Level 1. Certificate of Conformity. Australian Certification Services Pty Ltd grants to the WaterMark User: Wallgate Ltd. Trading as Wallgate Ltd

Size: px
Start display at page:

Download "Level 1. Certificate of Conformity. Australian Certification Services Pty Ltd grants to the WaterMark User: Wallgate Ltd. Trading as Wallgate Ltd"

Transcription

1 Level 1 Certificate of Conformity Australian Certification Services Pty Ltd grants to the WaterMark User: Trading as the right to use the WaterMark as shown above in conjunction with the Certificate No. on product/s as identified in the WaterMark Schedule and as listed on the WaterMark database which have been shown to comply with the relevant Standard/s and level of certification referred to below. The WaterMark User is granted a licence to use the WaterMark subject to the rules governing the use of the WaterMark. Product Type: Evaluated to: Sanitary Fixtures and Flushing Devices AS :2005 Water Closets (WC) Part 1: Pans AS :1999 Amdt Amdt AS :1999 Amdt Amdt Water closet (WC) pans of 6/3 L capacity or proven equivalent Part 2: Cistern ATS :2004 Technical Specification for plumbing and drainage products Part 020: Flushing valves for water closets and urinals - For use with mains supply ATS :2004 Technical Specification for plumbing and drainage products Part 021: Flushing valves for water closets and urinals For use with break tank supply Issue Date 23 rd August 2016 Paul Greig Initial Issue Date: 29 th April 2013 General Manager Expiry Date: 28 th April 2018 Certificate No.: This certificate remains the property of Australian Certification Services Pty Ltd WaterMark Level 1 certification is a conformity assessment scheme based on ISO Guide 67 (system 5) Page 1 of 6

2 WaterMark Certification Schedule The WaterMark User Certification Standards: AS :2005 Water Closets (WC) Part 1: Pans AS :1999 Amdt Amdt CWC_80 P Trap CWC_100 Solid Surface Material Water Closet Pan Wall Hung P Trap Nominal Flush Volume 6L or 4.5L CWC_150 P Trap CWC_170_L Left P Trap CWC_170_R Right P Trap CWC_88 CWC_155 CWC_177_L Left CWC_177_R Right CWC_250 P Trap Page 2 of 6

3 CWC_255 CWC_270_L CWC_270_R CWC_280 CWC_288 Left P Trap Right P Trap P Trap Page 3 of 6

4 The WaterMark User Certification Standards: AS :1999 Amdt Amdt Water closet (WC) pans of 6/3 L capacity or proven equivalent Part 2: Cistern CISTFV01LH_AUS Plastic Bodied In Wall Dual Flush Electronically Operated Water Closet Cistern Left Hand Inlet Flush Volume 6/3L or 4.5/3L Page 4 of 6

5 The WaterMark User Certification Standards: ATS :2004 Technical Specification for plumbing and drainage products Part 020: Flushing valves for water closets and urinals - For use with mains supply DFKIT01 DN32 Flush Valve Electronically Operated Dual Flush Volume 6/3L or 4.5/3L DFKIT03 DN25 Flush Valve Electronically Operated Dual Flush Volume 6/3L or 4.5/3L DFKIT-CWU-01- HYD DN15 Pneumatically activated Urinal Flush Valve with included Pipe Interrupter Device (PID) Flush Volume 0.3L per Flush for use with Single Stall Wall Hung Urinals Page 5 of 6

6 The WaterMark User Certification Standards: ATS :2004 Technical Specification for plumbing and drainage products Part 021: Flushing valves for water closets and urinals For use with break tank supply FVA007 DN32 Flush Valve Electronically Operated Break Tank Supplied Dual Flush Volume 6/3L or 4.5/3L FVA008 DN25 Flush Valve Electronically Operated Break Tank Supplied Dual Flush Volume 6/3L or 4.5/3L Page 6 of 6

Level 2. Certificate of Conformity. Australian Certification Services Pty Ltd grants to the WaterMark User: Saniflo (Australasia) Pty Ltd

Level 2. Certificate of Conformity. Australian Certification Services Pty Ltd grants to the WaterMark User: Saniflo (Australasia) Pty Ltd Level 2 Certificate of Conformity Australian Certification Services Pty Ltd grants to the WaterMark User: Saniflo (Australasia) Pty Ltd Trading as Saniflo (Australasia) Pty Ltd the right to use the WaterMark

More information

STUDENT NOTES Plan, size and layout sanitary pipe work and fixtures

STUDENT NOTES Plan, size and layout sanitary pipe work and fixtures 4. SANITARY PLUMBING FULLY VENTED SYSTEM On completion of this module, the student should be able to: Design, install and develop bills of quantities for a fully vented modified system for commercial and

More information

Level 1. Certificate of Conformity. Australian Certification Services Pty Ltd grants to the WaterMark User: Logi Dezign. Trading as Logi Dezign

Level 1. Certificate of Conformity. Australian Certification Services Pty Ltd grants to the WaterMark User: Logi Dezign. Trading as Logi Dezign Level 1 Certificate of Conformity Australian Certification Services Pty Ltd grants to the WaterMark User: Logi Dezign Trading as Logi Dezign the right to use the WaterMark as shown above in conjunction

More information

1 WATERMARK CERTIFICATION SCHEME SCHEDULE OF PRODUCTS This document was adopted 1 August 2017 and replaced the WaterMark Schedule of Specifications

