Product Specification EMI Shielded Duplex LC Sealed Receptacle (ODVA Conforming)

Size: px
Start display at page:

Download "Product Specification EMI Shielded Duplex LC Sealed Receptacle (ODVA Conforming)"

Transcription

1 Product Specification EMI Shielded Duplex LC Sealed Receptacle (ODVA Conforming) 02Oct08 Rev A 1. SCOPE 1.1. Content This specification, based on IEC Edition 1.0 tests for Category E (Extreme Environment), covers the performance, tests and quality requirements for the Tyco Electronics EMI Shielded Duplex LC Sealed Receptacle (Open DeviceNet Vendor Association, Inc. (ODVA) Conforming) Qualification W hen tests are performed on the subject product line, procedures specified in Figure 2 shall be used. All inspections shall be performed using the applicable inspection plan(s) and product drawing(s) Qualification Test Results Successful qualification testing on the subject product line was completed on 24Apr08. The Qualification Test Report number for this testing is This documentation is on file at and available from Engineering Practices and Standards (EPS). 2. APPLICABLE DOCUMENTS The following documents form a part of this specification to the extent specified herein. Unless otherwise specified, the latest edition of the document applies. In the event of conflict between requirements of this specification and the product drawing, the product drawing shall take precedence. In the event of conflict between requirements of this specification and referenced documents, this specification shall take precedence Tyco Electronics Documents! : Quality Specification (Qualification of Fiber Optic Connectors and Cable Assemblies)! : Instruction Sheet (Sealed Circular LC Connector System - Plug Kit [] and Receptacle kit [])! : Qualification Test Report (EMI Shielded Duplex LC Sealed Receptacle (ODVA Conforming)) 2.2. Commercial Standards! IEC : Environmental Testing Part 1: General and Guidance! IEC 60529: Degrees of Protection Provided by Enclosures (IP Code)! IEC 61300: Fiber Optic Interconnecting Devices and Passive Components - Basic Test and Measurement Procedures! IEC 61726: Screening Attenuation Measurement by the Reverberation Chamber Method! IEC : Fiber Optic Connector Interfaces - Part 20: Type LC Connector Family! TIA/EIA-455-B: Standard Test Procedure for Fiber Optic Fibers, Cables, Transducers, Sensors, Connecting and Terminating Devices, and Other Fiber Optic Components 2008 Tyco Electronics Corporation Harrisburg, PA All International Rights Reserved. * Trademark Indicates change For latest revision, visit our website at For Regional Customer Service, visit our website at 1 of 10 LOC B

2 3. REQUIREMENTS 3.1. Design and Construction Product shall be of the design, construction and physical dimensions specified on the applicable product drawing(s) Optical Power Source Unless otherwise stated in the Qualification Test Report, the optical power source wavelength shall be 1310 ± 30 nm and 1550 ± 30 nm for singlemode Ratings Performance Value Singlemode Units Attenuation, typical (see Note) 0.06 db Return loss, typical (see Note) 56 db Operating temperature -40 to 85 C Storage temperature -40 to 85 C NOTE Typical values represent the median of the sample data. See Figure 2 for maximum insertion loss and minimum return loss requirements. Figure Performance and Test Description Product is designed to meet the mechanical, environmental and optical performance requirements specified in Figure 2. Unless otherwise specified, all tests shall be performed at ambient environmental conditions Test Requirements and Procedures Summary Test Description Requirement Procedure Visual and mechanical inspection. Meets requirements of product drawing. Duplex LC receptacle complies with dimensional requirements of IEC No defects which would affect functionality. IEC Visual, dimensional and functional per applicable quality inspection plan. See Note (a). Rev A 2 of 10

3 Test Description Requirement Procedure Attenuation (new product). Return loss (new product). Change in attenuation. Singlemode: For one mated connector pair: Average attenuation for the group/lot is 0.25 db. Maximum attenuation is 0.50 db for > 97% of specimens. Maximum attenuation is 0.75 db for 100% of specimens. Singlemode: specimen is 40 db for pigtail specimens (one mated connector pair). As applicable to each test: Singlemode: Maximum change in attenuation is 0.2 db during and after test for pigtail specimens (one mated connector pair). IEC Launch and receive are both part of the pair under test and are not reference quality. Precondition by cleaning plug and adapter per manufacturer's instructions. Test at 1310 ± 30 nm and 1550 ± 30 nm for singlemode. For singlemode, only the fundamental mode shall propagate at the connector interface and at the detector. See paragraph 5.1. IEC , branching device or OTDR method. Precondition by cleaning plug and adapter per manufacturer's instructions. Test at 1310 ± 30 nm and 1550 ± 30 nm for singlemode. See paragraph 5.1. IEC , Method 1. Record attenuation before, during and after test as applicable to each test. Measure attenuation at 1310 ± 30 nm and 1550 ± 30 nm for singlemode, unless otherwise specified. Calculate change in attenuation during test as the difference between the maximum and minimum attenuation values recorded during test (peak-to-peak range). Calculate change in attenuation after test as the difference between the initial reference recorded at the start of each test and the final reading recorded at the end of each test. Rev A 3 of 10

4 Test Description Requirement Procedure Shielding effectiveness. Change of temperature. Dependent upon customer specific application. specimen is 0.50 db before, during Maximum change in attenuation for any single specimen is 0.2 db during specimen is 40 db before, during IEC 61726, 2nd edition dated Based on IEC guidelines, use two mode-stirred chambers designed for a minimum frequency of 3 GHz. Mount the test bezel with the adapter in a common wall. Mode stir the receive chamber at 12 RPM and the drive side at 360 RPM. Mount a sense antenna in receive chamber and mount identical drive antennas in both chambers. Measure the peak power for one complete revolution of the slower (12 RPM) mode stirrer by first driving the cable board side drive antenna and then the cable side drive antenna. Calculate the ratio of these two values and report Cabinet Ambient Shielding Effectiveness (CA-SE) in db. Plot CA-SE from 1 to 15 GHz. IEC and IEC , Test Nb. Maintain specimens undisturbed in the chamber at room ambient (23 ± 5 C and 20 to 70% RH) for 2 hours prior to recording initial attenuation and return loss. A minimum of 3 m [9.8 ft] cable length shall be inside the test chamber (> 1.5 m [4.9 ft] on each side of the connector for pigtail specimens). Using a ramp rate of 1 C per minute, subject specimens to 12 cycles between -40 ± 2 C and 85 ± 2 C with 1 hour dwells at each extreme. Attenuation and return loss shall be measured before test, at a maximum interval of 10 minutes throughout the exposure, Maintain specimens undisturbed for at least 2 hours after the chamber's return to ambient conditions, before measuring final attenuation and return loss. See paragraph 5.2. Rev A 4 of 10

