Level 1. Certificate of Conformity. Australian Certification Services Pty Ltd grants to the WaterMark User: Wallgate Ltd. Trading as Wallgate Ltd
|
|
- Jared Thornton
- 5 years ago
- Views:
Transcription
1 Level 1 Certificate of Conformity Australian Certification Services Pty Ltd grants to the WaterMark User: Trading as the right to use the WaterMark as shown above in conjunction with the Certificate No. on product/s as identified in the WaterMark Schedule and as listed on the WaterMark database which have been shown to comply with the relevant Standard/s and level of certification referred to below. The WaterMark User is granted a licence to use the WaterMark subject to the rules governing the use of the WaterMark. Product Type: Evaluated to: Sanitary Fixtures and Flushing Devices AS :2005 Water Closets (WC) Part 1: Pans AS :1999 Amdt Amdt AS :1999 Amdt Amdt Water closet (WC) pans of 6/3 L capacity or proven equivalent Part 2: Cistern ATS :2004 Technical Specification for plumbing and drainage products Part 020: Flushing valves for water closets and urinals - For use with mains supply ATS :2004 Technical Specification for plumbing and drainage products Part 021: Flushing valves for water closets and urinals For use with break tank supply Issue Date 23 rd August 2016 Paul Greig Initial Issue Date: 29 th April 2013 General Manager Expiry Date: 28 th April 2018 Certificate No.: This certificate remains the property of Australian Certification Services Pty Ltd WaterMark Level 1 certification is a conformity assessment scheme based on ISO Guide 67 (system 5) Page 1 of 6
2 WaterMark Certification Schedule The WaterMark User Certification Standards: AS :2005 Water Closets (WC) Part 1: Pans AS :1999 Amdt Amdt CWC_80 P Trap CWC_100 Solid Surface Material Water Closet Pan Wall Hung P Trap Nominal Flush Volume 6L or 4.5L CWC_150 P Trap CWC_170_L Left P Trap CWC_170_R Right P Trap CWC_88 CWC_155 CWC_177_L Left CWC_177_R Right CWC_250 P Trap Page 2 of 6
3 CWC_255 CWC_270_L CWC_270_R CWC_280 CWC_288 Left P Trap Right P Trap P Trap Page 3 of 6
4 The WaterMark User Certification Standards: AS :1999 Amdt Amdt Water closet (WC) pans of 6/3 L capacity or proven equivalent Part 2: Cistern CISTFV01LH_AUS Plastic Bodied In Wall Dual Flush Electronically Operated Water Closet Cistern Left Hand Inlet Flush Volume 6/3L or 4.5/3L Page 4 of 6
5 The WaterMark User Certification Standards: ATS :2004 Technical Specification for plumbing and drainage products Part 020: Flushing valves for water closets and urinals - For use with mains supply DFKIT01 DN32 Flush Valve Electronically Operated Dual Flush Volume 6/3L or 4.5/3L DFKIT03 DN25 Flush Valve Electronically Operated Dual Flush Volume 6/3L or 4.5/3L DFKIT-CWU-01- HYD DN15 Pneumatically activated Urinal Flush Valve with included Pipe Interrupter Device (PID) Flush Volume 0.3L per Flush for use with Single Stall Wall Hung Urinals Page 5 of 6
6 The WaterMark User Certification Standards: ATS :2004 Technical Specification for plumbing and drainage products Part 021: Flushing valves for water closets and urinals For use with break tank supply FVA007 DN32 Flush Valve Electronically Operated Break Tank Supplied Dual Flush Volume 6/3L or 4.5/3L FVA008 DN25 Flush Valve Electronically Operated Break Tank Supplied Dual Flush Volume 6/3L or 4.5/3L Page 6 of 6
Level 2. Certificate of Conformity. Australian Certification Services Pty Ltd grants to the WaterMark User: Saniflo (Australasia) Pty Ltd
Level 2 Certificate of Conformity Australian Certification Services Pty Ltd grants to the WaterMark User: Saniflo (Australasia) Pty Ltd Trading as Saniflo (Australasia) Pty Ltd the right to use the WaterMark
More informationSTUDENT NOTES Plan, size and layout sanitary pipe work and fixtures
4. SANITARY PLUMBING FULLY VENTED SYSTEM On completion of this module, the student should be able to: Design, install and develop bills of quantities for a fully vented modified system for commercial and
More informationLevel 1. Certificate of Conformity. Australian Certification Services Pty Ltd grants to the WaterMark User: Logi Dezign. Trading as Logi Dezign
Level 1 Certificate of Conformity Australian Certification Services Pty Ltd grants to the WaterMark User: Logi Dezign Trading as Logi Dezign the right to use the WaterMark as shown above in conjunction
More information1 WATERMARK CERTIFICATION SCHEME SCHEDULE OF PRODUCTS This document was adopted 1 August 2017 and replaced the WaterMark Schedule of Specifications
1 WATERMARK CERTIFICATION SCHEME SCHEDULE OF PRODUCTS This document was adopted 1 August 2017 and replaced the WaterMark Schedule of Specifications Product type Application Specification Appliances Bedpan
More informationCertificate of Conformity. Australian Certification Services Pty Ltd grants to the WaterMark User: Aquatica NZ Limited. Trading as Aquatica NZ Limited
Certificate of Conformity Australian Certification Services Pty Ltd grants to the WaterMark User: Aquatica NZ Limited Trading as Aquatica NZ Limited the right to use the WaterMark as shown above in conjunction
More informationWINNER 2. Cod BLOCK. Cod BLOCK AUTOPORTANTE MANUAL SYSTEM PUSH CONTROL PLATES COLOURS. Cod Cod.
