1 > Light weight glass reinforced polyester (GRP) Ex d enclosure > Weather resistant high performance red paint finish as standard > Break glass version supplied with test key > Push button version supplied with reset key and protection flap > Optional extras include stainless steel lift flap, duty and tag labels Yodalex range Manual call points designed for use in hazardous or harsh environments ATEX / IECEx / GOST Zone 0 0 For use in x x x x 9E00 Explosion Protection Global (IECEx) Gas explosion protection Ex d IIC T (Ta -ºC to +0ºC) Gb ust explosion protection Ex tb IIIC T8ºC b IP A Europe (ATEX) Ex d IIC T (Ta -ºC to +0ºC) Gb Gas explosion protection E II G Ex d IIC T (Ta -ºC to +0ºC) Gb ust explosion protection E II Ex tb IIIC T8ºC b IP A Certificates and approvals IECEx IECEx BAS Europe (ATEX) Baseefa08ATEX09X Certificates IECEx, ATEX, Brazil (METRO), Russia (GOST-R) WebCode MCPA Control evices /
2 Versions Break Glass (BG) E00 Push Button (PB) 00E00 Selection Table Version Version Enclosure colour Order number Art. no. Weight kg Break Glass (BG) red normal (R) MCP/BG/SP/Ex/A+B+C+/EU/R Manual Call Points, ATEX certification, Push Button (PB) red normal (R) MCP/PB/SP/Ex/A+B+C+/EU/R Break Glass (BG) red normal (R) MCP/BG/SP/EX/A+B+C+//R Manual Call Points, IECEx certification, Push Button (PB) red normal (R) MCP/PB/SP/Ex/A+B+C+//R Break Glass (BG) red normal (R) MCP/BG/SP/EX/A+B+C+/RU/R Manual Call Points, GOST R certification, Push Button (PB) red normal (R) MCP/PB/SP/Ex/A+B+C+/RU/R Note Accessories, variations and different unit colours are available, to order these please use the table below position of cable entries A B A B Contacts LE Resistors Enclosure colours C 9E00 Break glass call point Push button call point cable entries, supplied with (x) stopping plugs and (x) dust cap standard: change-over contact optional: change-over contacts optional: LE-status indication (up to V C) various resistance values on request additional colours on request C 9E00 / Control evices
3 Type Code Variations MCP / _ / _ / _ / _ / _ / _ / _ / _ / _ / _ Version break glass BG push button PB Contacts change over SP Explosion protection change over P standard standard x M0 with x stopping plugs and x dust cap glands to be ordered separately Certification ATEX EU IECEx GOST R Colour red R blue green yellow Ex A+B+C+ RU B G Y Accessories lift flap (break glass only) LF end of line resistor inline resistor EOL IL end of line and Inline resistor ILEOL Labels (please specify wording) LE signal duty label tag label LE T Control evices /
4 Technical ata Electrical data Rated operational voltage Switching capacity Contact element Schematic... 0 V C,... 0 V AC C... 0 V A resitive or A inductive V A resitive or inductive AC... 0 V A resistive or inductive standard: change-over contact optional: change-over contacts Normally open with series monitoring Internal switch connections armed 9 End of line device 8E00 89E00 The call point is supplied in two versions: supplied with or without a monitoring resistor. The version with the monitoring resistor should be connected as shown above. Check panel instructions to ensure the correct value resistor is fitted. If not required, remove and connect as shown in 'A' or 'B' Ratings: Vac: 0 V max. / V min. Imax: A resistive. Vdc: 0 V max. / V min. Contact resistance: 0 millioms max. Conductor size:. sq.mm max. per terminal. Normally open Normally closed End of 9 line device Monitoring device A B 8E00 80E00 When supplied without the monitoring resistor the call point should be connected as shown in 'A' or 'B' above. Legend 9 = Optional end of line resistor Ambient conditions Ambient temperature C Max. relative humidity 9 % at 0 C Mechanical data Enclosure material glass fibre reinforced polyester (GRP) Colour red egree of protection IP cable entries, supplied with (x) stopping plugs and (x) dust cap Connection Terminals way terminal block., mm Earth connection provided as standard Assembly / Installation Assembly via holes through the back box / Control evices
