1

2 546 In-Line Submersible Patented ultra-stable Axial Ion Path reference cell. Sulfide, oxidizer, and poison proof! Chemically resistant CPVC, KYNAR, Polypropylene or PEEK body 300 psig insertion system C max temperature 546 sensors and assembly parts are interchangeable with ABB TBI-Bailey Models TB556 and TBX556 ph and ORP The Platinum Bullet - ORP Solid Platinum billet non-glass electrode Flat tip eliminates breakage, reduces build up and simplifies cleaning. Longer lasting, minimal maintenance and customer convenience Patented ultra-stable Axial Ion Path reference cell. Sulfide, oxidizer, and poison proof! 547 Ball Valve Insertion Assembly The Ball Valve Insertion Assembly is our most popular installation system for the 547 cartridge. This allows maintenance and replacement of the sensor without shutting off the process line or draining the tank. Operationally rated to 100 psig. Insertion depths, materials and cleaning systems are customer selectable to insure the best measurement with the lowest total cost of ownership. Hardware interchangeable with ABB/TBI-Bailey 557 systems. The Pressure Monster Tested and certified to 2,500 psig! Chemically resistant CPVC, KYNAR, Polypropylene or Peek sensor cartridge Armored Hi-Pressure body made from SS316, Titanium or Hastelloy C Can be equipped to provide triple redundancy against toxic gas escape Patented ultra-stable Axial Ion Path reference cell. Sulfide, oxidizer, and poison proof! Quick Change Patented Axial Ion Path reference cell. Sulfide, oxidizer, and poison proof! Chemically resistant CPVC, KYNAR or Polypropylene body 300 psig Quick-change hardware C max temperature Ideal for sample lines and valved side-streams 551 sensors and assembly parts are interchangeable with ABB TBI-Bailey Models TB551 and TBX551 sensors Electrode & Tip Protection Options Dual Notched Tips Impact protection with easy cleaning Recessed Tips Maximum protection Mining and abrasives Flush Tips Pulp streams, and auto-cleaning systems

3 Transmitters Stratos Pro A2 & A4 The Universal Analyzer : Accepts Memosens, ISM, and digital sensors, as well as classic electrochemical ph/orp, 2- and 4- electrode, and inductive conductivity, and electrochemical oxygen sensors. The backlit display of the Stratos Pro changes between six different colors to clearly signal operating states, reducing the risk of operator error during analyzer maintenance. 2 wire loop powered or 4 wire mains powered versions HART, on all models ATEX Zone 1, FM/CSA Class 1, Div 1 / Div 2 option Stratos ECO 2405 Industrial performance at a commodity price! Industrial 4-wire transmitter for ph/orp, conductivity, and electrochemical oxygen. FM/CSA Class 1, Div 2 approval On-board limit controller 2 analog outputs for measurement variable and temperature Full diagnostic suite for analyzer and sensor NEMA 4X, PBT enclosure For pipe, panel, or rail mount Stratos e-2000 transmitters Protos 3400 The Protos 3400 measuring system is a modular hardware and software concept for liquid analysis, and offers flexible solutions precisely tailored to the measuring task. It is possible to easily measure several process variables simultaneously, such as ph/cond, ph/ph, Cond/Oxy etc. with the appropriate configuration. Similar to a PC, the device is fitted with 3 slots, and can be retrofitted or modified at any time. FM/CSA Class 1, Div 2 Portamess 911 Portable ph Analyzer Calimatic automatically recognizes the right buffer automatic calibration at the press of a button 8 buffer sets to choose from Simultaneous ph/mv and temperature display Automatic device test during power-on Sensoface electrode monitoring Temperature detection with automatic Pt 1000 / NTC 30 kohm recognition 2000 operating hours on just 3 AA batteries Battery indicator Auto switch-off EMC design Portamess 913 Portable ph Analyzer 2-wire loop powered or 4-wire mains powered FM/CSA IS Class 1, Div 1, and Div 2, groups A, B, C, D ATEX II 2 (1) G EEx ib [ia] IIC T6 Hart, Profibus, Fieldbus On-board PID controller NEMA 4X, PBT enclosure Wall, pipe, or rail mount Diagnostic suite for both transmitter and sensor Sensor auto-cleaning relay 3 year warranty! Same features as 911, plus Integrated real-time clock, with date stamp. 1-, 2-, and 3-point calibration. Manual memory storage. Automatic recording of measured values over longer periods. Serial interface. Convenient. Paraly SW 109 transfer software. Transfers measured values to a PC. 2

4 Oxygen - Gas and Dissolved Phase OXY IDEAL FOR: Boiler Feed Water Gas Concentration Breweries and Wineries Tank Purging Packaging Hazardous Area Approval FM/CSA Class 1, Div 2 Gas Phase range from.5 ppm to 100% v/v Dissolved Oxygen range from 1 ppb up to 45 ppm Optical Fluorescence Technology Excellent long-term stability and low maintenance Normal calibration quarterly to yearly More than 100,000 data points without drift No membranes or chemical consumables Serviceable sensor element lifetime up to 5 years Quick response - full reaction and stabilization to T90 in less than 90 seconds. Robust Stainless Steel NEMA 4X Enclosure options. Wide range of sensor installation options, including: 12 mm PG13.5 Ball-valve insertion 3/4 MNPT or Quick-change in-line Custom sensors available Signal independent of flow velocity Not affected by electrical interferences and magnetic fields Not affected by pressure changes Pressure Capability to 2,500 PSI 3

