1 Linear LED surface light for wall washing and grazing

2 Linear LED surface light for wall washing and grazing linear LED lighting fixtures are ideal for surface grazing and wall-washing applications that require high-quality solid red, green, blue, or amber light. Featuring Powercore technology, processes power directly from line voltage, eliminating the need for external power supplies. A space-efficient, low-profile extruded aluminum housing and flexible mounting options allow discreet placement within architectural niches of many different shapes and sizes. Tailor light output to specific applications is available in standard 1 ft and 4 ft exterior-rated housings, and standard 10º x 60º and 30º x 60º beam angles. High-performance illumination and beam quality Superior beam quality offers striation-free saturation as close as 6 in (152 mm) from fixture placement with no visible light scalloping between fixtures. Universal power input range ecolor Graze Powercore accepts line voltage input of 100, 120, , and 277 VAC. Support for installations requiring conduit to fixtures Conduit fixtures have flying leads and threaded openings for 1/2 in NPT conduit to support installations in North America where conduit is required. Dimming capability Patented DIMand technology offers smooth dimming capability with selected commercially available reverse-phase ELV-type dimmers. Wide range of custom configurations Additional fixture lengths and beam angles are available as custom configurations. See the Ordering Information specification sheet for complete details. Versatile installation options Constant torque locking hinges offer simple position control from various angles without special tools. 2 Product Guide

3 E For help estimating the light output and distribution of ecolor lighting fixtures, please contact Philips Color Kinetics Applications Engineering Services at support@colorkinetics.com. E To calculate the number of fixtures your specific installation can support, download the Configuration Calculator from Specifications Due to continuous improvements and innovations, specifications may change without notice. Item Specification 1 ft (305 mm) 4 ft (1.2 m) Output Beam Angle 10 x 16 / 30 x 60 Electrical Control Physical Certification and Safety Input Voltage Power Consumption Dimming Dimensions (Height x Width x Depth) 120 / / 277 VAC, 50 / 60 Hz 15 W maximum at full output, steady state 60 W maximum at full output, steady state Compatible with selected commercially available reverse-phase ELV-type dimmers* 2.7 x 12 x 2.8 in (69 x 305 x 71 mm) 2.7 x 48 x 2.8 in (69 x 1219 x 71 mm) Weight 2.7 lb (1.2 kg) 10.8 lb (4.9 kg) Housing Lens Fixture Connectors Mounting Temperature Ranges Humidity Fixture Run Lengths Certification Environment Extruded anodized aluminum Clear polycarbonate Integral male / female waterproof connectors Multi-positional, constant torque locking hinges F ( C) Operating F ( C) Startup F ( C) Storage 0 95%, non-condensing 110 VAC 120 VAC 220 VAC 240 VAC UL / cul, FCC (120 VAC only), CE, CCC Dry / Damp / Wet Location, IP66 Configuration: 1 ft (305 mm) fixtures installed end-to-end, 20 A circuit, standard 50 ft (15.2 m) Leader Cable * Refer to for specific details. These figures, provided as a guideline, are accurate for this configuration only. Changing the configuration can affect the fixture run lengths. 2.8 in (71 mm) 12 in (305 mm) / 48 in (1219 mm) 3.3 in (84 mm) 5.4 in (137 mm) / 41.4 in (1052 mm) 2.1 in (53 mm) 2.7 in (69 mm) 1.75 in (44 mm) 2.25 in (57 mm).88 in (22 mm) 1.94 in (49 mm) 1.38 in (35 mm).38 in (9.5 mm) 2.36 in (60 mm).28 in (7.2 mm) x4 Substrate 1.4 in (39 mm).38 in (9.5 mm).38 in (9.5 mm).88 in (22 mm) 2.36 in (60 mm) 1.38 in (35 mm).22 in (5.5 mm) x6 Fixture.813 in (21 mm) Product Guide 3

4 Fixtures and Accessories For standard fixtures, a complete system includes Leader Cables to connect the first fixture in a series to power or a junction box; optional Jumper Cables to add space between fixtures in a series; and 3-conductor copper wire to connect junction boxes to power if installing in parallel. For Conduit fixtures, a complete system includes 1/2 in NPT conduit, 3-conductor copper wire, and junction boxes as needed. You can control all fixtures with commercially available on / off switches and selected commercially available reverse-phase ELV-type dimmers. Build-to-Order Configurations In addition to the standard configurations listed here, build-toorder configurations are also available with non-standard options. See the Ordering Information sheet at for complete information. Component Available Non-Standard Options Color Royal Blue Length 2 ft, 3 ft Beam Angle 9 x 9, 15 x 30, 60 x 30, 90 x 60 Fixtures Fixture Length Red Green Blue Amber Item Number Philips 12NC Item Number Philips 12NC Item Number Philips 12NC Item Number Philips 12NC 10 x 60 Beam Angle 120 VAC VAC 277 VAC Conduit / 120 VAC Conduit / 277 VAC 120 VAC VAC 277 VAC Conduit / 120 VAC Conduit / 277 VAC 1 ft (305 mm) ft (1.2 m) ft (305 mm) ft (1.2 m) ft (305 mm) ft (1.2 m) ft (305 mm) ft (1.2 m) ft (305 mm) ft (1.2 m) x 60 Beam Angle 1 ft (305 mm) ft (1.2 m) ft (305 mm) ft (1.2 m) ft (305 mm) ft (1.2 m) ft (305 mm) ft (1.2 m) ft (305 mm) ft (1.2 m) Accessories Use Item Number when ordering in North America. Item Type Size Item Number Philips 12NC Leader Cable Jumper Cable UL / cul ft (15.2 m) CE End-to-End UL / cul 1 ft (305 mm) ft (1.5 m) End-to-End CE 1 ft (305 mm) ft (1.5 m) ft (305 mm) Glare Shield 2 ft (610 mm) ft (914 mm) ft (1.2 m) Additional Terminators Quantity Additional Hinges Quantity Use Item Number when ordering in North America. 4 Product Guide