Cod. 863302 BLOCK WINNER 2 In-wall flush cistern with dual flush 6/3 or 7.5/4 litres. To obtain a 6/7.5 flush + STOP the push buttons with single flush can be employed. The flush cistern is mounted on
More informationbathroom collection National Customer Service Number the complete range of
bathroom collection the complete range of vitreous china basins, vanity cabinets, toilet suites and mixer taps to complement any home. www.everhard.com.au National Customer Service Number 13 1926 Vitreous
More informationGIANT. Little. Guidelines for Sizing. Pump Company. Sewage Pumps & Systems. Sewage Pumps & Systems
Sewage Pumps & Systems GIANT Little Pump Company Guidelines for Sizing Sewage Pumps & Systems These guidelines cover the steps that need to be taken to accurately select the correct sewage pump and applicable
More informationTrade of Plumbing. Module 2: Domestic Hot and Cold Water Service Unit 11: Sanitary Appliances Phase 2
Trade of Plumbing Module 2: Domestic Hot and Cold Water Service Unit 11: Sanitary Appliances Phase 2 Table of Contents List of Figures... 4 List of Tables... 5 Document Release History... 6 Module 2 Domestic
More information2. Sanitary Plumbing General Installation Requirements
2. Sanitary Plumbing General Installation Requirements On completion of this section, students should be able to: Identify and describe sanitary plumbing installations requirements in accordance with the
More informationWastewater. Guidelines for Sizing mscdirect.com. Call MSC today to learn about the latest LittleGiant products.
Wastewater Guidelines for Sizing Features These guidelines cover the steps which need to be taken to accurately select the correct sewage pump and applicable systems to use in sewage ejectors. Work through
More informationCRAFTSMAN EXAMINATION, NOVEMBER 2009 PLUMBING QUESTION AND ANSWER BOOKLET. Time allowed THREE hours
Affix label with Candidate Code Number here. If no label, enter candidate Number if known No. 9195 CRAFTSMAN EXAMINATION, NOVEMBER 2009 PLUMBING INSTRUCTIONS QUESTION AND ANSWER BOOKLET Time allowed THREE
More informationWATER HAMMER ARRESTORS & MISC. SPECIALTIES
TABLE OF CONTENTS Pictorial Index Water Hammer Arrestors Certification Sizing & Placement Backwater Valves Typical Installations Trap Seal Primers Compliance Pressure & Flow Characteristics Typical Installations
More informationRead Only Document Not For Distribution
Chapter 5 Traps, Cleanouts and Backwater Valves 5.1 SEPARATE TRAPS FOR EACH FIXTURE a. Plumbing fixtures shall be separately trapped by a water seal trap placed as close as possible to the fixture outlet.
