1 INTERNATIONAL JOURNAL OF PURE AND APPLIED RESEARCH IN ENGINEERING AND TECHNOLOGY A PATH FOR HORIZING YOUR INNOVATIVE WORK EXPERIMENTAL INVESTIGATION OF HELICAL COIL AND STRAIGHT TUBE HEAT EXCHANGER 1. Ph. D Scholar, Department of Mechanical Engineering 2. Prof. & HOD, Department of Mechanical Engineering SPECIAL ISSUE FOR NATIONAL LEVEL CONFERENCE "Technology Enabling Modernization of Rural India (TMRI- 2018) PRAVIN GAVADE 1, DR. NEERAJ KUMAR 2 Accepted Date: 19/03/2018; Published Date: 01/04/2018 Abstract: Heat exchangers are one of the key engineering apparatus used for transmitting heat from one liquid to another. Heat exchangers are commonly used in several types of application such as power plants, nuclear reactors, and refrigeration and air-conditioning systems, mechanical engineering. Helical coil structure is very effective for heat exchangers because they have a large heat transfer area in a small space, with great heat transfer coefficients validate to straight tube heat exchanger. The improved heat transfer coefficients are due to the curvature of the coil, which leads centrifugal forces to act on the fluid, which generates secondary flow. This paper emphasis on the Experimental investigation of helical coil heat exchanger and its study is carried out considering the various parameters such as flow rate of cold water, flow rate of hot water, temperature, effectiveness and overall heat transfer coefficient for both parallel flow and counter flow arrangement. Keywords: Helical Coil, Overall Heat Transfer Coefficient, Straight Tube, Effectiveness Etc. Corresponding Author: PRAVIN GAVADE PAPER-QR CODE Access Online On: How to Cite This Article: 224
2 INTRODUCTION A heat exchanger is known for transferring thermal energy among two or more liquids, at diverse temperatures and in thermal contact. Also the performance of the heat exchanger being enhanced, the heat transfer improvement enables the size of the heat exchanger to be significantly decreased. Helical coil heat exchangers are widely found in many industrial applications. The helically coiled tubes have advantage over straight tubes when working in heat transfer applications. In the coiled tube, the flow adjustment is due to centrifugal forces. The centrifugal forces are acting on the moving fluid due to the curvature ratio of the helical coil leads to the growth of Secondary flow which creates turbulence heat transfer rate increases. The amount of the centrifugal force depends upon axial velocity of flowing liquid and radius of curvature of the helical coil. HELICAL COIL GEOMETRY The diagram expresses different factors of the helical coil. Where, d= tube diameter, D= shell diameter, Rc = coil radius, b=helical coil pitch. Figure 1: Shell and helical coil heat exchanger. The material of helical coil tube is soft copper. The real helical coil is shown as below: Figure 2: Helical coil tube. 225
3 Factors of heat exchangers The different factors essential for heat exchanger are formulated beneath Sr. No. Dimensional factors Dimensions (mm) 1 Shell outside diameter [Do] Shell inside diameter [Di] Shell Thickness Outside tube diameter [do] Inside tube diameter [di] Tube thickness 0.40 EXPERIMENTAL METHOD AND FABRICATION A. Experimental Structure Figure 3 Experimental Structure Above figure demonstrates helical coil and straight coil heat exchanger. The set-up is heat transferring system in which a hot water flowing inside the tube-side is cooled by cold water flowing of outside tube. The key parts of the cycle are helical coiled tube heat exchanger, pump, storage tank, and heater. The heat exchangers contain a copper coiled tube and protected shell. The dimensions of the heat exchangers are given in Table. Electric heater is used to heat the water in storage tank. The hot water is permitted to pass through copper tubes by using 226
4 pump. Flow rate of hot water and cold water is controlled by valve. The inlet and outlet temperatures of hot and cold water were noted by using thermocouples in the inlet and outlet tubes. Also, all the pipes and connections between the temperature measuring stations and heat exchanger are duly insulated. o Constituents The different constituents required for Setup are listed below as per specification: 1. Helical coil tube: Material Copper Copper tube length 2 m Quantity 1 no. 2. Heater Specifications: Power Watt Voltage V AC/50 Hz 3. Pump: Pump Specification Power 18Watt Head m Speed rpm Discharge - LPH Volt - 220V 4. Thermocouples: For temperature of range 0 to 1200 degree Celsius. For quick response and ease of reading we used this thermometer. HELICAL COIL DESIGN The study of the helical coil heat exchanger is carried by following procedure: Step 1: Coil length (L) =π DC N Dc= m N=6.7 On Exchanging, L = 2 m Step 2: Curvature Ratio 227
5 δ= = Step 3: Pitch Ratio γ = = Step 4: Heat transfer rate: Q = mcp [ T] Where, Q = Heat transfer rate (kj s) m = mass flow rate of water (kg s) cp=specific heat of water ( J kgk) T= Temperature Difference [ ] Step 5. Logarithmic mean temp difference: = Where, Parallel flow: Counter flow: Tco are temperature differences = Inlet temperature of hot Water = Outlet temp of hot water = Inlet temperature of cold Water = Outlet temperature of cold water Step 6: Overall heat transfer coefficient: U = 228
