2 Who are We and what do we do? Established in 2012, Force-Dry, operate a hire fleet of Temporary site boilers to link onto underfloor heating loops laid within flowing liquid floor screeds to accelerate the drying process whilst at the same time providing the commissioning process as per the British standard BS8204 part 7-Pumpable self smoothing screeds code of practice. Working within the residential, leisure and commercial sectors driving quality assurance systems and reducing floor failures for main contractors and their clients
3 Why use Force-Dry? 50mm Screed natural drying time with good weather conditions = 60days minimum. However, with typical UK Weather up to days Using Force-Dry boilers starting on day 7 following the pour = 21days with good environmental controls in place Gain Valuable Programme time Reduce the risk of floor failure and expensive remedial costs Drive quality assurance M&E Commissioning opportunities Background heat for follow on trades
4 The rise of liquid screeds Quicker to install with thinner screed depths up to 2000m2 per day Faster heat up times via superior encapsulation and heat transfer when in operation Reduced carbon footprint Reduced Weight loading on buildings
5 Quality Control Flow Test??? Simple flow test using a calibrated cylinder or flow cone on a flat scaled board which can be measured and checked against the manufacturers specification Photograph using smartphone and add to OEM Manual
6 Control & Manage the Environment! Control of the environment is critical to the drying process of any floor screed whether drying naturally or when Force-Drying, with the typical constraints found on site and poor environmental control measures dying rarely succeeds in the allotted programme time, resulting in possible floor failure. Good Practice; Avoid draughts across a newly laid screed Seal up openings including ceiling voids, close wherever possible, all doors and windows. Install a temporary seal if required. Day 4 Install and operate dehumidifiers and manage them well. Day 7 Remove laitance by sanding floors and introduce Force-Dry Boilers. Only test the moisture content of the floor in a controlled environment and consider the method of testing.
7 Moisture measurement! Tramex Protometer Carbide Bomb Testing Kit Hair Hygrometer Testing Kit
8 The Force-Dry objectives Promote a controlled drying process in line with British Standards* Improve Quality systems of Main Contractors & all stakeholders Reduce floor failure& expensive remediation Gain valuable programme time Reduce Latent Defects
9 The Force Drying Process-Best Practice Day 1 When the screed arrives, carry out the slump test prior to the pour, record result via photo, carry out the Pour, ensure the area is protected from rapid drying / draughts for the first hours, Light foot traffic only after 48hours. Day 4-5 Introduce Dehumidifiers & ensure they are emptied regularly, consider drip tray under catchment tank. Ensure doors frames and ceilings are all sealed to aid the process. Failure to do so will prolong the drying time Day 6 Carry out Moisture test to establish the relative humidity 0-100% & record results Measure using - Air Hygrometer, Tramex meter, Protometer, Carbide Bomb Test(destructive method) Day 7 Sand floors to remove laitance (delaying this process could result in diamond grinding the surface as the laitance hardens over time) Introduce Force Dry Boilers at 20 degrees (or the lowest manifold temperature) Important! Manage Dehumidifiers Ensure doors frames and ceilings are all sealed to aid the process. Failure to do so will prolong the drying time. Check dehumidifiers and empty catchment tank regularly.
10 The Force Drying Process-Best Practice Day 8-13 Increase the boiler temperature by 5 deg per 24hr period until 50 degrees is reached then Hold temperature for 7 days. Day For 40-50mm screed, maintain 50 degrees for 7 days. NOTE- For screeds over 50mm thick e.g. 75mm hold for 14 days. Day Reduce boiler temperature by 5 degrees per day down to 20 degrees. Carry out moisture test prior to disconnecting boiler. If RH <75% is not achieved continue drying process. Day Maintain dehumidifiers and carry out final moisture test, Aim for relative humidity of 75% or less before applying floor coverings. Follow screed Manufacturers instructions for suitable surface sealer / primer.
11 Remember; Removal of laitance, Good ventilation using Dehumidifiers and Force-Drying is critical to the drying/commissioning process which can be achieved in under 28 days for a 50mm screed. Open doors and windows, spaces that are not enclosed will delay the drying process. Moisture ingress Water ingress, Spillages & Using water to damp down will delay the drying process. Consider Hepa type filter vacuums Screeds dry at 1mm per day up to 40mm and 0.5mm per day above 40mm, but can take longer, as this is in good weather conditions which are rarely achieved in the UK.
