1 H and GH/G Series UNIT COOERS Technical Bulletin: HGH_00_0 Products that provide lasting solutions.
2 H and GH/G SERIES UNIT COOERS
3 H Series Unit Coolers Dual Discharge ow Hite Series At 9 / maximum height, the H Series is perfect for low clearance walk-in applications in convenience stores, restaurants, food service or wherever more useable storage space is needed in DRY spaces -0 F and up. Standard Features n Compact design with flush ceiling mount takes up less space, allows more product to be stored on the shelf. n EC motors are standard for / and 0/. n Two-way air discharge provides smooth air movement, keeps product fresh longer with less drying and weight loss. n High efficiency coil with staggered copper tubes for optimum heat transfer and proper system balance. n These coils can be used for fluid and CO circuiting. n All controls are factory wired to a terminal strip for easy installation. Optional Features and Accessories n PSC fan motors. n TEV (Thermostatic Expansion Valve) shipped loose or factory mounted. n SV (iquid ine Solenoid Valve) loose. n SHX (Suction iquid Heat Exchanger) loose. Defrost Methods n Air or Off-Cycle for rooms above + F. n Electric for rooms -0 F and above. Specify When Ordering All Models n Complete model number. n Refrigerant R0A, R07, R07A, R07C, R07F, and R8A/R9A. n Room temperature. n Optional features. n Saturated suction temperature. n Optional accessories. Dimensional Data H and GH/G SERIES UNIT COOERS
4 H Series Unit Coolers Model Key H E E A A Unit Type H = ow Hite Number of Fans Fin Spacing FPI FPI Type of Defrost A = Air Defrost B = Brine Air Defrost E = Electric with Electric Pan J = Brine with Electric Defrost Coil and Pan Heater Voltage A = 08-0//0 Motor Voltage A = 08-0//0 B = //0 Motor Type B = PSC Motors (Optional) E = EC Motors (Standard) BTU/h in Hundreds (00) H and GH/G SERIES UNIT COOERS
5 H Series Unit Coolers Defrost Standard Specifications MODE Fins per Inch HA-7 HA-9 HA-0 HA-87 Fins per Inch HA- HA-7 HA-09 HA- CAP. 0 F TD,700 9,00,000 8,700,00 7,00 0,900,00 AIR FOW (CFM) 0,00,90,00 80,70,00,70 CHARGE BS OF REFRIG AIR DEFROST EC MOTORS STANDARD //0 0//0 AMPS WATTS AMPS WATTS PSC MOTORS OPTIONA //0 0//0 AMPS WATTS AMPS WATTS DIMENSIONS (IN) W H SHIPPING WGT. (BS) MODE Fins per Inch HE- HE-8 HE-9 HE-7 Fins per Inch HE- HE-7 HE-00 HE- CAP. 0 F TD SST SST,00 8,00,900 7,00,00,700 0,000,00,700 9,00,000 8,700,00 7,00 0,900,00 AIR FOW (CFM) 0,00,90,00 80,70,00,70 CHARGE BS OF REFRIG EECTRIC DEFROST EC MOTORS STANDARD //0 0//0 AMPS WATTS AMPS WATTS PSC MOTORS OPTIONA //0 0//0 AMPS WATTS AMPS WATTS DIMENSIONS (IN) W H SHIPPING WGT. (BS) EECTRIC DEFROST HEATER DATA OW TEMPERATURE 0//0 MODE Fan 0, 0 AMPS 7. WATTS 00 Fan 08, Fan 9, Fan 7,. 00 Air Defrost Motor Wiring N H F X B Wiring Diagrams Electric Defrost Motor and Defrost Control Wiring S P 7 8 COI HEATERS H and GH/G SERIES UNIT COOERS
6 GH/G Series Unit Coolers Standard Features Ideal for medium temperature low air circulation applications in spaces above +0 F. Standard Features n Ten inch diameter aluminum fans, direct driven at 0 RPM, blow air uniformly through twin coils creating a low velocity umbrella air distribution. n EC motors are standard for / and 0/. n ow and high silhouette models may be installed level and tight to ceiling. Hanger rods and TEV are internal resulting in a clean appearance. n High efficiency coils, four rows deep with /8 diameter staggered copper tubes are mechanically expanded into corrugated aluminum fins spaced by tube collars. Direct expansion circuiting for halocarbon refrigerants is standard. n Serviceable, textured aluminum housing features hinged orifice drain pan, pitched to drain condensate at end of unit. n ow sound levels range from decibels generated by one fan units to 0 decibels for six fan units, as measured on the A scale, six feet horizontally from the center of the unit. n These coils can be used for fluid and CO circuiting. n Capacity ratings are sensible heat removal with externally equalized TEV fed medium frosted coil. Optional Features n Insulated drain pan construction. n Copper fins. n Epoxy coating of entire tube and fin surface. n Coils circuited for water or glycol fluids. n PSC fan motors. Optional Accessories n TEV (Thermostatic Expansion Valve) shipped loose or factory mounted. n SV (iquid ine Solenoid Valve) loose. n SHX (Suction iquid Heat Exchanger) loose or mounted. n Washable Air Inlet Filters (Air Defrost only). Defrost Methods n AIR or OFF-CYCE for rooms above + F. n EECTRIC for rooms +0 F and above (coil only not available with vinyl coated fins or epoxy coated coil) n GAS (KG- pipe) or (HG- pipe) for rooms above + F. n GAS (KGE or HGE) with electric drain pan booster heat for rooms +0 to + F. Specify When Ordering All Models n Complete model number. n Refrigerant. n Room temperature. n Optional features. n Saturated suction temperature. n Optional accessories. H and GH/G SERIES UNIT COOERS