6 Where, U = Overall heat transfer coefficient (W/m 2 ) Q = Heat transfer rate ( ) F = friction factor (1) A = Area of helical coil ( ) = LMTD ( ) Step 7: Effectiveness: Where, Effectiveness RESULT TABLE Result Tables for Helical coil heat exchanger in constant flow rate Helical coil heat exchanger (Constant mass flow rate in parallel flow): Sr. No Temp( ) (kg/s) Q (KJ/S) U (W/m 2 ) Helical coil heat exchanger (Constant mass flow rate in counter flow): Sr. No. Temp( ) (kg/s) Q (KJ/S) U (W/m 2 ) Result Tables for Straight tube heat exchanger in constant flow rate Straight tube heat exchanger [For constant mass flow rate in parallel flow] 229
7 Sr. No. Temp ( ) (kg/s) Q (KJ/S) U (W/m 2 ) Straight tube heat exchanger [For constant mass flow rate in counter flow] Sr. No. Temp ( ) (kg/s) Q (KJ/S) U (W/m 2 ) Result Tables for Helical coil heat exchanger for varying mass flow rate Helical coil heat exchanger: (varying mass flow rate in parallel flow) Sr. No. Temp( ) (kg/s) Q (KJ/S) U (W/m 2 ) Helical coil heat exchanger: (Varying mass flow rate in counter flow) Sr. No. Temp( ) (kg/s) Q (KJ/S) U (W/m 2 ) Result Tables for Straight tube heat exchanger in varying flow rate Straight tube heat exchanger for varying mass flow rate in parallel flow 230
8 Sr. No. Temp( ) (kg/s) Q (KJ/S) U (W/m 2 ) Straight tube heat exchanger for varying mass flow rate in counter flow Sr. No. Temp( ) (kg/s) Q (KJ/S) U (W/m 2 ) GRAPHS o Varying mass flow rate: Variation of Mass flow rate vs. Temperature drop Variation of heat transfer rate vs. mass flow rate 231
9 Variation of heat transfer coefficient vs mass flow rate Variation of effectiveness vs. mass flow rate o Constant mass flow rate: Temperature Vs. Overall Heat Transfer 232
10 Temperature Vs. Effectiveness: Temperature Vs heat transfer rate CONCLUSION The helical pipe has the greater surface so the time period of fluid contact with surface is greater which results into improved heat transfer compared to that of straight pipe. Effectiveness is greater in counter flow arrangement for both helical and straight heat exchangers compare to parallel flow arrangement. When temperature increases there is a slow rise in the heat transfer rate in both straight tube and helical coil but it is extreme in helical coil. Also effectiveness increases by temperature increases and decreases when mass flow rate is increased. The temperature drop for helical coiled tube is higher than the straight tube. From this experimental investigation for same space and volume in industry the helical heat exchangers are more efficient than normal straight heat exchangers. REFERENCE 1. N. D. Shirgire (2014), Comparative Study and Analysis between Helical Coil and Straight Tube Heat Exchanger International Journal of Engineering Research & Technology (IJERT) Vol 4 Issue Pramod S. Purandare, Mandar M. Lele, Rajkumar Gupta (2012), Parametric Analysis of Helical Coil Heat Exchanger International Journal of Engineering Research & Technology (IJERT) Vol. 1 Issue
11 3. B. ChinnaAnkanna, B. Sidda Reddy (2014), Performance Analysis of Fabricated Helical Coil Heat Exchanger International Journal of Engineering Research, Volume No.3 Issue No: Special 1, pp: Mr. Dhiraj D. Shinde (2015), Experimental Study of Heat Transfer Parameters using internal threaded pipe fitted with inserts of different materials International Journal of Engineering Research & Technology (IJERT) Vol. 1 Issue MadhuriTayde (dec2014), Heat Transfer Analysis of a Helically Coiled Heat Exchange International Journal of Engineering Research & Technology (IJERT) Vol 4 Issue Namrata D. Ranaware (2015), A Review on Comparison between Shell and Tube Heat Exchanger and Helical Coil Heat Exchanger International Journal of Engineering Research & Technology (IJERT vol 2 Issue 2). 7. Swapnil Ahire (2015), Fabrication and Analysis of Counter Flow Helical Coil Heat Exchanger International Journal of Engineering Research & Technology (IJERT) Vol Shiva Kumara (2013), Numerical Analysis of a Helical Coiled Heat Exchanger using CFD International Journal of Engineering Research & Technology (IJERT) vol
INTERNATIONAL JOURNAL OF PURE AND APPLIED RESEARCH IN ENGINEERING AND TECHNOLOGY
INTERNATIONAL JOURNAL OF PURE AND APPLIED RESEARCH IN ENGINEERING AND TECHNOLOGY A PATH FOR HORIZING YOUR INNOVATIVE WORK SPECIAL ISSUE FOR NATIONAL LEVEL CONFERENCE "RENEWABLE ENERGY RESOURCES & IT S
More informationPerformance Study of Triple Concentric Pipe Heat Exchanger
Performance Study of Triple Concentric Pipe Heat Exchanger #1 Pravin M. Linge, #2 A. B. Korane, #3 V. N. Kapatkar #123 Mechanical Engineering Department, Sinhgad College of Engineering, SPPU, Pune, India
More informationExperimental study on heat transfer characteristics of horizontal concentric tube using twisted wire brush inserts
International Journal of Current Engineering and Technology E-ISSN 2277 416, P-ISSN 2347 5161 216 INPRESSCO, All Rights Reserved Available at http://inpressco.com/category/ijcet Research Article Experimental
More informationijcrr Vol 04 issue 07 Category: Research Received on:06/02/12 Revised on:17/02/12 Accepted on:02/03/12
EXPERIMENTAL ANALYSIS OF THE EFFECT OF FIN GEOMETRY ON HEAT TRANSFER RATE THROUGH THE REFRIGERATOR CONDENSER ijcrr Vol 04 issue 07 Category: Research Received on:06/02/12 Revised on:17/02/12 Accepted on:02/03/12
More informationFeasibility Study of Condensation Heat Exchanger with Helical Tubes for a Passive Auxiliary Feedwater System
