fire control panels and fire terminals can be connected in a single cluster (FCnet/SAFEDLINK network), or up to 16 panels when the cluster is connected to a danger management system. Using a fiber-optic backbone (FCnet/LAN) up to 14 of these clusters with up to 16 panels each can be networked. This topology enables the construction of an EN 54-conform network with up to 64 fire control panels and fire terminals. Connection of Siemens Danger Management System. Ideally suited for mid-size applications, e.g. industrial facilities, regional banks, office complexes, etc. The FC2040 can be used by the flexible cross-linking possibilities however also for extensive systems. FC2040-AE Consists of: Housing (Comfort) or (Large) Operating unit Periphery board Power supply 150 W, emergency power supply (batteries must be ordered separately) With 48 indicator groups, with each one red and yellow LED FC2040-AG Mains voltage AC 230 V Power supply 150 W Operating voltage DC V Operating current Max. 5 A Battery capacity 2 x 12 V, Ah Connectable detector series Sinteso (FDnet) Number of lines 4 (8) loops or 8 (16) stub lines Number of addresses Max. 504 Relay output remote monitoring Alarm 1 Fault 1 Monitored outputs Alarm Fault Horn Free programmable inputs/outputs 12 Operating temperature C Storage temperature C Humidity (no condensation permitted) 95 % rel. Comfort (FC2040-AA) Alarm 430 x 796 x 160 mm Fault 430 x 796 x 188 mm Color Housing grey, ~RAL 7035 Cover white, ~RAL 9010 Protection category IP30 Standards EN54-2, EN54-4 Approvals VdS / LPCB G / 126bn/ Large (FC2040-GA) 430 x 796 x 260 mm 430 x 796 x 288 mm With 96 indicator groups, with each one red and yellow LED 10

11 2.5 FC2060 Fire control panel for modernisation Fire control panels FC2060-AA Fire control panel (Modular) Part no. A5Q Expansion See chapter 2.7 Accessories See chapter 2.8 Product data sheet A6V The FC2060 is a modular fire control panel with integrated operating unit for large installations and for modernizing large older fire detection installations. The control panel's basic equipment features a card cage for fitting of additional line- or I/O cards. An integrated card cage with 5 slots allows: FCL2001-A1 line card /FDnet) 4 loops (with a total of max. 252 addresses) FCL2002-A1 line card collective (8 Lines) FCL2003-A1 line card MS9i (2 loops with a total of max. 100 addresses) FCL2005-A1 line card AnalogPLUS (4 per line card with a total of max. 512 addresses) FCL2006-A1 line card Interactive (1 per line card with a total of max. 128addresses) FCL2007-A1 line card interactive-ex (1 per line card with a total of max. 32 addresses) FCI2008-A1 I/O card (with 12 freely programmable inputs/outputs per I/O card) FCI2009-A1 I/O card (8 monitored horn lines or monitored outputs) Mixed application all line- and I/O cards possible. The fire control panel may be used as a stand-alone unit or networked. Up to 32 fire control panels and fire terminals can be connected in a single cluster (FCnet/SAFEDLINK network), or up to 16 panels when the cluster is connected to a danger management system. Using a fiber-optic backbone (FCnet/LAN) up to 14 of these clusters with up to 16 panels each can be networked. This topology enables the construction of an EN 54-conform network with up to 64 fire control panels and fire terminals. The FC2060 is ideally suited to large applications, e.g. for industrial plants, office complexes, chemicals, manufacturing etc. During modernization, it is also suited to a gradual seamless transition from older systems to Sinteso. Consists of: Housing (Comfort) Operating unit Periphery board Card cage for use of max. 5 line cards (FDnet, collective, MS9i) and/or I/O cards Power supply 150 W, emergency power supply (batteries must be ordered separately) Mains voltage Power supply Operating voltage Operating current Battery capacity Connectable detector series Number of FDnet lines (integrated) Number of FDnet lines (additional line card FDnet) Number of collective lines (line card collective) Number of MS9i lines (line card MS9i) Number of AnalogPLUS lines Number of Interactive lines Number of Interactive-Ex lines Number of addresses max Integrated inputs/outputs Relay output Remote transmission alarm Remote transmission fault Monitored outputs Alarm / Fault / Horn Free programmable inputs/outputs 1 / 1 / 2 12 Operating temperature C Storage temperature C Humidity (no condensation permitted) 95 % rel. Without cover cap With cover cap AC 230 V 150 W DC V max. 5 A 2 x 12 V, 7 45 Ah Sinteso, MS7/9/24, MS9i, DS11, Synova 600, SIGMACON 4 (8) loops or 8 (16) stub lines max. 20 (4 per line card) max. 40 (8 per line card) max. 10 (2 per line card) max. 20 (4 per line card) max. 5 (1 per line card) max. 5 ( 1 per line card) x 796 x 260 mm 430 x 796 x 288 mm Color Housing grey, ~RAL 7035 Cover white, ~RAL 9010 Protection category Standards Approvals VdS / LPCB IP30 EN54-2, EN54-4 G / 126bn/04 11

12 Fire control panels 2.6 FC2080 Fire control panel (Modular) FH2080-AA Fire control panel (Modular) Part no. S54400-C103-A1 Expansion See chapter 2.7 Accessories See chapter 2.8 Product data sheet A6V The FC2080 is a modular fire control panel for large and challenging sites. With redundant main processor as an option. Installation occurs in a 19" free-standing cabinet. Can be extended through the use of up to 37 module bus cards in max. 7 card cages and processes up to 5000 addresses. The FC2080 processes signals from various detector systems such as: MS7/9/24, DS11, Synova 600, SIGMACON and addressable fire detectors of the MS9i, AnalogPLUS and Interactive series It is possible to connect a total of 37 module bus cards: FCL2001-A1 line card /FDnet) 4 loops (with a total of max. 252 addresses) FCL2002-A1 line card collective (8 Lines) FCL2003-A1 line card MS9i (2 loops with a total of max. 100 addresses) FCL2005-A1 line card AnalogPLUS (4 per line card with a total of max. 512addresses) FCL2006-A1 line card Interactive (1 per line card with a total of max. 128 addresses) FCL2007-A1 line card interactive-ex (1 per line card with a total of max. 32 addresses) FCI2008-A1 I/O card (with 12 freely programmable inputs/outputs per I/O card) FCI2009-A1 I/O card (8 monitored horn lines or monitored outputs) FCI2007-A1 I/O card (Alarm, fault, local alarm) Mixed application all line- and I/O cards possible. The fire control panel may be used as a stand-alone unit or networked. Up to 32 fire control panels and fire terminals can be connected in a single cluster (FCnet/SAFEDLINK network), or up to 16 panels when the cluster is connected to a danger management system. Using a fiber-optic backbone (FCnet/LAN) up to 14 of these clusters with up to 16 panels each can be networked. This topology enables the construction of an EN 54-conform network with up to 64 fire control panels and fire terminals. Fire terminal and LED display groups shall be ordered separately. Mains voltage AC 230 V Power supply >150 W Operating voltage DC V Operating current (per electric circuit) > 3 A Battery capacity (per electric circuit) 2 x 12 V, max. 100 Ah Battery monitoring / mains monitoring yes / yes Connectable detector series Sinteso, MS7/9/24, DS11, Synova 600, SIGMACON Number of FDnet lines Max. 120 (4 per line card) Number of collective lines (line card collective) Max. 240 (8 per line card) Number of MS9i lines (line card MS9i) Max. 60 (2 per line card) Number of AnalogPLUS lines (line card AnalogPLUS) Max. 120 (4 per line card) Number of Interactive lines (line card Interactive) Max. 30 (1 per line card) Number of Interactive-Ex lines (line card Interactive-Ex) Max. 30 (1 per line card) Number of addresses Max Input / output cards I/Os programmable 12 (per FCI2008-A1) I/Os (horn) 8 (per FCI2009-A1) I/Os (RT) RT alarm (monitored and relay) RT fault (monitored and relay) Local alarm (per FCI2007-A1) (per FCI2007-A1) 1 Slots for line cards or I/O cards Max. 37 Serial interfaces RS232, RS (integrated) Ethernet interfaces 1 Slots for network modules (on CPU and COM cards) 1 (per FCI2004-A1) 1 (per FCI2005-A1) Operating temperature C Storage temperature C Humidity (no condensation permitted) 95 % rel. Free-standing cabinet (incl. base) 600 x 2200 x 600 mm Color grey, ~RAL 7035 Protection category IP30 Standards EN54-2, EN54-4, VDS 2095 Approval VdS G

13 2.7 Control panel expansion Fire control panels License key FCA2033-A1 License key (S1) Part no. S54400-P154-A1 FCA2034-A1 License key (S2) Part no. S54400-P155-A1 FCA2035-A1 License key (S3) Part no. S54400-P156-A1 FCA2036-A1 License key (S4) Part no. S54400-P174-A1 - One license key per control unit is applicable only. - For the release of optional functions Event printer FTO2001-A1 Event printer Part no. A5Q The event printer can be used in all FC20 control panels, FT2040 Terminals or in all empty housings if space is available. including interface cable, power supply and paper roll Function The event printer is a thermal printer that logs alarms, faults and all messages. The RS232 module FCA2001-A1 is required to operate the printer. The RS232 module must be ordered separately Mounting plate Operating voltage DC 9 48 V Operating current Quiescent at DC 9 V at DC 48 V 50 ma 3 A 0.7 A Interface RS232 serial Operating temperature C Storage temperature C Humidity (no condensation permitted) 95 % rel. 85 x 85 x 55 mm FHA2007-A1 Mounting plate Part no. A5Q Features The mounting plate can pivot allowing access to the underlying module. E.g. to mount the fire brigade periphery module or the sounder modules. Screwed on to the back wall of the housings (Standard, Comfort and Large). 221 x 241 x 46 mm 13

