Manual No: Revision: G. Sensor Products. Application Guide

Size: px
Start display at page:

Download "Manual No: Revision: G. Sensor Products. Application Guide"

Transcription

1 Manual No: Revision: G Sensor Products Application Guide

2 Notice Veeder-Root makes no warranty of any kind with regard to this publication, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. Veeder-Root shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this publication. Veeder-Root reserves the right to change system options or features, or the information contained in this publication. This publication contains proprietary information which is protected by copyright. All rights reserved. No part of this publication may be photocopied, reproduced, or translated to another language without the prior written consent of Veeder-Root. DAMAGE CLAIMS 1. Thoroughly examine all components and units as soon as they are received. If damaged, write a complete and detailed description of the damage on the face of the freight bill. The carrier's agent must verify the inspection and sign the description. 2. Immediately notify the delivering carrier of damage or loss. This notification may be given either in person or by telephone. Written confirmation must be mailed within 48 hours. Railroads and motor carriers are reluctant to make adjustments for damaged merchandise unless inspected and reported promptly. 3. Risk of loss, or damage to merchandise remains with the buyer. It is the buyer's responsibility to file a claim with the carrier involved. RETURN SHIPPING For the parts return procedure, please follow the appropriate instructions in the "General Returned Goods Policy" and "Parts Return" pages in the "Policies and Literature" section of the Veeder-Root North American Environmental Products price list. Veeder-Root All rights reserved.

3 Table of Contents Table of Contents Discriminating Dispenser Pan and Containment Sump Sensors Installation Accessories Servicing Discriminating Dispenser Pan and Containment Sump Sensors When replacing Dispenser Filters or servicing Dispensers... 3 When Sensor is in alarm due to a spill or leak in the containment area... 3 Non-Discriminating Solid-State Dispenser Pan and Containment Sump Sensors Compatible Consoles Installation Accessories Sump Sensor Sensor/Cable Length Configurations Mag Sump Sensor Sensor Models and Accessories Position-Sensitive Sensor Sensor/Cable Length Configurations Stand-Alone Dispenser Pan Sensors Installation Accessories Discriminating Interstitial Sensor for Double-Wall Fiberglass Tanks Console Compatibility Sensor/Cable Length Configuration i

4 Table of Contents Interstitial Sensors for Fiberglass Tanks Sensor/Cable Length Configurations Interstitial Sensors for Steel Tanks Sensor/Cable Length Configurations...11 Accessories MicroSensor Compatible Consoles Sensor/Cable Length Configuration...12 Accessories Hydrostatic Reservoir Sensor Sensor Configuration Single-Point Mini Hydrostatic Sensor for Double Wall Sumps Sensor and Installation Kit Vapor Sensor Sensor Configuration...15 Accessories Groundwater Sensor Sensor Configurations ii

5 Table of Contents Figures Figures Fig. 1 Typical Containment Sump Sensor Installation... 2 Fig. 2 Typical Sump Sensor Installation... 5 Fig. 3 Typical Mag Sump Sensor Installation in Containment Sump... 6 Fig. 4 Typical Position-Sensitive Sensor Installation... 7 Fig. 5 Typical Interstitial Sensor Install - Fiberglass UST... 8 Fig. 6 Typical Interstitial Sensor Installation - Steel UST... 9 Fig. 7 Typical Interstitial MicroSensor Installation - Steel UST Fig. 8 Typical Interstitial MicroSensor Installation - Steel UST Fig. 9 Typical MicroSensor Installation in Riser Containment - Steel UST Fig. 10 Typical Hydrostatic Dual-Point Sensor Installation Fig. 11 Typical Single-Point Mini Hydrostatic Sensor Installation Fig. 12 Typical Vapor Sensor Installation Fig. 13 Typical Groundwater Sensor Installation iii

6 Discriminating Dispenser Pan and Containment Sump Sensors The appropriate sensor can be installed in a dispenser pan or in a containment sump and will detect the presence of, and differentiate between, hydrocarbons and other liquids. Two types of sensors are available (standard and solid state). See table for sensor features and console compatibility: Sensor Type Measurement Standard Solid-State Fluid height Float-triggered switches Ultrasonic sensing at trip points (no moving parts) Hydrocarbon/fluid differentiation method Conductive elastomer Conductive elastomer Operating temperature: 0 to +70 C -40 to +70 C Compatible consoles Console software version compatibility Maximum number of sensors monitored per console TLS-350R, TLS-350Plus, PC-350R, PC- 350Plus, TLS-350J, TLS-300i, PC-300i, and TLS-300C, i, J and PC kits Version 8 and later Interstitial - Form Number (not required for 300 series consoles) TLS-350 Series Consoles (except TLS-350J) - 8 per Interstitial Module (64 max.); TLS-350J - 3 max. TLS-300 Series Consoles - 8 max. TLS-350R, TLS-350Plus, PC-350R, and PC-350Plus Version 2 and later Type B Interface Module - Form Number per Type B Module (48 max.) Dispenser Pan Sensor - Form Number Containment Sump Sensor - Form Number Fuel at any height on the sensor, even when floating on other liquids, triggers a Fuel Alarm. Liquid Warning is triggered when liquid reaches a nominal height of 1 inch on both Dispenser Pan and Containment Sump sensors. High Liquid Alarm is triggered when liquid reaches a nominal height of 8 inches on Dispenser Pan or 10 inches on Containment Sump sensors. An open sensor triggers a Sensor Out alarm. 1

7 Operating temperature range: see table. Storage temperature range: -40 to +70 C. Standard cable length: 12 feet. Dispenser Pan Sensor dimensions: 11.6 high, 2.2 diameter. Containment Sump Sensor dimensions: 22.1 high, 2.2 diameter. Unleaded gasoline Diesel Leaded gasoline Kerosene 5% methanol/95% unleaded Jet fuel 15% ethanol/85% unleaded Aviation gasoline Installation Accessories Universal Sensor Mounting Kit, P/N , contains mounting brackets and screws. 20-foot cable (optional): - P/N for Solid-State Sensor - P/N for Standard Sensor Visit our website at for more information on Veeder-Root products and services. Submersible pump Containment sump sensor* Cord grip Weatherproof junction box with 1/2-inch N.P.T. threads (16 cubic inch volume minimum) Containment sump Seal-off IMPORTANT! DO NOT MOUNT SENSOR TO FLEXIBLE PRODUCT LINE. Rubber grommet seal clamped on inside - or as recommended by sump manufacturer 1/2'' Rigid conduit to console Product line *Containment sump sensor should: 1. Rest in the lowest point of sump. 2. Be positioned as close to outer wall as possible. 3. Be mounted in a true vertical position. Brackets, clamp, etc., from Universal sensor mounting kit sensors\cssinst.eps Fig. 1 Typical Containment Sump Sensor Installation 2

8 Servicing Discriminating Dispenser Pan and Containment Sump Sensors This procedure applies to Discriminating Dispenser Pan and Containment Sump Sensors having Form Numbers , -322, -350, -352, -360, -361, and When replacing Dispenser Filters or servicing Dispensers The sensor should be removed from the dispenser pan before replacing the filters. All fuel must be cleaned up in the dispenser pan prior to reinstalling the sensor. If the sensor is exposed to fuel during the filter replacement, the sensor may go into a fuel alarm. If this occurs the sensor must be removed from the dispenser pan and the sensor allowed to dry in a well ventilated area for up to 7 days. The recovery time will depend on how long the sensor was exposed to the fuel. If the sensor has been exposed to diesel fuel or kerosene, it will be necessary to first soak the sensor in Coleman fuel for 30 minutes and then set aside to dry in a well ventilated area for up to 7 days. It is advisable that the affected sensor be replaced and taken to a location where the soaking and recovery process can be safely performed. The recovery time will depend on how long sensor was exposed to the diesel fuel or kerosene. When Sensor is in alarm due to a spill or leak in the containment area Remove the sensor from the containment area upon arrival at the location. Dry off the sensor and allow it to recover in a well ventilated area for up to 7 days. The recovery time will depend on how long the sensor was exposed to the fuel. The sensor can be reinstalled in the containment area once the sensor has recovered and the source of the leak repaired. The containment area must be free of fuel. If the sensor has been exposed to diesel fuel or kerosene, it will be necessary to first soak the sensor in Coleman fuel for 30 minutes and then set aside to dry in a well ventilated area for up to 7 days. It is advisable that the affected sensor be replaced and taken to a location where the soaking and recovery process can be safely performed. The recovery time will depend on how long sensor was exposed to the diesel fuel or kerosene. 3