5 Accessories and Spare Parts esignation Illustration escription Group Order number Art. no. WebCode Cable gland Compound Barrier IIB + H and IIC 8/-0-PXSSK-M J Cable Glands Ex d and Ex e for all Types of Unarmoured Cables Note 0E00 Compound Barrier Cable Glands Ex d and Ex e for all Types IIB + H and IIC 8/-0-PXK-M0 88 8I E00 of Armoured Cables Approvals of cable entries have to be observed. imensional rawings (All imensions in mm / inches) - Subject to Alterations mm /.9, mm /. ", mm /. ", mm /. " mm /.9 ", mm /. " 98 mm /.9 " Break glass call point 0E00 Push button call point We reserve the right to make alterations to the technical data, dimensions, weights, designs and products available without notice. The illustrations cannot be considered binding. 0E00 Control evices /
Flameproof Manual Call Points Series MCP
> Light weight glass reinforced polyester (GRP) Ex d enclosure > Weather resistant high performance red paint finish as standard > Break glass version supplied with test key > Push button version supplied
More informationFlameproof Manual Call Points Series MCP
> Light weight glass reinforced polyester (GRP) Ex d enclosure > Weather resistant high performance red paint finish as standard > Break glass version supplied with test key > Push button version supplied
More informationExplosion Proof Combination Signal db (A) / 5 Joule Series YL60
www.stahl.de Explosion Proof Combination Signal - 110 db (A) / 5 Joule > Omnidirectional high output sounder 110 db (A) / 1 m > 5 Joule xenon strobe > 2 stage alarm, independently selectable 2nd stage
More informationGRP Flameproof Combination Signal db(a) / 5 Joule Series YL6S
www.stahl.de > Corrosion resistant omnidirectional high output sounder > Integrated Ex d enclosure > Extreme temperature range > 3 stage alarm with independant tone selection for V DC systems > IP66 IP67
More informationMultiple Status Indicators Series MEXE, MS25, MS35, MS45, MS55
www.stahl.de > Pre-wi ready-to-use multi-signalling unit > Corrosion resistant > Suitable for offshore / onshore harsh environments > Incorporates the FX15 GRP beacon YA90 for visual audible notification
More informationFlameproof Manual Call Points
Operating instructions Additional languages www.r-stahl.com CS & Clifford & Snell Contents General Information.... Manufacturer.... Information regarding the operating instructions.... Further documents....
More informationIntegrated Solutions Low Voltage Systems
Integrated Solutions Low Voltage Systems 612 Contents Energy Distribution Overview Module Technology 8146 614 Overview Flameproof Enclosures 8220 614 Overview Flameproof Enclosures 8261 614 Overview CUBEx
More informationManual Alarm Call Points
Manual Alarm Call Points MEDC provide a range of manual alarm call points specifically designed for the purpose of raising an alarm in the case of an emergency in a hazardous area. The call points can
More informationFire Alarm or Emergency Call Points
Class I, Div. 2, Zone 2 Touch-safe coated glass for finger activation. Class I, Div. 2, Zone 2 Push to activate. Class I, Div. 1 Push to activate. Key switch to reset. These manual fire alarm call points
More informationExplosion Proof Combination Signal db (A) / 5 Joule
Explosion Proof Combination Signal - Operating instructions Additional languages www.r-stahl.com General information Contents 1 General information...2 1.1 Manufacturer...2 1.2 Information regarding the
More informationSensepoint. Fit For Purpose Flammable, toxic and Oxygen versions available High performance, low cost Suitable for new and retro fit applications
Sensepoint The Sensepoint range of flammable, toxic and Oxygen gas detectors offer users a high quality, low cost solution to their industrial gas monitoring needs. Sensepoint Fit For Purpose Flammable,
More informationIECEx Certificate. INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres
INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.: Certificate history: Status:
More informationINSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres
INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres 1) Introduction The BExBG05D-SIL is a flameproof beacon which is certified
More informationOfficine Meccaniche M.A.M. series for command, control, signaling and/or automation. DOCUMENT IS-EJB-A-14 rev. 0
Officine Meccaniche M.A.M. Apparecchiature Antideflagranti DOCUMENT IS-EJB-A-14 rev. 0 Instructions Flameproof enclosures EJB../W series for command, control, signaling and/or automation Emission date:
More informationEN54-5, ATEX and IECEx approved Highly durable Automatic reset after cooling Range of alarm temperatures
EN54-5, ATEX and IECEx approved Highly durable Automatic reset after cooling Range of alarm temperatures HDL-3-EX* Complete and ready to install Heat Detector with Ex-certified Box, Cable gland and wiring
