1 Technical Support Division
2 New CMV System - Floor ceiling Indoor Unit 1 1. External appearance 2. Nomenclature 3. Specifications 4. Dimensions 5. Service space 6. Piping diagram 7. Wiring diagram 8. Capacity tables 9. Electric characteristics 10. Sound pressure levels 11. Accessories 12. Exploded view
3 2 1. External appearance New CMV System - Floor ceiling Indoor Unit 2. Nomenclature CMV - D 160 LD / H N R1 - B Design code B: 2nd generation Refrigerant type R1: R410A Power code N: 208~230V/1PH/60Hz Omit: 220~240V/1PH/50Hz Function code H: Heat pump Indoor unit code Q: 4-way cassette G: Wall-mounted TA: Low ESP ducted TB: Medium ESP ducted TH: High ESP ducted LD: Floor ceiling TF: Full fresh air processor Capacity (*100W) DC Fan motor Chigo VRF system
4 New CMV System - Floor ceiling Indoor Unit 3. Specifications 3 Model CMV-D45LD/HR1-B CMV-D56LD/HR1-B CMV-D71LD/HR1-B Power supply V/1PH/50Hz V/1PH/50Hz V/1PH/50Hz Capacity Cooling kw Heating kw Power Input kw Model DR LD-8 DR LD-8 DR LD-8 Fan motor Type DC DC DC Brand Panasonic Panasonic Panasonic Indoor coil Speed (Hi/Med/Low) r/min 800/650/ /650/ /880/780 Number of rows Fin type Hydrophilic aluminum Hydrophilic aluminum Hydrophilic aluminum Tube diameter and type mm Ø9.53,Innergroove tube Ø9.52,Innergroove tube Ø9.52,Innergroove tube Air flow (High speed) m 3 /h Sound power level db(a) 37~46 37~46 39~48 Body Dimension (W H D) mm Packing (W H D) mm Net/Gross weight kg 36/42 36/42 36/42 Refrigerant type R410A R410A R410A Throttle type EXV EXV EXV Design pressure MPa Liquid pipe / Gas pipe mm Ø6.35/ Ø12.7 Ø6.35/ Ø12.7 Ø9.53/ Ø15.88 Connecting wire Power wire mm 2 2.5*3 2.5*3 2.5*3 Signal wire mm *2 0.75*2 0.75*2 Drainage water pipe (Outer diameter) mm Ø20 Ø20 Ø25 Controller Standard Remote controller Remote controller Remote controller Optional Wired controller Wired controller Wired controller Operation temp C 16~32 16~32 16~32 Notes: 1) Nominal cooling capacities are based on the following conditions. Outdoor temperature: 35 C DB Return air temperature: 27 C DB, 19 C WB Equivalent piping length: 8m in horizontal 2) Nominal heating capacities are based on the following condition. Outdoor temperature: 7 C DB, 6 C WB Return air temperature: 20 C DB Equivalent piping length: 8m in horizontal 3) Sound pressure level: Semi-anechoic chamber conversion value, measured at a point 1 m in front of the unit at a height of 1.4 m. 4) The above data may be changed without notice for future improvement on quality and performance.
5 4 New CMV System - Floor ceiling Indoor Unit Model CMV-D80LD/HR1-B CMV-D90LD/HR1-B CMV-D112LD/HR1-B Power supply V/1PH/50Hz V/1PH/50Hz V/1PH/50Hz Capacity Cooling kw Heating kw Power Input kw Model DR LD-8 DR LD-8 2*DR LD-8 Fan motor Type DC DC DC Brand Panasonic Panasonic Panasonic Indoor coil Speed (Hi/Med/Low) r/min 980/880/ /1200/ /1150/1000 Number of rows Fin type Hydrophilic aluminum Hydrophilic aluminum Hydrophilic aluminum Tube diameter and type mm Ø9.53,Innergroove tube Ø9.53,Innergroove tube Ø9.53,Innergroove tube Air flow (High speed) m 3 /h Sound power level db(a) 39~48 44~50 45~52 Body Dimension (W H D) mm Packing (W H D) mm Net/Gross weight kg 36/42 38/44 51/58 Refrigerant type R410A R410A R410A Throttle type EXV EXV EXV Design pressure MPa Liquid pipe / Gas pipe mm Ø9.53/ Ø15.88 Ø9.53/ Ø15.88 Ø9.53/ Ø15.88 Connecting wire Power wire mm 2 2.5*3 2.5*3 2.5*3 Signal wire mm *2 0.75*2 0.75*2 Drainage water pipe (Outer diameter) mm Ø25 Ø25 Ø25 Controller Standard Remote controller Remote controller Remote controller Optional Wired controller Wired controller Wired controller Operation temp C 16~32 16~32 16~32 Notes: 1) Nominal cooling capacities are based on the following conditions. Outdoor temperature: 35 C DB Return air temperature: 27 C DB, 19 C WB Equivalent piping length: 8m in horizontal 2) Nominal heating capacities are based on the following condition. Outdoor temperature: 7 C DB, 6 C WB Return air temperature: 20 C DB Equivalent piping length: 8m in horizontal 3) Sound pressure level: Semi-anechoic chamber conversion value, measured at a point 1 m in front of the unit at a height of 1.4 m. 4) The above data may be changed without notice for future improvement on quality and performance.
6 New CMV System - Floor ceiling Indoor Unit 5 Model CMV-D140LD/HR1-B CMV-D160LD/HR1-B Power supply V/1PH/50Hz V/1PH/50Hz Capacity Cooling kw Heating kw Power Input kw Model 2*DR LD-8 2*DR LD-8 Fan motor Type DC DC Brand Panasonic Panasonic Indoor coil Speed (Hi/Med/Low) r/min 1300/1150/ /1150/1000 Number of rows 2 2 Fin type Hydrophilic aluminum Hydrophilic aluminum Tube diameter and type mm Ø9.53,Innergroove tube Ø9.53,Innergroove tube Air flow (High speed) m 3 /h Sound power level db(a) 45~52 45~52 Body Dimension (W H D) mm Packing (W H D) mm Net/Gross weight kg 51/58 51/58 Refrigerant type R410A R410A Throttle type EXV EXV Design pressure MPa Liquid pipe / Gas pipe mm Ø9.53/ Ø15.9 Ø9.53/ Ø15.9 Connecting wire Power wire mm 2 2.5*3 2.5*3 Signal wire mm *2 0.75*2 Drainage water pipe (Outer diameter) mm Ø25 Ø25 Controller Standard Remote controller Remote controller Optional Wired controller Wired controller Operation temp C 16~32 16~32 Notes: 1) Nominal cooling capacities are based on the following conditions. Outdoor temperature: 35 C DB Return air temperature: 27 C DB, 19 C WB Equivalent piping length: 8m in horizontal 2) Nominal heating capacities are based on the following condition. Outdoor temperature: 7 C DB, 6 C WB Return air temperature: 20 C DB Equivalent piping length: 8m in horizontal 3) Sound pressure level: Semi-anechoic chamber conversion value, measured at a point 1 m in front of the unit at a height of 1.4 m. 4) The above data may be changed without notice for future improvement on quality and performance.