5 Test Description Requirement Procedure Temperature/humidity cycling. Mixed flowing gas. specimen is 0.50 db before, during Maximum change in attenuation for any single specimen is 0.2 db during specimen is 40 db before, during specimen is 0.50 db after test. specimen is 40 db after test. See Notes (b) and (c). IEC and IEC , Test Z/AD with exposure to cold. After pre-conditioning, maintain specimens undisturbed in the chamber at room ambient (23 ± 5 C and 20 to 70% RH) for 2 hours prior to recording initial attenuation and return loss. A minimum of 3 m [9.8 ft] cable length shall be inside the test chamber (> 1.5 m [4.9 ft] on each side of the connector for pigtail specimens). Profile temperature extremes are -10 ± 2 C and +65 ± 2 C, with 93 ± 3% RH at the maximum temperature. Dwell at each temperature extreme for 3 hours. Perform 10 total cycles, with cold shock included in 5 of the first 9 cycles. Attenuation and return loss shall be measured before test, at a maximum interval of 10 minutes during test Maintain specimens at ambient conditions for a minimum of 24 hours, before measuring final attenuation and return loss. See paragraph 5.2. IEC , Method hours duration, sulphur dioxide -9 (SO 2 500x10 ) and hydrogen -9 sulphide (H2S 100x10 ). The apparatus consists of a test chamber in accordance with IEC , Test Ke. Corrosive monitoring copper coupons shall be used. Mount receptacle to water-tight enclosure and tighten the receptacle panel nut to the appropriate torque specified in the Instruction Sheet. Subject specimen to the test in a non-operational mode with protective cover applied to the receptacle. Upon completion of the test, the specimen shall be examined visually and all observations recorded. Measure attenuation, return loss and EMI shielding effectiveness after test. See Note (c). Rev A 5 of 10

6 Salt mist. Test Description Requirement Procedure Durability (bayonet). specimen is 0.50 db after test. specimen is 40 db after test. specimen is 0.50 db before, during Maximum change in attenuation for any single specimen is 0.2 db during specimen is 40 db before, during IEC and IEC , Test Ka. 96 hours duration, salt solution 5% NaCl (ph between 6.5 and 7.2) at 35 C. Mount receptacle to water-tight enclosure and tighten panel nut to the appropriate torque specified in the Instruction Sheet. Subject specimen to the test in a non-operational mode with protective cover applied to the receptacle. Upon completion of the test, the specimen shall be examined visually and all observations recorded. Careful attention shall be given to look for cracking and delamination of finishes and phenomena such as scratches and pitting, which are indicative of the removal of the protective coating. Measure attenuation, return loss and EMI shielding effectiveness after test. IEC Subject specimen to 500 cycles. A cycle shall consist of one full engagement and separation of the coupling mechanism to be evaluated (unmate/mate sealed circular LC ODVA plug from receptacle). The minimum time between each engagement and separation shall be 3 seconds. Attenuation and return loss readings shall be recorded every 50 matings after cleaning. Rev A 6 of 10

7 Dust protection. Test Description Requirement Procedure Temporary water immersion. No observable ingress of dust past the panel mounting or within the receptacle upon test completion. specimen is 0.50 db after test. specimen is 40 db after test. No accumulated ingress of water within the enclosure and connector, which could reach live parts. specimen is 0.50 db after test. specimen is 40 db after test. See Notes (b) and (c). IEC 60529, International Protection Code IP6X, Category 1, 8 hour duration, talcum powder. Specimen configuration: unmated receptacle with cap. Mount receptacle to a panel and tighten the receptacle panel nut to the appropriate torque specified in the Instruction Sheet. Subject specimen to the test in a non-operational mode with protective cover applied to the receptacle. Talcum powder used shall be able to pass through a square-meshed sieve the nominal wire diameter of which is 50 m and the nominal width of a gap between wires is 75 m. Dust circulation shall attempt to draw dust to the other side of the mounting panel. Maximum atmospheric depression 2 kpa [0.29 psi]. Upon completion of the test, the specimen shall be examined visually and all observations recorded. Measure attenuation, return loss and EMI shielding effectiveness after test. IEC 60529, International Protection Code IPX7, 30 minutes. Specimen configuration: unmated receptacle with cap. Mount receptacle to water-tight enclosure of height less than 850 mm [33.5 in], and tighten the receptacle panel nut to the appropriate torque specified in the Instruction Sheet. Subject specimen to the test in a non-operational mode with protective cover applied to the receptacle. Immerse the enclosure, such that the lowest point is located 1000 mm [39.4 in] below the water surface and the highest point of the enclosure is a minimum depth of 150 mm [5.9 in] below the water surface. Upon completion of the test, the specimen shall be examined visually and all observations recorded. Measure attenuation, return loss and EMI shielding effectiveness after test. See Note (c). Rev A 7 of 10

8 Impact. Vibration. Test Description Requirement Procedure specimen is 0.50 db before and after test. Maximum change in attenuation for any single specimen is 0.2 db after test. specimen is 40 db before and after test. specimen is 0.50 db before and after test. Maximum change in attenuation for any single specimen is 0.2 db after test. specimen is 40 db before and after test. IEC , Method B. Subject unmated receptacle to 5 drops onto a steel plate from a height of 1.5 m [5 ft]. Randomize receptacle orientation for each drop. Measure attenuation and return loss before and after the test. Clean specimen before mating for final readings. See paragraph 5.1. IEC and IEC , Test Fc. Subject mated specimens to 15 sweeps over the frequency range of 10 Hz to 55 Hz and back to 10 Hz. Sweep rate shall be 1 octave per minute. Amplitude 0.75 mm. Specimen shall be vibrated in three mutually perpendicular axes. Measure attenuation and return loss before and after the test. Clean specimen before mating for final readings. See paragraph 5.1. NOTE (a) (b) (c) Dimensions not measured on actual test specimens are covered by First Article approval, which includes verification of product drawings per the dimensions specified in IEC Shall meet visual requirements, show no physical damage, and shall meet the requirements of additional tests as specified in the Product Qualification Test Sequence in Figure 3. Optical measurements after test may be delayed until the end of the test sequence. Figure 2 (end) Rev A 8 of 10

