1 Identifying Heating Controls, Meters and Flues.
2 Identifying Heating controls and Flues Gas and Electric meters Programmers Room Thermostats TRVs HWC Thermostats Flues Emitters TOP TIPS IN IDENTIFYING THE USUAL/UNUSUAL;
3 GAS AND ELECTRIC METERS Gas and electric meters can cause confusion due to the many types fitted over the years and to their labelling. Some old Duel Rate meters have been converted to Single Rate meters. Look for any Servicing Documents attached to the meter or a fuel bill.
4 Old and new type of Single Rate Meter
5 Single Phase does NOT mean Single Rate.
6 Single Rate.
7 The simple Duel Rate Meter.
8 Some types of meters can be Single or Duel Rate. This meter requires you to watch the display as it cycles to determine its Rate. These meters require you to press the blue button to cycle the display.
9 Top Tip... For Duel Rate meters, take your photo when the display shows the other Rate. Evidence that it is NOT a Single Rate Meter.
10 Pre Paid meters can be Single or Duel Rate. There is usually a label showing the rate. Payment Key.
11 Two Gas Meters. One is Mains Gas and the other Calor Gas (LPG). Which is the Calor Gas meter?
12 Take a closer look.
13 Look for this Red Cap as a clue. Or even this on the flap door?.
14 LPG BULK STORAGE Bulk Storage supplying more than one house.
15 The LPG metered houses can be found on housing estates and clusters of houses that have a bulk storage tank supplying the whole estate/development. Therefore the Energy Assessor could be caught out by not seeing any LPG cylinders or LPG storage tanks at that one particular property. Entering the RdSAP data as Mains Gas and not LPG will result in a gross error. i.e. A 2006 build property could show an Energy Rating of; On Mains Gas Band C On LPG Band F A BIG difference!
16 Programmers and Room Thermostats A combined Programmer and Room Stat For DHW and Heating. Programmer Room Stat Control.
17 Programmer for DHW and Heating.
18 Top Tip... If the property has a programmer, such as this... AND has this old type Programmer/Room Stat... Be aware that this old unit, although not now used as the programmer, can be wired to still act as a Room Thermostat.
19 Integral Programmers on a Boiler.
20 Integral Programmer on the Boilermate type systems.
21 A Heating Management System
22 Multi Channel Programmer for Zone Control
23 THE ROOM THERMOSTAT Old and New Room Thermostats.
24 The elusive Wireless Programmer/Room Stat. These can be anywhere, even hidden behind a Birthday Card!
25 Or hidden amongst ornaments.
26 And this very small Wireless Room Stat could be missed...
27 And even the older Room Stat may not be where you would expect it!
28 And another unexpected place! Note: Under floor Heating Thermostats can be found at this height also..
29 Under floor Heating The Thermostat is normally close to the floor. Each room, with under floor heating, will have such a Thermostat.
30 Top Tip... Having found the Room Thermostat down stairs, always check upstairs for a second thermostat... ZONE CONTROL?
31 Zone Control Time and Temperature Zone Control. To enter this system, there must be a programmer and room thermostat for every zone.
32 Top Tip... Be aware that some Programmers are now Multi Channel and as such constitute Zone Control
33 Thermostatic Radiator Valves(TRVs)
34 A Thermostatic Radiator Valve (TRV) is added to each individual radiator to permit different room temperatures around the home. The TRV controls the room temperature by reading the current air temperature and appropriately opening or closing the inlet valve to the radiator to achieve the preset temperature.
35 These are NOT a TRVs. These valves ONLY maintain the temperature of THAT radiator, regardless of the room temperature.
36 The unusual...
37 The Water filled, Wall Fixed, Stand Alone Radiator. Electrically heated. Each radiator can be controlled by a timer. Radiators of this type also allows the setting of the desired room temperature. (i.e. TRV).
38 Hot Water Cylinder Thermostats
39 Typical Thermostats.
40 Thermostats can be easily missed... Is there a Thermostat on this tank?..
41 The Factory Set Thermostat. Found at the bottom of the HWC.
42 And the unusual...
43 Connected to this temperature control unit to the boiler. ( Hidden on the reverse wall). A Thermo Sensor.
44 This type of valve can be found attached to the in pipe of the HWC from the boiler. The thin silver wire is a heat sensor attached from the HWC to the valve. This is NOT classed as a HWC Thermostat
45 This type of system is not classed as a Cylinder Stat as it does not DIRECTLY shut the boiler off once the HWC has reached the required set temperature. Hot water from the boiler goes through the valve and then through the coiled pipe in the HWC, heating the DHW (Indirect Heating). Once the DHW has reached the required temperature, the valve shuts off the heated water from the boiler. However this does not shut off the boiler. The boiler will continue to run until the boiler s own thermostat shuts it down.
