Alarm Systems Alarm Bot CS2004E CS CS CS H2Oil Alarm System...12
|
|
- Lizbeth Bell
- 5 years ago
- Views:
Transcription
1
2 TABLE OF CONTENTS Control Panels Page # Power Zone Jr. Simplex Float Panel...4 Power Zone Simplex Float Panel...4 Power Zone Duplex Float Panel...4 Fusion Economy...5 Fusion Simplex Float Panel...5 Fusion Duplex Float Panel...5 Fusion Special Options...6 RK Series Single Phase Simplex Float Panel...7 RK Series Three Phase Simplex Float Panel...7 RK Series Single Phase Duplex Float Panel...7 RK Series Three Phase Duplex Float Panel...7 RK Series Special Options...8 RK Series Display Option Overview...9 Minuteman Level Alert Pedestal...10 Alarm Systems Alarm Bot CS2004E CS CS CS H2Oil Alarm System...12 Control Floats Control Duty Narrow Angle Mechanical Control Switch...13 Control Duty Narrow Angle Low Current Mechanical Control Switch...13 Control Duty Narrow Angle Mercury Control Switch...13 Control Duty Narrow Angle Mini Mercury Control Switch...14 Control Duty Vertical Reed Switch...14 Pump Floats Medium Duty Wide Angle Mechanical Pump Switch...15 Heavy Duty Wide Angle Mechanical Pump Switch...15 Medium Duty Wide Angle Mercury Pump Switch...16 Medium Duty Wide Angle Mini Mercury Pump Switch...16 Medium Duty Limited Space Pump Switch...16 Medium Duty Wide Angle Dual Pump Switch...17 Accessories Float Accessories...18 Junction Boxes...18 Pedestals...18 Special Confi gurations...19
3 CONTROL PANELS POWER ZONE PANELS Single phase, simplex or duplex demand dose or timed dose fl oat controlled system for pump control and system monitoring. MODEL # F (2) 15 foot fl oat switches - one pump switch and one control switch $40 HO D MAX FLA ENCLOSURE TYPE POWER ZONE JR. SIMPLEX FLOAT PANELS ENCLOSURE MATERIAL Includes a 2 hub to mount enclosure on a 2 conduit & an outlet that allows for plug-in installation of pump. (115V - 15 amp max.) Dual Power - Separates incoming power to Pump & Alarm/Control INPUT POWER VAC - PH LIST PRICE PANEL ONLY PZJRF NEMA 4X Polycarbonate $ PZJRF NEMA 4X Polycarbonate $ Example with all options selected: PZJRF115-F-HO-D = $ List $10 115V - $10 230V - $25 MODEL # MAX FLA ENCLOSURE TYPE POWER ZONE SIMPLEX FLOAT PANELS INPUT POWER VAC - PH CIRCUIT BREAKERS LIST PRICE PANEL ONLY PZSF NEMA 4X None $ PZSF115CB 16 NEMA 4X Motor & Alarm $ PZSF115ACB 16 NEMA 4X Motor, Control & Alarm $ PZSF NEMA 4X None $ PZSF230CB 16 NEMA 4X Motor & Alarm $ PZSF230ACB 16 NEMA 4X Motor, Control & Alarm $ F (3) 20 foot mechanical control switches $75 X Auxiliary Alarm & Redundant Off $40 HD Heavy Duty - Increases breakers and wire gauge to allow FLA (N/A with 115V outlet) $20 PED Poly Pedestal with access door $96 TD Time Dosing Program $46 Example with Floats, Outlet, and Pedestal: PZSF115CB-F-PED-TD = $ List POWER ZONE DUPLEX FLOAT PANELS Example MODEL with fl # oats, outlet MAX & pedestal: ENCLOSURE PZSF115CB-F-O-PED-TD INPUT POWER = $ List CIRCUIT LIST PRICE FLA TYPE VAC - PH BREAKERS PANEL ONLY PZDF NEMA 4X None $ PZDF115CB 16 NEMA 4X Motor & Control $ PZDF115ACB 16 NEMA 4X Motor, Control & Alarm $ PZDF NEMA 4X None $ PZDF230CB 16 NEMA 4X Motor & Control $ PZDF230ACB 16 NEMA 4X Motor, Control & Alarm $ F (4) 20 foot mechanical control switches $100 X Auxiliary Alarm & Redundant Off $40 HD Heavy Duty - Increases breakers and wire gauge to allow FLA (N/A with 115V outlet) $30 PED Poly Pedestal with access door $96 Example with Floats and Pedestal: PZDF115CB-F-PED = $ List 4
4 CONTROL PANELS FUSION PANELS Single phase, simplex or duplex demand dose fl oat controlled system for pump control and system monitoring. MODEL # MAX FLA ENCLOSURE TYPE ECONOMY FUSION SIMPLEX FLOAT PANELS INPUT POWER VAC - PH CIRCUIT BREAKERS LIST PRICE PANEL ONLY EFS NEMA 4X None $ EFS115CB 12 NEMA 4X Motor & Control $ EFS115ACB 12 NEMA 4X Motor, Control & Alarm $ EFS NEMA 4X None $ EFS230CB 12 NEMA 4X Motor & Control $ EFS230ACB 12 NEMA 4X Motor, Control & Alarm $ F (3) 20 foot control switches $75 HD1 Heavy Duty 1: Increase breakers & wire gauge to allow FLA $20 HD2 Heavy Duty 2: Increase breakers & wire gauge to allow FLA $30 Example with Floats and Heavy Duty 2: EFS115CB-F-HD2 = $ List MODEL # MAX FLA ENCLOSURE TYPE FUSION SIMPLEX FLOAT PANELS INPUT POWER VAC - PH CIRCUIT BREAKERS LIST PRICE PANEL ONLY FS NEMA 4X None $ FS115CB 12 NEMA 4X Motor & Control $ FS115ACB 12 NEMA 4X Motor, Control & Alarm $ FS NEMA 4X None $ FS230CB 12 NEMA 4X Motor & Control $ FS230ACB 12 NEMA 4X Motor, Control & Alarm $ F (3) 20 foot control switches $75 HD1 Heavy Duty 1: Increase breakers & wire gauge to allow FLA $20 HD2 Heavy Duty 2: Increase breakers & wire gauge to allow FLA $30 Example with Floats: FS115CB-F = $ List MODEL # MAX FLA ENCLOSURE TYPE FUSION DUPLEX FLOAT PANELS INPUT POWER VAC - PH CIRCUIT BREAKERS LIST PRICE PANEL ONLY FD NEMA 4X None $ FD115CB 12 NEMA 4X Motor & Control $ FD115ACB 12 NEMA 4X Motor, Control & Alarm $ FD NEMA 4X None $ FD230CB 12 NEMA 4X Motor & Control $ FD230ACB 12 NEMA 4X Motor, Control & Alarm $ F (4) 20 foot control switches $100 HD1 Heavy Duty 1: Increase breakers & wire gauge to allow FLA $30 HD2 Heavy Duty 2: Increase breakers & wire gauge to allow FLA $40 Example with Heavy Duty 1: FD115ACB-HD1 = $ List 5
5 FUSION PANELS
