Radiation-based measurement Detectors
|
|
- Basil Glenn
- 5 years ago
- Views:
Transcription
1 Radiation-based measurement Detectors Overview 190 Detectors 192 Accessory 200
2 Radiation-based measurement - Detectors PROTRAC Radiation-based detector for level, density and mass flow measurement Measuring principle Extreme temperatures, high process pressures and complicated mounting conditions the radiation-based measurement by means of gamma rays delivers precise and reliable results even in most difficult applications. The emitted gamma rays are damped when penetrating the medium. The detector receiving the rays at the opposite side of the vessel, calculates a measured value out of their strength. Application level measurement With PROTRAC levels and limit heights are detected contactlessly. Since the measuring facility is mounted on the outside of the vessel, the measuring result is not influenced by physical and chemical properties of the measured product. In addition, measurements on pressurized vessels or on vessels with agitators can be realised without problems. For different vessel forms and sizes, various detector versions are offered which are also cascadable for use on very huge vessels. Application density measurement The non-contact, continuous density and concentration measurement of liquids and bulk solids is suitable for pipelines with a diameter from 50 mm up to more than 800 mm and for all kinds of vessels. The measuring principle is independent of viscosity, conductivity and chemical properties of the medium. Mounting is carried out on existing pipelines, generally from outside. With small tube diameters, a measuring track is added to the pipeline system. Temperature influences are compensated electronically. Application flow rate measurement The mass flow determination of bulk solids can be simply mounted to existing conveyor belt systems by means of a measurement strap. There is no wear since the measurement is contactlessly and without moving parts. Only narrow space requirements and there are no flow calming sections of the mass flow required. PROTRAC is suitable for various conveyor systems, for example conveyor belt weighers, screw conveyors, chain trough conveyors, steel plate conveyors, bucket conveyors, shafts or tubes with free falling materials AL-EN Radiation-based measurement - Detectors
3 Radiation-based measurement - Detectors Overview FIBERTRAC 31 SOLITRAC 31 Applications: continuous level and interface continuous level and interface measurement measurement Version: flexible plastic detector for round PVT rod detector for cylindrical and conical vessel forms vessel forms Measuring range: mm (individual mm (individual with cascading operation) with cascading operation) Process fitting: from outside on the vessel from outside on the vessel Accuracy: ± 0.5 % ± 0.5 % MINITRAC 31 WEIGHTRAC 31 Applications: density and level detection sensor for mass flow measurement determination Version: NaI detector integrated PVT rod detector for conveyor in the sensor housing belts and screw conveyors Measuring range: mm Process fitting: from outside on the vessel mounting by means of measuring or pipeline frame Accuracy: ± 0.1 % ± 1 % from measuring range final value Radiation-based measurement - Detectors AL-EN - 191
4 FIBERTRAC 31 FIBERTRAC 31 Radiation-based sensor for continuous level measurement Application area FIBERTRAC 31 is a flexible plastic detector for continuous level and interface measurement on round and conical vessels. It is suitable for liquids, buik solids, sludge and suspensions. Advantages Non-contact measurement Ideal for all extreme process conditions Adaptable to all vessel shapes Measuring range up to 7 m Function A slightly radioactive source emits gamma rays which are damped when penetrating vessel wall and medium. The detector on the opposite side of the tank receives the rays, the strength of which is proportional to the level. ø 85,7 mm (3.37") 61,4 mm (2.42") 111,5 mm (4.39") 57 mm (2.24") 235 mm (9.25") 143,6 mm (5.65") 25 mm (1.42") L ø 42 mm (1.58") You will find further process fittings and options under You will find further drawings and charts under You will find mounting accessory and welded sockets in chapter "Information" AL-EN Radiation-based measurement - Detectors
5 FIBERTRAC 31 basic price: Approval XX Without... UG FM(XP-IS)CI.I-III,Div 1GP C-G... KG CSA(XP-IS)CI.I-III,Div 1GP C-G... DK ATEX II 2G Ex d ia IIC T6+1D,2D Ex td IP66 T... DK IEC Zone 1 Ex d ia IIC T6+Ex td A20,A21 IP66 T... Version / Ambient Temperature 1 Standard / -40º...+50ºC... 2 Low temperature range / -50º...+50ºC... Electronics V Four-w ire mA/HART... A Four-w ire ma/hart (Explosion Proof Output)... F Four-w ire Foundation Fieldbus... C Four-w ire Foundation Fieldbus (Ex d output)... P Four-w ire Profibus PA... E Four-w ire Profibus PA (Ex d output)... Housing / Protection D Aluminum / IP66/IP67... W 316L SS / IP66/IP67... Cable Entry / Plug Connection M M20x1.5 / w ithout... N 1/2 NPT / w ithout... Indicating / Adjustment module (PLICSCOM) X Without... B Side mounted w ith backlight... Additional equipment X Without... Active Length A mm... A mm... A mm... A mm... A mm... A mm... A mm... A mm... A mm... A mm... A mm... A mm... A mm... FT31. Radiation-based measurement - Detectors AL-EN - 193