12 Thank you for your time, any questions?
The Drying Time of Gypsol Screed
1 SYNOPSIS Trials were carried out on full size rooms, specially constructed for testing purposes, and in a strictly controlled laboratory environment, and showed the following: 1.1 Gypsol anhydrite screeds
More informationMethod Statement. General Site preparation by others: Preparation for screed system by others: Preparation for plate system by others:
Method Statement. The One Stop Solution for Underfloor Heating. General Site preparation by others: Work areas to receive UFH must be watertight, dry, clean and clear of any debris or moveable obstructions.
More informationUSERS MANUAL. Desiccant Dehumidifier. Model: ECO DD322FW CLASSIC
keeping your home safe and clean USERS MANUAL Desiccant Dehumidifier Model: ECO DD322FW CLASSIC Read This Manual Inside you will find many helpful hints on how to use and maintain your dehumidifier properly
More informationChurch Heating. Diocese of St Albans Diocesan Advisory Committee Advisory Leaflet 47
Diocese of St Albans Diocesan Advisory Committee Advisory Leaflet 47 Church Heating Introduction This guidance leaflet looks at the need to heat a church building for different usage and the options that
More informationDesiccant Dehumidification - Effective Strategy for Drying Concrete Slabs
Desiccant Dehumidification - Effective Strategy for Drying Concrete Slabs Rick Toman Business Development Strategist Polygon US Corporation 314-914-1256 richard.toman@polygongroup.com July 2016 Presentation
More informationSYSTEM DATA SHEET Sikafloor MultiDur ES-44 ESD
SYSTEM DATA SHEET SMOOTH, UNICOLOUR EPOXY FLOOR COVERING WITH POLYURETH- ANE ESD ROLLER COATING PRODUCT DESCRIPTION The system is a seamless, smooth, low VOC, ESD epoxy floor covering. It consist out of
More informationMaincor Underfloor Heating UNDERFLOOR HEATING SYSTEMS. Introduction. Overview. Tel: Web: Why use Underfloor Heating?
UNDERFLOOR HEATING SYSTEMS Introduction Underfloor heating (UFH) is not a new concept; it was brought to Britain about 2,000 years ago by the Romans. Their heating technique was to allow hot gasses from
More information5 YR CARPET TILE MANUFACTURING WARRANTY 15 YR LIMITED CARPET TILE WEAR WARRANTY
5 YR CARPET TILE MANUFACTURING WARRANTY All our carpet and carpet tiles are covered by the Belgotex Floorcoverings (Pty) Ltd 5-year guarantee against patent and latent defects in the manufacturing process.
More informationWARM WATER UNDERFLOOR HEATING SYSTEMS. Guidance Notes
WARM WATER UNDERFLOOR HEATING SYSTEMS Guidance Notes 02 WARM WATER UNDERFLOOR HEATING SYSTEMS Introduction Underfloor heating systems consist of a series of pipes which are integrated into the floor structure
More informationWhy Vaillant? Home Heating Guide. Because they can reduce our heating bills and our carbon footprint
Home Heating Guide Why Vaillant? Because they can reduce our heating bills and our carbon footprint Because we re here to help If you have any questions, please call 01634 292300. We can also give you
More informationEnriching Environments
Enriching Environments 2 Enriching Environments We understand the difference an improved internal environment can make 3 Contents 4 5 6 7 8 9 10 11 About us Heating and cooling coils Fan convectors Trench
More informationabout your house Choosing a Dehumidifier
about your house CE 27 Moisture in house air can be a problem when there is either too little or too much. Air that is too dry can cause discomfort, dried and itchy skin and nasal passages, cracked or
More informationIMPORTANT SAFETY INSTRUCTIONS
User s Manual Inside you will find many helpful hints on how to use and maintain your dehumidifier properly. Just a little preventative care can save you money and prolong the life of your unit. INDEX
More informationESRTD2 Electronic Room Thermostat, with LCD Display
ESRTD2 Electronic Room Thermostat, with LCD Display Version 4.2 sales@esicontrols.co.uk ESI Controls Limited http://www.esicontrols.co.uk User and Installation Instructions INDEX User and Installation
More informationInstallation Guide. Maximum Area 20m 2
