1 Network(s): Summary: ENGINEERING COMMISSIONING PROCEDURE ECP OPTICAL FIBRE SPLICING, TESTING AND COMMISSIONING REQUIREMENTS EPN, LPN, SPN This standard details the requirements for the splicing, testing and commissioning of site-to-site optical fibre links. Author: David Jeyakumar Approver: Paul Williams Date: 06/08/2018 This document forms part of the Company's Integrated Business System and its requirements are mandatory throughout UK Power Networks. Departure from these requirements may only be taken with the written approval of the Director of Asset Management. If you have any queries about this document please contact the author or owner of the current version. Circulation UK Power Networks External Asset Management UK Power Networks Services Capital Programme Contractors Connections ICPs/IDNOs Health & Safety Meter Operators Legal G81 Website Network Operations Procurement Strategy & Regulation Technical Training THIS IS AN UNCONTROLLED DOCUMENT, THE READER MUST CONFIRM ITS VALIDITY BEFORE USE

2 Revision Record Version 2.0 Review Date 06/08/2023 Date 28/06/2018 Author David Jeyakumar Reason for update: Periodic review What has changed: No content changes Version 1.0 Review Date 31/03/2018 Date 13/12/2016 Author David Jeyakumar New document to cover optical fibre splicing and testing UK Power Networks 2018 All rights reserved 2 of 17

3 Contents 1 Introduction Scope Glossary and Abbreviations Testing Fibre Testing Fibre Identification Testing Prior to Installation Testing After Cabling Testing Following Completion of External Splicing End-to-end Testing Following Completion of Terminations Splicing in External Joints, BFPs and CTPs As-Built Records Commissioning Direct Fibre Links between Hardware Interfaces References National and International Standards Appendix A Workmanship Example Figures Figure 7-1 Example Optical Link Budget from ILM, Transmit and Receive Levels, and Receive Sensitivity... 9 Figure 8-1 Splice Tray Figure 8-2 Splice Tray in a CTP-type ODF Figure 8-3 OPGW-UG Terminal Tower Splice Tray Figure 8-4 Underground Straight 24-fibre Joint Splice Tray Figure 8-5 Patching Side of ODF-type Wall Box Figure 8-6 Termination side of ODF-type Wall Box Figure 8-7 Wall Box with Protective Cassette Covers UK Power Networks 2018 All rights reserved 3 of 17

4 1 Introduction This document details the splicing, testing, commissioning and recording requirements for site-to-site optical fibre links. Along with copper cables and wireless communication solutions, optical fibre links are part of the communications system operated by UK Power Networks for control, monitoring, and protection of the electrical network. Splicing, testing, commissioning, and provision of records, are all important activities in the delivery and hand-over of optical fibre links prior to use for the above critical functions. 2 Scope This document applies wherever splicing, or testing, or commissioning is carried out by a UK Power Networks supplier or contractor as part of the delivery of optical fibre installations. 3 Glossary and Abbreviations Term BFP CTP ILM Microbend Macrobend ODF OTDR SOR TIA TRC Definition Building Flexibility Point Customer Terminal Panel Insertion Loss Measurement An imperfection in the optical fibre, created during manufacture, which is not visible to the naked eye, and which can cause reduction of transmitted optical power. A large visible bend in the optical fibre which is caused by poor handling or installation, and which can cause reduction of transmitted optical power. Optical Distribution Frame Optical Time-Domain Reflectometer An electronic file extension for OTDR trace files traces Telecommunications Industry Association, a body that develops voluntary, consensus-based industry standards for a wide variety of Information and Communication Technologies (ICT) products. An electronic file extension for OTDR trace files traces UK Power Networks 2018 All rights reserved 4 of 17

5 4 Testing 4.1 Fibre Testing The fibre installation process involves several tests. These are summarised in Table 4-1 below, and their application at the various stages of delivery are given in Sections 4.3 to 4.6. Table 4-1 Optical Fibre Tests Test Type Results Format Drum Test End to End OTDR Test End to End ILM Test Splice exception sheet OTDR at 1550nm All Fibres OTDR test at 1310nm and 1550nm All fibres ILM at 1310nm and 1550nm All Fibres OTDR results for each location with bidirectional average losses above 0.05dB SOR or TRC files plus pdf copies showing both distance and attenuation axes zoomed-in to a well-defined scale SOR or TRC files plus pdf copies showing both distance and attenuation axes zoomed-in to a well-defined scale Spreadsheet identifying location, cable and fibre number (if the supplier is not required to terminate the fibres within substations, then recording of loss measurements is not required, however a continuity test shall still be performed in order to prove that fibres are correctly spliced, i.e. there are no crosses) Spreadsheet identifying location, cable and fibre number of the exceptional events. These are splice events that are discussed under section 4.5 (i.e. after three splicing attempts) 4.2 Fibre Identification Optical fibre cables typically consist of elements stranded around a central strength member. Some of the elements are tubes which contain the fibre optic cores. A single tube shall not contain more than 12 fibres. Document TIA-598-D defines a colour code for the cores in each tube, and this is set out in Table 4-2. Table 4-2 Optical Fibre Identification Fibre Colour Fibre Colour 1 Blue 7 Red 2 Orange 8 Black 3 Green 9 Yellow 4 Brown 10 Violet 5 Slate 11 Rose 6 White 12 Aqua UK Power Networks 2018 All rights reserved 5 of 17