9 Non-Discriminating Solid-State Dispenser Pan and Containment Sump Sensors The appropriate sensor can be installed in a Dispenser Pan (Form Number ) or in a Containment Sump ( ) and will detect the presence of a liquid. Ultrasonic liquid level sensing technology means no moving parts and a lower temperature operating limit. Fuel alarm is triggered when liquid reaches a nominal height of 1-inch on both Dispenser Pan and Containment Sump sensors. An open sensor triggers a Sensor Out alarm. Operating temperature range: -40 to +70 C. Storage temperature range: -40 to +70 C. Standard cable length: 12 feet. Dispenser Pan Sensor dimensions: 11.6 high, 2.2 diameter. Containment Sump Sensor dimensions: 22.1 high, 2.2 diameter. Compatible Consoles TLS-350Plus, PC-350Plus, TLS-350R, PC-350R, TLS-350J Consoles TLS-350 Series Consoles (except TLS-350J) - Type A Interface Module (Form Number ) accepts up to 8 sensors (a maximum of 64 sensors could be monitored by a console). TLS-350J Console - 3 sensors max. Version 2 or later. Unleaded gasoline Diesel Leaded gasoline Kerosene 5% methanol/95% unleaded Jet fuel 15% ethanol/85% unleaded Aviation gasoline Installation Accessories Universal Sensor Mounting Kit, P/N , contains mounting brackets and screws (see Fig. 1). Optional 20-foot cable - P/N Visit our website at for more information on Veeder-Root products and services. 4

10 Sump Sensor The sensor is installed in a tank piping sump and will detect the presence of a liquid. Liquid level is monitored by a float /magnetic reed switch sensing system. Fuel alarm is triggered when liquid reaches a nominal height of 1-inch. An open sensor triggers a Sensor Out alarm. Operating temperature range: 0 to +60 C. Storage temperature range: -40 to +70 C. Sensor dimensions: 12 high, 1.9 diameter. Sensor/Cable Length Configurations Sump Sensor w/ 12 foot cable - Form Number Sump Sensor w/ 30 foot cable - Form Number TLS-350 Series Consoles (except TLS-350J) - Interstitial (Form Number ) accepts up to 8 sensors (a maximum of 64 sensors could be monitored by the console). TLS-350J Console - 3 sensors max. TLS-300/PC-300 Series Consoles (no Interface Module required) - 8 sensors max. ILS-350 Console - A Two-Wire Module (Form Number ) accepts up to 4 sensors (a maximum of 16 sensors could be monitored by the console). Version 1 or later (TLS-350 Series/TLS-300 Consoles) All ILS-350 Consoles Unleaded gasoline Leaded gasoline Diesel Kerosene Jet fuel Aviation gasoline 5% methanol/95% unleaded 15% ethanol/85% unleaded IMPORTANT! DO NOT MOUNT SENSOR TO FLEXIBLE PRODUCT LINE. Cable to junction box and seal-off Existing conduit or piping Cable to junction box and seal-off Product pipe Visit our website at for more information on Veeder-Root products and services. *Sump sensor should: 1. Rest on the base of the sump. 2. Be positioned as close to outer wall as possible. 3. Be mounted in a true vertical position. 4. Be installed only in a dry sump. Sump sensor* (installation examples) Sump base sensors\pssenap.eps Fig. 2 Typical Sump Sensor Installation 5

11 Mag Sump Sensor The Mag Sump Sensor detects the presence and amount of water and/or fuel in the containment sump or dispenser pan. Using proven magnetostrictive technology to detect the presence of hydrocarbons and water, the station (where allowed) remains in operation when water alone is detected. An alarm is also generated if the sensor has been moved from its proper position at the bottom of the sump or pan. Fuel Alarm - triggered when fuel reaches approximately 1.5 in height. Water Warning Alarm - triggered when water level reaches approximately 1.7 in height (or other programmable height). Installation Alarm - triggered when sensor is moved from proper operating position. Comm Alarm - triggered when there is no communication with the sensor. Operating temperature range: -40 to +60 C. Storage temperature range: -40 to +60 C. Sensor Models and Accessories Mag Sensor for gasoline and diesel - 12 high w/ 10 foot cable - Form Number Mag Sensor for gasoline and diesel (w/ leak detect capability)- 12 high w/ 10 foot cable - Form Number Mag Sensor for gasoline and diesel - 24 high w/ 10 foot cable - Form Number Mag Sensor for gasoline and diesel (w/ leak detect capability) - 24 high w/ 10 foot cable - Form Number Universal Sensor Mounting Kit (optional) - Form Number TLS-350R/EMC w/bir, TLS-350 Plus/EMC Enhanced, and TLS-350/EMC - Smart (Form Number ) accepts up to 8 sensors (up to 64 sensors could be monitored by the console) Version 24 or later - all consoles Unleaded gasoline Leaded gasoline Diesel Kerosene Jet fuel Aviation gasoline 5% methanol/95% unleaded 15% ethanol/85% unleaded Dispenser containment sump Cord grip Product line IMPORTANT! DO NOT MOUNT SENSOR TO FLEXIBLE PRODUCT LINE. U-channel Brackets, clamp, etc., from optional Universal sensor mounting kit 1/2'' Rigid conduit to console Rubber grommet seal clamped on inside - or as recommended by dispenser pan manufacturer. Visit our website at for more information on Veeder-Root products and services. Weatherproof junction box with 1/2-inch N.P.T. threads (16 cubic inch volume minimum). Seal-off sensors\msdissump.eps Incorrect Sensor Correct Fig. 3 Typical Mag Sump Sensor Installation in Containment Sump 6

12 Position-Sensitive Sensor The sensor is installed in a pan/sump and incorporates a float switch to detect water and/or hydrocarbons. The sensor also alarms if it is moved off the bottom of the pan/sump. Fuel alarm is triggered when liquid reaches a nominal height of 1-1/2 inches. Sensor Out alarm is triggered when sensor is moved off bottom of the pan/sump. Operating temperature range: 0 to +60 C. Storage temperature range: -40 to +70 C. Sensor dimensions: 12 high, 2.2 diameter. Sensor/Cable Length Configurations Position-Sensitive Sensor w/ 12 foot cable - Form Number TLS-350 Series Consoles (except TLS-350J) - Interstitial (Form Number ) accepts up to 8 sensors (a maximum of 64 sensors could be monitored by the console). TLS-350J Console - 3 sensors max. TLS-300/PC-300 Series Consoles (no Interface Module required) - 8 sensors max. ILS-350 Console - A Two-Wire Module (Form Number ) accepts up to 4 sensors (a maximum of 16 sensors could be monitored by the console). Version 1 or later (TLS-350 Series/TLS-300 Consoles) All ILS-350 Consoles Unleaded gasoline Leaded gasoline Diesel Kerosene Jet fuel Aviation gasoline 5% methanol/95% unleaded 15% ethanol/85% unleaded Submersible pump Containment sump Sensor Cord grip Weatherproof junction box Seal-off 1/2'' Rigid conduit to console Visit our website at for more information on Veeder-Root products and services. IMPORTANT! DO NOT MOUNT SENSOR TO FLEXIBLE PRODUCT LINE. sensors\psstpsump.eps Brackets, clamp, etc. from optional Universal sensor mounting kit Product line IMPORTANT! Housing must compress position indicator against bottom of the sump or you will have a 'Sensor Out' alarm. Incorrect Correct Fig. 4 Typical Position-Sensitive Sensor Installation 7

13 Stand-Alone Dispenser Pan Sensors The Stand-Alone Dispensers immediately shut down AC power to the dispenser when fluid is detected in the dispenser pan. These sensors control and shut down power to the dispenser without the need for additional relays, circuitry, wiring, or consoles. The separate sensor control interface ensures intrinsically-safe integrity in a Class I Division II hazardous area. Two models of Stand-Alone Dispenser Pan sensors are available: Stand-Alone Dispenser Pan Sensor - liquid level detection only (Form Number ). Discriminating Stand-Alone Dispenser Pan Sensor - separate liquid level detection for hydrocarbons and water (Form Number ). Non-Discriminating Stand-Alone Dispenser Pan Sensor Dispenser shut down when liquid level reaches a nominal height of 1.5-inch in sensor. Discriminating Stand-Alone dispenser Pan Sensor Dispenser shut down either when hydrocarbon level reaches a nominal height of inches in sensor, or when water reaches a nominal height of 6.5-inches in sensor. Operating temperature range: 0 to +70 C (for freezing liquids), -40 to +70 C (for hydrocarbons). Storage temperature range: -40 to +70 C. Controls most manufacturer s dispensers. Connects directly to dispenser wiring. Latching alarm circuitry ensures dispenser can t be restarted until hazardous condition has been corrected. Cable length: 5 feet. Sensor dimensions: 11.6 high, 2.2 diameter. Control Interface dimensions: 9.4 high, 2.2 diameter. Unleaded gasoline Diesel Leaded gasoline Kerosene 5% methanol/95% unleaded Jet fuel 15% ethanol/85% unleaded Aviation gasoline Installation Accessories Universal Sensor Mounting Kit, P/N , contains sensor mounting brackets and screws. Visit our website at for more information on Veeder-Root products and services. Power 120 Vac Neutral Existing conduit 1-1/2" to 3/4" Reducer 3/4" nipple (not supplied) Junction box *Dispenser pan sensor should: 1. Rest in the cup or the lowest point of the dispenser pan. 2. Be positioned so as to be removable by pulling the sensor straight up out of the pan. 3. Be mounted in a true vertical position. To Dispenser Pan Sensor Dispenser Control Interface 2.2" dia x 9.4" high To dispenser Existing conduit 1-1/2" coupling To Dispenser Control Interface Optional Universal Sensor mounting kit Dispenser pan sensor* 2.2" dia. x 13" high Switch point 1.5" from bottom of sensor. sensors/sdpsenap.eps Fig. 5 Typical Interstitial Sensor Install - Fiberglass UST 8