1 WATERMARK CERTIFICATION SCHEME SCHEDULE OF PRODUCTS This document was adopted 1 August 2017 and replaced the WaterMark Schedule of Specifications 1 WATERMARK CERTIFICATION SCHEME SCHEDULE OF PRODUCTS This document was adopted 1 August 2017 and replaced the WaterMark Schedule of Specifications Product type Application Specification Appliances Bedpan

More information

Certificate of Conformity. Australian Certification Services Pty Ltd grants to the WaterMark User: Aquatica NZ Limited. Trading as Aquatica NZ Limited

Certificate of Conformity. Australian Certification Services Pty Ltd grants to the WaterMark User: Aquatica NZ Limited. Trading as Aquatica NZ Limited Certificate of Conformity Australian Certification Services Pty Ltd grants to the WaterMark User: Aquatica NZ Limited Trading as Aquatica NZ Limited the right to use the WaterMark as shown above in conjunction

More information

WINNER 2. Cod BLOCK. Cod BLOCK AUTOPORTANTE MANUAL SYSTEM PUSH CONTROL PLATES COLOURS. Cod Cod.

WINNER 2. Cod BLOCK. Cod BLOCK AUTOPORTANTE MANUAL SYSTEM PUSH CONTROL PLATES COLOURS. Cod Cod. Cod. 863302 BLOCK WINNER 2 In-wall flush cistern with dual flush 6/3 or 7.5/4 litres. To obtain a 6/7.5 flush + STOP the push buttons with single flush can be employed. The flush cistern is mounted on

More information

bathroom collection National Customer Service Number the complete range of

bathroom collection   National Customer Service Number the complete range of bathroom collection the complete range of vitreous china basins, vanity cabinets, toilet suites and mixer taps to complement any home. www.everhard.com.au National Customer Service Number 13 1926 Vitreous

More information

GIANT. Little. Guidelines for Sizing. Pump Company. Sewage Pumps & Systems. Sewage Pumps & Systems

GIANT. Little. Guidelines for Sizing. Pump Company. Sewage Pumps & Systems. Sewage Pumps & Systems Sewage Pumps & Systems GIANT Little Pump Company Guidelines for Sizing Sewage Pumps & Systems These guidelines cover the steps that need to be taken to accurately select the correct sewage pump and applicable

More information

Trade of Plumbing. Module 2: Domestic Hot and Cold Water Service Unit 11: Sanitary Appliances Phase 2

Trade of Plumbing. Module 2: Domestic Hot and Cold Water Service Unit 11: Sanitary Appliances Phase 2 Trade of Plumbing Module 2: Domestic Hot and Cold Water Service Unit 11: Sanitary Appliances Phase 2 Table of Contents List of Figures... 4 List of Tables... 5 Document Release History... 6 Module 2 Domestic

More information

2. Sanitary Plumbing General Installation Requirements

2. Sanitary Plumbing General Installation Requirements 2. Sanitary Plumbing General Installation Requirements On completion of this section, students should be able to: Identify and describe sanitary plumbing installations requirements in accordance with the

More information

Wastewater. Guidelines for Sizing mscdirect.com. Call MSC today to learn about the latest LittleGiant products.

Wastewater. Guidelines for Sizing mscdirect.com. Call MSC today to learn about the latest LittleGiant products. Wastewater Guidelines for Sizing Features These guidelines cover the steps which need to be taken to accurately select the correct sewage pump and applicable systems to use in sewage ejectors. Work through

More information

CRAFTSMAN EXAMINATION, NOVEMBER 2009 PLUMBING QUESTION AND ANSWER BOOKLET. Time allowed THREE hours

CRAFTSMAN EXAMINATION, NOVEMBER 2009 PLUMBING QUESTION AND ANSWER BOOKLET. Time allowed THREE hours Affix label with Candidate Code Number here. If no label, enter candidate Number if known No. 9195 CRAFTSMAN EXAMINATION, NOVEMBER 2009 PLUMBING INSTRUCTIONS QUESTION AND ANSWER BOOKLET Time allowed THREE

More information

WATER HAMMER ARRESTORS & MISC. SPECIALTIES

WATER HAMMER ARRESTORS & MISC. SPECIALTIES TABLE OF CONTENTS Pictorial Index Water Hammer Arrestors Certification Sizing & Placement Backwater Valves Typical Installations Trap Seal Primers Compliance Pressure & Flow Characteristics Typical Installations

More information

Read Only Document Not For Distribution

Read Only Document Not For Distribution Chapter 5 Traps, Cleanouts and Backwater Valves 5.1 SEPARATE TRAPS FOR EACH FIXTURE a. Plumbing fixtures shall be separately trapped by a water seal trap placed as close as possible to the fixture outlet.

