A1UL PERS. Personal Emergency Response System. For Technical Support Please Contact Your Service Provider Or Distributor

Size: px
Start display at page:

Download "A1UL PERS. Personal Emergency Response System. For Technical Support Please Contact Your Service Provider Or Distributor"

Transcription

1 A1UL PERS Personal Emergency Response System

2

3 TABLE OF CONTENTS 1. READ THIS FIRST SYSTEM OVERVIEW COMPONENTS 2 4. UNIT OPERATION! Standby Mode.. 3! Emergency Activation. 3! Answering Incoming Calls. 4! AC Power Monitoring.. 4! Telephone Line Status Monitoring.. 5! Temperature Monitoring. 5! Mobility Timer.. 5! Low Battery Reporting Devices. 5! Low Battery Reporting Console. 6! No Devices Loaded. 6! Global Test Feature 6! Periodic Test Report INSTALLING THE UNIT PROGRAMMING THE UNIT! Programmable Options.. 7! Local Programming. 9! Remote Programming WIRELESS DEVICES! Adding Wireless Devices... 12! Deleting Wireless Devices. 12! Range Test Mode TECHNICAL INFORMATION. 13 Appendix A A1UL PERS Monitoring Center Defaults 14 Appendix B Resetting the Unit to Factory Defaults READ THIS FIRST Some important notes about the A1UL PERS: 1. The A1UL PERS cannot be activated wirelessly in an emergency until a WTRB/WTRA is added to it s memory. 2. The effective range of any wireless device used with the A1UL PERS is 75m (246 ft). Note that different materials used in the construction of buildings can reduce the range of the device. 3. The A1UL PERS should be tested regularly to ensure it s continued operation. Test all wireless devices used with the system. 4. The WTRX and WTRB automatically detect when their batteries are low. They will automatically transmit a low battery signal to the A1UL PERS every 12 hours once a low battery is detected. Once this point is reached, the battery has approximately 30 days of use left. Contact your distributor immediately to obtain a replacement transmitter. 2. OVERVIEW The A1UL PERS (Personal Emergency Response System) allows users to easily summon for assistance during a medical emergency or for additional security reasons. Users have the option of using the wireless pendant and wristband transmitter or the large, red EMERGENCY button on the console to activate the A1UL PERS. When activated the A1UL PERS will audibly notify the user that an activation has occurred by playing the Emergency message. The A1UL PERS also dials the telephone number of the central monitoring station (CMS) programmed during programming by the installer. At the time of programming, the programmer/installer has the option of selecting Digital only transmission (Non-Voice) to the CMS, or the two-way voice operation. If the Digital (Non-Voice) option is selected the unit will, following activation by the user, contact the CMS (as programmed by installer) and, after successfully connecting with the CMS, disconnect and reset itself. Please contact your CMS representative for dispatch procedures following a Digital transmission. If two-way voice mode is selected, after the signal is received by the CMS, an operator from the CMS will communicate with the user via the speaker and microphone contained within the A1UL PERS console. The user need not push the transmitter button again or pick up the telephone to communicate with the CMS operator once the A1UL PERS has been activated. The CMS operator will

4 disconnect and reset the A1UL PERS, the user will not have to manually reset the unit. During a false activation, the user can press the green RESET button on the console at any time to cancel an emergency activation and reset the system to standby mode. G H I J K L There are several programming methods available for programming the A1UL PERS. To program locally using the programming port located on the back of the unit, a special programming cord is available. Using the cord, the A1UL PERS can be programmed via a standard telephone with tone capabilities. Optional software is available for programming. The A1UL PERS is also equipped with the ability to program remotely from a location other than the primary residence of the user. The programming cord is not required for remote programming. Please refer to the manual for complete programming instructions. Other features of the A1UL PERS include: inactivity timer to monitor the activity of the user and notify the CMS if no activity is detected for a specified period of time; temperature sensor to monitor the temperature of the home and alert the CMS is temperatures become unsafe; telephone line detection to alert the user if the telephone line is disconnected from the unit or not working properly; power sensor to alert both the user and CMS if AC power is not being provided to the unit; battery supervision for both the personal transmitter and console, the CMS will be notified if battery conditions are low. 3. COMPONENTS A. Power LED (Green)! OFF - Unit has no power.! SOLID - AC power is applied.! FLASHING - AC power is lost. Unit is on battery backup. B. Alarm/Status LED (Red) Stand By Mode! OFF - Unit is in stand by mode.! FLASHING SLOWLY - The console backup battery is low.! FLASHING RAPIDLY - A wireless device used with the unit has a low battery. TOP VIEW F D E A B C Reporting To Monitoring Center! SOLID - Unit is reporting to the monitoring center.! FLASHING - The unit is currently in the 2- way voice mode. Incoming Call Answering (Speakerphone)! SOLID - The unit is currently in the speakerphone mode. REAR VIEW! OFF The unit has disconnected the current call.

5 C. RESET Button (Green)! Press it to cancel any alarm or status condition that is being sent to the monitoring center. Will send in a cancel signal if unit has already reached the monitoring center.! Will return unit to standby mode regardless of current state.! Used to reset the Inactivity Timer.! When pressed, the unit will play the status message(s) of any fault conditions present (such as a power failure or phone line problem).! The RESET button will stop the red Alarm/Status from blinking when a low battery condition exists.! Imprinted with Braille lettering for the visually impaired. D. EMERGENCY Button! Backlit for easy locating in low light conditions.! The backlight will flash identical to the Power LED.! Press to trigger a medical alarm.! Press once to answer an incoming call (if this feature is enabled)! Imprinted with Braille lettering for the visually impaired. E. Speaker G. Phone Jack Labeled This Plug To Wall Outlet! This jack should be connected directly to the residence s phone jack on the wall or floor.! This jack supports RJ-31x installations if used with the appropriate cable. H. Phone Jack Labeled Plug Phone Or Other Device Here! Plug the phone, answering machine caller ID box or other phone accessories into this jack. I. Temperature Sensor! Monitors the temperature of the residence.! Will report a high (105 F) or low (35 F) temperature signal to the monitoring center J. Programming Port! This port is used to connect the phone used for local programming. A special adaptor is required. K. Battery ON/OFF Switch! Turns the backup battery on or off.! Use this to shut the unit off if it is going to be unplugged for an extended amount of time.! WARNING If this switch is set to OFF and the AC power is lost, the unit will not be on battery backup. F. Microphone L. AC Power Adaptor

6 4. UNIT OPERATION Standby Mode While in Standby mode, the unit is ready to accept signals from any wireless device in its memory. Pressing the EMERGENCY button will activate the unit and it will begin reporting to the monitoring center while in Standby mode. Pressing the RESET button while the unit is in Standby mode will play the status messages of any fault conditions present at the time. Emergency Activation In an emergency, help can be summoned in one of two ways: 1. Pressing the personal help button (WTRB) that is worn by the client. 2. Pressing the EMERGENCY button on the console. Emergency Reporting Once activated, the unit will do the following:! It will begin playing the Emergency Help call in progress message repeatedly. It will stop once the A1UL PERS receives the Kiss-Off from the monitoring centers receiver.! The red Alarm/Status LED will light up while the signal is being reported to the monitoring center.! An alarm can be cancelled at any time by pressing the RESET button. The unit will play the Help call cancelled message. If the signal has already been reported to the monitoring center and 2-way voice has not been properly terminated, the unit will report a cancel by user signal to the monitoring center. attempt the backup number. It will alternate between the primary and backup numbers until it reaches a receiver successfully. It will make a maximum of 10 total dialing attempts. 2-Way Voice Operation Once the unit reports the alarm to the monitoring center successfully, it will do the following:! The red Alarm/Status LED will start to flash.! The unit will wait 2 minutes for the monitoring center operator to open 2-way voice. (If the 2- way voice feature is disabled in programming, the unit will simply hang up the line after reporting to the monitoring center).! The following DTMF commands are used to operate the 2-way voice: DTMF DIGIT COMMAND 1 Talk 3 Listen 2 Full-Duplex 9 Disconnect! If the A1UL PERS reports the alarm to the monitoring center successfully and the call is unexpectedly disconnected before any DTMF commands are issued to operate 2- way voice, the unit will dial the monitoring center again and report the emergency. The unit will keep resending the emergency until it receives at least one DTMF command.! The 2-way voice session has a time limit of 2 minutes. The timer is reset after any DTMF command is received. Answering Incoming Calls! If the A1UL PERS cannot reach the monitoring center on the primary phone number it will If enabled in programming, the A1UL PERS can be used to answer incoming phone calls. The unit will open up