More informationREGISTRATION EXAMINATION, NOVEMBER 2014 LICENSED PLUMBER QUESTION AND ANSWER BOOKLET. Time allowed THREE hours
Affix label with Candidate Code Number here. If no label, enter candidate Number if known No. 9192 REGISTRATION EXAMINATION, NOVEMBER 2014 LICENSED PLUMBER INSTRUCTIONS QUESTION AND ANSWER BOOKLET Time
More informationSanitary Drainage Systems
11.1 MATERIALS See Section 3.1. Sanitary Drainage Systems 11.2 BUILDING SEWERS AND BUILDING DRAINS 11.2.1 Sewer or Drain in Filled Ground Chapter 11 Building sewers or building drains that are installed
More informationFresh Water Availability
Water Efficient Products India (WEP I) A Step in the Right Direction Fresh Water Availability Presentation By, Gurmit Singh Arora Indian Plumbing Association (Chairman Mumbai Chapter) Indian Green Building
More informationNovelli Sanitaryware Collection 2010
Novelli Sanitaryware Collection 00 Building Products Pty Ltd Lifestyle Series - Toilet Suites, Basins and Vessels Building Products Pty Ltd Cara Pedestal Basin Armanti Verno Bidet and Cara Back-To-Wall
More informationInstallation Information User Manual
1-5 Anzac Avenue Smeaton Grange NSW 2567 is a division of BioSeptic Pty Ltd - ABN 95 056 461 226 Ph: 02 4629 6633 Fax: 02 4629 6677 Email: sales@sydneywatertanks.com.au Web: www.sydneywatertanks.com.au
More informationRead Only Document Not For Distribution
Chapter 14 Special Requirements For Health Care Facilities 14.1 GENERAL This Chapter applies to special fixtures and systems that occur in health care facilities and to the special plumbing requirements
More informationBOILING CHILLED SPARKLING FILTERED INSTANTLY ON TAP
BOILING CHILLED SPARKLING FILTERED INSTANTLY ON TAP Come home to Billi. Meet Billi, the world s most innovative drinking water appliance. Billi is not only smarter Billi is more beautiful. The brilliance
More informationPROPOSED NEW BUILDING
HYDRAULIC DRAWINGS MATERIALS SERVICES TO BE CONSTRUCTED FROM MATERIAL AS LISTED BELOW UNLESS NOTED OTHER WISE SHOWN ON DRAWINGS. SERVICE MATERIAL REMARKS SEWER DRAINAGE upvc SOLVENT WELDED JOINTS SEWER
More informationCHAPTER 31. VENTS Reserved 2003 INTERNATIONAL RESIDENTIAL CODE 425R
CHAPTER 31 VENTS Reserved 2003 INTERNATIONAL RESIDENTIAL CODE 425R This page left intentionally blank. 426R 2003 INTERNATIONAL RESIDENTIAL CODE For SI: PIPE SIZE (inches) TABLE P3107.3 COMMON VENT SIZES
More informationINTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS MATERIAL AND PROPERTY STANDARD FOR
INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS MATERIAL AND PROPERTY STANDARD FOR EARLY-CLOSURE REPLACEMENT FLAPPERS OR EARLY-CLOSURE REPLACEMENT FLAPPER WITH MECHANICAL ASSEMBLIES IAPMO
More informationHouse Drainage System. Building Utility & Services
House Drainage System Building Utility & Services Syllabus House Drainage: principles of house drainage, pipes and traps, Classification of traps: nahni trap, interception trap, grease-trap, sanitary fittings,
More informationSTACKS AND STACK VENTS
CHAPTER 9 VENTS SECTION 901 GENERAL 901.1 Scope. The provisions of this chapter shall govern the materials, design, construction and installation of vent systems. 901.2 Trap seal protection. The plumbing
More informationCompany : VALSIR LOCALITA MERLARO 2 IT VESTONE (BS)
SANITARY APPLIANCES CSTB attests that the products referred to in the appendix comply with the characteristics described in the certification system NF 017 (revision 26) after evaluation according to the
More informationINSTALLATION AND CARE INSTRUCTIONS
INSTALLATION AND CARE INSTRUCTIONS THESE INSTRUCTIONS MUST BE READ BEFORE INSTALLATION IS ATTEMPTED. FAILURE TO DO SO MAY COMPROMISE WARRANTY. FOLLOWING INSTALLATION PLEASE LEAVE ALL PAPERWORK WITH CLIENT
More informationSpecial Requirements For Health Care Facilities
Chapter 14 Special Requirements For Health Care Facilities 14.1 GENERAL This Chapter applies to special fixtures and systems that occur in health care facilities and to the special plumbing requirements
More informationStainless Steel Sanitaryware
Stainless Steel Sanitaryware www.purusinternational.com Stainless Steel Sanitaryware At Purus you can find stainless steel sanitary products for your home as well as for public buildings. You can choose
More informationCHAPTER VI BUILDING PLUMBING
CHAPTER VI BUILDING PLUMBING 6.1. INTRODUCTION The chapter covers questions related to water demand, distribution and drainage. The basic principles for planning and installing common plumbing systems
More informationCHAPTER 9 VENTS. run undiminished in size and as directly as possible from the building drain through to the open air above the roof.