7 6 4. Dimensions New CMV System - Floor ceiling Indoor Unit A B D C E F Holder Holder Model Body dimension (mm) Installation dimension (mm) A B C D E F CMV-V45LD/HR1-B CMV-V56LD/HR1-B CMV-V71LD/HR1-B CMV-V80LD/HR1-B CMV-V90LD/HR1-B CMV-V112LD/HR1-B CMV-V140LD/HR1-B CMV-V160LD/HR1-B
8 New CMV System - Floor ceiling Indoor Unit 5. Service space There is enough room for installation and maintenance. The ceiling is horizontal, and its structure can endure the weight of the indoor unit. The outlet and the inlet are not impeded, and the influence of external air is the least. The air flow can reach throughout the room. The connecting pipe and drainpipe could be extracted out easily. There is no direct radiation from heaters. 7 >20mm >20mm Install on the floor >600mm Install on the ceiling >600mm >600mm >600mm
9 8 6. Piping diagram New CMV System - Floor ceiling Indoor Unit Flare nut Liquid side Flare nut Liquid side Indoor unit EXV T2 T2B Motor Heat exchanger T1 Notes: 1) T1: Room temperature sensor 2) T2: Temperature sensor of middle heat exchanger 3) T2B: Temperature sensor of heat exchanger outlet 4) EXV: Electrical expansion valve
10 CN3 5 SW2 SW New CMV System - Floor ceiling Indoor Unit 7. Wiring diagram 7.1 Wiring diagram 9 Notes: 1) Color code: RD: Red OR: Orange BK: Black: BR: Brown WH: White PT1 T2B PT2 PT3 T2 T1 CN17 ALARM CN1 PUMP PUMP CN2 RD PTC L CN10 BK N 2) T1: Room temperature sensor 3) T2: Temperature sensor of middle heat exchanger 4) T2B: Temperature sensor of heat exchanger outlet Receive and display light board F01 SW1 LEFT FAN CN7 RIGHT FAN CN8 CN26 REMO_CTRL E21 Controller WATER SWITCH CN4 HEATER IC2 T1 RY4 IC4 C10 10 CN18 CN27 Wire control Water-SW CN23 Duct display EXV CN16 5 DC FAN1 CN29 CN30 OUT SWING IN SWING CN31 5) EXV: Electrical expansion valve 6) Electrical heater is optional, please contact to Chigo s technician for the detail. 5 DC FAN2
11 10 New CMV System - Floor ceiling Indoor Unit Chigo VRF indoor unit connect with card key Connect the remote control terminal on the indoor PCB to the hotel card module. NOTE: The terminal in the hotel card module must be a switch without any voltage/current input to the PCB, otherwise the PCB will be broken.
12 New CMV System - Floor ceiling Indoor Unit 7.2 Dial switches SW1: Capacity switch. Different number in the switch indicates different capacity. It is set in factory; leave it as default setting, 11 HP Capacity (kw) 1.8/ /2.6/ /3.5/ /4.5/ / /6.6/7.1 Code HP Capacity (kw) / /11.0/ /12.5/ /16.0 Code DP SW Name Switch number 1 of SW3 Switch number 4 of SW3 Switch number 2,3 of SW3 Function Auto-restart when power failure switch. / status, operation mode, fan speed, temperature, swing, remote control locked will be recovered. Indoor unit address elimination DP Reserved DP DP DP Dial up to disable Auto-restart function Dial up to erase indoor unit s address. Default setting Setting DP Dial down to enable Auto-restart function (Default setting) DP DP Default setting
13 SW2, only available in heating mode. Name Switch number 1,2 of SW2 New CMV System - Floor ceiling Indoor Unit Function Reserved Setting Default setting Name Switch number 3,4 of SW2 Function Heating temperature compensation value selection. When temperature difference between setting temperature and room temperature is higher than the setting value, indoor fan motor turns off. DO NOT change the default setting without professional guidance. 6 C Default setting 2 C Setting 4 C 8 C
14 New CMV System - Floor ceiling Indoor Unit 13 Name Switch number 5,6 of SW2 Function Temperature selection of turning off fan motor in anti-cold-wind-blow mode. When indoor heat exchanger temperature is lower than the setting value, indoor fan motor turns off. DO NOT change the default setting without professional guidance. 15 C Default setting 20 C Setting 24 C 26 C
15 14 Name Function Switch number 7,8 of SW2 New CMV System - Floor ceiling Indoor Unit Indoor fan motor stopping gap selection in heating mode. When room temperature gets to (set point + temperature value in Switch number 3,4 of SW2), at this moment indoor unit capacity requirement is 0, indoor fan motor turns off for 4 minutes ( this stopping duration time can be changed by below setting). After that indoor fan will run in low speed for 1 minute (this timing is fixed), if indoor unit capacity requirement is still 0, then indoor fan motor keeps off for 4 minutes, and then cycles. DO NOT change the default setting without professional guidance. 4 minutes Default setting 8 minutes Setting 12 minutes 16 minutes SW8, reserved, leave it as default setting (both switches dial down).
16 New CMV System - Floor ceiling Indoor Unit 8 Capacity tables 8.1 Cooling capacity (kw) TC: Total Capacity SC: Sensible Capacity WB: Wet-bulb Temperature DB: Dry-bulb Temperature Indoor temperature ( C WB/DB) Outdoor 14/20 16/23 18/26 19/27 20/28 22/30 24/32 temperature ( C DB) TC SC TC SC TC SC TC SC TC SC TC SC TC SC kw kw kw kw kw kw kw kw kw kw kw kw kw kw
17 16 New CMV System - Floor ceiling Indoor Unit capacity (kw) TC: Total Capacity SC: Sensible Capacity WB: Wet-bulb Temperature DB: Dry-bulb Temperature Indoor temperature ( C WB/DB) Outdoor 14/20 16/23 18/26 19/27 20/28 22/30 24/32 temperature ( C DB) TC SC TC SC TC SC TC SC TC SC TC SC TC SC kw kw kw kw kw kw kw kw kw kw kw kw kw kw
18 New CMV System - Floor ceiling Indoor Unit 17 capacity (kw) TC: Total Capacity SC: Sensible Capacity WB: Wet-bulb Temperature DB: Dry-bulb Temperature Indoor temperature ( C WB/DB) Outdoor 14/20 16/23 18/26 19/27 20/28 22/30 24/32 temperature ( C DB) TC SC TC SC TC SC TC SC TC SC TC SC TC SC kw kw kw kw kw kw kw kw kw kw kw kw kw kw
19 Heating Capacity (kw) New CMV System - Floor ceiling Indoor Unit TC: Total Capacity WB: Wet-bulb Temperature DB: Dry-bulb Temperature Indoor temperature ( C DB) Outdoor temperature ( C) TC TC TC TC TC TC WB DB kw kw kw kw kw kw
20 New CMV System - Floor ceiling Indoor Unit 19 Capacity (kw) TC: Total Capacity WB: Wet-bulb Temperature DB: Dry-bulb Temperature Indoor temperature ( C DB) Outdoor temperature ( C) TC TC TC TC TC TC WB DB kw kw kw kw kw kw
21 20 New CMV System - Floor ceiling Indoor Unit Capacity (kw) TC: Total Capacity WB: Wet-bulb Temperature DB: Dry-bulb Temperature Indoor temperature ( C DB) Outdoor temperature ( C) TC TC TC TC TC TC WB DB kw kw kw kw kw kw
22 New CMV System - Floor ceiling Indoor Unit 21 9 Electrical characteristics Model Indoor unit Power cable MFC Hz Voltage Minimum Maximum L 20m L 50m Grounded Signal cable CMV-D45LD/HR1-B 50Hz V *2.5mm 2 2*4.0mm 2 2.5mm 2 2*0.75 mm 2 CMV-D56LD/HR1-B 50Hz V *2.5mm 2 2*4.0mm 2 2.5mm 2 2*0.75 mm 2 CMV-D71LD/HR1-B 50Hz V *2.5mm 2 2*4.0mm 2 2.5mm 2 2*0.75 mm 2 CMV-D80LD/HR1-B 50Hz V *2.5mm 2 2*4.0mm 2 2.5mm 2 2*0.75 mm 2 CMV-D90LD/HR1-B 50Hz V *2.5mm 2 2*4.0mm 2 2.5mm 2 2*0.75 mm 2 CMV-D112LD/HR1-B 50Hz V *2.5mm 2 2*4.0mm 2 2.5mm 2 2*0.75 mm 2 CMV-D140LD/HR1-B 50Hz V *2.5mm 2 2*4.0mm 2 2.5mm 2 2*0.75 mm 2 CMV-D160LD/HR1-B 50Hz V *2.5mm 2 2*4.0mm 2 2.5mm 2 2*0.75 mm 2 Notes: 1) Minimum: Permitted minimum operating voltage, lower than this value may damage the system 2) Maximum: Permitted maximum operating voltage, higher than this value may damage the system 3) MC: Minimum Current (A) 4) MFC: Maximum Fuse Current (A) 5) L: Total length of cable (m)
23 22 10 Sound levels 10.1 Test condition New CMV System - Floor ceiling Indoor Unit 1 m 1 m Microphone 0.8 m 1.5 m Microphone Notes: Semi-anechoic chamber conversion value, measured at a point 1m in front of the unit at a height of 1.5m 10.2 Test data (Sound pressure level) Model Sound pressure level (db(a)) High speed Medium speed Low speed CMV-D45LD/HR1-B CMV-D56LD/HR1-B CMV-D71LD/HR1-B CMV-D80LD/HR1-B CMV-D90LD/HR1-B CMV-D112LD/HR1-B CMV-D140LD/HR1-B CMV-D160LD/HR1-B Notes: During actual operation, these values are normally somewhat higher as a result of ambient conditions.