46 Top Tip... As an Energy Assessor you may not think to take a photo of this, as it is not a cylinder stat. Although you know this is NOT a Cylinder Thermostat, the present occupier may think it is a cylinder thermostat. Explain this to the home owner. Take photos of this system to back up your EPC Report.
47 Flues
48 The Fan Assisted Flue one with a Twist......and a Stubby one
49 Fan Assisted Flue, Proud of the wall.
50 Fan Assisted Flue.
51 The Balanced Flue (Gas).
52 Balanced flue for a Floor mounted oil boiler.
53 Balanced flue for a wall mounted oil boiler.
54 Flue Terminal for Back boiler. This would be attached to the back boiler via a flue liner.
55 Clay pot for an open fire.
56 Terraced properties with a mixture of Back boiler and open fires.
57 Oil Boiler Flue Terminal (Open).
58 Vertex Flues (Fan Assisted). Gas.
59 Wallstar Oil Boiler Flue.
60 The Ridge Terminal Flue. Look for this flue liner in the Loft Space.
61 Oil Boiler Flue. Fan Assisted.
62 Fan Assisted Oil Boiler Flue (Condensing). Note the Condensing Pipe (Plastic).
63 Top Tip... The Condensing Pipe from a Condensing Boiler is made of plastic. This is because the condensed water is very acidic and so would corrode through a copper pipe. It is not unusual to find that the Condensing Pipe to be made of copper. Installed by a unqualified Plummer? Inform the home owner of this, as they could have leakage in the future!
64
65
Stroma Certification Ltd
Stroma Certification Ltd CPD Guide: Secondary Heating This Guide has been created to tackle areas of poor knowledge relating to secondary heating. There is a question section at the end of the Guide for
More informationAppendix T: Improvement measures for Energy Performance Certificates
Appendix T: Improvement measures for Energy Performance Certificates Table T1 defines the circumstances under which recommendations for improvements are made on EPCs. For properties in England & Wales
More informationAppendix T: Improvement measures
Appendix T: Improvement measures The table defines the circumstances under which recommendations for improvements are made. For England & Wales and Scotland software tests for the relevance of improvement
More informationImprovement schedule for SAP May 2014 Note 8 revised 29 May 2014 NI high/further measures corrected 17 July 2014
Improvement schedule for SAP 9.92 9 May 2014 Note 8 revised 29 May 2014 NI high/further measures corrected 17 July 2014 Changes vis-à-vis RdSAP 9.91 shown in red. Table of improvement measures For England
More informationStroma Certification Ltd
Stroma Certification Ltd CPD Assessment Guide: Boiler Identification This Guide explains boiler identification and use of PCDF according to the RdSAP software. There is a question section at the end of
More informationKills bills. How Vaillant technologies reduce home heating bills
Kills bills How Vaillant technologies reduce home heating bills Energy efficiency is a choice For most people, home heating and hot water systems have always been out of sight and out of mind. But now,
More informationThis RdSap refresher course covers everything you would have learnt in your original training on the following aspects:
RdSap Refresher Course Part 3 This RdSap refresher course covers everything you would have learnt in your original training on the following aspects: - Space heating - Water Heating - Renewable Technologies
More informationDOMESTIC HEATING CONTROLS ARE EASY PART 1 - THE BASICS
DOMESTIC HEATING CONTROLS ARE EASY PART 1 - THE BASICS Today s inescapable need to improve energy efficiency in UK homes has brought installers many opportunities to make extra earnings through the upgrading
More informationDaikin Altherma Hybrid User Guide
Daikin Altherma Hybrid User Guide Your new Daikin Altherma hybrid heat pump In this guide you will find information and guidelines that will allow you to run your Daikin Altherma hybrid heat pump system
More informationThe Green Deal Occupancy Assessment
The Green Deal Occupancy Assessment Outline of the Green Deal Home visit and the Occupancy Assessment 2 Outline of the Green Deal Home Visit Occupancy Assessment 1. Contact the customer in advance of the
More informationRdSAP Conventions for SAP 2009
RdSAP Conventions for SAP 2009 11 March (v4.0) New and amended conventions for v4.0 indicated by light blue background. Note: This list will be extended as appropriate. # Topic Conventions Issue date General
More informationBoiler Replacement Scheme Boiler Installer Form
Boiler Replacement Scheme Boiler Installer Form The applicant for the Boiler Replacement Scheme should ask their installer to complete this Form and return it, when completed, to the Housing Executive.
