Radiator Connection System, Thermostatic Valve and Return Valve with Shutoff Function

Size: px
Start display at page:

Download "Radiator Connection System, Thermostatic Valve and Return Valve with Shutoff Function"

Transcription

1 HERZ-3000 Radiator Connection System, Thermostatic Valve and Return Valve with Shutoff Function Standard Sheet for Edition 1000 (0999) Dimensions in mm Cone sleeve Connection nipple 4215 HERZ-3000-Thermostatic Valves, Bypass Bodies for One-Pipe Systems In-line model, freely moving nut at the radiator side, male thread G 3/4 for compression union at the pipe side. Pipe connections to be ordered separately G 3/4 2 cone sleeves enclosed Rp 1/2 x G 3/4 2 connection nipples enclosed. Models for One-Pipe Systems HERZ-3000-Thermostatic Valves, Connection Elements for Two-Pipe Systems In-line model, freely moving nut at the radiator side, male thread G 3/4 for compression union at the pipe side. Pipe connections to be ordered separately G 3/4 2 cone sleeves enclosed Rp 1/2 x G 3/4 2 connection nipples enclosed. Two-Pipe Systems The HERZ-3000-thermostatic valve combines a thermostatic valve and a return valve with shutoff function in a single fitting with the thermostatic sensor element being placed in a position favourable from the viewpoint of heat flow. Special Design Features The models are marked by figures on the valve body: 1 Bypass bodies for one-pipe systems 2 Connection elements for two-pipe systems Marking of Models HERZ-3000-thermostatic valves are suitable for all radiators with connection from below, with a distance between centres of 50 mm ± 1.5 mm, and connection threads G 3/4 or Rp 1/2. During installation, take into account the arrows at the valve body. For systems with pipe coming out of the wall, use connection elbows G 3/4 ( ) between the HERZ-3000-thermostatic valve and the pipes. In case of radiators with integrated valves it is not necessary to install a thermostatic insert. The connection thread is closed with a plug. Mode of Installation We reserve the right to make modifications necessitated by technological progress.

2 One- and two-pipe water heating systems with calibrated steel, copper or plastic pipes. Maximum operating temperature 110 C Maximum operating pressure 10 bar Hot water purity in accordance with Austrian standard ÖNORM H 5195 and/or VDI-guideline When using HERZ compression unions for copper and steel pipes, observe the permissible temperatures and pressures as per EN :1998 specified in Table 5. A maximum operating temperature of 80 C and maximum operating pressure of 4 bar applies for plastic pipe connections, if permitted by the pipe manufacturer. HERZ-3000-thermostatic valves for one-pipe systems are pre-set to 40% of the radiator water quantity. At the radiator side, there are two freely moving union nuts and a flat-seal connection. Optionally, two cone sleeves ( ) for radiator connection thread G 3/4 or two connection nipples ( ) for Rp 1/2 are enclosed with the valve. The flat-seal connection element permits the pipe tolerances of the radiator connection to be offset. In order to protect the flat rubber seals, the freely moving nuts must be tightened only moderately with a 30 mm open-jawed spanner. Field of Application Operating Data HERZ Compression Union Flow Rate in One-Pipe Systems Mounting onto the Radiator HERZ-3000-thermostatic valves can be pre-mounted on the piping. After shutting off both intake and return flow, the system can be filled and pressure-tested. After completion of interior work (painting and decorating work) the thermostat nead can be installaed and the radiator connected. The sealing surfaces pointing upward and the union nut of pre-mounted HERZ-3000-thermostatic valves should be covered with protective plugs until the radiator is mounted. The valve spindle is closed by means of the HERZ-multi-purpose key ( ) or an 8 mm Allen key. When opening the valve, it will be completely open after approximately 3 to 3.5 turns. Pre-Mounting Shutting Off the Return Valve HERZ compression union for copper and thin-walled steel pipes 6275 HERZ compression union with soft seal for copper and thin-walled steel pipes, particularly suitable for hard special steel pipes and pipes with hard-galvanised surfaces HERZ compression union for PE-X-, PB and plastic composite pipes. For pipe dimensions and order numbers refer to the HERZ catalogue or price list. When mounting the compression unions do not use adjustable pliers or any similar tools since this will result in deformation of the union nut. Steel and copper pipes must be properly calibrated and deburred. The use support sleeves is recommended. The thread of the union nut must be lubricated with silicone oil during assembly. Mineral oil would destroy the O-ring of the olives. The mounting instructions enclosed with the compression unions must be followed. The special connection element is installed between the bypass body or connection element and piping for the adaptation of distances between pipes and for radiator adaptation. For details refer to the standard sheet Special Connection Element. Pipe Connections G 3/4 to be ordered separately Mounting of Compression Unions onto the Pipe???? The thermostatic upper part can be removed using the HERZ-changing tool while the system is under pressure: Change the thermostatic upper part to remedy defects, caused by foreign substances such as dirt, welding or soldering residues. In two-pipe systems: retrofitting with thermostatic upper parts with fixed, stepped kv-values or with pre-setting function. This permits the radiator flow rate to be adapted to individual requirements. An O-ring is used as a spindle seal. It is located in a brass chamber which can be changed during operation. The O-ring keeps maintenance requirements to a minimum and permits lasting ease of valve operation. 1. Remove the HERZ-thermostatic head or HERZ-TS-handwheel. 2. Unscrew the O-ring chamber with the O-ring and replace with a new one. During this change use a wrench to hold the upper part. After removal of the thermostatic head or handwheel the valve is completely open and therefore sealed tight towards upstream. However, a few drops of water may leak out. 3. For re-assembly follow the above steps in reverse sequence. Order number for HERZ-TS-O-Ring-Set: Changing the Thermostatic Upper Part Spindle Seal Changing the O-Ring Chamber 2

