2.5mm CLEANCLICKER 750 Fiber Optic Cleaner Performance Verification Report OptiTap-Style Connectors
|
|
- Gavin Greene
- 5 years ago
- Views:
Transcription
1 2.5mm CLEANCLICKER 750 Fiber Optic Cleaner Performance Verification Report OptiTap-Style Connectors April
2 STICKLERS 2.5mm CLEANCLICKER 750 Fiber Optic Cleaner Performance Verification Report OptiTap Style Connectors SCOPE: This report documents the Sticklers 2.5mm CLEANCLICKER 750 fiber optic cleaner at removing heavy levels of skin oil, dryer lint, 91% isopropyl alcohol, and ISO Fine Test Dust (aka Arizona Road Dust) from the end faces of OptiTap style connectors on a drop assembly and with the connector loaded in the adapter housing. TEST PROCESS SUMMARY: 1. Capture base image 2. Apply Contamination TEST EQUIPMENT: Viavi Solutions P5000i ferrule scope Viavi Solutions FiberChekPRO software OptiTap style drop and in port adapter TESTING NOTES: 3. Inspect & capture image 4. Single push engagement of the cleaner 5. Inspect & capture image Pass? No Sticklers performance verification testing process requires us to use established industry accepted inspection software set to the pass/fail criteria of. Sticklers used the Viavi FiberCHEK PRO software set to to eliminate human subjectivity in the pass-fail evaluation process. Sticklers applied heavy to sever levels of each test contaminate to simulate a worse case scenario an optical network s connector could be exposed to in the field. Yes 6. Inspect & capture image Page 1
3 Test Inspection Set Up Inspection Software Example TESTING NOTES: The report images provides a high magnification view with a 400X magnification to provide the reader the best view of the connector s contact region. The test was repeated three times for the drop assembly and for the in adapter. Page 2
4 Skin Oil Test Set Up TESTING NOTES: Skin oil was applied by touching the connector end face to the finger tip of the tester. This was done to simulate accidental contact with an installers finger tip during an installation. The in adapter connector was done by touching the drop assembly connector to the tester s finger tip and loading it into the adapter. Page 3
5 Drop with Skin Oil Drop Test 1 Drop Test 2 Drop Test 3 Page 4
6 In Adapter with Skin Oil In Adapter Test 1 In Adapter Test 2 In Adapter Test 3 Page 5
7 Dryer Lint Test Set Up TESTING NOTES: The dryer lint was applied by touching the connector end face to the dryer lint mass. This was done to simulate the type of contamination that would result from wiping a connector on an installers clothing. The dust the accumulates on equipment cooling fans and in HVAC systems is very similar to dryer lint in texture and composition. The in adapter connector was done by touching the drop assembly connector to the dryer lint and loading it into the adapter. Page 5
8 Drop with Dryer Lint Drop Test 1 Drop Test 2 Drop Test 3 Page 6
9 In Adapter with Dryer Lint In Adapter Test 1 In Adapter Test 2 In Adapter Test 3 Page 7
10 ISO A2 Fine Test Dust Test Set Up TESTING NOTES: The ISO A2 Fine Test Dust was applied by touching the connector end face to the a sample of the fine test dust on a optical grade wipe. The ISO A2 dust was selected for our test because is common test dust used by the companies in the air quality and liquid filtration industries.the particles sizes range from 0.97μm up to 176μm. This was done to simulate the type of dust contamination generated in connector wear debris and the fine dust that is the air. The in adapter connector was done by touching the drop assembly connector to the wipe with the fine test dust and loading it into the adapter. Page 8
11 Drop with ISO A2 Fine Test Dust Drop Test 1 Drop Test 2 Drop Test 3 Page 9
12 In Adapter with ISO A2 Fine Test Dust In Adapter Test 1 In Adapter Test 2 In Adapter Test 3 Page 4