Feasibility Study of Condensation Heat Exchanger with Helical Tubes for a Passive Auxiliary Feedwater System Kwanghee Seo 1) and Taewan Kim 2)* 1) KEPCO Engineering & Construction Company. INC., 269 Hyeoksin-ro,
More informationPerformance Analysis of Li-Br Water Refrigeration System with Double Coil Anti-Swirl Shell and Coil Heat Exchangers
e-issn 2455 1392 Volume 2 Issue 5, May 2016 pp. 108-116 Scientific Journal Impact Factor : 3.468 http://www.ijcter.com Performance Analysis of Li-Br Water Refrigeration System with Double Coil Anti-Swirl
More informationEnhancement of COP in Vapour Compression Refrigeration System
Enhancement of COP in Vapour Compression Refrigeration System M. Krishna Prasanna #1 M.E student, Heat Transfer studies in Energy Systems Department of Mechanical Engg., Andhra University Visakhapatnam-530003,
More informationDesign & Development of Tube in Tube Helical Coil Heat Exchanger
Int. Res. J. of Science & Engineering, 2018; Special Issue A2 : 245-250 SJIF Impact Factor 4.11 ISSN: 2322-0015 UGC Approved Journal No. 63628 RESEARCH ARTICLE OPEN ACCESS Design & Development of Tube
More informationSant Gadge Baba Amravati University. Amravati, Maharashtra, India, Maharashtra 2
2018 IJSRST Volume 4 Issue 8 Print ISSN: 2395-6011 Online ISSN: 2395-602X Themed Section: Science and Technology Heat Transfer Characteristic of Spiral Heat Exchanger: Effect of Reynolds Number on Heat
More informationAn Experimental Study of a Simple Vapour Compression Refrigeration System with Varying Parameters
An Experimental Study of a Simple Vapour Compression Refrigeration System with Varying Parameters #1 Harshad D Kopurwar, #2 Pravin T Nitnaware, #3 Tapobrata Dey 1 harshvardhan1590@gmail.com #1 Mechanical
More informationExperimental performance evaluation of heat pump by using CO 2. as a refrigerant. IOP Conference Series: Materials Science and Engineering
IOP Conference Series: Materials Science and Engineering PAPER OPEN ACCESS Experimental performance evaluation of heat pump by using CO 2 as a refrigerant To cite this article: V K Venkatesh et al 2016
More informationHEAT TRANSFER ENHANCEMENT IN SHELL AND TUBE HEAT EXCHANGERS USING INSERTS
International Journal of Mechanical Engineering and Technology (IJMET) Volume 8, Issue 10, October 2017, pp. 180 184, Article ID: IJMET_08_10_022 Available online at http://www.iaeme.com/ijmet/issues.asp?jtype=ijmet&vtype=8&itype=10
More information[Jhansi, 5(10): October 2018] ISSN DOI /zenodo Impact Factor
GLOBAL JOURNAL OF ENGINEERING SCIENCE AND RESEARCHES PERFORMANCE ANALYSIS OF VCR SYSTEM WITH TWISTED TAPE CONDENSER BY USING R134a REFRIGERANT Chidige Jhansi* 1 & Dr.Smt.G.Prasanthi 2 *1 PG Research Scholar
More informationExperimental Analysis of Performance Characteristics of Mini Channel Heat Exchangers
Experimental Analysis of Performance Characteristics of Mini Channel Heat Exchangers Ashraf A 1, Mohammed Shan N 2, Thoufeeq Azad 3, Bibin S4, Arun S 5 1-4 Students, 5 Assistant Professor Department of
More informationHeat Transfer Enhancement using Herringbone wavy & Smooth Wavy fin Heat Exchanger for Hydraulic Oil Cooling
Enhancement using Herringbone wavy & Smooth Wavy fin Exchanger for Hydraulic Oil Cooling 1 Mr. Ketan C. Prasadi, 2 Prof. A.M. Patil 1 M.E. Student, P.V.P.I.T.,Budhagaon,Sangli AP-India 2 Associate Professor,
More informationExperimental Study And CFD Based Simulation of Closed Loop Pulsating Heat Pipe Using of Refrigerants (R-134a)
International OPEN ACCESS Journal Of Modern Engineering Research (IJMER) Experimental Study And CFD Based Simulation of Closed Loop Pulsating Heat Pipe Using of Refrigerants (R-134a) Monika Tiwari 1, Dr.
More informationDesign, Development & Testing of Double Pipe Heat Exchanger With Heat Transfer Enhancement Liners
Volume 2, Issue 1, January 2017 ISSN (online): 2456-0006 International Journal of Science Technology Management and Research Available online at: Design, Development & Testing of Double Pipe Heat Exchanger
More informationA Generalized Correlation for Pressure Drop of Refrigerant R-134a through Helical Capillary Tubes
ISSN 2395-1621 A Generalized Correlation for Pressure Drop of Refrigerant R-134a through Helical Capillary Tubes #1 N. Dhekale, #2 Dr. P. A. Patil 1 amardhekale@gmail.com #12 Research Laboratory, Department
More informationPerformance Analysis Of Double Inclination Ribbed Solar Air Heater Rectangular Duct By Liquid Crystal Thermography
Performance Analysis Of Double Inclination Ribbed Solar Air Heater Rectangular Duct By Liquid Crystal Thermography Amit Kumar Gautam¹, Dr. J. L. Bhagoria² ¹M.Tech. Scholar, Mechanical Engineering, ²Professor,
More informationINTERNATIONAL JOURNAL OF PURE AND APPLIED RESEARCH IN ENGINEERING AND TECHNOLOGY
INTERNATIONAL JOURNAL OF PURE AND APPLIED RESEARCH IN ENGINEERING AND TECHNOLOGY A PATH FOR HORIZING YOUR INNOVATIVE WORK AUTOMATIC WHITE BOARD ERASER PRANIL SAWALAKHE 1, ADITYA KUMAR SINGH 2, TAPASH PANDA
More informationANALYSING THE EFFECTIVENESS OF THE HEAT EXCHANGER BY INCREASING OVERALL HEAT TRANSFER COEFFICIENT
ANALYSING THE EFFECTIVENESS OF THE HEAT EXCHANGER BY INCREASING OVERALL HEAT TRANSFER COEFFICIENT Mazhar Mumbaiwala 1, Rahul Panjwani 2, Rishikesh Shulav 3, Shashwat Budholia 4, Anshu Kumar 5 1,2,3,4UG
More informationPerformance Evaluation of VCRS with Nested Helical Shaped Condenser by Using R134a as Refrigerant
Performance Evaluation of VCRS with Nested Helical Shaped Condenser by Using R134a as Refrigerant Bukke Bhagyalathamma 1, Dr.Smt.G.Prasanthi 2 Department 1,2,Department of Mechanical Engineering,PG Scholor
