Multiphase-Simulation of Membrane Humidifiers for PEM Fuel Cells

Size: px
Start display at page:

Download "Multiphase-Simulation of Membrane Humidifiers for PEM Fuel Cells"

Transcription

1 Multiphase-Simulation of Membrane Humidifiers for PEM Fuel Cells STAR Global Conference Sebastian Bilz, Vladimir Buday, Carolus Gruenig, Thomas von Unwerth Vienna, March 17-19,

2 CFD Simulation of Fuel Cell Humidifiers Overview Introduction Simulation Methodology Single-Duct Modelling Modelling of a Complete Humidifier Conclusion/Summary Outlook/Further Work 2

3 CFD Simulation of Fuel Cell Humidifiers Overview Introduction Simulation Methodology Single-Duct Modelling Modelling of a Complete Humidifier Conclusion/Summary Outlook/Further Work 3

4 Introduction Task/ Purpose Electrolyte of the fuel cell has to be hydrated to ensure proton conductivity An option: humidifier But: water management of a PEM fuel cell has to be well controlled to secure power in every operating point CFD simulation hydrogen electrical load gas with high relative humidity proton exchange membrane air gas diffusion layer bipolar plates anode electrode with catalyst cathode cf: Perma Pure cf: A. Vlath: Dreidimensionale dynamische Modellierung und Berechnung von PEM- Brennstoffzellen-systemen Development of a methodology to simulate a fuel cell humidifier with Star-CCM+ Examination of this methodology under different operating conditions 4

5 Introduction Functional Principle of the Humidifier Position of the humidifier in the cathode stream: Air Compressor Dry Humidifier Humid H 2 Fuel cell Anode Cathode Setup of the humidifier: Dry exhaust Bundle of pipes Humid exhaust Liquid water or gas with high humidity Dry air Humid air Exhaust stream Transport of moisture through the membrane 5

6 CFD Simulation of Fuel Cell Humidifiers Overview Introduction Simulation Methodology Single-Duct Modelling Modelling of a Complete Humidifier Conclusion/Summary Outlook/Further Work 6

7 Simulation Methodology Calculation of the Resulting Flux Example water-to-gas-humidifier: a A =f(λ) Liquid water Δx Membrane a I =f(λ) Δa Low humidity Air High humidity Procedure: 1. Writing the activity of both sides into tables interpolate them conditions are available on both sides of the membrane 2. The resulting flux is calculated by assuming a linear gradient 3. This flux is added to the inner region and subtracted from the outside 7

8 CFD Simulation of Fuel Cell Humidifiers Overview Introduction Simulation Methodology Single-Duct Modelling Modelling of a Complete Humidifier Conclusion/Summary Outlook/Further Work 8

9 1,4mm 4mm 0,127mm Single-Duct Modelling Design of the Simulation Model Geometrical data is taken from the humidifier: H 2 O Air H 2 O 254mm Inner fluid: cathode stream, fluid region with shell region on the wall for evaporation Membrane: properties of Nafion 115 for heat transfer, solid region Outer fluid: liquid water or cathode exhaust, fluid region (shell region condensation) 9

10 Mass fraction of H 2 O [-] Single-Duct Modelling Results of the Water-to-Gas-Humidifier Example: Temperature of water 40 C Volume flow of the cathode stream 357 l/min Mass Fraction (flow direction Z): Gas inlet Gas outlet Coordinate Z [m] 10

11 Single-Duct Modelling Results of the Water-to-Gas-Humidifier Example: Temperature of water 40 C Volume flow of the cathode stream 357 l/min Temperature (flow direction Z): Gas inlet Gas outlet Gas temperature [K] Relative Humidity [-] Coordinate Z [m] 11

12 Mass fraction of water at the outlet [-] Single-Duct Modelling Validation of the Water-to-Gas-Humidifier Variation of water temperature and volume flow of the cathode stream: T H2O = 80 C T H2O = 60 C T H2O = 40 C Volume flow of the cathode stream [l/min] Low change in temperature of the inner fluid means negligible error 12

13 Single-Duct Modelling Results of the Gas-to-Gas-Humidifier Example: Temperature of the exhaust 70 C, Volume flow of the cathode stream 60l/min Mass fraction (flow direction Z): Inlet of the cathode stream Outlet of the cathode stream Temperature (flow direction Z): Inlet of the cathode stream Outlet of the cathode stream 13

14 Single-Duct Modelling Validation of the Gas-to-Gas-Humidifier Variation of temperature of the outer gas with constant mass fraction Mass fraction H 2 O at the outlet of cathode stream Deviation to validation data Simulation Data sheet Mass fraction of the inner gas is influenced by the mass fraction of the outer gas Agrees with validation data 14

15 CFD Simulation of Fuel Cell Humidifiers Overview Introduction Simulation Methodology Single-Duct Modelling Modelling of a Complete Humidifier Conclusion/Summary Outlook/Further Work 15

16 Modelling of a Complete Humidifier Motivation Realistic description of the outer fluid (flow profile) Interaction of the pipes Transfer of the moisture in dependence of the position of the pipe Increase of accuracy Reality: irregular array Model: regular array 16

17 Modelling of a Complete Humidifier Design of the Simulation Model Fluid region water: 150 pipes modelled Solid/fluid region air: 4 representing pipes, transfer of the results to the surrounding pipes Inlet: air Inlet: water Outlet: air Outlet: water 17

18 Mass fraction H 2 O at the outlet [-] Temperature at the outlet [K] Modelling of a Complete Humidifier Results in Comparison with the Single Duct Mass fraction: Temperature: data sheet single duct humidifier single duct humidifier Volume flow of the cathode stream in [l/min] Volume flow of the cathode stream [l/min] Temperature of gases at the outlet agree with data of a single duct, But: constant offset in mass fraction of 0.02 No significant difference between the results of the positions of the 4 pipes Prospect: study of a gas-to-gas-humidifier 18

19 CFD Simulation of Fuel Cell Humidifiers Overview Introduction Simulation Methodology Single-Duct Modelling Modelling of a Complete Humidifier Conclusion/Summary Outlook/Further Work 19