3 If the radiator and the thermostatic valve are covered (e.g. by curtains or panelling) this will cause heat accumulation zones in which the thermostat cannot sense the room temperature properly and consequently is not in a position to control it. In these cases, use HERZ-thermostats with remote sensor or remote control. For details on HERZ-thermostats refer to the respective product standard sheets. Important for Installation In the exceptional case that the valve is not equipped with a HERZ-thermostatic head, the HERZ-TS handwheel is used to replace the screw cap. During installation, follow the instructions enlosed with the handwheel. HERZ-TS-Handwheel The screw cap serves for operation during the installation phase (pipe flushing). The thermostatic valve is formed by removing the screw cap and screwing in the thermostatic head without draining the heating system. Setting the nominal lift with the screw cap: On the knurled part of the circumference of the screw cap there are two setting marks (webs) in alignment with the + and marks. 1. Close the valve by turning the screw cap clockwise. 2. Mark the position corresponding to the setting mark Turn the screw cap anti-clockwise until the setting mark is at the position marked under item 2. HERZ Thermostatic Valve Nominal Lift After the end of the heating period open the valve completely by turning it in an anti-clockwise direction to prevent dirt deposits at the valve seat. Summer??? p-deviation One-Pipe Systems (Ring) Two-Pipe Systems 1 K kv-values 2 K K open Radiator percentage flow rate Radiator Percentage Flow Rate Determined by One-Pipe Valve Flow rate [%] 1 K 2 K 3 K p-deviation open Spacer block for distances between pipe centres 50 mm Special connection element, intersection element G 3/ Connection elbow HERZ Multi-purpose key HERZ-TS-90-Assembly key HERZ changing tool for thermostatic upper parts HERZ-TS-90 Handwheel, Series 7000 with pre-setting and locking functions HERZ-TS-90 Handwheel, Series 900 Design. Accessories Hand wheels cone sleeves for radiator connection G 3/ connection nipples for radiator connection Rp 1/ Flat seal (set = 10 seals) Thermostatic upper part for two pipe systems Thermostatic upper part for one pipe systems HERZ-TS O-ring set Spare parts 3

4 HERZ-Standard Diagram HERZ-3000 in Two-Pipe Systems Art. Nr. Connection Elements Dim. R = 1/2" Valve dimensioning [ p] has to be performed in accordance with the VDMA-Instruction Sheet for Planning and Hydraulic Balancing of Heating Systems with Thermostatic Radiator Valves. k v -value open Pressure drop Standard flow rate qm We reserve the right to make modifications.

5 HERZ-Standard Diagram HERZ-3000 in One-Pipe Systems Art. Nr. Bypass Bodies Dim. R = 1/2" Valve dimensioning [ p] has to be performed in accordance with the VDMA-Instruction Sheet for Planning and Hydraulic Balancing of Heating Systems with Thermostatic Radiator Valves. k v -value open Pressure drop Standard flow rate qm in the pipe ring We reserve the right to make modifications.

HERZ TS-3000 HERZ HERZ Armaturen A-1230 Vienna Richard-Strauss-Straße 22

HERZ TS-3000 HERZ HERZ Armaturen A-1230 Vienna Richard-Strauss-Straße 22 HERZ TS-3000 HERZ-3000 Connection system for radiators Thermostatic valve and shut-off return valve Standard sheet for 3691-3694 3791 3794 Issue 0702 G 3/4 Dimensions in mm 1 3002 31 Connection nipples

More information

HERZ-Thermostatic and Return Valves. DE LUXE Edition 1000 (0999) HERZ Armaturen. Standard Sheet for DE LUXE. Richard-Strauss-Straße 22 A-1230 Wien

HERZ-Thermostatic and Return Valves. DE LUXE Edition 1000 (0999) HERZ Armaturen. Standard Sheet for DE LUXE. Richard-Strauss-Straße 22 A-1230 Wien HERZ-Thermostatic and Return Valves Standard Sheet for DE LUXE Edition 1000 (0999) This series consists of HERZ radiator thermostats, HERZ-TS-90 thermostatic valves and HERZ return valves. These components

More information

HERZ-DR-T-90. Radiator Control Valves with Pre-Setting Function by Means of Double Cone, Suitable for Conversion to Thermostatic Operation. H max.

HERZ-DR-T-90. Radiator Control Valves with Pre-Setting Function by Means of Double Cone, Suitable for Conversion to Thermostatic Operation. H max. Radiator Control Valves with Pre-Setting Function by Means of Double Cone, Suitable for Conversion to Thermostatic Operation Standard Sheet for 6823/ 6824 Edition 1000 (0999) 6823 6824 Special Models 1

More information

CALIS-TS-3-D. HERZ Armaturen. Standard Sheet for 7745, 7746, 7761 Edition 0700 (0999) Three-Way Valves in 3-D Design for One-Pipe Systems

CALIS-TS-3-D. HERZ Armaturen. Standard Sheet for 7745, 7746, 7761 Edition 0700 (0999) Three-Way Valves in 3-D Design for One-Pipe Systems -3-D Three-Way Valves in 3-D Design for One-Pipe Systems Standard Sheet for 7745, 7746, 7761 Edition 0700 (0999) Dimensions in mm 7761 C H -E 7745 7746 C H H = Height HEZ-thermostat 37,5 Ø Flow-T-Piece

More information

Connection set. Radiator connection set for thermostatic and manual operation Ø 12

Connection set. Radiator connection set for thermostatic and manual operation Ø 12 Connection set Radiator connection set for thermostatic and manual operation Data sheet for 1 7650 00 Issue 0405 Control valves Connection pipe Ø 12 L L = 600 1 7650 00 L = 1000 1 7650 01 Bypass bodies