6 4.3 Testing Prior to Installation Once the cable drum has been delivered, Drum Tests at 1550nm on each fibre from the cable end on the outside of the drum shall be taken to ensure that there is no damage prior to installation (see Table 4-1 for test details). Testing at the 1550nm wavelength will show up any microbends from the manufacturing process. UK Power Networks reserve the right to witness these tests. The testing party shall inform UK Power Networks of any cable damage identified. 4.4 Testing After Cabling After the cable is installed but before any route splicing occurs, OTDR tests shall be carried out on each fibre length in one direction to ensure that there is no damage during installation. These tests shall be carried out at 1550nm to check for macrobends or breaks caused by cabling damage and the results shall be presented to UK Power Networks. These tests are identical to the Drum Tests (see Table 4-1 for test details). 4.5 Testing Following Completion of External Splicing After the route splicing is complete and cable ends have been pulled into UK Power Networks buildings, the contractor shall record bidirectional End to End OTDR test readings from bare fibre ends for each fibre at both 1310nm and 1550nm (see Table 4-1 for test details). Any splices exceeding the average bidirectional maximum limit shall be re-spliced. If the maximum limit cannot be achieved, then the lowest possible attenuation level shall be accepted with evidence of three re-splicing attempts (at the discretion of the UK Power Networks Operational Telecoms representative) as long as the overall (end to end) loss is within the specification for that fibre. The contractor shall also use optical loss sets (light source and power meter) to identify each fibre from bare-end to bare-end to ensure that there are no crossed fibres or tubes. ILMs are not required to be recorded at this stage because the fibres are not terminated. If accessing any splice enclosures in the future is likely to be difficult, (i.e. for remedial splicing work) then the contractor shall provide a testing engineer at one of the cable end locations, to OTDR test through all fibres real time as the splicing is carried out. Table Acceptable Splice and Connector Losses Parameter Max Value Limitations Bidirectional Splice Loss 0.05dB Connector Loss 0.5dB Per connector Where not possible, i.e. due to fibre manufacture anomalies, three attempts shall be made to meet this criteria and evidence of these attempts shall be recorded as OTDR traces and presented to UK Power Networks with the final test results As-Built pack. 4.6 End-to-end Testing Following Completion of Terminations UK Power Networks Operational Telecoms representatives or their approved contractors shall carry out termination works of all fibre cables within UK Power Networks buildings. This shall include the internal cabling, mounting of fibre wall boxes, installation of cabinet and ODFs etc. On completion of all satisfactory splicing and testing; End to End OTDR and End to End ILMs shall be carried out at both 1310nm and1550nm from the ODF panels (see Table 4-1 for test details). The results shall be recorded and presented to UK Power Networks Operational Telecoms for evaluation and comparison with those provided by the installation Contractor. For generation connections (e.g. photovoltaic farms and wind farms) where the same contractor is responsible for external splicing and internal terminations, the testing activities described in Section 4.5 may be carried out from the ODFs rather than bare-end fibres. UK Power Networks 2018 All rights reserved 6 of 17

7 5 Splicing in External Joints, BFPs and CTPs All fibres shall be straight spliced in joints unless instructions from UK Power Networks state otherwise. Fibres shall be unravelled, cleaned and degreased using suitable spirit and talcum powder to ensure that individual fibres move freely within the splice tray, i.e. they do not stick together. This will ensure that spare fibres can be worked on in the future without causing bends to live fibres. Each tube shall be spliced in a separate tray. Fibres shall be pre-measured in splice trays with sufficient length to ensure that they are stored neatly. Only re-spliced fibres (due to remedial work) should be shorter than the others, but loops of fibre should provide compensation for the reduced length. Note that cable tubes are brittle and susceptible to kinking, and shall therefore be stripped back to protrude no more than 40mm beyond the cable butt. Transport tubing shall then be used between the cable tube and splice tray, and dressed around the inside of the enclosure to allow a reasonable amount of fibre slack. The transport tubing shall be a secure and tight fit over the cable tubes and be suitably restrained at the splice tray with two cable ties. The cable ties shall be filed back to ensure that there are no sharp edges after removal of the excess. Refer to Appendix A for examples. 6 As-Built Records In addition to the OTDR trace files and ILMs, the contractor shall provide photographs of each splice enclosure with close ups of the splice trays using a macro camera setting so that the quality of fibre preparation and splicing work is clearly visible. Further photographs of the splice enclosure fitted in a splice chamber, or on a tower (with the tower reference number) shall also be submitted to verify that the close up is of the correct enclosure. The contractor shall also provide a spreadsheet showing the optical distance (from substation in both directions) to each splice location and its underground or overhead location, i.e. splice chamber grid reference and OHL tower number. In summary, the following documentation shall be submitted to the UK Power Networks Operational Telecoms representative for acceptance and sign off before the contractor shall be paid. (Note that list is in order of importance). 1. Copies of the splicing and testing contractor s qualifications and certificates. 2. Detailed close-up photographs of each splice tray, enclosure, wall box and ODF. 3. A full set of ILM results in a suitable spreadsheet for each fibre core. 4. OTDR traces in native format and pdf (using a suitably detailed scale). 5. A splice exception sheet. 6. Summary sheet showing splice location optical distances. UK Power Networks 2018 All rights reserved 7 of 17

8 7 Commissioning Direct Fibre Links between Hardware Interfaces This section is a guide to connecting systems on to the fibre and ensuring that transceiver link budgets are appropriately considered alongside ILM results. A link from site A to site B is presented on ODFs at each end and fibre patch cords are run to the hardware interfaces at each end. 1. At site A; inspect and clean the fibre patch cord; preferably with a Cletop Cassette Cleaner or similar product. Also, clean the ODF and equipment fibre ports using a one click type connector cleaner. Then connect the patch cord to the transmit port of the local device. Connect the other end of the same patch cord to an optical power meter, then measure and record the received level. Remove the connector from the optical power meter and connect it to the ODF on the assigned port. 2. At site B; inspect and clean the fibre patch cord (as previously described) and connect it to the ODF on the corresponding fibre port. Connect the other end to an optical power meter and measure and record the received level. This is the level that the local device at B will receive from the transmitter at site A. Then connect the patch cord to the receiver of the unit at site B. 3. Carry out the same procedure for the link transmitting from B to A. Ensure that these measurements are compatible with the ILM readings (measured in db) by subtracting the receive level from the transmit level (measured in dbm) in each case, including the additional connector losses. The ILM readings will include connector losses and different patch leads will vary this value by a generally insignificant extent, as long as the connectors are kept scrupulously clean. An example is shown in Figure 7-1A transceiver transmit level of -6dBm over a fibre with an ILM reading of 5dB should give a receive reading of -11dBm at the receive end ODF. In this case, the manufacturer s specified receive sensitivity for the equipment transceiver shall be at least 5dB lower than -11dBm. If this sensitivity is -16dBm, then the link is working with 5dB of spare optical budget when receiving a level of -11dBm. This spare 5dB will allow fluctuations in link budget caused by bending patch leads or fibres in cassette trays without failure of the system. UK Power Networks 2018 All rights reserved 8 of 17

9 Transmit level of -6dBm (measured at ODF) An ILM reading of 5dB from ODF to ODF -11 dbm received here -6 dbm received here Result: A spare optical budget of 5dB. Receive sensitivity of transceiver is -16dBm Figure 7-1 Example Optical Link Budget from ILM, Transmit and Receive Levels, and Receive Sensitivity UK Power Networks 2018 All rights reserved 9 of 17

10 8 References 8.1 National and International Standards TIA-598-D Optical Fiber Cable Color Coding UK Power Networks 2018 All rights reserved 10 of 17

11 Appendix A Workmanship Example The photos in this section show the expected quality of workmanship typically required by UK Power Networks. Photographs submitted with as-built records shall show a similarly detailed level of the subject matter. Annotated close up of a splice tray showing fibre lengths accurately measured to avoid macrobends and untidy loops. Transport tubing is securely fixed as it enters the cassette. Figure 8-1 Splice Tray UK Power Networks 2018 All rights reserved 11 of 17