5 PDO 2 Optical Oxygen Sensor Sensor configurable for Electrochemical, 4-20mA, or RS485 output Hi-temp, Lo-loss cable VP-8 Quick disconnect Available in standard BAT body forms, including 546, 551, 547 Body material Polypropylene for best price/process match 546 model includes 3/4 Threaded In-line insertion depths 1 1/2 suitable for jet-cleaner Replaceable O-ring sealed lumiphore tip for easy maintenance Wide temperature capability: -10C to 30C Applications: Waste Water control and monitoring Mid to hi-level O2 monitoring and control Submerged, threaded in-line, Quick-change, and Ball valve-insertion models Dissolved Oxygen - PDO 2 Specifications: Single-Input Classic Configuration 100 psig in-line, 175 psig with Hi-pressure system 30 0 C (auto shut off at 80 0 C)- Polypropylene See chemical compatibility chart for body material choice See pressure / temperature charts for specific limitations Benefits: Numerous connection options Connect via wire or wireless to standard single-or multi input analyzer/controller, or direct to DCS Connect to customer s existing traditional membrane-style transmitter High pressure capability: -1 to 175 psi (impulses to 80BAR) BOS-2 lumiphore LLD 15ppb, 0.05% to 30% Oxygen/Air Saturation Not affected by H 2 S, CO 2, SO 2 Industrial Construction Tolerant of hydrocarbons, and other common industrial chemicals Adaptive sampling rate Longer lumiphore life, 1 to 3 years Options: Wired or wireless operation Jet cleaner Optional cable lengths via VP-8 connector Portable calibrator Wired or Wireless 1401 OXY Multi-Input Configuration Any combination of Wired or Wireless Replacement for Membrane Sensor Wired only Customer s Existing E-chem transmitter 1401DO Oxygen Analyzer 4-wire Industrial Oxygen Analyzer Power: VDC, VAC/DC, VAC, HZ User-friendly menu structure User configurable On-board diagnostic suite Outputs: 2 X 0/4-20 ma or 0-10V 2 Relays - Control + Rinse Input: PDO 2 Sensor Binary for Key lock, Hold, or Alarm stop Display units: ppm, mg/liter, % saturation NEMA 4X enclosure Wall, pipe, or panel mount Economically priced single-input system Warranty: 1 year 4

6 Conductivity Sensors Boiler Feed 4-Electrode Conductivity Sensor 4-Electrode, ultra stable, coating tolerant design Insulator - Industrial Sapphire High Pressure - High Temperature o F ( C) Hi-Performance 4-Electrode Conductivity Sensor Hi-performance 4-electrode contacting conductivity sensor Self-compensating for corrosion and scale build-up Ultra-stable measurement Installation options - threaded in-line, submersible, quick-change or ball-valve insertion style Uses standard Barben Analyzer installation systems Toroidal Conductivity Sensors BAT Toroidal Conductivity Sensors are low maintenance wide range conductivity measurement cells for inline, valve insertion and submersible applications. The toroidal design provides a wide range of chemical compatibilities and is highly resistant to scaling and other forms of performance loss due to chemical coating. High Pressure, High Temperature 2-Electrode Conductivity Sensor Hi-Temp, Hi-Pressure, perfect for boiler applications PSIG Supplied standard with 8 integral lead and terminal strip 3/4 MNPT process connection In-Line and Submersible 2-Electrode Conductivity Sensors General purpose 2 electrode conductivity sensors Wide range of installation options Low-cost, economical configurations Wide range of cell constants to suit most conductivity ranges, and work with most transmitters 5

7 Suspended Solids/Turbidity Suspended Solids - S10, S20, S40 2 pairs of infrared light emitting diodes & photo-detectors pulsed in sequence Ratiometric signal processing compensates for changes due to aging and surface coating Effects of color, temperature and changes in background ambient light are virtually eliminated S10, S20, and S40 selectable to cover 0-25 g/l TSS MSSD53 microprocessor based transmitter provides both relay and/or analog outputs Auto-clean options Immersion Hygienic S10 S20 S40 Turbidity Sensor - T30 Ratiometric signal processing compensates for changes in the optical properties of the emitters and detectors due to ageing and surface coating Effects of color, temperature and changes in background ambient light are virtually eliminated 0-1,000 NTU (5 NTU LLD) The T30 sensor is designed for use with the Quadbeam MSSD53 microprocessor based transmitter MSSD53 Microprocessor based transmitter provides both relay and/or analog outputs Auto jet-spray feature standard Suspended Solids and Turbidity Transmitter - MSSD53 The MSSD53 transmitter is an advanced microprocessor based instrument for use with Barben Analyzer suspended solids & turbidity sensors. The instrument is supplied as standard with typical entry level defaults in the configuration program. Only the measurement range, probe signals, current output and alarm levels have to be entered for the unit to be commissioned. However, with a simple menu driven operator interface the full potential of the MSSD53 can be used to quickly set up any measurement strategy. Sludge Blanket Controller - MSSD33 The MSSD33 transmitter is an advanced microprocessor based suspended solids controller capable of accurately controlling and determining the sludge blanket level. 6

8 Accessories JB40 Integral Filtration System 10 micron filter excludes most coatings Submersion, In-Line or Flow-cell options Automatic Blow-back capability Replaceable filter element Uses 551 Quick-change sensor Polypropylene body & SS316 filter Hastelloy option Jet Spray Cleaners for ph Sensors Improves sensor life Reduces cleaning labor Reduces handling damage Improves responsiveness Eliminates dehydration Wetted Materials: SS 316, Kynar, CPVC, Titanium Use with B4 fluid distribution unit & Stratos 2402pH controller Fluid Distribution Unit The BAT B40/41 Fluid Distribution Unit allows you to operate your jet cleaner or mechanical scrubber with a minimum of assembly or maintenance time. Designed to connect between a local pressurized water or air line and your BAT auto-cleaning system, the B40/41 is a perfect companion to our Stratos or Protos Analyzers with on-board cleaning timers and control relays. Custom Sample Panels Hi-Purity Flow Cell SS 316 body provides EMF shielding Controls water impingement on electrode 1/4 inlet and outlet Holes for panel mounting Utilizes proven BAT 547 sensor cartridge Hi-Pressure Ball Valve Insertion System Insertion system for hi-pressure process lines or vessels Reduced insertion pressure in slurries and scaling processes Integral reaction housing with flush ports to facilitate cleaning and calibration Utilizes standard 546 sensors Double O-rings for retention process Anti-blowout flange for improved safety Sensor Scrubber Pot The BAT Sensor Pot allows you to submerge your sensor and scrubber assembly in a wet/dry sewer line, insuring that the sensor is kept hydrated while keeping the tip clean and free of biologic sludge or other buildup. Available in either PVC or Stainless, with 1 or 2 inlet and outlet. Sensor Extension Cables B39, B68 and VP8 Extension cables allow you to specify a single ph sensor for your entire plant even though you have differing distances between your probes and transmitters. ***COMING SOON*** Digital Sensors Expanded Quick Disconnect Cabling Contact Your Local Representative 7

Model Q45P/R. ph/orp Monitor...