14 Discriminating Interstitial Sensor for Double-Wall Fiberglass Tanks The Discriminating Interstitial Sensor for double-wall fiberglass tanks uses ultrasonic liquid level sensing technology to detect liquid in the interstitial space of the tank. The sensor also can differentiate between hydrocarbons and other liquids. Hydrocarbons trigger a Fuel Alarm. Liquid other than hydrocarbons trigger a Water Alarm. An open sensor triggers a Sensor Out Alarm. Operating temperature range: -10 to +55 C. Storage temperature range: -40 to +70 C. Sensor dimensions: 4.3 length, 1.5 width, 0.5 thickness. Console Compatibility TLS-350R, PC-350R, TLS-350Plus, and PC-350Plus Consoles Version 2 or later. Type A Interface Module (Form Number ) accepts up to 8 sensors (a maximum of 64 sensors could be monitored by the console). Unleaded gasoline Diesel Leaded gasoline Kerosene 5% methanol/95% unleaded Jet fuel 15% ethanol/85% unleaded Aviation gasoline Sensor/Cable Length Configuration Discriminating Interstitial Sensor for Fiberglass Tanks with 25-foot cable - Form Number '' min. dia. manhole 4'' dia. riser Cord grip Seal-off 1/2'' rigid conduit (to Console) Weatherproof junction box with 1/2-inch N.P.T. threads (16 Cubic inch volume minimum) Visit our website at for more information on Veeder-Root products and services. Sensor Switch must reach bottom of tank Fiberglass tank sensors\dfsenap.eps Fig. 6 Typical Interstitial Sensor Installation - Steel UST 9

15 Interstitial Sensors for Fiberglass Tanks The Interstitial Sensor for Fiberglass Tanks detects the presence of liquid between the double walls of the tank. The presence of any liquid in the tank s interstitial space triggers a Fuel Alarm. An open sensor triggers a Sensor Out alarm. Operating temperature range: 0 to +70 C (for water), -20 to 70 C (for hydrocarbons). Storage temperature range: -40 to +70 C. Sensor dimensions: 2.2 length, 1.3 width, 0.6 thickness. TLS-350 Series Consoles (except TLS-350J) - Interstitial (Form Number ) accepts up to 8 sensors (a maximum of 64 sensors could be monitored by the console). TLS-350J Console - 3 sensors max. TLS-300i, PC-300i, TLS-300C, TLS-300J, PC-300C Consoles (no Interface Module required) - 8 sensors max. ILS-350 Console -A Two-Wire Module (Form Number ) accepts up to 4 sensors (a maximum of 16 sensors could be monitored by the console). Version 1 or later (TLS-350 Series/TLS-300 Consoles) All ILS-350 Consoles Unleaded gasoline Diesel Leaded gasoline Kerosene 5% methanol/95% unleaded Jet fuel 15% ethanol/85% unleaded Aviation gasoline Sensor/Cable Length Configurations Interstitial Sensors for various diameter Fiberglass tanks: 4 to 5-foot dia. tank - Form Number to 7-foot dia. tank - Form Number to 9-foot dia. tank - Form Number to 12-foot dia. tank - Form Number See Fig. 5 for a typical installation diagram. Visit our website at for more information on Veeder-Root products and services. 10

16 Interstitial Sensors for Steel Tanks The Interstitial Sensor for Steel Tanks detects the presence of liquid between the double walls of the tank. The presence of any liquid at a nominal height of 1 inch in the tank s interstitial space triggers a Fuel Alarm. An open sensor triggers a Sensor Out alarm. Operating temperature range: 0 to +70 C (for water), -20 to 70 C (for hydrocarbons). Storage temperature range: -40 to +70 C. Sensor dimensions: 2.5 high, 1.5 diameter. TLS-350 Series Consoles (except TLS-350J) - Interstitial (Form Number ) accepts up to 8 sensors (a maximum of 64 sensors could be monitored by the console). TLS-350J Console - 3 sensors max. TLS-300i, PC-300i, TLS-300C, TLS-300J, PC-300C Consoles (no Interface Module required) - 8 sensors max. ILS-350 Console -A Two-Wire Module (Form Number ) accepts up to 4 sensors (a maximum of 16 sensors could be monitored by the console). Version 1 or later (TLS-350 Series/TLS-300 Consoles) All ILS-350 Consoles Unleaded gasoline Diesel Leaded gasoline Kerosene 5% methanol/95% unleaded Jet fuel 15% ethanol/85% unleaded Aviation gasoline Sensor/Cable Length Configurations Interstitial Sensor with 16-foot cable - Form Number Interstitial Sensor with 30-foot cable - Form Number Accessories Riser cap and adaptor kit (2 ) - Kit Number /2" to 2" Reducer Leader cable 2'' dia. riser Sensor 14'' min. dia. manhole Cord grip Seal-off 1/2'' rigid conduit (to Console) Weatherproof junction box with 1/2-inch N.P.T. threads (16 Cubic inch volume minimum) Steel tank Visit our website at for more information on Veeder-Root products and services. Sensor Switch must rest on bottom of tank sensors\intsenap.eps Fig. 7 Typical Interstitial MicroSensor Installation - Steel UST 11

17 MicroSensor The small, solid-state MicroSensor with its stiff, easy to push cable, is designed for liquid detection in any confined space, such as the interstitial space of a steel tank or a fill riser containment. The presence of any liquid in the sensing location triggers a Fuel Alarm. An open sensor triggers a Sensor Out Alarm. Operating temperature range: -32 to +60 C. Storage temperature range: -40 to +70 C. Cable length: 25 feet Sensor dimensions: 0.8 high, 0.4 high, 2.2 long. Compatible Consoles TLS-350Plus, PC-350Plus, TLS-350R, PC-350R Consoles 1/2'' to X'' reducer (x = riser diameter) Minimum riser diameter 1 inch Sensor cable 14'' min. dia. manhole Weatherproof junction box Cord grip Seal-off 1/2-inch rigid conduit (to Console) Type A Interface Module (Form Number ) accepts up to 8 sensors (a maximum of 64 sensors could be monitored by a console). Version 2 or later. sensors\missenap.eps Steel tank Sensor must rest on bottom of tank Fig. 8 Typical Interstitial MicroSensor Installation - Steel UST Unleaded gasoline Diesel Leaded gasoline Kerosene 5% methanol/95% unleaded Jet fuel 15% ethanol/85% unleaded Aviation gasoline Sensor/Cable Length Configuration MicroSensor with 25-foot cable - Form Number '' min. dia. manhole MicroSensor Seal-off Riser 1/2'' rigid conduit (to Console) 1/2'' rigid conduit Weatherproof junction box (16 cubic inch volume minimum) Accessories Riser cap and adaptor kit (2 ) - Kit number Visit our website at for more information on Veeder-Root products and services. sensors\mrsenap.eps 1'' N.P.T. threads 1'' conduit Steel tank Riser containment Fig. 9 Typ. MicroSensor Installation in Riser Containment - Steel UST 12

18 Hydrostatic Reservoir Sensor The Hydrostatic Reservoir Sensor accurately detects fluid level change in the reservoir and interstice of a doublewall storage tank. This sensor is available in a dual-point or single-point configuration. The Dual-Point version is ideal for high groundwater areas, and can differentiate between a high level alarm condition and a low level alarm condition. If an inner-wall leak occurs, the brine seeps into the tank triggering a low level alarm, if an outer wall leak occurs, fluid seeps into the interstice triggering a high level alarm. The Single-Point version can be used in low groundwater locations. If an inner-wall leak occurs, the brine seeps into the tank triggering a low level alarm, or if the outer wall leaks, the brine seeps out of the tank interstice triggering a low level alarm. Dual-Point Version - Leak in inner wall triggers a low level alarm - Leak in outer wall triggers a high level alarm in high groundwater areas or a low level alarm in low groundwater areas. An open sensor triggers a Sensor Out alarm. Single-Point Version Leak in inner or outer wall triggers a Fuel alarm in low groundwater areas. An open sensor triggers a Sensor Out alarm. Operating temperature range: -25 to +50 C. Storage temperature range: -40 to +60 C. Operates in salt brine solution of up to 30% CaCl. Cable length: 12 feet Sensor dimensions: Single Point - 6 high, 2.5 diameter; Dual Point high, 2.5 diameter. TLS-350 Series Consoles (except TLS-350J) - Interstitial (Form Number ) accepts up to 8 sensors (a maximum of 64 sensors could be monitored by the console). TLS-350J Console - 4 sensors max. TLS-300i, PC-300i, TLS-300C, TLS-300J, PC-300C Consoles (no Interface Module required) - 8 sensors max. Version 1 or later (TLS-350 Series/TLS-300 Consoles) 14'' min. dia. manhole Cord grip nut/bushing Sensor Configuration Single-Point Sensor - Form Number Dual-Point Sensor - Form Number Visit our website at for more information on Veeder-Root products and services. Concrete slab or packed earth per NFPA 80 Dual-point hydrostatic sensor Brine level Riser pipe cap Float Weatherproof junction box Seal-off 1/2'' rigid conduit (to Console) Reservoir Double-wall tank sensors\hssenap.eps Fig. 10 Typical Hydrostatic Dual-Point Sensor Installation 13