7 GH/G Series Unit Coolers Model Key G D E A K Unit Type GH & G = Gentle Air Number of Fans Fin Spacing FPI FPI Type of Defrost A = Air Defrost B = Brine with Air Defrost C = Brine with Electrical Defrost Coil D = Electric with No Pan Heat F = Pipe Hot Gas with No Pan Heat H = Pipe Hot Gas with Electric Drain Pan M = Pipe Kool Gas with No Pan Heat P = Pipe Kool Gas with Electric Drain Pan Heater Voltage A=08-0//0 B=//0 K=08-0//0 Motor Voltage A=08-0//0 B=//0 Motor Type B=PSC Motors (Optional) E = EC Motors (Standard) BTU/h in Hundreds (00) H and GH/G SERIES UNIT COOERS
8 GH/G Series Unit Coolers Air Defrost Specifications MODE Fins per Inch GHA-0 GHA-0 GHA- GHA-70 GHA-0 GHA-0 Fins per Inch GHA-0 GHA-00 GHA-0 GHA-00 GHA-0 GHA-00 MODE Fins per Inch GA- GA-90 GA- GA-80 GA- GA-8 Fins per Inch GA- GA-70 GA-0 GA-0 GA-7 GA-0 GENTE AIR - 8" HIGH SIHOUETTE - MEDIUM TEMPERATURE PSC MOTORS OPTIONA CAPACITY AIR CHARGE EC MOTORS STANDARD DIMENSIONS (IN) (BTUH) FOW BS OF //0 0//0 //0 0 F TD (CFM) R0A AMPS WATTS AMPS WATTS AMPS WATTS AMPS WATTS W H,000,000 9,800 7,000,000,000,000 0,000,000 0,000,000 0, ,800,700,00,00,00 90,880,80,70,700, GENTE AIR - " OW SIHOUETTE - MEDIUM TEMPERATURE CAPACITY AIR EC MOTORS STANDARD PSC MOTORS OPTIONA CHARGE DIMENSIONS (IN) (BTUH) FOW BS OF //0 0//0 //0 0 F TD (CFM) R0A AMPS WATTS AMPS WATTS AMPS WATTS AMPS WATTS W H,00 9,000,00 8,000,00,800,00 7,000 0,00,000 7,00,000 00,00,800,00,000,00 0,0,890,0,0, SHIPPING WGT. (BS) SHIPPING WGT. (BS) Derate % for PSC motors used for 0 Hertz (BTUH x.088) or increase TD to compensate for lower fan RPM. H and GH/G SERIES UNIT COOERS
9 GH/G Series Unit Coolers Electric Defrost Specifications MODE Fins per Inch GHD-0 GHD-0 GHD- GHD-70 GHD-0 GHD-0 Fins per Inch GHD-0 GHD-00 GHD-0 GHD-00 GHD-0 GHD-00 MODE Fins per Inch GD- GD-90 GD- GD-80 GD- GD-8 Fins per Inch GD- GD-70 GD-0 GD-0 GD-7 GD-0 GENTE AIR - 8" HIGH SIHOUETTE - MEDIUM TEMPERATURE CAPACITY AIR CHARGE EC MOTORS STANDARD PSC MOTORS OPTIONA DIMENSIONS (IN) (BTUH) FOW BS OF //0 0//0 //0 0 F TD (CFM) R0A AMPS WATTS AMPS WATTS AMPS WATTS AMPS WATTS W H,000,000 9,800 7,000,000,000,000 0,000,000 0,000,000 0, ,800,700,00,00,00 90,880,80,70,700, GENTE AIR - " OW SIHOUETTE - MEDIUM TEMPERATURE CAPACITY AIR CHARGE EC MOTORS STANDARD PSC MOTORS OPTIONA DIMENSIONS (IN) (BTUH) FOW BS OF //0 0//0 //0 0 FTD (CFM) R0A AMPS WATTS AMPS WATTS AMPS WATTS AMPS WATTS W H,00 9,000,00 8,000,00,800,00 7,000 0,00,000 7,00,000 00,00,800,00,000,00 0,0,890,0,0, SHIPPING WGT. (BS) SHIPPING WGT. (BS) Derate % for PSC motors used for 0 Hertz (BTUH x.088) or increase TD to compensate for lower fan RPM H and GH/G SERIES UNIT COOERS 7
10 GH/G Series Unit Coolers Electric Defrost Heater Data GH OW TEMPERATURE 0//0 0//0 MODE Fan 00, 00 AMPS 7.0 WATTS 00 AMPS. WATTS 00 Fan 0, Fan, Fan 70, Fan 0, Fan 0, G OW TEMPERATURE 0//0 0//0 MODE Fan 0, 0 AMPS. WATTS 800 AMPS.0 WATTS 800 Fan 090, Fan, Fan 80, Fan, Fan 8, Hot Gas Defrost Drain Pan Heater Data GH OW TEMPERATURE //0 0//0 MODE AMPS WATTS AMPS WATTS Fan 00, Fan 0, Fan, Fan 70, Fan 0, Fan 0, G OW TEMPERATURE //0 0//0 MODE AMPS WATTS AMPS WATTS Fan 0, Fan 090, Fan, Fan 80, Fan, Fan 8, H and GH/G SERIES UNIT COOERS
11 GH/G Series Unit Coolers Dimensional Data UNIT DIMENSIONS SIZE A B C D E F GH- FAN GH- FAN GH- FAN GH- FAN GH- FAN GH- FAN G- FAN G- FAN G- FAN G- FAN G- FAN G- FAN Note: Dimensions in inches. Wiring Diagrams Electric Defrost Motor and Defrost Control Wiring Electric Defrost Heater Wiring N H F X B S P 7 8 G MODE -HEATERS G MODE -HEATERS G MODE -HEATERS GH MODE 8-HEATERS GH MODE 8-HEATERS GH MODE 8-HEATERS Air Defrost Motor Wiring N H F X B S P H and GH/G SERIES UNIT COOERS 9
12 Use your QR reader to reference current document version on Krack, a Hussmann Corporation brand 890 Remington Boulevard Bolingbrook, Illinois 00 Ph: Printed in U.S.A. 0 Krack. a Hussmann Corporation brand HGH_00_0
LH and GH/GL Series UNIT COOLERS. Technical Bulletin. Products that provide lasting solutions.