14 Fire control panels Fire brigade periphery module FCI2001-D1 Fire brigade periphery module Part no. A5Q Sounder module For VdS compliant switching to fire department periphery devices (for Germany). Features The module has connections for FBF, FSD, ÜE, FSE, ÖA, KL, tamper alarm FSD. Mounted in the housing (Standard and Large) on the mounting plate FHA2007-A1, in housing (Comfort) on the back wall of the housing or on the mounting plate. Operating voltage DC V Operating current Max. 1.6 A Connection terminals VdS peripheral devices mm 2 Connection terminals for power supply mm x 190 x 40 mm FCA2005-A1 Sounder module Part no. A5Q With the sounder module it's possible to split up a collective horn line on 4 lines. Each of this line controls and monitored each individual sounder. 2 sounder modules can be used, but condition is a cascading of both. The sounder module can be mounted onto the mounting plate FHA2007-A1 or onto the U-rail TS35 in control panel with the enclosed mounting feeds. 2 mounting feeds Operating voltage DC V Operating current Max. 2 A (fused with 2 AT) Quiescent current 20 ma Supervised output 4 x 1 A Cable capacity mm 2 Humidity 95 % rel. rel. Color housing / cover white, ~RAL 9010 / transparent matt 132 x 90 x 24 mm Standard EN54-18 Approval VdS G Network module (SAFEDLINK) FN2001-A1 Network module (SAFEDLINK) Part no. A5Q To network multiple stations FCnet/SAFEDLINK. Plugged into the back side of the operating unit. Connection terminals mm 2 50 x 20 x 70 mm 14

15 Fire control panels Repeater (SAFEDLINK) FN2002-A1 Repeater (SAFEDLINK) Part no. S24236-B2502-A1 The module is a repeater in the FCnet. It is used for the extension of the range of the system bus FCnet. Between 2 stations max. 1 repeater can be used. The distance between network module and repeater may be max m. The repeater can be mount directly on a plane surface, onto a U-rail TS35 with the enclosed mounting feeds or in a housing FDH291/ mounting feeds Communication protocol SAFEDLINK (UDP/IP) Operating voltage DC V Operating current Max. 45 ma Connection terminals mm 2 Humidity 95 % rel. rel. Color housing / cover white, ~RAL 9010 / transparent matt Protection category EN60529/IEC529 IP30 with aux. housing FDCH291 IP54 with aux. housing FDCH292 IP x 90 x 24 mm Accessories for Repeater U-rail TS35, L=122 mm Part no. BPZ: U-rail TS35, L=288 mm Part no. BPZ: For the series mounting of in-/output modules, repeater together with the mounting feeds. FDCH221 Housing for in-/output modules Part no. S54312-F3-A1 For the mounting of the in-/output modules, repeater for dirty, dry applications. Protection category EN60529/IEC529 Color housing / cover Dimensions IP54 white, ~RAL 9010 / transparent matt 207 x 119 x 48 mm 15

16 Fire control panels Metal screwed cable gland M20 x 1.5 Part no. A5Q Back nut Part no. A5Q For surface-mounted feed lines. Cable gland Dimensions M20 x 1.5 Back nut Dimensions M RS485 module FCA2002-A1 RS485 module (isolated) Part no. A5Q For periphery devices with RS485 interface, e.g. for FAT (GER). Plugged into the back side of the operating unit. Connection terminals mm 2 50 x 15 x 70 mm RS232 module FCA2001-A1 RS232 module (isolated) Part no. A5Q For periphery devices with RS232 interface, e.g. for event printer FTO2001-A1 or for external matrix printer DL Plugged into the back side of the operating unit FCC2004-A1 Connection terminals mm 2 50 x 15 x 70 mm FCC2004-A1 CPU card (FC2080) Part no. S54400-A18-A1 For integrating periphery devices and integration with other systems. Plugged into the card cage Connection terminals mm 2 50 x 15 x 70 mm 16

17 Fire control panels FCC2005-A1 FCC2005-A1 Communication card (FC2080) Part no. S54400-A91-A1 For integrating periphery devices and integration with other systems. Plugged into the card cage Connection terminals mm 2 50 x 15 x 70 mm FCC2008-D1 FCC2008-D1 Communication card (FG2020) Part no. S54400-A98-A1 Communication card for the FG2020. Plugged into the card cage Connection terminals mm 2 50 x 15 x 70 mm FCA2007-A1 FCA2007-A1 Card cage (2 slots) Part no. S54400-B38-A1 Enables use of max. 2 module bus cards in any combination Connection terminals mm FCA2008-A1 FCA2008-A1 Card cage (5 slots) Part no. S54400-B28-A1 Enables use of max. 5 module bus cards in any combination Connection terminals mm 2 17

18 Fire control panels Loop extension (FDnet) FCI2003-A1 Loop extension (FDnet) Part no. A5Q With the loop extension, the number of connectable loops is doubled from 2 to 4. The number of FDnet addresses per station remains unchanged. For each integrated line one loop extension can be equipped. Plugged onto the periphery board of the control panel. Number of detector lines 2 loops or 4 stub lines Connection terminals mm 2 48 x 20 x 70 mm Line card (FDnet) FCL2001-A1 Line card (FDnet) Part no. A5Q The FDnet line card is an additional card to the integrated FDnet lines. It is used to expand FC2030, FC2060 and FC2080 with additional FDnet lines. Additionally, it can be applied when modernizing legacy detector lines to Sinteso. In this case, the legacy line card can simply be replaced by the FDnet line card. All FDnet devices can be connected to the line card. Is mounted in card cage of FC2030 (2 slots) and of FC2060 / FC2080 (5 slots) fire control panels. Input current max. 0.8 A Number of detector lines 4 loops or 8 stub lines Number of addresses max Line card (collective) FCL2002-A1 Line card (collective) Part no. A5Q The collective line card is an additional line card for fire detectors with collective signal evaluation. All detectors within a line have the same address. The line card is required for step by step migration from collective detectors to Sinteso FDnet devices. The line card is designed for 8 collective stub lines each with up to 32 detectors for all collective detectors from series Sinteso, MS7/9/24, DS11, Synova 600, SIGMACON. èline termination for MS7/9/24, DS11, SynoLINE600 -> EOL22(Ex), 4k7, 3k3. èline termination for MS24, DS11, SynoLINE600 -> EOL22(Ex), Transzorb (20 V). Is mounted in card cage of FC2030 (2 slots) and of FC2060 / FC2080 (5 slots) fire control panels. Input current max. 0.6 A Output current max. 0.6 A per line Number of detector lines 8 18

19 Fire control panels Accessories line card (collective) EOL22(Ex) Line termination Part no. BPZ: End-of-line unit for collective detection lines or as end-of-line unit within explosion-hazard areas of zones 1 and 2. Transzorb diode P6KE20CA bi-directional 20 V, 5 %, 600 W/ms Part no. BPZ: End of line unit for collective detection lines Line card (MS9i) FCL2003-A1 Line card (MS9i) Part no. A5Q The MS9i line card is an additional card for MS9i fire detectors with addressable signal evaluation. The line card is required for step by step migration of MS9i detectors to Sinteso FDnet devices. The line card it designed for 2 loops per card. Is mounted in card cage of FC2030 (2 slots) and of FC2060 / FC2080 (5 slots) fire control panels. Output current max. 0.5 A per card Number of detector lines 2 loops Number of addresses max Line card (AnalogPLUS) -A1 Line card (AnalogPLUS) Part no. S54400-A107-A1 The AnalogPLUS line card is an additional card for AnalogPLUS fire detectors with addressable signal evaluation. The line card is required for step by step migration of AnalogPLUS detectors to Sinteso FDnet devices. The line card is designed for 4 loops per card. Is mounted in card cage of FC2030 (2 slots) and of FC2060 / FC2080 (5 slots) fire control panels. Output current max. 0.5 A per card Number of detector lines 4 loops Number of addresses max

20 Fire control panels Line card (Interactive) FCL2006-A1 Line card (Interactive) Part no. S54400-A108-A1 The Interactive line card is an additional card for Interactive fire detectors with addressable signal evaluation. The line card is required for step by step migration of Interactive detectors to Sinteso FDnet devices. The line card is designed for 1 loop per card. Is mounted in card cage of FC2030 (2 slots) and of FC2060 / FC2080 (5 slots) fire control panels. Output current max. 0.5 A per card Number of detector lines 1 loop Number of addresses max Line card (Interactive-Ex) FCL2007-A1 Line card (Interactive-Ex) Part no. S54400-A134-A1 The Interactive-Ex line card is an additional card for Interactive-Ex fire detectors with addressable signal evaluation. The line card is required for step by step migration of Interactive-Ex detectors to Sinteso FDnet-Ex devices. The line card is designed for 1 loop per card. Is mounted in card cage of FC2030 (2 slots) and of FC2060 / FC2080 (5 slots) fire control panels. Output current max. 0.5 A per card Number of detector lines 1 loop Number of addresses max I/O card (programmable) FCI2008-A1 I/O card (programmable) Part no. S54400-A6-A1 The I/O card is an additional card with programmable inputs and outputs for expansion of the integrated inputs and outputs. Is mounted in card cage of FC2030 (2 slots) and of FC2060/FC2080 (5 slots) fire control panel. Input current max. 2 A Programmable inputs/outputs 12 20