12 Close up of splice tray in a CTP-type ODF. Pigtail fibre lengths are accurately measured to avoid macrobends and untidy loops are securely stored in the cassette. Figure 8-2 Splice Tray in a CTP-type ODF UK Power Networks 2018 All rights reserved 12 of 17

13 Close up of splice tray in an overhead OPGW to underground fibre joint on a terminal tower. Fibre lengths are accurately measured to avoid macrobends and untidy loops. Due to the large cassette size, a greater length of slack can be stored to allow remedial splicing. Figure 8-3 OPGW-UG Terminal Tower Splice Tray UK Power Networks 2018 All rights reserved 13 of 17

14 Close up of splice tray in an underground straight 24 fibre joint. The cassette has an additional spooling area so that a greater length of slack can be stored to allow remedial splicing. Figure 8-4 Underground Straight 24-fibre Joint Splice Tray UK Power Networks 2018 All rights reserved 14 of 17

15 Close up of an ODF-type wall box, typically for use in a generation site. The box has two sections; this is the patching side. Figure 8-5 Patching Side of ODF-type Wall Box UK Power Networks 2018 All rights reserved 15 of 17

16 Close up of an ODF-type wall box, typically for use in a generation site. The box has two sections; this is the side used to terminate the external cable on to pigtails. Note that the cable strength member is terminated at the top to prevent the cable being accidentally pulled through the gland. Figure 8-6 Termination side of ODF-type Wall Box UK Power Networks 2018 All rights reserved 16 of 17

17 This is the same wall box shown in figure 5 but with the cassette covers fitted to protect the splices Figure 8-7 Wall Box with Protective Cassette Covers UK Power Networks 2018 All rights reserved 17 of 17

NSP/002/001 Guidance document for the installation of Fibre Optic Underground Cables

NSP/002/001 Guidance document for the installation of Fibre Optic Underground Cables Version: 2.0 Date of Issue: Aug 2015 Page: 1 of 15 NSP/002/001 Guidance document for the installation of Fibre Optic Underground Cables 1. Purpose The purpose of this document is to provide guidance on

More information

Ensuring Cabling Performance in the Customer-Owned Outside Plant

Ensuring Cabling Performance in the Customer-Owned Outside Plant Ensuring Cabling Performance in the Customer-Owned Outside Plant Needs to be able to qualify the installation to validate bandwidth requirements are met Future high bandwidth applications Future Proof

More information

A. General: Horizontal and backbone cabling shall be verified in accordance with ANSI/TIA/EIA-568-C and the addendum for fiber optic testing.

A. General: Horizontal and backbone cabling shall be verified in accordance with ANSI/TIA/EIA-568-C and the addendum for fiber optic testing. 3.4 TESTING OF FIBER OPTICS CABLING A. General: Horizontal and backbone cabling shall be verified in accordance with ANSI/TIA/EIA-568-C and the addendum for fiber optic testing. B. General: In the event

More information

STANDARD TEST PROCEDURE PRE-TEST QUALITY OF OPTIC FIBRE CABLE ON DRUMS TYPE OF CABLE :

STANDARD TEST PROCEDURE PRE-TEST QUALITY OF OPTIC FIBRE CABLE ON DRUMS TYPE OF CABLE : PROCEDURE PRE-TEST QUALITY OF OPTIC FIBRE CABLE ON DRUMS STANDARD TEST PROCEDURE PRE-TEST QUALITY OF OPTIC FIBRE CABLE ON DRUMS TYPE OF CABLE : 1) SINGLE MODE 2) MULTI-MODE IN EXCESS OF 100 METRES PRC-00107

More information

Special Provision No. 683S28 December 2017

Special Provision No. 683S28 December 2017 FIBRE OPTIC COMMUNICATION CABLES, AERIAL ON MESSENGER CABLE - Item No. FIBRE OPTIC COMMUNICATION CABLES, AERIAL ON MESSENGER CABLE (TEMPORARY) - Item No. Special Provision No. 683S28 December 2017 1. SCOPE

More information

Ensuring Cabling Performance in the Customer-Owned Outside Plant. Keith Foord Product Manager Greenlee Communications

Ensuring Cabling Performance in the Customer-Owned Outside Plant. Keith Foord Product Manager Greenlee Communications Ensuring Cabling Performance in the Customer-Owned Outside Plant Keith Foord Product Manager Greenlee Communications Introduction: Outside plant fiber networks require low reflectance terminations for

More information

SECTION TESTING OF FIBER OPTIC CABLES

SECTION TESTING OF FIBER OPTIC CABLES PART 1 GENERAL 1.01 DESCRIPTION A. The work covered by this section of the Specifications includes all labor necessary to perform and complete such construction, all materials and equipment incorporated

More information

Jan07 Rev B

Jan07 Rev B Qualification Test Report 501-545 05Jan07 Rev B MT-RJ Patch Panel and Outlet Jacks (Standard, XG, SECURE and SECURE XG) 1. INTRODUCTION 1.1. Purpose Testing was performed on Tyco Electronics MT-RJ Jack,

More information

SECTION TESTING OF FIBER OPTIC CABLES

SECTION TESTING OF FIBER OPTIC CABLES SECTION 27 08 23 TESTING OF FIBER OPTIC CABLES PART 1 GENERAL 1.01 DESCRIPTION A. The work covered by this section of the Specifications includes all labor necessary to perform and complete such construction,

More information

STATE OF NEW JERSEY DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY SPECIFICATIONS FOR FUSION SPLICE AND SPLICE ENCLOSURE FIBER OPTIC CABLE

STATE OF NEW JERSEY DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY SPECIFICATIONS FOR FUSION SPLICE AND SPLICE ENCLOSURE FIBER OPTIC CABLE STATE OF NEW JERSEY DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY 08625 SPECIFICATIONS FOR FUSION SPLICE AND SPLICE ENCLOSURE FIBER OPTIC CABLE N.J. Specification No. Effective Date: July 1, 2001 New

More information

2016 CDM Smith All Rights Reserved July 2016 SECTION FIBER OPTIC DATA NETWORK

2016 CDM Smith All Rights Reserved July 2016 SECTION FIBER OPTIC DATA NETWORK PART 1 GENERAL 1.01 SCOPE OF WORK SECTION 27 12 23 FIBER OPTIC DATA NETWORK A. Furnish, install, terminate, and test all fiber optic equipment and cabling necessary for a complete and functional data highway

More information

Fibre Characterisation and FTTx New challenges

Fibre Characterisation and FTTx New challenges Fibre Characterisation and FTTx New challenges Broadband Technology Event Rotterdam, November 10th, 2009 Nicolas CARLIER France & Benelux RSM nicolas.carlier@exfo.com What is Fiber Characterisation when

More information

Fibre (TIA) Field Test Specification

Fibre (TIA) Field Test Specification This document has been prepared to aid consultants or engineers in developing contractual specifications covering the testing of duplex fibre optic cabling installations. It is offered as a general guide.