More information

TS RD 7761 RD, 7761 RD

TS RD 7761 RD, 7761 RD 1/2 HERZ Calis TS RD three way valve HERZ Calis TS RD 100% three-way valve for heating and cooling Datasheet for 1 7761 RD, Issue 0716 Dimensions in mm Order number Dimension R A B C kvs dp (bar) maximum

More information

Distributors for Floor Heating Systems

Distributors for Floor Heating Systems Distributors for Floor Heating Systems Rod-type distributor, Dimension 1" Standard Sheet for 8531/8532 Edition 0200 (0799) Rod-type distributor sets with shutoff- and thermostatic upper parts Rod-type

More information

HERZ Regulating valve 4002

HERZ Regulating valve 4002 HERZ Regulating valve 4002 Data sheet 4002, Issue 0214 Dimensions in mm B1 B2 1 4002 41 1 4002 61 1 4002 42 1 4002 62 1 4002 43 1 4002 63 1 4002 44 1 4002 64 1 4002 45 1 4002 65 1 4002 46 1 4002 66 DN

More information

Mikrotherm. Manual Radiator Valves With presetting

Mikrotherm. Manual Radiator Valves With presetting Mikrotherm Manual Radiator Valves With presetting IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Mikrotherm Mikrotherm The Mikrotherm manual radiator valve is used in warm water pump heating systems,

More information

HERZ Differential Pressure Control Valve 4002

HERZ Differential Pressure Control Valve 4002 HERZ Differential Pressure Control Valve 4002 Data sheet 4002, Issue 0118 Dimensions in mm B1 B2 1 4002 41 1 4002 61 1 4002 71 1 4002 42 1 4002 62 1 4002 72 1 4002 43 1 4002 63 1 4002 73 1 4002 44 1 4002

More information

Control valves for floor heating systems. Floor Heating Manifolds

Control valves for floor heating systems. Floor Heating Manifolds Control valves for floor heating systems Floor Heating Manifolds IMI HEIMEIER / Floor Heating Control / Control valves for floor heating systems Control valves for floor heating systems Supply control

More information

Thermostatic valves with radiator connection systems

Thermostatic valves with radiator connection systems Multilux Eclipse Thermostatic valves with radiator connection systems with two-point connection for two-pipe heating systems, with automatic flow limitation IMI HEIMEIER / Thermostatic heads and Radiator

More information

Say heating. Say Herz. HERZ-Supply Engineering

Say heating. Say Herz. HERZ-Supply Engineering HERZ-Supply Engineering Medium Temperature Control Pressure Control Fittings Control Fittings Lock Shields and Isolators Accessories Spare Parts Say heating. Say Herz. HERZ Valves UK Progress House [ Moorfield

More information

For reversed flow direction. Thermostatic Radiator Valves Thermostatic valve body with and without presetting

For reversed flow direction. Thermostatic Radiator Valves Thermostatic valve body with and without presetting For reversed flow direction Thermostatic Radiator Valves Thermostatic valve body with and without presetting IMI HEIMEIER / Thermostatic Heads & Radiator Valves / For reversed flow direction For reversed

More information

Standard C. Thermostatic Radiator Valve Thermostatic valve body with reversed direction of operation

Standard C. Thermostatic Radiator Valve Thermostatic valve body with reversed direction of operation Standard C Thermostatic Radiator Valve Thermostatic valve body with reversed direction of operation IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Standard C Standard C The Standard C thermostatic

More information

V-exact II. Thermostatic Radiator Valves Thermostatic valve body with stepless precision presetting

V-exact II. Thermostatic Radiator Valves Thermostatic valve body with stepless precision presetting V-exact II Thermostatic Radiator Valves Thermostatic valve body with stepless precision presetting IMI HEIMEIER / Thermostatic Heads & Radiator Valves / V-exact II V-exact II V-exact II thermostatic valve

More information

Thermostatic three-way valve body. Thermostatic Radiator Valves without presetting, with automatic bypass control

Thermostatic three-way valve body. Thermostatic Radiator Valves without presetting, with automatic bypass control Thermostatic three-way valve body Thermostatic Radiator Valves without presetting, with automatic bypass control IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Thermostatic three-way valve body

More information

regulux Radiator lockshield with drain-off facility Pressurisation & Water Quality Balancing & control thermostatic control engineering ADVANTAge

regulux Radiator lockshield with drain-off facility Pressurisation & Water Quality Balancing & control thermostatic control engineering ADVANTAge regulux Radiator lockshield with drain-off facility Pressurisation & Water Quality Balancing & control thermostatic control engineering ADVANTAge Regulux Description Separate presetting cone for consistent

More information

Calypso TRV-3. (for the Nordic countries) Thermostatic radiator valves With presetting

Calypso TRV-3. (for the Nordic countries) Thermostatic radiator valves With presetting Calypso TRV-3 (for the Nordic countries) Thermostatic radiator valves With presetting IMI TA / Thermostatic heads and Radiator valves / Calypso TRV-3 (for the Nordic countries) Calypso TRV-3 (for the Nordic

More information

Eclipse. Thermostatic Radiator Valves Thermostatic radiator valve with automatic flow limitation

Eclipse. Thermostatic Radiator Valves Thermostatic radiator valve with automatic flow limitation Eclipse Adaptative Flow Control Thermostatic Radiator Valves Thermostatic radiator valve with automatic flow limitation IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Eclipse Eclipse The thermostatic

More information

Standard. Thermostatic Radiator Valves Thermostatic valve body without presetting

Standard. Thermostatic Radiator Valves Thermostatic valve body without presetting Standard Thermostatic Radiator Valves Thermostatic valve body without presetting IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Standard Standard The Standard thermostatic valve bodies are used

More information

Regulux. Return Lockshield Radiator lockshield with consistent presetting and drain-off facility

