PLEASE DO NOT DISCARD THE ATTACHED DOCUMENT IS NECESSARY FOR THE INSTALLATION OF YOUR GREASE TRAP.
|
|
- Chrystal Chambers
- 5 years ago
- Views:
Transcription
1 PLEASE DO NOT DISCARD THE ATTACHED DOCUMENT IS NECESSARY FOR THE INSTALLATION OF YOUR GREASE TRAP.
2 GI SERIES GREASE TRAP INSTALLATION GUIDE Overview Atlantic Metalworks GI series grease traps are designed to meet the needs of large and small commercial kitchens. Grease capacities range from 8-100lbs and the carbon steel construction makes the grease traps extremely durable. All of our GI series grease traps are backed by a one year warranty on material and workmanship, and are PDI (Plumbing and Drainage Institute) certified, guaranteeing that the grease traps will match or surpass industry standards.
3 Pre-Installation Checklist A few things to consider prior to installation: Make sure the location where the grease trap will be installed is clean, flat, and solid. Do not install the grease trap backwards. Look for markings on the grease trap for designations of the inlet and outlet side. Image 1 - location of inlet marking Open the grease trap and check its internal components. Contact us immediately if the baffle or flow control device is missing. See the footer for our contact information and hours of operation. A - flow control device B - installation guide C - baffle B A C Please note that the picture to the left shows pre-drilled holes for four bolts - 2 per stabilization bar. This applies only to the GI-50 and larger units. Smaller units will only have one pre-drilled hole for one stabilization bar. Image 2 - internal components 3
4 We recommend that you hold all clearances around and above the grease trap at a minimum of 12 inches for maintenance and cleaning purposes. This allows for ease of access during maintenance. The placement of your grease trap should allow the cover to be visible and easily removable for cleaning, and clearances should be such that the internal baffling can be serviced. With the cover removed, all wetted surfaces should be visible. This is necessary not only for access to clean the grease trap, but also to easily inspect the interior for potential problems such as damaged baffles and blocked air relief bypasses See image 3 below for an example of a set-up with proper clearances. Image 3 - proper setup with recommended clearances 4
5 Installation Instructions Diagram 1 - Installation Layout Sink Vented Waste Air-Intake Vent Grease Trap Vented Flow Control Required Flow Control Device IMPORTANT NOTE: The grease trap was tested and rated with the use of a flow control device. This device has been included with the grease trap. Any attempt to use the grease trap without the flow control device will compromise the functionality of the grease trap, which means clogged drains and fines from regulatory bodies. 5
6 Installation Steps 1. You will need a minimum of 4 no-hub couplers to properly install your grease trap. One no hub-coupler for venting and three for the rest of the plumbing directly connected to the grease trap. See the Dimensions and Specifications sheet on page 12 for the required sizes of the no-hub couplers. Install the no-hub coupler on the grease trap inlet side as seen in image 4 below. Image 4 connecting the no-hub coupler 2. After removing the flow control device from the grease trap, locate the grease trap inlet and outlet positions. Position the grease trap so that the inlet position is closest to the equipment you are hooking up to. For optimal performance, the grease trap should be installed as close to the sink as possible while still allowing for the proper clearances to be maintained. See image 3 on page three. 6
7 WARNING DO NOT INSTALL THE GREASE TRAP BACKWARDS. Verify the inlet and outlet positions. Ensure that the flow control is connected to the baffle side of the grease trap as shown in image 5 below. Baffle Image 5 top view of flow control on the baffle side of the grease trap WARNING DO NOT INSTALL THE FLOW CONTROL DEVICE BACK- WARDS. Notice from image 6 below that the flow control device should be installed on the inlet side of the grease trap. 7
8 3. Install the flow control device between the sink and the inlet side of the grease trap as illustrated in image 6 below. See image 3 on page three for additional reference. Image 6 flow control on the baffle side of the grease trap Make sure the flow control device itself is installed facing the right direction. The flow control device has its own inlet and outlet side. The inlet side should be installed facing the equipment/sink and the outlet side facing the inlet of the grease trap. See the image below for the proper installation orientation of the flow control device. To the sink/inlet Note that the open slot in the device is on the grease trap side of the device. Flow control device outlet to the grease trap inlet Image 7 proper orientation of flow control device 8
9 4. Once the flow control device is connected to the grease trap, install an appropriately sized no-hub coupler to the vent of the flow control device as shown in image 8 below. See the Dimensions and Specifications sheet for the required coupler sizes per application. Image 8 flow control vent connection 5. The flow control device is now ready to be connected to your sink. The final set up should look like image 9 below. Image 9 final set-up of flow control device 9