Installation Guide Maximum Area 20m 2 i PLEASE READ THIS INSTALLATION GUIDE CAREFULLY BEFORE BEGINNING ANY WORK TO ENSURE A SAFE & TROUBLE FREE INSTALLATION. Parts provided with pack 4 Parts provided with
More informationBOILING UNIT REDITAP. Installation and User Guide. IMPORTANT: This booklet should be left with the user after installation and demonstration
in tap Boiling water to in tap sink Drain Valve (as high as possible) REDITAP CONNECTION SUMMARY Amp mains supply cold mains water into in tap optional filter cold water in hot water BOILING UNIT Installation
More informationEnergy Ambassadors Guide
Energy Ambassadors Guide Energy Ambassadors Home Visit Guide Instructions for use This home visit guide has been developed to help non-energy professionals to identify energy related issues in their clients
More informationUnderstanding your Central Heating System
Understanding your Central Heating System PH Jones is a trading name of British Gas Social Housing Limited (registered in England and Wales under company number 01026007) whose registered office is Millstream,
More informationUponor. THE NATIONAL ENERGY FOUNDATION Ground Source Heat Pump Seminar 12 th May Who Are We???????? Radiator
1 Heat Pumps And Underfloor Heating A Match Made In Heaven? Introduction Steve Alldritt Business Development Manager: Central Region Uponor Housing Solutions Ltd THE NATIONAL ENERGY FOUNDATION Ground Source
More informationDigital Room Thermostat with TPI & Delayed Start User Instructions
ESRTD5 & ESRTD5VF Digital Room Thermostat with TPI & Delayed Start User Instructions Thank you for choosing ESi Controls. All our products are tested in the UK so we are confident this product will reach
More informationKills bills. How Vaillant technologies reduce home heating bills
Kills bills How Vaillant technologies reduce home heating bills Energy efficiency is a choice For most people, home heating and hot water systems have always been out of sight and out of mind. But now,
More informationMeaco Platinum Range Instruction Manual
Meaco Platinum Range Instruction Manual Meaco 12L and 20L Low Energy Dehumidifiers Please read this instruction manual before using the dehumidifier and keep safe for future reference. Thank you for choosing
More informationPASSIVE FIRE PROTECTION GETTING IT RIGHT
PASSIVE FIRE PROTECTION GETTING IT RIGHT Niall Rowan Technical Officer Association for Specialist Fire Protection Contents Who is the ASFP? Passive Fire Protection What is it? How does it work? The installation
More informationRoger Bell dip. arch. tech. Bsc. CAD
BELL ASSOCIATES ARCHITECTURE PLANNING Roger Bell dip. arch. tech. Bsc. CAD Rogerstown, Rush, Co. Dublin. Muchgrange, Greenore, Co. Louth E bellassociates@eircom.net T 01-8430267 T 042 938 3865 M 087 2371984
More informationINSTALLATION INSTRUCTIONS ONE LARGE ZONE
INSTALLATION INSTRUCTIONS ONE LARGE ZONE Unit 1 79 Friar Street Worcester WR1 2NT Tel: 01905 354 791 Fax: 01905 352 100 E-mail: info@underfloorheatingsystems.co.uk Website: www.underfloorheatingsystems.co.uk
More informationINSTRUCTIONS MODEL: MWBT
Page 1 of 15 INSTRUCTIONS MODEL: MWBT SAFETY INSTRUCTIONS INSTALLATION INSTRUCTIONS OPERATION INSTRUCTIONS MAINTENANCE INSTRUCTIONS WIRING DIAGRAM EXPLODED VIEW / PARTS LIST WARRANTY INFORMATION DISPOSAL
More informationtechnical specification smoke venting systems
technical specification smoke venting systems An Introduction to FDS FDS sets the standards the rest of the industry follows Providing a complete service for all of your smoke ventilation system needs.
More informationAssessment Schedule - TS.6
The Assessor shall determine the business s commitment and support to good and safe working practices; also that it has a positive culture in all aspects of its work. In particular, the assessor shall
More informationUSERS MANUAL. Desiccant Dehumidifier. Model: ECO DD322FW SIMPLE. Read This Manual
keeping your home safe and clean USERS MANUAL Desiccant Dehumidifier Model: ECO DD322FW SIMPLE Read This Manual Inside you will find many helpful hints on how to use and maintain your dehumidifier properly.