5 Installation offers dimmable, high-quality solid color LED illumination for surface grazing and wall-washing applications, both indoors and outdoors. Patented Powercore technology integrates LED power and data management within the fixtures and eases installation by eliminating the need for external power supplies. E Refer to the ew / ecolor Graze Powercore Installation Instructions for specific warning and caution statements. Owner / User Responsibilities It is the responsibility of the contractor, installer, purchaser, owner, and user to install, maintain, and operate fixtures in such a manner as to comply with all applicable codes, state and local laws, ordinances, and regulations. Consult with the appropriate electrical inspector to ensure compliance. Installing in Damp or Wet Locations When installing in damp or wet locations, seal all fixtures and all junction boxes with electronics-grade RTV silicone sealant so that water or moisture cannot enter or accumulate in wiring compartments, cables, fixtures, or other electrical parts. Use suitable outdoor-rated junction boxes when installing in damp or wet locations. Additionally, use gaskets, clamps, and other parts required for installation to comply with all applicable local and national codes. Fixture run lengths 110 VAC 120 VAC 220 VAC 240 VAC assuming 1 ft (305 mm) fixtures installed end-to-end on a 20 A circuit, using a standard 50 ft (15.2 m) Leader Cable E For help calculating the number of fixtures your specific installation can support, download the Configuration Calculator from or consult Application Engineering Services at support@colorkinetics.com. Planning Your Installation Regardless of the size and complexity of your installation, the time you spend planning can help minimize installation and configuration issues later. Well-designed lighting brightens an area, highlights architectural features or products, and enhances the ways you perform tasks. Keep the following in mind as you plan your installation: Refer to the lighting design plan, architectural diagram, or other diagram that shows the physical layout of the installation to identify the locations of all switches, fixtures, and cables. fixtures can be installed in series or in parallel (wired to a common junction box).the maximum number of fixtures each circuit can support depends on specific configuration details such as fixture length, fixture spacing, circuit size, line voltage, and leader cable length. As an example, the table to the left lists the maximum number of fixtures in a single run at various voltages, assuming 1 ft (305 mm) fixtures installed end-to-end on a 20 A circuit, using a standard 50 ft (15.2 m) Leader Cable. Keep in mind that these figures, provided as a guideline, are accurate for the specified configuration only. Changing the configuration can affect the fixture run lengths. Conduit fixtures can be connected in a run using the fixtures 6 ft (1.2 m) 3-conductor flying leads and junction boxes. Ensure that all junction boxes are suitable for the environment and sealed if necessary, and that all wiring between junction boxes complies with local codes. For high-contrast surface grazing for example, to highlight unique textures or features place 10º x 60º fixtures within 4 in (102 mm) of a wall or other surface, with each fixture s light beam parallel with the wall or surface. For smooth, wall-washing light that reflects a glare-free ambient glow into the surrounding area, use 30º x 60º fixtures, and place them at a greater distance from the wall or surface, with each fixture projecting its light beam parallel or at an angle with the wall or surface. All fixtures offer a 60º horizontal beam angle. The 60º beam angle lets you add space between fixtures without visible light scalloping. Product Guide 5

6 Assemble Additional Parts and Tools Ensure that all additional parts and tools are available, including: The included mounting hinges and hardware 2 mm, 2.5 mm, and 4 mm hex key wrenches 1/4 in (5 mm) socket cap fasteners, anchors, or screws for surface mounting Conduit as needed 3-conductor copper wire, as needed. Standard 12 AWG (2.05 mm) stranded wire is recommended. Junction boxes, as needed, rated for your application. (Refer to the manufacturer s literature for additional items required for mounting or sealing.) Electronics-grade room temperature vulcanizing (RTV) silicone sealant, as needed E Clean the lens with water and mild detergent using a soft cleaning cloth, and wipe dry. Because they will scratch, soften, pit, haze, yellow, mar, or crack the lens, do not use paper towels, abrasive cleaning products, window cleaners, or cleaning solutions containing chemicals such as ammonia, sodium hydroxide, and isopropyl alcohol. Included in the box fixture (1) or (2) Mounting hinges (2) or (4) M5, 15 mm stainless steel hex bolts for hinge installation Installation Instructions Mount and Connect Fixtures Make sure the power is OFF before mounting and connecting ecolor Graze Powercore fixtures. Standard fixtures offer bulkhead connectors that accept the pre-configured Leader and Jumper Cables. Because they have a male connector on one end of the fixture and a female connector on the other end, fixtures are directional, and must all be oriented in the same direction. Use Conduit in installations where local electrical codes require you to run conduit to the fixtures. Conduit fixtures have threaded openings that accept 1/2 in NPT conduit. Because both ends are the same, Conduit fixtures can be oriented in either direction. Mount Fixtures 1. Using the included 4 mm hex hardware, attach two hinges to each fixture. There are three possible methods for attaching hinges to the fixtures, each method offering differing degrees of swing radius and space-efficiency. Select the method most suitable for your application in (100 mm) Swing radius 3.62 in (92 mm) Swing radius 1.16 in (29 mm) 1.16 in (29 mm) in (85 mm) Swing radius 2. If installing Conduit fixtures, or ecolor Graze Powercore fixtures in parallel, mount junction boxes in accordance with the lighting design plan. 6 Product Guide

7 Conduit fixtures require a junction box to make connections between each pair of fixtures in a series. Each end of the fixture has integrated 6 ft (1.8 m) flying leads on each end for junction box connections. 3. When installing a linear series of ecolor Powercore fixtures, make sure that all fixtures are oriented in the same direction. The Leader Cable connects to the male bulkhead connector on the first fixture in each series. fixtures Leader Cable 50 ft (15.2 m) To line voltage Terminator Jumper Cable 1 ft (305 m) or 5 ft (1.5 m) Jumper Cable End-to-End C Because both ends of the fixture are the same, Conduit fixtures can be oriented in either direction. Conduit fixtures To line voltage Minimum distance between fixtures Junction box for termination Junction box for connecting 6 ft (1.8 m) fixture flying leads Junction box for connecting 6 ft (1.8 m) fixture flying leads Fixture flying leads.125 in (3 mm) Minimum Using 1/4 in (5 mm) socket cap screws, bolts, or anchors, mount the fixtures with hinge assemblies directly to a wall or other mounting surface. Make sure the mounting surface is flat, suitable for the mounting hardware, and clear of debris and other obstructions. 4. Rotate the fixture hinge assemblies into the desired positions. For consistent position control, use the indicators on the side of each hinge knuckle for reference. Use a 2 mm hex key wrench to loosen the set screws, as needed. 5. To accommodate installation from various angles, each hinge has four set screws designed to lock the hinge position. All four, or only two, of the set screws may be used, depending on the mounting method and swing radius you select for the hinge. For example, if the hinge leaves are to be fully closed, the interior set screws may not be accessible. Do not lock the hinge position at this time; the hinges have a built-in constant torque feature that allows temporary positioning. For optimal light output performance, aim and lock the hinges after mounting fixtures. Product Guide 7

8 Make Cable Connections () 1. If installing fixtures in series, run a 50 ft (15.2 m) Leader Cable from a line voltage source to the first fixture in the series. Twist the connector ends to lock the Leader Cable into place. 2. If installing fixtures in parallel, run 3-conductor copper wire from a line voltage source to a common junction box. Run 50 ft (15.2 m) Leader Cables from the common junction box to the first fixture in each series. Twist the connector ends to lock the Leader Cables into place. Within the common junction box, use wire nuts to connect line, neutral, ground, and data wires. Tuck wire connections into the junction box. Secure all junction box covers. If installing in a damp or wet location, seal all junction boxes and points of entry with contractor-grade RTV silicone sealant. Use gaskets, clamps, and other parts and fittings required to comply with local outdoor wiring codes. 3. Connect all Jumper Cables between fixtures. Twist the connector ends to lock. 4. Attach the terminator to the last fixture in each series. Terminators are provided with the Leader Cables. Leader Cable Connector Dimensions UL / cul 14 AWG.07 in (1.85 mm) CE 12 AWG.08 in (2 mm).37 in (9.3 mm).45 in (11.4 mm) 1.88 in (48 mm) 1.88 in (48 mm).91 in (23 mm).91 in (23 mm) 8 Product Guide

