RAIN GUTTERS COMPLETE RANGE OF PLASTIC RAIN GUTTERS PLASTMO.DK

Size: px
Start display at page:

Download "RAIN GUTTERS COMPLETE RANGE OF PLASTIC RAIN GUTTERS PLASTMO.DK"

Transcription

1 RAIN GUTTERS COMPLETE RANGE OF PLASTIC RAIN GUTTERS PLASTMO.DK

2 ABOUT PLASTMO We are a Danish company that was founded in 198. Today our headquarters and manufacturing facility is in Ringsted. We are the market leader in Denmark for solutions to handle rain water, such as rain gutters, drainage, gabions and lightweight roofing solutions. The company is part of the Plas Nordic division that operates in Denmark, Norway, Sweden, Finland and Poland with an annual turnover of approximately DKK 20 million and 100 employees. Plas A/S is owned by the international ACO group, which has an annual turnover of DKK,3 billion, and is the world leader in line drainage. 2

3 Scandinavian design and quality QUALITY Plas has produced rain gutters for the Nordic climate for more than 0 years. The result is a complete range of durable and simple solutions that provide you with some unique benefits. Regardless of whether you are building new construction or renovating. TIGHT JOINS AND SIMPLE ASSEMBLY WITH GLUE All parts in our rain gutter system are bonded together to get unobtrusive and tight joins. After five decades spent with home owners in the Nordic countries, the glue has demonstrated its strength, and is still holding up. You can use glue for all materials. At the same time it is simple and quick to install the rain gutters and it provides you with extra security that you will achieve a good result. 3

4 PLASTMO PLASTIC RAIN GUTTERS Plas Plastic Rain Gutters have proven their strength for more than half a century. Plastic is not affected by airborne pollution and salty air in coastal areas. They are strong and stable and will last for many years to come. CHOSE BETWEEN SEVERAL COLORS White Gray Graphite Brown Black 4

5 THE ENVIRONMENT Plas Plastic Rain Gutters do not contain any plasticizers or heavy metals that are harmful to the environment. A PIECE OF GOOD ADVICE Place one side of your ladder against a gutter bracket when you install or clean a rain gutter for fallen leaves. This prevents damage to the plastic rain gutter that over the years might have become less flexible. FACTS MATERIAL Plastic rain gutters are manufactured from reusable unleaded hard polyvinyl chloride that does not contain any form of plasticizers. Plastic does not corrode or rust, and will not combine with other materials. Plastic can therefore be used for all types of roofing. The special Plas glue combines with the plastic rain gutter so that the glued join becomes extra strong and stable. WEATHER AND CLIMATE Plastic can withstand extremely low temperatures and severe stress from ice and snow without the risk of freeze cracks. Plastic is also not affected by airborne pollution or salty air. You can therefore use plastic, regardless of where you live. RANGE Rain Gutters are available in sizes 10, 11 and 12. Downspouts are available in diameters of 7, 90 and 110 mm. See our complete range listed in the table in the back of this booklet. In addition you can order virtually any design you may desire as special plastic fittings parts. SUPPLY AND STORAGE Rain gutters and pipes are usually delivered with a strapex-tape, which you must remove as soon as possible. Never store packaged rain gutters and pipes in direct sunlight. WARRANTY We provide a 2-year guarantee on plastic rain gutters. You are covered against manufacturing and material defects that cause leakage. The warranty does not cover any form of consequential damage such as operating damage.

6 as as as Sverige T Sverige T Sverige T as as Tl f T Norge Sverige Tl f T Norge Sverige as Tl f T Norge Sverige as Tl f T Norge Sverige RANGE OUR STANDARD PROGRAM COVERS MOST NEEDS Product Illustration Comments 1 Rain gutter Available in lengths of 3 and 6 m. 2 Connector To join rain gutters. Remember connectors for corners if necessary. 3 Spout Transitions between rain gutters and downspouts. Remember a downspout connector sleeve if necessary. 4 Expansion spout End plate 7A Steel Plus Remember a downspout Size connector Colli sleeve if necessary Fits both ends of the rain gutter x Exterior corner 90 Interior corner 90 Plastic mounting bracket Triangle wedge 18 and 27 With integrated Sizeconnector With integrated connector Used with vertical Size fascia board. Distribute Colli with max. 600 mm spacing Used with slanted fascia board or roof lath Steel Plus Metal mounting bracket Used with vertical Size 7A fascia board or roof Colli lath Metal mounting bracket 20 Used with slanted fascia board or roof lath Steel Plus Metal mounting bracket 27 Used with slanted Size 7A fascia board or roof Colli lath Metal rain gutter bracket short Shaft length 190 mm Steel Plus Size Metal rain gutter bracket long 7A Shaft length 31 mm a Screws Mounting screws for metal mounting brackets and metal rain gutter brackets Steel Plus Size Colli Downspouts 7A Available in lengths of 3 m. Remember a downspout connector sleeve if necessary Elbow 19 Downspout connector sleeve 7A 7A Norge Tl f Steel Plus Steel Plus Norge Tl f Colli Colli x x x x x x 10 2 elbows are always used. Remember to calculate a little extra downspout to insert between the elbows. 12 With 90 sleeve and tip Used for joining downspouts and where the downspout is mounted directly on the spout Junction Used for shared downflow from multiple systems. Norge Tl f

7 as Sverige T as Tl f T Norge Sverige as Product Illustration Comments 21 Down conductor Used as transition from downspouts to the sewer. 22 Expeller Used where the downspout is not connected to the sewer. 23 Well collar 10 mm. diameter For cement sewage pipes. 24 Well collar 130 mm. diameter For PVC sewage pipe sleeve. 2 Clamp for plastic pipe Screws into the masonry/wall. 2 per pack. Norge Tl f Hinge-pin for wall Hammers into the wall. Galvanised. To be fitted with a spacing of approximately 2 m. 27 Hinge-pin for wood Screws into the masonry/wall. Galvanised or copper. To be fitted with a spacing of approximately 2 m. 28 Rain gutter glue 10 ml Used for plastic rain gutters. 29 Metal rain gutter bracket bender For adapting metal rain gutter brackets to the slope of the roof. 32 Interior and exterior corner 4 For all materials and sizes, 2 connector pieces are used per corner. 33 Adjustable spout Tl f T Norge Sverige Transitions between rain gutters and downspouts. Is bonded at an angle as required (0 7 ). Expansion piece without flow See application in the table. See application in the table. a Expansion piece with flow See application in the table. 3 Foliage collector For mounting in the spout. 36 Water outlet w. flexible hose For connecting to a barrel. Used for collecting rain water. 7 mm. 37 Water exhaust w. flap Used for collecting rain water. 38 Foliage collector w. pipe connection 39 Base edge C Base edge C 12 Is mounted directly on the 110 mm pipe. Can be adapted to 7 and 90 mm pipes by using a pipe connection. Creates the transition between the eaves and the rain gutter. Available in lengths of 2 m in grey, white and graphite. Fits all roof boarding and rain gutter materials. Creates the transition between the eaves and the rain gutter. Available in lengths of 2 m in grey, white and graphite. Fits all roof boarding and rain gutter materials. 44 Adjustable bracket For mounting bracket in size 10, 11 and 12. 7

