1 1 Copyright Information Copyright 2013 HCPro, Inc. The Adopting the 2012 Life Safety Code : Prepare for Fire Safety Equipment Testing and Inspection Changes materials package is published by HCPro, Inc. For more information, please contact us at: 75 Sylvan Street, Suite A-101, Danvers, MA Attendance at the webcast is restricted to employees, consultants, and members of the medical staff of the Licensee. The webcast materials are intended solely for use in conjunction with the associated HCPro webcast. The Licensee may make copies of these materials for internal use by attendees of the webcast only. All such copies must bear the following legend: Dissemination of any information in these materials or the webcast to any party other than the Licensee or its employees is strictly prohibited. In our materials, we strive to provide our audience with useful and timely information. The live webcast will follow the enclosed agenda. Occasionally, our speakers will refer to the enclosed materials. We have noticed that non-hcpro webcast materials often follow the speakers presentations bullet-by-bullet and page-bypage. However, because our presentations are less rigid and rely more on speaker interaction, we do not include each speaker s entire presentation. The enclosed materials contain helpful resources, forms, crosswalks, policies, charts, and graphs. We hope that you will find this information useful in the future. Although every precaution has been taken in the preparation of these materials, the publisher and speaker assume no responsibility for errors or omissions, or for damages resulting from the use of the information contained herein. Advice given is general, and attendees and readers of the materials should consult professional counsel for specific legal, ethical, or clinical questions. HCPro, Inc. is not affiliated in any way with The Joint Commission, which owns the JCAHO and Joint Commission trademarks; the Accreditation Council for Graduate Medical Education, which owns the ACGME trademark; or the Accreditation Association for Ambulatory Health Care (AAAHC). 2

2 If you are not hearing music or you are experiencing any technical difficulties, please contact our help desk at 888/ We will begin shortly! 3 4

3 Presented by: Brad Keyes, CHSP Brad Keyes, CHSP, is the owner of KEYES Life Safety Compliance and his expertise is in the management of the Life Safety Program, including the Environment of Care and Emergency Management programs. Keyes analyzes and develops leadership effectiveness and efficiency in work processes, focusing on assessing an organization s preparedness for survey, evaluating processes in achieving preparedness, and guiding organizations toward compliance. 5 The New 2012 Life Safety Code The Centers for Medicare & Medicaid Services (CMS) announced in late 2011 that they are reviewing the 2012 edition of the Life Safety Code for adoption The last time they upgraded, they went from the 1985 edition to the 2000 edition, effective March 11, 2003 which took 3-years! 6

4 The New 2012 Life Safety Code CMS is required by law, to follow the federal rule-making procedure when they want to update to a newer edition of the Life Safety Code It requires CMS to conduct a due-diligence investigation, identifying the costs involved in making the change 7 The New 2012 Life Safety Code It also requires them to publish a notice of a proposed rule outlining their intent to adopt the 2012 edition, and allow 60 days for the public to respond CMS then is required to respond to all of the comments made by the public and make appropriate changes in their proposed rule 8

5 The New 2012 Life Safety Code Look for CMS to publish a proposed rule on adopting the 2012 edition of the LSC later this fall. The public will have 60 days to make comments on the proposed rule It will take up to 12 months for CMS to review all of the public comments before they issue their final rule 9 The New 2012 Life Safety Code Then CMS will publish their final rule on adopting the 2012 edition of the LSC in the Federal Register and it will become effective within 60 days after that Look for the 2012 edition of the LSC to be adopted and become effective in late 2014 or early

6 The New 2012 Life Safety Code The myth surrounding this rule-making procedure is that Congress must vote on the change to adopt the 2012 edition of the LSC That is not true! Congress has 60 days to review and comment on the final rule once it is published in the Federal Register But they do not vote on it 11 The New 2012 Life Safety Code It is no wonder it takes 3 years to move to a newer edition of the Life Safety Code CMS is held to this rule-making process and they do not have the authority to adopt a newer edition of the Life Safety Code without following the process 12

7 The New 2012 Life Safety Code This rule-making process is required by all Federal Government agencies, and is a result of the Administrative Procedure Act of 1946 The APA is designed to prevent a dictatorial agency of the government making changes in their rules without the public knowledge and opportunity to comment 13 The New 2012 Life Safety Code While this is a cumbersome and slow process to adopting a newer edition of the codes, the process is designed to protect the interests of the public It may not be a perfect system but what part of government is? 14

8 The New 2012 Life Safety Code All accreditation organizations must enforce the edition of the LSC that CMS has adopted, unless the hospital or nursing home does not seek Medicare & Medicaid reimbursement There are four (4) hospital accreditation programs who have received deeming authority from CMS: Healthcare Facilities Accreditation Program (HFAP- 1945) Det Norske Veritas Healthcare, Inc. (DNV- 2008) The Joint Commission (TJC- 2009) Center for Improvement in Healthcare Quality (CIHQ- 2013) 15 The New 2012 Life Safety Code All hospital accreditation organizations are required to survey for compliance with the 2000 edition, and cannot move to the more recent edition until CMS adopts it There are many advantages (and some disadvantages) to the facility manager of adopting the 2012 edition of the LSC 16

9 The New 2012 Life Safety Code There are significant changes in store for hospitals and nursing homes when the 2012 edition is finally adopted In a previous webinar, we covered the changes involving the new 2012 Life Safety Code itself 17 The New 2012 Life Safety Code Today we will cover some of the more significant changes involving testing and inspection of fire safety features Most of these testing and inspection requirements are found in standards referenced by the LSC, such as NFPA 10, NFPA 17A, NFPA 25, NFPA 72, NFPA 80, NFPA 96, NFPA 110, NFPA 241 [Code references are to the 2012 edition of the Life Safety Code otherwise stated] 18

10 Polling Question At this time, how prepared is your organization for the new 2012 edition of the Life Safety Code? A) 100% All ready and prepared B) 75% Ready C) 50% Some-what ready D) 25% Not very ready E) 0% Haven t even begun to think about it We will review the results of this polling question later in the program 19 Fire Door Testing and Inspection Sections and require all fire doors to be inspected and tested (per NFPA 80) The new NFPA 80 requires the individual conducting the inspection to have knowledge and understanding of the operating components of the door being inspected 20

11 Fire Door Testing and Inspection So, what qualifies the individual to have knowledge or understanding? NFPA 80 does not specify, so that means you get to decide who is qualified 21 Fire Door Testing and Inspection Unless they develop their own criteria, the authorities having jurisdiction (AHJs) will want to see how you determined that the designated individual is knowledgeable and understanding on door operations 22

12 Fire Door Testing and Inspection So, make sure you have some sort of evaluation documented that objectively addresses the qualifications of the individual It may be based on: Experience Training Education 23 Fire Door Testing and Inspection Some of the requirements for each fire door inspection and testing: Must be conducted annually with written records that are dated and signed Visually inspect doors for any damage or missing parts Operate the door fully to ensure door will close and function properly Inspect door hardware and replace all defective items Tin-clad doors must be inspected for dry rot of the wood core 24

13 Fire Door Testing and Inspection Additional requirements for each fire door inspection and testing: No holes or breaks exist in the surfaces of the door or frame Glazing and glazing beads are intact and secure Clearance between the bottom of the door and the threshold cannot exceed ¾ inch, unless the bottom of the door is mounted more than 38 inches above the floor, then the clearance is limited to 3/8 inch Check to make sure the coordinator is operating correctly 25 Fire Door Testing and Inspection Additional requirements for each fire door inspection and testing: Make sure positive latching hardware secures the door in the closed position Confirm that no field modifications have been made to the door or frame that would void the fire rating Check door and rating label to ensure it is legible, and it is the proper rating for the barrier 26