7 into a full-duplex speakerphone in which the client does not have to pick up their normal phone.! The A1UL PERS will beep when it detects an incoming call.! The incoming call can be answered in one of two ways: 1. Press the button on any WTRX added to the system. 2. Press the HELP button on the console once.! The A1UL PERS will emit 2 beeps upon answering the incoming call.! The call can be disconnected one of two ways: 1. Pressing the button on any WTRX added to the system once. 2. Pressing the RESET button on the console.! The A1UL PERS will emit a single beep to indicate the call has been disconnected.! If there is an emergency at any time during the call, pressing the button on the WTRB twice or pressing the EMERGENCY button on the console once will disconnect the call and cause the unit dial the monitoring center and report the emergency.! There is a 30-minute time limit on each call. The unit will automatically disconnect after 30 minutes. AC Power Monitoring If enabled in programming, the A1UL PERS will continually monitor the status of the AC power to the unit.! If AC power is lost for more than 5 seconds, the unit will play the Power Failure- Check power cord status message twice. The green Power LED will begin to flash as well.! If AC power is not restored after 1 hour, the unit will report a power failure signal to the monitoring center.! Once AC power is restored for more than 5 seconds, the unit will play the Power restored status message once. The green Power LED will stop flashing.! Once AC power has been restored for more than 15 minutes (AND the A1UL PERS had previously sent a power failure signal to the monitoring center) the unit will report a power restoral signal to the monitoring center.! If AC power is lost, the A1UL PERS will automatically switch to battery backup. The unit can operate up to 24 hours on battery backup. NOTE: The backup battery takes 48 hours to charge completely. Telephone Line Status Monitoring The A1UL PERS continuously monitors the status of its connected phone lines.! If the telephone line is unplugged or the voltage on the line drops to 3.0 VDC for 15 consecutive seconds, the unit will play the Telephone line problem Check telephone connection status message twice.! Once the telephone connection is restored or the voltage is above 3.0 VDC for more than 15 seconds, the unit will play the Telephone line Restored message once.! If there is a problem with the wiring in a residence, the A1UL PERS may falsely report a problem with the phone line. This feature can be disabled in programming if needed. Temperature Monitoring

8 The A1UL PERS is equipped with a built in thermometer that continuously monitors the surrounding temperature.! If the temperature reaches 105 F (40 C) or higher, the unit will do the following: 1. Play the Temperature warning Unsafe Temperature Warning status message twice. 2. Report a high temperature alarm to the monitoring center.! If the temperature reaches 35 F (2 C) or lower, the unit will do the following: 1. Play the Temperature warning Unsafe Temperature Warning status message twice. 2. Report a low temperature alarm to the monitoring center.! Once the temperature returns to a safe level, the unit will report the appropriate temperature restoral (high/low) to the monitoring center. Mobility Timer If enabled in programming, the mobility timer will monitor the activity of the protected client. It is basically a timer that counts down. Every time the client interacts with the system, the timer restarts. If the timer ever expires without being reset, the A1UL PERS will report an inactivity alarm to the monitoring center. The length of the mobility timer is set in programming.! The following events reset the mobility timer: 1. The client presses the RESET button on the console. 2. The client activates an emergency call by either pressing the EMERGENCY button on the console or by activating their emergency pushbutton. 3. The A1UL PERS receives a signal from an optional PIR motion detector.! One hour before the timer is about to expire, the unit will play the Mobility timer expiring Please reset every five minutes.! If the timer expires without being reset, the unit will report an inactivity alarm to the monitoring center. Low Battery Reporting Devices Some devices automatically detect and send low battery signals to the A1UL PERS. Other devices only report low battery signals when they are activated. The table below lists the devices available for use with the A1UL PERS and their low battery reporting method: DEVICE WTRB/WTRX WTRA SD-7 Smoke Detector IR-7 Motion Detector METHOD Automatically Every 12 hours Upon activation Upon activation Upon activation When the A1UL PERS receives a low battery signal from one of it s devices, it will do the following:! The unit will beep 4 times. This will occur every time it receives a low battery signal.! The red Alarm/Status LED will flash rapidly. Pressing RESET will stop the flashing.! The unit will report the low battery condition to the monitoring center. It will report the zone of the device that has the low battery. Low Battery Reporting Console The A1UL PERS monitors the status of it s internal backup battery. It does not monitor the battery for 30 minutes after power up. If a low battery is detected in the console, the unit will do the following:! The unit will beep 2 times.

9 ! The red Alarm/Status LED will begin to blink slowly. The blinking can be stopped by pressing the RESET button on the console.! The unit will report the low battery condition to the monitoring center.! Once the battery has returned to a normal level, the unit will report a battery restoral signal to the monitoring center. No Device Loaded The A1UL PERS will report a No Transmitter Loaded signal to the monitoring center 30 minutes after power up if there are no devices loaded into it s memory. Global Test Feature If enabled in programming, the A1UL PERS will run a self-check and report to the monitoring center if it passes. The Global Test is initiated by pressing RESET on the console and within 5 seconds activating a WTRB or WTRA that is loaded into memory.! Generally the unit should be programmed and tested before being placed in a client s home.! Refer to the section on programming the unit on page # 7. 2) Choose the Location of the Unit! The unit can be placed on a tabletop or other flat surface. It can also be mounted on a wall using the included mounting bracket.! The unit should be centrally located in the residence. This will ensure adequate coverage for both the wireless devices and the 2-way voice operation.! The unit should not be placed near microwaves or any other large appliances.! The unit should not be placed in locations where extremes in temperature are present (such as by radiators or heaters, near an air conditioner, in direct sunlight etc.) Periodic Test Report If enabled in programming, the A1UL PERS can send in automatic check-in reports to the monitoring center at a specified frequency. The frequency at which they are sent is set in programming. 3) Connect the Unit POWER! WARNING Do NOT plug the unit into an outlet that can be operated by a switch.! Only use the power supply that is included with the unit. 5. INSTALLING THE UNIT Installing the A1UL PERS is a simple procedure. Below is a quick list of the steps needed to install it. 1) Program the unit TELEPHONE! The jack labeled This Jack To Wall Outlet should be connected directly to the phone jack on the wall or the floor.! If the residence has older wiring, a 2- conductor telephone cord should be used. (This cord is provided with every unit). A 4- conductor cord could cause noise and

10 interference to the phone line in the residence.! If the client has DSL service in the residence, a DSL line filter may be required to connect the unit to the phone line. 4) Add Wireless Devices to the Unit! Any wireless device that is going to be used with the system must first be added to the unit s memory before it will activate the unit. 5) Test the Unit! The unit should always be tested after installation.! Test all devices that are added to the unit. This ensures complete operation of the system.! NOTE: Be sure to follow the procedures set in place by your monitoring station for testing a new unit. A) PROGRAMMABLE OPTIONS There are several options that can be set during the programming of the A1UL PERS. The A1UL PERS can be programmed locally using the programming port with a special adaptor or remotely from any touch-tone phone. There are two levels of programming in the A1UL PERS. Certain options are set in either level 1 or level 2 of the programming. Programming is done by pressing the key on the phone that corresponds to the desired setting for that option. The programming is automatically incremented to the next option when a selection is made. Below is a description of the options that are set during programming, their available settings and whether they are in the first or second level of programming 1) Inactivity Timer LEVEL 1 The Inactivity Timer can be used to monitor the activity of the protected client. If the set length of time expires and the A1UL PERS has not detected any activity from the client, it will report an Inactivity Alarm to the monitoring center.! Option #1 in 1 st Level. 6. PROGRAMMING This section is broken down into three parts: A. PROGRAMMABLE OPTIONS This lists all the options that can be set in programming and their choices. B. LOCAL PROGRAMMING Describes the process of programming the A1UL PERS locally using a programming phone.! SETTINGS 2) Dialing Method KEY SETTING 0 Disabled 1 12 Hours 2 24 Hours This option sets the dialing method of the A1UL PERS.! Option #2 in 1 st Level C. REMOTE PROGRAMMING Describes the process of programming the A1UL PERS from a remote location using the phone! SETTINGS line. KEY SETTING 1 Pulse Dialing 2 Touch-Tone Dialing