24 New CMV System - Floor ceiling Indoor Unit 11 Accessories 11.1 Standard accessories. 23 Item Quantity Shape Usage Installation manual for indoor unit 1 / Must deliver to customer Insulation sheath 2 Thermal insulation for the jointing part of piping Cover board 1 For stopping small animal getting into the unit Hexagonal head bolt 4 For installation use Round shape insulation termination points U shape insulation termination points 6 For wiring 3 For wiring Remote controller 1 For controlling indoor unit Batteries 2 Power to remote controller Left and right hanging holder 2 For hanging indoor unit Nuts, flat gaskets, spring gaskets 4 For hanging indoor unit Drainage connection pipe 1 For connecting draining condensate water pipe to indoor unit Bag 4 For bagging accessories 11.2 Local buy accessories. Specification Item 4.5kW~5.6kW 7.1kW~8.0kW 9.0kW~16.0kW Liquid side copper pipe Ø6.35mm*0.75mm Ø9.53mm*0.75mm Gas side copper pipe Ø12.7mm*0.75mm Ø15.9mm*1.0mm Ø15.9mm*1.0mm Drainage pipe PVC Pipe insulation Thickness 10mm Power cables 2*2.5 mm 2 (When total cable length is 20m) 2*4.0 mm 2 (When total cable length is 50m) Grounded cable 2.5 mm 2 Signal cables 2*0.75 mm 2 (AVP, RVP, RVVP)
25 24 12 Exploded view New CMV System - Floor ceiling Indoor Unit CMV-V45LD/HR1-B, CMV-V56LD/HR1-B, CMV-V71LD/HR1-B, CMV-V80LD/HR1-B, CMV-V90LD/HR1-B No. Part name Quantity No. Part name Quantity 1 Rear cover 1 18 Right mounting plate of evaporator 1 2 Chassis assembly 1 19 Right cover 1 3 E-part box cover 1 20 Right seal plate 1 4 E-part box mat 1 21 Right separating board 1 5 Indoor PCB assembly 1 22 Evaporator component E-part box Left mounting plate of evaporator Indoor PCB Shunt capillary assembly Fan capacitor Air inlet header pipe assembly of evaporator Transformer Evaporator assembly Terminal Right mounting plate of evaporator 1 6 Left seal plate 1 23 Air-out frame component 1 7 Left cover Fixing board assembly for air-out frame 1 8 Left hoisting pate Display film 1 9 Left separating board Ⅰ Display lamp panel 1 10 Motor separating board Vertical step motor 1 11 Wheel volute for slim type Horizontal step motor 1 12 Indoor fan motor Endbearing of louver 2 13 Air inlet grille Intermediate bearing of louver 8 14 Top Cover assembly Guard vane Weld assembly of Water drain pan 1 24 Upper horizontal louver Water outlet rubber cover 1 25 Down horizontal louver 1 16 Supporting board for motor 1 26 EXV supporting board 1 17 Intermediate transverse girder weld assembly 1 18 Right mounting plate of evaporator 1
26 New CMV System - Floor ceiling Indoor Unit CMV-V112LD/HR1-B, CMV-V140LD/HR1-B, CMV-V160LD/HR1-B 25 No. Part name Quantity No. Part name Quantity 1 Right cover 1 16 Top Cover assembly 1 2 Left cover 1 17 Electric box cover 1 3 Right seal plate 1 18 E-parts assy 1 4 Left seal plate Electric box 1 5 Right hoisting plate Indoor PCB 1 6 Left hoisting pate Fan capacitor 2 7 Rat guard Temperature sensors(indoor ) 1 8 Handle Temperature sensors (evaporator ) 1 9 Air out frame assy Transformer Horizontal louver,up Terminal Horizontal louver, down 2 19 Indoor fan motor Display lamp panel 1 20 Wheel volute for slim type Installing box for display panel 1 21 Pipe clamp Foam for air outlet frame 2 22 Left gland for motor shaft sleeve Vertical step motor 1 23 Right gland for motor shaft sleeve Horizontal step motor Motor separating board Horizontal step motor 1 25 Holder for fan motor Display film 1 26 Weld assembly for intermediate transverse girder Endbearing of louver 4 27 Right mounting plate of evaporator Intermediate bearing of louver 8 28 Evaporator Driving lever for louver 2 29 Evaporator into the liquid component Follower lever for louver Shunt capillary component Louver holder Electronic expansion valve, pre-welded components Guard vane Air inlet header pipe assembly of evaporator 1 10 Chassis Single Connector 1 11 Left retaining plate 2 31 Left mounting plate of evaporator 1 12 Right retaining plate 2 32 Weld assembly of Water drain pan 1 13 Filter snap-gauge Water outlet rubber cover 1 14 Air inlet grille 2 33 Remote controller 1 15 Filter 4
Technical Manual. R410A 50Hz Universal Outdoor Series Inverter type. R410A50Hz Universal Outdoor Series Technical Manual LCAC/2016.
Outdoor Unit R410A 50Hz Universal Outdoor Series Inverter type Technical Manual LCAC/2016.1 I GD Chigo Heating & Ventilation Equipment Co., Ltd. Content Part 1. General Information... 1 1. Nomenclature...
More informationTechnical Manual. R410A 50Hz Universal Outdoor Series Inverter type Version. R410A50Hz Universal Outdoor Series Technical Manual LCAC/1.