21 Fire control panels Network components FN2008-A1 Ethernet switch Part no. S54400-F94-A1 The Ethernet switch connects individual clusters via the Ethernet backbone. A second switch can be added if a cluster has more than 512 detectors. With a mounting kit (FHA2029-A1 or FHA2030-A1), the Ethernet switch can be easily integrated into panels or additional housings. FN2006-A1 Fiber network module (SM) Bestell-Nr. S54400-A61-A1 With the fiber optic cable network module Single Mode (SM), FS20 stations can be networked over great distances by means of glass fiber optic cables using the system bus FCnet/SAFEDLINK. The single mode transmission goes up to 40 km FN2007-A1 Fiber network module (MM) Bestell-Nr. S54400-A62-A1 With the fiber optic cable network module Multi Mode (MM), FS20 stations can be networked over great distances by means of glass fiber optic cables using the system bus FCnet/SAFEDLINK. The multi mode transmission goes up to 4 km 21

22 Fire control panels FHA2029-A1 Mounting kit Part no. S54400-B79-A1 Mounting kit for FN2008-A1 Ethernet switch in housing (Comfort) FHA2030-A1 Mounting kit Part no. S54400-B81-A1 Mounting kit for FN2008-A1 Ethernet switch in housing (Large) 22

23 Fire control panels Housing Standard and Large Extension (empty) FH2002-A1 Housing (Standard) Part no. A5Q FH2007-A1 Housing (Std. +plan comp.) Part no. A5Q FH2004-A1 Housing (Large Extension) Part no. A5Q FH2002-A1 FH2002-A1 Empty housing for open application, e.g. additional batteries, for operating add-ons or for the event printer. Space for batteries -> 2 x FA2003-A1 (7 Ah) or 2 x FA2004-A1 (12 Ah) FH2007-A1 Empty housing for documents A4, depth 150 mm. FH2007-A1 FH2004-A1 Empty housing for larger batteries. Space for larger batteries -> 2 x FA2007-A1 (45 Ah) or 2 x FA2008-A1 (65 Ah) Space for aux. power supply -> FP2004-A1 Power supply kit (150 W, A) or FP2005-A1 Power supply kit (150 W, B) FH2004-A1 FH2002-A1 430 x 398 x 160 mm FH2007-A1 430 x 398 x 160 mm FH2004-A1 430 x 398 x 260 mm Color Housing grey, ~RAL 7035 Cover white, ~RAL 9010 Protection category IP30 23

24 Fire control panels Housing Comfort and Large (empty) FH2003-A1 Housing (Comfort) Part no. A5Q FH2005-A1 Housing (Large) Part no. A5Q FH2003-A1 FH2003-A1 Empty housing for open application, e.g. additional batteries, for operating add-ons or for the event printer. Space for batteries -> 2 x FA2003-A1 (7 Ah) or 2 x FA2004-A1 (12 Ah) or 2 x FA2005-A1 (17 Ah) or 2 x FA2006-A1 (26 Ah) FH2005-A1 Empty housing for larger batteries. Space for larger batteries -> 4 x FA2006-A1 (26 Ah) or 4 x FA2007-A1 (45 Ah) or 2 x FA2008-A1 (65 Ah) Space for aux. power supply -> FP2004-A1 Power supply kit (150 W, A) or FP2005-A1 Power supply kit (150 W, B) FH2005-A1 FH2003-A1 430 x 796x 160 mm FH2005-A1 430 x 796 x 260 mm Color Housing grey, ~RAL 7035 Cover white, ~RAL 9010 Protection category IP Operating add-ons FCM2038-A2 Operating add-on (2xLED ind.) Part no. S54400-B146-A1 To update 48 LED display groups, with one red/green and yellow LED each. Can be inserted in all available housings. 427 x 200 x 25 mm FCM2036-A2 Operating add-on (4xLED ind.) Part no. S54400-B147-A1 To update 96 LED display groups, with one red/green and yellow LED each. Can be inserted in all available housings. 427 x 200 x 25 mm 24

25 Fire control panels Operating units FCM2028-A2 Operating unit Part no. S54400-F83-A1 FCM2028-F2 Operating unit (FR only) Part no. S54400-F83-A3 For retrofitting Can be inserted in all available housings. 427 x 200 x 25 mm FCM2029-A2 Operating unit (+LED ind.) Part no. S54400-F84-A1 For retrofitting Can be inserted in all available housings. 427 x 200 x 25 mm FCM2030-C2 Operating unit (+FBA terminal), CH only Part no. S54400-F93-A1 For retrofitting Can be inserted in all available housings. 427 x 200 x 25 mm FCM2030-N2 Operating unit (+EVAC terminal), NL only Part no. S54400-F93-A2 For retrofitting Can be inserted in all available housings. 427 x 200 x 25 mm 25

26 Fire control panels Auxiliary power supply FP2003-A1 Power supply kit (70 W) Part no. A5Q Auxiliary power supply to all stations (control panels and terminals). Function Converts mains voltage to system voltage. Monitors mains voltage and batteries. Mains voltage Current Power consumption AC V A Max. 90 VA 95 x 170 x 54 mm FP2004-A1 Power supply kit (150 W, A) Part no. A5Q FP2005-A1 Power supply kit (150 W, B) Part no. A5Q Power supply kit (150 W, A) as auxiliary power supply for installation into empty housing. Power supply kit (150 W, B) as auxiliary power supply for cascading. Function Converts mains voltage to system voltage. Monitors mains voltage and batteries. Mains voltage Current Power consumption AC 230 V 1.2 A Max. 300 VA 130 x 150 x 70 mm 26

27 2.8 Accessories for control panels Fire control panels Key switches FTO2005-C1 Key switch (Kaba) Part no. A5Q FTO2006-B1 Key switch (nordic) Part no. A5Q FTO2005-C1 Features Kaba or Nordic key switch with mounting accessories and key as an option for operating access (operating unit). FTO2006-B1 Lock Key Kaba, Nordic Kaba 8 #100, Nordic Relay module Z3B171 Relay module 250 VAC, 10 A Part no. BPZ: To connect fire control, e.g. fire doors, fans, elevators, etc. 1 changeover contact AC 250 V/ 10 A Is mounted on existing DIN rail TS x 50 x 15 mm 27

28 Fire control panels " mounting kit FHA2016-A1 19" mounting kit Part no. A5Q To install fire control panels and fire terminals in a 19" third-party housing. 430 x 100 x 324 mm Carrier 19" FHA2021-A1 Battery tray (19") Part no. S54400-B23-A1 For holding batteries in the 19 cabinet (FC2080). mm FHA2022-A1 Carrier (19", power supply) Part no. S54400-B24-A1 For the 19 installation incl. 2 x 150W (FC2080). mm FHA2023-A1 Carrier (19", card cage) Part no. S54400-B25-A1 For installing the card cage in the 19" cabinet (FC2080). mm FHA2024-A1 Carrier (19", options) Part no. S54400-B26-A1 For installing options in the 19" cabinet (FC2080). mm 28

29 Fire control panels Cable kit (communication) FCA2014-A1 Cable kit (communication) Part no. A5Q For flexible cable connections to the modules on the PMI-& main board FM-blinds FHA2017-A1 FM-blind 1HU Part no. A5Q FM-blind for recess mounting of fire control panels, fire terminals and empty housings (Standard and ECO). Color white, ~RAL 9010 Dimension (W x H) 530 x 500 mm FHA2015-A1 FM-blind 2HU Part no. A5Q FM-blind for recess mounting of fire control panels and empty housings (Comfort). Color white, ~RAL 9010 Dimension (W x H) 530 x 886 mm 29

30 Fire control panels Matrix printer (Extern) DL3750+ Matrix printer (Extern) Part no. A5Q The Fujitsu DL3750+ is a compact, noiseless A4 matrix printer. It is used for documenting relevant information in a system on continuous paper. The printer is constantly supervised by the fire control panel. The type of events to be printed is configurable. It offers a maximum of speed and reliability. The RS232 module FCA2001-A1 is required to operate the printer. The RS232 module must be ordered separately. Interface RS232 serial Resolution 360 x 360 dpi Character set 6 Number of copies 5 incl. original Operating temperature C Storage temperature C Humidity (no condensation) 95 % rel. 415 x 120 x 330 mm 30