Model Q45P/R. ph/orp Monitor... Model Q45P/R ph/orp Monitor... Sensor Mounting Configurations The Differential Difference ORP Monitor ATI's versatile Q45P/R ph/orp system is designed for use in all industrial and municipal applications.

More information

Model Q45P/R. ph/orp Monitor...

Model Q45P/R. ph/orp Monitor... Model Q45P/R ph/orp Monitor... Sensor Mounting Configurations The Differential Difference ORP Monitor ATI's versatile Q45P/R ph/orp system is designed for use in all industrial and municipal applications.

More information

A New Standard of Excellence

A New Standard of Excellence A New Standard of Excellence PREVENTION IS SO EASY... LIVING THROUGH A DISASTER IS NOT The reliable identification of low combustion oxygen in a fired heater or boiler has always been critical to the effectiveness

More information

MXD75 Multi Channel Suspended Solids and Turbidity Transmitter

MXD75 Multi Channel Suspended Solids and Turbidity Transmitter ~ Specialists in process suspended solids & turbidity ~ MXD75 Multi Channel Suspended Solids and Turbidity Transmitter Up to 3 Sensors on one Transmitter. Parameters include Suspended Solids, Turbidity

More information

Improve Performance and Reduce Maintenance Costs. Model Q45D. Dissolved Oxygen Monitor...

Improve Performance and Reduce Maintenance Costs. Model Q45D. Dissolved Oxygen Monitor... Improve Performance and Reduce Maintenance Costs Model Q45D Dissolved Oxygen Monitor... Why Throw Away Money? Why Throw Away Money? ATI s Model Q45D Dissolved Oxygen monitor is designed to provide reliable

More information

AquaLynx 200 ADX. Monitoring and Control System. Background. Operation

AquaLynx 200 ADX. Monitoring and Control System. Background. Operation AquaLynx 200 ADX Monitoring and Control System The RODI Systems AquaLynx 200 ADX is a unique monitoring system for water treatment applications. The AquaLynx 200 ADX offers a dependable yet affordable

More information

Corporate Profile. needs and product demands. CON 08X /03 Rev 0

Corporate Profile. needs and product demands. CON 08X /03 Rev 0 Corporate Profile A leader in the field of electrochemical instrumentation, Eutech Instruments is a dynamic company rapidly positioning itself globally as a leading manufacturer of electrochemical instrumentation

More information

SECTION Fluorescent Dissolved Oxygen Measuring System

SECTION Fluorescent Dissolved Oxygen Measuring System SECTION 40 75 43 Fluorescent Dissolved Oxygen Measuring System PART 1 General 1.01 SUMMARY A. Requirements for a high-performance, digital fluorescence sensor for measurement of dissolved oxygen in liquid.

More information

Concise catalogue Water-Industry

Concise catalogue Water-Industry 2008 Concise catalogue Water-Industry One-channel instruments to measure ph, EC, DO and free chlorine, panel and wall-mounting version. Transmitters - controllers very easy to utilize, the customer does

More information

Inductive Conductivity

Inductive Conductivity Inductive Conductivity THORNTON Leading Pure Water Analytics 7100E Non-Fouling Sensors PEEK or PFA Wetted Parts Excellent Chemical Resistance 0/4 to 20mA Outputs for Conductivity & Tempreature 4 Relays

More information

Industrial Grade Gas Detection Detecting The Difference

Industrial Grade Gas Detection Detecting The Difference detcon inc. Industrial Grade Gas Detection Detecting The Difference PO Box 8067 The Woodlands, TX 77387 888-367-4286 (toll free) 713-559-9200 281-292-2860 (fax) sales@detcon.com Catalog #CB-0409 www.detcon.com

More information

Electronic Flow Switches

Electronic Flow Switches Industries Electronic Flow Switches Petrochemical Refining Oil Production Water Treatment Pharmaceutical Food and Beverage Pulp and Paper Power Production Gas Processing Mining Biotechnology Semiconductor

More information

Dräger X-am 7000 Multi-Gas Detection

Dräger X-am 7000 Multi-Gas Detection Dräger X-am 7000 Multi-Gas Detection Dräger X-am 7000 is the solution for the simultaneous and continuous measurement of up to five gases. It is the ideal companion in a variety of applications where the

More information

SECTION ph/orp Sensors

SECTION ph/orp Sensors SECTION 40 75 13 ph/orp Sensors PART 1 General 1.01 SUMMARY A. Requirements for a ph/orp sensor for in-process measurement. The sensor will incorporate Memosens digital technology for maximum process and

More information

Smart Sensors and Analytical Instruments Honeywell Solutions for Analytical Measurement and Control

Smart Sensors and Analytical Instruments Honeywell Solutions for Analytical Measurement and Control Industrial Measurement and Control Smart Sensors and Analytical Instruments Honeywell Solutions for Analytical Measurement and Control EASY TO INSTALL... EASY TO USE... EASY TO MAINTAIN... EASY TO OWN.

More information

Ronan Model X96S Series Density System

Ronan Model X96S Series Density System Ronan Model X96S Series Density System For more than 27 years Ronan has provided the process control industry with unsurpassed products in the harshest environments. With a philosophy of designing new

More information

DL424/425 DirectLine Sensor Module for Dissolved Oxygen Probes Series DL5000 Specifications

DL424/425 DirectLine Sensor Module for Dissolved Oxygen Probes Series DL5000 Specifications DL424/425 DirectLine Sensor Module for Dissolved Oxygen Probes Series DL5000 Specifications 70-82-03-48 January 2003 Overview The DirectLine DL424/425 Sensor Modules are part of a family of products developed

More information

FLEXIBLE, AFFORDABLE, HIGH SPECIFICATION OXYGEN GAS ANALYSIS DESIGNED FOR DEMANDING HAZARDOUS AREA PROCESS CONTROL APPLICATIONS.