10 6. Vent the flow control device/tee as illustrated in Diagram 1 to ensure the optimal performance of your grease trap. The flow control device must be properly vented to permit air to properly mix with the fluid entering the grease trap. Air facilitates FOG separation and is necessary for proper operation. Without the vented flow control device, wastewater flows will exceed the rated capacity of your grease trap, causing incoming wastewater to pass through your grease trap before the separation of FOGs and food solids. This will result in the buildup of grease downstream, which defeats the purpose of your grease trap. 7. Install a no-hub coupler and make the plumbing connection to the outlet side. See image 10 below. WARNING: DO NOT INSTALL THE FLOW CONTROL DEVICE TO THE OUTLET SIDE. Image 10 connection to the outlet side 10
11 8. Set the lid back in place and secure the lid retaining bolts. Make sure the rubber gasket is clean to ensure a good seal. Image 11 final seal 9. Check the integrity of all connections and the lid gasket by filling the grease trap with water from the equipment connected to the grease trap. 11
12 Maintenance Due to the hazardous nature of FOGs, Personal Protective Equipment (PPE) must be worn at all times during any maintenance performed on the grease trap. TIP: One week after installation, check the grease level inside the grease trap. The results after the first week of usage can be used to determine an appropriate cleaning schedule. Minimize the number of solids that enter the grease trap. The more solids there are, the more cleaning is necessary. Consider installing a solids trap if there is no way to minimize solids from entering the grease trap. 1. To clean, remove lid and baffle, then extract or skim grease into an empty container. As you clean, be sure to focus on the inlet, outlet and air relief ports. It is important to keep these clear of obstructions. 2. Place the cleaned baffle and lid back in place. Position the cleaned baffle back into its slot and secure the lid with its retaining bolts. 3. Do not forget to check the flow control device for clogs. The flow control device is also a serviceable component. Make sure to use nohub couplers to connect the device, to facilitate ease of access for inspection and cleaning as needed. 4. See local codes for safety regulations and contact a FOG collection and disposal company for region-specific guidelines for proper installation and grease disposal. You are responsible to keep the grease trap compliant with local, state, and federal regulations. Servicing and Troubleshooting The grease trap needs to be serviced regularly. You can choose to service it yourself or contact a professional grease trap servicing and maintenance company. If the grease trap is clogged, check the inlet side for any obstructions at the large flow reducing baffle. Your grease trap may need servicing if your sink drains slower than usual. Warranty Statement Atlantic Metalworks warranty covers defects in material and/or workmanship for a period of one year from the date of purchase. 12
13 Dimensions and Specifications Model GI-8 GI-14 GI-20 GI-30 GI-40 GI-50 GI-70 GI-100 Grease Capacity (lbs.) Flow Rate (GPM) Width (in) - (A) /4 24 1/4 27 3/8 30 1/4 32 1/4 Depth (in) - (B) 10 1/4 13 3/8 14 3/8 15 3/4 15 3/4 18 3/8 17 7/8 22 Height (in) - (C) 11 1/4 12 1/8 12 1/8 13 7/ /2 19 3/8 21 1/2 Inlet/Outlet Height (in) - (D) 7 1/4 8 1/4 8 1/8 10 3/8 11 1/ /2 16 1/2 Nominal Pipe Size (in) - (E) Vent Size (in) 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 1 1/2 Weight (lbs.)
14 B Outlet E C A A Cover not shown B TOP VIEW TOP VIEW Note: Bolt configuration applies to GI-50, 70 & 100 Note: Bolt configuration applies to GI-40, 30, 20, 14 and 8 Air Relief Baffle Inlet D CLEANING AND MAINTENANCE DO NOT DISPOSE OF FOG IN DRAINAGE SYSTEM REMOVE COVER REMOVE GREASE (FOG) FROM TOP OF SEPARATION CHAMBER REMOVE ANY SOLIDS FROM BOTTOM OF CHAMBER INSPECT INTERCEPTOR AND CLEAN IF NECESSARY MAKE CERTAIN ALL PASSAGES INCLUDING AIR RELIEF ARE CLEAR OF OBSTRUCTIONS CHECK INTEGRITY OF BAFFLE AND MAKE SURE IT IS IN PLACE CHECK COVER GASKET FOR ANY DAMAGE, REPLACE IF NECESSARY REPLACE COVER TIGHTEN COVER HOLD DOWN BOLT(S) AND SCREWS * A, B, C, D & E DEFINED ON DIMENSIONS AND SPECIFICATIONS SHEET SIDE VIEW 14
15 GREASE TRAP CLEANING LOG Establishment Name: Address: City: State: Zip Code: Phone Number: ( ) - Be sure to check all local and state regulations before maintaining your AMW Grease Trap. This Log must be kept on file for a minimum of three (3) years. Date: Cleaned By: Grease Removed (Inch): Comments: 4603 Poplar Level Rd., Louisville, KY Phone:
OPERATION, INSTALLATION AND MAINTENANCE INSTRUCTIONS SERIES INTERCEPTORS
OPERATION, INSTALLATION AND MAINTENANCE INSTRUCTIONS 5400-5500 SERIES INTERCEPTORS 5401 75 4NH 5500 50 3IPS INSTALLATION Place the Wade interceptor downstream of the drain which will supply the oil laden
More informationInterSeptor Centrifugal Separators Operating & Maintenance Manual
General Information: This manual was prepared to assist in the installation, operation, and maintenance of PEP ICS centrifugal separator systems. For immediate response to questions not covered in this
More informationThere are a few factors critical in the operation of a grease interceptor, which are: Design, Sizing, Proper installation and maintenance.
