1 UDC NATIONAL STANDARD OF THE PEOPLE s REPUBLIC OF CHINA 中华人民共和国国家标准 p GH Specification for Design of Combustible Gas and Toxic Gas Detection and Alarm for Petrochemical Industry 石油化工可燃气体和有毒气体检测报警设计规范 GB/T How to BUY & immediately GET a full-copy of this standard? Search --> Add to Cart --> Checkout (3-steps); 3. No action is required - Full-copy of this standard will be automatically & immediately delivered to your address in 0~60 minutes. 4. Support: Sales@ChineseStandard.net. Wayne, Sales manager Issued on: March 19, 2009 Implemented on: October I, 2009.Jointly Issued by Ministry of Housing and Urban-Rural Construction of the People s Republic of China General Administration of Quality Supervision, lns1 ection and Quarantine of the People s Republic of China
2 Contents General Provisions Terms General Requirements Determination of Detection Points General Rules Process Unit Storage and Transportation Fa 巳 iliti 巳 s Other Combustible Gas or Toxic Gas Diffusion and Accumulation Site Combustible Gas And Toxic Gas Detection Alarm System Technical Performanc 巳 Selection of Detector Selection oflndication Alarm Device Detectors and Indication Apparatus Installation Detector Installation Indication Appara 饥 is and Onsite Alarm Installation Appendix A Properties of General Combustible Gas and Vapor 吃 Appendix B Properties of General Toxic Gas and Vapor Appendix C Technical Performance Table of Detector for General Gasses Explanation of Wording in This Code
3 1 General Provisions This standard is formulated with a view to preventing personal injury, and fire and explosion accidents, and ensuring the safety of petrochemical enterprises This standard is applicable to the combustible gas and toxic gas detection and alarm design of new, expended or rebuilt works for petrochemical enterprises Besides the provisions of this standard, the combustible gas and toxic gas detection and alarm design for petrochemical industry shall meet the requirements of the current related national standards.
4 2 Terms Combustible gas It is referred to Class A combustible gas or the combustible gas generated after Class A and B flammable liquid gasi 马 r ing Toxic gas It is referred to the Gasses which cause acute or chronic health harms on workers by body contact in the employment activities. The scope of toxic gas in this standard is toxic vapour toxic gas listed in acute toxic substances" (Wei Fa Jian Fa [2003] No.142). The general toxic vapours or toxic gases are as: nitrogen dioxide, hydrogen sulfide, benzene, hydrogen cyanide, ammonia, chlorine gas, carbon monoxide, acrylonitrile, vinyl chloride and phosgene Source of release It is referred to the Position or site which releases explosive gas mixture or toxic gas Detector It is referred to the electronic unit which can convert the concentration of combustible gas and toxic gas into electrical signal, and it is composed of sensor and transducer Indication apparatus It is referred to the electronic devices which receive the output signal of detector and send Indication, alarm and control signals Sensible range It is referred to the range of the detected gas that can be detected by detector under the test condition Alarm set value It is referred to the pre-set alarm concentration value of warning device Response time It is referred to the time from detector contacting gas to stably indicating value under test condition. 90% of the time to reach the stable indicated value is adopted as response time; 10% of the time to restore to stable indicated value is adopted as recovery time Vertical height It is referred to the vertical distance from the detection opening of detector to the appointed reference object Lower explosion limit (LEL) It is re 也 rred to the concentration value (V %) of combustible gas at lower explosion limit 2
5 3 General Requirements When possible combustible gas and toxic gas leak is detected in the area for process unit producing or using combustible gas and toxic gas, and for storage and transportation facilities, combustible gas and toxic gas detector shall be arranged according to the following prov1s1ons: 1 Combustible gas or combustible gas with toxic gas is leaked, and the concentration of combustible gas may reach 25% of the lower explosion limit nut the toxic gas cannot reach maximum allowable Concentration. At this time, combustible gas detector shall be equipped; 2 Combustible gas or combustible gas with toxic gas is leaked, and the concentration of combustible gas may reach the lower explosion limit nut the toxic gas cannot reach 25% of maximum allowable Concentration. At this time, toxic gas detector shall be equipped; 3 In the place where combustible gas and toxic gas are stored together, the concentration of combustible gas may reach 25% of lower explosion limit, and the concentration of toxic gas may also reach maximum allowable Concentration. At this point, combustible gas and toxic gas detectors shall be all equipped; 4 When a gas is both combustible gas and toxic gas, only toxic gas detector shall be equipped Two-level alarm shall be adopted for the detection system of combustible gas and toxic gas. When the toxic gas and combustible gas detectors simultaneously alarm in same detection area, the following principles shall be complied with: 1 In same level alarm, toxic gas alarm shall be preferential; 2 Level 2 alarm has priority over level 1 alarm If the process has special requirements, or runs normally, staffs must not ent 巳 r hazardous area, continual detection, Indication and alarm should be taken for the release source of combustible gas and toxic gas, and alarm should be recorded and printed Alarm Signal shall be sent to site warning device and indication apparatus at attended control room or site operation room, and audible and visual alarm shall be available. 3.0.S The arrangement of the site warning devices in equipment zone shall be determined according to the following factors: area of equipment zone, arrangement of equipment and structure, physico-chemical properties of release source and site air flow character. Site warning device may be sounder or alarm lamp Combustible gas detector shall be the products which the measuring instrument production certification, explosion protection performance certification and fire control certification are approved by the institution designated by the country Toxic gas detector specified by the laws of the country shall be the products which the measuring instrument production certification is approved by the institution designated or 4