11 3) Message ON/OFF and Temperature Sensor ON/OFF This option controls 2 features. The voice messages that are played by the A1UL PERS can be turned on or off here. This is for ALL of the messages. They are either all on or all off. The second feature that can be turned on or off is the temperature detection..! Option #3 in 1 st Level! SETTINGS KEY SETTING MSG. PLAY TEMP DET. 1 ON ON 2 OFF ON 3 ON OFF 4 OFF OFF 4) AC Power Monitoring and Global Test This option covers three operations of the A1UL PERS. The first is the AC power failure and restoral monitoring; the second is the telephone line status monitoring, third is the Global Test feature. If enabled, the A1UL PERS will monitor the AC power for the unit. If it is lost, the unit will play a warning message and report the failure to the monitoring center. Once AC power is restored, the A1UL PERS will report it to the monitoring center. If this feature is disabled, the unit will NOT monitor for AC power loss and the unit will play no warning message if AC is lost. This feature should only be disabled in areas that experience frequent temporary brownouts or blackouts or in other exceptional circumstances. If enabled, the A1UL PERS will continuously monitor the status of the telephone line. In some homes with multiple phones and/or poor wiring, the A1UL PERS may falsely detect a problem with the phone line. If this is true, the phone line status monitoring can be disabled in programming. The Global Test features is activated by pressing the RESET button on the A1UL PERS and within 5 seconds activate any wireless push button that is in the units memory. The unit will emit a short beep, perform a self test of itself and, if it passes, send the Global Test signal to the monitoring center. If this feature is disabled, the unit will report an emergency signal to the monitoring center whenever a pushbutton is activated regardless of when RESET was pressed.! Option #4 in 1 st Level! SETTINGS KEY SETTING AC Monitoring Global Test Phone Line Status 1 ON ON ON 2 OFF OFF ON 3 OFF ON ON 4 ON OFF ON 5 ON ON OFF 6 OFF OFF OFF 7 OFF ON OFF 8 ON OFF OFF 5) 2-Way Voice ON/OFF This option determines whether or not the A1UL PERS will wait for the monitoring center operator to open 2-way voice after reporting any alarms. If set to OFF the unit will act as a digital communicator only.! Option #5 in 1 st Level! SETTINGS 6) Account Number KEY SETTING 1 2-Way Voice ON 2 2-Way Voice OFF

12 After entering the first 5 options, enter the unit s 4- digit account number next. The account number must be exactly 4 digits. 7) Primary Monitoring Center Phone Number After entering the account number, the primary phone number to the monitoring center is next.! The phone number can be between 1 and 15 digits.! If a 9 or other number is required to obtain an outside line, place it at the start of the phone number.! Enter a * in the phone number to add a 3 second pause in the dialing. As many * as needed can be entered. 8) End Of Phone Number Character After entering the last digit of the phone number, press the # key. This saves all the changes made to the programming and returns to the start position of the programming mode. 1) Press 7 LEVEL 2 Pressing 7 from the programming start position enters the second level of programming. 2) Periodic Test Feature If enabled, the Periodic Test feature will dial in and report to the monitoring station at a specified frequency. This verifies the correct operation of the phone line and that the A1UL PERS has power.! Option #1 in 2 nd Level KEY SETTING 0 Disabled 1 Every 1 day 2 Every 7 days 3 Every 28 days 3) Incoming Call Answering If enabled, this feature allows the protected client to answer an incoming call by simply pressing their personal help button or the EMERGENCY button on the console. During an incoming call, the unit will beep to alert the client of the call. If disabled, the unit will remain silent during an incoming call and the client will not be able to answer it using the above method.! Option #2 in 2 nd Level! SETTINGS KEY SETTING 0 Disabled 1 Enabled 4) Backup Monitoring Center Phone Number Enter the backup number to the monitoring center that will be dialed if the A1UL PERS is unable to make contact on the primary number.! The phone number can be between 1 and 15 digits.! If a 9 or other number is required to obtain an outside line, place it at the start of the phone number.! Enter a * in the phone number to add a 3 second pause in the dialing. As many * as needed can be entered 5) End Of Phone Number Character! SETTINGS

13 After entering the last digit of the phone number, press the # key. This saves all the changes made to the programming and returns to the start position of the programming mode. LOCAL PROGRAMMING Programming the first level options: The following equipment is needed for local programming: Using the keys on the programming phone, enter the first level options:! Programming Port Adaptor! Any telephone that is capable of dialing using touch-tones (DTMF) To enter local programming mode: Step 2 - Step 4 - Connect the phone to the programming port on the rear of the unit using the programming port adaptor. The phone should be set to TONE dialing. Take the receiver on the programming phone off-hook. Press and hold the RESET button on the A1UL PERS. Hold RESET until the unit emits a double-beep (about 15 seconds) Release the RESET button. The red Status/Alarm LED will flash to indicate the unit is in programming mode. NOTES ON PROGRAMMING:! There is a 15 second time limit between options. If 15 seconds elapses from the last entry, the unit will disregard any changes made and exit programming mode to the Standby mode.! Pressing the # key twice at any time while in the programming mode will cause the unit to exit to the Standby mode.! Inactivity Timer (0,1,2)! Dialing Method (1,2)! Emergency Message (1, 2)! AC Power Monitoring and Global Test (1,2,3,4)! 2-Way Voice ON/OFF (1,2)! Account Number! Primary Monitoring Center Phone Number NOTE: If an invalid key is pressed for an option, the unit will emit a long beep. Re-enter a correct value for that option. NOTE: The programming mode automatically starts at the first option. After a valid value is entered, the unit automatically increments to the next option. Step 2 - After entering the last digit of the phone number, press the # key. The unit will save the changes made and will return to the programming start position. Step 4 - Proceed to the next section to program the second level options. If finished with programming, pressing the # key again will exit the programming mode and return the unit to the Standby mode. The unit will emit two short beeps and the Status/Alarm LED will stop flashing to indicate it is in Standby mode. Programming the second level options:

14 From the programming start position, press the 7 key on the programming phone. 2. An access code must be entered before the unit will enter programming mode. 3. Remote programming can be done off-site. Step 2 - Using the keys on the programming phone, enter the second level options: The A1UL PERS must be hooked up correctly to an active phone line.! Periodic Test (0,1,2,3)! Incoming Call Answering (0,1)! Backup Monitoring Center Phone Number NOTE: If an invalid key is pressed for an option, the unit will emit a long beep. Re-enter a correct value for that option. If finished with programming, pressing the # key again will exit the programming mode and return the unit to the Standby mode. The unit will emit two short beeps and the Status/Alarm LED will stop flashing to indicate it is in Standby mode. Changing The Remote Programming Access Code: The remote access code is a 3-digit code that must be entered to access the programming mode remotely. The factory default code is 111. NOTE: If the access code starts with a 0 (zero) the remote programming feature will be DISABLED. Step 2 - From the programming start position, press 8. Enter the new 3-digit access code. Step 2 - Step 4 - Step 5 - Call the line that the A1UL PERS is hooked up to. Answer the call using one of the phones on the line (preferably the one hooked into the jack labeled Plug Phone Or Other Device Here ) Once a connection is established, have the client press and hold RESET on the unit until the double beep is heard. The unit will emit a beep locally and through the phone line. At this point enter the current 3-digit access code. If the code is correct, the unit will play a single beep over the phone. This indicates that the unit is at the programming start position. The unit will not respond with any beeps if the wrong code is entered. NOTE: If an incorrect code is entered, the unit will not respond. A maximum of 3 incorrect entries can be made. After that, the unit will exit to the Standby mode. Step 6 - Proceed to program the unit: Programming the first level options: Press the * key to save the new code. Using the keys on the programming phone, enter the first level options: REMOTE PROGRAMMING Remote programming is very similar to local programming with three exceptions: 1. The programming port adaptor is not needed.! Inactivity Timer (0,1,2)! Dialing Method (1,2)! Emergency Message (1, 2)! AC Power Monitoring and Global Test (1,2,3,4)! 2-Way Voice ON/OFF (1,2)! Account Number

15 ! Primary Monitoring Center Phone Number NOTE: If an invalid key is pressed for an option, the unit will emit a long beep. Re-enter a correct value for that option. NOTE: The programming mode automatically starts at the first option. After a valid value is entered, the unit automatically increments to the next option. Step 2 - Step 4 - After entering the last digit of the phone number, press the # key. The unit will save the changes made and will return to the programming start position. Proceed to the next section to program the second level options. If finished with programming, pressing the # key again will exit the programming mode and return the unit to the Standby mode. The unit will emit two short beeps and the Status/Alarm LED will stop flashing to indicate it is in Standby mode. Programming the second level options: Step 2 - From the programming start position, press the 7 key on the programming phone. Using the keys on the programming phone, enter the second level options:! Periodic Test (0,1,2,3)! Incoming Call Answering (0,1)! Backup Monitoring Center Phone Number Re-enter a correct value for that option. If finished with programming, pressing the # key again will exit the programming mode and return the unit to the Standby mode. The unit will emit two short beeps and the Status/Alarm LED will stop flashing to indicate it is in Standby mode. Changing The Remote Programming Access Code: The remote access code is a 3-digit code that must be entered to access the programming mode remotely. The factory default code is 111. NOTE: If the access code starts with a 0 (zero) the remote programming feature will be DISABLED. Step 4 - Step 5 - Step 6 - From the programming start position, press 8. Enter the new 3-digit access code. Press the * key to save the new code. 7. WIRELESS DEVICES A number of different wireless devices can be added to the A1UL PERS. A total of 15 of these can be loaded into the unit. A device will not activate the unit until it is learned into it. Adding A Device Press and hold RESET on the A1UL PERS until the second beep. (About 5-7 seconds). NOTE: If an invalid key is pressed for an option, the unit will emit a long beep.

