Multi V Air Conditioner SVC MANUAL(Exploded View)
|
|
- Caren Hoover
- 6 years ago
- Views:
Transcription
1 Internal Use nly Multi V Air Conditioner SVC MANUAL(Exploded View) MDEL : ARNU183TL*2 ARNU243TL*2 CAUTIN Before Servicing the unit, read the safety precautions in General SVC manual. nly for authorized service personnel.
2 1. Specification Cooling Capacity Heating Capacity Casing Type Model Body Dimensions (WxDxH) Front Panel Coil Unit kw kcal/h Btu/h kw kcal/h Btu/h mm inch mm inch Rows x Columns x FPI Face Area m 2 (ft 2 ) Type Motor utput x Number W Running Current A Fan Air Flow Rate(H/M/L) CMM cfm Drive Motor type Temperature Control Sound Absorbing Thermal Insulation Material Safety Device Liquid Side mm(inch) Pipe Connections Gas Side mm(inch) Drain Pipe(Internal Dia.) mm(inch) Net Weight Body kg(lbs) Noise Level(Sound Press, 1.5m, H/M/L) db(a) Power Supply Ø, V, Hz Refrigerant Control Power cable Transmission cable Panel Color Panel Name(Acc'y) ARNU183TL* ,800 19, ,400 21,500 Galvanized Steel Plate 830x550x x21.6x8.9 1,050x640x x25.2x1.1 2x11x (1.4) Cross Flow Fan 20x2 0.18x2 13/12/10 459/424/353 Direct BLDC Microprocessor, Thermostat for cooling and heating Foamed polystrene Fuse Ø6.35(1/4) Ø12.7(1/2) 25.0(1) 22(48.5) 40/35/30 1,208/230,60 EEV CV1.5 x 3C CVVSB 1.25 x 2C Morning fog PTHL* 2Way Ceiling Cassette * Model Name A:Basic, C:Plasma ARNU243TL* ,100 24, ,900 27,300 Galvanized Steel Plate 830x550x x21.6x8.9 1,050x640x x25.2x1.1 2x11x (1.4) Cross Flow Fan 20x2 0.18x2 17/15/13 601/530/459 Direct BLDC Microprocessor, Thermostat for cooling and heating Foamed polystrene Fuse Ø9.52(3/8) Ø15.88(5/8) 25.0(1) 22(48.5) 42/37/32 1,208/230,60 EEV CV1.5 x 3C CVVSB 1.25 x 2C Morning fog PTHL* Notes: 1. Capacities are based on the following conditions: Cooling Indoor temp. 27 C[80.6 F]DB/ 19 C[66.2 F]WB utdoor temp. 35 C[95 F]DB/ 24 C[75.2 F]WB Interconnecting Piping Length 7.5m(24.6ft) Level Difference of Zero Heating Indoor temp. 20 C[68 F]DB/ 15 C[59 F]WB utdoor temp. 7 C[44.6 F]DB/ 6 C[42.8 F]WB Interconnecting Piping Length 7.5m(24.6ft) Level Difference of Zero 2. Capacities are Net Capacities 3. Due to our policy of innovation some specifications may be changed without prior notification 4. To be added for more available Models 5. EEV : Electronic Expansion Valve Conversion Formula kcal/h= kw x 860 Btu/h = kw x 3412 cfm = m 3 /min x 35.3 l/s = CMM x 1000/60 nly for training and service purposes 2 LGE Internal Use nly
3 2. List of Functions Category Air flow Air purifying Installation Reliability Convenience Individual control Special function kit Function Air supply outlet Airflow direction control(left & right) Airflow direction control(up & down) Auto swing(left & right) Auto swing(up & down) Airflow steps(fan/cool/heat) Chaos swing Chaos wind(auto wind) Jet cool(power wind) Swirl wind Deodorizing filter Plasma air purifier Prefilter(washable / antifungus) Drain pump E.S.P. control Electric heater(operation) High ceiling operation Hot start Self diagnosis Soft dry operation Auto changeover Auto cleaning Auto operation(artificial intelligence) Auto restart operation Child lock Forced operation Group control Sleep mode Timer(on/off) Timer(weekly) Two thermistor control Standard wired remote controller Wide Character wired remote controller Picto wired remote controller Deluxe wired remote controller Simple wired remote controller Wired remote controller(for hotel use) Wireless remote controller(simple) Wireless LCD remote control Zone control CTIE Electro thermostat ARNU183TL*2, ARNU243TL*2 2 auto 4/5/4 ption (only heat recovery) (only heat pump or cooling only) : Applied : Not applied : No relation ption : Model name & price are different according to options, and assembled in factory with main unit. : Installed at field, ordered and purchased separately by the corresponding model name, supplied with separate package. nly for training and service purposes 3 LGE Internal Use nly