19 Single-Point Mini Hydrostatic Sensor for Double Wall Sumps The Single-Point Mini Hydrostatic sensor accurately detects fluid level change in the interstice reservoir of a double-wall sump. If a leak occurs in the sump interstice, the brine seeps out of the reservoir triggering a low level alarm. A leak in the inner or outer sump wall triggers a Fuel alarm. An open sensor triggers a Sensor Out alarm. Operating temperature Range: -25 C to +50 C. Rests in salt brine solution of up to 30% calcium chloride. Storage Temperature Range: -40 C to + 60 C. Dimensions: 2.5 high, 1.50 diameter Cable length: 8 feet TLS-350 Series Consoles (except TLS-350J) - Interstitial (Form Number ) accepts up to 8 sensors (a maximum of 64 sensors could be monitored by the console). TLS-350J Console - 4 sensors max. TLS-300i, PC-300i, TLS-300C, TLS-300J, PC-300C Consoles (no Interface Module required) - 8 sensors max. Version 1 or later (TLS-350 Series/TLS-300 Consoles) Sensor and Installation Kit Single-Point Mini Hydrostatic Sensor and install kit for double-wall sumps - P/N Visit our website at for more information on Veeder-Root products and services. Fig. 1 Typical Single-Point Mini-Hydrostatic Sensor Installation 14

20 Vapor Sensor The Vapor Sensor detects the presence of hydrocarbon vapors in dry monitoring wells. Hydrocarbon vapor exceeding the programmed threshold triggers a Fuel Alarm. Liquid present in the monitoring well triggers a Water Alarm. An open sensor triggers a Sensor Out alarm. Operating temperature range: -20 to +70 C. Storage temperature range: -40 to +70 C. Sensor dimensions: 4.9 long, 1.1 diameter. Lockable, watertight cap for 4 monitoring wells prevents accidental spills into well. TLS-350 Series Consoles (except TLS-350J) - Vapor (Form Number ) accepts up to 5 sensors (a maximum of 40 sensors could be monitored by the console). ILS-350 Console -A three-wire Module (Form Number ) accepts up to 4 sensors (a maximum of 16 sensors could be monitored by the console). Version 1 or later (TLS-350 Series Consoles) All ILS-350 Consoles Unleaded gasoline Diesel Leaded gasoline Kerosene 5% methanol/95% unleaded Jet fuel 15% ethanol/85% unleaded Aviation gasoline Sensor Configuration Vapor Sensor - Form Number Accessories 4-inch cap - Part Number Visit our website at for more information on Veeder-Root products and services. 14'' min. dia. manhole Cord grip Seal-off Weatherproof junction box with 1/2-inch N.P.T. threads (16 cubic inch volume minimum) Perforated PVC monitoring well housing Vapor sensor 1/2'' rigid conduit (to Console) Suspend vapor sensor 12 inches above highest level reached by water table, if known; or 12 inches above the bottom of the well or any water in the well. sensors\vsenap.eps Fig. 12 Typical Vapor Sensor Installation 15

21 Groundwater Sensor The Groundwater Sensor detects free hydrocarbon product on the water table in up to 20 feet deep monitoring wells. Hydrocarbons in the C 5 to C 16 range trigger a Fuel Alarm. Sensor detects as little as 0.1 depth of free product on the water table. Water table dropping below sensor triggers a Water Out Alarm. An open sensor triggers a Sensor Out alarm. Operating temperature range: 0 to +40 C. Storage temperature range: -40 to +70 C. Sensor dimensions: 4.9 long, 1.1 diameter. TLS-350 Series Consoles (except TLS-350J) - Vapor (Form Number ) accepts up to 5 sensors (a maximum of 40 sensors could be monitored by the console). ILS-350 Console -A three-wire Module (Form Number ) accepts up to 4 sensors (a maximum of 16 sensors could be monitored by the console). Version 1 or later (TLS-350 Series Consoles) All ILS-350 Consoles Unleaded gasoline Diesel Leaded gasoline Kerosene 5% methanol/95% unleaded Jet fuel 15% ethanol/85% unleaded Aviation gasoline Sensor Configurations Groundwater Sensors for various depth wells: 7 to 10-foot wells- Form Number to 15-foot wells- Form Number to 20-foot wells- Form Number Sensor well cap w/ locking handle 14'' min. dia. manhole Extra sensor length should not exceed 2-feet Sensor Cord grip Seal-off Weatherproof junction box with 1/2-inch N.P.T. threads (16 cubic inch volume minimum) Perforated PVC monitoring well housing 1/2'' rigid conduit (to Console) Visit our website at for more information on Veeder-Root products and services. Water float Suspend water float 2''- 4'' above bottom of well. NOTE: Water float must be submerged or console will indicate WATER OUT alarm. Fig. 13 Typical Groundwater Sensor Installation sensors\gwsenap.eps 16

22 Headquarters 125 Powder Forest Drive Simsbury, CT Tel: (860) Fax: (860)

Manual No: Revision: D. Mag Sump Sensor. Installation Guide

Manual No: Revision: D. Mag Sump Sensor. Installation Guide Manual No: 577013-812 Revision: D Mag Sump Sensor Installation Guide Notice Veeder-Root makes no warranty of any kind with regard to this publication, including, but not limited to, the implied warranties

More information

Manual No: Revision: D. Sump Sensor. Installation Guide

Manual No: Revision: D. Sump Sensor. Installation Guide Manual No: 576013-301 Revision: D Sump Sensor Installation Guide Notice Veeder-Root makes no warranty of any kind with regard to this publication, including, but not limited to, the implied warranties

More information

Manual No: Revision: E. Groundwater Sensor. Installation Guide

Manual No: Revision: E. Groundwater Sensor. Installation Guide Manual No: 576013-763 Revision: E Groundwater Sensor Installation Guide Notice Veeder-Root makes no warranty of any kind with regard to this publication, including, but not limited to, the implied warranties

More information

Manual No: Revision: C. Overfill Alarm. Installation Guide

Manual No: Revision: C. Overfill Alarm. Installation Guide Manual No: 576013-589 Revision: C Overfill Alarm Installation Guide Notice Veeder-Root makes no warranty of any kind with regard to this publication, including, but not limited to, the implied warranties

More information

Single-Point Mini Hydrostatic Sensor for Double-Wall Sumps

Single-Point Mini Hydrostatic Sensor for Double-Wall Sumps Manual No: 577013-838 Revision: B Single-Point Mini Hydrostatic Sensor for Double-Wall Sumps Installation Guide Notice Veeder-Root makes no warranty of any kind with regard to this publication, including,

More information

Manual No: Revision: H. MicroSensor. Installation Guide

Manual No: Revision: H. MicroSensor. Installation Guide Manual No: 576013-285 Revision: H MicroSensor Installation Guide Notice Veeder-Root makes no warranty of any kind with regard to this publication, including, but not limited to, the implied warranties

More information

Remanufactured Veeder-Root Discriminating Dispenser Pan and Containment Sump Sensors

Remanufactured Veeder-Root Discriminating Dispenser Pan and Containment Sump Sensors Manual Number: 01-61-133 Revision : 1.8 Date: 10/27/16 Installation Instructions Remanufactured Veeder-Root Discriminating Dispenser Pan and Containment Sump Sensors PMP # 62322, 62352 Replaces Veeder-Root

More information

Interstitial Liquid Sensor - Fiberglass Tanks

Interstitial Liquid Sensor - Fiberglass Tanks Manual No: 576013-617 Revision: J Interstitial Liquid Sensor - Fiberglass Tanks Installation Guide Notice Veeder-Root makes no warranty of any kind with regard to this publication, including, but not limited

More information

2 To 1 Sensor Input Box

2 To 1 Sensor Input Box Manual No: 577013-869 Revision: D 2 To 1 Sensor Input Box Installation Guide Notice Veeder-Root makes no warranty of any kind with regard to this publication, including, but not limited to, the implied

More information

FMP-ULS UNIVERSAL LIQUID SENSOR INSTALLATION GUIDE

FMP-ULS UNIVERSAL LIQUID SENSOR INSTALLATION GUIDE FMP-ULS UNIVERSAL LIQUID SENSOR INSTALLATION GUIDE The information in this publication is provided for reference only. While every effort has been made to ensure the reliability and accuracy of the information

More information

Manual No: Revision: J. Groundwater Sensor. Installation Guide

Manual No: Revision: J. Groundwater Sensor. Installation Guide Manual No: 576013-763 Revision: J Groundwater Sensor Installation Guide Notice Veeder-Root makes no warranty of any kind with regard to this publication, including, but not limited to, the implied warranties

More information

Installation Instructions. Remanufactured Veeder-Root Steel Tank Interstitial Sensor. PMP # 62420, Replaces Veeder-Root # , -460

Installation Instructions. Remanufactured Veeder-Root Steel Tank Interstitial Sensor. PMP # 62420, Replaces Veeder-Root # , -460 Manual Number: 01-60-309 Revision : 5.5 Installation Instructions Remanufactured Veeder-Root Steel Tank Interstitial Sensor PMP # 62420, 62460 Replaces Veeder-Root #794380-420, -460 Contents Disclaimer...