CHAPTER 9 VENTS SECTION 90 GENERAL run undiminished in size and as directly as possible from the building drain through to the open air above the roof. 90. Scope. The provisions of this chapter shall govern
More informationSummer Works Scheme 2010
WCMS 01/2009 TO: PRIMARY AND POST PRIMARY SCHOOL AUTHORITIES Summer Works Scheme 2010 Devolved Capital Grants for Water Conservation Measures in Primary and Post Primary School Buildings Guide for School
More informationCHAPTER 9 VENTS SECTION
CHAPTER 9 VENTS SECTION 901 GENERAL 901.1 Scope. The provisions of this chapter shall govern the materials, design, construction and installation of vent systems. 901.2 Trap seal protection. The plumbing
More informationCRAFTSMAN EXAMINATION, JUNE 2007 PLUMBING QUESTION AND ANSWER BOOKLET. Time allowed THREE hours
Affix label with Candidate Code Number here. If no label, enter candidate Number if known No. 995 CRAFTSMAN EXAMINATION, JUNE 007 PLUMBING INSTRUCTIONS QUESTION AND ANSWER BOOKLET Time allowed THREE hours
More informationGARCIA GALUSKA DESOUSA Consulting Engineers
L#58619/Page 1/November 1, 2017 PLUMBING Executive Summary: Presently, the Plumbing Systems serving the building are cold water, hot water, sanitary, waste and vent system, storm drain piping, and natural
More informationPlumbing Guidelines 2012 IBC/ANSI A
Plumbing Guidelines 2012 IBC/ANSI A117.1-2009 This document provides basic and fundamental information for accessible plumbing fixtures, toilet rooms and bathing facilities. It is not intended to replace
More informationRepair and Maintenance Manual for Residential Quarters under Licence Agreement
Repair and Maintenance Manual for Residential Quarters under Licence Agreement Version Issue Date 4.0 (Third Issue) January 2017 CONTENTS Page 1. Introduction 2 2. Conditions for the Provision of Repair
More informationREGISTRATION EXAMINATION, NOVEMBER 2017 TRADESMAN PLUMBER ANSWER SCHEDULE
No. 9192 REGISTRATION EXAMINATION, NOVEMBER 2017 TRADESMAN PLUMBER ANSWER SCHEDULE Plumbers, Gasfitters and Drainlayers Board, 2017. All rights reserved. No part of this publication may be reproduced by
More informationIFO6820. Ifo Sign Junior Toilet S Trap. Product Code. Call
When tested in accordance with Standard AS/NZS 6400 For more information and to compare products, refer to: Ifo Sign Junior Toilet S Trap One-piece free standing junior toilet. Suitable for child care
More informationPipe Sizing Table. Hydraulic Load Served (fixture units)
MODULE 1 INTRODUCTION Notes: A Pipe Type Horizontal branch Pipe Sizing Table Hydraulic Load Served (fixture units) Size (in.) Code Reference 2 + 1.5 = 3.5 2 7.4.9.1.(1) B Soil stack 13.5 + 13.5 = 27 3
More informationPlumbing Guidelines 2015 Minnesota Accessibility Code Based on the 2012 IBC and 2009 ANSI A117.1
Plumbing Guidelines 2015 Minnesota Accessibility Code Based on the 2012 IBC and 2009 ANSI A117.1 This document provides basic and fundamental information for accessible plumbing fixtures, toilet rooms
More informationPro Vent TM. Provent Systems Inc Capital Circle Lawrenceville Georgia
Pro Vent TM Guide to Design and Usage Provent Single System Handling Installation Corrosion Ease Simplicity Resistance IPMO Copyright (c) 2014, Pro Vent Systems Inc., plus *2016 Revisions ll Rights Reserved
More informationWavin HepvO Self-Sealing Waste Valve
Waste water drainage PRDUCT AND INSTALLATIN MANUAL Wavin Hepv Self-Sealing Waste Valve Introduction to Hepv Hepv is a unique self-sealing waste valve that prevents the escape of foul sewer air from waste