More information

REGISTRATION EXAMINATION, NOVEMBER 2014 LICENSED PLUMBER QUESTION AND ANSWER BOOKLET. Time allowed THREE hours

REGISTRATION EXAMINATION, NOVEMBER 2014 LICENSED PLUMBER QUESTION AND ANSWER BOOKLET. Time allowed THREE hours Affix label with Candidate Code Number here. If no label, enter candidate Number if known No. 9192 REGISTRATION EXAMINATION, NOVEMBER 2014 LICENSED PLUMBER INSTRUCTIONS QUESTION AND ANSWER BOOKLET Time

More information

Sanitary Drainage Systems

Sanitary Drainage Systems 11.1 MATERIALS See Section 3.1. Sanitary Drainage Systems 11.2 BUILDING SEWERS AND BUILDING DRAINS 11.2.1 Sewer or Drain in Filled Ground Chapter 11 Building sewers or building drains that are installed

More information

Fresh Water Availability

Fresh Water Availability Water Efficient Products India (WEP I) A Step in the Right Direction Fresh Water Availability Presentation By, Gurmit Singh Arora Indian Plumbing Association (Chairman Mumbai Chapter) Indian Green Building

More information

Novelli Sanitaryware Collection 2010

Novelli Sanitaryware Collection 2010 Novelli Sanitaryware Collection 00 Building Products Pty Ltd Lifestyle Series - Toilet Suites, Basins and Vessels Building Products Pty Ltd Cara Pedestal Basin Armanti Verno Bidet and Cara Back-To-Wall

More information

Installation Information User Manual

Installation Information User Manual 1-5 Anzac Avenue Smeaton Grange NSW 2567 is a division of BioSeptic Pty Ltd - ABN 95 056 461 226 Ph: 02 4629 6633 Fax: 02 4629 6677 Email: sales@sydneywatertanks.com.au Web: www.sydneywatertanks.com.au

More information

Read Only Document Not For Distribution

Read Only Document Not For Distribution Chapter 14 Special Requirements For Health Care Facilities 14.1 GENERAL This Chapter applies to special fixtures and systems that occur in health care facilities and to the special plumbing requirements

More information

BOILING CHILLED SPARKLING FILTERED INSTANTLY ON TAP

BOILING CHILLED SPARKLING FILTERED INSTANTLY ON TAP BOILING CHILLED SPARKLING FILTERED INSTANTLY ON TAP Come home to Billi. Meet Billi, the world s most innovative drinking water appliance. Billi is not only smarter Billi is more beautiful. The brilliance

More information

PROPOSED NEW BUILDING

PROPOSED NEW BUILDING HYDRAULIC DRAWINGS MATERIALS SERVICES TO BE CONSTRUCTED FROM MATERIAL AS LISTED BELOW UNLESS NOTED OTHER WISE SHOWN ON DRAWINGS. SERVICE MATERIAL REMARKS SEWER DRAINAGE upvc SOLVENT WELDED JOINTS SEWER

More information

CHAPTER 31. VENTS Reserved 2003 INTERNATIONAL RESIDENTIAL CODE 425R

CHAPTER 31. VENTS Reserved 2003 INTERNATIONAL RESIDENTIAL CODE 425R CHAPTER 31 VENTS Reserved 2003 INTERNATIONAL RESIDENTIAL CODE 425R This page left intentionally blank. 426R 2003 INTERNATIONAL RESIDENTIAL CODE For SI: PIPE SIZE (inches) TABLE P3107.3 COMMON VENT SIZES

More information

INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS MATERIAL AND PROPERTY STANDARD FOR

INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS MATERIAL AND PROPERTY STANDARD FOR INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS MATERIAL AND PROPERTY STANDARD FOR EARLY-CLOSURE REPLACEMENT FLAPPERS OR EARLY-CLOSURE REPLACEMENT FLAPPER WITH MECHANICAL ASSEMBLIES IAPMO

More information

House Drainage System. Building Utility & Services

House Drainage System. Building Utility & Services House Drainage System Building Utility & Services Syllabus House Drainage: principles of house drainage, pipes and traps, Classification of traps: nahni trap, interception trap, grease-trap, sanitary fittings,

More information

STACKS AND STACK VENTS

STACKS AND STACK VENTS CHAPTER 9 VENTS SECTION 901 GENERAL 901.1 Scope. The provisions of this chapter shall govern the materials, design, construction and installation of vent systems. 901.2 Trap seal protection. The plumbing

More information

Company : VALSIR LOCALITA MERLARO 2 IT VESTONE (BS)

Company : VALSIR LOCALITA MERLARO 2 IT VESTONE (BS) SANITARY APPLIANCES CSTB attests that the products referred to in the appendix comply with the characteristics described in the certification system NF 017 (revision 26) after evaluation according to the

More information

INSTALLATION AND CARE INSTRUCTIONS

INSTALLATION AND CARE INSTRUCTIONS INSTALLATION AND CARE INSTRUCTIONS THESE INSTRUCTIONS MUST BE READ BEFORE INSTALLATION IS ATTEMPTED. FAILURE TO DO SO MAY COMPROMISE WARRANTY. FOLLOWING INSTALLATION PLEASE LEAVE ALL PAPERWORK WITH CLIENT

More information

Special Requirements For Health Care Facilities

Special Requirements For Health Care Facilities Chapter 14 Special Requirements For Health Care Facilities 14.1 GENERAL This Chapter applies to special fixtures and systems that occur in health care facilities and to the special plumbing requirements

More information

Stainless Steel Sanitaryware

Stainless Steel Sanitaryware Stainless Steel Sanitaryware www.purusinternational.com Stainless Steel Sanitaryware At Purus you can find stainless steel sanitary products for your home as well as for public buildings. You can choose

More information

CHAPTER VI BUILDING PLUMBING

CHAPTER VI BUILDING PLUMBING CHAPTER VI BUILDING PLUMBING 6.1. INTRODUCTION The chapter covers questions related to water demand, distribution and drainage. The basic principles for planning and installing common plumbing systems

More information

CHAPTER 9 VENTS. run undiminished in size and as directly as possible from the building drain through to the open air above the roof.