9 3.6. Product Qualification Test Sequence After visual and mechanical inspection, specimens shall first be tested for initial attenuation and return loss on new product, after which the remaining tests may be performed in any order. The groups and sequencing shown below is the suggested test plan. Test Groups (a) Test or Examination Test Sequence (b) Visual and mechanical inspection Attenuation 3,7 3,7 3 Return loss 4,8 4,8 4 Shielding effectiveness 2,5 2,9 2,9 2,8 Change of temperature 3 Temperature/humidity cycling 4 Mixed flowing gas 5 Salt mist 6 Durability (bayonet) 7 Dust protection 6 Temporary water immersion 5 Impact 5 Vibration 6 NOTE (a) (b) (c) Numbers indicate sequence in which tests are performed. See paragraph 4.1.A. A specimen consists of a mated duplex pair, except where noted in Figure 2 (such as a capped receptacle for sealing tests). Figure 3 4. QUALITY ASSURANCE PROVISIONS 4.1. Qualification Testing A. Specimen Selection Specimens shall be prepared in accordance with the applicable Instruction Sheets and shall be selected at random from current production. Specimen shall be defined as an EMI Shielded Duplex LC Sealed Receptacle that is ODVA conforming. B. Specimen Quantity Specimen quantity shall be a minimum of 5 for each individual test. C. Test Sequence Qualification inspection shall be verified by testing specimens as specified in Figure 3. Rev A 9 of 10

10 4.2. Requalification Testing If changes significantly affecting form, fit or function are made to the product or manufacturing process, product assurance shall coordinate requalification testing, consisting of all or part of the original testing sequence as determined by development/product, quality and reliability engineering Acceptance Acceptance is based on verification that the product meets requirements of Figure 2. Failures attributed to equipment, test setup or operator deficiencies shall not disqualify the product. When product failure occurs, corrective action shall be taken and specimens resubmitted for qualification. Testing to confirm corrective action is required before resubmittal Quality Conformance Inspection The applicable quality inspection plan will specify the sampling acceptable quality level to be used. Dimensional and functional requirements shall be in accordance with the applicable product drawing and this specification. 5. SPECIAL INSTRUCTIONS 5.1. Cleaning If at any time, a receptacle specimen is uncoupled from its LC connector test leads during qualification testing, the optical interfaces shall be cleaned according to the applicable Instruction Sheet prior to any subsequent optical measurements. Additional cleaning techniques deemed necessary by Product Engineering shall be described in the Test Report. If, after cleaning the connector as prescribed, loss performance exceeds the specified limit, or, if the operator suspects the presence of debris at the optical interface, perform the cleaning procedure a second time. If the resultant optical reading still exceeds the specification, clean the interface a third time and accept that reading Control Cables Control cables shall be subjected to climatic environmental tests. Transmittance shall be recorded each time a specimen transmittance is made. Changes in control cable power of less than 0.05 db may be neglected in the test specimen power and loss calculations. If control cable power changes by more than 0.05 db during the duration of the test or sequence of tests, change in control cable power should be included in power and loss calculations per TIA/EIA B. Rev A 10 of 10

Jul07 Rev C

Jul07 Rev C Product Specification 108-2167 11Jul07 Rev C MPO and MPO SECURE Multimode Fiber Optic Connector and Adapter 1. SCOPE 1.1. Content This specification, which is based on GR-1435-CORE, covers the performance,

More information

Jun08 Rev C

Jun08 Rev C Product Specification Connector, Card Edge,.050 Centerline 108-14034 02Jun08 Rev C 1. SCOPE 1.1. Content This specification covers performance, tests and quality requirements for Tyco Electronics.050 centerline

More information

Jun08 Rev A

Jun08 Rev A Product Specification Terminal Block Crimp Snap Plug Assembly 108-2319 09Jun08 Rev A 1. SCOPE 1.1. Content This specification covers performance, tests and quality requirements for the Tyco Electronics

More information

Jan05 Rev A EC

Jan05 Rev A EC Product Specification Two Circuit Heavy Duty Burner Connector 108-1056 12Jan05 Rev A EC 0990-0059-05 1. SCOPE 1.1. Content This specification covers performance, tests and quality requirements for the

More information

Mar11 Rev B

Mar11 Rev B Product Specification 108-1576-2 11Mar11 Rev B NETCONNECT*, CHAMP* System 5 Modular Jack Patch Panel 1. SCOPE 1.1. Content This specification covers performance, tests and quality requirements for NETCONNECT*

More information

Two Circuit Heavy Duty Burner Connector

Two Circuit Heavy Duty Burner Connector Product 108-1056 11 Oct.16 Rev B Specification EC 0990-0059-05 Two Circuit Heavy Duty Burner Connector 1. SCOPE 1.1. Content This specification covers performance, tests and quality requirements for the

More information

Mar11 Rev C

Mar11 Rev C Product Specification 108-1441 11Mar11 Rev C Connector, Z-PACK*, 2 mm FB, Signal and Power 1. SCOPE 1.1. Content This specification covers performance, tests and quality requirements for the Z-PACK* 2mm

More information

Apr06 Rev A

Apr06 Rev A Qualification Test Report LC, Multimode, One-Piece Housing, Fiber Optic Connector 501-628 03Apr06 Rev A 1. INTRODUCTION 1.1. Purpose 1.2. Scope Testing was performed on Tyco Electronics LC multimode, one-piece

More information

Qualification Test Report LightCrimp* Plus Singlemode and Multimode LC Connector (Field Installable)

Qualification Test Report LightCrimp* Plus Singlemode and Multimode LC Connector (Field Installable) Qualification Test Report LightCrimp* Plus Singlemode and Multimode LC Connector (Field Installable) 501-586 26Feb09 Rev F 1. INTRODUCTION 1.1. Purpose Testing was performed on Tyco Electronics LightCrimp*

More information

Qualification Test Report LC Duplex Adapter For LC Cutouts

Qualification Test Report LC Duplex Adapter For LC Cutouts Qualification Test Report LC Duplex Adapter For LC Cutouts 501-683 09Mar09 Rev B 1. INTRODUCTION 1.1. Purpose Testing was performed on Tyco Electronics LC Duplex Adapters for LC Cutouts, to determine their

More information

Jan07 Rev B

Jan07 Rev B Qualification Test Report 501-545 05Jan07 Rev B MT-RJ Patch Panel and Outlet Jacks (Standard, XG, SECURE and SECURE XG) 1. INTRODUCTION 1.1. Purpose Testing was performed on Tyco Electronics MT-RJ Jack,

More information

HMN-D2 Insert Series

HMN-D2 Insert Series HMN-D2 Insert Series Table of contents 1. SCOPE... 2 1.1. Content... 2 1.2. Qualification... 2 2. APPLICABLE DOCUMENTS... 2 2.1. TE Connectivity Documents... 2 2.2. Other Documents... 2 3. REQUIREMENTS...