More information

FMP-MWS. (Discriminating Monitoring Well Sensor BriteSensor ) Installation Instructions

FMP-MWS. (Discriminating Monitoring Well Sensor BriteSensor ) Installation Instructions FMP-MWS (Discriminating Monitoring Well Sensor BriteSensor ) Installation Instructions Franklin Fueling Systems 3760 Marsh Rd. Madison, WI 53718 USA Tel: +1 608 838 8786 800 225 9787 Fax: +1 608 838 6433

More information

FMP-HIS AND FMP-HIS-U INSTALLATION GUIDE

FMP-HIS AND FMP-HIS-U INSTALLATION GUIDE FMP-HIS AND FMP-HIS-U INSTALLATION GUIDE The information in this publication is provided for reference only. While every effort has been made to ensure the reliability and accuracy of the information contained

More information

FMP-DVS. Monitoring Well Discriminating Vapor Sensor (BriteSensor ) Installation Instructions

FMP-DVS. Monitoring Well Discriminating Vapor Sensor (BriteSensor ) Installation Instructions FMP-DVS Monitoring Well Discriminating Vapor Sensor (BriteSensor ) Installation Instructions Franklin Fueling Systems 3760 Marsh Rd. Madison, WI 53718 USA Tel: +1 608 838 8786 800 225 9787 Fax: +1 608

More information

FMP-DDS & FMP-DTS. Discriminating Dispenser Sump & Turbine Sump BriteSensor. Installation Instructions

FMP-DDS & FMP-DTS. Discriminating Dispenser Sump & Turbine Sump BriteSensor. Installation Instructions & Discriminating Dispenser Sump & Turbine Sump Brite Installation Instructions Franklin Fueling Systems 3760 Marsh Rd. Madison, WI 53718 USA Tel: +1 608 838 8786 800 225 9787 Fax: +1 608 838 6433 www.franklinfueling.com

More information

Installation Instructions. Remanufactured Veeder-Root Position Sensitive Sump Sensor. PMP # Replaces Veeder-Root #

Installation Instructions. Remanufactured Veeder-Root Position Sensitive Sump Sensor. PMP # Replaces Veeder-Root # Manual Number: 01-61-141 Revision : 1.7 Date: 10/27/16 Installation Instructions Remanufactured Veeder-Root Position Sensitive Sump Sensor PMP # 62323 Replaces Veeder-Root #794380-323 Contents Disclaimer...

More information

Installation Instructions Manual No: Revision F

Installation Instructions Manual No: Revision F FXV Leak Detectors Installation Instructions Manual No: 042-106-1 Revision F Notice Veeder-Root makes no warranty of any kind with regard to this publication, including, but not limited to, the implied

More information

Installation Instructions. Remanufactured Veeder-Root Sump Sensor. PMP # 62208, Replaces Veeder-Root # , -209

Installation Instructions. Remanufactured Veeder-Root Sump Sensor. PMP # 62208, Replaces Veeder-Root # , -209 Manual Number: 01-60-291 Revision : 5.6 Date: 12/11/15 Installation Instructions Remanufactured Veeder-Root Sump Sensor PMP # 62208, 62209 Replaces Veeder-Root #794380-208, -209 Contents Disclaimer...

More information

TLS Monitoring Systems

TLS Monitoring Systems Manual No: 57703-578 Revision: V TLS Monitoring Systems Contractors Site Preparation Guide Notice Veeder-Root makes no warranty of any kind with regard to this publication, including but not limited to,

More information

FMP-DIS & FMP-EIS. Interstitial BriteSensor & Standard Sensor. Installation Instructions

FMP-DIS & FMP-EIS. Interstitial BriteSensor & Standard Sensor. Installation Instructions FMP-DIS & FMP-EIS Interstitial BriteSensor & Standard Sensor Installation Instructions FMP-DIS Sensor FMP-EIS Sensor Franklin Fueling Systems 3760 Marsh Rd. Madison, WI 53718 USA Tel: +1 608 838 8786 800

More information

TLS-350R UST Monitoring and Leak Detection System With Automatic Business Reconciliation

TLS-350R UST Monitoring and Leak Detection System With Automatic Business Reconciliation Part 1 General System Requirements 1.1 Description TLS-350R UST Monitoring and Leak Detection System With Automatic Business Reconciliation A. These Specifications are intended to provide information by

More information

Instructions for using the KWA LS-2003 Leak Detector Tester are on Page 7 of the Veeder-Root Operational Testing Guide

Instructions for using the KWA LS-2003 Leak Detector Tester are on Page 7 of the Veeder-Root Operational Testing Guide Instructions for using the KWA LS-2003 Leak Detector Tester are on Page 7 of the Veeder-Root Operational Testing Guide Manual No: 577013-814 Revision: A Operability Testing Guide Line Leak Detection Systems,

More information

BID-SPEC_INTEGRA_100 Rev. 0. Bid Specifications and General Description OPW SiteSentinel Integra 100 Automatic Tank Monitoring System

BID-SPEC_INTEGRA_100 Rev. 0. Bid Specifications and General Description OPW SiteSentinel Integra 100 Automatic Tank Monitoring System BID-SPEC_INTEGRA_100 Rev. 0 Bid Specifications and General Description OPW SiteSentinel Integra 100 Automatic Tank Monitoring System Part 1. General Overview 1.1 Summary This document describes the minimum

More information

Colibri. Automatic Tank Gauge CL6 Series Installation Guide

Colibri. Automatic Tank Gauge CL6 Series Installation Guide Colibri Automatic Tank Gauge CL6 Series Installation Guide Manual # Revision Date Changes from Previous Revision 000-2153 C Jan. 2013 Pipe compound brand change, Updated Control drawing. Franklin Fueling

More information

Automatic Tank Gauging and Line Leak Detection System Bid Specification TS-550evo Fuel Management System

Automatic Tank Gauging and Line Leak Detection System Bid Specification TS-550evo Fuel Management System Automatic Tank Gauging and Line Leak Detection System Bid Specification TS-550evo Fuel Management System Franklin Fueling Systems 000-1739 r3, November 2017 An ISO 9001 Registered Company Part 1 General

More information

Electronic Fuel Management Systems

Electronic Fuel Management Systems Electronic Fuel Management Systems Making Sure You re in Complete Control, From Anywhere, All The Time. Innovation is a defining value principle at OPW Fuel Management Systems (FMS). OPW FMS provides the

More information

M1500 SiteSentinel itouch Tank-Gauge Monitoring System Installation Guide. Part Number: M1500, Rev. 5

M1500 SiteSentinel itouch Tank-Gauge Monitoring System Installation Guide. Part Number: M1500, Rev. 5 Part Number: M1500, Rev. 5 Issue Date: May 17, 2016 Supersedes: May 30, 2012 M1500 SiteSentinel itouch Tank-Gauge Monitoring System Installation Guide 6900 Santa Fe Drive Hodgkins, IL 60525 Tel: (708)

More information

Installation Manual INTEGRATED MONITORING SYSTEM.

Installation Manual INTEGRATED MONITORING SYSTEM. INTEGRATED MONITORING SYSTEM Installation Manual Central Technical Support Number: 1-877-OPW-TECH (877-679-8324) Calls outside US and Canada: 1-708-485-4200 Fax: 1 (800) 421-3297 Hours: Monday through

More information

KWA. Evaluation of the Morrison Bros. Co. Liquid Sensor, Adjustable Level Sensor and Multi-Level Sensor. Final Report

KWA. Evaluation of the Morrison Bros. Co. Liquid Sensor, Adjustable Level Sensor and Multi-Level Sensor. Final Report Evaluation of the Morrison Bros. Co. Liquid Sensor, Adjustable Level Sensor and Multi-Level Sensor 924LS, 924 and 925 Sensor for use with the 918AC, 918S, 918D and 918Q Alarm Consoles Final Report PREPARED

More information

SiteSentinel Integra 100 /500 Automatic Tank Gauge System Installation Manual

SiteSentinel Integra 100 /500 Automatic Tank Gauge System Installation Manual SiteSentinel Integra 100 /500 Automatic Tank Gauge System Installation Manual Central Technical Support Number: 1-877-OPW-TECH (877-679-8324) Calls outside US and Canada: 1-708-485-4200 Fax: 1 (800) 421-3297

More information

Variable Speed Flow Controller

Variable Speed Flow Controller Variable Speed Flow Controller Installation Guide IMPORTANT NOTICE! A V-R PLLD Pressure Transducer must be installed in the STP and connected to the Variable Speed Flow Controller (VSFC) for the VSFC to

More information

Installation Instructions. Remanufactured Veeder-Root Overfill Alarm and. Acknowledgement Switch. Overfill Alarm PMP # OEM #

Installation Instructions. Remanufactured Veeder-Root Overfill Alarm and. Acknowledgement Switch. Overfill Alarm PMP # OEM # Manual Number: 01-62-768 Revision : 1.2 Date: 03/20/17 Installation Instructions Remanufactured Veeder-Root Overfill Alarm and Acknowledgement Switch Overfill Alarm PMP # 62625 OEM # 790091-001 Acknowledgement