More informationTHE COMPLETE SOLUTIONS PACKAGE
THE COMPLETE PACKAGE C O R P O R A T E LEAK DETECTION AND VACUUM SPECIALISTS THE COMPLETE PACKAGE. Vaseco is one of the most respected companies in the vacuum, leak detection and pressure industries and
More informationWRF04 CO2. Application. Types Available. Security Advice Caution. Combined room sensor CO 2 / temperature / humidity. Datasheet
WRF04 CO2 Combined room sensor CO 2 / temperature / humidity 281836 Datasheet Subject to technical alteration Issue date: 26.02.2016 Application Surface mounted sensor for detection of CO2, temperature
More informationMini Tender Section 1.1 External Wall Insulation, Mechanical and Electrical Installation
Mini Tender Section 1.1 External Wall Insulation, Mechanical and Electrical Installation BOILER ONLY INSTALLATION ALL ITEMS BLEOW SHOULD BE INCLUDED WITHIN TENDER COST OR CONSIDER WITHIN BIDDERS SUBMISSION
More informationEnergy Efficiency RETAIL.
Energy Efficiency RETAIL www.energia.ie Your chance to reduce your business energy usage by as much as 20%! 20% is a significant figure and reducing your energy bill by this amount could make a real change
More informationControlling condensation in your home
Controlling condensation in your home www.westwardhousing.org.uk If you or someone you know would like this Controlling condensation in your home leaflet on CD, in large print, in braille, or translated
More informationSecuring your safety
working with FIRE STATISTICS There are around 11 construction site fires everyday in the UK Estimated costs to the industry are 400m per year, or over 1m a day! All sites and buildings under construction
More informationOWNER S GUIDE READ AND SAVE THESE INSTRUCTIONS
OWNER S GUIDE READ AND SAVE THESE INSTRUCTIONS Record Model No. and Serial No. of this dehumidifier in space provided below. These numbers are printed on the nameplate located behind the bucket. M odel
More informationWRF04 CO 2 RS485 Modbus
WRF04 CO 2 RS485 Modbus Combined room sensor CO 2 / temperature / humidity Datasheet Subject to technical alteration Issue date: 26.02.2016 Application Surface mounted sensor for detection of CO2, temperature
More informationUSERS MANUAL. Desiccant Dehumidifier. Model: ECO DD122FW CLASSIC. Read This Manual
keeping your home safe and clean USERS MANUAL Desiccant Dehumidifier Model: ECO DD122FW CLASSIC Read This Manual Inside you will find many helpful hints on how to use and maintain your dehumidifier properly.
More informationMeaco 10L small home dehumidifier Instructional Manual
Meaco 10L small home dehumidifier Instructional Manual Meaco 10L Small Home Dehumidifier Please read this instruction manual before using the dehumidifier and keep safe for future reference. PRODUCT DESCRIPTION
More informationUnderstand and apply domestic central heating system installation and maintenance techniques
Level: 2 Credit value: 10 URN: Y/602/2888 Unit aim This combination unit provides basic learning in the installation, maintenance, decommissioning and soundness testing of a basic range of wet central
More informationINTERCYL. INTERNAL EXPANSION EXCELLENCE
INTERCYL. INTERNAL EXPANSION EXCELLENCE ISSUE ONE JANUARY 2017 UNVENTED WATER STORAGE FROM THE EXPERTS... FOR MORE INFORMATION GO TO WWW.RMCYLINDERS.COM INTRODUCING InterCyl Introducing the latest product
More informationUnderfloor heating. user guide. DS thermostats with timeclock. Nu-Heat v18 UNDERFLOOR HEATING HEAT PUMPS SOLAR THERMAL
Underfloor heating user guide DS thermostats with timeclock v18 Nu-Heat 2018 UNDERFLOOR HEATIN HEAT PUMPS SOLAR THERMAL working with you before, during & after your project Nu-Heat Know-How 2 For expert
More informationINSTALLATION INSTRUCTIONS SINGLE CIRCUIT
INSTALLATION INSTRUCTIONS SINGLE CIRCUIT Unit 1 79 Friar Street Worcester WR1 2NT Tel: 01905 616 928 Fax:01905 611 240 E-mail: info@underfloorheatingsystems.co.uk Website: www.underfloorheatingsystems.co.uk
More informationOperation manual. Dehumidifier CFO-20N
Operation manual Dehumidifier CFO-20N CONTENTS IMPORTANT INSTRUCTIONS... 1 IMPORTANT SAFETY INFORMATION... 2 ABOUT THE CONTROLS ON THE DEHUMIDIFIER... 3 USING THE DEHUMIDIFIER... 4 CARE AND CLEANING OF
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS Unit 1 79 Friar Street Worcester WR1 2NT Tel: 01905 616 928 Fax:01905 611 240 E-mail: info@underfloorheatingsystems.co.uk Website: www.underfloorheatingsystems.co.uk ngsystems.co.uk
More information10 tips for getting more reliability from your air-conditioning system [reliability]
10 tips for getting more reliability from your air-conditioning system [reliability] A guide for installers, specifiers, contractors and architects February 2010 10 tips for getting more reliability from
More informationA new park will be delivered as part of the Elephant Park regeneration.
