1 Furring Channel Resilient Mount - Direct Fixing Acoustic attenuation in wall construction is achieved by a combination of density or mass to block and reflect sound, as well as insulation in cavities to absorb sound, minimising noise transfer through the wall. Particularly low frequencies, noise can transfer through solid structures. This means that sound can pass through the wall studs, floor and top plates into the next room. Resilient Mounts are affixed to the wall frame with Furring Channels attached, and acoustic plasterboard is then mounted to the frame. This discontinuous construction method dramatically, reduces impact noise and structure borne noise with minimal increase in wall thickness. An associated benefit of the use of Resilient Mounts is the air void created which also provides noise reduction. Resilient Mount 2RD1 2RD1 are an acoustic resilient mounting bracket for Furring Channels, purposed to reduce airborne vibration and structure-borne vibration in wall and ceiling applications. 2RD1 unique design guards against structure-borne vibrations transferring into the body of the Resilient Mount, because of its strong column design providing a small percentage of contact surface area with the structure or substrate it is fixed to. This aids in absorbing and breaking up airborne sound at its transfer point. The 2RD1 can be fixed directly to the structure in wall and ceiling applications with screws or masonry sleeve anchors. The 2RD1 as part of the Acoustic Mounts range, complements the integrated wall and ceiling system, and have been manufactured in compliance with the Australian Furring Channel Resilient Mount - Direct Fixing 2RD1 Furring Channel Resilient Mount - Direct Fixing

2 Furring Channel to Top Cross Rail Resilient Mount Acoustic attenuation in wall construction is achieved by a combination of density or mass to block and reflect sound, as well as insulation in cavities to absorb sound, minimising noise transfer through the wall. Particularly low frequencies, noise can transfer through solid structures. This means that sound can pass through the wall studs, floor and top plates into the next room. Resilient Mounts are affixed to the wall frame with Furring Channels attached, and acoustic plasterboard is then mounted to the frame. This discontinuous construction method dramatically, reduces impact noise and structure borne noise with minimal increase in wall thickness. An associated benefit of the use of Resilient Mounts is the air void created which also provides noise reduction. Resilient Mount 2RD5 2RD5 are an acoustic resilient mounting bracket installed between the Top Cross Rail and Furring Channel. The 2RD5 is designed for suspended ceiling systems under timber joists or concrete slabs and purposed to reduce airborne vibration and structure-borne vibration in wall and ceiling applications. The Resilient Mount 2RD5 as part of the Acoustic Mounts range, complements the integrated wall and ceiling system, and have been manufactured in compliance with the Australian National Construction and New Zealand Building Codes. Furring Channel to Top Cross Rail Resilient Mount 2RD5 Furring Channel to Top Cross Rail Resilient Mount

3 Furring Channel to Purlin Resilient Mount Acoustic attenuation in wall construction is achieved by a combination of density or mass to block and reflect sound, as well as insulation in cavities to absorb sound, minimising noise transfer through the wall. Particularly low frequencies, noise can transfer through solid structures. This means that sound can pass through the wall studs, floor and top plates into the next room. Resilient Mounts are affixed to the wall frame with Furring Channels attached, and acoustic plasterboard is then mounted to the frame. This discontinuous construction method dramatically, reduces impact noise and structure borne noise with minimal increase in wall thickness. An associated benefit of the use of Resilient Mounts is the air void created which also provides noise reduction. Resilient Mount 2RD6 2RD6 is an adjustable acoustic resilient mounting bracket for Furring Channels being suspended below purlins or trusses, purposed to reduce airborne vibration and structureborne vibration in ceiling applications. 2RD6 unique sound cell design guards against structureborne vibrations transferring into the body of the Resilient Mount, because of its strong column design providing a small percentage of contact surface area with the structure or substrate it is fixed to. This aids in absorbing and breaking up airborne sound at its transfer point. The 2RD6 can be fixed directly to trusses and purlins providing adjustability. Provided with a variety of holes for different fasteners. The 2RD6 as part of the Acoustic Mounts range, complements the integrated wall and ceiling system, and have been manufactured in compliance with the Australian Furring Channel to Purlin Resilient Mount 2RD6 Furring Channel to Purlin Resilient Mount

4 Furring Channel Resilient Mount - Right Angle Acoustic attenuation in wall construction is achieved by a combination of density or mass to block and reflect sound, as well as insulation in cavities to absorb sound, minimising noise transfer through the wall. Particularly low frequencies, noise can transfer through solid structures. This means that sound can pass through the wall studs, floor and top plates into the next room. Resilient Mounts are affixed to the wall frame with Furring Channels attached, and acoustic plasterboard is then mounted to the frame. This discontinuous construction method dramatically, reduces impact noise and structure borne noise with minimal increase in wall thickness. An associated benefit of the use of Resilient Mounts is the air void created which also provides noise reduction. Resilient Mount 2RD7 2RD7 is an acoustic resilient mounting bracket for reducing airborne and structure-borne vibration in internal wall and ceiling applications. It can brace an acoustic wall to the structure without compromising sound and vibration transmission requirements, and can be used in direct fix ceiling applications with inserting wire rod into the hole in the longer leg. 2RD7 unique sound cell design guards against structureborne vibrations transferring into the body of the Resilient Mount, because of its strong column design providing a small percentage of contact surface area with the structure or substrate it is fixed to. This aids in absorbing and breaking up airborne sound at its transfer point. The 2RD7 is provided with several slotted holes in bracket fixing surface, suitable for direct fixing or inserting suspension rod for suspended ceiling systems. The 2RD7 as part of the Acoustic Mounts range, complements the integrated wall and ceiling system, and have been manufactured in compliance with the Australian Furring Channel Resilient Mount - Right Angle 2RD7 Furring Channel Resilient Mount - Right Angle