More informationINSTRUCTION MANUAL (ATEX / IECEx)
INSTRUCTION MANUAL (ATEX / IECEx) BExS110D and BExS110D-R Sounder For use in Flammable Gas and Dust Atmospheres BExS110D BExS110D-R 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT DO NOT
More informationPRODUCT ATEX IECEx UL ULC CSA Inmetro CUTR CQST ABS SIL IP Rating Page DB7 66 / DB12 66 / DB15 66 / DB1 DB3 DB3V DB3B
Horns and Sounders The MEDC range of horns and sounders are suitable for a wide variety of applications and feature a variety of tone settings and traditional bells. Sounders and Horns are used to warn
More informationINSTRUCTION & SERVICE MANUAL
INSTRUCTION & SERVICE MANUAL D2xC1 ALARM HORN AND STROBE For Use In Hazardous Locations 3) Ratings and Markings 3.1 ATEX / IECEx certification The D2xC1 Alarm Horn and Strobe complies with the following
More informationDB4 Range - SPEAKERS - Up to 25 Watts
DB Range - SPEAKERS - Up to 5 Watts Hazardous Location, Weatherproof Features UL listed for USA and Canada Class I, Div, Groups A, B, C & D. Class I, Zone, AExd IIC T. CSFM approved. ATEX approved. NEMA
More informationDuct heaters for ATEX/IECEx hazardous areas or in non-atex version
for ATEX/IECEx hazardous areas or in non-atex version * Non contractual picture Warning It is imperative to read these instructions carefully before installing or maintaining the equipment. MI200EN 09/2017
More informationHazardous Area Signalling
Hazardous Area Signalling Model# Combination Alarm Horn Sounders and Beacons/Lights Approval Enclosure Zone / Division IS-mC1 L.E.D. 37 BExCS110-05 Xenon 5 BExCS110 -L2 L.E.D. 5 D1xC1X05R Xenon 17 D1xC1X10R
More informationINSTRUCTION MANUAL. E2xB05 & E2xB10 Xenon Beacons For use in Hazardous Locations
INSTRUCTION MANUAL E2xB05 & E2xB10 Xenon Beacons For use in Hazardous Locations 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT DO NOT OPEN WHEN ENERGISED POTENTIAL ELECTROSTATIC CHARGING
More informationIndoor/outdoor resistance thermometer Model TR60
Temperature Indoor/outdoor resistance thermometer Model TR60 WIKA data sheet TE 60.60 for further approvals see page 2 Applications Ambient temperature measurement Air-conditioned rooms, cold-storage rooms,
More informationIECEx Certificate of Conformity
IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.:
More informationInspection Light LED 6149/2. Operating instructions EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN
Inspection Light LED Operating instructions Additional languages www.stahl-ex.com Contents 1 General Information...3 1.1 Manufacturer...3 1.2 Information regarding the operating instructions...3 1.3 Conformity
More informationINSTRUCTION MANUAL (ATEX/IECEx/SIL2)
INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExS110D-SIL Flameproof Sounders For use in Flammable Gas Atmospheres BExS110D-SIL 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT DO NOT OPEN WHEN
More informationExplosion-proof Immersion Heater Type D-8660
Explosion-proof Immersion Heater Type D-8660 Sinus Jevi has developed explosionproof Ex de heating equipment, for hazardous area. The flame-proof (d) enclosures have been designed for non save areas to
More informationstandards: standards:
INSTRUCTION MANUAL D2xB1LD2 LED Beacons For use in Hazardous Locations 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT DO NOT OPEN WHEN ENERGISED POTENTIAL ELECTROSTATIC CHARGING HAZARD
More informationELECTRICAL EX EQUIPMENT
ELECTRICAL EX EQUIPMENT in hazardous areas Enclosures Reliable Customized Solutions Leader in Explosion Proof Protections CB Control Panel Configuration - Gas group IIB / Dust group IIIC Ex d enclosures
More informationFixed Gas Detection System/Meridian CERTIFICATION
The marking shall include 2 Wire Aluminum Transmitter 3/4 Wire Aluminum Transmitter 2 Wire Stainless Steel Transmitter (PN: 096-3521) (PN: 096-3522) (PN: 096-3525) Ex db [ia Ga] IIC T4 Gb Ex db [ia Ga]
More informationImmersion heaters for ATEX/IECEx hazardous areas or in non-atex version
for ATEX/IECEx hazardous areas or in non-atex version * Non contractual picture Warning It is imperative to read these instructions carefully before installing or maintaining the equipment. MI100EN 09/2017
More informationPhoenix Explosion-proof. Pan & Tilt heads and Camera Housings for potentially exposed environments. Answers for infrastructure.