A new park will be delivered as part of the Elephant Park regeneration. The exhibition boards presented here introduce the first phase of the new park that is scheduled to open in spring 2017 that has
More informationTimbersoft Hybrid Kiln - moving towards more production orientated eco friendly drying
Timbersoft Hybrid Kiln - moving towards more production orientated eco friendly drying With an increased focus on global warming, and the carbon footprint left by industry, We decided in 2012 to harness
More informationRecommendations texts (9.82) to be used on Energy Report in Scotland 18 July 2008
s texts (9.82) to be used on Energy Report in Scotland 18 July 2008 Note. The recommendations are picked up by software using the recommendation number (see SAP 2005 version 9.82, Appendix T). Where the
More informationEC 160 CO 2. Incubator
EC 160 Incubator EC 160 Incubator OPTIMIZED CULTURE CONDITIONS Reproducible and reliable cell growth is dependent upon three critical parameters, temperature, concentration and relative humidity. EC 160
More informationINSTALLATION INSTRUCTIONS
UNION WALL MOUNTED BASIN MONO UB111WNC/L/U/B INSTRUCTIONS INTRODUCTION DIMENSIONS Please read these instructions carefully and keep in a safe place for future reference. General Installation Requirements.
More informationVision Air Conditioning Range Condenser-less Air Conditioner
Powrmatic Vision 2.3 Condenser-less Air Conditioner Includes DC Inverter & Low Temperature Hot Water Models Vision Air Conditioning Range Condenser-less Air Conditioner S T Y L I S H & C O S T E F F E
More informationDehumidifier/Dryer. Model: EDV Please read the instruction manual before operating. Keep in a safe place for future reference
Dehumidifier/Dryer Model: EDV-4000 Please read the instruction manual before operating. Keep in a safe place for future reference IMPORTANT SAFETY INSTRUCTIONS PLEASE READ ALL INSTRUCTIONS CAREFULLY BEFORE
More informationTechnical Bulletin 008 (Edition 2) CIP-RACL Developed by Industry
Technical Bulletin 008 (Edition 2) CIP-RACL Developed by Industry Title: Room-sealed fanned-draught chimney/flue systems concealed within voids Consumer Information Pack and Risk Assessment Checklist Date
More informationabout your house Before You Start an Energy-Efficient Retrofit Mechanical Systems
about your house CE 28i Before You Start an Energy-Efficient Retrofit Mechanical Systems One of the best ways to make your home more comfortable, healthier and less expensive to operate is to upgrade the
More informationUNDERFLOOR HEATING SYSTEM C SYH ME UNDERFLOOR HEATING SYSTEM. Heating Homes All Around The World.
