AN-3100D Annunciator
|
|
- Amber Bradford
- 5 years ago
- Views:
Transcription
1 AN-3100D Annunciator FOR POWER GENERATION, TRANSMISSION & DISTRIBUTION, PETROLEUM, PETROCHEMICAL, AND OTHER PROCESS INDUSTRIES INNOVATIVE ANNUNCIATOR Continuing with the widely successful AN-3100 series of annunciators, AMETEK s new AN-3100D brings alarm monitoring to new levels. Time stamped alarms and more communication options are now available. Installation and setup have been simplified making this an ideal fit for new projects or system replacements. The unique software configuration provides more features and functions a mouse click away. Time Stamped Alarms (SER) All of your alarms can include a time stamp, synchronized by IRIG-B or our internal clock. This can be presented through Modbus, DNP, OPC or to a local printer or terminal for viewing. Communications Transmit or receive alarms using our RS-232/485 serial or Ethernet port. The AN-3100D supports Modbus and DNP protocols. Communicate via OPC using our OPC Server Software. Software Configuration While all systems are pre-configured to your specifications, the software configuration tool unleashes the true power of the AN-3100D. You can select any operational sequence, sort alarms by group, configure your relay outputs and more. There is never any reason to pull out the front accessible input cards as changes can be made via software. Compact Size The annunciator and all electronics including the communication options are self contained within a compact frame less than seven inches deep. In most cases, the power supply is included inside the system simplifying installation and wiring. Reliability Every AN-3100D annunciator is equipped with low power, long life LEDs. The brightness exceeds standard incandescent bulbs and they last years longer. If a LED needs replacement, our automatic detector provides notice so critical alarms are not missed. A built-in ground fault detector is available for indicating ground faults in your field wiring. Flexible Design The window legends are printed on standard transparency film, making it easy to change legends at any time. The annunciator capacity can be increased with built-in expansion. All features and options are field selectable and upgradeable. FEATURES AND BENEFITS Timed Stamped Alarms (SER) LED Illumination (Standard) Serial and Ethernet Communications: Modbus, DNP, OPC Protocols Software Configurable Laser Printed Legends Internal Self Diagnostics Compact Size Experience the Power
2 SPECIFICATIONS INPUT Field Contacts Normally Open (N.O.) or Normally Closed (N.C.) input selection through software or hardware Wetted (voltage supplied) or dry (voltage free) contacts Field Contact Voltage 12, 24, 48, 125 VDC, 120 VAC jumper selectable (.0018mA per input) Input Isolation Each input is optically isolated Input Response 50 milliseconds (standard) 1 millisecond fast response (opt) 50 milliseconds to 250 seconds software adjustable DISPLAY LED White LED, minimum 2 per window Window Sizes (h x w) Quad: 1.5 x 1.5 inch (38 x 38 mm) Third: 1.0 x 3.0 inch (25 x 76 mm) Half: 1.5 x 3.0 inch (38 x 76 mm) Full: 3.0 x 3.0 inch (76 x 76 mm) Window Color White, red, yellow, amber, green, blue Legends Laser printed on transparency film or engraved windows ALARM SEQUENCE Sequence Selections A, A4, M, R, R12, F1A, F3A, F2M1, FFAM2, F3C and R12C Software configurable - Dual color sequences - Customized flash rates - Up to 4 first out groups CONTROLS Integral test, acknowledge, silence and reset with LED status lights External push button inputs Configurable switch inputs (inhibit LEDs, horns, relays) OUTPUTS Auxiliary Relay Option Individual or dual relay per point Follows field contact or alarm sequence Software configurable Energized/de-energized operation Form A or form B (N.O. or N.C.) Form C (SPDT) Common Relays 2 relays included for: critical and noncritical horn; ringback audible 2 relays available for: critical and noncritical reflash, common alarm; watchdog, power fail, ground fault Software configurable Energized or de-energized operation Form A or form B (N.O. or N.C.) Relay Ratings amps amps amps Audible Internal 30cm audible device external horns available COMMUNICATION Serial Modbus Master or slave Transmit or receive alarms RS-232/485 or Ethernet Pushbutton controls DNP 3.0 Slave mode Transmit alarms RS-232/485 or Ethernet Pushbutton controls OPC Server Software Ver. 2.0 OPC DA Serial ASCII RS-232/485 or Ethernet For local terminal/printer TIME STAMPED ALARMS 1 or 4 msec time stamp resolution IRIG-B time sync input or internal clock Point #, alarm status, time and date Modbus, DNP, ASCII outputs 500 event storage CONNECTIONS Input/Output Terminals Fixed barrier terminal block, 12 GA (2.5mm) maximum, ring, spade or bare wire termination. Communication Ports Serial: 9 pin female D connector Ethernet: RJ45 connector IRIG-B: BNC connector POWER REQUIREMENTS Internal or External Power Supplies 230 VAC ( VAC 50 Hz) 120 VAC ( VAC 60 Hz) 125 VDC ( VDC) 48 VDC (38-58 VDC) 24 VDC (19-29 VDC) Max. 1.7 power input MECHANICAL Mounting Semi-flush panel mounting 19 inch rack mounting Wall (surface) mounting NEMA enclosures Weight 1.2 lbs per cell (0.34 kg per cell) ENVIRONMENT Operating Temperature Range: -4 to 122 O F (-20 to 50 O C) Humidity: 20-95% RH Surge Withstand: ANSI C (oscillatory) Fast Transient: IEC Surge Immunity: IEC EMI/RFI/ESD: IEC , 4-6, 6-3, 4-8, 4-2 Isolation: 1950 VDC or 1400 VAC input to output, logic, case CERTIFICATIONS CE, FM Class 1, Div 2, FMC UL, ULC, CSA Pending Semi-flush Mounting Details inches (mm) Cells Overall Panel Cut-Out H or W H or W H or W (127) 4.06 (103) (215) 7.53 (191) (303) (279) (391) (368) (479) (456) (568) (544) (656) (632) (744) (720) (832) (808) (920) (896) (1008) (984) (1096) (1072) (1184) (1160) Depth behind panel: 6.75", 8" with rear cover Example: 2 H x 3 W has a cut-out height of 7.53 (191) and a cut-out width of 11.0 (279) For customer support call: POWER INSTRUMENTS 255 North Union Street Rochester, NY Tel: Fax: HEADQUARTERS AMETEK Power Instruments 50 Fordham Road Wilmington, MA Tel: Fax: EUROPEAN HEADQUARTERS Unit 20, Ridgeway Donibristle Industrial Estate Dalgety Bay, Dunfermline, KY119JN Scotland U.K. Tel: Fax: ASIA PACIFIC HEADQUARTERS 10 Ang Mo Kio Street 65 #05-12 Techpoint Singapore Tel: Fax: ISO 9001 Certified 2005, by AMETEK, Inc. All rights reserved. 3M804A (210075)