Regulux. Return Lockshield Radiator lockshield with consistent presetting and drain-off facility Regulux Return Lockshield Radiator lockshield with consistent presetting and drain-off facility IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Regulux Regulux The Regulux is used in warm water pump

More information

Calypso exact. Thermostatic Radiator Valves With stepless precision presetting

Calypso exact. Thermostatic Radiator Valves With stepless precision presetting Calypso exact Thermostatic Radiator Valves With stepless precision presetting IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Calypso exact Calypso exact Calypso exact thermostatic valve bodies are

More information

TRV pack Eclipse. Thermostatic valves with radiator connection systems Thermostatic raditor valve with automatic flow control, head and lockshield

TRV pack Eclipse. Thermostatic valves with radiator connection systems Thermostatic raditor valve with automatic flow control, head and lockshield TRV pack Eclipse Thermostatic valves with radiator connection systems Thermostatic raditor valve with automatic flow control, head and lockshield IMI HEIMEIER / Thermostatic heads and Radiator valves /

More information

Standard. thermostatic valve body without presetting

Standard. thermostatic valve body without presetting Standard thermostatic valve body without presetting Pressurisation & Water Quality Balancing & Control Thermostatic Control EnGInEErInG advantage The standard thermostatic valve bodies are used in two-pipe

More information

Eclipse F. Thermostatic Radiator Valves Thermostatic radiator valve with automatic flow limitation

Eclipse F. Thermostatic Radiator Valves Thermostatic radiator valve with automatic flow limitation Eclipse F Adaptative Flow Control Thermostatic Radiator Valves Thermostatic radiator valve with automatic flow limitation IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Eclipse F Eclipse F The thermostatic

More information

Standard. Thermostatic Radiator Valves Thermostatic valve body without presetting

Standard. Thermostatic Radiator Valves Thermostatic valve body without presetting Standard Thermostatic Radiator Valves Thermostatic valve body without presetting IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Standard Standard The Standard thermostatic valve bodies are used

More information

Thermostatic valve bodies

Thermostatic valve bodies Thermostatic valve bodies for all thermostatic heads and actuators Pressurisation & Water Quality Balancing & Control Thermostatic Control ENGINEERING ADVANTAGE ThermosTaTic valve bodies Table of contents

More information

Installation and operating instructions

Installation and operating instructions Installation and operating instructions To be precise. Installation and operating instructions Table of contents General notes Page Thermostatic valve 3 Faults Causes Remedial action 4 Temperature setting

More information

Standard. Thermostatic Radiator Valves Thermostatic valve body without presetting

Standard. Thermostatic Radiator Valves Thermostatic valve body without presetting Standard Thermostatic Radiator Valves Thermostatic valve body without presetting IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Standard Standard The Standard thermostatic valve bodies are used

More information

Regulux. Radiator lockshield with drain-off facility. To be precise.

Regulux. Radiator lockshield with drain-off facility. To be precise. Radiator lockshield with drain-off facility To be precise. Description Assembly Regulux Closing cap Thrust piece HEIMEIER radiator lockshield for shutting off, presetting, draining off and filling. Separate

More information

Thermostatic valve bodies

Thermostatic valve bodies Thermostatic valve bodies for single pipe heating systems Thermostatic valves with radiator connection systems IMI HEIMEIER / Thermostatic heads and Radiator valves / Thermostatic valve bodies for single

More information

Vekotrim. Valves for radiators with integrated valve Double connection fitting with shut-off ball valves for radiators with integrated valves

Vekotrim. Valves for radiators with integrated valve Double connection fitting with shut-off ball valves for radiators with integrated valves Vekotrim Valves for radiators with integrated valve Double connection fitting with shutoff ball valves for radiators with IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Vekotrim Vekotrim The Vekotrim

More information

E-Z Valve. Thermostatic valves with radiator connection systems For single and two-pipe heating systems

E-Z Valve. Thermostatic valves with radiator connection systems For single and two-pipe heating systems E-Z Valve Thermostatic valves with radiator connection systems For single and two-pipe heating systems IMI HEIMEIER / Thermostatic heads and Radiator valves / E-Z Valve E-Z Valve E-Z Valve with immersion

More information

Multilux 4-Eclipse-Set

Multilux 4-Eclipse-Set Multilux -Eclipse-Set Design-Edition with two-point connection, angle and straight type, for R / and connection, with automatic flow limitation IMI HEIMEIER / Design-Edition / Multilux -Eclipse-Set Multilux

More information

thermostatic valve body with stepless precision presetting

thermostatic valve body with stepless precision presetting Thermostatic Radiator Valves V-exact II thermostatic valve body with stepless precision presetting Pressurisation & Water Quality Balancing & Control Thermostatic Control ENGINEERING AVANTAGE V-exact II

More information

General System Layout Sketch

General System Layout Sketch General System Layout Sketch EZ-37 Solar Panels PV panel Glycol Fill Valve Expansion Tank ` 1 Introduction This document describes how to install a Heliatos GH type solar water heating system. These systems

More information

teide termo plus+ HEATING SERIES SCOPE THERMOSTATIC VALVES SERVICE CONDITIONS COMPONENTS TECHNICAL SHEET 07/2017 IP20060 PAG. 1/9

teide termo plus+ HEATING SERIES SCOPE THERMOSTATIC VALVES SERVICE CONDITIONS COMPONENTS TECHNICAL SHEET 07/2017 IP20060 PAG. 1/9 HEATING SERIES QUALITY BY TRADITION teide termo plus+ TECHNICAL SHEET 07/2017 IP20060 SCOPE The thermostatic valves and heads from TEIDE TERMO PLUS series can be used in individual or collective heating

More information

MINIATURE THERMOSTATIC VALVE

MINIATURE THERMOSTATIC VALVE SS-TH500-1/2 Features: Ability to pre-select water temperature thus conserving water Compensates for water pressure fluctuations preventing scalding Safety button at 100 F prevents accidental scalding