More information

SAFETY INFORMATION AND WARNINGS

SAFETY INFORMATION AND WARNINGS This manual refers to the Model SST-3 control panel manufactured since October 31, 2013, which uses a universal (100 277 VAC; 50/60 Hz) power supply. Older units use a voltage-specific power supply and

More information

Instruction Manual. Bucket Oil Pump

Instruction Manual. Bucket Oil Pump Instruction Manual Bucket Oil Pump 10700 Medallion Drive, Cincinnati, Ohio 45241-4807 USA 2016 Gold Medal Products Co. Part No. 79064E SAFETY PRECAUTIONS DANGER Machine must be properly grounded to prevent

More information

INSTRUCTION MANUAL. Revised: July 2, 2017 DRAWING NO REV. A LC1000 SERIES INTRINSICALLY SAFE ALARM CONSOLE

INSTRUCTION MANUAL. Revised: July 2, 2017 DRAWING NO REV. A LC1000 SERIES INTRINSICALLY SAFE ALARM CONSOLE PNEUMERCATOR Liquid Level Control Systems AUDIBLE ALARM CONTROLS INSTRUCTION MANUAL Revised: July 2, 2017 DRAWING NO. 20000 REV. A LC1000 SERIES INTRINSICALLY SAFE ALARM CONSOLE COPYRIGHT 2017 PNEUMERCATOR

More information

NEUTRONICS MINI ID R-1234yf REFRIGERANT IDENTIFIER OPERATION MANUAL

NEUTRONICS MINI ID R-1234yf REFRIGERANT IDENTIFIER OPERATION MANUAL NEUTRONICS MINI ID R-1234yf REFRIGERANT IDENTIFIER OPERATION MANUAL 456 Creamery Way, Exton, PA 19341, USA Phone: 610.524.8800 Fax: 610.524.8807 Email: info@refrigerantid.com www.refrigerantid.com Page

More information

HOTSPOT. Two Gallon Pump Up Spotter OPERATING & MAINTENANCE

HOTSPOT. Two Gallon Pump Up Spotter OPERATING & MAINTENANCE HOTSPOT Two Gallon Pump Up Spotter INTRODUCTION OPERATING & MAINTENANCE INSTRUCTIONS This operator s book has important information for the use and safe operation of this machine. Read this book carefully

More information

DBF 4XL Dryer Booster Fans

DBF 4XL Dryer Booster Fans Installation and Operation Manual Item #: 401315 Rev Date: 050814 DBF 4XL Dryer Booster Fans DBF4XL Kit Includes: Dryer Booster Fan, 1 pc Fan Mounting Bracket and Hardware, 1 pc Wall Label (Mount on wasll

More information

1993 Pond Rd., Ronkonkoma, NY Tank Gauging Liquid Level and Leak Detection Systems Relays. OEL8000II Installation Manual PRINT MENU DEL 1 ABC

1993 Pond Rd., Ronkonkoma, NY Tank Gauging Liquid Level and Leak Detection Systems Relays. OEL8000II Installation Manual PRINT MENU DEL 1 ABC OMNTEC Mfg., Inc. 1993 Pond Rd., Ronkonkoma, NY 11779 Tank Gauging Liquid Level and Leak Detection Systems Relays OEL8000II Installation Manual OMNTEC OEL800OII TANK MONITORING SYSTEM OK FAULT ALARM PRINT

More information

Attachment L Vapor Recovery Tests for Phase I Underground Storage Tanks and Balance Phase II EVR Systems (Veeder Root Vapor Polisher)

Attachment L Vapor Recovery Tests for Phase I Underground Storage Tanks and Balance Phase II EVR Systems (Veeder Root Vapor Polisher) Attachment L Vapor Recovery Tests for Phase I Underground Storage Tanks and Balance Phase II EVR Systems (Veeder Root Vapor Polisher) Phase I EVR Executive Orders VR-101-X, VR-102-X, VR-103-X, VR 104-X,

More information

DEDPV-705, DEDPV-705 Hi Alt Dryer Exhaust Duct Power Ventilator (DEDPV)

DEDPV-705, DEDPV-705 Hi Alt Dryer Exhaust Duct Power Ventilator (DEDPV) Installation and Operation Manual Item #: 483443 Rev Date: 2018-04-23 DEDPV-705, DEDPV-705 Hi Alt Dryer Exhaust Duct Power Ventilator (DEDPV) DEDPV-705 Kit Includes: Inline Fan with Integral Control, 1

More information

OPERATION MANUAL Dated: 04/09/2018 Document Name: SHV _OM Page 1 of 8. Ion Technologies SHV40, 75 & 100 Sewage Ejector Pump SAFETY WARNINGS

OPERATION MANUAL Dated: 04/09/2018 Document Name: SHV _OM Page 1 of 8. Ion Technologies SHV40, 75 & 100 Sewage Ejector Pump SAFETY WARNINGS Ion Technologies SHV40, 75 & 100 Sewage Ejector Pump Page 1 of 8 biohazard risk exists. Installer(s) and/or service personnel must use proper Personal Protective Equipment and follow handling procedures

More information

TS-RA1, TS-RA2 and TS-RK Tank Overfill Alarms

TS-RA1, TS-RA2 and TS-RK Tank Overfill Alarms TS-RA1, TS-RA2 and TS-RK Tank Overfill Alarms Installation Guide franklinfueling.com 3760 Marsh Rd. Madison, WI 53718, USA Tel: +1 608 838 8786 Fax: +1 608 838 6433 Tel: USA & Canada +1 800 225 9787 Tel:

More information

Installation & Maintenance Guide

Installation & Maintenance Guide Installation & Maintenance Guide Internal Mini Skimmer 115 For Model 510114 Skimmer 30 Gallon www.aquaticlife.com Thank you for purchasing an AquaticLife Internal Mini Skimmer for use with your marine

More information

A System That Utilizes the LD-2000 or LD-3000 Mechanical Line Leak Detector to Perform 3 10 PSI (catastrophic) Line Tests

A System That Utilizes the LD-2000 or LD-3000 Mechanical Line Leak Detector to Perform 3 10 PSI (catastrophic) Line Tests Overview of the A System That Utilizes the LD-2000 or LD-3000 Mechanical Line Leak Detector to Perform 3 GPH @ 10 PSI (catastrophic) Line Tests Meet EPA Hourly Test Requirement by Performing Line Tests

More information

PLC-5000 FULL SHUT-DOWN SYSTEM INSTALLATION AND OPERATION MANUAL

PLC-5000 FULL SHUT-DOWN SYSTEM INSTALLATION AND OPERATION MANUAL PLC-5000 FULL SHUT-DOWN SYSTEM INSTALLATION AND OPERATION MANUAL Central Control Node Software Version 6.3 Revision Date August 5, 2003 Vaporless Manufacturing 8700 East Long Mesa Road Prescott Valley,

More information

Diesel Exhaust Fluid Compatible Products DEF

Diesel Exhaust Fluid Compatible Products DEF Diesel Exhaust Fluid Compatible Products DEF Aboveground Installation Monitoring Cap & Adaptor 22 Vent 8 or 9 Anti-Siphon Valve or Solenoid Valve 24 Clock Gauge 29 Overfill Alarm Sensor 21 Overfill Shut-Off

More information

MANUAL Rev. C 02/15 (800) Environmental Technology, Inc.

MANUAL Rev. C 02/15 (800) Environmental Technology, Inc. MANUAL We Manage Heat Automatic Snow/Ice Melting System Controller SNOW SWITCH MODEL LCD 8 100 240 VAC Installation and Operation Manual Environmental Technology, Inc. 1850 N Sheridan Street South Bend,

More information

TL-105 COLUMN HEATER

TL-105 COLUMN HEATER TL-105 COLUMN HEATER INSTRUCTION MANUAL Timberline Instruments Inc. 1880 S. Flatiron Ct., Unit I Boulder, Colorado 80301 Ph: (303) 440-8779 Fx: (303) 440-8786 info@timberlineinstruments.com www.timberlineinstruments.com

More information

Fuel Management System Setup Guide

Fuel Management System Setup Guide Fuel Management System Setup Guide EVO-EXPC & EVO-EXPC2 Expansion Consoles for TS-5000 evo and TS-550 evo Franklin Fueling Systems 3760 Marsh Rd. Madison, WI 53718 USA Tel: +1 608 838 8786 800 225 9787

More information

Instruction Sheet LTR - Low Water Cutoff for Hot Water Boilers

Instruction Sheet LTR - Low Water Cutoff for Hot Water Boilers SUPERSEDES: Revision F Dated December 17, 2012 #5401179-REV G PLANT ID 001-3907 Instruction Sheet LTR - Low Water Cutoff for Hot Water Boilers Listings/Approvals EFFECTIVE: June1, 2017 102-338 UL GUIDE

More information

Ultrasonic Reflective Sensor

Ultrasonic Reflective Sensor Ultrasonic Reflective with an Adjustable Sensing Distance of 0.3 to 3 m Under Stable Operation without Background Interference Ensures a stable operating range with minimal side-lobe areas. Built-in unstable

More information

Ultrasonic Reflective Sensor

Ultrasonic Reflective Sensor Ultrasonic Reflective with an Adjustable Sensing Distance of 0.3 to 3 m Under Stable Operation without Background Interference Ensures a stable operating range with minimal side-lobe areas. Built-in unstable

More information

Users Manual. LAURUS Systems, Inc. - Ph: Fax:

Users Manual. LAURUS Systems, Inc. - Ph: Fax: Users Manual LAURUS Systems, Inc. - Ph: 410-465-5558 - Fax: 410-465-5257 - www.laurussystems.com Introduction The rad-d is a security and inspection system that detects emissions from radioactive material.

