Emergi-Lite Orbis detectors

Size: px
Start display at page:

Download "Emergi-Lite Orbis detectors"

Transcription

1 Emergi-Lite Orbis detectors Emergi-Lite Orbis brings the latest in fire detector microprocessor technology to the Firetec and Eurofire systems. Non-addressable (conventional) smoke and heat sensors respond to fire situations within a given zone, sending a signal to the fire panel, which will indicate a fire condition and sound the alarm. Orbis provides valuable core features, with high reliability, a marked reduction in unwanted false alarms, complemented by operational and maintenance enhancements. Features: StartUp: Correct installation a flashing red LED Continuity link: Zone wiring can be voltage tested before commissioning Wide-angle optics: Responsive to fires with black or white smoke Drift Compensation: Calibrated sensitivity levels are maintained despite contamination DustDefy: Dust ingress prevented while airflow is unimpeded Transient Rejection: Abnormal readings are filtered out to reduce false alarms DirtAlert: A flashing yellow LED will indicate when the drift compensation limit has been reached SensAlert: A flashing yellow LED indicates incorrect sensor operation Fast Test: A 4 second test confirms correct detector operation E-Z Fit slots: Remove and refit the base without dismounting the fixing screws Detector base with diode FAPO-TDB The standard detector base has a diode fitted beneath the connectors. A link feature enables voltage testing of zone wiring before commissioning. The base is a five terminal unit positive IN, positive OUT, Negative IN & OUT, remote LED negative and functional earth (screen) wire. Two fixing centre positions are provided at 51 and 60mm. Connectors accept up to 2.5mm 2 cables Dimensions ø d (mm) 100 x FAPO-TDB Detector relay base FAPO-TRB The relay base has a single pole voltage free changeover contact for use to switch ancillary equipment. When the detector goes to alarm the relay is energised and changes state. Contacts rated at 30Vdc, 1A. Connectors accept up to 2.5mm 2 cables Dimensions ø d (mm) 100 x FAPO-TRB 57 Emergi-Lite Orbis detectors Conventional

2 Emergi-Lite Orbis detectors Optical smoke detector FAPO-OPT The optical detector measures the level of smoke particles using light scatter, going to alarm at a pre-set threshold. New optics help reduce false alarms while stability is strengthened by using internal software control. Recommended for general purpose use to give early warning of fire. FAPO-OPT Average quiescent current at 24V 65µA Alarm current at 12V 24V Dimensions ø d (mm) Vdc 20mA 40mA 97 x 31 (100 x 46 inc base) 75, 135 with base Standards EN54-7: 2000 Optical smoke and thermally enhanced detector FAPO-MUS The detector uses optical and heat sensing technology in deciding when to trigger an alarm condition. The unit is designed as a smoke detector and cannot be switched from smoke to heat detection. This detector is more sensitive to fast burning, flaming fires than the optical model. Ideal for where heat is prevalent at an early stage in the fire. FAPO-MUS Average quiescent current at 24V 65µA Alarm current at 12V 24V Dimensions ø d (mm) Vdc Standards EN54-7: mA 40mA 97 x 42 (100 x 57 inc base) 80, 140 with base 58 Conventional Emergi-Lite Orbis detectors

3 Emergi-Lite Orbis detectors Heat detectors Fixed temperature FAPO-HR1, FAPO-HR2, FAPO-HR3 The fixed (static) heat detector will trigger when a pre-set upper temperature threshold is exceeded at the sensor. Classification maximum application temperature: HR1 = 50ºC, HR2 = 65ºC, HR3 = 80ºC Average quiescent current at 24V 65µA Alarm current at 12V 24V Vdc 20mA 40mA Dimensions ø d (mm) 100 x Standards EN54-5: 2000 FAPO-HR1 STANDARD ORDER CODE FAPO-HR1 FAPO-HR2 FAPO-HR3 DESCRIPTION Heat detector Fixed upper threshold 50ºC, A2S Heat detector Fixed upper threshold 65ºC, BS Heat detector Fixed upper threshold 80ºC, CS Heat detectors Rate of rise FAPO-RR1, FAPO-RR2, FAPO-RR3 The heat detector will monitor the rate of temperature increase in the vicinity and will also be triggered when a fixed upper threshold temperature level is exceeded. Readings are taken every 2 seconds, the stored values are compared against a preset value to decide if an alarm level has been reached. Classification maximum application temperature: RR1= 50ºC, RR2 = 65ºC, RR3 = 80ºC Average quiescent current at 24V 65µA Alarm current at 12V 24V Dimensions ø d (mm) Vdc Standards EN54-7: mA 40mA 97 x 36 (100 x 51 inc base) 70, 130 with base FAPO-RR1 STANDARD ORDER CODE FAPO-RR1 FAPO-RR2 FAPO-RR3 DESCRIPTION Heat detector -Rate of rise with fixed upper threshold 50ºC, A1R Heat detector -Rate of rise with fixed upper threshold 65ºC, BR Heat detector -Rate of rise with fixed upper threshold 80ºC, CR 59 Emergi-Lite Orbis detectors Conventional

4 Conventional 4-wire detectors Conventional 4-wire detection: The FAP6 range Introducing the FAP6 range of detectors, for use with the Firetec and Eurofire 4-wire panels. FAP6 provides proven technology in a slim package, the concise range comprises optical and heat detectors (fixed and rate of rise temperature). In conjunction with Firetec the range is suited to small to medium sized buildings. Detector base with diode FAP6-STB The standard detector base has a diode fitted beneath the connectors. Connectors accept up to 2.5mm 2 cables Dimensions ø d (mm) 100 x FAP6-STB Relay base FAP6-RLB The relay base incorporates a set of volt-free changeover contacts, which will latch when the detector registers an alarm. FAP6-RLB 9 33Vdc Relay base alarm current at 24V 17mA Modes Latching -20 to +70ºC Connectors accept up to 2.5mm 2 cables Dimensions ø d (mm) 100, FAP6 is based on series 65 technology from Apollo Fire Detectors Ltd Conventional Conventional 4-wire detectors

5 Conventional 4-wire detectors Relay base, 12 volt FAP6-RLB12 The low voltage relay base incorporates a set of volt-free changeover contacts that can be used for either latching or non-latching (security system) purposes. To enable control of an automatic door closer, for example. 9 15Vdc Average quiescent current at 12V <10µA Relay base alarm current, at 12V 20mA Modes Latching or non-latching 20 to +70ºC Connectors accept up to 2.5mm 2 cables Dimensions ø d (mm) 100, FAP6-RLB12 Optical smoke detector FAP6-OPT The optical detector measures the level of smoke particles using light scatter, going to alarm at a pre-set threshold. New optics help reduce false alarms while stability is strengthened by using internal software control. Recommended for general purpose use to give early warning of fire Vdc Average quiescent current at 24V 65µA Alarm current at 12V 24V Alarm indication Dimensions ø d (mm) Standards EN54-7: mA 40mA Clear LED, red on alarm -20 to +60ºC 100 x 42 (100 x 50 inc base) 99, 150 with base FAP6-OPT 61 Conventional 4-wire detectors Conventional