14 Fire Door Testing and Inspection A sample Fire Door Inspection form is included in your package Annual Inspection of Swinging Fire Door Assemblies Name of Property: Fire Door Assembly Location: Special Locking Arrangement?: Number of Leafs: Fire Rating of Each Leaf: Fire Rating of Frame: Rating of Barrier: Purpose of Rated Barrier: Automatic or Manual Operator?: Hold-open Device?: Inspected By: Date: Inspection Activity: Yes No N/A Comments 1. Is the door and frame free from holes and breaks in all surfaces? 2. Are all the glazing, vision light frames and glazing beads intact and securely fastened? 3. Are the doors, hinges, frame, hardware and threshold secure, aligned and in working order with no visible signs of damage? 4. Are there any missing or broken parts? 5. Is the clearance from the door edge to the frame no more than 1/8 inch? 6. Is the door undercut no more than ¾ inch? 7. Does the active door leaf completely closes when operated from the full open position? 8. Does the inactive leaf close before the active leaf when a coordinator is used? 9. Does the latching hardware operate and secure the door in the closed position? 10. Is the door assembly free from are auxiliary hardware items which could interfere with its operation? 11. Has the door been modified since it was originally installed? 12. If gasketing and edge seals are installed, have they been verified for integrity and operation? All No answers must be fully explained. Source: NFPA 80, 2010 edition Supervisor s Initial: Date: Work Order #: 27 Fire Extinguishers Fire extinguishers are often over-looked in a healthcare setting until they are needed Items can not be left unattended in front of fire extinguisher cabinets, obstructing access to them 28

15 Fire Extinguishers The new NFPA 10 will permit electronic monitoring of portable fire extinguishers, provided the system monitors these points: Extinguisher is located in its proper place Access to and visibility of extinguisher is not obstructed Pressure gauge reading is in the proper range Fullness determined by weighing Electronic monitoring eliminates monthly inspections. 29 Fire Extinguishers This is achieved by sensors in the cabinet which detects objects left unattended for more than a specified amount of time The sensor then sends a signal to the monitoring system which alerts someone to act on it The advantage to facility managers is electronic monitoring eliminates monthly inspections which means less labor cost. 30

16 Fire Extinguishers Other new requirements found in NFPA 10, include: All extinguishers must be mounted on a bracket or placed in a cabinet Where extinguishers are subject to physical damage, they must be installed with the manufacturer s strap-type bracket Extinguisher must be mounted so the operating instructions are located on the front Non-rechargeable extinguishers must be removed from service no, more than 12 years after date of manufacture 31 Fire Extinguishers Other new requirements found in NFPA 10, include: Halon type extinguishers must be limited to applications where clean agent is necessary Persons performing the annual maintenance and recharging must be certified by one of the following: Factory trained and certified Certified by an organization acceptable to the AHJ Licensed or certified by a local or state AHJ Electronic monitoring is permitted in lieu of physical monthly inspections 32

17 Fire Extinguishers Other new requirements found in NFPA 10, include: Discharge hoses on wheeled units must be coiled in such a manner to prevent kinks and allow rapid deployment Hose on wheeled type extinguishers must be completely un-coiled and examined for damage during the annual maintenance procedure 33 Fire Extinguishers Other new requirements found in NFPA 10, include: Monthly inspection procedures have changed for non-wheeled extinguishers in healthcare facilities to only require: Extinguisher is located in its designated place Access to and visibility of extinguisher is not obstructed Pressure gauge reading is in its proper place Fullness determined by weighing or hefting 34

18 Fire Extinguishers Other new requirements found in NFPA 10, include: No longer required for the monthly inspection: Confirming that the operating instructions are facing out Ensuring that the safety seals and tamper indicators are not broken or missing Examination for obvious physical damage, corrosion, leakage or clogged nozzles 35 Kitchen Hood Fire Extinguishing System Changes with NFPA 96 include: All abandoned pipe and conduits from a previous installation must be removed and holes sealed Addition of baffles plates, shelves, or any modification which obstructs the spray pattern of the nozzles are not permitted A Class K extinguisher is now required in the kitchen, within 30 feet of grease producing appliances 36

19 Kitchen Hood Fire Extinguishing System Changes with NFPA 17A include: During the owner s monthly inspection of the system, the pressure gauge of the container may be electronically monitored rather than physically monitored Service technicians must be certified Fire extinguishing systems need to be tagged noncompliant when an impairment is discovered All records must be retained for 1 year All fusible links must be replaced semiannually 37 Sprinkler System Significant changes are in store for testing and inspection of the water-based fire protection system according to the new NFPA 25 Administrative responsibilities now include: All deficiencies discovered during testing and inspection must be repaired by qualified individuals The location of shutoff valves must be identified 38

20 Sprinkler System Since NFPA 25 does not specify, you get to decide how to document the location of the sprinkler valves Can be done by marking the ceiling grid Can be done by posting signs on walls below the ceiling where the valve is located Can be done by marking their location on AutoCAD drawings and post a completed line drawing showing pipe and valve locations in your maintenance department 39 Sprinkler System And an informational sign needs to be installed on all control risers to an anti-freeze loop; dry system; pre-action system; or auxiliary control valves. Each sign must indicate: Location of area served by system Location of auxiliary drains and low-point drains for dry and pre-action systems The presence or location of anti-freeze systems The presence or location of heat tape 40

21 Sprinkler System Actual changes in the testing and inspection procedures, include: Vane and pressure type waterflow switches are permitted to be tested semi-annually (Used to be quarterly) One additional main drain test must be conducted each quarter downstream of the backflow preventer Dry sprinklers in service for 10 or more years must be replaced or a sample taken for testing 41 Sprinkler System Standpipe hose valves (not FDC) are required to be inspected quarterly for the following: Ensure hose caps are in place and not damaged Inspect hose threads for damage Ensure valve handle is present and not damaged Inspect gaskets for damage and deterioration Ensure hose valve is not leaking Ensure access to hose valve is not obstructed 42

22 Sprinkler System Standpipe systems with 2½ inch hose valves must have their valves tested annually by opening and closing the valve Standpipe systems with 1½ inch hose valves must have their valves tested every 3-years by opening and closing the valve Standpipe waterflow tests every 5 years are now only for wet standpipes. Dry standpipes are required to have hydrostatic test every 5 years 43 Fire Hose Valve Testing and Inspection A sample Fire Hose Valve Test & Inspection form is included in your package 44

23 Sprinkler System Electric motor driven fire pumps are to be tested monthly at no-flow conditions, while engine driven fire pumps are still required to be tested weekly at no-flow conditions 45 Fire Alarm Test Reports One of the most often cited findings in hospital surveys involves the fire alarm test report Not everything that was required to be tested was actually being tested, and until recently, surveyors and inspectors were not always asking to see documentation that everything was properly tested That has now changed, and AHJs are now holding organizations accountable for all testing requirements 46

24 Fire Alarm Test Reports The required information on the fire alarm test report has changed. NFPA 72 has a new name: National Fire Alarm and Signaling Code. This is to reflect the emphasis on the emergency communication system during an emergency. Changes on the test report include: A description of the property being tested The occupancy type classification of the property Name, address and contact information of the property representative Qualifications of the testing technician 47 Fire Alarm Test Reports Confirmation that there is a contract for testing and inspection of the fire alarm system Identification of the type of system or service that the alarm system provides Identification of the type of Mass Notification System used Identification of the Uninterruptible Power System (UPS) used Identification if the building is equipped with an In- Building Fire Emergency Voice Alarm Communication System Identification if building is provided with Notification Appliance Circuit (NAC) extender panels 48

