DESIGNER AND SUPPLIER OF MARINE FIRE FIGHTING SYSTEMS

Size: px
Start display at page:

Download "DESIGNER AND SUPPLIER OF MARINE FIRE FIGHTING SYSTEMS"

Transcription

1 DESIGNER AND SUPPLIER OF MARINE FIRE FIGHTING SYSTEMS YOUR FIRE PROTECTOR

2

3 3 /aksisfire

4 QUALITY MANAGEMENT SYSTEM CERTIFICATES

5 WHO WE ARE 5 AKSIS formed by engineers who have extensive proven experience since 1994 in fixed based internal and external fire protection systems in the Marine and Offshore Industries, including Oil/Chemical Tankers, Cargo Vessels, Offshore Vessels, Fishing Vessels, Fi-Fi Tugs and Luxury Boats. AKSIS offers a very board range of marine related fire protection systems. Within these fields AKSIS s scope of work will cover from the design, equipment supply, field support and start up for new vessels or conversion according to specification and the rules. AKSIS has a multi-disciplined technical staff fully experienced in shipbuilding and fire protection system design and commissioning techniques. Full use is made of computer technology including AuroCAD programs. AKSIS can offer a complete range of fixed based fire protection systems and services for the marine industry. ENGINEERING CONSULTING SYSTEM DESIGN EQUIPMENT SPECIFICATION PROJECT MANAGEMENT STARTUP AFTER SALES SUPPORT MAINTENANCE SPARE PARTS

6 6 MX 1230 NOVEC (CLEAN GAS) At sea, safety requirements for ships are of the utmost importance. This also applies to fire protection measures. After all, in the event of fire, rapid escape is usually impossible and the prompt arrival of help from outside cannot be expected. In light of the various types of fire risks which exist on board ships, specific solutions are necessary for the space or object to be protected in order to ensure optimal fire protection on board. Areas that deserve special attention include rooms with electrical and electronic devices, such as control rooms, control cabinets and smaller machine rooms on ships. In such risk areas, extinguishing systems which put out fires quickly yet carefully are essential, in order to ensure that sensitive equipment is not damaged by residues left by the extinguishing agent. With the MX 1230 Marine and MX 200 Marine clean agent fire suppression system, Aksis has developed solutions which meet the demanding requirements on board a ship. For instance, the fire suppression systems can even be dimensioned with 50-bar system pressure. The systems are distinguished through the presence of the authorised and tested chemical suppressors NovecTM 1230 and HFC-227ea: neither fire suppressor is corrosive nor electrically conductive, nor causes any damage to sensitive parts through short circuits or residues. The MX 1230 Marine and MX 200 Marine dean agent fire suppression systems are available for tugboats, coast and inland navigation vessels and small yachts, in addition to drilling rigs The size of the room to be protected is a key focus for both systems. As a result, they offer optimal fire protection in smaller rooms, and are fully certified with all major marine sector approvals. /aksisfire

7 SPRINKLER SYSTEMS 7 Sprinkler systems are self-acting fire extinguishing systems having an uncomplicated as well a safe functioning principle. A network of piping and sprinkler heads are installed throughout the areas of the building requiring protection and is constantly under pressure. Under normal conditions the sprinkler head is closed off by a liquid-filled bulb. If due to the effects of a fire, the ambient temperature in the immediate vicinity rises by approximately 30 c above the maximum temperature expected under normal conditions, the glass bulb bursts. Then pressurized extinguishing water flows through the piping into the sprinkler head and the resulting water jet hits the spray plate which diverts the spray to the areas to be covered. At the same time the water flow in the piping network trips the alarm systems. When the fire is extinguished, replace the activated sprinkler that was activated and the system is ready for operation again.

8 8 MINIFOG MARINE HIGH PRESSURE WATER MIST SYSTEM PROTECTION The special conditions at sea mean that safety is an incredibly important issue for ships. The aim is to prevent any danger to make sure everything runs smoothly on board. And the key safety issue for passenger ships is of course the people on board. Ships are subject to a whole range of fire risks, which means fire protection on board has to be all the more effective. After all, in the event of a fire, it is not as easy to escape when at sea, and prompt fire-fighting assistance from outside cannot be counted on. Minimax has developed the Minifog marine XP water mist extinguishing system specially for maritime risks. It takes high-pressure technology to new dimensions. Many years of experience in water mist extinguishing technology and the marine sector have gone into the research, and the Minifog marine XP is the result. It complies with all relevant directives and, above all, it is extremely easy to use. Minifog marine XP offers the optimum allaround protection for seagoing and inland navigation vessels. The fire protection system can protect passenger, public and storage areas, as well as engine rooms. In short, it s an entirely new level of operational safety. The Minifog marine XP features a sophisticated design which has been thought through right down to the last detail from installation to protection against clogging or breakdown. The efficient Minifog marine XP water mist extinguishing system can be used in all areas of the ship: Accommodation, public space and store areas Engine rooms Local application system Minifog marine XP advantages: Uses 90% less extinguishing water than classic sprinkler systems. Engine rooms of up to 8,235 m³ volume. Conduit diameters from 10 to 42 mm save valuable space. No separate fi re protection system needed to protect the engine rooms. Just one sprinkler in a cabin can cover up to 32 m². Sprinklers can be spaced up to 6 m apart in the corridors. Protects the entire engine rooms, including objects and the bilge, with just one nozzle type. Stainless steel sprinklers and nozzles. Sprinkler and nozzle outlet ports 1 mm in diameter or more. No risk at clogging. Engine rooms (incl. bilge) can be protected without foaming agent. /aksisfire

9 CO2 SYSTEM 9 Carbon Dioxide has been used as an extinguishant in fixed installations since the beginning of the twentieth century, Carbon Dioxide is a colourless, odourless, dry, inert gas and is one of the most Wellknown of all fire extinguishants. The standard size cylinders used for the system is 67.5 L steel cylinders filled with 5 Kg of Carbon Dioxide. Cylinders can be delivered in accordance with the requirements of the various national authorities, including required stamping and certificates

10 10 SAMPLE EXTRACTION SMOKE DETECTION SYSTEM II-2, Regulation 13-1 The smoke detection system is suitable for controlling up to cargo holds. It uses the existing CO2 fire extinguishing pipe work through which air is continually sucked from the cargo hold. In the smoke detection system itself the air which has been taken from the cargo hold is examined for smoke and blown out of the vessel by fans. The smoke detection system SDS-48 is explosion protected. For remote indication of fire alarms and faults a repeater panel must be installed in the wheelhouse. It will be connected to the smoke detection panel only by a 4-wire cable. /aksisfire

11 FOAM EXTINGUISHING SYSTEM 11 With a versatile foaming agent range, Aksis offers safe and flexible application. Perfectly aligned components are supplied in line with the individual needs of clients and according to respective fire protection requirements. FOAM SPRINKLERS AND NOZZLES Aksis supplies sprinklers for the production of low expansion foam, Aksis also specialises in stainless steel nozzles for low expansion foam extinguishing systems.