FLEXIBLE, AFFORDABLE, HIGH SPECIFICATION OXYGEN GAS ANALYSIS DESIGNED FOR DEMANDING HAZARDOUS AREA PROCESS CONTROL APPLICATIONS. SERVOTOUGH FLEXIBLE, AFFORDABLE, HIGH SPECIFICATION OXYGEN GAS ANALYSIS DESIGNED FOR DEMANDING HAZARDOUS AREA PROCESS CONTROL APPLICATIONS Flexible Can be used in hazard rated locations including Zone

More information

For the lower wiring costs of a loop-powered instrument, turn to our popular 876 Series transmitters.

For the lower wiring costs of a loop-powered instrument, turn to our popular 876 Series transmitters. Analyze or control the ph, oxidation reduction potential (ORP), conductivity, or resistivity of your process with exceptional echem solutions such as our 875 Series analyzer. For the lower wiring costs

More information

Tough as They Come. Ceramat. Retractable fittings for extreme conditions. With ceramic sealing to the process.

Tough as They Come. Ceramat. Retractable fittings for extreme conditions. With ceramic sealing to the process. The Art of Measuring. Tough as They Come. Ceramat Retractable fittings for extreme conditions. With ceramic sealing to the process. Minimum wear Low operating costs Maximum availability The Solution: Ceramat

More information

Figure 1 DirectLine DL423 Sensor. Description, continued

Figure 1 DirectLine DL423 Sensor. Description, continued DL423 DirectLine Sensor Module for Conductivity Measurement Overview 70-82-03-47 1/03 Page 1 of 8 Specification DirectLine DL423 for Conductivity measurement is a family of sensors released by Honeywell

More information

ROYCE SUSPENDED SOLIDS SYSTEM MODEL 7011A AND SENSORS MODELS 72A, 72P, 73B, 74A, 75A & 76A

ROYCE SUSPENDED SOLIDS SYSTEM MODEL 7011A AND SENSORS MODELS 72A, 72P, 73B, 74A, 75A & 76A SPECIFICATIONS (Revised 1/12/2006) ROYCE SUSPENDED SOLIDS SYSTEM MODEL 7011A AND SENSORS MODELS 72A, 72P, 73B, 74A, 75A & 76A The system shall operate on the principle of light absorption. It shall consist

More information

THE STANDARD OF EXCELLENCE WDG-V SERIES COMBUSTION ANALYZERS

THE STANDARD OF EXCELLENCE WDG-V SERIES COMBUSTION ANALYZERS THE STANDARD OF EXCELLENCE WDG-V SERIES COMBUSTION ANALYZERS A Worldwide Manufacturer of Process Analyzers and Instrumentation RELIABILITY EXPERIENCE SOLUTIONS AMETEK Process Instruments is a worldwide

More information

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Dräger Polytron 8700 IR Detection of flammable gases and vapors Dräger Polytron 8700 IR Detection of flammable gases and vapors The Dräger Polytron 8700 IR is an advanced explosion proof transmitter for the detection of combustible gases in the lower explosion limit

More information

Ronan Model X96S Series Weighing System

Ronan Model X96S Series Weighing System Ronan Model X96S Series Weighing System For more than 27 years Ronan has provided the process control industry with unsurpassed products in the harshest environments. With a philosophy of designing new

More information

Figure 1 DirectLine DL423 Sensor. Description, continued

Figure 1 DirectLine DL423 Sensor. Description, continued DL423 DirectLine Sensor Module for Conductivity Measurement Overview 70-82-03-47 4/02 Page 1 of 8 Specification DirectLine DL423 for Conductivity measurement is a family of sensors released by Honeywell

More information

Slope Zero MEAS CAL ALARM CONF APT2000 PH ENCLOSURE TYPE 2

Slope Zero MEAS CAL ALARM CONF APT2000 PH ENCLOSURE TYPE 2 APT 2000 Series 2-Wire ph Transmitters 70-82-03-32 2/00 Page 1 of 8 Specification Overview The Honeywell Analytical Process Transmitter (APT) 2000 Series transmitter is a two-wire 24-Volt device that continuously

More information

Inductive Conductivity Measurement. Simultaneous display of conductivity/ resistance/salinity and temperature; large measurement symbol.

Inductive Conductivity Measurement. Simultaneous display of conductivity/ resistance/salinity and temperature; large measurement symbol. Process Analysis Systems Chem Energy Pharm Food Water Stratos Eco 2405 CondI Inductive Conductivity Measurement Simultaneous display of conductivity/ resistance/salinity and temperature; large measurement

More information

Model 6650SP. Filber Optic-Based UV-Fluorescence Oil-in-Water Analyzer

Model 6650SP. Filber Optic-Based UV-Fluorescence Oil-in-Water Analyzer Model 6650SP Filber Optic-Based UV-Fluorescence Oil-in-Water Analyzer 6650SP - OVERVIEW The Model 6650SP is the next generation in-water Analyzer. The 6650SP incorporates the most advanced, state-of-the-art

More information

Industrial Grade Gas Detection

Industrial Grade Gas Detection Industrial Grade Gas Detection DETECTING THE... Difference Catalog #CB 0112 detcon inc. an company www.detcon.com Houston Odessa Shanghai Dammam Del Carmen Europe Company Profile ISO 9001: 2008 Certified

More information

Dräger Polytron 7000 Fixed gas detector

Dräger Polytron 7000 Fixed gas detector DETECTION PERSONAL PROTECTION DIVING TECHNOLOGY SYSTEM TECHNOLOGY SERVICES Dräger Polytron 7000 Fixed gas detector ST-3751-2003 The Dräger Polytron 7000 is a gas detector that can satisfy all toxic and

More information

Dräger Polytron 8000 Stationary gas detector (EC)

Dräger Polytron 8000 Stationary gas detector (EC) Dräger Polytron 8000 Stationary gas detector (EC) The microprocessor-based transmitter can be equipped with various electrochemical DrägerSensors. This way, you can easily detect oxygen and various toxic

More information

Effluent Monitoring. Solutions

Effluent Monitoring. Solutions Products Solutions Effluent Monitoring Solutions Avoid Unnecessary Fines Services Effluent Monitoring Solution Overview Our effluent monitoring solution consists of a base package with a redundant ph system.