TEL: 773-341-3030 FAX: 773-341-3046 TOLL FREE: 1-800-465-2736 WEBSITE: www.mifab.com Grease Interceptors Description of Operation: There are a few factors critical in the operation of a grease interceptor,
More informationCombined FOG intercept and treatment system
BIOLOGICAL DRAIN MAINTENANCE SYSTEM Combined FOG intercept and treatment system designed to retain and breakdown Fats, Oils and Grease (FOG) to prevent them from entering the drainage system. The system
More informationSUPPLEMENTARY INSTRUCTIONS
www.burcam.com 2190 Dagenais Blvd.West TEL: 514.337.4415 LAVAL (QUEBEC) FAX: 514.337.4029 CANADA H7L 5X9 info@burcam.com SUPPLEMENTARY INSTRUCTIONS MODEL 450475 Dear consumer, We thank and congratulate
More informationINSTALLATION INSTRUCTIONS REVISED: JUNE 2014
INSTALLATION INSTRUCTIONS REVISED: JUNE 2014 INDEX: UNPACKING INSTRUCTIONS page 2 INSTALLATION INSTRUCTIONS page 3 CONNECTIONS page 6 Equipment must be installed in compliance with all applicable local
More informationGrease Control Device Maintenance Recordkeeping
Grease Control Device Maintenance Recordkeeping All food service establishments are required to keep maintenance records for their grease traps, interceptors, and mechanical grease control devices for
More informationSAFETY PRECAUTIONS. 2) Before operating machine: - Make sure all safety devices are in place and operate properly.
TABLE OF CONTENTS Machine Components Safety Precautions Machine Set Up Machine Operation Machine Maintenance & Storage Troubleshooting Technical Specifications Parts Lists Wiring Diagram 1 2 3 3-4 5 6
More informationProhibitions on using
Prohibitions on using Chemicals, Enzymes, or Bacteria in Grease Traps and Interceptors CHEMICALS ENZYMES BACTERIA Chemicals: the use of chemicals to clean grease traps or interceptors is strictly prohibited
More informationGREASE INTERCEPTORS. Z1192 GREASE RECOVERY APPLIANCE (GRA) INSTALLATION and OPERATION INSTRUCTIONS
Z1192 GREASE RECOVERY APPLIANCE (GRA) INSTALLATION and OPERATION INSTRUCTIONS Note: Zurn Grease Interceptors with grease recognizing sensors are efficient appliances designed to separate grease from water.
More informationAs part of the V.I.P. family, you are entitled to the best protection by one of the most comprehensive warranties in the industry.
CONGRATULATIONS on your purchase of a Viper product, and welcome to the V.I.P. family. We appreciate your business and will do everything in our power to keep you happy with your purchase for many years
More informationOPERATOR'S MANUAL. IMPORTANT: READ OPERATOR'S MANUAL CAREFULLY Please fill out & return your warranty card! DP80405
CARBON SPOT 30 EXTRACTOR OPERATOR'S MANUAL IMPORTANT: READ OPERATOR'S MANUAL CAREFULLY Please fill out & return your warranty card! DP80405 Diamond Products www.diamondproductsus.com Printed in the U.S.A.
More informationI. Best Management Practices (BMPs) to Prevent Blockages in the Sanitary Sewer System
BMP Train kitchen staff and other employees about how they can help ensure BMPs are implemented. Post "No Grease" signs above sinks and on the front of dishwashers. I. Best Management Practices (BMPs)
More informationSERVING CANADA INSTALLATION INSTRUCTIONS REVISED: AUGUST 2014
SERVING CANADA INSTALLATION INSTRUCTIONS REVISED: AUGUST 2014 INDEX: UNPACKING INSTRUCTIONS page 2 INSTALLATION INSTRUCTIONS page 3 CONNECTIONS page 6 Equipment must be installed in compliance with all
More informationProduct Overview. About Us. Grease Traps Generic Types. Extended Capacity Hydromechanical Grease Traps
About Us Product Overview Extended Capacity Hydromechanical Grease Traps Endura XL 75 Models DGT75 598L Light Trafficable Lid DGT75P 598L Pedestrian Lid Industry leading separation efficiency based on
More informationWHOLE HOUSE FILTER &
INSTALLATION, OPERATION AND MAINTENANCE MANUAL Warning Please read carefully before proceeding with installation. Your failure to follow any attached instructions or operating parameters may lead to the
More informationAir Storm Fans. Air Storm 54 Fiberglass Fan Installation and Operation Manual
Air Storm 54 Fiberglass Fan Installation and Operation Manual Table of Contents GrowerSELECT General Page... 3 Safety... 4 Warning Labels... 4 Installation... 5 Operation Safety... 5 Maintenance Safety...
More information2006 Thermaco, Inc. All rights reserved Patented/Patents Pending Specifications subject to change without notice
One to Three Compartment Sink When planning a multiple fixture discharge into a single Big Dipper, establish the size unit required by following the method outlined in the sizing section of this manual.