More information

Dynalux. Floor Heating Manifolds Underfl oor heating circuit manifold

Dynalux. Floor Heating Manifolds Underfl oor heating circuit manifold Dynalux Floor Heating Manifolds Underfl oor heating circuit manifold IMI HEIMEIER / Floor Heating Control / Dynalux Dynalux Dynalux adjusts the flow rate in the individual heating circuits directly in

More information

Audi-Larm Audible Alarm

Audi-Larm Audible Alarm Audi-Larm Audible Alarm MAINTENANCE AND REPAIR TAL 1706 (L) Rev. 7 MSA 2017 Prnt. Spec. 10000005389(I) Mat. 10093084 Doc. 10093084 REPLACEMENT KITS AND PARTS LIST TAL 1706 (L) Rev. 7-10093084 2 Exploded

More information

INSTALLTION FOR THERMOSTATIC VALVES

INSTALLTION FOR THERMOSTATIC VALVES SS-TH1000 ½ THERMOSTATIC VALVE SS-TH3000 ¾ THERMOSTATIC VALVE SS-TH2000 ½ THERMOSTATIC VALVE WITH BUILT IN VOLUME CONTROL SS-TH4000 ¾ THERMOSTATIC VALVE WITH BUILT IN VOLUME CONTROL Features: Ability to

More information

THERMOSTATIC EXPANSION VALVES AND THERMOSTAT CONTROL DEVICES

THERMOSTATIC EXPANSION VALVES AND THERMOSTAT CONTROL DEVICES FUNCTION Thermostatic expansion valves are used to regulate and cut-off the flow of the heat transfer fluid that circulates inside airconditioning system terminals (radiators, fan coils, etc.). Thermostat

More information

INSTALLATION FOR THERMOSTATIC VALVES

INSTALLATION FOR THERMOSTATIC VALVES SS-TH1000 1/2 Thermostatic Valve SS-TH3000 3/4 Thermostatic Valve SS-TH2000 1/2 Thermostatic Valve with built in volume control SS-TH4000 3/4 Thermostatic Valve with built in volume control Features: Ability

More information

THERMOSTATIC EXPANSION VALVES AND THERMOSTAT CONTROL DEVICES

THERMOSTATIC EXPANSION VALVES AND THERMOSTAT CONTROL DEVICES FUNCTION Thermostatic expansion valves are used to regulate and cut-off the flow of the heat transfer fluid that circulates inside airconditioning system terminals (radiators, fan coils, etc.). Thermostat

More information

THERMOSTATIC SINGLE-PIPE AND DOUBLE-PIPE VALVES

THERMOSTATIC SINGLE-PIPE AND DOUBLE-PIPE VALVES ST.07.05.00 THERMOSTIC SINGLE-PIPE AND DOUBLE-PIPE VALVES 1. Art.1420 THERMOSTIC SINGLE-PIPE VALVE Single-pipe valves allow manual, thermostatic or thermo-electric regulation. Separation of the lockshield

More information

Thermostatic mixing valves with interchangeable cartridges

Thermostatic mixing valves with interchangeable cartridges www.caleffi.com R37. Thermostatic mixing valves with interchangeable cartridges Installation, commissioning and servicing instructions 3 Series Function The thermostatic mixing valve is used in systems

More information

Design-Edition. Design-Edition Thermostatic valves and lockshields, sets

Design-Edition. Design-Edition Thermostatic valves and lockshields, sets Design-Edition Design-Edition Thermostatic valves and lockshields, sets IMI HEIMEIER / Design-Edition / Design-Edition Design-Edition The sets are an elegant solution for e. g. design radiators. A sublime

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Stour Thermostatic Exposed Shower Valve Single Outlet, Rigid Riser, Fixed Shower Arm & Soap Basket - BF2S Options: Burlington has a shower head of 3 different sizes for your selection.

More information

Parts & Material Included

Parts & Material Included O² Hydro Well System Installation, Use & Care Guide Parts & Material Included 1. Funnel 11. Drain Line 21. Air Head 2. Media Tank Distributer Tube 12. Air Release 22. Drain Fitting 3. Air Tank Distributer

More information

SS-THVD2-1/2 THERMOSTATIC VALVE WITH 2 WAY DIVERTER SS-THVD3-1/2 THERMOSTATIC VALVE WITH 3 WAY DIVERTER

SS-THVD2-1/2 THERMOSTATIC VALVE WITH 2 WAY DIVERTER SS-THVD3-1/2 THERMOSTATIC VALVE WITH 3 WAY DIVERTER SS-THVD2-1/2 THERMOSTATIC VALVE WITH 2 WAY DIVERTER SS-THVD3-1/2 THERMOSTATIC VALVE WITH 3 WAY DIVERTER Features: Ability to pre-select water temperature thus conserving water Paraffin wax element maintains

More information

Multibox 4. Floor Heating Controller Flush individual room control for floor heating systems with supply shut-off

Multibox 4. Floor Heating Controller Flush individual room control for floor heating systems with supply shut-off Multibox 4 Floor Heating Controller Flush individual room control for floor heating systems with supply shut-off IMI HEIMEIER / Floor Heating Control / Multibox 4 Multibox 4 RTL and K-RTL and K-RTL is

More information

Safety. Operating instructions Ionization pilot burners ZAI, ZMI, ZKIH DANGER. Contents WARNING CAUTION Edition 12.11

Safety. Operating instructions Ionization pilot burners ZAI, ZMI, ZKIH DANGER. Contents WARNING CAUTION Edition 12.11 050560 Edition. D F NL I E DK S N P GR TR CZ PL RUS H www.docuthek.com Operating instructions Ionization pilot burners,, Translation from the German 0 Elster GmbH Contents Checking the usage.....................