5 Furring Channel Resilient Mount - Joiner Bracket Acoustic attenuation in wall construction is achieved by a combination of density or mass to block and reflect sound, as well as insulation in cavities to absorb sound, minimising noise transfer through the wall. Particularly low frequencies, noise can transfer through solid structures. This means that sound can pass through the wall studs, floor and top plates into the next room. Resilient Mounts are affixed to the wall frame with Furring Channels attached, and acoustic plasterboard is then mounted to the frame. This discontinuous construction method dramatically, reduces impact noise and structure borne noise with minimal increase in wall thickness. An associated benefit of the use of Resilient Mounts is the air void created which also provides noise reduction. Resilient Mount 2RD8 2RD8 is an acoustic resilient mounting bracket, purposed to reduce airborne vibration and structure-borne vibration in an internal chase wall application where acoustical bridging is required. Using the 2RD8 improves the strength and rigidity of chase walls, allowing both walls to support each other whilst remaining completely acoustically isolated. 2RD8 unique sound cell design guards against structureborne vibrations transferring into the body of the Resilient Mount, because of its strong column design providing a small percentage of contact surface area with the structure or substrate it is fixed to. This aids in absorbing and breaking up airborne sound at its transfer point. The 2RD8 can be fixed to studs to provide strength and rigidity on chase walls whilst remaining completely acoustically isolated. It is also supplied assembled, with a variety of holes sizes for different fasteners depending the installation environment. The 2RD8 as part of the Acoustic Mounts range, complements the integrated wall and ceiling system, and have been manufactured in compliance with the Australian Furring Channel Resilient Mount - Joiner Bracket 2RD8 Furring Channel Resilient Mount - Joiner Bracket

6 Furring Channel Resilient Mount Threaded Fastener Channels for acoustic walls and soundproof rooms, where a Acoustic attenuation in wall construction is achieved by a combination of density or mass to block and reflect sound, as well as insulation in cavities to absorb sound, minimising noise transfer through the wall. Particularly low frequencies, noise can transfer through solid structures. This means that sound can pass through the wall studs, floor and top plates into the next room. Resilient Mounts are affixed to the wall frame with Furring Channels attached, and acoustic plasterboard is then mounted to the frame. This discontinuous construction method dramatically, reduces impact noise and structure borne noise with minimal increase in wall thickness. An associated benefit of the use of Resilient Mounts is the air void created which also provides noise reduction. Resilient Mount 2RD1T Resilient Mount 2RD1T is an acoustic resilient mounting assembly with an adjacent through bolt for ceiling systems. The 2RD1T greatly reduces sound and vibration transmission between the ceiling system and the supporting structure by creating acoustic isolation between them. The Resilient Mount 2RD1T as part of the Acoustic Mounts range, complements the integrated wall and ceiling system, and have been manufactured in compliance with the Australian Furring Channel Resilient Mount Threaded Fastener 2RD1T Furring Channel Resilient Mount Threaded Fastener

7 Furring Channel Adjustable BettaFix Resilient Mount Channels for acoustic walls and soundproof rooms, where a high level of noise reduction is required. Acoustic attenuation in wall construction is achieved by a combination of density or mass to block and reflect sound, as well as insulation in cavities to absorb sound, minimising noise transfer through the wall. Particularly low frequencies, noise can transfer through solid structures. This means that sound can pass through the wall studs, floor and top plates into the next room. Resilient Mounts are affixed to the wall frame with Furring Channels attached, and acoustic plasterboard is then mounted to the frame. This discontinuous construction method dramatically, reduces impact noise and structure borne noise with minimal increase in wall thickness. An associated benefit of the use of Resilient Mounts is the air void created which also provides noise reduction. 2RD15 The 2RD15 is an acoustic resilient mounting bracket for Furring Channels, purposed to reduce airborne vibration and structure-borne vibration in wall applications. Like the standard 2D15 Adjustable BettaFix Clip, this Furring Channel bracket allows for plumb installation of Furring Channel on walls. The stand-off of the Furring Channel can be adjusted by up to 18mm with the use of this clip. The 2RD15 unique design guards against structure-borne vibrations transferring into the body of the Resilient Mount, which aids in absorbing and breaking up airborne sound at its transfer point. The 2RD15 as part of the Acoustic Mounts range, complements the integrated wall and ceiling system, and have been manufactured in compliance with the Australian National Construction and NZ Building Codes. All products designed to achieve optimal performance when part of the integrated system. The complete premium walls and ceilings solution, Building Excellence, start to finish. The genuine Resilient Mount clips are exclusively available through the network of Group distributors. Visit intex.com.au for the complete range of Resilient Mounts. Furring Channel Adjustable BettaFix Resilient Mount 2RD15 Furring Channel Adjustable BettaFix Resilient Mount

8 Resil-A-Mat Resilient Rubber Mat Channels for acoustic walls and soundproof rooms, where a Acoustic attenuation in wall construction is achieved by a combination of density or mass to block and reflect sound, as well as insulation in cavities to absorb sound, minimising noise transfer through the wall. Particularly low frequencies, noise can transfer through solid structures. This means that sound can pass through the wall studs, floor and top plates into the next room. Resilient Mounts are affixed to the wall frame with Furring Channels attached, and acoustic plasterboard is then mounted to the frame. This discontinuous construction method dramatically, reduces impact noise and structure borne noise with minimal increase in wall thickness. An associated benefit of the use of Resilient Mounts is the air void created which also provides noise reduction. Resilient Mat RESIL045 RESIL045 is an impact rubber mat for structural isolation between metal framing components and building structures. It is approximately 35mm x 40mm x 7mm in dimension, and is supplied with a 6.5mm hole in the centre for a range of fasteners. The Resilient Mat RESIL045 as part of the Acoustic Mounts range, complements the integrated wall and ceiling system, and have been manufactured in compliance with the Australian Resil-A-Mat Resilient Rubber Mat RESIL045 Resil-A-Mat Resilient Rubber Mat

Ceiling Systems are not Trafficable unless stated, and are designed to carry the weight of the ceiling only.

Ceiling Systems are not Trafficable unless stated, and are designed to carry the weight of the ceiling only. Concealed Ceiling Steel Products The Peer Industries concealed ceiling system utilises furring channels, top cross rails, rod and suspension clips to provide a flush ceiling finish. This concealed ceiling

More information

Ceiling Systems 6 Intex Price Guide

Ceiling Systems 6 Intex Price Guide 6 Intex Price Guide PRODUCT CODE DESCRIPTION LENGTH PACK SIZE PRICE PER PRICE PER STOCK PRICE PER PRICE PER (MM) METRE LENGTH PACK METRE LENGTH P R I M A R Y C H A N N E L S Used as a primary suspension

More information

SOUND ISOLATION SOLUTIONS

SOUND ISOLATION SOLUTIONS SOUND ISOLATION SOLUTIONS Studco Australia Resilmount Unique patented thermoplastic rubber with sound cell design M237R Patents pending: US 11/872574 AU 2007226819 2 T: 1800 788 326 Email: sales@resilmount.com.au