8 RANGE OUR STANDARD PROGRAM COVERS MOST NEEDS

9 SYSTEM FIND THE RIGHT SYSTEM System sizes are adapted to different types of houses. A size 10 rain gutter is mounted on small buildings such as summer houses and roofing over terraces and conservatories. A size 11 is used for traditional houses and size 12 is mounted on large buildings, such as tenements as well as warehouses and industrial premises. In order to ensure that you have sufficient drainage capacity, you should use the following calculations as your starting point. Check the drainage capacity In the table you can gauge the system s drainage capacity in relation to the location of the downspout. If the drainage area is greater than the figures in the table, you can choose to install an additional downspout, since that increases drainage capacity. Make sure you plan drainage for all downspouts. H B Measurement Table for Rain Gutters Size Width Height Rain Gutters Pipes Location A Drainage Area Rain Gutters Downspouts Drainage area (m 2 ) Drainage area (m 2 ) B Ø7 Ø90 Ø110 Location A Location B Location C Location B Location C A Planning of your system First calculate the roof area (drainage area: A X B), and determine the location of the downspout. The above is calculated on the basis of expected rainfall intensity of 0,0146 l/s/m 2. The rain gutter sizes in the above examples can be combined with the following variable dimensions of the downspouts: Pipe sizes Rain gutter size Plastic grey, white, graphite, brown, black Ø7 Ø90 Ø Is there a need for an expansion spout/expansion piece? Plastic will move slightly when the temperature varies. One should therefore in the following cases use an expansion spout and/or an expansion piece: Plastic rain gutters more than 18 meters in length Plastic rain gutters all the way around the house Expansion Spout If the rain gutter is more than 18 m, expansion spouts should always be installed at all downflows. If there is a rain gutter all the way around the building, expansion spouts are always installed at all downflows. Expansion piece without flow Expansion piece with flow If the distance between downflows is more than 18 m, always install an expansion piece between the downflows. If the distance between downflows is more than 8 m between two miter joints, always install an expansion piece between the corners. 9

10 INSTALLATION INSTRUCTIONS FOR RAIN GUTTERS Master tips Calculation of the roof area When the roof area/drainage area is calculated, it is usually simple to measure the length of the house (A). It can be a little more difficult to measure the distance from the eaves to the ridge (B), but it can be done in the following way: Measure the length of the visible part of one of the lower roofing tiles or plates. Then count how many roofing tiles/plates there are from the eaves to the ridge. Multiply this number with the length of the roofing tiles/ roofing plates so that you have the B-measurement that you will use to calculate the drainage area without having to go up on the roof. Rain gutters with drop If you want the rain gutter to drop, you can arrange the metal gutter brackets next to each other and draw the drop with a marker. If there more than one downflow, the drop is subdivided up so that the drop is equal to both downflows. It is a good idea to number the metal gutter brackets in a place where it is not visible later. Then you can be sure you will mount them correctly the first time. Shortening of rain gutters and pipes Plastic gutters are shortened with a hacksaw or a fine-toothed saw. If you have the option, use the shortened ends at the joins so that right angle ends are used at the end plates. When gutters are sawed through, a loose connector piece can be attached as a cutting template. Storage of rain gutter glue If the glue is very cold, it can be difficult to press out of the tube/cartridge, so store it in a warm place before use. If the glue is not fully used up, you can put a screw into the opening so that it does not dry out Cleaning glue surfaces Wipe the glue surfaces with a dry cloth. Installation of end plates The rain gutter must be able to give a little when it is clicked in to the metal gutter brackets. The end plates stabilize the rain gutter. That is why the rain gutter is more flexible without end plates. So it is usually easier to install the end plates after you have inserted the rain gutter in the metal gutter brackets. Installation of spouts It is a good idea to install the spout when you have cut the hole and before you insert the rain gutter in the metal gutter brackets especially if space is tight. Holders for plastic pipes in brick walls Holders for plastic pipes may not be installed in the mortar joints between bricks. The best and most durable result will be obtained if they are installed in the brick itself to ensure that they always provide proper support and keep the downspout in place. Follow the installation instructions on the pipe holder package so it is possible for the pipe to expand. Paint If you have exterior plastic rain gutters, and you want them to clash as little as possible with their surroundings, the fascia board may be painted in the same colour as the rain gutter itself. The colour codes are specified below that provide a result that is as close as possible to the colour of the rain gutters, which your local supplier must use when mixing the paint. Black: NCS 802-B White: NCS 002-Y Grey: NCS 300 Graphite: NCS 702-B Brown: NCS 8010-Y70R Installation instructions Plas Plastic Gutters

11 INSTALLATION INSTRUCTIONS FOR PVC RAIN GUTTERS YOU NEED A carpenter s rule Plas screws for mounting brackets or metal gutter brackets String A hacksaw or a fine-toothed saw A marker A metal gutter bracket bender (only when metal gutter brackets are used) A screwdriver or screwing machine Click system with glued joining: A dry cloth when mounting plastic gutters Plas Rain Gutter Glue for plastic REMEMBER: Plastic Rain Gutters: Before gluing, all items must be wiped with a dry cloth. New metal rain gutter brackets Rain gutters can be installed horizontally or with a slight drop towards the downspouts (approximately 2mm per linear meter). A drop can be created by drawing the bend marks slightly slanted (see picture). Make a bend mark min. 10 mm from the back hooks. Number the metal rain gutter brackets. New mounting brackets Mounting brackets in plastic or steel Bend the metal rain gutter brackets with a Plas Metal Rain Gutter Bracket Bender. The metal rain gutter brackets are bent at an angle so that the leading edge of the gutter, after installation on the roof is approximately 2 mm lower than the trailing edge. Plastic mounting brackets with a triangular wedge The two outermost metal rain gutter brackets are mounted approximately 10 mm from the barge board or approximately 20 mm from the corner. Stretch-mount a string on the leading edge of the metal rain gutter brackets. Distribute the remaining metal rain gutter brackets with a max. spacing of 600 mm. Take the location of the downspout into account. Mount the metal rain gutter brackets in accordance with the string and attach them with Plas Screws or the largest available galvanised nails (/40). The two outermost mounting brackets are mounted approximately 10 mm from the barge board or approximately 20 mm from the corner. Install horizontally or with drop (approximately 2 mm/m) towards the downspouts. Stretch-mount a string on the leading edge of the mounting brackets. Distribute the remaining mounting brackets with a max. spacing of 600 mm. Fasten with Plas Screws. The two outermost triangular wedges are mounted approximately 10 mm from the barge board or approximately 20 mm from the corner. Install horizontally or with drop (approximately 2 mm/m) towards the downspouts. Stretch-mount a string at the bottom of the wedges. Distribute the remaining wedges with a max. spacing of 600 mm. Then install the mounting brackets.