More information

FEB. 17 Rev. A1

FEB. 17 Rev. A1 Product Specification 108-94552 10 FEB. 17 Rev. A1 The product described in this document has not been fully tested to ensure conformance to the requirements outlined below. Therefore, TE Connectivity

More information

PRODUCT SPECIFICATION. 0.5mm Fine Stacking. Hermaphroditic Type BTB Connector

PRODUCT SPECIFICATION. 0.5mm Fine Stacking. Hermaphroditic Type BTB Connector PRODUCT SPECIFICATION 108-115057 29OCT13 Rev. A1 0.5mm Fine Stacking Hermaphroditic Type BTB Connector 1. SCOPE 1.1. Content This specification covers performance, tests and quality requirements for 0.5mm

More information

Free Height 0.8 mm Pitch Board-to-Board Connector (SMT)

Free Height 0.8 mm Pitch Board-to-Board Connector (SMT) Product 108-5390 Specification 31 OCT 17 Rev.F1 Free Height 0.8 mm Pitch Board-to-Board Connector (SMT) 1. SCOPE 1.1. Contents This specification covers the requirements for product performance, test methods

More information

/Oct/2014 Rev B

/Oct/2014 Rev B Product Specification 108-93042 07/Oct/2014 Rev B Class EA shielded solid Patch cords 1. SCOPE 1.1 Content This specification describes performance and material requirements and tests procedures for TE

More information

Plug shell and receptacle, single cavity, floating, EN Application of modular rectangular modules and shells per EN4165

Plug shell and receptacle, single cavity, floating, EN Application of modular rectangular modules and shells per EN4165 PRODUCT SPECIFICATION Sep 22, 29 Rev. B CONNECTOR, SINGLE CAVITY, AEROSPACE, PANEL MOUNT, FLOATING, EN416 1 - SCOPE 1.1. Content This document covers the performances, tests, and quality requirements of

More information

/Oct/2014 Rev E

/Oct/2014 Rev E Product Specification 108-93017 14/Oct/2014 Rev E Cat 6 Unshielded Patch Cords 1. SCOPE 1.1 Content This specification describes performance and material requirements and tests procedures for TE Connectivity

More information

Cat 6 Shielded Patch cords

Cat 6 Shielded Patch cords Product Specification 108-93010 14/Oct/2009 Rev E Cat 6 Shielded Patch cords 1. SCOPE 1.1 Content This specification describes performance and material requirements and tests procedures for AMP NETCONNECT*

More information

Cat 6 Unshielded Patch cords

Cat 6 Unshielded Patch cords Product Specification 108-93017 13/Oct/2009 Rev D Cat 6 Unshielded s 1. SCOPE 1.1 Content This specification describes performance and material requirements and tests procedures for AMP NETCONNECT* Cat

More information

/Mar/2014 Rev A

/Mar/2014 Rev A Qualification Test Report 501-93038 21/Mar/2014 Rev A MPOptimate FO Microcassette 12 fiber MPO-12xLC/PC 1. INTRODUCTION 1.1 Purpose Tests performed on MPOptimate FO Microcassette 12 fiber MPO-12xLC/PC,

More information

Qualification Test Report. AMP-TWIST Series Jacks for Class EA systems

Qualification Test Report. AMP-TWIST Series Jacks for Class EA systems Qualification Test Report 501-93032 14/April/2011 Rev A AMP-TWIST Series Jacks for Class EA systems 1. INTRODUCTION 1.1 Purpose Qualification testing on AMP-TWIST* Series Jacks for Class E A Systems, to

More information

ETSI TS V1.2.1 ( )

ETSI TS V1.2.1 ( ) TS 100 783 V1.2.1 (2004-08) Technical Specification Transmission and Multiplexing (TM); Passive optical components; Fibre optic fusion splices for single-mode optical fibre transmission systems for indoor

More information

Draft ES V1.1.1 ( )

Draft ES V1.1.1 ( ) Standard Transmission and Multiplexing (TM); Passive optical components; Fibre optic mechanical splices for single-mode optical fibre communications systems; Common requirements and conformance testing

More information

ETSI TS V1.2.1 ( )

ETSI TS V1.2.1 ( ) TS 101 263 V1.2.1 (2004-07) Technical Specification Transmission and Multiplexing (TM); Passive optical components; Fibre optic mechanical splices for single-mode optical fibre communications systems for

More information

HOUSING ASSY 5 POS. HYBRID STD/JR POWER TIMER TAB & REC.

HOUSING ASSY 5 POS. HYBRID STD/JR POWER TIMER TAB & REC. 108-37065 Product Specification Rev. A 18-Jan-2007 Housing Assy 5p Hybrid Std./Jr. Power Timer Tab & Rec. DESIGN OBJECTIVES The product described in this document has not been fully tested to insure conformance

More information

USB 3.0 Plug & Receptacle

USB 3.0 Plug & Receptacle US 3.0 Plug & Receptacle 1. Scope: 1.1 Contents: This specification covers the requirements for product performance, test methods and quality requirements of Tyco Electronics Universal Serial us (US) consortium

More information

Product Specification JUL07 Rev. F. 1. Scope : 2. Applicable Documents: 3. Requirements : 1 of Contents. 2.1 AMP Specifications :

Product Specification JUL07 Rev. F. 1. Scope : 2. Applicable Documents: 3. Requirements : 1 of Contents. 2.1 AMP Specifications : 1. Scope : 1.1 Contents 11JUL07 Rev. F DDR S.O.DIMM Socket 200 Positions This specification covers the requirements for product performance, test methods and quality assurance provisions of DDR S.O.DIMM

More information

APR 17 Rev A

APR 17 Rev A Product Specification 108-130015 11 APR 17 Rev A ChipConnect Cable Assembly 1. SCOPE 1.1. Content This specification covers performance, test and quality requirements for the ChipConnect Cable Assembly

More information

Product Specification Qualification Test Report

Product Specification Qualification Test Report PS 88 / DMI PC SM / 6/5 DIAMOND Test & Calibration Laboratory STS 333 / SCS 11 Product Specification Qualification Test Report DMI PC SM DIAMOND SA Via dei Patrizi 5 CH-6616 LOSONE Tel. +41 91 785 45 45