6 4 Determination of Detection Points 4.1 General Rules The detection points of combustible gas and toxic gas detectors shall be arranged on the positions where gas is easy to accumulate and sampling or detection is convenient, according to the following conditions: gas physicochemical property, characteristic of release source, production yard layout, geographic conditions, environmental climate and operating and patrol examining route Detection points shall be arranged for the following release sources with possible combustible gas or toxic gas leak: 1 Sealing of gas compressor and liquor pump; 2 Liquid and gas sampling ports; 3 Liquor drainage opening or vent; 4 Flange and valving for equipment and pipes. 4.2 Process Unit When release sources are located on the equipment sections of open-air or open-type facility Layout, the distance from detection point and release source shall meet the following requirements: 1 When the detection point is located on windward Side of the all-the-year least frequency wind direction, the distance from combustible gas detection point to release source should not be larger than 1 Sm, and the distance from toxic gas detection point to release source should not be larger than 2 m; 2 When the detection point is located on leeside of the all-the-year least 仕 equency wind direction, the distance from combustible gas detection point to release source should not be larger than Sm, and the distance from toxic gas detection point to release source should not be larger than 2 m; When combustible gas release source is located on semi-open workshop building of closing or imperfect local ventilation, a detector may be ranged per I Sm, and the distance from the detector to any release source within this coverage should not be larger than 7.Sm. The distance from Toxic gas detector to the release source should not be larger than lm When lighter-than-air combustible gas or Toxic gas release source is located on semiopen workshop building of closing or imperfect local ventilation, detector shall be arranged over the release source, beside combustible gas or toxic gas detector shall be arranged on the highest position where gas is easy to accumulate in the workshop building. 6
7 4.3 Storage and Transportation Facilities Detectors shall be arranged in fire dike of the stock tanks for Liquids (like liquefied hydrocarbon, Class A2 and Bl Liquids) that generate combustible g 邸, and th 巳 y shall meet the following requirements: 1 When the detection point is located on windward Side of the all-the-year least frequency wind direction, the distance from combustible gas detection point to release source should not be larger than 15m, and the distance 企 om toxic gas detection point to release source should not be larger than 2m; 2 When the detection point is located on leeside of the all-the-year least frequency wind direction, the distance from combustible gas detection point to release source should not be larger than 5m, and the distance from toxic gas detection point to release source should not be larger than 2m; The arrangement of loading and unloading facilities for liquefied hydrocarbon Class A2 and Bl liquids shall be in accordance with the following requirements: 1 As for railway loading and unloading trestle work with small crane, a detector should be arranged every other berth on the ground, and the horizon distance from the detector to the loader opening shall not be larger than 15m; 2 A detector should be arranged for railway loading and unloading trestle work with large crane; 3 The horizon distance from detector to lorry loader crane on lorry loading depot shall not be larger than 15m. When buffer tank is equipped on lorry loading depot, the arrangement of detector shall meet the requirements of Article The detectors for pump or compressor on loading and unloading facilities shall meet the requirements of Section The arrangement of the detectors for liquefied hydrocarbon tank filling station shall be in accordance with the following requirements: 1 Between sealed or semi-open tanks, the distance from filling tank open to detector should be 5m~ 7.Sm; 2 The storehouse for sealed or semi-open tanks shall meet the requirements of Article 4.2.2; a detector shall be arranged on per l Sm~ 30m along the circle on open tank storehouse. When the total side of the circle is less than l Sm, a detector shall be equipped; 3 The distance from buffer tank drainage outlet or valve box to detector should be 5m~ 7.5m Between sealed or semi-open hydrogen gas tank, detectors shall be arranged on the indoor highest position (over the opening of the tank) where gas is easy to accumulate At discharging quay with potential combustible gas transpiration, a detector shall be arranged within 1 Sm on the horizontal plane of loading arm. 7