More information

Concealed Ceiling Systems

Concealed Ceiling Systems Concealed Ceiling Systems M27R Top Cross Rail Can be rolled to create curved ceilings. M534 Spring Hanger Used for suspension of concealed ceiling systems MBF Betafix Clip For adjustment when fixing furring

More information

CONCEALED CEILING SYSTEMS INSTALLATION GUIDE

CONCEALED CEILING SYSTEMS INSTALLATION GUIDE CONCEALED CEILING SYSTEMS INSTALLATION GUIDE rondo key-lock CONCEALED CEILING SYSTEMS VARIOUS KEY-LOCK COMPONENTS INTRODUCTION Whether you re looking to direct fix or fully suspend your plasterboard ceiling,

More information

Peer Industries Concealed Ceiling systems

Peer Industries Concealed Ceiling systems Peer Industries Concealed Ceiling systems Technical Manual Index General information/ Warranty and design considerations Engineering design certification Technical services Certification, standards and

More information

GENIE CLIP TYPE RST. Resilient Sound Isolation Clip INSTALLATION INSTRUCTIONS

GENIE CLIP TYPE RST. Resilient Sound Isolation Clip INSTALLATION INSTRUCTIONS GENIE CLIP TYPE RST Resilient Sound Isolation Clip INSTALLATION INSTRUCTIONS NOTE If at any time there is a question or concern as to the installation methods please contact Pliteq Inc or your local representative.

More information

key-lock installation guide key-lock Concealed Suspended Ceiling Systems

key-lock installation guide key-lock Concealed Suspended Ceiling Systems key-lock installation guide key-lock Concealed Suspended Ceiling Systems rondo key-lock Installation 1. Spacings Table 1 has been prepared for a batten spacing of 600mm. Confirm with your lining distributor

More information

Knauf Direct Bonding and Metal Furring

Knauf Direct Bonding and Metal Furring Knauf Direct Bonding and Metal Furring Knauf Direct Bonding and Metal Furring Linings are the simplest and quickest of drylining systems to install. They are suitable for most brick, block and concrete

More information

SonusClip Installation for walls or ceilings on wood or steel framing. Installation Instructions for Wall & Ceilings

SonusClip Installation for walls or ceilings on wood or steel framing. Installation Instructions for Wall & Ceilings SonusClip Installation for walls or ceilings on wood or steel framing If you have questions during installation please contact Regupol at 717-675-2190 Sound Isolation Clips SonusClip Sound Isolation Clip

More information

SCREWFIX SUSPENSION SYSTEM

SCREWFIX SUSPENSION SYSTEM SCREWFIX SUSPENSION SYSTEM www.usgboral.com 1 JUNE 2015 Apartments Hotels Retail Malls Banks Medical Industrial Food Preparation Areas For a high quality, lightweight alternative to timber framed ceilings,

More information

INTERNAL FRAMING PROFILES

INTERNAL FRAMING PROFILES INTERNAL FRAMING PROFILES Ceiling Furring Sections Dry-Wall Partitioning Sections Angle Beads And Accessories About the Hadley Group Hadley Industries is one of Europe s leading manufacturers of cold rollformed

More information

INSTALLATION DO S AND DON TS

INSTALLATION DO S AND DON TS 4.0 NOISE CONTROL Figure 4.1. - Transitions Abrupt transitions immediately adjacent to an attenuator will cause the attenuator pressure drop to increase. Ensure transitions close to attenuators are gradual

More information

Regupol SonusClip Installation Guide for Walls or Ceilings with Wood or Steel Framing

Regupol SonusClip Installation Guide for Walls or Ceilings with Wood or Steel Framing Regupol SonusClip Installation Guide for Walls or Ceilings with Wood or Steel Framing If you have questions during installation please contact Regupol at 717-675-2190 regupol-acoustics.com 800.537.8737

More information

Instruction Manual ICTS-6 HT. In-Ceiling Theater System Speaker - 3 T W E E T E

Instruction Manual ICTS-6 HT. In-Ceiling Theater System Speaker - 3 T W E E T E +3 0-3 ICTS-6 HT In-Ceiling Theater System Speaker - 3 0 T W E +3 E T E R Instruction Manual 2 Safety Precautions Table of Contents 2 Model ICTS-6 HT 2 Important Safety Information 3 Features 3 Speaker

More information

CEILING SYSTEMS. Between us, ideas become reality. Armstrong Blue Tongue Aluminium Grid and Perimeter/Pelmet Systems

CEILING SYSTEMS. Between us, ideas become reality. Armstrong Blue Tongue Aluminium Grid and Perimeter/Pelmet Systems CEILING SYSTEMS Between us, ideas become reality Armstrong Blue Tongue Aluminium Grid and Perimeter/Pelmet Systems Suspension Systems Content Modular Ceiling Systems Pages 4 5 One Way Ceiling Systems Pages

More information

Assembly, Installation & Watering Guide VERTICAL GARDEN SYSTEM. Version 4. Product Version. Gro-Wall 4.0.

Assembly, Installation & Watering Guide VERTICAL GARDEN SYSTEM. Version 4.  Product Version. Gro-Wall 4.0. Product Version Gro-Wall 4.0 Document ID 06-09-2012/4:16PM/CU VERTICAL GARDEN SYSTEM Version 4 Assembly, Installation & Watering Guide www.atlantiscorp.com.au Contents Gro-Wall Components Additional Materials

More information

1 What is the name of the tool shown in the diagram? Basin wrench Footprint wrench Stilson wrench Torque wrench.

1 What is the name of the tool shown in the diagram? Basin wrench Footprint wrench Stilson wrench Torque wrench. 36 Exam Success Plumbing and Heating 6189-11 and 6189-21 Sample test The sample test below is for paper 6189-005, Understand and carry out site preparation, and pipework fabrication techniques for domestic

More information

WARM WATER UNDERFLOOR HEATING SYSTEMS. Guidance Notes

WARM WATER UNDERFLOOR HEATING SYSTEMS. Guidance Notes WARM WATER UNDERFLOOR HEATING SYSTEMS Guidance Notes 02 WARM WATER UNDERFLOOR HEATING SYSTEMS Introduction Underfloor heating systems consist of a series of pipes which are integrated into the floor structure

More information

installation, operation & Maintenance manual acb ceiling-mounted cassette models

installation, operation & Maintenance manual acb ceiling-mounted cassette models installation, operation & Maintenance manual acb ceiling-mounted cassette models built on innovation Active chilled beams Active Chilled Beam cassette style beams are induction driven, heating and cooling

More information

SAPS GUARDRAIL CONCRETE

SAPS GUARDRAIL CONCRETE SAPS GUARDRAIL CONCRETE The SAPS guardrail for concrete applications attaches to an embedded anchor and provides a 5000 lb point of tie-off. The 42 inch and 60 inch models meet OSHA height requirements.