9 Make Cable Connections ( Conduit) 1. If installing fixtures in series, run 1/2 in NPT conduit and 3-conductor copper wire from a line voltage source to the first fixture in the series. Use wire nuts to connect line, neutral, ground, and data wires to the fixture s flying leads. 2. If installing fixtures in parallel, run 1/2 in NPT conduit and 3-conductor copper wire from a line voltage source to a common junction box. Run the integrated 6 ft (1.2 m) 3-conductor flying leads and 1/2 in NPT conduit from the first fixture in each series to the common junction box. Within the common junction box, use wire nuts to connect line, neutral, ground, and data wires. Tuck wire connections into the junction box. 3. To make connections between Conduit fixtures in a series, run the integrated 6 ft (1.2 m) 3-conductor flying leads and 1/2 in NPT conduit from the output end of one fixture and input end of the next fixture in the series to a junction box. Within the junction boxes, use wire nuts to connect line, neutral, ground, and data wires. Tuck wire connections into the junction box. 4. Terminate the run by running 1/2 in NPT conduit and the flying leads from the output end of the last Conduit fixture in the series to a junction box. Within the junction box, use wire nuts to connect line, neutral, ground, and data wires. Tuck wire connections into the junction box. 5. Secure all junction box covers. If installing in a damp or wet location, seal all junction boxes and points of entry with contractor-grade RTV silicone sealant. Use gaskets, clamps, and other parts and fittings required to comply with local outdoor wiring codes. Product Guide 9

10 Make Power Connections Once you ve made all fixture and junction box connections, connect the flying leads from a Leader Cable, 3-conductor wire from a common junction box, or the cable from the input end of the first Conduit fixture in a series to the fixture cable to a line circuit by a method that meets all national, regional, and local regulations. E To ensure CE compliance when using a terminal block, the terminal block must conform to EN or EN and meet the specified ratings for the voltage listed in this Product Guide. G N L UL / cul G N L CE 50 ft ( 5.24 m) ( ) 50 ft ( 5.24 m) ( ) Aim and Lock the Fixtures Make sure the power is ON before aiming and locking fixtures. Rotate the fixtures to achieve the optimal angle for light output. For consistent position control, use the indicators on the side of each hinge knuckle as reference. Once satisfied with fixture angles and positioning, use a 2 mm hex key wrench to tighten the hinge position set screws and lock each hinge Product Guide

11 E Do not look directly into beam when aiming and locking. E The hinge position set screws have factory applied thread lock. Confirm the fixture angle and positioning before locking each hinge. Attach Glare Shields (Optional) Glare Shields, in 1 ft (305 mm), 2 ft (610 mm), 3 ft (914 mm), and 4 ft (1.2 m) lengths, can be inserted in the grooves in the housing. Glare Shields block unwanted spill light, and can shield the fixture s LEDs from being directly visible in certain mounting situations. 1. Insert the Glare Shield s triangular tab in the outer groove on the side of the housing. 2. Using a hex wrench, tighten the locking screws to hold the Glare Shield in place. 1.5 mm 3. (Optional) Attach a tether to the knockout in the Glare Shield and affix the tether to a secure anchor point. Product Guide 11

12 Philips Color Kinetics 3 Burlington Woods Drive Burlington, Massachusetts USA Tel Tel Fax Copyright 2011 Philips Solid-State Lighting Solutions, Inc. All rights reserved. Chromacore, Chromasic, CK, the CK logo, Color Kinetics, the Color Kinetics logo, ColorBlast, ColorBlaze, ColorBurst, ew Fuse, ColorGraze, ColorPlay, ColorReach, iw Reach, ew Reach, DIMand, EssentialWhite, ew, icolor, icolor Cove, IntelliWhite, iw, iplayer, Optibin, and Powercore are either registered trademarks or trademarks of Philips Solid-State Lighting Solutions, Inc. in the United States and / or other countries. All other brand or product names are trademarks or registered trademarks of their respective owners. Due to continuous improvements and innovations, specifications may change without notice. DAS R

Vaya Linear LP, White & Mono

Vaya Linear LP, White & Mono Vaya Linear LP, White & Mono Vaya Linear LP White & Mono is a reliable and cost effective LED lighting fixture designed for static white or mono colored lighting effects. Vaya Linear LP is ideal for exterior

More information

LED IMPORTANT SAFETY INSTRUCTIONS

LED IMPORTANT SAFETY INSTRUCTIONS LED IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION To reduce the risk of death, personal injury or property damage

More information

HPNLS-LO. Installation Manual

HPNLS-LO. Installation Manual Installation Manual WARNING: DO NOT LIFT FIXTURE BY CABLES. Do not attempt to install or use the fixture without reading the installation instructions and safety labels completely. This could result in

More information

LED IMPORTANT SAFETY INSTRUCTIONS

LED IMPORTANT SAFETY INSTRUCTIONS LED IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION To reduce the risk of death, personal injury or property damage

More information

New Linear Series DISCONTINUED

New Linear Series DISCONTINUED OVERVIEW / SPECIFICATION EcoSpec Linear INT Warm Cove - is designed with a slim profile and integral brackets with 180 vertical rotation adjustability. Warm Cove Series color temperatures of 2300K and

More information

Type 2 Models. Owner s Guide and Installation Manual. English Español

Type 2 Models. Owner s Guide and Installation Manual. English Español For Your Records and Warranty Assistance For reference, also attach your receipt or a copy of your receipt to the manual. Model Name Type 2 Models Owner s Guide and Installation Manual Model No. Date Purchased

More information

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels Installation Instructions For the 18 Built-In Dishwasher and Front Color Panels Printed in USA 154232102 Before You Begin DO NOT INSTALL DISHWASHER UNTIL YOU HAVE READ ALL INSTRUCTIONS. FOR YOUR SAFETY,

More information

Installation and Operation Manual CLEARVIEW DAY COVER CAUTION: To view a video scan the QR code above

Installation and Operation Manual CLEARVIEW DAY COVER CAUTION: To view a video scan the QR code above Installation and Operation Manual CLEARVIEW DAY COVER To view a video scan the QR code above CAUTION: Please read this manual completely before attempting to install, operate or service this equipment

More information

WPLED 26W INSTALLATION INSTRUCTIONS

WPLED 26W INSTALLATION INSTRUCTIONS WPLED 26W INSTALLATION INSTRUCTIONS Thank you for buying RAB lighting fixtures. Our goal is to design the best quality products to get the job done right. We d like to hear your comments. Call the Marketing

More information

52 CEILING FAN READ AND SAVE THESE INSTRUCTIONS FAN RATING AC 120V.

52 CEILING FAN READ AND SAVE THESE INSTRUCTIONS FAN RATING AC 120V. Irene 52 CEILING FAN READ AND SAVE THESE INSTRUCTIONS FAN RATING AC 120V. 60Hz TABLE OF CONTENTS Tools and Materials Required... 1 Package Contents... 1 Safety Rules... 2 Mounting Options... 3 Hanging

More information

MODELS SafeSite LED Linear, Class I Div. 1 2 & 4 Versions

MODELS SafeSite LED Linear, Class I Div. 1 2 & 4 Versions INSTALLATION AND MAINTENANCE MANUAL SAFESITE LED LINEAR FIXTURE Document No: 9100-127-1402-99 Rev K December, 2016 MODELS SafeSite LED Linear, Class I Div. 1 2 & 4 Versions SUITABLE FOR WET LOCATIONS in