16 Step 2 - After the second beep, let go of the RESET button. Press and hold the EMERGENCY button. To enter Range Test mode: Step 4 - While holding down the EMERGENCY button, press the button on the device to be added. The unit will emit 2 short beeps. Release the EMERGENCY button The device is successfully added. If only one beep is heard, the device has already been added to the system. Repeat steps 2 and 3 for each device that is to be added. Step 2 - Press and hold RESET on the A1UL PERS until the second beep. (About 5-7 seconds). After the second beep, the unit is in Range Test mode. Activate any wireless device that has been added to the unit. Every time the unit receives a signal from a device it will emit a beep without attempting to contact the monitoring center. Step 5 - Press the RESET button once to return to Standby mode. NOTE: The unit will automatically return to Standby mode after 5 minutes of inactivity. Deleting Devices Step 4 - When finished, press the RESET button once to return to Standby mode.! The A1UL PERS will automatically return to Standby mode if it does not receive any RF signals in 5 minutes. WARNING: This will erase all devices loaded into the A1UL PERS! Step 2 - Step 4 - Press and hold RESET on the A1UL PERS until the second beep. (About 5-7 seconds). After the second beep, let go of the RESET button. Press and hold the EMERGENCY button for 45 seconds. After 45 seconds, the unit will emit a long beep. At this point, all devices have been erased from memory. Press RESET to return to Standby mode. Range Test The range test can be used to test the RF range of any wireless devices that are added to the A1UL PERS.

17 DTMF or pulse dialing; pulse speed (10 PPS, Dialing: 60% break, 40% make) Ringer Equivalence: 0.4 B Reporting Formats: Ademco Contact ID Telephone Primary, backup. Numbers: 8. Technical Information Reports: Dimensions: Weight: Full transmitter reports, console reports, general system reports, and inactivity PHYSICAL 8.27 x 6.44 x 2.87 in (210 x x 73 mm) 3 lbs. (1.45 kg) Primary Operating Voltage: Transformer: Back-Up Battery: Standby Current: Alarm Current: Backup Operation: Type: Operating Frequency RF Sensitivity: RF Range: Transmitter Capacity: RF Programming Method: Radio Zones: Control Switches: Indicators: Inputs: Programming Method: Audio: ELECTRICAL 120 VAC, 60 Hz UL listed, Class II, plug-in, 15VDC, 500mA (supplied) (1) 9.6V, 600mAh Ni-mh battery x 8 cells 70 ma 200 ~ 300 ma 22 hours minimum RADIO RECEIVER Diversity, dual super-heterodyne MHz 100M line of sight; 75M in structures 10 devices. Auto-learn. CONSOLE 10 supervised EMERGENCY with Braille RESET with Braille Red LED labeled "Alarm/Status" Green LED labeled "Power" (2) RJ-11In and out telephone jacks and a connection terminal for the local programming telephone set. Local or remote programming via normal telephone set. (8) voice prompt messages (5) types of beeps. 2-way voice manual 2-way voice Full-Duplex Speakerphone Silent Alarm Programmable. Feature: Pulse/Tone Dialing: Programmable. Operating 35 to 105 F (2 to 40 C) Temperature: Regulatory: FCC, DOC, ETL 1637 COMMUNICATOR

18 Appendix A A1UL PERS Monitoring Center Defaults Contact ID Codes EVENT/SIGNAL DESCRIPTION CONTACT ID REPORT OPEN CODE ZONE 2-WAY? Pendant Sent in immediately when client presses button on WTRX/WTRA/WTRB. E101 xxx * Yes EMERGENCY Button Sent in immediately when client presses the red EMERGENCY button on the console. E Yes Smoke Detector Sent in immediately when unit receives a signal from a smoke detector in it s memory. E110 xxx * Yes Mobility Timer Expired Sent in when Mobility Timer has expired. No client activity has been detected in the set time period. E Yes Low Temp. Sent in after a low temperature (<35 F) has been detected for one consecutive minute. E No Low Temp. Restoral Sent in after temperature returns to a normal level for one consecutive minute. R No High Temp. Sent in after a high temperature (>105 F) has been detected for one consecutive minute. E No High Temp. Restoral Sent in after temperature returns to a normal level for one consecutive minute. R No AC Power Failure Sent in after AC power has been absent to the unit for 1 consecutive hour. E No AC Power Restore Sent in after AC power has been restored to the unit for 15 consecutive minutes AND an AC power failure signal was previously reported. R No Low Battery Console Sent in immediately upon detecting a low battery in the console. Note The A1UL PERS does not monitor the status of it s internal battery for the first 30 minutes after being powered up. E No Sent in after the A1UL PERS s internal battery has returned to a normal level Low Battery Console for one consecutive minute AND a low battery console signal was previously Restoral reported. R No Low Battery Pendant/Necklace Transmitter Low Battery Smoke Detector Low Battery Smoke Detector Restoral Low Battery PIR Motion Detector Low Battery PIR Motion Detector Restoral Sent in immediately upon receipt of a low battery from a WTRA/WTRX/WTRB. The WTRX and WTRB automatically report a low battery upon detection. The WTRA is unsupervised and will only send a low battery when it is activated by pressing the button. E384 xxx * No Sent in immediately upon receipt of a low battery from a smoke detector. E384 xxx * No Sent in once the A1UL PERS receives an activation from the smoke detector that does not have a low battery signal with it (generally after the batteries have been replaced in the smoke detector) R384 xxx * No Sent in immediately upon receipt of a low battery from a PIR motion detector. E384 xxx * No Sent in once the A1UL PERS receives an activation from the motion detector that does not have a low battery signal with it (generally after the batteries have been replaced in the motion detector) R384 xxx * No

19 No Transmitter Loaded Automatic Check In Report Global Test Function Listen In Active The A1UL PERS checks to see if any wireless transmitters are in it s memory 30 minutes after power up. If none are present, the unit immediately sends a no transmitter loaded report. The unit will send a no transmitter loaded report any time all wireless devices are erased from it s memory. If enabled in programming, the A1UL PERS will automatically send in the automatic check-in report at the set intervals. If enabled in programming, pressing any pendant transmitter within 5 seconds of pressing RESET on the console will cause the A1UL PERS to send a Global Test report If a report that is sent to the monitoring center requires 2-way voice to be opened, the listen in active signal will be reported immediately following to indicate that 2-way voice is needed. E No E No E611 xxx * No E606 xxx * NA *= xxx represents the wireless zone of the device that generated the report. 2-Way Voice Commands COMMAND KEY TALK 1 LISTEN 3 FULL-DUPLEX 2 DISCONNECT 9 Appendix B Resetting The Unit To Factory Defaults!!! WARNING!!! This procedure will delete all wireless devices from the A1UL PERS and will erase all programming information including the monitoring center phone numbers. Step 2 - Step 4 - Step 5 - Step 6 - Unplug the AC adaptor and turn the backup battery switch OFF. With the unit completely powered down, press and hold both the RESET and EMERGENCY buttons. With the buttons held down, apply power to the unit. It will emit a shrill buzzing sound. After 5 seconds, release the RESET and EMERGENCY buttons. Press the RESET button once and wait for the beep. Press the RESET button again and the unit will emit a double beep to indicate it has been reset to it s factory defaults.

PERS-3600 PERSONAL EMERGENCY REPORTING SYSTEM INSTALLATION & OPERATION INSTRUCTIONS

PERS-3600 PERSONAL EMERGENCY REPORTING SYSTEM INSTALLATION & OPERATION INSTRUCTIONS PERS-600 PERSONAL EMERGENCY REPORTING SYSTEM BY BY INSTALLATION & OPERATION INSTRUCTIONS (760) 8-7000 USA & Canada (800) -587 & (800) 9-0 Toll Free FAX (800) 68-0 www.linearcorp.com CONTENTS CONTROL AREA

More information

ERS-3600B. PERS-3600B Personal Emergency Reporting System

ERS-3600B. PERS-3600B Personal Emergency Reporting System PERS-3600B Personal Emergency Reporting System ERS-3600B A Complete Emergency System For Comprehensive Care The Linear PERS-3600B includes a built-in speakerphone and reminder message capability, providing

More information

l 02-April-2010 For INSTANT CARE

l 02-April-2010 For INSTANT CARE l 02-April-2010 For INSTANT CARE Table of Contents 1. Application Overview 1 1.1. Identifying The Parts 1 1.2. The Power Supply 3 1.3. Line Capture 3 1.4. Line Failure Detection 4 1.5. How to install the

More information

1. Introduction. 2. Product overview

1. Introduction. 2. Product overview 1. Introduction The AG400011 GSM Alarm panel is a control panel that is compatible with other H-net security devices from Everspring, such as wireless sensors, remote keyfobs, tags, and keypad. With this

More information

WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER

WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER BAT.LOW AC WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER THE SYSTEM THAT CALLS YOU! Our WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER is designed to allow you to create your own security system.