20 CFD Simulation of Fuel Cell Humidifiers Conclusion / Summary Implementation of a suitable simulation approach Computation of multiphase flow with condensation and evaporation Calculation of the mass transfer through a semipermeable membrane with the help of field functions and tables Calculation of both operational strategies (gas-to-gas, water-to-gas) possible Achieved result accuracy Trend of the results agree with validation data, error sources are known But: no validation data for temperature or relative humidity Modelling/ simulation of complete humidifier Not feasible in terms of require computational efforts No advantage in simulation of the entire humidifier in operation with liquid water in comparison to the single-duct strategy Calculation with the help of the water content of the membrane matches water management in a fuel cell first step to simulate an entire fuel cell 20

21 CFD Simulation of Fuel Cell Humidifiers Overview Introduction Simulation Methodology Single-Duct Modelling Modelling of a Complete Humidifier Conclusion/Summary Outlook/Further Work 21

22 CFD Simulation of Fuel Cell Humidifiers Outlook / Future Work Measurement to get more validation data (heat transfer, temperature, relative humidity) Further development of the methodology to reduce errors Extension to consider other physical effects (membrane swelling, crossover of gases) Computation of an entire gas-to-gas-humidifier, comparison with single-duct-model 22

23 Thank you very much Sebastian Bilz IAV GmbH Rockwellstraße 16, Gifhorn 23

24 Appendix Comparison of Parameter: Model and Data Sheet Parameter Data Sheet Model Length 10 =254 mm 10 =254 mm Inner diameter of the pipe - Measured: 1,4 mm Membrane material Nafion Nafion 115 (based on membrane thickness) Properties of the membrane (porosity, tortuosity, Diffusion coefficient) - taken from literature, empirical equations Volume flow of air l/min l/min Inlet air temperature - 298,15 K Volume flow of water - 4,5E-3 (negligible) Inlet water temperature 1 40, 60, 75, 80 C 40, 60, 80 C Air temperature or relative humidity at outlet - computed Mass fraction of water of air at outlet Dew point temperature computed Water temperature 1 at the outlet - computed Mass fraction of water of the exhaust stream at the outlet 2 - computed 1: temperature of exhaust stream in case of a gas-to-gas humidifier 2: only in case of gas-to-gas humidifier 24

25 Appendix Interpolating of Activities Inner Activity Inner fluid Membrane Outer fluid Activity is written into a table at the inner membrane surface Interpolated with field function Values pertain for each volume element and change in z-direction (from inlet to outlet) Values are equal in the radial direction Resulting flux can be calculated in the inner and outer fluid region to subtract and add the same value 25

26 Appendix Comparison of the Fluid Film Thickness Small volume flow: Inlet Outlet Large volume flow: Inlet Outlet Small volume flow fluid film thickness grows saturated gas near the outlet Large volume flow minor fluid film thickness, remains constant unsaturated gas near the outlet 26

Application Note Automated Implementation of U.S. DOE PEM Fuel Cell Durability Protocols using Scribner Fuel Cell Test Systems

Application Note Automated Implementation of U.S. DOE PEM Fuel Cell Durability Protocols using Scribner Fuel Cell Test Systems Application Note Automated Implementation of U.S. DOE PEM Fuel Cell Durability Protocols using Scribner Fuel Cell Test Systems Introduction Durability is a key performance property of polymer electrolyte

More information

Compression of Fins pipe and simple Heat pipe Using CFD

Compression of Fins pipe and simple Heat pipe Using CFD Compression of Fins pipe and simple Heat pipe Using CFD 1. Prof.Bhoodev Mudgal 2. Prof. Gaurav Bhadoriya (e-mail-devmudgal.mudgal@gmail.com) ABSTRACT The aim of this paper is to identify the advantages

More information

Analysis of Constant Pressure and Constant Area Mixing Ejector Expansion Refrigeration System using R-1270 as Refrigerant

Analysis of Constant Pressure and Constant Area Mixing Ejector Expansion Refrigeration System using R-1270 as Refrigerant Analysis of Constant Pressure and Constant Area Mixing Ejector Expansion Refrigeration System using R-1270 as Refrigerant Ravi Verma 1, Sharad Chaudhary 2 1, 2 Department of Mechanical Engineering, IET

More information

CFD Analysis of temperature dissipation from a hollow metallic pipe through circular fins using Ansys 14.5

CFD Analysis of temperature dissipation from a hollow metallic pipe through circular fins using Ansys 14.5 IJAET International Journal of Application of Engineering and Technology ISSN: 2395-3594 Vol-1 No.-2 CFD Analysis of temperature dissipation from a hollow metallic pipe through circular fins using Ansys

More information

Development of the CMS Phase-1 Pixel Online Monitoring System and the Evolution of Pixel Leakage Current

Development of the CMS Phase-1 Pixel Online Monitoring System and the Evolution of Pixel Leakage Current Development of the CMS Phase-1 Pixel Online Monitoring System and the Evolution of Pixel Leakage Current Fengwangdong Zhang On behalf of CMS Pixel Collaboration The 9th International Workshop on Semiconductor

More information

1.1. SCOPE OF THE WORK:

1.1. SCOPE OF THE WORK: Chapter 1: Introduction 1 1. INTRODUCTION 1.1. SCOPE OF THE WORK: Multi-stage refrigeration systems are an area of growing industrial importance in large plants. These systems are known to be large power

More information

CHAPTER I INTRODUCTION. In the modern life, electronic equipments have made their way

CHAPTER I INTRODUCTION. In the modern life, electronic equipments have made their way 1 CHAPTER I INTRODUCTION In the modern life, electronic equipments have made their way in to practically every part, which is from electronic gadgets to high power computers. Electronic components have

More information

Pressure drop analysis of evaporator using refrigerants R-22, R-404A and R-407C

Pressure drop analysis of evaporator using refrigerants R-22, R-404A and R-407C drop analysis of evaporator using refrigerants R-22, R-404A and R-407C #1 Pallavi Sawkar, #2 Dr. Pradeep Patil #12 Department of Mechanical Engineering, JSPM s JSCOE, Savitribai Phule Pune University,

More information

INDOOR CLIMATE IN HEATING CONDITION OF A LARGE GYMNASIUM WITH UNDER-FLOOR SUPPLY/RETURN SYSTEM

INDOOR CLIMATE IN HEATING CONDITION OF A LARGE GYMNASIUM WITH UNDER-FLOOR SUPPLY/RETURN SYSTEM INDOOR CLIMATE IN HEATING CONDITION OF A LARGE GYMNASIUM WITH UNDER-FLOOR SUPPLY/RETURN SYSTEM Mingjie Zheng Research Laboratory, SANKO AIR CONDITIONING CO., LTD. Nagoya, 450-0003, JAPAN ABSTRACT In large

More information

Numerical study of heat pipe application in heat recovery systems

Numerical study of heat pipe application in heat recovery systems Numerical study of heat pipe application in heat recovery systems *Song Lin, John Broadbent, Ryan McGlen Thermacore Europe, 12 Wansbeck Business Park Ashington, Northumberland NE3 QW, UK E-mail: song.lin@thermacore.com

More information

Optimization of Thin Film Heater/Sensor Design for Miniature Devices Using Finite Element Analysis

Optimization of Thin Film Heater/Sensor Design for Miniature Devices Using Finite Element Analysis Electrical and Computer Engineering Research Facility Optimization of Thin Film Heater/Sensor Design for Miniature Devices Using Finite Element Analysis University of Alberta, Edmonton, Alberta Viet N.