3 D I S T R I B U T E D A L A R M M A N A G E M E N T DMS-3000 Modular Alarm System FOR SAFETY CRITICAL ALARM AND EVENT LOGGING ON PROCESS AND POWER PLANTS MODULAR ALARM SYSTEM The AMETEK DMS-3000 Alarm Management System is a flexible remote alarm monitoring system.it can operate as a remote annunciator, with all inputs connected to our compact card rack and the lamp displays installed wherever convenient. Or it can combine the annunciation with sequential events recording and provide a 1 msec time stamp on all alarms. All of this alarm inform-ation can be transmitted through our serial ports using Modbus and OPC. Each input card rack can accept analog or digital contact inputs. Any of these inputs or groups of inputs can be used to drive an annunciator lamp, repeat relay, horn, or common alarm output. The DMS-3000 works well in distributed applications as each input card rack can be located close to the field inputs. All of these card racks are connected to a Data Concentrator via long length RS-422 cables up to 1,000 meters. The Data Concentrator provides a common time synchronization for all inputs and collects all the alarm information at one common point, for transmission to other systems using serial modbus. Managing these alarms is easily accomplished with our RiSCue Alarm Management Software. RiSCue organizes all of the alarms in a descriptive text format or can even simulate the annunciator windows used. RiSCue also provides automatic notification through the phone, pager, public address system, , fax, and more. Critical alarms are easily sorted by priority or time of occurrence making it easy to determine the root cause of any disturbance. FEATURES AND BENEFITS Remote Annunciator - Ideal when alarm inputs remote are separate from the control room display Sequence of Events Recorder - Time stamping of alarms with 1 msec resolution Multifunction capability from single alarm input - Saves on installation, wiring, hardware cost High Density System - Up to 128 digital or 32 analog inputs per 19 inch rack Multiplex inputs to outputs - Multiple inputs can drive a single display window Distributed Architecture - Input card racks can be located up to 1,000 meters away Modbus and OPC Outputs - Communicate alarm information to other systems RiSCue Alarm Management Software - Windows-based, network ready Experience the Power
4 D I S T R I B U T E D A L A R M M A N A G E M E N T SPECIFICATIONS INPUTS Digital Contacts N.O. or N.C., field selectable via internal DIP switches Input Current Approximately 2mA per input Field Contact Voltage 24 VDC nominal 48 VDC nominal 125 VDC nominal Analog Inputs 4-20mA and 1-5 VDC Input Loop Resistance N.O. 200K ohm minimum N.C. 1K ohm maximum Time Stamp Resolution 1mS on occurrence and 1mS on clearance between digital events when accessed with a data concentrator or Modbus Input Response Digital input: 16mS Analog input: 40mS System Capacity 128 digital inputs per remote unit or 32 analogs or combination of both OUTPUTS Lamp Drive 24 VDC, 5 watts Power Relays S.P.D.T contact rating 24 VDC 2.0 amp resistive. 240 VAC 1.0 amp resistive Reed Relays S.P.S.T contact rating 100 VDC 0.25 amp maximum resistive Capacity 224 outputs per remote unit Diagnostic Watchdog output COMMUNICATIONS CPU for Remote Annunciator Systems used for system configuration, optional Modbus CPU for Combined Annunciator and Sequential Events Recording Systems used for communication to Data Concentrator Serial Data RS232/RS422 Baud Rates Up to (9600 standard) Communications Full duplex, 8 bit, 1 stop bit, no parity Distance between Input Card Rack and Data Concentrator RS ft./15 M RS-422 4,000 ft./1,200 M CONFIGURABLE FEATURES Editor Onboard accessed through RS232 port Input Time Delays 0.04 seconds to 40 minutes in approximately 40mS increments Flash Rates Fast 80/140 per minute Slow 15/25 per minute Sequences All sequences to IAS-S Pushbutton Controls 16 Groups can be assigned and configured for controls functions. - Alarm Accept - Lamp Test - First Up Accept - Reset - Function Test - Horn Silence Audible 16 alarm audibles 1 ringback audible General Groups 1 global group 15 individual groups Inhibit Individual and group available DATA CONCENTRATOR Time Synchronization IRIG-B, PPS Serial Inputs RS-232/422 serial link from input card racks 2048 inputs per data concentrator Up to 16 input card racks Outputs RS-232/422/485 Serial Output Single or dual outputs Protocols TADS (Timed Alarm Data System) Serial Modbus (through converter) OPERATING VOLTAGES Prime Power 24,48 and 125 Volts +12% 120/240 Volts AC 50/60 Hz MECHANICAL Input Card Rack Single Chassis, 10 card slots 5.5" H x 7.25" D x 19.0" W Dual Chassis, 23 card slots 11.5" H x 7.25" D x 19.0" W Data Concentrator Single Chassis, 10 card slots 5.5" H x 7.25" D x 19.0" W Mounting Front or rear optional Terminals Combined edge connector with terminal block - up to 1.5 sq mm VOLTAGE WITHSTAND Isolation IEC255-5 Surge Withstand IEC Impulse Withstand IEC Burst Immunity IEC RFI IEC ESD IEC Emissions EN ENVIRONMENTAL Operating Temperature 32 O to 140 O F (0 O to 60 O C) Storage Temperature -13 O to 185 O F (-25 O to 85 O C) Humidity 0 to 90% non-condensing For customer support call: POWER INSTRUMENTS 255 North Union Street Rochester, NY Tel: Fax: power.industrial@ametek.com HEADQUARTERS AMETEK Power Instruments 50 Fordham Road Wilmington, MA Tel: Fax: power.industrial@ametek.com EUROPEAN HEADQUARTERS Unit 20, Ridgeway Donibristle Industrial Estate Dalgety Bay, Dunfermline, KY119JN Scotland U.K. Tel: Fax: sales@ametekuk.com ASIA PACIFIC HEADQUARTERS 10 Ang Mo Kio Street 65 #05-12 Techpoint Singapore Tel: Fax: ISO 9001 Certified 2003, by AMETEK, Inc. All rights reserved. XM1002 (XXXXXX)