More information

Destiny Destiny Owners Manual

Destiny Destiny Owners Manual Destiny 4100 Destiny 4100 Owners Manual TABLE OF CONTENTS INTRODUCTION Control Panel...3 Detection Devices...3 Telephone Keypads...3 GLOSSARY... 4-5 LOCAL PHONE ACCESS Using Your Telephones As Keypads...6

More information

Security System. User Guide for the LED Command Center

Security System. User Guide for the LED Command Center Security System User Guide for the LED Command Center National Security Systems Inc (800)457-1999 MY SECURITY COMPANY IS: CALL BEFORE TEST: THIS SECURITY SYSTEM IS CONNECTED TO TELEPHONE NUMBER: THE SECURITY

More information

CONTENTS. (User s Manual)

CONTENTS. (User s Manual) CONTENTS (User s Manual) 1. Foreword & Main Features & Brief introduction of the Product 2. Understanding of Alarm Host 3. Specifications 4. Type and definition of Defense Line 5. Programming the alarm

More information

User s Guide. SUB-MA7240O-0001.OG.Solution doc. Created: 6/05/03. Last Updated: 23/09/03. MA7240AO-0001 Version 1.0

User s Guide. SUB-MA7240O-0001.OG.Solution doc. Created: 6/05/03. Last Updated: 23/09/03. MA7240AO-0001 Version 1.0 User s Guide SUB-MA7240O-0001.OG.Solution40-111.doc Created: 6/05/03 Last Updated: 23/09/03 MA7240AO-0001 Version 1.0 2 Table Of Contents User List...6 Quick Reference..7 Features...7 Keypad User's Guide...8

More information

Security System. User s Guide for the Text Command Center

Security System. User s Guide for the Text Command Center User s Guide for the Text Command Center MY ALARM COMPANY IS: CALL BEFORE TEST: THIS SECURITY SYSTEM IS CONNECTED TO TELEPHONE NUMBER: THE SECURITY CONTROL PANEL IS CONNECTED TO THE PHONE JACK LOCATED:

More information

Independent Living without Leaving Home. Personal Emergency Reporting Systems from Linear

Independent Living without Leaving Home. Personal Emergency Reporting Systems from Linear Independent Living without Leaving Home Personal Emergency Reporting Systems from Linear Connected and Reliable You can live in your own home independently, safe, secure and free from worry. Assistance

More information

Elite 16D Version 16 Zone Controller Arrowhead Alarm Products Ltd. Operating Guide. Proudly Designed and Manufactured in New Zealand

Elite 16D Version 16 Zone Controller Arrowhead Alarm Products Ltd. Operating Guide. Proudly Designed and Manufactured in New Zealand 6 Elite 16D Version 16 Zone Controller Arrowhead Alarm Products Ltd Operating Guide 1 Proudly Designed and Manufactured in New Zealand CONTENTS Page No. INTRODUCTION 3 About your Alarm 3 OPERATING YOUR

More information

Elite 64 Version 64 Zone Controller Arrowhead Alarm Products Ltd. Operating Guide. Proudly Designed and Manufactured in New Zealand

Elite 64 Version 64 Zone Controller Arrowhead Alarm Products Ltd. Operating Guide. Proudly Designed and Manufactured in New Zealand 2 Elite 64 Version 64 Zone Controller Arrowhead Alarm Products Ltd Operating Guide Proudly Designed and Manufactured in New Zealand 1 CONTENTS Page No. INTRODUCTION 3 About your Alarm 3 OPERATING YOUR

More information

All-In-One Wireless Security System V3.2 Programming Guide. Model # MG6130 / MG6160

All-In-One Wireless Security System V3.2 Programming Guide. Model # MG6130 / MG6160 All-In-One Wireless Security System V3.2 Programming Guide Model # MG6130 / MG6160 We hope this product performs to your complete satisfaction. Should you have any questions or comments, please visit www.paradox.com

More information

Contents. Glossary

Contents. Glossary Contents Glossary ------------------------------------------------------------------------------------------------------ 6 1. Introduction to the IDS 1632 -------------------------------------------------------------

More information

MEDI-CALL UNIT INSTALLATION MANUAL. Medi-Call V2.0 - V2.7 Installation Manual

MEDI-CALL UNIT INSTALLATION MANUAL. Medi-Call V2.0 - V2.7 Installation Manual MEDI-CALL UNIT INSTALLATION MANUAL Medi-Call V2.0 - V2.7 Installation Manual Copyright SmartLink International Pty Ltd February 2006 475 Nepean Highway, Brighton VIC 3186 Australia Telephone: +61 3 9596

More information

AXI LED USER MANUAL (REV. 1.0)

AXI LED USER MANUAL (REV. 1.0) Security & Home Automation System AXI LED USER MANUAL (REV. 1.0) CONTENTS PREFACE FEATURES LED KEYPAD OUTLOOK 1.0 LIGHT INDICATION 1 2 4 6 CHAPTER 1: ALARM SYSTEM CONTROL 1.0 USING LED KEYPAD 1.0.1 ARMING

More information

Supervised Security System Owner's Guide

Supervised Security System Owner's Guide Owner's Guide PSC06 READ THIS FIRST This equipment generates and uses radio frequency energy, and if not installed and used properly, that is, in strict accordance with the manufacturers instructions,

More information

PROGRAMMING PROCEDURES (Table 3)

PROGRAMMING PROCEDURES (Table 3) CONDOPLEX 2600/2600A/2700 Suite Panel User Manual Document Version 8.4 Oct 19, 1998 Condoplex 1998 PROGRAMMING PROCEDURES (Table 3) FUNCTION PRESS KEYPAD DISPLAY Delete user code or duress code. 0 (hold)

More information

Rev C May GE Interlogix. Part No: R. CareGard. User Guide

Rev C May GE Interlogix.   Part No: R. CareGard. User Guide g 466-1936 Rev C May 2003 GE Interlogix www.ge-interlogix.com Part No: 60-883-95R CareGard User Guide FCC Notices FCC Part 15 Information to the User Changes or modifications not expressly approved by

More information

Alarm Control Panel WIC-16Z4P WIC-5Z2P. Installation & Operation User Manual

Alarm Control Panel WIC-16Z4P WIC-5Z2P. Installation & Operation User Manual WIC-16Z4P WIC-5Z2P Installation & Operation User Manual Page : 1/34 INDEX # Function Page 1 Abort Current Communication and Clear Reporting Queue (*59) 13 2 Abort Current Communications (*59) 10 3 Account

More information

Quick Installation Manual LED Touch Keypad Autodial Wireless Alarm System

Quick Installation Manual LED Touch Keypad Autodial Wireless Alarm System Quick Installation Manual LED Touch Keypad Autodial Wireless Alarm System By shield4u http:// (Version 20110816) A. Alarm Understanding Away Disarm Home Emergency Function Signal Interpretation Buzzer

More information

DESTINY 6100 SERIES SECURITY SYSTEM OWNER S MANUAL V1 12/01

DESTINY 6100 SERIES SECURITY SYSTEM OWNER S MANUAL V1 12/01 DESTINY 6100 SERIES SECURITY SYSTEM OWNER S MANUAL 800-6006V1 12/01 System Overview General Information Control Panel Detection Devices You have made a wise decision to protect your family and property

More information

FreezeAlarm Dialer Pro

FreezeAlarm Dialer Pro FreezeAlarm Dialer Pro User Manual for FA-800E Thank you for purchasing our FreezeAlarm Dialer Pro. This instruction manual covers installation for model FA-800E. General Description The FA-800E automatically

More information

2000 Series. Program Entry Guide. Control Panels

2000 Series. Program Entry Guide. Control Panels 2000 Series EN Program Entry Guide Control Panels 2000 Series Program Entry Guide About This Manual EN 2 About This Manual This guide describes the programming parameters available to the 2000 Series Control

More information

ICP-CC488 ICP-CC488 EN. Control Panel. User s Guide

ICP-CC488 ICP-CC488 EN. Control Panel. User s Guide ICP-CC488 EN User s Guide ICP-CC488 Control Panel ICP-CC488 User's Guide Notices EN 2 Copyright Notice Unless otherwise indicated, this publication is the copyright of Bosch Security Systems, Inc. ( Bosch

More information

Voice Board. Installation and Programming Guide. Runner 4/8,PowerWave 4/8/16 &, Elite64. Add-on Board For Storing Recorded Voice Messages

Voice Board. Installation and Programming Guide. Runner 4/8,PowerWave 4/8/16 &, Elite64. Add-on Board For Storing Recorded Voice Messages ELECTRONIC ENGINEERING LTD. Voice Board Runner 4/8,PowerWave 4/8/16 &, Elite64 Add-on Board For Storing Recorded Voice Messages And listen-in. Installation and Programming Guide. P/N 7101372 Rev. C V.K

More information

Control Panel. Operators Manual TO SUIT AS216 KEYPAD. AS216-OM-6.2. Advanced Digital Controls

Control Panel. Operators Manual TO SUIT AS216 KEYPAD.   AS216-OM-6.2. Advanced Digital Controls Control Panel Operators Manual TO SUIT AS216 KEYPAD AS216-OM-6.2 Ultra-16 Control Panel AS216 OPERATORS MANUAL Copyright 2002 by NZ Ltd Auckland, New Zealand Document Part Number: This document is provided