12 INSTALLATION INSTRUCTIONS FOR PVC RAIN GUTTERS Installation of the rain gutter End plate When installing the rain gutter there should 1 be approximately 2 mm between the end plate and the barge board. However, only a mm gap when mounting on hot days as the rain gutter expands at high temperatures. 2 Apply Plas Rain Gutter Glue to the end plate in an approximately mm wide line. When the rain gutter has been mounted, 3 attach the end plate onto the trailing edge of the rain gutter and rotate upwards so that it meshes with the leading edge of the rain gutter. Spout Place the spout loosely on the rain gutter 4 where the downspout must be. Draw the diameter of the hole for the spout with a marker. Saw with a fine-toothed saw or hacksaw, 2 diagonal cuts against each other. Apply 4 lines of glue in mm width. 6 Apply the two outer lines approximately 1 mm from the edge. Between these, apply two lines of glue on either side of the hole. Install the spout immediately. Connecting piece Attach the spout immediately to the trailing 7 edge of the rain gutter and rotate so that it meshes with the ridge of the rain gutter. Plastic gutters move due to temperature 8 influences. The distance between the connecting piece and the metal rain gutter bracket must be min. 90 mm. When two gutters are to be joined, they must 9 be fitted tightly together. Apply 4 lines of glue in mm width to the connecting piece. Apply the two outer lines approximately 1 mm from the edges. Install immediately. Miter joints Attach the connecting pieces to the trailing edge 10 of the rain gutter. Make sure that the connecting piece is securely attached to the trailing edge of both rain gutters. Then rotate the connecting piece upwards so that it meshes with the ridge of the rain gutter. 11 Apply 2 lines of glue in a width of mm. to one half of the miter joint Install immediately. Attach the miter joint onto the trailing edge 12 of the rain gutter and turn it upwards so that it meshes with the ridge of the rain gutter. Then apply glue to the second half of the miter joint. Then install the second rain gutter in the miter joint.

13 INSTALLATION INSTRUCTIONS FOR PVC RAIN GUTTERS Expansion spout Locking strip Expansion piece Install a metal rain gutter bracket on either 13 side of the expansion spout. Insert the rain gutters into the expansion spout up to the temperature label corresponding to the actual temperature at the time of installation. In case of a vertical fascia board, attach the spout directly onto the fascia without metal rain gutter brackets. A locking strip is fitted between two expansion spouts. Mounting instructions are in- 14 cluded. Attach the locking strip with glue. See application in the table. 1 1A Mounting instructions are included. 1: Without flow 1A: With flow Downspouts Pipe clamps/hinge pins Downspout connector sleeve min. 20 mm Install the first elbow on the spout and 16 measure the length of the pipe to the next elbow (min. 60 mm). In case of an overhang (exceeding 600 mm) glue the upper elbow onto the spout. Install the elbows so that there is a downstream flow. Install the uppermost pipe clamp just below 17 the elbow on the downspout. The uppermost ferrule is mounted so that it clamps around the pipe. The lowermost ferrule is mounted so that it does not clamp around the pipe - this allows the pipe to expand. To be fitted with a spacing of approximately 2 m. When two lengths of pipe must be connected, a downspout connector sleeve is used. 18 Maintain min. 20 mm of air at the bottom of the downspout sleeve. Install a pipe clamp/hinge pin close beneath the downspout connector sleeve. Discharge spout Branch pipe Downlead with well collar Where there is no sewage, a discharge 19 spout is used instead. Glue onto the downspout. When two downpipes must be connected 20 and continued in a downspout, a branch pipe is used. The downspout is inserted100 mm into the 21 downlead, which is then installed in the well collar. Strong joins with Plas rain gutter glue To join Plas Plastic Rain Gutters, a special rain gutter glue is used that makes the glued join strong and stable. Curing time depends on the temperature and can vary from 2 to 24 hours. The rain gutter glue can be used in humid weather and in sightly frosty weather down to - C. In this case a slightly longer curing time must be factored in. A tube with 10 ml rain gutter glue is sufficient for joining approximately 36 meters of rain gutter system.

14 NOTES

15 NOTES

16 DER FALDER MERE OG MERE NEDBØR PLASTMO RAIN GUTTERS IN SCANDINAVIAN QUALITY AND DESIGN Vnr.: aug17 Plas A/S Odinsvej 9-11 DK-4100 Ringsted CVR-nr.: info@plas.dk T: PLASTMO.DK

Gardian W51. Approvals

Gardian W51. Approvals Gardian W51 120 V pre-assembled electric heating cables for pipe freeze protection and roof & gutter de-icing Installation Instructions Description Gardian W51 120 V pre-assembled self-regulating heating

More information

Your roof is waiting for it PRODUCT CATALOGUE Podsufitki

Your roof is waiting for it PRODUCT CATALOGUE Podsufitki www.pdprofil.pl Your roof is waiting for it PRODUCT CATALOGUE Podsufitki The Assa gutter system is a complete system for draining rainwater from the roof, it is designed for new and renovated buildings,

More information

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Outdoor Unit UQB09JJWC UQB12JJWC. Indoor Unit AQB09JJWC AQB12JJWC

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Outdoor Unit UQB09JJWC UQB12JJWC. Indoor Unit AQB09JJWC AQB12JJWC AQB09JJ6WC_IM_E_2585 2006.4.17 4:26 PM Page 17 INSTALLATION MANUAL Indoor Unit AQB09JJWC AQB12JJWC Outdoor Unit UQB09JJWC UQB12JJWC ENGLISH FRANÇAIS ESPAÑOL Split-type Air Conditioner (Cooling and Heating)

More information

INSTALLATION MANUAL SPLIT TYPE ROOM AIR CONDITIONER (PART NO )

INSTALLATION MANUAL SPLIT TYPE ROOM AIR CONDITIONER (PART NO ) SPLIT TYPE ROOM AIR CONDITIONER INSTALLATION MANUAL (PART NO. 9312791019-01) This air conditioner uses new refrigerant HFC (R410A). The basic installation work procedures are the same as conventional refrigerant

More information

Single Wall Flue system. Installation manual WARNING. Installation Manual CoxDENS PPs MC-CG-105 EN_892054

Single Wall Flue system. Installation manual WARNING. Installation Manual CoxDENS PPs MC-CG-105 EN_892054 MC-CG-105 EN_892054 WARNING Installation Manual CoxDENS PPs Incorrect installation of Flue System and Components, or failure to follow installation instructions, can result in property damage or serious

More information

Making Crimp Connections

Making Crimp Connections Making Crimp Connections Cut tube off square (90 ) with a tube cutter. Tube Cutter Slide the PEX crimp ring over the end end of the tube. BE SURE the crimp ring is centered over the PEX barb. Slide the

More information

LINE SET DUCT AND ACCESSORY PRODUCT CATALOG

LINE SET DUCT AND ACCESSORY PRODUCT CATALOG VAC LINE SET DUCT AND ACCESSORY PRODUCT CATALOG Correctly installing an air conditioner requires the use of dedicated accessories. When the customer invests in an air conditioner, he relies on the professional

More information

INSTALLATION INSTRUCTIONS. Aluminum Blinds - Standard - - Lift & Lock -

INSTALLATION INSTRUCTIONS. Aluminum Blinds - Standard - - Lift & Lock - 1 INSTALLATION INSTRUCTIONS Aluminum Blinds - Standard - - Lift & Lock - 1 Deluxe 1 Traditional 1 Value & 1 Basic 2 Macro Thank you for your purchase. This blind has been custom built for you from the

More information

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Indoor Unit AQB18J6WC AQB24J2WC. Outdoor Unit UQB18J6WC UQB24J2WC