More information

The Rise of Tier 2 Testing

The Rise of Tier 2 Testing The Rise of Tier 2 Testing Why enterprises today demand better visibility into their fiber infrastructure Unprecedented demand for more bandwidth, faster network speeds, lower latency, and improved data

More information

Field Test Procedure for Optical Fibre Link Measurements

Field Test Procedure for Optical Fibre Link Measurements Application Notes Field Test Procedure for Optical Fibre Link Measurements Issued April 2014 Abstract After fiber optic cables are installed, spliced and terminated, they must be tested. For every fiber

More information

FLX380-30x FlexTester OTDR

FLX380-30x FlexTester OTDR Features 3rd generation hand-held, all-in-one OTDR, Source, Power Meter, VFL Icon-based LinkMap display with pass/fail for easy network analysis Patented in- or out-of-service testing from a single port

More information

Fibre Specification Standards

Fibre Specification Standards Fibre Specification Standards User Manual The most important thing we build is trust Cobham Wireless - Coverage Table of Contents 1. Single-mode Fibre to ITU-T Recommendation G.652 3 2. SC/APC Mated Pair

More information

HELKAMA. Optical Fibre Cables

HELKAMA. Optical Fibre Cables 1 Contents Optical fibres and their characteristics Cable constructions Cable tests Installation, jointing and terminating Manufacturing (pictures) 2 Multimode Fibre (GK) Attenuation and Bandwidth Fibre

More information

VTI Services Technical Bulletin (TB) OTDR Measurement of Installed Optical Fibre Cabling Permanent Links and Links

VTI Services Technical Bulletin (TB) OTDR Measurement of Installed Optical Fibre Cabling Permanent Links and Links VTI Services Technical Bulletin (TB) OTDR Measurement of Installed Optical Fibre Cabling Permanent Links and Links TB Number 004 This bulletin is supplied for information only and is intended to provide

More information

OPTICAL TIME-DOMAIN REFLECTOMETER

OPTICAL TIME-DOMAIN REFLECTOMETER Tallinn University of Technology Laboratory exercise 1 of Fiber Optical Communication course OPTICAL TIME-DOMAIN REFLECTOMETER Tallinn 2016 Aim of the laboratory exercise: The aim of this laboratory exercise

More information

Field Testing and Troubleshooting of PON LAN Networks per IEC Jim Davis Regional Marketing Engineer Fluke Networks

Field Testing and Troubleshooting of PON LAN Networks per IEC Jim Davis Regional Marketing Engineer Fluke Networks Field Testing and Troubleshooting of PON LAN Networks per IEC 61280-4 Jim Davis Regional Marketing Engineer Fluke Networks Agenda Inspection and Cleaning APC vs UPC PON basics Wavelengths Architecture

More information

FTTH NETWORK TESTING: REAL APPLICATIONS USING THE OLTS METHOD

FTTH NETWORK TESTING: REAL APPLICATIONS USING THE OLTS METHOD FTTH NETWORK TESTING: REAL APPLICATIONS USING THE OLTS METHOD 157 APPLICATION NOTE Mario Simard, Product Manager, Optical Business Unit The purpose of any fiber-optic network is to perform high-speed,

More information

FIBRE OPTIC COMMUNICATION CABLES, IN DUCTS - Item No. FIBRE OPTIC COMMUNICATION CABLES, IN DUCTS (TEMPORARY) - Item No.

FIBRE OPTIC COMMUNICATION CABLES, IN DUCTS - Item No. FIBRE OPTIC COMMUNICATION CABLES, IN DUCTS (TEMPORARY) - Item No. FIBRE OPTIC COMMUNICATION CABLES, IN DUCTS - Item No. FIBRE OPTIC COMMUNICATION CABLES, IN DUCTS (TEMPORARY) - Item No. Special Provision No. 683S01 December 2017 1. SCOPE This Special Provision covers

More information

SECTION COMMUNICATIONS FIBER CABINETS, ADAPTERS AND CONNECTORS

SECTION COMMUNICATIONS FIBER CABINETS, ADAPTERS AND CONNECTORS SECTION 27 11 20 COMMUNICATIONS FIBER CABINETS, ADAPTERS AND CONNECTORS PART 1 GENERAL 1.01 DESCRIPTION A. The work covered by this section of the Specifications includes all labor necessary to perform

More information

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE ENGINEERING MITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE 240 2017 SCTE Test Procedures for Testing CWDM Systems in Cable Telecommunications Access Networks NOTICE The Society

More information

INTERNATIONAL TELECOMMUNICATION UNION SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE PLANT

INTERNATIONAL TELECOMMUNICATION UNION SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE PLANT INTERNATIONAL TELECOMMUNICATION UNION ITU-T L.36 TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU (10/98) SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE PLANT

More information

Fiber Optic and CAT 5, 6, 7 and 8 Installer Premise Cabling

Fiber Optic and CAT 5, 6, 7 and 8 Installer Premise Cabling Hands-On Fiber Optic and CAT 5, 6, 7 and 8 Installer Premise Cabling Certification Course Description This Hands-On course is customized to give Technicians the confidence and skills to maintain Fiber

More information

Draft ES V1.1.1 ( )

Draft ES V1.1.1 ( ) Standard Transmission and Multiplexing (TM); Passive optical components; Fibre optic mechanical splices for single-mode optical fibre communications systems; Common requirements and conformance testing

More information

This is a preview - click here to buy the full publication

This is a preview - click here to buy the full publication ISO/IEC 14763-3 CONSOLIDATED VERSION Edition 2.1 2018-08 colour inside Information technology Implementation and operation of customer premises cabling Part 3: Testing of optical fibre cabling INTERNATIONAL

More information

ETSI TS V1.2.1 ( )

ETSI TS V1.2.1 ( ) TS 101 263 V1.2.1 (2004-07) Technical Specification Transmission and Multiplexing (TM); Passive optical components; Fibre optic mechanical splices for single-mode optical fibre communications systems for

More information

NZQA unit standard version 1 Page 1 of 6. Install, maintain and repair of telecommunications optical fibre network infrastructure

NZQA unit standard version 1 Page 1 of 6. Install, maintain and repair of telecommunications optical fibre network infrastructure Page 1 of 6 Title Install, maintain and repair of telecommunications optical fibre network infrastructure Level 3 Credits 25 Purpose This unit standard covers installation, maintenance and repair of telecommunications

More information

RLH Industries, Inc. Cleaning and Testing Fiber Optic Cable. Reference Guide MD A 0507