More information

Flush individual room control for floor heating systems

Flush individual room control for floor heating systems Multibox Flush individual room control for floor heating systems Pressurisation & Water Quality Balancing & Control Thermostatic Control ENGiNEERiNG ADVANTAGE Multibox is used for decentralized control

More information

Problem-solvers The Radiator Solution Range

Problem-solvers The Radiator Solution Range Simplex Problem-solvers Problem-solvers The Radiator Solution Range I Height and depth compensation I Continuously swivelling connections I Reversal of supply and return flow I Quick and clean radiator

More information

Technical Data TYPE T14 & T14D TEMPERATURE PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4511A T14 PILOT

Technical Data TYPE T14 & T14D TEMPERATURE PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4511A T14 PILOT Technical Data SD 4511A SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY 12586-2035 TYPE T14 & T14D TEMPERATURE PILOT PRINTED IN U.S.A. SD 4511A/9811 5 13 /16 D 4 7 /8 1 13 /16 T14 PILOT

More information

Thermostatic Valve and Trim

Thermostatic Valve and Trim ML8950-xx Thermostatic Valve and Trim Description Installation instructions Trim and PL8950 valve Brass lever handles and face plate Standards ASME A112.18.1 Listed IAPMO / UPC & CUPC ADA Accessibility

More information

Multibox. Floor Heating Controller Flush individual room control for floor heating systems

Multibox. Floor Heating Controller Flush individual room control for floor heating systems Multibox Floor Heating Controller Flush individual room control for floor heating systems IMI HEIMEIER / Floor Heating Control / Multibox Multibox K, RTL and K-RTL Multibox K, RTL and K-RTL is used for

More information

GENERAL CATALOGUE MICROMETRIC, THERMOSTATIC VALVES THERMOSTATIC VALVES MANUAL VALVES LOCKSHIELDS ACCESSORIES AND SPARE PARTS

GENERAL CATALOGUE MICROMETRIC, THERMOSTATIC VALVES THERMOSTATIC VALVES MANUAL VALVES LOCKSHIELDS ACCESSORIES AND SPARE PARTS GENERAL CATALOGUE MICROMETRIC, TERMOSTATIC VALVES TERMOSTATIC VALVES MANUAL VALVES LOCKSIELDS ACCESSORIES AND SPARE PARTS SUMMARY 1. USE 2. MICROMETRIC TERMOSTATIC VALVES 3. TECNICAL DATA 3. MATERIALS

More information

SOLUTIONS GUIDE. For total efficiency

SOLUTIONS GUIDE. For total efficiency 2014-2015 SOLUTIONS GUIDE For total efficiency THERMOSTATIC RADIATOR HEADS Comap Thermostatic heads have been counted amongst the best sellers in Europe for decades, thanks to their high manufacturing

More information

2 DESCRIPTION OF SYSTEM COMPONENTS

2 DESCRIPTION OF SYSTEM COMPONENTS 2 DESCRIPTION OF SYSTEM COMPONENTS Buderus Panel Radiators Buderus Solidoflux N panel radiators are manufactured from.049 (1.25 mm) thick steel panels. They consist of water-filled steel welded radiative

More information

V2075, V2077 Flowshare Valve THERMOSTATIC TWO-WAY FLOWSHARE VALVE

V2075, V2077 Flowshare Valve THERMOSTATIC TWO-WAY FLOWSHARE VALVE V2075, V2077 Flowshare Valve THERMOSTATIC TWO-WAY FLOWSHARE VALVE Application Thermostatic flowshare valves control the output of radiators in vertical one-pipe heating systems. Heating water not required

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Thermostatic Three Tap Hole tap, with pop up (excluding tap heads & base) - T26 Option 1: urlington has 3 different style handle for your selection. Claremont Anglesey irkenhead

More information

Thermostatic mixing valves with replaceable cartridge for centralized systems

Thermostatic mixing valves with replaceable cartridge for centralized systems Thermostatic mixing valves with replaceable cartridge for centralized systems series REGISTERED BS EN ISO 9: Cert. n FM UNI EN ISO 9: Cert. n / N Replaces /9 N Function The thermostatic mixing valve is

More information

Minimalist Bottom Outlet Thermostatic Bar Shower. Telephone Product Specification

Minimalist Bottom Outlet Thermostatic Bar Shower. Telephone Product Specification Product Specification ~ Minimum Working Pressure 0.5 bar ~ Maximum Working Pressure 4.0 bar ~ Cold Water Supply Temp 4-20 c ~ Hot Water Supply Temp 55-85 c ~ Fixing Centres 150mm +/- 20mm ~ Outlet size

More information

IMI Heimeier Kit Hydroca ble

IMI Heimeier Kit Hydroca ble IMI Heimeier Kit Hydroca ble Thermostatic valves with radiator connection systems Thermostatic valve and lockshield with tube-bend for the installation as angle form or axial form with press- or sliding

More information

Three-way reversing valve

Three-way reversing valve Three-way reversing valve For heating and cooling systems Pressurisation & Water Quality Balancing & Control thermostatic Control engineering avantage Three-way reversing valve for the distribution of

More information

Owner s Guide and Installation Manual

Owner s Guide and Installation Manual For Your Records and Warranty Assistance For reference, also attach your receipt or a copy of your receipt to the manual. Model Name Type 2 Models Owner s Guide and Installation Manual Model No. Date Purchased

More information

Unibox Individual room temperature control and limitation of return temperature in surface heating systems

Unibox Individual room temperature control and limitation of return temperature in surface heating systems 4 3 2 4 4 3 2 Unibox Individual room temperature control Technical information Tender specification: Oventrop Unibox for temperature balance of floor and wall surface by limiting the return temperature

More information

FLOWRETT, TA-UNI. Thermostatic valves with radiator connection system One-pipe

FLOWRETT, TA-UNI. Thermostatic valves with radiator connection system One-pipe FLOWRETT, TA-UNI Thermostatic valves with radiator connection system One-pipe IMI TA / Thermostatic heads and Radiator valves / FLOWRETT, TA-UNI FLOWRETT, TA-UNI Compatible with most radiators on the market,

More information

TOWEL WARMERS ARE HEAVY! WE RECOMMEND THAT TWO PEOPLE INSTALL THE TOWEL WARMER!