Phoenix Explosion-proof Pan & Tilt heads and Camera Housings for potentially exposed environments Answers for infrastructure. Video monitoring under extreme conditions Security Products from Siemens is
More informationmanual addendum DELPHI Ex
manual addendum DELPHI Ex II 2G Ex eb IIC T4 Gb II 2D Ex tb IIIC T135 C IP65 Db Tamb=-20 +40 C Reference list: Norm (last issue) Title Dir. 2014/34/UE EN 60079-31 EN60079-0 EN60079-7 Equipment and Protective
More informationCirculation heaters for ATEX/IECEx hazardous areas or in non-atex version
for ATEX/IECEx hazardous areas or in non-atex version * Non contractual picture Warning It is imperative to read these instructions carefully before installing or maintaining the equipment. MI500EN 09/2017
More informationApproved by: Document no.: EGT
ET Page 1 of 6 TECHNICL MNUL EXPLOSION PROOF MNUL CLL POINT / PUSH BUTTON TEX Marking: Code: II 2D EPL b, Db Ex d IIC T6 IP66 Ex tb IIIC T85 C Marking details: Please note that every care has been taken
More informationEx LED light fittings
About us TEP Ex is a regional leader in manufacturing of explosion-protected electrical equipment. Through continuous development of new products and markets, modernization of technology and investment
More informationOilSET Installation and Operating Instructions. Oil Separator Alarm Device
Labkotec Oy Myllyhaantie 6 FI-33960 PIRKKALA FINLAND Tel: +358 29 006 260 Fax: +358 29 006 1260 18.11.2010 Internet: www.labkotec.fi 1/10 OilSET-1000 Oil Separator Alarm Device Copyright 2010 Labkotec
More informationOperating Instructions
Important information: These instructions contain safety information, read and follow them carefully. Dialight will not accept any responsibility for injury, damage or loss which may occur due to incorrect
More informationDräger Polytron 5700 IR Detection of flammable gases and vapours
Dräger Polytron 5700 IR Detection of flammable gases and vapours The Dräger Polytron 5700 IR is a cost effective explosion-proof transmitter for the detection of flammable gases in the lower explosive
More informationProduct manual reducers, adapters, plugs etc. INDEX ELEKTRO BV Harregatplein VP Zuidland Netherlands
Product manual reducers, adapters, plugs etc. INDEX ELEKTRO BV Harregatplein 15 3214 VP Zuidland Netherlands T. +31(0)181 452120 http/www.indexelektro.nl email info@indexelektro.nl Purpose of these instructions
More informationTBSF/CBSF Stainless Steel Flat Roof Screwed Terminal Box Zones 1&2, 21&22
Hazardous Area Electrical Equipment Made TBSF/CBSF Stainless Steel Flat Roof Screwed Terminal Box Zones 1&2, 21&22 Index Dimension Sheet Catalogue Information Leaflet Web Links TBSF/CBSF Information Page
More informationPYROS. Código: FT-PY01-I Revisión: TECHNICAL DATA. Polycarbonate tube of 4 mm. thickness LIGHT FITTING. Laquered steel painted white
. TECHNICAL DATA LIGHT FITTING REFLECTOR Polycarbonate tube of 4 mm. thickness Laquered steel painted white END CAPS Aluminium 2030 (polyester paint RAL 7047) POWER SOURCE LAMP TYPE 220-240V, 50/60Hz T8
More informationDICTATOR Hold-Open Systems for Hazardous Areas
DICTATOR for Hazardous Areas Products to be used in hazardous areas obviously have to meet special demands. The European ATEX directives (first the EN 94/9/EG and then the directive 2014/34/ EU) brought
More informationIndustrial & Hazardous Area Electrical Equipment
Industrial & azardous Area Electrical Equipment 2017 Abtech has been supplying electrical connection products to hazardous and industrial markets since the 1970 s. Our range includes hazardous area lighting,
More informationWE PROTECT HAZARDOUS ENVIRONMENTS EXPLOSION-PROOF AND HAZARDOUS LOCATION VISUAL & AUDIBLE SIGNALING PRODUCTS
WE PROTECT HAZARDOUS ENVIRONMENTS EXPLOSION-PROOF AND HAZARDOUS LOCATION VISUAL & AUDIBLE SIGNALING PRODUCTS 100+ YEARS Federal Signal is recognized as one of the industry s leading suppliers of safety
More informationINSTRUCTION MANUAL. D2xB1XH1 & D2xB1XH2 Xenon Beacons For use in Hazardous Locations