More informationEFFECTS OF VARIABLES ON NATURAL CONVECTIVE HEAT TRANSFER THROUGH V-CORRUGATED VERTICAL PLATES
International Journal of Mechanical and Materials Engineering (IJMME), Vol. 2 (2007), No. 2, 109--117. EFFECTS OF VARIABLES ON NATURAL CONVECTIVE HEAT TRANSFER THROUGH V-CORRUGATED VERTICAL PLATES M. Hasanuzzaman
More informationDesign and Development of Water Cooled Condenser for Domestic Refrigerator
Design and Development of Water Cooled Condenser for Domestic Refrigerator Anil S. Patil Research PG Student, GF s Godavari College of Engineering, Jalgaon Dr. Atul A Patil Assot. Prof. GF s Godavari College
More informationEnhancement of COP by Using Spiral and Microchannel Condenser instead of conventional Condenser of VCR System
Enhancement of COP by Using Spiral and Microchannel instead of conventional of VCR System 1 P.G. Lohote, 2 Dr.K.P. Kolhe. 1 P.G. Student, 2 Professor. 1,2 Department of Mechanical Engineering, JSPM s,
More informationAnalysis of a Condenser in a Thermal Power Plant for Possible Augmentation in its Heat Transfer Performance
Analysis of a Condenser in a Thermal Power Plant for Possible Augmentation in its Heat Transfer Performance P Vamshi Krishna 1, Hemasunder Banka 2, S.Rama 3, Ch. Jeevan Reddy 4, G.Venkanna 5 1,2,3,4,5,
More informationTITLE: Improvement in Heat Transfer Rate and Dynamics of Shrouded Fanned Radiator System
TITLE: Improvement in Heat Transfer Rate and Dynamics of Shrouded Fanned Radiator System Prof. G.L.Allampallewar 1, Divyal P. Bagul 2, Abhiraj S. Galande 3, Amol M. Rathod 4, Ketan R. Behere 5. 1 Assistant
More information"COP Enhancement Of Domestic Refrigerator By Sub cooling And Superheating Using Shell &Tube Type Heat Exchanger"
"COP Enhancement Of Domestic Refrigerator By Sub cooling And Superheating Using Shell &Tube Type Heat Exchanger" 1 Prof.Gaffar G.Momin, 2 Sagar B. Tupe, 2 Swapnil A. Parate 2 Omkar G. Yewale 2 Aakash P.
More informationExperimental Investigation of a Brazed Chevron Type Plate Heat Exchanger
IJSTE - International Journal of Science Technology & Engineering Volume 1 Issue 12 June 2015 ISSN (online): 2349-784X Experimental Investigation of a Brazed Chevron Type Plate Heat Exchanger N. Manigandan
More information[Vali*, 5(2): February, 2016] ISSN: (I2OR), Publication Impact Factor: 3.785
IJESRT INTERNATIONAL JOURNAL OF ENGINEERING SCIENCES & RESEARCH TECHNOLOGY PERFORMANCE ANALYSIS OF VCR SYSTEM WITH VARYING THE DIAMETERS OF HELICAL CONDENSER COIL BY USING R-134A REFRIGERANT R.Hussain
More information2. HEAT EXCHANGERS MESA
1. INTRODUCTION Multiport minichannel and microchannel aluminium tubes are becoming more popular as components in heat exchangers. These heat exchangers are used in various industrial applications and
More informationEXPERIMENTAL INVESTIGATION ON SHELL AND TUBE HEAT EXCHANGER USING SEGMENTAL AND DISC-DOUGHNUT TYPE BAFFLES
International Journal of Mechanical Engineering and Technology (IJMET) Volume 8, Issue 12, December 2017, pp. 975 984, Article ID: IJMET_08_12_106 Available online at http://www.iaeme.com/ijmet/issues.asp?jtype=ijmet&vtype=8&itype=12
More informationExperimental Analysis of Heat Exchanger and Simulation of Result Using Solid Works Software
Experimental Analysis of Heat Exchanger and Simulation of Result Using Solid Works Software Mukul Sangwan 1, Manpreet Singh 2 1 Student Department of Mechanical Engineering, RIEM College Rohtak, Haryana
More informationStudy of R-161 refrigerant as an Alternate Refrigerant to various other refrigerants
International Journal of Current Engineering and Technology E-ISSN 2277 4106, P-ISSN 2347 5161 2016 INPRESSCO, All Rights Reserved Available at http://inpressco.com/category/ijcet Research Article Study
More informationThermal Design of Condenser Using Ecofriendly Refrigerants R404A-R508B for Cascade Refrigeration System
Thermal Design of Condenser Using Ecofriendly Refrigerants R404A-R508B for Cascade Refrigeration System A D Parekh, and P R Tailor Abstract Because of damaging effect of CFC refrigerants on stratospheric
More informationSTUDY OF HEAT TRANSFER IN A CORRUGATED PLATE HEAT EXCHANGER USING AL 2 O 3 MICROPARTICLES
International Journal of Mechanical Engineering and Technology (IJMET) Volume 7, Issue 4, July Aug 216, pp.189 195, Article ID: IJMET_7_4_19 Available online at http://www.iaeme.com/ijmet/issues.asp?jtype=ijmet&vtype=7&itype=4
More informationII. OBJECTIVE OF RESEARCH
Enhancement of Coefficient of Performance of Vapor Compression Refrigeration System Using Diffuser at let of Condenser Mr. Nurul Seraj 1, Dr. S. C. Roy 2 1 Student, 2 Head of Department, Department of
More informationExperimental Investigation of Elliptical Tube Bank Cross Flow Heat Exchanger with Inline Arrangement & 45 Angle of Attack
Experimental Investigation of Elliptical Tube Bank Cross Flow Heat Exchanger with Inline Arrangement & 45 Angle of Attack #1 Digvijay A. Shelar, #2 N.S. Gohel, #3 R. S. Jha #1 Mechanical Engineering Department,
More informationGandhinagar Institute of Technology Mechanical Engineering (Thermal Engineering) Semester II. Design of Heat Exchange Equipments [ ]
Experiment 1 Study of fundamentals of Fluid Flow and Heat Transfer associated with Heat Exchangers Review questions (1) Significance of dimensionless numbers. (2) Define overall heat transfer coefficient.