More information

INSTALLATION INSTRUCTIONS Trade-Wind In-Line Blower / Ventilators

INSTALLATION INSTRUCTIONS Trade-Wind In-Line Blower / Ventilators INSTALLATION INSTRUCTIONS Trade-Wind In-Line Blower / Ventilators Models: PSX006XL PSD008XL PSD010XL CONTENTS: Part 1 - Planning The Installation Part 2 - Securing The Blower / Ventilator Part 3 - Electrical

More information

LUCCI AIRFUSION RESORT DC CEILING FAN

LUCCI AIRFUSION RESORT DC CEILING FAN LUCCI AIRFUSION RESORT DC CEILING FAN INSTALLATION OPERATION MAINTENANCE WARRANTY INFORMATION CAUTION READ INSTRUCTIONS CAREFULLY FOR SAFE INSTALLATION AND FAN OPERATION. V 2. 0 p u b l i c a t i o n o

More information

EW25 EW30 EW35 USER & INSTALLATION MANUAL. Model. Model. Model

EW25 EW30 EW35 USER & INSTALLATION MANUAL. Model. Model. Model ON-WALL SPEAKERS Model EW25 Model EW30 Model EW35 USER & INSTALLATION MANUAL Introduction Congratulations on your purchase of an EMP Tek EW25, 30 or 35 on-wall Speaker! Your speaker is the result of many

More information

PAC International, Inc. RSIC-1 FS System 37" and Larger (200 lb max)

PAC International, Inc. RSIC-1 FS System 37 and Larger (200 lb max) 1 2 3 4 5 SIDE VIEW 1. RSIC-1 with retro Washer 2. 7/8" Drywall Furring Channel (By others) 3. ¾ Finish Grade Plywood (Painted, stained, or covered with fabric/carpet) ( By others) 4. Flat Screen wall

More information

GIVE A FAN A CHANCE Installation Dos & Don ts

GIVE A FAN A CHANCE Installation Dos & Don ts GIVE A FAN A CHANCE Installation Dos & Don ts 1 Give a Fan a Chance Installation Dos & Don ts Choosing the right fan for the right application is paramount, which is why every product in our range is designed

More information

BLUE TONGUE ALUMINIUM GRID AND PERIMETER/PELMET SYSTEMS

BLUE TONGUE ALUMINIUM GRID AND PERIMETER/PELMET SYSTEMS BLUE TONGUE ALUMINIUM GRID AND PERIMETER/PELMET SYSTEMS SUSPENSION SYSTEMS CONTENT Modular Ceiling Systems Pages 4 5 One Way Ceiling Systems Pages 6 7 Two Way Ceiling Systems Page 8 Perimeters / Wall Angles

More information

SPECIFICATION DELETED SECTION CENTRIFUGAL HVAC FANS

SPECIFICATION DELETED SECTION CENTRIFUGAL HVAC FANS SECTION 23 34 16 CENTRIFUGAL HVAC FANS PART 1 - GENERAL 1.01 RELATED DOCUMENT A. Drawings and general provisions of the contract, including General and Special Conditions and Division 01 Specification

More information

installation, operation & Maintenance manual Floor-mounted Induction units acb 30/35

installation, operation & Maintenance manual Floor-mounted Induction units acb 30/35 installation, operation & Maintenance manual Floor-mounted Induction units acb 30/35 built on innovation acb 30 & 35 Active Chilled Beam Models ACB30 & ACB35 are designed for installation in the ceiling

More information

Cascade Sliding Systems Formulating Character and Distinction

Cascade Sliding Systems Formulating Character and Distinction Cascade Sliding Systems Formulating Character and Distinction Cascade Sliding Systems The Cascade Sliding Door Series offer a range of cavities and sliding track systems designed for both the commercial

More information

CEILING SYSTEMS. Between us, ideas become reality. Armstrong Blue Tongue Aluminium Grid and Perimeter/Pelmet Systems

CEILING SYSTEMS. Between us, ideas become reality. Armstrong Blue Tongue Aluminium Grid and Perimeter/Pelmet Systems CEILING SYSTEMS Between us, ideas become reality Armstrong Blue Tongue Aluminium Grid and Perimeter/Pelmet Systems Suspension Systems Content Modular Ceiling Systems Pages 4 5 One Way Ceiling Systems Pages

More information

Installation Manual. Top of Pole Mount Edition v1.01. For models:

Installation Manual. Top of Pole Mount Edition v1.01. For models: Top of Pole Mount Installation Manual 2014 Edition v1.01 For models: UNI-TP/02 UNI-TP/02A UNI-TP/03 UNI-TP/04 UNI-TP/04A UNI-TP/06 UNI-TP/06LL UNI-TP/08 UNI-TP/08LL UNI-TP/10 UNI-TP/10LL UNI-TP/12 UNI-TP/12LL

More information

FIREPRO SoftSeal System

FIREPRO SoftSeal System PENETRATION AND AND LINEAR LINEAR JOINTS JOINTS APRIL JULY 2015 FIREPRO SoftSeal System www.rockwool.co.uk PENETRATION AND LINEAR JOINTS FIREPRO Range The ROCKWOOL FIREPRO SoftSeal system is part of this

More information

LUCCI AIRFUSION FRASER DC CEILING FAN

LUCCI AIRFUSION FRASER DC CEILING FAN LUCCI AIRFUSION FRASER DC CEILING FAN INSTALLATION OPERATION MAINTENANCE WARRANTY INFORMATION CAUTION READ INSTRUCTIONS CAREFULLY FOR SAFE INSTALLATION AND FAN OPERATION. V2.0-EN-Published on 03. 2018

More information

Vertical Blinds. Step by Step Installation Instructions

Vertical Blinds. Step by Step Installation Instructions Vertical Blinds Step by Step Installation Instructions Everything You Need A Smooth Set-Up We want you to love your new window coverings and that includes having a smooth installation experience. We recommend