CHAPTER 9 VENTS. run undiminished in size and as directly as possible from the building drain through to the open air above the roof. CHAPTER 9 VENTS SECTION 90 GENERAL run undiminished in size and as directly as possible from the building drain through to the open air above the roof. 90. Scope. The provisions of this chapter shall govern

More information

Summer Works Scheme 2010

Summer Works Scheme 2010 WCMS 01/2009 TO: PRIMARY AND POST PRIMARY SCHOOL AUTHORITIES Summer Works Scheme 2010 Devolved Capital Grants for Water Conservation Measures in Primary and Post Primary School Buildings Guide for School

More information

CHAPTER 9 VENTS SECTION

CHAPTER 9 VENTS SECTION CHAPTER 9 VENTS SECTION 901 GENERAL 901.1 Scope. The provisions of this chapter shall govern the materials, design, construction and installation of vent systems. 901.2 Trap seal protection. The plumbing

More information

CRAFTSMAN EXAMINATION, JUNE 2007 PLUMBING QUESTION AND ANSWER BOOKLET. Time allowed THREE hours

CRAFTSMAN EXAMINATION, JUNE 2007 PLUMBING QUESTION AND ANSWER BOOKLET. Time allowed THREE hours Affix label with Candidate Code Number here. If no label, enter candidate Number if known No. 995 CRAFTSMAN EXAMINATION, JUNE 007 PLUMBING INSTRUCTIONS QUESTION AND ANSWER BOOKLET Time allowed THREE hours

More information

GARCIA GALUSKA DESOUSA Consulting Engineers

GARCIA GALUSKA DESOUSA Consulting Engineers L#58619/Page 1/November 1, 2017 PLUMBING Executive Summary: Presently, the Plumbing Systems serving the building are cold water, hot water, sanitary, waste and vent system, storm drain piping, and natural

More information

Plumbing Guidelines 2012 IBC/ANSI A

Plumbing Guidelines 2012 IBC/ANSI A Plumbing Guidelines 2012 IBC/ANSI A117.1-2009 This document provides basic and fundamental information for accessible plumbing fixtures, toilet rooms and bathing facilities. It is not intended to replace

More information

Repair and Maintenance Manual for Residential Quarters under Licence Agreement

Repair and Maintenance Manual for Residential Quarters under Licence Agreement Repair and Maintenance Manual for Residential Quarters under Licence Agreement Version Issue Date 4.0 (Third Issue) January 2017 CONTENTS Page 1. Introduction 2 2. Conditions for the Provision of Repair

More information

REGISTRATION EXAMINATION, NOVEMBER 2017 TRADESMAN PLUMBER ANSWER SCHEDULE

REGISTRATION EXAMINATION, NOVEMBER 2017 TRADESMAN PLUMBER ANSWER SCHEDULE No. 9192 REGISTRATION EXAMINATION, NOVEMBER 2017 TRADESMAN PLUMBER ANSWER SCHEDULE Plumbers, Gasfitters and Drainlayers Board, 2017. All rights reserved. No part of this publication may be reproduced by

More information

IFO6820. Ifo Sign Junior Toilet S Trap. Product Code. Call

IFO6820. Ifo Sign Junior Toilet S Trap. Product Code. Call When tested in accordance with Standard AS/NZS 6400 For more information and to compare products, refer to: Ifo Sign Junior Toilet S Trap One-piece free standing junior toilet. Suitable for child care

More information

Pipe Sizing Table. Hydraulic Load Served (fixture units)

Pipe Sizing Table. Hydraulic Load Served (fixture units) MODULE 1 INTRODUCTION Notes: A Pipe Type Horizontal branch Pipe Sizing Table Hydraulic Load Served (fixture units) Size (in.) Code Reference 2 + 1.5 = 3.5 2 7.4.9.1.(1) B Soil stack 13.5 + 13.5 = 27 3

More information

Plumbing Guidelines 2015 Minnesota Accessibility Code Based on the 2012 IBC and 2009 ANSI A117.1

Plumbing Guidelines 2015 Minnesota Accessibility Code Based on the 2012 IBC and 2009 ANSI A117.1 Plumbing Guidelines 2015 Minnesota Accessibility Code Based on the 2012 IBC and 2009 ANSI A117.1 This document provides basic and fundamental information for accessible plumbing fixtures, toilet rooms

More information

Pro Vent TM. Provent Systems Inc Capital Circle Lawrenceville Georgia

Pro Vent TM. Provent Systems Inc Capital Circle Lawrenceville Georgia Pro Vent TM Guide to Design and Usage Provent Single System Handling Installation Corrosion Ease Simplicity Resistance IPMO Copyright (c) 2014, Pro Vent Systems Inc., plus *2016 Revisions ll Rights Reserved

More information

Wavin HepvO Self-Sealing Waste Valve

Wavin HepvO Self-Sealing Waste Valve Waste water drainage PRDUCT AND INSTALLATIN MANUAL Wavin Hepv Self-Sealing Waste Valve Introduction to Hepv Hepv is a unique self-sealing waste valve that prevents the escape of foul sewer air from waste

More information

Installation Systems. Safety and durability

Installation Systems. Safety and durability Installation Systems Safety and durability Installation Systems Safety and durability Wide range of solutions Duplo WC Compact With Roca s Duplo systems you obtain all the installation flexibility for