8 5 Combustible Gas And Toxic Gas Detection Alarm System 5.1 Technical Performance The output signal of detector should be digital signal, contact signal, milli-ampere signal or Millivolt signal The warning system shall have historical event recording function The technical performance of the system shall meet the requirements of the current national standard Gas Monitors and Alarms for Workplace Atmosphere General Technical Requirements" GB 12358, and Combustible Gas Alarm Control Units" GB 16808; the explosion protection Performance of the system shall meet the requirements of the current national standard Electrical Appara 阳 s Used in Explosive Atmosphere" GB Selection of Detector The selection of combustible gas and toxic gas detector shall be determined according to the technical performance of detector, physicochemical property of detected gas and production environment feature The selection of detector for general gas shall meet the following provisions: 1 Catalytic combustion or infrared gas detector may be adopted for hydrocarbon combustible gas. When air in the usage space contains the media that can poison catalytic combustion detecting element (such as sulphur, Phosphorus, silicon, lead and halogen compound), catalytic combustion detector with toxin Immunity shall be adopted; 2 Infrared gas detector should be adopted at the place of oxygen deficit or higher corros1vity; 3 Catalytic combustion Type, electrochemistry Type, heat conduction Type or semiconductor Type detector may be adopted for detecting hydrogen gas; 4 Heat conduction Type detector should be adopted to detect single-component combustible gas; 5 Chemical type or semiconductor Type detector may be adopted for detecting hydrogen sulfide, chlorine, alkaline air and acrylonitrile gas; 6 Semiconductor Type or photoionization Type detector may be adopted for detecting vinyl chloride gas; 7 Electrochemistry type detector should be adopted for detecting hydrogen cyanide gas; 8 Semiconductor Type or photoionization Type detector may be adopted for detecting benzene gas; 9 Chemical type or in 企 ared gas detector may be adopted for detecting phosgene. 9
Code for Design of Clean Room
Translated English of Chinese Standard: GB50073-2013 www.chinesestandard.net Sales@ChineseStandard.net GB NATIONAL STANDARD OF THE PEOPLE S REPUBLIC OF CHINA UDC P GB 50073-2013 Code for Design of Clean
More informationDetection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Certifications. The Fixed Gas Detection People
Fixed Gas Detector Detection of explosive gases, toxic gases or oxygen Infrared XP version SIL 2 high reliability IP 66 Certifications The Fixed Gas Detection People The OLC/OLCT CT range of fixed ddetectors
More informationOLC(T) 100 FIXED GAS DETECTOR
Fixed Gas Detector OLC(T) FIXED GAS DETECTOR Detection of explosive gases, toxic gases or oxygen Infrared XP version SIL 2 high reliability IP 66 Aluminium or Stainless Steel version CERTIFICATIONS The
More informationProcess Control PIP PCEA001 Fixed Gas Detection Guidelines
November 2015 Process Control PIP PCEA001 PURPOSE AND USE OF PROCESS INDUSTRY PRACTICES In an effort to minimize the cost of process industry facilities, this Practice has been prepared from the technical
More informationDetection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Aluminium or Stainless Steel version
Fixed Gas Detector Detection of explosive gases, toxic gases or oxygen Infrared XP version SIL 2 high reliability IP 66 Aluminium or Stainless Steel version Certifications Pending The Fixed Gas Detection
More information3M Oldham OLCT 100. Description. Fixed Gas Detector
Fixed Gas Detector Description The OLC/OLCT range of fixed detectors has been designed for detection of combustible gases, toxic gases or oxygen. Available in explosion-proof or intrinsically safe versions,
More informationLGCNCOE Study Guide: Fixed Gas Detection
LGCNCOE Study Guide: Fixed Gas Detection References Regulatory International Gas Carrier Code (IGC) regulation 13.6 Gas Carrier Code (GC) regulation 13.6 Existing Gas Carrier Code regulation 13.6 46 CFR
More informationT.ex Single Gas Detector VISA
T.ex Single Gas Detector The T.ex is newest instrument in the Promat portfolio. The instrument is currently available in Oxygen, Hydrogen Sulphide and Carbon Monoxide versions. A Bump Test Station is available
More information3years. Detection of explosive gases, toxic gases and oxygen. Infrared XP IR version. SIL 2 high reliability IP 66.
Fixed Gas Monitoring Solutions Detection of explosive gases, toxic gases and oxygen Infrared XP IR version SIL 2 high reliability IP 66 E n o r t c e l i c 3years W a r r a t n y Certifications: The Fixed
More informationGB Translated English of Chinese Standard: GB NATIONAL STANDARD OF THE
Translated English of Chinese Standard: GB26149-2017 www.chinesestandard.net Sales@ChineseStandard.net GB NATIONAL STANDARD OF THE PEOPLE S REPUBLIC OF CHINA ICS 43.040.10 T 35 GB 26149-2017 Replacing
More informationcompact detector Detection of more than 200 flammable and toxic gases iso 9001:2008
iso 9001:2008 Quality Management Systems Systéme de Qualité www.sgs.com possibility of additional functions detection of critical temperature detection of flooding electrochemical sensor catalytic sensor
More informationQuality. Water. Water Quality. Testing. Testing. Toxic Gas Detection. Toxic Gas. Detection. Air Quality. Monitoring. Monitoring. Monitoring.
Water Quality Labo- Soil/ Soil/ Sedi- Sam- & Air / Dust Toxic gases are present in a wide variety of industrial and civil installations and their detection and monitoring is crucial for the safe working
More informationVASTHI ENGINEERS. Vasthi Multi Gas Monitor/Analyzer. Sheet No. 1 of 4. Vasthi Multi Gas monitor/analyzer with alarm and Graphical Display.