31 3 Fire terminals 3.1 FT2040 fire terminals in housing (Eco) Fire terminals FT2040-AZ Fire terminal Part no. A5Q Expansion See chapter 0 Accessories See chapter 3.3 FT2040-AZ Product data sheet The fire terminal is an operating panel remote from the control unit. Up to 32 fire control panels and fire terminals can be connected in a single cluster (FCnet/SAFEDLINK network), or up to 16 panels when the cluster is connected to a danger management system. Using a fiber-optic backbone (FCnet/LAN) up to 14 of these clusters with up to 16 panels each can be networked. This topology enables the construction of an EN 54-conform network with up to 64 fire control panels and fire terminals. Connection of Siemens Danger Management System Consists of: Housing (Eco) Operating unit Fire terminal board Place for optional power supply 70 W, emergency power supply (batteries (7 Ah) must be ordered separately) Operating voltage DC V Current consumption at 24 V Quiescent current (illumination of the LCD inactive) 125 ma Alarm current (illumination of the LCD active) 130 ma Operating temperature C Storage temperature C Humidity (no condensation permitted) 95 % rel. Without cover cap With cover cap 430 x 398 x 80 mm 430 x 398 x 108 mm Color Housing grey, ~RAL 7035 Cover white, ~RAL 9010 Protection category IP30 Approvals VdS / LPCB G / 126bn/R01 31

32 Fire terminals 3.2 Fire terminal expansion License key FCA2033-A1 License key (S1) Part no. S54400-P154-A1 FCA2034-A1 License key (S2) Part no. S54400-P155-A1 FCA2035-A1 License key (S3) Part no. S54400-P156-A1 FCA2036-A1 License key (S4) Part no. S54400-P174-A1 See chapter for details Event printer FTO2001-A1 Event printer Part no. A5Q See chapter for details Network module (SAFEDLINK) FN2001-A1 Network module (SAFEDLINK) Part no. A5Q See chapter for details RS485 module FCA2002-A1 RS485 module (isolated) Part no. A5Q See chapter for details 32

33 Fire terminals RS232 module FCA2001-A1 RS232 module (isolated) Part no. A5Q See chapter for details Network components FN2008-A1 Ethernet switch) Part no. S54400-F94-A1 The Ethernet switch connects individual clusters via the Ethernet backbone. A second switch can be added if a cluster has more than 512 detectors. With a mounting kit (FHA2029-A1 or FHA2030-A1), the Ethernet switch can be easily integrated into panels or additional housings. FN2006-A1 Fiber network module (SM) Bestell-Nr. S54400-A61-A1 With the fiber optic cable network module Single Mode (SM), FS20 stations can be networked over great distances by means of glass fiber optic cables using the system bus FCnet/SAFEDLINK. The single mode transmission goes up to 40 km FN2007-A1 Fiber network module (MM) Bestell-Nr. S54400-A62-A1 With the fiber optic cable network module Multi Mode (MM), FS20 stations can be networked over great distances by means of glass fiber optic cables using the system bus FCnet/SAFEDLINK. The multi mode transmission goes up to 4 km 33

34 Fire terminals FHA2029-A1 Mounting kit Part no. S54400-B79-A1 Mounting kit for FN2008-A1 Ethernet switch in housing (Comfort) FHA2030-A1 Mounting kit Part no. S54400-B81-A1 Mounting kit for FN2008-A1 Ethernet switch (Large) Power supply kit (70 W) FP2003-A1 Power supply kit (70 W) Part no. A5Q See chapter for details Housings (Eco) FH2001-A1 Housing (Eco) Part no. A5Q FH2006-A1 Housing (Eco +plan comp.) Part no. A5Q FH2001-A1 FH2001-A1 Empty housing for open use, e.g. additional batteries, power supply, event printer or mimic displays. FH2006-A1 Empty housing for documents A4, depth 50 mm. FH2006-A1 430 x 398 x 80 mm Color Housing grey, ~RAL 7035 Cover white, ~RAL 9010 Protection category IP30 34

35 Fire terminals Operating add-ons FCM2038-A2 Operating add-on (2xLED ind.) Part no. S54400-B146-A1 To update 48 LED display groups, with one red and yellow LED each. Can be inserted in all available housings. 427 x 200 x 25 mm FCM2036-A2 Operating add-on (4xLED ind.) Part no. S54400-B147-A1 To update 96 LED display groups, with one red and yellow LED each. Can be inserted in all available housings. 427 x 200 x 25 mm 35

36 Fire terminals 3.3 Fire terminal accessories Key switch FTO2005-C1 Key switch (Kaba) Part no. A5Q FTO2006-B1 Key switch (Nordic) Part no. A5Q See chapter for details " mounting kit FHA2016-A1 19" mounting kit Part no. A5Q See chapter for details. 36

37 Fire terminals Cable kit (communication) FCA2014-A1 Cable kit (communication) Part no. A5Q See chapter for details FM-blind 1HU FHA2017-A1 FM-blind 1HU Part no. A5Q See chapter for details. 3.4 Floor repeater display and floor repeater terminal Floor repeater terminals FT2010-A1 Floor repeater terminal Part no. A5Q Product data sheet Small display and operating panel for floors. The floor repeater terminal is an FDnet device and can be operated in loops or stub lines. Features Display of alarms, pre-alarms, technical messages, faults, isolations possible Acknowledge and reset events Event text identical to the FC20xx fire control panel or FT2040 fire terminal Operating access with key The key switch (Nordic) may be replaced by key switch (Kaba) Power supply via FDnet, separate 24 V power supply possible Operating voltage DC V External supply input DC V / AC V Current consumption at 24 V Quiescent current (LCD lighting inactive) Maximum current (LCD lighting active) 5 ma 45 ma LCD illumination white 6 x 40 characters Key switch for operating access Nordic (optional Kaba) Operating temperature C Storage temperature C Humidity (no condensation permitted) 95 % rel. Communication protocol FDnet Connection terminals mm 2 Protection category IP30 Color grey, ~RAL x 207 x 79 mm Approvals VdS / LPCB G / pending 37

38 Fire terminals FT2010-C1 Floor repeater terminal Part no. S54400-F34-A1 Product data sheet Small display and operating panel for floors. The floor repeater terminal is an FDnet device and can be operated in loops or stub lines. Features Display of alarms, pre-alarms, technical messages, faults, isolations possible Acknowledge and reset events Event text identical to the FC20xx fire control panel or FT2040 fire terminal Operating access with key With key switch Kaba and flat rear (sheet metal) Power supply via FDnet, separate 24 V power supply possible Floor repeater display Operating voltage DC V External supply input DC V / AC V Current consumption at 24 V Quiescent current (LCD lighting inactive) Maximum current (LCD lighting active) 5 ma 45 ma LCD illumination white 6 x 40 characters Key switch for operating access Kaba Operating temperature C Storage temperature C Humidity (no condensation permitted) 95 % rel. Communication protocol FDnet Connection terminals mm 2 Protection category IP30 Color grey, ~RAL x 207 x 46 mm Approvals VdS / LPCB G / pending FT2011-A1 Floor repeater display Part no. A5Q Product data sheet Small display panel for floors. The floor repeater display is an FDnet device and can be operated in loops or stub lines. Features Display of alarms, pre-alarms, technical messages, faults, isolations possible Event text identical to the FC20xx fire control panel or FT2040 fire terminal Buzzer can be switched off for alarm messages Power supply via FDnet, separate 24 V power supply possible Operating voltage DC V External supply input DC V / AC V Current consumption at 24 V Quiescent current (LCD lighting inactive) Maximum current (LCD lighting active) 5 ma 45 ma LCD illumination white 6 x 40 characters Operating temperature C Storage temperature C Humidity (no condensation permitted) 95 % rel. Communication protocol FDnet Connection terminals mm 2 Protection category IP30 Color grey, ~RAL x 207 x 79 mm Approvals VdS / LPCB G / pending 38

39 Fire terminals Accessory for floor repeater terminal FT2010-A1 FTO2005-C1 Key switch (Kaba) Part no. A5Q See chapter for details Accessory for floor repeater display FT2011-A1 and terminal FT2010-A1 FHA2013-A1 Rear (FT201x flat) Part no. A5Q Flat rear when really flat installation is required and the cable is flush mounted. In place of the rear supplied with the floor repeater terminal or floor repeater display. Material Zinc-plated sheet metal 271 x 191 x 27.5 mm 39

40 Fire terminals 3.5 Mimic display driver FT2001-A1 Mimic display driver Part no. A5Q Product data sheet A6V The FT2001-A1 has 2x24 outputs for LED activation for mimic display panels. The mimic display driver is an FDnet device and can be operated in loops or stub lines. Features 2 control outputs for 'Local buzzer' and 'LED operation' 2 inputs for 'Switch-off buzzer' and 'Lamp test' integrated line separator Power supply via FDnet, separate 24 V power supply possible Connection to LED via flat cable F50F410 (50-wire, 24 red LEDs, cable length 1 m, must be ordered separately). Operating voltage Operating current Quiescent current External supply input Outputs 'Operating LED' 'Local buzzer' DC V max. 45 ma max. 5 ma DC V, galvanically isolated AC V, galvanically isolated" max. 2.5 ma and DC 2.5 V max. 5 ma and DC 12 V Operating temperature C Storage temperature C Humidity 95 % rel. Communication protocol FDnet Connection terminals mm 2 Protection category IP30 (3rd party housing) 106 x 200 x 45 mm Approvals VdS / LPCB VdS G / pending F50F410 LED flat cable 50-wire, with 24 red LEDs Part no. BPZ: Two F50F410 LED cables can be connected directly to the mimic display driver to offer a total of 48 (2x24) red LEDs. Features The LEDs can be easily configured via the configuration tool. Cable length LED 1 m 24 (red) 40