More informationINSTALLATION INSTRUCTIONS (CANADA)
INSTALLATION INSTRUCTIONS (CANADA) MODEL GOS40 (OTHER MODELS ARE SIMILAR) INDEX: UNPACKING INSTRUCTIONS page 2 INSTALLATION INSTRUCTIONS page 3 Regular Installation Design but not limited to page 6 CONNECTIONS
More informationProgram Introduction and Policy 1. Frequently Asked Questions 2. Device Maintenance..3. Best Management Practices...4
Carmel Utilities, in accordance with the National Pretreatment Program set forth by E.P.A. regulations (40 CFR 403), has hereby enacted a program for the controlling of Fats, Oils, and Grease discharges
More informationINSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 350 SERIES CIRCULATION HEATERS
INDEECO Circulation Heaters are designed to provide years of trouble free operation if properly installed and maintained. Please read and follow these instructions for installing and maintaining the heater.
More informationHE220, HE260 Humidifier Installation Kit
HE220, HE260 Humidifier Installation Kit WELCOME To the comfortable world of humidified air. When you use your Honeywell humidifier, you notice that your skin is not as dry, and that your scratchy throat
More informationACT Cartridge Dust Collector
IOM-101-1 ACT Cartridge Dust Collector Installation and Operation Manual ACT Dust Collectors CAUTION! Accidents happen, be careful and always follow all local and federal regulations! Fires and explosions
More informationGROWMAX WATER Perfect Water for Plants and Gardens
GROWMAX WATER Perfect Water for Plants and Gardens WATER SYSTEMS FOR HYDROPONICS AND GARDENING GROWMAX 3000 Ultra-Pure Reverse Osmosis Water System Up to 3000 L/D of Pure Water Don't forget to register
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS INDEX: UNPACKING INSTRUCTIONS page 2 INSTALLATION INSTRUCTIONS page 3 CONNECTIONS page 6 UNPACKING INSTRUCTIONS UNPACKING The model you have purchased can operate from left to
More informationOperation & Maintenance Manual MONSOON WET DOWNDRAFT TABLE. Visit our Website for more information on this product.
DIVERSITECH Operation & Maintenance Manual MONSOON WET DOWNDRAFT TABLE MDD-MINI MDD-3X4 MDD-3X6 MDD-3X8 Visit our Website for more information on this product www.diversitech.ca 2500 Alphonse Gariepy,
More informationWhole House Filter Model: WH-LD
INSTALLATION, OPERATION AND MAINTENANCE MANUAL Save manual for future reference Whole House Filter Model: WH-LD! WARNING Please read carefully before proceeding with installation. Your failure to follow
More informationINSTALLATION AND OPERATION MANUAL STEAM COIL BASE CONVECTION STEAMER MODEL SCX-16
INSTALLATION AND OPERATION MANUAL STEAM COIL BASE CONVECTION STEAMER MODEL SCX-16 CROWN FOOD SERVICE EQUIPMENT LTD. 70 OAKDALE ROAD, DOWNSVIEW, (TORONTO), ONTARIO, CANADA, M3N 1V9 TELEPHONE: (416) 746-2358,
More informationMDH Series Air Dryer. User s Guide
MDH Series Air Dryer User s Guide Models covered: MDH1 MDH2 MDH3 MDH4 MDH5 MDH6 1. Welcome & Congratulations Congratulations on your purchase of a new PUREGAS MDH SERIES AIR DRYER! We here at PUREGAS
More informationOPERATION MANUAL VCX-4 Vacuum Coolant Exchanger
OPERATI MANUAL VCX-4 Vacuum Coolant Exchanger MAHLE Aftermarket Inc., Service Solutions 0 Innovation Drive York, PA 740 800-468- www.servicesolutions.mahle.com Manual P/N 05-8446-00 (REV B) TABLE OF CTENTS
More informationKeeping. Fats, Oils, and. Grease. Out of the Sewer
Keeping Fats, Oils, and Grease Out of the Sewer Questions and Answers for Food Service Establishments regarding Fats, Oil, and Grease and Grease Removal Devices City of Paso Robles, Wastewater Division,
More informationModel Series Series
PumpAgents.com - Click here for Pricing/Ordering Model 36800-Series 36900-Series ELECTRIC WATER SYSTEM PUMPS Automatic Multi-Outlet FEATURES Self-Priming Diaphragm Design Allows Dry Running Built-in Discharge
More informationW-150-IS Specifications
W-150-IS Specifications MOTOR/TIMER ENCLOSURE 14 CLEARANCE FROM TOP OF TANK REQUIRED FOR STRAINER BASKET & LID REMOVAL 10.25 2 PIPE / EMPTY INTO COOKING OIL RECYCLING CONTAINER DAILY GC-7 GREASE 8 QUART
More informationZip Econoboil. On wall boiling water. Installation instructions & user manual. Model number: ,
Zip Econoboil On wall boiling water. Model number: 305542, 303542 1 Table of contents Intended Use... 2 Warnings and precautions... 3 Before installation... 5 Technical specification... 6 Installation
More informationLONGONI ENGINEERING SRL
INDEX 1.1 Classification of heat exchanger and components 1.1.2 Type of heat exchanger and components 1.2 Purpose and scope of the manual 1.3 General instruction 1.4 Warning installation 1.5 Notes for
More informationDesign of Precast Concrete Grease Interceptors
Design of Precast Concrete Grease Interceptors Claude Goguen, PE National Precast Concrete Association 2015 Onsite Wastewater Mega Conference Terminology Terminology Terminology Grease is the Word If you
More informationInnovative, Compact Design
Innovative, Compact Design Easy, Effective Compliance What in the world is? The Thermaco, Inc. Trapzilla Supercapacity Grease Trap collects free-floating (non-emulsifed) grease & oils contained in kitchen