5 AN-6150 Modular Display Unit FOR POWER GENERATION, TRANSMISSION AND DISTRIBUTION, PETROLEUM, PETROCHEMICAL, AND OTHER PROCESS INDUSTRIES COMPACT LAMP-BOX The Model AN-6150 is a compact, modular lamp display used for connection to remote logic annunciators, PLC s or other equipment. It can be configured in any matrix up to 5 cells high and 4 cells wide. It has four standard window sizes allowing you to compact as many alarms as needed in your allowable panel space. Six window colors are available which can be back lighted by incandescent lamps. Alternatively, LED lamps are available to meet long life requirements. Legends are laser printed on clear transparencies to allow changes to be done by the customer. Pushbutton membrane switches can also be added for Silence, Test, Acknowledge, and Reset functions. These units come standard with flush panel mounting, including hardware and rear terminal block field connections. Please refer to ordering information for additional options. WINDOW COLORS Red, amber, yellow, green, blue, white illuminated by incandescent lamps. Red, amber, green illuminated by LED clusters. LEGEND Laser printed on clear film or engraved filters. Secret window until lit and secret legends optional. ILLUMINATION #656 wedge type bulb, long life, 28 volt, 0.06 Amp filament lamp or equivalent. Dual lamps in all window sizes. Dual lamps are optional in small window size. Optional illumination by LED cluster each 24 volt, amp with limited colors. WINDOW SIZES Four standard sizes. Small: 0.98 in. x 1.14 in. (25 mm x 29 mm) Medium: 0.98 in. x 2.40 in. (25 mm x 61 mm) Large: 2.13 in. x 2.40 in. (54 mm x 61 mm) Ex Large: 2.13 in. x 4.96 in. (54 mm x 126 mm) FEATURES AND BENEFITS Low Cost Visual Display Configurable in 4 Standard Window Sizes Compact High-density Design Laser Printed Legends Easy Installation and Maintenance Sizing Details: in. (mm) Number of Cells Wide Bezel Width (144) (274) (404) (534) - Cut-out Width (138) (268) (398) (528) - Number of Cells High Bezel Height (72) (130) (188) (246) (305) Cut-out Height (66) (124) (182) (241) (299) Allow 2.25 depth behind panel Experience the Power
6 SPECIFICATIONS CONSTRUCTION Modular interlocking matrix configuration, multiples of standard DIN size 72 mm x 144 mm (2.83 in. x 5.67 in.) cells up to 5 cells high by 4 cells wide MOUNTING Flush panel mount or standard 19 inch rack panel mount for 3 cell wide display only CONNECTIONS Ribbon cable or terminal block accepting maximum wire size 16 AWG AMBIENT WORKING TEMPERATURE 14 O to 122 O F (-10 O to 50 O C) RECOMMENDED WORKING VOLTAGE 24 volts +10% for increased lamp life with 28 volt lamp POWER REQUIREMENTS Each cell has a total of 8 plug-in filament lamps or LED clusters. Power required per cell: 28 volt lamp Working at 24 volts: 0.5 amp, 12 watts, 24 volt LED cluster working at 24 volts: 0.2 amp, 4.8 watts CONTROL MODULE SILENCE, TEST, ACKNOWLEDGE, and RESET membrane pushbuttons within a large size window (54 mm x 61 mm 1/2 cell size) (2.13 in. x 2.40 in.) including internal audible device and visual power on indicator WEIGHT 0.48 lbs. (0.22 kg) per cell AN6150 Ordering Information TYPICAL MODEL NUMBER (coded by color) AN6150-3H-5W INTB S VW 48A R STH Code Description AN6150-X-Y X = Display Height Y = Display Width Common Service Module INTB Integral CSM wit Pushbuttons (touch pad mounted in the lower right cells) RPB Remote Panel Mounted CSM (with pushbuttons) NPB No Pushbutton Window Size S Small Window, 8 per Cell (0.98" x 1.14") M Medium Window, 4 per Cell (0.98" x 2.40") L Large Window, 2 per Cell (2.13" x 2.40") EL Extra Large Window, per Cell (2.13" x 4.96") IMW Intermix Window Size, Matrix Must Be Included Window Type VW Legends Are Laser Printed on Transparency Film (standard) SW Laser Printed Legends Are Hidden Until Lit (not available in LEDs) VL Legends Are Engraved on Windows SL Legends Are Hidden Until Lit, Engraved on Windows Lamp Type 24C Incandescent Lamps, 24 VDC 24W White LED Cluster Lamps, 24 VDC 24R Red LED Cluster Lamps, 24 VDC 24A Amber LED Cluster Lamps, 24 VDC 24Y Yellow LED Cluster Lamps, 24 VDC 24B Blue LED Cluster Lamps, 24 VDC 24G Green LED Cluster Lamps, 24 VDC 48W White LED Cluster Lamps, 48 VDC 48R Red LED Cluster Lamps, 48 VDC 48A Amber LED Cluster Lamps, 48 VDC 48Y Yellow LED Cluster Lamps, 48 VDC 48B Blue LED Cluster Lamps, 48 VDC 48G Green LED Cluster Lamps, 48 VDC Window Color R Red Window Y Yellow Window G Green Window A Amber Window W White Window B Blue Window (not available when using LEDs) IMC Intermix Window Color, Matrix Must Be Included Standard Options STD/1 19" Rack Mounting for 1 High x 3 Wide Displays STD/2 19" Rack Mounting for 2 High x 3 Wide Displays STD/3 19" Rack Mounting for 3 High x 3 Wide Displays STD/4 19" Rack Mounting for 4 High x 3 Wide Displays STD/5 19" Rack Mounting for 5 High x 3 Wide Displays STD/6 19" Rack Mounting for 6 High x 3 Wide Displays STD/X 19" Rack Mounting for Units Higher than 6 High STY Integral Plug Connector, 32 Points per Plug STH Integral Control Pushbuttons NR No Options Required For customer support call: POWER INSTRUMENTS 255 North Union Street Rochester, NY Tel: Fax: HEADQUARTERS AMETEK Power Instruments 50 Fordham Road Wilmington, MA Tel: Fax: EUROPEAN HEADQUARTERS Unit 20, Ridgeway Donibristle Industrial Estate Dalgety Bay, Dunfermline, KY119JN Scotland U.K. Tel: Fax: ASIA PACIFIC HEADQUARTERS 10 Ang Mo Kio Street 65 #05-12 Techpoint Singapore Tel: Fax: ISO 9001 Certified 2005, by AMETEK, Inc. All rights reserved. 5M703A (210064)