12 12 HIGH EXPANSION FOAM GENERATOR Generators produce high expansion foam, which is used to protect storage areas. MINIFOG WATERMIST SYSTEM (Local Application System) MINIFOG WATERMIST SYSTEM (Local Application System) Ships require particularly high standards of safety on account of the particular conditions at sea, This applies especially to fire protection, and in particular in and around the engine room, which is home to fuel lines and other supply lines such as those that feed the main engines, auxiliary diesel engines, boiler burners,fuel separators and pumps - all these are typical areas of risk which must be considered when choosing an extinguishing system. The International Maritime Organization (IMO) therefore recommends a per manent, quick activation fire fighting system to protect equipment on board in addition to the total flooding fire suppression system. /aksisfire

13 FIRE DETECTION AND ALARM SYSTEM 13 Fire detection systems are essential components of a responsible safety management concept each object and each area of use holds special risks and requirements. Aksis provides for the optimum detection of fires and the perfect. Safe and fast fire detection is an essential component of a reliable fire protection concept. The earlier a fire is detected, the smaller the hazards and damages caused by the fire. Here, customized planning is of special importance~ The cooperation of fire protection control panel, detectors and alarms facilitates a fast reaction in case of fire - ideally, by automatic activation of an extinguishing system. In this way you will have the situation under control immediately. WATER SPRAY SYSTEM If conditions are such that extremely rapid spreading of a fire can be expected, then Aksis water-spray extinguishing systems can provide maximum safety. Water-spray extinguishing systems operate with open extinguisher nozzles which, in the event of fire, distribute the extinguishing water over the entire protected area, the quantity of extinguishant needed being minimal. Spray extinguishing increases the surface area of the extinguishing water, entrains the heat of in addition to this cooling effect there is a smothering effect because the steam produced impedes the oxygen supply to the base of the fire. Water-spray extinguishing systems are designed for space or equipment protection. In the case of space protection the extinguishing water is distributed evenly across the whole area of the fire hazard. The extinguishing nozzles are therefore arranged evenly spaced at ceiling level, In the case of equipment protection systems, defined objects particularly subject to fire hazard are provided with water spray for protection or for preventive cooling. The extinguishing nozzles are therefore arranged to be specifically aimed at the object. For tall objects they may also be installed at several levels.

14 14 DEEP FAT FRYER SYSTEM The KS compact extinguishing system has been speci cally designed for use in catering kitchens. The re detection elements repond the moment the rst small ame occurs, and the re is promptly extinguished before serious damage occurs. DRY POWDER SYSTEM The extinguishing powders used in powder extinguishing systems are highly efficient, quick-acting extinguishants. The sudden extinguishing effect of the powder cloud is caused by the suffocation effect and the anticatalytic effect, a chemical intervention into the combustion process. Extinguishing powders mainly consist of non-poisonous inorganic salts mixed with waterproofing and pouring agents. They are used for fires with solid, liquid or gaseous substances and for metal fires, thus, they are used for fire classification A, B, C and D. /aksisfire

15 GAS DETECTION SYSTEM 15 SIL-1 Certified MX 43 is a Flexible, High Quality, Easy to Use Gas Detection System Fully scalable, and designed to functional safety performance level 1 standards, the MX 43 is an analog and digital controller that continuously measures and controls gases in the atmosphere. The MX 43 gas detector manages both digital lines and analog channels, and covers all needs for a wide variety of gas monitoring applications. The MX 43 digital technology allows up to 32 detectors to be distributed on 8 lines for increased cost savings. Toxic and Combustible Gas Detector Designed for the detection of explosive gases, toxic gases or oxygen, this combustible gas detector comes with a Wheatstone bridge output (OLC 100) or 4-20mA output (OLCT 100). Whatever your application 3M offers a solution: catalytic, electrochemical, semiconductor, or poison control version. ATEX approved, these detectors are available in explosion safe or intrinsically safe versions. In addition to this range the OLC/OLCT 100 offers an infrared sensor, which allows it to be used in more severe environmental conditions, where the presence of poisons could harm the use of a catalytic sensor. With a 3-year warranty on the sensor and electronics, the OLCT 100 XP-IR will provide reliability and extended lifetime. With this new line of detectors, 3M broadens its product range with products that combine reliability, durability and ease of use. SIL 2 certified according to EN 50402, the 100 series is very safe. As an example the Probability of Failure on Demand (PFD) of combustible versions is 1 out of 418 for the catalytic version and 1 out of 2857 for the infrared version. GD10P Gas Detector The GD10P has been designed with features that provide an effective response to the detection of gas hazards in a wide range of industrial environments from boiler plant rooms to offshore petrochemical installations. These infrared gas detectors differ from all other models, because they utilize silicon based solid-state infrared sources. The complete optomechanical design and construction is so stable that an ultra fast speed of response can be achieved while providing unparalleled service life and detector stability, thus saving on maintenance and service costs. We offer the longest combined detector and IR source warranty on the market. For retrofit applications, a bridge interface is available allowing the detector to be connected directly to catalytic systems, using the existing cabling and control modules. Supplied with worldwide performance and hazardous area approvals. Suitable for use in SIL 2 & SIL 3 systems. An industry standard HART interface is used for configuration of the optical fast response time and special fault levels as well as access to extended maintenance data.

16 16 OneU FIRE PROTECTION SYSTEMS Functioning IT systems should not be taken for granted. Yet for companies that have to ensure a high level of data availability, with ever more powerful systems, this reliability is often a matter of survival. High thermal loads are generated especially in high-tech 19 racks with a compact design, which may eventually lead, in the worst case, to the outbreak of a fire. OneU fire protection systems offer optimal protection in these circumstances. These devices are truly innovative, with minimal space requirements for a full range of equipment. /aksisfire