41 4 Batteries Batteries FA2003-A1 Battery (12 V, 7 Ah, VDS) Part no. A5Q Features Rechargeable sealed lead-acid battery for emergency power supply. Must be ordered 2 batteries (system voltage 24 V). Dimensions max. (W x H x D) 153 x 103 x 67 mm FA2004-A1 Battery (12 V, 12 Ah, VDS) Part no. A5Q Features Rechargeable sealed lead-acid battery for emergency power supply. Must be ordered 2 batteries (system voltage 24 V). Dimensions max. (W x H x D) 153 x 100 x 102 mm FA2005-A1 Battery (12 V, 17 Ah, VDS) Part no. A5Q Features Rechargeable sealed lead-acid battery for emergency power supply. Must be ordered 2 batteries (system voltage 24 V). Dimensions Max. (W x H x D) 183 x 170 x 80 mm FA2006-A1 Battery (12 V, 26 Ah, VDS) Part no. A5Q Features Rechargeable sealed lead-acid battery for emergency power supply. Must be ordered 2 batteries (system voltage 24 V). Dimensions Max. (W x H x D) 177 x 127 x 168 mm 41

42 Batteries FA2007-A1 Battery (12 V, 45 Ah, VDS) Part no. A5Q Features Rechargeable sealed lead-acid battery for emergency power supply. Must be ordered 2 batteries (system voltage 24 V). Dimensions Max. (W x H x D) 200 x 176 x 170 mm FA2008-A1 Battery (12 V, 65 Ah, VDS) Part no. A5Q Features Rechargeable sealed lead-acid battery for emergency power supply. Must be ordered 2 batteries (system voltage 24 V). Dimensions Max. (W x H x D) 355 x 185 x 170 mm FA2009-A1 Battery (12 V, 100 Ah, VDS) Part no. A5Q Features Rechargeable sealed lead-acid battery for emergency power supply. Must be ordered 2 batteries (system voltage 24 V). Dimensions max. (W x H x D) 333 x 224 x 175 mm 42

43 5 Spare parts Spare parts 5.1 Cover caps FHA2011-A2 Cover cap (Sinteso) Part no. A5Q Cover with Sinteso label. As spare part only. 5.2 Printer rolls and typewriter ribbon Thermo printer rolls for Custom Plus-S-0004 Part no. A5Q Replacement printer rolls (10 rolls) for event printer FTO2001-A1. Typewriter ribbon Part no. A5Q Genuine Fujitsu CA02374-C104 black fabric impact printer ribbon designed for the Fujitsu DL3750+ matrix printer. Use as spare part. Color black 43

44 Spare parts 5.3 Power supply SV 24V-150W Power supply Part no. V24230-Z6-A5 Power supply (150 W) without accessories. As spare part only. The power supply V24230-Z6-A5 cannot be used in cascading with previous versions V24230-Z6-A3 or V24230-Z5-A4. 44

45 6 Repair parts Repair parts 6.1 Operating units FCM2001-A2 Operating unit Part no. A5Q R Complete operating unit (support base, keypad, PMI main board, CPU module) without accessories. As repair part only. FCM2002-A2 Operating unit (+LED ind.) Part no. A5Q R Complete operating unit (support base, keypad, PMI main board, CPU module) without accessories. As repair part only. 6.2 Operating add-ons FCM2005-A2 Operating add-on Part no. A5Q R Operating add-on (complete base) without accessories. As repair part only. 45

46 Repair parts 6.3 Periphery boards FCI2002-A1 Periphery board (2-loop) Part no. A5Q R Periphery board (2-loop) without accessories. As repair part only. FCI2004-A1 Periphery board (4-loop) Part no. A5Q R Periphery board (4-loop) without accessories. As repair part only. 6.4 Fire terminal board FTI2001-A1 Fire terminal board Part no. A5Q R Fire terminal board without accessories. As repair part only. 46

47 6.5 Fire brigade periphery module Repair parts FCI2001-D1 Fire brigade periphery module Part no. A5Q R Fire brigade periphery module without accessories. As repair part only. 6.6 Network module (SAFEDLINK) FN2001-A1 Network module (SAFEDLINK) Part no. A5Q R Network module (SAFEDLINK) without accessories. As repair part only. 6.7 Power supply FP2001-A1 Power supply (70 W) Part no. A5Q R Power supply (70 W) without accessories. As repair part only. SV 24V-150W Power supply Part no. V24230-R6-A4 Power supply (150 W) without accessories. Repair part for SV 24V-150W power supply V24230-Z6-A3 / V24230-Z6-A4 The power supply V24230-R6-A4 cannot be used in cascading configuration with SV24-150W power supply V24230-Z6-A5. 47

48 Repair parts 6.8 Floor repeater terminal and floor repeater display FT2010-A1 Floor repeater terminal Part no. A5Q R Front part of the floor repeater terminal (cover cap, stick-on labels, keypad) without accessories. As repair part only. FT2011-A1 Floor repeater display Part no. A5Q R Front part of the floor repeater display (cover cap, stick-on label, keypad) without accessories. As repair part only. 48

FC2020 Fire control panel

FC2020 Fire control panel FC2020 Fire control panel Series FS20 (MP4.0) Sinteso Compact, prefabricated, microprocessor-controlled fire control panel for the connection of up to 252 addresses Fire control panel can be used as stand-alone

More information

FC723 Fire control panel

FC723 Fire control panel FC723 Fire control panel FS720 series (IP5) Cerberus PRO Modular, prefabricated, microprocessor-controlled fire control panel with integrated user-friendly operating unit for up to max. 756 addresses Processes

More information

FC724 Fire control panel

FC724 Fire control panel FC724 Fire control panel Series FS720 (IP5) Cerberus PRO Compact, prefabricated microprocessor-controlled fire control panel for the connection of up to 504 addresses Fire control panel can be used as

More information

FC724 Fire control panel

FC724 Fire control panel FC724 Fire control panel Series FS720 (IP4) Cerberus PRO Compact, prefabricated microprocessor-controlled fire control panel for the connection of up to 504 addresses Fire control panel can be used as

More information

FC722 Fire control panel

FC722 Fire control panel FC722 Fire control panel Series FS720 (IP4) Cerberus PRO Compact, prefabricated microprocessor-controlled fire control panel for the connection of up to 252 addresses Fire control panel can be used as

More information

FC722 Fire control panel

FC722 Fire control panel FC722 Fire control panel Series FS720 (MPXS) Cerberus PRO Compact, prefabricated microprocessor-controlled fire control panel for the connection of up to 252 addresses Fire control panel can be used as

More information

Fire control panel for modernization

Fire control panel for modernization Sinteso Fire control panel for modernization FC2030 Modular, pre-assembled fire control panel with integrated, user-friendly operating unit for gradual migration to Sinteso. Fire control panel for a maximum

More information

FC2040. Fire control panel. Sinteso. FS20 series, MP6

FC2040. Fire control panel. Sinteso. FS20 series, MP6 FC2040 Sinteso Fire control panel FS20 series, MP6 Compact, pre-assembled, microprocessor-controlled fire control panel with integrated operating unit for up to 504 addresses Fire control panel can be

More information

Fire control panels FC726 FC726-XA

Fire control panels FC726 FC726-XA Fire control panels FC726 FC726-XA Modular, pre-confectioned, microprocessor-controlled fire control panel for up to max. 1512 device addresses Integrated, user-friendly operating unit Detection and automatic

More information

Sinteso TM product catalog.

Sinteso TM product catalog. Sinteso product catalog Sinteso TM product catalog. Fire protection products and accessories. Siemens Switzerland Ltd Building Technologies Group International Headquarters Gubelstrasse 22 CH-6301 Zug

More information

Fire control panels FC360

Fire control panels FC360 Cerberus TM FIT Fire control panels FC360 FC361-ZZ, FC361-ZA, FC361-YZ, FC361-YA Fire control panels (1-loop) for addressable peripheral devices with integrated operating unit One loop with 126 addresses

More information

FT2080 Fire terminal (Touch) Mounting Installation

FT2080 Fire terminal (Touch) Mounting Installation FT080 Fire terminal (Touch) Mounting Installation 0-09-0 Control Products and Systems Legal notice Legal notice Technical specifications and availability subject to change without notice. Siemens Switzerland

More information

FT2080 Fire terminal (Touch) Mounting Installation

FT2080 Fire terminal (Touch) Mounting Installation FT080 Fire terminal (Touch) Mounting Installation 06-0-08 Control Products and Systems Legal notice Legal notice Technical specifications and availability subject to change without notice. Transmittal,

More information

FC330A-ECO Auto-addressing analogue 1-Loop fire detection panel

FC330A-ECO Auto-addressing analogue 1-Loop fire detection panel FC330A-ECO Auto-addressing analogue 1-Loop fire detection panel Synova TM Commissioning in no time thanks to automatic address allocation Auto-addressing makes setting dip switches unnecessary Automatic

More information

FDCIO223 (ES 45) Transponder

FDCIO223 (ES 45) Transponder FDCIO223 (ES 45) Transponder Addressed (FDnet/C-NET) Sinteso Cerberus PRO 2 monitored inputs/outputs, which can optionally be used as a detector line (collective Siemens/Cerberus, Synova 600, or collective

More information

Synova TM product catalog.