7 AN-6100C Annunciator FOR POWER GENERATION, TRANSMISSION AND DISTRIBUTION, PETROLEUM, PETROCHEMICAL, AND OTHER PROCESS INDUSTRIES ALARM MONITORING SYSTEM AMETEK s AN-6100C Annunciator has all the features you need for an alarm monitoring system. Simple to install, configure and operate and flexible to change, expand and grow to meet future requirements. The AN-6100C has all these qualities along with reliable operation for your most critical needs. The AN-6100C is maintenance free; once installed, you will never have to worry about it. COMPACT DESIGN With a depth less than 4-1/2", it can be easily installed into control panels, system cabinets and consoles. It is an ideal fit for replacing older systems or for new installations. The high density design provides up to 44 alarms in just 80 square inches of panel space FLEXIBLE CONFIGURATION Create any system size up to 10 rows by 20 columns of windows. Four windows sizes are available in several colors. The large windows can easily be converted into smaller ones, providing instant expansion for the future. HIGH RELIABILITY Each AN-6100C annunciator is equipped with low power, long life white LEDs. Each alarm point uses a pair of LEDs providing ample illumination in all light conditions. You never have to worry about changing a lamp or having it fail when you need it the most. MULTI-FUNCTION All features and options are provided in a single model, making it easy to order or to change in the future. Our innovative software configuration tool is used to change any system parameter, such as: ISA alarm sequence, alarm grouping, input delays, or relay operation. SERIAL COMMUNICATION Alarm information is easily transmitted or received with the bi-directional serial Modbus communications. The RS-232/485 serial communications can act as a slave or master providing control or monitoring of the alarm information. FIELD CHANGEABLE The window legends are printed on standard transparency film, making it easy to change legends at any time. Even options like serial Modbus can be added in the future through a factory supplied password. FEATURES AND BENEFITS Compact design Minimal depth behind panel Bi-directional serial communications LED illumination Multi-function Software configured Laser printed legends Removable terminal blocks Experience the Power
8 SPECIFICATIONS INPUT Field Contacts Normally Open (N.O.) or Normally Closed (N.C.) input selection through DIP Switch Wet (voltage supplied) or dry (voltage free) contacts Field Contact Voltage 5, 24, 48, 125 VDC, 120 VAC/DC 24 VDC open collector 24 VDC provided by annunciator power supply. Other voltage customer supplied. Input Isolation Each input is optically isolated Inputs share common return* *120 VAC/125 VDC input option provides isolation input to input Input Response 50 milliseconds (nominal) Adjustable to 2 seconds DISPLAY LED Dual white LED, 24 VDC Window Sizes Small: 0.98 x 1.14 in. (25 x 30 mm) Medium: 0.98 x 2.40 in. (25 x 60 mm) Large: 2.13 x 2.40 in. (55 x 60 mm) Extra Large: 2.13 x 4.96 in. (55 x 125 mm) Window Color White, red, yellow, amber, green, blue Legends Laser printed on transparency film OUTPUTS Auxiliary Relay Option Individual relay per point Follows field contact or alarm sequence Energized or de-energized Form A or Form B (N.O. or N.C.) Common Relays Four relays selectable for: - Critical and non-critical: horn, reflash, common alarm - Ringback audible, watchdog Energized or de-energized Form A or Form B (N.O. or N.C.) Relay Ratings amps amps amps Audible Internal 80db audible device SERIAL MODBUS OPTION RS-232 or RS-485 Modbus RTU or ASCII Master or slave mode Monitor mode (alarm information transmitted externally) Actuate mode (alarm information received externally) Pushbutton controls CONNECTIONS Input/Output Terminals Two-part removable screw type Maximum wire size: 12 AWG (2.5 mm) Communication Port 9 Pin Female D connector POWER REQUIREMENTS Operating Range: 24 VDC +15% Burden: 7.5 VA per 8 inputs External Power Supply Options: VAC 50/60 Hz VDC VDC MECHANICAL Display Module (cell) 2.83 H x 5.67 W (72 x 144 mm) 1, 2, 4, 8 windows per cell Weight 0.85 lb. per cell (0.4 kg per cell) ENVIRONMENT Operating Temperature Range: -4 to 122 O F (-20 TO 50 O C) Humidity: 20-95% RH Surge Withstand: ANSI C Isolation: 1950 VDC or 1400 VAC input to output/ case/common, output to case/common CERTIFICATIONS CE, UL, ULC ALARM SEQUENCE Sequence Selections ISA-A, A4, A456, M, R12, F1A, F2M, FFAM2, F3A, R12C, F3C Dual color sequences Customized flash rates Up to 4 first out groups CONTROLS Integral Test, Acknowledge, Silence and Reset External Pushbutton Inputs Annunciator Mounting Details in. (mm) Number of Cells Wide Bezel Width (148) (279) (410) (541) (671) Cut-out Width (140) (270) (401) (532) (663) Number of Cells High Bezel Height (76) (134) (193) (251) (310) Cut-out Height (68) (126) (184) (243) (301) Allow 4.5" depth behind panel For customer support call: POWER INSTRUMENTS 255 North Union Street Rochester, NY Tel: Fax: HEADQUARTERS AMETEK Power Instruments 50 Fordham Road Wilmington, MA Tel: Fax: EUROPEAN HEADQUARTERS Unit 20, Ridgeway Donibristle Industrial Estate Dalgety Bay, Dunfermline, KY119JN Scotland U.K. Tel: Fax: ASIA PACIFIC HEADQUARTERS 10 Ang Mo Kio Street 65 #05-12 Techpoint Singapore Tel: Fax: ISO 9001 Certified 2005, by AMETEK, Inc. All rights reserved. 5M405CW (210063)
Model A1700 Series Annunciator
Seekirk Model A1700 Series Annunciator Applications: For usage in all types of process industries, electric generation, transmission and distribution, gas and water utilities. Features: The Seekirk model
More informationDRAFT 20 October 2014
Technical data MTL process alarm equipment EPS rev 8 Programmable alarm annunciator Modular construction from 1 to 256 alarm channels Multi-redundant design so there is no single point of failure Choice
More informationAIS750 Series Alarm Annunciator User Manual (Ver. 2.3 / JUNE. 2014)
AIS750 Series Alarm Annunciator User Manual (Ver 23 / JUNE 2014) 3-350 John Street, Thornhill, tario L3T 5W6 Phone: 289 597 APEX (2739) Fax: 289 597 2200 Toll Free: 1 866 776 2943 Email: mail@annunciatorca
More informationModel A1600 Series Annunciator
Seekirk Model A1600 Series Annunciator Applications: For usage in all types of process industries, electric generation, transmission and distribution, gas and water utilities. Features: The Seekirk model
More informationX11CA COMPUTER ANNUNCIATORS
S E R I E S XCA COMPUTER ANNUIATORS E N G I N E E R I N G C O M P A N Y The Ronan Series XCA Computer Annunciators are the latest generation of Ronan s state-of-the-art annunciators offered in window models.