Sheet No. 1 of 4 monitor/analyzer with alarm and Graphical Display. Sheet No. 2 of 4 It specially designed to analyze any gas of your choice, its automatic operation, accurate measurement and crystal clear
More informationOLCT 100 DETECTION DE GAZ FIXE. Certifications. Better detection. Better protection. Detection of Combustible, Toxic or Oxygen gases
DETECTION DE GAZ FIXE OLCT Detection of Combustible, Toxic or Oxygen gases Infrared XP version SIL 2 high reliability IP 66 Aluminium or Stainless Steel version Certifications Better detection. Better
More informationAQ Translated English of Chinese Standard: AQ WORK SAFETY INDUSTRY STANDARD
Translated English of Chinese Standard: AQ4273-2016 www.chinesestandard.net Buy True-PDF Auto-delivery. Sales@ChineseStandard.net WORK SAFETY INDUSTRY STANDARD GB OF THE PEOPLE S REPUBLIC OF CHINA ICS
More information--> Buy True-PDF --> Auto-delivered in 0~10 minutes. QB/T Translated English of Chinese Standard: QB/T
Translated English of Chinese Standard: QB/T4975-2016 www.chinesestandard.net Sales@ChineseStandard.net LIGHT INDUSTRY STANDARD QB OF THE PEOPLE S REPUBLIC OF CHINA ICS 97.030 Classification number: Y61
More informationGas Detection. - Disposable - Serviceable. Single Gas Detectors
Gas Detection Single Gas Detectors Introduction Portable single gas detectors are used for personal protection and have the ability to detect a single gas hazard. Typically they are small, lightweight
More informationDräger Catalytic Ex-Sensors DrägerSensors
Dräger Catalytic Ex-Sensors DrägerSensors High product quality, low operational costs: Thanks to DrägerSensor CatEx PR technology, our sensors are resistant to poisoning and particularly stable over the
More informationProduct Selection Guide Fixed Gas Detection Systems for Personnel & Equipment Safety
Product Selection Guide Fixed Gas Detection Systems for Personnel & Equipment Safety GDS Corp gas monitors, controllers and sensors satisfy today s needs for safety and reliability in critical gas detection
More informationG-TECTA TM. Portable Gas Detection Instruments
G-TECTA TM Portable Gas Detection Instruments 2 Why Linde gas detection? The Linde Group is a global leader in the supply of gases, we provide expertise and product solutions to industry, commerce, science
More informationEAGLE 2. 6 Channel Capacity. Inlet fitting. Loud buzzer (95dB) IrDA communication port Low flow shutoff and alarm Alarm LED s with wide visibility
EAGLE 2 Inlet fitting Loud buzzer (95dB) IrDA communication port Low flow shutoff and alarm Alarm LED s with wide visibility Internal / external hydrophobic filters Self healing polyurethane protective
More informationDräger Catalytic Ex-Sensors DrägerSensors
Dräger Catalytic Ex-Sensors DrägerSensors High product quality, low operational costs: Thanks to DrägerSensor CatEx PR technology, our sensors are resistant to poisoning and particularly stable over the
More informationDräger X-am 7000 Multi-Gas Detection
Dräger X-am 7000 Multi-Gas Detection Dräger X-am 7000 is the solution for the simultaneous and continuous measurement of up to five gases. It is the ideal companion in a variety of applications where the
More informationGB Translated English of Chinese Standard: GB
Translated English of Chinese Standard: GB4706.100-2009 www.chinesestandard.net Sales@ChineseStandard.net GB NATIONAL STANDARD OF THE PEOPLE S REPUBLIC OF CHINA ICS 13.120 Y 69 GB 4706.100-2009 Household
More informationChoosing the best confined space gas detector
AP1003: Choosing the best confined space gas detector The best confined space gas detector doesn t come from any one manufacturer; it s the instrument that best fulfills the requirements for your confined
More informationREMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS
REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS FEATURES Extremely wide range of sensors Easy installation and maintenance Low cost of ownership Replacement of sensors are simple Rugged and reliable
More informationGB/T / IEC 62423:2009
Translated English of Chinese Standard: GB/T22794-2017 www.chinesestandard.net Buy True-PDF Auto-delivery. Sales@ChineseStandard.net GB NATIONAL STANDARD OF THE PEOPLE S REPUBLIC OF CHINA ICS 29.120;29.120.50
More informationKAE Gas Alarm Operation Manual
KAE Gas Alarm Operation Manual Henan Hanwei Electronics Co.,Ltd ISO9001-2008 Precautions: To avoid personal safety injury, Instrument damage and potential dangerous accident; do not use gas detector before
More informationE1000 Portable gas detector
E1000 Portable gas detector Operation manual Ver:HWWM161229CG Read this manual carefully before using the device Table of Contents SAFETY INFORMATION... - 1-1. BRIEF INTRODUCTION... - 3-2. MAIN FUNCTION