4 3. Piping Diagrams Heat Exchanger EEV Filter :Cooling :Heating Th3 C.F.F Th2 Filter Th1 lndoor unit Refrigerant pipe connection port diameter Model ARNU183TL*2 ARNU243TL*2 Gas Ø12.7(1/2) Ø15.88(5/8) [unit: mm(inch)] Liquid Ø6.35(1/4) Ø9.52(3/8) LC. Th1 Th2 Th3 Description Room thermistor Pipe in thermistor Pipe out thermistor nly for training and service purposes 4 LGE Internal Use nly
5 4. Wiring Diagrams CN_MTR CN_EEV CN_FLAT CN_DISP CN_PITIN CN_RM CN_PIPE/IN CN_PIPE/UT CN_D/PUMP CN_PWER CN_VANE2 CN_CM CN_GRILL CN_VANE1 CN_HVB CN_REM Dip Switch Setting N FF Remarks SW3 GRUP Master Slave Group Control setting using Wired Remote Controller SW4 DRY CNTACT Variable Auto Dry contact mode setting 1. Duct model. FF : Default(not operate continuosly ). N : Fan operate continuosly SW5 ETRA 1 FF N 2. Cassette Model : No Function 3. Ceiling Suspended Model. FF : Ceiling(default). N : Floor CAUTIN For Multi V Model, Dip Switch 1,2,5,6,7,8 must be set FF That dip switch is used for the other model. nly for training and service purposes 5 LGE Internal Use nly
6 5. Exploded View TL (Standard model) W0FZZ D E W C B A G A THERMISTR B THERMISTR C THERMISTR W50011 Thermistor A Air Housing color : yellow Thermistor B Eva. in Housing color : white Thermistor C Eva. out Housing color : red nly for training and service purposes 6 LGE Internal Use nly
7 TL (Plasma model) W0FZZ D E W C B A G A THERMISTR B THERMISTR C THERMISTR W50011 Thermistor A Air Housing color : yellow Thermistor B Eva. in Housing color : white Thermistor C Eva. out Housing color : red nly for training and service purposes 7 LGE Internal Use nly
8 P/N : MFL MAY, 2008
Multi V Air Conditioner SVC MANUAL(Exploded View)
Internal Use nly http://biz.lgservice.com Multi V Air Conditioner SVC MANUAL(Exploded View) MDEL : ARNU18GTL*2 ARNU24GTL*2 CAUTIN Before Servicing the unit, read the safety precautions in General SVC manual.
More informationMulti V Air Conditioner SVC MANUAL(Exploded View)
Internal Use nly http://biz.lgservice.com Multi V Air Conditioner SVC MANUAL(Exploded View) MDEL : ARNU09GTL*4 ARNU12GTL*4 ARNU18GTL*4 ARNU24GTL*4 CAUTIN Before Servicing the unit, read the safety precautions
More informationMulti V Air Conditioner SVC MANUAL(Exploded View)
Internal Use nly http://biz.lgservice.com Multi V Air Conditioner SVC MANUAL(Exploded View) MDEL : ARNU07GSE*2 ARNU09GSE*2 ARNU12GSE*2 ARNU15GSE*2 ARNU18GS5*2 ARNU24GS5*2 CAUTIN Before Servicing the unit,
More informationMulti V Air Conditioner SVC MANUAL(Exploded View)
Internal Use nly http://biz.lgservice.com Multi V Air Conditioner SVC MANUAL(Exploded View) MDEL : ARNU183NJA2 ARNU243NJA2 ARNU303NJA2 ARNU363NJA2 ARNU423NKA2 ARNU483NKA2 ARNU543NKA2 CAUTIN Before Servicing
More informationMulti V Air Conditioner SVC MANUAL(Exploded View)
Internal Use nly http://biz.lgservice.com Multi V Air Conditioner SVC MANUAL(Exploded View) MDEL : ARNU05GL1G4 ARNU15GL2G4 ARNU07GL1G4 ARNU18GL2G4 ARNU09GL1G4 ARNU21GL3G4 ARNU12GL2G4 ARNU24GL3G4 CAUTIN
More informationMulti V Air Conditioner SVC MANUAL(Exploded View)
Internal Use nly http://biz.lgservice.com Multi V Air Conditioner SVC MANUAL(Exploded View) MDEL : ARNU07GQAA2 ARNU09GQAA2 ARNU12GQAA2 ARNU15GQAA2 CAUTIN Before Servicing the unit, read the safety precautions
More informationMulti V Air Conditioner SVC MANUAL(Exploded View)
Internal Use nly http://biz.lgservice.com Multi V Air Conditioner SVC MANUAL(Exploded View) MDEL : ARNU07GTU*4 ARNU09GTU*4 ARNU12GTU*4 ARNU18GTT*4 ARNU24GTT*4 CAUTIN Before Servicing the unit, read the
More informationMulti V Air Conditioner SVC MANUAL(Exploded View)
Internal Use nly http://biz.lgservice.com Multi V Air Conditioner SVC MANUAL(Exploded View) MDEL : ARNU05GSB*4 ARNU07GSB*4 ARNU09GSB*4 ARNU12GSB*4 ARNU15GSB*4 ARNU18GSC*4 ARNU24GSC*4 CAUTIN Before Servicing
More informationMulti Zone Air Conditioner SVC MANUAL (Exploded View)
Multi Zone Air Conditioner SVC MANUAL (Exploded View) CAUTIN Before Servicing the unit, read the safety precautions in General SVC manual. nly for authorized service personnel. MDEL: MD12Y3JM 960-920-06
More informationMulti Zone Air Conditioner SVC MANUAL (Exploded View)