More information

ZONE MODEL VERIFICATION BY ELECTRIC HEATER

ZONE MODEL VERIFICATION BY ELECTRIC HEATER , Volume 6, Number 4, p.284-290, 2004 ZONE MODEL VERIFICATION BY ELECTRIC HEATER Y.T. Chan Department of Building Services Engineering, The Hong Kong Polytechnic University, Hong Kong, China ABSTRACT Selecting

More information

Basic Input Data Needed to Develop a High Performance Fan/Blower with Low Noise, Energy Saving and High Efficiency

Basic Input Data Needed to Develop a High Performance Fan/Blower with Low Noise, Energy Saving and High Efficiency Basic Input Data Needed to Develop a High Performance Fan/Blower with Low Noise, Energy Saving and High Efficiency Haiye Lou TurboMoni Applied Dynamics Lab Abstract It is often happened, when a project

More information

Modeling of a regenerative indirect evaporative cooler for a desiccant cooling system

Modeling of a regenerative indirect evaporative cooler for a desiccant cooling system Downloaded from orbit.dtu.dk on: Jun 29, 2018 Modeling of a regenerative indirect evaporative cooler for a desiccant cooling system Bellemo, Lorenzo; Elmegaard, Brian; Reinholdt, Lars O. ; Kærn, Martin

More information

COMPLEX COMMISSIONING AND QUANTITATIVE TESTING GOTTHARD BASE TUNNEL VENTILATION SYSTEM

COMPLEX COMMISSIONING AND QUANTITATIVE TESTING GOTTHARD BASE TUNNEL VENTILATION SYSTEM COMPLEX COMMISSIONING AND QUANTITATIVE TESTING GOTTHARD BASE TUNNEL VENTILATION SYSTEM 8 th International Conference Tunnel Safety & Ventilation 2016 Martin Viertel OVERVIEW Gotthard Base Tunnel Ventilation

More information

Investigating the Effects of Sprinkler Sprays on Fire-Induced Doorway Flows: A Two-Part Study. Jeremiah Crocker and Dr. Bin Xiao New Technology Team

Investigating the Effects of Sprinkler Sprays on Fire-Induced Doorway Flows: A Two-Part Study. Jeremiah Crocker and Dr. Bin Xiao New Technology Team Jeremiah Crocker and Dr. Bin Xiao New Technology Team Copyright 2010 Tyco Fire Suppression & Building Products. All rights reserved. The products and specifications published herein are for general evaluation

More information

PERFORMANCE EVALUATION OF THE MINIATRIZED CATALYTIC COMBUSTION TYPE HYDROGEN SENSOR

PERFORMANCE EVALUATION OF THE MINIATRIZED CATALYTIC COMBUSTION TYPE HYDROGEN SENSOR PERFORMANCE EVALUATION OF THE MINIATRIZED CATALYTIC COMBUSTION TYPE HYDROGEN SENSOR Hiroshi Miyazaki 1, Hiromasa Tanjyoh 2, Kengo Suzuki 3, Tomoaki Iwami 4 1 New cosmos electric, co., ltd., Osaka, 543-0036,

More information

Efficiency of Application the Condensing Heat Utilizers in the Existing Boiler's Unit in Heat Power Station

Efficiency of Application the Condensing Heat Utilizers in the Existing Boiler's Unit in Heat Power Station Efficiency of Application the Condensing Heat Utilizers in the Existing Boiler's Unit in Heat Power Station Normuminov J.A. Assistant, Dean of Heat Power Engineering, Tashkent State Technical University,

More information

Development of a Transient Simulation Model of a Freezer Part II: Comparison of Experimental Data with Model

Development of a Transient Simulation Model of a Freezer Part II: Comparison of Experimental Data with Model Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 199 Development of a Transient Simulation Model of a Freezer Part II: Comparison

More information

Open and Closed Door Moisture Transport and Corresponding Energy Consumption in Household Refrigerator

Open and Closed Door Moisture Transport and Corresponding Energy Consumption in Household Refrigerator 18 R. Saidur et al./journal of Energy & Environment, Vol. 6, May 2007 Open and Closed Door Moisture Transport and Corresponding Energy Consumption in Household Refrigerator R. Saidur, M. A. Sattar, M.

More information

Desiccant Cooling with Solar Energy

Desiccant Cooling with Solar Energy Desiccant Cooling with Solar Energy Gerrit Höfker 1,2, Ursula Eicker 2, Kevin Lomas 1, Herbert Eppel 1 1 De Montfort University Leicester, Institute of Energy and Sustainable Development 2 Hochschule für

More information

Principles of Cold Insulation

Principles of Cold Insulation Principles of Cold Insulation FEDERATION EUROPEENNE DES SYNDICATS D ENTREPRISES D ISOLATION EUROPEAN FEDERATION OF ASSOCIATIONS OF INSULATION CONTRACTORS May 1997 www.fesi.eu Principles of cold insulation

More information

Performance Comparison of Ejector Expansion Refrigeration Cycle with Throttled Expansion Cycle Using R-170 as Refrigerant

Performance Comparison of Ejector Expansion Refrigeration Cycle with Throttled Expansion Cycle Using R-170 as Refrigerant International Journal of Scientific and Research Publications, Volume 4, Issue 7, July 2014 1 Performance Comparison of Ejector Expansion Refrigeration Cycle with Throttled Expansion Cycle Using R-170

More information

Performance Study of Triple Concentric Pipe Heat Exchanger

Performance Study of Triple Concentric Pipe Heat Exchanger Performance Study of Triple Concentric Pipe Heat Exchanger #1 Pravin M. Linge, #2 A. B. Korane, #3 V. N. Kapatkar #123 Mechanical Engineering Department, Sinhgad College of Engineering, SPPU, Pune, India