INSTRUCTION MANUAL D2xB1XH1 & D2xB1XH2 Xenon Beacons For use in Hazardous Locations synchronization requirements of UL1971 & UL1638 / CAN/ULCS526. 2.2 NEC & CEC Class / Division Ratings for US / Canada
More informationCertificate of Compliance
Certificate of Compliance Certificate: 2557738 Master Contract: 256526 Issued to: Bartec Varnost d.o.o Cesta 9 avgusta 59 Zagorje ob Savi, 1410 Slovenia Attention: Janez Gajski The products listed below
More informationIECEx Certificate of Conformity
IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.:
More informationCCAC. Ex d. - Zone 1, 2, 21, 22 - Group IIC - Aluminium junction boxes - Choice of 5 sizes - IP66. Stainless steel bolts.
Ex d CCAC - Zone 1, 2, 21, 22 - Group IIC - Aluminium junction boxes - Choice of 5 sizes - IP66 Stainless steel bolts Polyester coating External earth screw Grub screws for opening lid External earth screw
More informationDB5 Intrinsically Safe Sounder Type DB-5
Operating Instructions RTK Instruments Limited DB5 Intrinsically Safe Sounder Type DB-5 Description The DB5 Sounder is a strong, lightweight warning sounder, CENELEC certified to Ex II 1G EExia IIC T4
More informationDräger Polytron 5200 CAT Detection of flammable gases and vapours
Dräger Polytron 5200 CAT Detection of flammable gases and vapours The Dräger Polytron 5200 CAT is a cost-effective explosion-proof transmitter for the detection of flammable gases in the lower explosion
More informationpower HaZ-LOC MAGNET-SCHULTZ OF AMERICA Harness the of collaborative innovation Hazardous location Engineered for safety critical markets
Harness the power of collaborative innovation MANET-SCHULTZ OF AMERICA S P E C I A L I S T S I N E L E C T R O M A N E T I C E V I CES Magnet-Schultz of America, Inc. 401 Plaza rive Engineered for safety
More informationDB1 Range - HORNS - Up to 103 db(a)
DB1 Range - HORNS - Up to 103 db(a) Explosion-proof, Weatherproof Features UL listed Class I, Div. 1, Groups C & D. Class 1, Zone 1. ATEX approved. NEMA 4x, IP66. Certified temperature: 13 F to +158 F.
More informationRosemount 148 Temperature Transmitter. Quick Start Guide , Rev GA September 2016
Rosemount 148 Temperature Transmitter 00825-0100-4148, Rev GA NOTICE This guide provides basic guidelines for the Rosemount 148. It does not provide instructions for detailed configuration, diagnostics,
More informationRegulated Ex-Heater HEX with internal controller, HEX with external controller II 3 G II 3 D
Regulated Ex-Heater HEX5-1.08 with internal controller, HEX5-2.08 with external controller II 3 G II 3 D Instruction Manual Version 1.02.00 Dear customer, we have made up this operating manual in such
More informationCertification Supplement Manual
PROCESS ANALYSERS SERVOTOUGH Oxy Gas Analyser Certification Supplement Manual Part Number: 01910008B Revision: 9 Language: UK English This page intentionally blank SERVOTOUGH Oxy Certification Supplement
More informationDräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors
Dräger Polytron 5700 Fixed Gas Detector Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors Dräger Polytron 5700 Including e-box for increased safety wiring The Dräger
More informationEarth-Rite II PLUS Static Earthing System
READ MANUAL BEFORE COMMENCING WITH INSTALLATION EN Earth-Rite II PLUS Static Earthing System P1 PLUS - DC Supply Installation & Operating Instructions The safety of any system incorporating the equipment
More informationINSTRUCTION MANUAL. D1xB2XH2 Xenon Beacon For use in Hazardous Locations. 2) Rating & Marking Information
INSTRUCTION MANUAL D1xB2XH2 Xenon Beacon For use in Hazardous Locations 2) Rating & Marking Information 2.1 Public Mode Fire Alarm Ratings The D1xB2XH2 is certified for use as public mode visual alarm
More informationINSTRUCTION MANUAL. D1xB2XH1 Xenon Beacon For use in Hazardous Locations. 2) Rating & Marking Information
INSTRUCTION MANUAL D1xB2XH1 Xenon Beacon For use in Hazardous Locations 2) Rating & Marking Information 2.1 Public Mode Fire Alarm Ratings The D1xB2XH1 is certified for use as public mode visual alarm
More informationWeb: LGM Products Ltd.