More informationInstallation Systems. Safety and durability
Installation Systems Safety and durability Installation Systems Safety and durability Wide range of solutions Duplo WC Compact With Roca s Duplo systems you obtain all the installation flexibility for
More informationWC-Unit. Assembly instructions I00127_NOV 16
IföSign 6860 WC-Unit 6860 Assembly instructions I00127_NOV 16 A joint government and industry program Licence No. 0058 When tested in accordance with Standard AS/NZS 6400 For more information and to compare
More informationInstallation & User Guide
Installation & User Guide Dual-Flush Toilet NOTE: If your new toilet pan has Side Entry holes, please ignore this installation guide and refer to document # 1265059-A2. 1102602-A2-J Tools And Materials
More informationAS/NZS :2015. Plumbing and drainage AS/NZS :2015. Part 4: Heated water services. Australian/New Zealand Standard
AS/NZS 3500.4:2015 Incorporating Amendment No. 1 Australian/New Zealand Standard Plumbing and drainage Part 4: Heated water services Superseding AS/NZS 3500.4:2003 AS/NZS 3500.4:2015 AS/NZS 3500.4:2015
More informationAccreditation Schedule
JOINT ACCREDITATION SYSTEM OF AUSTRALIA AND NEW ZEALAND HELPING MARKETS WORK BETTER AUSTRALIA FECCA House, 4 Phipps Close, Deakin, ACT 2600 PO Box 304, Deakin West, ACT 2605 P: +61 (0)2 6232 2000 NEW ZEALAND
More informationIFO6872. Ifo Sign Toilet Increased Height P Trap AS1428.1:2009. Product Code. Call
When tested in accordance with Standard AS/NZS 60 For more information and to compare products, refer to: Ifo Sign Toilet Increased Height P Trap AS1428.1:2009 White freestanding toilet suite with 460mm
More informationHUTS SANITATION TANKS, DRUMS & BINS PIPING
Product Information HUTS SANITATION TANKS, DRUMS & BINS PIPING THE KING JOHN The King John Rectangular Hut is ideally suited for events and contractors, for professional teams on construction sites and
More informationDEPARTMENT OF TRADE AND INDUSTRY DEPARTEMENT VAN HANDEL EN NYWERHEID. NATIONAL REGULATOR FOR COMPULSORY SPECIFICATIONS ACT (Act 5 of 2008)
STAATSKOERANT, 19 NOVEMBER 2010 No.33763 11 No. R. 1072 DEPARTMENT OF TRADE AND INDUSTRY DEPARTEMENT VAN HANDEL EN NYWERHEID 19 November 2010 NATIONAL REGULATOR FOR COMPULSORY SPECIFICATIONS ACT (Act 5
More informationdoc.m rimless super pack
433 APRIL 2013 * * LESS ABLE 12:1:434 doc.m rimless super pack modern rimless design 4 litre flush Doc.M rimless super pack with white grab rails & seat. Right hand installation shown. Doc.M rimless super
More informationASME STANDARDS IN MODEL CODES
STANDARDS IN MODEL CODES ASME Name Model Code With Year of Referenced IPC IRC UPC 2009 NSPC A112.1.2 Air Gaps in Plumbing 2004 2004 2004 2004 A112.1.3 Air Gap Fittings For Use With Plumbing, Appliances
More informationDOMESTIC & COMMERCIAL PLUMBING SYSTEMS FURTHER INFOMATION
DOMESTIC & COMMERCIAL PLUMBING SYSTEMS FURTHER INFOMATION Hot and Cold water distribution pipework Sizing of pipework For everyday plumbing in an average sized building a rule of thumb can be used when
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17065:2012
SCOPE OF ACCREDITATION TO ISO/IEC 17065:2012 TEi-LISTING SERVICES 3455 S. 500 W. Salt Lake City, UT 84115 Mrs. Alona MacGregor (Authorized Representative) Phone: 801 262 1868 Email: alona@tei-test.com
More informationAustralian/New Zealand Standard