13 91% Isopropyl Alcohol Test Set Up TESTING NOTES: The 91% IPA was applied by touching the connector end face to an optical grade wipe that was moistened and allowed to dry. The 91% IPA was selected because alcohol by mature is hygroscopic which means it attracts water molecules. If an installer uses a 99% IPA in a container that is not hermetically sealed, the alcohol will eventually become diluted over time as the moisture from the air is pulled into the container. Alcohol is humid areas will become diluted at faster rate. The 91% IPA was selected to simulate the problems that an installer would have who is using IPA and a paper based wipe in the field. The in adapter connector was done by touching the drop assembly connector to the wipe with the fine test dust and loading it into the adapter. Page 11
14 Drop with 91% Isopropyl Alcohol Drop Test 1 Drop Test 2 Drop Test 3 Page 12
15 In Adapter with 91% Isopropyl Alcohol In Adapter Test 1 In Adapter Test 2 In Adapter Test 3 Page 13
MOST EFFECTIVE METHOD FOR WIPING A FIBRE
MOST EFFECTIVE METHOD FOR WIPING A FIBRE Step 1: Pull & fold a new wipe Step 2: Apply the cleaning fluid Step 3: Wipe the fiber in single direction Avoid oversaturating the wipe Insert the fiber into the
More informationAGENDA Contamination Working with Optical Grade Wipes Sticks & Clickers Optical Grade Fluids & Dusters Best Practices Wrap Up AGENDA Contamination Working with Optical Grade Wipes Sticks & Clickers Optical
More informationApplications Engineering Notes
Applications Engineering Notes Document Title Document Number Revision Number Product Specification and Qualification Test Report: IBC Brand Fiber Optic Connector Cleaner MT38 II AEN-1146 Issue Effective
More informationThe True Value of Connector Inspection: New Challenges and Best Practices
The True Value of Connector Inspection: New Challenges and Best Practices Vincent Racine Product Line Manager August 2011 1 Table of contents 1 Best Practices 2 Connector Inspection Tools 3 Connector Inspection
More informationSources of End Face Contamination on Fiber Optical Interconnects and Recommended Best Practices for Removing the Contaminates
Sources of End Face Contamination on Fiber Optical Interconnects and Recommended Best Practices for Removing the Contaminates Brian Teague Product Line Manager 18 November 2016 Program Agenda 1. Do It
More informationDevelopment of a dry fabric cleaner for miniature parallel optical interface PRIZM LightTurn connector
Development of a dry fabric cleaner for miniature parallel optical interface PRIZM LightTurn connector March 7, 2011 Toshiaki Satake, Brian Teague, Jillcha Wakjira, Alan Ugolini and Darrell Childers US
More informationCleaning a Fibre Optic Solution
Before any testing of a Fibre Optic Solution can commence, there are up to 3 steps that need to be completed. Step 1 Inspect the Fibre Connectors for damage, dirt or any other foreign residue that will
More informationINDUSTRY STATS SNAPSHOT
INDUSTRY STATS SNAPSHOT HTI Martin Technical Research Survey of 89 network owners and network contactors study on network failure. 98% of Network Contractors experienced fiber failures during the installation
More informationWhite Paper Fiber optic connections: check and clean first, then connect!
White Paper Fiber optic connections: check and clean first, then connect! How installers ensure the quality of their work Fiber optic connections: check and clean first, then connect! How installers ensure
More informationWhite Paper: Fiber Contamination, Cleaning and Inspection. Introduction.
White Paper: Fiber Contamination, Cleaning and Inspection. Introduction. Despite industry best practice of inspecting and cleaning fiber optic endfaces, contaminated connections remain the number one cause
More informationConnector Maintenance
Connector Maintenance Jean-François Lavoie, Product Manager, Industrial and Scientific Division Connectors are designed to require minimum maintenance in order to provide reliable operation for many years.
More informationMulti fiber connector: Visual inspection and cleaning guide
Multi fiber connector: HUBER+SUHNER AG Fiber Optics FOBUFiber connectivity Indoor FCI DOC-0000761071 Date: 26 August 2016 Page 1 of 8 TABLE OF CONTENTS GENERAL INFORMATION 2 VISUAL INSPECTION 3 MICROSCOPE
More informationBest Practice Briefing
Best Practice Briefing Fiber Optic Connector Handling, Inspection, andcleaning microwave photonic systems Expand Your RF Horizons Briefing Overview Personnel Safety & Best Practices Insertion Loss (IL)
More informationApplications Engineering Notes