More information

DL423 DirectLine Sensor Module for Conductivity Measurement Specifications

DL423 DirectLine Sensor Module for Conductivity Measurement Specifications DL423 DirectLine Sensor Module for Conductivity Measurement Specifications 70-82-03-47 January 2003 Overview DirectLine DL423 for Conductivity measurement is a family of sensors released by Honeywell as

More information

ULTIMA X5000. MSAX5000.com

ULTIMA X5000. MSAX5000.com ULTIMA X5000 MSAX5000.com WE KNOW YOU RE TIRED OF... NEEDING TO DISCONNECT POWER BEFORE CHANGING A SENSOR REMEMBERING HOW TO CALIBRATE THIS THING HAVING TO PULL SO MUCH WIRE AT EVERY GAS DETECTOR INSTALLATION...

More information

Series 3300 TELEDYNE ANALYTICAL INSTRUMENTS. The 3300 series of low cost, microprocessorbased

Series 3300 TELEDYNE ANALYTICAL INSTRUMENTS. The 3300 series of low cost, microprocessorbased TELEDYNE Series 3300 Unaffected by hydrocarbons, H2, or CO2 Easy to handle, inexpensive, and easy to replace Can apply to ppb, ppm, and percent ranges Trace & Percent Oxygen Analyzers Fuel Cell Zirconium

More information

Steam and Water Analysers

Steam and Water Analysers Steam and Water Analysers A Comprehensive Range for Steam and Water Analysis System (SWAS) ANALYTICAL INSTRUMENTS Energy Conservation Environment Process Efficiency www.forbesmarshall.com Steam and Water

More information

MultiMeter 44. Transmitter-regulator with 1, 2 or 3 channels. Quality at a reasonable price

MultiMeter 44. Transmitter-regulator with 1, 2 or 3 channels. Quality at a reasonable price MultiMeter 44 Transmitter-regulator with 1, 2 or 3 channels MultiMeter 44 is a modular meter that can be configured with one, two or three channels. It can be delivered with only one measuring channel,

More information

Industrial Grade Gas Detection

Industrial Grade Gas Detection Industrial Grade Gas Detection DETECTING THE... Difference Catalog #CB 0912 detcon inc. an company www.detcon.com Houston Odessa Shanghai Dammam Del Carmen UK Company Profile ISO 9001: 2008 Certified 105-A

More information

SECTION Process and Immersion Turbidity and Total Suspended Solids Sensor

SECTION Process and Immersion Turbidity and Total Suspended Solids Sensor SECTION 40 75 53 Process and Immersion Turbidity and Total Suspended Solids Sensor PART 1 General 1.01 SUMMARY A. Requirements for a digital sensor for process turbidity or Total Suspended Solids (TSS)

More information

Dependable Solutions for Gas Detection

Dependable Solutions for Gas Detection Dependable Solutions for Gas Detection Combustibles/Flammables Standard & Exotic Toxics Oxygen Enrichment/Deficiency Introduction to Sensidyne Established in 1983 - acquired by Schauenburg GmbH in April

More information

SECTION INDUCTIVE CONDUCTIVITY ANALYZERS

SECTION INDUCTIVE CONDUCTIVITY ANALYZERS SECTION 40 75 16 INDUCTIVE CONDUCTIVITY ANALYZERS PART 1 General 1.01 SUMMARY A. Requirements for a digital inductive conductivity sensor for standard, hazardous and hightemperature applications. The sensor

More information

MEAS CAL ALARM CONF APT2000 CC ENCLOSURE TYPE 2

MEAS CAL ALARM CONF APT2000 CC ENCLOSURE TYPE 2 APT2000 Series 2-Wire Contacting Conductivity Transmitters Overview The Honeywell Analytical Process Transmitter (APT) 2000 Series transmitter is a two-wire 24-Volt device that continuously measures conductivity,

More information

Dräger Polytron 8200 CAT Detection of flammable gases and vapors

Dräger Polytron 8200 CAT Detection of flammable gases and vapors Dräger Polytron 8200 CAT Detection of flammable gases and vapors The Dräger Polytron 8200 CAT is an advanced explosion proof transmitter for the detection of flammable gases in the lower explosion limit

More information

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors Ultima X Series Gas Monitors Versatile fixed instruments provide continuous monitoring of many hazardous gases using catalytic, electrochemical, and infrared gas detection methods. HART Protocol is now

More information

PUV, PIR and PFO Series BROCHURE

PUV, PIR and PFO Series BROCHURE PUV, PIR and PFO Series BROCHURE JUNHO 2013 ABB Multiwave TM process photometers PUV3402, PIR3502 and PFO3372 Measure vapor and liquid samples in IR, NIR, UV and VIS regions Process photometers PUV3402,

More information

Turbidity Systems. Inline Turbidity Measurements For More Visibility Into Your Process. INGOLD Leading Process Analytics

Turbidity Systems. Inline Turbidity Measurements For More Visibility Into Your Process. INGOLD Leading Process Analytics INGOLD Leading Process Analytics Turbidity Systems InPro 8000 Sensor Series Trb 8300 Transmitter Series Improved product quality and process reliability Increased productivity Easy handling Enhanced process

More information

Date SECTION MEASUREMENT AND CONTROL INSTRUMENTATION Project Name Page 1

Date SECTION MEASUREMENT AND CONTROL INSTRUMENTATION Project Name Page 1 Project Name Page 1 PART 1 GENERAL 1.1 Section includes: A. A modular single or dual channel controller that works with analog sensor modules and/or digital sensors. 1.2 Measurement Procedures A. Microprocessor-based

More information

PURSense Sanitary Flange Conductivity Sensors

PURSense Sanitary Flange Conductivity Sensors PURSense 403 & 403VP Sensors LIQ-PDS-PURSense-403-403VP-Sensors Product Data Sheet September 2015 PURSense Sanitary Flange Conductivity Sensors Conductivity sensor designed to meet USP requirements in

More information

Technical Information OUSTF10

Technical Information OUSTF10 TI00500C/07/EN/01.13 71157320 Products Solutions Services Technical Information Optical sensor combined with flow assembly OUA260 for measurement of turbidity and non-dissolved solids Application The scattered

More information

Excellence through Versatility

Excellence through Versatility Controllers Excellence through Versatility Located in Acton, Massachusetts, Liquid Metronics has been providing quality products and service to the water treatment industry worldwide for over 20 years.