TOWEL WARMERS ARE HEAVY! WE RECOMMEND THAT TWO PEOPLE INSTALL THE TOWEL WARMER! 1. Please follow instructions carefully to ensure that the towel warmer is properly attached to the wall or floor. FAILURE TO FOLLOW THESE STEPS COULD RESULT IN PROBLEMS. 2. Do not use an abrasive or chlorine-based

More information

RA 2000 Series RA 15/6T & TB Conversion Valve

RA 2000 Series RA 15/6T & TB Conversion Valve RA 2000 Series RA 15/6T & TB Conversion Valve Applications: RA15/6T Internal bypass allowing for series piping to the radiators/baseboards. This series piping provides continuous flow but the supply water

More information

Instructions. Certifications Brass w/built-in Stop Valve. Pressure Balance Shower Valve. Tools Required. Important Points.

Instructions. Certifications Brass w/built-in Stop Valve. Pressure Balance Shower Valve. Tools Required. Important Points. Instructions Tools Required Adjustable Wrench Groove Joint Pliers Pipe Wrench Phillips Screwdriver Pipe Tape or Pipe Thread Compound Safety Tips If you solder the joints during installation, the seats,

More information

APEX Water Filters MODEL RO 5. Treat your body to pure goodness with Apex filtered water INSTRUCTION MANUAL. pure water in every drop

APEX Water Filters MODEL RO 5. Treat your body to pure goodness with Apex filtered water INSTRUCTION MANUAL. pure water in every drop APEX Water Filters pure water in every drop MODEL RO 5 INSTRUCTION MANUAL Treat your body to pure goodness with Apex filtered water A Water supply adapter valve B Cold water shut-off valve C Hot water

More information

Installation and Operation Instructions K36E Modular Heating Circuit - DN 25 Boiler charging set

Installation and Operation Instructions K36E Modular Heating Circuit - DN 25 Boiler charging set PAW GmbH & Co. KG Böcklerstr. 11, D-31789 Hameln, Germany Phone: +49-5151-9856-0, Fax: +49-5151-9856-98 Email: info@paw.eu, Web: www.paw.eu Installation and Operation Instructions K36E Modular Heating

More information

Inta City Concealed Shower Mixing Valve CT80010CP

Inta City Concealed Shower Mixing Valve CT80010CP Inta City Concealed Shower Mixing Valve CT80010CP Installation and Maintenance Instructions In this procedure document we have endeavoured to make the information as accurate as possible. We cannot accept

More information

541D19 SERIES. Technical Manual. A Division of Aquion Partners L.P.

541D19 SERIES. Technical Manual. A Division of Aquion Partners L.P. 541D19 SERIES Technical Manual A Division of Aquion Partners L.P. Table of Contents Introduction... Page 1 Technical Specifications... Page 2 Flow Diagrams... Page 3 Injector & Flow Control Selection Injector...

More information

Valid from

Valid from Range 203 / 204 Valid from 0.04.203 HERZ Armaturen Ges.m.b.H. A-230 Vienna, Austria Richard-Strauss-Straße 22 Telephone: +43/(0)/66 26 3-0 Fax: +43/(0)/66 26 3-227 e-mail: office@herz.eu www.herz.eu General

More information

Mixermate Instructions Shower [Product Numbers MS001, MS002, MS003, MS004, MS005, MS006, MS007.]

Mixermate Instructions Shower [Product Numbers MS001, MS002, MS003, MS004, MS005, MS006, MS007.] Mixermate Instructions Shower 2018 www.mixermate.com.au [Product Numbers MS001, MS002, MS003, MS004, MS005, MS006, MS007.] Page 1/5 Shower Installation Instructions 2018 What you will need. Tape measure.

More information

RA15/6T & TB Conversion Valve

RA15/6T & TB Conversion Valve Applications: continue on. This provides continuous flow, but inherent to series piping the supply water temperature will decrease as it flows through the system and when it mixes with return water from

More information

Intatherm Safe Touch Basin Tap IT1008CP

Intatherm Safe Touch Basin Tap IT1008CP Intatherm Safe Touch Basin Tap IT1008CP Installation and Maintenance Instructions In this procedure document we have endeavoured to make the information as accurate as possible. We cannot accept any responsibility

More information

INDIVIDUAL HEATING. Installation Manual e Skirting Heating Classic. Skirting Heating Delta. HEATING. COOLING. COMFORT.

INDIVIDUAL HEATING. Installation Manual e Skirting Heating Classic. Skirting Heating Delta. HEATING. COOLING. COMFORT. www.variotherm.at INDIVIDUAL HEATING Skirting Heating Classic. Skirting Heating Delta. Installation Delta HEATING. COOLING. COMFORT. Classic Installation Manual e22111 Page 2 Table of Contents INDIVIDUAL

More information

V2880, Therafix Design Thera Design Edition - H-Block with TRV Insert WITH HIGH QUALITY SURFACE FOR DESIGN RADIATORS

V2880, Therafix Design Thera Design Edition - H-Block with TRV Insert WITH HIGH QUALITY SURFACE FOR DESIGN RADIATORS W GE R MAN Y W GE R MAN Y V2880, Therafix Design Thera Design Edition - H-Block with TRV Insert WITH HIGH QUALITY SURFACE FOR DESIGN RADIATORS Design Angle left Straight W GE R MAN Y Angle right The Therafix

More information

Aquastrom T plus Thermostatic valve with adjustable temperature control range and fixed residual volume flow for circulation pipes

Aquastrom T plus Thermostatic valve with adjustable temperature control range and fixed residual volume flow for circulation pipes Thermostatic valve with adjustable temperature control range Technical information Tender specification: Oventrop thermostatic valve Aquastrom T plus with presetting for circulation pipes. Thermal control

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATI INSTRUCTIS Trent Thermostatic Two Outlet Concealed Shower Valve, Fixed Shower Arm, Handset & Holder with Hose - TF3S Options: urlington has 2 different style handles for your selection, when

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUTIONS 20007013160 Important We recommend that this product is installed by a qualified professional plumber who is certified by NVQ (National Vocational Qualification) or SNVQ (Scottish

More information

Multibox. Flush Individual Room Control for Floor Heating Systems. To be precise.