25 Fire Alarm Test Reports Documentation that notification of key stakeholders was made prior to the beginning of the service Test results of devices tested (Visual Inspection / Functional Test) A separate Device Test Results sheet, identifying the following for every device tested: Device type System address Location Test results (Pass / Fail) 49 Fire Alarm Test Reports Make sure you review these changes with your fire alarm testing contractor Because the LSC surveyors will be asking to review them as soon as the 2012 edition of the Life Safety Code is finally adopted NFPA 72 has sample forms that your contractor can use The new test form is 11 pages long The current NFPA 72 test form is 4 pages long 50

26 Generator Testing NFPA 99 and NFPA 110 are the standards healthcare organizations must follow for the proper testing and inspection of the emergency power generators Changes with NFPA 110 include: The percentages listed are now considered not-less-than rather than absolute After each maintenance or repair service on the generator, an operational test must be initiated at an ATS and each ATS connected to the generator must be switched for a minimum of 30 minutes 51 Generator Testing Changes with NFPA 110 include: Paralleling gear must be subject to a testing, inspection and maintenance program that includes: Checking all electrical connections Inspection or testing for evidence of overheating and excessive contact erosion Removal of dust and dirt Replacement of contacts when required 52

27 Generator Testing Changes with NFPA 110 include: The testing, inspection and maintenance frequency for the paralleling gear is not specified in NFPA 110, but at the minimum should follow manufacturer s recommendation 53 Generator Testing Changes with NFPA 110 include: Automatic Transfer Switches (ATS) must be subject to an inspection and maintenance program that includes: Checking all electrical connections Inspection or testing for evidence of overheating and excessive contact erosion Removal of dust and dirt Replacement of contacts when required 54

28 Generator Testing Changes with NFPA 110 include: The inspection and maintenance frequency for the ATS is not specified in standard section of NFPA 110, but the Annex section recommends annual maintenance and quarterly inspections 55 Generator Testing Changes with NFPA 110 include: Battery inspections are now permitted weekly rather than at intervals of no more than 7 days Must include recording the voltage Maintenance of lead-acid batteries must include the monthly testing and recording of electrolyte specific gravity. Battery conductance testing is permitted in lieu of the testing of specific gravity when warranted 56

29 Generator Testing Changes with NFPA 110 include: Quarterly load tests on batteries are recommended in the Annex section of NFPA 110 Load tests for nameplate capacity are calculated in kw, not amps [Use kw = 3 X PF X Amps X Volts / 1000 for conversion] An annual fuel quality test must be performed in accordance with ASTM standards 57 Generator Testing Changes with NFPA 110 include: Diesel powered generators that do not meet the requirements of the monthly load test, must continue to be tested monthly and be exercised annually with supplemental loads at not less than 50 percent of the nameplate capacity (in kw) for 30 minutes, and not less than 75 percent of the nameplate capacity (in kw) for 60 minutes, for a total duration of 90 continuous minutes (used to be 2-hours) 58

30 Generator Testing Changes with NFPA 110 include: Spark ignition generators must be exercised at least once a month with the available emergency load for 30 minutes or until the water temperature and oil pressure have stabilized Generator test must be initiated by simulating a power outage using the test switches on the ATS or by opening a normal breaker (not required) 59 Generator Testing Changes with NFPA 110 include: Generators must be tested once every 36 months with a load of not less than 30 percent of the nameplate rating (in kw) for 4 continuous hours Test must be initiated by operating one ATS switch, then operate the remaining ATS test switches Supplemental load is permitted to be used in order to reach the 30 percent level [While some Accreditation Organizations already require the 3-year 4-hour load test, it is not required by CMS until the 2012 LSC is adopted] 60

31 Generator Testing Changes with NFPA 110 include: Inspection, testing and maintenance records are required to be maintained for the life of the building Electronic records are permitted The monthly load test now requires the generator to be warmed up to normal operating temperatures before the load test begins Minimum temperature of the room containing the generator (including outside gen-sets) is now 40 F 61 Results of the Polling Question Let s look at the results of the polling question: At this time, how prepared is your organization for the new 2012 edition of the Life Safety Code? 62

32 Temporary Construction Barriers The new Life Safety Code references NFPA 241 Standard for Safeguarding Construction, Alterations, and Demolition Activities, 2009 edition and this standard has made changes involving temporary construction barriers Temporary construction barriers must be erected to separate occupied egress areas of the building from those areas undergoing alterations, construction, or demolition, when such operations are considered as having a higher level of hazard than the occupied portion of the building 63 Temporary Construction Barriers The rules for temporary barriers apply in areas open to the means of egress (corridor) Temporary walls must be 1-hour fire-rated with ¾ hour fire-rated doors, if provided Non-fire-rated walls are permitted when automatic sprinkler systems are installed and operating in the construction area Non-fire-rated walls are not permitted to be constructed with tarps according to the Annex section of NFPA

33 Temporary Construction Barriers It appears that non-combustible plastic sheeting is no longer permitted for temporary construction barriers 65 Temporary Construction Barriers 1-hour fire-rated barriers will definitely be required for construction areas that are not protected with sprinklers 1-hour barriers are typically made using 3½ steel studs, and attaching 5/8 gypsum wall board to both sides of the studs, and tape and mud all joints Not an easy proposition where pipes, duct and conduit are located 66

34 Temporary Construction Barriers Where sprinklers are installed and operating in construction areas, the temporary barrier is permitted to be non-fire-rated Time will tell if non-combustible plastic sheeting will be permitted for sprinklered construction areas since tarps are not permitted CMS and the AOs will have to issue an interpretation on this issue 67 Questions & Answers Submit a question: Brad Keyes, CHSP Owner Keyes Life Safety Compliance Rockton, IL 1. Go to the Q & A box located on your screen. 2. Type in your question. 3. Click the Icon to send. 68

35 Thank you for attending! For more information on programs HCPro offers please visit Be sure to register for HCPro s next live program: Value-Based Purchasing and Documentation Improvement: Strategies for Medical Record Accuracy October 8, 2013 at 1:00pm Eastern 69 This concludes today s program. Please do not close your browser. When the presentation ends you will be automatically redirected to the post-event survey. 70

36 Elizabeth Petersen Vice President HCPro, Inc. a 90-minute webcast on September 23, 2013 Adopting the 2012 Life Safety Code : Prepare for Fire Safety Equipment Testing and Inspection Changes attended Certificate of Attendance

MAINTENANCE AND TESTING OF FIRE SPRINKLER SYSTEMS

MAINTENANCE AND TESTING OF FIRE SPRINKLER SYSTEMS MAINTENANCE AND TESTING OF FIRE SPRINKLER SYSTEMS Introduction When properly installed and maintained, automatic fire sprinkler systems have proven to be the most effective means for protecting life and

More information

Presented by: Brad Keyes, CHSP Senior Consultant Keyes Life Safety Compliance, LLC

Presented by: Brad Keyes, CHSP Senior Consultant Keyes Life Safety Compliance, LLC Presented by: Brad Keyes, CHSP Senior Consultant Keyes Life Safety Compliance, LLC Changes to Life Safety Compliance Healthcare leaders will have to deal with many changes in Life Safety compliance when

More information

Iowa State Fire Marshal

Iowa State Fire Marshal Iowa State Fire Marshal LIFE SAFETY CODE REQUIREMENTS LONG TERM CARE Kyle R. Gorsh, Special Agent in Charge Iowa Department of Public Safety State Fire Marshal Division 2012 LSC & Applicable Standards