6 Conventional 4-wire detectors Heat detector fixed temperature FAP6-FT8 The fixed (static) heat detector will trigger when a pre-set upper temperature threshold is exceeded at the sensor. FAP6-FT8 Quiescent current at 24V Alarm current at 9V 24V Alarm indication Dimensions ø d (mm) 9 33Vdc <50µA 17mA 52mA Red LED 20 to +90ºC 100 x 42 (100 x 50 inc base) 80, 131 with base Standards EN54-5: 2000 Heat detector Rate of rise FAP6-RR6, FAP6-RR75, FAP6-RR90 The heat detector will monitor the rate of temperature increase in the vicinity and will also be triggered when a fixed upper threshold temperature level is exceeded. Classification maximum application temperature: RR6= 50ºC, RR75 = 65ºC, RR90 = 80ºC FAP6-RR6 9 33Vdc Quiescent current at 24V <50µA Alarm current at 9V 24V 17mA 52mA Alarm indication Red LED 20 to +90ºC Dimensions ø d (mm) 100 x 42 (100 x 50 inc base) 80, 131 with base Standards EN54-7: 2000 STANDARD ORDER CODE FAP6-RR6 FAP6-RR75 FAP6-RR90 DESCRIPTION Heat detector Rate of rise with fixed upper threshold 50ºC, A1R Heat detector Rate of rise with fixed upper threshold 65ºC, BR Heat detector Rate of rise with fixed upper threshold 80ºC, CR 62 Conventional Conventional 4-wire detectors

7 Conventional 4-wire call points Call point FMC-200R Surface mounted manually operated call point with LED indicator, providing a switch closure to the panel when operated. Features: Secure clip-fix front cover A single key for test, reset and removal of cover 24Vdc Impedance 470R series resistor Alarm indication Red LED -25 to +55ºC 4 way terminal block ABS plastic in red IP42 Dimensions lwd (mm) 87 x 87 x 53 (20 without back box) 190 Standards EN54-11 OPTIONS FMC-200RS Call point with re-settable plastic element FMC-10G Spare glass (pack of 10) FMC-10GRS Spare re-settable element (pack of 10) FMC-200R RSL800 Weatherproof call point FMC-200RWP Surface mounted manually operated call point with LED indicator, providing a switch closure to the panel when operated. Features: Secure clip-fix front cover One key for test, reset and removal of cover Weatherproof to IP67 24Vdc Impedance 470R series resistor Alarm indication Red LED 25 to +55ºC 4 way terminal block ABS plastic in red IP67 Dimensions lwd (mm) 110 x 110 x Standards EN54-11 OPTION FMC-200RSWP Weatherproof call point with re-settable plastic element FMC-200RWP ACCESSORIES FOR FMC CALL POINTS FMC-KEY Spare test key (pack of 10) FMC-10G Spare glass (pack of 10) FMC-10GRS Spare re-settable element (pack of 10) FMC-PC Polycarbonate cover FMC-PCS Polycarbonate cover with security tie RSL800 Fire call point notice sticker SPARES FOR FMC INDOOR CALL POINTS FMC-BBR Back box in red FMC-BBW Back box in green For standard and weatherproof protective call point covers, see page Conventional 4-wire call points Conventional

8 Conventional 4-wire call points Call point FMC-800R Surface mounted manually operated call point, providing a switch closure to the panel when operated. Features: Secure clip-fix front cover A single key for test, reset and removal of cover FMC-800R 24Vdc Impedance 470R series resistor 25 to +55ºC 4 way terminal block ABS plastic in red IP42 Dimensions lwd (mm) 87 x 87 x 53 (20 without back box) 190 Standards EN54-11 OPTION FMC-800RS Call point with re-settable plastic element RSL800 Weather resistant call point FMC-800RWP Surface mounted manually operated call point, providing a switch closure to the panel when operated. Features: Secure clip-fix front cover One key for test, reset and removal of cover Weatherproof to IP67 FMC-800RWP 24Vdc Impedance 470R series resistor 25 to +55ºC 4 way terminal block ABS plastic in red IP67 Dimensions lwd (mm) 110 x 110 x Standards EN54-11 OPTION FMC-800RSWP Weatherproof call point with re-settable plastic element 64 For standard and weatherproof protective call point covers, see page 88. ACCESSORIES FOR FMC CALL POINTS FMC-KEY Spare test key (pack of 10) FMC-10G Spare glass (pack of 10) FMC-10GRS Spare re-settable element (pack of 10) FMC-PC Polycarbonate cover FMC-PCS Polycarbonate cover with security tie RSL800 Fire call point notice sticker SPARES FOR FMC INDOOR CALL POINTS FMC-BBR Back box in red FMC-BBW Back box in green Conventional Conventional 4-wire call points

9 Conventional 4-wire call points/ancillary Key-switch operated call point FMC-2KSW A key-switch operated call point for use in secure premises where restricted access is needed. Suitable for use with 230Vac systems Operation 24Vdc Switch rating 10A, 24Vdc 2A, 230Vac 2 position keyswitch with 1 NO contact and 1 NC contact 25 to +55ºC Flying lead connections ABS plastic in red Dimensions lwd (mm) 87 x 87 x Standards Fitting IP42, when fitted to a standard back box EN54-11 The 2KSW can be used with either a standard or a weather resistant back box. FMC-2KSW Remote Indicator unit FAP6-P10 A remote indicator is used to help an investigator quickly identify the location where a device has registered a fire, without having to gain entry to every room or inaccessible space. Features: Fire detector operated text LED indicator Red Terminal block IP rating IP42 Dimensions lwd (mm) 86.5 x 86.5 x 9 38 FAP6-P10 o Closed room space o Normal detection: Indicator visible Zone+ L1 in L1 out - R L1 in L1 out End of line device - R Zone +ve Zone -ve Remote LED indicator IN+ OUT+ LED- COM- LED- COM- IN+ OUT+ EOL Zone Corridor Solid door Vision panel in door Remote indicator Zone - Earth Note: A diode is normally fitted between L1 in & L1 out L2 L2 Note: A diode is normally fitted between IN+ & OUT- Example: Connecting a remote indicator to an FAP6 detector base (shown common across two detectors) in a zone Connection of remote LED unit to FAPO Orbis detector Illustration: Use of remote indicator in conventional fire system Ceiling tile mounting box FAP-MBCT The fixture is used to fit a detector or sounder into a false ceiling matrix. The devices can be pre-wired and tested before the ceiling is fitted. With the ceiling tiles in place, the MBCT assemblies can be slotted into place. STANDARD ORDER CODE FAP-MBCT-FD FAP-MBCT-SO DESCRIPTION Ceiling tile mounting box for detectors Ceiling tile mounting box for sounders 65 FAP-MBCT-FD Conventional 4-wire call points/ancillary Conventional