C SYH ME Heating Homes All Around The World www.buteline.co.uk About Buteline Buteline TM was developed and established by its founder and current Managing Director, David J. Picton, in 1980 taking a small
More informationV. (Versus ) Bare Floor Vacuum
V. (Versus ) Bare Floor Vacuum USER S GUIDE 76T8 SERIES 3 Safety Instructions 4 Product View 5 Assembly 6 Operation 7-8 Maintenance and Care 9 Troubleshooting 10 Consumer Services 11 Replacement Parts
More informationThe Professional s Choice
SureFlow compact range: 1000-C & 1000-M Auto-Fill Catering Water Boiler Installation And User Instructions The Professional s Choice CONTENTS CONTENTS & INTRODUCTION 2 SAFETY & ENVIRONMENTAL INFORMATION
More informationTOTALCLEAN AIRPURIFIER. instruction manual. YEARGuarantee AP-25A-GB
TOTALCLEAN AIRPURIFIER instruction manual AP-25A-GB YEARGuarantee READ ALL INSTRUCTIONS BEFORE USE. SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. IMPORTANT SAFEGUARDS: WHEN USING ELECTRICAL PRODUCTS, ESPECIALLY
More informationGuidelines to Green Roofing
The Green Roof Organisation (GRO) Excellence in Green Roofs Guidelines to Green Roofing GRO is a partnership of Industry and Stakeholders coming together to develop guidance for specification, design,
More informationMARKET LEADERS IN LARGE SCALE COMMERCIAL CLEANING SERVICES
WHY TECMASTER? MARKET LEADERS IN LARGE SCALE COMMERCIAL CLEANING SERVICES We regard the promotion and development of an effective cleaning program to your catering department as an essential service. This
More informationyour comfort. our world. Altherma Flex Type Renewable heat pump system for every environment
your comfort. our world. Altherma Flex Type Renewable heat pump system for every environment Outdoor One or more indoor or outdoor units Indoor 1 Domestic hot water 2 Heating 3 Cooling Daikin Altherma
More informationX A M G3/4 G3/
180 172 MAX30 2-35 43 G3/4 G3/4 209 165 ! COVER CAP MIXER HANDLE HEXAGONAL KEY SEAL CARTRIDGE MIXER BODY This product should only be fitted by a qualified plumber to NVQ (National Vocational Qualification)
More informationFEATHERWEIGHT PRO USER GUIDE 1703 SERIES
FEATHERWEIGHT PRO USER GUIDE 1703 SERIES IMPORTANT SAFETY INSTRUCTIONS READ ALL INSTRUCTIONS BEFORE USING YOUR VACUUM. When using an electrical appliance, basic precautions should be observed, including
More informationPump Shower Drainage Solutions
Pump Shower Drainage Solutions Independent living quietly confident Proud to manufacture in the UK Where gravity drainage is not an option... Whale can help Gravity drainage is not always an option when
More informationESRTD3. Digital Room Thermostat with TPI & Delayed Start. User and Installation Instructions
ESRTD3 Digital Room Thermostat with TPI & Delayed Start User and Installation Instructions INDEX User Instructions What is a Room Thermostat? 1 What is Chronoproportional Control (TPI)? 3 What is Delayed
More informationVentilation & Heat Recovery. The whole house system from OMNIE
Ventilation & Heat Recovery The whole house system from OMNIE 2 Contents ABOUT OMNIE 4 The Whole house system 6 Why OMNIE Ventilation & Heat Recovery? 7 How does it work? PRODUCT 9 Comfo Air Q MVHR Unit
More informationHOW TO TEST YOUR ECOTILE ESD FLOOR
HOW TO TEST YOUR ECOTILE ESD FLOOR WHAT ARE YOU TRYING TO ACHIEVE? We would recommend that all customers try to ensure that they achieve and maintain a floor that meets the internationally recognised standard
More informationFlexible and efficient: Close Climate Control for IT equipment
GEA Multi-DENCO Flexible and efficient: Close Climate Control for IT equipment engineering for a better world GEA Heat Exchangers GEA Multi-Denco at a glance: Multiple functions and applications High flexibility
More informationHHIC consumer guide to gas boiler servicing
HHIC consumer guide to gas boiler servicing Gas Boiler Servicing Keep your home heating system in good working order. As a consumer, it is reasonable to assume that when procuring a service of your gas
More informationc. DTAH Toronto Complete Streets Guidelines
c. DTAH Toronto Complete Streets Guidelines 164 166 C.1 Project Delivery Process 168 C.5 This section provides a summary of the overarching process for delivering street projects in Toronto. The conclusion
More informationLGR Dehumidifier Owner s Manual
LGR Dehumidifier Owner s Manual 115v Model: DH 075 ORG Please read this owner s manual before operating and keep safe for future reference GENERAL INFORMATION Thank you for choosing our LGR Dehumidifier
More informationCommercial Hot Water Solutions Ltd.
FOR THE SUPPLY OF: Hot Water Generators Single & Twin Coil Vessels Buffer Vessels Gas Fired Continuous Flow Water Heaters with Buffer Storage www.chwsltd.co.uk CHWS Ltd provides specialist services for
More informationWILLASTON MEMORIAL HALL REGISTERED CHARITY NUMBER FIRE RISK ASSESSMENT
WILLASTON MEMORIAL HALL REGISTERED CHARITY NUMBER 520090 FIRE RISK ASSESSMENT February 2017 Description of Premises Willaston Memorial Hall is a stone-built single-story community building situated on
More informationPower BAGLESS CYCLONIC CYLINDER VACUUM LET S GET STARTED.