More informationFrequently Asked Questions
What is a Thermostatic Radiator Valve? TRVs sense the air temperature around them and regulate the flow of water through the radiator which they are fitted to. They do not control the boiler.they should
More informationEnergy and you. A guide to energy efficiency in your home. Energy and You A5.indd 1 26/10/ :15
Energy and you A guide to energy efficiency in your home Energy and You A5.indd 1 26/10/2015 16:15 2 Energy and you NCHA is committed to helping you reduce the amount of money you spend on water, gas and
More informationBOILERMATE A CLASS SP
BOILERMATE A CLASS SP USER-GUIDE Gas Council Approved Reference Numbers 89-317-14 / BMA 120 SP 89-317-15 / BMA 140 SP 89-317-16 / BMA 180 SP 89-317-17 / BMA 200 SP 89-317-18 / BMA 220 SP AN SEALED CENTRAL
More informationheat interface units A BOILER WITHOUT A FLAME HIU Single PHE options
A BOILER WITHOUT A FLAME HIU Single PHE options heat interface units Communal Heat Networks A central boiler house will generate heat which is distributed through a network of pipe to each home or apartment
More informationBOILERMATE A CLASS OV
BOILERMATE A CLASS OV USER-GUIDE Gas Council Approved Reference Numbers 89-317-09 / BMA 125 OV 89-317-10 / BMA 145 OV 89-317-11 / BMA 185 OV 89-317-12 / BMA 215 OV 89-317-13 / BMA 225 OV AN OPEN VENTED
More informationWhy Vaillant? Home Heating Guide. Because they can reduce our heating bills and our carbon footprint
Home Heating Guide Why Vaillant? Because they can reduce our heating bills and our carbon footprint Because we re here to help If you have any questions, please call 01634 292300. We can also give you
More informationEnergy Ambassadors Guide
Energy Ambassadors Guide Energy Ambassadors Home Visit Guide Instructions for use This home visit guide has been developed to help non-energy professionals to identify energy related issues in their clients
More informationDate of assessment: 08 February 2014 Date of certificate: 10 February 2014 Reference number:
Energy Performance Certificate Northern Ireland 385, Oldpark Road BELFAST BT14 6QS Date of assessment: 08 February 2014 Date of certificate: 10 February 2014 Reference number: 0965-2998-0821-9104-3245
More informationA B C D E F G H I J K L M N O P Q R S T U V W X Y Z
A B C D E F G H I J K L M N O P Q R S T U V W X Y Z A B C D E F G H I J K L M N O P Q R S T U V W X Y Z Ambient temperature This is the air temperature within a 21 ºC room at any given time. It depends
More informationDaikin Altherma Small Monobloc User Guide
Daikin Altherma Small Monobloc User Guide Your new Daikin Altherma heat pump In this guide you will find information and guidelines that will allow you to run your Daikin Altherma heat pump system in
More informationA homeowner s guide to the Baxi Neta-tec Combi
A homeowner s guide to the Baxi Neta-tec Combi For latest prices and delivery to your door visit MyTub Ltd - 0845 303 8383 - www.mytub.co.uk - info@mytub.co.uk A history of quality and innovation 1866
More informationEnergy Efficiency in New Housing
Energy Efficiency Best Practice in Housing Energy Efficiency in New Housing Summary of Specifications for England, Wales and Scotland how to achieve the best in energy efficiency in new housing measures
More informationAssessment Schedule - TS.6
The Assessor shall determine the business s commitment and support to good and safe working practices; also that it has a positive culture in all aspects of its work. In particular, the assessor shall
More informationNew Zealand Sales Hotline: Sales Fax:
Robert Bosch (Australia) Pty Ltd Melbourne 1555 Centre Road Clayton Victoria 3168 P (03) 9541 5555 F (03) 9541 5595 Sales Hotline: 1300 30 70 37 Sales Fax: 1300 30 70 38 www.bosch-climate.com.au New Zealand
More informationIMAGINATION SOLAR LTD. Installation Guide B1. Planning the Plumbing and Wiring
Page 1 of 8 IMAGINATION SOLAR LTD Installation Guide B1 Planning the Plumbing and Wiring Unit 4 Montpelier Central, Station Road Bristol BS6 5EE t: 0117 942 6668 f: 0117 942 8998 e: enquiries@imaginationsolar.com
More informationDEA Name Address Line 1 Open Fireplaces Number of rooms with a bath and a shower STROMA No. Address Line 2 Habitable Rooms Number of rooms with
DEA Name Address Line 1 Open Fireplaces Number of rooms with a bath and a shower STROMA No. Address Line 2 Habitable Rooms Number of rooms with mixer and bath Inspection Date Address Line 3 Heated Habitable
More informationPART 5: HVAC & DHW SYSTEMS
PART 5: HVAC & DHW SYSTEMS Building Science Review Building Science Review: HVAC & DHW Systems This document will help you: Correctly answer all parts of the HVAC Systems section in the Home Energy Score
More informationEnergy Efficiency Rating
Energy Performance Certificate Northern Ireland 37, Church Street MAGHERA BT46 5EA Date of assessment: 20 July 2011 Date of certificate: 20 July 2011 Reference number: 9639-0923-6880-4640-9926 Type of
More informationHEATING SYSTEMS. A guide to your central heating system and helpful energy saving advice.