More information

HIGH CAPACITY PRODUCT LINE

HIGH CAPACITY PRODUCT LINE HIGH CAPACITY PRODUCT LINE Highest Quality, Best Service Manufacturing chlorination equipment and related products since 1978 PROUDLY MADE IN USA 600 Emlen Way, Telford, PA 18969 Telephone: (215) 799-0980

More information

Stratos MS. Internationally recognizable icons provide operating information and draw attention to unusual operating states.

Stratos MS. Internationally recognizable icons provide operating information and draw attention to unusual operating states. MS Stratos MS Digital Memosens Transmitter Multi-Parameter Memosens Transmitter The digital platform. Multi-parameter transmitter With the Stratos MS, Knick is now offering a low-cost, purely digital version

More information

Dräger Polytron 8310 IR Detection of flammable gases and vapour

Dräger Polytron 8310 IR Detection of flammable gases and vapour Dräger Polytron 8310 IR Detection of flammable gases and vapour The Dräger Polytron 8310 IR is an advanced explosion proof transmitter for the detection of combustible gases in the lower explosion limit

More information

Transmitter Series. Intelligent Transmitter Series Tailor the Measurement to Your Needs INGOLD

Transmitter Series. Intelligent Transmitter Series Tailor the Measurement to Your Needs INGOLD INGOLD Leading Process Analytics Transmitter Series M300 / M400 / M700 / M800 Transmitters Reliable Intelligent Diagnostics Versatile and Tailorable Easy Handling Intelligent Transmitter Series Tailor

More information

SECTION Free/Available Chlorine Analysis System

SECTION Free/Available Chlorine Analysis System SECTION 40 75 21 Free/Available Chlorine Analysis System PART 1 General 1.01 SUMMARY A. Requirements for a digital sensor system for free chlorine measurement for disinfection purposes in drinking water,

More information

Process Gas Chromatograph

Process Gas Chromatograph A I T Applied Instrument Technologies FXi Series5 PRODUCT SPECIFICATIONS Process Gas Chromatograph PSS FXI-S5 The FXi Series5 Process Gas Chromatograph (PGC) continuously analyzes, measures, and reports

More information

Dräger Polytron 8720 IR Detection of carbon dioxide

Dräger Polytron 8720 IR Detection of carbon dioxide Dräger Polytron 8720 IR Detection of carbon dioxide The Dräger Polytron 8720 IR is an advanced explosion proof transmitter for the detection of carbon dioxide in percent volume or ppm It uses a high performance

More information

HIGH CAPACITY PRODUCT LINE

HIGH CAPACITY PRODUCT LINE HIGH CAPACITY PRODUCT LINE Highest Quality, Best Service Manufacturing chlorination equipment and related products since 1978 PROUDLY MADE IN USA 600 Emlen Way, Telford, PA 18969 Telephone: (215) 799-0980

More information

SIL 2. Ultima X Series Gas Monitors CERTIFIED

SIL 2. Ultima X Series Gas Monitors CERTIFIED Ultima X Series Gas Monitors 5 Now with SIL 2 CERTIFIED Products Versatile fixed instruments provide continuous monitoring of many hazardous gases using catalytic, electrochemical, and infrared gas detection

More information

Model D12-IR. Digital Gas Transmitter...

Model D12-IR. Digital Gas Transmitter... Model D12-IR Digital Gas Transmitter... ATI s Series D12 gas transmitter line now includes a versatile Infrared system that can be configured for LEL or select toxic gases. The D12-IR utilizes a compact

More information

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Dräger Polytron 8700 IR Detection of flammable gases and vapors Dräger Polytron 8700 IR Detection of flammable gases and vapors The Dräger Polytron 8700 IR is an advanced explosion proof transmitter for the detection of combustible gases in the lower explosion limit

More information

Dräger Polytron 5700 IR Detection of flammable gases and vapours

Dräger Polytron 5700 IR Detection of flammable gases and vapours Dräger Polytron 5700 IR Detection of flammable gases and vapours The Dräger Polytron 5700 IR is a cost effective explosion-proof transmitter for the detection of flammable gases in the lower explosive

More information

MSM400 Ultrasonic Suspended Solids Monitoring and Control System

MSM400 Ultrasonic Suspended Solids Monitoring and Control System Product Data Sheet MSM400 Ultrasonic Suspended Solids Monitoring and Control System Continuous sludge discharge monitor for up to 50% suspended solid The MSM400 system contains a control unit and either

More information

MEAS CAL ALARM WASH CONF APT4000 PH ENCLOSURE TYPE 2. Description

MEAS CAL ALARM WASH CONF APT4000 PH ENCLOSURE TYPE 2. Description APT4000 Series 4-Wire ph Analyzers 70-82-03-44 10/03 Page 1 of 8 Specification Overview The Honeywell Analytical Process Analyzer (APT) 4000 Series 2 continuously measures ph or ORP in industrial processes

More information

Dräger PIR 7200 Toxic Gas Detection Transmitter

Dräger PIR 7200 Toxic Gas Detection Transmitter Dräger PIR 7200 Toxic Gas Detection Transmitter ST-11660-2007 When you are looking for a carbon dioxide monitor you can trust, consider the Drager PIR 7200. This explosion-proof point gas detection transmitter

More information

OPERATION MANUAL. THE JENCO MODEL 6230 MICROCOMPUTER BASED ph/mv/temp PORTABLE METER JENCO ELECTRONICS, LTD. MANUFACTURER OF PRECISION INSTRUMENTS

OPERATION MANUAL. THE JENCO MODEL 6230 MICROCOMPUTER BASED ph/mv/temp PORTABLE METER JENCO ELECTRONICS, LTD. MANUFACTURER OF PRECISION INSTRUMENTS OPERATION MANUAL THE JENCO MODEL 6230 MICROCOMPUTER BASED ph/mv/temp PORTABLE METER JENCO ELECTRONICS, LTD. MANUFACTURER OF PRECISION INSTRUMENTS GENERAL INTRODUCTION The model 6230 is a precise instrument