17 EXTERNAL FIRE FIGHTING SYSTEMS (Fi-Fi I,II,III) 17 Aksis supplies external fire fighting systems from the world s leading supplier Fire Fighting Systems AS (FFS) NON - CLASSED FIFI VESSELS (Fi-Fi O) Any type of vessel with an external FiFi system but without any formal classification will be covered under this heading. Normally capacities between 37 m3 / h and u p to FiFi I ( 2400 m3 / h) are used. Fire water for the monitors may be supplied by one ore more fire pumps, driven by dedicated diesel engines, PTO gearboxes or electrically driven pumps, The monitors can be either remote controlled (recommended) or manual. Fi-Fi l The class notation FiFi I means that the vessel is to be equipped with minimum 2 fire monitors, able to throw water to a minimum distance of 120 meters from the vessel and to a height of minimum 45 meters. The monitors are to be remote controlled from the wheelhouse. Since the fire pumps and related equipment are located in the engine room these are also normally remote controlled, FiFi I Systems are normally installed on Escort tugs, Fire fighting vessels etc. Fi-Fi ll The class notation FiFi II means that the vessel is to be equipped with minimum 2 fire monitors, (DNV rules) able to throw water to a minimum distance of 180 meters from the vessel and to a height of minimum 110 meters, or if other classification for the vessel (i.e. LRS, ABS, R.I.N.A, BV, GL etc), the vessel is to be equipped with 3 or 4 fire monitors, able to throw water to a minimum distance of 150 meters from the vessel and to a height of minimum 7Ometers, Whatever configuration is chosen for the FIFI II vessel the total water capacity shall be not less than 7200 m3/h, The monitors are to be remote controlled from the wheelhouse, Since the fire pumps and related equipment are located in the engine room these are also normally remote controlled. FiFi II Systems are normally installed on offshore vessels like Anchor-handling tug / supply vessels, or other specialised vessels. Fi-Fi III The class notation FiFi III means that the vessel is to be equipped with minimum 3 fire monitors, (DNV rules) able to throw water to a minimum distance of 180 meters from the vessel and to a height of minimum 110 meters, or if other classification for the vessel (i.e. LRS, ABS, R.I.N.A, BV, GL etc), the vessel is to be equipped with 4 fire monitors, able to throw water to a minimum distance of 150 meters from the vessel and to a height of minimum 7Ometers, Whatever configuration is chosen for the FIFI II vessel the total water capacity shall be not less than 9600 m3/h, The monitors are to be remote controlled from the wheelhouse, Since the fire pumps and related equipment are located in the engine room these are also normaliv remote controlled. FiFi III Systems are not so common, but are normally installed on larger offshore vessels, or other specialised vessels.

18 CONTACT HEAD OFFICE Deri O.S.B. Kazlıçeşme Cad. No: 5 Çarşı Kompleksi Kat : 1 No : Tuzla / IST. Phone: Fax: aksisfire@aksisfire.com.tr

19

20 /aksisfire

Fire protection solutions for ships and offshore facilities

Fire protection solutions for ships and offshore facilities Experts in fire protection Fire protection solutions for ships and offshore facilities BRANCH SOLUTION MARINE OVERVIEW Top level of safety on board Minimax has been one of the leading fire protection brands

More information

Fire protection solutions for ships and offshore facilities BRANCH SOLUTION

Fire protection solutions for ships and offshore facilities BRANCH SOLUTION Fire protection solutions for ships and offshore facilities BRANCH SOLUTION SAFETYCompetent Ships and offshore facilities such as oil platforms require an above-average level of safety due to the special

More information

FIRE SUPPRESSION SOLUTIONS

FIRE SUPPRESSION SOLUTIONS FIRE SUPPRESSION SOLUTIONS MARITIME FIRE SUPPRESSION In the maritime world space is a luxury. That is why it is important getting maximum effect from your fire suppression with a space and power-efficient

More information

Branch Solution Wood based panel plants. Fire protection solutions for wood based panel plants

Branch Solution Wood based panel plants. Fire protection solutions for wood based panel plants Branch Solution Wood based panel plants Fire protection solutions for wood based panel plants afety throughout the production process R The versatility of wood as a raw material and the fact that it is

More information

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Aluminium or Stainless Steel version

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Aluminium or Stainless Steel version Fixed Gas Detector Detection of explosive gases, toxic gases or oxygen Infrared XP version SIL 2 high reliability IP 66 Aluminium or Stainless Steel version Certifications Pending The Fixed Gas Detection

More information

FIRE PROTECTION TECHNOLOGY Solutions never thought of before

FIRE PROTECTION TECHNOLOGY Solutions never thought of before FIRE PROTECTION TECHNOLOGY Solutions never thought of before More than 25 years in engineering, manufacturing and maintenance of certified fire fighting systems and products. TEMA SISTEMI There was a time

More information

Element C3.4 Fire Fighting Equipment

Element C3.4 Fire Fighting Equipment .4 Fire Fighting Equipment Classification of Fires Class A Solids. Wood, paper, plastics Class B Liquids Petrol oil, paint Class C Gases LPG, natural gas Classification of Fires Class D Metals Zinc, sodium,

More information

MistMax Pro; A WaterMist fire skid designed for your UTV or smaller fire fighting vehicle.

MistMax Pro; A WaterMist fire skid designed for your UTV or smaller fire fighting vehicle. MistMax Pro; A WaterMist fire skid designed for your UTV or smaller fire fighting vehicle. 2 MistMax Low pressure WaterMist fire suppression skid Our modular fire skid is customised to suit your specific

More information

OLC(T) 100 FIXED GAS DETECTOR

OLC(T) 100 FIXED GAS DETECTOR Fixed Gas Detector OLC(T) FIXED GAS DETECTOR Detection of explosive gases, toxic gases or oxygen Infrared XP version SIL 2 high reliability IP 66 Aluminium or Stainless Steel version CERTIFICATIONS The

More information

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Certifications. The Fixed Gas Detection People

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Certifications. The Fixed Gas Detection People Fixed Gas Detector Detection of explosive gases, toxic gases or oxygen Infrared XP version SIL 2 high reliability IP 66 Certifications The Fixed Gas Detection People The OLC/OLCT CT range of fixed ddetectors

More information

3years. Detection of explosive gases, toxic gases and oxygen. Infrared XP IR version. SIL 2 high reliability IP 66.

3years. Detection of explosive gases, toxic gases and oxygen. Infrared XP IR version. SIL 2 high reliability IP 66. Fixed Gas Monitoring Solutions Detection of explosive gases, toxic gases and oxygen Infrared XP IR version SIL 2 high reliability IP 66 E n o r t c e l i c 3years W a r r a t n y Certifications: The Fixed

More information

Fixed Fire Extinguishing Equipment and Systems

Fixed Fire Extinguishing Equipment and Systems Fixed Fire Extinguishing Equipment and Systems Sea Term 2016 Massachusetts Maritime Academy January 2016 DESIGN AND INSTALLATION OF FTXED SYSTEMS Fire extinguishing systems are designed and installed

More information

Global Marine Solutions and Services From Ship to Shore Single Source Providers for Fire, Security, Life Safety

Global Marine Solutions and Services From Ship to Shore Single Source Providers for Fire, Security, Life Safety Safer. Smarter. Tyco. TM Global Marine Solutions and Services From Ship to Shore Single Source Providers for Fire, Security, Life Safety Specialists in Fire, Security & Life Safety Over 100 years experience

More information

Introduction. Our team

Introduction. Our team Introduction Staadco Marine International Pte Ltd is a subsidiary of Staadco Agency Pte Ltd which established more than 30 years in the freight forwarding industry. Staadco Marine International Pte Ltd

More information

SHIPBUILDING FIRE PROTECTION WATER MIST SYSTEM SAID. DONE!