More information

Experimental investigation of Hybrid Nanofluid on wickless heat pipe heat exchanger thermal performance

Experimental investigation of Hybrid Nanofluid on wickless heat pipe heat exchanger thermal performance Experimental investigation of Hybrid Nanofluid on wickless heat pipe heat exchanger thermal performance #1 Jaydev S. Bade, #2 Dr. Nitin U. Korde 1 Department of Mechanical Engineering, Savitribai Phule

More information

Modelling the Performance of a Diffusion Absorption Refrigeration System

Modelling the Performance of a Diffusion Absorption Refrigeration System Modelling the Performance of a Diffusion Absorption Refrigeration System Noman Yousuf 1, Etienne Biteau 2, Timothy Anderson 1, Michael Gschwendtner 1 and Roy Nates 1 1 School of Engineering, Auckland University

More information

2. HEAT EXCHANGERS MESA

2. HEAT EXCHANGERS MESA 1. INTRODUCTION Multiport minichannel and microchannel aluminium tubes are becoming more popular as components in heat exchangers. These heat exchangers are used in various industrial applications and

More information

Using FDS Modelling to Establish Performance Criteria for Water Mist Systems on Very Large Fires in Tunnels

Using FDS Modelling to Establish Performance Criteria for Water Mist Systems on Very Large Fires in Tunnels Using FDS Modelling to Establish Performance Criteria for Water Mist Systems on Very Large Fires in Tunnels Jack R. Mawhinney, P. Eng., FSFPE Javier J. Trelles, Ph.D. Authors & acknowledgement J. R. Mawhinney

More information

An Experiment of Heat Exchanger Produces Hot Water Using Waste Heat Recovery from Air Conditioning

An Experiment of Heat Exchanger Produces Hot Water Using Waste Heat Recovery from Air Conditioning ISBN 978-93-84468-94-1 International Conference on Education, Business and Management (ICEBM-2017) Bali (Indonesia) Jan. 8-9, 2017 An Experiment of Heat Exchanger Produces Hot Water Using Waste Heat Recovery

More information

CFD Analysis of a 24 Hour Operating Solar Refrigeration Absorption Technology

CFD Analysis of a 24 Hour Operating Solar Refrigeration Absorption Technology IJIRST International Journal for Innovative Research in Science & Technology Volume 1 Issue 11 April 2015 ISSN (online): 2349-6010 CFD Analysis of a 24 Hour Operating Solar Refrigeration Absorption Technology

More information

Performance analysis of ejector refrigeration system with environment friendly refrigerant driven by exhaust emission of automobile

Performance analysis of ejector refrigeration system with environment friendly refrigerant driven by exhaust emission of automobile Available online at www.pelagiaresearchlibrary.com Advances in Applied Science Research, 2013, 4(5):232-237 ISSN: 0976-8610 CODEN (USA): AASRFC Performance analysis of ejector refrigeration system with

More information

Dynamic Simulation of Double Pipe Heat Exchanger using MATLAB simulink

Dynamic Simulation of Double Pipe Heat Exchanger using MATLAB simulink Dynamic Simulation of Double Pipe Heat Exchanger using MATLAB simulink 1 Asoka R.G, 2 Aishwarya N, 3 Rajasekar S and 4 Meyyappan N 1234 Department of Chemical Engineering Sri Venkateswara College of Engineering,

More information

MODELLING AND OPTIMIZATION OF DIRECT EXPANSION AIR CONDITIONING SYSTEM FOR COMMERCIAL BUILDING ENERGY SAVING

MODELLING AND OPTIMIZATION OF DIRECT EXPANSION AIR CONDITIONING SYSTEM FOR COMMERCIAL BUILDING ENERGY SAVING MODELLING AND OPTIMIZATION OF DIRECT EXPANSION AIR CONDITIONING SYSTEM FOR COMMERCIAL BUILDING ENERGY SAVING V. Vakiloroaya*, J.G. Zhu, and Q.P. Ha School of Electrical, Mechanical and Mechatronic Systems,

More information

Shortcut Model for Predicting Refrigeration Cycle Performance

Shortcut Model for Predicting Refrigeration Cycle Performance 17 A publication of CHEMICAL ENGINEERING TRANSACTIONS VOL. 5, 15 Guest Editors: Petar Sabev Varbanov, Jiří Jaromír Klemeš, Sharifah Rafidah Wan Alwi, Jun Yow Yong, Xia Liu Copyright 15, AIDIC Servizi S.r.l.,

More information

4th International Conference on Sensors, Measurement and Intelligent Materials (ICSMIM 2015)

4th International Conference on Sensors, Measurement and Intelligent Materials (ICSMIM 2015) 4th International Conference on Sensors, Measurement and Intelligent Materials (ICSMIM 2015) Multi-stage Series Heat Pump Drying System with Dehumidification Simulation and Experiment Verification Chao

More information

Mechanical Engineering Department Sheet (1)

Mechanical Engineering Department Sheet (1) Benha University Heat and Mass Transfer Faculty of Engineering at Shoubra 3 rd Year (Power) Mechanical Engineering Department Sheet (1) (1) What is heat exchanger? Mention with brief description and sketches

More information

Heating and Air-Conditioning Testing II. Climatic Test Bench

Heating and Air-Conditioning Testing II. Climatic Test Bench Heating and Air-Conditioning Testing II Climatic Test Bench Heating and Air-Conditioning Testing II Climatic Test Bench Content IAV's Climatic Test Benches 4 Mobile Coolant Circuit 6 Evaporator Air Treatment

More information

GASS Module. User Manual. Gas Analysis Sampling System PERMA PURE

GASS Module. User Manual. Gas Analysis Sampling System PERMA PURE GASS Module Gas Analysis Sampling System User Manual PERMA PURE 8 Executive Drive Toms River, N.J. 08755 Phone: 800-337-3762 732-244-0010 Fax: 732-244-8140 e-mail: info@permapure.com Web Site: www.permapure.com

More information

Clemens Felsmann 1, Jean Lebrun 2, Vincent Lemort 2 and Aad Wijsman 3 ABSTRACT INTRODUCTION METHODOLOGY

Clemens Felsmann 1, Jean Lebrun 2, Vincent Lemort 2 and Aad Wijsman 3 ABSTRACT INTRODUCTION METHODOLOGY Eleventh International IBPSA Conference Glasgow, Scotland July 27-30, 2009 TESTING AND VALIDATION OF SIMULATION TOOLS OF HVAC MECHANICAL EQUIPMENT INCLUDING THEIR CONTROL STRATEGIES. PART II: VALIDATION