More information

Developing a Healthcare Facility Fire Door Inspection Program

Developing a Healthcare Facility Fire Door Inspection Program Developing a Healthcare Facility Fire Door Inspection Program WELCOME Moderator: Richard Schieferdecker support.webinato.com Audio QUESTIONS How To Ask a Question: 1 POLLING There will be occasional interactive

More information

Life Safety Code NFPA 10 NFPA 13 NFPA 25 NFPA 72 NFPA 90A NFPA 110 NFPA 99 THE 2012 EDITION OF THE LIFE SAFETY CODE HOSPITAL EDITION SESSION #7

Life Safety Code NFPA 10 NFPA 13 NFPA 25 NFPA 72 NFPA 90A NFPA 110 NFPA 99 THE 2012 EDITION OF THE LIFE SAFETY CODE HOSPITAL EDITION SESSION #7 THE 2012 EDITION OF THE LIFE SAFETY CODE HOSPITAL EDITION SESSION #7 AGENDA: Life Safety Code Referenced Publications Overview Life Safety Code NFPA 10 NFPA 13 NFPA 25 NFPA 72 NFPA 90A NFPA 110 NFPA 99

More information

LIFE SAFETY COMPLIANCE: ADAPTING TO THE 2012 LIFE SAFETY CODE

LIFE SAFETY COMPLIANCE: ADAPTING TO THE 2012 LIFE SAFETY CODE California Society for Healthcare Engineering SOUTHERN CALIFORNIA SEMINAR LIFE SAFETY COMPLIANCE: ADAPTING TO THE 2012 LIFE SAFETY CODE 1 PROGRAM AGENDA Adoption of 2012 LSC CMS Final Rule / Amendments

More information

2-SUPPRESSION REQUIREMENTS - CODE REQUIRED INSPECTIONS TEST Page 1 of 7

2-SUPPRESSION REQUIREMENTS - CODE REQUIRED INSPECTIONS TEST Page 1 of 7 WET SPRINKLER Monthly Wet Sprinkler 2-SUPPRESSION REQUIREMENTS - CODE REQUIRED INSPECTIONS TEST Page 1 of 7 VISUALS [per NFPA 25-1998 ed] 1. Gauge (Ck for Condition, Normal Pressure) [per 2-2.4.1] 2. Valves

More information

2012 Life Safety and Health Care Facility Codes - Door Inspections and Other Critical Inspection, Testing and Maintenance

2012 Life Safety and Health Care Facility Codes - Door Inspections and Other Critical Inspection, Testing and Maintenance 2012 Life Safety and Health Care Facility Codes - Door Inspections and Other Critical Inspection, Testing and Maintenance Will begin at 1 pm Housekeeping Announcements Problems during the call? Press *0

More information

NFPA CODE TESTING & INSPECTION. Requirements & Recommendations for. Licensed Florida Hospitals, Ambulatory Surgery Centers,

NFPA CODE TESTING & INSPECTION. Requirements & Recommendations for. Licensed Florida Hospitals, Ambulatory Surgery Centers, NFPA CODE TESTING & INSPECTION Requirements & Recommendations for Licensed Florida Hospitals, Ambulatory Surgery Centers, ICF/IID Healthcare, & In-patient Hospice Facilities per NFPA Life Safety Code 101

More information

THE 2012 EDITION OF THE LIFE SAFETY CODE NURSING HOME EDITION SESSION #4

THE 2012 EDITION OF THE LIFE SAFETY CODE NURSING HOME EDITION SESSION #4 THE 2012 EDITION OF THE LIFE SAFETY CODE NURSING HOME EDITION SESSION #4 WELCOME Moderator: Richard Schieferdecker support.webinato.com Audio 1 QUESTIONS How To Ask a Question: POLLING There will be occasional

More information

Winnipeg Fire Department Fire Prevention Branch

Winnipeg Fire Department Fire Prevention Branch Winnipeg Fire Department Fire Prevention Branch Manitoba Fire Code Life-Safety Equipment Maintenance Requirements The Fire Prevention Branch of the Winnipeg Fire Department has prepared this document of

More information

Black Diamond Fire Department Building Owner s Responsibilities for Fire Safety Equipment

Black Diamond Fire Department Building Owner s Responsibilities for Fire Safety Equipment Black Diamond Fire Department Building Owner s Responsibilities for Fire Safety Equipment February 2017 Alberta Fire Code safety equipment maintenance requirements: The Black Diamond Fire Department has

More information

WHAT TO EXPECT DURING A FIRE DOOR INSPECTION

WHAT TO EXPECT DURING A FIRE DOOR INSPECTION WHAT TO EXPECT DURING A FIRE DOOR INSPECTION Basic Fire Door Inspections 1. Fire door basic function 2. Understanding codes 3. Responsibility of end user 4. Common fire door deficiencies 5. What your door

More information

NFPA 80 Overview January 21, 2016

NFPA 80 Overview January 21, 2016 NFPA 80 Overview January 21, 2016 Kristin Bigda, P.E. Senior Fire Protection Engineer National Fire Protection Association Presenter Kristin Bigda, P.E. Senior Fire Protection Engineer, NFPA Building Fire

More information

Today s Webcast starts at 1:00 p.m. Eastern. You will not hear audio until the Webcast begins

Today s Webcast starts at 1:00 p.m. Eastern. You will not hear audio until the Webcast begins Today s Webcast starts at 1:00 p.m. Eastern. You will not hear audio until the Webcast begins Today's Moderator Cathy Jakicic Editor Today's Presenter Esteban Cota National Business Manager for Fire Safety

More information

CMS Announcement 3/27/2017. Adoption of 2012 Life Safety Code Health Care Facilities Code. Kenneth Daily, LNHA

CMS Announcement 3/27/2017. Adoption of 2012 Life Safety Code Health Care Facilities Code. Kenneth Daily, LNHA Adoption of 2012 Life Safety Code Health Care Facilities Code Kenneth Daily, LNHA kenn@qissurvey.com CMS Announcement May 2016 Life Safety Code Health Care Code Effective July 5 th Numerous changes many

More information

Service Requirements SEMI- ANNUAL ANNUALLY OTHER REF. REQUIREMENT

Service Requirements SEMI- ANNUAL ANNUALLY OTHER REF. REQUIREMENT 58 Fire protection equipment requires care and maintenance at scheduled intervals to assure it will operate properly and safely when needed. Only personnel who are trained and qualified to maintain the

More information

FACILITY MANAGEMENT DEFICIENCIES IN ACUTE CARE SETTINGS

FACILITY MANAGEMENT DEFICIENCIES IN ACUTE CARE SETTINGS FACILITY MANAGEMENT DEFICIENCIES IN ACUTE CARE SETTINGS Presented by: Alise Howlett, Assoc. AIA,CFPE, CHFM Standards Advisor, EM/PE/LS HFAP A better healthcare survey experience 1 FREQUENT PHYSICAL ENVIRONMENT

More information

EC 5.10 FIRE PREVENTION MANAGEMENT

EC 5.10 FIRE PREVENTION MANAGEMENT EC 5.10 FIRE PREVENTION MANAGEMENT The organization manages fire safety risks. 1 The organization develops and maintains a written management plan describing the processes it implements to effectively

More information

Other EC and LS documents may be requested by surveyors, as needed, throughout the survey.