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Indoor Unit AQB18J6WC AQB24J2WC. Outdoor Unit UQB18J6WC UQB24J2WC AQB8J6WC_IM_E_25864 2006.4.4 3:29 PM Page 7 INSTALLATION MANUAL Indoor Unit AQB8J6WC AQB24J2WC Outdoor Unit UQB8J6WC UQB24J2WC ENGLISH FRANÇAIS ESPAÑOL Split-type Air Conditioner (Cooling and Heating)

More information

Installation Instructions

Installation Instructions Issue 1.2 August 2015 Balanced Flue Kit for NVx and VPC Industrial & Commercial Heating Systems. Installation Instructions H E A T I N G / / V E N T I L A T I O N / / A I R C O N D I T I O N I N G Page

More information

INSTALLATION OF DURAVENT POLYPRO SINGLE WALL POLYPROPYLENE VENTING SYSTEMS

INSTALLATION OF DURAVENT POLYPRO SINGLE WALL POLYPROPYLENE VENTING SYSTEMS SUPPLEMENT VENTING INSTRUCTIONS FOR INSTALLATION AND OPERATION INSTRUCTION MANUALS FOR THE FOLLOWING PRODUCT TYPES: HIGH EFFICIENCY CONDENSING COMMERCIAL, COMMERCIAL POWER DIRECT VENT, LIGHT DUTY COMMERCIAL

More information

Installation instructions for vented tumble dryer DOMESTIC. Dear Customer,

Installation instructions for vented tumble dryer DOMESTIC. Dear Customer, Dear Customer, Read these instructions carefully and completely before you install the machine. The installation should be carried out by a qualified person who is familiar with all local codes and ordinances

More information

LINE SET DUCT AND ACCESSORY PRODUCT CATALOG

LINE SET DUCT AND ACCESSORY PRODUCT CATALOG VAC LINE SET DUCT AND ACCESSORY PRODUCT CATALOG Correctly installing an air conditioner requires the use of dedicated accessories. When the customer invests in an air conditioner, he relies on the professional

More information

INSTALLATION AND OPERATION. -, 3. -is INSTRUCTIONS FOR COOLAIR S EVAP-PAD COOLING SYSTEM. Coo/ah AMERICAN COOLAIR CORPORATION

INSTALLATION AND OPERATION. -, 3. -is INSTRUCTIONS FOR COOLAIR S EVAP-PAD COOLING SYSTEM. Coo/ah AMERICAN COOLAIR CORPORATION I -, 3. -is INSTALLATION AND OPERATION INSTRUCTIONS FOR COOLAIR S EVAP-PAD COOLING SYSTEM e Coo/ah AMERICAN COOLAIR CORPORATION TABLE OF CONTENTS PAGE I. CONCEPT OF EVAPORATIVE COOLING....2 II. RECOMMENDEDTOOLS......3

More information

INSTALLATION INSTRUCTIONS. WOOD BLINDS 1-3/8, 2 and 2-3/8 SLAT SIZES. FAUX WOOD BLINDS 2 and 2-1/2 SLAT SIZES

INSTALLATION INSTRUCTIONS. WOOD BLINDS 1-3/8, 2 and 2-3/8 SLAT SIZES. FAUX WOOD BLINDS 2 and 2-1/2 SLAT SIZES INSTALLATION INSTRUCTIONS WOOD BLINDS 1-3/8, 2 and 2-3/8 SLAT SIZES FAUX WOOD BLINDS 2 and 2-1/2 SLAT SIZES STANDARD CORDLESS LIFT Thank you for your purchase. This blind has been custom built for you

More information

Dishwasher. Installation manual DW60M9990AP

Dishwasher. Installation manual DW60M9990AP Dishwasher manual DW60M9990AP DW9000M_DD68-00197B-00_EN.indd 1 6/1/2017 4:34:14 PM Contents Contents 3 What s included 3 requirements 7 Dimensions and specifications 9 Step-by-step installation 11 2 English

More information

Installation Instructions

Installation Instructions Wood Blinds Installation Instructions Heartland Woods Heartland Woods w/ Continuum *Click on any page to return to the Table of Contents* Heartland Woods Wood Blinds Mounting Inside or Outside Window Frame

More information

Installation. Leveling

Installation. Leveling Your refrigerator was packed carefully for shipment. Remove and discard shelf packaging and tape. Do not remove the serial plate. Location Do not install refrigerator near oven, radiator or other heat

More information

INVERTER SPLIT - TYPE

INVERTER SPLIT - TYPE INVERTER SPLIT - TYPE ISSUE No 2 DATE 04/09/08 P/No 2020323A2868 CONTENTS SAFETY PRECAUTIONS Warning 2 Operating temperature 2 BEFORE INSTALLATION Tools needed for installation 3 Items required for installing

More information

SUPPLEMENTARY INSTRUCTIONS

SUPPLEMENTARY INSTRUCTIONS www.burcam.com 2190 Dagenais Blvd.West TEL: 514.337.4415 LAVAL (QUEBEC) FAX: 514.337.4029 CANADA H7L 5X9 info@burcam.com SUPPLEMENTARY INSTRUCTIONS MODEL 450475 Dear consumer, We thank and congratulate

More information

Electrical cable Water supply tube Fittings for tube Coupler Teflon tape. Hole saw min. 2½" bit

Electrical cable Water supply tube Fittings for tube Coupler Teflon tape. Hole saw min. 2½ bit Installation Parts and Tools Parts not Provided Electrical cable Water supply tube Fittings for tube Coupler Teflon tape Air gap Wire nuts for 6-gauge wiring Hose clamp ⅞" UL approved strain relief Electrical

More information

FAUX WOOD BLINDS 2 & 2-1/2 SLAT SIZES

FAUX WOOD BLINDS 2 & 2-1/2 SLAT SIZES INSTALLATION INSTRUCTIONS FAUX WOOD BLINDS 2 & 2-1/2 SLAT SIZES STANDARD RECTANGULAR Thank you for your purchase. This blind has been custom built for you from the highest quality materials. To avoid errors

More information

HG-2000E HEAT GUN WATTS

HG-2000E HEAT GUN WATTS HG-2000E HEAT GUN 2.000 WATTS EN - INSTRUCTIONS Carefully read the instructions for use before you start using the machine. drivenbycare www.orfit.com 1 2 6 8 7 2 8 450 C 300 C 6 A E FE 550 C PVC (hard)

More information

Specialty Products. Gutter Guards. Pine Guard Gutter Protection System

Specialty Products. Gutter Guards. Pine Guard Gutter Protection System Specialty Products Gutter Guards Pine Guard Gutter Protection System Must be installed in conjunction with on new gutters only 18-Gauge expanded powder coated metal base (will not rust) Keep Pine needles

More information

CableReady

CableReady CableReady www.ppc-online.com 1 PPC - A Belden Brand is a manufacturing company serving the security, cable TV, home entertainment, commercial and broadcast industries. PPC Belden is recognized worldwide

More information

AOYG18LFC OUTDOOR UNIT INSTALLATION MANUAL INSTALLATION MANUAL. For authorized service personnel only. PART NO

AOYG18LFC OUTDOOR UNIT INSTALLATION MANUAL INSTALLATION MANUAL. For authorized service personnel only. PART NO AOYG8LFC OUTDOOR UNIT INSTALLATION MANUAL INSTALLATION MANUAL For authorized service personnel only. English PART NO. 93778639 93778639_IM.indb /20/20 6:07:25 PM AIR CONDITIONER OUTDOOR UNIT INSTALLATION