Applications Engineering Notes Document Title Document Number US Conec Recommended Cleaning Procedure for Multifiber and Single Fiber Connectors and Mating Adapters AEN-1902 Revision Number 2.0 Effective
More informationFiber Optic Connector Cleaning and Inspection Kit Instructions
Instruction Sheet 860376037 Rev E, March 2018 Fiber Optic Connector Cleaning and Inspection Kit Instructions General This instruction sheet describes the use of the CommScope Fiber Optic Connector Cleaning
More informationFiber Optic Connector Cleaning Solutions
Fiber Optic Connector Cleaning Solutions www.usconec.com Table of Contents Fiber Optic Cleaning Guide The Importance of Cleaning 3 Good Cleaning Practices 3 Single Fiber Cleaner Instructions 4 Multi-fiber
More informationWhite Paper: Standard-Compliant Certification & Best Practices Ensure Fiber End-face Cleanliness to Eliminate the #1 Cause of Fiber Failure
White Paper: Standard-Compliant Certification & Best Practices Ensure Fiber End-face Cleanliness to Eliminate the #1 Cause of Fiber Failure White Paper: Standard-Compliant Certification & Best Practices
More informationFTTc Network Testing Overview
FTTc Network Testing Overview MTS2K-FTTX-OTDR-BV OLP-87-FTTC-BV MTS-101 KIT w Optitip & Optitap Tips 72C 71M MTS2K-FTTX-OTDR-BV Testing the Fibre Network THE OTDR that can be used on the Local Fibre Network
More informationFIBER OPTIC CONNECTOR CLEANERS
FIBER OPTIC CONNECTOR CLEANERS FIBER OPTIC CONNECTOR CLEANERS TABLE OF CONTENTS Introduction Fiber Optic Connector Cleaning Tools Page 2 Single Fiber Cleaning Tools NEOCLEAN E Refillable Cleaners IBC Brand
More informationCleaning of fiber optic connectors
Cleaning of fiber optic connectors HUBER+SUHNER AG Fiber Optics DOC-0000415541 March 2018 Page 1 of 20 Table of contents 1. General guidelines... 2 2. Cleaning of ODC connectors... 4 3. Cleaning of Q-ODC-12
More informationFIBER OPTIC CLEANING AND INSPECTION. Dry Cleaning Wet Cleaning Connector Cleaning Kits Inspection Systems
FIBER OPTIC CLEANING AND INSPECTION One-Click Cleaners U.S. Patent Numbers 7,212,719 and 8,087,118 The One-Click Cleaner features an easy one push action, which quickly and effectively cleans the end-face
More informationfi-4530c & fi-5530c CONSUMABLE REPLACEMENT
fi-4530c & fi-5530c CONSUMABLE REPLACEMENT AND CLEANING INSTRUCTIONS CG00000-718301 Revision C1 KIT CONTENTS Pick Roller Qty 2 Pad Assembly Qty 5 F1 Cleaner Isopropyl Alcohol Qty 1 Cotton Swabs Qty 1 100/pack
More informationReflectance, The Hidden Danger That Increases Bit Error Rates in Your Fiber Networks Denver, May 22nd, 2010
Reflectance, The Hidden Danger That Increases Bit Error Rates in Your Fiber Networks Denver, May 22nd, 2010 Adrian Young Sr. Customer Support Engineer Foreword Reflectance is measured using an Optical
More informationThe Seven Deadly Sins of Fiber Optics By Sean Sheedy, Fiber Optic Specialist
The Seven Deadly Sins of Fiber Optics By Sean Sheedy, Fiber Optic Specialist First published in Outside Plant Magazine, October 2015 Does anybody in this totally digital, selfie-taking, Facebook-posting
More informationThe Importance of Properly Cleaning Fiber During Splicing
The Importance of Properly Cleaning Fiber During Splicing By Sean Sheedy, Fiber Optic Specialist Using a medium only slightly larger than a human hair, fiber optic communications has transformed our world.
More informationRLH Industries, Inc. Cleaning and Testing Fiber Optic Cable. Reference Guide MD A 0507
RLH Industries, Inc. Cleaning and Testing Fiber Optic Cable Reference Guide MD-019 2014A 0507 RLH Industries, Inc. Copyright 2013 RLH Industries, Inc. All rights reserved. No part of this document may
More informationTitel (auf Masterfolie editierbar) Cleaning of Fiber Connectors
Cleaning of Fiber Connectors 1 Cleaning of fiber connectors Contents: List of materials Cleaning of the connector surface with a cloth How to use a cleaning cassette How to use an In-Ferrule Cleaner Cleaning
More informationISO AIR FILTERS FOR GENERAL VENTILATION: DETERMINING FRACTIONAL EFFICIENCY
ISO 16890-2 AIR FILTERS FOR GENERAL VENTILATION: DETERMINING FRACTIONAL EFFICIENCY APPLICATION NOTE AFT-005 (US) Contents Introduction to ISO 16890... 1 How ISO 16890 Compares to EN 779 and ASHRAE 52.2...