More information

installation and operation manual for Hunter Ceiling Fans

installation and operation manual for Hunter Ceiling Fans For Your Records and Warranty Assistance Model Name: Catalog/Model No.: Serial No.: Date Purchased: Where Purchased: For reference also attach your receipt or a copy of your receipt to the manual. installation

More information

Owner s Guide and Installation Manual

Owner s Guide and Installation Manual For Your Records and Warranty Assistance For reference, also attach your receipt or a copy of your receipt to the manual. Model Name Type 3 Models Owner s Guide and Installation Manual Model No. Date Purchased

More information

Install the Fixture using a Stake (Pathway Models Only) Prepare the Fixture. Pathway and Bollards INSTALLATION OPTIONS: Installation Instructions for

Install the Fixture using a Stake (Pathway Models Only) Prepare the Fixture. Pathway and Bollards INSTALLATION OPTIONS: Installation Instructions for Installation Instructions for Pathway and Bollards 920OA_OB. OUTDOOR GENERAL PRODUCT I NFORMATION: This product is suitable for wet locations. Pathway models are 2VAC input only. Refer to product specsheet

More information

Fillmore Small Pendant Assembly and Installation Instructions

Fillmore Small Pendant Assembly and Installation Instructions CAUTION: Fillmore Small Pendant Assembly and Installation Instructions BEFORE INSTALLING FIXTURE, MAKE SURE THE POWER TO THE CIRCUIT IS TURNED OFF AT THE MAIN FUSE BOX / CIRCUIT BREAKER UTILITY BOX. Important

More information

Product Code for Zoom: KPLZML1RGBW Product Code for Wall Wash: KPLWWL2RGBW

Product Code for Zoom: KPLZML1RGBW Product Code for Wall Wash: KPLWWL2RGBW COD: 2BP8CS00 KEPLERO RGBW,167$//$7,21 *8,'( Product Code for Zoom: KPLZML1RGBW Product Code for Wall Wash: KPLWWL2RGBW :$51,1* To ensure a maximum efficient use of the product, read the instructions before

More information

Fluid Round Large 700 FMFLDRL_

Fluid Round Large 700 FMFLDRL_ Installation Instructions for Fluid Round Large 700 FMFLDRL_ 90FLUIDRL.0 CEILING COLLECTION GENERAL PRODUCT I NFORMATION: This product can mount to either a " square electrical box with round plaster ring

More information

C-IV 60 CEILING FAN READ AND SAVE THESE INSTRUCTIONS. FAN RATING AC 120V. 60Hz

C-IV 60 CEILING FAN READ AND SAVE THESE INSTRUCTIONS. FAN RATING AC 120V. 60Hz C-IV 60 CEILING FAN READ AND SAVE THESE INSTRUCTIONS FAN RATING AC 120V. 60Hz Please do not use any electric or battery powered tools in the assembly and installation of this or any Matthews Fan Company

More information

STOP RESIN TUB WITH INTEGRAL DRAIN PLANNING BEFORE YOU BEGIN TOOLS AND MATERIALS: GETTING STARTED INSTALLATION INSTRUCTIONS.

STOP RESIN TUB WITH INTEGRAL DRAIN PLANNING BEFORE YOU BEGIN TOOLS AND MATERIALS: GETTING STARTED INSTALLATION INSTRUCTIONS. BEFORE YOU BEGIN We recommend consulting a professional if you are unfamiliar with installing bathroom fixtures and plumbing. Signature Hardware accepts no liability for any damage to the floor, walls,

More information

INSTALLATION INSTRUCTION In-Ground

INSTALLATION INSTRUCTION In-Ground SAFETY INSTRUCTION IMPORTANT: NEVER attempt any work without shutting off the electricity. Read all instructions before installing. System is intended for installation by a qualified electrician in accordance

More information

Installation Instructions 30 French Door Built-in Wall Ovens

Installation Instructions 30 French Door Built-in Wall Ovens Installation Instructions 30 French Door Built-in Wall Ovens Questions? Call 1.800.GE.CARES (1.800.432.2737) or visit www.geappliances.com In Canada, call 1.800.561.3344 or visit www.geappliances.ca DESIGN

More information

! WARNING. Before using product, read and understand instructions.

! WARNING. Before using product, read and understand instructions. McDonnell & Miller Installation & Maintenance Instructions MM-273A Manual eset Applications: Conductance type control for steam boilers when a manual reset high water alarm or cut-off is required. 5-1/2"

More information

Cold Deck Canopy and Shelf Lights and Retrofit Kit

Cold Deck Canopy and Shelf Lights and Retrofit Kit PAGE 1 OF 8 General Information Cold Deck LED lighting systems are intended for use inside of commercial refrigerated display merchandisers for food zone, splash zone, and non-food zones only. Cold Deck

More information

HPNLS-RT. Installation Manual

HPNLS-RT. Installation Manual Installation Manual WARNING: Do not lift fixture by cables. This could result in permanent damage to both the fixture and the cables. Damage resulting from grasping cables and/or putting undue pressure

More information

Owner s Guide and Installation Manual

Owner s Guide and Installation Manual For Your Records and Warranty Assistance For reference, also attach your receipt or a copy of your receipt to the manual. Model Name Type 2A Models Owner s Guide and Installation Manual Model No. Date

More information

INSTALLATION INSTRUCTIONS ELECTRIC DRYER

INSTALLATION INSTRUCTIONS ELECTRIC DRYER INSTALLATION INSTRUCTIONS ELECTRIC DRYER Table of Contents... 2 IMPORTANT: Save for local electrical inspector s use. 3397627C DRYER SAFETY... 2 INSTALLATION INSTRUCTIONS... 4 Tools and Parts... 4 Location

More information

MODEL LP3 INSTALLATION AND SERVICE INSTRUCTIONS FOR STREAMLINE LP3 STROBE LIGHTS

MODEL LP3 INSTALLATION AND SERVICE INSTRUCTIONS FOR STREAMLINE LP3 STROBE LIGHTS Specifications subject to change without notice. USA 150303 Page 1 of 10 MODEL LP3 INSTALLATION AND SERVICE INSTRUCTIONS FOR STREAMLINE LP3 STROBE LIGHTS Specifications subject to change without notice.

More information

Orrin. Instruction Manual. Includes our new CoolTouch TM Control System Looks permanent, but goes wherever you go! U.S.