LH and GH/GL Series UNIT COOLERS Technical Bulletin Products that provide lasting solutions. LH Series Unit Coolers Dual Discharge Low Hite Series At 9 1/" maximum height, the LH Series is perfect for
More informationKR Series COMPACT UNIT COOLERS. Technical Bulletin: KRUC_005_ Products that provide lasting solutions.
KR Series COMPACT UNIT COOERS Technical Bulletin: KRUC_00_07 Products that provide lasting solutions. Provides Excellent Design Innovations That Enhance Overall Refrigeration Performance The KR Compact
More informationMS Series UNIT COOLERS. Technical Bulletin: MSUC_005_ Products that provide lasting solutions.
MS Series UNIT COOLERS Technical Bulletin: MSUC_005_032 Products that provide lasting solutions. Medium Profile Units for Medium Size Walk-In Coolers and Freezers Access Panel Hinged panel cover provides
More informationSM/SV Series PRODUCT COOLERS. Technical Bulletin: SMSV_005_ Products that provide lasting solutions.
SM/SV Series PRODUCT COOLERS Technical Bulletin: SMSV_005_040517 Products that provide lasting solutions. Photo on front cover shown with optional Long Throw Air Boosters Standard Features SM SERIES Ideal
More informationSM/SV Series PRODUCT COOLERS. Technical Bulletin: SMSV_001_ Products that provide lasting solutions.
SM/SV Series PRODUCT COOLERS Technical Bulletin: SMSV_001_083115 Products that provide lasting solutions. Photo on front cover shown with optional Long Throw Air Boosters Standard Features SM SERIES Ideal
More informationSM/SV Series PRODUCT COOLERS. Technical Bulletin. Products that provide lasting solutions.
SM/SV Series PRODUCT COOLERS Technical Bulletin Products that provide lasting solutions. Photo on front cover shown with optional Long Throw Air Boosters Standard Features SM SERIES Ideal for Warehouse
More informationLevitor II. AIR-COOLED CONDENSER WITH ELECTRONICALLY COMMUTATED AXITOP MOTORS (Available for Fluid Cooler Applications)
Levitor II AIR-COOLED CONDENSER WITH ELECTRONICALLY COMMUTATED AXITOP MOTORS (Available for Fluid Cooler Applications) Technical Bulletin: LEVE_002_103116 Products that provide lasting solutions. Table
More informationLow Flow Unit Coolers
BN-LFTB October 2016 Replaces BN-LFTB APR 2015 Low Flow Unit Coolers Technical Guide s LO Air Defrost LOD Electric Defrost LOG Hot Gas Defrost Table of Contents Nomenclature...2 Features & Benefits...3
More informationMicrochannel REMOTE AIR COOLED CONDENSER. Technical Bulletin: MXCC_004_ Products that provide lasting solutions.
Microchannel REMOTE AIR COOLED CONDENSER Technical Bulletin: MXCC_004_030817 Products that provide lasting solutions. Krack s new Microchannel Remote Air Cooled Condenser incorporates a new patented modular
More informationSuper-Flo Low Profile Unit Cooler
Publication No. WT-SAX-0516A Low Profile Unit Cooler Small to Medium Walk-Ins Coolers and Freezer Applications Air Defrost 3,900 to 39,000 BTUH Electric Defrost 3,600 to 28,000 BTUH Hot Gas Defrost 3,600
More informationWIBR SERIES. Unit Coolers - Technical Catalog Hunt St - Pryor, OK Fax
WIBR SERIES Unit Coolers - Technical Catalog 4492 Hunt St - Pryor, OK 74361-918.825.7222 - Fax 800.264.5329 - www.century-refrigeration.com Features/Applications Century Refrigeration s WIBR Series Unit
More informationLOW PROFILE UNIT COOLER
Publication No. RU-AAX-1215A All-Temp 2 B LOW PROFILE UNIT COOLER Air Defrost - 3,900 to 39,000 BTUH Electric Defrost - 3,600 to 28,000 BTUH Hot Gas Defrost - 3,600 to 28,000 BTUH Small to Medium Walk
More informationHigh Profile Evaporator
PRODUCT DATA & INSTALLATION Bulletin K30-KHPA-PDI-5 Part # 1081585 PRODUCT SUPPORT web: k-rp.com/khp email: evaps@k-rp.com call: 1-844-893-3222 x520 scan: High Profile Evaporator High & Medium Temperature
More informationLOW PROFILE UNIT COOLER
Publication No. RU-AAX-0516A All-Temp LOW PROFILE UNIT COOLER Small to Medium Walk-Ins Coolers and Freezer Applications Air Defrost 3,900 to 39,000 BTUH Electric Defrost 3,600 to 28,000 BTUH Hot Gas Defrost
More informationLow Velocity Center Mount Unit Cooler. Technical Guide. Models LWA - Air Defrost LWE - Electric Defrost LWG - Hot Gas Defrost.