More information

RANGER 7600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

RANGER 7600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL RANGER 7600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL TABLE OF CONTENTS 1. TABLE OF CONTENTS... P.1 2. GENERAL DESCRIPTION... P.2... 3. STANDARD AND OPTIONAL PARTS LIST... P.2... 4. FEATURE

More information

Automatic Phone-Out Home Monitoring Systems

Automatic Phone-Out Home Monitoring Systems Automatic Phone-Out Home Monitoring Systems Power Outage, Freeze and Flood Alarm Product Description Model Number: THP201 These monitoring systems are intended to monitor homes, cabins, and other premises

More information

PiSector GSM Cellular Wireless Alarm System

PiSector GSM Cellular Wireless Alarm System PiSector GSM Cellular Wireless Alarm System User Manual ( GS08 ) Read manual fully before use. PiSector Inc., USA, www.pisector.com Welcome to PiSECTOR Thank you for choosing PiSECTOR. Everyone at PiSECTOR

More information

Version 1.03 January-2002 USER S MANUAL

Version 1.03 January-2002 USER S MANUAL Version 1.03 January-2002 1 USER S MANUAL 2 Version 1.03 January-2002 System Details CUSTOMER:...... PHONE:... FAX:... INSTALLED BY:...... PHONE:... FAX:... MAINTENANCE & SERVICE:...... PHONE:... FAX:...

More information

Sonic Safety. Sonic Safety. Wireless Safety and Security System. HG-1500 System. For System Package OWNER S MANUAL

Sonic Safety. Sonic Safety. Wireless Safety and Security System. HG-1500 System. For System Package OWNER S MANUAL Sonic Safety Sonic Safety Wireless Safety and Security System HG-1500 System For System Package OWNER S MANUAL Table of Contents Introduction (HG-1500).. 3 System Package. 3 Optional Accessories.. 3 Deployment

More information

DESTINY OWNER S MANUAL

DESTINY OWNER S MANUAL DESTINY OWNER S MANUAL DESTINY You have made a wise decision to protect your family and property with the DESTINY Security System. The DESTINY has been designed to provide you with a maximum level of security

More information

SK642 THE TELEPHONE DIALER REQUIRES A LAND TELEPHONE LINE TO MAKE OUTGOING CALLS AND ELECTRICITY.

SK642 THE TELEPHONE DIALER REQUIRES A LAND TELEPHONE LINE TO MAKE OUTGOING CALLS AND ELECTRICITY. SK642 WIRELESS WATER ALARM SYSTEM WITH AUTO DIALER OWNER'S MANUAL AND SET UP INSTRUCTIONS. Thank you for choosing Ideal Security s Wireless Water Alarm with Telephone Dialer. Please read through complete

More information

Testing the System. Battery Test. Dialer Test. Fire Drill Test (Code + [#] + 69) One-Man Fire Walk-Test (Code + [#] + 68)

Testing the System. Battery Test. Dialer Test. Fire Drill Test (Code + [#] + 69) One-Man Fire Walk-Test (Code + [#] + 68) F A 1 7 0 0 c Testing the System Battery Test When AC power is present, the FA1700C runs a brief battery test every 60 seconds to determine if there is a battery connected, and runs an extended battery

More information

Using Your. Security System With LED Keypad S5030, S5031, S5032

Using Your. Security System With LED Keypad S5030, S5031, S5032 Using Your Security System With LED Keypad S5030, S5031, S5032 Contents 1 Overview Your Security System... 1 How Your Security System Works... 2 Your System's Programming... 3 Getting Used to Your System...

More information

MEDICAL ALERT SETUP GUIDE

MEDICAL ALERT SETUP GUIDE MEDICAL ALERT SETUP GUIDE GETTING STARTED STARTED You have made a great decision to protect yourself with Medical Alert! Be sure to wear your wrist button or neck button everyday to stay protected all

More information

Control/Communicator Installation Manual

Control/Communicator Installation Manual DAS NETWORX NX-12 Control/Communicator Installation Manual General Description...2 Ordering Information...2 Option Definitions...3 Programming the LED Code Pads...5 Programming the NX-12...9 Types of Programming

More information

Preface. Thank you for purchasing our GSM Security Alarm System ( The System )! The System will keep your home and property safe around the clock.

Preface. Thank you for purchasing our GSM Security Alarm System ( The System )! The System will keep your home and property safe around the clock. Preface Thank you for purchasing our GSM Security Alarm System ( The System )! The System will keep your home and property safe around the clock. The GSM Security Alarm ( The Alarm ) adopts the most advanced

More information

Thank you for choosing Ideal Security s Home Security System with Telephone Dialer.

Thank you for choosing Ideal Security s Home Security System with Telephone Dialer. SK618 WIRELESS ALARM SYSTEM WITH AUTO DIALER OWNER'S MANUAL Thank you for choosing Ideal Security s Home Security System with Telephone Dialer. If at any time during your installation you have any questions

More information

To activate using remote control: press [ ] key once. To activate using keyboard: on panel keyboard [ ] keys once.

To activate using remote control: press [ ] key once. To activate using keyboard: on panel keyboard [ ] keys once. Table of Content 1.1General Description----------------------------------------------------------------------2 2.2System Setup-----------------------------------------------------------------------------3

More information

CC880/LP880, SC8016. Operators Guide Solution-16, Solution-16 Safecom

CC880/LP880, SC8016. Operators Guide Solution-16, Solution-16 Safecom CC880/LP880, SC8016 EN Operators Guide Solution-16, Solution-16 Safecom CC880/LP880, SC8016 Operators Guide EN 2 Copyright Notice Unless otherwise indicated, this publication is the copyright of Bosch

More information

Wireless Keypads LKP(E)S8M Series

Wireless Keypads LKP(E)S8M Series Wireless Keypads LKP(E)S8M Series User manual Contents Congratulations on your purchase of this Honeywell wireless keypad. To make the best out of your equipment we advise you to read this manual carefully.

More information

DYGIZONE GJD910 Lighting Controller & Enunciator

DYGIZONE GJD910 Lighting Controller & Enunciator DYGIZONE GJD910 Lighting Controller & Enunciator MASTER WIRING IDENTIFICATION Power up to the DygiZone and you will see: All the LED s (red,yellow,green and blue buttons) will flash All the LCD icons will

More information

NESS 5000 SERIES DIALLER

NESS 5000 SERIES DIALLER NESS 5000 SERIES DIALLER INSTALLATION MANUAL This manual is designed to provide the installation instructions on the NESS SECURITY PRODUCT'S 5000 SERIES Dialler. For complete details on the warranty or

More information

Solution Ultima Series Operators Manual ISSUE 1.00

Solution Ultima Series Operators Manual ISSUE 1.00 Solution Ultima Series Operators Manual ISSUE 1.00 Solution Ultima Series Operators Manual Copyright 1998 by, SYDNEY, AUSTRALIA Document Part Number MA488O DOCUMENT ISSUE 1.00 Printed 16 February 1999

More information

MOBILE CALL GSM Alarm System User s Manual

MOBILE CALL GSM Alarm System User s Manual MOBILE CALL GSM Alarm System User s Manual Profile For a better understanding of this product, please read this user manual thoroughly before using it. Contents Function Introduction (3) Alarm Host Diagram

More information

ALARM SYSTEM USER S MANUAL Rev

ALARM SYSTEM USER S MANUAL Rev ALARM SYSTEM USER S MANUAL Rev.06 890-00011 Manufacturer: Viatron Electronics 3514 1st Street, St-Hubert (Quebec) Canada J3Y 8Y5 WARNINGS the warranty can be void if the Agri-Alert 2400 is used in a manner

More information

Interactive Technologies Inc North 2nd Street North St. Paul, MN Technical Manuals Online! -

Interactive Technologies Inc North 2nd Street North St. Paul, MN Technical Manuals Online! - Security System Owner s Manual Interactive Technologies Inc. 2266 North 2nd Street North St. Paul, MN 55109 FCC Notices FCC Part 15 Information to the User Changes or modifications not expressly approved

More information

Power Wave LCD Keypads. Users Operating and Programming Guide Version 2.00

Power Wave LCD Keypads. Users Operating and Programming Guide Version 2.00 Power Wave LCD Keypads CR-16S CR-16M Users Operating and Programming Guide Version 2.00 P/N 7102265 Rev. C N.A May 2003 Contents Introduction...4 Meet the PowerWave Alarm Control System... 4 Typical Alarm

More information

Simon XTi Quick Operation Guide

Simon XTi Quick Operation Guide Simon XTi Quick Operation Guide This is the Quick Operation Guide for the Simon XTi system (models 600-1054-95R-12 & 600-1054-95R-12-CN). The Simon XTi provides a graphical user interface for programming

More information

Thank you for choosing Ideal Security s Home Security System with Telephone Dialer.