More information

Construction and Installation Instructions For the A&A Splash Pad

Construction and Installation Instructions For the A&A Splash Pad Construction and Installation Instructions For the A&A Splash Pad Revised 9//09 These instructions are not meant to be detailed construction plans since you will be using your standard plumbing and deck

More information

NOVALYNX CORPORATION MODEL 200-WS-21-A DUAL SET POINT WIND ALARM INSTRUCTION MANUAL

NOVALYNX CORPORATION MODEL 200-WS-21-A DUAL SET POINT WIND ALARM INSTRUCTION MANUAL NOVALYNX CORPORATION MODEL 200-WS-21-A DUAL SET POINT WIND ALARM INSTRUCTION MANUAL REVISION DATE: JAN 2005 Receiving and Unpacking Carefully unpack all components and compare to the packing list. Notify

More information

C Electrical Connection Kit

C Electrical Connection Kit 1548-4010C Electrical Connection Kit For Use With Dekoron 2700 and 2300 Family of Heating Cables Installation Instructions Kit Description The Dekoron 1548-4010C electrical connection and end seal kit

More information

PROTEUS Series OEL8000III-K. Tank Gauging System. Installation Manual

PROTEUS Series OEL8000III-K. Tank Gauging System. Installation Manual OMNTEC PROTEUS Series OEL8000III-K Tank Gauging System Installation Manual Page 1 of 23 PROPRIETARY INFORMATION NOTICE This document contains information and material developed by OMNTEC Mfg., Inc. All

More information

Industrial Strength Leak Detection

Industrial Strength Leak Detection Industrial Strength Leak Detection Don t let an undetected leak or spill ruin the environment or your reputation... TraceTek Technology: Find leaks before major damage is done... TraceTek Technology: Sensor

More information

Check It Panel. 1 Phase Simplex Demand Dose Operation, Maintenance & Installation Manual. Introduction. Safety Guidelines

Check It Panel. 1 Phase Simplex Demand Dose Operation, Maintenance & Installation Manual. Introduction. Safety Guidelines Introduction Before proceeding with the installation or operation of the control panel read all instructions thoroughly, as well as comply with all Federal, State and Local Codes, Regulations and Practices.

More information

AlarmLine Addressable Linear Heat Detector

AlarmLine Addressable Linear Heat Detector Line Addressable Linear Heat Detector P/N 7-0001-00 Effective: March 2008 K-7-02 FEATURES UL Listed FM Approved CSFM MEA (pending) Low-cost interface between Line sensor cable and control panel accepting

More information

MN908 No. 282C Replaces 282B LB7013

MN908 No. 282C Replaces 282B LB7013 No. 282C Replaces 282B LB7013 Instruction Manual For Baldor Dust Control Units Models DC7, DC7 3, DC8, DC8 3, DC10, DC10 3, DC12, DC12 3 and DC14 3. For use on Grinders mounted to GA16 and GA20 pedestals

More information

TLS-4XX Series Consoles

TLS-4XX Series Consoles Manual No: 57703-98 Revision: C Software Version 3A TLS-4XX Series Consoles Troubleshooting Guide Notice Veeder-Root makes no warranty of any kind with regard to this publication, including, but not limited

More information

Ramsey Motion Monitoring Systems

Ramsey Motion Monitoring Systems Ramsey Motion Monitoring Systems 60-200 Motion Monitoring Accurate Sensing of Underspeed, Overspeed and Zero Speed Conditions on Rotating Shafts and Machinery The Ramsey Series 60-200 Motion Monitoring

More information

Ion Endeavor Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

Ion Endeavor Pump Controller Digital Level Control with Pump Alternation and High Water Alarm Ion Endeavor Controller Digital Level Control with Alternation Page 1 of 8 General Overview The Ion Endeavor is a pump controller that senses a water level of up to 72", has a configurable water level/pump

More information

Model CV-1FR Riser Check Valves 2 to 12 Inch (DN50 to DN300) General Description. Installation. Technical Data. Page 1 of 6 OCTOBER 2010 TFP950

Model CV-1FR Riser Check Valves 2 to 12 Inch (DN50 to DN300) General Description. Installation. Technical Data. Page 1 of 6 OCTOBER 2010 TFP950 Technical Services 00--9 +-0--0 www.tyco-fire.com Model CV-FR Riser Check Valves to Inch (DN0 to DN00) General Description The TYCO Model CV-FR Riser Check Valve is a compact and rugged swingtype unit

More information

VEEDER-ROOT CURRENT DATA STORAGE INTERFACE MANUAL. for. TLS-300 and TLS-350 UST Monitoring Systems. and

VEEDER-ROOT CURRENT DATA STORAGE INTERFACE MANUAL. for. TLS-300 and TLS-350 UST Monitoring Systems. and VEEDER-ROOT CURRENT DATA STORAGE INTERFACE MANUAL for TLS-300 and TLS-350 UST Monitoring Systems and TLS-350R Environmental & Inventory Management System through Software Versions 15/115 Manual Number

More information

IN020 Rev F Page 1 of 8

IN020 Rev F Page 1 of 8 IN020 Rev F Page 1 of 8 RadonAway Ward Hill, MA. Series Fan Installation Instructions Please Read and Save These Instructions. DO NOT CONNECT POWER SUPPLY UNTIL FAN IS COMPLETELY INSTALLED. MAKE SURE ELECTRICAL

More information

Xaact Spot. Xaact Hot Spot

Xaact Spot. Xaact Hot Spot Xaact Spot & Xaact Hot Spot INFORMATION & OPERATING INSTRUCTIONS READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE OPERATING THE MACHINE 78-00012 Rev. 101211 1 CONTENTS: Machine Specifications............

More information

Instruction Manual. Portion Cup Cheese Warmer

Instruction Manual. Portion Cup Cheese Warmer Instruction Manual Portion Cup Cheese Warmer Model No. 5581-00-100, 5581-01-100, and 5581-00-101 10700 Medallion Drive, Cincinnati, Ohio 45241-4807 USA 2017 Gold Medal Products Co. Part No. 74797 SAFETY

More information

The DEF-System by BRUGG. The Best Way to defeat the problem of DEF heat Installation Instructions

The DEF-System by BRUGG. The Best Way to defeat the problem of DEF heat Installation Instructions The -System by BRUGG The Best Way to defeat the problem of heat Installation Instructions -System Installation Instructions Content Page 3 Page 4 Page 5 Page 6 Page 7 Description of System Installation

More information

TraceTek Leak Detection

TraceTek Leak Detection R TraceTek Leak Detection Product Selection Guide for Industrial and Environmental Applications Scope of This Guide This guide will help you select TraceTek leak detection products for industrial and environmental

More information

INSTALLATION INSTRUCTIONS GPM SERIES LOOP PUMP MODULES

INSTALLATION INSTRUCTIONS GPM SERIES LOOP PUMP MODULES INSTALLATION INSTRUCTIONS GPM SERIES LOOP PUMP MODULES Bard Manufacturing Company, Inc. Bryan, Ohio 43506 Since 1914...Moving, ahead just as planned. Manual: 2100-212A Supersedes: 2100-212 File: Tab 8

More information

MICROtrac MICROPROCESSOR BASED WATER TREATMENT CONTROLLER. Installation and Operation Manual REV. L

MICROtrac MICROPROCESSOR BASED WATER TREATMENT CONTROLLER. Installation and Operation Manual REV. L MICROtrac MICROPROCESSOR BASED WATER TREATMENT CONTROLLER Installation and Operation Manual MICROtrac Warranty Pulsafeeder, Inc. warrants MICROtrac control systems (including the conductivity sensor) of

More information

SAFETY OPERATION & MAINTENANCE MANUAL X-405 CARPET EXTRACTOR This unit is intended for commercial use.