10 Conventional 4-wire alarms FACS Conventional 4-wire sounders, beacons and alarm bells Emergi-Lite Safety Systems offers a range of sounder and alarm options, for use with Firetec and Eurofire 4-wire panels. The table below highlights the key features of individual alarms to assist with planning and selection, when preparing a fire detection and evacuation system. PRODUCT CODE DESCRIPTION Features: Bell 6in diam Beacon Sounder Sounder: room / bedhead Sounder beacon Amber, Clear or Red lens Red. White or Grey body Visual LED IP rating 100 db(a) Integrated base Accessories 32 Tone range Page reference FACS-5W Sounder base W 67 FACS-5TPR Sounder base cap R 67 FACS-5TPW Sounder base cap W 67 FACS-1R Sounder R 67 FACS-1RL Sounder R 67 FACS-1W Sounder W 67 FACS-1WL Sounder W 67 FACS-BBR Back box for FACS1R R 67 FACS-BBW Back box for FACS1W W 67 FACS-4R Sounder R 68 FACS-4RDB Sounder R FACS-4W Sounder W 68 FACS-4WDB Sounder W FACS-8R Sounder-beacon R R 68 FACS-8RDB Sounder-beacon R R FACS-8RDB-A Sounder-beacon A R FACS-8W Sounder-beacon R W 68 FACS-8WDB Sounder-beacon R W FACS-BEA-R Beacon R R 69 FACS-BEA-RDB Beacon R R FACB-624 Bell R 69 FACB-624-G Bell G 69 FAAB-624-WP Bell R Conventional Conventional 4-wire alarms

11 Conventional 4-wire alarms Low profile sounder FACS-5W A low height sounder that can be used standalone with an optional cover or as a platform for a smoke/heat detector with a detector base. Features: Four selectable tones including warble, pips and sweep 8 35Vdc Current 24Vdc 11mA Sound output, at 1m (dba) 91 (94 with cover plate) No. of tones 4 Operating frequency 800Hz to 1Khz 20 to +70ºC Terminal block Cable entry Rear ABS plastic IP43 (DB version - IP65) Dimensions ø h (mm) 106 x 25 (35 with cover) 121 OPTIONS FACS-5TPW White cover FACS-5TPR Red cover FACS-5W FACS-5TPW Room sounder FACS-1R A room sounder, suitable for bedroom and passageway use. Features: Low profile with a small footprint Audio/visual version with flashing LEDs on alarm Four selectable tones including warble, pips and sweep 8 35Vdc Current 24Vdc 11mA Sound output, at 1m (dba) 97 No. of tones 4 Volume control -50dBA Operating frequency 800Hz to 1Khz -20 to +70ºC Terminal block Cable entry Rear (or side entry with surface box) ABS plastic IP43 Dimensions lwd (mm) 86.5 x 86.5 x 9 (+25.2 back box or recessed) 103 OPTIONS FACS-1RL Room sounder, red, with two flashing hi-intensity LEDs FACS-1W Room sounder, white FACS-1WL Room sounder, white, with two flashing hi-intensity LEDs FACS-BBR Back box for FACS-1R FACS-BBW Back fox for FACS-1W FACS-1R 67 Conventional 4-wire alarms Conventional

12 Conventional 4-wire alarms Open area sounder FACS-4R A multi-tone sounder for open area use, operating across a range of frequencies. Features: Quick fit installation 32 tones, selectable by DIL switch High, medium and low outputs can be selected to fit in with a local sound pattern requirement Side grub screw for security locking FACS-4R FACS-4RDB 15 35Vdc Sound level Low Med Hi Current 24Vdc <9mA <18mA <36mA Sound output, at 1m, 1st tone (dba) No. of tones 32 Operating frequency 440 to 2900Hz 20 to +70ºC Terminal block Cable entry Rear (DB rear or side entry [with cover plate]) ABS plastic IP43 (DB version - IP65) Dimensions ø h (mm) 93.6 (DB-93) x 84.3 (DB-101.6) 220 (DB-250) OPTIONS FACS-4RDB Open area sounder, red, deep base FACS-4W Open area sounder, white, shallow base FACS-4WDB Open area sounder, white, deep base 68 FACS-8R FACS-8RDB Open area sounder beacon FACS-8R A multi tone sounder-beacon, for open area use. Features: LED cluster beacon light 32 tones, selectable by DIL switch Enables compliance with the Disability Discrimination Act (DDA) Side grub screw for security locking 15 35Vdc Sound level Low Med Hi Current 24Vdc <14mA <20mA <41mA Sound output, at 1m, 1st tone (dba) No. of tones 32 Operating frequency 440 to 2900Hz 20 to +70ºC Terminal block Cable entry Rear (DB rear or side entry [with cover plate]) ABS plastic, with red lens IP43 (DB version IP65) Dimensions ø h (mm) 93.6 (DB-93) x 89.6 (DB-106.9) 233 (DB-258) OPTIONS FACS-8RDB Open area sounder, red, deep base FACS-8W Open area sounder, white, shallow base FACS-8WDB Open area sounder, white, deep base FACS-8RDB-A Open area sounder, red, deep base with amber cover Conventional Conventional 4-wire alarms

13 Conventional 4-wire alarms Alarm beacon FACS-BEA-R A bright output flashing beacon to augment sounders, particularly in areas of higher ambient noise. LED light source with low power requirement Vdc Set up Standard Low Current 24Vdc 5mA 3mA Light output 0.7w 0.4w Operating frequency 1Hz 20 to +70ºC 6 way angled terminal block Cable entry Rear (DB - rear or side entry) ABS plastic in red IP43 (DB version - IP65) Dimensions ø h (mm) 93.6 (DB-93) x 60.2 (DB-77.1) 145 OPTION FACS-BEA-RDB Alarm beacon, deep base FACS-BEA-R FACS-BEA-RDB Alarm fire bell FACB-624 A wall mountable motorised fire bell for fire alarm or class change. The gong is secured by a tamper resistant bolt Vdc Current 24Vdc 25mA Sound output, at 1m (dba) to +55ºC 4 way terminal block Cable entry Rear (or side entry with surface box) Metal gong in red IP42 Dimensions ø h (mm) 150 x OPTION FACB-624-G Alarm fire bell with grey gong FACB Conventional 4-wire alarms Conventional

14 Conventional 4-wire alarms Alarm fire bell FAAB-624-WP A wall mountable fire bell for fire alarm or class change applications. Weather resistant rating achieved with a rubber gasket. FAAB-624-WP 18 30Vdc Current 24Vdc 30mA Sound output, at 1m (dba) to +55ºC 4 way terminal block Cable entry Rear (or side entry with surface box) Metal gong in red, base in polycarbonate IP55 Dimensions ø h (mm) 150 x 85 1, Conventional Conventional 4-wire alarms

optical detector multisensor detector heat detector mounting bases product guide

optical detector multisensor detector heat detector mounting bases product guide optical detector multisensor detector heat detector mounting bases product guide ...conventional detectors from Apollo orbis is a range of conventional detectors which has been developed and tested to

More information

ORBIS PRODUCT GUIDE. Optical Detector. Multisensor Detector. Heat Detector. Mounting Bases

ORBIS PRODUCT GUIDE. Optical Detector. Multisensor Detector. Heat Detector. Mounting Bases PRODUCT GUIDE Optical Detector Multisensor Detector Heat Detector Mounting Bases 2...conventional detectors from Apollo orbis is a range of conventional detectors which has been developed and tested to

More information

CONTENTS NBM-06 Bell (6") Page 1

CONTENTS NBM-06 Bell (6) Page 1 CONTENTS NBM-06 Bell (6") - - - Page 1 NBM-08 Bell (8") - - - Page 1 LFB-24 Sounder Banshee - Page 2 VCT--NT Base Version Sounder Page 2 VCT--NT Wall Version Sounder Page 2 VRS1-R or W Bedhead Sounder