More informationAGT 1 Confined Space. Authorised Gas Tester 1. Scienco Limited. Authorised Gas Tester 1 1
Scienco Limited AGT 1 Confined Space Authorised Gas Tester 1 Instructor: Gary Taylor E-Mail: gary@scienco.com Phone: +44 117 971 0001 Office: 10 Chapel Way, Bristol UK BS4 4EU Office Hours: 08:30 to 17:00
More information5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots
5 Operating Modes GX-6000 Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots GX-6000 5 Operating modes Normal Leak Check Inert Bar hole Snap Log Monitor up to
More information5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots
5 Operating Modes GX-6000 Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots CONFINED SPACE ENTRY Monitor LEL, O2, CO, and H2S Internal sample pump Pull samples
More informationESD500. ESD500 Combustible / Toxic Gas Detector
ESD500 ESD500 Combustible / Toxic Gas Detector Combustible and toxic gas leakage inspection instrument in industrial application Ex-proof certificate Exd ⅡC T6 Gb/Ex d ib ⅡC T6 Gb Dust Ex-proof certificate
More informationYY / IEC :2004
Translated English of Chinese Standard: YY0505-2012 www.chinesestandard.net Sales@ChineseStandard.net YY NATIONAL STANDARD OF THE PEOPLE S REPUBLIC OF CHINA ICS 11.140 C 30 YY 0505-2012 / IEC 60601-1-2:2004
More informationOXYGEN. 21% in air. Does not burn - Supports combustion. Increased oxygen will intensify burning
FIRE Rapid self-sustaining oxidation of a fuel and oxygen in the presence of heat usually with the production of heat, light, and combustion byproducts OXYGEN 21% in air Does not burn - Supports combustion
More informationIMR EX610. Portable Gas Detector. Operation Manual
IMR EX610 Portable Gas Detector Operation Manual IMR Environmental Equipment, Inc. 3634 Central Ave. St. Petersburg, FL 33711 Phone: 727-328-2818 email: info@imrusa.com Read this manual carefully before
More informationExDetector HC-100. Data Sheet. Gas Measuring and Alarm Systems
HC-100 Gas Measuring and Alarm Systems HC-100 Application / Construction The HC100 series of measuring probes, used in conjunction with evaluation systems, have the following functions: Measurement and
More informationNATIONAL STANDARD OF THE PEOPLE'S REPUBLIC OF CHINA. Code for Design of electrical installation For explosive and fire hazardous Atmospheres
UDC NATIONAL STANDARD OF THE PEOPLE'S REPUBLIC OF CHINA 9=t ~A ~~lrl 00 00 *tti\il Code for Design of electrical installation For explosive and fire hazardous Atmospheres ~~~*~~~~~~n~~~*~~ GB 50058-92
More informationSafe Operation Manual. Honeywell IQ Force Gas Detector
Safe Operation Manual Honeywell IQ Force Gas Detector Honeywell Analytics 800-663-4164 403-248-9226 Fax 403-575-3708 03JUN2012 P/N 50105843-047 Version 01 http://www.honeywell.com HONEYWELL IQ Force PERSONAL
More informationARTICLE 25. FUEL GAS CODE
ARTICLE 25. Rule 1. Indiana Fuel Gas Code, 2003 Edition (Repealed) (Repealed by Fire Prevention and Building Safety Commission; filed Mar 18, 2008, 2:32 p.m.: 20080423-IR-675070479FRA, eff 90 days after
More informationCarbon Monoxide (CO) Gas Detector March 15 GCO 300
GCO Carbon Monoxide (CO) Gas Detector March 15 Features Output 4-20 ma or 2-10 Vdc Power supply 24 Vdc Ranges 0-100 ppm or 0-300 ppm IP65 enclosure with quick locking screws Digital measurement value processing
More informationXgard. Fixed detectors For flammable, toxic or oxygen gases
Fixed detectors For flammable, toxic or oxygen gases Xgard Xgard Type 1: Xgard Type 2: Xgard Type 3: Xgard Type 4: Xgard Type 5: Xgard Type 6: Xsafe: Intrinsically safe toxic and oxygen gas detector Flameproof
More information5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors
Ultima X Series Gas Monitors Versatile fixed instruments provide continuous monitoring of many hazardous gases using catalytic, electrochemical, and infrared gas detection methods. HART Protocol is now
More informationSieger Apex. Flexibility that meets your requirements
Sieger Apex Flexibility that meets your requirements Sieger Apex Easy to Install Sensor can be remotely mounted up to 100m from the transmitter On board relays allow for local audible/ visual alarms Strong
More informationGB/T Translated English of Chinese Standard: GB/T NATIONAL STANDARD OF THE
Translated English of Chinese Standard: GB/T8685-2008 www.chinesestandard.net Sales@ChineseStandard.net GB NATIONAL STANDARD OF THE PEOPLE S REPUBLIC OF CHINA ICS 59.080.01 W 04 GB/T 8685-2008 Replacing
More informationALTAIR 5X Multigas Detector Product Specification
ALTAIR 5X Multigas Detector Product Specification PHYSICAL CHARACTERISTICS Gas delivery Size, pumped unit without IR Size, pumped unit with IR Weight Handling Case material Environmental protection Display
More informationSelf-contained and intrinsically safe wireless stand-alone multi-point gas detector.