More information

INSTALLATION INSTRUCTIONS USER GUIDE

INSTALLATION INSTRUCTIONS USER GUIDE INSTALLATION INSTRUCTIONS USER GUIDE Chimney Pyramid Rangehood HC60PLX4 and HC90PLX4 models NZ AU CONTENTS Safety and warnings 3 Installation instructions 5 Operating instructions 14 Cleaning and maintenance

More information

Electrician Installation Manual EM-E Ceiling Fan

Electrician Installation Manual EM-E Ceiling Fan Electrician Installation Manual CEILING FAN MUST BE INSTALLED BY A LICENSED ELECTRICIAN (NO OTHER PERSONS SHOULD ATTEMPT TO INSTALL THIS FAN) *Electricians are recommended to tick off all items on the

More information

ILLUSTRATIONS ARE FOR REFERENCE ONLY AND ARE SUBJECT TO CHANGE WITHOUT NOTICE ITEM P/N DESCRIPTION

ILLUSTRATIONS ARE FOR REFERENCE ONLY AND ARE SUBJECT TO CHANGE WITHOUT NOTICE ITEM P/N DESCRIPTION TC-0 TURN PLATE TC-0 TURN PLATE 0 0 0 TC-0-000 TURNTABLE TC-0-00 TURNTABLE, TC-0 TC-0-00 SCREW, M X TC-0-00 COVER, TC-0 TC-0-00 RETAINING PIN TC-0-00 CLAMP TC-0-00 CLAMP SEAT TC-0-0 CLAMP SEAT, TC-0 TC-0-00

More information

Eliminator Series. SE400E and SE800E ELECTRONIC AIR PURIFICATION SYSTEM. Electrostatic Precipitators for Commercial Applications

Eliminator Series. SE400E and SE800E ELECTRONIC AIR PURIFICATION SYSTEM. Electrostatic Precipitators for Commercial Applications ELECTRONIC AIR PURIFICATION SYSTEM Eliminator Series SE400E and SE800E INSTALLATION OPERATION SERVICE Electrostatic Precipitators for Commercial Applications 101 McNeill Road Sanford, NC 27330 (919) 775-2201

More information

Perimeos. Ceiling Recess. decor. systems

Perimeos. Ceiling Recess. decor. systems Ceiling Recess decor systems Ceiling Recess Perimeos is a revolutionary ceiling perimeter solution, for concealing blinds and curtain tracks. A key feature is the SpeedClip mounting channel. This allows

More information

Description. Construction

Description. Construction LUH LUH PDS Horizontal Unit Heater 2.6 to 45 kw 208, 240, 277 480, 600 Volts Single or 3-Phase 8,900 to 153,600 BTU/Hour Wall or Ceiling Mounting Meets UL and CSA Requirements (600V CSA Certified Only)

More information

IB1100 and IB850 Installation Manual AUSTRALIAN EDITION

IB1100 and IB850 Installation Manual AUSTRALIAN EDITION IB1100 and IB850 Installation Manual AUSTRALIAN EDITION Important: The appliance shall be installed in accordance with; This installation instruction booklet Local gas fitting regulations Municipal building

More information

KUH. Horizontal Unit Heater. Applications. Description

KUH. Horizontal Unit Heater. Applications. Description KUH KUH PDS Horizontal Unit Heater 2.6 kw to 45 kw 208, 240, 277 480, 600 Volts Single or 3-Phase 8,900 to 153,600 BTU/Hour Wall or Ceiling Mounting Meets UL and CSA Requirements (600V CSA Certified Only)

More information

Hood Depot Internatioonal, Inc., Phone S. Powerline Road, Deerfield Beach, FL

Hood Depot Internatioonal, Inc., Phone S. Powerline Road, Deerfield Beach, FL The Kitchen Cool by Hood Depot is a conditioned make up air unit design with flexibility, form and function kept in mind. Our unit offers a variety of configurations that allow the customer to customize

More information

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number: SECTION 233423 - HVAC POWER VENTILATORS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Provisions of the Contract and of the Contract Documents apply to this Section. 1.2 PERFORMANCE REQUIREMENTS A. Operating

More information

OPERATING AND INSTALLATION INSTRUCTIONS FOR WHISPAIR RANGEHOODS UTILISING ON BOARD FAN MOTOR UNITS

OPERATING AND INSTALLATION INSTRUCTIONS FOR WHISPAIR RANGEHOODS UTILISING ON BOARD FAN MOTOR UNITS A I R E N G I N E E R E D OPERATING AND INSTALLATION INSTRUCTIONS FOR WHISPAIR RANGEHOODS UTILISING ON BOARD FAN MOTOR UNITS CONGRATULATIONS Congratulations and thank you for choosing a Whispair rangehood.

More information

UMA-1020 Light Weight Suspended Ceiling Kit

UMA-1020 Light Weight Suspended Ceiling Kit INSTALLATION INSTRUCTIONS UMA-1020 Light Weight Suspended Ceiling Kit The provides a sturdy support for LCD/DLP hanging brackets (and certain other products weighing less than 50 pounds) when installing

More information

INSTALLATION OF DURAVENT POLYPRO SINGLE WALL POLYPROPYLENE VENTING SYSTEMS

INSTALLATION OF DURAVENT POLYPRO SINGLE WALL POLYPROPYLENE VENTING SYSTEMS SUPPLEMENT VENTING INSTRUCTIONS FOR INSTALLATION AND OPERATION INSTRUCTION MANUALS FOR THE FOLLOWING PRODUCT TYPES: HIGH EFFICIENCY CONDENSING COMMERCIAL, COMMERCIAL POWER DIRECT VENT, LIGHT DUTY COMMERCIAL

More information

INSTALLATION, INSTRUCTION AND SERVICE MANUAL

INSTALLATION, INSTRUCTION AND SERVICE MANUAL COBALT SMART-HEAT ELECTRIC HEATER BY BROMIC INSTALLATION, INSTRUCTION AND SERVICE MANUAL SUITABLE FOR ELECTRIC HEATER MODELS: COBALT 2000W, 3000W, 4000W- AND COBALT 6000W Version 1.0 USA! IMPORTANT READ

More information

SuperKlean Washdown Products

SuperKlean Washdown Products DURAREEL DR8 & DR8S INSTALLATION AND MAINTENANCE INSTRUCTIONS **DO NOT THROW AWAY AFTER INSTALLATION** **SAVE AND DISPLAY PROMINENTLY WHERE THIS EQUIPMENT IS USED** GENERAL WARNINGS High pressure and hot

More information

INSTALLATION INSTRUCTIONS FOR 6532 SERIES PACKAGE HEAT PUMP

INSTALLATION INSTRUCTIONS FOR 6532 SERIES PACKAGE HEAT PUMP INSTALLATION INSTRUCTIONS FOR 6532 SERIES PACKAGE HEAT PUMP RV Products A Division of Airxcel, Inc. P.O. Box 4020 Wichita, KS 67204 1976-360 (1-02) PP TABLE OF CONTENTS 1. Warnings......................................................