Power BAGLESS CYCLONIC CYLINDER VACUUM LET S GET STARTED. CCMBPCV1P1 CCMBPCV1T1 CCMBPCV1C1 CCMBPNV1P1 CCMBPNV1T1 CCMBPNV1C1 CCMBPDV1P1 CCMBPDV1T1 CCMBPDV1C1 CCMBPV1P1 CCMBPV1T1 CCMBPV1C1 Let s talk safety
More informationFURNACES & OVENS LEADING INNOVATORS IN THERMAL TECHNOLOGY TO THE OIL & GAS, CHEMICAL AND POWER INDUSTRIES ASSET INTEGRITY PARTNER
FURNACES & OVENS LEADING INNOVATORS IN THERMAL TECHNOLOGY TO THE OIL & GAS, CHEMICAL AND POWER INDUSTRIES ASSET INTEGRITY PARTNER Stork Cooperheat design and manufacture industry leading furnaces and ovens
More informationPRODUCT MANUAL OPERATION, INSTALLATION AND MAINTENANCE MANUAL. Indoor Convective Panel Heater
PRODUCT MANUAL OPERATION, INSTALLATION AND MAINTENANCE MANUAL Indoor Convective Panel Heater CONTENTS Rev A NOV14 1. Product Overview 2. Specification Data 3. Operations 4. Installation 5. Safety 6. Maintenance
More informationINSTALLATION INSTRUCTIONS
ISTALLATIO ISTRUCTIOS Unit 1 79 Friar Street Worcester WR1 2T Tel: 01905 616 928 Fax:01905 611 240 E-mail: info@underfloorheatingsystems.co.uk Website: www.underfloorheatingsystems.co.uk 1. Installation
More informationUnderfloor Heating Installation Guide
Underfloor Heating Installation Guide Beneath Heat Ltd Unit 3, Dunne s Farm, Laindon Road, Horndon On The Hill, Essex. SS17 8QB. Tel: 01268 543475 Fax: 01233 221616 Email: info@beneathheat.co.uk www.beneathheat.co.uk
More informationUB110DNC/L/U/B BASIN MONOBLOC WITH NO POP-UP WASTE BASIN MONOBLOC TALL WITH NO POP-UP WASTE UB112DNC/L/U/B INSTALLATION INSTRUCTIONS
BASIN MONOBLOC WITH NO POP-UP WASTE BASIN MONOBLOC TALL WITH NO POP-UP WASTE UB110DNC/L/U/B UB112DNC/L/U/B INSTRUCTIONS INTRODUCTION DIMENSIONS Please read these instructions carefully and keep in a safe
More informationRoyden. Look how easy it is to roll out the heat
Royden Look how easy it is to roll out the heat 6 good reasons to select Royden infloor heating foil 1. Easily installed Royden heating foil comes on the roll, ready to fit. Whatever the room size or shape
More informationA GUIDE TO THE REGULATORY REFORM ORDER (FIRE SAFETY) 2005 (RRO)
4 PEEL HOUSE,TAUNTON STREET,SHIPLEY,BN18 3NA TEL: 01274 595015 FAX: 01274 580804 EMAIL:sales@rosse-systems.co.uk A GUIDE TO THE REGULATORY REFORM ORDER (FIRE SAFETY) 2005 (RRO) THE PURPOSE OF THIS DOCUMENT
More informationLo-Carbon Sentinel Kinetic Horizontal
Lo-Carbon Sentinel Kinetic Horizontal MVHR Unit Features & Benefits Manufactured in the UK Building Regulations ADF compliant Recognised in SAP Appendix Q Energy Savings Trust best practice compliant Up
More informationEquipment guide for local exhaust ventilation (LEV)
Nederman equipment guide brochure LEV_Layout 1 29/09/2014 13:43 Page 1 Equipment guide for local exhaust ventilation (LEV) Extraction products, systems and solutions available Nederman is one of the world'
More informationTool Hire Specialists Market Report - UK Analysis
Tool Hire Specialists Market Report - UK 2016-2020 Analysis Published: 22/11/2016 / Number of Pages: 82 / Price: 845.00 Introduction & Overview The 11th edition of the 'Tool Hire Specialists Market Report
More informationEnhance the performance of every system
professional controls for underfloor heating Enhance the performance of every system FLOOR HEATING HYDRONIC FLOOR HEATING ELECTRIC HVAC CONTROLS & POWER OJ Waterline 3 RD GENERATION WATERBASED UNDERFLOOR
More informationMaintenance Solutions from SE Controls
Maintenance Solutions from SE Controls Maintenance Solutions from SE Controls SE Controls is a leading international specialist in the design and delivery of intelligent smoke and environmental ventilation
More informationEnergy Saving Fact Sheet Agriculture & Horticulture
Energy Saving Fact Sheet Agriculture & Horticulture It s easier than you think to grow savings! Farming today is all about quality, yields and returns, and nothing eats into your profits like energy use.