More informationAUTOTROL 363TC AUTOMATIC FILTER VALVE SERVICE MANUAL
AUTOTROL 363TC AUTOMATIC FILTER VALVE SERVICE MANUAL 2013 Pentair Residential Filtration, LLC www.pentairaqua.com/pro TABLE OF CONTENTS MANUAL OVERVIEW... 2 SAFETY INFORMATION... 2 TYPICAL TOOLS AND FITTINGS
More informationElectrical cable Water supply tube Fittings for tube Coupler Teflon tape. Hole saw min. 2½" bit
Installation Parts and Tools Parts not Provided Electrical cable Water supply tube Fittings for tube Coupler Teflon tape Air gap Wire nuts for 6-gauge wiring Hose clamp ⅞" UL approved strain relief Electrical
More informationINSTALLATION ADJUSTMENT SERVICE
Bulletin XL-670 July 201 INSTALLATION ADJUSTMENT SERVICE HIGHLOW THERMOSTATIC WATER MIXING VALVE MODEL XL-670-LF IMPORTANT! Provide valve serial number, (located on valve cover) when ordering parts!! ECO-MIX
More informationStandard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual
Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual Standard Evaporative Cooler CELDEK Evaporative Cooler RECEIVING AND INSPECTION Upon receiving unit, check
More informationTABLE OF CONTENTS. Site preparation 2 Placement. 2 Chimney and stove pipe connections. 2
TABLE OF CONTENTS SECTION TITLE PAGE 1. SITE PREPARATION AND INSTALLATION Site preparation 2 Placement. 2 Chimney and stove pipe connections. 2 Installation. 3 Water supply and return.. 3 Pressure/relief
More informationThanks for shopping with Improvements! Solar Pool Heater XF Item #
Thanks for shopping with Improvements! Solar Pool Heater XF Item # 417912 To order, call 1-800-642-2112 West Chester, OH 45069 If you have any questions regarding this product, call 1-800-642-2112 and
More informationOperation & Maintenance Manual MONSOON WET DOWNDRAFT TABLE
Operation & Maintenance Manual MONSOON WET DOWNDRAFT TABLE MDD-MINI MDD-3X4 MDD-3X6 MDD-3X8 Visit our Website for more information on this product www.diversitech.ca 2500 Alphonse Gariepy, Montreal, Quebec
More informationAir Storm Fans. Air Storm 18 Fiberglass Fan Installation and Operation Manual
Air Storm 18 Fiberglass Fan Installation and Operation Manual Table of Contents GrowerSELECT General Page...3 Safety...4 Warning Labels...4 Installation...5 Operation Safety...5 Maintenance Safety...5
More informationInstallation Manual PS-225 & PS-275
Installation Manual PS-225 & PS-275 Table of Contents Pre-Uncrating Checklist... 1 Verifying System Requirements... 2 Verifying System Direction... 2 Verifying the Electrical Requirements... 2 Removal
More informationInstallation Instructions Built-In Dishwasher
Installation Instructions Built-In Dishwasher If you have questions, call 800.GE.CARES (800.432.2737) or visit our Website at: GEAppliances.com. In Canada, please call 1.800.561.3344 or visit www.geappliances.ca
More informationRESOLUTION Adopted this day of, President of June Lake Public Utility District and its Board of Directors
RESOLUTION 2017-04 RESOLUTION OF THE BOARD OF DIRECTORS OF JUNE LAKE PUBLIC UTILITY DISTRICT ESTABLISHING BEST MANAGEMENT PRACTICES FOR THE DISPOSAL OF FATS OILS AND GREASE Whereas, the June Lake Public
More informationBARRINGTON PRESSURE LITE VITREOUS CHINA SIPHON JET TOILET K-4327
BARRINGTON PRESSURE LITE VITREOUS CHINA SIPHON JET TOILET K-4327 BEFORE YOU BEGIN INSTALLER HAZARD NOTIFICATION WARNING: Risk of injury or water damage. Contents of vessel under pressure can cause severe
More informationUser s Manual. NOTE: This unit does not support ducted operation. For ducted operation, please refer to model WS208L30SS or WS208L36SS
www.windsterhood.com User s Manual UNDER CABINET SERIES WS-208LF30SS WS-208LF36SS NOTE: This unit does not support ducted operation. For ducted operation, please refer to model WS208L30SS or WS208L36SS
More informationVPMmini. Operator's Manual
VPMmini Operator's Manual Whip Mix Corporation 361 Farmington Ave. P.O. Box 17183 Louisville, KY 40217-0183 USA 502-637-1451 800-626-5651 Fax 502-634-4512 www.whipmix.com Features The Whip Mix VPMmini
More informationINSTALLATION & TESTING MANUAL
INSTALLATION & TESTING MANUAL ***CAUTION: Do not lift by yellow enclosure. Reference installation instructions for proper lifting and moving techniques. IMPROPER INSTALLATION MAY RESULT IN RISK OF SCALDING
More informationHE120, HE160 Humidifier Installation Kit
HE120, HE160 Humidifier Installation Kit INSTALLATION INSTRUCTIONS WELCOME To the comfortable world of humidified air. When you use your Honeywell humidifier, you notice that your skin is not as dry, and
More informationFLUID POWER ENERGY, INC. W229 N591 Foster Court Waukesha, WI THERMOSTATIC VALVES. Instruction and Application Guidelines
THERMOSTATIC VALVES Instruction and Application Guidelines Your FPE Thermostatic Valve has been manufactured with extreme care and tested to insure that it had no detectable defects at the time it left
More information17 U.S. gallon portable low profile drain with electric pump
Assembly and operation instructions 17 U.S. gallon portable low profile drain with electric pump Model 3669 Date of issue February 2018 Form number 404513 Version 2 Contents Safety...........................