Introduction United Safety applies the detection system as a multi-point monitoring for toxic gases, combustibles and oxygen hazards. Self-powered and solar-capable, the features unequaled versatility,
More informationAPPLICATION DATA SHEET
APPLICATION DATA SHEET S p e c i f i c a t i o n WWW.-..UK Control Systems Transmitters Sensors Accessories TOCSIN 700 D e t e c t o r C o n t r o l P a n e l Wall mounting 24V DC or 110/230vAC operation
More informationMonitores Personales. Personal Monitor
Monitores Personales Personal Monitor Micro IV Full Featured Personal Monitor Micro IV Single-gas Detector Highly configurable smart sensor design Wide range of sensors including O 2, H 2 S, CO, NH 3,
More informationAustralian/New Zealand Standard
AS/NZS 61779.6:2000 (Incorporating Amendment No. 1) AS/NZS 61779.6:2000 Australian/New Zealand Standard Electrical apparatus for the detection and measurement of flammable gases Part 6: Guide for the selection,
More informationSieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required
Sieger Sensepoint The Sensepoint range of flammable, toxic and oxygen gas detectors offer users a high quality, low cost solution to their industrial gas monitoring needs. Sieger Sensepoint Fit For Purpose
More informationSPECIFICATION MODEL 5200 GAS MONITOR SYSTEM. User Instructions For The Model 5200 Gas Monitor System
SPECIFICATION MODEL 5200 GAS MONITOR SYSTEM User Instructions For The Model 5200 Gas Monitor System To completely customize the specifications to your exact application, modifications to the following
More informationElectrochemical DrägerSensor Sensors for Fixed Gas Detectors
Electrochemical DrägerSensor Sensors for Fixed Gas Detectors Fast response, high accuracy, great stability, long life. Electrochemical DrägerSensors offer all these benefits. You can use the robust and
More informationGasSens. Self Checking Gas Sensors. Modular Gas Detector... Gas & Range Availability
GasSens Modular Gas Detector... Self Checking Gas Sensors GasSens is a flexible component system providing a variety of options to meet individual gas detection and alarm requirements. From chemical and
More informationDräger X-am 5600 Personal Monitor Multi-Gas Detection Device
Dräger X-am 5600 Personal Monitor Multi-Gas Detection Device Featuring an ergonomic design and innovative infrared sensor technology, the Dräger X-am 5600 is the smallest gas detection instrument for the
More informationESD3000 ESD200 Combustible / Toxic Gas Detector
ESD3000 ESD200 Combustible / Toxic Gas Detector Combustible and toxic gas leakage inspection instrument in industrial application Ex-proof certificate Exd ⅡC T6 Gb/Ex d ib ⅡC T6 Gb Dust Ex-proof certificate
More informationMODEL: SP12C7. (Portable 4 gas detector) Operating Manual
MODEL: SP12C7 (Portable 4 gas detector) Operating Manual Guarantee and Repair Senko Co., Ltd. guarantees the products of SP series for 24 months from the shipping date and repairs or replaces the defected
More informationSIL 2. Ultima X Series Gas Monitors CERTIFIED
Ultima X Series Gas Monitors 5 Now with SIL 2 CERTIFIED Products Versatile fixed instruments provide continuous monitoring of many hazardous gases using catalytic, electrochemical, and infrared gas detection
More informationSAFESITE Multi-Threat Detection System
SAFESITE Multi-Threat Detection System The SAFESITE Multi-Threat Detection System simultaneously monitors and wirelessly communicates six potential threats: CWAs, VOCs, TICs, gamma radiation, combustible
More informationGB/T Translated English of Chinese Standard: GB/T
Translated English of Chinese Standard: GB/T8629-2001 www.chinesestandard.net Sales@ChineseStandard.net GB ICS 59.080.01 W 04 National Standard of the People s Republic of China GB/T 8629-2001 eqv ISO
More informationSelecting Gas Detectors for Confined Space Entries
Selecting Gas Detectors for Confined Space Entries Without proper gas detection, hazardous atmospheres may significantly affect the health of an entry team. Many airborne contaminants cannot be detected
More informationSignalpoint. The Signalpoint range of flammable, toxic and Oxygen gas detectors offer users a low cost solution to their indoor gas monitoring needs
Signalpoint The Signalpoint range of flammable, toxic and Oxygen gas detectors offer users a low cost solution to their indoor gas monitoring needs Signalpoint One-Stop Shop Flammable, toxic and Oxygen
More informationLaser Cutting Machine Safety Guide (For employers and employees)
Laser Cutting Machine Safety Guide (For employers and employees) This safety guide is an English translation of Japanese safety guide based on Japanese laws and regulations. Please comply with your country's
More informationThermo Scientific TVA2020 Introduction
Thermo Scientific TVA2020 Introduction The Thermo ScientificT TVA2020 Toxic Vapor Analyzer, is an advanced design, portable, organic/inorganic vapor monitor for the gas survey industry. The analyzer uses
More informationMaterial Safety Data Sheet SECTION 1: PRODUCT AND COMPANY IDENTIFICATION SECTION 2: INGREDIENTS SECTION 3: HAZARDS IDENTIFICATION
Material Safety Data Sheet Copyright, 2009, 3M Company. All rights reserved. Copying and/or downloading of this information for the purpose of properly utilizing 3M products is allowed provided that: (1)
More informationFlammable and Toxic Gas Detection
Your partner in safety Copyright reserved. Specifications and designs are subject to change without prior notice Focused Photonics (HangZhou) Inc. FPI Company Profile Content Focused Photonic Inc. (also
More informationGB Translated English of Chinese Standard: GB
Translated English of Chinese Standard: GB25991-2010 www.chinesestandard.net Sales@ChineseStandard.net GB ICS 43.040.20 T 38 NATIONAL STANDARD OF THE PEOPLE S REPUBLIC OF CHINA GB 25991-2010 Automotive