6 CONTROL PANELS RK SERIES PANELS Single or three phase, simplex or duplex demand dose or timed dose fl oat controlled system for pump control and system monitoring. MODEL # MAX FLA ENCLOSURE TYPE Example with Floats and Time Dose DDC: RKSF115CB-F-DCTD = $ List RK SERIES SIMPLEX FLOAT PANELS INPUT POWER VAC - PH CIRCUIT BREAKERS LIST PRICE PANEL ONLY RKSF NEMA 4X None $ RKSF115CB 12 NEMA 4X Motor & Control $ RKSF115ACB 12 NEMA 4X Motor, Control & Alarm $ RKSF NEMA 4X None $ RKSF230CB 12 NEMA 4X Motor & Control $ RKSF230ACB 12 NEMA 4X Motor, Control & Alarm $ RKSF NEMA 4X 208/240/460-3 Motor $ F (3) 20 foot control switches $75 GR Grey Enclosure (black enclosure is standard) $0 X Auxiliary Alarm and Redundant Off $40 HD1 Heavy Duty 1: Increase breakers & wire gauge to allow FLA (3ph panels FLA) $20 HD2 Heavy Duty 2: Increase breakers & wire gauge to allow FLA $30 DC DCTD IB IBTD MODEL # Digital Display Center Time Dosing DDC Digital Interface Board Time Dosing DIB MAX FLA ENCLOSURE TYPE Example with Floats: RKDF115CB-F = $ List RK SERIES DUPLEX FLOAT PANELS INPUT POWER VAC - PH CIRCUIT BREAKERS $85 $127 $125 $205 LIST PRICE PANEL ONLY RKDF NEMA 4X None $ RKDF115CB 12 NEMA 4X Motor & Control $ RKDF115ACB 12 NEMA 4X Motor, Control & Alarm $ RKDF NEMA 4X None $ RKDF230CB 12 NEMA 4X Motor & Control $ RKDF230ACB 12 NEMA 4X Motor, Control & Alarm $ RKDF NEMA 4X 208/230/460-3 Motor $ F (4) 20 foot control switches $100 GR Grey Enclosure (black enclosure is standard) $0 X Auxiliary Alarm and Redundant Off $40 HD1 Heavy Duty 1: Increase breakers & wire gauge to allow FLA (3ph panels FLA) $30 HD2 Heavy Duty 2: Increase breakers & wire gauge to allow FLA $40 DC DCTD IB IBTD Digital Display Center Time Dosing DDC Digital Interface Board Time Dosing DIB $170 $250 $254 $399 7
7 RK SERIES PANELS Single or three phase, simplex or duplex demand dose or time dose fl oat controlled system for pump control and system monitoring. 3-PH Control Panels (208V / 230V / 460V / 575V)
8 CONTROL PANELS RK SERIES DISPLAYS The RK Series Displays are available factory installed or as an accessory that can be easily field installed. Installing either display is as simple as removing the factory installed removable face plate and inserting the new or upgraded display from the back side of the sub-door. Once installed, the displays enable viewing of panel information such as Elapsed Run Time Meters and Cycle Counters for each pump. Incorporating a Timed Dosing display transforms a basic level control panel into a programmable time dose panel. Timed dosing provides capabilities such as: Pump Run Time, Pump Off Time, Override Pump Run Time, Override Pump Off Time, and more (Time Dosing functionality varies between the DDC & DIB). The RK Series Displays are constantly being improved with new features. Please consult the factory or website periodically for the most up-todate available features The RK Series displays are currently available in two versions - the Digital Display Center (DDC), and the Digital Interface Board (DIB). The DDC display utilizes a (4) four character LED display screen while the DIB incorporates a two line, 16 character display screen providing a more complete read out for the user. DIGITAL DISPLAY CENTER (DDC) - 4 CHARACTER READ OUT MODEL# DESCRIPTION LIST PRICE FEATURES DDCS Simplex Elapsed Time Meter & Cycle Counter $ Character LED Display Simplex or Duplex Elapsed Time Meter(s) DDCSTD Simplex Timed Dosing w/time Meter & Counter $ Cycle Counters(s) Lead Pump Selector (Duplex Panels) DDCD Duplex Elapsed Time Meter & Cycle Counter $ DDCDTD Duplex Timed Dosing w/time Meter & Counter $ DIGITAL INTERFACE BOARD (DIB) - 32 CHARACTER READ OUT MODEL# DESCRIPTION LIST PRICE FEATURES DIBS Simplex Elapsed Time Meter & Cycle Counter $ Character LCD Display High Level Counter DIBD Duplex Elapsed Time Meter & Cycle Counter $ More Advanced Time Dosing On-Screen Alarm Annunciation Pump Failure Alarm (Duplex Panels) DIBSTD Simplex Time Dosing w/elapsed Time Meter & Cycle Counter $ Alarm History (last 3 alarms) Three Auxiliary 120V AC Inputs Lead Pump Selector (Duplex Panels) DIBDTD Duplex Time Dosing w/elapsed Time Meter & Cycle Counter $ ETMS - Cycle Counters Digital Display Center (DDC) Digital Interface Board (DIB) Typical RK Series Panel Illustraing Display Location on Sub-Door 9
9 CONTROL PANELS MINUTEMAN LEVEL ALERT PEDESTAL PANELS Pedestal mounted plugger control panel with high water alarm. Quick & Easy High Level Float Connection Piggy-back Wide Angle Pump Float (Optional) Pump Cord (Not Included) Quick & Easy Connection to Incoming Power with Wire Nuts 9V Battery Backup for High Level Alarm MINUTEMAN LEVEL ALERT PANELS PART # DESCRIPTION LIST PRICE PANEL ONLY CSMM Nema 4X Alarm with LED Alarm Light, outlet for piggyback float installation & 9V battery back-up. Includes a 15ft alarm fl oat switch and enclosure mounting feet. Piggyback pump switch & pedestal not included. $ CSMMP Nema 4X Pedestal Mounted Alarm with LED Alarm Light, outlet for piggyback fl oat installation & 9V battery back-up. Includes a 15ft alarm fl oat switch and rubber grommet to seal incoming wires. Piggyback pump switch not included. $ Volt $25 NF No Float included - Deducts Standard 15ft Alarm Float (-$25) (1) 15ft Piggyback pump switch 115V $50 GF 230V $58 T Terminal block incoming power connection $20 D Dual Power - Separate incoming power to Pump & Alarm/Control 115V $10 230V $20 Example Volt with a Piggyback fl oat: CSMMP-230-GF = $
10 ALARM SYSTEMS ALARM BOT PART # DESCRIPTION LIST PRICE NEMA 4X outdoor post alarm with 360º visual alert. Includes 20ft alarm fl oat and 20ft piggyback fl oat switch. $ NEMA 4X outdoor post alarm with 360º visual alert. Includes 20ft $ alarm fl oat switch NEMA 4X outdoor post alarm with 360º visual alert. No fl oat included $ CS2004E PART # DESCRIPTION LIST PRICE NEMA 4X outdoor alarm with alarm light and test-normal-silence toggle switch. Includes a 15ft fl oat switch and a 6 power cord with 3/8 seal-tight cord connectors. $ NF No Float Included - Deduct Standard 15ft alarm fl oat (-$30) H Example: CS2004E-H = $ List Exchanges the cord grips and power cord for a 2 hub adapter to mount over 2 electrical conduit. $0 CS2004 PART # DESCRIPTION LIST PRICE NEMA 4X outdoor alarm with LED alarm lights and touch to test/touch to silence circuitry. Includes a 15ft fl oat switch and a 6ft power cord with 3/8 seal-tight cord connectors. $ NF No Float Included - Deduct Standard 15ft alarm fl oat (-$30) H Exchanges the cord grips and power cord for a 2 hub adapter to mount over 2 electrical conduit. $0 X Provides one set of Aux. Alarm Contacts $45 Example: CS2004-H-X = $ List 11