More informationSpecification Drainage Engineering Guide. Lint Interceptors. Grease, Hair, Solids, and.
Specification Drainage ngineering Guide Grease, Hair, Solids, and Lint Interceptors www.zurn.com GRAS, HAIR, SOLIDS, and LINT INTRCPTORS TABL OF CONTNTS Section Page No. Section Page No. Grease Interceptors..............................
More informationROTISSERIE OVEN PROGRAM GUIDE
ROTISSERIE OVEN PROGRAM GUIDE Goslyn, LP 1904 University Business Dr. #310 McKinney TX 75071 Phone: 888-648- 5040 Fax: 214-618- 3765 WWW.GOSLYN.COM DEC 2013 table of contents general overview 3 Installation
More informationThe Danger signal indicates an immediately hazardous situation which, if not avoided, will result in death or serious injury.
The Danger signal indicates an immediately hazardous situation which, if not avoided, will result in death or serious injury. The Warning signal alerts you to potential hazards or unsafe practices which,
More informationHow To Size A Big Dipper Unit
Sizing Big Dipper Systems In Food Service Operations How To Size A Big Dipper Unit The purpose of this sizing procedure is to give a specifying engineer a simple method for determining the proper size
More informationDRAINMAKER INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST
Manufacturers of... Quality Products since 1866 95 N. Oak St. Kendallville, IN 46755 1-800-345-9422 DRAINMAKER INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST FW0771 0116 Supersedes 0415 MODEL: DATE
More information2 INLET / HIGH HEAD DRAIN PUMP SYSTEMS MODELS , INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST
Your Peace of Mind is Our Top Priority Product information presented here reflects conditions at time of publication. Consult factory regarding discrepancies or inconsistencies. MAIL TO: P.O. BOX 637 Louisville,
More information3/4 HP Model Trimmer Operating Instructions
3/4 HP Model Trimmer Operating Instructions Whip Mix Corporation 361 Farmington Ave. P.O. Box 17183 Louisville, KY 40217-0183 USA 502-637-1451 800-626-5651 Fax 502-634-4512 www.whipmix.com Technical Specifications
More informationSITE REQUIREMENTS & INSTALLATION DSD-201 & SSD-102
Instructions SITE REQUIREMENTS & INSTALLATION DSD-201 & SSD-102 The purpose of this section is to provide the customer with requirements that need to be met before the DSD/SSD can be properly installed.
More informationInstallation Manual PS-200 & PS-201
Installation Manual PS-200 & PS-201 Table of Contents Pre-Uncrating Checklist... 1 Verifying System Requirements... 2 Verifying System Direction... 2 Verifying the Electrical Requirements... 2 Removal
More informationSCHWAN INSTALLATION GUIDE
1 SCHWAN INSTALLATION GUIDE For Schwan SC60 FOR SERVICE OR ASSISTANCE CALL MERQUIP ON 0800 636 0 636. Schwan recommends that a qualified tradesperson installs your Schwan system. 2 INFORMATION AND SAFETY
More informationSAN RAPHAEL PRESSURE LITE VITREOUS CHINA SIPHON JET TOILET
SAN RAPHAEL PRESSURE LITE VITREOUS CHINA SIPHON JET TOILET BEFORE YOU BEGIN HOW TO USE THESE INSTRUCTIONS Please read these instructions carefully to familiarize yourself with the required tools, materials,
More informationINSTALLATION INSTRUCTIONS CARE AND MAINTENANCE
INSTALLATION INSTRUCTIONS CARE AND MAINTENANCE Heritage VorMax Right Height Elongated 2-piece Toilet Model 205AA104 Thank you for selecting American Standard - the benchmark of fine quality for over 100
More informationAC6 & AC8 HORIZONTAL SERIES Sealed Metallic Centrifugal Pumps Installation and Maintenance Instructions
AC6 & AC8 HORIZONTAL SERIES Sealed Metallic Centrifugal Pumps Installation and Maintenance Instructions ASSEMBLY PUMPS WITH MOTORS 1. No assembly required. Unpack the pump and motor and examine for any
More informationModel # VWK-2 INSTRUCTION MANUAL
Model # VWK-2 INSTRUCTION MANUAL Ver. March 2015 ALA Scientific Instruments Inc. 60 Marine Street Farmingdale, NY 11735 Tel. # 631.393.6401 Fax: # 631.393.6407 E-mail: support@alascience.com www.alascience.com
More informationCELDEK Evaporative Cooler Module Installation, Operation, and Maintenance Manual. CELDEK Evaporative Cooler
CELDEK Evaporative Cooler Module Installation, Operation, and Maintenance Manual CELDEK Evaporative Cooler RECEIVING AND INSPECTION Upon receiving unit, check for any interior and exterior damage, and
More informationHE360 Humidifier Installation Kit
HE360 Humidifier Installation Kit INSTALLATION INSTRUCTIONS WELCOME To the comfortable world of humidified air. When you use your Honeywell humidifier, you notice that your skin is not as dry, and that