HEATING SYSTEMS A guide to your central heating system and helpful energy saving advice. CONTENTS THE COST OF RUNNING your central heating system GAS CENTRAL HEATING 4 ROOM THERMOSTATS AND TRVS 8 OIL CENTRAL
More informationTHE OXYVENT TANK. Patent No. EP INSTALLATION MANUAL. This Manual is to be left with owner. TUV Certificate of Design Approval
THE OXYVENT TANK Patent No. EP1264146 INSTALLATION MANUAL This Manual is to be left with owner TUV Certificate of Design Approval Oxyvent Limited, Headford, Killarney, Co. Kerry, Ireland Tel: +353-64-7754449
More informationheat interface units A BOILER WITHOUT A FLAME
A BOILER WITHOUT A FLAME heat interface units Communal Heat Networks A central boiler house will generate heat which is distributed through a network of pipe to each home or apartment in the building.
More informationRelated party disclosure: Technical Information Benchmark. 99 m² 336 kwh/m² per year 73 kg/m² per year
Energy Performance Certificate Northern Ireland 75 Mountsandel Road COLERAINE County Londonderry BT52 1JF Date of assessment: Date of certificate: Reference number: Accreditation scheme: Assessor's name:
More informationEnergy Efficiency Rating
Energy Performance Certificate Northern Ireland 49, Donard Avenue BANGOR BT20 3QD Date of assessment: 08 December 2017 Date of certificate: 08 December 2017 Reference number: 9663-0022-7739-7078-8902 Type
More informationYour Daikin Altherma remote controller
Your Daikin Altherma remote controller 2 3 1 4 1. Access home pages Switches between home pages for room temperature, tank temperature and leaving water temperature (when on the home pages) Goes to the
More informationContents.
Contents John Guest p 03/04 Introduction p 05 JG Aura 4 in 1 p 07 Features of 4 in 1 p 09/10 JG Aura App p 13/14 Wireless System p 15/16 Wireless TRV p 19/20 230v System p 23/24 Overview p 25 JG Speedfit
More informationBOILERMATE 2000 USER-GUIDE SWITCH. TEL: Gas Council Approved Reference Numbers
BOILERMATE 2000 USER-GUIDE SWITCH Gas Council Approved Reference Numbers BoilerMate 125 89-317-04A BoilerMate 145 89-317-05A BoilerMate 185 89-317-06A BoilerMate 210 89-317-07A BoilerMate 225 89-317-08A
More informationINFORMATION BOOKLET NRG Zone Models 2,3 and 4 Designed, Developed and Manufactured in Ireland
INFORMATION BOOKLET NRG Zone Models 2,3 and 4 Designed, Developed and Manufactured in Ireland Section 1 - Introduction THE NRG ZONE CENTRAL HEATING MANIFOLD This document will help you to understand the
More informationLeaseholder Energy Efficiency November 2011
Leaseholder Energy Efficiency November 2011 Contents: Energy Saving Tips Insulation White Goods Heating Grant Funding Fuel Switching Chris Moorhouse KNH 1 ENERGY SAVING TIPS Turn your thermostat down.