Multi Zone Air Conditioner SVC MANUAL (Exploded View) CAUTIN Before Servicing the unit, read the safety precautions in General SVC manual. nly for authorized service personnel. MDEL: MD18Y3JM 960-920-07
More informationHydro Kit (For Medium Temperature) SVC MANUAL(Exploded View)
Internal Use nly http://biz.lgservice.com Hydro Kit (For Medium Temperature) SVC MANUAL(Exploded View) MDEL : ARNH10GK2A2 / ARNH04GK2A2 CAUTIN Before Servicing the unit, read the safety precautions in
More information(60Hz/R410A) 6CIM0-02B (Replace: 6CIM0-02A)
(60Hz/R410A) 6CIM0-02B (Replace: 6CIM0-02A) (60Hz/R410A) 6CIM0-02B (Replace: 6CIM0-02A) CONTENTS Part 1 General information Part 2 Product data Part 3 Design and installation Part 4 Special parts 2 Introduction
More informationAir Conditioner SVC MANUAL(Exploded View)
Internal Use nly http://biz.lgservice.com Air Conditioner SVC MANUAL(Exploded View) MDEL : AUUW423D[LUU425HV] CAUTIN Before Servicing the unit, read the safety precautions in General SVC manual. nly for
More informationRoom Air Conditioner SVC MANUAL(Exploded View)
Internal Use nly http://biz.lgservice.com Room Air Conditioner SVC MANUAL(Exploded View) MDEL : LSN090HSV4 / LSU090HSV4 (ASNW09GB1B0 / ASUW093BUB6) LSN120HSV4 / LSU120HSV4 (ASNW12GB1B0 / ASUW123BUB6) LSN180HSV4
More informationRoom Air Conditioner SVC MANUAL(Exploded View)
Internal Use nly http://biz.lgservice.com Room Air Conditioner SVC MANUAL(Exploded View) MDEL : AS-W1838*H0 (LAN185HV / LAU185HV) AS-W2438*H0 (LAN245HV / LAU245HV) CAUTIN Before Servicing the unit, read
More informationWall Mounted Air Conditioner SVC MANUAL(Exploded View)
Internal Use Only http://biz.lgservice.com Wall Mounted Air Conditioner SVC MANUAL(Exploded View) MODEL : AMNW07GDBL1 [LMN077HVT] AMNW09GDBL1 [LMN097HVT] AMNW12GDBL1 [LMN127HVT] AMNW15GDBL1 [LMN157HVT]
More informationAir Conditioner SVC MANUAL(Exploded View)
Internal Use Only http://biz.lgservice.com Air Conditioner SVC MANUAL(Exploded View) Type : Ceiling Concealed Duct MODEL : AMNW24GBGA0 [LMHN240HV] AMNW36GBGA0 [LMHN360HV] CAUTION Before Servicing the unit,
More informationRoom Air Conditioner SVC MANUAL(Exploded View)
Internal Use Only http://biz.lgservice.com Room Air Conditioner SVC MANUAL(Exploded View) MODEL : LSN090HYV / LSU090HYV LSN120HYV / LSU120HYV CAUTION Before Servicing the unit, read the safety precautions
More informationSVC Manual(Exploded View)
SVC Manual(Exploded View) Model : M18YJ M18CJ M24CJ Product Specifications System 18k 18k 24k System M18YJ M18CJ M24CJ FAC Model Name Outdoor Unit MR18Y3J MR18C3J MR24C3J Indoor Unit MW18Y3J MW18C3J MW24C3J
More informationLG Air Conditioner SVC MANUAL(Exploded View) Type: Ceiling Concealed Duct(Low Static)
Internal Use Only http://biz.lgservice.com LG Air Conditioner SVC MANUAL(Exploded View) Type: Ceiling Concealed Duct(Low Static) MODEL : ABNH09GL1A2 [CB09L N12 / CB09L N12A0] ABNH12GL2A2 [CB12L N22 / CB12L
More informationRoom Air Conditioner SVC MANUAL(Exploded View)
Internal Use Only http://biz.lgservice.com Room Air Conditioner SVC MANUAL(Exploded View) MODEL : AS-W183CSA5 AS-W243CSA5 CAUTION Before Servicing the unit, read the safety precautions in General SVC manual.
More informationSingle Zone Air Conditioner SVC MANUAL(General)
Single Zone Air Conditioner SVC MANUAL(General) CAUTION Before Servicing the unit, read the safety precautions in General SVC manual. Only for authorized service personnel. 960-914-06 Air Conditioner Service
More informationAir-to-Water Heat Pump (50Hz, R410A) 5BPM0-01G (Replace: 5BPM0-01F)
Air-to-Water Heat Pump (50Hz, R410A) 5BPM0-01G (Replace: 5BPM0-01F) P/No. : MFL66101106 CONTENTS Part 2. Design and installation Part 3. Accessories 1. Features 2. Nomenclature 3. List of functions 4.
More informationAir-to-Water Heat Pump (50Hz, R410A) 5BPM0-01J (Replace: 5BPM0-01H)
Air-to-Water Heat Pump (50Hz, R410A) 5BPM0-01J (Replace: 5BPM0-01H) P/No. : MFL66101106 CONTENTS Part 2. Design and installation Part 3. Accessories 1. Features 2. Nomenclature 3. List of functions 4.