Other EC and LS documents may be requested by surveyors, as needed, throughout the survey. Documentation required by the Hospital Accreditation program Life Safety (LS) and selected Environment of Care (EC) standards is presented in the following pages. These documents will be reviewed by the

More information

System Test Report CLEAN AGENT

System Test Report CLEAN AGENT City of Black Hawk Fire Department 196 Clear Creek Street PO Box 68 Black Hawk, CO 80422-068 Office 303-582-0426 Fax 303-582-2229 www.cityofblackhawk.org System Test Report CLEAN AGENT Occupancy Information

More information

Understanding and Applying NFPA 25

Understanding and Applying NFPA 25 Understanding and Applying NFPA 25 Texas Edition Learning Objectives Describe the scope of NFPA 25. Distinguish between sprinkler system problems that fall within the scope of NFPA 25 and those that do

More information

NFPA 101 Life Safety Code Culture change 2012

NFPA 101 Life Safety Code Culture change 2012 NFPA 101 Life Safety Code Culture change 2012 Produced by Kansas Fire Marshal April, 2012 On March 9, 2012 Centers for Medicare & Medicaid Services implements a policy where they have formally adopted

More information

Center for Clinical Standards and Quality /Survey & Certification Group

Center for Clinical Standards and Quality /Survey & Certification Group DEPARTMENT OF HEALTH & HUMAN SERVICES Centers for Medicare & Medicaid Services 7500 Security Boulevard, Mail Stop C2-21-16 Baltimore, Maryland 21244-1850 Center for Clinical Standards and Quality /Survey

More information

MINOOKA FIRE PROTECTION DISTRICT Fire Prevention Bureau Fire Inspector Rodney Bradberry Plan Review

MINOOKA FIRE PROTECTION DISTRICT Fire Prevention Bureau Fire Inspector Rodney Bradberry Plan Review MINOOKA FIRE PROTECTION DISTRICT Fire Prevention Bureau Fire Inspector Rodney Bradberry Plan Review Minooka Fire Protection District Maintaining Your Fire Safety Systems Fire continues to be a major threat

More information

Medical Gas Inspections and Maintenance Programs. HESNI Annual Conference NIU Conference Center May 10-11, 2018 Presented by Mathis Carlson

Medical Gas Inspections and Maintenance Programs. HESNI Annual Conference NIU Conference Center May 10-11, 2018 Presented by Mathis Carlson Medical Gas Inspections and Maintenance Programs HESNI Annual Conference NIU Conference Center May 10-11, 2018 Presented by Mathis Carlson Mathis Carlson I have worked for the last 15+ years in the Medical

More information

New Construction Fire Inspection Process

New Construction Fire Inspection Process New Construction Fire Inspection Process This document is intended to provide the Owner, Designer, and/or Contractor of new construction with an outline of required fire inspections and with the specific

More information

1. Are there any annual sprinkler head inspection forms available? No, there are none available at this time.

1. Are there any annual sprinkler head inspection forms available? No, there are none available at this time. Sprinkler 1. Are there any annual sprinkler head inspection forms available? No, there are none available at this time. 2. Does the annual sprinkler head inspection have to be done by a licensed technician

More information

WHEA FSE inspections.

WHEA FSE inspections. WHEA FSE inspections www.jfahern.com FEC.02.03.05 Features of Fire Safety Buildings are protected from fire by a series of detection, notification and suppression devices Each feature of fire safety must

More information

1-300 Fire and/or Smoke Dampers to Inspect $ Fire and/or Smoke Dampers to Inspect $34.30

1-300 Fire and/or Smoke Dampers to Inspect $ Fire and/or Smoke Dampers to Inspect $34.30 Life Safety Services, LLC TXMAS Schedule Contract Number: TXMAS-12-03FAC030 Passive Fire Protection Services Authorized Federal Supply Schedule Price List Quantity of Dampers to Inspect Per Damper to Survey

More information

Swinging Egress and Fire Doors

Swinging Egress and Fire Doors Presented by: AHCA Seminar: Inspecting and Maintaining Swinging Egress and Fire Doors Current State CMS Memorandum July 28, 2017 Tuesday May, 3, 2016 CMS issued the final rule adopting the 2012 Life Safety

More information

Model Policy On Portable Fire Extinguishers (Ontario Version)

Model Policy On Portable Fire Extinguishers (Ontario Version) Model Policy On Portable Fire Extinguishers (Ontario Version) Every workplace needs a policy ensuring the appropriate selection, use, storage and maintenance of fire extinguishers. OHS managers in any

More information

INSPECTOR I SKILLS ADMINISTRATION

INSPECTOR I SKILLS ADMINISTRATION INSPECTOR I SKILLS ADMINISTRATION 1- Prepare inspection reports so that the report is clear and concise and reflects the findings of the inspection in accordance with the applicable codes and standards..

More information

First Aspen Federal Regulation Set: K LSC 2000 Health Existing

First Aspen Federal Regulation Set: K LSC 2000 Health Existing First Aspen Federal Regulation Set: K 01.01 LSC 2000 Health Existing K 0000 Title CFR Type INITIAL COMMENTS Memo K 0011 If the building has a common wall with a nonconforming building, the common wall

More information

FACILITY MANAGEMENT DEFICIENCIES IN CRITICAL ACCESS HOSPITALS (CAH)

FACILITY MANAGEMENT DEFICIENCIES IN CRITICAL ACCESS HOSPITALS (CAH) FACILITY MANAGEMENT DEFICIENCIES IN CRITICAL ACCESS HOSPITALS (CAH) Presented by: Alise Howlett, Assoc. AIA, CFPE, CHFM Standards Advisor, EM/PE/LS HFAP A better healthcare survey experience 1 FREQUENT

More information

International Fire Code 2006 Requirements for Construction Plan Reviews of Commercial and Multi-Family Structures

International Fire Code 2006 Requirements for Construction Plan Reviews of Commercial and Multi-Family Structures International Fire Code 2006 Requirements for Construction Plan Reviews of Commercial and Multi-Family Structures Please note this is not an all-inclusive list. The type and complexity of your project

More information

Osceola County Department of Fire Rescue and Emergency Medical Services

Osceola County Department of Fire Rescue and Emergency Medical Services St. Number Dir Street Name Street Type Inspected Time of Day to be Re-inspected Zip Code Occupancy Type Emergency Contact Phone (Inc. Area Code) Building Owner Building Owner Mailing Address Bldg. Owner

More information

UNIVERSITY OF ROCHESTER ENVIRONMENTAL HEALTH & SAFETY

UNIVERSITY OF ROCHESTER ENVIRONMENTAL HEALTH & SAFETY Revision No.: 11 Page 1 of 12 I. PURPOSE This procedure establishes a tool to help maintain a safe environment for all patients, visitors and staff by evaluating the loss of a life safety feature during

More information

Field Guide for Healthcare Facilities

Field Guide for Healthcare Facilities Field Guide for Healthcare Facilities Jennifer L. Frecker James K. Lathrop Written by industry experts Jennifer L. Frecker and James K. Lathrop and using an easy-to-digest format, The New Life Safety Code

More information

2016 Joint Commission Update

2016 Joint Commission Update 2016 Joint Commission Update Bert M. Gumeringer, MBA, CHFM, FASHE Asst. Vice President-Facilities Operations Texas Children s Hospital August 12, 2016 11:30am-12:30pm Top 10 Findings Comparison-2015 vs.2016

More information

Safety Tips for the Office

Safety Tips for the Office Safety Tips for the Office An office fire can be devastating - resulting in business interruption or permanent closure, loss of lives, jobs, property and information. Offices are loaded with combustible

More information

Builders Risk - Fire Prevention Inspection Checklist

Builders Risk - Fire Prevention Inspection Checklist Builders Risk - Fire Prevention Inspection Checklist Use our inspection checklist tool to help you identify and monitor risk related to builders risk of fire on the job site. Inspection Details: Inspector

More information

Annual Water-Based Fire Protection Systems Inspection

Annual Water-Based Fire Protection Systems Inspection Annual Water-Based Fire Protection Systems Inspection 2425 Amann Drive Belleville, IL 62220 www.boyerfire.com Phone: 618-222-1500 Fax: 618-222-1502 Inspector: Steve Love Inspection date: 04/03/17 Inspection