More information

MODULAR CONNECTOR 154 (58 AND 96) POS, WATERPROOF PRODUCT SPECIFICATION

MODULAR CONNECTOR 154 (58 AND 96) POS, WATERPROOF PRODUCT SPECIFICATION MODULAR 154 (58 AND 96) POS, WATERPROOF PRODUCT SPECIFICATION 108-18965 Product Specification 108-18965 10.02. 2011 Rev C1 MODULAR 154 (58 AND 96) POSITION, WATERPROOF CONTENT : 1 PRODUCT OVERVIEW 1.1

More information

JUL 18 Rev A1

JUL 18 Rev A1 Qualification Test Report 501-166004 30 JUL 18 Rev A1 Mini USB-B Header, H-Type SMT 1. INTRODUCTION 1.1. Purpose Testing was performed on the Mini USB-B Header, H-Type SMT to determine if it meets the

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 61753-1-3 Edition 1.0 2014-05 Fibre optic interconnecting devices and passive components Performance standard Part 1-3: General and guidance for single-mode fibre optic connector

More information

Product Specification CAT 6 UNSHIELDED PATCH CORDS

Product Specification CAT 6 UNSHIELDED PATCH CORDS Product 108-93017 Specification 23/Nov/06 Rev. A CAT 6 UNSHIELDED PATCH CORDS 1. SCOPE 1.1 Content This specification describes performance and material requirements and tests procedures for NETCONNECT

More information

ITU-T L.404. Field mountable single-mode optical fibre connectors

ITU-T L.404. Field mountable single-mode optical fibre connectors I n t e r n a t i o n a l T e l e c o m m u n i c a t i o n U n i o n ITU-T L.404 TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU (08/2017) SERIES L: ENVIRONMENT AND ICTS, CLIMATE CHANGE, E-WASTE, ENERGY

More information

Product Specification Mono-Shape TM Mark II - 5mm Pitch I.D.C Connectors, For TAB Contacts - RAST5

Product Specification Mono-Shape TM Mark II - 5mm Pitch I.D.C Connectors, For TAB Contacts - RAST5 1. SCOPE 1.1 Content This specification covers performance, test and quality requirements for the Mono-Shape Mark II - 5 mm Pitch I.D.C. Connectors for Tab contacts. These connectors are designed and developed

More information

Technical Specification for the Mastic-Sealed Fiber-Optic Closure System (FOSC 300C)

Technical Specification for the Mastic-Sealed Fiber-Optic Closure System (FOSC 300C) Page 1 of 24 Prepared by: Chris Radelet R&D Department Manager Approved by: Pieter De Coster Product Manager for the Mastic-Sealed Fiber-Optic Closure System (FOSC 300C) The FOSC 300C closure system is

More information

Technical Specification for the Gel-Sealed Fiber-Optic Closure System (FOSC 450)

Technical Specification for the Gel-Sealed Fiber-Optic Closure System (FOSC 450) Page 1 of 26 Prepared by: Daniel Daems R&D Department Manager Approved by: P. De Coster Product Manager for the Gel-Sealed Fiber-Optic Closure System (FOSC 450) The FOSC 450 system is a fully mechanical

More information

MT-RJ Optical Fiber System Field Testing

MT-RJ Optical Fiber System Field Testing MT-RJ Optical Fiber System Field Testing Table of Contents INTRODUCTION... 3 TEST JUMPERS... 4 LAUNCH CONDITIONS... 4 MT-RJ TEST KITS... 5 MT-RJ SYSTEM TESTING: Fixed transmit and receive (SC or ST-style)

More information

Side Entry Insulation Damage Repair Sleeve (SEIDRS) Raychem Devices Products

Side Entry Insulation Damage Repair Sleeve (SEIDRS) Raychem Devices Products 1.0 Scope This specification covers the design, performance and qualification requirements for Raychem Side Entry Insulation Damage Repair Sleeve. 1.1 Description. Raychem SEIDRS covered by this specification

More information

LOVAG TEST INSTRUCTION IEC/EN

LOVAG TEST INSTRUCTION IEC/EN LOVAG TEST INSTRUCTION IEC/EN 60947-5-5 CONTROL CIRCUIT DEVICES AND SWITCHING ELEMENTS- ELECTRICAL EMERGENCY STOP DEVICE WITH MECHANICAL LATCHING FUNCTION This test instruction is based on the following

More information

Copper LAN cable. This specification describes the general requirements for AMP NETCONNECT* copper LAN cable.

Copper LAN cable. This specification describes the general requirements for AMP NETCONNECT* copper LAN cable. Product Specification 108-93018 25/Aug/2011 Rev H Copper LAN cable 1. SCOPE 1.1. Content This specification describes the general requirements for AMP NETCONNECT* copper LAN cable. 2. APPLICABLE DOCUMENTS

More information

SPECIFICATION AND PERFORMANCE MDP CONNECTOR SERIES

SPECIFICATION AND PERFORMANCE MDP CONNECTOR SERIES SPECIFICATION AND PERFORMANCE OF MDP CONNECTOR SERIES CIRCUIT ASSEMBLY CORP. 18 THOMAS STREET, IRVINE, CA 92618-2777 Page No. 1 of 16 CLAUSE CONTENTS PAGE 1.0 SCOPE... 3 2.0 APPLICABLE DOCUMENTS... 3 3.0

More information

CERTIFICATE of QUALITY TEST

CERTIFICATE of QUALITY TEST Testing laboratory for climatic, mechanical and corrosive environmental stress CERTIFICATE of QUALITY TEST Test report - No. 10142 / 13 Client ADDI-DATA GmbH Airpark Business Center Airport Boulevard B210

More information

Product Tests Report

Product Tests Report TO WHOM IT MAY CONCERN Page: 1 of 5 Product name: Model number and description: MIC IP starlight 7000i Product Tests Report MIC-7502-Z30B, PTZ camera 2MP HDR 30x IP68 IK10, black MIC-7502-Z30W, PTZ camera

More information

TEST REPORT Report No.: HN80013/2011 Page: 1 of 7 Date: August 30, 2011

TEST REPORT Report No.: HN80013/2011 Page: 1 of 7 Date: August 30, 2011 Page: 1 of 7 Date: August 30, 2011 GLACIALTECH INC. 9FL, NO. 352, SEC. 2, JUNG SHAN RD., JUNG HE CITY, TAIPEI, TAIWAN The following merchandise was submitted and identified by the vendor as: Product Description:

More information

VTI Services Technical Bulletin (TB) OTDR Measurement of Installed Optical Fibre Cabling Permanent Links and Links