More informationSingle Zone Air Conditioner SVC MANUAL (Exploded View)
Single Zone Air Conditioner SVC MANUAL (Exploded View) CAUTION Before Servicing the unit, read the safety precautions in General SVC manual. Only for authorized service personnel. MODEL: MR36UY3J 960-920-10
More informationEasy to service. Up to 9 indoor units can be connected
MULTI V MINI can be easily installed in small offices and shops. Designed for low-noise operation, it creates a pleasant air conditioned environment. Easy to service 1 Inner SVC valve - 4 Way piping is
More informationAir Conditioning System
For continual product development, LG reserves the right to change specifications without notice. LG MULTI V Air Conditioning System 200 Air Conditioning System 200 Air Conditioning System Enjoy a clean
More informationLG Commercial Air Conditioners 2010 Enjoy Clean, Quiet, and Comfortable Air Conditioning with LG.
Features _ icon Weekly Program Turbo Fan High Head Drain Pump Low Standby Power Auto Restart Central Controller(Accessory) For continual product development, LG reserves the right to change specifications
More informationduct-free air conditioning systems Art cool inverter flex multi-split
engineering and specifications Guide duct-free air conditioning systems Art cool inverter flex multi-split floor standing ceiling cassette PTAC PTHP through-the-wall innovative comfort solutions 1 AT LG,
More informationCommercial Air Conditioners. VRF 60Hz V4+S/V4+R/V4+W/Mini VRF
2016 Commercial Air Conditioners VRF 60Hz V4+SV4+RV4+WMini VRF OUTDOOR UNIT LINEUP INDOOR UNIT LINEUP 1.8 2.2 2.8 3.6 4.5 5.6 7.1 8.0 9.0 10.0 11.2 12.5 14.0 16.0 20.0 25.0 28.0 40.0 45.0 OUTDOOR UNIT
More informationEngineering Data Book
40VML Low Static Ducted Indoor Unit for Variable Refrigerant Flow (VRF) Systems Engineering Data Book Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without
More informationWORLD LARGEST Air Conditioners Manufacturer PRODUCT CATALOGUE GREE MALAYSIA SDN BHD ( M)
WORLD LARGEST Air Conditioners Manufacturer PRODUCT CATALOGUE GREE MALAYSIA SDN BHD (1132718-M) WALL MOUNTED SPLIT UNIT LOMO N Series WALL MOUNTED SPLIT UNIT R410A Eco-friendly Refrigerant Quiet Fast Cooling
More informationCeiling Cassette Type Single-Zone Air Conditioning
Ceiling Cassette Type Single-Zone Air Conditioning DMC24CA-1 DMC36CA-1 Before servicing the unit, read the safety precautions in this manual. nly for authorized service personnel. TABLE F CNTENTS Table
More informationENGiNEERiNG AND SPECiFiCATiONS GuiDE
ENGiNEERiNG AND SPECiFiCATiONS GuiDE DuCT-FREE AiR CONDiTiONiNG SySTEmS ART COOL inverter FLEx multi-split FLOOR STANDiNG CEiLiNG CASSETTE PTAC PTHP THROuGH-THE-WALL LG Electronics, Air Conditioning Division
More informationLG Commercial Air Conditioners 2010 Enjoy Clean, Quiet, and Comfortable Air Conditioning with LG.
Features _ icon Weekly Program Turbo Fan High Head Drain Pump Low Standby Power Auto Restart Central Controller(Accessory) For continual product development, LG reserves the right to change specifications
More informationSVC Manual(Exploded View)
SVC Manual(Exploded View) Model : M18YJ M18CJ M24CJ FAC P/no : 960-920-01 Product Specifications System 18k 18k 24k System M18YJ M18CJ M24CJ FAC Model Name Outdoor Unit MR18Y3J MR18C3J MR24C3J Indoor Unit
More informationENGiNEERiNG AND SPECiFiCATioNS GuiDE
ENGiNEERiNG AND SPECiFiCATioNS GuiDE DuCT-FREE AiR CoNDiTioNiNG SySTEmS ART CooL inverter FLEx multi-split FLooR STANDiNG CEiLiNG CASSETTE PTAC PTHP THRouGH-THE-WALL LG Electronics, Air Conditioning Division
More informationHighly Efficient,Powerful Heating and Cooling.
AIR-COOLED ROOFTOP PACKAGED AIR CONDITIONERS Series HEAT PUMP PRHG-8,,,20 Cooling Capacity kw Heating Capacity kw PRHG-8 PRHG- PRHG- PRHG-20 PRHG-8 PRHG- PRHG- PRHG-20 23.8 29.7.3 60.8 23.0 32.0 45.5 61.2
More informationLG Commercial Air Conditioners 2010 Enjoy Clean, Quiet, and Comfortable Air Conditioning with LG.
Features _ icon Weekly Program Turbo Fan High Head Drain Pump Low Standby Power Auto Restart Central Controller(Accessory) For continual product development, LG reserves the right to change specifications
More information(Non-Inverter & Inverter) R410A
LG Commercial Air Conditioner Sinlge Split Type (Non-Inverter & Inverter) R410A Distributed by LG Electronics www.lg.com http://partner.lge.com Copyright 2015 LG Electronics. All rights reserved. Non-Inverter
More informationWORLD LARGEST Air Conditioners Manufacturer PRODUCT CATALOGUE GREE MALAYSIA SDN BHD ( M)
WORLD LARGEST Air Conditioners Manufacturer PRODUCT CATALOGUE GREE MALAYSIA SDN BHD (3278-M) BORA Series WALL MOUNTED SPLIT UNIT NON-INVERTER Series Concealed display Hidden temperature display on a classy
More informationLG Commercial Air Conditioners 2010 Enjoy Clean, Quiet, and Comfortable Air Conditioning with LG.