More informationGAS DETECTOR ST400EC PART.NO
DATA SHEET 1(7) GAS DETECTOR ST400EC PART.NO. 004461-004467 DETECTION OF TOXIC GASES AND OXYGEN SYSTEM GS5000, GS3000, SW2020, BUCONTROL / BUTOUCH GENERAL DESCRIPTION Detection of toxic gases and Oxygen
More informationULTIMA XL/XT Series Gas Monitors. [ Ultimate Features Extreme Design ]
ULTIMA XL/XT Series Gas Monitors [ Ultimate Features Extreme Design ] Cost effective fixed installation gas monitors with HART Field Communications Protocol. Single-sensor units use catalytic, electrochemical
More informationKAB Gas Alarm Operation Manual
KAB Gas Alarm Operation Manual Henan Hanwei Electronics Co.,Ltd ISO9001-2008 Precautions: To avoid personal safety injury, Instrument damage and potential dangerous accident; do not use gas detector before
More informationApplication Note. Gas Turbines. Introduction. Market Segments
Gas Turbines Introduction Beside aircraft types there is a wide range of industrial applications for gas turbine devices. They are used to drive rotating equipment such as compressors at gas pipelines
More informationBST-MG07 Multi-gas Detecting Alarm Manual Instruction
BST-MG7 Multi-gas Detecting Alarm Manual Instruction 1. Application This BST-MG7 multi gas detecting alarm is applied to underground coal mine, petrochemical industry, municipal, environmental protection
More informationALTAIR 5X Multigas Detector
ALTAIR 5X Multigas Detector With MSA XCell Sensor Technology IT S WHAT S INSIDE THAT COUNTS Now with advanced PID for VOC Detection Because every life has a purpose IT S WHAT S INSIDE THAT COUNTS WORKERS
More informationMultiRAE Lite. Wireless Portable Multi-Gas Monitor
MultiRAE Lite Wireless Portable Multi-Gas Monitor The MultiRAE Lite is an optimal one-to-six 4 -gas monitoring solution for personal protection (including confined space entry) and multi-gas leak detection
More informationPortable Instrument Application Guide
Portable Instrument Application Guide Which Portable Gas Detector for which Industry/Application Because every life has a purpose... Gas Detection Instruments Advanced Technology Advanced technology employed
More informationup to 1.2 m or 3.9 ft. deep). So if you drop the Honeywell BW Ultra in a vat or take it into a dust-prone environment,
BW ULTRA User-Friendly Portable Five-Gas Detection in Confined Spaces Designed specifically for sampling and monitoring confined spaces, before and after entry, Honeywell BW Ultra offers enhanced sensor
More informationMODEL: SP12C7. (Portable 4 gas detector) Operating Manual
MODEL: SP12C7 (Portable 4 gas detector) Operating Manual Guarantee and Repair Senko Co., Ltd. guarantees the products of SP series for 24 months from the shipping date and repairs or replaces the defected
More informationMacurco HD-11 Hydrogen Gas Detector
Macurco HD-11 Hydrogen Gas Detector User Instructions Important: Keep these User Instructions for reference TABLE OF CONTENTS GENERAL SAFETY INFORMATION 3 Intended Use 3 List of Warnings and Cautions 3
More informationMacurco HD-11 Hydrogen Gas Detector User Instructions. Important: Keep these User Instructions for reference
Macurco HD-11 Hydrogen Gas Detector User Instructions Important: Keep these User Instructions for reference 2 TABLE OF CONTENTS GENERAL SAFETY INFORMATION 4 INTENDED USE 4 LIST OF WARNINGS AND CAUTIONS
More informationIMR IX176 Portable Gas Detector User Manual
IMR Portable Gas Detector User Manual Read this manual carefully before using this device. (727) 328-2818 / (800) RING-IMR Fax: (727) 328-2826 www.imrusa.com Ver. 1.0A4 CONTENTS SERVICE GUIDELINES... 3
More informationSieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required
Sieger Sensepoint The Sensepoint range of flammable, toxic and oxygen gas detectors offer users a high quality, low cost solution to their industrial gas monitoring needs. Sieger Sensepoint Fit For Purpose
More informationDräger X-am 2500 Multi-Gas Detection
Dräger X-am 2500 Multi-Gas Detection The Dräger X-am 2500 was especially developed for use as personal protection. The 1 to 4 gas detector reliably detects combustible gases and vapours, as well as O2,
More informationa. CFCs. b. HCFCs. c. Pressurized nitrogen. d. Compressed dry air. 17. The state of the refrigerant leaving the condenser of a refrigeration system
Core 1. Ozone in the stratosphere above the earth consists of: a. Molecules containing 3 oxygen atoms. b. Molecules of 2 oxygen atoms. c. Radioactive particles. d. Pollutants that have risen from ground
More informationInstruction Manual Model GX-82 Portable Three Gas Monitor
Instruction Manual Model GX-82 Portable Three Gas Monitor Part Number: 71-0000RK Edition: Second Released: November 1997 RKI Instruments, Inc. 33248 Central Ave. Union City, CA 94587 (510) 441-5656 Warranty
More informationModel GD Instruction Manual. Combustible Gas Leak Detector. reedinstruments. www. com
Model GD-3300 Combustible Gas Leak Detector Instruction Manual reedinstruments com Introduction The Combustible Gas Leak Detector has a 16 gooseneck probe to find leaks in hard-to-reach areas. It s adjustable
More informationSERIES 47K GAS SENSOR
Data Sheet SERIES 47K GAS SENSOR Remote Combustible Gas Detection Supplied by.com Call us on +44 (0)118 916 9420 Email info@247able.com Series 47K Gas Sensor Remote Combustible Gas Detection MSA remote
More informationIGD.CO.UK
APPLICATION DATA SHEET S p e c i f i c a t i o n 2 SO22 WWW.-..UK Control Systems Transmitters Sensors Accessories TOCSIN 700+ D e t e c t o r Website: C o n t r o l P a n e l - Wall mounting or 19 Rack
More informationExplosion protection Marijan Gorše, dipl. ing.