More informationSeries 725 Programmable Alarm Annunciator
Series 725 Programmable Alarm Annunciar Multi-redundant design for greater reliability Modular construction from 1 256 alarm channels Multi-redundant design so there is no single point of failure Choice
More informationAIS750 Series Alarm Annunciator
Unparallel, modular, multipoint design with Integrated controllers Two Operation Modes (Stand-alone & Serial) All sizes confi gurable up to 440 Alarm Points RS485 / RS232 Serial Communication Manual &
More informationSystem 9000TS Sequence of Events Recorder
System 000TS Sequence of Events Recorder ms Event Recorder and combined Annunciator Modular, rack mounting design expandable to over 000 inputs ms time stamping of events across the whole system Up to,000
More informationModel A2100 Series Annunciator
Seekirk Model A2100 Series Annunciator Applications: For usage within transformers, switchgear, breakers and/or within any processing equipment or control room applications either attended or unattended
More informationComplex alarming made simple
SEL-2523 Annunciator Panel Complex alarming made simple Superbright LEDs provide easily visible alarm indication in any lighting condition. Sequential Events Recorder (SER) data help identify the root
More informationReplaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge
Replaceable LED modules 11 Alarm Sequences as per ISA-18.1 standard Each channel/window fully field programmable RS232 or RS485 MODBUS-RTU communication Repeat relay for each window and multifunction relays
More informationRTK 9000TS system. MTL sequence of events recorder. Technical data MTL process alarm equipment
Technical data MTL process alarm equipment EPS RTK 9000TS Rev RTK 9000TS system MTL sequence of events recorder Modular, rack mounting design expandable to over 900 inputs ms time stamping of events irrespective
More informationSystem 9000TS Sequence of Events Recorder
System 9000TS Sequence of Events Recorder ms Event Recorder and combined Annunciator The RTK System 9000TS Sequence of Events Recorder leads the way in the latest technically advanced event and alarm management
More informationSystem 9000TS Event Recorder
Important notes The 9000TS System described herein operates on a logic voltage of VDC and as standard +VDC is used for the field contact supply voltage. External power supplies using higher voltage ac/dc
More informationSIL725 Safety Annunciator
SIL725 Safety Annunciar Configurable SIL2 Annunciar certified IEC61508 SIRA certified at safety integrity level SIL2 IEC61508 Modular construction from 1 128 alarm channels Multi-redundant design Choice
More information725B Configuration Software Manual
725B Configuration Software Manual REV DATED DESCRIPTION AUTHOR APPROVED 0 09-03-10 First Issue P.Cartmell Page 1 of 80 SECTION 1 - SOFTWARE INSTALLATION... 5 725B ConfigurationSoftware Installation...
More information21-light Remote Annunciator. Owner s Manual
21-light Remote Annunciator Owner s Manual Annunciator Description... Inside Font Cover Detailed Specifications... 1 Environmental Specifications... 1 Power Supply Requirements... 1 Communication With
More informationME 3011C / Alarm Indication / Quick Reference Guide
Tables of Contents Page Application 1 Features 1 Important Safety Information! 2 Note to this Guide 2 Further Information 2 Device Variants 2 General Functions 3 Annunciator Sequences - ISA 18.1 3 Plan
More informationInstruction manual MTL process alarm equipment. October 2016 CSM 725B rev 2 MTL RTK 725B. Configuration Software Manual
Instruction manual MTL process alarm equipment October 2016 CSM 725B rev 2 MTL RTK 725B Configuration Software Manual SECTION 1 - INTRODUCTION... 5 Basic Requirements... 5 SECTION 2 - SOFTWARE INSTALLATION...
More informationTechnical Manual. Level Alarm Unit CARLA & WIDS
CARLA & WIDS Technical Manual SAS au Capital de 2 158 244-444 871 933 R.C.S. Bourges - APE : 2651B Headquarter : 9, rue Isaac Newton - 18000 Bourges - France Technical Manual CARLA for Tankers Cargo Tanks
More informationESSEX ENGINEERING CORPORATION
WATER/WASTEWATER TREATMENT CONTROL SYSTEMS AND SUBSYSTEMS 2000 SERIES CONTROL SYSTEMS: 2000 series are for surface mounting inside a control cabinet Model 2024 Electronic Alternator Duplex (two pump) pump
More informationABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements
Specifications COMMANDER 150 Universal Process Indicator High visibility 6-digit LED display the clearest view of your process status 0.1% measurement accuracy precise indication of process measurement
More informationSoft Start Series MP700 Solid State, Reduced Voltage
Metron Fire Pump Controls and Accessories Soft Start Series MP700 Solid State, Reduced Voltage Metron Fire Pump Controllers conform to the latest requirements of National Fire Protection Association s
More informationSUB-STATION ANNUNCIATOR INSTRUCTION MANUAL
SUB-STATION ANNUNCIATOR INSTRUCTION MANUAL Page 1 of 76 The following methods are used in this manual to alert the user to important information:- WARNING! Warnings are provided for operator safety and
More informationTwo-Channel Gas Controller
Two-Channel Gas Controller Specifications subject to change without notice. USA 09 Page of DESCRIPTION Highly configurable, UL 0 performance-tested and -certified, and wall-mounted gas monitor; continuously
More informationAcross-the-Line SERIES MP300 Combined Manual and Automatic
Across-the-Line SERIES MP300 Combined Manual and Automatic Metron Fire Pump Controllers conform to the latest requirements of National Fire Protection Association s Standard for Centrifugal Fire Pumps
More information/8 DIN Level Indicator
Data Sheet SS/_6 High visibility 5-digit LED display clear and accurate indication Analog and relay outputs as standard high, low, latch and rate alarms, plus isolated retransmission Maths functions included
More informationSEL-2523 Advanced Annunciator Panel