SHIPBUILDING FIRE PROTECTION WATER MIST SYSTEM SAID. DONE! SHIPBUILDING FIRE PROTECTION WATER MIST SYSTEM The KJ FireOff Water Mist System The special conditions at sea mean that safety is an incredibly important issue for ships. Ships are subject to a whole range

More information

GAS EXTINGUISHING SYSTEM INERT GAS. Argotec with carbon dioxide. Safe for certain.

GAS EXTINGUISHING SYSTEM INERT GAS. Argotec with carbon dioxide. Safe for certain. GAS EXTINGUISHING SYSTEM INERT GAS Argotec with carbon dioxide Safe for certain. PPLICATIO VERSATILE Reliable extinguishing Fighting fires quickly and effectively is the strong point of Argotec extinguishing

More information

Inert Gas Fire Extinguishing System

Inert Gas Fire Extinguishing System s & Equipment Manufact s & Equipment Manufact s & Equipment Manufact s & Equipment Manufact s & Equipment Manufact s & Equipment Manufact s & Equipment Manufact s & Equipment Manufact s & Equipment Manufact

More information

3M Oldham OLCT 100. Description. Fixed Gas Detector

3M Oldham OLCT 100. Description. Fixed Gas Detector Fixed Gas Detector Description The OLC/OLCT range of fixed detectors has been designed for detection of combustible gases, toxic gases or oxygen. Available in explosion-proof or intrinsically safe versions,

More information

OLCT 100 DETECTION DE GAZ FIXE. Certifications. Better detection. Better protection. Detection of Combustible, Toxic or Oxygen gases

OLCT 100 DETECTION DE GAZ FIXE. Certifications. Better detection. Better protection. Detection of Combustible, Toxic or Oxygen gases DETECTION DE GAZ FIXE OLCT Detection of Combustible, Toxic or Oxygen gases Infrared XP version SIL 2 high reliability IP 66 Aluminium or Stainless Steel version Certifications Better detection. Better

More information

Nessie High Pressure Water Mist Components for Fire Fighting

Nessie High Pressure Water Mist Components for Fire Fighting Nessie High Pressure Water Mist Components for Fire Fighting Generally Quick overview of the Nessie product portfolio used in Fire Fighting applications within Marine, Mobile and Spot systems typically

More information

FT NAVVISION AMCS TYPE-APPROVED, USER-CENTERED YACHT AUTOMATION

FT NAVVISION AMCS TYPE-APPROVED, USER-CENTERED YACHT AUTOMATION FT NAVVISION AMCS TYPE-APPROVED, USER-CENTERED YACHT AUTOMATION Yachting has never been so easy and comfortable. FT NavVision AMCS. As versatile as you need it. The FT NavVision Alarm, Monitoring & Control

More information

Carbon Dioxide Extinguishing Systems Fighting fire with CO2

Carbon Dioxide Extinguishing Systems Fighting fire with CO2 Carbon Dioxide Extinguishing Systems Fighting fire with CO2 TECHNOLOGIES GAS-BASED SUPPRESSION SYSTEMS Highly effective for many applications Quick and effective fire fighting is the strong point of carbon

More information

Minifog PressProtect Fire protection solutions for industrial presses BRANCH SOLUTION

Minifog PressProtect Fire protection solutions for industrial presses BRANCH SOLUTION Minifog PressProtect ire protection solutions for industrial presses BRANCH SOLUTION RISKS detect During the production of OSB, PB, MD and HD boards with continuous or multi-opening presses, combustible

More information

High pressure water mist sprinkler system for fighting fires

High pressure water mist sprinkler system for fighting fires High pressure water mist sprinkler system for fighting fires Topics Introduction to ULTRA FOG. High Pressure Water Mist. Ultra Fog Engineering & Products, and Testing. Performance, perceptions and advantages.

More information

Emergency shutdown systems. Procedures for bypassing ESD s

Emergency shutdown systems. Procedures for bypassing ESD s HYDROCARBON PROCESS SAFETY 2 - ELEMENT 3 - UNIT IOG1 Emergency shutdown systems Emergency shutdown systems (ESD s) are intended to minimise the consequences of emergency situations, for example, the uncontrolled

More information

DRY BULK HANDLING SYSTEM

DRY BULK HANDLING SYSTEM DRY BULK HANDLING SYSTEM Parson Marine Equipment is established in Singapore since July 2005. Our team of engineers have more than 25 years of experiences in providing customised integrated dry and wet

More information

GAS EXTINGUISHING SYSTEMS INERT GAS. Argotec with argon or nitrogen

GAS EXTINGUISHING SYSTEMS INERT GAS. Argotec with argon or nitrogen GAS EXTINGUISHING SYSTEMS INERT GAS Argotec with argon or nitrogen NATUR AL without any damage to the atmosphere The extinguishing gases Argon and nitrogen extinguish a fire by oxygen displacement. When

More information

w-fog RG-SYSTEMS W-FOG WATER MIST CO-OPERATI

w-fog RG-SYSTEMS W-FOG WATER MIST CO-OPERATI W w-fog RG-SYSTEMS W-FOG WATER MIST CO-OPERATI WHY USE WATER MIST? Nowadays and increasingly, water is a scarce commodity. RG W-FOG s innovative design means that the amount of water used for fire protection

More information

THE REPUBLIC OF LIBERIA LIBERIA MARITIME AUTHORITY

THE REPUBLIC OF LIBERIA LIBERIA MARITIME AUTHORITY THE REPUBLIC OF LIBERIA LIBERIA MARITIME AUTHORITY 8619 Westwood Center Drive Suite 300 Vienna, Virginia 22182, USA Tel: +1 703 790 3434 Fax: +1 703 790 5655 Email: safety@liscr.com Web: www.liscr.com

More information

Special solution KS marine. Kitchen protection system KS marine Fire prevention for galleys

Special solution KS marine. Kitchen protection system KS marine Fire prevention for galleys Special solution KS 2000-8 marine Kitchen protection system KS 2000-8 marine Fire prevention for galleys RiskDeep fat fryer fire Safety requirements for passengers and crew are especially high at sea.