More informationSolar air heater duct having triangular protrusions As roughness elements on absorber plate
Solar air heater duct having triangular protrusions As roughness elements on absorber plate A. Nagaraju 1, B. Chnadramohan Reddy 2 1,2 Department of Mechanical Engineering, Jawaharlal Nehru Technological
More informationWaghmare Tushar Ramrao, D.S.Nakate
International Engineering Research Journal Performance analysisof vapor compression system by using capillary tube suction line heat exchanger and helical condenser for R134a Waghmare Tushar Ramrao, D.S.Nakate
More informationPERFORMANCE OF VCRS SYSTEM WITH HEAT EXCHANGER AND PHASE CHANGE MATERIAL
PERFORMANCE OF VCRS SYSTEM WITH HEAT EXCHANGER AND PHASE CHANGE MATERIAL K.Thejeswarudu 1, R. Meenakshi Reddy 2 and E. Siva Reddy 2 1 PG Student, Department of Mechanical Engineering, G. Pulla Reddy College
More informationHEFAT th International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics Sun City, South Africa Paper number:pp1
HEFAT27 5 th International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics Sun City, South Africa Paper number:pp PERFORMANCE ANALYSIS OF AIR-COOLED CONDENSER USING MICRO-FIN TUBES P.A.Patil
More informationEffects of Volute Tongue Clearance and Rotational Speed on Performance of Centrifugal Blower Nitin S. Jadhav *, S. R. Patil
2016 IJSRSET Volume 2 Issue 4 Print ISSN : 2395-1990 Online ISSN : 2394-4099 Themed Section: Engineering and Technology Effects of Volute Tongue Clearance and Rotational Speed on Performance of Centrifugal
More informationExperimental analysis of condensation heat transfer enhancement of steam at low pressures using modified twisted tape insert
International Journal of Current Engineering and Technology E-ISSN 2277 4106, P-ISSN 2347 5161 2016 INPRESSCO, All Rights Reserved Available at http://inpressco.com/category/ijcet Research Article Experimental
More informationEXPERIMENTAL ANALYSIS OF TIP CLEARANCE AND CHORD LENGTH FOR OPTIMUM DESIGN OF AXIAL FLOW FAN IN AIR COOLED HEAT EXCHANGER
EXPERIMENTAL ANALYSIS OF TIP CLEARANCE AND CHORD LENGTH FOR OPTIMUM DESIGN OF AXIAL FLOW FAN IN AIR COOLED HEAT EXCHANGER Sushil Kumar 1, Dr. V.N.Bartaria 2 1 M.Tech Scholar, 2 Professor & HOD Dept. of
More informationCFD Analysis of a 24 Hour Operating Solar Refrigeration Absorption Technology
IJIRST International Journal for Innovative Research in Science & Technology Volume 1 Issue 11 April 2015 ISSN (online): 2349-6010 CFD Analysis of a 24 Hour Operating Solar Refrigeration Absorption Technology
More informationExperimental Comparison of Natural Convection Heat Transfer from a Blackened V-Fin Array
International Journal of Modern Studies in Mechanical Engineering (IJMSME) Volume 4, Issue 1, 2018, PP 11-16 ISSN 2454-9711 (Online) DOI: http://dx.doi.org/10.20431/2454-9711.0401002 www.arcjournals.org
More informationSTUDY, ANALYSIS AND DESIGN OF AUTOMOBILE RADIATOR (HEAT EXCHANGER) PROPOSED WITH CAD DRAWINGS AND GEOMETRICAL MODEL OF THE FAN
International Journal of Mechanical and Production Engineering Research and Development (IJMPERD) ISSN 2249-6890 Vol. 3, Issue 2, Jun 2013, 137-146 TJPRC Pvt. Ltd. STUDY, ANALYSIS AND DESIGN OF AUTOMOBILE
More informationCHAPTER 7 COMPARISON OF HEAT EXCHANGERS
168 CHAPTER 7 COMPARISON OF HEAT EXCHANGERS Heat exchangers may be classified according to their flow arrangement. In parallel flow heat exchangers, the two fluids enter the exchanger at the same end,
More informationa Heat Exchanger using FEA Tool
A Review on Optimal Design of Single Tube in a Heat Exchanger using FEA Tool Roshan V. Marode Abstract:- The performance of heat exchangers can be improved to perform a certain heat-transfer duty by heat
More informationJava Development Program on Parallel and Counter Flow Heat Exchanger
Java Development Program on Parallel and Counter Flow Heat Exchanger Mr. Tanmay Sahuji 1 Dept of Mechanical Engineering Walchand Institute of Technology (WIT), Solapur, India. Mr. Pritish Chitte 3 Assistant
More informationAnalysis of Constant Pressure and Constant Area Mixing Ejector Expansion Refrigeration System using R-1270 as Refrigerant
Analysis of Constant Pressure and Constant Area Mixing Ejector Expansion Refrigeration System using R-1270 as Refrigerant Ravi Verma 1, Sharad Chaudhary 2 1, 2 Department of Mechanical Engineering, IET
More informationINTERNATIONAL JOURNAL OF MECHANICAL ENGINEERING AND TECHNOLOGY (IJMET) AN EXPERIMENTAL STUDY OF HEAT TRANSFER IN A CORRUGATED PLATE HEAT EXCHANGER
INTERNATIONAL JOURNAL OF MECHANICAL ENGINEERING AND TECHNOLOGY (IJMET) International Journal of Mechanical Engineering and Technology (IJMET), ISSN 0976 6340(Print), ISSN 0976 6340 (Print) ISSN 0976 6359