LK-LVTB May 2008 Replaces LW-03, February 2003 FPO Low Velocity Center Mount Unit Cooler Technical Guide s LWA - Air Defrost LWE - Electric Defrost LWG - Hot Gas Defrost www.larkinproducts.com Table of
More informationCenter Mount Unit Coolers
CC-CMTB JULY 2017 Replaces CC-CMTB JULY 2016 Center Mount Unit Coolers Technical Guide s TLC Air Defrost TLF Electric Defrost Table of Contents Nomenclature...2 Features & Benefits...3 Performance Data...4
More informationLo-Aire Unit Coolers. Technical Guide. bn-lftb May Models LO Air Defrost LOD Electric Defrost LOG Hot Gas Defrost.
bn-lftb May 2008 Replaces 412.0, May 2004 Lo-Aire Unit Coolers Technical Guide s LO Air Defrost LOD Electric Defrost LOG Hot Gas Defrost www.thecoldstandard.com Table of Contents Nomenclature...2 Features
More informationLow Profile Unit Coolers
BN-LOPTB AUGUST 2018 Replaces BN-LOPTB APRIL 2018 Low Profile Unit Coolers Technical Guide s ADT LET/LLE HGT Table of Contents Nomenclature... 2 Features & Benefits... 3 Performance Data & Specifications...
More informationReach-In Unit Coolers. Technical Guide. Models TA TL C VA BBM BBL KMK RAMK BTO U. LK-RITB June
LK-RITB June 2009 Replaces LK-RITB, January 2004 FPO Reach-In Unit Coolers Technical Guide s TA TL C VA BBM BBL KMK RAMK BTO U www.larkinproducts.com Table of Contents TA Thin Profile Air Defrost... 3
More informationMicrochannel REMOTE AIR COOLED CONDENSER WITH ELECTRONICALLY COMMUTATED AXITOP MOTORS. Technical Bulletin. Products that provide lasting solutions.
Microchannel REMOTE AIR COOLED CONDENSER WITH ELECTRONICALLY COMMUTATED AXITOP MOTORS Technical Bulletin Products that provide lasting solutions. Krack Corporation has a long tradition of leadership and
More informationA Series T 3. Unit Coolers - Technical Catalog. Product Benefits: Comdustrial TM Refrigeration. Adaptability- Durability- Serviceability-
A Series Unit Coolers - Technical Catalog Product Benefits: T 3 $ Adaptability- Century systems go where others can t. Your Century system is engineered to meet your specific project application and job
More informationLOW PROFILE UNIT COOLER. Technical Guide. Models RLC Air Defrost ELC/EFC Electric Defrost GLC Hot Gas Defrost. CH-LOPTB May,
CH-LOPTB May, 2008 Replaces CH-B-15B, March 2004y 2007 LOW PROFILE UNIT COOLER Technical Guide s RLC Air Defrost ELC/EFC Electric Defrost GLC Hot Gas Defrost www.chandlerref.com Table of Contents Nomenclature...2
More informationLow Profile Unit Coolers
CH-LOPTB MAR 2015 Replaces CH-LOPTB JAN 2015 Low Profile Unit Coolers Technical Guide s RLC Air Defrost ELC/EFC Electric Defrost GLC Hot Gas Defrost Table of Contents Nomenclature 2 Features & Benefits
More informationPRODUCT. TWB Two-Way Air Defrost Unit Coolers PRODUCT DATA & INSTALLATION. High Temperature (35 o F / 1.7 o C or Higher) Applications
DATA & INSTALLATION Bulletin RPDI0 04385 KEEPRITE TWOWAY UNIT COOLER UNIT SERIES B = ND GENERATION BTUH CAPACITY @ o F TD (0Hz) e.g. 450 = 4500 @ 0 o F TD TYPE OF DEFROST A = AIR DEFROST (HIGH TEMP) ELECTRICAL
More informationKTL Two-Way Low Profile Evaporators
PRODUCT DATA & INSTALLATION Bulletin K30--PDI-16 Part # 87830 PRODUCT SUPPORT web: k-rp.com/ktl email: evaps@k-rp.com call: 1-844-893-3222 x520 scan: Two-Way Low Profile Evaporators High, Medium and Low
More informationKR Electrical Defrost Unit Coolers (PN E108318_E)
KR Series Electric Defrost Unit Coolers Operating and Installation Manual KR Electrical Defrost Unit Coolers (PN E108318_E) TABLE OF CONTENTS 1 LOCATION RECOMMENDATIONS... 2 2 UNIT MOUNTING... 2 3 DRAIN
More informationLow Profile Unit Cooler. ECM Motors. All-Temp²B. Small to Medium Walk - Ins. Coolers & Freezer Applications. Now available with optional
Now available with optional ECM Motors High Efficiency / High Reliability Low rofile Unit Cooler ublication No. 100.14 January, 2008 MEA Air Defrost - 3,900 to 39,000 BTUH Electric Defrost - 3,600 to 28,000
More informationSM/SV-Space Master Unit Coolers (E R.0)
SM/SV Series Space Master Unit Coolers Operating and Installation Manual SM/SV-Space Master Unit Coolers (E316008 R.0) TABLE OF CONTENTS 1 RECEIPT OF EQUIPMENT 3 1.1 INSPECTION 3 1.2 LOSS OF GAS HOLDING
More informationInstallation, Operation, and Maintenance Information
Installation, Operation, and Maintenance Information Low Velocity Unit Coolers Bulletin No. IOM 110.3 Table of Contents Inspection... 2 Installation... 2 4 General... 2 Location... 2 Drain Line... 3 Refrigerant
More informationReach-In Unit Coolers: ASL 2 Slim-Temp 2 Wedge-Temp 3 Flex-Temp 3 Mullion-Temp 3 T-Temp 4 Twin-Temp 4 Mini-Twin-Temp 4 Wall-Temp 5
` RLP 2-2017 Supersedes RLP 8-2016 and all previous versions LIST PRICES February, 2017 All products, except surface coils and parts, are shipped F.O.B. point of shipment with full freight allowed on single
More informationUnit Coolers Evaporator & Condenser Coils Aluminum Extrusion Heat Transfer Products
PRUCT CATALOG Unit Coolers Evaporator & Condenser Coils Aluminum Extrusion Heat Transfer Products peerlessofamerica.com Welcome to Peerless of America II Peerless of America II Inc. was founded in 1912
More informationcommercial refrigeration products