6 SOLITRAC 31 SOLITRAC 31 Radiation-based sensor for continuous level measurement Application area SOLITRAC 31 is a PVT rod detector for continuous level and interface measurement on cylindrical and conical vessels. It is suitable e.g. for reactors, autoclaves, separators and mixers. Advantages Non-contact measurement Ideal for extreme process conditions Simple retrofitting Measurement length up to 3 m Function A slightly radioactive source emits gamma rays which are damped when penetrating the vessel wall and the medium. The PVT detector on the opposite side of the tank receives the rays, the strength of which is proportional to the level. ø 85,7 mm (3.37") 61,4 mm (2.42") 111,5 mm (4.39") 36 mm (1.42") 22 mm (0.87") 235 mm (9.25") 143,6 mm (5.65") ø 76,2 mm (3") L You will find further process fittings and options under You will find further drawings and charts under You will find mounting accessory and welded sockets in chapter "Information" AL-EN Radiation-based measurement - Detectors
7 SOLITRAC 31 basic price: Approval XX Without... UG FM(XP-IS)CI.I-III,Div 1GP C-G... KG CSA(XP-IS)CI.I-III,Div 1GP C-G... DK ATEX II 2G Ex d ia IIC T6+1D,2D Ex td IP66 T... DK IEC Zone 1 Ex d ia IIC T6+Ex td A20,A21 IP66 T... Version / Ambient temperature 1 Standard / -40º...+60ºC... 2 Low temperature range / -50º...+60ºC... Electronics V Four-w ire mA/HART... A Four-w ire ma/hart (Explosion Proof Output)... F Four-w ire Foundation Fieldbus... C Four-w ire Foundation Fieldbus (Ex d output)... P Four-w ire Profibus PA... E Four-w ire Profibus PA (Ex d output)... Housing / Protection D Aluminum / IP66/IP67... W 316L SS / IP66/IP67... Cable entry / Plug connection M M20x1.5 / w ithout... N 1/2 NPT / w ithout... Indicating / Adjustment module (PLICSCOM) X Without... B Side mounted w ith backlight... Additional equipment X Without... Active length A mm... A mm... A mm... A mm... A mm... A mm... ST31. Radiation-based measurement - Detectors AL-EN - 195
8 MINITRAC 31 MINITRAC 31 Radiation-based sensor for level detection and density measurement Application area MINITRAC 31 is an NaI detector for non-contact level detection and density measurement in vessels and on pipelines. Advantages Non-contact measurement Measurement functions reliably under extreme process conditions Simple retrofitting Function A slightly radioactive source emits gammy rays which are damped when penetrating the medium. The MINITRAC detector on the opposite side of the tank receives the rays, the strength of which is proportional to the density of the medium. ø 85,7 mm (3.37") 61,4 mm (2.42") 111,5 mm (4.39") 235 mm (9.25") 143,6 mm (5.65") 57 mm (2.24") You will find further process fittings and options under You will find further drawings and charts under You will find mounting accessory and welded sockets in chapter "Information" AL-EN Radiation-based measurement - Detectors
9 MINITRAC 31 basic price: Approval XX Without... UG FM(XP-IS)CI.I-III,Div 1GP C-G... KG CSA(XP-IS)CI.I-III,Div 1GP C-G... DK ATEX II 2G Ex d ia IIC T6+1D,2D Ex td IP66 T... DK IEC Zone 1 Ex d ia IIC T6+Ex td A20,A21 IP66 T... Version / Ambient Temperature 1 Standard / -40º...+60ºC... 2 Low temperature range / -50º...+60ºC... Ele ctronics V Four-w ire mA/HART... A Four-w ire ma/hart (Explosion Proof Output)... F Four-w ire Foundation Fieldbus... C Four-w ire Foundation Fieldbus (Ex d output)... P Four-w ire Profibus PA... E Four-w ire Profibus PA (Ex d output)... Housing / Protection D Aluminum / IP66/IP67... W 316L SS / IP66/IP67... Cable Entry / Plug Connection M M20x1.5 / w ithout... N 1/2 NPT / w ithout... Indicating / Adjustment module (PLICSCOM) X Without... B Side mounted w ith backlight... Additional equipment X Without... S Int. lead coating to protect against ambient radiation... MT31. Radiation-based measurement - Detectors AL-EN - 197
10 WEIGHTRAC 31 WEIGHTRAC 31 Radiation-based sensor for belt/screw conveyor weigh applications Application area WEIGHTRAC 31 is a mass flow measurement for precise bulk solids detection on conveyor belts and in screw conveyors. PVT is used as scintillation material. Advantages Non-contact measurement Simple mounting through measuring frame Simple retrofitting Function A slightly radioactive source emits gamma rays which are damped when penetrating the medium. The WEIGHTRAC detector on the opposite side of the tank receives the rays, the strength of which is proportional to the density of the medium. From this, the WEIGHTRAC detector calculates the mass. 190 mm (7.5") 175 mm (6.88") 76,2 mm (3") 63,5 mm (2.5") Source holder not included into the scope of delivery! 213 mm (8.38") Y X 152,4 mm (6") You will find further process fittings and options under You will find further drawings and charts under You will find mounting accessory and welded sockets in chapter "Information" AL-EN Radiation-based measurement - Detectors
11 WEIGHTRAC 31 basic price: Approval XX Without... UG FM(XP-IS)CI.I-III,Div 1GP C-G... KG CSA(XP-IS)CI.I-III,Div 1GP C-G... DK ATEX II 2G Ex d ia IIC T6+1D,2D Ex td IP66 T... DK IEC Zone 1 Ex d ia IIC T6+Ex td A20,A21 IP66 T... Version / Ambient Temperature 1 Standard / -40º...+60ºC... 2 Low temperature range / -50º...+60ºC... Ele ctronics V Four-w ire mA/HART... A Four-w ire ma/hart (Explosion Proof Output)... F Four-w ire Foundation Fieldbus... C Four-w ire Foundation Fieldbus (Ex d output)... P Four-w ire Profibus PA... E Four-w ire Profibus PA (Ex d output)... Housing / Protection D Aluminum / IP66/IP67... W 316L SS / IP66/IP67... Cable Entry / Plug Connection M M20x1.5 / w ithout... N 1/2 NPT / w ithout... Indicating/Adjustment module (PLICSCOM) X Without... B Side mounted w ith backlight... Additional equipment X Without... Frame construction A LCS w /Epoxy Pow der Coating... C 316L SS... Conveyor Width / Frame Upright Height N1 500 mm / 300 mm... N2 500 mm / 650 mm... P1 800 mm / 550 mm... P2 800 mm / 950 mm... Q mm / 675 mm... Q mm / 1150 mm... R mm / 900 mm... R mm / 1350 mm... S mm / 1300 mm... S mm / 1750 mm... Source Holder Configuration B Single SHLD - 1 mounting plate... D Dual SHLD - 1 mounting plate... WT31. Radiation-based measurement - Detectors AL-EN - 199