Thank you for choosing Ideal Security s Home Security System with Telephone Dialer. SK618 WIRELESS ALARM SYSTEM WITH AUTO DIALER OWNER'S MANUAL Thank you for choosing Ideal Security s Home Security System with Telephone Dialer. If at any time during your installation you have any questions

More information

USER & INSTALLATION GUIDE

USER & INSTALLATION GUIDE Reach Plus At Home Alarm Unit Touch Personal Pendant USER & INSTALLATION GUIDE www.tynetec.co.uk SECTION 1 USER INSTRUCTIONS Section Topic Page 1.1 Important Information 3 1.2 Unpacking the Reach Plus

More information

XRSuper6. User s Guide

XRSuper6. User s Guide XRSuper6 User s Guide Silencing an Alarm All/Perimeter and Home/Away Systems While the alarm bell or siren is sounding, enter your user code. DISARM SILENCE. Select SILENCE to stop the bell or siren. This

More information

Alarm Control Panel WIC-16Z4P WIC-5Z2P. User Instructions

Alarm Control Panel WIC-16Z4P WIC-5Z2P. User Instructions WIC-16Z4P WIC-5Z2P User Instructions Page : 2/14 INDEX # Function Page 1 Add a New User Code 11 2 Arm or Disarm All Areas or Disarm Selected Areas (Partitioned System) 8 3 Arming the System (Away Mode)

More information

Solution Ultima 862 Operators Manual ISSUE 1.10

Solution Ultima 862 Operators Manual ISSUE 1.10 Solution Ultima 862 Operators Manual ISSUE 1.10 Solution Ultima 862 Operators Manual Copyright 2001 by, SYDNEY, AUSTRALIA Document Part Number MA486O DOCUMENT ISSUE 1.10 Printed 24 April 2001 This documentation

More information

Honeywell Control Panels FOR RESIDENTIAL AND COMMERCIAL INSTALLATIONS. Feature Charts

Honeywell Control Panels FOR RESIDENTIAL AND COMMERCIAL INSTALLATIONS. Feature Charts Honeywell Control Panels FOR RESIDENTIAL AND COMMERCIAL INSTALLATIONS Feature Charts Control Panels FEATURE CHART LYNX Plus (L3000) (Supported Feature) (Not Supported) N/A (Not Applicable) LYNX Touch (L5210)

More information

X64 Wireless Training

X64 Wireless Training X64 Wireless Training IDS Contents 1 Contents Features 3 Wireless Hardware 4 IDS & Duevi integration PCB 5 LED operation 5 Wireless Device Hardware setup 6 Location 260 7 LED Keypad Instructions 7 Adding

More information

status AW1 Plus WiFi Alarm System User Manual

status AW1 Plus WiFi Alarm System User Manual status AW1 Plus WiFi Alarm System User Manual Foreword Congratulations on your purchase of the AW1 Plus Alarm system. Before you commence installation we recommend that you unpack the product, familiarise

More information

MK9 series CarePhone. Installers Mauual

MK9 series CarePhone. Installers Mauual MK9 series CarePhone Installers Mauual 1 Please ensure that the last thing you do before leaving a User with an alarm is to make a test call through to the Monitoring Centre and speak to the Operator.

More information

Watchguard WGAP864 User Manual

Watchguard WGAP864 User Manual Watchguard WGAP864 User Manual v1.0 Issued September 2016 1 2 Table of Contents Glossary... 5 1. Introduction to your Watchguard WGAP864... 6 2. Before Operating your Alarm System... 6 3. Understanding

More information

Solution-6 Operators Manual Page 1 Preface Congratulations on selecting the Solution-6 security control system for your installation. So that you can obtain the most from your unit, we suggest that you

More information

HILLS Series LED Code Pad User Manual

HILLS Series LED Code Pad User Manual HILLS Series LED Code Pad User Manual Not all features may be available on your system Check with your installer to find out which features are programmed Page 2 TABLE OF CONTENTS Code Pad Diagrams...2

More information

AGRI-ALERT 9600 ALARM SYSTEM USER MANUAL

AGRI-ALERT 9600 ALARM SYSTEM USER MANUAL AGRI-ALERT 9600 ALARM SYSTEM USER MANUAL M 890-00279 rev. 14 K 895-00004 rev. 00 Manufacturer: Viatron Electronics 5200, Armand-Frappier St-Hubert (Quebec) Canada J3Z 1G5 WARNINGS The warranty can be void

More information

Total Connect Box. User manual

Total Connect Box. User manual Total Connect Box User manual 1 Congratulations on your purchase of the Honeywell Total Connect Box security system. To make the best out of your system we advise you to read this manual carefully. This

More information

Sidekick II Receiver Model # SK2-SS 418MHz

Sidekick II Receiver Model # SK2-SS 418MHz www.silentcall.com Sidekick II Receiver Model # SK2-SS 418MHz Signature Series Sidekick II Signature Series Model # SK2-SS (418 MHz Receiver) Setup and Operation: 1. Plug the power supply pin jack into

More information

OPERATING GUIDE FOR YOUR RP1054D KEYPAD

OPERATING GUIDE FOR YOUR RP1054D KEYPAD OPERATING GUIDE FOR YOUR RP1054D KEYPAD Napco 1992 DESIGN PATS. PENDING Technical Manuals Online! - http://www.tech-man.com CONGRATULATIONS!...on your purchase of a NAPCO Magnum Alert security system.

More information

Elderly Care Alarm System

Elderly Care Alarm System Introduction 24/7 Peace of mind for your family The GSM Elderly Care Alarm System is a new released smart solution for take care of senior, aged, elder or disabled people on their daily life. Big LED display

More information

Profile. For a better understanding of this product, please read this user manual thoroughly before using it.

Profile. For a better understanding of this product, please read this user manual thoroughly before using it. Intelligent GSM Auto-Dial Alarm System User s Manual Profile For a better understanding of this product, please read this user manual thoroughly before using it. Contents Function Introduction (3) Alarm

More information

D6500 reports are shown in typewriter style letters. For example, AC FAILED indicates the report sent when the panel reports an AC power failure.

D6500 reports are shown in typewriter style letters. For example, AC FAILED indicates the report sent when the panel reports an AC power failure. Notice The material and instructions covered in this manual have been carefully checked for accuracy and are presumed to be reliable. However, Radionics, Inc. assumes no responsibility for inaccuracies

More information

SA 2650 Kit User Manual

SA 2650 Kit User Manual SA 2650 Kit User Manual Table of Contents 1. System Installation Planning 1 2. Device Introduction 3 3. Getting Started 6 4. System Default Setting 10 5. Connect2Home Application 11 6. System Information

More information

USER GUIDE WIRE-FREE HOME PROTECTION SYSTEM AG100+ CONTENTS

USER GUIDE WIRE-FREE HOME PROTECTION SYSTEM AG100+ CONTENTS CONTENTS USER GUIDE WIRE-FREE HOME PROTECTION SYSTEM AG00 Section Getting started. General system overview. Introduction to the system. Items included with the system. Introduction to the Smart Panel.5

More information

1126 Series Ceiling Mount PIR Motion Detector

1126 Series Ceiling Mount PIR Motion Detector Installation Sheet 1126 Series Ceiling Mount PIR Motion Detector Description The 1126 Series PIR (Passive Infrared) Motion Detectors are a compact wireless PIR. The 1126 Series offer 360, Wide Angle, or

More information

MXD3G User Manual Revision 0 July 29, 2013

MXD3G User Manual Revision 0 July 29, 2013 MXD3G User Manual Revision 0 July 29, 2013 Manufactured by Mytrex, Inc. 10321 South Beckstead Lane South Jordan, UT 84095 (801) 571-4121, Fax (801) 571-4606 Toll Free (800) 688-9576, Fax (877) 571-4606

More information

status AW1 WiFi Alarm System Printed in China PA : AW1-UM-EN-V1.0 User Manual 2016 Chuango. All Rights Reserved.

status AW1 WiFi Alarm System Printed in China PA : AW1-UM-EN-V1.0 User Manual 2016 Chuango. All Rights Reserved. status 2016 Chuango. All Rights Reserved. Printed in China PA : AW1-UM-EN-V1.0 AW1 WiFi Alarm System User Manual Foreword Contents Congratulations on your purchase of the AW1 Alarm system. Before you commence

More information

User's Manual VISTA-40 N7003V1 6/97

User's Manual VISTA-40 N7003V1 6/97 S e c u r i t y S y s t e m User's Manual VISTA-40 N7003V1 6/97 SYSTEM OVERVIEW...3 General...3 A Partitioned System...3 Zones...3 Burglary Protection...4 Fire Protection...4 Alarms...5 Emergency (Panic)

More information

SMART HOME SECURITY. Dual Network Communicating Alarm System with RFID INVINCIBLE. Instruction Manual. Customer Helpline