AS/NZS 3500.4:2003 (Incorporating Amendment Nos 1 and 2) AS/NZS 3500.4:2003 Australian/New Zealand Standard Plumbing and drainage Part 4: Heated water services AS/NZS 3500.4:2003 This Joint Australian/New
More informationPANACHE ORDERING INFORMATION NOTES T01-A INSTALLATION INSTRUCTIONS
PANACHE INSTALLATION INSTRUCTIONS VITREOUS CHINA TWO-PIECE TOILET S-TRAP 305mm/P-TRAP 180mm K-18182T/K-18182T-S Please read these instructions carefully to familiarize yourself with the required tools,
More informationRESTROOMS. Proper daily cleaning procedures. Custodial Best Practices
RESTROOMS Proper daily cleaning procedures Custodial Best Practices Cleaning tools Toilet bowl brush stiff bristle brush used for basic scrubbing and cleaning of toilets Toilet bowl swab soft nylon applicator
More informationProVent Systems Plumbing Fundamentals. Educational Literature. Comparison of ProVent Design Rules and The International Plumbing Code
ProVent Systems Plumbing Fundamentals Educational Literature Comparison of ProVent Design Rules and The International Plumbing Code Guide to Contents Topics and Descriptions Page Interior views of the
More informationINSTALLATION AND CARE INSTRUCTIONS
INSTALLATION AND CARE INSTRUCTIONS THESE INSTRUCTIONS MUST E READ EFORE INSTALLATION IS ATTEMPTED. FAILURE TO DO SO MAY COMPROMISE WARRANTY. FOLLOWING INSTALLATION PLEASE LEAvE ALL PAPERWORK WITH CLIENT
More informationMatrix of changes for the National Standard Plumbing Code July 2013
Matrix of changes for the National Standard Plumbing Code July 2013 Item # Section Number Person Submitting Change Committee Action 10-77 10.20.8 and Table 3.1.3 XI Certification 10-82 12.16 Size and Lengths
More informationDissecting Rainwater Pump Energy Use in Urban Households
Dissecting Rainwater Pump Energy Use in Urban Households Tjandraatmadja, G. 1, Pollard, C. 1, Sharma, A. 1 and Gardner, T. 2 1 CSIRO Land and Water, PO Box 56, Highett,Vic 3190 2 CSIRO Land and Water,
More informationCHAPTER 5 Water, Plumbing, and Waste
CHAPTER 5 Water, Plumbing, and Waste Parts 5-1 Water 5-2 Plumbing System 5-3 Mobile Water Tank 5-4 Sewage, Other Liquid Waste, and Rainwater 5-5 Refuse, Recyclables, and Returnables 5-1 Water 5-101 Source
More informationRestrooms. Proper daily cleaning procedures. Custodial Best Practices
Restrooms Proper daily cleaning procedures Custodial Best Practices Cleaning tools Bowl brush stiff bristle brush used for basic scrubbing and cleaning of toilets and urinals. Bowl swab soft nylon applicator
More informationCompany : DURAVIT POSTFACH 240 WERDERSTRASSE 36 DE-D HORNBERG
SANITARY APPLIANCES CSTB attests that the products referred to in the appendix comply with the characteristics described in the certification system NF 017 (revision 26) after evaluation according to the
More informationKaress ORDERING INFORMATION NOTES T01-A INSTALLATION INSTRUCTIONS
Karess INSTALLATION INSTRUCTIONS VITREOUS CHINA TWO-PIECE TOILET S-TRAP 305mm K-5331T-S S-TRAP 400mm K-5471T-S Please read these instructions carefully to familiarize yourself with the required tools,
More informationMechanical Inspection Plumbing
0811 Fixtures Sinks, drinking fountains, water closets, showers, etc. Classroom Sinks. Classroom sinks (19) are enameled cast iron self rimming side ledge with gooseneck faucet trim with index handles,
More informationAQUA GENIUS AQUA GENIUS. Boiling, chilled, still, sparkling, filtered. Aqua Genius, that's Billi.