More information

Installation Manual PS-225 & PS-275

Installation Manual PS-225 & PS-275 Installation Manual PS-225 & PS-275 Table of Contents Pre-Uncrating Checklist... 1 Verifying System Requirements... 2 Verifying System Direction... 2 Verifying the Electrical Requirements... 2 Removal

More information

Air Conditioner. user installation & manual manual. imagine the possibilities

Air Conditioner. user installation & manual manual. imagine the possibilities ARFSSSBWK Series ARFSSSCUR AJ JNADCH Series Air Conditioner user installation & manual manual This manual is made with 100% recycled paper. imagine the possibilities Thank you for purchasing this Samsung

More information

Installation Instructions

Installation Instructions Installation Instructions Electric Drop-In Range JDS28, JDP39 Questions? Call 800.GE.CARES (800.432.2737) or Visit our Website at: ge.com BEFORE YOU BEGIN Read these instructions carefully and completely.

More information

Guide to using RAIN BARRELS

Guide to using RAIN BARRELS Guide to using RAIN BARRELS (Information compiled from a variety of resources) From this... Rain Barrels are one component of a water-efficient landscape.... to this. This information is provided by: James

More information

Kenya s Official Distributor of GutterFlow Products

Kenya s Official Distributor of GutterFlow Products Kenya s Official Distributor of GutterFlow Products The careful management of rainwater is becoming increasingly important. FlowPlumb provides a cost-effective yet aesthetically pleasing solution to rainwater

More information

Z-DENS Z-FLEX. Polypropylene Vent Systems for High Efficiency Condensing Appliances. Single Wall Rigid Flexible Liner Concentric

Z-DENS Z-FLEX. Polypropylene Vent Systems for High Efficiency Condensing Appliances. Single Wall Rigid Flexible Liner Concentric Z-FLEX Advanced Venting Solutions Z-DENS Polypropylene Vent Systems for High Efficiency Condensing Appliances Single Wall Rigid Flexible Liner Concentric Z-Flex Joins Forces with Cox Geelen Z-Flex North

More information

Disconnecting Your Downspouts to Improve Local Water Quality

Disconnecting Your Downspouts to Improve Local Water Quality Disconnecting Your Downspouts to Improve Local Water Quality Virginia gets an average of 45.22 inches of rain every year. For an average size home of 1,260 square feet, that amounts to approximately 35,500

More information

EVAC Commercial Marine Equipment TOILET TECHNICAL DATA EVAC 90, SQUATTING TOILET. To main vacuum line, connection Ø50.

EVAC Commercial Marine Equipment TOILET TECHNICAL DATA EVAC 90, SQUATTING TOILET. To main vacuum line, connection Ø50. Date: 25 Jan 2005 Doc. 1:114E TECHNICAL DATA 5979301 EVAC 90, SQUATTING To main vacuum line, connection Ø50 Service door 600 Push button Fresh water supply connection 1/2" MPT BSP 700 700 Flushing mechanism

More information

Installation Instructions

Installation Instructions Aluminum Blinds Installation Instructions Echelon, Traditions & Integra Aluminum Blinds 2 Metro Aluminum Blinds *Click on any page to return to the Table of Contents* Echelon, Traditions & Integra Aluminum

More information

Instantaneous Oil-Fired Water Heater. Installation Manual OM-148. (Type D)

Instantaneous Oil-Fired Water Heater. Installation Manual OM-148. (Type D) Instantaneous Oil-Fired Water Heater Installation Manual MODEL OM-148 (Type D) IMPORTANT THIS APPLIANCE SHOULD BE INSTALLED BY A LICENSED, AUTHORIZED PERSON(S) DUE TO THE NECESSITY OF MAKING ELECTRICAL,

More information

Farm Food Safety: Building an Easy Clean Produce Wash Table

Farm Food Safety: Building an Easy Clean Produce Wash Table Farm Food Safety: Building an Easy Clean Produce Wash Table Farmers are inventive people. When faced with a problem, their creative minds fire up and come up with solutions. This project is the result

More information

Venting of Gas Fired Equipment RV

Venting of Gas Fired Equipment RV PLEASE DO NOT BOOKMARK ANY ANYTIMECE WEBPAGES! Our system will remember the last page you viewed when logging out and back in but please DO NOT exit out when taking a test. Your place will NOT be saved.

More information

Installation Manual PS-200 & PS-201

Installation Manual PS-200 & PS-201 Installation Manual PS-200 & PS-201 Table of Contents Pre-Uncrating Checklist... 1 Verifying System Requirements... 2 Verifying System Direction... 2 Verifying the Electrical Requirements... 2 Removal

More information

The following report was prepared for the buyers of the home and property at 1400 Main St. Anywhere City, Tennessee. The inspection was conducted on

The following report was prepared for the buyers of the home and property at 1400 Main St. Anywhere City, Tennessee. The inspection was conducted on HOME PROPERTY SCAN INSPECTIONS The following report was prepared for the buyers of the home and property at 1400 Main St. Anywhere City, Tennessee. The inspection was conducted on January 11, 2010 and

More information

abt W Lamp Paraffine Oil n. 0,125 l/h 12 V = (11-14,5 V) 220 x 285 x 115 mm

abt W Lamp Paraffine Oil n. 0,125 l/h 12 V = (11-14,5 V) 220 x 285 x 115 mm SPECIFICATIONS Heat output Fuel - consumption Supply voltage Current consumption - start, 2 minutes Dimensions abt. 1200 W Lamp Paraffine Oil n. 0,125 l/h 12 V = (11-14,5 V) abt. 0,4 A abt. 5 A 220 x 285

More information

PowerVent. Installation manual (GB) English. Store this document in a safe place UK

PowerVent. Installation manual (GB) English. Store this document in a safe place UK PowerVent Installation manual (GB) Store this document in a safe place 959.034.03.UK GB Contents Blz Foreword 3 1. Introduction 3 2. CE declaration 4 3. SAFETY 4 3.1 General 4 3.2 Regulations 4 3.3 Precautions

More information

Aluminum Horizontal Blinds BOX BRACKET INSTALLATION

Aluminum Horizontal Blinds BOX BRACKET INSTALLATION Aluminum Horizontal Blinds BOX BRACKET INSTALLATION MOUNT THE INSTALLATION BRACKETS Mounting Options The installation brackets may be inside mounted, outside mounted or ceiling mounted. In all cases, level

More information

Installation and Care Instructions

Installation and Care Instructions Installation and Care Instructions 2" Horizontal Aluminum Blinds MagnaView Tilt Feature CONTENTS Getting Started................................................ 1 Mount the Installation s....................................