More information

Updates to the Ground Infiltration Module in InfoWorks ICM 8.0

Updates to the Ground Infiltration Module in InfoWorks ICM 8.0 Updates to the Ground Infiltration Module in InfoWorks ICM 8.0 Introduction The release of InfoWorks ICM version 8.0 has seen a couple of additional features added to the Ground Infiltration module to

More information

Smoke Layer Height and Heat Flow through a Door

Smoke Layer Height and Heat Flow through a Door Smoke Layer Height and Heat Flow through a Door 2018 Smoke Layer Height and Heat Flow through a Door In this tutorial you will simulate a growing fire in the corner of a 5m x 5m room. The room has a 1m

More information

Evaluation of a dynamic model for a cold climate counter flow air to air heat exchanger

Evaluation of a dynamic model for a cold climate counter flow air to air heat exchanger Evaluation of a dynamic model for a cold climate counter flow air to air heat exchanger Toke Rammer Nielsen, Associate Professor, Department of Civil Engineering, Technical University of Denmark; trn@byg.dtu.dk

More information

1 Air Handling Units In ICE

1 Air Handling Units In ICE 1 Air Handling Units In ICE From version 3.0, there is a library of common air handling units (AHU) in the distribution. A simulated building can have several AHUs. The following limitations apply: - every

More information

Recent Advances in Fire Suppression Modeling Issues & Perspectives of Fire Safety Engineering Applications

Recent Advances in Fire Suppression Modeling Issues & Perspectives of Fire Safety Engineering Applications Recent Advances in Fire Suppression Modeling Issues & Perspectives of Fire Safety Engineering Applications Pianet Grégoire Studies and modelling section manager Fire and Environmental Department, CNPP

More information

Heat Exchangers. Heat Exchangers 1

Heat Exchangers. Heat Exchangers 1 Heat Exchangers Heat Exchangers 1 How is the heat transfer? Mechanism of Convection Applications. Mean fluid Velocity and Boundary and their effect on the rate of heat transfer. Fundamental equation of

More information

Effects of Flash and Vapor Injection on the Air-to- Air Heat Pump System

Effects of Flash and Vapor Injection on the Air-to- Air Heat Pump System Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2010 Effects of Flash and Vapor Injection on the Air-to- Air Heat Pump System

More information

Smoldering Propagation Characteristics of Flexible Polyurethane Foam under Different Air Flow Rates

Smoldering Propagation Characteristics of Flexible Polyurethane Foam under Different Air Flow Rates Smoldering Propagation Characteristics of Flexible Polyurethane Foam under Different Air Flow Rates Zhou Y., Fei Y.*, Hu S. Q. Nanjing Tech University, College of Fire Safety Science and Engineering &

More information

Cooperation of a Steam Condenser with a Low-pressure Part of a Steam Turbine in Off-design Conditions

Cooperation of a Steam Condenser with a Low-pressure Part of a Steam Turbine in Off-design Conditions American Journal of Energy Research, 215, Vol. 3, No. 1, 13-18 Available online at http://pubs.sciepub.com/ajer/3/1/3 Science and Education Publishing DOI:1.12691/ajer-3-1-3 Cooperation of a Steam Condenser

More information

SECTION Free/Available Chlorine Analysis System

SECTION Free/Available Chlorine Analysis System SECTION 40 75 21 Free/Available Chlorine Analysis System PART 1 General 1.01 SUMMARY A. Requirements for a digital sensor system for free chlorine measurement for disinfection purposes in drinking water,

More information

Numerical Stability Analysis of a Natural Circulation Steam Generator with a Non-uniform Heating Profile over the tube length

Numerical Stability Analysis of a Natural Circulation Steam Generator with a Non-uniform Heating Profile over the tube length Numerical Stability Analysis of a Natural Circulation Steam Generator with a Non-uniform Heating Profile over the tube length HEIMO WALTER Institute for Thermodynamics and Energy Conversion Vienna University

More information

Numerical Studies On The Performance Of Methanol Based Air To Air Heat Pipe Heat Exchanger

Numerical Studies On The Performance Of Methanol Based Air To Air Heat Pipe Heat Exchanger International Journal of ChemTech Research CODEN( USA) IJCRGG ISSN 0974-4290 Vol.5, No.2, pp 925-934, April-June 2013 ICGSEE-2013[14th 16th March 2013] International Conference on Global Scenario in Environment

More information

ME 410 MECHANICAL ENGINEERING SYSTEMS LABORATORY MASS & ENERGY BALANCES IN PSYCHROMETRIC PROCESSES EXPERIMENT 3

ME 410 MECHANICAL ENGINEERING SYSTEMS LABORATORY MASS & ENERGY BALANCES IN PSYCHROMETRIC PROCESSES EXPERIMENT 3 ME 410 MECHANICAL ENGINEERING SYSTEMS LABORATORY MASS & ENERGY BALANCES IN PSYCHROMETRIC PROCESSES EXPERIMENT 3 1. OBJECTIVE The objective of this experiment is to observe four basic psychrometric processes

More information

Computerized Simulation of Automotive Air-Conditioning System: A Parametric Study

Computerized Simulation of Automotive Air-Conditioning System: A Parametric Study www.ijcsi.org 787 Computerized Simulation of Automotive Air-Conditioning System: A Parametric Study Haslinda Mohamed Kamar 1, Nazri Kamsah 2 and Mohd Yusoff Senawi 3 1 Department of Thermo-Fluid, Universiti

More information

(Refer Slide Time: 00:00:40 min)

(Refer Slide Time: 00:00:40 min) Refrigeration and Air Conditioning Prof. M. Ramgopal Department of Mechanical Engineering Indian Institute of Technology, Kharagpur Lecture No. # 10 Vapour Compression Refrigeration Systems (Refer Slide

More information

Automated Optimization of Air Conditioning Systems using Geometry based Simulation Models

Automated Optimization of Air Conditioning Systems using Geometry based Simulation Models Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 216 Automated Optimization of Air Conditioning Systems using Geometry based

More information

LOW-NOX BURNER RETROFIT CHALLENGE

LOW-NOX BURNER RETROFIT CHALLENGE LOW-NOX BURNER RETROFIT CHALLENGE By Craig Lieb Applications Engineer Zeeco, Inc. Rutland, UK Ryan Roberts Project Engineering Manager Zeeco, Inc. Broken Arrow, OK, U.S.A. Ryan Roberts has more than 20