More information

Series 65 Product Guide MAN 3036

Series 65 Product Guide MAN 3036 Series 65 Product Guide MAN 3036 TABLE OF CONTENTS Page No. 1 Ionisation Smoke Detector... 1 1.1 Operating Principles:... 1 1.2 Product Codes... 2 1.3 Integrating Version:... 2 1.4 Options:... 2 1.5 Safety

More information

EFBW series - BiWire Ultra control panel

EFBW series - BiWire Ultra control panel 4.2 Control panels and repeater panels EFBW series - BiWire Ultra control panel Eaton s new BiWire Ultra fire detection system is unlike any other standard conventional system as the panel, conventional

More information

4 wire conventional alarm system

4 wire conventional alarm system Scimitar 4 wire conventional alarm system from Channel Safety Systems Scimitar 4 wire conventional alarm system The Scimitar Fire Alarm Control System is a comprehensive range of high specification conventional

More information

System 800 Addressable Fire Detection & Alarm System

System 800 Addressable Fire Detection & Alarm System SECTION 5: page 1 Section 5: System 800 Addressable Fire Detection & Alarm System SECTION 5: page 3 10 reasons to specify 800 1 Plug and Play A user friendly panel not requiring special software tools

More information

The new detector from Rafiki

The new detector from Rafiki The new detector from Rafiki Three smoke detectors Three heat detectors Combined smoke/heat detector Full alarm sounder Strobe End-of-line device/loop isolator Rafiki s Multipoint ASD detector range have

More information

Conventional Smoke Detectors KFAPO

Conventional Smoke Detectors KFAPO Kingfisher Company, inc. Conventional Smoke Detectors KFAPO Features: Wide operating voltage, 9-33 VDC Advanced electronic technology Flashing LED Magnetic test switch Proven detection performance Designed

More information

Analogue addressable devices

Analogue addressable devices Apollo XP95 Analogue addressable devices from Channel Safety Systems Apollo XP95 Analogue addressable devices The XP95 range of analogue addressable fire detectors is advanced in design, improved in performance

More information

Conventional Fire Detection

Conventional Fire Detection SECTI 4: page 1 Section 4: Conventional Fire Detection Contents System Architecture Control Panel Automatic & Manual Detection Manual Call Points Smoke Detectors Heat Detectors Beam Smoke Detectors Duct

More information

Evolution Analogue Addressable Fire System

Evolution Analogue Addressable Fire System Addressable Fire System optimum fire safety systems solutions High speed FSK protocol, uniquely resistant to noise Up to 254 addresses per loop for flexible system design Built to exceptional marine standards

More information

VIMPEX BS Evacuation. Fire Alarms EN Banshee. Beacons. FlashDome. Electronic Sounders. Audible Alarm

VIMPEX BS Evacuation. Fire Alarms EN Banshee. Beacons. FlashDome. Electronic Sounders. Audible Alarm VIMPEX Sounder Range Fire Alarms Banshee Electronic Sounders FlashDome EN 54-3 Evacuation Audible Alarm BS 5839-1 Beacons The range of sounders, beacons, sounder beacons and accessories represents the

More information

Industries. As a premier global manufacturing company, we believe that great brands are

Industries. As a premier global manufacturing company, we believe that great brands are JSB Fire Systems ONE COOPER Every day, thousands of people all over the world use products made by Cooper Industries. As a premier global manufacturing company, we believe that great brands are built on

More information

SERIES 65 ENGINEERING PRODUCT GUIDE

SERIES 65 ENGINEERING PRODUCT GUIDE SERIES 65 ENGINEERING PRODUCT GUIDE Wide Voltage Conventional Detectors Series 65 incorporates well-proven sensing technologies, including an Integrated Circuit based on that used in XP95 analogue addressable

More information

The complete conventional fire warning system

The complete conventional fire warning system The complete conventional fire warning system www.espuk.com MAG2P 2 Zone Fire Panel 2 programmable zones Active end of line monitoring and head removal 30 fire detectors per zone Unlimited number of call

More information

OPERATION AND INSTALLATION MANUAL

OPERATION AND INSTALLATION MANUAL EX+Plus 2 ZONE, 1AREA EXTINGUISHANT CONTROL PANEL OPERATION AND INSTALLATION MANUAL INTRODUCTION The Premier EX Plus is a 2 zone, single area panel for controlling the release of extinguishing gases in

More information

Optical Smoke Detector Heat Detector Manual Call Point Output Unit Isolator

Optical Smoke Detector Heat Detector Manual Call Point Output Unit Isolator TECHNICAL GUIDE Optical Smoke Detector Heat Detector Manual Call Point Output Unit Isolator The XPlorer Range XPlorer is a new range of analogue addressable detectors and interfaces developed for all who

More information

Cooper Industries (UK) Ltd

Cooper Industries (UK) Ltd Menvier Fire Systems Powering business worldwide As a globall diversified power management company, we help customers worldwide manage the power needed for buildings, aircraft, trucks, cars, machinery

More information

OH110, OP110, HI110 Automatic fire detectors

OH110, OP110, HI110 Automatic fire detectors OH110, OP110, HI110 Automatic fire detectors For collective and conventional detector lines Signal processing with detector algorithms Selectable parameter sets 3 color LED indication Drift compensation

More information

Intellia Sounder Bases and Sounder Beacon Bases

Intellia Sounder Bases and Sounder Beacon Bases Intellia Bases and Beacon Bases The Base and Beacon Base are a local-area alarm devices designed for indoor use. They can be connected only to detection systems using Intellia detectors and FX control

More information

BT1 SINGLE ZONE FIRE ALARM SYSTEM OPERATORS MANUAL

BT1 SINGLE ZONE FIRE ALARM SYSTEM OPERATORS MANUAL BT1 SINGLE ZONE FIRE ALARM SYSTEM OPERATORS MANUAL 26 Aug 2015 V1.8 Page 1 SECTION CONTENTS PAGE NO. 1.0 SYSTEMS DESCRIPTION 1.1 General descriptions 2 1.2 Master Alarm PCB 2 1.3 Zone Display Board 2 1.4

More information

ED820-24V MODEL INSTRUCTION MANUAL. fire DETECTOR

ED820-24V MODEL INSTRUCTION MANUAL. fire DETECTOR ED820 24V MODEL fire DETECTOR INSTRUCTION MANUAL Address: Enigma House, Enigma Business Park, Malvern, Worcestershire, WR14 1GD Tel: 44 (0)1684 891500 Fax: 44 (0)1684 891600 Email: sales@electronicdevices.co.uk

More information

Xenex Conventional Fire Detection & Alarm System

Xenex Conventional Fire Detection & Alarm System SECTI 4: page 1 Section 4: Xenex Conventional Fire Detection & Alarm System SECTI 4: page 3 Xenex system architecture Beam Transmitter Beam Receiver End of Line Call Point Smoke Detector Smoke Detector

More information

Conventional Fire Control Panel (FKEP2, FKEP4, FKEP8) Operation and Maintenance Manual. Man-1078EL Issue 01 February 2014

Conventional Fire Control Panel (FKEP2, FKEP4, FKEP8) Operation and Maintenance Manual. Man-1078EL Issue 01 February 2014 Conventional Fire Control Panel (FKEP2, FKEP4, FKEP8) Operation and Maintenance Manual Man-1078EL Issue 01 February 2014 B Index Page 1. Introduction... 3 1B2. Safety and mounting... 3 2B3. Technical specification...