More information

Vertical Termination Part No: 3CGRVT 16 7/8" 18 Vent Pipe Extension Part No: 3CG18 9 7/8" Wall Hanger Part No: 3CGWH 7 7/8" 7 3/8"

Vertical Termination Part No: 3CGRVT 16 7/8 18 Vent Pipe Extension Part No: 3CG18 9 7/8 Wall Hanger Part No: 3CGWH 7 7/8 7 3/8 Corr/Guard Direct Vent Water Heater Vent/Air Intake System Installation and service must be performed by a qualified installer, service agency or the gas supplier. Installation must meet all state and

More information

Installation Manual EF5000 AUS & NZ

Installation Manual EF5000 AUS & NZ Installation Manual EF5000 AUS & NZ This manual is ONLY for fires with a serial No. from 80600 to 80999. Important: The appliance shall be installed in accordance with; Local gas fitting regulations Municipal

More information

Instructions for Operation and Maintenance of Containers

Instructions for Operation and Maintenance of Containers Instructions for Operation and Maintenance of Containers Container Handling 1. Containers are designed for transport on a flat loading area that is 2.5 m wide, which enables support of the load-bearing

More information

Siding Installation Guide

Siding Installation Guide GENUINE WOOD INSTALLATION GUIDE U.S. VERSION Siding Installation Guide U.S. VERSION This installation guide applies to Maibec textured-face finish and Maibec URBAHN brushed-face finish siding. For optimal

More information

INSTALLATION AND OPERATION MANUAL

INSTALLATION AND OPERATION MANUAL F OR I NGROUND P OOLS INSTALLATION AND OPERATION MANUAL How Solar Pool Heating Works Why SunHeater TM Works Best Using your pool pump, water is automatically pumped through the solar collectors. The water

More information

Insulated Panels. Highline Gutters. Installation guide

Insulated Panels. Highline Gutters. Installation guide Insulated Panels Highline Gutters Installation guide 2 Preparing for installation ingspan angular gutters are manufactured from galvanized metalsheet with single-side coating (polyester, Spectrum, plastisol).

More information

Installation Instructions

Installation Instructions Installation Instructions Type B Gas Vent Model E/R 3" 8" ECCO TYPE B GAS VENT AND ACCESSORIES ARE FOR USE ONLY WITH LISTED CATEGORY 1 GAS-FIRED APPLIANCES OR APPLIANCES LISTED FOR USE WITH TYPE B GAS

More information

Danfoss Self-limiting Heating Cables SLPG-10/26/33, SLPG-18, SLHW-55/70, SLPH-10

Danfoss Self-limiting Heating Cables SLPG-10/26/33, SLPG-18, SLHW-55/70, SLPH-10 MAKING MODERN LIVING POSSIBLE Installation Guide SLPG-10/26/33, SLPG-18, SLHW-55/70, SLPH-10 www.eh.danfoss.com Table of Contents 1 Introduction............................................. 3 1.1 Self-limiting

More information

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels Installation Instructions For the 18 Built-In Dishwasher and Front Color Panels Printed in USA 154232102 Before You Begin DO NOT INSTALL DISHWASHER UNTIL YOU HAVE READ ALL INSTRUCTIONS. FOR YOUR SAFETY,

More information

INSTALLATION. Glass Panel Doors (select models) CAUTION

INSTALLATION. Glass Panel Doors (select models) CAUTION Location Do not install refrigerator near oven, radiator or other heat source. If not possible, shield refrigerator with cabinet material. Do not install where temperature falls below 55 F (13 C) or rises

More information

User Manual for MullToa 10 and 25

User Manual for MullToa 10 and 25 User Manual for MullToa 10 and 25 User Manual for MullToa 10 and 25 Congratulations on your purchase of MullToa toilet Your bio-toilet is patented and manufactured in Sweden and the brand is MullToa.

More information

Installation Instructions

Installation Instructions Installation Instructions Self-Cleaning Radiant Electric Drop-In Range JDP47, JD968, JD900 If you have questions, call 1.800.GE.CARES or visit our website at: ge.com Before You Begin Read these instructions

More information

INSTALLATION AND OPERATIONS MANUAL

INSTALLATION AND OPERATIONS MANUAL email: info@uapc.com Main Office: Telephone: 757-461-0077 1140 Kingwood Ave, Norfolk, Virginia 23502 Telefax: 757-461-0808 Branch Offices: Telephone: 704-374-0600 4715 Stockholm Court, Charlotte, NC 28273

More information

FOR ENGCON STONE AND SCRAP HANDLING GRAB SK05ST-SK30ST THE WIDEST RANGE ON THE MARKET

FOR ENGCON STONE AND SCRAP HANDLING GRAB SK05ST-SK30ST THE WIDEST RANGE ON THE MARKET Instruction manual Stone and scrap handling grab SK05ST-SK30ST English FOR ENGCON STONE AND SCRAP HANDLING GRAB SK05ST-SK30ST THE WIDEST RANGE ON THE MARKET Increase your excavator s efficiency and precision

More information

INSTALLATION OF CENTROTHERM INNOFLUE SINGLE WALL POLYPROPYLENE VENTING SYSTEMS

INSTALLATION OF CENTROTHERM INNOFLUE SINGLE WALL POLYPROPYLENE VENTING SYSTEMS SUPPLEMENT VENTING INSTRUCTIONS FOR INSTALLATION AND OPERATING INSTRUCTION MANUALS 238 48384 00, 238 44727 00, 238 44445 00, 238 48144 00, 238 47936 00, 238 45917 00, 238 45637 00, 238 47448 00, 238 48071

More information

U tube models PTU 09, 12, 15, 25, 30, 35, 40, 45. single linear tube models PTS 09, 12, 15, 25, 30, 35, 40, 45

U tube models PTU 09, 12, 15, 25, 30, 35, 40, 45. single linear tube models PTS 09, 12, 15, 25, 30, 35, 40, 45 U tube models PTU 09, 2, 5, 25, 30, 35, 40, 45 & single linear tube models PTS 09, 2, 5, 25, 30, 35, 40, 45 installation, servicing & operating instructions INSTALLATION, SERVICING AND OPERATING INSTRUCTIONS

More information

Clear Installation guide

Clear Installation guide Clear 40010631-0938 ENG Installation guide ENG 1.1 1.2 1.3 A 1.4 1.5 1 < < < < A B 2.1 2.2 2.3 C 2.4 2.5 2 < < < < 3.1 3.2 3-3 3 < < < < Inhoudsopgave 1 Introduction... 6 2 Safety instructions... 6 3 Installation

More information

Natural Target Pruning. Making Proper Pruning Cuts

Natural Target Pruning. Making Proper Pruning Cuts Natural Target Pruning Making Proper Pruning Cuts Natural Target Pruning In this lesson we will learn: What is Natural Target Pruning Where to make Natural Target Pruning Cuts Why is it important to make

More information

Installation and Care Instructions

Installation and Care Instructions Installation and Care Instructions THANK YOU for purchasing a Hunter Douglas product. Your new blind has been custom built for you from the highest quality materials. Once in your window, it will provide

More information

Installation and Care Instructions

Installation and Care Instructions Installation and Care Instructions 2" Horizontal Aluminum Blinds MagnaView Tilt Feature Thank you for your purchase. Your new blinds have been custom built for you from the highest quality materials. Properly

More information

MULTI HEAT PUMP PANEL CONSOLE TYPE DUCTLESS INVERTER INDOOR UNIT INSTALLATION MANUAL. Models: CH09MCU230VI CH12MCU230VI CH18MCU230VI