VTI Services Technical Bulletin (TB) OTDR Measurement of Installed Optical Fibre Cabling Permanent Links and Links VTI Services Technical Bulletin (TB) OTDR Measurement of Installed Optical Fibre Cabling Permanent Links and Links TB Number 004 This bulletin is supplied for information only and is intended to provide

More information

COMITÉ EUROPÉEN DES ASSURANCES

COMITÉ EUROPÉEN DES ASSURANCES COMITÉ EUROPÉEN DES ASSURANCES SECRETARIAT GENERAL 3bis, rue de la Chaussée d'antin F 75009 Paris Tél. : +33 1 44 83 11 73 Fax : +33 1 44 83 11 85 Web : cea.assur.org DELEGATION A BRUXELLES Square de Meeûs,

More information

SECTION ULTRASONIC TRANSIT TIME CLAMP-ON FLOW MEASURING SYSTEM

SECTION ULTRASONIC TRANSIT TIME CLAMP-ON FLOW MEASURING SYSTEM SECTION 40 71 66 ULTRASONIC TRANSIT TIME CLAMP-ON FLOW MEASURING SYSTEM PART 1-GENERAL 1.01 SUMMARY A. Ultrasonic clamp-on flow measurement system designed for non-intrusive external to pipe measurement

More information

23" PANEL MOUNT INDUSTRIAL MONITOR REVISION C PRODUCT RELIABILITY TEST REPORT

23 PANEL MOUNT INDUSTRIAL MONITOR REVISION C PRODUCT RELIABILITY TEST REPORT 23" PANEL MOUNT INDUSTRIAL MONITOR REVISION C PRODUCT RELIABILITY TEST REPORT Model No. HIS-ML23- _ C Table of Contents Test Report Overview... 3 Testing Rationale...3 Test Plan...4 Test 1 Cold (Steady

More information

Fibre Optic Connector and Component Standards Developments & Key Issues in IEC & CENELEC. Philip C Longhurst Corporate Fibre Optic R & D Manager

Fibre Optic Connector and Component Standards Developments & Key Issues in IEC & CENELEC. Philip C Longhurst Corporate Fibre Optic R & D Manager Fibre Optic Connector and Component Standards Developments & Key Issues in IEC & CENELEC Philip C Longhurst Corporate Fibre Optic R & D Manager Outline CENELEC TC86BXA work programme IEC SC86B WG 6 and

More information

Vibration tests on a TNAML Luminaire

Vibration tests on a TNAML Luminaire Sebert Trillingstechniek B.V. Report M13.001-P13.001 rev.01 Date 26 august 2013 Vibration tests on a TNAML Luminaire Client Technor Benelux B.V. Veersteeg 15 4212 LR Spijk The Netherlands Contact Person

More information

17" UNIVERSAL MOUNT INDUSTRIAL MONITOR REVISION E, F & G PRODUCT RELIABILITY TEST REPORT

17 UNIVERSAL MOUNT INDUSTRIAL MONITOR REVISION E, F & G PRODUCT RELIABILITY TEST REPORT 17" UNIVERSAL MOUNT INDUSTRIAL MONITOR REVISION E, F & G PRODUCT RELIABILITY TEST REPORT Model No. HIS-UM17- _ E, HIS-UM17- _ F and HIS-UM17- _ G Table of Contents Test Report Overview... 3 Testing Rationale...3

More information

Qualification Testing of Nuclear High Voltage Splice (NHVS) Title Pages: 49. Report Number: EDR-5391 Rev. 0 06/15/05. Approved by: Signature: Date:

Qualification Testing of Nuclear High Voltage Splice (NHVS) Title Pages: 49. Report Number: EDR-5391 Rev. 0 06/15/05. Approved by: Signature: Date: Energy Report EDR-5391 Qualification Testing of Nuclear High Voltage Splice (NHVS) Title Pages: 49 Qualification Testing of Nuclear High Voltage Splice (NHVS) Enclosures: Report Number: Date: EDR-5391

More information

4120 Fire Alarm Network Reference

4120 Fire Alarm Network Reference 4120 Fire Alarm Network Reference Features Autocall 4120 Fire Alarm Network communications are available for wired or fiber optic connections Wired communications are available on Network Interface Cards

More information

GR-326-CORE Singlemode Optical Connectors and Jumper Assemblies

GR-326-CORE Singlemode Optical Connectors and Jumper Assemblies Preface...Preface 1 1. Introduction... 1 1 1.1 Purpose and Scope... 1 1 1.2 Target Audience... 1 2 1.3 Structure and Use of This Document...1 2 1.4 Changes from Issue 2 of GR-326-CORE... 1 3 1.5 Requirements

More information

ISO INTERNATIONAL STANDARD. Agricultural engineering Electrical and electronic equipment Testing resistance to environmental conditions

ISO INTERNATIONAL STANDARD. Agricultural engineering Electrical and electronic equipment Testing resistance to environmental conditions INTERNATIONAL STANDARD ISO 15003 First edition 2006-02-15 Agricultural engineering Electrical and electronic equipment Testing resistance to environmental conditions Génie agricole Matériel électrique

More information

Qualification Test Report 1/Jul/2005 Rev. A

Qualification Test Report 1/Jul/2005 Rev. A Qualification Test 501-93013 Report 1/Jul/2005 Rev. A AMP CO 10 Gigabit/s Insert PN 1711188-X 1. INTRODUCTION 1.1 Purpose Testing was performed on AMP* CO 10 Gigabit/s Insert, to determine its conformance

More information

INTERNATIONAL TELECOMMUNICATION UNION SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE PLANT

INTERNATIONAL TELECOMMUNICATION UNION SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE PLANT INTERNATIONAL TELECOMMUNICATION UNION ITU-T L.36 TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU (10/98) SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE PLANT

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 60539-1 QC 430000 First edition 2002-02 Directly heated negative temperature coefficient thermistors Part 1: Generic specification Thermistors à coefficient de température négatif

More information

Inverted Through Board Surface

Inverted Through Board Surface Inverted Through Board Surface Application Specification Mount Technology (SMT) 114-13245 Connector Assembly 14 DEC 09 Rev E NOTE i All numerical values are in metric units [with U.S. customary units in

More information

Link loss measurement uncertainties: OTDR vs. light source power meter By EXFO s Systems Engineering and Research Team

Link loss measurement uncertainties: OTDR vs. light source power meter By EXFO s Systems Engineering and Research Team Link loss measurement uncertainties: OTDR vs. light source power meter By EXFO s Systems Engineering and Research Team INTRODUCTION The OTDR is a very efficient tool for characterizing the elements on