More informationMassachusetts Institute of Technology Kavli Institute for Astrophysics and Space Research (MKI)
Rev ECO Description Author Approved Date A 37-428 Initial Release M Gabutti RFGoeke 10/19/2016 D Riley Massachusetts Institute of Technology Kavli Institute for Astrophysics and Space Research (MKI) Precision
More informationfi-4110cu/m3091/m3092 SERIES CONSUMABLE REPLACEMENT
fi-4110cu/m3091/m3092 SERIES CONSUMABLE REPLACEMENT AND CLEANING INSTRUCTIONS CG00002-003401 Revision A1 KIT CONTENTS Guide Assembly Qty 1 Pad Assembly Qty 3 F1 Cleaner Isopropyl Alcohol Qty 1 Cotton Swabs
More informationOWL. Laser OWL Series. Operations Guide. Singlemode Light Sources. Optical Wavelength Laboratories. Date: October 1, 2015
Laser OWL Series Operations Guide Singlemode Light Sources OWL Optical Wavelength Laboratories Operations Guide Laser OWL and Laser OWL HP Singlemode Light Sources Date: October 1, 015 Version.5 Optical
More informationContemporary Considerations When Precision Cleaning Fiber Optic Connections
Contemporary Considerations When Precision Cleaning Fiber Optic Connections ITW Chemtronics Fiber Optic Products 8125 Cobb Center Drive Kennesaw, GA. 30152 USA 800-645-5244 ext: 213 www.chemtronics.com
More informationA Quick Start Guide to Fiber-to-the-Antenna (FTTA) Installation and Maintenance Testing. Vol. 2 Tier 2 Certification
A Quick Start Guide to Fiber-to-the-Antenna (FTTA) Installation and Maintenance Testing Vol. 2 Tier 2 Certification Notice Copyright Every effort was made to ensure that the information in this document
More informationCleaning Instructions for Symbol IP54 Devices
Cleaning Instructions for Symbol IP54 Devices Purpose: The purpose of this document is to demonstrate the proper methods and solutions to clean Symbol mobile computer IP54 devices as well as their respective
More informationWhen you need perfectly clean splices & connectors. Sticklers Fiber Optic Cleaners
When you need perfectly clean splices & connectors Sticklers Cleaners Cleaning Fluids & Sprays Sticklers Splice & Connector Cleaner Cleaning Fluid Improves the cleaning efficiency of wipes, swabs and cleaning
More informationCleaning Kit Instructions - DTC550 Printer
Cleaning Cleaning Kit Instructions - DTC550 Printer Introduction The special cleaning supplies contained in this Cleaning Kit includes recommended cleaning procedures for the DTC550 printer. Supplies Included
More informationBe Mr. Clean! Using Fluids Other than Alcohol When Cleaning Fiber Optic Connectors. By Mike Jones, MicroCare Corp.
Be Mr. Clean! Using Fluids Other than Alcohol When Cleaning Fiber Optic Connectors By Mike Jones, MicroCare Corp. First published in OSP Magazine, Sept 2015 Long ago in days of yore, like the 1970s, Bell
More informationThe FTA-02 Fiber Arranger
The FTA-02 Fiber Arranger Guide To Operation Sumitomo Electric Lightwave Corp. 78 Alexander Drive Research Triangle Park, NC 27709 Telephone: (919) 541-8100 Toll Free: (800) 358-7378 www.sumitomoelectric.com
More informationMaintenance. Maintenance
Maintenance This section includes: "Adding Ink" on page 7-32 "Emptying the Waste Tray" on page 7-36 "Replacing the Maintenance Kit" on page 7-39 "Cleaning the Paper Release Blade" on page 7-41 "Cleaning
More informationSYSTIMAX 360 Low-Profile, Stackable Splice Tray Kit Instructions
Instruction Sheet 860506468 Issue 2, December 2012 SYSTIMAX Solutions SYSTIMAX 360 Low-Profile, Stackable Splice Tray Kit Instructions General The SYSTIMAX 360 LP-STACK-SPT stackable splice tray is 14
More informationA Quick Start Guide to Fiber-to-theAntenna (FTTA) Installation and Maintenance Testing. Vol. 2 Tier 2 Certification
A Quick Start Guide to Fiber-to-theAntenna (FTTA) Installation and Maintenance Testing Vol. 2 Tier 2 Certification A Quick Start Guide to Fiber-to-the-Antenna enna (FTTA) Installation and Maintenance Testing
More informationUV100E Ultraviolet Air Treatment System
UV100E Ultraviolet Air Treatment System OWNER S GUIDE U.S. Registered Trademark Copyright 2001 Honeywell Inc. All Rights Reserved 69-1442- 1 HOW YOUR ULTRAVIOLET AIR TREATMENT SYSTEM WORKS When installed
More informationFiber Optic Cleaners When you need perfectly clean splices & connectors
USA 09 Fiber Optic Cleaners When you need perfectly clean splices & connectors Cleaning Fluids & Sprays Sticklers Fiber Optic Splice & Connector Cleaner Cleaning Fluid Improves the cleaning efficiency