12 Accessory Pipe Mounting Bracket PTB1 Clamping fixture for pipes with mm diameter Application area Clamping fixture for pipes penetrated by radiation at right angles. The source holder and the detector are fix mounted to the tube with a mounting clamp. Advantages Simple mounting through threaded rods Function The clamping fixture is first mounted to the tube, then the source container and the detector. basic price: Pipe Size / Material B1A mm / Low Carbon Steel w /Epoxy pow der coating... B1B mm / 316 Stainless Steel... B2A mm / Low Carbon Steel w /Epoxy pow der coating... B2B mm / 316 Stainless Steel... Mounting Configuration 1 Horizontal detector mounting... 2 Vertical detector mounting (w ith shielding) degree angle mounting... Bracket Configuration X Without... A Vibration isolation (gauge to bracket)... B Thermal isolation (gauge to bracket)... Cooling options X Without... A Prepared for gauge cooling... PTB1. You will find further drawings and charts under AL-EN Radiation-based measurement - Detectors
13 Accessory Pipe Mounting Bracket PTB2 Clamping fixture for pipes with DN DN 900 diameter Application area Clamping fixture for pipes penetrated by radiation at right angles. The source holder and the detector are fix mounted to the tube with a mounting clamp. Advantages Two piece design secures to pipe with bolted connection Function The clamping fixture is first mounted to the tube, then the source container and the detector. basic price: Pipe Size / Material 16A DN400 / Low Carbon Steel w /Epoxy pow der coating... 16B DN400 / 316 Stainless Steel... 20A DN500 / Low Carbon Steel w /Epoxy pow der coating... 20B DN500 / 316 Stainless Steel... 24A DN600 / Low Carbon Steel w /Epoxy pow der coating... 24B DN600 / 316 Stainless Steel... 28A DN700 / Low Carbon Steel w /Epoxy pow der coating... 28B DN700 / 316 Stainless Steel... 32A DN800 / Low Carbon Steel w /Epoxy pow der coating... 32B DN800 / 316 Stainless Steel... 36A DN900 / Low Carbon Steel w /Epoxy pow der coating... 36B DN900 / 316 Stainless Steel... Mounting Configuration 1 Horizontal detector mounting... 2 Vertical detector mounting (w ith shielding)... Bracket Configuration X Without... A Vibration isolation (gauge to bracket)... B Thermal isolation (gauge to bracket)... Offset 1 Standard (centrical)... 2 Offset on the pipe cord (excentric)... Cooling options X Without... A Prepared for gauge cooling... PTB2. You will find further drawings and charts under Radiation-based measurement - Detectors AL-EN - 201
14 Accessory Mounting bracket PTB3 Application area Suitable for wall or tube mounting of PROTRAC instruments Advantages Simple mounting through supplied fixing material Function Mounting bracket for vertical mounting of PROTRAC basic price: Bracket material construction A Low Carbon Steel w /Epoxy pow der coating... C Edelstahl 316L... Bracket Configuration X With threaded studs and hardw are for standard gauge mounting... A Vibration isolation (gauge to bracket)... B Thermal isolation (gauge to bracket)... C With external shielding (vertical MINITRAC 31 only)... PTB3. You will find further drawings and charts under AL-EN Radiation-based measurement - Detectors
Continuous and Point Level Measurement. Radiometric Sensors for Liquid and Solid Level Measurement
Continuous and Point Level Measurement Radiometric Sensors for Liquid and Solid Level Measurement Contents Leadership in Radiometric Technology 3 plics Easy is Better 4 FiberTrac 31 Continuous Level 6
More informationTechnologies, Solutions, and Applications. Radiation-based Level
Technologies, Solutions, and Applications Radiation-based Level Contents Leadership in Radiation-based Level 3 Principle of Operation 4 Models and Versions 6 Radiation-based Level in the plics System 8
More informationTechnology Brochure. Radiation-based process instrumentation
Technology Brochure Radiation-based process instrumentation Contents Non-contact measurement with PROTRAC 3 PROTRAC: Efficient technology and qualified consultation 4 The radiation-based measuring principle
More informationFixed-Point Interface Profiling. Multi-Point Density Array (MDA) Solution for Separation Applications
Fixed-Point Interface Profiling Multi-Point Density Array (MDA) Solution for Separation Applications Contents Leadership in Interface Profiling 3 System and Components Overview 4 Components 6 Principle
More informationSafety instructions VEGADIF DF65.GX*****H/Z/P/F***** IECEx BVS
Safety instructions VEGADIF DF65.GX*****H/Z/P/F***** IECEx BVS 10.0008 Ex td A20, A20/21, A20/22, A21 IP66 T 0044 37675 Contents 1 Area of applicability 3 2 General information 3 2.1 Zone 20 instruments
More informationRonan Model X96S Series Weighing System
Ronan Model X96S Series Weighing System For more than 27 years Ronan has provided the process control industry with unsurpassed products in the harshest environments. With a philosophy of designing new
More informationRonan Model X96S Series Density System
Ronan Model X96S Series Density System For more than 27 years Ronan has provided the process control industry with unsurpassed products in the harshest environments. With a philosophy of designing new
More informationOPTIBAR DP 7060 Supplementary Instructions
OPTIBAR DP 7060 Supplementary Instructions Differential pressure transmitter Category ATEX II 1/2G, 2G Ex db ia IIC T6...T1 Ga/Gb, Gb IECEx Ex db ia IIC T6...T1 Ga/Gb, Gb Housing Aluminium: Single chamber,
More informationContinuous level measurement - Radar transmitters
Overview Configuration Installation Note: Beam angle is the width of the cone where the energy density is half of the peak energy density. The peak energy density is directly in front of and in line with
More informationContinuous level measurement Ultrasonic transmitters
Overview Configuration Parabolic mounting is a 2-wire loop powered ultrasonic transmitter for level, volume and flow monitoring of liquids in open channels, storage vessels, and simple process vessels.