MULTI HEAT PUMP PANEL CONSOLE TYPE DUCTLESS INVERTER INDOOR UNIT INSTALLATION MANUAL. Models: CH09MCU230VI CH12MCU230VI CH18MCU230VI MULTI DUCTLESS INVERTER HEAT PUMP PANEL CONSOLE TYPE INDOOR UNIT INSTALLATION MANUAL Models: CH09MCU230VI CH12MCU230VI CH18MCU230VI Thank you for choosing a C&H Multi Ductless Heat Pump! You can feel confident

More information

OWNERS INSTRUCTION MANUAL

OWNERS INSTRUCTION MANUAL OWNERS INSTRUCTION MANUAL 132CM/52 Classic INSTALLATION OPERATION MAINTENANCE CAUTION READ INSTRUCTIONS CAREFULLY FOR SAFE INSTALLATION AND FAN OPERATION. IF UNSURE CONSULT A QUALIFIED ELECTRICIAN SUITABLE

More information

Ingenious bathroom solutions now and in the future

Ingenious bathroom solutions now and in the future Ingenious bathroom solutions now and in the future For more than 30 years Pressalit Care has worked to diminish limitations with knowledge, products and advice. The objective is a better life for people

More information

Always make sure to check the heating film before, during, and after installation of the floor covering.

Always make sure to check the heating film before, during, and after installation of the floor covering. Installation of floor heating film for ceramic tiles, granite and other stone or composite flooring Read through this entire manual before starting installation. All electrical connections must be made

More information

Casper Hoop House Workshop 12 Ft. x 36 Ft. Del Jimenez. 12ft x 36ft Hoop House 2

Casper Hoop House Workshop 12 Ft. x 36 Ft. Del Jimenez. 12ft x 36ft Hoop House 2 Casper Hoop House Workshop 12 Ft. x 36 Ft. Del Jimenez 12ft x 36ft Hoop House 2 Hoop House 12 Ft. x 36 Ft. HOOP HOUSE The Hoop House, Cold Frame and High Tunnel can be basically the same structure with

More information

ZC Kit AGP Pellet Insert

ZC Kit AGP Pellet Insert ZC Kit AGP Pellet Insert Compatibility AGP Pellet Insert Lopi AGP Pellet Insert Overview Packing List ZC Can Rear Panel ZC Can Top/Side Panel Bottom Panel (Fiber Board with Steel) (40) # 8 x 3/8 Type A

More information

IMPORTANT INFORMATION. Revised Dishwasher Installation Instructions

IMPORTANT INFORMATION. Revised Dishwasher Installation Instructions IMPORTANT INFORMATION Revised Dishwasher Installation Instructions To obtain a revised copy of the entire Dishwasher User s Manual, go to www.eurotechappliances.com. SPECIAL EDITION 11-20-02 SAVE THESE

More information

OPTION CA1, CA2, AND CA3 POWER VENTERS

OPTION CA1, CA2, AND CA3 POWER VENTERS R HAZARD INTENSITY LEVELS 1. DANGER: Failure to comply will result in severe personal injury or death and/or property damage. 2. WARNING: Failure to comply could result in severe personal injury or death

More information

This site is based on a but applies to all 1971-on Saab 99 and Saab 900.

This site is based on a but applies to all 1971-on Saab 99 and Saab 900. by Mark Jeter updated: December 8, 2004 originally web-published June 27, 2001 This document shows how the original waterpump in a Saab "B" engine can be eliminated and replaced with a reliable, efficient

More information

CEILING FED RISER RAIL KIT. Installation Guide. tritonshowers.co.uk/digital

CEILING FED RISER RAIL KIT. Installation Guide. tritonshowers.co.uk/digital CEILING FED RISER RAIL KIT Installation Guide tritonshowers.co.uk/digital 2181533B - December 2017 CONTENTS General installation & safety notes (please read)... Installation options... Main components...

More information

Tankless Water Heater Direct Vent Sweet Termination Installation Instructions

Tankless Water Heater Direct Vent Sweet Termination Installation Instructions Tankless Water Heater Direct Vent Sweet Termination Installation Instructions The Sweet Termination Direct Vent System is designed for use with the following models: RTG-74DV-1 RUTG-74DV -1 RMTG-74DV -1

More information

Hakki Pilke Raven spare parts manual

Hakki Pilke Raven spare parts manual 1 ENGLISH Hakki Pilke Raven spare parts manual Valimotie 1, FI-85800 Haapajärvi, FINLAND Tel. +358 8 772 7300, Fax +358 8 772 732 info@maaselankone.fi, www.maaselankone.fi 2 Table of contents 1 Upper section

More information

YOUR GUIDE. Product Maintenance Guide. How to look after your product. PVC-U Windows, Doors & Conservatories

YOUR GUIDE. Product Maintenance Guide. How to look after your product. PVC-U Windows, Doors & Conservatories YOUR GUIDE Product Maintenance Guide How to look after your product PVC-U Windows, Doors & Conservatories 02 Product Maintenance Guide WELCOME Thank you for investing in our products. Your investment will

More information

FIREPRO FIRESTOPPING AND PENETRATION SEALS PRODUCT GUIDE

FIREPRO FIRESTOPPING AND PENETRATION SEALS PRODUCT GUIDE Superior 4 in 1 insulation (59) Y November 2008 (K22) FIREPRO FIRESTOPPING AND PENETRATION SEALS PRODUCT GUIDE Superior 4 in 1 insulation STRAIGHT FROM THE SOURCE S MOUTH... Introducing the most reliable

More information

Installation and Maintenance Instructions

Installation and Maintenance Instructions Commercial & Industrial Positive Pressure or Condensing AL 29-4C Stainless Steel High Challenge Special Gas Vent Also for Natural Draft Appliances 3",4",5",6",7",8",9",10" and 12" Diameter Special Gas

More information

INSTALLATION INSTRUCTIONS. WOOD BLINDS 1-3/8, 2 and 2-3/8 SLAT SIZES. COMPOSITE FAUX WOOD BLINDS 2 and 2-1/2 SLAT SIZES

INSTALLATION INSTRUCTIONS. WOOD BLINDS 1-3/8, 2 and 2-3/8 SLAT SIZES. COMPOSITE FAUX WOOD BLINDS 2 and 2-1/2 SLAT SIZES INSTALLATION INSTRUCTIONS WOOD BLINDS 1-3/8, 2 and 2-3/8 SLAT SIZES COMPOSITE FAUX WOOD BLINDS 2 and 2-1/2 SLAT SIZES POLYMER FAUX WOOD BLINDS 2 and 2-1/2 SLAT SIZES STANDARD CORDLESS LIFT Thank you for

More information

RIVERA P5000. Folding awning P5000

RIVERA P5000. Folding awning P5000 RIVERA Beschreibung Description min. 200 cm max. 500 cm 8 25 Wall mounting 8 25 Top fixation min. 200 cm max. 700 cm Terrace roof system comprising an aluminium extruded structure and integrated fabric

More information

SPEEDI DUCT AND HVAC INSTALLATION ACCESSORIES

SPEEDI DUCT AND HVAC INSTALLATION ACCESSORIES PRODUCT CATALOG SPEEDI DUCT AND HVAC INSTALLATION ACCESSORIES littlegiant.com SPEEDI DUCT AND HVAC INSTALLATION ACCESSORIES CATALOG Speedi Duct Products... 2 Speedi Duct Benefits...2 Starter Kit...3 Starter

More information

INSTALLATION INSTRUCTIONS FOR 6532 SERIES PACKAGE HEAT PUMP

INSTALLATION INSTRUCTIONS FOR 6532 SERIES PACKAGE HEAT PUMP INSTALLATION INSTRUCTIONS FOR 6532 SERIES PACKAGE HEAT PUMP RV Products A Division of Airxcel, Inc. P.O. Box 4020 Wichita, KS 67204 1976-360 (1-02) PP TABLE OF CONTENTS 1. Warnings......................................................