More information

Simulation in papermaking a way to reduce costs

Simulation in papermaking a way to reduce costs P. Leuk 1, M. Schneeberger 1, P. Fisera 2, M.Dauer 1, U. Hirn 1, W. Bauer 1 1 TU Graz, Institut für Papier, Zellstoff- und Fasertechnik, Inffeldgasse 23, 8010 Graz, Austria 2 Consulting Fisera, Schulstrasse

More information

A Study on the 2-D Temperature Distribution of the Strip due to Induction Heater

A Study on the 2-D Temperature Distribution of the Strip due to Induction Heater , pp.1-5 http://dx.doi.org/10.14257/astl.2015.90.01 A Study on the 2-D Temperature Distribution of the Strip due to Induction Heater Jong-Hyun Lee 1, Jin-Taek Kim 1, Sung-Hyuk Lim 2, Do-Gyun Jung 2, Hyeong-Jin

More information

International Forum on Energy, Environment Science and Materials (IFEESM 2015)

International Forum on Energy, Environment Science and Materials (IFEESM 2015) The Comparison and Analysis of Humidity Environment between Floor and Ceiling Radiant Cooling Systems that Combined with Displacement Ventilation Kai SUN 1 a *, Chuan-hui ZHOU 1 1 College of Urban Construction,

More information

HEFAT th International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics Sun City, South Africa Paper number:pp1

HEFAT th International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics Sun City, South Africa Paper number:pp1 HEFAT27 5 th International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics Sun City, South Africa Paper number:pp PERFORMANCE ANALYSIS OF AIR-COOLED CONDENSER USING MICRO-FIN TUBES P.A.Patil

More information

Analysis of Evaporative Cooler and Tube in Tube Heat Exchanger in Intercooling of Gas Turbine

Analysis of Evaporative Cooler and Tube in Tube Heat Exchanger in Intercooling of Gas Turbine IJIRST International Journal for Innovative Research in Science & Technology Volume 1 Issue 11 April 2015 ISSN (online): 2349-6010 Analysis of Evaporative Cooler and Tube in Tube Heat Exchanger in Intercooling

More information

ENERGY ANALYSIS OF HEAT PUMP WITH SUBCOOLER

ENERGY ANALYSIS OF HEAT PUMP WITH SUBCOOLER Poster P.4.2 - - ENERGY ANALYSIS OF HEAT PUMP WITH SUBCOOLER Jan Sedlar, University Centre for Energy Efficient Buildings and Faculty of Mechanical Engineering, Czech Technical University in Prague, Czech

More information

Refrigerant Glide and Effect on Performances Declaration

Refrigerant Glide and Effect on Performances Declaration Refrigerant Glide and Effect on Performances Declaration Scope and Purpose As a consequence of the EU regulation 517/2014 (F-gas), the future synthetic refrigerants with a low global warming potential

More information

IP TRONIK. Project Scope: Simulation of car refrigerant circuit with the software GT SUITE and its comparison with real test bench measurements

IP TRONIK. Project Scope: Simulation of car refrigerant circuit with the software GT SUITE and its comparison with real test bench measurements IP TRONIK EICHSTÄTT GMBH Project Scope: Simulation of car refrigerant circuit with the software GT SUITE and its comparison with real test bench measurements Christian Schwegler 17. October 2016 Table

More information

Heat and Mass Transfer in Fibrous Materials. Theory and Applications. A.K. Haghi S. Thomas L.A. Pothan ATLANTIC PUBLISHERS & DISTRIBUTORS (P) LTD

Heat and Mass Transfer in Fibrous Materials. Theory and Applications. A.K. Haghi S. Thomas L.A. Pothan ATLANTIC PUBLISHERS & DISTRIBUTORS (P) LTD Heat and Mass Transfer in Fibrous Materials Theory and Applications A.K. Haghi S. Thomas L.A. Pothan ATLANTIC PUBLISHERS & DISTRIBUTORS (P) LTD Preface v Nomenclature (Part 1) xii PART 1 THEORY 1. Basic

More information

January 16 th, 2014 New York City

January 16 th, 2014 New York City Compressor Calorimeter Test of R-404A Alternative Refrigerants ARM-31a, D2Y-65, L-40, and R-32/R- 134a (50/50) in Medium Temperature Refrigeration Scroll Compressor Som Shrestha Omar Abdelaziz January

More information

Numerical investigation on the effect of channelled and unchannelled screens on smoke contamination in atriums upper balconies with open upstand

Numerical investigation on the effect of channelled and unchannelled screens on smoke contamination in atriums upper balconies with open upstand Numerical investigation on the effect of channelled and unchannelled screens on smoke contamination in atriums upper balconies with open upstand Mohammed Mutafi 1, Mohammad Nasif 1*, William Pao 1 and

More information

Life-Cycle Energy Costs and Greenhouse Gas Emissions for Gas Turbine Power

Life-Cycle Energy Costs and Greenhouse Gas Emissions for Gas Turbine Power energy center Paper Report Summary 210-1 174-2 Fixed and Floating Head Pressure Comparison for Madison Ice Arena Life-Cycle Energy Costs and Greenhouse Gas Emissions for Gas Turbine Power July 1998 April,

More information

Aalborg Universitet. Diffuse Ceiling Inlet Systems and the Room Air Distribution Nielsen, Peter Vilhelm; Jensen, Rasmus Lund; Rong, Li

Aalborg Universitet. Diffuse Ceiling Inlet Systems and the Room Air Distribution Nielsen, Peter Vilhelm; Jensen, Rasmus Lund; Rong, Li Aalborg Universitet Diffuse Ceiling Inlet Systems and the Room Air Distribution Nielsen, Peter Vilhelm; Jensen, Rasmus Lund; Rong, Li Published in: Clima 2010 : 10th Rehva World Congress Publication date:

More information

edry Model Based Paper Machine Drying Optimization

edry Model Based Paper Machine Drying Optimization Model Based Paper Machine Drying Optimization www.automationx.com www.procsim.eu Agenda Company Presentation The Energy used in Paper Making Potentials for Dryer Steam Reduction edry Solution ( How it