Outdoor Unit R410A 50Hz Universal Outdoor Series Inverter type Technical Manual 2014 Version LCAC/1.0/201401 I GD Chigo Heating & Ventilation Equipment Co., Ltd. Content PART 1.General Information... 1
More informationDC Inverter Multi-split System Technical Manual - 50Hz/R410a
DC Inverter Multi-split System Technical Manual - 50Hz/R410a A/1/LCAC/2/TM/2.0 General Information Contents Part 1. General Information... 4 1. Features... 4 2. Nomenclature... 6 3. Products Line-up...
More informationR410A50Hz Universal Outdoor Series Technical Manual
Outdoor Unit R410A 50Hz Universal Outdoor Series Technical Manual 2013 Version LCAC/2.0/201308 I GD Chigo Heating & Ventilation Equipment Co., Ltd. Content Content PART 1.General Information... 1 1.Nomenclature...
More informationPart 1 General Information... 1 Part 2 Indoor Units... 7 Part 3 Outdoor Units Part 4 Installation Part 5 Control...
MCAC-UTSM-2008-11 Contents Part 1 General Information... 1 Part 2 Indoor Units... 7 Part 3 Outdoor Units... 88 Part 4 Installation... 127 Part 5 Control... 136 The specifications, designs, and information
More informationDC Inverter Multi-split System Technical Manual - 50Hz/R410a
DC Inverter Multi-split System Technical Manual - 50Hz/R410a A/1/LCAC/2/TM/1.0/201111 Content Contents Part 1. General Information... 1 1. Features... 1 2. Nomenclature... 3 3. Products Line-up... 5 4.
More informationR410A50Hz Universal Outdoor Series Technical Manual
Outdoor Unit R410A 50Hz Universal Outdoor Series Service Manual 2012 Version I GD Chigo Heating & Ventilation Equipment Co., Ltd. Content Content PART 1.General Information... 1 1.Nomenclature... 2 2.Model
More informationWALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER CONTENTS. Models
SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED type Models Indoor unit ASY9USCCW ASY9USCCW ASY12USCCW Outdoor unit AOY9USCC AOY9UFCC AOY12USCC CONTENTS SPECIFICATIONS................................... 1
More informationEngineering Data Book
40VMF 4-Way Cassette Indoor Unit for Variable Refrigerant Flow (VRF) Systems Engineering Data Book Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without
More informationEngineering Data Book
40VMC Compact 4-Way Cassette Indoor Unit for Variable Refrigerant Flow (VRF) Systems Engineering Data Book Manufacturer reserves the right to discontinue, or change at any time, specifications or designs
More informationContent. Part 1 General Information Part 2 Indoor Units Part 3 Outdoor Units Part 4 Installation Part 5 Control...
R410A Tropical Split Type AC Technical Manual Content Content Part 1 General Information... 2 Part 2 Indoor Units... 6 Part 3 Outdoor Units... 88 Part 4 Installation... 120 Part 5 Control... 154 Indoor
More informationMidea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual
Midea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual Midea reserves the right to discontinue, or change specification or designs at any time without notices and without
More informationEngineering Data Book
40VMU Under Ceiling/Floor Indoor Unit for Variable Refrigerant Flow (VRF) Systems Engineering Data Book Manufacturer reserves the right to discontinue, or change at any time, specifications or designs
More information[U] Serie MHB / MHA Manual de Ingeniería
[U] Serie MHB / MHA Evaporadoras Soplladoras de Alltta Presiión Esttáttiica 6..3,, 8 y 12..5 Ton Manual de Ingeniería. - 1 - General Information_MHB 1. Model Names of Indoor/Outdoor Units 2. External Appearance
More informationEngineering Data Book
40VML Low Static Ducted Indoor Unit for Variable Refrigerant Flow (VRF) Systems Engineering Data Book Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without
More informationFan Coil Unit 1. BOSCH Climate Fan Coil Unit
Fan Coil Unit 1 BOSCH Climate 000 Fan Coil Unit 2 Fan Coil Unit Introduction to Bosch Thermotechnology Bosch Thermotechnik GmbH is a leading supplier of resourceefficient heating products and hot water
More informationCASSETTE type INVERTER MULTI AIR CONDITIONER. Models AUY12LBAB AUY14LBAB AOY18LMAK2
INVERTER MULTI AIR CONDITIONER CASSETTE type Models Indoor unit AUY12LBAB AUY14LBAB Outdoor unit AOY18LMAK2 CONTENTS SPECIFICATIONS..................... 1 OUTLINE AND DIMENSIONS........... 2 REFRIGERANT
More informationFloor-Standing Type(E Series)
Floor-Standing Type(E Series) Model: MFE-60CE, MFE-60AE Part 1. Product Features With a spiral shape, the computer-aided simulation designed air passage system can efficiently reduce noise. The Soft touch
More informationIntroduction Part 1 : General Information Part 2: Indoor Units Part 3: Installation Part 4: Control
Introduction Part 1 : General Information Part 2: Indoor Units Part 3: Installation Part 4: Control i Introduction Fan coil unit is a kind of compound device which assemble fan and surface-type coil heating-exchanger
More informationCommercial Air Conditioners. VRF 60Hz V4+S/V4+R/V4+W/Mini VRF
2016 Commercial Air Conditioners VRF 60Hz V4+SV4+RV4+WMini VRF OUTDOOR UNIT LINEUP INDOOR UNIT LINEUP 1.8 2.2 2.8 3.6 4.5 5.6 7.1 8.0 9.0 10.0 11.2 12.5 14.0 16.0 20.0 25.0 28.0 40.0 45.0 OUTDOOR UNIT
More informationAir Conditioner SVC MANUAL(Exploded View)
Internal Use Only http://biz.lgservice.com Air Conditioner SVC MANUAL(Exploded View) Type : Ceiling Concealed Duct MODEL : AMNW24GBGA0 [LMHN240HV] AMNW36GBGA0 [LMHN360HV] CAUTION Before Servicing the unit,
More informationSERVICE MANUAL AIR CONDITIONER SPLIT TYPE
FILE No. A90-961 SERVICE MANUAL AIR CONDITIONER SPLIT TYPE WAY CASSETTE TYPE RAV-133TU-PE/RAV-13A-PE RAV-163TU-PE/RAV-18A-PE Printed in UK Dec 1996 s CONTENTS 1. SPECIFICATION...3. CONSTRUCTION VIEWS...5
More informationCASSETTE type INVERTER MULTI AIR CONDITIONER
INVERTER MULTI AIR CONDITIONER CASSETTE type Models Indoor unit AUY12LBAB AUY14LBAB Outdoor unit AOY18LMAK2 CONTENTS SPECIFICATIONS..................... 1 OUTLINE AND DIMENSIONS........... 2 REFRIGERANT
More informationEngineering Data Book
40VMV Vertical Air Handling Indoor Unit for Variable Refrigerant Flow (VRF) Systems Engineering Data Book Manufacturer reserves the right to discontinue, or change at any time, specifications or designs
More informationAll side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make.
All outdoor units are designed to perform satisfactorily at 52 C, with the option of either top discharge condensing units, with Copeland reciprocating scroll compressors. All top discharge condensing
More informationMINI CHILLER INVERTER H4 Service manual MUENR-H4 (5, 7, 10, 12, 14, 16 kw)
MINI CHILLER INVERTER H4 Service manual MUENR-H4 (5, 7, 10, 12, 14, 16 kw) CL25610 to CL25615 English Content 1. Outdoor units lineup... 2 2. Nomenclature... 3 3.Features... 4 4. Description of main components...