More information

FIREPRO INSTALLATION MANUAL FIRE ALARM CONTROL PANEL INSTALLATION MANUAL. Approved Document No. GLT Issue: 1. 8 Author: NRPJ Date: 7/ 3/201 4

FIREPRO INSTALLATION MANUAL FIRE ALARM CONTROL PANEL INSTALLATION MANUAL. Approved Document No. GLT Issue: 1. 8 Author: NRPJ Date: 7/ 3/201 4 FIRE ALARM CONTROL PANEL INSTALLATION MANUAL Approved Document No. GLT -201-7-3 Issue: 1. 8 Author: NRPJ Date: 7/ 3/201 4 CONTENTS 1. INTRODUCTION... 1.1 HANDLING THE PCBS... 1.2 USING THIS MANUAL... 1.3

More information

Eaton is a global leader with expertise in:

Eaton is a global leader with expertise in: JSB Fire Systems P o w e ring business worldwide As a global l diversified power management company, we help customers worldwide manage the power n e e d e dfor buildings, aircraft, trucks, cars, machinery

More information

Installation, Operating and Maintenance Manual

Installation, Operating and Maintenance Manual STATUS ZONES CONTROLS FIRE FAULT DISABLED FIRE 1 2 3 4 5 6 7 8 TEST FAULT DISABLED 1 5 BUZZER SILENCE RESET 1 2 TEST 2 6 LAMP TEST 3 SUPPLY 3 7 SYSTEM FAULT 4 8 SOUNDERS ACTIVATE/ SILENCE 4 FAULTS INSTRUCTIONS

More information

Overview. Wireless Overview QLD NSW VIC Fundamentals. Operation. Features.

Overview. Wireless Overview QLD NSW VIC Fundamentals. Operation. Features. Wireless Overview www.incitefire.com.au Overview Fundamentals FIREwave is a wireless based family of products which is fully integrated into Hochiki s renowned ESP intelligent hardwired system. This seamless

More information

Fire-Cryer. Plus Application Guide APPLICATION GUIDE FIRE EXIT VIMPEX. Shaping Alarm Technology

Fire-Cryer. Plus Application Guide APPLICATION GUIDE FIRE EXIT VIMPEX. Shaping Alarm Technology Fire-Cryer Plus Application Guide APPLICATION GUIDE FIRE EXIT VIMPEX Shaping Alarm Technology Fire-Cryer Plus The Fire-Cryer range of voice sounders was first introduced to the market by Vimpex in 1999.

More information

Conventional Fire Control Panel

Conventional Fire Control Panel (FKEW Series) Conventional Fire Control Panel (FKEW2, FKEW4, FKEW8) Man-1138EL Issue 01 February 2014 Contents 1. Introduction... 4 2. Safety... 4 4. Technical specification... 5 5. Control panel fascia...

More information

Fire Product Catalog

Fire Product Catalog Additional Expansion Modules Fire Product Catalog CLEVER FIRE SOLUTIONS MA 1000 / Analog Addressable Fire Alarm Panel 1 Military Industry Public Buildings Industrial & Commercial Company Profile We are

More information

CONVENTIONAL >FIRE DETECTION C400 SYSTEM FIRE DETECTION

CONVENTIONAL >FIRE DETECTION C400 SYSTEM FIRE DETECTION FIRE DETECTION >FIRE DETECTION CONVENTIONAL C400 SYSTEM FIRE DETECTION EFFICIENT AND MODULAR Elkron fire detection systems protect your business and grow with it Elkron's conventional fire detection range

More information

NZ 400 AUTOMATIC FIRE ALARM SYSTEM OPERATORS MANUAL

NZ 400 AUTOMATIC FIRE ALARM SYSTEM OPERATORS MANUAL NZ 400 AUTOMATIC FIRE ALARM SYSTEM OPERATORS MANUAL Document No...G108WO1.DOC Serial No... Issue Date...17 th SEPTEMBER 1999 Software Version...1.4 APPROVED TO: NZS 4512:1997 AS/NZS 3548:1992 Fire Alarm

More information

Orbis IS Product Guide MAN 3041

Orbis IS Product Guide MAN 3041 Orbis IS Product Guide MAN 3041 TABLE OF CONTENTS Page No. 1 Introduction to Intrinsic Safety... 2 2 Range of Products... 3 3 Features of Orbis IS... 3 4 Choosing a Detector: Q & A... 3 5 Orbis IS Optical

More information

MINERVA MZX125 Digital Addressable Fire Detection System

MINERVA MZX125 Digital Addressable Fire Detection System DATASHEET MINERVA MZX125 Digital Addressable Fire Detection System The Minerva MZX125 is a highly featured digital addressable panel with a comprehensive but easy to operate user interface. The system

More information

Reflective Optical Beam Smoke Detector User Guide

Reflective Optical Beam Smoke Detector User Guide Reflective Optical Beam Smoke Detector User Guide 1. Installation IMPORTANT NOTE: The infrared beam path MUST be kept clear of obstructions at all times! Failure to comply may result in the system initiating

More information

Intelligent addressable fire alarm control panel

Intelligent addressable fire alarm control panel Intelligent addressable fire alarm control panel Input current consumption: Panel rating: Batteries: Networking and Interfaces Panel to panel communication: Number of panels: Interface port: System capacity

More information

Fireray Application and. Installation Guide FEATURES. Range metres. 12V to 24V dc operation. Selectable alarm thresholds

Fireray Application and. Installation Guide FEATURES. Range metres. 12V to 24V dc operation. Selectable alarm thresholds Fireray 2000 pplication and FETURES Installation Guide Range 10-100 metres 12V to 24V dc operation Selectable alarm thresholds Low current consumption Ground level electronics Manual or automatic reset

More information

Addressable Detectors & Bases

Addressable Detectors & Bases Edwards Signaling Catalog u Intelligent Initiating Addressable Detectors & Bases Detectors: E-PD, E-PHD, E-HD Bases: B4U, RB4U, IB4U, SB4U Overview Edwards intelligent addressable detectors are meticulously

More information

Syncro AS. Analogue Addressable Fire Control Panel. User Manual

Syncro AS. Analogue Addressable Fire Control Panel. User Manual Syncro AS Analogue Addressable Fire Control Panel User Manual Man-1100 Issue 02 Nov. 2008 Index Section Page 1. Introduction...3 2. Safety...3 3. Panel Controls...4 3.1 Access Level 1...4 3.2 Access Level

More information

Product Guide MAN7030-2

Product Guide MAN7030-2 MAN7030-2 Product Guide Ampac addressable range expansion Wireless Minimsies disruption to building and occupants Enables rapid retrofit or temporary solution AS4428-9 Dual batteries for enhanced integrity

More information

Conventional Audible Visual Range

Conventional Audible Visual Range Conventional Audible Visual Range Visual Devices Non-Addressable Audible Visual Devices Base Sounder Honeywell s conventional audible visual devices operate over a wide input voltage range of 9 to 33VDC

More information

HART XL High Sensitivity Smoke Detection

HART XL High Sensitivity Smoke Detection High Sensitivity Smoke Detection The Hart XL High Sensitivity Smoke Detection system (HSSD) is an aspirating fire detection system designed to give very early indication of an incipient fire condition.