Synova TM product catalog. Synova product catalog Synova TM product catalog. Fire protection products and accessories. Siemens Switzerland Ltd Building Technologies Group International Headquarters Gubelstrasse 22 CH-6301 Zug Tel

More information

FDCL221-M Multi line separator module

FDCL221-M Multi line separator module FDCL221-M Multi line separator module addressable (FDnet/C-NET) Sinteso TM Cerberus PRO Automatic module with several line separators Creation of T taps (stub lines) in the FDnet/C-NET Operation of the

More information

Input module, input/output module

Input module, input/output module Sinteso / Cerberus PRO Input module, input/output module FDCI221, FDCIO221 Input module and input/output module for the automatically addressed detector line Input module FDCI221: Monitorable contact input

More information

Multi line separator module

Multi line separator module Sinteso Cerberus PRO Multi line separator module FDCL221-M Multi line separator module, addressed (FDnet/C-NET) Automatic module with several separate line separators Formation of stub lines (T-branches)

More information

Input module, input/output modules

Input module, input/output modules Sinteso / Cerberus PRO Input module, input/output modules FDCI222, FDCIO222, FDCIO224 Input module and input/output modules for the automatically addressed detector line Input module FDCI222: Four monitored

More information

FP120-Z1 Power supply kit A (70 W) Technical Manual

FP120-Z1 Power supply kit A (70 W) Technical Manual FP120-Z1 Power supply kit A (70 W) Technical Manual 2015-07-08 Control Products and Systems Legal notice Legal notice Technical specifications and availability subject to change without notice. Transmittal,

More information

FC330A-ECO1 Auto-addressing analogue 1-Loop fire detection panel

FC330A-ECO1 Auto-addressing analogue 1-Loop fire detection panel FC330A-ECO1 Auto-addressing analogue 1-Loop fire detection panel Synova Commissioning in no time thanks to automatic address allocation Auto-addressing makes setting dip switches, punch cards, etc. unnecessary

More information

DC1192 Input /Output module

DC1192 Input /Output module DC1192 Input /Output module Interactive, AnalogPLUS/SynoLOOP, collective/synoline600 AlgoRex Synova In-/output module suitable for collective fire detection system as detection line coupler interactive

More information

FS720 Fire detection system Planning

FS720 Fire detection system Planning FS720 Fire detection system Planning IP6 2015-12-15 Control Products and Systems Legal notice Legal notice Technical specifications and availability subject to change without notice. Transmittal, reproduction,

More information

Output module (230 V)

Output module (230 V) Cerberus FIT Output module (30 V) FCA109-Z1 Output module for use in monitored output lines Output with potential-free relay contacts for controlling fire ventilators, air conditioning systems, elevators,

More information

FC700A Fire detection control unit

FC700A Fire detection control unit FC700A Fire detection control unit Synova 4-16 Loop analogue addressable control panel 128 devices per loop (SynoLOOP) and up to 1000 devices per panel Up to 24 collective lines for Synova TM 600 serie

More information

DC1154 / DC1154-AA / DC1156-AA / DC1157-AA Input / Output modules

DC1154 / DC1154-AA / DC1156-AA / DC1157-AA Input / Output modules DC1154 / DC1154-AA / DC1156-AA / DC1157-AA Input / Output modules Interactive AlgoRex DC1150 Series Thanks to its robust construction, the line modules can be used in both dry and dusty / wet areas Housing

More information

FDS229-R / FDS229-A Alarm sounder with supplementary optical indication

FDS229-R / FDS229-A Alarm sounder with supplementary optical indication FDS229-R / FDS229-A Alarm sounder with supplementary optical indication For the automatic addressable detector bus C-NET and FDnet Cerberus PRO Sinteso Alarm sounder with 11 tonalities selectable, 2 activation

More information

Mimic display driver, LED ribbon cable

Mimic display driver, LED ribbon cable Sinteso / Cerberus PRO Mimic display driver, LED ribbon cable FT2001-A1, F50F410 FDnet/C-NET mimic display driver and LED ribbon cable for the fire detection systems Sinteso FS20 and Cerberus PRO FS720.

More information

Fire safety products and accessories siemens.com/cerberus

Fire safety products and accessories siemens.com/cerberus Cerberus PRO product catalog Fire safety products and accessories siemens.com/cerberus Does anyone know a clever fire safety system starting with a C? Cerberus PRO enjoy protecting! The new generation

More information

FC121-ZA / FC122-ZA / FC123-ZA / FC124-ZA

FC121-ZA / FC122-ZA / FC123-ZA / FC124-ZA Fire Control Panel FC121-ZA / FC122-ZA / FC123-ZA / FC124-ZA Technical Manual 2014-05-28 Control Products and Systems Legal notice Technical specifications and availability subject to change without notice.

More information

Fire control panel detect 3004 plus and accessories

Fire control panel detect 3004 plus and accessories Fire control panel detect 3004 and accessories The modular fire alarm panel detect 3004 is the basic version of a broad product portfolio of the system detect 3000. Up to 20 fire control panels can be

More information

FDOOT241-9, FDOOT241-A, FDO241, FDT241

FDOOT241-9, FDOOT241-A, FDO241, FDT241 Sinteso S-LINE FDOOT241-9, FDOOT241-A, FDO241, FDT241 Automatic fire detectors For the automatically addressed detector bus FDnet The ideal fire detector for every application Line separators for uninterrupted

More information

XC10 Extinguishing control panels

XC10 Extinguishing control panels XC10 Extinguishing control panels Market package 2.1 Advanced control panels for detection and alarming as well as for the activation of the extinguishing process Microprocessor-controlled fire detection

More information

FDCL221-Ex Line adapter (Ex)

FDCL221-Ex Line adapter (Ex) FDCL221-Ex Line adapter (Ex) Addressed (FDnet-Ex/C-NET-Ex) For operating FDnet-Ex/C-NET-Ex peripheral devices in potentially explosive areas Sinteso Cerberus PRO Electrical isolation of Ex and non-ex lines

More information

Manual call points. Sinteso / Cerberus PRO FDM225, FDM226

Manual call points. Sinteso / Cerberus PRO FDM225, FDM226 Sinteso / Cerberus PRO Manual call points FDM225, FDM226 Manual call points with direct activation for the FDnet/C-NET automatic addressable detector bus Manual call points for addressed Sinteso FS20 and

More information

ASA linear smoke detector

ASA linear smoke detector Sinteso / Cerberus PRO ASA linear smoke detector FDL241-9 Linear smoke detector, used addressed or collectively, ASAtechnology TM Reliable smoke detection in large spaces (indoor application) Detection

More information

OOH740, OOHC740. Cerberus PRO. Automatic fire detectors

OOH740, OOHC740. Cerberus PRO. Automatic fire detectors Cerberus PRO OOH740, OOHC740 Automatic fire detectors ASAtechnology For the automatically addressable detector bus C-NET collective / conventional (OOH740 only) Signal processing with ASAtechnology Event-controlled

More information

FDCW241 Radio gateway Mounting

FDCW241 Radio gateway Mounting FDCW241 Radio gateway Mounting 2017-01-05 Control Products and Systems Legal notice Legal notice Technical specifications and availability subject to change without notice. Transmittal, reproduction, dissemination

More information

FDCL221 Line separator

FDCL221 Line separator FDCL221 Line separator Technical manual Fire Safety & Security Products Technical specifications and availability subject to change without notice. 2004-2009 Copyright Siemens, Inc. We reserve all rights

More information

DBS721, DBS729 Sounder interbase, Sounder beacon interbase

DBS721, DBS729 Sounder interbase, Sounder beacon interbase DBS721, DBS729 Sounder interbase, Sounder beacon interbase For the automatic addressable detector bus C-NET Cerberus PRO Sounder interbase DBS721 and sounder beacon interbase DBS729 11 selectable tones,

More information

FDOOT241-A3, FDOOT241-A4, FDOOT241-A5, FDOOT241-A9, FDOOT241-8

FDOOT241-A3, FDOOT241-A4, FDOOT241-A5, FDOOT241-A9, FDOOT241-8 Sinteso S-LINE FDOOT241-A3, FDOOT241-A4, FDOOT241-A5, FDOOT241-A9, FDOOT241-8 Multisensor fire detectors Multi-sensor fire detector for gradual modernization with ASAtechnology For the modernization of

More information

Interbases. Sinteso FDSB221, FDSB228, FDSB229

Interbases. Sinteso FDSB221, FDSB228, FDSB229 Sinteso Interbases FDSB221, FDSB228, FDSB229 Sounder interbase, sounder beacon interbase, sounder interbase with supplementary optical indication for the automatically addressable detector bus FDnet Addressed

More information

FDOOT221, FDO221, FDT221

FDOOT221, FDO221, FDT221 Sinteso C-LINE FDOOT221, FDO221, FDT221 Automatic fire detectors For the automatically addressed detector bus FDnet The ideal fire detector for every application Signal processing with detection algorithms

More information

Desigo TM Fire Safety System A comprehensive fire-protection system

Desigo TM Fire Safety System A comprehensive fire-protection system s Desigo TM Fire Safety System A comprehensive fire-protection system Standard 50-point, 252-point and 504-point-capacity systems Remote viewing for the 252- point and 504-point systems One (1) or (2)

More information

OOH740, OOHC740 Automatic fire detectors

OOH740, OOHC740 Automatic fire detectors OOH740, OOHC740 Automatic fire detectors ASAtechnology TM For the automatic addressable detector bus C-NET Collective / Conventional (OOH740 only) Cerberus PRO Signal processing with ASAtechnology TM Event-controlled