More informationDigital Inverter 4 series 8 & 10HP
E6-H Digital Inverter 4 series 8 & 0HP High static duct type Indoor unit RAV-SM2244DTP-E RAV-SM2804DTP-E Outdoor unit RAV-SM2244AT8-E RAV-SM2804AT8-E Contents. Line up... 2. Indoor unit (High static duct
More informationAmendment Sheet. Nomenclature M 5 AC V 100 C R - F X AA. Code : M5ACV Date : Superceded : M5ACV
Amendment Sheet Code : M5ACV-2005-0002 Date : 08-05-2006 Superceded : M5ACV-2005-0001 Nomenclature Production spec variation Type of ref. connection X : Not applicable Electrical A : 220-240V/1Ph/50Hz
More informationWALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER. Models CONTENTS
SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED type Models Indoor unit ASY9USCCW ASY9USCCW ASY12USCCW Outdoor unit AOY9USCC AOY9UFCC AOY12USCC CONTENTS SPECIFICATIONS.................. 1 OUTLINE AND DIMENSIONS.........
More informationWALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER CONTENTS. Models
SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED type Models Indoor unit ASY9USCCW ASY9USCCW ASY12USCCW Outdoor unit AOY9USCC AOY9UFCC AOY12USCC CONTENTS SPECIFICATIONS.................. 1 OUTLINE AND DIMENSIONS.........
More informationService manual. MIV V4+ Mini
DM12-01.01.05en Service manual MIV V4+ Mini DC INVERTER R410A (~220V, 50Hz, 1Ph) MVUH80A-VA1 Contents Part 1 General Information... 1 Part 2 Outdoor Units... 6 Part 3 Installation... 44 DM12-01.01.05en
More informationMulti Splits Series. DKH Indoor Units DBC Indoor Units DAQ Indoor Units DCD Indoor Units Outdoor Units JOSI-DKH009-N11
Multi Splits Series DKH Indoor Units DBC Indoor Units DAQ Indoor Units DCD Indoor Units Outdoor Units JOSI-DKH009-N11 JOAU-ZCY218-H11 JOSI-DKH012-N11 JOSI-DBC012-N11 JOSI-DAQ012-N11 JOSI-DCD012-N11 JOAU-ZCY327-H11
More informationMANUAL DE INGENIERIA. Part 1 General Information... 1 Part 2 Indoor Units... 6 Part 3 Outdoor Units... 30
MANUAL DE INGENIERIA Evaporadora Sopladora 'MVA' con Condensadora 'MOV' - Blue Star Part 1 General Information... 1 Part 2 Indoor Units... 6 Part 3 Outdoor Units... 30 Part 1 General Information 1. Model
More informationContents. Part 1 General Information...2 Part 2 Outdoor units...7 Part 3 Installation...63 Part 4 Controller...79
MCAC-TSM-2008-02 Contents Part 1 General Information...2 Part 2 Outdoor units...7 Part 3 Installation...63 Part 4 Controller...79 Contents i MCAC-TSM-2008-02 Introduction Introduction Midea Mini Unitary
More informationK*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*
TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS K*ES120 10 NOMINAL TONS EER 8.5 DESCRIPTION These completely assembled dual circuit evaporator blower units include a well-insulated cabinet, a DX cooling
More informationR22 air-cooled modular chiller 50Hz unit. Content
Content 1.Nomenclature... 2 2.Product Schedule... 2. External Appearance... 4.Features... 4 5.Specification... 6 6.Dimension... 10 7.Refrigeration System Sketch Drawing... 14 8.Wiring Diagrams... 16 9.Electric
More informationAqua Mini Full DC Inverter Unitary Chiller 50Hz. Content
MCAC-ATSM-2014-09 Content 1. Outdoor units lineup... 2 2. Nomenclature... 3 3.Features... 4 4. Description of main components... 8 5. Specifications... 10 6. Dimensions... 14 7. Piping Diagram... 15 8.
More informationDESIGN & TECHNICAL MANUAL
AIR CONDITIONER Wall mounted type DESIGN & TECHNICAL MANUAL INDOOR ASYG07KGTA ASYG09KGTA ASYG12KGTA ASYG14KGTA OUTDOOR AOYG07KGCA AOYG09KGCA AOYG12KGCA AOYG14KGCA DR_AS049EF_02 2017.10.11 Notices: Product
More informationCeiling Concealed High Volume Chilled Water Fan Coil Unit (50/60Hz)
Technical Manual Ceiling Concealed High Volume Chilled Water Fan Coil Unit (50/60Hz) Models: MCW1400 MCW1600 Air Flow: 2270-3020m3/h MCW1800 Engineered for flexibility and performance. TM MCW-C/F(High
More informationSPLIT TYPE ROOM AIR CONDITIONER CEILING TYPE (60Hz)
SPLIT TYPE ROOM AIR CONDITIONER CEILING TYPE (60Hz) Indoor unit MS6YF Outdoor unit MR6YF CONTENTS SPECIFICATIONS... OUTLINE AND DIMENSIONS... REFRIGERANT SYSTEM DIAGRAM.... CIRCUIT DIAGRAM... INDOOR PCB
More informationWall Mounted Split Systems
MWM - 2005 Wall Mounted Split Systems Models: MWM 007F/FR MWM 010F/FR MWM 015F/FR MWM 020F/FR MWM 025F/FR MWM 030F/FR Contents Features... 1 Nomenclature... 2 Specifications... 3 Performance Table... 11
More informationTECHNICAL & SERVICE MANUAL
TECHNICAL & SERVICE MANUAL CASSETTE TYPE AIR-CONDITIONER (One-way cassette) FSK-94HF FI-SM-040830 One-way Cassette Air-conditioner Table of Contants Part 1. Product Features 2 Part 2. Specification 3 Part
More informationSERVICE MANUAL CONDENSING UNIT ASE-18AH, ASE-24AH, ASE-36AH, ASE-48AH, ASE-60AH
SERVICE MANUAL CONDENSING UNIT ASE-18AH, ASE-24AH, ASE-36AH, ASE-48AH, ASE-60AH Outdoor Units - appearance 18,000Btu/h 30,000~36,000Btu/h 24,000Btu/h 48,000Btu/h-60,000Btu/h Model Names of Outdoor Units
More informationCEILING type (60Hz) SPLIT TYPE ROOM AIR CONDITIONER CONTENTS. Models
SPLIT TYPE ROOM AIR CONDITIONER CEILING type (60Hz) Models Indoor unit ABU6RSLX Outdoor unit AOU6RLX CONTENTS SPECIFICATIONS....................... OUTLINE AND DIMENSIONS............. REFRIGERANT SYSTEM
More informationSPLIT TYPE ROOM AIR CONDITIONER FLOOR CONSOLE / UNDER CEILING DUAL TYPE
SPLIT TYPE ROOM AIR CONDITIONER FLOOR CONSOLE / UNDER CEILING DUAL TYPE Indoor unit ABYF8LAT ABYF8LAT ABYF8LAT ABYF8LAT ABYF8LBT ABYF8LBT ABYFLAT ABYFLAT ABYFLAT ABYFLAT ABYFLBT ABYFLBT Outdoor unit AOYA8LACL
More informationCASSETTE, FLOOR&CEILING, DUCT UNITS OUTDOOR UNITS
SERVICE MANUAL MULTI COMBI OUTDOOR AND INDOOR UNITS CASSETTE, FLOOR&CEILING, DUCT UNITS OUTDOOR UNITS (36k,42k) COMBINATION TABLE (unit: kw) MC-E18AI MC-E24AI MC-E28AI MC-E36AI 1 model 2 models 2 models
More informationHigh Heat COP. High/Low Stage
SOUND REFRIGERANT ENVIRONMENTALLY PHN5 Product Specifications 15 SEER, 8.0 HSPF, PACKAGE HEAT PUMP, 2-5 TONS Single Phase, 208/230V, Hz. REFRIGERATION CIRCUIT R--410A refrigerant Copper tube/aluminum fin
More informationMODEL: ACWD CEILING CONCEALED Chilled Water Fan Coils Unit
MODEL: ACW200D ACW300D ACW400D ACW500D ACW600D ACW800D ACW900D ACW1000D ACW1200D ACW1400D ACWD-2006 ACWD_2006_Cover.indd 1 CEILING CONCEALED Chilled Water Fan Coils Unit 2006-5-25 17:24:07 Contents Main
More informationCASSETTE type (50Hz) SPLIT TYPE AIR CONDITIONER. Models Indoor unit Outdoor unit
SPLIT TYPE AIR CONDITIONER CASSETTE type (50Hz) Models Indoor unit Outdoor unit RCW-12HA RO-12HB C O N T E N T S SPECIFICATIONS........................................ 1 OUTLINE AND DIMENSIONS..............................