More informationTable 1: Hot water energy requirements
Table 1: Hot water energy requirements Floor area TFA (m 2 ) (a) Hot water usage V d (litres/day) (b) Energy content of water used (kwh/year) (c) Distribution loss (kwh/year) 30 63 1146 202 40 71 1293
More informationA 92 plus B C D E 39-54
Energy Performance Certificate Northern Ireland 21 Veryan Gardens NEWTOWNABBEY County Antrim BT36 7HG Date of assessment: 23 March 2010 Date of certificate: 24 March 2010 Reference number: 9780-0327-6420-8617-9926
More informationEnergy Efficiency Rating
Energy Performance Certificate Northern Ireland 44, Dunlady Manor Dundonald BELFAST BT16 1YP Date of assessment: 19 September 2017 Date of certificate: 20 September 2017 Reference number: 0578-2901-0311-9093-5415
More informationOxfordshire Community Groups & Volunteers. Top Tips. Compiled by Dale Hoyland, Strategic Development Manager, NEF
Oxfordshire Community Groups & Volunteers Top Tips Compiled by Dale Hoyland, Strategic Development Manager, NEF Tips on Heating and Hot Water Central Heating Systems Boiler The higher this is set, the
More informationDaikin Altherma Large Monobloc User Guide
Daikin Altherma Large Monobloc User Guide Your new Daikin Altherma heat pump In this guide you will find information and guidelines that will allow you to run your Daikin Altherma heat pump system in
More informationDaikin Altherma High Temperature User Guide
Daikin Altherma High Temperature User Guide Your new Daikin Altherma heat pump In this guide you will find information and guidelines that will allow you to run your Daikin Altherma heat pump system in
More informationControl Packs Catalogue. Including control packs compliant with 2013 Building Regulations: Part L
Control Packs Catalogue Including control packs compliant with 2013 Building Regulations: Part 1 Danfoss imited Ampthill Road Bedford MK42 9ER Reception Tel: 01234 364621 Fax: 01234 219705 UK Sales Tel:
More informationHEATBANK Xcel Thermal Store The solution to multi-fuel heating. Renewable Energy Solutions
HEATBANK Xcel Thermal Store The solution to multi-fuel heating Renewable Energy Solutions A Leading Supplier of Renewable Heat Products and Flue Systems 0333 999 7974 // www.specflue.com Suitable for simultaneous
More informationOutdoor Reset IQ Option Card, p/n
Outdoor Reset IQ Option Card, p/n 102723-01 Instruction Sheet CONTENTS Application... 1 General... 2 How it Works... 3 Installation.... 5 Wiring... 7 User Interface... 10 Using IQ Option Panel Display...
More informationPRECISION CONTROL FROM MYSON PLUS
THERMOSTATS PROGRAMMABLE ROOM THERMOSTATS PROGRAMMERS MOTORISED VALVES MYSON PLUS Eastern Avenue, Team Valley, Gateshead, Tyne & Wear NE11 0PG, UK T: 0845 402 3434, F: 0191 491 7568 TRVS PRECISION CONTROL
More informationBOSCH CONDENS 5000W ZSB18-2A
6720646195-00.1Wo HYDRONIC GAS SYSTEM BOILER 18kW BOSCH CONDENS 5000W ZSB18-2A Installation and Servicing Instructions 10 Boiler information AU/NZ 1 2 3 4 5 15 6 14 7 8 6720644743-04.1Wo 13 12 11 10 9
More informationFind out more visit speedfitufh.co.uk or call Take control with JG Aura Wireless TRV & Heating Controls. speedfitufh.co.
Find out more visit speedfitufh.co.uk or call 01895 9233 The JG Aura Wireless TRV head is compatible with a large number of TRVs such as Danfoss, Myson, Honeywell, Drayton, Altech and others. See our website
More informationARCHIVED DOCUMENT. houses - heating and hot water. Energy efficient refurbishment of public BEST PRACTICE PROGRAMME.
Energy efficient refurbishment of public houses - heating and hot water '\ ~ R,fc/, ':: 7 : : -;' IZ:I '".....0 (,c" ~ GH'" Energy Efficiency Office DEPARTMENT OF THE ENVIRONMENT, ' Upgrading heating systems
More informationWALL-HUNG HIGH EFFICIENCY GAS BOILERS
Heating Hot water Renewables GAS BOILERS E-COMBIevo E-SYSTEMevo CLAS HEevo CLAS HEevo system CLAS HE R WALL-HUNG HIGH EFFICIENCY GAS BOILERS Ariston a tradition that evolves For many years, we have entered
More informationTHERMAL STORE MAINS PRESSURE SYSTEM
THERMAL STORE MAINS PRESSURE SYSTEM Hot Water Storage Solutions Our THERMflow thermal store, works at the heart of your heating and hot water system to provide a high performance, mains pressure solution
More informationGreenstar 12i/24i System
USER INSTRUCTIONS & CUSTOMER CARE GUIDE Greenstar 12i/24i System WALL HUNG GAS-FIRED CONDENSING SYSTEM BOILER FOR SEALED CENTRAL HEATING SYSTEMS & INDIRECT FED DOMESTIC HOT WATER THIS BOILER IS USED WITH
More informationTORRENT STAINLESS ONE NAME. EVERY SOLUTION. OPEN VENTED THERMAL STORE PROVIDING HEATING AND MAINS PRESSURE HOT WATER
TORRENT STAINLESS OPEN VENTED THERMAL STORE PROVIDING HEATING AND MAINS PRESSURE HOT WATER ONE NAME. EVERY SOLUTION. WWW.GLEDHILL.NET WHAT IS A THERMAL STORE? A THERMAL STORE IS THE PERFECT SOLUTION FOR
More information24/31-28/35-33/40 kw Premix System Condensing - ErP Combi Gas Boilers. Enerwa / EnerwaPlus.