Multibox. Flush Individual Room Control for Floor Heating Systems. To be precise. Flush Individual Room Control for Floor Heating Systems To be precise. Contents Page Multibox K, Multibox RTL and Multibox K-RTL Description Construction Application 4 Temperature Setting 4 Function Article

More information

A B A B4

A B A B4 TM TM SERVICE INSTRUCTIONS Thermo-Aire Heater Kits and Air-Heater Assemblies 383808-A4 383808-B4 383880-A4 383880-B4 DESCRIPTION The Thermo-Aire Heater is used in situations where oils of heavier viscosity

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS Tay Thermostatic Bath Shower Mixer Deck Mounted with Swivel Shower Arm - T2DS Options: INSTALLATION INSTRUCTIONS Burlington has 2 different style handles for your selection, when using these additional

More information

13-1. Temperature Regulator

13-1. Temperature Regulator -1 Step 0 Type/Structure/Features Please refer to this for type, structure and features of. Step 1 Selection Please look at the ID chart to choose the right products depending on the intended uses. Details

More information

Avensys Avensys FIN EST SLO RUS UAE

Avensys Avensys FIN EST SLO RUS UAE 34 037 Avensys Avensys GB D...1...5 I...5 N...9 GR...13 TR...17 BG...21 RO...25 GB...2 NL...6 FIN...10 CZ...14 SK...18 EST...22 CN...26 F...3 S...7 PL...11 H...15 SLO...19 LV...23 RUS...27 E...4 DK...8

More information

Thermostatic shower valve with 2 way diverter, brass faceplate and handles - V51

Thermostatic shower valve with 2 way diverter, brass faceplate and handles - V51 Thermostatic shower valve with 2 way diverter, brass faceplate and handles - V51 Important We recommend that this product is installed by a qualified professional plumber who is certified by NVQ (National

More information

Owner s Guide and Installation Manual

Owner s Guide and Installation Manual For Your Records and Warranty Assistance For reference, also attach your receipt or a copy of your receipt to the manual. Model Name Type 8 Models Owner s Guide and Installation Manual Model No. Catalog

More information

DIRTMAG dirt separator with magnet, adjustable for vertical or horizontal pipe

DIRTMAG dirt separator with magnet, adjustable for vertical or horizontal pipe DIRTMAG dirt separator with magnet, adjustable for vertical or horizontal pipe Copyright 206 Caleffi NA0322.02 www.caleffi.com NA5453 Series Installation, commissioning and servicing instructions Function

More information

TK-1801, TK-1811 TK-1801, TKR-1811

TK-1801, TK-1811 TK-1801, TKR-1811 TK-1801, TK-1811 TK-1801, TKR-1811 Pneumatic Zero Energy Band Room Thermostats General Instructions APPLICATION For proportional control of pneumatically-operated sequenced heating and cooling valves and/or

More information

Operating Manual. Model: Float-Controlled Condensate Trap, PN Safety instructions. 2 General description and usage

Operating Manual. Model: Float-Controlled Condensate Trap, PN Safety instructions. 2 General description and usage Model: 1090 1 Safety instructions Float-Controlled Condensate Trap, PN 16 1.1 Proper use Any improper use, intervention in the design and deviation from the design data automatically lead to termination

More information

SAN RAPHAEL PRESSURE LITE VITREOUS CHINA SIPHON JET TOILET

SAN RAPHAEL PRESSURE LITE VITREOUS CHINA SIPHON JET TOILET SAN RAPHAEL PRESSURE LITE VITREOUS CHINA SIPHON JET TOILET BEFORE YOU BEGIN HOW TO USE THESE INSTRUCTIONS Please read these instructions carefully to familiarize yourself with the required tools, materials,

More information

Installation Guide ASME A ANSI A117.1 CUPC / IAPMO LISTED / ADA COMPLIANT. Engineering Excellence

Installation Guide ASME A ANSI A117.1 CUPC / IAPMO LISTED / ADA COMPLIANT. Engineering Excellence ngineering Excellenc Engineering Excellence Installation Guide Single Handle Tub & Shower Trim Set: 4LG100T* 4AM100T* 4BR310T* 4LG300T* 4AM200T* 4BR410T* 4LG400T 4BL100T* 4AM300T* 4BR120T 4BL200T* 4AM400T*

More information

Model: 1100 Float-Controlled Condensate Trap, PN 25

Model: 1100 Float-Controlled Condensate Trap, PN 25 1 Safety instructions Model: 1100 Float-Controlled Condensate Trap, PN 25 1.1 Proper use Any improper use, intervention in the design and deviation from the design data automatically lead to termination

More information

TECHNICAL DATA. Wet 26a. February 22, 2009

TECHNICAL DATA. Wet 26a. February 22, 2009 February 22, 2009 Wet 26a 1. DESCRIPTION The Viking Alarm Check Valve serves as a check valve by trapping pressurized water above the clapper and preventing reverse flow from sprinkler piping. The valve

More information