Orrin. Instruction Manual. Includes our new CoolTouch TM Control System Looks permanent, but goes wherever you go! U.S. Includes our new CoolTouch TM Control System Looks permanent, but goes wherever you go! U.S. Patent Pending Orrin A Kichler Select ceiling fan Kichler Lighting 7711 East Pleasant Valley Road P.O. Box 318010

More information

GLED INSTALLATION INSTRUCTIONS

GLED INSTALLATION INSTRUCTIONS GLED INSTALLATION INSTRUCTIONS TM Fixtures must be wired in accordance with the National Electrical Code and all applicable local codes. Proper grounding is required for safety. THIS PRODUCT MUST BE INSTALLED

More information

SPECTRE BY. D778,422; D779,052; D779,093; D792,577; Add'l U.S. Patent(s) Pending INSTRUCTION MANUAL WARRANTY CERTIFICATE

SPECTRE BY. D778,422; D779,052; D779,093; D792,577; Add'l U.S. Patent(s) Pending INSTRUCTION MANUAL WARRANTY CERTIFICATE SPECTRE BY D778,422; D779,052; D779,093; D792,577; Add'l U.S. Patent(s) Pending INSTRUCTION MANUAL WARRANTY CERTIFICATE This product is protected by United States Federal and/or State Law including Patents,

More information

ST. KITTS CEILING FAN

ST. KITTS CEILING FAN ITEM #0845047 ST. KITTS CEILING FAN MODEL #40829 Questions, problems or missing parts? Before returning this item to your retailer, call our customer service department at 1-800-643-0067, Monday - Thursday,

More information

HighLINER 2. General Information: FOR YOUR SAFETY. Installation Guide for C1I75, L1C1I75, C2I75, L135C2I75

HighLINER 2. General Information: FOR YOUR SAFETY. Installation Guide for C1I75, L1C1I75, C2I75, L135C2I75 General Information: is intended for linear lighting in storerooms, walk-in coolers, indoor and outdoor soffits, outdoor canopies, car washes, and a variety of other lighting applications. Do not mount

More information

ALUMA INSTRUCTION MANUAL WARRANTY CERTIFICATE

ALUMA INSTRUCTION MANUAL WARRANTY CERTIFICATE ALUMA BY INSTRUCTION MANUAL WARRANTY CERTIFICATE Manual design and all elements of manual design are protected by U.S. Federal and/or State Law, including Patent, Trademark and/or Copyright laws. The Minka-Aire

More information

VACUUM VALVES AND HOSES

VACUUM VALVES AND HOSES VACUUM VALVES AND HOSES 5046 Vacuum Valve Two-piece 500 F (260 C) industry standard 5255 Vacuum Valve Three-piece 500 F (260 C) industry standard SS5700 Stainless Steel Vacuum Valve Three-piece 1000 F

More information

Linear Lighting Pro Dimmable Series XLAV80. Constant Voltage Dimmable LED Driver. Features. Model Selection Key 80-BCV-D

Linear Lighting Pro Dimmable Series XLAV80. Constant Voltage Dimmable LED Driver. Features. Model Selection Key 80-BCV-D Linear Lighting Pro Dimmable Series XLAV XLAV Constant Voltage Dimmable LED Driver Model Selection Key XLAV(A) -BCV-D SI: Waterproof standard aluminum housing SSB: Aluminum housing with easy install wiring

More information

Retrofit Instructions CLEARVIEW DAY COVER CAUTION: Please read this manual completely before attempting to install, operate or service this equipment

Retrofit Instructions CLEARVIEW DAY COVER CAUTION: Please read this manual completely before attempting to install, operate or service this equipment Retrofit Instructions CLEARVIEW DAY COVER CAUTION: Please read this manual completely before attempting to install, operate or service this equipment This manual is Copyright 2019 Duke Manufacturing Co.

More information

LED IMPORTANT SAFETY INSTRUCTIONS

LED IMPORTANT SAFETY INSTRUCTIONS LED IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION To reduce the risk of death, personal injury or property damage

More information

DISHWASHER. Models DW2432 and DW2432SS. Installation Manual. Write Serial Number (on inner door of unit) here:

DISHWASHER. Models DW2432 and DW2432SS. Installation Manual. Write Serial Number (on inner door of unit) here: DISHWASHER Models DW2432 and DW2432SS Installation Manual Write Serial Number (on inner door of unit) here: Felix Storch, Inc. Summit Appliance Division 770 Garrison Avenue Bronx, New York 10474 www.summitappliance.com

More information

POINT ROLLOVER LIGHTS PRL LED HELIDECK SEMIFLUSH LIGHT

POINT ROLLOVER LIGHTS PRL LED HELIDECK SEMIFLUSH LIGHT Compliances: ETL Listed to UL 98 & UL 98A Marine Vessels USA CSA C22.2 No..-4 Canada FAA AC /39-2B Heliport Design Guide ICAO Annex 14, Volume II UK CAA CAP 437, Chapter 4, paragraph 3.1 IMO 9 MODU Code

More information

Juna Ceiling Fan JU54. Installation Instructions Instrucciones de instalación Instructions d installation

Juna Ceiling Fan JU54. Installation Instructions Instrucciones de instalación Instructions d installation Juna Ceiling Fan JU54 Installation Instructions Instrucciones de instalación Instructions d installation Read and Save These Safety Precautions. Turn off electricity at main switch before wiring or servicing

More information

52 Lacey LED. Instruction Manual. 6 Speed DC Wall Control System

52 Lacey LED. Instruction Manual. 6 Speed DC Wall Control System 6 Speed DC Wall Control System 52 Lacey LED HIGH EFFICIENCY DC MOTOR Kichler Lighting 7711 East Pleasant Valley Road P.O. Box 318010 Cleveland, Ohio 44131-8010 Customer Service 866.558.5706 8:30 AM to

More information

DAGNY LK. Ceiling Mounted Rotational Fan READ AND SAVE THESE INSTRUCTIONS. FAN RATING AC 110V~60Hz

DAGNY LK. Ceiling Mounted Rotational Fan READ AND SAVE THESE INSTRUCTIONS. FAN RATING AC 110V~60Hz DAGNY LK Ceiling Mounted Rotational Fan READ AND SAVE THESE INSTRUCTIONS FAN RATING AC 110V~60Hz Please do not use any electric or battery powered tools in the assembly and installation of this or any

More information

Owner s Guide and Installation Manual

Owner s Guide and Installation Manual For Your Records and Warranty Assistance For reference, also attach your receipt or a copy of your receipt to the manual. Model Name Type 2 Models Owner s Guide and Installation Manual Model No. Catalog

More information

Moon Visions Lighting

Moon Visions Lighting Moon Visions Lighting 2018-2019 Product Guide Quality lighting since 2008 214.393.7407 www.moonvisionslighting.com New Light Bar Series! UL Listed under UL Standard 1598 Certified to CSA Standard 1668

More information

GROTON. U.S. Patent(s) Pending INSTRUCTION MANUAL WARRANTY CERTIFICATE

GROTON. U.S. Patent(s) Pending INSTRUCTION MANUAL WARRANTY CERTIFICATE GROTON BY U.S. Patent(s) Pending INSTRUCTION MANUAL WARRANTY CERTIFICATE This product is protected by United States Federal and/or State Law, including Patent, Trademark and/or Copyright laws. Manual design

More information

FitchTM. Instruction Manual. Includes our Basic Function CoolTouch TM Control System Looks permanent, but goes wherever you go!