More information

SECTION (16460) - LOW-VOLTAGE TRANSFORMERS

SECTION (16460) - LOW-VOLTAGE TRANSFORMERS PART 1 GENERAL 1.01 SUMMARY SECTION 26 22 00 (16460) - LOW-VOLTAGE TRANSFORMERS A. Section Includes: 1. Dry-Type Distribution And Specialty Transformers Rated 1000 V And Less. a. General-Purpose Distribution

More information

ENVIRONMENTAL TEST REPORT

ENVIRONMENTAL TEST REPORT MECHANICAL TESTING 0839.04 Hermon Laboratories Ltd. Harakevet Industrial Zone, Binyamina 30500, Israel Tel. +972-4-6288001 Fax. +972-4-6288277 E-mail: mail@hermonlabs.com ENVIRONMENTAL TEST REPORT ACCORDING

More information

Hydraulic Crimping Head, PN

Hydraulic Crimping Head, PN ORIGINAL INSTRUCTIONS Hydraulic Crimping Head, PN 1752868-1 Instruction Sheet 408-8959 19 JUL 17 Rev C 1. INTRODUCTION Figure 1 This instruction sheet covers application, inspection and maintenance procedures

More information

Compliance with EN : 2006 Electrical apparatus for explosive atmospheres Type of Protection «n» for Zone 2

Compliance with EN : 2006 Electrical apparatus for explosive atmospheres Type of Protection «n» for Zone 2 Compliance with EN60079-15: 2006 Electrical apparatus for explosive atmospheres Type of Protection «n» for Zone 2 RJ11FTVX series: rugged and sealed RJ11/12 connectors Report Prepared by : Amphenol Socapex

More information

The Rise of Tier 2 Testing

The Rise of Tier 2 Testing The Rise of Tier 2 Testing Why enterprises today demand better visibility into their fiber infrastructure Unprecedented demand for more bandwidth, faster network speeds, lower latency, and improved data

More information

Hydraulic Crimping Heads and

Hydraulic Crimping Heads and Hydraulic Crimping Heads 58422-1 and 2161730-1 Instruction Sheet 408-9535 30 MAY 17 REV D 1. INTRODUCTION Figure 1 This instruction sheet covers application, inspection and maintenance procedures for Crimping

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 61051-1 QC 420000 Second edition 2007-04 Varistors for use in electronic equipment Part 1: Generic specification Commission Electrotechnique Internationale International Electrotechnical

More information

TEST REPORT Reliability Laboratory Report No.: HCD0203/2008

TEST REPORT Reliability Laboratory Report No.: HCD0203/2008 Reliability Laboratory Page: 1 of 5 Date: December 23, 2008 WINMATE COMMUNICATION INC. 9 F, NO. 111-6, SHING-DE RD., SAN-CHUNG CITY, TAIPEI, TAIWAN, R.O.C. The following merchandise was submitted and identified

More information

SolderSleeve Insulated Electrical Termination Devices

SolderSleeve Insulated Electrical Termination Devices Tyco Electronics Corporation 300 Constitutional Drive Menlo Park, CA 94025 USA Specification This Issue: Date: Replaces: RT-1404 ISSUE 9 April 20, 2000 ISSUE 8 1.0 INTRODUCTION SolderSleeve Insulated Electrical

More information

Special Provision No. 683S28 December 2017

Special Provision No. 683S28 December 2017 FIBRE OPTIC COMMUNICATION CABLES, AERIAL ON MESSENGER CABLE - Item No. FIBRE OPTIC COMMUNICATION CABLES, AERIAL ON MESSENGER CABLE (TEMPORARY) - Item No. Special Provision No. 683S28 December 2017 1. SCOPE

More information

SECTION GENERATOR PARALLELING CONTROLS

SECTION GENERATOR PARALLELING CONTROLS PART 1 - GENERAL 1.1 DESCRIPTION SECTION 26 23 13 GENERATOR PARALLELING CONTROLS SPEC WRITER NOTE: Delete between // -- // if not applicable to project. Also delete any other item or paragraph not applicable

More information

Hydraulic Crimping Head, PN

Hydraulic Crimping Head, PN Hydraulic Crimping Head, PN 1673672-1 Instruction Sheet 408-8910 14 JUL 17 Rev C PROPER USE GUIDELINES Cumulative trauma disorders can result from the prolonged use of manually powered hand tools. Hand

More information

ECP OPTICAL FIBRE SPLICING, TESTING AND COMMISSIONING REQUIREMENTS

ECP OPTICAL FIBRE SPLICING, TESTING AND COMMISSIONING REQUIREMENTS Network(s): Summary: ENGINEERING COMMISSIONING PROCEDURE ECP 11-0009 OPTICAL FIBRE SPLICING, TESTING AND COMMISSIONING REQUIREMENTS EPN, LPN, SPN This standard details the requirements for the splicing,

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 60738-1 QC 440000 Second edition 1998-11 Thermistors Directly heated positive step-function temperature coefficient Part 1: Generic specification Thermistances à basculement

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 61755-2-4 Edition 1.0 2015-01 colour inside Fibre optic interconnecting devices and passive components Connector optical interfaces Part 2-4: Connection parameters of non-dispersion

More information

This is a preview - click here to buy the full publication

This is a preview - click here to buy the full publication ISO/IEC 14763-3 CONSOLIDATED VERSION Edition 2.1 2018-08 colour inside Information technology Implementation and operation of customer premises cabling Part 3: Testing of optical fibre cabling INTERNATIONAL

More information

DRAFT TANZANIA STANDARD

DRAFT TANZANIA STANDARD EEDC 4 (5157) P3 IEC 62599-1: 2010 DRAFT TANZANIA STANDARD (Draft for comments only) Alarm systems Part 1: Environmental test methods TANZANIA BUREAU OF STANDARDS TBS 2017 First Edition 2017 0 National

More information

Hydraulic Crimping Head, PN 69069

Hydraulic Crimping Head, PN 69069 Hydraulic Crimping Head, PN 69069 Instruction Sheet 408-1745 31 JUL 17 Rev F 1. INTRODUCTION Figure 1 This instruction sheet covers application, inspection and maintenance procedures for DYNA-CRIMP* Crimping

More information

M7100 Pressure Transducer

M7100 Pressure Transducer SPECIFICATIONS Performance standard on and off highway engine and vehicle OEMs Rugged for heavy equipment and outdoor use Designed specifically for high volume applications Stainless steel wetted surfaces

More information

SOLARLOK Interconnection System Installation Manual

SOLARLOK Interconnection System Installation Manual SOLARLOK Interconnection System 1. Safety Note! n The SOLARLOK connector is to be used only to interconnect firmly fixed cables. n Do not disconnect under electrical load! n Electrical current path should

More information

SECTION ISOLATED POWER SYSTEMS

SECTION ISOLATED POWER SYSTEMS PART 1 - GENERAL 1.1 DESCRIPTION SECTION 26 20 11 ISOLATED POWER SYSTEMS SPEC WRITER NOTE: Delete between //---// if not applicable to project. Also, delete any other item or paragraph not applicable to

More information

This instruction sheet covers the Hand Crimping Tools listed in Figure 1, which are used to crimp the terminal types listed in Figure 2.