commercial refrigeration products Evaporators Condensing Units Condensers Air Handlers Fluid Coolers Coils NOTHING BEATS A BALLY Evaporators EC MOTORS Available Half Round Low velocity Two-way low profile
More informationReach-In Unit Coolers: ASL 2 Slim-Temp 2 Wedge-Temp 3 Flex-Temp 3 Mullion-Temp 3 T-Temp 4 Twin-Temp 4 Mini-Twin-Temp 4 Wall-Temp 5
` RLP 1-2019C Prices effective January 1, 2019. Supersedes all earlier versions LIST PRICES All products, except surface coils and parts, are shipped F.O.B. point of shipment with full freight allowed
More informationPage ` RLP R1. Supersedes all earlier versions LIST PRICES April, 2018
` RLP 4-2018 R1 Supersedes all earlier versions LIST PRICES April, 2018 All products, except surface coils and parts, are shipped F.O.B. point of shipment with full freight allowed on single orders with
More informationPage ` RLP A. Supersedes all earlier versions LIST PRICES Prices effective 7/2/18
` RLP 7-2018A Supersedes all earlier versions LIST PRICES Prices effective 7/2/18 All products, except surface coils and parts, are shipped F.O.B. point of shipment with full freight allowed on single
More informationLK-PL Jan Price List
LK-PL Jan. 2018 Price List Introduction Featured Products... Quick Section Listing Unit Coolers 1 Reach-In Unit Coolers Slim Contour Unit Cooler See page 14 11 Step-In Unit Coolers Low Profile Unit Cooler
More informationBTL Two-Way Low Profile Evaporators
PRODUCT DATA & INSTALLATION Bulletin B30-BTL-PDI-3 1087832 Latest product updates and further information at w ww.ballyrefboxes.com BTL Two-Way Low Profile Evaporators High, Medium and Low Temperature
More informationCompak Unit Coolers. LCA - Air Defrost LCE - Electric Defrost LCH - Hot Gas Defrost. Bulletin LC-03A August 2004 (Replaces LC-03 3/03)
Bulletin LC-03A August 2004 (Replaces LC-03 3/03) Compak Unit Coolers LCA - Air Defrost LCE - Electric Defrost LCH - Hot Gas Defrost 3,500 to 27,000 BTU/H Front access to refrigeration components. Now
More informationPrice List. BN-PL Oct. 2017
Price BN-PL Oct. 2017 Introduction Featured Products... Quick Section ing Unit Coolers 1 Reach-In Unit Coolers Slim Contour Unit Cooler See page 14 11 Step-In Unit Coolers Low Profile Unit Cooler See page
More informationRLP Page. Prices effective January 1, Supersedes all earlier versions LIST PRICES
` RLP 1-2019 Prices effective January 1, 2019. Supersedes all earlier versions LIST PRICES All products, except surface coils and parts, are shipped F.O.B. point of shipment with full freight allowed on
More informationPrice List. BN-PL Jan. 2018
BN-PL Jan. 2018 Introduction Featured Products... Quick Section ing Unit Coolers 1 Reach-In Unit Coolers Slim Contour Unit Cooler See page 14 11 Step-In Unit Coolers Low Profile Unit Cooler See page 18
More informationSlim Contour Unit Cooler
Slim Contour Unit Cooler with Modular Cassette Design ULA/ULE Models LK-SLIM-TB l APRIL 2018 Replaces LK-SLIM-TB l SEPT 2016 ULA/ULE - Slim Contour Unit Cooler Maximized Storage, Minimized Energy The Slim
More informationLOW PROFILE EVAPORATORS
PS SERIES & PSL SERIES LOW PROFILE EVAPORATORS MEDIUM & LOW TEMPERATURE EVAPORATORS ORIGINAL MANUFACTURED EQUIPMENT PS Series PSL Series HX-404-3 AUS Product Specifications The PS Series Low Line Evaporators
More informationSM/SV Series Space Master Unit Coolers Operating and Installation Manual
SM/SV Series Space Master Unit Coolers Operating and Installation Manual SM/SV-Space Master Unit Coolers (E316008_G) TABLE OF CONTENTS 1 RECEIPT OF EQUIPMENT 3 1.1 INSPECTION 3 1.2 LOSS OF GAS HOLDING
More informationNH 3. Dual Discharge Evaporator. Ammonia Industrial Applications 1-16 Tons MDAN
NH 3 Dual Discharge Evaporator Ammonia Industrial Applications 1-16 Tons MDAN > > U s e d f o r S m a l l t o m e d i u m I n d u s t r i a l A m m o n i a a p p l i c a t i o n s Manufactured with Stainless
More informationPrice List. CC-PC-PL Jan. 2019
Price List CC-PC-PL Jan. 2019 Introduction Featured Products... Quick Section Listing Unit Coolers 1 Reach-In Unit Coolers Slim Contour Unit Cooler See page 14 Low Profile Unit Cooler See page 18 11 14
More informationKR Series Air Defrost Unit Coolers Operating and Installation Manual
KR Series Air Defrost Unit Coolers Operating and Installation Manual KR Air Defrost Unit Coolers (PN E108317_L) TABLE OF CONTENTS 1 RECEIPT OF EQUIPMENT... 2 1.1 INSPECTION... 2 1.2 LOSS OF GAS HOLDING
More informationKTL Two-Way Low Profile Unit Coolers
PRODUCT DATA & INSTALLATION Bulletin K30-KTL-PDI-2 1087830 KTL Two-Way Low Profile Unit Coolers High, Medium and Low Temperature Applications -10 F (-23.3 C) and above Air or Electric Defrost Electrical
More informationMHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH
MHNCCW-04-01 (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH Rev. 1.2 HVAC Guide Specifications Chilled and Hot Water Fan Coil 4-Pipe Nominal Size: 12,000
More informationTLV Low Velocity Evaporators
PRODUCT DATA & INSTALLATION Bulletin T30-TLV-PDI-27 Part # 1073478 PRODUCT SUPPORT web: t-rp.com/tlv email: evaps@t-rp.com call: 1-844-893-3222 x520 scan: TLV Low Velocity Evaporators High Temperature
More informationMHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH
MHCCW-10-05 Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH Rev. 1.21 HVAC Guide Specifications Chilled Water Fan Coil with Electric Heat 2-Pipe Nominal Size:
More informationMHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH
MHCCW-06-00 Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH Rev. 1.21 HVAC Guide Specifications Chilled or Hot Water Fan Coil 2-Pipe Nominal Size: 18,000 BTUH
More informationCFFWA4P-16-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 48,000 BTUH
CFFWA4P-16-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 48,000 BTUH Rev. 1.3 HVAC Guide Specifications Chilled and Hot Water Universal Mount Fan Coil 4-Pipe Nominal
More informationCFFWA4P-12-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 36,000 BTUH
CFFWA4P-12-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 36,000 BTUH Rev. 1.3 HVAC Guide Specifications Chilled and Hot Water Universal Mount Fan Coil 4-Pipe Nominal
More informationMulti-position, Upflow, Horizontal Left, or Horizontal Right, Modular Air Handlers
Multi-position, Upflow, Horizontal Left, or Horizontal Right, Modular Air Handlers 60 HZ Convertible Air Handlers Model: Series 2 Air Handlers 1.5-3 ton Standard Coil Black Epoxy Coil GAF2A0A18S11SE GAF2A0A18S11EE
More informationCFFWA4P-08-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 24,000 BTUH
CFFWA4P-08-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 24,000 BTUH Rev. 1.3 HVAC Guide Specifications Chilled and Hot Water Universal Mount Fan Coil 4-Pipe Nominal
More informationSTC Series Twin Unit Coolers (E329630_A)
STC Series Twin Unit Coolers Operating and Installation Manual STC Series Twin Unit Coolers (E329630_A) TABLE OF CONTENTS 1 RECEIPT OF EQUIPMENT 3 1.1 INSPECTION 3 1.2 LOSS OF GAS HOLDING CHARGE 3 2 ASSEMBLY
More informationBlow through unit coolers LEX. Standard coolers for cooling & freezing rooms
Blow through unit coolers LEX Standard coolers for cooling & freezing rooms O `çåíéåíë pag. Model indication..................................2 Eurovent.......................................2 General
More informationIndustrial Unit Coolers
HC.CH-IUC l March 2016 Industrial Unit Coolers Sales Brochure We Know Cold Storage Heatcraft Worldwide Refrigeration announces its latest addition of large capacity unit coolers for the Cold Storage and
More informationMHCFC4W Chilled/Hot Water Cassette Fan Coil
MHCFC4W-16-01 Chilled/Hot Water Cassette Fan Coil 4-Pipe Heat / Cool Fan Coil 48,000 BTUH Rev. 1.1 HVAC Guide Specifications Chilled and Hot Water Cassette Fan Coil 4-Pipe Nominal Size: 48,000 BTUH Multiaqua
More informationMHCFC4W Chilled/Hot Water Cassette Fan Coil
MHCFC4W-04-01 Chilled/Hot Water Cassette Fan Coil 4-Pipe Heat / Cool Fan Coil 12,000 BTUH Rev. 1.2 HVAC Guide Specifications Chilled and Hot Water Cassette Fan Coil 4-Pipe Nominal Size: 12,000 BTUH Multiaqua
More informationMHCFC4W Chilled/Hot Water Cassette Fan Coil
MHCFC4W-08-01 Chilled/Hot Water Cassette Fan Coil 4-Pipe Heat / Cool Fan Coil 24,000 BTUH Rev. 1.1 HVAC Guide Specifications Chilled and Hot Water Cassette Fan Coil 4-Pipe Nominal Size: 24,000 BTUH Multiaqua
More informationRheem Air Handler. RF1T- Series X-13 (ECM) Motor Efficiencies up to 16 SEER. RF1P- Series PSC Motor Efficiencies up to 14.5 SEER
Air Handlers Rheem Air Handler RF1T- Series X-13 (ECM) Motor Efficiencies up to 16 SEER RF1P- Series PSC Motor Efficiencies up to 14.5 SEER Front or Bottom Return with aluminum tube and fin coil Flow Check
More informationEvaporator E4 Series. Innovative Refrigeration Solutions. Floor Mounted Blast Chiller/Freezer F - Series
Evaporator E4 Series Floor Mounted Blast Chiller/Freezer F - Series Ceiling Mounted Blast Chiller/Freezer C - Series Medium & Low Temperature Models Application Benefits / Features NOMENCLATURE GREENHALGH
More informationHEATING & COOLING COIL PRODUCTS
HEATING & COOLING COIL PRODUCTS FV & FVH FLOOR MOUNTED COOLERS Capacities 28-150kW White powder coated casing Aerofoil fans 4, 6 or 8mm fin spacing Vertical or horizontal air discharge HEATING & COOLING
More informationMH1WC4W-06-1-B Chilled/Hot Water 1-Way Cassette Fan Coil
MH1WC4W-06-1-B Chilled/Hot Water 1-Way Cassette Fan Coil 4-Pipe Heat / Cool Fan Coil 18,000 BTUH Rev. 1.11 HVAC Guide Specifications Chilled and Hot Water Cassette Fan Coil 4-Pipe Nominal Size: 18,000
More informationHigh Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)
High Ambient / High Efficiency Series R - 410a 50Hz Ducted Split Air Conditioners (5.0 kw - 17.5 kw) ISO 9001 : 2008 ISO 14001 : 2004 ISO 18001 : 2007 R - 410a 50Hz Introduction: Established in the year
More informationRuud Air Handler. RF1T- Series X-13 (ECM) Motor Efficiencies up to 16 SEER. RF1P- Series PSC Motor Efficiencies up to 14.5 SEER
Air Handlers Ruud Air Handler RF1T- Series X-13 (ECM) Motor Efficiencies up to 16 SEER RF1P- Series PSC Motor Efficiencies up to 14.5 SEER Front or Bottom Return with aluminum tube and fin coil Flow Check
More informationMHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH
MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH 318 MHNCCX NOMENCLATURE BREAKDOWN 4-Pipe Heat/Cool Ceiling Concealed Fan Coil MHNCCW- XX - XX Ceiling Concealed
More informationSPECIFICATIONS FOR WALK-IN COOLERS & FREEZERS