More informationINSTALLATION INSTRUCTIONS UNDERCOUNTER DISHWASHERS
INSTALLATION INSTRUCTIONS UNDERCOUNTER DISHWASHERS VIKING 111 Front Street Greenwood, Mississippi 38930 USA (662) 455-1200 IMPORTANT - PLEASE READ AND FOLLOW Before beginning - please read these instructions
More informationAir Storm Fans. Air Storm 24 Fiberglass Fan Installation and Operation Manual
Air Storm 24 Fiberglass Fan Installation and Operation Manual Hog Slat Inc. Newton Grove, NC USA May 2015 Table of Contents GrowerSELECT General Page...3 Safety...4 Warning Labels...4 Installation...5
More informationSurna 25-Ton Chiller Operating & Maintenance Manual
www.surna.com 303.993.5271 Surna 25-Ton Chiller Operating & Maintenance Manual Models: 300F3-3. 300F4-3, 300FW-3 Revised: July 2015 Table of Contents Warranty Information 4 Limited Warranty 4 Limitation
More informationDEHUMIDIFIER USER MANUAL 11 PINT FOR MODEL: 3PAD11 COMFORT...BUILT TO LAST
COMFORT...BUILT TO LAST 11 PINT DEHUMIDIFIER USER MANUAL FOR MODEL: 3PAD11 Before using your dehumidifier, please read this manual carefully and keep it for future reference, along with your receipt. CONTENTS
More informationFlow Factor ~
Flow Factor ~ 216-765-4231 The DHC-E series is tested and certified by WQA against NSF/ANSI 372 for lead free compliance. STIEBEL ELTRON Inc. 17 West Street West Hatfield MA 01088 Tel. 413-247-3380 Fax
More informationAUTOTROL 360 MANUAL & 361 SEMI-AUTOMATIC FILTER VALVES SERVICE MANUAL
AUTOTROL 360 MANUAL & 361 SEMI-AUTOMATIC FILTER VALVES SERVICE MANUAL waterpurification.pentair.com TABLE OF CONTENTS MANUAL OVERVIEW... 2 SAFETY INFORMATION... 2 TYPICAL TOOLS AND FITTINGS REQUIRED...
More informationUser Manual AIR HOG. Vacuum Booster REV. 3/20/ Stowe Dr. Poway, CA P: (858) F: (858)
User Manual AIR HOG Model: 7303L Vacuum Booster REV. 3/20/18 13655 Stowe Dr. Poway, CA 92064 P: (858) 679-1191 F: (858) 726-6005 INTRODUCTION Dear Customer: Congratulations on the purchase of your new
More informationUser s Guide REO-MECH. Industrial Rebar Benders & Cutters
User s Guide REO-MECH Industrial Rebar Benders & Cutters WARNING: PLEASE READ THIS MANUAL CAREFULLY BEFORE USING THIS MACHINE Machine is not rated and should not be used for commercial rebar production
More informationInstruction Manual for the Revolutionary Science RS-IF-203 Incufridge
Instruction Manual for the Revolutionary Science RS-IF-203 Incufridge REVOLUTIO NARY SCIENCE Manufacturer of Precision Laboratory Equipment Table of Contents Introduction 2 Recommended Safeguards 3 Operating
More informationGetz Equipment Innovators 450 lb Dual Portable Dry Chemical Fill System
Getz Equipment Innovators 450 lb Dual Portable Dry Chemical Fill System 1 Revised 11/18/10 2320 Lakecrest Drive, Pekin IL 61554 PH. (888) 747-4389 Fax (309) 495-0625 Website: www.getzequipment.com LIMITED
More informationOWNER S MANUAL. Models: AC110, AC125, AC150 made from 2003 through Proudly Made in the USA
OWNER S MANUAL Models: AC110, AC125, AC150 made from 2003 through 2010 Proudly Made in the USA support@aquacomfort.com www.aquacomfort.com/service-and-support/ (888) 475-7443 Manufacturing High Quality,
More informationROTARY TUMBLER LORTONE INSTRUCTIONS AND PARTS LIST. Model 3-1.5B. Model 45C. Model 33B Cyrus Way Mukilteo, WA (425)
ROTARY TUMBLER INSTRUCTIONS AND PARTS LIST Model 3-1.5B Model 45C Model 33B LORTONE 12130 Cyrus Way Mukilteo, WA 98275 (425) 493-1600 SETTING UP YOUR MACHINE For 45C Unit Only (33B & 3-1.5B already assembled)
More informationVSA Series Air Dryer. User s Guide
VSA Series Air Dryer User s Guide Models covered: VSA1 VSA2 VSA3 VSA4 1. Welcome & Congratulations Congratulations on your purchase of a new PUREGAS VSA SERIES AIR DRYER! We here at PUREGAS are very proud
More informationStandard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual
Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual Standard Evaporative Cooler CELDEK Evaporative Cooler RECEIVING AND INSPECTION Upon receiving unit, check
More informationINSTALLATION ADJUSTMENT SERVICE
ASSE 1017 INSTALLATION ADJUSTMENT SERVICE TYPE TM-26, TM-26-LF BULLETIN G-26 January 2014 IMPORTANT! Provide valve serial number (stamped on cover of valve) when ordering parts!! Valve manufactured after
More information11,000 BTU Portable Air Conditioner with dehumidifier & Fan PE4-11R-03 Operating Instructions. Model No. PE4-11R Soleus Air International
11,000 BTU Portable Air Conditioner with dehumidifier & Fan PE4-11R-03 Operating Instructions Model No. PE4-11R-03 2006 Soleus Air International Thank you for choosing a Soleus Air Portable Air Conditioner.