11 ALARM SYSTEMS CS1200 PART # DESCRIPTION LIST PRICE NEMA 1 non-metallic indoor alarm with auto-reset battery backup feature. Includes a 15 foot fl oat switch and a 6ft power cord. $ AUX Auxiliary Alarm Contacts (CSA certifi ed only unit) $17.08 NF No Float Included - Deduct Standard 15ft alarm fl oat (-$30) Example: CS1200-AUX = $ List Note: Low level fl oat and longer fl oat lengths available. CS1000 PART # DESCRIPTION LIST PRICE NEMA 1 indoor alarm with manual reset feature. Includes a 15 foot fl oat switch and a 6ft power cord. $ NF No Float Included - Deduct Standard 15ft alarm float (-$30) SPKT Splice kit $6.64 Example: CS1000-SPKT = $ List Note: Low level fl oat and longer fl oat lengths available. H 2 OIL ALARM SYSTEM Provides pump control and alarm notification of potentially threatening water and oil levels in simplex pumping applications. PART # DESCRIPTION LIST PRICE H2Oil Alarm System $ H2Oil Alarm System with CS1200 Alarm $
12 CONTROL FLOATS FLOAT SWITCHES Due to the many variations of control fl oats, please consult your local Representative or the factory for our full offering of fl oats. CONTROL DUTY - NARROW ANGLE MECHANICAL CONTROL SWITCHES PART # DESCRIPTION PART # DESCRIPTION LIST PRICE SPECIFICATIONS CSPCNO CSPCNC $38.17 ELECTRICAL: CSWENO CSWENC $ VAC or 250 VAC 5 Amps CSPCNO CSPCNC $ CSWENO CSWENC $49.18 CONTROL DIFFERENTIAL: Approx. 1.5 in above or below CSPCNO CSPCNC $48.46 horizontal CSWENO CSWENC $ CSPCNO CSPCNC $ CSWENO CSWENC $73.52 CS = Control Switch PC = Pipe Clamp WE = Weighted Externally NO = Normally Open NC = Normally Closed NOTE: Descriptions are grouped by cable length measured in feet (15, 20, 30, 50). MOUNTING CLAMP is standard. If mounting clamp is not required, specify and deduct 60 from list price of PC model. PACKAGING: Bagged - Standard Boxed - Specify and add $1.80 to list price. Bulk - Specify and deduct 20 from list price. CONTROL DUTY - NARROW ANGLE LOW CURRENT MECHANICAL CONTROL SWITCHES PART # DESCRIPTION PART # DESCRIPTION LIST PRICE SPECIFICATIONS CSLCPCNO CSLCPCNC $42.00 ELECTRICAL: 125 VAC & 30 VDC CSLCWENO CSLCWENC $49.16 Maximum Electrical Load: 0.1 Amps CSLCPCNO CSLCPCNC $45.00 Minimum Electrical Load: ma CSLCWENO CSLCWENC $ VDC Minimum Electrical Load: 1 ma CSLCPCNO CSLCPCNC $51.50 CONTROL DIFFERENTIAL: CSLCWENO CSLCWENC $58.67 Approx. 1.5 in above or below horizontal CSLCPCNO CSLCPCNC $ CSLCWENO CSLCWENC $75.98 CS = Control Switch LC = Low Current PC = Pipe Clamp WE = Weighted Externally NO = Normally Open NC = Normally Closed NOTE: Descriptions are grouped by cable length measured in feet (15, 20, 30, 50). MOUNTING CLAMP is standard. If mounting clamp is not required, specify and deduct 60 from list price of PC model. PACKAGING: Bagged - Standard Boxed - Specify and add $1.80 to list price. Bulk - Specify and deduct 20 from list price. CONTROL DUTY - NARROW ANGLE MERCURY CONTROL SWITCHES PART # DESCRIPTION LIST PRICE SPECIFICATIONS CSVPCNO $45.03 ELECTRICAL: CSVPCNC $ VAC or 230 VAC 5 Amps CSVPCNO $ CSVPCNC $48.48 CONTROL DIFFERENTIAL: Approx. 5 in above or below CSVPCNO $55.96 horizontal CSVPCNC $ CSVPCNO $ CSVPCNO $73.44 CS = Control Switch V = Mercury PC = Pipe Clamp WE = Weighted Externally NO = Normally Open NC = Normally Closed MOUNTING CLAMP is standard. If mounting clamp is not required, specify and deduct 60 from list price of PC model. PACKAGING: Bagged - Standard Boxed - Specify and add $1.80 to list price. Bulk - Specify and deduct 20 from list price. 13
13 CONTROL FLOATS CONTROL DUTY - NARROW ANGLE MINI MERCURY CONTROL SWITCHES PART # DESCRIPTION LIST PRICE SPECIFICATIONS CSMVNO $38.04 ELECTRICAL: CSMVNC $ VAC or 230 VAC 5 Amps CSMVNO $ CSMVNC $41.64 CONTROL DIFFERENTIAL: Approx. 5 in above or below CSMVNO $45.19 horizontal CSMVNC $ CSMVNO $ CSMVNC $52.81 CS = Control Switch MV = Mini Mercury NO = Normally Open NC = Normally Closed MOUNTING CLAMP is standard. If mounting clamp is not required, specify and deduct 60 from list price of PC model. PACKAGING: Bagged - Standard Boxed - Specify and add $1.80 to list price. Bulk - Specify and deduct 20 from list price. CONTROL DUTY - VERTICAL REED SWITCH PART # DESCRIPTION LIST PRICE SPECIFICATIONS P 15CSRS1 $84.69 ELECTRICAL: 250mA, VAC, 50/60 Hz CS = Control Switch RS = Reed Switch 1 = 120VAC 500mA, 6-12 VDC, 50/60 Hz MAXIMUM ANGLE FROM VERTICAL: 5º CONTROL DIFFERENTIAL: Approx..375 inch 14
14 PUMP FLOATS FLOAT SWITCHES Due to the many variations of pump fl oats, please consult your local Representative or the factory for our full offering of fl oats. MEDIUM DUTY - WIDE ANGLE MECHANICAL PUMP SWITCHES PART # DESCRIPTION PART # DESCRIPTION LIST PRICE SPECIFICATIONS PSD1WP PSU1WP $62.81 ELECTRICAL: 125 VAC or 250 VAC PSDWOP PSUWOP $55.48 MAXIMUM PUMP RUN PSD1WP PSU1WP $ PSDWOP PSUWOP $ Amps PSD1WP PSU1WP $73.10 MAXIMUM PUMP START PSDWOP PSUWOP $ Amps PSD1WP PSU1WP $90.41 PUMPING RANGE: PSDWOP PSUWOP $ inches PS = Pump Switch D = Pump Down U = Pump Up 1 = 125VAC 2 = 250VAC WP = With Plug WOP = With Out Plug NOTE: Descriptions are grouped by cable length measured in feet (15, 20, 30, 50). MOUNTING CLAMP is standard. If mounting clamp is not required, specify and deduct 60 from list price. CABLE WEIGHT MOUNTING is also available. PACKAGING: Boxed - Standard Bagged - Specify and deduct 40 from list price. Bulk - Specify and deduct 60 from list price. HEAVY DUTY - WIDE ANGLE MECHANICAL PUMP SWITCHES PART # DESCRIPTION PART # DESCRIPTION LIST PRICE SPECIFICATIONS PSPD1WP PSPU1WP $85.51 ELECTRICAL: PSPD2WP PSPU2WP $ VAC or 230 VAC PSPDWOP PSPUWOP $78.56 MAXIMUM PUMP RUN PSPD1WP PSPU1WP $ Amps PSPD2WP PSPU2WP $ PSPDWOP PSPUWOP $82.12 MAXIMUM PUMP START PSPD1WP PSPU1WP $ Amps PSPD2WP PSPU2WP $99.47 RECOMMENDED PUMP HP: PSPDWOP PSPUWOP $ V - 3/4 HP or less 230V - 2HP or less PSPD1WP PSPU1WP $ PSPD2WP PSPU2WP $ PUMPING RANGE: 7-36 inches PSPDWOP PSPUWOP $ PS = Pump Switch D = Pump Down U = Pump Up 1 = 120VAC 2 = 230VAC WP = With Plug WOP = With Out Plug NOTE: Descriptions are grouped by cable length measured in feet (15, 20, 30, 50). MOUNTING CLAMP is standard. If mounting clamp is not required, specify and deduct 60 from list price. CABLE WEIGHT MOUNTING is also available. PACKAGING: Boxed - Standard Bagged - Specify and deduct 40 from list price. Bulk - Specify and deduct 60 from list price. 15
15 PUMP FLOATS MEDIUM DUTY - WIDE ANGLE MERCURY PUMP SWITCHES PART # DESCRIPTION PART # DESCRIPTION LIST PRICE SPECIFICATIONS PSVD1WP PSVU1WP $ ELECTRICAL: 1 HP, 120 VAC PSVD2WP PSVU2WP $ HP, 230 VAC PSVDWOP PSVUWOP $ PSVD1WP PSVU1WP $ PSVD2WP PSVU2WP $ PSVDWOP PSVUWOP $ PSVD1WP PSVU1WP $ PSVD2WP PSVU2WP $ PSVDWOP PSVUWOP $ MAXIMUM PUMP RUN 15 Amps - 120V 12 Amps - 230V MAXIMUM PUMP START 55 Amps - 120V 35 Amps - 230V PUMPING RANGE: inches PS = Pump Switch V = Mercury D = Pump Down U = Pump Up 1 = 120VAC 2 = 230VAC WP = With Plug WOP = With Out Plug NOTE: Descriptions are grouped by cable length measured in feet (15, 20, 30). MOUNTING CLAMP is standard. If mounting clamp is not required, specify and deduct 60 from list price. PACKAGING: Boxed - Standard Bagged - Specify and deduct 40 from list price. Bulk - Specify and deduct 60 from list price. MEDIUM DUTY - WIDE ANGLE MINI MERCURY PUMP SWITCHES PART # DESCRIPTION PART # DESCRIPTION LIST PRICE SPECIFICATIONS PSJVD1WP PSJVU1WP $69.68 ELECTRICAL: 1/2 HP, 120 VAC PSJVD2WP PSJVU2WP $ HP, 230 VAC PSJVDWOP PSJVUWOP $ PSJVD1WP PSJVU1WP $ PSJVD2WP PSJVU2WP $ PSJVDWOP PSJVUWOP $ PSJVD1WP PSJVU1WP $ PSJVD2WP PSJVU2WP $ PSJVDWOP PSJVUWOP $72.98 MAXIMUM PUMP RUN 13 Amps - 120V 8 Amps - 230V MAXIMUM PUMP START 40 Amps - 120V 20 Amps - 230V PUMPING RANGE: inches PS = Pump Switch JV = Junior Mercury D = Pump Down U = Pump Up 1 = 120VAC 2 = 230VAC WP = With Plug WOP = With Out Plug NOTE: Descriptions are grouped by cable length measured in feet (15, 20, 30). MOUNTING CLAMP is standard. If mounting clamp is not required, specify and deduct 60 from list price. PACKAGING: Boxed - Standard Bagged - Specify and deduct 40 from list price. Bulk - Specify and deduct 60 from list price. MEDIUM DUTY - LIMITED SPACE PUMP SWITCH PART # DESCRIPTION LIST PRICE SPECIFICATIONS P 15PSLSD1WP $66.59 ELECTRICAL: P 20PSLSD1WP $ /2 HP, 120 VAC PS = Pump Switch LS = Limited Space D = Pump Down 1 = 120VAC WP = With Plug MOUNTING BRACKET and HOSE CLAMP are standard. PACKAGING: Boxed - Standard MAXIMUM PUMP RUN 13 Amps - 120V MAXIMUM PUMP START 60 Amps - 120V PUMPING RANGE: inches 16
16 PUMP FLOATS MEDIUM DUTY - WIDE ANGLE DUAL PUMP SWITCHES PART # DESCRIPTION PART # DESCRIPTION LIST PRICE SPECIFICATIONS PSDFD1WP PSDFU1WP $ ELECTRICAL: 15 FLA, 90 LRA PSDFD2WP PSDFU2WP $ or 240V PSDFD1WOP PSDFU1WOP $ PSDFD2WOP PSDFU2WOP $ PSDFD1WP PSDFU1WP $ PSDFD2WP PSDFU2WP $ PSDFD1WOP PSDFU1WOP $ PSDFD2WOP PSDFU2WOP $ PSDFD1WP PSDFU1WP $ MAXIMUM PUMP RUN 15 Amps - 120V 15 Amps - 240V MAXIMUM PUMP START 90 Amps - 120V 90 Amps - 240V PUMPING RANGE: 3-48 inches PSDFD2WP PSDFU2WP $ PSDFD1WOP PSDFU1WOP $ PSDFD2WOP PSDFU2WOP $ PS = Pump Switch DF = Dual Float D = Pump Down U = Pump Up 1 = 120VAC 2 = 230VAC WP = With Plug WOP = With Out Plug NOTE: Descriptions are grouped by cable length measured in feet (15, 20, 30). MOUNTING CLAMP is standard. If mounting clamp is not required, specify and deduct 60 from list price. PACKAGING: Boxed - Standard Bagged - Specify and deduct 40 from list price. Bulk - Specify and deduct 60 from list price. 17
17 ACCESSORIES FLOAT ACCESSORES PART # DESCRIPTION LIST PRICE P Pipe Mount stainless clamp for tethering fl oats $ Iron Weight Assembly $ P Cable Weight Assembly $ Stainless Steel Float Bracket with 3 black cord snubbers $ Stainless Steel fl oat Bracket with 4 black cord snubbers $ P P JUNCTION BOXES CSI offers a variety of junction boxes. Please consult the factory for box sizes, confi gurations and pricing. PEDESTALS PART # DESCRIPTION LIST PRICE Poly Pedestal for use with 10 X 8 enclosures $
18 SPECIAL CONFIGURATIONS CSI Controls specializes in designing and fabricating control systems for a wide variety of water and wastewater applications. Many of our standard products are available in special confi gurations. (Longer lead times may apply.) Common Available Configurations include: Panels requiring start components Generator receptacles Heat sensor and seal failure indication Auto Dialers UL Listed Panel Shop UL 508A Listing for industrial control panels In addition to design and confi guration, our engineers provide full documentation (CAD schematics), technical support and fi eld start-up assistance (when requested). With CSI in control, you can be confi dent your project is handled by experienced professionals every step of the way.
PRODUCT PRICE BOOK Pricing Effective February 4, We ve Got Panels Under Control.
PRODUCT PRICE BOOK Pricing Effective February 4, 2019 We ve Got Panels Under Control www.csicontrols.com ORDERING INFORMATION About this Price Booklet... This Suggested List Price Booklet is a consolidation
More informationWe ve Got Panels Under Control.