More information

An introduction to... Sigma

An introduction to... Sigma An introduction to... Sigma XT+ Sigma XT+ Overview The Sigma XT+ 21000 series are the latest additions to the Sigma family of control equipment from Kentec Electronics Limited. The Sigma XT+ range combines

More information

Protec. Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System. Fire Detection - Addressable

Protec. Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System. Fire Detection - Addressable Protec Protec Fire Detection Pty Ltd Fire Detection - Addressable Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System ADDRESSING SAFETY SYSTEMS WITH INTELLIGENCE Fire Detection

More information

intelligent solutions

intelligent solutions Alco is one of the leading intelligent solution providers of Fire Detection System. Security System and Public Addressing System in the United States of America. Based in California since 1992, we have

More information

Addressable and Conventional Fire Protection

Addressable and Conventional Fire Protection Addressable and Conventional Fire Protection Simply reliable F I R E P R O T E C T I O N The MAGPro and Fireline systems has been created to balance performance, reliability and aesthetics whilst being

More information

FIRE ALARM CONTROL PANEL. COMPLIES WITH EN54 part 2 & part 4 MEETS THE FUNCTIONAL REQUIREMENT OF BS:EN 5839 part 1 INSTALLATION MANUAL

FIRE ALARM CONTROL PANEL. COMPLIES WITH EN54 part 2 & part 4 MEETS THE FUNCTIONAL REQUIREMENT OF BS:EN 5839 part 1 INSTALLATION MANUAL FIRE ALARM CONTROL PANEL COMPLIES WITH EN54 part 2 & part 4 MEETS THE FUNCTIONAL REQUIREMENT OF BS:EN 5839 part 1 INSTALLATION MANUAL CONTENTS 1. INTRODUCTION. 3 1.1 HANDLING THE PCBS 1.2 USING THIS MANUAL

More information

Conventional Leaflets

Conventional Leaflets Conventional Leaflets Panels Last updated October 1999 Make leaflet selection by clicking on appropriate bookmark Return to Menu Installation and Basic Commissioning guide for the range of 1,2,4 and 8

More information

FTEN1, FTEN2, & FTEN4 1, 2 & 4 ZONE FIRE DETECTION AND ALARM CONTROL PANELS

FTEN1, FTEN2, & FTEN4 1, 2 & 4 ZONE FIRE DETECTION AND ALARM CONTROL PANELS QUICK USER GUIDE FOR, 2 & 4 ZONE PANELS INDICATORS COLOUR INDICATION MON FAULT Yellow On when a fault condition has occurred, or if no other fault Led is on, this indicates 24v auxiliary fuse failure.

More information

SOUNDER BASES AND SOUNDER BEACON BASES

SOUNDER BASES AND SOUNDER BEACON BASES Tech Data Sheet D01513GB3 44/2011 Fire Detection SOUNDR BASS AND SOUNDR BACON BASS Intellia Sounder Bases and Sounder Beacon Bases The Sounder Base and Sounder Beacon Base are a local-area alarm devices

More information

CATALOGUE. Request to Exit Products Relays, Fuses & Timers TROJAN DEVELOPMENTS Product Catalogue.

CATALOGUE. Request to Exit Products Relays, Fuses & Timers TROJAN DEVELOPMENTS Product Catalogue. CATALOGUE 2018 Product Catalogue Request to Exit Products Relays, Fuses & Timers CONTENTS Table of Contents Introduction: 3 Request & Emergency Egress Devices: Prox Rex 4 Press Rex 5 Em Rex 6 Smart Em

More information

Control Panel Engineering and Commissioning Instructions

Control Panel Engineering and Commissioning Instructions Twinflex - V3 Fire Detection & Alarm System Control Panel Engineering and Commissioning Instructions (TO BE RETAINED BY THE COMMISSIONING ENGINEER) 26-0338 Issue 9 Fike s policy is one of continual improvement

More information

Fire Signalling. Signalling Solutions

Fire Signalling. Signalling Solutions Fire Signalling Signalling Solutions Introduction Introduction Klaxon Signals manufactures the world s largest range of sound signalling equipment and solutions for the European and worldwide market place.

More information

Saffire User & Installation Manual. IMPORTANT This manual should be left with the panel after installation.

Saffire User & Installation Manual. IMPORTANT This manual should be left with the panel after installation. Saffire+ 8-12 User & Installation Manual IMPORTANT This manual should be left with the panel after installation. We reserve the right to change product specifications without prior notice. Copyright VRC

More information

LF-4000 Series Conventional Fire Alarm Control Unit

LF-4000 Series Conventional Fire Alarm Control Unit LF-4000 Series Conventional Fire Alarm Control Unit Features: 1 to 36 Zone Control Panels Control Key Switch Easy Push Button Control Switches Zone Circuit Monitoring for Open and Short Sounder Circuit

More information

ELECTRONIC SOUNDER STROBE Model : AVD-C407

ELECTRONIC SOUNDER STROBE Model : AVD-C407 ELECTRONIC SOUNDER STROBE Model : AVD-C407 MULTRON range of combination Electronic Sounders with Strobe Lights are designed to complement our Fire Alarm products both technically and aesthetically as an

More information

SERIES 65 ENGINEERING PRODUCT GUIDE

SERIES 65 ENGINEERING PRODUCT GUIDE SERIES 65 ENGINEERING PRODUCT GUIDE Wide voltage conventional detectors Series 65 incorporates well-proven sensing technologies, including an IC based on that used in XP95 analogue addressable detectors.

More information

The supplier and installer of the system should be approved by the local civil defence authority.

The supplier and installer of the system should be approved by the local civil defence authority. ANALOGUE ADDRESSABLE FIRE ALARM SYSTEM 1. Scope of Work The contractor shall supply, install, test and commission a modern Analogue Addressable Fire Detection and Alarm System of an approved manufacturer

More information

FIREBETA EXTINGUISHING CONTROL PANEL (ECP)

FIREBETA EXTINGUISHING CONTROL PANEL (ECP) F I R E D E T E C T I O N A N D C O N T R O L FIREBETA EXTINGUISHING CONTROL PANEL (ECP) Three versions: 2 areas of detection and 1 area extinguishing 4 areas of detection and 1 area extinguishing 4 areas

More information

FSTP2-2-wire 2 Zone Conventional Fire Control Panel Operation and Maintenance Manual. Man-1078FS2 Issue 01 April 2012

FSTP2-2-wire 2 Zone Conventional Fire Control Panel Operation and Maintenance Manual. Man-1078FS2 Issue 01 April 2012 FSTP2-2-wire 2 Zone Conventional Fire Control Panel Operation and Maintenance Manual Man-1078FS2 Issue 01 April 2012 Index Page 0B1. Introduction... 3 1B2. Safety and mounting... 3 2B3. Technical specification...