More information

ARCHITECT AND ENGINEER SPECIFICATIONS

ARCHITECT AND ENGINEER SPECIFICATIONS s Desigo Fire Safety System A comprehensive fire-protection system Standard 50-point, 252-point and 504-point-capacity systems Remote viewing for the 252- point and 504-point systems One (1) or (2) two-heightunit

More information

DC1136, DC1131-AA, DC1134-AA, DC1136-AA Input / Output modules

DC1136, DC1131-AA, DC1134-AA, DC1136-AA Input / Output modules DC1136, DC1131-AA, DC1134-AA, DC1136-AA Input / Output modules AnalogPLUS AlgoRex DC1130 Series Thanks to its robust construction, the input/output modules can be used in both dry and dusty / wet areas

More information

Manual call point. Sinteso Cerberus PRO FDM223H, FDM224H. 'Heavy Duty' manual call point addressed (FDnet/C-NET)

Manual call point. Sinteso Cerberus PRO FDM223H, FDM224H. 'Heavy Duty' manual call point addressed (FDnet/C-NET) Sinteso Cerberus PRO Manual call point FDM223H, FDM224H 'Heavy Duty' manual call point addressed (FDnet/C-NET) Manual call points for addressed Sinteso FS20 and Cerberus PRO FS720 fire detection systems

More information

Siemens aspirating smoke detector (ASD) for the addressed FDnet/C-NET detector line or for standalone operation

Siemens aspirating smoke detector (ASD) for the addressed FDnet/C-NET detector line or for standalone operation Sinteso Cerberus PRO FDA241, FDA221 ASD Aspirating smoke detector Siemens aspirating smoke detector (ASD) for the addressed FDnet/C-NET detector line or for standalone operation Patented technology Early

More information

Desigo TM Fire Safety System A comprehensive fire-protection system

Desigo TM Fire Safety System A comprehensive fire-protection system s Desigo TM Fire Safety System A comprehensive fire-protection system Standard 252-point and 504-point capacity systems Remote viewing for the 252- point and 504-point systems One (1) or (2) two-heightunit

More information

13 tones to choose from, 2 programmable alarm levels Adjustable sound levels up to 93 dba

13 tones to choose from, 2 programmable alarm levels Adjustable sound levels up to 93 dba Cerberus PRO Cerberus FIT Interbases DBS721, DBS728, DBS729 Sounder interbase, sounder beacon interbase, sounder interbase with supplementary optical indication for the automatically addressable detector

More information

OH720, OP720, HI720, HI722

OH720, OP720, HI720, HI722 Cerberus PRO OH720, OP720, HI720, HI722 Automatic fire detectors For the automatically addressable detector bus C-NET The ideal fire detector for every application Signal processing with detection algorithms

More information

Fire Detection Systems Product Catalogue (Version )

Fire Detection Systems Product Catalogue (Version ) Fire Detection Systems Product Catalogue (Version 2015-01) Version 2015-01 Product Catalogue Fire Detection Systems This product catalogue is intended for sales purposes only. For planning, installation,

More information

FDCI221, FDCIO221 Input module, input/output module Technical Manual

FDCI221, FDCIO221 Input module, input/output module Technical Manual FDCI221, FDCIO221 Input module, input/output module Technical Manual 2012-09-30 Control Products and Systems Legal notice Legal notice Technical specifications and availability subject to change without

More information

Call stations and extensions

Call stations and extensions Novigo Call stations and extensions PT2001-A1, PT2002-A1, PT2008-A1, PT2009-A1, PTO2001-A1, PTO2002-A1, PTO2003-A1, PTO2004-A1, PTO2005-A1, PTO2006-A1, PTO2008-A1 EN 54-16-certified alarm and business

More information

On the job around the clock 24/7: Fire detection systems

On the job around the clock 24/7: Fire detection systems On the job around the clock 24/7: Fire detection systems Version 02.2010 Version: 02.2010 Product catalogue Fire detection systems This product catalogue is intended for sales purposes only. For planning,

More information

DM1153H-Ex / DM1154H-Ex Manual call point 'Heavy Duty'-Ex

DM1153H-Ex / DM1154H-Ex Manual call point 'Heavy Duty'-Ex DM1153H-Ex / DM1154H-Ex Manual call point 'Heavy Duty'-Ex Interactive, for explosion-hazard area of zones 1 and 2 AlgoRex Manual call point to the interactive fire detection system with microprocessor,

More information

FDBZ290 Air sampling smoke detection kit

FDBZ290 Air sampling smoke detection kit FDBZ290 Air sampling smoke detection kit Sinteso Cerberus PRO Reliable monitoring for smoke of supply air, exhaust air and recirculation ducts of air conditioning and ventilation systems Suitable for air

More information

Cerberus TM PRO Fire Safety System A comprehensive fire-protection system

Cerberus TM PRO Fire Safety System A comprehensive fire-protection system s Data Sheet Fire Safety & Security Products Cerberus TM PRO Fire Safety System A comprehensive fire-protection system Standard 50-point, 252-point and 504-point-capacity systems Remote viewing for the

More information

FDBZ290 Air sampling smoke detection kit

FDBZ290 Air sampling smoke detection kit FDBZ290 Air sampling smoke detection kit Sinteso Cerberus PRO Reliable monitoring for smoke of supply air, exhaust air and recirculation ducts of air conditioning and ventilation systems Suitable for air

More information

DB110xA, DB1131A, SO620A, DB1151A Detector bases and accessories

DB110xA, DB1131A, SO620A, DB1151A Detector bases and accessories DB110xA, DB1131A, SO620A, DB1151A Detector bases and accessories interactive, AnalogPLUS/SynoLOOP, collective/synoline600 AlgoRex Synova TM Base made of impact and scratch-proof plastic Screw less terminals

More information

FDF Sinteso Cerberus PRO Cerberus FIT. Flame detector. Flame detector addressed or collective, ASAtechnology TM

FDF Sinteso Cerberus PRO Cerberus FIT. Flame detector. Flame detector addressed or collective, ASAtechnology TM Sinteso Cerberus PRO Cerberus FIT FDF241-9 Flame detector Flame detector addressed or collective, ASAtechnology TM Reliable detection using three infrared sensors and ASAtechnology (indoor and outdoor

More information

FS720 Fire detection system (marine) Technical Manual

FS720 Fire detection system (marine) Technical Manual FS720 Fire detection system (marine) Technical Manual 2016-05-10 Control Products and Systems Legal notice Legal notice Technical specifications and availability subject to change without notice. Transmittal,

More information

FC721 Fire control panel Technical Manual

FC721 Fire control panel Technical Manual FC721 Fire control panel Technical Manual IP6 2015-12-15 Control Products and Systems Legal notice Legal notice Technical specifications and availability subject to change without notice. Transmittal,

More information

FDOOT241-A9-Ex Multisensor fire detector

FDOOT241-A9-Ex Multisensor fire detector FDOOT241-A9-Ex Multisensor fire detector ASAtechnology TM For potentially explosive areas Sinteso Collective Signal processing with ASAtechnology Multiple protocol detector (collective/fdnet-ex) Event-controlled

More information

OOH740-A9-Ex Multi-sensor fire detector

OOH740-A9-Ex Multi-sensor fire detector OOH740-A9-Ex Multi-sensor fire detector ASAtechnology TM For potentially explosive areas Cerberus PRO Collective Signal processing with ASAtechnology Multiple protocol detector (collective/c-net-ex) Event-controlled

More information

DM1131 / DM1133 / DM1134 Manual call points

DM1131 / DM1133 / DM1134 Manual call points DM1131 / DM1133 / DM1134 Manual call points AnalogPLUS/SynoLOOP AlgoRex Synova Manual call points to the fire detection system AnalogPLUS/SynoLOOP Manual call point DM1131 with direct operation Manual

More information

OOH740-A9-Ex Multisensor fire detector

OOH740-A9-Ex Multisensor fire detector OOH740-A9-Ex Multisensor fire detector ASAtechnology TM For potentially explosive areas Cerberus PRO Collective Signal processing with ASAtechnology Multiple protocol detector (collective/c-net-ex) Event-controlled

More information

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL PRODUCT Specification FEATURES Designed To Meet The Requirements Of EN54 Expandable From 1 To 5 Loops As Standard A Variety Of Networking Options

More information

Cerberus FIT conventional system

Cerberus FIT conventional system Cerberus FIT conventional system Combining intelligent signal processing and easy installation for reliable fire detection and alarming www.siemens.com/cerberus-fit Reliable, intelligent and cost-efficient

More information

Building Technologies SIGMASYS M Multifunctional danger alarm control and indicating panel

Building Technologies SIGMASYS M Multifunctional danger alarm control and indicating panel R33/422 Building Technologies SIGMASYS M Multifunctional danger alarm control and indicating panel SIGMASYS M multifunctional danger alarm control and indicating panel Application Description Features

More information

FDM273 Radio manual call point Mounting

FDM273 Radio manual call point Mounting FDM273 Radio manual call point Mounting 2016-11-28 Control Products and Systems Legal notice Legal notice Technical specifications and availability subject to change without notice. Transmittal, reproduction,

More information

Cerberus PRO A comprehensive fire-protection system

Cerberus PRO A comprehensive fire-protection system Cerberus PRO A comprehensive fire-protection system Cerberus TM ARCHITECT AND ENGINEER SPECIFICATIONS Standard 252-point and 504-point fire systems Remote viewing for the 252- point and 504-point systems