More information

Fire protection for buildings

Fire protection for buildings Fire protection for buildings HI-FOG high-pressure water mist Ghelamco Group Protecting people, property and business continuity A fire in a building can lead to serious consequences. Even a harmless fire

More information

POSITION PAPER ON WATER MIST FOR FIRE FIGHTING APPLICATIONS

POSITION PAPER ON WATER MIST FOR FIRE FIGHTING APPLICATIONS FIRE EXTINGUISHING INSTALLATIONS SECTION POSITION PAPER ON WATER MIST FOR FIRE FIGHTING APPLICATIONS Version 1 29-09-04 0 Eurofeu position paper on water mist for fire fighting applications 1 Scope The

More information

GAS EXTINGUISHING SYSTEMS INERT GAS. Argon Extinguishing Systems. Fire Protection Systems

GAS EXTINGUISHING SYSTEMS INERT GAS. Argon Extinguishing Systems. Fire Protection Systems GAS EXTINGUISHING SYSTEMS Argon Extinguishing Systems Fire Protection Systems EFFECTIVE NATURAL no damage to the atmosphere technology for complex applications EXAMPLE GAS EXTINGUISHING SYSTEMS solution

More information

AUTOMATIC FIRE SUPPRESSION SYSTEMS

AUTOMATIC FIRE SUPPRESSION SYSTEMS AUTOMATIC FIRE SUPPRESSION SYSTEMS Effective automatic fire suppression systems are essential for the fire protection of mechanical equipment and special technologies. CONTENTS RSBP FIRE PROTECTION OF

More information

Oxeo extinguishing systems

Oxeo extinguishing systems Experts in fire protection Oxeo extinguishing systems TECHNOLOGIES GAS EXTINGUISHING SYSTEMS Residue-free fire extinguishing Oxeo extinguishing systems from Minimax use nitrogen and argon to fight fire.

More information

SIL 2. Ultima X Series Gas Monitors CERTIFIED

SIL 2. Ultima X Series Gas Monitors CERTIFIED Ultima X Series Gas Monitors 5 Now with SIL 2 CERTIFIED Products Versatile fixed instruments provide continuous monitoring of many hazardous gases using catalytic, electrochemical, and infrared gas detection

More information

WATER MIST CONVENTION AND EXHIBITION

WATER MIST CONVENTION AND EXHIBITION INTERNATIONAL WATER MIST ASSOCIATION IWMA SEMINARS S ON WATER MIST TECHNOLOGY DUBAI INTERNATIONAL CONVENTION AND EXHIBITION CENTRE Water mist fire protection: The most innovative fire fighting technology

More information

Technologies Gas extinguishing systems. MX 1230 Fire Extinguishing Systems Fighting Fire using 3M Novec 1230

Technologies Gas extinguishing systems. MX 1230 Fire Extinguishing Systems Fighting Fire using 3M Novec 1230 Technologies Gas extinguishing systems MX 1230 Fire Extinguishing Systems Fighting Fire using 3M Novec 1230 ire protection Efficient and compact MX 1230 fire extinguishing systems fight fires using Novec

More information

FIRE SUPPRESSION SYSTEM

FIRE SUPPRESSION SYSTEM FIRE SUPPRESSION SYSTEM An effective fire suppression systems work fundamentally in three ways; The corner stone has to be an efficient means of early warning/detection. Followed by either an Oxygen reduction

More information

DASPOS A/S Gammel Klausdalsbrovej Herlev Denmark Tel.: website: DASPOS USA, Inc NE 116th Street, PMB

DASPOS A/S Gammel Klausdalsbrovej Herlev Denmark Tel.: website:   DASPOS USA, Inc NE 116th Street, PMB LAS-10 - Leakage Alarm System Atmospheric oil mist and hydrocarbon detection Early warning system Your challenges Each year, there are several hundred fires recorded aboard merchant ships; 63% occur in

More information

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors Ultima X Series Gas Monitors Versatile fixed instruments provide continuous monitoring of many hazardous gases using catalytic, electrochemical, and infrared gas detection methods. HART Protocol is now

More information

Technologies Gas extinguishing systems. MX 200 Fire Extinguishing Systems Fighting Fire using HFC-227ea

Technologies Gas extinguishing systems. MX 200 Fire Extinguishing Systems Fighting Fire using HFC-227ea Technologies Gas extinguishing systems MX 200 Fire Extinguishing Systems Fighting Fire using HFC-227ea ire protection Efficient and compact MX 200 fire extinguishing systems fight fires using HFC-227ea.

More information

FAIRBANKS NIJHUIS FIRE PROTECTION. FIRE PUMP SETS & PUMP PACKAGES

FAIRBANKS NIJHUIS FIRE PROTECTION.  FIRE PUMP SETS & PUMP PACKAGES FAIRBANKS NIJHUIS FIRE PROTECTION FIRE PUMP SETS & PUMP PACKAGES www.fairbanksnijhuis.com MORE THAN JUST A PUMP Pump Room Engineering Pentair s Fairbanks Nijhuis Fire Protection offers a complete pump

More information

SAFETY MANUAL. FL4000H and FL4000 Multi-Spectral Infrared Flame Detectors

SAFETY MANUAL. FL4000H and FL4000 Multi-Spectral Infrared Flame Detectors SAFETY MANUAL FL4000H and FL4000 Multi-Spectral Infrared Flame Detectors The information and technical data disclosed in this document may be used and disseminated only for the purposes and to the extent

More information

TALK SAFETY WITH US MARINE SAFETY TECHNOLOGY. When Safety Matters

TALK SAFETY WITH US MARINE SAFETY TECHNOLOGY. When Safety Matters TALK SAFETY WITH US MARINE SAFETY TECHNOLOGY When Safety Matters Oil mist detection A MULTITUDE OF WAYS FORWARD. WHERE DO YOU WANT TO START? When you choose Consilium, you tap into an ocean of knowledge.

More information

Carbon Dioxide Fire Suppression Systems

Carbon Dioxide Fire Suppression Systems Carbon Dioxide Fire Suppression Systems The original "clean agent," carbon dioxide suppresses fire without leaving behind water, foam or dry chemical to damage sensitive equipment. And because there is

More information

FAIRBANKS NIJHUIS FIRE PROTECTION. FIRE PUMP SETS & PUMP PACKAGES

FAIRBANKS NIJHUIS FIRE PROTECTION.   FIRE PUMP SETS & PUMP PACKAGES FAIRBANKS NIJHUIS FIRE PROTECTION FIRE PUMP SETS & PUMP PACKAGES www.fairbanksnijhuis.com KNOW-HOW AND EXPERIENCE WATER A fire can be extinguished by pumping water to its source. Therefore the most critical

More information

Performance Based Fire Protection With Water Mist

Performance Based Fire Protection With Water Mist Performance Based Fire Protection With Water Mist the applications to industrial hazards, high rise buildings and other areas of interest PART 1 PART 2 PART 3 PART 4 PART 5 Marioff Corporation Why use

More information

Interaction of Water Extinguishing Systems and Smoke and Heat Exhaust Ventilation Systems (SHEVS)