SMART HOME SECURITY. Dual Network Communicating Alarm System with RFID INVINCIBLE. Instruction Manual. Customer Helpline SMART HOME SECURITY Dual Network Communicating Alarm System with RFID INVINCIBLE Instruction Manual Customer Helpline 045 57 500 Table of Contents Kit Contents ---------------------------------------------------------------------

More information

USER & INSTALLATION GUIDE

USER & INSTALLATION GUIDE Reach At Home Alarm Unit Touch Personal Pendant USER & INSTALLATION GUIDE www.tynetec.co.uk SECTION 1 USER INSTRUCTIONS Section Topic Page 1.1 Important Information 3 1.2 Unpacking the Reach At Home Alarm

More information

Quick Reference Guide

Quick Reference Guide infinite Prime with Hybrid Connections User Manual - Version 1.00 Catalog Number: ZI0473A (1/07) All data is subject to change without prior notice. Hereby, Electronics Line 3000 Ltd. declares that this

More information

Control Panel ICP-SOL2-P/ICP-SOL3-P. en User's Guide

Control Panel ICP-SOL2-P/ICP-SOL3-P. en User's Guide Control Panel ICP-SOL2-P/ICP-SOL3-P en User's Guide Control Panel Table of Contents en 3 Table of contents 1 Introduction 5 2 Specifications 6 3 Codepad Introduction 7 3.1 Codepad 7 3.2 Quick Codepad

More information

Careline Anna Careline GSM

Careline Anna Careline GSM Careline Anna / Careline GSM Programming and installation manual List of contents 1 Introduction... 3 1.1 General description of Careline Anna/GSM... 3 1.2 General description of Tx4 alarm transmitter...

More information

Control Panel ICP-SOL2-P/ICP-SOL3-P. en User's Guide

Control Panel ICP-SOL2-P/ICP-SOL3-P. en User's Guide Control Panel ICP-SOL2-P/ICP-SOL3-P en User's Guide Control Panel Table of Contents en 3 Table of contents 1 Introduction 5 2 Specifications 6 3 Codepad Introduction 7 3.1 Codepad 7 3.2 Quick Codepad

More information

ICP-CC408 ICP-CC408 EN. Control Panel. User s Guide

ICP-CC408 ICP-CC408 EN. Control Panel. User s Guide ICP-CC408 EN User s Guide ICP-CC408 Control Panel ICP-CC408 User's Guide Notices EN 2 Copyright Notice Unless otherwise indicated, this publication is the copyright of Bosch Security Systems, Inc, ( Bosch

More information

User s Manual. System Information... 3 Using the Touchpad Buttons... 3 General Operation... 4 Using Systems with Keyswitches... 4

User s Manual. System Information... 3 Using the Touchpad Buttons... 3 General Operation... 4 Using Systems with Keyswitches... 4 ITI Part No. 60-562-03 60-562-06 $GYHQWŒ&RPPHUFLDO )LUH6\VWHP Document Number: 466-1705 Rev. B November 2001 System Information... 3 Using the Touchpad Buttons... 3 General Operation... 4 Using Systems

More information

GSM Alarm System. User s Manual. Profile. MOBILE CALL GSM Alarm System

GSM Alarm System. User s Manual. Profile. MOBILE CALL GSM Alarm System MOBILE CALL GSM Alarm System GSM Alarm System System disarmed 11/26/2013 User s Manual Profile For a better understanding of this product, please read this user manual thoroughly before using it. CONTENTS

More information

3 User s settings. 3.3 Internal clock setting

3 User s settings. 3.3 Internal clock setting 2.9 Subsystem arming In a large building a sub control panel can be enrolled to the JA-63. The subsystem reports all alarms and failures to the main system. The installer can program if the systems will

More information

Table of Contents About This User s Guide... 2 Introduction... 2 Security System Basics... 3 What is a Point?... 3 What is a Faulted Point?...

Table of Contents About This User s Guide... 2 Introduction... 2 Security System Basics... 3 What is a Point?... 3 What is a Faulted Point?... Table of Contents About This User s Guide... 2 Introduction... 2 Security System Basics... 3 What is a Point?... 3 What is a Faulted Point?... 3 Are All Points the Same?... 3 Controlled Points... 4 24-Hour

More information

With Magictrl, you can control MatiGard anytime & anywhere via your smartphone, even without data network.

With Magictrl, you can control MatiGard anytime & anywhere via your smartphone, even without data network. MatiGard User Guide 02 Menu Feature-------------------------------------------------------------- 05 Overviews---------------------------------------------------------- 07 Read Before Using-----------------------------------------------

More information

Contents. Glossary Introduction to the IDS Notes Understanding the Keypad Indicators Operation of the Keypad...

Contents. Glossary Introduction to the IDS Notes Understanding the Keypad Indicators Operation of the Keypad... 2 Contents Glossary...7 1. Introduction to the IDS805...8 1.1 Notes...8 2. Understanding the Keypad Indicators...8 3. Operation of the Keypad...9 4. System Information...10 4.1 Programmed Functions...10

More information

MEDI-MINDER USER MANUAL

MEDI-MINDER USER MANUAL MEDI-MINDER USER MANUAL TABLE OF CONTENTS TABLE OF CONTENTS... 1 INTRODUCTION... 1 SMARTLINK FEATURES... 2 USING SMARTLINK... 3 SPECIAL FUNCTIONS... 5 DISPLAYS AND WARNINGS... 6 SPECIFICATIONS... 7 INTRODUCTION

More information

Digiplex System V2.14 / V2.2ACC. Control Panel Programming Guide

Digiplex System V2.14 / V2.2ACC. Control Panel Programming Guide Digiplex System V2.14 / V2.2ACC Control Panel Programming Guide Table of Contents Getting Started...2 What Do I Do First?...2 How Do I Program the Control Panel?...2 Single Digit Entry Method...2 Multiple

More information

WLS900 Wireless Security System. Table of Contents. Your installing company is, Name: Address: Phone: Your monitoring station is, Name: Phone:

WLS900 Wireless Security System. Table of Contents. Your installing company is, Name: Address: Phone: Your monitoring station is, Name: Phone: Table of Contents WLS900 Wireless Security System 1 Introduction 2 2 Using the Keypad 3 3 Arming the System 4 3A - Arming Levels; 4 3B - Arming the System in the Away Mode 4 3C - Improper Arming Warning

More information

Wolf Guard Touch Keypad GSM Wireless alarm system User s Manual

Wolf Guard Touch Keypad GSM Wireless alarm system User s Manual Wolf Guard Touch Keypad GSM Wireless alarm system User s Manual Page 1 Warning Do not remove the front or back cover of the unit and keep it intact. There are no parts inside this unit that can be repaired

More information

DIY Home Security Support 30 numbers wireless sensors

DIY Home Security Support 30 numbers wireless sensors 1. Package includes 1.1 Standard (1) One main unit (black, white) (2) One adapter (3) One remote controller (4) One wireless P.I.R motion detector (5) One telephone line 2. Outward introduction 2.1 Main

More information

All-In-One Wireless Security System V1.0. Model #: MG-6060

All-In-One Wireless Security System V1.0. Model #: MG-6060 All-In-One Wireless Security System V1.0 Model #: MG-6060 Reference and Installation Manual DRAFT Table of Contents Introduction... 5 About Magellan and this Manual... 5 Conventions... 5 Specifications...

More information

Fire Burglary Instruments Inc. XL-2G Gold Control/Communicator Installation Training Seminar Rev. 5/96

Fire Burglary Instruments Inc. XL-2G Gold Control/Communicator Installation Training Seminar Rev. 5/96 Fire Burglary Instruments Inc. XL-2G Gold Control/Communicator Installation Training Seminar Rev. 5/96 XL-2G Gold Product Overview 7 Zones (6 programmable + panic or keyswitch zone) Fast Loop Response

More information

LED Keypads D720 Series User s Guide

LED Keypads D720 Series User s Guide LED Keypads D720 Series User s Guide D720 D720W D720B Table of Contents Fire Safety 3 The D720/D720W/D720B Keypad 4 Security System Basics 5 Turning the System On and Off 7 Silencing and Reporting Alarms

More information

Programming the Vi+ using a Series Telephone. Tunstall Vi+

Programming the Vi+ using a Series Telephone. Tunstall Vi+ Tunstall Vi+ Programming the Vi+ using a SeriesTelephone Your Vi+ Page 2 Ver 1 4/24/2015 Programming a telecare sensor to the Vi+ Telecare sensors with plug and play functionality can be programmed to

More information

V1.0. Smart Home Alarm System. User Manual. APP download via QR Code scanning. Please read the manual carefully before using.

V1.0. Smart Home Alarm System. User Manual. APP download via QR Code scanning. Please read the manual carefully before using. V1.0 Smart Home Alarm System User Manual APP download via QR Code scanning Please read the manual carefully before using. Content FUNCTION PROFILE 2 THE SCHEMATIC GRAPH OF HOST 3 PROCESS OF BOOTING 6 OPERATION

More information