More informationOF-500 OptiFiber. Advanced Test Equipment Rentals ATEC (2832) Users Manual. Certifying OTDR
Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) OF-500 OptiFiber Certifying OTDR Users Manual PN 1779484 September 2002, Rev. 4 6/06 2002-2006 Fluke Corporation. All
More informationCleaning the internal optics surfaces
Cleaning the internal optics surfaces The face of the fiber-optic assembly and the lens are directly exposed to sample fluids inside the analyzer s flow cell. Automatic rinse cycles use high-pressure rinse
More informationEnsuring Cabling Performance in the Customer-Owned Outside Plant
Ensuring Cabling Performance in the Customer-Owned Outside Plant Needs to be able to qualify the installation to validate bandwidth requirements are met Future high bandwidth applications Future Proof
More informationEnsuring Cabling Performance in the Customer-Owned Outside Plant. Keith Foord Product Manager Greenlee Communications
Ensuring Cabling Performance in the Customer-Owned Outside Plant Keith Foord Product Manager Greenlee Communications Introduction: Outside plant fiber networks require low reflectance terminations for
More informationAccelerating NBN fiber testing. Tom Ronan Marketing Lead Fiber Optics Melbourne
Accelerating NBN fiber testing and workforce Performance. Tom Ronan Marketing Lead Fiber Optics Melbourne Agenda Network Elements and Parameters Distributed Fiber Network (DFN) Construction Network Activation
More informationStandard Test Method for the Evaluation of Texture Appearance Retention of Carpets for Minimum Carpet Standards Program 1. Scope
Standard Test Method for the Evaluation of Texture Appearance Retention of Carpets for Minimum Carpet Standards Program 1. Scope 1.1 This practice describes the equipment and operation of the hexapod tumble
More informationfi-4340c CONSUMABLE REPLACEMENT
fi-4340c CONSUMABLE REPLACEMENT AND CLEANING INSTRUCTIONS CG00000-670601 Revision B1 KIT CONTENTS Pad Assembly Qty 3 Pick Rollers Qty 2 F1 Cleaner Isopropyl Alcohol Qty 1 Cleaning Paper Qty 1 10 / pack
More information3M Crimplok + Connector 8700-UPC & APC SM SC 900 µm
3M Crimplok + Connector 8700-UPC & APC SM SC 900 µm Instructions February 2012 3 78-0013-1746-6-B Safety Precautions Protective Eyewear c CAUTION Safety glasses should be worn when handling chemicals and
More informationAttendance Sheet. (List each model reviewed during this session) Print Name Signature Title. Print Name Signature Title.
THIS CHECKLIST IS DESIGNED FOR USE SOLELY AS A CUSTOMER EDUCATIONAL TOOL, AND IS NOT INTENDED TO REPLACE OR ANY WAY MODIFY THE OLYMPUS INSTRUCTION MANUAL/REPROCESSING MANUAL. BE SURE TO FOLLOW THE DETAILED
More informationFTBx-740C-DWC TUNABLE OTDR C-BAND DWDM METRO ETHERNET LINK CHARACTERIZATION
C-BAND DWDM METRO ETHERNET LINK CHARACTERIZATION GLOBAL PORTABLE FIBER OPTIC TEST EQUIPMENT MARKET LEADERSHIP AWARD NEW OTDR GENERATION Tunable DWDM OTDR for testing through MUX/DEMUX channels to provide
More informationON TRACK Reprocessing In-service / Competency for CF/PCF/GIF Endoscopes (EVIS, EXERA, EXERA II)
THIS CHECKLIST IS DESIGNED FOR USE SOLELY AS A CUSTOMER EDUCATIONAL TOOL, AND IS NOT INTENDED TO REPLACE OR ANY WAY MODIFY THE OLYMPUS INSTRUCTION MANUAL/REPROCESSING MANUAL. BE SURE TO FOLLOW THE DETAILED
More informationHydraulic Reservoir Made of Polymer (TMP) or Steel (TMS)
Electric Drives and Controls Hydraulics inear Motion and Assembly Technologies Pneumatics Service Hydraulic Reservoir Made of Polymer (TMP) or Steel (TMS) RE 9571/0.11 1/1 Replaces: 0.09 Data sheet Hydraulic
More informationGR-326-CORE Singlemode Optical Connectors and Jumper Assemblies
Preface...Preface 1 1. Introduction... 1 1 1.1 Purpose and Scope... 1 1 1.2 Target Audience... 1 2 1.3 Structure and Use of This Document...1 2 1.4 Changes from Issue 2 of GR-326-CORE... 1 3 1.5 Requirements
More informationM210 Multifunction Micro OTDR
Test, Troubleshoot and Document Single-mode and Multimode Fiber Networks Features 30 db dynamic range single-mode 16-hour battery life Remote display capable Touch and Test intuitive user interface New
More informationM210 Multifunction Micro OTDR