SEL-2523 Advanced Annunciator Panel Complete Alarm Monitoring, Annunciation, and Communication Major Features and Benefits High Reliability, Low Price Ten-Year, Worldwide Warranty 40 to +85 C Operating
More informationANNUNCIATOR INSTRUMENTS Model PD141AFO Instruction Manual
ANNUNCIATOR INSTRUMENTS Model PD141AFO Instruction Manual From urgent alarms to routine messages, the PD141AFO VIGILANTE handles all types of operational messages with simplicity and economy. The VIGILANTE
More information4 & 8-POINT ANNUNCIATORS Instruction Manual
4 & 8-POINT ANNUNCIATORS Instruction Manual 8 Field Selectable Sequences All Common ISA Sequences 4 or 8-Point (Channel) Monitoring Free Replaceable Message Labels Type 4X, NEMA 4X, IP65 Front Universal
More informationNGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3
NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM Local configuration and monitoring with Raychem Touch 1500 touch screen display PRODUCT OVERVIEW The Raychem NGC-40 is a multipoint electronic
More informationSUPREMATouch. Modular Fire & Gas Detection System
SUPREMATouch Modular Fire & Gas Detection System Fire & Gas Detection Solutions MSA permanent gas detection systems are used throughout the world to protect plant and personnel from hazardous gases in
More informationUDC1000 and UDC1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS
UDC1000 and UDC1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS EN0I-6041 4/01 PRODUCT SPECIFICATION SHEET OVERVIEW The UDC1000 and UDC1500 are microprocessor-based 1/16 DIN and 1/8 DIN controllers
More informationData Sheet Fire Safety & Security Products. System Overview. Initiating Circuits SXL-EX FACP 7906
s Data Sheet Fire Safety & Security Products SXL-EX Fire Alarm Control Panel Conventional Zone Fire Alarm Control Panel ARCHITECT AND ENGINEER SPECIFICATIONS Four (4) zones expandable to eight (8) zones
More informationNGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3 PRODUCT OVERVIEW
NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM Local configuration and monitoring with Raychem Touch 1500 touch screen display PRODUCT OVERVIEW The nvent RAYCHEM NGC-40 is a multipoint
More informationSUPREMATouch. Modular Fire & Gas Detection System
SUPREMATouch Modular Fire & Gas Detection System Tel: +44 (0)8 9388 Email: info@ Fire & Gas Detection Solutions MSA permanent gas detection systems are used throughout the world to protect plant and personnel
More informationME 3011 compact. Electronic Alarm Indication Systems. Power Station Control Systems. Automation Equipment. Power Distribution Control Systems
Electronic Alarm Indication Systems ME 3011 compact Power Station Control Systems Power Distribution Control Systems Control Room Technology Automation Equipment 2 Table of Contents Contents Page System
More informationAO Annunciator Module
General Specifications GS48C43Z01-00E-N AO-543-01 Annunciator Module GENERAL Figure 1 This module has two independent annunciator circuits. The circuits handle fault signals and operator actions (acknowledge,
More informationStandard Devices. Electronic Alarm Indication Systems. ME 3011b
Standard Devices Electronic Alarm Indication Systems ME 3011b Before connecting and powering this device, please read carefully the manual, and refer to it whenever you have any doubts. This brochure is
More informationNov 08 PRODUCT SPECIFICATION SHEET
Honeywell UDC1200 and UDC1700 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS 51-52-03-35 Nov 08 PRODUCT SPECIFICATION SHEET OVERVIEW The UDC1200 & UDC1700 are microprocessor-based 1/16 DIN and 1/8 DIN
More informationPWGSC Ontario MULTIPLEX FIRE ALARM SYSTEM Sect Region Project Page 1 Number R
Region Project Page 1 PART 1 - GENERAL 1.1 REFERENCES.1 CAN/ULC-S524-2006, Standard for the Installation of Fire Alarm Systems..2 CAN/ULC-S525-2007, Audible Signal Device for Fire Alarm Systems..3 CAN/ULC-S526-2007,
More informationAddressable Fire Alarm Control Panel
PRODUCT SPECIFICATION XR2400F Addressable FACP Addressable Fire Alarm Control Panel Description The DMP XR2400F Addressable Fire Alarm Control Panel is an expandable Fire Alarm Control with built-in DACT
More informationUniversal fault annunciator for panel mounting
Universal fault annunciator for panel mounting Communication over Ethernet USM - Universal-fault annunciator for panel mounting Low depth housing for panel mounting Versions with 8, 16, 32 or 48 inputs
More informationX16PDM P R O G RAMMABLE
S E R I E S XPDM P R O G RAMMABLE D I G I T A L M O N I T O R S E N G I N E E R I N G C O M P A N Y The Ronan Series XPDM Programmable Digital Monitors are the latest generation of Ronan s state-of-the-art
More informationI/A Series 716C 1/16 DIN Temperature Controller
Product Specifications I/A Series 716C 1/16 DIN Temperature Controller PSS 2C-1B5 A The Foxboro 716C is a powerful compact, 1/16 DIN, microprocessor-based temperature controller that offers a variety of
More informationICS Regent. Fire Detector Input Modules PD-6032 (T3419)
ICS Regent Fire Detector Input Modules (T3419) Issue 1, March, 06 Fire detector input modules provide interfaces for 16 fire detector inputs such as smoke detectors, flame detectors, temperature detectors,
More informationY-Plant Alert. Alarm Annunciator and Sequence of Event Recording System. BU 04M01A02-01E-A
Y-Plant Alert Alarm Annunciator and Sequence of Event Recording System BU 04M01A02-01E-A www.yokogawa.com/us Y-Plant Alert TM Alarm Annunciator and Sequence of Event Recording System Mission critical facilities
More informationUDC 700 Universal Digital Controllers and Indicator Specifications
UDC 700 Universal Digital Controllers and Indicator Specifications 51-52-03-28 August 2002 Overview The UDC 700 is a 1/32 DIN (49 x 25 mm) controller which combines a high degree of technology and quality
More informationCONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.