Features _ icon Weekly Program Turbo Fan High Head Drain Pump Low Standby Power Auto Restart Central Controller(Accessory) For continual product development, LG reserves the right to change specifications
More informationINDOOR UNIT PRODUCT OVERVIEW
PI_MultiV_IDU_ProductOverview 6 INDOOR UNIT PRODUCT OVERVIEW Ducted 7,500 to 95,900 Btu/h Ceiling Cassettes 5,500 to 8,00 Btu/h Ceiling Suspended 9,00 and,00 Btu/h Wall-Mounted 5,500 to 5,500 Btu/h Floor
More informationAUS-DU112. New South Wales / Head Office 2 Wonderland Drive EASTERN CREEK NSW 2766 PH : FAX :
AUSDU112 New South Wales / Head Office 2 Wonderland Drive EASTERN CREEK NSW 2766 PH : 0288054000 FAX : 0288054248 Queensland 23 Terrace Place MURARRIE QLD 4172 PH : 0739089000 FAX : 0733994179 Victoria
More informationDESIGN & TECHNICAL MANUAL
AIR CONDITIONER Wall mounted type DESIGN & TECHNICAL MANUAL For Extra Cold Climate Area INDOOR ASU18RLF ASU24RLF OUTDOOR AOU18RLXFWH AOU24RLXFWH DR_AS014EF_04 2017.03.10 Notices: Product specifications
More informationAIR-TO-WATER HEAT PUMP (50Hz/R410A) 5BPU0-02A(5BPU0-01A)
AIR-TO-WATER HEAT PUMP (50Hz/R410A) 5BPU0-02A(5BPU0-01A) AIR-TO-WATER HEAT PUMP (50Hz/R410A) CONTENTS Part 1. Introduction Part 2. Indoor Unit(Hydro kit) Part 3. Outdoor Unit Part 4. Accessories Guide
More informationHeat Pump Air Conditioning Systems
Heat Pump Air Conditioning Systems Create your own Utopia. In a climate as diverse as ours air conditioning your premises can make a huge difference to the comfort of your staff, and your customers too.
More informationSiUS091601E Inverter Pair Wall Mounted Type FTX-N Series Floor Standing Type FVXS-N Series [Applied Models] Inverter Pair : Heat Pump
Service Manual Inverter Pair Wall Mounted Type FTX-N Series Floor Standing Type FVXS-N Series [Applied Models] Inverter Pair : Heat Pump Inverter Pair Wall Mounted Type FTX-N Series Floor Standing Type
More informationDESIGN & TECHNICAL MANUAL
AIR CONDITIONER Wall Mounted type DESIGN & TECHNICAL MANUAL INDOOR AS A09LEC AS A12LEC OUTDOOR AO R09LECN AO R12LECN 1.INDOOR UNIT : AS A09LEC AS A12LEC DTR_AS047E_01 2010.10.05 1. INDOOR UNIT CONTENTS
More informationAIR-TO-WATER HEAT PUMP (50Hz/R410A) 5BPU0-03A(Replace:5BPU0-02A)
AIR-TO-WATER HEAT PUMP (50Hz/R410A) 5BPU0-03A(Replace:5BPU0-02A) AIR-TO-WATER HEAT PUMP (50Hz/R410A) 5BPU0-03A(Replace:5BPU0-02A) CONTENTS Part 1. Introduction Part 2. Indoor Unit(Hydro kit) Part 3. Outdoor
More informationSiUS RXYQ72, 96, 144, 168, 192MTJU R-410A Heat Pump 60Hz RXYQ72MTJU RXYQ96MTJU RXYQ144MTJU RXYQ168MTJU RXYQ192MTJU
SiUS39-601 RXYQ72, 96, 144, 168, 192MTJU R-410A Heat Pump 60Hz RXYQ72MTJU RXYQ96MTJU RXYQ144MTJU RXYQ168MTJU RXYQ192MTJU R-410A Heat Pump 60Hz 1. Introduction... vi 1.1 Safety Cautions...vi 1.2 PREFACE...
More informationU-Match Systems 12,000 to 60,000 BTU/Hr 60 Hz
U-Match Systems 12,000 to 60,000 BTU/Hr 60 Hz A sense of comfort thro A single solution for three different product applications Concealed Indoor Unit Outdoor Unit (showing 12,000-18,000 BTU/hr) Trane
More informationMulti Air Conditioner Indoor Unit SVC MANUAL(General)
Internal Use Only http://biz.lgservice.com Multi Air Conditioner Indoor Unit SVC MANUAL(General) CAUTION Before Servicing the unit, read the safety precautions in General SVC manual. Only for authorized
More informationSingle "A" Air Conditioner SVC MANUAL(General)
Internal Use Only http://biz.lgservice.com Single "A" Air Conditioner SVC MANUAL(General) MODEL : Single "A"-Inverter Type CAUTION Before Servicing the unit, read the safety precautions in General SVC
More informationDESIGN & TECHNICAL MANUAL
AIR CONDITIONER Wall Mounted type DESIGN & TECHNICAL MANUAL INDOOR ASU9RL2 ASU12RL2 OUTDOOR AOU9RL2 AOU12RL2 1.INDOOR UNIT : ASU9RL2 ASU12RL2 DTR_AS072E_01 2012.11.02 1. INDOOR UNIT CONTENTS 1. FEATURE...