FitchTM. Instruction Manual. Includes our Basic Function CoolTouch TM Control System Looks permanent, but goes wherever you go! Includes our Basic Function CoolTouch TM Control System Looks permanent, but goes wherever you go! FitchTM A Kichler Décor ceiling fan U.S. Patent Pending Kichler Lighting 7711 East Pleasant Valley Road

More information

Table of Contents. What to Expect with. Tools Needed. Mounting Options. Blades

Table of Contents.   What to Expect with. Tools Needed. Mounting Options. Blades Table of Contents 1.888.830.1326 Ceiling Bracket 30 inches Ladder Downrod 3 Wiring 10 Operation, Maintenance & Cleaning Light Kit 11 Troubleshooting??? 17 15 1 13 5 Blades 9 Switch Housing 12 Canopy 6

More information

Cold Deck FIT. Canopy and Shelf Lights and Retrofit Kit. Installation Guide for General Information. Tools and Accessories Recommended

Cold Deck FIT. Canopy and Shelf Lights and Retrofit Kit. Installation Guide for General Information. Tools and Accessories Recommended General Information Cold Deck FIT LED lighting systems are intended for use inside of commercial refrigerated display merchandisers for food zone, splash zone, and non-food zones only. Cold Deck FIT LED

More information

Owner s Guide and Installation Manual

Owner s Guide and Installation Manual For Your Records and Warranty Assistance For reference, also attach your receipt or a copy of your receipt to the manual. Model Name Type 2A Models Owner s Guide and Installation Manual Model No. Date

More information

Electrical cable Water supply tube Fittings for tube Coupler Teflon tape. Hole saw min. 2½" bit

Electrical cable Water supply tube Fittings for tube Coupler Teflon tape. Hole saw min. 2½ bit Installation Parts and Tools Parts not Provided Electrical cable Water supply tube Fittings for tube Coupler Teflon tape Air gap Wire nuts for 6-gauge wiring Hose clamp ⅞" UL approved strain relief Electrical

More information

Band Heaters W A T L O W. Special Mica Barrel and Nozzle

Band Heaters W A T L O W. Special Mica Barrel and Nozzle W A T L O W For over 80 years, Watlow has been solving complex and unique application problems with standard mica barrel and nozzle heaters. Watlow is continuously improving design and application knowledge

More information

Installation Instructions

Installation Instructions Installation Instructions For the 18" Built-In Dishwasher Sears, Roebuck and Co. Sears Canada, Inc. Hoffman Estates, IL 60179 U.S.A. Toronto, Ontario, Canada M5B 2B8 154435201 Before You Begin DO NOT INSTALL

More information

SOLID STATE ILLUMINATED RAIL

SOLID STATE ILLUMINATED RAIL SOLID STATE ILLUMINATED RAIL Grand Park, Los Angeles California Lighting Design: The Lighting Design Alliance Installation: Rosendin Electric Manufacturer Representative: Performance Lighting Systems

More information

Hatteras BayTM. Patio. Instruction Manual. Includes our new CoolTouch TM Control System Looks permanent, but goes wherever you go! U.S.

Hatteras BayTM. Patio. Instruction Manual. Includes our new CoolTouch TM Control System Looks permanent, but goes wherever you go! U.S. Hatteras BayTM Patio A Kichler Décor ceiling fan Designed to coordinate with a popular Kichler Lighting collection. Includes our new CoolTouch TM Control System Looks permanent, but goes wherever you go!

More information

ITEM # , , PAWTUCKET CEILING FAN MODEL #40958, 40959, 40047

ITEM # , , PAWTUCKET CEILING FAN MODEL #40958, 40959, 40047 ITEM #0803775, 0721899, 0807427 PAWTUCKET CEILING FAN MODEL #40958, 40959, 40047 Harbor Breeze is a registered trademark of LF, LLC. All Rights Reserved. Español p. 20 ATTACH YOUR RECEIPT HERE Serial Number

More information

CALIBER LIGHTING. SERIES 4VDWWL Shower Lens LED Dim-to-Warm Recessed Downlight, 1018 Lumen APPLICATION PRODUCT DATA. 4VLEDWL Example: 4VLEDWLSCLPF

CALIBER LIGHTING. SERIES 4VDWWL Shower Lens LED Dim-to-Warm Recessed Downlight, 1018 Lumen APPLICATION PRODUCT DATA. 4VLEDWL Example: 4VLEDWLSCLPF APPLICATION Small aperture medium distribution downlight is suitable for applications that require a dim-to-warm long life LED lamp source and a lensed wet location reflector. PRODUCT DATA LED MODULE:

More information

Installation Instructions Part No

Installation Instructions Part No Model PS301SS00 Professional Series Refrigerated, Internet Controlled 30 Electric Built-In Single Wall Oven Installation Instructions Part No. 101768 2 3 3 4 5 6 7-13 14 14 14 Before You Start Electrical

More information

TOUCHDOWN 48 CEILING FAN

TOUCHDOWN 48 CEILING FAN TOUCHDOWN 48 CEILING FAN MODEL #50205 Español p. 20 Questions, problems, missing parts? Before returning to your retailer, call our customer service department at 1-877-361-3883, Monday - Thursday, 8 am

More information

EcoBrite Smooth Light LED Light Fixtures

EcoBrite Smooth Light LED Light Fixtures Installation Guide EcoBrite Smooth Light LED Light Fixtures BEFORE YOU BEGIN INSTALLATION Read these instructions carefully. Failure to follow these instructions will invalidate the warranty on this product

More information

WAILEA OWNER S MANUAL

WAILEA OWNER S MANUAL WAILEA OWNER S MANUAL The blades in each pack are matched for equal weight to assure smooth fan operation. If more than one fan is being installed, be careful not to mix blades from different cartons.

More information

ALUMA INSTRUCTION MANUAL WARRANTY CERTIFICATE

ALUMA INSTRUCTION MANUAL WARRANTY CERTIFICATE ALUMA BY INSTRUCTION MANUAL WARRANTY CERTIFICATE Manual design and all elements of manual design are protected by U.S. Federal and/or State Law, including Patent, Trademark and/or Copyright laws. Minka-Aire

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Flow Lighting QuickLED NEW FIXTURE 2x4 2x2 1x4 Corporate 1240 Texan Trail, Suite 102 Grapevine, TX 76051 (817)435-8484 Office www.flowledlighting.com READ AND FOLLOW ALL SAFETY

More information

AFTER INSTALLATION DELIVER THIS MANUAL TO OWNER IMPORTANT SAFETY INSTRUCTIONS

AFTER INSTALLATION DELIVER THIS MANUAL TO OWNER IMPORTANT SAFETY INSTRUCTIONS Petrolux III Low Profile Wet & Hazardous Location Luminaires AFTER INSTALLATION DELIVER THIS MANUAL TO OWNER 2. INSTALLATION Installation and Maintenance Manual IMPORTANT SAFETY INSTRUCTIONS Figure 1 WARNING

More information

OCH-SS series Direct Wired Units Indoor * and Outdoor Comfort Heaters

OCH-SS series Direct Wired Units Indoor * and Outdoor Comfort Heaters 1200 North Main Street Fostoria, OH 44830 Phone: 800-495-4525 Fax: 419-435-0842 A DIVISION OF www.fostoriaindustries.com OCH-SS series Direct Wired Units Indoor * and Outdoor Comfort Heaters *EXCLUDING

More information

GelCap SL. GelCap SL splice cover kits quickly and con-veniently insulate, seal, and protect stub splice connections up to 1000 volts.

GelCap SL. GelCap SL splice cover kits quickly and con-veniently insulate, seal, and protect stub splice connections up to 1000 volts. Cold-Applied Splices GelCap SL Stub splice cover kit with connector for use with street lighting (1000 V) 34 Tyco Electronics GelCap SL splice cover kits provide quick installation, dependable performance,

More information

Damp Locations Wall & Ceiling Mount BEFORE YOU BEGIN

Damp Locations Wall & Ceiling Mount BEFORE YOU BEGIN INSTALLATION AND ASSEMBLY INSTRUCTIONS LXLW LED SERIES Damp Locations Wall & Ceiling Mount SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION BEFORE YOU BEGIN Read these instructions completely

More information

Standard Downrod for ceilings 8-10 feet high. Longer Downrod for ceilings 10 feet or higher

Standard Downrod for ceilings 8-10 feet high. Longer Downrod for ceilings 10 feet or higher Table of Contents www.casablancafanco.com To register your fan, please visit: www.casablancafanco.com/register What to Expect with Your Installation Save your receipt for proof of purchase. Ceiling Bracket??