More informationDensity, Concentration and Solids Content. Non-contacting measurement
Density, Concentration and Solids Content Non-contacting measurement S Y S T E M O V E R V I E W Non-contacting measurement technology made by Berthold Berthold density measurement systems are used for
More informationNuclear Density Gauges
Nuclear Density Gauges DensityPRO DensityPRO+ DensityPRO-C ConsistencyPRO CutPRO 3680 Authorised Distributor www.transmin.com.au Thermo Scientific Nuclear Density Gauges Energy Attenuation Gauges The expandable
More informationAdditional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.
Additional Operating Instructions SITRANS F Vortex flowmeters Ex-i Edition 09/2018 CONTENTS 1 Safety instructions 3 1.1 General notes... 3 1.2 EU conformity... 3 1.3 Approval according to the IECEx scheme...
More informationLevel Measurement Continuous level measurement - Ultrasonic transmitters
Overview Configuration Parabolic mounting is a 2-wire loop powered ultrasonic transmitter for level, volume and flow monitoring of liquids in open channels, storage vessels, and simple process vessels.
More informationLevel instruments. Continuous level measurement - Ultrasonic transmitters. SITRANS Probe LU. Overview. Configuration
Overview Configuration is a 2-wire loop powered ultrasonic transmitter for level, volume and flow monitoring of liquids in open channels, storage vessels and simple process vessels. Benefits Continuous
More informationLevel gauges Series LS Level indicator, switch and transmitter for liquids
Level gauges Series LS Level indicator, switch and transmitter for liquids Simple construction Resistant under extreme temperature and pressure conditions No risk of leakage Measuring range: from 150 mm
More informationDräger Polytron 8200 CAT Detection of flammable gases and vapors
Dräger Polytron 8200 CAT Detection of flammable gases and vapors The Dräger Polytron 8200 CAT is an advanced explosion proof transmitter for the detection of flammable gases in the lower explosion limit
More informationAssembly. Host Sub-D Alarm
HighDensity Power Hub, Generic Interface Features Assembly 4 segments, loadsharing redundancy Output: 22... 24 V/360 ma, Ex ib IIC for intrinsically safe, highpower segments Redundant connection to PROFIBUS
More informationUltrasonic Level Measurement nivopuls FDU 10 S
Technical Information TI 275F/00/en Ultrasonic Level Measurement nivopuls FDU 10 S Level limit switch for liquids with separate electronics unit Non-contact from outside Suitable for use in explosion hazardous
More informationDräger Polytron 8700 IR Detection of flammable gases and vapors
Dräger Polytron 8700 IR Detection of flammable gases and vapors The Dräger Polytron 8700 IR is an advanced explosion proof transmitter for the detection of combustible gases in the lower explosion limit
More informationAdditional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA.
Additional Operating Instructions SITRANS F Vortex flowmeters Ex-nA Edition 08/207 CONTENTS Safety instructions 3. General notes... 3.2 EU conformity... 3.3 Approval according to the IECEx scheme... 3.4
More informationModel 144H. Product Data Sheet , Rev DB February Content
Rosemount 144 PC-Programmable Temperature Transmitter Provides an installation-ready solution for temperature monitoring applications using Complete Point Solutions (CPS) Increases measurement accuracy
More informationLevel Measurement Continuous level measurement Ultrasonic transmitters
Overview Configuration is a short-range integrated ultrasonic level transmitter. This intrinsically safe, 2 wire, 4 to 20 ma loop powered transmitter is ideal for liquids, slurries, and bulk materials
More informationTemperature measurement with SITRANS T siemens.com/processinstrumentation
Top values in precision and reliability Temperature measurement with SITRANS T siemens.com/processinstrumentation Temperatures firmly under control Top process quality and efficiency are key factors for
More informationPROFIBUS-PA Display RID 261 PROFIBUS-PA
Technical Information TI 071R/09/en Mat.-Nr.: 510 01194 PROFIBUS-PA Display RID 261 PROFIBUS-PA Display of process values and set point alarms on PROFIBUS-PA systems R Applications Direct connection to
More informationM E A S U R E M E N T S D I V I S I O N
M E A S U R E M E N T S D I V I S I O N ACCURATELY MEASURING WHAT YOU DIDN T THINK WAS MEASURABLE Ronan Engineering, founded in 1959, is a privately held Corporation with the exclusive purpose of manufacturing
More informationAdditional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.