RLH Industries, Inc. Cleaning and Testing Fiber Optic Cable. Reference Guide MD A 0507 RLH Industries, Inc. Cleaning and Testing Fiber Optic Cable Reference Guide MD-019 2014A 0507 RLH Industries, Inc. Copyright 2013 RLH Industries, Inc. All rights reserved. No part of this document may

More information

Qualification Test Report LightCrimp* Plus Singlemode and Multimode LC Connector (Field Installable)

Qualification Test Report LightCrimp* Plus Singlemode and Multimode LC Connector (Field Installable) Qualification Test Report LightCrimp* Plus Singlemode and Multimode LC Connector (Field Installable) 501-586 26Feb09 Rev F 1. INTRODUCTION 1.1. Purpose Testing was performed on Tyco Electronics LightCrimp*

More information

MT-RJ Optical Fiber System Field Testing

MT-RJ Optical Fiber System Field Testing MT-RJ Optical Fiber System Field Testing Table of Contents INTRODUCTION... 3 TEST JUMPERS... 4 LAUNCH CONDITIONS... 4 MT-RJ TEST KITS... 5 MT-RJ SYSTEM TESTING: Fixed transmit and receive (SC or ST-style)

More information

Reflectance, The Hidden Danger That Increases Bit Error Rates in Your Fiber Networks Denver, May 22nd, 2010

Reflectance, The Hidden Danger That Increases Bit Error Rates in Your Fiber Networks Denver, May 22nd, 2010 Reflectance, The Hidden Danger That Increases Bit Error Rates in Your Fiber Networks Denver, May 22nd, 2010 Adrian Young Sr. Customer Support Engineer Foreword Reflectance is measured using an Optical

More information

LAB REPORT SUBMISSION COVER PAGE ETN4106 OPTOELECTRONICS AND OPTICAL COMMUNICATIONS

LAB REPORT SUBMISSION COVER PAGE ETN4106 OPTOELECTRONICS AND OPTICAL COMMUNICATIONS 1/10 FACULTY OF ENGINEERING LAB REPORT SUBMISSION COVER PAGE ETN4106 OPTOELECTRONICS AND OPTICAL COMMUNICATIONS TRIMESTER 3, SESSION 2016/2017 Student Name: Student ID: Degree Major (please circle): EE

More information

Benefits of Enhanced Event Analysis in. Mark Miller

Benefits of Enhanced Event Analysis in. Mark Miller Benefits of Enhanced Event Analysis in Data Center OTDR Testing Mark Miller Dr. Fang Xu AFL/Noyes Test & Inspection Overview Challenges Topics Techniques and Improvements Benefits of enhanced event analysis

More information

4120 Fire Alarm Network Reference

4120 Fire Alarm Network Reference 4120 Fire Alarm Network Reference Features Autocall 4120 Fire Alarm Network communications are available for wired or fiber optic connections Wired communications are available on Network Interface Cards

More information

Optical Return Loss Measurement by Gregory Lietaert, Product Manager

Optical Return Loss Measurement by Gregory Lietaert, Product Manager White Paper Optical Return Loss Measurement by Gregory Lietaert, Product Manager Introduction With the increasing frequency of high-speed transmission systems and DWDM deployment, optical return loss (ORL)

More information

Acceptance Requirements. Fibre Optic Systems. Revised 12/2017. December 5th, Alexander Kölbel

Acceptance Requirements. Fibre Optic Systems. Revised 12/2017. December 5th, Alexander Kölbel December 5th, 2017 Acceptance Requirements Fibre Optic Systems Revised 12/2017 Alexander Kölbel +49 6190 8880-40 alexander.koelbel@datwyler.com Dätwyler Cables GmbH, Auf der Roos 4-12, 65795 Hattersheim,

More information

Fibre Optic Basics FIA Summer Seminar 2014

Fibre Optic Basics FIA Summer Seminar 2014 Fibre Optic Basics FIA Summer Seminar 2014 Andrew Cole Theory Basics Characteristics of Light What is Light? An electromagnetic wave, which like other waves, has a frequency (f), velocity (v) and a wavelength

More information

Product Specification EMI Shielded Duplex LC Sealed Receptacle (ODVA Conforming)

Product Specification EMI Shielded Duplex LC Sealed Receptacle (ODVA Conforming) Product Specification EMI Shielded Duplex LC Sealed Receptacle (ODVA Conforming) 02Oct08 Rev A 1. SCOPE 1.1. Content This specification, based on IEC 61753-1 Edition 1.0 tests for Category E (Extreme Environment),

More information

M700-Series Multifunction OTDR

M700-Series Multifunction OTDR M700-Series Multifunction OTDR Test, Troubleshoot and Document Single-mode and Multimode Fiber Networks Test Modes Full Auto OTDR Normal (point-to-point) fiber cable construction testing and fault location

More information

OWL. Laser OWL Series. Operations Guide. Singlemode Light Sources. Optical Wavelength Laboratories. Date: October 1, 2015

OWL. Laser OWL Series. Operations Guide. Singlemode Light Sources. Optical Wavelength Laboratories. Date: October 1, 2015 Laser OWL Series Operations Guide Singlemode Light Sources OWL Optical Wavelength Laboratories Operations Guide Laser OWL and Laser OWL HP Singlemode Light Sources Date: October 1, 015 Version.5 Optical

More information

OTDR II. Tier-2 Optical Time Domain Reflectometer for Multimode and Single-mode Fiber Cabling

OTDR II. Tier-2 Optical Time Domain Reflectometer for Multimode and Single-mode Fiber Cabling Tier-2 Optical Time Domain Reflectometer for Multimode and Single-mode Fiber Cabling Tier-2 Optical Time Domain Reflectometer for Multimode and Single-mode Fiber Cabling The OTDR II is the first tablet

More information

Electrical Safety Requirements

Electrical Safety Requirements Electrical Safety Requirements Purpose This document defines the minimum required control measures to reduce the risk of injury or illness related to electricity. Scope Applicable to all Coca-Cola system

More information

Applications Engineering Notes

Applications Engineering Notes Applications Engineering Notes Document Title Document Number Revision Number Product Specification and Qualification Test Report: IBC Brand Fiber Optic Connector Cleaner MT38 II AEN-1146 Issue Effective

More information

Product Information. Optical fibre water sensor. - Early warning system for ensuring maximum availability of optical transmission routes

Product Information. Optical fibre water sensor. - Early warning system for ensuring maximum availability of optical transmission routes C:\Users\Public\Dieter Dokumente\Wolf\Wolf Info\Sensor\Englisch\[WO]-E Water Sensor (Product Product Information Optical fibre water sensor - Early warning system for ensuring maximum availability of optical