Explosion protection Marijan Gorše, dipl. ing. 1/18 Flammable Gas Atmosphere We Can Control Them Explosion hazards mostly arise from flammable gases and vapours. Instead of avoiding their ignition by explosion
More informationSensepoint. The Sensepoint range of flammable, toxic and oxygen gas detectors offer users a low cost solution to their gas monitoring needs.
Sensepoint The Sensepoint range of flammable, toxic and oxygen gas detectors offer users a low cost solution to their gas monitoring needs. Sensepoint One-Stop Shop Flammable, toxic and oxygen versions
More informationCode for Design of Extinguisher Distribution in Buildings
UDC NATIONAL STANDARD... = ' I: I - p OF THE PEOPLE'S REPUBLIC OF CHINA i:ft *A~~~ IE 00 *fi$1l GB 50140-2005 Code for Design of Extinguisher Distribution in Buildings ltri~:k HIGiiiit~1B Date of issuing:
More informationDräger X-am 5000 Multi-Gas Detection
Dräger X-am 5000 Multi-Gas Detection The Dräger X-am 5000 belongs to a generation of gas detectors, developed especially for personal monitoring applications. This 1- to 5-gas detector reliably measures
More informationREMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS WITH LOCAL DIGITAL DISPLAY
REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS WITH LOCAL DIGITAL DISPLAY FEATURES TXGARD & FLAMGARD PLUS Digital display with flexible output options Wide range of long life sensors Non-intrusive one-man
More informationP R O D U C T D ATA S H E E T
P R O D U C T D T S H E E T www.internationalgasdetectors.com Transmitters Control Systems Sensors ccessories Series Gas Detectors 4-0m Device and 3 Wire ddressable Versions Compact Size EExd Certified
More informationAn easy and flexible way to do gas detection.
An easy and flexible way to do gas detection. 24 Plug-and-Play fieldreplaceable sensors including PID and Infrared options Up to 6 gases monitored simultaneously Optional integral sampling pump with strong
More informationCH 4 C 2 H 2 C 3 H 8 CO 2 H 2 H 2 S HFC NH 3 NO 2 O 2 O 3 SO 2
PluraSens CH 4 C 2 H 2 C 3 H 8 CO CO 2 H 2 H 2 S HFC NH 3 NO 2 O 2 O 3 SO 2 VOC E2600 Family Gas Detectors E2610 Series Compact wall-mount housing providing optimal airflow Integrated sensor with long
More informationOperate the Mutli-Gas Monitor PID
TASK: Operate the Multi-Gas Monitor Learning Objective CONDITION: In a classroom environment, given a fully charged Multi-gas Monitor with the manufacturer operator s manual, all monitor components/accessories,
More informationContent Rev
SASKPOWER RED TAG PROGRAM USER MANUAL Content Rev. 2008-11-17 INDEX Preface 2 Scope 2 Definitions 2 Notification 3 Reporting Procedures 3 Returning the Corrected Red Tag Defect 4 Sample Red Tag (two sided
More informationProperly calibrating catalytic bead sensors: A practical guide
Properly calibrating catalytic bead sensors: A practical guide Catalytic explosives (CatEx) sensors offer precise and reliable detection of flammable gases provided they are optimally set for each detection
More informationSensepoint. Fit For Purpose Flammable, toxic and oxygen versions available High performance, low cost Suitable for new and retro fit applications
Sensepoint The Sensepoint range of flammable, toxic and oxygen gas detectors offer users a high quality, low cost solution to their industrial gas monitoring needs. Sensepoint Fit For Purpose Flammable,
More informationLP GAS LEKAGE ALARM. M. G.. D. D. Wickramasinghe 1*, N. Abhayasinghe 2
- 32 - LP GAS LEKAGE ALARM M. G.. D. D. Wickramasinghe 1*, N. Abhayasinghe 2 1* Corresponding Author, Department of Electronic and Computer Engineering, Sri Lanka Institute of Information Technology (SLIIT),