24/31-28/35-33/40 kw Premix System Condensing - ErP Combi Gas Boilers Enerwa / EnerwaPlus www.warmhaus.com Condensing-ErP Premix System Boilers 24/31-28/35-33/40 kw Warmhaus wall-hung gas combi boilers
More informationEnergy Performance Certificate
Energy Performance Certificate Northern Ireland 167, Killowen Grange, LISBURN, BT28 3JF Date of assessment: Date of certificate: Reference number: Type of assessment: Accreditation scheme: Assessor s name:
More informationHeating & Bathroom Supplies Merchants To The Trade
BOILER LIST MAY-JULY 2018 (WARRANTY IN BRACKETS) FREE BOTTLE OF HBS INHIBITOR OR PIPE SLICE (15 OR 22) WITH EVERY COLLECTED BOILER ECO RADIATORS = 79% DISCOUNT BARLO/TURBORAD RADIATORS = 83.5% DISCOUNT
More informationEnergy Performance Certificate
Energy Performance Certificate Northern Ireland 54, Tobarcooran Avenue, NEWTOWNABBEY, BT36 6EP Date of assessment: Date of certificate: Reference number: Type of assessment: Accreditation scheme: Assessor
More informationOaken Grove, Haxby, York, YO32 3QX
Oaken Grove, Haxby, York, YO32 3QX Oaken Grove, Haxby, York, YO32 3QX Asking Price: 250,000 OPEN DAY SATURDAY 26TH MAY 1PM TO 2PM - CALL TO BOOK YOUR SLOT - 3 BED SEMI DETACHED- HAXBY LOCATION NEAR SHOPS
More informationYour guide to. Biomass Heating Systems
Your guide to Biomass Heating Systems Biomass Boiler up to 70% savings on heating costs 1 TONNE OF FUSION PELLETS 7 Years Parts and Labour Warranty FREE * OPTION 1 FREE BOILER FREE biomass boiler FREE
More informationir-range 8G /03.15 Changes reserved.
U s e r m a n u a l ic-range is-range ir-range 8G.52.80.00/03.15 Changes reserved. Contents 1. Introduction...3 2. Safety...5 3. Boiler description...6 4. Display and functions...7 4.1 DHW and Heating
More informationGrant Aerona³. Air to Water High Efficiency Heat Pump Range. User Instructions
Grant Aerona³ Air to Water High Efficiency Heat Pump Range User Instructions UK DOC 0112 Rev 1.0 April 2017 Special Tex t Formats The following special text formats are used in this manual for the purposes
More informationDomestic heating solutions
Domestic heating solutions SYSTEM, COMBI AND OPEN VENT BOILERS \ WATER HEATERS \ UNVENTED CYLINDERS \ SOLAR THERMAL COLLECTORS \ AIR SOURCE HEAT PUMPS \ TRAINING For space and water heating Part of the
More informationSystem Installation. multi-zone heating
System Installation multi-zone heating Table of contents INTRODUCTION 1 Instructions guidance... 2 1.1 Product documentation...2 1.2 Associated documents...2 1.3 Explanation of symbols...2 1.4 Guarantee
More informationEnergy Efficiency Rating
Energy Performance Certificate Northern Ireland 9, Greenpark Road Rostrevor NEWRY BT34 3EY Date of assessment: 18 November 2017 Date of certificate: 19 November 2017 Reference number: 9289-3967-0219-7603-0910
More informationFrequently Asked Questions Solar Collector G24
Frequently Asked Questions Solar Collector G24 The installation and use of the collector is very simple. Here we have tried to answer the questions we get very comprehensively, for those who would like
More informationRETAIL PRICE LIST. season 2017/2018 valid from: April 18, INTELIGENTNE ROZWIĄZANIA
RETAIL PRICE LIST season 2017/2018 valid from: April 18, 2017 www.dksystem.pl INTELIGENTNE ROZWIĄZANIA Boiler controllers PRODUCT NAME APPLICATION PRICE WITHOUT VAT MASTER 600 SET cat. no. 504101 MASTER
More informationSmartRad Planning Manual
SmartRad Planning Manual Issue 1 15 April 2010 Dimplex SmartRad Fan Convector Models SRX80, SRX120, SRX140 & SRX180 Applies to models with White Glass, Black Glass and Metal facias Contents 1 Introduction
More informationVIESMANN. Operating instructions VITODENS VITOPEND. for the system user. Heating system with Vitotronic 100 control unit for constant temperature mode
Operating instructions for the system user VIESMANN Heating system with Vitotronic 100 control unit for constant temperature mode VITODENS VITOPEND 4/2007 Please keep safe. Safety instructions For your
More informationRecommendations texts (9.82) to be used on Energy Report in Scotland 18 July 2008