More informationSingle "A" Air Conditioner SVC MANUAL(General)
Internal Use Only http://biz.lgservice.com Single "A" Air Conditioner SVC MANUAL(General) MODEL : Single "A"-Inverter Type CAUTION Before Servicing the unit, read the safety precautions in General SVC
More informationDESIGN & TECHNICAL MANUAL
AIR CONDITIONER Wall mounted type DESIGN & TECHNICAL MANUAL INDOOR ASYG07KGTA ASYG09KGTA ASYG12KGTA ASYG14KGTA OUTDOOR AOYG07KGCA AOYG09KGCA AOYG12KGCA AOYG14KGCA DR_AS049EF_02 2017.10.11 Notices: Product
More informationIndoor Dimensions units Ducted Type LG Electronics 6.2 Outdoor units Ducted Type CALOR SRL LG Electronics
LG Multi Split system is an advanced air conditioning system of superior quality that has the ability to operate at different temperatures and fan speeds in individual rooms. The multi split system can
More informationSiBE041010EA. Service Manual. Inverter Pair Wall Mounted Type J-Series. [Applied Models] Inverter Pair : Heat Pump
Service Manual Inverter Pair Wall Mounted Type J-Series [Applied Models] Inverter Pair : Heat Pump Inverter Pair Wall Mounted Type J-Series Heat Pump Indoor Unit FTX20JV1B FTX25JV1B FTX35JV1B FTX20J2V1B
More informationMONO & MULTI SPLIT AIR CONDITIONERS
MONO & MULTI SPLIT AIR CONDITIONERS SINGLE SPLIT DCI INVERTER TECHNOLOGY Low Consumption Low Noise Level Precise temperature set ENERGY CLASS IR REMOTE Standby 0,5W 3 Sleep Curve Comfortable Cold Air Prevention
More informationService Manual. Inverter Pair Floor / Ceiling Suspended Dual Type BA-Series. SiBE05-722_C
Service Manual Inverter Pair Floor / Ceiling Suspended Dual Type BA-Series [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump Inverter Pair Floor / Ceiling Suspended Dual Type BA-Series
More informationDuctless Split Systems. J Series. The Next Generation of Ductless Split Systems
Ductless Split Systems J Series The Next Generation of Ductless Split Systems Advanced technology delivering quiet, energy efficient comfort solutions THE EXPERTS IN ROOM AIR CONDITIONING The Next Generation
More informationSUBMITTAL M4MLW1809A-SUB-1A. Specifications 18 SERIES. Single Zone Mini-Split Inverter System M4MLW1809A1N0A M4TLS1809A11NA TAG:
M4MLW1809A-SUB-1A TAG: 18 SERIES SUBMITTAL Specifications Single Zone Mini-Split Inverter System M4MLW1809A1N0A M4TLS1809A11NA MODEL - Heat Pump Only RATED Volts/PH Frequency (Hz) Rated Cooling / Heating
More informationDuctless Split Systems. J Series. The Next Generation of Ductless Split Systems
Ductless Split Systems J Series The Next Generation of Ductless Split Systems Advanced technology delivering quiet, energy efficient comfort solutions THE EXPERTS IN ROOM AIR CONDITIONING The Next Generation
More informationFloor Standing. FV Series PLXSPH1502. COOLING ONLY [60Hz]
PLXSPH1502 Floor Standing FV Series Dealer Lot 60334, Persiaran Bukit Rahman Putra 3, Taman Perindustrian Bukit Rahman Putra, 47000 Sungai Buloh, Selangor Darul Ehsan, Malaysia http://www.daikin.com/global_ac/
More informationSiBE04-808_C. Service Manual. Inverter Pair Wall Mounted Type G-Series. [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump
Service Manual Inverter Pair Wall Mounted Type G-Series [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump Inverter Pair Wall Mounted Type G-Series Cooling Only Indoor Unit FTXS20G2V1B
More informationSiUS181631EA. Service Manual. Multi-Split Type Air Conditioners RMXS-L Series. [Applied Models] Inverter Multi : Heat Pump
Service Manual Multi-Split Type Air Conditioners RMXS-L Series [Applied Models] Inverter Multi : Heat Pump Multi-Split Type Air Conditioners RMXS-L Series Heat Pump Outdoor Unit RMXS48LVJU Branch Provider
More informationDuctless Split Systems Ceiling Cassette Heat Pumps
Ductless Split Systems Ceiling Cassette Heat Pumps PURCHASER P.O. # DATE PROJECT LOCATION ENGINEER ARCHITECT SUBMITTED BY FOR APPROVAL FOR REFERENCE ITEM PLAN DESIGNATION QUANTITY COOLING BTU/H VOLTAGE
More informationPackaged Air Conditioners Duct Connection Type [50Hz] FDMG-AV1(S) Series Cooling Only