More informationModeling and Simulation of Axial Fan Using CFD Hemant Kumawat
Modeling and Simulation of Axial Fan Using CFD Hemant Kumawat Abstract Axial flow fans, while incapable of developing high pressures, they are well suitable for handling large volumes of air at relatively
More informationDesign and Experimental Analysis of Concentric Tube Heat Exchangers with Various Fins
Design and Experimental Analysis of Concentric Tube Heat Exchangers with Various Fins K.Saravanakumar 1, N.Sivakumar 2, R.Rajesh 3, S. Selvakumar 4, R.Sivasankar 5 B.E, Dept. of Mechanical Engineering,
More informationA Study of Heat Transfer Using Corrugated Al 2 o 3 microparticles
International Refereed Journal of Engineering and Science (IRJES) ISSN (Online) 2319-183X, (Print) 2319-1821 Volume 4, Issue 6 (June 2015), PP.110-115 A Study of Heat Transfer Using Corrugated Al 2 o 3
More informationNumerical Studies On The Performance Of Methanol Based Air To Air Heat Pipe Heat Exchanger
International Journal of ChemTech Research CODEN( USA) IJCRGG ISSN 0974-4290 Vol.5, No.2, pp 925-934, April-June 2013 ICGSEE-2013[14th 16th March 2013] International Conference on Global Scenario in Environment
More informationPERFORMANCE ANALYSIS OF VAPOUR COMPRESSION THERMOELECTRIC REFRIGERATION SYSTEM WITH NOZZLE AND DIFFUSER THROUGH INCORPORATION OF PHASE CHANGE MATERIAL
International Journal of Technical Innovation in Modern Engineering & Science (IJTIMES) Impact Factor: 3.45 (SJIF-2015), e-issn: 2455-2585 Volume 3, Issue 10, October-2017 PERFORMANCE ANALYSIS OF VAPOUR
More informationThermal Analysis of Concentric Tube Heat Exchanger Using Louvered Strip Inserts
Thermal Analysis of Concentric Tube Heat Exchanger Using Louvered Strip Inserts Anoop P S 1, N. Sreenivasalu Reddy 2 1 PG scholar, Raja Rajarajeswari College of Engineering, Bangalore-560074, Karnataka,
More informationInternational Journal of Engineering Research & Technology (IJERT) ISSN: Vol. 2 Issue 10, October
Thermodynamic and Hydrodynamic Performance of Double Pipe Heat Exchanger with Bended Strips Prof. S. S. Rajigare, Prof. H. M. Dange Assistant professor at KJCOEMR Pune, Professor PVPIT Sangli Abstract
More informationMINIATURE HEAT TRANSPORT SYSTEMS WITH LOOP HEAT PIPES
IV Minsk International Seminar Heat Pipes, Heat Pumps, Refrigerators Minsk, Belarus, September 4-7, MINIATURE HEAT TRANSPORT SYSTEMS WITH LOOP HEAT PIPES V. Kiseev, A. Belonogov Ural State University,
More informationEXPERIMENTAL VERIFICATION OF PERFORMANCE OF CAPILLARY TUBE USING VAPOUR COMPRESSION REFRIGERATION SYSTEM
EXPERIMENTAL VERIFICATION OF PERFORMANCE OF CAPILLARY TUBE USING VAPOUR COMPRESSION REFRIGERATION SYSTEM Prof. S.V.Rao 1, Hitesh Sharma 2, Pankaj Kumar Gound 3, Tukaram Walgude 4, Shekhar Gavas 5 1 Prof.
More informationPerformance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger
Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger Abstract Shoeb J. Inamdar 1 H.S. Farkade 2 M. Tech student. (Thermal Engineering) 1, Asst. Professor 2 Department of Mechanical
More informationDESIGN, ANALYSIS AND FABRICATION OF THERMOELECTRIC COOLING AND HEATING SYSTEM FOR WATER DISPENSER
DESIGN, ANALYSIS AND FABRICATION OF THERMOELECTRIC COOLING AND HEATING SYSTEM FOR WATER DISPENSER R.S.Fayazahamed 1, S.CyrilJain 2, K.L.Alagarasan 3, A.Balachandran 4, P.Balasubramani 5 1,2,3,4 UG Students,
More informationPERFORMANCE EVALUATION OF TWO STAGE AIR COOLER IN DIFFERENT SPEED
International Journal of Mechanical Engineering and Technology (IJMET) Volume 7, Issue 3, May June 2016, pp.329 341, Article ID: IJMET_07_03_030 Available online at http://www.iaeme.com/ijmet/issues.asp?jtype=ijmet&vtype=7&itype=3
More informationPerformance of R-22, R-407C and R-410A at Constant Cooling Capacity in a 10
Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2000 Performance of R-22, R-407C and R-410A at Constant Cooling Capacity in
More informationIJSRD - International Journal for Scientific Research & Development Vol. 4, Issue 04, 2016 ISSN (online):
IJSRD - International Journal for Scientific Research & Development Vol. 4, Issue 04, 2016 ISSN (online): 2321-0613 Design of Compact Condenser for Waste Heat Recovery and Cop Enhancement of Refrigerator
More informationWASTE HEAT RECOVERY FROM DOMESTIC REFRIGERATOR Soma A. Biswas 1, Sandeep M. Joshi 2 1,2 Pillai College of Engineering
WASTE HEAT RECOVERY FROM DOMESTIC REFRIGERATOR Soma A. Biswas 1, Sandeep M. Joshi 2 1,2 Pillai College of Engineering Abstract Refrigeration is a process where the heat moves from low temperature reservoir
More informationKeywords: Triple tube heat exchanger (TTHE), hot water, cold water, CFD simulation.