More informationAir Conditioner Service Manual
Air Conditioner Service Manual Большая библиотека технической документации http://splitoff.ru/tehn-doc.html каталоги, инструкции, сервисные мануалы, схемы. 2 MODEL: AC-S7HGB 3 CONTENTS TECHNICAL SPECIFICATION..4
More informationV4 Plus Heat Recovery VRF. Linda Lin Pre-sales Engineer
V4 Plus Heat Recovery VRF Linda Lin Pre-sales Engineer VRF Line-up DC inverter VRFs 2-pipe 3-pipe Combinable Individual Watercooled Mini Heat recovery V5 X 8-88HP V4+S 8-64HP V4+I (side) 20-45kW V4+I (top)
More informationDESIGN & TECHNICAL MANUAL
AIR CONDITIONER Wall mounted type DESIGN & TECHNICAL MANUAL For Extra Cold Climate Area INDOOR ASU18RLF ASU24RLF OUTDOOR AOU18RLXFWH AOU24RLXFWH DR_AS014EF_04 2017.03.10 Notices: Product specifications
More informationSERVICE MANUAL MUFZ-KJ50VE - E1, E2, ER1, ER2, ET1, ET2 MUFZ-KJ35VE OUTDOOR UNIT. No. OBH667. Models HFC
Revision D: MUFZ-KJ25VE - E2, ER2, ET2, MUFZ- KJ35VE - E2, ER2, ET2 and MUFZ- KJ50VE - E2, ER2, ET2 have been added. Please void OBH667 REVISED EDITION-C. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A.
More informationDC Inverter Smart VRF Products(R410A)
DC Inverter Smart VRF Products(R410A) General Description What is DC Inverter Smart? Inverter Smart system is YDS system: 1. With DC inverter compressor; 2. Condensing unit and heat pump type; 3. It is
More informationSERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624. Models HFC. Revision A: MUZ-FH50VE- E1 has been added. Please void OBH624.
SPLIT-TYPE AIR CONDITIONERS Revision A: MUZ-FH50VE- E1 has been added. Please void OBH624. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH624 REVISED EDITION-A Models MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE
More informationSERVICE MANUAL OUTDOOR UNIT. No. OBH530. Models MU-GE50VB- E1 MUH-GE50VB- E1 HFC SPLIT-TYPE AIR CONDITIONERS R410A
SPLIT-TYPE AIR CONDITIONERS OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH530 Models MU-GE50VB- E1 - E1 Indoor unit service manual MS/MSH-GE VB Series (OBH529) CONTENTS 1. TECHNICAL CHANGES 2 2. PART
More informationMUZ-EF25VE - E1 MUZ-EF25VEH - E1 MUZ-EF35VE - E1 MUZ-EF35VEH - E1 MUZ-EF42VE - E1 MUZ-EF50VE - E1 Indoor unit service manual MSZ-EF VE Series (OBH589)
SPLIT-TYPE AIR CONDITIONERS OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH590 Models MUZ-EF25VE - E1 MUZ-EF25VEH - E1 MUZ-EF35VE - E1 MUZ-EF35VEH - E1 MUZ-EF42VE - E1 MUZ-EF50VE - E1 Indoor unit service
More informationCommercial Air Conditioners 2017/2018. VRF 50/60Hz. V5 X Series
Commercial Air Conditioners 2017/2018 VRF 50/60Hz V5 X Series Midea CAC Midea CAC is a key division of the Midea Group, a leading producer of consumer appliances and provider of heating, ventilation and
More informationAIR-CONDITIONER TOSHIBA SERVICE MANUAL SPLIT TYPE, HEAT PUMP COOLING ONLY FILE NO. A Tel: Fax:
Tel: 08 0 www.heronhill.co.uk Fax: 08 80 TOSHIBA Heronhill - for all your Toshiba requirements FILE NO. A90-00 SERVICE MANUAL AIR-CONDITIONER SPLIT TYPE, HEAT PUMP COOLING ONLY WAY CASSETTE TYPE RAV-0TUH--PE
More informationService Manual. Air Conditional
Air Conditional Service Manual Большая библиотека технической документации http://splitoff.ru/tehn-doc.html каталоги, инструкции, сервисные мануалы, схемы. -2 - MODEL: AC-FR30CM -3 - CONTENTS SPECIFICATION...
More informationTWO-PIPE CASSETTE FAN COIL UNIT SERVICE MANUAL. SF-xxxC2 AIR CONDITIONING
TWO-PIPE CASSETTE FAN COIL UNIT SERVICE MANUAL SF-xxxC2 AIR CONDITIONING Compact 4-way cassette FCU 1. External Appearance... 2 2. Features... 2 3. Product lineup... 3 4. Accessories... 3 5. Specifications...
More informationLOW STATIC HYDRONIC DUCTED UNIT
LOW STATIC HYDRONIC DUCTED UNIT PDWA-~AC SERIES PDWA(4R)-~-V-MEDC PDWA(4R)-~-V-MEEU PDWA(R)-~-V PDWA(R+1)-~-P Model cooling capacity( KW) at Medium Speed cooling capacity (KW) at Medium Speed cooling capacity
More informationVARIABLE REFRIGERANT FLOW (VRF) FULL LINE CATALOG
VARIABLE REFRIGERANT FLOW (VRF) FULL LINE CATALOG Spring 2017 Edition BRYANT VRF ADVANTAGES IT TAKES an Efficient Solution...1 What is Variable Refrigerant Flow (VRF)...1 Simultaneous Heating & Cooling...1
More informationБольшая библиотека технической документации каталоги, инструкции, сервисные мануалы, схемы.
Air Conditioner Service Manual Большая библиотека технической документации http://splitoff.ru/tehn-doc.html каталоги, инструкции, сервисные мануалы, схемы. 2 Model: AC-S10CG 3 Content Technical specification..