SAFETY OPERATION & MAINTENANCE MANUAL X-405 CARPET EXTRACTOR This unit is intended for commercial use. SAFETY OPERATION & MAINTENANCE MANUAL X-405 CARPET EXTRACTOR This unit is intended for commercial use. READ AND FOLLOW ALL INSTRUCTIONS, WARNINGS AND CAUTIONS BEFORE USING THIS EXTRACTOR Address: 777 South

More information

AlarmLine Linear Heat Detector

AlarmLine Linear Heat Detector 7.01 7/11/2000 8:1 AM Page 1 CP Scan#1:Desktop Folder:hold:90 Catalog:7.01.job: 7.01 AlarmLine Linear Heat Detector FEATURES Integrating Type Linear Heat Detector Analog Sensing Field Adjustable Alarm

More information

Digital Two Channel Monitor Instruction Manual

Digital Two Channel Monitor Instruction Manual Digital Two Channel Monitor Instruction Manual Model: SM Series Document 040084A0001 Revision # A Dated 02/25/2003 NOTICE The information contained in this document is current as of the date of publication

More information

MODEL HBX-1 P/N 3G59332

MODEL HBX-1 P/N 3G59332 MODEL HBX-1 P/N 3G59332 LIMITED WARRANTY Getz Equipment Innovators warrants its products, and component parts of any product manufactured by Getz Equipment Innovators, to be free from defects in material

More information

Ramsey Series Motion Monitoring Systems Accurate Sensing of Speed Conditions on Rotating Shafts and Machinery

Ramsey Series Motion Monitoring Systems Accurate Sensing of Speed Conditions on Rotating Shafts and Machinery Ramsey Series 60-200 Motion Monitoring Systems Accurate Sensing of Speed Conditions on Rotating Shafts and Machinery Ramsey Series 60-200 Motion Monitoring Systems offer versatile and reliable packages

More information

Sentry LIQUID LEVEL GAUGE MODEL 200 or 200C OWNER MANUAL REV 1.7 SEPT08 PAGE 1 OF 12

Sentry LIQUID LEVEL GAUGE MODEL 200 or 200C OWNER MANUAL REV 1.7 SEPT08 PAGE 1 OF 12 PAGE 1 OF 12 TABLE OF CONTENTS PAGE 1. SAFETY PRECAUTIONS 1.1. Electrical shock 3 2. APPLICATION 3 3. INSTALLATION 3.1. Mount indoor alarm display 3.2. Mount the outdoor junction box 3.3. Install interconnecting

More information

ion Genesis Pump Controller

ion Genesis Pump Controller High Water Alarm Document No.: IONG_OM Page 1 of 7 Table of Contents Safety Precautions.......................... 1 General Overview.......................... 1 Installation.................................2

More information

5U Compact System. Installation Manual V1.0. Manufactured by Enatel Ltd. 321 Tuam Street PO Box Christchurch New Zealand

5U Compact System. Installation Manual V1.0. Manufactured by Enatel Ltd. 321 Tuam Street PO Box Christchurch New Zealand 5U Compact System Installation Manual V1.0 Manufactured by Enatel Ltd. 321 Tuam Street PO Box 22-333 Christchurch New Zealand Phone +64-3-366-4550 Fax +64-3-366-0884 Email sales@enatel.net www.enatel.net

More information

Quick-Start Operating Guide Document No Acrylic Vacuum Chambers Copyright 2010 Terra Universal Inc. All rights reserved. Revised October 2010

Quick-Start Operating Guide Document No Acrylic Vacuum Chambers Copyright 2010 Terra Universal Inc. All rights reserved. Revised October 2010 Document No. 1800-60 Acrylic Vacuum Chambers Copyright 2010 Terra Universal Inc. All rights reserved. Revised October 2010 Terra Universal, Inc. TerraUniversal.com 800 S. Raymond Ave. Fullerton, CA 92831

More information

Please Read And Save These Instructions.

Please Read And Save These Instructions. RadonAway Ward Hill, MA XP/GP/XR Series Fan Installation Instructions Please Read And Save These Instructions. DO NOT CONNECT POWER SUPPLY UNTIL FAN IS COMPLETELY INSTALLED. MAKE SURE ELECTRICAL SERVICE

More information

PO Box 827 Hawley, MN (218) Fax (218)

PO Box 827 Hawley, MN (218) Fax (218) Introduction Before proceeding with the installation or operation of the Oil Alert System, read all instructions thoroughly, as well as complying with all Federal, State and Local codes, Regulations and

More information

Installation, Operation & Service Manual

Installation, Operation & Service Manual Installation, Operation & Service Manual WARNING Improper installation, adjustment, alteration, service or maintenance can result in death, injury or property damage. Read the Installation, Operation and

More information

Model AV1LED Audio-Visual LED Light Installation and Maintenance Manual

Model AV1LED Audio-Visual LED Light Installation and Maintenance Manual Model AV1LED Audio-Visual LED Light Installation and Maintenance Manual 2561528A REV. A 810 Printed in U.S.A. Warranty Seller warrants all goods for five years on parts and 2-1/2 years on labor, under

More information

Ion Genesis II Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

Ion Genesis II Pump Controller Digital Level Control with Pump Alternation and High Water Alarm Page 1 of 8 General Overview Thank you for purchasing an Ion Genesis controller. Take the time to read the instructions carefully before using this appliance. We strongly recommend that you keep this instruction

More information

MIGHTY PRO 1/4 HP CHILLER

MIGHTY PRO 1/4 HP CHILLER 1 MIGHTY PRO 1/4 HP CHILLER FOR TANKS UP TO 170 GALLONS TOP QUALITY & HIGHLY EFFICIENT INTEGRATED DUAL STAGE THERMOSTAT 2 ASSEMBLY PARTS FRONT TOP VIEW BACK 3 SET UP INSTRUCTIONS 1. Remove chiller and

More information

CPL Series Pedestal Convection Heater

CPL Series Pedestal Convection Heater Installation Instructions and RENEWAL PARTS IDENTIFICATION CPL Series Pedestal Convection Heater MODEL CPLAS (H=5-1/2, D=3 ) CAT. LENGTH WATTS/ TOTAL AMPERAGE NO.* L Ft. WATTS 120V 208V 240V 277V 2125

More information

SUNCOURT INSTALLATION INSTRUCTIONS RADON FAN MODEL: RDKO4, RDK04-3, RDN04 & RDN04-3

SUNCOURT INSTALLATION INSTRUCTIONS RADON FAN MODEL: RDKO4, RDK04-3, RDN04 & RDN04-3 SUNCOURT INSTALLATION INSTRUCTIONS RADON FAN MODEL: RDKO4, RDK04-3, RDN04 & RDN04-3 READ THESE INSTRUCTIONS BEFORE PLANNING YOUR INSTALLATION PLEASE READ AND SAVE THESE INSTRUCTIONS: DO NOT CONNECT POWER

More information

SPA BLOWER OWNER'S MANUAL XXXX, XXXX, XXXX, XXXX, XXXX, XXXX fax

SPA BLOWER OWNER'S MANUAL XXXX, XXXX, XXXX, XXXX, XXXX, XXXX fax SPA BLOWER OWNER'S MANUAL 80015-XXXX, 80016-XXXX, 80017-XXXX, 80018-XXXX, 80019-XXXX, 80020-XXXX fax 888.610.3839 2015 323300-015 6/15 THIS PAGE INTENTIONALLY LEFT BLANK. 2 Operating Instructions and Parts

More information

INSTALLATION AND OPERATION MANUAL ISM-4081 INTEGRATED SHUTDOWN MODULE

INSTALLATION AND OPERATION MANUAL ISM-4081 INTEGRATED SHUTDOWN MODULE INSTALLATION AND OPERATION MANUAL ISM-4081 INTEGRATED SHUTDOWN MODULE SYSTEM CONCEPT When not transferring fuel, the pressure in the underground piping system for gasoline distribution may fall due to

More information

STOP. SAFETY INFORMATION Please read and understand this entire manual before attempting to assemble, operate or install the product.

STOP. SAFETY INFORMATION Please read and understand this entire manual before attempting to assemble, operate or install the product. STOP Power supply required Questions, problems, missing parts? Before returning to your retailer, call our customer service department at 1-800-742-5044, 7:30 a.m. - 5 p.m., EST, Monday - Friday. 115 volts

More information

SAFETY, OPERATION AND MAINTENANCE MANUAL. MX-1408 SELF-CONTAINED EXTRACTOR This unit is intended for commercial use.

SAFETY, OPERATION AND MAINTENANCE MANUAL. MX-1408 SELF-CONTAINED EXTRACTOR This unit is intended for commercial use. SAFETY, OPERATION AND MAINTENANCE MANUAL MX-1408 SELF-CONTAINED EXTRACTOR This unit is intended for commercial use. READ & FOLLOW ALL INSTRUCTIONS, WARNINGS & CAUTIONS BEFORE USING THIS EXTRACTOR This

More information

Disposal Unit (BKSDU) Burger King Shortening. Operation, Service & Parts Manual BURGER KING BKSDU

Disposal Unit (BKSDU) Burger King Shortening. Operation, Service & Parts Manual BURGER KING BKSDU BURGER KING BKSDU Burger King Shortening Disposal Unit (BKSDU) Operation, Service & Parts Manual Frymaster, a member of the Commercial Food Equipment Service Association, recommends using CFESA Certified

More information

SiteSentinel itouch Console

SiteSentinel itouch Console SITESENTINEL ITOUCH CONSOLE SiteSentinel itouch Console OPW s SiteSentinel itouch is a multifunction, high-quality tank-monitoring system that provides real-time, accurate inventory information for up

More information

SSS BPV- 40 Backpack Vacuum

SSS BPV- 40 Backpack Vacuum SSS BPV- 40 Backpack Vacuum Manual The contents of this manual are based on the latest product information available at the time of publication. Triple S reserves the right to make changes or improvements

More information

DL423 DirectLine Sensor Module for Conductivity Measurement Specifications

DL423 DirectLine Sensor Module for Conductivity Measurement Specifications DL423 DirectLine Sensor Module for Conductivity Measurement Specifications 70-82-03-47 January 2003 Overview DirectLine DL423 for Conductivity measurement is a family of sensors released by Honeywell as

More information