CONsOlIDATOR 4 & 8 MulTI- C h ANNEl CONTROllERs ConsoliDator 4 Model PD940 ConsoliDator 4 Features Four 4-20 Four 4-20 Outputs ConsoliDator 8 Features Eight 4-20 Two 4-20 Outputs Common Features Four Pulse
More informationCarbon Monoxide Transmitter
Introduction The CO Transmitter uses an electrochemical sensor to monitor the carbon monoxide level and outputs a field-selectable 4-20 ma or voltage signal. The voltage signal may also be set to 0-5 or
More informationType 8001 PRIME MOVER CONTROLS INC. ALARM ANNUNCIATOR TYPE8001 FEATURES SB 8001B
PRODUCT BULLETIN SB 8001B Type 8001 ALARM ANNUNCIATOR TYPE8001 FEATURES 16 or 32 alarm points per flush mount enclosure Displays are backlit with long life LEDs and engraved to suit Dimmer controls built
More informationPD154 & PD158 VIGILANTE II ANNUNCIATORS Instruction Manual
PD154 & PD158 VIGILANTE II ANNUNCIATORS 8 Field Selectable Sequences All Common ISA Sequences 4 or 8-Point (Channel) Monitoring Free Replaceable Message Labels Type 4X, NEMA 4X, IP65 Front Universal Power
More information725 Series Alarm Annunciator Rev 24. RTK Series 725 Annunciator
Warning The 725 System described herein operates on a logic voltage of 24VDC and as standard 24VDC is used for the field contact supply voltage. External power supplies using higher voltage AC/DC primary
More informationMicro-DCI 4 Channel Indicator Totalizers Series 53IT5100
Micro-DCI 4 Channel Indicator Totalizers Series 53IT5100 Four Channels of Process Variable Bargraph Indication Four Channels of Integration and Digital Totalization An Alarm/Annunciator Summary Intuitive
More informationSIMATRIX NEO Modular Video Matrix
SIMATRIX NEO Modular Video Matrix SIMNEO-168 Modular Design Expandable up to 224 Video-Inputs, 32 Video-Outputs Up to 8 keyboards can be connected for control Multiple protocol driver for the direct control
More informationPump Logic User Manual CB-1000 P/N ILK-CB1000-1
Pump Logic User Manual CB-1000 P/N ILK-CB1000-1 STATEMENT OF LIMITED WARRANTY The limited warranty applicable to this product is set forth in USFilter Control Systems standard terms of sale that are made
More informationOxygen (O2) Single-Point Gas Detection System
Oxygen (O) Single-Point Gas Detection System DESCRIPTION Wall-mounted gas monitor with built-in oxygen (O) sensor, accepts one analog remote device such as a secondary gas sensor, temperature or humidity
More informationEOTec 2C32 Installation Guide
ControlNet Dual Ring Modules For the EOTec 2000 Series November 2008 Weed Instrument Company, Inc. 707 Jeffrey Way, P.O. Box 300 Round Rock, TX 78680-0300 USA Tel: 512-434-2850 Fax: 512-434-2851 E-mail:
More informationVariable Frequency Drive SERIES MP800 VFD
Metron Fire Pump Controls and Accessories Variable Frequency Drive SERIES MP800 VFD Metron Fire Pump Controllers conform to the latest requirements of National Fire Protection Association s Standard for
More information02/11/2015
MIC48 With RS 485 link Part number 89422418 Heating and / or cooling function 2 independent alarms Load break detection 2 setpoint which can be selected remotely Manual / automatic power adjustment RS
More informationINTELLIGENT FIRE ALARM CONTROL PANEL
INTELLIGENT FIRE ALARM CONTROL PANEL FX-2000 SERIES Description Mircom s FX-2000 Series Intelligent Analog Fire Alarm Control Panel is designed to provide maximum flexibility of analog system requirements
More informationIntelligent Single Loop Fire Alarm Control Panel
Intelligent Single Loop Fire Alarm Control Panel The CAX-CTL-1L Intelligent Single Loop Fire Alarm Control Panel is a member of the industry leading Axis AX Series Intelligent Fre Alarm Control Panels
More informationWindow facia fault annunciators
Window facia fault annunciators WAP Window Annunciator Panel 15.08.2017 Annunciators for panel mounting with 24 signal inputs Storage of the last state of inputs and sequence in the case of power failure
More informationAnnunciator unit. Application
Issued: April 1999 Status: April 1999 Version: B/09.11.2001 Data subject to change without notice Features Flexible, field-customizable 16-channel annunciator unit Alarm channels activated by normally
More informationZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL
ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL PRODUCT Specification FEATURES Designed To Meet The Requirements Of EN54 Expandable From 1 To 5 Loops As Standard A Variety Of Networking Options
More informationBE SURE POWER IS DISCONNECTED PRIOR TO INSTALLATION! FOLLOW NATIONAL, STATE AND LOCAL CODES. READ THESE INSTRUCTIONS ENTIRELY BEFORE INSTALLATION.
INSTALLATION INSTRUCTIONS FOR SYMCOM S CONTROL MODEL PC-05 BE SURE POWER IS DISCONNECTED PRIOR TO INSTALLATION! FOLLOW NATIONAL, STATE AND LOCAL CODES. READ THESE INSTRUCTIONS ENTIRELY BEFORE INSTALLATION.!
More information20 Light Remote Annunciator
Light Remote Annunciator Owner s Manual Surface Mount Flush Mount 94-95- Standard Annunciator 94-, 94-95-, 95-4- 4- Annunciator w/remote Relay Panel 4-, 4-4-, 4-49-, 49-49-, 49- Time Multiplexed Annunciator
More informationNitrogen Dioxide (NO2) Single-Point Gas Detection System
Nitrogen Dioxide (NO) Single-Point Gas Detection System DESCRIPTION Wall-mounted gas monitor with built-in nitrogen dioxide (NO)/diesel fume gas sensor, accepts one analog remote device such as a secondary
More informationProcess & TeMPerATUre UniversAl input DigiTAl MeTers
Process & TeMPerATUre UniversAl input DigiTAl MeTers nova PD56 series Thermocouple, rtd, & Process inputs Universal Power supply 1-24 va c Up to 3 Alarm relays retransmitting 4-2 ma output input Max/Min
More informationLDM Series Lamp Driver Modules For Graphic Annunciation and Control
12 Clintonville Road Northford, CT 06472 (203) 484-7161 FAX: (203) 484-7118 LDM Series Lamp Driver Modules For Graphic Annunciation and Control Used with the System 500, System 5000, AM2020/AFP1010 and
More informationAnnunciator Unit SACO 16 D1. Product Guide
Issued: Aprill 1999 Status: Updated Version: C/20.03.2006 Data subject to change without notice Features Flexible, field-customizable 16-channel annunciator unit Alarm channels activated by normally open
More informationFire control panels FC360
Cerberus TM FIT Fire control panels FC360 FC361-ZZ, FC361-ZA, FC361-YZ, FC361-YA Fire control panels (1-loop) for addressable peripheral devices with integrated operating unit One loop with 126 addresses
More informationGuide Specification Model CTG Automatic Transfer Switch
Guide Specification Model CTG Automatic Transfer Switch PART 1 GENERAL 1.1 Scope A. It is the intent of this specification to secure a transfer switch that has been prototype tested, factory built, production
More informationFire and Gas Monitoring Panel ST7-HV
Fire and Gas Monitoring Panel ST7-HV INTRODUCTION TO THE ST7-HV SYSTEM The ST7-HV system is a programmable PLC suitable for safety and security installations with a high technological and economic content
More informationPROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS
PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS NOVA PD56 Series Thermocouple, RTD, & Process Inputs Universal Power Supply 1-24 VAC Up to 3 Alarm Relays Retransmitting 4-2 ma Output Input Max/Min