We ve Got Panels Under Control Table of Contents CONTROL PANELS Page # RK Series Single Phase Simplex... A.1 RK Series Single Phase Duplex... A.3 RK Series Three Phase Simplex... A.5 RK Series Three Phase
More informationQUICK SHIP Products. Available for Same/Next Day Shipment at NO ADDITIONAL CHARGE!
QUICK SHIP Products Available for Same/Next Day Shipment at NO ADDITIONAL CHARGE! www.sjerhombus.com NEED PRODUCTS IN A HURRY? DON T WORRY! SJE-Rhombus is committed to being the best in the industry. In
More informationPRODUCT PRICE BOOK January 1, 2019
PRODUCT PRICE BOOK January 1, 2019 Control Panels Alarm Systems Float Switches Accessories Follow us on: www.sjerhombus.com ORDERING INFORMATION To assist us in delivering the exact product you want, please
More informationPRODUCT PRICE BOOK September 4, 2018
PRODUCT PRICE BOOK September 4, 2018 Control Panels Alarm Systems Float Switches Accessories Follow us on: www.sjerhombus.com ORDERING INFORMATION To assist us in delivering the exact product you want,
More informationTHE MOST COMPLETE LINE OF SYSTEM ALARMS FLOAT SWITCHES ON-SITE ACCESSORIES CONTROL PANELS 24 HOUR SHIPPING ON ALL CATALOG ORDERS!
THE MOST COMPLETE LINE OF SYSTEM ALARMS FLOAT SWITCHES ON-SITE ACCESSORIES CONTROL PANELS 24 HOUR ON ALL CATALOG ORDERS! TABLE OF CONTENTS SYSTEM MONITORING DEVICES Plug-In Pedestal Alarm System... 4 High
More informationPRODUCT PRICE BOOK JUNE 4, 2018
PRODUCT PRICE BOOK JUNE 4, 2018 Control Panels Alarm Systems Float Switches Accessories Follow us on: www.sjerhombus.com ORDERING INFORMATION To assist us in delivering the exact product you want, please
More informationproduct brochure Sump, Effluent and Sewage Controls
product brochure Sump, Effluent and Sewage Controls Control Panels, Alarms and Float Switches From the Controls Leader You Trust www.sjerhombus.com EZ Series This line of innovative, affordable control
More information2 SJE-Rhombus...The Name You Trust Above: Simplex - Below: Duplex Above: Simplex - Below: Duplex
EZ Series Control Panels This line of innovative, affordable control panels is designed to make on-site installations easier. EZ Series control panels combine circuit board technology and easy operation
More informationSerious Products for Serious Contractors! User s Manual
Serious Products for Serious Contractors! User s Manual Pressure Systems Table of Contents About RK Series Pressure Systems...p 3 Pressure System Installation Instructions...p 4-8 Additional Parts the
More information2018 PRICING. alderonind.com STANDARD PRODUCTS
2018 PRICING alderonind.com STANDARD PRODUCTS Terms & Conditions PURCHASE ORDERS Preferred via email: orders@alderonind.com If e-mail is not available, send via fax: 218.483.3036 SHIPPING INFORMATION MINIMUMS:
More informationPiggyback Mechanical Float Switch. Piggyback Vertical Mechanical Float Switch. Piggyback Diaphragm Switch. Accessories
Piggyback Mechanical Float Switch Piggyback Vertical Mechanical Float Switch Residential sewage waste transfer RFSN-6, RFSN-9 and RFSN-10 any manual pump, up through 3/4 convert any manual pump, up hp
More informationCustom Pump Controls. The Custom Controls Solution Provider. A New Generation. Complete Management. Page 2
The Custom Controls Solution Provider Hydromatic has a reputation for providing dependable submersible pumps for wastewater lift stations and has continually raised the bar for quality products and customer
More informationPO Box 827 Hawley, MN (218) Fax (218)
Introduction Before proceeding with the installation or operation of the Oil Alert System, read all instructions thoroughly, as well as complying with all Federal, State and Local codes, Regulations and
More informationGRUNDFOS SEWAGE & EFFLUENT PUMP ACCESSORIES
GRUNDFOS SEWAGE & EFFLUENT PUMP ACCESSORIES GRUNDFOS CONTROL PANELS Simplex Panel Duplex Panel Standard Features LISTING: Underwriters Laboratories, UL 508. RATINGS: Model S1 rated up to 120 VAC, 1 Hp,
More informationCheck It Panel. 1 Phase Simplex Demand Dose Operation, Maintenance & Installation Manual. Introduction. Safety Guidelines
Introduction Before proceeding with the installation or operation of the control panel read all instructions thoroughly, as well as comply with all Federal, State and Local Codes, Regulations and Practices.
More informationPUMP / CONTROL PANEL SWITCHES TECHNICAL BROCHURE BCPFS R10
PUMP / CONTROL PANEL SWITCHES TECHNICAL BROCHURE BCPFS R10 TERMS TO KNOW Pump Switches are used to directly control the operation of a pump. They are normally wide-angle switches which means they operate
More informationInstaller Friendly Series In-Site. Installation Instructions and Operation/Troubleshooting Manual. Installation. Mounting the Control Panel
Installer Friendly Series In-Site SJE-Rhombus Type IFI Installation Instructions and Operation/Troubleshooting Manual This control panel must be installed and serviced by a licensed electrician in accordance
More informationTECHNICAL BROCHURE BCALARM R4. Indoor and Outdoor Panels and Accessories
TECHNICAL BROCHURE BCALARM R4 Indoor and Outdoor Panels and Accessories FEATURES Indoor and Outdoor alarm panels for sump, effluent and wastewater systems as well as test panel for troubleshooting. Use
More informationLiquid Level Alarms & Controls
16/06/17 E14 Low Voltage High Water Alarm Protects your home from potential water flood damage by placing anywhere a water leak may exist Loud 85 db buzzer sounds for up to 18 hours Intermittent chirp
More information631RF Amp Power Supply
631RF - 1.5 Amp Power Supply Modular Access Control Power Supply Field Selectable 12VDC or 24VDC Output - Standard Dual 12VDC and 24VDC Output - Optional Quality, Performance and Versatility The SDC 631RF
More informationCentro-Matic Automated Lubrication Systems System Controls
Selecting the right controls for your automated lubrication system is one of the last steps in the design process. Several different models may be chosen to control power-operated pumps, depending on the
More information1. Read all instructions before proceeding with the installation. Improper installation may void warranties.
Panel Installation efore Installing Panel 1. ead all instructions before proceeding with the installation. Improper installation may void warranties. 2. Inspect your order for completeness and inspect
More informationPS6 SERIES. Installation PS6 SERIES. Power Supplies c/w Fire Panel Interface, EOL Trigger and Standby Power Option
Installation PS6 SERIES Power Supplies PS6 SERIES Power Supplies c/w Fire Panel Interface, EOL Trigger and Standby Power Option Installation and Specifications Manual ISDPS6_SERIES 08121590 PCN15016 R05/15GR
More informationSJE-Rhombus Type IFS w/c-level Sensor Installation Instructions and Operation/Troubleshooting Manual
Installer Friendly Series SJE-Rhombus Type IFS w/c-level Sensor Installation Instructions and Operation/Troubleshooting Manual This control panel must be installed and serviced by a licensed electrician
More informationElectric Pumps. Introduction. W4100, W4200 & W4300 Condensate Pumps. Typical Condensate Pump Features
Electric Pumps Introduction W4100, W4200 & W4300 Condensate Pumps Watson McDaniel s Condensate Return and Boiler Feed Pumps are equipped with Cast Iron bodies and Bronze Impellers. The pump receiver tanks
More informationEngineered Basins Affordable, effective pressure sewer system Rocky, hilly, wet and flat topography Dependable, reliable and cost effective
brands you trust. Engineered Basins Affordable, effective pressure sewer system Rocky, hilly, wet and flat topography Dependable, reliable and cost effective ENGINEERED BASIN SERIES Barnes Pressure Sewer
More informationANCHOR BOLT DETAIL. Non-Shrink Grout. Poured In Place, After Equipment Setting. "L" Type Anchor Bolt Carbon Steel AISI 304 S.S.