More information

Hydrazine Analyzer Series 2171 Specifications

Hydrazine Analyzer Series 2171 Specifications Hydrazine Analyzer Series 2171 Specifications 70-82-03-64 November 2009 Introduction The 2171 is the most advanced hydrazine instrument specifically developed for use in continuous measurement and determination

More information

OPTISENS TUR 2000 Technical Datasheet

OPTISENS TUR 2000 Technical Datasheet OPTISENS TUR 2000 Technical Datasheet Sensor for turbidity measurement in water and wastewater Rugged design for harsh applications Integrated transmitter with direct 4...20 ma output Near infrared light

More information

High Pressure Conductivity Monitor

High Pressure Conductivity Monitor Product Data Sheet PDS 71-EDS880/1/rev.A August 2006 Model EDS880/1 High Pressure Conductivity Monitor COMPLETE SYSTEM FOR THE DETERMINATION OF CONDUCTIVITY IN HIGH PRESSURE SYSTEMS SENSOR INSTALLS DIRECTLY

More information

S5000 Gas Monitor. GMS5000.com

S5000 Gas Monitor. GMS5000.com S5000 Gas Monitor GMS5000.com A DETECTOR AS TOUGH AS YOU ARE... LOWER TEMPERATURE SPEC?... ARCTIC WINTERS IT HAS TO BE THE MOST RELIABLE PIECE OF EQUIPMENT OUT HERE IF THE DETECTOR DOESN T WORK, WE DON

More information

Toxic Gas Detection. Model F12. Toxic Gas Detection

Toxic Gas Detection. Model F12. Toxic Gas Detection Toxic Gas Detection Model F12 Toxic Gas Detection Smart Sensor Technology The Series F12 Gas Transmitter is an Intrinsically Safe (IS) version of our explosion-proof D12 transmitter. In its standard form,

More information

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors Dräger Polytron 5700 Fixed Gas Detector Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors Dräger Polytron 5700 Including e-box for increased safety wiring The Dräger

More information

Durafet II and Meredian II Combination ph/orp Electrodes for Honeywell 7777 Mountings Series 7777 Specifications

Durafet II and Meredian II Combination ph/orp Electrodes for Honeywell 7777 Mountings Series 7777 Specifications Durafet II and Meredian II Combination ph/orp Electrodes for Honeywell 7777 Mountings Series 7777 Specifications 70-82-03-06 July 2004 Overview Honeywell s 7777 Series of electrode mountings enables an

More information

SCM. Micro. Streaming Current Monitor. Analyzer. Sensor/Sampler with light shield removed. The Analyzer. Instrument Overview

SCM. Micro. Streaming Current Monitor. Analyzer. Sensor/Sampler with light shield removed. The Analyzer. Instrument Overview Micro SCM Streaming Current Monitor A Watts Water Technologies Company Instrument Overview The instrument consists of the Analyzer and the SCM sensor. Analyzer The Analyzer The monitor has a built in graphic

More information

SPECIFICATIONS - DETAILED PROVISIONS Section Magnetic Flowmeters C O N T E N T S

SPECIFICATIONS - DETAILED PROVISIONS Section Magnetic Flowmeters C O N T E N T S Revised 04/13/16 SPECIFICATIONS - DETAILED PROVISIONS Section 17210 - Magnetic Flowmeters C O N T E N T S PART 1 - GENERAL... 1 1.01 GENERAL REQUIREMENTS... 1 1.02 PROJECT SPECIFIC REQUIREMENTS... 1 1.03

More information

PRODUCT LINE. Highest Quality, Best Service

PRODUCT LINE. Highest Quality, Best Service PRODUCT LINE Highest Quality, Best Service Manufacturing chlorination equipment and related products since 1978 PROUDLY MADE IN USA 600 Emlen Way, Telford, PA 18969 Telephone: (215) 799-0980 Fax: (215)

More information

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Dräger Polytron 5100 EC Detection of toxic gases and vapors Dräger Polytron 5100 EC Detection of toxic gases and vapors The Dräger Polytron 5100 EC is a cost-effective explosion proof transmitter for the detection of toxic gases or oxygen. It uses a high performance

More information

MEAS CAL ALARM WASH CONF APT4000 PH ENCLOSURE TYPE 2. Description

MEAS CAL ALARM WASH CONF APT4000 PH ENCLOSURE TYPE 2. Description APT4000 Series 4-Wire ph Transmitters 3/01 Page 1 of 8 Specification Overview The Honeywell Analytical Process Transmitter (APT) 4000 Series transmitter continuously measures ph or ORP in industrial processes

More information

4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head

4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head 4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head NET DRAFT version 2.1-2008 Pag. 1 4-20mA Cyber - DRAFT version 2.1-2008 Pag.

More information

Condumax CLS16 and CLS16D

Condumax CLS16 and CLS16D Technical Information Condumax CLS16 and CLS16D Hygienic conductivity sensor, analog or digital with Memosens technology, cell constant k = 0.1 cm -1 Application Measurement in pure and ultrapure water:

More information

Dräger Polytron Pulsar 2 Open Path Gas Detector

Dräger Polytron Pulsar 2 Open Path Gas Detector Dräger Polytron Pulsar 2 Open Path Gas Detector The Dräger Polytron Pulsar 2 represents the latest infrared technology in open path gas detection. Equipped with all the same functions as the standard Dräger

More information

MEAS CAL ALARM WASH CONF APT4000 CC ENCLOSURE TYPE 2

MEAS CAL ALARM WASH CONF APT4000 CC ENCLOSURE TYPE 2 APT4000 Series 4-Wire Contacting Conductivity Analyzers Overview 70-82-03-45 10/03 Page 1 of 8 Specification The Honeywell Analytical Process Analyzer (APT) 4000 Series2 continuously measures conductivity,

More information

MEAS CAL ALARM WASH CONF APT4000 TC

MEAS CAL ALARM WASH CONF APT4000 TC APT4000 Series Toroidal Conductivity Transmitters Overview 70-82-03-42 3/01 Page 1 of 8 Specification The Honeywell Analytical Process Transmitter (APT) 4000 Series transmitter continuously measures conductivity,

More information

All icon products are. Easy to use: with an intuitive glass touch-screen, wipe-clean graphic user interface with multi-language options.