More informationHydro Kit (For Medium Temperature) SVC MANUAL(Exploded View)
Internal Use nly http://biz.lgservice.com Hydro Kit (For Medium Temperature) SVC MANUAL(Exploded View) MDEL : ARNH10GK2A2 / ARNH04GK2A2 CAUTIN Before Servicing the unit, read the safety precautions in
More informationDAZZLE TM series Cassette Type Fan Coil Unit. FC-NHDU4 Cassette Type Fan Coil Unit 340~2380 m 3 /h
DAZZLE TM series Cassette Type Fan Coil Unit FC-NHDU4 Cassette Type Fan Coil Unit 340~380 m 3 /h Cassette Type Fan Coil Unit Casing Unit Features FC-NHDU4 series is the cassette type fan coil unit of Climaveneta.
More informationService Manual. Multi Split Type Heat Pump Air Conditioners. Applied to: HS-9U2IM_HOS-18U2IM HS-9U11IM_HS-12U11IM_HOS-21U11IM
Service Manual Multi Split Type Heat Pump Air Conditioners Applied to: HS-9U2IM_HOS-18U2IM HS-9U11IM_HS-12U11IM_HOS-21U11IM CONTENT 1. Product features 2. Specification 3. Dimensions 4. Refrigeration cycle
More informationDESIGN & TECHNICAL MANUAL
AIR CONDITIONER Wall mounted type DESIGN & TECHNICAL MANUAL INDOOR ASYG18KLCA ASYG24KLCA OUTDOOR AOYG18KLTA AOYG24KLTA DR_AS069EF_01 2018.03.16 Notices: Product specifications and design are subject to
More informationSERVICE MANUAL OUTDOOR UNIT. No. OBH629 REVISED EDITION-A. Models HFC. Revision A: MUZ-SF25/35/42VE - E2 have been added. Please void OBH629.
SPLIT-TYPE AIR CONDITIONERS Revision A: MUZ-SF25/35/42VE - E2 have been added. Please void OBH629. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH629 REVISED EDITION-A Models MUZ-SF25VE - E1 MUZ-SF42VE
More informationService Manual & Installation Manual
GE Consumer & Industrial Appliances Service Manual & Installation Manual Split System Air Conditioner Model numbers: GE AIR F24 GE AIR F34 GE AIR F41 1 2 3 Introduction and Features Model Remarks GE AIR
More informationSERVICE Manual FREE JOINT MULTI AIR CONDITIONER
FREE JOINT MULTI AIR CONDITIONER INDOOR UNIT MH020FPEA MH023FPEA MH026FPEA MH035FPEA MH052FPEA MH8VP2-09 MH9VP2-07 MH9VP2-2 MH026FKEA MH035FKEA MH052FDEA OUTDOOR UNIT MH8VP2X MH9VP2X MH052FXEA2 MH068FXEA4
More informationLaunching of new SET-FREE Outdoor Units - RAS-FSXN1E Series (8-54HP)-
Suary PAGE: 1 / 47 1 This Technical Bulletin introduces the new outdoor units of the SET-FREE FSXN1E Series (8 to 54HP) using R410A. 2 The details are indicated in the description. Index 1. Main concepts...
More informationDC INVERTER MULTI-SYSTEM AIR CONDITIONER
TECHNICAL & SERVICE MANUAL OUTDOOR UNIT : CU-3KE19NBU CU-4KE24NBU CU-4KE31NBU DC INVERTER MULTI-SYSTEM AIR CONDITIONER Capacity at 0V 19,100 BTU/h,200 BTU/h 30,600 BTU/h Outdoor Model No. CU-3KE19NBU CU-4KE24NBU
More informationPMFY-P-VBM-E. Ceiling cassette (1-way flow type) R410A Data G8 1. SPECIFICATIONS EXTERNAL DIMENSIONS CENTER OF GRAVITY 1-100
Ceiling cassette (-way flow type) RA Data G8 -P-VBM-E. SPECIFICATIONS - 98. EXTERNAL DIMENSIONS - 99 3. CENTER OF GRAVITY -. ELECTRICAL WIRING DIAGRAMS -. SOUND LEVELS -. Sound levels -. NC curve 6. TEMPERATURE/AIRFLOW
More informationSERVICE MANUAL MUZ-SF25VE MUZ-SF25VEH MUZ-SF35VE MUZ-SF35VEH MUZ-SF42VE MUZ-SF42VEH MUZ-SF50VE MUZ-SF50VEH OUTDOOR UNIT. No. OBH629 REVISED EDITION-E
Revision E: The descriptions of the expansion valve coil have been corrected. (11-4.) Please void OBH629 REVISED EDITION-D. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH629 REVISED EDITION-E Models
More informationProduct Specifications. Vertical Floor Consoles By First Co.
NOW WITH 18 GAUGE CABINET AND FACTORY INSTALLED SERVICE SWITCH Product Specifications VFB Series VSB Series VCB Series Vertical Console Fan Coils 300-00 CFM Vertical Floor Consoles By First Co. VFB Series
More informationSUBMITTAL M4MCW1509A-SUB-1C. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA TAG:
M4MCW1509A-SUB-1C TAG: 15 SERIES SUBMITTAL Specifications Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA MODEL - Cooling Only RATED Volts/PH Frequency (Hz) Rated Cooling Capacity
More informationSERVICE MANUAL MUZ-EF25VE MUZ-EF25VEH MUZ-EF35VE MUZ-EF35VEH MUZ-EF42VE MUZ-EF50VE. No. OBH590 REVISED EDITION-F. Models HFC
Revision F: The descriptions of the expansion valve coil have been corrected. (11-4.) Please void OBH590 REVISED EDITION-E. OUTDOOR INDOOR UNIT UNIT SERVICE MANUAL HFC utilized R410A. OBH590 REVISED EDITION-F
More informationHGF / HHF Series REFRIGERANT. SM HGFHHF 1-A.1 GB March Version:2
HGF / HHF Series Indoor Units Outdoor Units AWSI-HGF009-H11 AWSI-HHF009-H11 AWAU-YGF009-H11 AWSI-HGF012-H11 AWSI-HHF012-H11 AWAU-YGF012-H11 AWSI-HGF018-H11 AWSI-HHF018-H11 AWAU-YGF018-H11 AWSI-HGF024-H11
More informationFLOOR CONSOLE / UNDER CEILING DUAL type
SPLIT TYPE ROOM AIR CONDITIONER FLOOR CONSOLE / UNDER CEILING DUAL type Models Indoor unit ABU8RULX ABURULX Outdoor unit AOU8RLX AOURLX CONTENTS SPECIFICATIONS... OUTLINE AND DIMENSIONS... REFRIGERANT
More informationTECHNICAL MANUAL CX(E) SPLIT SYSTEMS. Tel: Fax:
TECHNICAL MANUAL CX(E) SPLIT SYSTEMS CONTENTS INDEX PART NUMBERS, OPTIONS, UNIT COMBINATIONS, DIMENSIONS & WEIGHTS 3 PERFORMANCE DATA & AIR FLOW 4 SOUND POWER AND SOUND PRESSURE LEVELS 5 ELECTRICAL DATA
More informationMVD. Cassette 4 Ways FCU DC Service manual MUCS-W7. CL04417 to CL04419 English.