AQUA GENIUS AQUA GENIUS Boiling, chilled, still, sparkling, filtered. Aqua Genius, that's Billi. www.billi.com.au Water, the elixir of life. Billi brings water back to its purest elemental form. A four
More informationCompany : DURAVIT POSTFACH 240 WERDERSTRASSE 36 DE-D HORNBERG
SANITARY APPLIANCES CSTB attests that the products referred to in the appendix comply with the characteristics described in the certification system NF 017 (revision 26) after evaluation according to the
More informationAPPENDIX L ALTERNATE PLUMBING SYSTEMS
ALTERNATE PLUMBING SYSTEMS L 1.0 General. L 1.1 Applicability. The intent of this appendix is to provide clarification of procedures for the design and approval of engineered plumbing systems, alternate
More informationMechanical System Description
1. Building Description: Mechanical System Description The building is a Type-1B construction, 9-levels, non-high rise building with 67 affordable family housing units. The first level of the structure
More informationSECTION PLUMBING
SECTION 22 10 00 PLUMBING PART 1 GENERAL 1.1 WORK INCLUDED A. Furnish all labor, material and equipment necessary for the complete installation of the sanitary sewer system (including soil and vent piping),
More informationARCHERTM ORDERING INFORMATION NOTES T01-C INSTALLATION INSTRUCTIONS VITREOUS CHINA ONE-PIECE TOILET K-3639T/K-3639T-C
ARCHER TM INSTALLATION INSTRUCTIONS VITREOUS CHINA ONE-PIECE TOILET K-3639T/K-3639T-C Please read these instructions carefully to familiarize yourself with the required tools, materials, and installation
More informationModular Grease Trap MGTA
Modular Grease Trap MGTA and MGTA) Installation Requirements Installation Water Requirements Corporation Water Corporation 22 Ethel Ave Brookvale NSW 2100 Postal: PO Box 255 Collaroy NSW 2097 Freecall
More informationENERGY SA ERS ELECTRIC AND DIGITAL CONTROLLED WATER HEATERS. The most advanced way to make hot water
ENERGY SA ERS Over 25 years experience manufacturing quality electric water heaters ELECTRIC AND DIGITAL CONTROLLED WATER HEATERS The most advanced way to make hot water ELWA offers a range of electric
More information3/4.8 AERODYNE 3/4.8L CLASS FIVE+
3/4.8 AERODYNE 3/4.8L CLASS FIVE+ INSTALLATION INSTRUCTIONS VITREOUS CHINA SKIRTED TRAPWAY ONE-PIECE TOILET S-TRAP 305mm K-3869T/K-3869T-S S-TRAP 400mm K-4165T/K-4165T-S Please read these instructions
More information2006 Thermaco, Inc. All rights reserved Patented/Patents Pending Specifications subject to change without notice
One to Three Compartment Sink When planning a multiple fixture discharge into a single Big Dipper, establish the size unit required by following the method outlined in the sizing section of this manual.
More informationGulfport, Mississippi 21 May 2007
G PLUMBING GENERAL REQUIREMENTS The D-BC shall design the plumbing system to comply with this criteria and the Plumbing Code. Piping shall be shown on the same plan as the fixtures being served. Pipe size
More informationThis chapter investigates domestic
207 SANITATION This chapter investigates domestic sanitation systems. It looks at the many different sanitary appliances available and the systems of above-ground sanitation pipework that they are connected
More informationThere are several designs of toilets. These are close coupled, low level, high level, back to wall, and wall- hung.
There are several designs of toilets. These are close coupled, low level, high level, back to wall, and wall- hung. Close coupled is floor mounted with the cistern against the wall and resting on the back
More informationPush Button Electronic Timer. 31VETR Series. Installation Instructions
Push Button Electronic Timer Series Installation Instructions Contents 1.0 Product Range... 3 2.0 Description... 3 3.0 Features... 3 4.0 Important Warnings... 3 5.0 Timer Control... 4 5.1 Push Button Control...
More informationLincoln Public Schools
Lincoln Public Schools School Building Committee Meeting February 13, 2019 Today s Agenda 1. Review Updated Site Plan 2. Review and Approve OPR 3. Review MEP Systems 4. Review Progress Energy Model Review
More informationLecture : Introduction to building services I - Plumbing & Drainage Services 22 September 2016
SBS4113 Architecture & Buildings http://ibse.hk/sbs4113/ Lecture : Introduction to building services I - Plumbing & Drainage Services 22 September 2016 Guest teacher : Ir. Eur Ing. K P Cheung Faculty of
More informationCompany : ECZACIBASI YAPI GERECLERI A.S. BUYUKDERE CAD. No. 185 TR LEVENT-ISTANBUL
SANITARY APPLIANCES CSTB attests that the products referred to in the appendix comply with the characteristics described in the certification system NF 017 (revision 26) after evaluation according to the
More informationAdd the luxury of extra facilities almost anywhere you choose
SANIFLO RANGE OF SMALL-BORE SANITARY SYSTEMS Add the luxury of extra facilities almost anywhere you choose Pumps Macerators Inclusive Products see website for latest product updates: Add luxury, add value.