Additional Operating Instructions SITRANS F Vortex flowmeters Ex-d Edition 09/208 CONTENTS Safety instructions 3. General notes... 3.2 EU conformity... 3.3 Approval according to the IECEx scheme... 3.4
More informationDräger Polytron 8310 IR Detection of flammable gases and vapour
Dräger Polytron 8310 IR Detection of flammable gases and vapour The Dräger Polytron 8310 IR is an advanced explosion proof transmitter for the detection of combustible gases in the lower explosion limit
More informationVERSAFLOW VORTEX Supplementary instructions
VERSAFLOW VORTEX Supplementary instructions Vortex flowmeter Equipment category II 2G CONTENTS VERSAFLOW VORTEX 1 Safety instructions 3 1.1 General notes... 3 1.2 EC conformity... 3 1.3 Approval according
More informationCOMPACT FLAME CONTROLLER CFC 1000
COMPACT FLAME CONTROLLER CFC 1000 TECHNICAL DESCRIPTION EDITION: TB CFC1000- REV.6 2012-03-07 Important: Please note, that all mounting and wiring as well as all changing or adjustment at the flame monitoring
More informationTechnologies, Solutions, and Applications. Continuous Level Coke Drum Measurement System
Technologies, Solutions, and Applications Continuous Level Coke Drum Measurement System Leadership in Continuous Coke Drum Level Refiners are processing heavier crude, which increases the amount of resid
More informationPROCESS AUTOMATION PRECISE VALUES LEVEL MEASUREMENT TECHNOLOGY
PROCESS AUTOMATION PRECISE VALUES LEVEL MEASUREMENT TECHNOLOGY POINT LEVEL DETECTION In applications like overfill protection, min/max control, or overflow and dry-run protection, the limit value switches
More informationSitron s CF Line of Flow Switch Monitors
Sitron s CF Line of Flow Switch Monitors Models: CF 12AC CF 12DC CF 420 F 420 RCF 420 Introduction Sitron s versatile and intelligent line of Thermal Dispersion Flow Switch Monitors are compact switches,
More informationSafety instructions VEGABAR 81, 82, 83, 86, 87
C US Safety instructions VEGABAR 81, 82, 83, 86, 87 Dust ignition protection CSA 70015745 Document ID: 52267 Contents 1 Area of applicability... 3 2 General information... 3 3 Technical data... 4 4 Installation
More informationDräger Flame 2500 (IR3) Flame Detection
Dräger Flame 2500 (IR3) Flame Detection With its triple IR sensor The Dräger Flame 2500 detects hydrocarbonbased fires even over greater distances. Moreover, it offers a high reliability against false
More informationRonan Model X90 Series Point Level Monitor
Ronan Model X90 Series Point Level Monitor For more than 27 years Ronan has provided the process control industry with unsurpassed products in the harshest environments. With a philosophy of designing
More informationDSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor
DSF xx15.xx xhv Ex-Atex Product ID Type # Product # Drawing # DSF 1215.01 SHV Ex-atex (5m) 304Z-05197 113216 DSF 1415.01 AHV Ex-atex S148 304Z-05256 113351 DSF 1615.01 SHV Ex-atex (5m) 304Z-05196 113214
More informationCOMPACT FLAME CONTROLLER CFC 200 (Formerly 8.XX)
COMPACT FLAME CONTROLLER CFC 200 (Formerly 8.XX) TECHNICAL DESCRIPTION EDITION: TB CFC200-REV3-2015-04-07 IMPORTANT: Please note, that all mounting and wiring as well as all changing or adjustment at the
More informationCOMPACT FLAME CONTROLLER CFC 2000
COMPACT FLAME CONTROLLER CFC 2000 TECHNICAL DESCRIPTION EDITION: TB_CFC2000_EN_REV09_20150408 Important: Please note, that all mounting and wiring as well as all changing or adjustment at the flame monitoring
More informationTemperature Measurement
/2 Transmitters for mounting in sensor head /6 SITRANS TH100 two-wire system (Pt100) /10 SITRANS TH200 two-wire system universal /17 SITRANS TH00 two-wire system /24 SITRANS TH400 fieldbus transmitter
More informationGTF 103-Ex. GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26. Temperature Probe for potentially explosive atmospheres
Z31.0.XX.6C-11 Temperature Probe for potentially explosive atmospheres (Measuring ranges from -200 to +900 C) Operating Manual GTF 103-Ex 0081 GREISINGER electronic GmbH D - 93128 Regenstauf, Hans-Sachs-Straße
More informationUser s Manual YTA610 and YTA710 NEPSI Certification
User s Manual YTA60 and YTA70 NEPSI Certification [Option code: /NS, /NS5 and /NF] st Edition . INTRODUCTION Thank you for purchasing the YTA60 and YTA70 Temperature transmitters. This manual contains
More informationInstruction Manual September 2010 SITRANS LVL200S
Instruction Manual September 2010 SITRANS LVL200S Contents Contents 1 About this document 1.1 Function.................................. 4 1.2 Target group.............................. 4 1.3 Symbolism
More informationDräger Polytron 8720 IR Detection of carbon dioxide
Dräger Polytron 8720 IR Detection of carbon dioxide The Dräger Polytron 8720 IR is an advanced explosion proof transmitter for the detection of carbon dioxide in percent volume or ppm It uses a high performance
More informationIntroduction to Bulk Solids. The Basics
Introduction to Bulk Solids The Basics Glossary of Terms Angle of Repose This is the angle that material will naturally mound up when filling a tank, or down when discharging a tank. Dielectric Constant