More information

LC1 & 2. Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV

LC1 & 2. Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV LC1 & 2 Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV ZIRCONLC1 One Zone Conventional Fire Panel ZIRCONLC2 Two Zone Conventional Fire Panel Compliant with EN54-2:1998 & EN54-4:1998

More information

Protec. Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System. Fire Detection - Addressable

Protec. Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System. Fire Detection - Addressable Protec Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System ADDRESSING SAFETY SYSTEMS WITH INTELLIGENCE Protec Protec Algo-TecTM 6100 INTERACTIVE DIGITAL ADDRESSABLE FIRE CONTROL

More information

ALK-V PHOTOELECTRIC SMOKE SENSOR

ALK-V PHOTOELECTRIC SMOKE SENSOR ALK-V PHOTOELECTRIC SMOKE SENSOR APPLICATION The HOCHIKI America ALK-V Photoelectric Smoke Sensor is particularly suited to detecting optically dense smoke typical of fires involving materials such as

More information

FSTP4-2-wire 4 Zone Conventional Fire Control Panel Operation and Maintenance Manual. Man-1078FS4 Issue 01 April 2012

FSTP4-2-wire 4 Zone Conventional Fire Control Panel Operation and Maintenance Manual. Man-1078FS4 Issue 01 April 2012 FSTP4-2-wire 4 Zone Conventional Fire Control Panel Operation and Maintenance Manual Man-1078FS4 Issue 01 April 2012 Index Page 1. Introduction... 3 2. Safety and mounting... 3 3. Technical specification...

More information

Solution F2. Fire Alarm Control Panels one step ahead.

Solution F2. Fire Alarm Control Panels one step ahead. Solution F2 Fire Alarm Control Panels one step ahead. Sicherheitstechnik Sicherheitstechnik GmbH GmbH The Fire Alarm Control Panel Solution F2 Solution F2 in B2 enclosure (B01090-00) The Concept The Solution

More information

MINERVA MZX125. Digital Addressable Fire Detection System

MINERVA MZX125. Digital Addressable Fire Detection System A C C E S S C O N T R O L C C T V E A S R F I D F I R E P R O T E C T I O N I N T R U D E R A L A R M S DATA SHEET MINERVA MZX125 Digital Addressable Fire Detection System Features: Long term service and

More information

four Vigilon Compact Analogue Addressable Fire Detection & Alarm System 4/1

four Vigilon Compact Analogue Addressable Fire Detection & Alarm System 4/1 four Vigilon Compact Analogue Addressable Fire Detection & Alarm System 4/1 ANALOGUE FIRE DETECTION VIGILON COMPACT FEATURES & BENEFITS four Keep it Simple All Vigilon devices connect onto the same 2

More information

DICTATOR Hold-Open Systems for Hazardous Areas

DICTATOR Hold-Open Systems for Hazardous Areas DICTATOR for Hazardous Areas Products to be used in hazardous areas obviously have to meet special demands. The European ATEX directives (first the EN 94/9/EG and then the directive 2014/34/ EU) brought

More information

End To End Optical Beam Smoke Detector. Additional Information

End To End Optical Beam Smoke Detector. Additional Information End To End Optical Beam Smoke Detector Additional Information EN 1. Multiple Zone Wiring When using more than one System Controller on a single zone of a conventional Fire Control Panel (FCP), it is important

More information

Installation and user manual for the FX range of fire panels. 1, 2, 4 and 8 zone panels

Installation and user manual for the FX range of fire panels. 1, 2, 4 and 8 zone panels Installation and user manual for the FX range of fire panels 1, 2, 4 and 8 zone panels Contents Panel installation 3 Panel connections 3 Wiring connection drawings 4 Panel facilities 6 Installation check

More information

Vega Devices.

Vega Devices. Vega Devices This document lists the Argus Vega devices that are compatible with the Panels. It also highlights any specific requirements and technical information. Range of Fire Alarm Control The operation

More information

Installation and Operating Instructions

Installation and Operating Instructions Twinflex and Multipoint Installation and Operating Instructions Rafiki Protection Limited 55 Springvale Industrial Estate Cwmbran South Wales NP44 5BD United Kingdom Tel. (+44) 01633 865558 Fax (+44) 01633

More information

Fire Signalling. Signalling Solutions

Fire Signalling. Signalling Solutions Fire Signalling Signalling Solutions Introduction Introduction Klaxon Signals manufactures the world s largest range of sound signalling equipment and solutions for the European and worldwide market place.

More information

DUAL MONITORED INPUT/OUTPUT UNIT BN-305

DUAL MONITORED INPUT/OUTPUT UNIT BN-305 DUAL MONITORED INPUT/OUTPUT UNIT BN-30 Interactive fire detection systems Product Datasheet Features Interactive For interfacing and controlling external units to Autronica s interactive fire detection

More information

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel INSTALLATION, OPERATION AND MAINTENANCE MANUAL Version: CN-PM-1000.VER1.1-12/2012 EN54 INFORMATION In accordance with EN 54-2 clause 13.7, the maximum

More information

Intelligent Security & Fire Ltd

Intelligent Security & Fire Ltd full installation, commissioning and operating manuals can be downloaded from www.haes-systems.co.uk combined addressable / conventional fire alarm control panel User Guide Approved Document No. MFBU-04

More information

Conventional Fire Alarm System 2014 V1.2

Conventional Fire Alarm System 2014 V1.2 Conventional Fire Alarm System 2014 V1.2 Product Overview Control Panel 2 Conventional Fire Panel GST102A 2 zone Fire panel GST104A 4 zone Fire panel GST108A 8 zone Fire panel GST116A 16 zone Fire Panel

More information

Protec. Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System. Fire Detection - Addressable

Protec. Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System. Fire Detection - Addressable Protec Fire Detection - Addressable Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System ADDRESSING SAFETY SYSTEMS WITH INTELLIGENCE Fire Detection - Addressable Protec Protec Algo-TecTM

More information

Protec. Protec Algo-Tec TM 6500 Interactive Digital Addressable Fire Control System with Algo-Tec 6600 Bridging Network. Fire Detection - Addressable

Protec. Protec Algo-Tec TM 6500 Interactive Digital Addressable Fire Control System with Algo-Tec 6600 Bridging Network. Fire Detection - Addressable Protec Protec Fire Detection Pty Ltd Protec Algo-Tec TM 6500 Interactive Digital Addressable Fire Control System with Algo-Tec 6600 Bridging Network ADDRESSING SAFETY SYSTEMS WITH INTELLIGENCE CAUTION

More information

2018 Johnson Controls. Tyco Fire & Security GmbH, Victor von Bruns-Strasse 21, 8212 Neuhausen am Rheinfall, Switzerland DUO-CEL

2018 Johnson Controls. Tyco Fire & Security GmbH, Victor von Bruns-Strasse 21, 8212 Neuhausen am Rheinfall, Switzerland DUO-CEL OM_FC_DUO-CEL_APP 2018 Johnson Controls. Tyco Fire & Security GmbH, Victor von Bruns-Strasse 21, 8212 Neuhausen am Rheinfall, Switzerland DUO-CEL FIRE DETECTION/ALARM PANEL Application Guide PAGE 1 of

More information

USER MANUAL COMBINED FIRE & EXTINGUISHING CONTROL PANEL COMPLIES WITH BS EN PART 1 & EN54 PARTS 2 & 4

USER MANUAL COMBINED FIRE & EXTINGUISHING CONTROL PANEL COMPLIES WITH BS EN PART 1 & EN54 PARTS 2 & 4 PREMIER EX8 EXTINGUISHING PANEL USER MANUAL COMBINED FIRE & EXTINGUISHING CONTROL PANEL COMPLIES WITH BS EN 12094 PART 1 & EN54 PARTS 2 & 4 USER MANUAL Approved Document No: GLT.MAN-132 INDEX Extinguishing