ANCHOR BOLT DETAIL Heavy Flat Washer Heavy Hex Nut UNC Th'd Mounting Flange Of Equipment To Be Mounted C B A D Non-Shrink Grout. Poured In Place, After Equipment Setting. Heavy Flat Washer Heavy Hex Nut
More informationSingle Phase Simplex SXL21=3, SXL24=3, SXH21=3, and SXH24=3
Single Phase Simplex SXL21=3, SXL24=3, SXH21=3, and SXH24=3 Manufactured by SJE-Rhombus Installation Instructions and Operation/Troubleshooting Manual 7000 Apple Tree Avenue Bergen, New York 14416 Phone:
More informationVariable Frequency Drive SERIES MP800 VFD
Metron Fire Pump Controls and Accessories Variable Frequency Drive SERIES MP800 VFD Metron Fire Pump Controllers conform to the latest requirements of National Fire Protection Association s Standard for
More informationLaboratory Enclosed Scroll Air Compressor System with Premium NFPA Controls
Laboratory Enclosed Scroll Air Compressor System with Premium NFPA Controls Specification General The Powerex Laboratory Scroll Enclosed Air Compressor System is designed to provide clean, dry air for
More informationSIMPLEX WEATHERPROOF CONTROL PANELS
TECHNICAL BROCHURE BCP3 R10 FEATURES Rugged, NEMA 4X construction withstands even the most severe weather con ditions and prevents corrosion. Solid-state control board displays float status for ease of
More informationIon Genesis II Pump Controller Digital Level Control with Pump Alternation and High Water Alarm
Page 1 of 8 General Overview Thank you for purchasing an Ion Genesis controller. Take the time to read the instructions carefully before using this appliance. We strongly recommend that you keep this instruction
More informationBarnes Oil Sensor Switch
Elevator sump basins Transformer vaults Leachate wells Garages Barnes BOSS Barnes Oil Sensor Switch Model BOSS BOSS PLUS RPM 3450 3450 Oil Water Switch Cord Length 10 10 Enclosure Rated Options Automatic
More informationDual Technology Wall Switch Occupancy Sensor. Manual & Specification
Dual Technology Wall Switch Occupancy Sensor Manual & Specification PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH LOCAL ELECTRICAL CODES Douglas Lighting Controls Page 1 November 19, 2014 1. INTRODUCTION
More informationR E C T I F I E R I N V E R T E R C O N V E R T E R SB7
SCR Battery Charger Product Specifications Description The is RIC Electronics premiere SCR battery charger/rectifier. The provides power to critical DC loads through a wide range of outputs and is engineered
More informationMission Critical. Fuel Supply Systems
Fuel Supply Systems Insight Onsite Fuel Supply Systems Page 2 Simplex Mission Critical Fuel Supply Systems are comprehensive, integrated, project-matched fuel management systems for diesel and turbine
More informationPlumbing Supply Products
Plumbing Supply Products motralec rue Lavoisier. ZA Lavoisier. 93 HERBLAY CEDEX Tel. : 01.39.97.. / Fax. : 01.39.97.. Demande de prix / e-mail : service-commercial@motralec.com www.motralec.com Sump Pumps
More informationSpecification/ Data Sheet
Specification/ Data Sheet TRITON RP Agent Release Control Panel FEATURES Agent Release Control Panel designed specifically for suppression release operation with: Four initiating device circuits (IDCs)
More informationProfessional Plumbing brands you trust.
Professional Plumbing brands you trust. PLUMBING SUPPLY PRODUCTS Plumbing Supply Products Sump Pumps Submersible pumps for general purpose residential, commercial and light industrial sump applications.
More informationAcross-the-Line SERIES MP300 Combined Manual and Automatic
Across-the-Line SERIES MP300 Combined Manual and Automatic Metron Fire Pump Controllers conform to the latest requirements of National Fire Protection Association s Standard for Centrifugal Fire Pumps
More informationExcel-EN Conventional Fire Control Panel
Available as 2, 4, 6, 8,10 or 12 zones Approved to EN54-2 & 4 Modular expansion zone cards Programmable relays and outputs Optional additional sounder circuits Optional additional programmable outputs
More informationELECTRICAL DH VERSUS DR SERIES OPTIONS LISTED IN THE ONLINE AND PRINT CATALOG FOR ENVIRONMENT ONE DH071/DR071 STATIONS. WHICH DO YOU SELECT?
ELECTRICAL DH VERSUS DR SERIES OPTIONS LISTED IN THE ONLINE AND PRINT CATALOG FOR ENVIRONMENT ONE DH071/DR071 STATIONS. WHICH DO YOU SELECT? The DH071 is the hardwired or wired model where a cable connects
More informationgood things in small packages
FireShield Control Panels good things in small packages life safety for small buildings and shops A perfect arrangement FireShield offers the very best conventional fire alarm technology available, with
More informationEG Controls. SLIMVIEW 120 VOLT FLOAT SERIES DUPLEX PUMP CONTROL PANEL SPECIFICATION for CITY OF E G
E SLIMVIEW 120 VOLT FLOAT SERIES DUPLEX PUMP CONTROL PANEL SPECIFICATION for CITY OF DATE: 11/13/06 2/1/07 1 Copyright, E, Inc. E 1. ENERAL...4 1.1 Scope Of Work... 4 1.2 Codes and Standards... 4 2. PRODUCTS...5
More informationInstallation Guide for AL800UL-ADA. NAC Power Extender. Rev
Installation Guide for AL800UL-ADA NAC Power Extender Rev. 090500 Overview: The Altronix AL800UL-ADA is an extremely cost effective 8 amps voltage regulated remote power supply /battery charger. The AL800UL-ADA
More informationUnilift KP, AP, SU/SV, SE & EF
GRUNDFOS PRODUCT GUIDE Unilift KP, AP, SU/SV, SE & EF Sump, Sewage, Effluent and Utility Pumps 60 Hz LSEPG001 7-05 new.indd 1 9/27/2005, 9:36:00 AM Contents Mission General data 5 Performance range 5 Product
More informationRDM LOCK G Series Electromagnetic Lock. Listings. Standard Features. Ordering Information:
RDM LOCK G-1 1400 Series Electromagnetic Lock The patented 1400 Series Electromagnetic Lock is universal for all types of applications, including outdoor use. The innovative design will reduce installation