More informationVertical Concealed Fan Coil. FCVC Series MANUAL INSTALLATION, OPERATION, & MAINTENANCE
MANUAL INSTALLATION, OPERATION, & MAINTENANCE Vertical Concealed Fan Coil FCVC Series v100 Issue Date: 12/21/15 2015 Price Industries Limited. All rights reserved. TABLE OF CONTENTS Product Overview Safety
More informationColumbia Boiler Company
EMG Series Boilers Available in Natural Gas & Propane Rev 12012 Columbia Boiler Company PO Box 1070 Pottstown, PA 19464 Tel (610) 473-8457 Fax (610) 367-6800 Website www.columbiaboiler.com Email cbcsales@ptd.net
More informationEco-Safe Digester. Installation Manual For E3 Series Digesters. Version 1.6 Published: Apr. 13, 2017
Eco-Safe Digester Installation Manual For E3 Series Digesters Version 1.6 Published: Apr. 13, 2017 Eco-Safe Digester Installation Manual Table of Contents Preface... iv 1. Document Revision History...
More informationModulAir Air Dryer with External Purge Tank - Changeover from Bendix AD-IS for Peterbilt Installation. Air Dryer Mounting Bracket (Item 1)
Instruction Guide L31259 11/10 ModulAir Air Dryer with External Purge Tank - Changeover from Bendix AD-IS for Peterbilt Installation Air Dryer Mounting Bracket (Item 1) Tank Mounting Bracket (Item 19)
More informationOperator s Manual. Model G14TC-3 Disinfection Soak Station for Transesophageal Ultrasound Probes
Model G14TC-3 Disinfection Soak Station for Transesophageal Ultrasound Probes Operator s Manual CIVCO Medical Solutions 102 First Street South Kalona, IA 52247 USA Tel: 1-800-445-6741 Fax: 1-877-329-2482
More informationAUTOTROL 363 DEMAND AUTOMATIC FILTER VALVE Service Manual
AUTOTROL 363 DEMAND AUTOMATIC FILTER VALVE Service Manual 2014 Pentair Residential Filtration, LLC www.pentairaqua.com/pro TABLE OF CONTENTS MANUAL OVERVIEW... 2 SAFETY INFORMATION... 2 TYPICAL TOOLS AND
More informationCarbon Dioxide Sample-Draw Detector Operator s Manual
35-3001-05-03 Carbon Dioxide Sample-Draw Detector Operator s Manual Part Number: 71-0413 Revision: 0 Released: 8/4/17 www.rkiinstruments.com WARNING Read and understand this instruction manual before operating
More informationModels: FM FM WARNING
Installation Stainless Steel Blowout Urinal Models: 923-8000 923-8001 923-8002FM 923-8003FM Table of Contents Overview...2 Pre-Installation Information...3 Installation Instructions...4-7 Cleaning Instructions...7
More informationINSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE
Bulletin 82 August, 208 INSTALLATION ADJUSTMENT SERVICE HIGHLOW THERMOSTATIC WATER MIXING VALVE SERIES, -LF,, -LF IMPORTANT! Provide valve serial number, (located on valve cover) when ordering parts!!!
More informationInstallation & Operation Instructions For Big Dipper Series Automatic Solids Transfer (AST) Units
Installation & Operation Instructions For Big Dipper 40000 Series Automatic Solids Transfer (AST) Units Models W-250-AST, W-750-AST and W-1250-AST (Including 230 VAC Units) A Big Dipper W-750-AST in a
More informationTECHNICAL DATA. Wet 26a. February 22, 2009
February 22, 2009 Wet 26a 1. DESCRIPTION The Viking Alarm Check Valve serves as a check valve by trapping pressurized water above the clapper and preventing reverse flow from sprinkler piping. The valve
More informationModel LF-310 Air Operated
Microflush Half Gallon Toilets Model LF-310 Air Operated Installation/Service Manual P/N 24156 452 East Hill Road Fax: 707.459.6617 Willits, CA 95490 USA E-mail: info@microphor.com Phone: 707.459.5563
More informationAIC Series Float & Thermostatic Steam Trap Installation and Maintenance Instructions
AIC Series Float & Thermostatic Steam Trap Installation and Maintenance Instructions 138-EN Please read and save these instructions Contents General Safety Information... 3 Product Information...3-5 Product
More information