Test, Troubleshoot and Document Single-mode and Multimode Fiber Networks Features 30 db dynamic range single-mode 16-hour battery life Remote display capable Touch and Test intuitive user interface New
More informationACCESS Master MT9085 Series. Product Introduction
ACCESS Master MT9085 Series Product Introduction Strengthen of MT9085 Series: 1/5 All Optical Fiber Evaluation Functions in One Tester The ACCESS Master MT9085 series is an all-inone tester with OTDR,
More informationSuits SC, ST & FC 2.5mm PC & APC polish 525+ uses. Suits HFOCs in Optitip systems and other FTTx applications
Fibre Optic Cleaning & Consumables Fibre optic cleaning is one of the most basic, important and often overlooked procedures for maintaining fibre optic networks. FOS offers a comprehensive selection of
More informationCree XLamp CM Family LEDs
soldering & handling CLD-AP240 Rev 1 Cree XLamp CM Family LEDs Introduction Table of Contents www.cree.com/xlamp This application note applies to XLamp CM family LEDs, which have order codes in the following
More informationPrinter Startup and Demo Build The purpose of this section is to execute the following:
Printer Startup and Demo Build The purpose of this section is to execute the following: Power the printer on. Installing new material cartridge. Removing material cartridges. Procedure to empty waste bag.
More informationOTDR II. Tier-2 Optical Time Domain Reflectometer for Multimode and Single-mode Fiber Cabling
Tier-2 Optical Time Domain Reflectometer for Multimode and Single-mode Fiber Cabling Tier-2 Optical Time Domain Reflectometer for Multimode and Single-mode Fiber Cabling The OTDR II is the first tablet
More informationWhich Refrigerant Analyzer do I have? Ultima ID Model RI-2004HV Series
Which Refrigerant Analyzer do I have? 1. Neutronics has manufactured many different Refrigerant Analyzers over the past 25 years. They manufacture these analyzers as Neutronics branded products and also
More informationFOREWORD. Only 3 connector parts makes the assembly process both simple and efficient. CONTENTS. 1. Preparation and tools required for assembly
FOREWORD Thank you for purchasing FOCI s pre-assembled QF and QP (FC/APC) Optical Fiber Connectors. We are confident that our excellent manufacturing procedures and stringent quality control guarantee
More informationAdministration of AMBISOME Using the GemStar Pump
1 1-800-862-2731 Administration of AMBISOME Using the GemStar Pump Drug Name: Volume and Rate: Schedule: FLUSHING: Dextrose Ambisome Dextrose Heparin KEY POINTS: 1. Always wash your hands with an antibacterial
More informationModel 3300 Technical Support and Installation Manual
Model 3300 Technical Support and Installation Manual Manual # T15011 Document Revision: A1 1. OVERVIEW 1 2. BASIC OPERATION 1 2.1 General 1 2.2 Field-of-View 2 2.3 Range 2 2.4 Environment 2 2.5 Configuration
More informationAdsorption Air Dryers
Adsorption Air Dryers ADS 1 to 215 Clean and dry air. Prevent the risks, enjoy the benefits. AVAILABILITY PARTNERSHIP SERVICEABILITY TECHNOLOGY YOU CAN TRUST RELIABILITY SIMPLICITY AVAILABILITY PARTNERSHIP
More informationInstructions for Use: Fiberscope and LED Light Source
Instructions for Use: and Brand Name of Product Generic Name of Product Product Code Number(s) Intended Use Range of Applications for Product Key Specifications of Product, FBR-001, FBR-002, FBR-ULB-100,
More informationE-PDD Duct Smoke Detector Installation Sheet
E-PDD Duct Smoke Installation Sheet E-PDD operation The duct smoke detector's primary purpose is to provide early warning of an impending fire and shut down the HVAC unit in order to prevent smoke from
More informationRust, corrosion and leakages threaten even the best network. Only Quality Air Solutions. in optimal shape. air distribution
Rust, corrosion and leakages threaten even the best distribution network Only Quality Air Solutions keep your air distribution in optimal shape Improve your business productivity, Why? Customer benefits
More informationPET Drying Technology
PET Drying Technology Introduction Industry s increasing demand for clean, reliable sources of high pressure compressed air require that system designers become more educated in dehydration and filtration
More informationWhat is an Integrated Detector Assembly? Aron Traylor. College of Optical Sciences The University of Arizona 29 November 2010.