Interaction of Water Extinguishing Systems and Smoke and Heat Exhaust Ventilation Systems (SHEVS) Fire Protection Leaflet Interaction of Water Extinguishing Systems and Smoke and Heat Exhaust Ventilation Systems (SHEVS) 0 General Regulations and recommendations missing from this leaflet do not entitle

More information

Fire Protection of Hotels. With SEM-SAFE High-Pressure Water Mist System

Fire Protection of Hotels. With SEM-SAFE High-Pressure Water Mist System Fire Protection of Hotels With SEM-SAFE High-Pressure Water Mist System Danfoss Semco A/S Total Solution Provider of Certified Fixed Fire Fighting Systems Aesthetic design and reliability with SEM-SAFE

More information

Combustible and Toxic Gas Detection Solutions. Performance and Safety Beyond Compliance

Combustible and Toxic Gas Detection Solutions. Performance and Safety Beyond Compliance Combustible and Toxic Gas Detection Solutions Performance and Safety Beyond Compliance Reliable Solutions from Det-Tronics, Your Partner in Safety Trusted Response with the Utmost Confidence Our proven

More information

FUNCTIONAL SAFETY IN FIRE PROTECTION SYSTEM E-BOOK

FUNCTIONAL SAFETY IN FIRE PROTECTION SYSTEM E-BOOK FUNCTIONAL SAFETY IN FIRE PROTECTION SYSTEM E-BOOK USEFUL TERMINOLOGY BASIC PROCESS CONTROL SYSTEM (BPCS) System which responds to input signals from the process, its associated equipment, other programmable

More information

F&G detection system for LNG plants

F&G detection system for LNG plants LNG PLANT F&G detection system for LNG plants The historical safety record for the LNG industry is strong. Engineering, installation and lifetime use takes into account the well known hazards of such an

More information

Exploration and extraction can be on land or on offshore platforms. Once extracted, ground transportation is done by means of oil or gas pipelines,

Exploration and extraction can be on land or on offshore platforms. Once extracted, ground transportation is done by means of oil or gas pipelines, Oil & Gas Exploration and extraction can be on land or on offshore platforms. Once extracted, ground transportation is done by means of oil or gas pipelines, FPSO vessels, tankers, LNG carriers, etc. The

More information

ADDITIONAL FIRE PROTECTION (F-AMC)

ADDITIONAL FIRE PROTECTION (F-AMC) RULES FOR CLASSIFICATION OF SHIPS NEWBUILDINGS SPECIAL EQUIPMENT AND SYSTEMS ADDITIONAL CLASS PART 6 CHAPTER 4 ADDITIONAL FIRE PROTECTION (F-AMC) JULY 2006 CONTENTS PAGE Sec. 1 General Requirements...

More information

THE FIXED AEROSOL EXTINGUISHING SYSTEM - FIRE JACK

THE FIXED AEROSOL EXTINGUISHING SYSTEM - FIRE JACK THE FIXED AEROSOL EXTINGUISHING SYSTEM - FIRE JACK 1. Introduction A) General information According to the European Community standard 2037/2000, it is prohibited in Europe, to employ extinguishing equipment

More information

MSC Guidelines for Watermist Fire Suppression Systems Procedure Number: E1-03 Revision Date: 02/16/2017

MSC Guidelines for Watermist Fire Suppression Systems Procedure Number: E1-03 Revision Date: 02/16/2017 Procedure Number: E1-03 Revision Date: 02/16/2017 References: S. T. Brady, CDR, Chief, Engineering Division a. National Fire Protection Association (NFPA) 750, 1996 Edition, Standard on Water Mist Fire

More information

Fully redundant and customizable alarm, monitoring & Control system

Fully redundant and customizable alarm, monitoring & Control system Imtech AMCS Fully redundant and customizable alarm, monitoring & Control system Photo Daniel Ramirez Reliable, stable, safe Imtech AMCS Imtech s new Alarm, Monitoring & Control System is the automation

More information

What is HI-FOG? The natural enemy of fire

What is HI-FOG? The natural enemy of fire What is HI-FOG? The natural enemy of fire Using water wisely in the fight against fire COOLS HI-FOG attacks the fire, cooling the fire itself and the space it is in. Water absorbs more heat (>2 MJ/kg)

More information

SAFETY MANUAL. Intelligent Sensors for H 2 S Gas Applications

SAFETY MANUAL. Intelligent Sensors for H 2 S Gas Applications SAFETY MANUAL Intelligent Sensors for H 2 S Gas Applications The information and technical data disclosed in this document may be used and disseminated only for the purposes and to the extent specifically

More information

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Dräger Polytron 8700 IR Detection of flammable gases and vapors Dräger Polytron 8700 IR Detection of flammable gases and vapors The Dräger Polytron 8700 IR is an advanced explosion proof transmitter for the detection of combustible gases in the lower explosion limit

More information

CERTIFICATE OF FIRE APPROVAL

CERTIFICATE OF FIRE APPROVAL CERTIFICATE OF FIRE APPROVAL This is to certify that The product detailed below will be accepted for compliance with the applicable Lloyd s Register Rules and Regulations and with the International Convention

More information

IR4000. Point Infrared Combustible Gas Detection System. The Reliable and Flexible Safety Solution That s Low Maintenance

IR4000. Point Infrared Combustible Gas Detection System. The Reliable and Flexible Safety Solution That s Low Maintenance IR4000 Point Infrared Combustible Gas Detection System The Reliable and Flexible Safety Solution That s Low Maintenance Multi-Point Gas Detection That s Fast Set-Up, Low Maintenance, Cost-Effective The

More information

Directories. B.1 Keyword Directory B.2 Tables B.3 Figures B.4 End Notes Fire Safety Guide / Siemens Switzerland Ltd

Directories. B.1 Keyword Directory B.2 Tables B.3 Figures B.4 End Notes Fire Safety Guide / Siemens Switzerland Ltd B Directories B.1 Keyword Directory...326 B.2 Tables...329 B.3 Figures...330 B.4 End Notes...332 325 B.1 Keyword Directory A addressing (collective) 93, 125 addressing (individual) 93 aerosol 69, 70, 95

More information

that sense s of ecurity

that sense s of ecurity thatsense of security thatsense of security THAT SENSE OF SECURITY OUR BUSINESS IS ABOUT protecting is important to you what 1 WHAT S IMPORTANT TO US arelationship our with clients WHAT S IMPORTANT TO

More information

OFFSHORE SUPPORT VESSELS 2014

OFFSHORE SUPPORT VESSELS 2014 RULES FOR BUILDING AND CLASSING OFFSHORE SUPPORT VESSELS 2014 NOTICE NO. 1 JULY 2014 The following Rule Changes were approved by the ABS Rules Committee on 28 May 2014 and become EFFECTIVE AS OF 1 JULY