MVD Cassette 4 Ways FCU DC Service manual MUCS-W7 www.mundoclima.com CL04417 to CL04419 English 4-way cassette 1. External Appearance... 2 2. Features... 2 3. Product lineup... 3 4. Accessories... 4 5.
More informationSUBMITTAL M4MCW1509A-SUB-1B. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA TAG:
M4MCW1509A-SUB-1B TAG: 15 SERIES SUBMITTAL Specifications Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA MODEL - Cooling Only RATED Volts/PH Frequency (Hz) Rated Cooling Capacity
More informationCASSETTE TYP FANCOIL UNIT SERVICE MANUAL
CASSETTE TYP FANCOIL UNIT SERVICE MANUAL (GC201109-I) Contents PRODUCT...2 1. MODELS LIST...2 2. NOMENCLATURE OF THE UNIT...3 3. FUNCTION...3 4. PRODUCT DATA...4 CONTROL...10 1. WIRELESS REMOTE CONTROLLER...10
More informationService Manual. Air Conditional
Air Conditional Service Manual Большая библиотека технической документации http://splitoff.ru/tehn-doc.html каталоги, инструкции, сервисные мануалы, схемы. -2 - MODEL: AC-FR30HM -3 - CONTENTS SPECIFICATION...
More informationMHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH
MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH 318 MHNCCX NOMENCLATURE BREAKDOWN 4-Pipe Heat/Cool Ceiling Concealed Fan Coil MHNCCW- XX - XX Ceiling Concealed
More informationSERVICE MANUAL IOS629C2V01 IOS736C2V01 IUS0736C21 ICS0629C21 ICS0736C21 AIR CONDITIONER
SERVICE MANUAL IOS629C2V01 IOS736C2V01 IUS0736C21 ICS0629C21 ICS0736C21 AIR CONDITIONER i Contents CONTENTS Part 1 General Information... 1 Part 2 Indoor Units... 5 Part 3 Outdoor Units... 32 Part 4 Installation...
More informationSKYPAK II Heating & Cooling Self Contained Packages
SKYPAK II Heating & Cooling Self Contained Packages SKYPAK II gives you a complete airconditioning and heating system as an all-in-one package unit. Designed for conventional through-the-wall installation
More informationSUBMITTAL M4MLW1809A-SUB-1A. Specifications 18 SERIES. Single Zone Mini-Split Inverter System M4MLW1809A1N0A M4TLS1809A11NA TAG:
M4MLW1809A-SUB-1A TAG: 18 SERIES SUBMITTAL Specifications Single Zone Mini-Split Inverter System M4MLW1809A1N0A M4TLS1809A11NA MODEL - Heat Pump Only RATED Volts/PH Frequency (Hz) Rated Cooling / Heating
More informationSUBMITTAL M4MHW1509A-SUB-1B. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MHW1509A1N0A M4THS1509A11NA TAG:
M4MHW1509A-SUB-1B TAG: 15 SERIES SUBMITTAL Specifications Single Zone Mini-Split Inverter System M4MHW1509A1N0A M4THS1509A11NA 2017 Ingersoll Rand All Rights Reserved MODEL - Heat Pump Only RATED Volts/PH
More informationSubmittal Sheet AIR-CON MULTI-SPLIT II. High-Wall Cassette Duct Floor and Ceiling AMTCM4H4R18
Submittal Sheet Submitted for: Approval Record Job Name: Contractor: Engineer: Date: Location: Tag: AIR-CON MULTI-SPLIT II Indoor Units Outdoor Unit High-Wall Cassette Duct Floor and Ceiling AMTCM4H4R18
More informationSERVICE MANUAL MUZ-DM25VA - E1, ER1, ET1 MUZ-DM35VA - E1, ER1, ET1 OUTDOOR UNIT. No. OBH751. Models HFC R410A
OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. Models MUZ-DM25VA - E1, ER1, ET1 MUZ-DM35VA - E1, ER1, ET1 Indoor unit service manual MSZ-DM VA Series (OBH750) CONTENTS 1. TECHNICAL CHANGES 2 2. PART NAMES
More informationService Manual. Compact Series REFRIGERANT R407C R22 COOLING ONLY HEAT PUMP. Indoor Units Outdoor Units IOD 7 CON 7 IOD 9 CON 9 IOD 12 CON 12
Service Manual Compact Series Indoor Units Outdoor Units IOD 7 CON 7 IOD 9 CON 9 IOD 12 CON 12 REFRIGERANT R407C R22 COOLING ONLY HEAT PUMP SEPTEMBER - 2005 LIST OF EFFECTIVE PAGES LIST OF EFFECTIVE PAGES
More informationComplete HVAC Capability. Central Station Air Handling Units. Publication No. WT-CSX-0616A
Publication No. WT-CSX-0616A Central Station Air Handling Units Complete HVAC Capability Horizontal Draw-Thru to Size 65 Vertical Draw-Thru to Size 50 1000 to 60,000 CFM Forward Curved or Airfoil Wheels
More informationTECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 123A FILE NO. SA 123A REFERENCE NO. SM700513
TECHNICAL & SERVICE MANUAL SA 123A FILE NO. WINDOW TYPE AIR CONDITIONER Model No. Product Code No. Destination SA-123A 1 851 006 95 Australia SA 123A REFERENCE NO. SM700513 IMPORTANT! Please Read Before
More information1. MODELS LIST NOMENCLATURE FEATURES PRODUCT DATA FAN CHARACTERISTICS CLEARANCE DATA...
FIXED FREQUENCY U-MATCH AIR CONDITIONERS TECHNICAL SALES GUIDE Capcity Range: 18000~ 60000 Bth h T3R2250Hz CONTENTS 1. MODELS LIST... 3 2. NOMENCLATURE... 4 3. FEATURES... 5 4. PRODUCT DATA... 9 5. FAN
More informationSERVICE MANUAL MUZ-GE25VA - E1 MUZ-GE25VAH - E1 MUZ-GE35VA - E1 MUZ-GE35VAH - E1 MUZ-GE42VA - E1 MUZ-GE42VAH - E1 MUZ-GE50VA - E1 MUZ-GE50VAH - E1
SPLIT-TYPE AIR CONDITIONERS Revision A: MUZ-GE42/50VA(H) - E1 has been added. Please void OBH516. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH516 REVISED EDITION-A Models MUZ-GE25VA - E1 MUZ-GE25VAH
More informationHorizontal Water Source Heat Pumps And Cooling Only Unit
MWH-B-2005 Horizontal Water Source Heat Pumps And Cooling Only Unit Models: MWH MWH MWH MWH MWH 011 B/BR MWH 012 B/BR MWH 015 B/BR MWH 020 B/BR MWH 025 B/BR MWH 030 B/BR 040 B/BR 050 B/BR 060 B/BR 070
More informationFLOOR CONSOLE / UNDER CEILING DUAL type (60Hz)
SPLIT TYPE ROOM AIR CONDITIONER FLOOR CONSOLE / UNDER CEILING DUAL type (60Hz) Models Indoor unit MSYF Outdoor unit MRUYF CONTENTS SPECIFICATIONS... OUTLINE AND DIMENSIONS... REFRIGERANT SYSTEM DIAGRAM...
More informationAir Conditioner Service Manual
Air Conditioner Service Manual Большая библиотека технической документации http://splitoff.ru/tehn-doc.html каталоги, инструкции, сервисные мануалы, схемы. 2 MODEL: AC-S13CEGL1 3 CONTENTS TECHNICAL SPECIFICATION...
More information