What is an Integrated Detector Assembly? Aron Traylor College of Optical Sciences The University of Arizona 29 November 2010 Traylor 1 Various IDA s Traylor 2 Why are they used? Integrated Detector Assemblies
More informationFibre Specification Standards
Fibre Specification Standards User Manual The most important thing we build is trust Cobham Wireless - Coverage Table of Contents 1. Single-mode Fibre to ITU-T Recommendation G.652 3 2. SC/APC Mated Pair
More informationAir Cleaning System USE & CARE INSTRUCTIONS. Refurbished
USE & CARE INSTRUCTIONS Guardian Technologies LLC 26251 Bluestone Blvd. Euclid, Ohio 44132 1.866.603.5900 www.guardiantechnologies.com 20015 Guardian Technologies LLC Refurbished Air Cleaning System Model
More informationThe Rise of Tier 2 Testing
The Rise of Tier 2 Testing Why enterprises today demand better visibility into their fiber infrastructure Unprecedented demand for more bandwidth, faster network speeds, lower latency, and improved data
More informationAE2200 FTTx Multi-Function Meter
AE2200 FTTx Multi-Function Meter Key Benefits Future-proof, all-in-one solution includes optical, cable TV analysis, and metallic testing for verifying the installation of FTTx, RFoG and RF PON networks
More informationSELF-ADHESIVE FILM INSTALLATION GUIDE
SELF-ADHESIVE FILM INSTALLATION GUIDE Table of Contents Important Information... 2 Tools & Materials Required... 3 Installation Procedure... 5 Part 1: Preparing the Smart FILM... 5 Part 2: Clean the Glass
More informationCore Alignment All In One Fusion Splicer
Economical Solution for Integrated Fiber Preparation Tool Demand. Core Alignment All In One Fusion Splicer Single Optical Fiber Fusion Splicer US Patent /9 2,09 The Revolution of a Splicer Integrated to
More informationAdsorption Compressed Air Dryer Heatless or heater regeneration
Adsorption Compressed Air Dryer Heatless or heater regeneration What s adsorption? Drying with high efficiency and economy Some compressed air applications requests a low moisture level (dew point between
More informationRefrigerated Air Dryers
Refrigerated Air Dryers Dual Control and Demand Manager Series 600-3000 scfm Energy Saving Refrigerated Dryers A Choice of Two Because compressed air demand fluctuates in some applications and is relatively
More informationDaily Cleaning Instructions: KL1Plus
Daily Cleaning Instructions: KL1Plus Choose Your Model Clear Top Funnel P. 2-3 Gray Top Funnel P. 4-5 Daily Cleaning Instructions: KL1Plus (Clear Top Funnel) Clean the following components at least once
More informationArizona State University NanoFab PARYLENE COATER. Rev D
Arizona State University NanoFab PARYLENE COATER Rev D Table of Contents Contents Table of Contents... 1 1. Purpose / Scope... 2 2. Reference Documents... 2 3. Equipment / Supplies / Material... 2 4. Safety...
More informationCritical Environment Ionizing Blower. Model 5810i. User s Manual
Critical Environment Ionizing Blower Model 5810i User s Manual About ION Systems ION Systems develops, manufactures, and markets system solutions to manage electrostatic charge. As the world's largest
More informationSECTION TESTING OF FIBER OPTIC CABLES
SECTION 27 08 23 TESTING OF FIBER OPTIC CABLES PART 1 GENERAL 1.01 DESCRIPTION A. The work covered by this section of the Specifications includes all labor necessary to perform and complete such construction,
More informationClean! Clean working by Qdel. Qdel laminating supplies Hamburgstraat 9 NL-7575 EG Oldenzaal T: E: I :
Clean! 2014/06 Content Word of advice 3 1. Gloves 4 1a. Latex 4 1b. Nylon 5 2. Clothing 6 2a. Anti static dust coat 6 2b. Hairnet 7 3. Tools 8 3a. Polish cleaning cloth 8 3b. Dust free roller 9 3c. Paper
More informationFerrous debris monitoring. Ferrous debris in oil
Ferrous debris monitoring Cause and Effect What causes metallic debris? Bearings Inadequate Lubrication 34.4% Contamination 19.6% Installation Errors 17.7% Overload 6.9% Storage & Handling Errors 2.8%
More informationDecon Scrubber Owner s Manual
Decon Scrubber Owner s Manual Serial # TM REV0001111209 TABLE OF CONTENTS Warning 1 Operating the Decon Scrubber 2 System Placement 4 Caring for your Decon Scrubber 5 Cleaning Instructions 6 Optic Replacement
More informationKeysight Cleaning Procedures for Lightwave Test and Measurement Equipment
Keysight Cleaning Procedures for Lightwave Test and Measurement Equipment Pocket Guide Notices This document contains proprietary information which is protected by copyright. All rights are reserved.