International Engineering Research Journal Design and CFD analysis of concentric triple tube heat exchanger with circular fins Girishkumar Patil, Prof.S.K.Bhosale and Prof.V.S.Shinde ϯ ϯ Abstract The triple
More informationRole of Nano-technology for improving of thermal performances of vapour compression refrigeration system (VCRS): An Overview
International Journal of Research in Engineering and Innovation Vol-2, Issue-1 (2018), 21-28 International Journal of Research in Engineering and Innovation (IJREI) journal home page: http://www.ijrei.com
More informationPERFORMANCE ANALYSIS AND CALCULATION OF DIFFERENT PARAMETERS OF CONDENSER USING ANSYS FLUENT SOFTWARE
PERFORMANCE ANALYSIS AND CALCULATION OF DIFFERENT PARAMETERS OF CONDENSER USING ANSYS FLUENT SOFTWARE Ram Mohan Gupta 1, Dr. Shatyendra Singh 2 Mr. Simant Srivastava 3 1 Mechanical Engineering, Uttarakhand
More informationPressure drop analysis of evaporator using refrigerants R-22, R-404A and R-407C
drop analysis of evaporator using refrigerants R-22, R-404A and R-407C #1 Pallavi Sawkar, #2 Dr. Pradeep Patil #12 Department of Mechanical Engineering, JSPM s JSCOE, Savitribai Phule Pune University,
More informationANKUSH SHARMA & JAGDEV SINGH Department of Mechanical Engineering, Beant College of Engineering and Technology, Gurdaspur, Punjab, India
International Journal of Mechanical and Production Engineering Research and Development (IJMPERD) ISSN 2249-6890 Vol. 3, Issue 1, Mar 2013, 85-94 TJPRC Pvt. Ltd. EXPERIMENTAL INVESTIGATION OF REFRIGERANT
More informationDynamic Simulation of Double Pipe Heat Exchanger using MATLAB simulink
Dynamic Simulation of Double Pipe Heat Exchanger using MATLAB simulink 1 Asoka R.G, 2 Aishwarya N, 3 Rajasekar S and 4 Meyyappan N 1234 Department of Chemical Engineering Sri Venkateswara College of Engineering,
More informationHEAT TRANSFER COEFFICIENT ENHANCEMENT IN NATURAL CONVECTION FROM HORIZONTAL RECTANGULAR FIN ARRAYS WITH PERFORATIONS
International Journal of Mechanical Engineering and Technology (IJMET) Volume 10, Issue 01, January 2019, pp. 306 315, Article ID: IJMET_10_01_031 Available online at http://www.iaeme.com/ijmet/issues.asp?jtype=ijmet&vtype=10&itype=1
More informationPerformance of Shell and Tube Heat Exchanger under Varied Operating Conditions
Performance of Shell and Tube Heat Exchanger under Varied Operating Conditions N. Prabhu Kishore 1, N. Alekhya 2, J. Ugandhar 3 Asst. Professor, Department of Mechanical Engineering, MLR Institute of Technology,
More informationExperiment 12 Shell and Tube Heat Exchanger. Aim of this Experiment
Experiment 12 Shell and Tube Heat Exchanger Aim of this Experiment The shell and tube exchanger is a simple model that demonstrates the basic principles of heat transfer consists of a number of tubes in
More informationAnalysis of Evaporative Cooler and Tube in Tube Heat Exchanger in Intercooling of Gas Turbine
IJIRST International Journal for Innovative Research in Science & Technology Volume 1 Issue 11 April 2015 ISSN (online): 2349-6010 Analysis of Evaporative Cooler and Tube in Tube Heat Exchanger in Intercooling
More informationExperimental Analysis of Open, Simple and Modified Greenhouse Dryers for Drying Potato Flakes under Forced Convection
RESEARCH ARTICLE OPEN ACCESS Experimental Analysis of Open, Simple and Modified Greenhouse Dryers for Drying Potato Flakes under Forced Convection Tanuj Kumar Sahu 1, Vishal Gupta 2, Ajay Kumar Singh 3
More informationDESIGN AND ANALYSIS OF PIPE HEAT EXANGERS WITH INSIDE FINS
DESIGN AND ANALYSIS OF PIPE HEAT EXANGERS WITH INSIDE FINS Helan Jacob.J 1,Chandra Mohan.B 2,Palanisamy.S 3 1, P.G. Scholars, Department ofthermal Engineering, Oxford Engineering college,pratiyur, Trichy.
More informationIMPROVE THE EFFICIENCY OF HEAT EXCHANGER IN OIL COOLER.