Hazardous Area Product Brochure Email: sales@lgmproducts.com Web: www.lgmproducts.com 2015 LGM Products Ltd. About us Formed in 1988, we are proud to be an independent service orientated company. LGM Products
More informationUSER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 218
CONTENT 1. Manufacturer 1 2. General safety informations 1 3. Purpose 2 4. Product compliance 2 5. Degree of protection and technical data 2 6. Type 3 7. Mounting and installation 3 8. Dimensions 6 9.
More informationSinus Jevi (Explosion-Proof) Condens Heaters
Sinus Jevi (Explosion-Proof) Condens Heaters Heating elements for dehumidification of sealed switchboards and control cabinets. Due to temperature limitations on e.g. print and plastic cabinets it is important
More informationGlobal Series. Installation and Maintenance Instructions. Model G-STR Strobe Beacon. For Use in Hazardous Locations
Global Series Model G-STR Strobe Beacon For Use in Hazardous Locations Ex d Surface Mount Ex de Surface Mount Installation and Maintenance Instructions 25500185 Rev. B4 1217 Printed in U.S.A. Limited Warranty
More informationCertification Supplement Manual
PROCESS ANALYSERS SERVOTOUGH FluegasExact (2700) Gas Analyser Certification Supplement Manual Part Number: 02700008D Revision: 2 Language: UK English Blank CONTENTS 1 INTRODUCTION 2 EC DECLARATION OF CONFORMITY
More informationAdditional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.
Additional Operating Instructions SITRANS F Vortex flowmeters Ex-d Edition 09/208 CONTENTS Safety instructions 3. General notes... 3.2 EU conformity... 3.3 Approval according to the IECEx scheme... 3.4
More informationTYPE APPROVAL CERTIFICATE
TYPE APPROVAL CERTIFICATE Certificate No: E-14378 This is to certify: That the Pilot Device with type designation(s) Pilot device Issued to BARTEC GmbH BAD MERGENTHEIM, Germany is found to comply with
More informationElectrical Installations Design, Selection, Erection and Inspection
IECEx International Conference 2018 Jakarta, Indonesia Electrical Installations Design, Selection, Erection and Inspection IECEx International Conference 2018 Jakarta, Indonesia Peter Thurnherr thuba Ltd.,
More informationofficial distributor of Newson Gale Ltd.
Continuous Ground Loop Monitoring with visual indication. The precision and reliability of the provides enhanced safety and security by continuously testing the connection of the clamp to the container
More informationTECHNICAL MANUAL EXPLOSION PROOF STATUS LIGHT / LAMP BSL 125 / BSL 150. Scope: EXcite USER MANUAL BSL 125 / BSL 150. Date:
Page 1 of 9 TECHNICL MNUL EXPLOSION PROOF STTUS LIGHT / LMP TEX Marking: Code: II 2GD EPL Gb, Db Ex d IIC T4/T5/T6 IP66 Ex tb IIIC TXXX C Marking details: Please note that every care has been taken to
More informationIECEx Certificate of Conformity
INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com issue No.:2 Status: Current Certificate history:
More informationTECHNICAL MANUAL EXPLOSION PROOF MANUAL CALL POINT BCP 135. Scope: EXcite USER MANUAL BCP 135. Date: Page: Page 1 of 6.