More informationFireSystem 2000 Commercial and Light Industrial Fire Alarm Control Panel
PROTECTOWIRE FireSystems Features Easily expandable Two supervised audible circuits Lamp and system trouble circuit test Ground fault detection Initiating device circuit (IDC) alarm test Monitors up to
More informationRefrigerators. Upright Blood Bank. i.series Horizon Series
Refrigerators Upright Blood Bank Blood Bank Refrigerators Helmer has provided high-quality laboratory equipment and refrigerated products for over 30 years. Our experience and attention to detail allow
More informationTECHNICAL BROCHURE BCPSDWWP R2 SIMPLEX/DUPLEX WASTEWATER DISCONNECT STYLE PANELS
TECHNICAL BROCHURE BCPSDWWP R SIMPLEX/DUPLEX WASTEWATER ONNECT STYLE PANELS PANEL FEATURES Oversize enclosure to accommodate all options. One main disconnect through-the-door with door interlock, prevents
More informationModel A2100 Series Annunciator
Seekirk Model A2100 Series Annunciator Applications: For usage within transformers, switchgear, breakers and/or within any processing equipment or control room applications either attended or unattended
More informationPower Supplies. Overview
Power Supplies Overview Access control provides enhanced security, audit trails, and custom credentials. The power supply is necessary to make the entire system operational. Power supplies offer accurate
More informationRack Mount Series Installation Guide
Rack Mount Series Installation Guide Models Include: Maximal1RHV Maximal1RV - 12VDC @ 4 amp or 24VDC @ 3 amp. - 12VDC @ 4 amp or 24VDC @ 3 amp. - Eight (8) Fuse Protected Outputs. - Sixteen (16) Fuse Protected
More informationAPS-300 SERIES DUAL VOLTAGE UL 294 LISTED ACCESS CONTROL POWER SUPPLIES
APS-300 SERIES DUAL VOLTAGE UL 294 LISTED ACCESS CONTROL POWER SUPPLIES POWER SUPPLY AND BATTERY CHARGER AC AND DC STATUS INDICATORS ENOUGH POWER TO SUPPORT UP TO 3 MAGLOCKS OR ELECTRIC STRIKES PLUS REQUIRED
More informationDIESEL Engine Fire Pump Controllers Features. FD120 Diesel Engine Controllers
DIESEL Engine Fire Pump Controllers Features FD120 Diesel Engine Controllers 1-1 March 2013 Diesel Product Description The DIESEL Plus Fire Pump Controllers from Eaton Corporation are designed to control
More informationMASTER JOCKEY PUMP CONTROLLER. Model JPCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc
MASTER JOCKEY PUMP CONTROLLER Model JPCE INSTRUCTION MANUAL C 2018 Master Control Systems, Inc TABLE OF CONTENTS Important Safety Information. Page 3 General Description and Installation.. Page 4 Model
More informationSoft Start Series MP700 Solid State, Reduced Voltage
Metron Fire Pump Controls and Accessories Soft Start Series MP700 Solid State, Reduced Voltage Metron Fire Pump Controllers conform to the latest requirements of National Fire Protection Association s
More informationAL800ULADA. NAC Power Extender. Installation Guide
AL800ULADA NAC Power Extender Installation Guide Rev. 122000 AL800ULADA - NAC Power Extender Overview: The Altronix AL800ULADA is an extremely cost effective 8 amp voltage regulated remote power supply/battery
More informationy Small dimensions. Easy to install in refrigerated counters or cold rooms
MAKING MODERN LIVING POSSIBLE Data sheet Thermostat Type KP The KP Thermostats are temperaturecontrolled electrical switches. All KP Thermostats have a single pole double throw (SPDT) changeover switch.
More informationMAINTENANCE & TROUBLESHOOTING GUIDE LEAK ALARM CHANNEL DRY OIL WATER AUX ALARM HIGH LOW CRITICAL WATER TANK LEVEL ALARM MODEL LDE-740 ADVANCE PAPER
PNEUMERCATOR Liquid Level Control Systems Electronic Systems Excluding LC2000 And TMS Series MAINTENANCE & TROUBLESHOOTING GUIDE 400 300 500 FUEL LEVEL LEAK MONITOR 1 200 600 OIL/GAS NORMAL WATER PNEUMERCATOR
More informationPRYCO, INC. FUEL CONTROL
PRYCO, INC. FUEL CONTROL and MONITORING SYSTEM Page 1 DETAIL SPECIFICATIONS INTRODUCTION PRYCO s FUEL CONTROL and MONITORING (FCM) system is the most sophisticated and powerful control tool available for
More informationCommercial and Light Industrial Fire Alarm Control Panel
FireSystem 2000 Commercial and Light Industrial Fire Alarm Control Panel Features Easily expandable. All new plug-in board design Two supervised audible circuits Lamp and system trouble circuit test Ground
More informationPipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual
MANUAL Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual Model FPT 130 Single Point Freeze Protection Heat Trace Control Table of Contents SCFP-CO-F130 Overview... 3 Installation...
More informationBeacon 410A Gas Monitor Operator s Manual
Beacon 410A Gas Monitor Operator s Manual Part Number: 71-0397 Revision: F Released: 12/5/17 www.rkiinstruments.com Product Warranty RKI Instruments, Inc., warrants gas alarm equipment sold by us to be
More informationTwo-Channel Gas Controller
Two-Channel Gas Controller Specifications subject to change without notice. USA 09 Page of DESCRIPTION Highly configurable, UL 0 performance-tested and -certified, and wall-mounted gas monitor; continuously
More informationBeacon 800 Gas Monitor Operator s Manual
Beacon 800 Gas Monitor Operator s Manual Part Number: 71-0037RK Revision: F Released: 4/18/17 www.rkiinstruments.com Product Warranty RKI Instruments, Inc. warrants gas alarm equipment sold by us to be
More informationDIESEL Engine Fire Pump Controllers Features
September 007 DIESEL Engine Fire Pump Controllers Features FD0 Diesel Engine Controllers 1-1 Printer / Recorder The industrial grade thermal printer is housed in a rugged steel enclosure within the controller.