More information

MAL-DISTRIBUTION MODEL OF HEAT EXCHANGERS IN MICRO CHANNEL EVAPORATOR

MAL-DISTRIBUTION MODEL OF HEAT EXCHANGERS IN MICRO CHANNEL EVAPORATOR MAL-DISTRIBUTION MODEL OF HEAT EXCHANGERS IN MICRO CHANNEL EVAPORATOR Santhosh Kumar Student(M.Tech), Mechanical Dept Gokul group of institutions Visakhapatnam, India M Karteek Naidu ASST PROFF, Mechanical

More information

Some Modeling Improvements for Unitary Air Conditioners and Heat Pumps at Off-Design Conditions

Some Modeling Improvements for Unitary Air Conditioners and Heat Pumps at Off-Design Conditions Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2006 Some Modeling Improvements for Unitary Air Conditioners and Heat Pumps

More information

Performance of Water-in-Glass Evacuated Tube Solar Water Heaters

Performance of Water-in-Glass Evacuated Tube Solar Water Heaters Performance of Water-in-Glass Evacuated Tube Solar Water Heaters I. and G.L.Morrison School of Mechanical and Manufacturing Engineering University of New South Wales Sydney 2052 AUSTRALIA E-mail: g.morrison@unsw.edu.au

More information

FS 231: Final Exam (5-6-05) Part A (Closed Book): 60 points

FS 231: Final Exam (5-6-05) Part A (Closed Book): 60 points Name: Start time: End time: FS 231: Final Exam (5-6-05) Part A (Closed Book): 60 points 1. What are the units of the following quantities? (10 points) a. Enthalpy of a refrigerant b. Dryness fraction of

More information

Role of Nano-technology for improving of thermal performances of vapour compression refrigeration system (VCRS): An Overview

Role of Nano-technology for improving of thermal performances of vapour compression refrigeration system (VCRS): An Overview International Journal of Research in Engineering and Innovation Vol-2, Issue-1 (2018), 21-28 International Journal of Research in Engineering and Innovation (IJREI) journal home page: http://www.ijrei.com

More information

Experimental study on heat transfer characteristics of horizontal concentric tube using twisted wire brush inserts

Experimental study on heat transfer characteristics of horizontal concentric tube using twisted wire brush inserts International Journal of Current Engineering and Technology E-ISSN 2277 416, P-ISSN 2347 5161 216 INPRESSCO, All Rights Reserved Available at http://inpressco.com/category/ijcet Research Article Experimental

More information

Implementation and testing of a model for the calculation of equilibrium between components of a refrigeration installation

Implementation and testing of a model for the calculation of equilibrium between components of a refrigeration installation Implementation and testing of a model for the calculation of equilibrium between components of a refrigeration installation Marco Alexandre Onofre Dias This paper presents a model that was implemented

More information

PREDICTION OF THE PRESSURE DROP OF CO 2 IN AN EVAPORATOR USED FOR AIR COOLING ABSTRACT 1. INTRODUCTION 2. EXPERIMENTAL SET-UP AND PROCEDURE

PREDICTION OF THE PRESSURE DROP OF CO 2 IN AN EVAPORATOR USED FOR AIR COOLING ABSTRACT 1. INTRODUCTION 2. EXPERIMENTAL SET-UP AND PROCEDURE PREDICTION OF THE PRESSURE DROP OF CO 2 IN AN EVAPORATOR USED FOR AIR COOLING M. POIRIER, D. GIGUÈRE, Z. AIDOUN, M. OUZZANE Natural Resources Canada, CANMET Energy Technology Centre-Varennes 1615, Lionel

More information

FSTC Equipment Test Report

FSTC Equipment Test Report FSTC Equipment Test Report Purpose of Testing The Stirling Ultracold SU780XLE freezer was tested to characterize its energy usage and temperature stability during periods of both idle and door openings

More information

Developing a Fire Test Strategy for Storage Protection Under Sloped Ceilings

Developing a Fire Test Strategy for Storage Protection Under Sloped Ceilings Developing a Fire Test Strategy for Storage Protection Under Sloped Ceilings Justin A. Geiman, Noah L. Ryder Fire & Risk Alliance, Rockville, MD, USA André W. Marshall Custom Spray Solutions, Silver Spring,

More information

A STUDY ON THE BEHAVIOR OF STEAM CONDENSATION IN U-SHAPED HEAT TUBE

A STUDY ON THE BEHAVIOR OF STEAM CONDENSATION IN U-SHAPED HEAT TUBE A STUDY ON THE BEHAVIOR OF STEAM CONDENSATION IN U-SHAPED HEAT TUBE Satoru Ito 1, Keisuke Tsukada 1, Nobuyoshi Tsuzuki 2, Takao Ishizuka 3 and Hiroshige Kikura 3 1 Department of nuclear Engineering, Graduate

More information

EEN-E Measurement and Control of Energy Systems DRYING OF BIOMASS IN A FIXED BED DRYER LABORATORY EXERCISE INSTRUCTIONS

EEN-E Measurement and Control of Energy Systems DRYING OF BIOMASS IN A FIXED BED DRYER LABORATORY EXERCISE INSTRUCTIONS EEN-E1040 - Measurement and Control of Energy Systems DRYING OF BIOMASS IN A FIXED BED DRYER LABORATORY EXERCISE INSTRUCTIONS Aalto University Laboratory of Energy Efficiency and Systems 2016 Table of

More information

AND AIR-CONDITIONING. Dr Ali Jawarneh Department of Mechanical Engineering Hashemite University

AND AIR-CONDITIONING. Dr Ali Jawarneh Department of Mechanical Engineering Hashemite University Chapter 14 GAS VAPOR MIXTURES AND AIR-CONDITIONING Dr Ali Jawarneh Department of Mechanical Engineering Hashemite University 2 Objectives Differentiate between dry air and atmospheric air. Define and calculate

More information

HOW TO REDUCE ENERGY CONSUMPTION OF BUILT-IN REFRIGERATORS?