More information

The EN54 Part 2 & 4 Fire System

The EN54 Part 2 & 4 Fire System Scope of work: To design, supply, install and commission an Analogue Addressable Fire Alarm Control System in accordance with the details specified herein and in accordance with supplied drawings The EN54

More information

DF1101-Ex Infrared flame detector

DF1101-Ex Infrared flame detector DF1101-Ex Infrared flame detector Collective/SynoLINE 600 for explosion-hazard areas of zones 1 and 2 AlgoRex Synova Sinteso Cerberus PRO For inside and outside applications Triple-sensor evaluation Detection

More information

FT2011 Floor repeater display Operation Manual

FT2011 Floor repeater display Operation Manual FT2011 Floor repeater display Operation Manual MP6 2015-12-15 Control Products and Systems Legal notice Legal notice Technical specifications and availability subject to change without notice. Transmittal,

More information

Discovery 4 Loop Analogue Addressable Control Panel (NVI & NVA series Protocols)

Discovery 4 Loop Analogue Addressable Control Panel (NVI & NVA series Protocols) Nitin Ventures FZE. (A Division of Nitin Fire Protection Industries Ltd.) BETTER TO BE SAFE Discovery Analogue Addressable Fire Alarm Panels Discovery 4 Loop Analogue Addressable Control Panel (NVI & NVA

More information

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices. FireCell Radio Hub Fully addressable Wireless activation Third party approved (EN54) 2-way radio communication Loop powered Diagnostics port Range in excess of 150 metres Overview The model FCX-500-001

More information

561-MB256 plus. Intruder alarm control panel. Performance features

561-MB256 plus. Intruder alarm control panel. Performance features 561-MB256 plus Intruder alarm control panel The intruder alarm control panel 561-MB256 plus is designed for use in private and commercial zones and is highly suitable for setting up medium to large-sized

More information

2015 NEW. Cerberus ECO. enjoy protecting. Product Brouchure. siemens.com/buildingtechnologies

2015 NEW.  Cerberus ECO. enjoy protecting. Product Brouchure. siemens.com/buildingtechnologies 2015 NEW www.siemens.com/buildingtechnologies Cerberus ECO enjoy protecting Product Brouchure siemens.com/buildingtechnologies Cerberus ECO enjoy protecting Lives and businesses deserve reliable protection

More information

DOW1171 / DCW1151 Radio fire detection system

DOW1171 / DCW1151 Radio fire detection system DOW1171 / DCW1151 Radio fire detection system Interactive AlgoRex Complete integration in the interactive fire detection system CS1140 Simultaneous operation of wired and wireless fire detectors New possibilities

More information

ZXSe Range. Fire Safety. Analogue addressable fire alarm control panel KEY FEATURES. Panel Features

ZXSe Range. Fire Safety. Analogue addressable fire alarm control panel KEY FEATURES. Panel Features Fire Safety ZXSe Range Analogue addressable fire alarm control panel The ZXSe range of analogue addressable fire alarm control panels have been designed and constructed around proven and reliable microprocessor

More information

FT2010 Floor repeater terminal Operation Manual

FT2010 Floor repeater terminal Operation Manual FT2010 Floor repeater terminal Operation Manual MP5 / IP5 2013-11-14 Control Products and Systems Legal notice Legal notice Technical specifications and availability subject to change without notice. 2013

More information

DM1101 / DM1103 / DM1104 DM1103-L / DM1103-S Manual call points Manual release button and emergency stop button

DM1101 / DM1103 / DM1104 DM1103-L / DM1103-S Manual call points Manual release button and emergency stop button DM1101 / DM1103 / DM1104 DM1103-L / DM1103-S Manual call points Manual release button and emergency stop button collective/synoline600 AlgoRex Synova Manual call point to all fire detection system control

More information

FDCW221 / DOW1171 / SMF121 SMF6120 (repair/replacement) Radio fire detection system

FDCW221 / DOW1171 / SMF121 SMF6120 (repair/replacement) Radio fire detection system FDCW221 / DOW1171 / SMF121 SMF6120 (repair/replacement) Radio fire detection system Addressed (FDnet) Sinteso Full integration into FS20, SIGMASYS, and AlgoRex fire detection systems Simultaneous operation

More information

FDBZ290 Air sampling smoke detection kit Technical Manual

FDBZ290 Air sampling smoke detection kit Technical Manual FDBZ290 Air sampling smoke detection kit Technical Manual 2015-12-17 Control Products and Systems Legal notice Legal notice Technical specifications and availability subject to change without notice. Transmittal,

More information

Desigo Fire Safety Marine Fire and Detection Equipment Models FH-2071-UM, BP-62 and USCG-HPLATE

Desigo Fire Safety Marine Fire and Detection Equipment Models FH-2071-UM, BP-62 and USCG-HPLATE s Desigo Fire Safety Marine Fire and Detection Equipment s FH-2071-UM, BP-62 and USCG-HPLATE ARCHITECT AND ENGINEER SPECIFICATIONS Marine equipment is used with Desigo 252-point and 504-point addressable

More information

FDA241, FDA221 Aspirating Smoke Detector Technical Manual

FDA241, FDA221 Aspirating Smoke Detector Technical Manual FDA241, FDA221 Aspirating Smoke Detector Technical Manual 2015-09-29 Control Products and Systems Legal notice Legal notice Technical specifications and availability subject to change without notice. Siemens

More information

Building Technologies. FDUL221 en Line tester operating instructions for electricians

Building Technologies. FDUL221 en Line tester operating instructions for electricians FDUL221 en Line tester operating instructions for electricians 1. Intended use The FDUL221 line tester is used to diagnose an addressed detector line in FDnet/C-NET. During diagnosis, the detector line

More information

FDA241, FDA221 Siemens ASD

FDA241, FDA221 Siemens ASD FDA241, FDA221 Siemens ASD Patented Technology Sinteso TM Cerberus PRO Compatible with the Siemens FDnet/C-NET loops (requires FDCC221S option) Advanced dual Wavelength optical detection (Blue & Infra-red)

More information

MK8000 OPC Server Interface Specification for CS1115 Building Technologies

MK8000 OPC Server Interface Specification for CS1115 Building Technologies MK8000 OPC Server Interface Specification for CS1115 Data and design subject to change without notice. / Supply subject to availability. Copyright by Siemens Switzerland Ltd We reserve all rights in this

More information

DF1151-Ex Infrared flame detector

DF1151-Ex Infrared flame detector DF1151-Ex Infrared flame detector Interactive, for explosion-hazard areas of zones 1 and 2 AlgoRex For inside and outside applications Triple-sensor evaluation Detection in various wavelengths Microprocessor-controlled

More information

Inside a typical. Intelligent Voice Communication System. Mounting Diagram. 2 Cerberus PRO. 252 / 504-point Cerberus PRO fire / voice system

Inside a typical. Intelligent Voice Communication System. Mounting Diagram. 2 Cerberus PRO. 252 / 504-point Cerberus PRO fire / voice system Data Sheet Cerberus PRO Intelligent Voice Communication Advanced fire-protection system with integrated voice evacuation ARCHITECT AND ENGINEER SPECIFICATIONS Powerful, intelligent and user-friendly fire

More information

Modular Fire Panel 5000 Series Just as flexible as your plans

Modular Fire Panel 5000 Series Just as flexible as your plans Modular Fire Panel 5000 Series Just as flexible as your plans 2 One modular system does it all Unbeatable flexibility With the Modular Fire Panel 5000 Series, Bosch is again redefining the market: With

More information

FDCIO223 Input / output module (transponder)

FDCIO223 Input / output module (transponder) FDCIO223 Input / output module (transponder) Technical manual Valid for product version ES 45 Fire Safety Technical specifications and availability subject to change without notice. Siemens Switzerland

More information

Not to be distributed outside of FM Approvals and its affiliates except by Customer APPROVAL REPORT. BU-110 and BV-110 Loop Based Displays

Not to be distributed outside of FM Approvals and its affiliates except by Customer APPROVAL REPORT. BU-110 and BV-110 Loop Based Displays Not to be distributed outside of FM Approvals and its affiliates except by Customer APPROVAL REPORT Project No: 0003053331 Supplements Project No.: 3034449 Class: 3010 Product Name: BU-110 and BV-110 Loop

More information

System 800 Addressable Fire Detection & Alarm System

System 800 Addressable Fire Detection & Alarm System SECTION 5: page 1 Section 5: System 800 Addressable Fire Detection & Alarm System SECTION 5: page 3 10 reasons to specify 800 1 Plug and Play A user friendly panel not requiring special software tools

More information

Radio fire detection system

Radio fire detection system OEM Radio fire detection system FDOOT271-O, FDM273-O, FDM275-O Radio fire detection system Multihop mesh technology High transmission reliability thanks to the use of independent communication paths transmission

More information

Engineering Guideline. pac-carriers Type SIEMENS ET-200M Fail-safe signal modules

Engineering Guideline. pac-carriers Type SIEMENS ET-200M Fail-safe signal modules Engineering Guideline pac-carriers Type 9195 SIEMENS ET-200M Fail-safe signal modules pac-carrier Type 9195 2 Engineering Guideline/SIEMENS 19.05.2015 pac-carrier Type 9195 Integration of conventional

More information