More information

WC-Unit. Assembly instructions I00127_NOV 16

WC-Unit. Assembly instructions I00127_NOV 16 IföSign 6860 WC-Unit 6860 Assembly instructions I00127_NOV 16 A joint government and industry program Licence No. 0058 When tested in accordance with Standard AS/NZS 6400 For more information and to compare

More information

Installation & User Guide

Installation & User Guide Installation & User Guide Dual-Flush Toilet NOTE: If your new toilet pan has Side Entry holes, please ignore this installation guide and refer to document # 1265059-A2. 1102602-A2-J Tools And Materials

More information

AS/NZS :2015. Plumbing and drainage AS/NZS :2015. Part 4: Heated water services. Australian/New Zealand Standard

AS/NZS :2015. Plumbing and drainage AS/NZS :2015. Part 4: Heated water services. Australian/New Zealand Standard AS/NZS 3500.4:2015 Incorporating Amendment No. 1 Australian/New Zealand Standard Plumbing and drainage Part 4: Heated water services Superseding AS/NZS 3500.4:2003 AS/NZS 3500.4:2015 AS/NZS 3500.4:2015

More information

Accreditation Schedule

Accreditation Schedule JOINT ACCREDITATION SYSTEM OF AUSTRALIA AND NEW ZEALAND HELPING MARKETS WORK BETTER AUSTRALIA FECCA House, 4 Phipps Close, Deakin, ACT 2600 PO Box 304, Deakin West, ACT 2605 P: +61 (0)2 6232 2000 NEW ZEALAND

More information

IFO6872. Ifo Sign Toilet Increased Height P Trap AS1428.1:2009. Product Code. Call

IFO6872. Ifo Sign Toilet Increased Height P Trap AS1428.1:2009. Product Code. Call When tested in accordance with Standard AS/NZS 60 For more information and to compare products, refer to: Ifo Sign Toilet Increased Height P Trap AS1428.1:2009 White freestanding toilet suite with 460mm

More information

HUTS SANITATION TANKS, DRUMS & BINS PIPING

HUTS SANITATION TANKS, DRUMS & BINS PIPING Product Information HUTS SANITATION TANKS, DRUMS & BINS PIPING THE KING JOHN The King John Rectangular Hut is ideally suited for events and contractors, for professional teams on construction sites and

More information

DEPARTMENT OF TRADE AND INDUSTRY DEPARTEMENT VAN HANDEL EN NYWERHEID. NATIONAL REGULATOR FOR COMPULSORY SPECIFICATIONS ACT (Act 5 of 2008)

DEPARTMENT OF TRADE AND INDUSTRY DEPARTEMENT VAN HANDEL EN NYWERHEID. NATIONAL REGULATOR FOR COMPULSORY SPECIFICATIONS ACT (Act 5 of 2008) STAATSKOERANT, 19 NOVEMBER 2010 No.33763 11 No. R. 1072 DEPARTMENT OF TRADE AND INDUSTRY DEPARTEMENT VAN HANDEL EN NYWERHEID 19 November 2010 NATIONAL REGULATOR FOR COMPULSORY SPECIFICATIONS ACT (Act 5

More information

doc.m rimless super pack

doc.m rimless super pack 433 APRIL 2013 * * LESS ABLE 12:1:434 doc.m rimless super pack modern rimless design 4 litre flush Doc.M rimless super pack with white grab rails & seat. Right hand installation shown. Doc.M rimless super

More information

ASME STANDARDS IN MODEL CODES

ASME STANDARDS IN MODEL CODES STANDARDS IN MODEL CODES ASME Name Model Code With Year of Referenced IPC IRC UPC 2009 NSPC A112.1.2 Air Gaps in Plumbing 2004 2004 2004 2004 A112.1.3 Air Gap Fittings For Use With Plumbing, Appliances

More information

DOMESTIC & COMMERCIAL PLUMBING SYSTEMS FURTHER INFOMATION

DOMESTIC & COMMERCIAL PLUMBING SYSTEMS FURTHER INFOMATION DOMESTIC & COMMERCIAL PLUMBING SYSTEMS FURTHER INFOMATION Hot and Cold water distribution pipework Sizing of pipework For everyday plumbing in an average sized building a rule of thumb can be used when

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17065:2012

SCOPE OF ACCREDITATION TO ISO/IEC 17065:2012 SCOPE OF ACCREDITATION TO ISO/IEC 17065:2012 TEi-LISTING SERVICES 3455 S. 500 W. Salt Lake City, UT 84115 Mrs. Alona MacGregor (Authorized Representative) Phone: 801 262 1868 Email: alona@tei-test.com

More information

Australian/New Zealand Standard

Australian/New Zealand Standard AS/NZS 3500.4:2003 (Incorporating Amendment Nos 1 and 2) AS/NZS 3500.4:2003 Australian/New Zealand Standard Plumbing and drainage Part 4: Heated water services AS/NZS 3500.4:2003 This Joint Australian/New

More information

PANACHE ORDERING INFORMATION NOTES T01-A INSTALLATION INSTRUCTIONS

PANACHE ORDERING INFORMATION NOTES T01-A INSTALLATION INSTRUCTIONS PANACHE INSTALLATION INSTRUCTIONS VITREOUS CHINA TWO-PIECE TOILET S-TRAP 305mm/P-TRAP 180mm K-18182T/K-18182T-S Please read these instructions carefully to familiarize yourself with the required tools,