More information

INSTALLATION INSTRUCTIONS USER GUIDE

INSTALLATION INSTRUCTIONS USER GUIDE INSTALLATION INSTRUCTIONS USER GUIDE Tilted wall cooker hood HT90GHB2 model GB IE CONTENTS Introduction 3 Safety and warnings 4 Installation instructions 8 About your cooker hood Energy efficiency 18

More information

Industrial Cable Support HALOGEN-FREE - FIRE RETARDANT - OPTICAL FIBER DUCTING

Industrial Cable Support HALOGEN-FREE - FIRE RETARDANT - OPTICAL FIBER DUCTING INTRODUCTION Duct+Lid () TC1279-21X Ducting Warren & Brown Technologies Optical Fibre Ducting System is designed to ensure network integrity and to satisfy the requirements for Optical Fibre stress relief:

More information

VSA/VSB & KSA/KSB Series Air Doors

VSA/VSB & KSA/KSB Series Air Doors READ AND SAVE THESE INSTRUCTIONS No.: II-230 Date: October, 2007 VSA/VSB & KSA/KSB Series Air Doors Installation & Maintenance Instructions WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY

More information

Installation Instructions

Installation Instructions Installation Instructions For Free Standing NoFrost Combined Refrigerator-Freezers CS 1660 7082 653-00 PLEASE READ AND FOLLOW THESE INSTRUCTIONS These instructions contain Warning and Caution statements.

More information

Tube Clamp Submittal Information Revision A: July 25, 2013

Tube Clamp Submittal Information Revision A: July 25, 2013 Tube Clamp Revision A: July 25, 2013 Polypropylene (PP) Tube Clamps secure ½" and ¾" Uponor crosslinked polyethylene (PEX-a) tubing products. Suspension Standard Description Part Number A B C Weight Tube

More information

F116 (Series 16000) Self-Contained Ductable Commercial Air Cleaner

F116 (Series 16000) Self-Contained Ductable Commercial Air Cleaner F116 (Series 16000) Self-Contained Ductable Commercial Air Cleaner FEATURES PRODUCT DATA Variety of filter configurations available to customize the air cleaner for any application. Three-speed direct

More information

THE MONTICELLO CEILING FAN INSTALLATION INSTRUCTIONS

THE MONTICELLO CEILING FAN INSTALLATION INSTRUCTIONS THE MONTICELLO CEILING FAN INSTALLATION INSTRUCTIONS Please read and save these instructions These instructions are to be used in the installation of the following QUORUM INTERNATIONAL fans... The Monticello

More information

HVAC LEGEND HVAC ABBREVIATIONS PLUMBING LEGEND PLUMBING ABBREVIATIONS PRELIMINARY NOT FOR CONSTRUCTION

HVAC LEGEND HVAC ABBREVIATIONS PLUMBING LEGEND PLUMBING ABBREVIATIONS PRELIMINARY NOT FOR CONSTRUCTION GENERAL NOTES SPECIFICATIONS LEGEND SYMBOL DESCRIPTION ABBREV. SYMBOL DESCRIPTION ABBREV. SYMBOL DESCRIPTION ABBREV. ABBREVIATIONS PLUMBING LEGEND SYMBOL DESCRIPTION ABB. SYMBOL DESCRIPTION ABB. SYMBOL

More information

READ AND SAVE THESE INSTRUCTIONS. SE400E & SE800E Smoke Eliminator. TRION

READ AND SAVE THESE INSTRUCTIONS. SE400E & SE800E Smoke Eliminator. TRION READ AND SAVE THESE INSTRUCTIONS SE400E & SE800E Smoke Eliminator TRION www.trioniaq.com Smoke Eliminator SE400E & SE800E Table of Contents Design Introduction... 2 Specifications... 2 The Filter System...

More information

INSTALLATION INSTRUCTIONS USER GUIDE

INSTALLATION INSTRUCTIONS USER GUIDE INSTALLATION INSTRUCTIONS USER GUIDE Standard Rangehood HF60LX4 and HF60LW4 model NZ AU CONTENTS Safety and warnings 3 Installation instructions 5 Operating instructions 13 Cleaning and maintenance 14

More information

Smoke extraction duct of sheet steel

Smoke extraction duct of sheet steel Smoke extraction duct of sheet steel The accessories that are available, as for example inspection openings, steel grilles, plenum boxes, ceiling diffusers, splitter attenuators, bends, tees and connecting

More information

KITCHENS FREQUENTLY ASKED QUESTIONS PAGE 1 KITCHEN CABINETS

KITCHENS FREQUENTLY ASKED QUESTIONS PAGE 1 KITCHEN CABINETS PAGE 1 KITCHEN CABINETS Q. How long are your cabinets guaranteed for? A. All of our cabinets come with a manufacturer s guarantee of 25 years, so you can be sure that your UK manufactured cabinet is of

More information

Ceiling Sweep Fan Assembly Instructions

Ceiling Sweep Fan Assembly Instructions Ceiling Sweep Fan Assembly Instructions CSF Series Installation Note: This fan must be installed by a licenced electrical contractor Improperly installed ceiling sweep fans can be dangerous and expensive

More information

OPERATING AND INSTALLATION INSTRUCTIONS FOR WHISPAIR RANGEHOODS UTILISING REMOTE FAN MOTOR UNITS

OPERATING AND INSTALLATION INSTRUCTIONS FOR WHISPAIR RANGEHOODS UTILISING REMOTE FAN MOTOR UNITS A I R E N G I N E E R E D OPERATING AND INSTALLATION INSTRUCTIONS FOR WHISPAIR RANGEHOODS UTILISING REMOTE FAN MOTOR UNITS CONGRATULATIONS Congratulations and thank you for choosing a Whispair rangehood.