This instruction sheet covers the Hand Crimping Tools listed in Figure 1, which are used to crimp the terminal types listed in Figure 2. Figure 1 This instruction sheet covers the Hand Crimping Tools listed in Figure 1, which are used to crimp the terminal types listed in Figure 2. Reasons for reissue are provided in Section 9, REVISION

More information

2016 CDM Smith All Rights Reserved July 2016 SECTION FIBER OPTIC DATA NETWORK

2016 CDM Smith All Rights Reserved July 2016 SECTION FIBER OPTIC DATA NETWORK PART 1 GENERAL 1.01 SCOPE OF WORK SECTION 27 12 23 FIBER OPTIC DATA NETWORK A. Furnish, install, terminate, and test all fiber optic equipment and cabling necessary for a complete and functional data highway

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 61300-3-6 Second edition 2003-02 Fibre optic interconnecting devices and passive components Basic test and measurement procedures Part 3-6: Examinations and measurements Return

More information

This document is a preview generated by EVS

This document is a preview generated by EVS INTERNATIONAL STANDARD IEC 60748-23-1 QC 165000-1 First edition 2002-05 Semiconductor devices Integrated circuits Part 23-1: Hybrid integrated circuits and film structures Manufacturing line certification

More information

SECTION P01 LIGHTING AND APPLIANCE PANELBOARDS - A-SERIES

SECTION P01 LIGHTING AND APPLIANCE PANELBOARDS - A-SERIES PART 1 GENERAL A. The requirements of the Contract, Division 1, and Division 16 apply to work in this Section. 1.01 SECTION INCLUDES A. Lighting and appliance panelboards 1.02 RELATED SECTIONS A. 16475,

More information

Application Specification MAG-MATE* Poke-In Tab Terminals

Application Specification MAG-MATE* Poke-In Tab Terminals Application Specification MAG-MATE* 114-2050 Poke-In Tab Terminals 30 MAR 07 Rev G1 NOTE i All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 62341-5-2 Edition 2.0 2019-03 colour inside Organic light emitting diode (OLED) displays Part 5-2: Mechanical endurance test methods INTERNATIONAL ELECTROTECHNICAL COMMISSION

More information

This is a preview - click here to buy the full publication. High-voltage switchgear and controlgear

This is a preview - click here to buy the full publication. High-voltage switchgear and controlgear IEC/PAS 62271-109 Edition 1.0 2002-07 High-voltage switchgear and controlgear Part 109: Alternating-current series capacitor by-pass switches PUBLICLY AVAILABLE SPECIFICATION INTERNATIONAL ELECTROTECHNICAL

More information

Reasons for reissue are provided in Section 6, REVISION SUMMARY.

Reasons for reissue are provided in Section 6, REVISION SUMMARY. Reasons for reissue are provided in Section 6, REVISION SUMMARY. The FRONT OF TOOL has the AMP marking on the link. The BACK OF TOOL (Wire Side), into which the wire is inserted, has the wire size marked

More information

Wet alarm valve stations

Wet alarm valve stations VdS Guidelines for water extinguishing systems VdS 2100-01en Requirements and test methods VdS 2100-01en : 2011-05 (02) Publishing house: VdS Schadenverhütung GmbH Amsterdamer Str. 172-174 50735 Köln,

More information

FT702LT Turbine control wind sensor gives durability a new meaning FT702LT. series

FT702LT Turbine control wind sensor gives durability a new meaning FT702LT. series FT702LT Turbine control wind sensor......gives durability a new meaning FT702LT series Proven High Availability The FT702LT ultrasonic anemometer is the result of FT Technologies 10 years of experience

More information

Rules for Classification and Construction Additional Rules and Guidelines

Rules for Classification and Construction Additional Rules and Guidelines VI Rules for Classification and Construction Additional Rules and Guidelines 7 Guidelines for the Performance of Type Approvals 7 Test Requirements for Statical Converters with Semi-Conductors Edition

More information

TEMPORARY IMMERSION AND DUST TEST REPORT

TEMPORARY IMMERSION AND DUST TEST REPORT Report No. :DH1510130042A Version:A TEMPORARY IMMERSION AND DUST TEST REPORT Company Address :GradConn Ltd. :No. 139 Wuhan Rd., Longtan Township, Taoyuan County, Taiwan Sample Name :Refer to see page 2

More information

Fire Control Panels. Multiple Signal Fiber Optic Modems and Accessories for Panel and Remote Mounting. Features. Operation.

Fire Control Panels. Multiple Signal Fiber Optic Modems and Accessories for Panel and Remote Mounting. Features. Operation. UL, ULC Approved* Fire Control Panels Multiple Signal Fiber Optic Modems and Accessories for Panel and Remote Mounting Features Converts multiple fire alarm communications signals into a single fiber optic

More information

SECTION Fluorescent Dissolved Oxygen Measuring System

SECTION Fluorescent Dissolved Oxygen Measuring System SECTION 40 75 43 Fluorescent Dissolved Oxygen Measuring System PART 1 General 1.01 SUMMARY A. Requirements for a high-performance, digital fluorescence sensor for measurement of dissolved oxygen in liquid.

More information

Type approval testing of miscellaneous smoke and heat detectors for marine applications

Type approval testing of miscellaneous smoke and heat detectors for marine applications We help ideas meet the real world DELTA Test Report TEST Reg. no. 19 Type approval testing of miscellaneous smoke and heat detectors for marine applications Performed for Consilium Marine AB DANAK-199842

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 60068-2-52 Edition 3.0 2017-11 Environmental testing Part 2-52: Tests Test Kb: Salt mist, cyclic (sodium chloride solution) INTERNATIONAL ELECTROTECHNICAL COMMISSION ICS 19.040

More information