Pae 1 of 6 TECHNICL MNUL EXPLOSION PROOF MNUL CLL POINT TEX Markin: Code: II 2GD EPL Gb, Db Ex d IIB+H2 T6 IP66 Ex tb IIIC T85 C Markin details: Please note that every care has been taken to ensure the
More informationCable Glands. Description Introduction to Cable Glands 399. EEXe Series EEXe Series. A2F, E1FX/E2FX, E1FW/E2FW and T3 Series
Description Page Introduction to Cable Glands 399 EEXe Series 400-401 Polyamide Cable Glands for Unarmored Cable Increased Safety EEXe Series Ex e Certified Ex I Application Entry Thread Seal A2F, E1FX/E2FX,
More informationQuick Start Guide For the
A Leader in Level Measurement Quick Start Guide For the Universal IV Lite and Universal IV Pro Model Transmitters 2-Wire RF Admittance / Capacitance Level Measurement System with HART Protocol For Assistance
More informationUSER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 236
CONTENT 1. Manufacturer 1 2. General safety informations 1 3. Purpose 2 4. Product compliance 2 5. Degree of protection and technical data 2 6. Type 3 7. Mounting and installation 3 8. Dimensions 6 9.
More informationPRODUCT OVERVIEW. Light fittings, boxes & custom built control panels for explosive atmospheres
PRODUCT OVERVIEW Light fittings, boxes & custom built control panels for explosive atmospheres LIGHT FITTINGS, BOXES & CUSTOM BUILT CONTROL PANELS FOR EXPLOSIVE ATMOSPHERES Light fittings for all zones
More informationAn optional Ex e terminal chamber is available (see certification section for further details).
Technical Manual for the Sounder DB3B Manuel technique du Générateur de sons DB3B Technische Bedienungsanleitung für den Schallgeber DB3B Manual técnico para a sirene - DB3B Please note that every care
More informationINSTRUCTION MANUAL (ATEX / IECEx)
INSTRUCTION MANUAL (ATEX / IECEx) BExBG15E and BExBG10E Flameproof / Increased Safety Xenon Beacons For use in Flammable Gas and Dust Atmospheres 1) Introduction The BExBG15E and BExBG10E beacons are flameproof
More informationIntrinsically Safe Solutions
Intrinsically Safe Solutions INSTALLATION MANUAL 04/12/14 Rev D DOC-01-029 Documentation Feedback Your feedback helps us keep our documentation up to date and accurate. If you have any comments or suggestions
More informationBeacons, Lights & Strobes
Beacons, Lights & Strobes MEDC's range of beacons, including flashing, steady-state indicators and rotating units, provide solutions for potentially explosive and harsh environmental conditions. These
More informationGS100-ATEX. Hazardous Areas Infra-Red Beam PULSE MODULATED ACTIVE INFRA-RED BEAM FOR HAZARDOUS AREAS ZONE 1 OR ZONE 2 GENERAL
GS100-ATEX Hazardous Areas Infra-Red Beam PULSE MODULATED ACTIVE INFRA-RED BEAM FOR HAZARDOUS AREAS ZONE 1 OR ZONE 2 GENERAL The GS100 beam set is a detection device only, and is designed to be used in
More informationDräger Polytron 5720 IR Toxic Gas Detection
Dräger Polytron 5720 IR Toxic Gas Detection The Dräger Polytron 5720 IR is a cost-effective explosion proof transmitter for the detection of carbon dioxide in volume percentage or ppm It uses a high-performance
More informationDM1153H-Ex / DM1154H-Ex Manual call point 'Heavy Duty'-Ex
DM1153H-Ex / DM1154H-Ex Manual call point 'Heavy Duty'-Ex Interactive, for explosion-hazard area of zones 1 and 2 AlgoRex Manual call point to the interactive fire detection system with microprocessor,
More informationDräger Polytron 5100 EC Detection of toxic gases and vapors
Dräger Polytron 5100 EC Detection of toxic gases and vapors The Dräger Polytron 5100 EC is a cost-effective explosion proof transmitter for the detection of toxic gases or oxygen. It uses a high performance
More informationRosemount 214C Sensor. Quick Start Guide , Rev AF August 2017
Rosemount 214C Sensor 00825-0400-2654, Rev AF NOTICE This guide provides basic guidelines for Rosemount 214C Sensor models. If the sensor was ordered assembled to a temperature thermowell or transmitter,
More informationIllumination unit For sight glass level indicator Model LGI
Level Illumination unit For sight glass level indicator Model LGI WIKA data sheet LM 33.02 for further approvals see page 2 Applications Better identification of liquid and gaseous phase Direct indication