More informationPhoto courtesy of U.S. Navy. ARID-Dry. Restoration and Construction Drying Equipment Mobile Desiccant Dehumidifiers Temporary Humidity Control
Photo courtesy of U.S. Navy ARID-Dry Restoration and Construction Drying Equipment Mobile Desiccant Dehumidifiers Temporary Humidity Control INTRODUCING Controlled Dehumidification IMS Controlled Dehumidification
More informationFitting & Commissioning Instructions. EcoBlue Combi and System Range. Outdoor Sensor Kit. Kit Part No (System) Kit Part No.
United Kingdom en Fitting & Commissioning Instructions Outdoor Sensor Kit EcoBlue Combi and System Range Kit Part No. 7214286 (System) Kit Part No. 7213356 (Combi) These instructions should be read in
More informationINSTALLATION INSTRUCTIONS
BATH SHOWER MIXER WITH KIT UB422DC/L/U/B INSTRUCTIONS INTRODUCTION DIMENSIONS Please read these instructions carefully and keep in a safe place for future reference. General Installation Requirements.
More informationOneZone. Underfloor heating range. For existing properties & new build extensions. Extensions Conservatories Single rooms HEAT PUMPS
Extensions Conservatories Single rooms OneZone Underfloor heating range For existing properties & new build extensions UNDERFLOOR HEATING HEAT PUMPS SOLAR THERMAL Contents Warm water underfloor heating
More informationGIACOMINI UNDERFLOOR HEATING CONTROLS GUIDE
GIACOMINI UNDERFLOOR HEATING CONTROLS GUIDE PAGE 2 DOCUMENT CONTENT COMPONENT OVERVIEW P4 BASIC CONTROLS INC. COMPARISON CHART P6 CHAPTERS INTERMEDIATE CONTROLS INC. COMPARISON CHART ADVANCED CONTROLS
More informationCare instructions. for wood floors
Lobis Care instructions for wood floors Lobis Oiled surfaces Maintenance: For daily maintenance, use the vacuum cleaner with a soft brush or a broom. At regular intervals, depending on the strain and the
More informationPLAY AREA LANDSCAPING
PLAY AREA LANDSCAPING FOR MAXIMUM IMPACT ABSORPTION FEATURING: BS EN PLAY SAFETY SURFACINGS WORLD-RENOWNED ARTIFICIAL GRASS RANGE STRIKING SLEEPERS FOR SAND PITS & EDGING COMPREHENSIVE RANGE OF MATERIALS
More informationServices. Monitoring. t f e. w.
Monitoring SES Ltd provides a range of monitoring services, including CCTV systems at client locations. As we are not tied to any specific manufacturer, this enables us to monitor CCTV systems from a vast
More informationINSTRUCTIONS FOR LAYING OF WOOD FLOORING ON UNDERFLOOR RADIANT HEATING AND COOLING
INSTRUCTIONS FOR LAYING OF WOOD FLOORING ON UNDERFLOOR RADIANT HEATING AND COOLING TRADITIONAL HEATING SYSTEM 20 C 22 C 40 C 17 C The standard of reference for underfl oor heating systems for residential
More informationAdvance Autoclave. Designed to give you more for your money with a high capacity for faster throughput: More features and benefits...
Advance Advance Designed to give you more for your money with a high capacity for faster throughput: The Advance has a much bigger capacity than its main competitors and yet has one of the smallest footprints
More informationUSER GUIDE VOGUE MAX SYSTEM
USER GUIDE VOGUE MAX SYSTEM 15 18 26 32 When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance specification that we require. Do not
More informationWhen using electrical appliances, basic safety precautions should always be followed. These instructions should be saved for future reference:
IMPORTANT SAFEGUARDS When using electrical appliances, basic safety precautions should always be followed. These instructions should be saved for future reference: Read and familiarise yourself with all
More information