More information

OTDR - FHO5000-xxx. Optical Time Domain Reflectometer

OTDR - FHO5000-xxx. Optical Time Domain Reflectometer OTDR - FHO5000-xxx Optical Time Domain Reflectometer FHO5000 series Optical Time Domain Reflectometer (OTDR) is the latest generation of intelligent instrument for test and detection of fiber optic communication

More information

MTTplus Modular Test Platform

MTTplus Modular Test Platform MTTplus-410 Fiber Optics Test Module 2017 MTTplus Modular Test Platform The Fiber Optics module for the VeEX MTTplus supports a full range of test functions including OTDR, OPM, Light Source and VFL. Geo

More information

FACULTY OF ENGINEERING LAB SHEET OPTICAL COMMUNICATION SYSTEMS EOP4066 TRIMESTER 1 (2013/2014)

FACULTY OF ENGINEERING LAB SHEET OPTICAL COMMUNICATION SYSTEMS EOP4066 TRIMESTER 1 (2013/2014) FACULTY OF ENGINEERING LAB SHEET OPTICAL COMMUNICATION SYSTEMS EOP4066 TRIMESTER 1 (2013/2014) OC1 FIBER LINK CHARACTERIZATION WITH OTDR *Note: On-the-spot evaluation may be carried out during or at the

More information

Fiber Optics for Todays Industry Applications

Fiber Optics for Todays Industry Applications Hands-On Fiber Optics for Todays Industry Applications (A Non-Telephone Company Course) Course Description This Hands-On course is designed to provide technicians with a practical understanding and Hands-On

More information

Dome Fiber Optic Closure SC-221

Dome Fiber Optic Closure SC-221 Dome Fiber Optic Closure SC-221 General Information SC-221 fiber optic closure protects the fiber optic splices from harsh external environment conditions. It is designed for many network segments and

More information

Basic Professional Fiber Optic Installation

Basic Professional Fiber Optic Installation Basic Professional Fiber Optic Installation QUICK SUMMARY Length: 32 hours; or 40 hours with Fiber Optic Association CFOT certification Hands-on Activities: 40 activities, 70-75 % Text/Field Reference:

More information

CITY OF AUSTIN ARTERIAL MANAGEMENT DIVISION SPECIFICATIONS FOR THE INSTALLATION AND MAINTENANCE OF SINGLE MODE FIBER OPTIC CABLE

CITY OF AUSTIN ARTERIAL MANAGEMENT DIVISION SPECIFICATIONS FOR THE INSTALLATION AND MAINTENANCE OF SINGLE MODE FIBER OPTIC CABLE 1. INTRODUCTION The City of Austin, hereafter referred to as COA or as the City, and Arterial Management Division of the Austin Transportation Department (ATD) is seeking bids for the installation, termination,

More information

SECTION COMMUNICATIONS OPTICAL FIBER BACKBONE CABLING

SECTION COMMUNICATIONS OPTICAL FIBER BACKBONE CABLING SECTION 27 13 23 COMMUNICATIONS OPTICAL FIBER PART 1 - GENERAL 1.1 SUMMARY A. Section Includes the following: 1. 50/125-micrometer, optical fiber cabling. 2. Cable connecting hardware, termination panels,

More information

The Definitive Handheld OTDR for FTTx Testing OTDR AXS Compact, lightweight handheld OTDR optimized for access/fttx network testing

The Definitive Handheld OTDR for FTTx Testing OTDR AXS Compact, lightweight handheld OTDR optimized for access/fttx network testing * Microsoft ActiveSync Access OTDR Compact, lightweight handheld OTDR optimized for access/fttx network testing Top user-friendliness: one-button testing, combined with EXFO s proprietary FTTx software

More information

Noyes OFL 250B Specs Provided by

Noyes OFL 250B Specs Provided by Noyes OFL 250B Specs Provided by www.aaatesters.com OFL 250 Handheld OTDR The Noyes OFL 250 from AFL Telecommunications is a single-mode OTDR with an integrated Optical Power Meter (OPM), Source (OLS),

More information

Hands-On CAT 5/6 & Fiber Optic Installer

Hands-On CAT 5/6 & Fiber Optic Installer Hands-On BICSI CECs This course has been approved for CEC credits by BICSI. Please read below for a breakdown of the credits that we offer for this course. For more information regarding BICSI please visit

More information

Jul07 Rev C

Jul07 Rev C Product Specification 108-2167 11Jul07 Rev C MPO and MPO SECURE Multimode Fiber Optic Connector and Adapter 1. SCOPE 1.1. Content This specification, which is based on GR-1435-CORE, covers the performance,

More information

Fire Control Panels. Multiple Signal Fiber Optic Modems and Accessories for Panel and Remote Mounting. Features. Operation.

Fire Control Panels. Multiple Signal Fiber Optic Modems and Accessories for Panel and Remote Mounting. Features. Operation. UL, ULC Approved* Fire Control Panels Multiple Signal Fiber Optic Modems and Accessories for Panel and Remote Mounting Features Converts multiple fire alarm communications signals into a single fiber optic

More information

Telephone and Data Structured Wiring

Telephone and Data Structured Wiring Data Specification Category 6A General Telephone and Data Structured Wiring The Electrical Sub-Contractor shall employ a specialist sub-contractor to provide the following systems:- Manufacturer System

More information

SERIES G: TRANSMISSION SYSTEMS AND MEDIA, DIGITAL SYSTEMS AND NETWORKS Transmission media and optical systems characteristics Optical fibre cables

SERIES G: TRANSMISSION SYSTEMS AND MEDIA, DIGITAL SYSTEMS AND NETWORKS Transmission media and optical systems characteristics Optical fibre cables International Telecommunication Union ITU-T TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU G.650.3 (03/2008) SERIES G: TRANSMISSION SYSTEMS AND MEDIA, DIGITAL SYSTEMS AND NETWORKS Transmission media and

More information

ETSI TS V1.2.1 ( )

ETSI TS V1.2.1 ( ) TS 100 783 V1.2.1 (2004-08) Technical Specification Transmission and Multiplexing (TM); Passive optical components; Fibre optic fusion splices for single-mode optical fibre transmission systems for indoor

More information

AS/NZS ISO/IEC :2012

AS/NZS ISO/IEC :2012 AS/NZS ISO/IEC 14763.3:2012 (ISO/IEC 14763-3:2011, MOD) Australian/New Zealand Standard Telecommunications installations Implementation and operation of customer premises cabling Part 3: Testing of optical

More information

Savitri Telecom Services

Savitri Telecom Services +91-8048720208 Savitri Telecom Services https://www.savitritelecomservices.com/ We have strongly marked our name as manufacturers, suppliers, traders and exporters of Electrical and Mechanical Equipments.

More information

GAMMA OTDR application consists of main window and menu. Using menu user can operate in different modes of application.