More informationACCURATE ELECTRONICS INC PO BOX SW HALL BLVD BEAVERTON OR USA FAX
Page 1 of 10 Model 10807800 January 2014 ACCURATE ELECTRONICS INC PO BOX 1654 97075-1654 8687 SW HALL BLVD 97008 BEAVERTON OR USA 503.641.0118 FAX 503.646.3903 WWW.ACCURATE.ORG Practice Section 10807800
More informationModel LTN-3R Outdoor Rated Uninterruptible Power System Single Phase
Model LTN-3R Outdoor Rated Uninterruptible Power System Single Phase General Specification 550 VA/Watts 1300 VA/Watts 1.0 GENERAL This specification defines the electrical and mechanical characteristics
More informationM1000 Alarm Annunciator
Data Sheet Alarm Annunciator Reliable Supervision and Control 10 inputs with LED indications Supports both NO/NC input contacts 10 open collector outputs Built-in siren relay Text label for alarm descriptions
More informationAPPLICATION DATA SHEET
APPLICATION DATA SHEET Wed : www.saenchotesei.com WWW.-..UK Control Systems Transmitters Sensors Accessories TOCSIN 920 - Wall, 19 Rack or Panel Mounting Units - 110/230V 50/60Hz AC operation - 250 Addressable
More information02/11/2015
CTH 46 - CTD 43 / 46 CTD 46 Part number 89422108 CTH 46 Heating / cooling function Measurement and setpoint display CTD 43 Heating or cooling function Measurement display Measurement deviation display-setpoint
More informationSystem 57. An advanced World of intelligent gas detection system management
An advanced World of intelligent gas detection system management A World of control technology High precision, intelligent control Master / voted alarm options High packing density Flexible I/O configuration
More informationHRX Technical Manual. Version 1.2
HRX 5000 Technical Manual Version 1.2 Contents: Specification...2 Connectors...5 RS-485 Network Connectors (J6 and J7)...5 RS-232 to Printer (J19)...6 RS-232 to PC (J8)...7 TCP/IP...8 Power (J21)...9 Fire
More informationSystem 57. An advanced world of intelligent gas detection system management
An advanced world of intelligent gas detection system management A world of control technology High precision, intelligent control Master/voted alarm options High packing density Flexible I/O configuration
More informationDependable Solutions for Gas Detection
Dependable Solutions for Gas Detection Combustibles/Flammables Standard & Exotic Toxics Oxygen Enrichment/Deficiency Introduction to Sensidyne Established in 1983 - acquired by Schauenburg GmbH in April
More informationSECTION AUTOMATIC TRANSFER SWITCHES
SECTION 26 36 23 AUTOMATIC TRANSFER SWITCHES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. General provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,
More informationDATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D
DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION Fike s CyberCat 254 (P/N 10-066) is a state-of-the-art true intelligent digital peer-to-peer modular fire alarm control system.
More informationFeatures. Omni2 Door Warning Sign Alarm Annunciator DATASHEET. Model C1190B Door Warning Sign
Features DATASHEET Connects to multiple sensing instruments One/Two Channel Device Bright solid state LED Alarm Display Audible Alert (internal and external) High reliability, fully dual redundant alarm
More informationFX Intelligent Analog Fire Alarm Control Panel. Installation and Operation Manual
Advanced Life Safety Solutions Advanced Life Safety Solutions FX-2000 Intelligent Analog Fire Alarm Control Panel Canada 25 Interchange Way Vaughan, ON L4K 5W3 Tel: 905-660-4655 Fax: 905-660-4113 U.S.A.
More informationMATERIAL AND EQUIPMENT STANDARD FOR ALARM AND PROTECTIVE SYSTEMS FIRST EDITION MAY 2006
MATERIAL AND EQUIPMENT STANDARD FOR ALARM AND PROTECTIVE SYSTEMS FIRST EDITION MAY 2006 This Standard is the property of Iranian Ministry of Petroleum. All rights are reserved to the owner. Neither whole
More informationACCURATE ELECTRONICS INC
ACCURATE ELECTRONICS INC Page 1 of 7 Model 108078 2 Sept 09 WWW.ACCURATE.ORG PO BOX 1654 97075-1654 8687 SW Hall Blvd 97008 BEAVERTON OR USA 503.641.0118 FAX 503.646.3903 Practice Section 108078 Rev A
More informationSTATUS ALARM ALARM HISTORY POWER HISTORY RESET
Instruction Manual Model 1582-70L2 RF Switch June 2011, Rev. D CH1 AUTO CH2 SWITCH 1 2 1 2 STATUS 1 2 MODEL 1582 SWITCH CROSS TECHNOLOGIES INC. CH1 ONLINE MANUAL SELECT CH2 SWITCH MANUAL REMOTE ONLINE
More informationTechnical data MTL process alarm equipment. September 2016 INM RTK725 range rev 30. MTL RTK725 range. Alarm Annunciator
Technical data MTL process alarm equipment September 2016 INM RTK725 range rev 30 MTL RTK725 range Alarm Annunciator Safety Instructions The following methods are used in this manual to alert the user
More informationPanel Mounted Fault Annunciator Series
Panel Mounted Fault Annunciator Series BSM / USM Panel-mounted fault annunciator Annunciators for panel mounting with,,,, 0 and signal inputs Storage of the last state of inputs and sequence in the case
More informationINTELLIGENT FIRE ALARM CONTROL UNITS. MMX NDS Intelligent Network Fire Alarm Control Unit. Features. Description
INTELLIGENT FIRE ALARM CONTROL UNITS MMX-2003-12NDS Intelligent Network Fire Alarm Control Unit Description Secutron s MMX-2003-12NDS Network Fire Alarm Control Unit offers modular components to meet a
More informationUSER MANUAL FOR OPERATING SYSTEM
P2262 ALARM PANEL USER MANUAL FOR OPERATING SYSTEM 21765-07 September 1999 Associated Controls (Aust) PTY. LTD. 29 Smith Street, Hillsdale, NSW, 2036. PH (02) 9311 3255, FAX (02) 9311 3779 Page 1 of 177
More informationAnalog Annunciator Unit SACO 16 A3. Product Guide
Issued: Aprill 1999 Status: Updated Version: C/20.03.2006 Data subject to change without notice Features Powerful, flexible and field-customizable 16-channel analog input signal annunciator unit A full
More informationwww. ElectricalPartManuals. com Annunciator unit Features Self-contained microprocessor-based annunciator unit with 64 alarm channels Application
Features Self-contained microprocessor-based annunciator unit with 64 alarm channels pplication larm channels activated by normally open or normally closed contact Small and large stand-alone annunciator
More informationSpecification/ Data Sheet
Specification/ Data Sheet TRITON RP Agent Release Control Panel FEATURES Agent Release Control Panel designed specifically for suppression release operation with: Four initiating device circuits (IDCs)
More informationFire Control Panels. Multiple Signal Fiber Optic Modems and Accessories for 4120 Network. UL, ULC, CSFM Listed; FM Approved* Features
Fire Control Panels UL, ULC, CSFM Listed; FM Approved* Features Compatible with Simplex 4120 Network Converts multiple 4120 network communications signals into a single fiber optic link to: Multiplex audio
More informationINSTALLATION INSTRUCTIONS
TT-1343 5/06b INSTALLATION INSTRUCTIONS Original Issue Date: 8/03 Model: Automatic Transfer Switches Equipped with Series 1000 Programmable Controller Market: ATS Subject: Remote Annunciator Kits GM28938-KP1,
More information