s texts (9.82) to be used on Energy Report in Scotland 18 July 2008 Note. The recommendations are picked up by software using the recommendation number (see SAP 2005 version 9.82, Appendix T). Where the
More informationSpring/Summer Incentives
Spring/Summer Incentives 2018 Welcome to our latest offers Whether you are installing a new high efficiency central heating system or a single appliance, there are so many great reasons to switch to natural
More informationSpring/Summer Incentives
Spring/Summer Incentives 2018 Welcome to our latest offers Whether you are installing a new high efficiency central heating system or a single appliance, there are so many great reasons to switch to natural
More informationA 92 plus B C D E F 21-38
Energy Performance Certificate Northern Ireland 5 Harmin Park NEWTOWNABBEY County Antrim BT36 7UR Date of assessment: 12 August 2010 Date of certificate: 17 August 2010 Reference number: 9929-1003-0238-6360-5964
More informationOutdoor Reset IQ Option Card, p/n
Outdoor Reset IQ Option Card, p/n 102723-01 Instruction Sheet CONTENTS Application... 1 General... 2 How it Works... 3 Installation.... 5 Wiring... 7 User Interface... 10 Using IQ Option Panel Display...
More informationYour Central Heating System
Your Central Heating System Heating guides online www.westwardhousing.org.uk/heating-guides Central heating systems generally mean a boiler heating cold water to circulate heat to radiators and also to
More informationModel: Touch-RF. 1 Wireless Series
Model: Touch-RF Model: Touch-RF 1 Wireless Series Table Of Contents Product Image 1 Locking the Keypad 18 Table of Contents 2 Temperature Control 19 What is a Programmable Room Thermostat? 3-4 Hot Water
More information- Application A Boiler Control 262 & One Stage Setpoint Control 150. Mechanical Remote Display Module (D1) 040 MODE 1
- Application Boiler Control & One Stage Setpoint Control 150 A -1 07/99 echanical Remote Display odule () 040 Outdoor Sensor () 070 150 ODE 1 Class II Transformer 120 V (ac) 24 V (ac) R1 A2 Z1 Z2 Z3 T1
More informationHeat emitters for Heat Pump systems. Bill Bucknell
Heat emitters for Heat Pump systems Bill Bucknell The Institute Founded in 1964 Systems incorporating circulating pumps needed for small-bore pipework Need careful design Entry into membership via one-year
More informationSystem Installation HYBRID BACK-UP
System Installation HYRID CK-UP TLE OF CONTTS INTRODUCTION 1 Instructions guidance... 2 1.1 Product documentation...2 1.2 ssociated documents...2 1.3 Explanation of symbols...2 1.4 Guarantee registration...2
More informationXcel HEATBANK Thermal Store The solution to multi-fuel heating. Renewable Energy Solutions
Xcel HEATBANK Thermal Store The solution to multi-fuel heating Renewable Energy Solutions Description of Standard Options Xcel HEATBANK Thermal Store Size and Capacity 01 02 The Xcel HEATBANK thermal store
More informationUnderstand and apply domestic central heating system installation and maintenance techniques
Level: 2 Credit value: 10 URN: Y/602/2888 Unit aim This combination unit provides basic learning in the installation, maintenance, decommissioning and soundness testing of a basic range of wet central
More information24/31-28/35-32/40 kw Premix System Condensing Combi Gas Boilers. Priwa / PriwaPlus
24/31-28/35-32/40 kw Premix System Condensing Combi Gas Boilers Priwa / PriwaPlus 1 Premix System Condensing Combi Gas Boilers 24/31-28/35-32/40 kw Warmhaus wall-hung gas combi boilers Priwa and PriwaPlus,
More informationChurch Street, Runcorn, WA7 1LA. Asking Price: 125,000
Church Street, Runcorn, WA7 1LA Three Bedrooms Period Town House Stunning Presentation Two Reception Rooms En - Suite and Four Piece Bathroom Sunny Rear Courtyard Ideal Family Home Integrated Appliances
More informationaquaplus High performance combination boiler with integrated power store
aquaplus High performance combination boiler with integrated power store Unrivalled performance The new aquaplus combination boiler with integrated power store is a new type of appliance, offering the