More information

IFD-E Flame Detector User Manual

IFD-E Flame Detector User Manual IFD-E Flame Detector User Manual 2 Hochiki Europe (UK) Ltd General Description The flame detector is designed for use where open flaming fires may be expected. It responds to the light emitted from flames

More information

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres 1) Introduction The BExBG05D-SIL is a flameproof beacon which is certified

More information

EUROFIRE Fire Control Panel

EUROFIRE Fire Control Panel EUROFIRE Fire Control Panel User and Engineers Manual Revision 4 5 th January 2000 EMERGI-LITE SAFETY SYSTEMS LTD Bruntcliffe Lane, Morley, Leeds, West Yorkshire, LS27 9LL Tel: 0113 281 0600 Fax: 0113

More information

1200-HCM DIN RAIL MOUNTING FIRE SYSTEM MODULE Fire Detection & Extinguishant Control A R T PATOL LIMITED SUPPLY FAULT SOUNDER

1200-HCM DIN RAIL MOUNTING FIRE SYSTEM MODULE Fire Detection & Extinguishant Control A R T PATOL LIMITED SUPPLY FAULT SOUNDER Application The unit is primarily intended for use where there is a requirement to integrate a limited fire protection function into a larger control equipment scheme, or in specialist applications where

More information

D-Tect 2 GJD300 Quad PIR Movement Detector

D-Tect 2 GJD300 Quad PIR Movement Detector D-Tect GJD0 Quad PIR Movement Detector Package Contents 3. Package Contains: x D-Tect x Drilling template for fixing holes x Allen Key 3 x 3.75mm wall plugs 3 x 3.75mm screws x Spare Sliding Curtains x

More information

FIRE CONTROL PANEL. Revision 1.1 January 1997 USER MANUAL. Emergi-Lite Safety Systems Ltd Bruntcliffe Lane Morley Leeds LS27 9LL

FIRE CONTROL PANEL. Revision 1.1 January 1997 USER MANUAL. Emergi-Lite Safety Systems Ltd Bruntcliffe Lane Morley Leeds LS27 9LL FIRE CONTROL PANEL Revision 1.1 January 1997 USER MANUAL Emergi-Lite Safety Systems Ltd Bruntcliffe Lane Morley Leeds LS27 9LL Tel: 0113 281 0600 Fax: 0113 281 0601 C O N T E N T S PAGE INTRODUCTION...

More information

FIRE DETECTOR TYPE ED816 ZONE 5 ZONE 4 ZONE 6 ZONE 7 FIRE FIRE FIRE FIRE FAULT FAULT FAULT FAULT DISABLED DISABLED DISABLED DISABLED OFF OFF OFF OFF

FIRE DETECTOR TYPE ED816 ZONE 5 ZONE 4 ZONE 6 ZONE 7 FIRE FIRE FIRE FIRE FAULT FAULT FAULT FAULT DISABLED DISABLED DISABLED DISABLED OFF OFF OFF OFF DETECTOR TYPE ED816 ZE 1 ZE 2 ZE 3 ZE 4 ZE 5 ZE 6 ZE 7 S ZE 8 CIRCUIT 1 ZE 9 ZE 10 ZE 11 ZE 12 ZE 13 ZE 14 ZE 15 ZE 16 CIRCUIT 1 POWER POWER SUPPLY GENERAL MENT DC GENERAL SYSTEM ALARM DELAYED ALARM RESOUND

More information

SISTEMAS DE SEGURIDAD MIRA, S.L. COMPANY & PRODUCT GUIDE

SISTEMAS DE SEGURIDAD MIRA, S.L. COMPANY & PRODUCT GUIDE SISTEMAS DE SEGURIDAD MIRA, S.L. COMPANY & PRODUCT GUIDE Sistemas de Seguridad Mira, S.L. focuses on the design, development and manufacture of advanced components for fire detection systems. To secure

More information

Installation and Operation Manual

Installation and Operation Manual [Please read this installation & operation manual before install and use this Installation and Operation Manual Address: 8-701,Dongfangming Industry Zone, Dabao Road., Baoan, Shenzhen, China-518101 Page

More information

INFINITY 8 INSTALLATION MANUAL FIRE ALARM CONTROL PANEL INSTALLATION MANUAL

INFINITY 8 INSTALLATION MANUAL FIRE ALARM CONTROL PANEL INSTALLATION MANUAL FIRE ALARM CONTROL PANEL INSTALLATION MANUAL Approved Document No. GLT-201-7-1 CONTENTS 1. INTRODUCTION... 1.1 HANDLING THE PCBS... 1.2 USING THIS MANUAL... 1.3 ABOUT THE INFINITY FIRE ALARM CONTROL PANEL

More information

A GUIDE TO FIRE DETECTION AND ALARM SYSTEMS

A GUIDE TO FIRE DETECTION AND ALARM SYSTEMS A GUIDE TO FIRE DETECTION AND ALARM SYSTEMS A Fire detection and alarm ( FD+a ) system is what most workplaces and public accessed buildings have in place. The FD+a system has two primary functions and

More information

Door Release Power Supply

Door Release Power Supply www.protectingpeople.co.uk Door Release Power Supply Engineer / Installation Manual Document: VI55.1 Protecting People Printed : 04/03/2004-1 - Ventcroft Ltd Door Release Power Supply Engineer / Installation

More information

WD-CS. Water leak detection cable. Technical Overview. Features. Page 1. Data Sheet Ref: Issue: 5.1.

WD-CS. Water leak detection cable. Technical Overview. Features. Page 1. Data Sheet Ref: Issue: 5.1. Data Sheet Ref: 90501085 WD-CS Water leak detection cable Technical Overview The WD-CS range of cable sensors are typically used to detect water leaks usually under floors, and are used in conjunction

More information

IFD-E Flame Detector User Manual

IFD-E Flame Detector User Manual IFD-E Flame Detector User Manual 2 Hochiki Europe (UK) Ltd General Description The flame detector is designed for use where open flaming fires may be expected. It responds to the light emitted from flames

More information

Intelligent Security & Fire Ltd

Intelligent Security & Fire Ltd OPERATIONAL NOTES FOR CONCEPT FIRE PANEL. NOTE ON NEW FIRE PANELS, POSITION 1 ON THE SIX WAY INTERNAL OPTION SWITCH IS TURNED ON, DISABLING THE ZONAL SOUNDERS. TO ENABLE ZONAL SOUNDERS TURN OFF. Operation

More information

TX7130. Conventional Reflective Beam Detector Installation and Operation Manual. TANDA UK Technology Copyright 2015, All right reserved.

TX7130. Conventional Reflective Beam Detector Installation and Operation Manual. TANDA UK Technology Copyright 2015, All right reserved. TX7130 Conventional Reflective Beam Detector Installation and Operation Manual Technology Copyright 2015, All right reserved. Product Safety To prevent severe injury and loss of life or property, read

More information

Application, Installation, Operation & Maintenance Manual

Application, Installation, Operation & Maintenance Manual APPROVED BY:JBJ PRESCIENT III FIRE ALARM & GAS EXTINGUISHING CONTROL PANEL Application, Installation, Operation & Maintenance Manual PAGE 1 of 43 CONTENTS 1. INTRODUCTION... 3 2. GENERAL DESCRIPTION...

More information