All icon products are. Easy to use: with an intuitive glass touch-screen, wipe-clean graphic user interface with multi-language options. All icon products are Easy to use: with an intuitive glass touch-screen, wipe-clean graphic user interface with multi-language options. Certified to global standards: ATEX, IECEx, TIIS, EAC-EX, ETL approved

More information

P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification

P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification 1.0 This specification details the attributes and operating characteristics of the MSA Ultima X Series sensors/transmitters.

More information

Dräger Polytron 5720 IR Toxic Gas Detection

Dräger Polytron 5720 IR Toxic Gas Detection Dräger Polytron 5720 IR Toxic Gas Detection The Dräger Polytron 5720 IR is a cost-effective explosion proof transmitter for the detection of carbon dioxide in volume percentage or ppm It uses a high-performance

More information

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Dräger Polytron 5200 CAT Detection of flammable gases and vapours Dräger Polytron 5200 CAT Detection of flammable gases and vapours The Dräger Polytron 5200 CAT is a cost-effective explosion-proof transmitter for the detection of flammable gases in the lower explosion

More information

Model 1000 H 2 S E-Chem/ CO 2 Process Analyzer

Model 1000 H 2 S E-Chem/ CO 2 Process Analyzer 24VDC OUT 2.1A 18-36 VDC IN Model 1000 H 2 S E-Chem/ CO 2 Process Analyzer + + SAMPLE FLOW AIR FLOW SAMPLE FLOW Operator s Installation and Instruction Manual Detcon Model 1000 H 2 S/CO 2 Analyzer consists

More information

Inductive. Range. S410/IND Electrodeless Conductivity Sensors

Inductive. Range. S410/IND Electrodeless Conductivity Sensors Inductive Range Inductive 0 1.000 μs; 0 10.000 μs; 0 100.000 μs; 0 1 Simens (0 999,999mS) Resolution 1 μs; 10 μs; 100 μs; 1.000 μs S410/IND Electrodeless Conductivity Sensors Low Cost Low Maintenance Online,

More information

SEC Signature Process Gas Analyzer

SEC Signature Process Gas Analyzer SEC Signature Process Gas Analyzer Instruction and Operation Manual Sensor Electronics Corporation 5500 Lincoln Drive Minneapolis, Minnesota 55436 USA (952) 938-9486 Fax (952) 938-9617 email sensor@minn.net

More information

Table of Contents 1. OVERVIEW SYSTEM LAYOUT SPECIFICATIONS FUNCTION... 11

Table of Contents 1. OVERVIEW SYSTEM LAYOUT SPECIFICATIONS FUNCTION... 11 Table of Contents 1. OVERVIEW... 3 2. SYSTEM LAYOUT... 4 3. SPECIFICATIONS... 8 3.1 SYSTEM COMPONENTS...9 3.2 PLC INPUTS AND OUTPUTS...9 3.3 FUNCTION KEYS...10 3.4 DEFAULT SET POINTS AND TIMERS...10 4.

More information

In-line Oil in Water Analyser - Model OIW-EX100P and OIW-EX1000P

In-line Oil in Water Analyser - Model OIW-EX100P and OIW-EX1000P brochure In-line Oil in Water Analyser - Model OIW-EX100P and OIW-EX1000P Advanced Sensors Ltd Oil in Water Analyser System known as the OIW-EX100P or OIW-EX 1000P. The system is designed to monitor the

More information

Temperature Solutions Line Card

Temperature Solutions Line Card Solutions September 2015 We re Your One Stop Temp Shop One simple model number is all it takes to order our complete, Ready-to-Install Assemblies. They include your choice of: Universal PC-Programmable,

More information

OMA-300 Process Analyzer

OMA-300 Process Analyzer A window into your process since 1994. The OMA Process Analyzer continuously measures chemical concentrations and physical properties that can be correlated from the 200-1100 nm (UV-Vis / SW-NIR) absorbance

More information

Dissolved Oxygen Measurement liquisys M COM 223 / 253

Dissolved Oxygen Measurement liquisys M COM 223 / 253 Technical Information TI 199C/24/ae Dissolved Oxygen Measurement liquisys M COM 223 / 253 Oxygen Controller Benefits at a glance Liquisys M COM 223 Liquisys M COM 253 Due to the modularity of its design,

More information

Dräger Polytron 8100 EC Detection of toxic gases and oxygen

Dräger Polytron 8100 EC Detection of toxic gases and oxygen Dräger Polytron 8100 EC Detection of toxic gases and oxygen The Polytron 8100 EC is Dräger s top of the line explosion-proof transmitter for the detection of toxic gases or oxygen It uses a high performance

More information

APPLIED. OMA-300 Hydrogen Sulfide Analyzer H 2. Ex p. Ex d. The world s safest continuous H 2. S analyzer. The OMA continuously measures H 2

APPLIED. OMA-300 Hydrogen Sulfide Analyzer H 2. Ex p. Ex d. The world s safest continuous H 2. S analyzer. The OMA continuously measures H 2 H 2 S Ex p Ex d The world s safest continuous H 2 S analyzer. The OMA continuously measures H 2 S concentration using a full-spectrum UV-Vis spectrophotometer, harvesting the power of collateral data to

More information

Model 144H. Product Data Sheet , Rev DB February Content

Model 144H. Product Data Sheet , Rev DB February Content Rosemount 144 PC-Programmable Temperature Transmitter Provides an installation-ready solution for temperature monitoring applications using Complete Point Solutions (CPS) Increases measurement accuracy

More information

Electronic Pressure Digest. Pressure and Temperature Transmitters

Electronic Pressure Digest. Pressure and Temperature Transmitters Electronic Pressure Digest Electronic Pressure Digest Pressure and Temperature Transmitters R General Purpose Pressure Transmitters Standard Industrial S-10 These rugged pressure transmitters are designed

More information