More informationEUROSTER 1100E USER MANUAL 1 EUROSTER 1100E
EUROSTER 1100E USER MANUAL 1 EUROSTER 1100E Congratulations on choosing our thermostatic controller EUROSTER. It is a technically advanced product which will serve you and your family for years bringing
More informationVIESMANN. Operating instructions VITODENS 100-W. for the system user
Operating instructions for the system user VIESMANN Heating system with control unit for constant temperature or weather-compensated mode VITODENS 100-W 1/2012 Please keep safe. Safety instructions For
More informationControls for domestic central heating and hot water guidance for specifiers and installers
GOOD PRACTICE GUIDE 302 Controls for domestic central heating and hot water guidance for specifiers and installers Controls for central heating systems with boilers and radiators, warm air units, or electric
More informationAquaCyl solar system solar water heating solution for the larger home with greater hot water demand (2 or more bathrooms in use simultaneously)
AquaCyl solar system solar water heating solution for the larger home with greater hot water demand (2 or more bathrooms in use simultaneously) solar collector AquaCyl cylinder system boiler Making life
More informationMAKING MODERN LIVING POSSIBLE. CP715Si. Electronic 2-Channel Common Timebase Programmer for Heating and Hot Water. User Guide.
MAKING MODERN LIVING POSSIBLE CP715Si Electronic 2-Channel Common Timebase Programmer for Heating and Hot Water Danfoss Heating User Guide CP715Si Electronic 2-Channel Common Timebase Programmer for Heating
More informatione 便 e 沈凜 y s 鹿 vi 便凜 ti 殺 s
e 便 e 沈凜 y s 鹿 vi 便凜 ti 殺 s 陋 y 凜 oo 勒 ene 沈凜 y Cooking and cleaning. Washing clothes and running the bath. All these day-to-day actions use up energy and make your carbon footprint bigger. But the good
More informationRT021 User and Installation Instructions
RT021 User and Installation Instructions Battery Operated Electronic Room Thermostat with TPI Temperature Control Software 1 2 The RT021 is a battery powered electronic room thermostat designed to provide
More informationCaleffi Hydronic Solutions Contact: Rex Gillespie, Director of Marketing Phone: (414)
Caleffi North America, Inc. 3883 W. Milwaukee Road Milwaukee, WI 53208 T: 414.238.2360 F: 414.238.2366 LITERATURE RELEASE Caleffi Hydronic Solutions June 10, 2010 Contact: Rex Gillespie, Director of Marketing
More informationHome Energy Saving Kit Take Home Booklet Simple tips to keep you saving
Home Energy Saving Kit Take Home Booklet Simple tips to keep you saving MEASURE, ACT, SAVE Now that you ve used the Home Energy Saving Kit, why not continue to enjoy savings by following our top tips in
More informationWHE 2.24 / WHE 2.24 FF
EN Wall-hung gas boilers WHE 2.24 WHE 2.24 FF User Guide 300011777-001-C . Contents 1 Introduction.............................................................................3 1.1 Symbols used...........................................................................................3
More informationSo old fashioned... As the combustion chamber is completely room sealed, it does not release any smells and does not dirty.
ARREDO E BENESSERE So old fashioned... An intelligent choice When on a cold winters night the warm glowing flames of the KALDUS boiler are there to welcome you back home, you will be pleased that you decided
More informationProduct Guide Oil-fired and solar thermal. heating and hot water solutions. Includes ErP ratings
Product Guide 2015 Oil-fired and solar thermal heating and hot water solutions Includes ErP ratings 1 The complete Worcester Greenstar oil-fired product range Our market-leading Greenstar oil-fired condensing
More informationturbomax plus High performance combination boiler range
turbomax plus High performance combination boiler range The winning combination High performance, simple installation and servicing are combined in the turbomax plus combination boiler range. Vaillant
More information