GAMMA OTDR application consists of main window and menu. Using menu user can operate in different modes of application. GAMMA OTDR Introduction...1 Using GAMMA OTDR...1 Application main window...1 Menu description...2 file...2 instrument...2 mode...5 events...9 view...11 Introduction GAMMA OTDR is the first Android application

More information

iotdr Series Portable OTDR Test Set iotdr Series OTDR Tester is entirely new portable product released by OPWILL.

iotdr Series Portable OTDR Test Set   iotdr Series OTDR Tester is entirely new portable product released by OPWILL. www.opwill.com OTDR Tester is entirely new portable product released by OPWILL. Adopting Bluetooth technology allows engineers to conduct the test remotely on their portable Windows, or Android devices.

More information

Product Specification Qualification Test Report

Product Specification Qualification Test Report PS 88 / DMI PC SM / 6/5 DIAMOND Test & Calibration Laboratory STS 333 / SCS 11 Product Specification Qualification Test Report DMI PC SM DIAMOND SA Via dei Patrizi 5 CH-6616 LOSONE Tel. +41 91 785 45 45

More information

QUALIFICATIONS PACK - OCCUPATIONAL STANDARDS FOR TELECOM INDUSTRY. Introduction Qualifications Pack- Optical Fibre Splicer

QUALIFICATIONS PACK - OCCUPATIONAL STANDARDS FOR TELECOM INDUSTRY. Introduction Qualifications Pack- Optical Fibre Splicer QUALIFICATIONS PACK - OCCUPATIONAL STANDARDS FOR TELECOM INDUSTRY W h a t a r e O c c u p a t i o n a l S t a n d a r d s ( O S )? OS describe what individuals need to do, know and understand in order

More information

Duct Cable GYTS-144B1.3

Duct Cable GYTS-144B1.3 Optical Fibre Cable Technical Specification Duct Cable GYTS-144B1.3 Xcom Ltd All rights reserved 1. Scope This Specification covers the design requirements and performance standard for the supply of optical

More information

Optical Fibre Cable Technical Specification. Duct Cable GYTA-72B1.3

Optical Fibre Cable Technical Specification. Duct Cable GYTA-72B1.3 VersionGYTA-72B1.3 Optical Fibre Cable Technical Specification Duct Cable GYTA-72B1.3 Yangtze Optical Fibre and Cable Joint Stock Limited Company All rights reserved www.yofc.com All Rights Reserved Copyright

More information

FIBRE OPTIC INSTALLATION QUALITY PLAN PRO-FORMA

FIBRE OPTIC INSTALLATION QUALITY PLAN PRO-FORMA FIBRE OPTIC INSTALLATION QUALITY PLAN PRO-FORMA DOCUMENT No: FIA/QPT/1/95 A complete set documentation providing an easy-to-use checklist to allow the development a associated with an Installation Specification

More information

The Optical Time Domain Reflectometry and the Fusion Splicer Laboratory exercise

The Optical Time Domain Reflectometry and the Fusion Splicer Laboratory exercise The Optical Time Domain Reflectometry and the Fusion Splicer Laboratory exercise 1 The purpose of the exercise...2 2 Background...2 2.1 Introduction to scattering and attenuation...2 2.2 Introduction to

More information

FLX380 and OFL280 FlexTester Series

FLX380 and OFL280 FlexTester Series FLX380 and OFL280 FlexTester Series User Guide www.aflglobal.com or +1 (800) 321-5298, +1 (603) 528-7780 Contents Safety Information... 4 General Information... 5 Contacting Customer Service...5 Recommended

More information

Web Pages for Construction and Traveler Information Condition Reporting System 511 Phone Power. Data Processing and Response Formulation

Web Pages for Construction and Traveler Information Condition Reporting System 511 Phone Power. Data Processing and Response Formulation Existing Existing To Be Modified To Be Developed Not Applicable Visual Surveillance (e.g. CCTV) Traffic Detectors (excluding presence detectors at intersections for signal control) Dynamic Message Sign

More information

Link loss measurement uncertainties: OTDR vs. light source power meter By EXFO s Systems Engineering and Research Team

Link loss measurement uncertainties: OTDR vs. light source power meter By EXFO s Systems Engineering and Research Team Link loss measurement uncertainties: OTDR vs. light source power meter By EXFO s Systems Engineering and Research Team INTRODUCTION The OTDR is a very efficient tool for characterizing the elements on

More information

SYSTIMAX 360 Low-Profile, Stackable Splice Tray Kit Instructions

SYSTIMAX 360 Low-Profile, Stackable Splice Tray Kit Instructions Instruction Sheet 860506468 Issue 2, December 2012 SYSTIMAX Solutions SYSTIMAX 360 Low-Profile, Stackable Splice Tray Kit Instructions General The SYSTIMAX 360 LP-STACK-SPT stackable splice tray is 14

More information

4 Channel Contact Closure SFP DIN Fiber Link System

4 Channel Contact Closure SFP DIN Fiber Link System USER GUIDE The leader in rugged fiber optic technology. U- 07A-0707 Channel Contact Closure DIN Fiber Link System Installation and Configuration Information Description The system provides transmission

More information

FIA. The Fibreoptic Industry Association. TECHNICAL SUPPORT GUIDE FIA-TSD

FIA. The Fibreoptic Industry Association.  TECHNICAL SUPPORT GUIDE FIA-TSD FIA The Fibreoptic Industry Association www.fibreoptic.org.uk TECHNICAL SUPPORT GUIDE FIATSD000 TESTING INSTALLED CABLING USING OPTICAL TIME DOMAIN RELFECTOMETER (OTDR) EQUIPMENT This document has been

More information

OTDR. Optical Time Domain Reflectometer. User Guide

OTDR. Optical Time Domain Reflectometer. User Guide OTDR Optical Time Domain Reflectometer User Guide Copyright 2013 2015 EXFO Inc. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system or transmitted in any form,

More information

IDEAL INDUSTRIES, INC. USER MANUAL IDEAL OTDR

IDEAL INDUSTRIES, INC. USER MANUAL IDEAL OTDR IDEAL INDUSTRIES, INC. USER MANUAL IDEAL OTDR Revision: March 31, 2016 Copyright 2013 2016 EXFO Inc. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system or

More information

A Quick Start Guide to Fiber-to-the-Antenna (FTTA) Installation and Maintenance Testing. Vol. 2 Tier 2 Certification

A Quick Start Guide to Fiber-to-the-Antenna (FTTA) Installation and Maintenance Testing. Vol. 2 Tier 2 Certification A Quick Start Guide to Fiber-to-the-Antenna (FTTA) Installation and Maintenance Testing Vol. 2 Tier 2 Certification Notice Copyright Every effort was made to ensure that the information in this document