ED 40-437 Packaged Air Conditioners Duct Connection Type [50Hz] (Middle Static Pressure Application) FDMG-AV1(S) Series Cooling Only ED40-437 Duct Connection Type Middle Static Pressure Application [50Hz]
More informationEHH SERIES DRAW THROUGH FAN COILS CFM
EHH SERIES DRAW THROUGH FAN COILS 400-5000 CFM TABLE OF CONTENTS TABLE OF CONTENTS 2 INTRODUCTION 3 GUIDE SPECIFICATIONS 4 UNIT OVERVIEW 6 TECHNICAL DATA 8 DIMENSIONS 10 COMPUTER SELECTION 11 GEMCOOL PROFILE
More informationJust feel well. 2017/2018 Air conditioning
1947-20 17 2017/2018 Air conditioning Unique solutions 40 Unique and advanced design for vertical or horizontal installation VERTICAL INSTALLATION q Vertical installation with compact dimensions, only
More informationductless mini-splits light commercial and multi-zone systems product catalog ALEGRIA ALEGRIA
ALEGRIA PLATINUM SERIES ALEGRIA GOLD SERIES ductless mini-splits light commercial and multi-zone systems 2017 product catalog comfortstar 2 ductless mini-splits Series to choose from With over 50 years
More informationSiBE39-402A. Service Manual. R-410A Heat Pump 50Hz
SiBE3-402A Service Manual R-410A Heat Pump 50Hz SiBE3-402A R410A Heat Pump 50Hz 1. Introduction... vi 1.1 Safety Cautions... vi Part 1 General Information... 1 1. Model Names of Indoor/Outdoor Units...2
More informationDuctless Split Systems Wall-mounted, Multizone Heat Pump
Ductless Split Systems Wall-mounted, Multizone Heat Pump PURCHASER P.O. # DATE PROJECT LOCATION ENGINEER ARCHITECT SUBMITTED BY FOR APPROVAL FOR REFERENCE ITEM PLAN DESIGNATION QUANTITY COOLING BTU/H VOLTAGE
More informationAir Conditioning. Technical Data. Concealed ceiling unit with high ESP EEDEN FXMQ-MB
Air Conditioning Technical Data Concealed ceiling unit with high ESP EEDEN15-204 FXMQ-MB Indoor Unit FXMQ-MB TABLE OF CONTENTS FXMQ-MB 1 Features.............................................................
More informationmini-cassette W MULTI SPLIT R410A & VRF SERIES AUTO MODEL MDH13HLS MDH13HLS
mini-cassette 18.000 24.000 AUTO MODEL MDH13HLS MDH13HLS Cooling capacity W 3852 3852 Cooling capacity BTU/h 13135 13135 The best Heating technology capacity W in air conditioning 4205 4205 Heating capacity
More informationUp to SEER 26.1 Wall Mount Heat Pump
Up to SEER 26.1 Wall Mount Heat Pump EXPERTISE AND INNOVATION Daikin s Quaternity system incorporates technological innovations that deliver features and benefits superior to traditional mini split systems.
More informationDuctless Split Systems Concealed Duct Heat Pumps
Ductless Split Systems Concealed Duct Heat Pumps PURCHASER P.O. # DATE PROJECT LOCATION ENGINEER ARCHITECT SUBMITTED BY FOR APPROVAL FOR REFERENCE ITEM PLAN DESIGNATION QUANTITY COOLING BTU/H VOLTAGE FRIEDRICH
More information3. INDOOR UNIT OPERATION
3. INDOOR UNIT OPERATION INDOOR UNIT OPERATION 3- FAN CONTROL 3-- Fan Speed Setting Fan speed setting Press the FAN CONTROL button to set the fan speed. AUTO HIGH MED LOW 3-- "AUTO" Position. COOL OPERATION
More informationTECHNICAL & SERVICE MANUAL
SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS TECHNICAL & SERVICE MANUAL October 202 No. OCH446 REVISED EDITION-E HFC utilized R40A [Model name] PUMY-P00VHMB PUMY-P25VHMB PUMY-P40VHMB PUMY-P00VHMB-BS
More informationPMFY-P-VBM-E. Ceiling cassette (1-way flow type) R410A Data G8 1. SPECIFICATIONS EXTERNAL DIMENSIONS CENTER OF GRAVITY 1-100
Ceiling cassette (-way flow type) RA Data G8 -P-VBM-E. SPECIFICATIONS - 98. EXTERNAL DIMENSIONS - 99 3. CENTER OF GRAVITY -. ELECTRICAL WIRING DIAGRAMS -. SOUND LEVELS -. Sound levels -. NC curve 6. TEMPERATURE/AIRFLOW
More informationProduct Brochure Smart Power. Low Profile Ducted
Product Brochure 2017 Smart Power Low Profile Ducted 2017 Brand Story The Internet era is a diverse and unconventional time, where one size fits all products and solutions simply aren t enough. Customers
More informationAir Conditioner CONTENTS
ORDER NO. MAC0509068C2 Air Conditioner CS-F24DD1E5 CU-B24DBE5 CS-F28DD1E5 CU-B28DBE5 CS-F28DD1E5 CU-B28DBE8 CS-F34DD1E5 CU-B34DBE5 CS-F34DD1E5 CU-B34DBE8 CS-F43DD1E5 CU-B43DBE8 CS-F50DD1E5 CU-B50DBE8 CONTENTS
More informationPCXSPH1732A. Warning. Head office: Umeda Center Bldg., , Nakazaki-Nishi, Kita-ku, Osaka, Japan.