More information

DENON HEOS. Accessories for

DENON HEOS. Accessories for Accessories for DENON HEOS SoundXtra is the brainchild of the London-based team behind Flexson the bestselling brand of accessories for SONOS and shares the same high quality, innovation and attention

More information

Designpanel ACOUSTIC PERFORATED PLASTERBOARD WITH AIR PURIFYING FOR CEILINGS AND WALLS

Designpanel ACOUSTIC PERFORATED PLASTERBOARD WITH AIR PURIFYING FOR CEILINGS AND WALLS Designpanel ACOUSTIC PERFORATED PLASTERBOARD WITH AIR PURIFYING FOR CEILINGS AND WALLS SYSTEM Reg.nr. 5001 Contents Disclaimer Products manufactured and systems designed by Knauf are produced in accordance

More information

TECTUM Direct-Attach Ceiling and Wall Panels Assembly and Installation Instructions for 1" Thick Direct-Attach Wall and Ceiling Panels

TECTUM Direct-Attach Ceiling and Wall Panels Assembly and Installation Instructions for 1 Thick Direct-Attach Wall and Ceiling Panels TECTUM Direct-Attach Ceiling and Wall Panels Assembly and Installation Instructions for 1" Thick Direct-Attach Wall and Ceiling Panels TECTUM DIRECT-ATTACH WALL AND CEILING PANELS STANDARD ITEMS: Long

More information

Installation Instructions

Installation Instructions Installation Instructions KFN 9855 ide en - CA Installation, repair and maintenance work should be performed by a Miele authorized service technician in accordance with national and local safety regulations

More information

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION EXHAUST FANS

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION EXHAUST FANS PART 0 A/E INSTRUCTIONS 0.01 DESIGN REQUIREMENTS A. Placement within a mechanical room is required for all major mechanical equipment. Only small units may be roof-mounted, and shall be made as inconspicuous

More information

LUCCI AIRFUSION QUEST II CEILING FAN

LUCCI AIRFUSION QUEST II CEILING FAN LUCCI AIRFUSION QUEST II CEILING FAN WITH IR REMOTE INSTALLATION OPERATION MAINTENANCE WARRANTY INFORMATION CAUTION READ INSTRUCTIONS CAREFULLY FOR SAFE INSTALLATION AND FAN OPERATION. V1.0 QUEST II IR

More information

GREEN LOO DRY COMPOSTING TOILET Owners Installation Operation Manual. for the. GT 120 Family and GT 330

GREEN LOO DRY COMPOSTING TOILET Owners Installation Operation Manual. for the. GT 120 Family and GT 330 GREEN LOO DRY COMPOSTING TOILET Owners Installation Operation Manual for the GT 120 Family and GT 330 2 INSTALLATION PLANNING It's all in the planning! For proper operation of the toilet you should consider

More information

SECTION GYPSUM PLASTER

SECTION GYPSUM PLASTER SECTION 09210 PART I - GENERAL 1.01 DESCRIPTION A. Scope: Work under this Section shall include all materials and installation for support of gypsum plaster used as a finish for partitions and ceilings

More information

Pole Mounting System Installation & Certification Manual

Pole Mounting System Installation & Certification Manual Pole Mounting System Installation & Certification Manual IronRidge Pole Mount Installation Guide... 2 IronRidge Certification Letter... 17 IronRidge Wet Stamped Drawing... 18 IronRidge Foundation Addendum...

More information

For our present, For their future. Version 11.04

For our present, For their future. Version 11.04 For our present, For their future. SFH-S1 Series Solar Water Heater Assembly Manual Content http://www.sunflower-solar.com/ 1. FEATURES...3 2. SOLAR WATER HEATER SIZE AND WEIGHT...4 3. HOW TO TRANSPORT

More information

LUCCI AIRFUSION AIRLIE II ECO SERIES CEILING FAN

LUCCI AIRFUSION AIRLIE II ECO SERIES CEILING FAN LUCCI AIRFUSION AIRLIE II ECO SERIES CEILING FAN INSTALLATION OPERATION MAINTENANCE WARRANTY INFORMATION CAUTION READ INSTRUCTIONS CAREFULLY FOR SAFE INSTALLATION AND FAN OPERATION. V1.0 EN Published on

More information

Food Premises - Structural Specifications

Food Premises - Structural Specifications Food Premises - Structural Specifications Floors, Walls and Ceilings Floors Provide a floor surface with a material suited to the process: easily cleanable a light colour Floor to wall join in the food

More information

TOP AND CABINET PARTS

TOP AND CABINET PARTS TOP AND CABINET PARTS AUTOMATIC WASHER 3 10 Printed in U.S.A. (drd) (psw) 1 Part No. Rev. A TOP AND CABINET PARTS 1 Literature Parts W10157503 Use & Care Guide W10177425 Tech Sheet W10157501 Energy Guide

More information

Metal Cassette Ceiling with BEKA Heating and Cooling Mats

Metal Cassette Ceiling with BEKA Heating and Cooling Mats TI-K2 Short Description Metal Cassette Ceiling with BEKA Heating and Cooling Mats 1. General Modern office- and business facilities must be cooled mostly throughout the whole year because of the internal

More information

Cool air quietly and efficiently. A guide to buying and operating an air conditioner

Cool air quietly and efficiently. A guide to buying and operating an air conditioner Cool air quietly and efficiently A guide to buying and operating an air conditioner Cool air quietly and efficiently Noise from air conditioners can be a serious issue between neighbours. If an air conditioner

More information

2015 MECHANICAL CODE REQUIREMENTS

2015 MECHANICAL CODE REQUIREMENTS 2015 MECHANICAL CODE REQUIREMENTS ANTRIM COUNTY BUILDING DEPARTMENT PO BOX 188 205 CAYUGA STREET BELLAIRE, MI 49615 (231) 533-8373 FAX (231) 533-6041 Mechanical requirements for residential buildings per

More information

CEILING SYSTEMS [Between us, ideas become reality.] CI/SfB (35) Xy October OPTIMA Canopy

CEILING SYSTEMS [Between us, ideas become reality.] CI/SfB (35) Xy October OPTIMA Canopy CEILING SYSTEMS [Between us, ideas become reality.] CI/SfB (35) Xy October 2008 OPTIMA Canopy Create, Accentuate, Define Optima Canopy is a mineral panel, pre-formed into a convex, concave, square, circle,

More information

Installation Instructions

Installation Instructions Installation Instructions For Free Standing NoFrost Combined Refrigerator-Freezers CS 1640, CS 1400 7083 229-00 Important PLEASE READ AND FOLLOW THESE INSTRUCTIONS These instructions contain Warning and

More information

Vault Accessories Deluxe Kit

Vault Accessories Deluxe Kit Vault Accessories Deluxe Kit Instructions #1031640 Product #222498 A. B. D. C. E. A. Hygrometer B. 12 Dehumidifier C. Large Hanging Organizer D. Cordless Automatic Vault Light E. Magnetic Barrel Rest F.