More information

Florida Building Code Chapter 9 Fire Protection Systems Advanced Course

Florida Building Code Chapter 9 Fire Protection Systems Advanced Course Florida Building Code 2010 Chapter 9 Fire Protection Systems Advanced Course 1 Introduction This course will cover specific sections of Chapter 9 that relate to fire alarm systems. While many contractors

More information

Skilled Healthcare Documentation Requirements Life Safety and Fire Protection

Skilled Healthcare Documentation Requirements Life Safety and Fire Protection DATE OF EVALUATION: FACILITY NAME: FACILITY ADDRESS: ADMINISTRATOR: MAINTENANCE DIRECTOR: All required documentation must be written and saved for at least 2 years and some documentation may be required

More information

Department of Health Life Safety Code Update

Department of Health Life Safety Code Update Department of Health Life Safety Code Update Presented by: Charlie Schlegel, Director Division of Safety Inspection Overview CMS Adoption of the 2012 Life Safety Code (LSC) and 2012 Health Care Facilities

More information

Measures (ILSM) Process

Measures (ILSM) Process Managing the Interim Life Safety Measures (ILSM) Process 1 A Program for The Texas Association of Healthcare Facility Management Monday, April 30, 2012 Robert H. Bartels, CHFM CHSP CHEP SASHE President,

More information

Fire and Smoke Door Inspections Qualified Training 02/03/17

Fire and Smoke Door Inspections Qualified Training 02/03/17 Fire and Smoke Door Inspections Qualified Training 02/03/17 Basis of Requirements NFPA 101 requires annual fire and smoke door inspections (Section 18/19.2.2.2.1) Sections 18/19.2.2.1 require compliance

More information

Global Property. SEMIANNUAL FIRE PROTECTION EQUIPMENT INSPECTION REPORT Date of Inspection Location:

Global Property. SEMIANNUAL FIRE PROTECTION EQUIPMENT INSPECTION REPORT Date of Inspection Location: Global Property SEMIANNUAL FIRE PROTECTION EQUIPMENT INSPECTION REPORT Plant: Date of Inspection Location: Inspected By: Reviewed By CONTROL VALVES (If Valves are Not Locked Open or Electronically Supervised

More information

June 2018 Safety Meeting Fire Extinguishers Part I

June 2018 Safety Meeting Fire Extinguishers Part I June 2018 Safety Meeting Fire Extinguishers Part I The portable fire extinguisher, one of the most common fire protection appliances in use today, is found in fixed facilities and on propane vehicles.

More information

Agency for Health Care Administration

Agency for Health Care Administration Page 1 of 92 ST - K0000 - INITIAL COMMENTS Title INITIAL COMMENTS Type Memo Tag These guidelines are meant solely to provide guidance to surveyors in the survey process. ST - K0100 - General Requirements

More information

Danilo B. Concepcion, CBNT, CCHT-A Operations Manager St. Joseph Hospital Renal Services

Danilo B. Concepcion, CBNT, CCHT-A Operations Manager St. Joseph Hospital Renal Services Life Safety Code Danilo B. Concepcion, CBNT, CCHT-A Operations Manager St. Joseph Hospital Renal Services danilo.concepcion@stjoe.org 714-771-8944 The findings and conclusions in this presentation are

More information

UNIVERSITY OF ROCHESTER ENVIRONMENTAL HEALTH & SAFETY

UNIVERSITY OF ROCHESTER ENVIRONMENTAL HEALTH & SAFETY Revision No.: 6 Page 1 of 5 I. PURPOSE This procedure provides guidance to EH&S office staff to coordinate notifications of appropriate internal staff who will need to respond to an unannounced Joint Commission

More information

Agency for Health Care Administration

Agency for Health Care Administration Page 1 of 34 ST - K0000 - INITIAL COMMENTS Title INITIAL COMMENTS Statute or Rule Type Memo Tag These guidelines are meant solely to provide guidance to surveyors in the survey process. ST - K0001 - OTHER

More information

NFPA 96, 2017 REVIEW SUMMARY

NFPA 96, 2017 REVIEW SUMMARY NFPA 96, 2017 REVIEW SUMMARY 1) NFPA 96 REVISION SUMMARY NFPA 96 Standard for Ventilation Control and Fire Protection of Commercial Cooking Operations The 2017 edition adds a new normative annex on mobile

More information

New DATE OF BLDG. PERMIT OR PLAN APPROVAL: SURVEYOR (SIGNATURE) TITLE OFFICE DATE REVIEW AUTHORITY OFFICIAL (SIGNATURE) TITLE OFFICE DATE

New DATE OF BLDG. PERMIT OR PLAN APPROVAL: SURVEYOR (SIGNATURE) TITLE OFFICE DATE REVIEW AUTHORITY OFFICIAL (SIGNATURE) TITLE OFFICE DATE DEPARTMENT OF HEALTH & HUMAN SERVICES CENTERS FOR MEDICARE & MEDICAID SERVICES FIRE SAFETY SURVEY REPORT - AMBULATORY SURGICAL CENTERS Medicare 1. (A) PROVIDER NUMBER Identifying information as shown in

More information

*** Inspection *** Please identify yourself as a Cintas representative when arriving onsite.

*** Inspection *** Please identify yourself as a Cintas representative when arriving onsite. Tech Clock-In/Out IVR: 1-877-349-2906 Job #: Tech ID #: 2902 FP Service Instructions Job #: *** Inspection *** You must clock in and out of this job through Cintas's IVR phone system! Call 1-877-349-2906

More information

Oxnard Fire Department 360 W. Second Street Oxnard, CA (805) Fax (805)

Oxnard Fire Department 360 W. Second Street Oxnard, CA (805) Fax (805) Oxnard Fire Department 360 W. Second Street Oxnard, CA 93030 (805) 385-7722 Fax (805) 385-8009 FIVE YEAR CERTIFICATION REPORT Service and maintenance report for automatic fire extinguishing systems, including

More information

NFPA 101, 2012 EDITION IMPACT ON NEW AND EXISTING HEALTH CARE FACILITIES

NFPA 101, 2012 EDITION IMPACT ON NEW AND EXISTING HEALTH CARE FACILITIES NFPA 101, 2012 EDITION IMPACT ON NEW AND EXISTING HEALTH CARE FACILITIES Sharon S. Gilyeat, P.E., Principal Koffel Associates, Inc. www.koffel.com sgilyeat@koffel.com Expertly Engineering Safety From Fire

More information

NFPA 25 and the Influence of Liability

NFPA 25 and the Influence of Liability NFPA 25 and the Influence of Liability NFPA 25 Summit Addison, IL Northern Illinois Fire Sprinkler Advisory Board/ Illinois Fire Inspectors Association Date: Speaker: July 28, 2017 Michael J Bosma Meet

More information

Are there any policies regarding outlets that contain USB ports?