More informationDifferential Pressure and Flow Meter Media 5 Indicator 160 PN 40
Differential Pressure and Flow Meter Media 5 Indicator 160 PN 40 Application Instrument designed to measure and indicate differential pressure or measured variables derived from it For gases or liquids
More informationIntelligent sensing for every temperature and condition
More information: www.siemens.com/sitranst www.siemens.com/processinstrumentation siemens.com/sitranst Siemens Industry, Inc. 3333 Old Milton Parkway Alpharetta, GA 30005 1-800-241-4453 info.us@siemens.com
More informationInstruction Manual September 2010 SITRANS LVL200S
Instruction Manual September 2010 SITRANS LVL200S Contents Contents 1 About this document 1.1 Function.................................. 4 1.2 Target group.............................. 4 1.3 Symbolism
More informationMSM400 Ultrasonic Suspended Solids Monitoring and Control System
Product Data Sheet MSM400 Ultrasonic Suspended Solids Monitoring and Control System Continuous sludge discharge monitor for up to 50% suspended solid The MSM400 system contains a control unit and either
More informationMobrey MSP900SH Level and MSP900FH Flow Ultrasonic Transmitters
Product Data Sheet Non-contacting measurement with no moving parts Fast and simple to install and configure Continuous measurement of level, contents (volume), or open channel flow MCERTS certified version
More informationEnraf Servo Gauge 854 XTG
Enraf Servo Gauge 854 XTG Cut costs, not repeatability. Honeywell s 854 XTG servo gauge is a high performance alternative to other tank level measurement technologies such as radar tank level gauges. It
More informationTemperature Measurement Transmitters for field mounting
Siemens AG 07 Overview Application The SITRANS TF can be used everywhere where temperatures need to be measured under particularly harsh conditions. For that reasons users from all industries have opted
More informationDräger Flame 2500 Flame Detection
Dräger Flame 2500 Flame Detection Working in areas with combustible gases, vapours or materials requires fire/ flame detection as a life-saving necessity. The best solutions must combine state-of-the-art
More informationDräger Polytron 8700 IR Detection of flammable gases and vapors
Dräger Polytron 8700 IR Detection of flammable gases and vapors The Dräger Polytron 8700 IR is an advanced explosion proof transmitter for the detection of combustible gases in the lower explosion limit
More informationRosemount 2051T In-Line Pressure Transmitter
Rosemount 2051T In-Line Pressure Transmitter 2051T In-Line Wireless Pressure Transmitter Configuration Transmitter Output Code 4-20 ma HART 2051 A 2051 with Selectable HART (1) Lower Power 2051 2051 with
More informationDissolved Oxygen Measurement liquisys M COM 223 / 253
Technical Information TI 199C/24/ae Dissolved Oxygen Measurement liquisys M COM 223 / 253 Oxygen Controller Benefits at a glance Liquisys M COM 223 Liquisys M COM 253 Due to the modularity of its design,
More informationEJBX. Ex d. AISI 316L stainless steel. - Zone 1, 2, 21, 22 - Group IIB+H2 - Stainless steel junction boxes - Choice of 13 sizes - IP 66 / 67
Ex d EJBX AISI 316L stainless steel - Zone 1, 2, 21, 22 - Group IIB+H2 - Stainless steel junction boxes - Choice of 13 sizes - IP 66 / 67 Quartz sand blasting Warning labels Mounting bracket Silicone gasket
More informationDSF xx10.xx xhv Ex-Atex Hall Effect Single Channel Speed Sensor
Product ID Type # Product # Drawing # DSF 1210.00 SHV Ex-atex (2m) 374Z-05066 110428F1 DSF 1210.00 SHV Ex-atex (5m) 374Z-05176 110428F1 DSF 1210.00 SHV Ex-atex (10m) 374Z-05590 110428F1 DSF 1410.00 SHV
More informationSnifter ATEX22 VERSION. User Manual. Distributor
Snifter ATEX22 VERSION User Manual Distributor Version 1.4 09/09/2009 Table of Contents 1. INTRODUCTION... 3 1.1. Safety... 3 1.2. Product overview... 4 1.3. How does it work?... 4 2. INSTALLATION... 5
More informationIndustrial Cast-in Circulation Heaters for ATEX/IECEx hazardous areas or in non-atex version
heating for a better future Industrial Cast-in Circulation Heaters for ATEX/IECEx hazardous areas or in non-atex version HEATING GASES HEATING LIQUIDS The CETAL-developed Cast-In Circulation Heater Technology
More information25W Hazardous Location Integrated LED Light Fixture Lumens - Low Profile - ATEX IEC CSA UL
25W Hazardous Location Integrated LED Light Fixture - 3294 Lumens - Low Profile - ATEX IEC CSA UL Part #: HAL-19-25W-ITG-LED Page: 1 The Larson Electronics HAL-19-25W-ITG-LED 25 Watt Explosion Proof Low
More informationLevel instruments. Point level measurement - Capacitance switches. Pointek CLS100 5/9. Overview. Configuration
Level instruments Overview Configuration is a compact 2-wire inverse frequency shift capacitance switch for level detection in constricted spaces, interfaces, solids, liquids, slurries and foam. Benefits
More informationDifferential Pressure and Flow Meter. Media 5 Indicator 160 Ø PN 50
Differential Pressure and Flow Meter Media 5 Indicator 160 Ø PN 50 Application Transmitter for measuring and indicating the differential pressure or measured variables derived from it Suitable for gases
More informationEnraf Servo Gauge 854 ATG