More informationSeries. Access Power Controllers. Installation Guide
Series Access Power Controllers Installation Guide Models Include: Maxim11 - Power Supply 1: 12VDC @ 3.5 amp or 24VDC @ 2.7 amp. - Power Supply 2: 12VDC @ 3.5 amp or 24VDC @ 2.7 amp. - Sixteen (16) fuse
More informationECC-50/100C. Emergency Command Center
ECC-50/100C Emergency Command Center Canadian DF-60815:B Emergency Communications General Fire-lite s ECC-50/100C is a multipurpose emergency voice evacuation panel for fire applications, mass notification
More informationRemote Alarm Panels Features
Features 1-1 DFDAP-M / FDAP-M Remote Product Description Eaton s Remote s are designed to provide audible and visual alarms for Electric and Diesel Fire Pump Controllers. These remote panels are located
More informationMASTER PRESSRE MAINTANENCE CONTROLLER. Models PMCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc
MASTER PRESSRE MAINTANENCE CONTROLLER Models PMCE INSTRUCTION MANUAL C 2018 Master Control Systems, Inc TABLE OF CONTENTS Important Safety Information. Page 3 General Description and Installation.. Page
More informationINSTALLATION INSTRUCTIONS FOR MOUNTING KIT
RV Products Division INSTALLATION INSTRUCTIONS FOR 8330-5501 MOUNTING KIT 8330-752 CONTROL BOX KIT (12 VDC COOL ONLY) 9330B755 CONTROL BOX KIT (12 VDC HEAT/COOL) 8530-750 CONTROL BOX KIT (24 VAC COOL ONLY)
More informationRPSMLR2 RPSMLR2BB. Panic Device Power Controller Installation Guide LISTED. Rev
RPSMLR2 RPSMLR2BB Panic Device Power Controller Installation Guide LISTED Rev. 102715 Overview: RPSMLR2BB, RPSMLR2 will operate up to two (2) 24VDC panic hardware devices simultaneously. It is designed
More informationSP-1000X. Panic Device Power Controller Installation Guide. Rev
TM SP-1000X Panic Device Power Controller Installation Guide Rev. 120213 Overview: SP-1000X will operate up to two (2) 24VDC panic hardware devices simultaneously. It is designed to handle the high current
More informationGasScanner 4C. Four Channel Monitor. Operator s Manual. MINT-0280-XX Rev. A 02/25/08
GasScanner 4C Four Channel Monitor Operator s Manual MINT-0280-XX Rev. A 02/25/08 Product Warranty Matheson Tri-Gas., warrants gas alarm equipment sold by us to be free from defects in materials, workmanship,
More informationFIREFORCE 8 NOTIFICATION APPLIANCE CIRCUIT EXPANDER INSTALLATION & OPERATION MANUAL
FIREFORCE 8 NOTIFICATION APPLIANCE CIRCUIT EXPANDER INSTALLATION & OPERATION MANUAL THE GAMEWELL COMPANY PN: 71981 60 PLEASANT STREET ISSUE A ASHLAND, MA 01721 3/22/2001 This page intentionally blank ii
More informationLC1350 Level Controller
LC1350 Controller Description The Spirax Sarco LC1350 has two alarm channels that can be independently configured high or low to control the water level of a boiler, tank or vessel by operating a pump,
More informationECC-50/100(E) Emergency Command Center. General. Features. Emergency Voice Evacuation TYPICAL APPLICATIONS
ECC-50/100(E) Emergency Command Center DF-60734:A4 General Firelite s ECC-50/100 and ECC-50/100E are multipurpose emergency voice evacuation panels for fire applications, mass notification applications,
More informationE340 BOILER CONTROL INSTALLATION MANUAL
E-3451 JUNE 1999 E340 BOILER CONTROL INSTALLATION MANUAL DESCRIPTION The E340 Boiler Room Control is a microprocessor-based Boiler Management System designed to interface with existing Fireye D Series
More informationPOWER SOURCES MODEL NO. DESCRIPTION PRICE
POWER SOURCES BE-961-1 BE-961-2 BE-961-5 BE-961-6 Battery Eliminator - 120VAC to 9VDC Includes 10 Flex Conduit and Transformer Powers up to 3 ECLs or 3 EBs Battery Eliminator - Same as above with Supervisory
More informationACSI AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1089, REV. F
II 1400-2 ACSI 1406-04-AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1089, REV. F INSTALLATION Transformer Model BE31763001 by Basler Electric, Transformer Model 2010028 by Galaxy
More informationBeacon 110 Gas Monitor Operator s Manual
Beacon 110 Gas Monitor Operator s Manual Part Number: 71-0110RK Revision: H Released: 12/5/17 RKI Instruments, Inc. www.rkiinstruments.com Product Warranty RKI Instruments, Inc., warrants gas alarm equipment
More informationPressure switch KPU. Data sheet
Data sheet Pressure switch KPU The KPU switches are designed for use in refrigeration and air-conditioning systems to protect the systems from excessively low suction or too high discharge. They can also
More informationOperating & Maintenance Manual. Alert-4 Ethernet LCD Master Alarm
Operating & Maintenance Manual Alert-4 Ethernet LCD Master Alarm w w w. a m i c o. c o m Contents User Responsibility 4 Introduction 4 Features 5 Description of the Alarm 5 Shipment Details 5 The Alarm
More informationThree Phase Simplex. Installation (937) Installation Instructions and Operation/Troubleshooting Manual. Installation of Floats.
Three Phase Simplex Installation Instructions and Operation/Troubleshooting Manual This control panel must be installed and serviced by a licensed electrician in accordance with the National Electric Code
More informationCommStat 6. Controller for Redundant HVAC Systems PRODUCT DATA SHEET
CommStat 6 Controller for Redundant HVAC Systems PRODUCT DATA SHEET General Description The CommStat 6 HVAC controller is designed for controlling up to six redundant air conditioners in an E-House or
More informationFDF Foam Pump Controllers Features
FDF100 Diesel Engine Foam Pump Controllers 1-1 Product Description The FDF Series of Foam Pump Controllers are designed for use with foam concentrate injection, foam transfer and water mist systems for
More informationwww.severntrentservices.com CAPITAL CONTROLS Series 70CV3000 Chloromatic TM Intelligent Gas Flow Control Valve The Series 70CV3000 Chloromatic TM Intelligent Gas Flow Control Valve is designed to control
More informationWSK300 Multifunction Wall Control
WSK300 Multifunction Installation & Operating Instructions WARNING Hearth & Home Technologies disclaims any responsibility for, and the warranty will be voided by, the following actions: Installation and
More informationDual Technology Wall Mounted Occupancy Sensor. Manual & Specification
Dual Technology Wall Mounted Occupancy Sensor Manual & Specification PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH LOCAL ELECTRICAL CODES Douglas Lighting Controls Page 1 December 16, 2013 1. INTRODUCTION
More informationFUEL OIL DAY TANKS. SST Level Controller: UL 508 LISTED
FUEL OIL DAY TANKS SST Series - Engineering Submittal SST Series - Advanced Line Day Tanks Construction: UL 142 aboveground steel tank all seam welded, square, atmospheric tank of heavy gauge steel with
More informationIntroduction to Flow Switch
Introduction to TM Solutions Flow Detection, Switching & Control Flow switches detect a change in state from flow or no-flow within pipe or ducting. Correspondingly, the sensor inverts a contact to signal
More informationF PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd.
F-2000 PC and AO OUTPUT BOARDS INSTRUCTION MANUAL Blue-White R Industries, Ltd. 500 Business Drive Huntington Beach, CA 92649 USA Phone: 714-89-8529 FAX: 714-894-9492 E mail: sales@blue-white.com or techsupport@blue-white.com
More informationPump-Up Controller MODEL 4062
Pump-Up Controller 4-20mA Input/Scalable Output Seal Fail Monitoring Duplex Pump Alternation Hand-Off-Auto Controls Dual Run-time Meters RS-485/Modbus Communications DESCRIPTION The Model 4062 Pump-Up
More information20 Light Remote Annunciator
Light Remote Annunciator Owner s Manual Surface Mount Flush Mount 94-95- Standard Annunciator 94-, 94-95-, 95-4- 4- Annunciator w/remote Relay Panel 4-, 4-4-, 4-49-, 49-49-, 49- Time Multiplexed Annunciator
More informationSECTION LOW VOLTAGE LIGHTING CONTROLS
SECTION 26 09 26 LOW VOLTAGE LIGHTING CONTROLS PART 1 - GENERAL 1.01 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Division 1, "General Requirements", and Section
More informationAL600ULADA. NAC Power Extender. Installation Guide
AL600ULADA NAC Power Extender Installation Guide Rev. 122000 AL600ULADA - NAC Power Extender Overview: The Altronix AL600ULADA is an extremely cost effective 6.5 amp voltage regulated remote power supply/battery
More informationTYPE CM-2201 NELSON SINGLE POINT CIRCUIT MANAGEMENT SYSTEM
2 Line, 16 Characters/row LCD Display Temperature Input Range -50 C to +500 C -58 F to + 932 F Enclosure NEMA Type 4X Current Rating 30A max (resistive load only) Ambient Temperature -40 C to + 40 C -40
More informationAS950 REFRIGERATED SAMPLERS
AS950 REFRIGERATED SAMPLERS Applications Wastewater Collections Industrial Pretreatment Environmental Monitoring Stormwater Sampling has never been this easy. The AS950 Refrigerated Sampler makes programming,
More information