SPECIFICATIONS FOR WALK-IN COOLERS & FREEZERS GENERAL Standard walk-in panels to be constructed of 4, 5", 6",8",10" or 12 thick prefabricated panels. PANEL CONSTRUCTION Panels consist of die-formed interior
More informationSPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU090, K3EU120 & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION ACCESSORIES FIELD INSTALLED
(491) SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU, K3EU & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION These completely assembled units include a well-insulated cabinet, a DX cooling coil with copper tubes
More informationCatalog C: McQuay Horizontal Concealed Fan Coil Unit
Catalog C: 700-1 McQuay Horizontal Concealed Fan Coil Unit Model THC Sizes 200 Through 1200 CFM McQuay THC Horizontal Concealed Fan Coil Nomenclature F THC 1 H02 Fan-coil Type of Unit THC = Horizontal
More information30GT FLOTRONIC AIR-COOLED CHILLERS
30GT-41SB 30GT040-110 FLOTRONIC AIR-COOLED CHILLERS PERFORMANCE DATA FIELD WIRING DIAGRAM 1998 Carrier Corporation Syracuse, New York 13221 Form 30GT-41SB Supersedes 30GT-21SB, 30GT-22SB, 30GT-23SB, Printed
More informationThe ideal cooler at a competitive price KELVION TEC COMMERCIAL AIR COOLER
The ideal cooler at a competitive price KELVION TEC COMMERCIAL AIR COOLER Kelvion a tribute to Lord Kelvin Lord Kelvin (1824 1907) formulated the laws of thermodynamics 70 branches and sales partners
More informationEvaporator Coils. Back Mount Coils ( Back Bar ) Top Mount Thin Profile Coils. High Performance Mullion Coils
Evaporator Coils Back Mount Coils ( Back Bar ) Top Mount Thin Profile Coils High Performance Mullion Coils The AMCO High Performance Coils AMCO high performance direct expansion evaporator coils are designed
More informationRefrigeration Systems by. Cool You Can Count On!
Refrigeration Systems by Cool You Can Count On! www.ref-sys.com Keeping Storage Cool... Refrigeration Systems (RSI) has provided engineered cooling systems to agricultural refrigeration markets and vegetable
More informationTECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)
DESCRIPTION These units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging. Each unit is pressurized with a holding charge of refrigerant-22 for storage
More informationAir-Cooled Condensing Units with Compact Screw Compressors
LK-SCUTB March 2015 Air-Cooled Condensing Units with Compact Screw s Technical Bulletin Models SSV DSV Table of Contents Nomenclature Chart... 2 Introduction... 3 Bitzer TM s... 4 Magnum TM Microprocessor...
More informationMACH N-407 Heat Pump Air-Cooled Chiller
MACH060-01-N-407 Heat Pump Air-Cooled Chiller Heat Pump Air-Cooled Chillers for Global Residential and Light Commercial Microclimates MACH NOMENCLATURE BREAKDOWN MACH-060-01 - N - 407 Refrigerant Type
More informationTEC Coolers. GEA Heat Exchangers. GEA Searle
TEC Coolers GEA Heat Exchangers GEA Searle Quality and Performance making the difference Quality and Performance Eurovent Certification All applicable products are certified under the Eurovent CERTIFYALLprogram,
More informationFALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)
FALCON Rooftop Units ACPSE 50/60Hz Cooling : 36 to 1388 MBH (11 to 407 ) Heating : 40 to 1298 MBH (12 to 380 ) R Products that perform...by people who care NOMENCLATURE 6 AC P S E 435 P - HP G Q 6-60 Hz
More informationCB18/CBS18 Bulletin # September 1994 Supersedes August 1986
ENGINEERING DATA CB18 SERIES UP-FLOW CBS18 SERIES HORIZONTAL 2 To 5 Ton (7 To 18 kw) Nominal Cooling Capacity 7200 To 102 400 Btuh (2.1 To 30.0 kw) Optional Electrical Heat ENGINEERING DATA COILS MATCHED
More information1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series
1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series Rated in accordance with ARI Standard 210. Certification applies only when used with proper components as listed with ARI. FEATURES Designed as an upflow indoor
More information30GN FLOTRONIC II AIR-COOLED CHILLERS
30GN-19SB 30GN040-110 FLOTRONIC II AIR-COOLED CHILLERS PERFORMANCE DATA FIELD WIRING DIAGRAM 1998 Carrier Corporation Syracuse, New York 13221 Form 30GN-19SB Supersedes 30GN-6SB, 30GN-7SB, 30GN-8SB, Printed
More informationPACKAGE AIR CONDITIONER
PACKAGE AIR CONDITIONER FORM NO. ATZ-206 TZAA- HIGH EFFICIENCY SERIES NOMINAL SIZE 10 TON [35.2 kw] 10 TON MODEL [35.2 kw] This product is shipped with a nitrogen holding charge that must be vented prior
More informationProduct Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons
Product Data 50HS Single-Package Heat Pumps 1 1 2 to 5 Nominal Tons Single-Package Heat Pump for Manufactured Housing/Residential and Light Commercial use. Features/Benefits One-piece heat pumps with optional
More informationSeasonMaker ThinLine Fan-coil Units
Catalog C: 720-12 SeasonMaker ThinLine Fan-coil Units Type TSH & TSC Horizontal Design TSS, TPF, TSF & TSB Vertical Design C L I S T E D Ratings Certified by the Air Conditioning & Refrigeration Institute
More informationSECTION 5 COMMERCIAL REFRIGERATION UNIT 21 EVAPORATORS AND THE REFRIGERATION SYSTEM UNIT OBJECTIVES 3/22/2012 REFRIGERATION
SECTION 5 COMMERCIAL REFRIGERATION UNIT 21 EVAPORATORS AND THE REFRIGERATION SYSTEM UNIT OBJECTIVES After studying this unit, the reader should be able to Define high-, medium-, and low-temperature refrigeration.