More information

HE220, HE260 Humidifier Installation Kit

HE220, HE260 Humidifier Installation Kit HE220, HE260 Humidifier Installation Kit WELCOME To the comfortable world of humidified air. When you use your Honeywell humidifier, you notice that your skin is not as dry, and that your scratchy throat

More information

InverterFlex Series Multi-Zone Ducted Indoor Unit B-VFH09DA-1 B-VFH12DA-1 B-VFH18DA-1 B-VFH24DA-1

InverterFlex Series Multi-Zone Ducted Indoor Unit B-VFH09DA-1 B-VFH12DA-1 B-VFH18DA-1 B-VFH24DA-1 INSTALLATION, OPERATION & MAINTENANCE MANUAL InverterFlex Series Multi-Zone Ducted Indoor Unit B-VFH09DA-1 B-VFH12DA-1 B-VFH18DA-1 B-VFH24DA-1 Heat Controller 1900 Wellworth Ave. Jackson, MI 49203 (517)787-2100

More information

Instantaneous Oil-Fired Water Heater. Installation Manual OM-148. (Type B)

Instantaneous Oil-Fired Water Heater. Installation Manual OM-148. (Type B) Instantaneous Oil-Fired Water Heater Installation Manual MODEL OM-148 (Type B) IMPORTANT THIS APPLIANCE SHOULD BE INSTALLED BY A LICENSED, AUTHORIZED PERSON(S) DUE TO THE NECESSITY OF MAKING ELECTRICAL,

More information

INSTALLATION OF VENTING SYSTEM COMPONENTS WARNING

INSTALLATION OF VENTING SYSTEM COMPONENTS WARNING INSTALLATION OF VENTING SYSTEM COMPONENTS WARNING When installing the EVERHOT IGI model series direct vent water heaters, use only EVERHOT vent/air intake system kits and components. Installation and service

More information

Installation Manual. KS Series KS09 KS12 KS18 KS24 KS28. J3387_Kaden_Installer_Manual_ indd 1

Installation Manual. KS Series KS09 KS12 KS18 KS24 KS28. J3387_Kaden_Installer_Manual_ indd 1 Wall Mounted AIR CONDITIONER Installation Manual KS Series KS09 KS12 KS18 KS24 KS28 J3387_Kaden_Installer_Manual_050917.indd 1 5/09/2017 9:07 AM J3387_Kaden_Installer_Manual_050917.indd 2 5/09/2017 9:07

More information

SPLIT WALL-MOUNTED AIR CONDITIONER

SPLIT WALL-MOUNTED AIR CONDITIONER SPLIT WALL-MOUNTED AIR CONDITIONER MODELS: WS 090C / WS 090H / WS00H EMAILAIR I N S T A L L A T I O N I N S T R U C T I O N S ACCESSORIES SUPPLIED WITH THE AIR CONDITIONER 2 LOCATION OF INDOOR AND OUTDOOR

More information

Why Rain Barrels? STORMWATER RAIN BARRELS

Why Rain Barrels? STORMWATER RAIN BARRELS Why Rain Barrels? STORMWATER - + - RAIN BARRELS Let s Talk About Stormwater Pollution: Stormwater pollution is caused by water washing over the land picking up contaminants and directly or indirectly depositing

More information

Standard Installation Manual

Standard Installation Manual Standard Installation Manual READ THIS MANUAL BEFORE INSTALLATION Caution If you plan to install your solar heater system on a roof be sure you are experienced in working on roofs and have the proper safety

More information

20/20 Home Inspections. Photo Attachments

20/20 Home Inspections. Photo Attachments Page 1 of 9 Damaged roof shingles. Improper rof shingle installation; improper overlapping. Improper layout. Improper flashing at plumbing vent stack. Wrong size jack. No storm collar. Improper installation

More information

TOYOTOMI U.S.A., INC. P.O. Box 176, Brookfield, CT

TOYOTOMI U.S.A., INC. P.O. Box 176, Brookfield, CT Instantaneous Kerosene Fired Water Heater ACCESSORY INSTRUCTION MANUAL FOR EXTENSION PIPE KIT SH-70UFF PART# 20476496 TOYOTOMI U.S.A., INC. P.O. Box 176, Brookfield, CT 06804-0176 NOTE: Remote flue pipe

More information

Flue & Flue Kits for NVx, VPC & NVS

Flue & Flue Kits for NVx, VPC & NVS Doc Ref: M505 Issue 2.1 Mar 2018 Flue & Flue Kits for NVx, VPC & NVS Industrial & Commercial Heating Systems Installation Manual www.powmatic.co.uk +44 (0) 1460 53535 info@powrmatic.co.uk powrmatic Certificate

More information

protection Constant wattage heating cables Self-regulating heating cables Temperature controllers

protection Constant wattage heating cables Self-regulating heating cables Temperature controllers snow & ice protection Constant wattage heating cables Self-regulating heating cables Temperature controllers Protection of roofs, gutters and downpipes Snow and ice protection systems protect against:

More information

Installation and Homeowners Guide

Installation and Homeowners Guide Installation and Homeowners Guide Underscore Bathroom Heater S450 S450 K-77315T-G-MZ/K-77283T-G-MZ KOHLER CHINA INVESTMENT CO., LTD NO.158, JIANG CHANG SAN ROAD, JING'AN DISTRICT, SHANGHAI, PRC POST CODE:

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS - Wall-mount indoor unit - OPERATING LIMITS Cooling Maximum conditions Heating Maximum conditions Outdoor temperature : 122 F (50 C) D.B. Outdoor temperature : 75 F (24 C) D.B.

More information

FLANGED CORR/GUARD CORR/GUARD INSTALLATION INSTRUCTIONS

FLANGED CORR/GUARD CORR/GUARD INSTALLATION INSTRUCTIONS CORR/GUARD INSTALLATION INSTRUCTIONS This symbol on the nameplate means this product is listed by Underwriters Laboratories Inc. Tested to UL1738 / CAN / ULCS636-08 Listing No. MH26687 Testing No. 11EN

More information

Table of Contents. What to Expect with. Mounting Options. Tools Needed. Preparation. Wiring. Downrod.

Table of Contents.   What to Expect with. Mounting Options. Tools Needed. Preparation. Wiring. Downrod. Table of Contents www.casablancafanco.com What to Expect with Your Installation Congratulations on purchasing your new Casablanca ceiling fan! It will provide comfort and performance in your home or office

More information

LED Flex Tube Assembly Guide

LED Flex Tube Assembly Guide LED Flex Tube Assembly Guide WARNING: NEVER APPLY POWER TO FLEX TUBE WHILE COILED!!! Please read entire guide before beginning assembly or installation. Licensed electricians should provide all electrical

More information