More information

CXB Series SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. LED Luminaire TO INSTALL: INSTALLATION INSTRUCTIONS INSTRUCTIONS D INSTALLATION

CXB Series SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. LED Luminaire TO INSTALL: INSTALLATION INSTRUCTIONS INSTRUCTIONS D INSTALLATION CXB Series LED Luminaire Junction Box, Pendant and Hook and Cord IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed including the following: READ AND

More information

GRANDE OWNER S MANUAL

GRANDE OWNER S MANUAL LE GRANDE OWNER S MANUAL The blades in each pack are matched for equal weight to assure smooth fan operation. If more than one fan is being installed, be careful not to mix blades from different cartons.

More information

DESIGN CLASS FUNCTION

DESIGN CLASS FUNCTION PROFESSIONAL QUALITY COOKING EQUIPMENT INSTALLATION MANUAL FOR MEDALLION DUAL FUEL RANGES MODEL NUMBERS: ARR-304DF, ARR-366DF, ARR-364GDDF, ARR-364GRDF, ARR-486GDDF, ARR-486GRDF, ARR-4822GDDF, ARR-484X2GRDF,

More information

CEILING FAN OWNER'S MANUAL

CEILING FAN OWNER'S MANUAL Style that revolves around you. CEILING FAN OWNER'S MANUAL VANTAGE with DC motor 12/14 WARNING: Read and follow these instructions carefully and be mindful of all warnings shown throughout. GENERAL INSTALLATION

More information

C2D1/C1D2 Explosion Proof 50 Watt LED Light Fixture - Paint Spray Booth Approved - 6,250 Lumens

C2D1/C1D2 Explosion Proof 50 Watt LED Light Fixture - Paint Spray Booth Approved - 6,250 Lumens C2D1/C1D2 Explosion Proof 50 Watt LED Light Fixture - Paint Spray Booth Approved - 6,250 Lumens Part #: EPLC2-HB-50LED-RT Page: 1 The Larson Electronics EPLC2-HB-50LED-RT Explosion Proof High Bay light

More information

TraceTek Sensing Module Installation, Operation and Maintenance Instructions DESCRIPTION SPECIFICATIONS APPROVALS TYPE NM

TraceTek Sensing Module Installation, Operation and Maintenance Instructions DESCRIPTION SPECIFICATIONS APPROVALS TYPE NM TTC-1 TraceTek Sensing Module Installation, Operation and Maintenance Instructions DESCRIPTION The nvent RAYCHEM TraceTek TTC-1 sensing module is used with TraceTek sensing cables to detect liquid leaks.

More information

INSTALLATION & OPERATING INSTRUCTIONS

INSTALLATION & OPERATING INSTRUCTIONS INSTALLATION & OPERATING INSTRUCTIONS WARNING RISK OF ELECTRIC SHOCK. CONNECT ONLY TO A CIRCUIT PROTECTED BY A GROUND-FAULT CIRCUIT-INTERRUPTER. THE UNIT SHOULD BE INSTALLED BY A QUALIFIED SERVICE REPRESENTATIVE.

More information

Table of Contents What to Expect with Your Installation. Tools Needed. Wall Control

Table of Contents What to Expect with Your Installation. Tools Needed. Wall Control Table of Contents Congratulations on purchasing your new Casablanca ceiling fan! It will provide comfort and performance in your home or office for many years. This installation and operation manual contains

More information

Owner s Guide and Installation Manual

Owner s Guide and Installation Manual Tribeca Owner s Guide and Installation Manual English Form# M6001-01 20120416 2012 Casablanca Fan Co. Welcome Your new Casablanca ceiling fan is an addition to your home or office that will provide comfort

More information

Innes. Instruction Manual A Kichler Decor ceiling fan. Includes our new TM

Innes. Instruction Manual A Kichler Decor ceiling fan. Includes our new TM Innes 300130 A Kichler Decor ceiling fan Includes our new CoolTouch Control System Looks permanent, but goes wherever you go! U.S. Patent Pending Kichler Lighting 7711 East Pleasant Valley Road P.O. Box

More information

MALIBU STAR OWNER S MANUAL

MALIBU STAR OWNER S MANUAL MALIBU STAR OWNER S MANUAL CONTENTS INTRODUCTION...................................................................... 1 MOUNTING RECOMMENDATIONS..........................................................

More information

CEILING FAN OWNER'S MANUAL

CEILING FAN OWNER'S MANUAL CEILING FAN OWNER'S MANUAL MODEL: Pelham HVFC# 2299 Old Bronze Satin Nickel Polished Nickel READ AND SAVE THESE INSTRUCTIONS FAN RATING AC 120V. 60Hz. CUL LISTED MODEL: AC-554SY05-7S WEIGHT OF THE FAN:

More information

INSTALLATION GUIDE Dual Fuel Ranges

INSTALLATION GUIDE Dual Fuel Ranges INSTALLATION GUIDE Dual Fuel Ranges Contents Wolf Dual Fuel Ranges......................... 3 Safety Instructions............................ 4 Dual Fuel Range Specifications.................. 5 Dual Fuel

More information

GLED INSTALLATION INSTRUCTIONS

GLED INSTALLATION INSTRUCTIONS GLED INSTALLATION INSTRUCTIONS CEILING MOUNTING Mount the fixture to a Junction Box as follows:. 1. Mount the to a 4 junction box or octagonal junction box. Use weatherproof silicone sealant between the

More information

IVR15-RPS O.D. Solid State Illuminated Rail Remote Power Supply

IVR15-RPS O.D. Solid State Illuminated Rail Remote Power Supply IVR15RPS O.D. Solid State Illuminated Rail Remote Power Supply 1.50 recognized 0.3 90 APERTURE Ends of Illuminated rail field cutable to a minimum of 2 1/8 in length. Illuminated rail is available with

More information

INSTALLATION INSTRUCTIONS UNDERCOUNTER DISHWASHERS

INSTALLATION INSTRUCTIONS UNDERCOUNTER DISHWASHERS INSTALLATION INSTRUCTIONS UNDERCOUNTER DISHWASHERS VIKING 111 Front Street Greenwood, Mississippi 38930 USA (662) 455-1200 IMPORTANT - PLEASE READ AND FOLLOW Before beginning - please read these instructions

More information

NATELA 5. Based on 30 PRODUCT SPECIFICATIONS PRODUCT FEATURES PHOTOMETRIC DATA LIGHT DISTANCE CURVE 22W LINEAR WALL WASHER

NATELA 5. Based on 30 PRODUCT SPECIFICATIONS PRODUCT FEATURES PHOTOMETRIC DATA LIGHT DISTANCE CURVE 22W LINEAR WALL WASHER NATELA 5 22W LINEAR WALL WASHER This 22W linear wall washers reveals superior craftsmanship and a slim design, perfect for highlighting building facades and landscape walls (Also Available in RGB). PRODUCT

More information

STACKTM INSTRUCTION MANUAL WARRANTY CERTIFICATE

STACKTM INSTRUCTION MANUAL WARRANTY CERTIFICATE STACKTM INSTRUCTION MANUAL WARRANTY CERTIFICATE 2018 Minka Lighting Inc. Manual design and all elements of manual design are protected by United States Federal and/or State Law including Patents, Trademark,

More information

STOP ACRYLIC TUB WITH INTEGRAL DRAIN PLANNING BEFORE YOU BEGIN TOOLS AND MATERIALS: GETTING STARTED INSTALLATION INSTRUCTIONS.