Warning Daikin products are manufactured for export to numerous countries throughout the world. Prior to purchase, please confirm with your local authorised importer, distributor and/or retailer whether
More informationSUBMITTAL M4MCW1509A-SUB-1B. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA TAG:
M4MCW1509A-SUB-1B TAG: 15 SERIES SUBMITTAL Specifications Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA MODEL - Cooling Only RATED Volts/PH Frequency (Hz) Rated Cooling Capacity
More informationDC Inverter Multi-split System Technical Manual - 50Hz/R410a
DC Inverter Multi-split System Technical Manual - 50Hz/R410a A/1/LCAC/2/TM/2.0 General Information Contents Part 1. General Information... 4 1. Features... 4 2. Nomenclature... 6 3. Products Line-up...
More informationDESIGN & TECHNICAL MANUAL
AIR CONDITIONER Wall mounted type DESIGN & TECHNICAL MANUAL INDOOR ASYG18KLCA ASYG24KLCA OUTDOOR AOYG18KLTA AOYG24KLTA DR_AS069EF_01 2018.03.16 Notices: Product specifications and design are subject to
More informationKühl J Series DUCTLESS ROOM AIR CONDITIONERS THE EXPERTS IN ROOM AIR CONDITIONING. Wall-mounted Ceiling Cassette The Insider Concealed Ducted
Kühl J Series DUCTLESS ROOM AIR CONDITIONERS SPLIT SYSTEMS Wall-mounted Ceiling Cassette The Insider Concealed Ducted THE EXPERTS IN ROOM AIR CONDITIONING THE NEXT GENERATION OF DUCTLESS SPLIT SYSTEMS
More informationModels: ACC 75D/DR ACC 100D/DR. ACC - D (Draft) Ceiling Concealed Split Systems
Models: ACC 75D/DR ACC 100D/DR ACC - D2-2007 (Draft) Ceiling Concealed Split Systems CONTENTS 1. NOMENECLATURE... 2 2. FEATURES... 4 3. PRODUCT LINE UP... 5 4. SPECIFICATIONS... 8 5. OPERATING RANGE...
More informationPAC (FLOOR STANDING) 2016 Samsung
2016 Samsung PAC (FLOOR STANDING) SAMSUNG ELECTRONICS., LTD. Head Office : Suwon, Korea 416, Maetan-3Dong, Paldal-Gu, Suwon City Kyungki-Do, Korea 442-742 For more Information please visit www.samsung.com
More informationDESIGN & TECHNICAL MANUAL
AIR CONDITIONER Duct type DESIGN & TECHNICAL MANUAL INDOOR ARU9RLF ARU12RLF ARU18RLF OUTDOOR AOU9RLFC AOU12RLFC AOU18RLFC 1. INDOOR UNIT : ARU9RLF ARU12RLF ARU18RLF DTR_AR059E_05 2015.06.01 1. INDOOR UNIT
More informationSiUS04-924_A. Service Manual. Inverter Pair Wall Mounted Type H-Series. [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump
Service Manual Inverter Pair Wall Mounted Type H-Series [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump Inverter Pair Wall Mounted Type H-Series Cooling Only Indoor Unit FTXS30HVJU
More informationSUBMITTAL M4MHW1509A-SUB-1B. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MHW1509A1N0A M4THS1509A11NA TAG:
M4MHW1509A-SUB-1B TAG: 15 SERIES SUBMITTAL Specifications Single Zone Mini-Split Inverter System M4MHW1509A1N0A M4THS1509A11NA 2017 Ingersoll Rand All Rights Reserved MODEL - Heat Pump Only RATED Volts/PH
More informationDucted inverter reverse cycle air conditioning
Ducted inverter reverse cycle air conditioning What is ducted inverter reverse cycle air conditioning? Ducted inverter reverse cycle air conditioning is an ideal solution for whole-of-home or office cooling
More informationSingle-Zone Four-Way Ceiling-Cassette System Engineering Manual
Single-Zone Four-Way Ceiling-Cassette System Engineering Manual Single-Zone Four-Way Ceiling Cassette Heat Pump Systems 1.5 to 3.5 Tons LC187HV (18,000 Btu/h) LC247HV (24,000 Btu/h) LC367HV (36,000 Btu/h)
More informationMULTI. MPS Variable Multi System(50Hz, R22) Tropical, Free Joint LM F4. P/No.: 3828A20428P. Replaces: LM F3
MULTI MPS Variable Multi System(50Hz, R22) Tropical, Free Joint Approvals: ST IR M EN ISO 9001 F S O E R E D 97 9 001 A8 For continual product development, LG reserves the right to change specifications
More informationLG Electronics AE Company, Commercial Air Conditioning
www.lgeaircon.com New concept Ecofriendly Highefficiency Heating solution Total heating & Hot water Solution for MULTI V LG Electronics AE Company, Commercial Air Conditioning 2 Yeouidodong, Yeongdeungpogu,
More informationInverter Single (50Hz/R410A) 5RMA2-01B(5RMA2-01A)
Inverter Single (50Hz/R410A) 5RMA2-01B(5RMA2-01A) Inverter Single-50Hz(R410A) Contents Page 1. Models line up...4 2. Nomenclature...6 3. Features & Benefits...8 4. Specifications...19 5. Dimensions...31
More informationA single answer for multiple zones.
FJM - Free Joint Multi A single answer for multiple zones. More comfort with less. This powerful unit supports up to five indoor units for multi-zone control with one outdoor unit. It s also available
More information2 &3-4 Head Multi System
2 &3-4 Head Multi System INVERTER 2 &3-4 ROOM Multi System The Fujitsu Inverter Multi System has been designed with flexibility in mind. With the introduction of indoor units in a range of capacities and
More information