More informationCondensing Heat Exchanger Suitable Gas Fired Ideal GT & GTE boiler ranges
Condensing Heat Exchanger Suitable Gas Fired Ideal GT & GTE boiler ranges 2 The new GT Condenser provides higher efficiencies and low running costs from the Ideal range of pressurised gas boilers. Extracting
More informationApproved Basic Trade Waste Pre-treatment Products
Approved Basic Trade Waste Pre-treatment Products Reviewed 05/02/2016 This list shows the basic pre-treatment devices approved by SA Water for connection to its sewerage system. Dischargers may choose
More informationMULTISAN Fully automatic sewage and waste water pump
MULTISAN Fully automatic sewage and waste water pump Multisan is suitable for pumping waste water from toilets, bidets, showers and basins from rooms which are below the sewer level, or conditions where
More informationPLUMBING INSTALLATIONS
PLANNING, PROPERTY AND DEVELOPMENT DEPARTMENT PLUMBING INSTALLATIONS A homeowner guide to plumbing requirements for single-family dwellings November 2017 contents Permit Requirements... 3 Inspection Requirements...
More informationFlorida Building Code 5 th Edition (2014) Building. Broward County Edition Loose-leaf Supplement
Board of Rules and Appeals FBC 5 th Edition (2014)- Building - Supplement No. 1 June 30, 2015 Florida Building Code 5 th Edition (2014) Building File removed pages for reference. Broward County Edition
More informationPLUMBING FIXTURES CHAPTER 27
CHAPTER 27 PLUMBING FIXTURES SECTION P2701 FIXTURES, FAUCETS AND FIXTURE FITTINGS P2701.1 Quality of fixtures. Plumbing fixtures, faucets and fixture fittings shall be constructed of approved materials,
More informationProduct Catalogue WB Engineering Containers. fast inexpensive safe flexible certified
Product Catalogue WB Engineering Containers fast inexpensive safe flexible certified Table of Content Product Catalogue Key data WBEC - Standard & Premium Key data WBEC - Standard model Key data WBEC Premium
More informationSanitary & Hospital Equipment
Sanitary & Hospital Equipment Introduction With 40 years experience, M&G Olympic Products has maintained its position as a leading specialist in the design, manufacture and installation of custom built
More informationCompany : ECZACIBASI YAPI GERECLERI A.S. BUYUKDERE CAD. No. 185 TR LEVENT-ISTANBUL
SANITARY APPLIANCES CSTB attests that the products referred to in the appendix comply with the characteristics described in the certification system NF 017 (revision 26) after evaluation according to the
More informationThis document is a preview generated by EVS
TECHNICAL REPORT RAPPORT TECHNIQUE TECHNISCHER BERICHT CEN/TR 17221 April 2018 ICS 91.140.70 English Version Guidance on the application of CE marking and preparation of Declaration of Performance for
More informationInstallation & User Guide
Installation & User Guide MILANO Dual-Flush Two Piece Toilet MIRAGE-S MIRAGE-P DOMANI ELITE DELANO-S DELANO-P 1104782-A2-B Tools and Materials Thank You For Choosing Englefield Thank You For Choosing Englefield.
More informationGRUNDFOS SOLOLIFT2 GRUNDFOS SOLOLIFT2 ENGINEERED BY THE WORLD S LEADING PUMP COMPANY FOR PERFORMANCE, RELIABILITY AND EASY FITTING FROM THE OUTSET.
GRUNDFOS The Perfect Fit GRUNDFOS ENGINEERED BY THE WORLD S LEADING PUMP COMPANY FOR PERFORMANCE, RELIABILITY AND EASY FITTING FROM THE OUTSET. 800 POINTS INTRODUCTION - GET INTRODUCED TO A NEW GENERATION
More informationRevision th July The Pinnacle Apartments. Standard Specifications and Finishes
Revision 4 24 th July 2018 1. Introduction This specification has been prepared to assist Purchasers in their understanding of the overall scheme, and their rights and obligations as Purchasers. 2. Standard
More informationLevel I Chapter 1 Worksheet
Chapter 1 Worksheet 1. For applicability requirements of the Plumbing Code, refer to: a. Building Code b. Administration and Enforcement Code c. Plumbing Code d. Residential Code 2. The provisions of the
More information