Enraf Servo Gauge 854 ATG Setting the standard in gauging. From the company that pioneered development of modern tank gauges, Honeywell s 854 Automatic Tank Gauge has become an industry standard all over
More informationRosemount 3051CFP Integral Orifice Flowmeter
December 2013 Rosemount 3051 Rosemount 3051CFP Integral Orifice Flowmeter See Specifications on page 47 and options for more details on each configuration. Rosemount 3051CFP Integral Orifice Flowmeters
More informationInstrumentation Products and Applications
1 1/0 Instrumentation Products and Applications 1 Instrumentation Safety barriers I.S. Isolators - DIN rail mounting - Eurocards - Modules Remote I/O Operating and monitoring systems Instrumentation systems
More informationProduct Information to the manual
Product Information to the manual Distributed I/O device ET 200iS, Version 10/2001 Introduction This product information contains fixes and additional information relevant to the user manual Distributed
More informationLaser Level Measurement Products. Introducing the New LLT100
Laser Level Measurement Products BU Measurement and Analytics, June Introducing the New LLT100 Slide 1 Introducing the LLT100 Lasers for level: Now everything is possible The LLT100 revolutionizes the
More informationSITRANS T temperature transmitters A broad product family for every application. sitrans
SITRANS T temperature transmitters A broad product family for every application sitrans The SITRANS T family High-precision, intrinsically safe, and available for a wide variety of sensors Whether you
More informationSafety vacuum drying oven for flammable solvents
VDL series 53 Vacuum drying ovens Safety vacuum drying oven for flammable solvents A BINDER safety vacuum drying oven of the VDL series ensures maximum safety when drying organic solvents standard with
More informationThe sealless FLUX F 424
The sealless FLUX F The liquids to be pumped are abrasive, but they do not leave any deposits. Dry running of the pump must not cause any problems. You are looking for a lightweight, general purpose pump
More informationTechnical Data. Dimensions
0102 Model Number Features Comfort series 50 mm non-flush Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 50 mm Installation non-flush Output polarity NAMUR
More informationCO warning instruments and gas spillage detectors
CO warning instruments and gas spillage detectors For safety & service testo 315-1 testo 315-2 CO testo 317-3 testo 317-1 testo 315-1 Versatile CO measurement For safety and service testo 315-1 CO warning
More informationDräger Flame 2350 (UV&IR) Flame Detection
Dräger Flame 2350 (UV&IR) Flame Detection The Dräger Flame 2350 combines UV and IR sensors for the detection of hydrocarbon-based fires. This combination of sensors offers you more security and fewer false
More informationTemperature Solutions Line Card
Solutions September 2015 We re Your One Stop Temp Shop One simple model number is all it takes to order our complete, Ready-to-Install Assemblies. They include your choice of: Universal PC-Programmable,
More informationMULTI-POINT DENSITY ARRAY FIXED-POINT INTERFACE PROFILING MEASUREMENT
MULTI-POINT DENSITY ARRAY FIXED-POINT INTERFACE PROFILING MEASUREMENT Why Multi-Point DENSITY ARRAY? Leadership in Radiation-Based Measurement Ohmart/VEGA is proud to offer the ultimate in fixed-point
More informationEasy installation Certified for zones 1 and 21 High IP degree of protection
Actuating elements Features Easy installation Certified for zones 1 and 21 High IP degree of protection A large number of variants and versions of actuating elements are available for the ComEx control
More informationWOLF VENTILATION SYSTEM PRICE LIST
VENTILATION SYSTEM PRICE LIST JANUARY 2018 30m 3 /h THE EXTENSIVE EQUIPMENT RANGE from system supplier WOLF offers the ideal solution for commercial and industrial buildings, new build and modernisation
More informationCirculation Heaters Selection Guidelines
Selection Guidelines Selecting a Circulation Heater Application Factors Corrosion Policy Selecting the proper circulation heater component requires critical engineering judgement and careful evaluation
More informationDräger Flame 2100 (UV) Flame Detection
Dräger Flame 2100 (UV) Flame Detection A short response time and high reliability against false alarms are the features of the Dräger Flame 2100. Its UV sensor is quick to detect hydrocarbon- or hydrogen-based
More informationDräger X-am 5600 Personal Monitor Multi-Gas Detection Device
Dräger X-am 5600 Personal Monitor Multi-Gas Detection Device Featuring an ergonomic design and innovative infrared sensor technology, the Dräger X-am 5600 is the smallest gas detection instrument for the
More informationDF1151-Ex Infrared flame detector
DF1151-Ex Infrared flame detector Interactive, for explosion-hazard areas of zones 1 and 2 AlgoRex For inside and outside applications Triple-sensor evaluation Detection in various wavelengths Microprocessor-controlled
More informationAdvanced Diagnostic Gateway with Ethernet and FF-H1 Interface and I/O. Assembly