More information

RESTROOMS. Proper daily cleaning procedures. Custodial Best Practices

RESTROOMS. Proper daily cleaning procedures. Custodial Best Practices RESTROOMS Proper daily cleaning procedures Custodial Best Practices Cleaning tools Toilet bowl brush stiff bristle brush used for basic scrubbing and cleaning of toilets Toilet bowl swab soft nylon applicator

More information

ProVent Systems Plumbing Fundamentals. Educational Literature. Comparison of ProVent Design Rules and The International Plumbing Code

ProVent Systems Plumbing Fundamentals. Educational Literature. Comparison of ProVent Design Rules and The International Plumbing Code ProVent Systems Plumbing Fundamentals Educational Literature Comparison of ProVent Design Rules and The International Plumbing Code Guide to Contents Topics and Descriptions Page Interior views of the

More information

INSTALLATION AND CARE INSTRUCTIONS

INSTALLATION AND CARE INSTRUCTIONS INSTALLATION AND CARE INSTRUCTIONS THESE INSTRUCTIONS MUST E READ EFORE INSTALLATION IS ATTEMPTED. FAILURE TO DO SO MAY COMPROMISE WARRANTY. FOLLOWING INSTALLATION PLEASE LEAvE ALL PAPERWORK WITH CLIENT

More information

Matrix of changes for the National Standard Plumbing Code July 2013

Matrix of changes for the National Standard Plumbing Code July 2013 Matrix of changes for the National Standard Plumbing Code July 2013 Item # Section Number Person Submitting Change Committee Action 10-77 10.20.8 and Table 3.1.3 XI Certification 10-82 12.16 Size and Lengths

More information

Dissecting Rainwater Pump Energy Use in Urban Households

Dissecting Rainwater Pump Energy Use in Urban Households Dissecting Rainwater Pump Energy Use in Urban Households Tjandraatmadja, G. 1, Pollard, C. 1, Sharma, A. 1 and Gardner, T. 2 1 CSIRO Land and Water, PO Box 56, Highett,Vic 3190 2 CSIRO Land and Water,

More information

CHAPTER 5 Water, Plumbing, and Waste

CHAPTER 5 Water, Plumbing, and Waste CHAPTER 5 Water, Plumbing, and Waste Parts 5-1 Water 5-2 Plumbing System 5-3 Mobile Water Tank 5-4 Sewage, Other Liquid Waste, and Rainwater 5-5 Refuse, Recyclables, and Returnables 5-1 Water 5-101 Source

More information

Restrooms. Proper daily cleaning procedures. Custodial Best Practices

Restrooms. Proper daily cleaning procedures. Custodial Best Practices Restrooms Proper daily cleaning procedures Custodial Best Practices Cleaning tools Bowl brush stiff bristle brush used for basic scrubbing and cleaning of toilets and urinals. Bowl swab soft nylon applicator

More information

Company : DURAVIT POSTFACH 240 WERDERSTRASSE 36 DE-D HORNBERG

Company : DURAVIT POSTFACH 240 WERDERSTRASSE 36 DE-D HORNBERG SANITARY APPLIANCES CSTB attests that the products referred to in the appendix comply with the characteristics described in the certification system NF 017 (revision 26) after evaluation according to the

More information

Karess ORDERING INFORMATION NOTES T01-A INSTALLATION INSTRUCTIONS

Karess ORDERING INFORMATION NOTES T01-A INSTALLATION INSTRUCTIONS Karess INSTALLATION INSTRUCTIONS VITREOUS CHINA TWO-PIECE TOILET S-TRAP 305mm K-5331T-S S-TRAP 400mm K-5471T-S Please read these instructions carefully to familiarize yourself with the required tools,

More information

Mechanical Inspection Plumbing

Mechanical Inspection Plumbing 0811 Fixtures Sinks, drinking fountains, water closets, showers, etc. Classroom Sinks. Classroom sinks (19) are enameled cast iron self rimming side ledge with gooseneck faucet trim with index handles,

More information

AQUA GENIUS AQUA GENIUS. Boiling, chilled, still, sparkling, filtered. Aqua Genius, that's Billi.

AQUA GENIUS AQUA GENIUS. Boiling, chilled, still, sparkling, filtered. Aqua Genius, that's Billi. AQUA GENIUS AQUA GENIUS Boiling, chilled, still, sparkling, filtered. Aqua Genius, that's Billi. www.billi.com.au Water, the elixir of life. Billi brings water back to its purest elemental form. A four

More information

Company : DURAVIT POSTFACH 240 WERDERSTRASSE 36 DE-D HORNBERG

Company : DURAVIT POSTFACH 240 WERDERSTRASSE 36 DE-D HORNBERG SANITARY APPLIANCES CSTB attests that the products referred to in the appendix comply with the characteristics described in the certification system NF 017 (revision 26) after evaluation according to the

More information

APPENDIX L ALTERNATE PLUMBING SYSTEMS

APPENDIX L ALTERNATE PLUMBING SYSTEMS ALTERNATE PLUMBING SYSTEMS L 1.0 General. L 1.1 Applicability. The intent of this appendix is to provide clarification of procedures for the design and approval of engineered plumbing systems, alternate