More information

E. Luminaire: Complete lighting fixture, including ballast housing if provided.

E. Luminaire: Complete lighting fixture, including ballast housing if provided. SECTION 16511 - INTERIOR LIGHTING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and other Division 16 Specification

More information

Victory Home Improvements

Victory Home Improvements Photo Book When you choose a Victory patio, verandah or carport you are choosing the result of two decades of research and development. Uniquely 100% Australian BlueScope Steel and Australia s first all

More information

GENERAL INSTRUCTION SAFETY DIRECTIVES INSTALLATION INSTRUCTION SAFETY DIRECTIVES GENERAL INSTRUCTION

GENERAL INSTRUCTION SAFETY DIRECTIVES INSTALLATION INSTRUCTION SAFETY DIRECTIVES GENERAL INSTRUCTION GENERAL INSTRUCTION SAFETY DIRECTIVES INSTALLATION INSTRUCTION SAFETY DIRECTIVES Using the air handling unit... Free space for service and repair work... GENERAL INSTRUCTION Checking prior to commissioning...3

More information

Radiant Ceiling. Metawell Klimadecke 1

Radiant Ceiling. Metawell Klimadecke 1 Radiant Ceiling Metawell Klimadecke 1 Grid ceiling and high-gloss sail in a branch of the Sparkasse (Munich) Cooling and heating ceilings Conventional air-conditioning systems barely fulfil the more stringent

More information

Installation Manual Universal Top-of-Pole Mount UNI-TP/02

Installation Manual Universal Top-of-Pole Mount UNI-TP/02 Installation Manual Universal Top-of-Pole Mount UNI-TP/02 Solar Mounting Solutions UNI-TP/02 April 2008 www.ironridge.com 2008 IronRidge, Inc. All Rights Reserved Version 1.0 2 Universal Top-of-Pole Mount

More information

FAQ Frequently Asked Questions

FAQ Frequently Asked Questions FAQ Frequently Asked Questions Guaranteed solution in writing Q. We must meet a local noise ordinance in order to get our permit. How can I be guaranteed to meet that requirement? A. Ask about our guaranteed

More information

Timber in construction Eurocode 5 Span tables and guidelines

Timber in construction Eurocode 5 Span tables and guidelines Standard Recommendation S.R. 71:2015 Timber in construction Eurocode 5 Span tables and guidelines NSAI 2015 No copying without NSAI permission except as permitted by copyright law. I.S. xxx: Irish Standard

More information

Horizontal Blinds Installation Instructions

Horizontal Blinds Installation Instructions Horizontal Blinds Installation Instructions Mounting Options Inside mount: Blind is mounted inside the window frame, either to the top of the frame or to the sides. Outside mount: Blind is mounted either

More information

TC 222 TIRE CHANGER SPARE PART LIST 01

TC 222 TIRE CHANGER SPARE PART LIST 01 TC 222 TIRE CHANGER SPARE PART LIST 0 No. on Part No. Name Qua. Spec. 699000736 Vertical arm 2 699000737 Hex shaft, vertical arm 3A 699000725 Assembly - locking cylinder 4 699000738 Lock plate horizontal

More information

JM Aerofoil Fans Bulletin JMA60-05

JM Aerofoil Fans Bulletin JMA60-05 www.howden.com JM Aerofoil Fans Bulletin JMA60-05 Introduction The high performance JM Aerofoil Fan Benefits of the JM Aerofoil Fan include compactness, low cost, high efficiency and rugged design. Availability

More information

40LM Hz INSTALLATION, START-UP AND SERVICE INSTRUCTIONS CHILLED WATER FAN COIL UNIT

40LM Hz INSTALLATION, START-UP AND SERVICE INSTRUCTIONS CHILLED WATER FAN COIL UNIT Carrier International Sdn. Bhd. Malaysia INSTALLATION, START-UP AND SERVICE INSTRUCTIONS CHILLED WATER FAN COIL UNIT 40LM 120-200 50Hz CONTENTS: Physical Data & Dimension 1-3 Safety Considerations 4 Rigging

More information

SAFETY AND INSTALLATION MANUAL MODEL 8100

SAFETY AND INSTALLATION MANUAL MODEL 8100 SAFETY AND INSTALLATION MANUAL ENERGY RECOVERY VENTILATORS MODEL 8100 Provides year-round fresh air Recovers 77% of the apparent heating or cooling energy from the exhausted air See Warnings Page 3 Table

More information

HVAC Equipment Access Equipment Location

HVAC Equipment Access Equipment Location City of Lancaster- Building Department 121 East Chestnut Street, Suite 102, Lancaster, Ohio 43130-3825 (740) 687-6649, Fax (740) 681-5030 Web site: www.ci.lancaster.oh.us/dept/building HVAC Heating, Ventilating,

More information

Method Statement. General Site preparation by others: Preparation for screed system by others: Preparation for plate system by others:

Method Statement. General Site preparation by others: Preparation for screed system by others: Preparation for plate system by others: Method Statement. The One Stop Solution for Underfloor Heating. General Site preparation by others: Work areas to receive UFH must be watertight, dry, clean and clear of any debris or moveable obstructions.

More information

INSTALLATION, INSTRUCTION AND SERVICE MANUAL

INSTALLATION, INSTRUCTION AND SERVICE MANUAL PLATINUM SMART-HEAT ELECTRIC HEATER SERIES II BY BROMIC INSTALLATION, INSTRUCTION AND SERVICE MANUAL AVAILABLE IN 2300W & 3400W VERSION Original Instructions Version 3.2 AU IMPORTANT READ THIS MANUAL CAREFULLY.

More information

LUH HORIZONTAL FAN-FORCED UNIT HEATER

LUH HORIZONTAL FAN-FORCED UNIT HEATER LUH HORIZONTAL FAN-FORCED UNIT HEATER VERSATILE, FAN-FORCED HEATING FOR COMMERCIAL AND INDUSTRIAL COMFORT HEAT APPLICATIONS Horizontal airflow Wall or ceiling mounting Self-contained Totally enclosed fan

More information