More information

INFRARED PRODUCTS FOR MONITORING SMOKELESS FLARES, PILOTS, AND FLAME INTENSITY

INFRARED PRODUCTS FOR MONITORING SMOKELESS FLARES, PILOTS, AND FLAME INTENSITY INFRARED PRODUCTS FOR MONITORING SMOKELESS FLARES, PILOTS, AND FLAME INTENSITY >OLYL >H]LSLUN[O 4H[[LYZ SMOKELESS FLARE MONITOR Smokeless Flare Monitor (FM) Smokeless flares incinerate flammable hazardous

More information

Marine Fire safety for the ship industry

Marine Fire safety for the ship industry Marine Fire safety for the ship industry This is Firesafe Energy We offer a wide range of fire protection solutions for the marine sector. We have documented solutions for both newbuilding, maintenance

More information

Transmitters/Sensors. OLCT Series

Transmitters/Sensors. OLCT Series Transmitters/Sensors Gas Monitoring Solutions OLCT 20-40-50-60 Series SIL2 based on EN 50402 (OLCT 60 based on EN 50271) FLP approved Intrinsically Safe (IS) Precalibrated block module local or remote

More information

MB05. RESPOND TO EMERGENCIES BASIC KNOWLEDGE OF EMERGENCY PROCEDURES, INCLUDING EMERGENCY SHUTDOWN

MB05. RESPOND TO EMERGENCIES BASIC KNOWLEDGE OF EMERGENCY PROCEDURES, INCLUDING EMERGENCY SHUTDOWN MB05. RESPOND TO EMERGENCIES BASIC KNOWLEDGE OF EMERGENCY PROCEDURES, INCLUDING EMERGENCY SHUTDOWN Content of the lecture 1. DRILLS AND EMERGENCY EXERCISES (general requirements) 2. Emergency procedures

More information

APPLICATION BULLETIN COMBUSTION TURBINE FACILITIES. Overview

APPLICATION BULLETIN COMBUSTION TURBINE FACILITIES. Overview Overview Modern combustion (or gas) turbine packages typically include an axial compressor, a combustion section and a turbine. Both compressor and turbine sections consist of one or more sets of fixed

More information

Additional Fire Protection (F-AMC)

Additional Fire Protection (F-AMC) RULES FOR CLASSIFICATION OF Ships PART 6 CHAPTER 4 NEWBUILDINGS SPECIAL EQUIPMENT AND SYSTEMS ADDITIONAL CLASS Additional Fire Protection (F-AMC) JANUARY 2011 This chapter has been amended since the main

More information

SPECIAL HAZARDS THE MOST ADVANCED TECHNOLOGY FOR PROTECTING

SPECIAL HAZARDS THE MOST ADVANCED TECHNOLOGY FOR PROTECTING THE MOST ADVANCED TECHNOLOGY FOR PROTECTING SPECIAL HAZARDS There are numerous hazards where the use of dry chemical is the best option for firefighting, and where the use of portable fire extinguishers

More information

IMO. Resolution A.951(23) Adopted on 5 December 2003 (Agenda item 17) IMPROVED GUIDELINES FOR MARINE PORTABLE FIRE EXTINGUISHERS

IMO. Resolution A.951(23) Adopted on 5 December 2003 (Agenda item 17) IMPROVED GUIDELINES FOR MARINE PORTABLE FIRE EXTINGUISHERS INTERNATIONAL MARITIME ORGANIZATION E IMO ASSEMBLY 23rd session Agenda item 17 A 23/Res.951 25 February 2004 Original: ENGLISH Resolution A.951(23) Adopted on 5 December 2003 (Agenda item 17) IMPROVED

More information

Offshore. Optimum fire safety for oil & gas installations

Offshore. Optimum fire safety for oil & gas installations Offshore Optimum fire safety for oil & gas installations This is Firesafe Energy We offer a wide range of fire protection solutions for the offshore sector. We have documented solutions for both newbuilding

More information

RESOLUTION MSC.98(73) (adopted on 5 December 2000) ADOPTION OF THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS

RESOLUTION MSC.98(73) (adopted on 5 December 2000) ADOPTION OF THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS RESOLUTION MSC.98(73) THE MARITIME SAFETY COMMITTEE, RECALLING Article 28(b) of the Convention on the International Maritime Organization concerning the functions of the Committee, NOTING the revision

More information

CO 2 EXTINGUISHING SYSTEMS

CO 2 EXTINGUISHING SYSTEMS CO 2 EXTINGUISHING SYSTEMS CO 2 THE FIRE EXTINGUISHING CLASSIC: CLEAN, FAST AND RELIABLE TOTAL WALTHER, the acknowledged specialist in fire protection systems, has been manufacturing CO 2 extinguishing

More information

How can you minimize consequential damages in case of a fire?

How can you minimize consequential damages in case of a fire? How can you minimize consequential damages in case of a fire? With intelligent extinguishing solutions from Siemens. Sinorix 227 fast, effective, and reliable. Answers for infrastructure. Reliability the

More information

Notice on the implementation of the amendments to the FSS Code in resolution MSC.339(91)

Notice on the implementation of the amendments to the FSS Code in resolution MSC.339(91) C C S 通函 Circular China Classification Society (2013) Circ.111 /Total No.397 25/07/2013 (total pages:18) To relevant departments of CCS Headquarters, Shanghai Rules and Research Institute, plan approval

More information

Highly Protected Risks in Power Generation Stewart Kidd outlines the issues to consider when installing active fire suppression in power stations THE

Highly Protected Risks in Power Generation Stewart Kidd outlines the issues to consider when installing active fire suppression in power stations THE Highly Protected Risks in Power Generation Stewart Kidd outlines the issues to consider when installing active fire suppression in power stations THE TERM highly protected risk (HPR) is commonly used in

More information

Dräger Polytron 8310 IR Detection of flammable gases and vapour

Dräger Polytron 8310 IR Detection of flammable gases and vapour Dräger Polytron 8310 IR Detection of flammable gases and vapour The Dräger Polytron 8310 IR is an advanced explosion proof transmitter for the detection of combustible gases in the lower explosion limit

More information

Safer Fire Fighting. Efficient Fire Fighting. Saving Environment

Safer Fire Fighting. Efficient Fire Fighting. Saving Environment Safer Fire Fighting Efficient Fire Fighting Saving Environment Cold Cut Systems is the World leader in cold cutting extinguishing technology Cold Cut Systems is the sole supplier of the coldcut cobra cutting

More information

Water mist fire suppression systems. Minifog ProCon Low-pressure water mist system