More informationDrive Technology \ Drive Automation \ System Integration \ Services * _0817* Inquiry Forms for Explosion-Proof Gearmotors
Drive Technology \ Drive Automation \ System Integration \ Services *23511257_0817* Inquiry Forms for Explosion-Proof Gearmotors Edition 08/2017 23511257/EN SEW-EURODRIVE Driving the world Inquiry forms
More informationMANUAL CALL POINT Intrinsically Safe (EExia), Weatherproof BG3 Range ATEX
MAUAL CALL POIT Intrinsically Safe (EExia), Weatherproof BG3 Range ATEX ow Chinese Certified Introduction This manual fire alarm call point is designed in accordance with the latest draft European Call
More informationExp, pressurized systems
Exp, pressurized systems ATEX approved Principle, requirements and recommendation Exp, explosion protected systems The principle of a pressurized apparatus The entry of a surrounding atmosphere into the
More informationEJBX. Ex d. AISI 316L stainless steel. - Zone 1, 2, 21, 22 - Group IIB+H2 - Stainless steel junction boxes - Choice of 13 sizes - IP 66 / 67
Ex d EJBX AISI 316L stainless steel - Zone 1, 2, 21, 22 - Group IIB+H2 - Stainless steel junction boxes - Choice of 13 sizes - IP 66 / 67 Quartz sand blasting Warning labels Mounting bracket Silicone gasket
More informationManual Power relay SR853
Manual Power relay SR853 Product types SR853.8.x.x, Rev. 1 SR853 manual page2 The symbols WARNING, CAUTION, NOTE This symbol warns of a serious hazard. Failure to observe this warning may result in death
More informationDräger Polytron 8000 Stationary gas detector (EC)
Dräger Polytron 8000 Stationary gas detector (EC) The microprocessor-based transmitter can be equipped with various electrochemical DrägerSensors. This way, you can easily detect oxygen and various toxic
More informationDräger Polytron 5200 CAT Detection of flammable gases and vapours
Dräger Polytron 5200 CAT Detection of flammable gases and vapours The Dräger Polytron 5200 CAT is a cost-effective explosion-proof transmitter for the detection of flammable gases in the lower explosion
More informationTechnical Manual for the Alarm Pull Station PH1
Technical Manual for the Alarm Pull Station PH1 Please note that every care has been taken to ensure the accuracy of our technical manual. We do not, however, accept responsibility for damage, loss or
More informationNGC-20-C-E and NGC-20-CL-E
Field-mounted Electronic heat-tracing control unit Product overview The aychem NGC-20 is an electronic heat-tracing control unit featuring the benefits of local control and the capability for central monitoring.
More informationHOW LIMIT AND BASIC SWITCHES CAN STOP MACHINES FROM GOING BOOM. A Honeywell White Paper
HOW LIMIT AND BASIC SWITCHES CAN STOP MACHINES FROM GOING BOOM. A Honeywell White Paper How Limit and Basic Switches Can Stop Machines from Going Boom White Paper sensing.honeywell.com 2 Abstract In hazardous
More informationDatasheet - AZM 161SK-12/12RK-024
30.10.2017-13:15:19h Datasheet - AZM 161SK-12/12RK-024 Solenoid interlock / AZM 161 Preferred typ Thermoplastic enclosure Double-insulated Interlock with protection against incorrect locking. 130 mm x
More informationNexLED. Ex e LED BULKHEAD. Features. Standard Specification. International Approvals. NexLED with Exit Sign kit
NexLED Ex e LED BULKHEAD 62 NexLED with Exit Sign kit The NexLED bulkhead utilises the latest LED technology to provide instant illumination. The NexLED requires no re-lamping making it virtually maintenance
More informationINERIS 01ATEX0060 (standard) TR CU (marking upon request, ordering code to be required)
FLUORESCENT LIGHTING RMS-560.. Series - Fluorescent lighting fixtures TECHNICAL FEATURES RMS.. series lighting fixtures are ideally suited for ON and OFF-SHORE applications and all kinds of industries
More informationTemperature Measurement Transmitters for field mounting
Siemens AG 07 Overview Application The SITRANS TF can be used everywhere where temperatures need to be measured under particularly harsh conditions. For that reasons users from all industries have opted
More information