More informationISO Acceptance tests for Nd:YAG laser beam welding machines Machines with optical fibre delivery Laser assembly
INTERNATIONAL STANDARD ISO 22827-1 First edition 2005-10-15 Acceptance tests for Nd:YAG laser beam welding machines Machines with optical fibre delivery Part 1: Laser assembly Essais de réception pour
More informationWilcom. Model FR2 Fiber Ranger Optical Fault Locator OPERATING INSTRUCTIONS
Wilcom Model FR2 Fiber Ranger Optical Fault Locator OPERATING INSTRUCTIONS Model FR2 Operating Instructions 812-655-002 January, 2002 Copyright (c) 1999 Wilcom All Rights reserved Wilcom reserves the right
More informationEXECUTING HIGHLY ACCURATE FIBER MEASUREMENTS IN A FRACTION OF THE TIME
10 /0 /100Gb/s transmission links are typically shared by a vast number of application and users. EXECUTING HIGHLY ACCURATE FIBER MEASUREMENTS IN A FRACTION OF THE TIME Claiming that they are most of the
More informationM-Series Compact OTDRs User s Guide
M-Series Compact OTDRs User s Guide Limited Warranty One Year Limited Warranty All Noyes products are warranted against defective material and workmanship for a period of one year from the date of shipment
More informationInstruction Manual. IT20K, IT100, IT300 and IT800 Inlet Traps. A Issue F. ITC800 Inlet Chemical Trap. ITD20K Inlet Desiccant Trap
Instruction Manual A441-01-880 Issue F IT20K, IT100, IT300 and IT800 Inlet Traps Description ITO20K Inlet Catchpot ITC20K Inlet Chemical Trap ITD20K Inlet Desiccant Trap ITF20K Inlet Dust Filter ITO100
More informationON THE BUTTON A reference guide to environmental ratings used for push button enclosures
ON THE BUTTON A reference guide to environmental ratings used for push button enclosures A REFERENCE GUIDE TO KEY TOPICS IN PUSH BUTTON SELECTION AND SAFETY CONTENTS I. INTRODUCTION...............................
More informationManual Pre-disinfection/Cleaning and Sterilization Instructions for SATELEC wrenches
Caution Manual Pre-disinfection/Cleaning and Sterilization Instructions for SATELEC wrenches Do not use steel wool or abrasive cleaners. Avoid solutions containing iodine or with a high chlorine content.
More informationT E C H T A L K G L A S S S T A I N I N G
T E C H T A L K GLASS STAINING GLASS STAINING This Tech Talk provides you with important information on the causes of glass staining, and how to prevent it from occurring during construction and storage.
More informationFTB-7400E Metro/CWDM OTDR METRO/CORE AND CWDM NETWORK FIBER CHARACTERIZATION
METRO/CORE AND CWDM NETWORK FIBER CHARACTERIZATION i OLM R E A D Y GLOBAL PORTABLE FIBER OPTIC TEST EQUIPMENT MARKET LEADERSHIP AWARD High-resolution OTDR covering longer metro distances and ITU-based
More informationFTB/FTBx-740C-CWDM Tunable OTDR 18-WAVELENGTH CWDM OTDR FOR METRO ETHERNET AND C-RAN LINK CHARACTERIZATION
18-WAVELENGTH CWDM OTDR FOR METRO ETHERNET AND C-RAN LINK CHARACTERIZATION NEW OTDR GENERATION A single and compact OTDR unit that covers all 18 CWDM ITU channels for testing through MUX/DEMUX channels,
More informationTechnical Publication
Technical Publication Installation Guidelines - HELIAX FiberFeed Solutions for RRH Systems Fiber/Copper Cables: RFF-16SM-812-APE RFF-16SM-810-APE RFF-16SM-808-APE Related Support and Learning Opportunities
More information