Advanced Diagnostic Gateway with Ethernet and FF-H1 Interface and I/O Features Assembly System integration kit for Advanced Diagnostics PCS integration via Diagnostic Manager or device DTM Simple automatic
More informationDräger Polytron 5200 CAT Detection of flammable gases and vapours
Dräger Polytron 5200 CAT Detection of flammable gases and vapours The Dräger Polytron 5200 CAT is a cost-effective explosion-proof transmitter for the detection of flammable gases in the lower explosion
More informationLow-Cost, Non-Invasive, Microwave-Based Bulk Solids Flow Detector
Low-Cost, Non-Invasive, Microwave-Based Bulk Solids Flow Detector Granuflow Principle Sensor Features The Granuflow, a non-contact flow sensor, is ideal for monitoring solids flow in pipelines, ducts,
More informationIRtech. E instruments. IRtech Radiamatic IR20 LS series. Infrared Technology
E instruments IRtech Temperature range up to 2200 C Optical resolution up to 300:1 Close focus 0,5mm 8-14µm, 1.6µm, 1µm, 2.3µm, 3.9µm, 4.2µm, 4.6µm, 5.1µm and 7.9µm Spectral response Dual laser true target
More informationIRwin. Methane Leak Detector INNOVATIVE METHANE DETECTOR SYSTEM QUALITY ASSURANCE IN THE AUTOMOTIVE INDUSTRY FOR EASY SURVEY OF GAS PIPELINES
IRwin Methane Leak Detector INNOVATIVE METHANE DETECTOR SYSTEM QUALITY ASSURANCE IN THE AUTOMOTIVE INDUSTRY FOR EASY SURVEY OF GAS PIPELINES Innovation is a matter of difference INNOVATIVE INSTRUMENT AND
More informationDräger Flame 2100 Flame Detection
Dräger Flame 2100 Flame Detection Working in areas with combustible gases, vapors, or materials requires fire/ flame detection as a life-saving necessity. The best solutions must combine state-of-the-art
More informationRTK Instruments Limited St James Business Park, Knaresborough, North Yorkshire, England. HG5 8PJ
Operating Instructions RTK Instruments Limited PEX7250 Explosion Proof Annunciator Introduction This manual provides the information necessary to install, connect, test and maintain the PEX7250 Explosion
More informationLevel Measurement. Point level measurement - Capacitance switches. Pointek CLS100. 5/10 Siemens FI Overview.
Siemens AG 00 Overview Configuration Installation Standpipes 0 () 0 (0.79) max. Wall Restriction is a compact -wire inverse frequency shift capacitance switch for level detection in constricted spaces,
More informationElectronic Pressure Digest. Pressure and Temperature Transmitters
Electronic Pressure Digest Electronic Pressure Digest Pressure and Temperature Transmitters R General Purpose Pressure Transmitters Standard Industrial S-10 These rugged pressure transmitters are designed
More informationIndoor/outdoor resistance thermometer Model TR60
Temperature Indoor/outdoor resistance thermometer Model TR60 WIKA data sheet TE 60.60 for further approvals see page 2 Applications Ambient temperature measurement Air-conditioned rooms, cold-storage rooms,
More informationDräger Flame 2370 (UV&IR) Flame Detection
Dräger Flame 2370 (UV&IR) Flame Detection An extremely short response time and very high reliability against false alarms are the features of the Dräger Flame 2370. It is quick and reliable in detecting
More informationRod probe 11961Z. Technical Information. Conductive level limit detection Partially insulated rod probe for use in conductive liquids
Technical Information Rod probe 11961Z Conductive level limit detection Partially insulated rod probe for use in conductive liquids Application Conductive level limit detection in process or storage tanks
More informationPROCESS AUTOMATION APPLICATION AND SELECTION GUIDELINE FIELDCONNEX FIELDBUS INFRASTRUCTURE
PROCESS AUTOMATION APPLICATION AND SELECTION GUIDELINE FIELDCONNEX FIELDBUS INFRASTRUCTURE Application and Selection Guideline Host Power Supply Junction Boxes FieldBarriers Segment Protectors Terminator
More informationDräger Polytron 7000 Fixed gas detector
DETECTION PERSONAL PROTECTION DIVING TECHNOLOGY SYSTEM TECHNOLOGY SERVICES Dräger Polytron 7000 Fixed gas detector ST-3751-2003 The Dräger Polytron 7000 is a gas detector that can satisfy all toxic and
More informationRosemount 2051T In-line Pressure Transmitter
February 2017 T In-line Pressure Transmitter T In-line Wireless Pressure Transmitter Configuration 4 20 ma HART with Selectable HART (1) Lower Power with Selectable HART (1) FOUNDATION Fieldbus PROFIBUS
More informationSmartLine. RMA803 SmartLine Remote Fieldbus Indicator Specification 34-ST-03-90, December Technical Information.
SmartLine Technical Information RMA803 SmartLine Remote Fieldbus Indicator Specification 34-ST-03-90, December 2015 Introduction The Honeywell RMA803 is a Foundation Fieldbus remote indicator suitable
More informationTechnical Data. General specifications Switching element function Rated operating distance s n 5 mm
0102 Model Number Features 5 mm non-flush Usable up to SIL2 acc. to IEC 61508 Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 5 mm Installation non-flush
More informationRotameter series 250 metal tube variable area flowmeter
Technical data Sheet Flow meter Rotameter series 250 metal tube variable area flowmeter MODELES 250 Stainless Steel indicator 250 PTFE 250 indicator + Alarm 250 electronic transmitter 4-20mA 250 electronic
More information