More information

Mechanical System Description

Mechanical System Description 1. Building Description: Mechanical System Description The building is a Type-1B construction, 9-levels, non-high rise building with 67 affordable family housing units. The first level of the structure

More information

SECTION PLUMBING

SECTION PLUMBING SECTION 22 10 00 PLUMBING PART 1 GENERAL 1.1 WORK INCLUDED A. Furnish all labor, material and equipment necessary for the complete installation of the sanitary sewer system (including soil and vent piping),

More information

ARCHERTM ORDERING INFORMATION NOTES T01-C INSTALLATION INSTRUCTIONS VITREOUS CHINA ONE-PIECE TOILET K-3639T/K-3639T-C

ARCHERTM ORDERING INFORMATION NOTES T01-C INSTALLATION INSTRUCTIONS VITREOUS CHINA ONE-PIECE TOILET K-3639T/K-3639T-C ARCHER TM INSTALLATION INSTRUCTIONS VITREOUS CHINA ONE-PIECE TOILET K-3639T/K-3639T-C Please read these instructions carefully to familiarize yourself with the required tools, materials, and installation

More information

Modular Grease Trap MGTA

Modular Grease Trap MGTA Modular Grease Trap MGTA and MGTA) Installation Requirements Installation Water Requirements Corporation Water Corporation 22 Ethel Ave Brookvale NSW 2100 Postal: PO Box 255 Collaroy NSW 2097 Freecall

More information

ENERGY SA ERS ELECTRIC AND DIGITAL CONTROLLED WATER HEATERS. The most advanced way to make hot water

ENERGY SA ERS ELECTRIC AND DIGITAL CONTROLLED WATER HEATERS. The most advanced way to make hot water ENERGY SA ERS Over 25 years experience manufacturing quality electric water heaters ELECTRIC AND DIGITAL CONTROLLED WATER HEATERS The most advanced way to make hot water ELWA offers a range of electric

More information

3/4.8 AERODYNE 3/4.8L CLASS FIVE+

3/4.8 AERODYNE 3/4.8L CLASS FIVE+ 3/4.8 AERODYNE 3/4.8L CLASS FIVE+ INSTALLATION INSTRUCTIONS VITREOUS CHINA SKIRTED TRAPWAY ONE-PIECE TOILET S-TRAP 305mm K-3869T/K-3869T-S S-TRAP 400mm K-4165T/K-4165T-S Please read these instructions

More information

2006 Thermaco, Inc. All rights reserved Patented/Patents Pending Specifications subject to change without notice

2006 Thermaco, Inc. All rights reserved Patented/Patents Pending Specifications subject to change without notice One to Three Compartment Sink When planning a multiple fixture discharge into a single Big Dipper, establish the size unit required by following the method outlined in the sizing section of this manual.

More information

Gulfport, Mississippi 21 May 2007

Gulfport, Mississippi 21 May 2007 G PLUMBING GENERAL REQUIREMENTS The D-BC shall design the plumbing system to comply with this criteria and the Plumbing Code. Piping shall be shown on the same plan as the fixtures being served. Pipe size

More information

This chapter investigates domestic

This chapter investigates domestic 207 SANITATION This chapter investigates domestic sanitation systems. It looks at the many different sanitary appliances available and the systems of above-ground sanitation pipework that they are connected

More information

There are several designs of toilets. These are close coupled, low level, high level, back to wall, and wall- hung.

There are several designs of toilets. These are close coupled, low level, high level, back to wall, and wall- hung. There are several designs of toilets. These are close coupled, low level, high level, back to wall, and wall- hung. Close coupled is floor mounted with the cistern against the wall and resting on the back

More information

Push Button Electronic Timer. 31VETR Series. Installation Instructions

Push Button Electronic Timer. 31VETR Series. Installation Instructions Push Button Electronic Timer Series Installation Instructions Contents 1.0 Product Range... 3 2.0 Description... 3 3.0 Features... 3 4.0 Important Warnings... 3 5.0 Timer Control... 4 5.1 Push Button Control...

More information

Lincoln Public Schools

Lincoln Public Schools Lincoln Public Schools School Building Committee Meeting February 13, 2019 Today s Agenda 1. Review Updated Site Plan 2. Review and Approve OPR 3. Review MEP Systems 4. Review Progress Energy Model Review

More information

Lecture : Introduction to building services I - Plumbing & Drainage Services 22 September 2016

Lecture : Introduction to building services I - Plumbing & Drainage Services 22 September 2016 SBS4113 Architecture & Buildings http://ibse.hk/sbs4113/ Lecture : Introduction to building services I - Plumbing & Drainage Services 22 September 2016 Guest teacher : Ir. Eur Ing. K P Cheung Faculty of

More information

Company : ECZACIBASI YAPI GERECLERI A.S. BUYUKDERE CAD. No. 185 TR LEVENT-ISTANBUL

Company : ECZACIBASI YAPI GERECLERI A.S. BUYUKDERE CAD. No. 185 TR LEVENT-ISTANBUL SANITARY APPLIANCES CSTB attests that the products referred to in the appendix comply with the characteristics described in the certification system NF 017 (revision 26) after evaluation according to the

More information

Add the luxury of extra facilities almost anywhere you choose

Add the luxury of extra facilities almost anywhere you choose SANIFLO RANGE OF SMALL-BORE SANITARY SYSTEMS Add the luxury of extra facilities almost anywhere you choose Pumps Macerators Inclusive Products see website for latest product updates: Add luxury, add value.