HOW TO REDUCE ENERGY CONSUMPTION OF BUILT-IN REFRIGERATORS? HOW TO REDUCE ENERGY CONSUMPTION OF BUILT-IN REFRIGERATORS? Corresponding author: Jasmin Geppert University of Bonn Household and Appliance Technology Section Nussallee 5 D-53115 Bonn E-Mail: haushaltstechnik@uni-bonn.de

More information

Available online Journal of Scientific and Engineering Research, 2017, 4(12): Research Article

Available online   Journal of Scientific and Engineering Research, 2017, 4(12): Research Article Available online www.jsaer.com, 2017, 4(12):203-209 Research Article ISSN: 2394-2630 CODEN(USA): JSERBR Evaluation of Ambient Temperature and Relative Humidity Distribution in Empty Cold Store with Chiller

More information

Jülich Solar Power Tower System Behavior During Downtime

Jülich Solar Power Tower System Behavior During Downtime Jülich Solar Power Tower System Behavior During Downtime Torsten Baumann 1, a), Felix Göhring 1, b), Hannes Stadler 1,c) and Till Doerbeck 2,d) 1 German Aerospace Center (DLR), Institute of Solar Research,

More information

Considerations in the Design of Smoke Management Systems for Atriums

Considerations in the Design of Smoke Management Systems for Atriums Construction Technology Update No. 48 Considerations in the Design of Smoke Management Systems for Atriums by G.D. Lougheed This Update discusses the use of an engineered approach to the design of smoke

More information

Fig.: macroscopic kinetic energy is an organized form of energy and is much more useful

Fig.: macroscopic kinetic energy is an organized form of energy and is much more useful Harnessing Energy Fig.: macroscopic kinetic energy is an organized form of energy and is much more useful Vapor Power Cycle The vast majority of electrical generating plants are variations of vapor power

More information

Reducing energy consumption of airconditioning systems in moderate climates by applying indirect evaporative cooling

Reducing energy consumption of airconditioning systems in moderate climates by applying indirect evaporative cooling Reducing energy consumption of airconditioning systems in moderate climates by applying indirect evaporative cooling Aleksandra Cichoń,*, Anna Pacak, Demis Pandelidis, and Sergey Anisimov Department of

More information

Performance test of a helium refrigerator for the cryogenic hydrogen system in J-PARC

Performance test of a helium refrigerator for the cryogenic hydrogen system in J-PARC Proceedings of ICEC -ICMC 8, edited by Ho-Myung CHANG et al. c 9 The Korea Institute of Applied Superconductivity and Cryogenics 978-89-978-- Performance test of a helium refrigerator for the cryogenic

More information

ANALYSIS ON EFFECT OF TEMPERATURE ON MOISTURE SEPARATION IN AIR COMPRESSOR

ANALYSIS ON EFFECT OF TEMPERATURE ON MOISTURE SEPARATION IN AIR COMPRESSOR International Journal of Scientific Engineering and Applied Science (IJSEAS) - Volume-1, Issue-2, June2015 ANALYSIS ON EFFECT OF TEMPERATURE ON MOISTURE SEPARATION IN AIR COMPRESSOR Suraj Ghiwe 1, K.V.

More information

Potential and Simulation of Open-Cycle Solar-Assisted Climatisation-Plants in Single-Family-Houses

Potential and Simulation of Open-Cycle Solar-Assisted Climatisation-Plants in Single-Family-Houses Proc. International Conference Solar Air-Conditioning, Staffelstein (DE), 6.-7.10.2005, pp. 236-240 Potential and Simulation of Open-Cycle Solar-Assisted Climatisation-Plants in Single-Family-Houses R.Heinzen,

More information

Experimental Investigation of a Multi Effect Membrane Based Regenerator for High Concentration Aqueous LiCL Solution as Desiccant

Experimental Investigation of a Multi Effect Membrane Based Regenerator for High Concentration Aqueous LiCL Solution as Desiccant Proceedings of the World Congress on Momentum, Heat and Mass Transfer (MHMT 16) Prague, Czech Republic April 4 5, 216 Paper No. ENFHT 111 DOI: 1.11159/enfht16.111 Experimental Investigation of a Multi

More information

Refining and Petrochemical Heater trouble shooting

Refining and Petrochemical Heater trouble shooting Refining and Petrochemical Heater trouble shooting 16 Oil&Gas Special Report TEXT 260417.indd 16 Heater trouble shooting Refining and Petrochemical It s Getting Hot in Here! Zeeco solves the mystery of

More information

CFD Model of a Specific Fire Scenario

CFD Model of a Specific Fire Scenario 16 th Australasian Fluid Mechanics Conference Crown Plaza, Gold Coast, Australia 2-7 December 27 CFD Model of a Specific Fire Scenario D. Mackay, T. Barber and E. Leonardi School of Mechanical and Manufacturing

More information

GAW - WCCAP recommendation for aerosol drying

GAW - WCCAP recommendation for aerosol drying GAW - WCCAP recommendation for aerosol drying Alfred Wiedensohler and Wolfram Birmili Leibniz Institute for Tropospheric Research Humidity control One particular problem during summertime or in warm and

More information

Techniques of Heat Transfer Enhancement and their Application. Chapter 4. Performance Evaluation Criteria for Two-Phase Heat Exchangers

Techniques of Heat Transfer Enhancement and their Application. Chapter 4. Performance Evaluation Criteria for Two-Phase Heat Exchangers Chapter 4 Performance Evaluation Criteria for Two-Phase Heat Exchangers Prof. Min Zeng 1/50 1. Introduction 2. Operating Characteristics of Two-phase Heat Exchangers 3. Enhancement in Two-Phase Heat Exchange

More information

Modeling of Ceiling Fan Based on Velocity Measurement for CFD Simulation of Airflow in Large Room

Modeling of Ceiling Fan Based on Velocity Measurement for CFD Simulation of Airflow in Large Room Modeling of Ceiling Fan Based on Velocity Measurement for CFD Simulation of Airflow in Large Room Y. Momoi 1, K. Sagara 1, T. Yamanaka 1 and H. Kotani 1 1 Osaka University, Graduate School of Eng., Dept.

More information

Heat Transfer Analysis of Vapor Compression System Using Nano Cuo-R134a

Heat Transfer Analysis of Vapor Compression System Using Nano Cuo-R134a 2011 International Conference on Advanced Materials Engineering IPCSIT vol.15 (2011) (2011) IACSIT Press, Singapore Heat Transfer Analysis of Vapor Compression System Using Nano Cuo-R134a Eed Abdel-Hafez

More information

WORK STUDY ON LOW TEMPERATURE (CASCADE) REFRIGERATION SYSTEM

WORK STUDY ON LOW TEMPERATURE (CASCADE) REFRIGERATION SYSTEM WORK STUDY ON LOW TEMPERATURE (CASCADE) REFRIGERATION SYSTEM Sachin Kumar 1, Vicky Ranga 2 1Assistant Professor, Department of Mechanical Engineering, Jagan Nath University Jhajjar, Haryana, India. 2Scholar.

More information