Are there any policies regarding outlets that contain USB ports? Answers to the Questions Mark J. Blackburn, P.E., CFPS February, 2016 Question 1 Are there any policies regarding outlets that contain USB ports? There is no direct reference in code about these types

More information

ALARM SYSTEMS AND EVACUATION PLANS SELF INSPECTION CHECKLIST

ALARM SYSTEMS AND EVACUATION PLANS SELF INSPECTION CHECKLIST OPTIONAL INFORMATION Name of School: Date of Inspection: Vocational Program/Course/Room: Signature of Inspector: ALARM SYSTEMS AND EVACUATION PLANS Guidelines: This checklist covers regulations issued

More information

GUILFORD COUNTY SCHOOLS

GUILFORD COUNTY SCHOOLS GUILFORD COUNTY SCHOOLS Fire Extinguisher Plan Policy In accordance with the regulations established by the United States Department of Labor pursuant to the Occupational Safety and Health Act and the

More information

Changes to the 2018 Joint Commission Comprehensive Accreditation Manual for Hospitals (CAMH)

Changes to the 2018 Joint Commission Comprehensive Accreditation Manual for Hospitals (CAMH) Changes to the 2018 Joint Commission Comprehensive Accreditation Manual for Hospitals (CAMH) The following represents a review of the Life Safety chapter of the new 2018 Joint Commission CAMH manual for

More information

Facilities Management

Facilities Management Facilities Management Policy Number: 700.4 Title: Fire Protection & Life Safety Inspection Policy Implementation Date: August 1 st, 2008 Last Revised: September 14 th, 2017 Last Audited: August, 2017 Introduction

More information

Fire Rated Door Assemblies: Compliant Designs

Fire Rated Door Assemblies: Compliant Designs Fire Rated Door Assemblies: Compliant Designs Steel Door Institute www.steeldoor.org AIA Provider #G389 Course #: SDIFIRE 1 HSW CE hour 1 Credit(s) earned on completion of this course will be reported

More information

David Stymiest, PE, CHFM, CHSP, FASHE cell Copyright 2014, Smith Seckman Reid, Inc.; All rights reserved

David Stymiest, PE, CHFM, CHSP, FASHE cell Copyright 2014, Smith Seckman Reid, Inc.; All rights reserved AHCA 2014 Fall Conference Changes in Emergency Power Codes & Standards David Stymiest, PE, CHFM, CHSP, FASHE DStymiest@ssr-inc.com, cell 504.232.1113 Copyright 2014, Smith Seckman Reid, Inc.; All rights

More information

THE HEALTHCARE ENVIRONMENT UPDATE. Anne M. Guglielmo, Engineer Engineering Department The Joint Commission. Copyright, The Joint Commission

THE HEALTHCARE ENVIRONMENT UPDATE. Anne M. Guglielmo, Engineer Engineering Department The Joint Commission. Copyright, The Joint Commission 2013 THE HEALTHCARE ENVIRONMENT UPDATE Anne M. Guglielmo, Engineer Engineering Department The Joint Commission Standard/NPSG 2012 Non Compliance 2013 Non Compliance (1 st Six Months) RC.01.01.01 61% 55%

More information

LIFE SAFETY & FIRE PREVENTION MANAGEMENT PLAN

LIFE SAFETY & FIRE PREVENTION MANAGEMENT PLAN Title/Description: Life Safety & Fire Prevention Management Department: Facilities Management Personnel: All Effective Date: 5/97 Revised: 7/00, 7/01, 7/02, 7/03, 7/04, 7/05, 7/08 LIFE SAFETY & FIRE PREVENTION

More information

Koffel Associates, Inc.

Koffel Associates, Inc. NFPA 25: STANDARD FOR THE INSPECTION, TESTING, AND MAINTENANCE OF WATER BASED FIRE PROTECTION SYSTEMS William E. Koffel, P.E., FSFPE President Koffel Associates, Inc. www.koffel.com wkoffel@koffel.com

More information

Agency for Health Care Administration. Eddie Alday Life Safety Code Lead 30 th AHCA Seminar 23 September 2014

Agency for Health Care Administration. Eddie Alday Life Safety Code Lead 30 th AHCA Seminar 23 September 2014 Agency for Health Care Administration Eddie Alday Life Safety Code Lead 30 th AHCA Seminar 23 September 2014 CMS S&C Letter Interpretation CMS- S&C: 13-58-LSC Dated: 08/30/2013 Several Categorical LSC

More information

False Sense of Security???

False Sense of Security??? IS YOUR SPRINKLER SYSTEM GIVING YOU A FALSE SENSE OF SECURITY? Best Practices in Fire Safety An ASSE Virtual Symposium March 1 & 2, 2011 Walter S. Beattie CSP, CFPS, CSHM False Sense of Security??? Fire

More information

Chapter 4: Fire Protection Systems

Chapter 4: Fire Protection Systems Chapter 4: Fire Protection Systems Automatic Extinguishing Systems (Fire Sprinklers) One of the most important aspects of a storage warehouse inspection is ensuring that the automatic extinguishing system

More information

FIRE SAFETY AND PREVENTION POLICY

FIRE SAFETY AND PREVENTION POLICY Effective Date: July 26, 2011 Supersedes /Amends: VRS-49/April 2006 Originating Office: Office of the Vice-President, Services Policy Number: VPS-49 PREAMBLE Concordia University (the University ) has

More information

Changes in NFPA

Changes in NFPA Changes in NFPA 72-2002 2002 Oregon Fire Code Committee November 25, 2003 Michael B. Baker, SET Automatic Fire Alarm Association MikeBaker@afaa.org 2003 Michael B. Baker 1 Table of Contents 1. Administration

More information

Quick Guide for Fire Sprinkler Inspection Requirements Key Deficiencies with NFPA References NFPA & NFPA 13/

Quick Guide for Fire Sprinkler Inspection Requirements Key Deficiencies with NFPA References NFPA & NFPA 13/ Quick Guide for Fire Sprinkler Inspection Requirements Key Deficiencies with NFPA References NFPA 25 2017 & NFPA 13/72 2016 The purpose of this guide is to help you determine if the system will work as

More information

About the Instructor & Presenter:

About the Instructor & Presenter: About the Instructor & Presenter: Paul G. Baillargeon, AHC, FDAI Vice President, Technical Consulting Door Security & Safety Foundation A noted veteran in the door and hardware industry, Mr. Baillargeon

More information

Title: BFST1505 Syllabus

Title: BFST1505 Syllabus DEPARTMENT OF FINANCIAL SERVICES Division of State Fire Marshal Bureau of Fire Standards and Training Title: BFST1505 Syllabus Revision: April 5, 2018 Section I - Course Information Course Title: Fire

More information

Florida Building Code 2010

Florida Building Code 2010 Introduction Florida Building Code 2010 Chapter 9 Fire Protection Systems This course will cover specific sections of Chapter 9 that relate to fire alarm systems. While many contractors are familiar with

More information

I. Scope: II. Environmental Health and Safety Fire Alarm System Impairment Program - Guideline Revision Date: April, 2018

I. Scope: II. Environmental Health and Safety Fire Alarm System Impairment Program - Guideline Revision Date: April, 2018 Environmental Health and Safety Fire Alarm System Impairment Program - Guideline Revision Date: April, 2018 Prepared by: EH&S The probability of casualties and major structural damage increases when fire

More information

Life Safety Code Comparison

Life Safety Code Comparison ASHE Monograph Life Safety Code Comparison Michael A. Crowley, PE, SASHE Jeffery E. Harper, PE ASHE Monograph Life Safety Code Comparison Michael A. Crowley, PE, SASHE Jeffery E. Harper, PE Chicago 2013

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-21 21 03.00 10 February 2009) ---------------------------------- Preparing Activity: USACE Superseding UFGS-21 21 03.00 10 (April 2006) UNIFIED FACILITIES GUIDE SPECIFICATIONS

More information

FHCA 2014 Annual Conference & Trade Show

FHCA 2014 Annual Conference & Trade Show FHCA 2014 Annual Conference & Trade Show CE Session #5 Preparing for the Upcoming Code Changes Don t Look Back Tuesday, July 8 8:15 to 9:15 a.m. Canary 3 Operations/Quality Improvement Upon completion