More informationMAC-120HE-03 Air-Cooled Chiller
MAC-120HE-03 Air-Cooled Chiller 10 Ton / 120,000 BTUH Air-Cooled Chiller 380/415/460-3-50/60 1 HVAC Guide Specifications Air-Cooled Liquid Chiller Nominal Size: 10 Tons Multiaqua Model Number: MAC-120HE-03
More informationUnit Data - RCA 051 RATED IN ACCORDANCE TO AHRI STANDARD
RATED IN ACCORDANCE TO AHRI STANDARD 365-2009 1 Data - RCA 051 RATED IN ACCORDANCE TO AHRI STANDARD 365-2009. Performance Data Electrical Data Mechanical Data Net Cooling Compressor(s) Condenser Fan Motor(s)
More informationRheem Air Handler. RHBL- Series X-13 (ECM) Motor Efficiencies up to 16 SEER. RHAL- Series PSC Motor Efficiencies up to 14.5 SEER
Air Handlers Rheem Air Handler RHBL- Series X-13 (ECM) Motor Efficiencies up to 16 SEER RHAL- Series PSC Motor Efficiencies up to 14. SEER Front or Bottom Return Flow Check Piston for cooling or heat pump
More informationKAP Horizontal Product Coolers
PRODUCT DATA & INSTALLATION Bulletin K80-KAP-PDI-6 Part # 1097718 PRODUCT SUPPORT web: k-rp.com/kap email: ahu@k-rp.com call: 1-844-893-3222 x527 scan: KAP Horizontal Product Coolers Air Defrost for Applications
More informationModular Multi-position Air Handlers
Modular Multi-position Air Handlers Black Epoxy Coil TAM4A0A18S11ED TAM4A0A24S21ED TAM4A0A30S21ED TAM4A0A36S31ED TAM4A0B42S31ED TAM4A0C48S41ED TAM4A0C60S51ED Standard Coil TAM4A0A18S11SD TAM4A0A24S21SD
More informationProduct Data. Features/Benefits. 50HS Single-Package Heat Pump Units 50 Hz
Product Data 50HS Single-Package Heat Pump Units 50 Hz Nominal: 7 to 18 kw (2 to 5 Tons) Single-Package Heat Pump for Manufactured Housing/Residential and Light Commercial use. Features/Benefits One-piece
More informationAIR HANDLERS AIR HANDLERS
FORM NO. H11-33 REV. 1 Supersedes Form No. H11-33 AIR HANDLERS AIR HANDLERS RHBL- Efficiency X-13 (ECM) featuring Industry Standard R-410A Refrigerant RHAL- Standard Efficiency PSC featuring Industry Standard
More informationCompact CUBIC. Air cooler GSF. Highly efficient compact air cooler Optimal for commercial refrigeration. HFCs 1 55 kw
INFO CUBIC Compact Air cooler GSF Highly efficient compact air cooler Optimal for commercial refrigeration HFCs 1 55 kw Everything an air cooler requires The universal solution for commercial refrigeration!
More informationHIGH EFFICIENCY AIR HANDLER
FORM NO. HFJ- Supersedes Form No. PTZ-789 HIGH EFFICIENCY AIR HANDLER Features FH***TTS feature a Constant Torque motor (ECM) which provides enhanced SEER performance with most Rheem outdoor units. Versatile
More informationINSTALLATION and OPERATION INSTRUCTIONS
INSTALLATION and OPERATION INSTRUCTIONS Utility Coolers MODEL NOS. US4KP US10KP IMPORTANT INFORMATION This manual has been prepared to assist you in the installation of your Utility Cooler and to acquaint
More informationReport No CRT-414
Unit Nameplate Manufacturer: Available upon request form XDX Model No.YSC120E3RHAOWJX Serial No. 807103096L Volts: 208/230 Hertz: 60 Phase: 3 Refrigerant Type: R-410A Indoor Fan Motor Manufacturer: G.
More informationLIST PRICES SEE THE BACK COVER FOR "CONDITIONS OF SALE AND WARRANTY"
BULLETIN KLP 4-2018 R1 Supersedes All KRAMER Price Lists Published Prior To April 2018 April, 2018 LIST PRICES Add appropriate expansion valve price(s) from page 13 of this price sheet when unit coolers
More information