More information

Ensuring the Health of Tomorrow s Fiber LANs Part II OTDR Trace Analysis Become an Expert Troubleshooter with Advanced OTDR Trace Analysis

Ensuring the Health of Tomorrow s Fiber LANs Part II OTDR Trace Analysis Become an Expert Troubleshooter with Advanced OTDR Trace Analysis Ensuring the Health of Tomorrow s Fiber LANs Part II OTDR Trace Analysis Become an Expert Troubleshooter with Advanced OTDR Trace Analysis Experience designing cable and network testers has enabled a breakthrough

More information

Architectural and Engineering Specification for a. Flash / Flare

Architectural and Engineering Specification for a. Flash / Flare Architectural and Engineering Specification for a Flash / Flare June 27, 2014 Page 1 of 12 T1DA0115-001 Rev D This document is intended to provide performance specifications and operational requirements

More information

TRM 2.0 Test Results Manager All-In-One Comprehensive Analysis and Reporting Software

TRM 2.0 Test Results Manager All-In-One Comprehensive Analysis and Reporting Software TRM 2.0 Basic Software Features Generate professional acceptance reports including: OTDR traces Certification loss results/opm loss results Connector end-face images from FOCIS and DFS1 Create certification

More information

TFS-FS1 Optical Leakage Detector. Operation Manual

TFS-FS1 Optical Leakage Detector. Operation Manual TFS-FS1 Optical Leakage Detector Operation Manual Trilithic Company Profile Trilithic is a privately held manufacturer founded in 1986 as an engineering and assembly company that built and designed customer-directed

More information

OPX-BOX. Platform Highlights. Software Support. Key Features

OPX-BOX. Platform Highlights. Software Support. Key Features Ultra Compact, Highly Versatile OTDR with Bluetooth Wireless and USB Control The VeEX is an ultra-compact, OTDR designed to operate remotely using Fiberizer software. The unit can be controlled via USB

More information

palmotdr Series Handheld OTDR

palmotdr Series Handheld OTDR palmotdr Series Handheld OTDR Most Compact High-Performance OTDR Comprehensive fiber applications, ideal for LAN/WAN/FTTx certification & trouble-shooting: SM: 1310/1490/1550, 1625/1650nm (with filter),

More information

FlexScan OTDR With SmartAuto and LinkMap

FlexScan OTDR With SmartAuto and LinkMap FlexScan OTDR With SmartAuto and LinkMap Quick Reference Guide Test & Inspection Controls, Display, Interfaces 1 2 4 8 1. Power button 2. Power jack (5 VDC) 3. Charge/AC indicator 4. USB ports 5. OTDR/source

More information

Quality Assurance and Quality Control of Optical Fibres for CERN

Quality Assurance and Quality Control of Optical Fibres for CERN EN Seminar - Quality Assurance and Quality Control of Optical Fibres for CERN Elisa GUILLERMAIN and Johannes TROLLER on behalf of the Cabling and Optical Fibre Section (EN-EL-CF) Seminar Outline 2 Johannes

More information

This is to certify that the optical output of the: SENSORNET LR-DTS Temperature Sensing System: (Variants Mark 1, Mark 2a and Mark 2b)

This is to certify that the optical output of the: SENSORNET LR-DTS Temperature Sensing System: (Variants Mark 1, Mark 2a and Mark 2b) Optical Services Ltd. This is to certify that the optical output of the: SENSORNET LR-DTS Temperature Sensing System: (Variants Mark 1, Mark 2a and Mark 2b) Meets the requirements stated in IEC 60825-1:2001

More information

ITU-T L.404. Field mountable single-mode optical fibre connectors

ITU-T L.404. Field mountable single-mode optical fibre connectors I n t e r n a t i o n a l T e l e c o m m u n i c a t i o n U n i o n ITU-T L.404 TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU (08/2017) SERIES L: ENVIRONMENT AND ICTS, CLIMATE CHANGE, E-WASTE, ENERGY

More information

Yokogawa Meters & Instruments Releases AQ1200E, AQ1205A, AQ1205E, and AQ1205F OTDR Multi Field Testers

Yokogawa Meters & Instruments Releases AQ1200E, AQ1205A, AQ1205E, and AQ1205F OTDR Multi Field Testers PRESS RELEASE Corporate Marketing Telephone: 770-254-0400 Fax: 678-423-2601 FOR IMMEDIATE RELEASE Date: June 20, 2012 Contact: info@us.yokogawa.com Contact Phone: 1-800-888-6400 Release #: 1037 Yokogawa

More information

M700-Series OTDRs. or (800) , (603)

M700-Series OTDRs.  or (800) , (603) Features M700 Compact QUAD OTDR M700 OTDR with DFS1 Digital FiberScope Integrated OPM and VFL (650 nm) Inspection capable with the DFS1 FiberScope Full Auto, Expert, and Real-Time OTDR test modes Automatic

More information

Hands-On Fiber Optics ISP/OSP - Advanced Combo- Tech

Hands-On Fiber Optics ISP/OSP - Advanced Combo- Tech Hands-On Fiber Optics ISP/OSP - Advanced Combo- Tech Course Description This Hands-On 3-day course has been customized to provide technicians with a practical understanding of fiber optic theory and fiber

More information

Apr06 Rev A

Apr06 Rev A Qualification Test Report LC, Multimode, One-Piece Housing, Fiber Optic Connector 501-628 03Apr06 Rev A 1. INTRODUCTION 1.1. Purpose 1.2. Scope Testing was performed on Tyco Electronics LC multimode, one-piece

More information

Qualification Test Report LC Duplex Adapter For LC Cutouts

Qualification Test Report LC Duplex Adapter For LC Cutouts Qualification Test Report LC Duplex Adapter For LC Cutouts 501-683 09Mar09 Rev B 1. INTRODUCTION 1.1. Purpose Testing was performed on Tyco Electronics LC Duplex Adapters for LC Cutouts, to determine their

More information

ASSMANN ELECTRONIC GmbH ASSMANN SYSTEM GUARANTEE. DIGITUS Professional Fiber Optic Cabling System. Appendix B - Provisions for acceptance

ASSMANN ELECTRONIC GmbH ASSMANN SYSTEM GUARANTEE. DIGITUS Professional Fiber Optic Cabling System. Appendix B - Provisions for acceptance ASSMANN ELECTRONIC GmbH ASSMANN SYSTEM GUARANTEE DIGITUS Professional Fiber Optic Cabling System Appendix B - Provisions for acceptance Page 1 Table of contents 1. Acceptance test of the installation link

More information

Certified Fibre Optic Specialist - Testing

Certified Fibre Optic Specialist - Testing Certified Fibre Optic Specialist - Testing COURSE DESCRIPTION: This training program is designed to introduce the student to the process of fibre optic network testing. It is intended for those looking

More information