More information

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU INSPECTION CHECKLIST

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU INSPECTION CHECKLIST July 1, 2010 SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU INSPECTION CHECKLIST FIRE AND LIFE SAFETY SYSTEMS FOR STRUCTURES FIVE OR MORE STORIES IN HEIGHT AND LESS THAN 75 FEET IN HEIGHT FROM THE POINT

More information

Inspection and Testing of Water-Based Systems

Inspection and Testing of Water-Based Systems Inspection and Testing of Water-Based Systems Standard Model/Computer-Based Testing Level II Content Outline The candidate for NICET certification at Level II in the Inspection and Testing of Water- Based

More information

NITROGEN-GENERATING SPRINKLER CORROSION INHIBITING SYSTEM

NITROGEN-GENERATING SPRINKLER CORROSION INHIBITING SYSTEM NITROGEN-GENERATING SPRINKLER CORROSION INHIBITING SYSTEM PART 1 - GENERAL 1.1 SUMMARY A. This section outlines the requirements for the nitrogen-generating sprinkler corrosion inhibiting system. The work

More information

Manufacturing safety solutions

Manufacturing safety solutions Manufacturing safety solutions 4 th Quarter 2011 Inside this issue Manufacturing property conservation and protection Manufacturing property conservation and protection by Robert Mauerman Upcoming events

More information

Fire Protection System Contractors and Systems. Submission of the Application for a Water-Based Fire Protection Inspector

Fire Protection System Contractors and Systems. Submission of the Application for a Water-Based Fire Protection Inspector NOTICE OF PROPOSED RULE DEVELOPMENT DEPARTMENT OF FINANCIAL SERVICES DIVISION OF STATE FIRE MARSHAL RULE CHAPTER: 69A-46, F.A.C. RULE: 69A-46.0165, F.A.C. RULE CHAPTER TITLE: Fire Protection System Contractors

More information

S a n F r a n c i s c o F i r e D e p a r t m e n t B u r e a u o f F i r e P r e v e n t i o n & I n v e s t i g a t i o n 1 of 8 P a g e

S a n F r a n c i s c o F i r e D e p a r t m e n t B u r e a u o f F i r e P r e v e n t i o n & I n v e s t i g a t i o n 1 of 8 P a g e 5.07 Air Replenishment Systems (2016) Reference: SFFC, Section 511.2. Purpose: The purpose of this bulletin is to describe the requirements for air replenishment systems intended to be used to fill firefighters'

More information

Agency for Health Care Administration

Agency for Health Care Administration Page 1 of 21 ST - K0000 - INITIAL COMMENTS Title INITIAL COMMENTS Statute or Rule Type Memo Tag These guidelines are meant solely to provide guidance to surveyors in the survey process. ST - K0300 - Other

More information

PRINTED: 06/09/2017 FORM APPROVED CENTERS FOR MEDICARE & MEDICAID SERVICES OMB NO (X2) MULTIPLE CONSTRUCTION A. BUILDING 03 - A BUILDING

PRINTED: 06/09/2017 FORM APPROVED CENTERS FOR MEDICARE & MEDICAID SERVICES OMB NO (X2) MULTIPLE CONSTRUCTION A. BUILDING 03 - A BUILDING SUMMARY PROVER'S PLAN OF CORRECTION K 000 INITIAL COMMENTS K 000 A Life Safety Code Survey was conducted by the State Fire Marshal beginning on May 9th, 2017 and ending on May 10th, 2017. Adair Acute Care

More information

STATE FIRE MARSHAL S REQUIRED FIRE PROTECTION SYSTEMS NARRATIVE REPORT

STATE FIRE MARSHAL S REQUIRED FIRE PROTECTION SYSTEMS NARRATIVE REPORT STATE FIRE MARSHAL S REQUIRED FIRE PROTECTION SYSTEMS NARRATIVE REPORT The interaction of fire protection systems can be extremely complex. The detection of a fire in a building by an automatic device

More information

5.07 Air Replenishment Systems

5.07 Air Replenishment Systems 5.07 Air Replenishment Systems Reference: 2010 SFFC, Section 511.2 Definitions: CERTIFIED COMPRESSOR. A compressor used by a contractor for maintenance and testing of air replenishment systems that is

More information

NFPA Fire Inspector I Study Guide

NFPA Fire Inspector I Study Guide NFPA 1031-2003 Fire Inspector I Study Guide National Certification Program October 2004 This document is provided This document at no cost is provided to the user at no by cost Kansas to the user Fire

More information

SERVICE MANUAL (v1) UL / ULC. WET CHEMICAL HAND PORTABLE RESTAURANT KITCHEN FIRE EXTINGUISHERS Model: SF-6LK / WBDL-6LK

SERVICE MANUAL (v1) UL / ULC. WET CHEMICAL HAND PORTABLE RESTAURANT KITCHEN FIRE EXTINGUISHERS Model: SF-6LK / WBDL-6LK STRIKE FIRST CORPORATION AKC SERVICE MANUAL (v1) UL / ULC WET CHEMICAL HAND PORTABLE RESTAURANT KITCHEN FIRE EXTINGUISHERS Model: SF-6LK / WBDL-6LK All fire extinguishers should be installed, inspected

More information

FIRE SAFETY INSPECTION REPORT

FIRE SAFETY INSPECTION REPORT FIRE SAFETY INSPECTION REPORT DANNY'S KNITWEAR LTD. ACCORD ID: 12228 SURABARI, GAZIPUR, SADAR, GAZIPUR Other Factories: ne October 17, 2015 Page 2 Fire Safety Inspection Report Introduction manufacturing

More information

The Impact the Reference Standards in the 2012 Edition of NFPA 101 have on the Operation of Health Care Facilities: NFPA 80 and 99

The Impact the Reference Standards in the 2012 Edition of NFPA 101 have on the Operation of Health Care Facilities: NFPA 80 and 99 The Impact the Reference Standards in the 2012 Edition of NFPA 101 have on the Operation of Health Care Facilities: NFPA 80 and 99 Sharon S. Gilyeat, P.E. Lauren Schrumpf August 8, 2018 Expertly Engineering

More information

A. AMERICAN ARCHITECTURAL MANUFACTURERS ASSOCIATION (AAMA) 101: Appendix Dissimilar Materials.

A. AMERICAN ARCHITECTURAL MANUFACTURERS ASSOCIATION (AAMA) 101: Appendix Dissimilar Materials. B B11.0 DIVISION 08 - OPENINGS SECTION 08 17 00 INTEGRATED DOOR OPENING ASSEMBLIES Specifier Note: Coordinate and edit articles and paragraphs below to suit project requirements. Add section numbers and

More information

ASHE Advocacy Team. Q4 ASHE Advocacy Liaison Webinar 12/7/16 12/7/16. Tim Adams, FASHE, CHFM, CHC Director of Leadership Development

ASHE Advocacy Team. Q4 ASHE Advocacy Liaison Webinar 12/7/16 12/7/16. Tim Adams, FASHE, CHFM, CHC Director of Leadership Development Q4 ASHE Advocacy Liaison Webinar 12/7/16 ASHE Advocacy Team Chad E. Beebe, AIA, CHFM, CFPS, CBO, SASHE Deputy Executive Director of Advocacy cbeebe@aha.org Tim Adams, FASHE, CHFM, CHC Director of Leadership

More information

Minimum Standards for Engineers Practicing Fire Protection Engineering in the State of Oklahoma September 14, 2016

Minimum Standards for Engineers Practicing Fire Protection Engineering in the State of Oklahoma September 14, 2016 1. Introduction The intent of this document is to establish minimum standards for the practice of fire protection engineering within the State of Oklahoma as conducted by licensed professional engineers.

More information