STOP ACRYLIC TUB WITH INTEGRAL DRAIN PLANNING BEFORE YOU BEGIN TOOLS AND MATERIALS: GETTING STARTED INSTALLATION INSTRUCTIONS. BEFORE YOU BEGIN We recommend consulting a professional if you are unfamiliar with installing bathroom fixtures and plumbing. Signature Hardware accepts no liability for any damage to the floor, walls,

More information

MAYFIELD CEILING FAN LISTED E ITEM # MODEL #BTH44ABZC5C BTH44BNK5C Español p. 20 ATTACH YOUR RECEIPT HERE.

MAYFIELD CEILING FAN LISTED E ITEM # MODEL #BTH44ABZC5C BTH44BNK5C Español p. 20 ATTACH YOUR RECEIPT HERE. Harbor Breeze is a registered trademark of LF, LLC. All Rights Reserved. ITEM #0331094 0331096 MAYFIELD CEILING FAN MODEL #BTH44ABZC5C BTH44BNK5C Español p. 20 ATTACH YOUR RECEIPT HERE Serial Number Purchase

More information

3MAVR60XXD Series Fan. Owner s Guide and Installation Manual. CUL Model NO. : 3MAVR60XXD

3MAVR60XXD Series Fan. Owner s Guide and Installation Manual. CUL Model NO. : 3MAVR60XXD Owner s Guide and Installation Manual 3MAVR60XXD Series Fan CUL Model NO. : 3MAVR60XXD Attach sales receipt to this card and retain as your proof of purchase DATE OF PURCHASE: MODEL NUMBER: RETAILER NAME:

More information

60" Lyndon Patio. Instruction Manual Customer Service :30 AM to 5:00 PM EST, Monday - Friday A Kichler Decor ceiling fan

60 Lyndon Patio. Instruction Manual Customer Service :30 AM to 5:00 PM EST, Monday - Friday A Kichler Decor ceiling fan 60" Lyndon Patio TM 310140 A Kichler Decor ceiling fan Includes wall mount control system Kichler Lighting 7711 East Pleasant Valley Road P.O. Box 318010 Cleveland, Ohio 44131-8010 Instruction Manual Customer

More information

CAST IRON CLAWFOOT TUB

CAST IRON CLAWFOOT TUB BEFORE YOU BEGIN We recommend consulting a professional if you are unfamiliar with installing bathroom fixtures and plumbing. Signature Hardware accepts no liability for any damage to the floor, walls,

More information

AA-480-XX OUTDOOR THERMOELECTRIC COOLER ASSEMBLY USER S MANUAL

AA-480-XX OUTDOOR THERMOELECTRIC COOLER ASSEMBLY USER S MANUAL AA-480-XX OUTDOOR THERMOELECTRIC COOLER ASSEMBLY USER S MANUAL Table of Contents Introduction 3 Incoming Inspection 3 General Safety & Warnings 3 Technical Specifications 4 Installation and Operation Instructions

More information

RIO 54 CEILING FAN MODEL # Español p. 19

RIO 54 CEILING FAN MODEL # Español p. 19 RIO 54 CEILING FAN MODEL #50195 Español p. 19 Questions, problems, missing parts? Before returning to your retailer, call our customer service department at 1-877-361-3883, Monday - Thursday, 8 am - 6

More information

C1D1 Explosion Proof 50W LED Flood Light Fixture - Paint Spray Booth Approved - Adj Surface Mount

C1D1 Explosion Proof 50W LED Flood Light Fixture - Paint Spray Booth Approved - Adj Surface Mount C1D1 Explosion Proof 50W LED Flood Light Fixture - Paint Spray Booth Approved - Adj Surface Mount Part #: EPL-LED-50W-RT-JB2 Page: 1 The Larson Electronics EPL-LED-50W-RT-JB2 Explosion Proof High Bay light

More information

INSTALLATION INSTRUCTIONS FOR 7330C740 FLUSH MOUNT CEILING ASSEMBLY

INSTALLATION INSTRUCTIONS FOR 7330C740 FLUSH MOUNT CEILING ASSEMBLY INSTALLATION INSTRUCTIONS FOR 7330C740 FLUSH MOUNT CEILING ASSEMBLY TABLE OF CONTENTS Warnings...3 Package Contents...3 General Information...3 Supply Ducting And Registers...3 Routing 115 VAC Wiring...5

More information

Table of Contents. What to Expect with. Mounting Options. Tools Needed. Wall Control

Table of Contents.   What to Expect with. Mounting Options. Tools Needed. Wall Control Table of Contents www.casablancafanco.com What to Expect with Your Installation Congratulations on purchasing your new Casablanca ceiling fan! It will provide comfort and performance in your home or office

More information

Installation Instructions

Installation Instructions Installation Instructions For Fully Integrated NoFrost Combined Refrigerator-Freezers HC 2062 HCB 2062 HC/HCB 20 7082 373-00 Important PLEASE READ AND FOLLOW THESE INSTRUCTIONS These instructions contain

More information

ITEM # SAIL STREAM CEILING FAN MODEL #40048

ITEM # SAIL STREAM CEILING FAN MODEL #40048 ITEM #0609448 SAIL STREAM CEILING FAN MODEL #40048 Harbor Breeze is a registered trademark of LF, LLC. All Rights Reserved. Español p. 19 ATTACH YOUR RECEIPT HERE Purchase Date Questions, problems, missing

More information

3MNLR72XXD Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 3MNLR72

3MNLR72XXD Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 3MNLR72 Owner s Guide and Installation Manual 3MNLR72XXD Series Fan UL Model NO. : 3MNLR72 Attach sales receipt to this card and retain as your proof of purchase DATE OF PURCHASE: MODEL NUMBER: RETAILER NAME:

More information

RESIN FREESTANDING TUB

RESIN FREESTANDING TUB RESIN FREESTANDING TUB INSTALLATION INSTRUCTIONS AND CARE GUIDE CONTENTS Tub Installation...2 Rough-In...2 Drain Installation...3 Air Tub Installation...4 Electrical Installation...4 Remote Control Installation...5

More information

ChicagoTM. Instruction Manual. Includes our new CoolTouch TM Control System Looks permanent, but goes wherever you go! U.S.

ChicagoTM. Instruction Manual. Includes our new CoolTouch TM Control System Looks permanent, but goes wherever you go! U.S. Includes our new CoolTouch TM Control System Looks permanent, but goes wherever you go! U.S. Patent Pending ChicagoTM A Kichler Decor ceiling fan Kichler Lighting 7711 East Pleasant Valley Road P.O. Box