Water mist fire suppression systems. Minifog ProCon Low-pressure water mist system Water mist fire suppression systems Minifog ProCon Minifog ProCon Low-pressure water mist system IRE PROTECTION Efficient even for non-enclosed equipment Minifog ProCon systems by Minimax use innovative

More information

Only the Danish version is authentic Notice D II-2 N(2) 1 October 2002 CHAPTER II-2 N(2)

Only the Danish version is authentic Notice D II-2 N(2) 1 October 2002 CHAPTER II-2 N(2) Only the Danish version is authentic Notice D II-2 N(2) 1 October 2002 Technical regulation on the construction and equipment, etc. of passenger ships on domestic voyages CHAPTER II-2 N(2) Construction,

More information

An Overview of Extinguishing Systems for Computer Equipment

An Overview of Extinguishing Systems for Computer Equipment Risk Solutions An Overview of Extinguishing Systems for Computer Equipment Various types of automatic suppression systems are available for protecting computer equipment. This report discusses the uses

More information

Crosswalk: Weight-Based Rating versus Performance-Based Rating

Crosswalk: Weight-Based Rating versus Performance-Based Rating 46 CFR 25.30 (Subchapter C) Motorboats Motorboat size Old New With no fixed fire With a fixed fire extinguishing System extinguishing system Motorboats under 16ft B-I 5-B 1 0 Motorboats 16ft-26ft B-I 5-B

More information

Dräger Polytron 8200 CAT Detection of flammable gases and vapors

Dräger Polytron 8200 CAT Detection of flammable gases and vapors Dräger Polytron 8200 CAT Detection of flammable gases and vapors The Dräger Polytron 8200 CAT is an advanced explosion proof transmitter for the detection of flammable gases in the lower explosion limit

More information

INTEGRATED PIPING SYSTEMS. The complete piping system with M-profile press fittings. VSH XPress

INTEGRATED PIPING SYSTEMS. The complete piping system with M-profile press fittings. VSH XPress INTEGRATED PIPING SYSTEMS The complete piping system with M-profile press fittings VSH INTEGRATED PIPING SYSTEMS VSH is the number one specialist for integrated piping systems. We provide our customers

More information

Fire Protection for Catering Kitchens KS 2000 Compact Extinguishing System. Safe for certain.

Fire Protection for Catering Kitchens KS 2000 Compact Extinguishing System. Safe for certain. SPECIAL EXTINGUISHING SYSTEMS COMPACT EXTINGUISHING SYSTEMS Fire Protection for Catering Kitchens KS 2000 Compact Extinguishing System Safe for certain. ISKS IDENTIFYING Catering kitchens tend to use large

More information

Global Marine Solutions. From Ship to Shore, single source providers for Fire Protection, Electronic Security, Life-Safety and Communications Systems

Global Marine Solutions. From Ship to Shore, single source providers for Fire Protection, Electronic Security, Life-Safety and Communications Systems Global Marine Solutions From Ship to Shore, single source providers for Fire Protection, Electronic Security, Life-Safety and Communications Systems Specialists in Fire, Security, Communications Systems

More information

Marine Boilers. From a world class boiler manufacturer

Marine Boilers. From a world class boiler manufacturer Marine Boilers From a world class boiler manufacturer Some like it hot. Some like it fast. We like it perfect. Parat Halvorsen has been family-run since day one, and acting like it ever since. To this

More information

Fire Suppression Systems

Fire Suppression Systems Fire Suppression Systems www.watermist.com Public Buildings Custodial Food Industry Transportation Power Generation The Hydramist product range was created to address fast, safe and efficient water based

More information

(Material correct at 1/11/2011)

(Material correct at 1/11/2011) NEBOSH International Diploma in Occupational Health & Safety Unit IC INTERNATIONAL WORKPLACE AND WORK EQUIPMENT SAFETY element IC3 WORKPLACE FIRE RISK ASSESSMENT Sample material (Material correct at 1/11/2011)

More information

(2) Various fire sections enclosed by various classes of fire divisions; (3) Arrangement of fire detectors and manual fire alarm stations;

(2) Various fire sections enclosed by various classes of fire divisions; (3) Arrangement of fire detectors and manual fire alarm stations; (1979) (Rev.1 1990) (Rev.2 1996) (Rev.3 Jan 2012) Safety features.1 Fire protection and extinction.1.1 General Fire protection arrangements and fire extinguishing systems are to be in accordance with the

More information

Fireward Fixed Fire Fighting System. For Open Areas & Enclosed Risks fireward.co.uk

Fireward Fixed Fire Fighting System. For Open Areas & Enclosed Risks fireward.co.uk Fireward Fixed Fire Fighting System For Open Areas & Enclosed Risks 0800 151 0249 Email: sales@fireward.co.uk fireward.co.uk Industry Specific Solutions At Fireward we pride ourselves in the provision

More information

security WHAT MAKES US DIFFERENT? We Place A Huge Importance On Integrity.

security WHAT MAKES US DIFFERENT? We Place A Huge Importance On Integrity. 2 firetech.com.mt 3 That sense of security WE BELIEVE THAT PEACE OF MIND IS PRICELESS WHAT MAKES US DIFFERENT? Firetech provide reliable fire, safety and security solutions that protect people, property,

More information

Products and performance

Products and performance Products and performance February 26, 2016 GfG Instrumentation overview of fixed system products Slide 1 GfG Instrumentation, Inc. 1194 Oak Valley Drive, Suite 20, Ann Arbor, Michigan 48108 Toll free (USA

More information

IMO INTERPRETATIONS OF FIRE PROTECTION-RELATED PROVISIONS OF THE HSC CODE

IMO INTERPRETATIONS OF FIRE PROTECTION-RELATED PROVISIONS OF THE HSC CODE INTERNATIONAL MARITIME ORGANIZATION 4 ALBERT EMBANKMENT LONDON SE1 7SR Telephone: 0171-735 7611 Fax: 0171-587 3210 Telex: 23588 IMOLDN G Ref. T4/4.01 IMO E MSC/Circ.911 4 June 1999 INTERPRETATIONS OF FIRE

More information

LOW EXPANSION FOAM FIRE EXTINGUISHING SYSTEM

LOW EXPANSION FOAM FIRE EXTINGUISHING SYSTEM LOW EXPANSION FOAM FIRE EXTINGUISHING SYSTEM EFFECTIVE PROTECTION OF OPEN SPACE AREAS Extinguishing fi res in open space areas on vessels can be challenging, as the effects of wind and a constant supply

More information

The Most Versatile Flame Detectors in the World. Optical Flame Detection Solutions

The Most Versatile Flame Detectors in the World. Optical Flame Detection Solutions The Most Versatile Flame Detectors in the World Optical Flame Detection Solutions The Global Leader in Flame Detection Superior Performance and Reliability Flame detection is the very essence of the proud

More information