More information

Condensing Heat Exchanger Suitable Gas Fired Ideal GT & GTE boiler ranges

Condensing Heat Exchanger Suitable Gas Fired Ideal GT & GTE boiler ranges Condensing Heat Exchanger Suitable Gas Fired Ideal GT & GTE boiler ranges 2 The new GT Condenser provides higher efficiencies and low running costs from the Ideal range of pressurised gas boilers. Extracting

More information

Approved Basic Trade Waste Pre-treatment Products

Approved Basic Trade Waste Pre-treatment Products Approved Basic Trade Waste Pre-treatment Products Reviewed 05/02/2016 This list shows the basic pre-treatment devices approved by SA Water for connection to its sewerage system. Dischargers may choose

More information

MULTISAN Fully automatic sewage and waste water pump

MULTISAN Fully automatic sewage and waste water pump MULTISAN Fully automatic sewage and waste water pump Multisan is suitable for pumping waste water from toilets, bidets, showers and basins from rooms which are below the sewer level, or conditions where

More information

PLUMBING INSTALLATIONS

PLUMBING INSTALLATIONS PLANNING, PROPERTY AND DEVELOPMENT DEPARTMENT PLUMBING INSTALLATIONS A homeowner guide to plumbing requirements for single-family dwellings November 2017 contents Permit Requirements... 3 Inspection Requirements...

More information

Florida Building Code 5 th Edition (2014) Building. Broward County Edition Loose-leaf Supplement

Florida Building Code 5 th Edition (2014) Building. Broward County Edition Loose-leaf Supplement Board of Rules and Appeals FBC 5 th Edition (2014)- Building - Supplement No. 1 June 30, 2015 Florida Building Code 5 th Edition (2014) Building File removed pages for reference. Broward County Edition

More information

PLUMBING FIXTURES CHAPTER 27

PLUMBING FIXTURES CHAPTER 27 CHAPTER 27 PLUMBING FIXTURES SECTION P2701 FIXTURES, FAUCETS AND FIXTURE FITTINGS P2701.1 Quality of fixtures. Plumbing fixtures, faucets and fixture fittings shall be constructed of approved materials,

More information

Product Catalogue WB Engineering Containers. fast inexpensive safe flexible certified

Product Catalogue WB Engineering Containers. fast inexpensive safe flexible certified Product Catalogue WB Engineering Containers fast inexpensive safe flexible certified Table of Content Product Catalogue Key data WBEC - Standard & Premium Key data WBEC - Standard model Key data WBEC Premium

More information

Sanitary & Hospital Equipment

Sanitary & Hospital Equipment Sanitary & Hospital Equipment Introduction With 40 years experience, M&G Olympic Products has maintained its position as a leading specialist in the design, manufacture and installation of custom built

More information

Company : ECZACIBASI YAPI GERECLERI A.S. BUYUKDERE CAD. No. 185 TR LEVENT-ISTANBUL

Company : ECZACIBASI YAPI GERECLERI A.S. BUYUKDERE CAD. No. 185 TR LEVENT-ISTANBUL SANITARY APPLIANCES CSTB attests that the products referred to in the appendix comply with the characteristics described in the certification system NF 017 (revision 26) after evaluation according to the

More information

This document is a preview generated by EVS

This document is a preview generated by EVS TECHNICAL REPORT RAPPORT TECHNIQUE TECHNISCHER BERICHT CEN/TR 17221 April 2018 ICS 91.140.70 English Version Guidance on the application of CE marking and preparation of Declaration of Performance for

More information

Installation & User Guide

Installation & User Guide Installation & User Guide MILANO Dual-Flush Two Piece Toilet MIRAGE-S MIRAGE-P DOMANI ELITE DELANO-S DELANO-P 1104782-A2-B Tools and Materials Thank You For Choosing Englefield Thank You For Choosing Englefield.

More information

GRUNDFOS SOLOLIFT2 GRUNDFOS SOLOLIFT2 ENGINEERED BY THE WORLD S LEADING PUMP COMPANY FOR PERFORMANCE, RELIABILITY AND EASY FITTING FROM THE OUTSET.

GRUNDFOS SOLOLIFT2 GRUNDFOS SOLOLIFT2 ENGINEERED BY THE WORLD S LEADING PUMP COMPANY FOR PERFORMANCE, RELIABILITY AND EASY FITTING FROM THE OUTSET. GRUNDFOS The Perfect Fit GRUNDFOS ENGINEERED BY THE WORLD S LEADING PUMP COMPANY FOR PERFORMANCE, RELIABILITY AND EASY FITTING FROM THE OUTSET. 800 POINTS INTRODUCTION - GET INTRODUCED TO A NEW GENERATION

More information

Revision th July The Pinnacle Apartments. Standard Specifications and Finishes

Revision th July The Pinnacle Apartments. Standard Specifications and Finishes Revision 4 24 th July 2018 1. Introduction This specification has been prepared to assist Purchasers in their understanding of the overall scheme, and their rights and obligations as Purchasers. 2. Standard

More information

Level I Chapter 1 Worksheet

Level I Chapter 1 Worksheet Chapter 1 Worksheet 1. For applicability requirements of the Plumbing Code, refer to: a. Building Code b. Administration and Enforcement Code c. Plumbing Code d. Residential Code 2. The provisions of the

More information