IMPROVE THE EFFICIENCY OF HEAT EXCHANGER IN OIL COOLER. PARMAR NAVIN J (D11ME09) PRAJAPATI JAIMIN R (10ME41) PATEL DEEP K (10ME56) INTERNAL GUIDE:- DIXIT M PATEL ABSTRACT For shell-and-tube oil cooler
More informationPerformance Comparison of Ejector Expansion Refrigeration Cycle with Throttled Expansion Cycle Using R-170 as Refrigerant
International Journal of Scientific and Research Publications, Volume 4, Issue 7, July 2014 1 Performance Comparison of Ejector Expansion Refrigeration Cycle with Throttled Expansion Cycle Using R-170
More informationVORTEX TUBE REFRIGERATION SYSTEM BASED ON COMPRESSED AIR
International Journal of Mechanical Engineering and Technology (IJMET) Volume 6, Issue 7, July 2015, pp. 97-102, Article ID: 30120150607012 Available online at http://www.iaeme.com/currentissue.asp?jtype=ijmet&vtype=6&itype=7
More informationHeat Transfer Analysis of Vapor Compression System Using Nano Cuo-R134a
2011 International Conference on Advanced Materials Engineering IPCSIT vol.15 (2011) (2011) IACSIT Press, Singapore Heat Transfer Analysis of Vapor Compression System Using Nano Cuo-R134a Eed Abdel-Hafez
More informationExperimental investigation of Hybrid Nanofluid on wickless heat pipe heat exchanger thermal performance
Experimental investigation of Hybrid Nanofluid on wickless heat pipe heat exchanger thermal performance #1 Jaydev S. Bade, #2 Dr. Nitin U. Korde 1 Department of Mechanical Engineering, Savitribai Phule
More informationDESIGN AND FABRICATION OF A PORTABLE REFRIGERATOR BASED ON PELTIER EFFECT
International Journal of Mechanical Engineering and Technology (IJMET) Volume 9, Issue 6, June 2018, pp. 242 247, Article ID: IJMET_09_06_028 Available online at http://www.iaeme.com/ijmet/issues.asp?jtype=ijmet&vtype=9&itype=6
More informationThermal Performance Enhancement of Inclined Rib Roughness Solar Air Heater
Thermal Performance Enhancement of Inclined Rib Roughness Solar Air Heater Gurpreet Singh and Satwant Singh Lala Lajpat Rai Institute of Engineering and Technology, Moga (Punjab) 142001 Abstract : Artificial
More informationTo investigate the surface properties for increasing efficiency of solar water heater
Journal of Physics: Conference Series OPEN ACCESS To investigate the surface properties for increasing efficiency of solar water heater To cite this article: A Hai and Qurat-ul-Ain 2013 J. Phys.: Conf.
More informationEXPERIMENTAL PERFORMANCE ANALYSIS OF SOLAR AIR HEATER WITH THREE DIFFERENT MODIFICATIONS IN ABSORBER PLATE
EXPERIMENTAL PERFORMANCE ANALYSIS OF SOLAR AIR HEATER WITH THREE DIFFERENT MODIFICATIONS IN ABSORBER PLATE ABSTRACT: 1 Chandan Kumar, 2 Hari Singh 1,2 Mechanical Engineering dept, Gyan Vihar University,
More informationA STUDY ON COMPACT HEAT EXCHANGERS AND PERFORMANCE ANALYSIS
A STUDY ON COMPACT HEAT EXCHANGERS AND PERFORMANCE ANALYSIS V. BHOGESWARA RAO Research Scholar Email:pallivayala@gmail.com Dr. S. CHAKRADHAR GOUD Principal, Sri Sarada Institute of Science and Technology
More informationThermal Performance of a Loop Thermosyphon
Tamkang Journal of Science and Engineering, Vol. 13, No. 3, pp. 281 288 (2010) 281 Thermal Performance of a Loop Thermosyphon Shung-Wen Kang*, Meng-Chang Tsai, Chih-Sheng Hsieh and Jian-You Chen Department
More informationDesign Based Comparative Study of Several Condensers Komal B. Dabhi 1, Prof. S. B. Thakore 2 1 Chemical Engg. Dept., L. D. College of Engineering, Ahmedabad 380015 2 Chemical Engg. Dept., L. D. College
More informationPerformance analysis of ejector refrigeration system with environment friendly refrigerant driven by exhaust emission of automobile
Available online at www.pelagiaresearchlibrary.com Advances in Applied Science Research, 2013, 4(5):232-237 ISSN: 0976-8610 CODEN (USA): AASRFC Performance analysis of ejector refrigeration system with
More informationEffect of Impeller Clearance and Multiple Impeller Combinations on Solid Suspension in a Standard Flat Bottom Agitated Vessel
International Journal of ChemTech Research CODEN( USA): IJCRGG ISSN : 0974-4290 Vol.6, No.2, pp 973-981, April-June 2014 Effect of Impeller Clearance and Multiple Impeller Combinations on Solid Suspension
More informationExperimental Analysis on Effect of Design Parameters on the Performance of Single Loop Pulsating Heat Pipe
Experimental Analysis on Effect of Design Parameters on the Performance of Single Loop Pulsating Heat Pipe Someshwar S. Bhakre 1, Md. Rafik Sajjadahmad Choudhari 2 1, 2 PG Scholar, Mechanical Engineering
More informationPressure drop analysis of Condenser using refrigerants R-134a, R-407C
Pressure drop analysis of Condenser using refrigerants R-134a, R-407C #1 Sachin N.Jadhav, #2 Dr. Pradeep A.Patil #12 Department of Mechanical Engineering, Savitribai Phule University of Pune, Pune, India.
More informationAn experimental study of the effect of evaporator temperature on the compressor work of a simple vapour compression refrigeration system
ISSN (ONLINE): 2321-3051 INTERNATIONAL JOURNAL OF RESEARCH IN AERONAUTICAL AND MECHANICAL ENGINEERING An experimental study of the effect of evaporator temperature on the of a simple vapour compression
More informationAmerican International Journal of Research in Science, Technology, Engineering & Mathematics
American International Journal of Research in Science, Technology, Engineering & Mathematics Available online at http://www.iasir.net ISSN (Print): 2328-3491, ISSN (Online): 2328-3580, ISSN (CD-ROM): 2328-3629
More informationFABRICATION OF REFRIGERANT FLOW RATE WITH SPIRALLY COILED CAPILLARY TUBE
FABRICATION OF REFRIGERANT FLOW RATE WITH SPIRALLY COILED CAPILLARY TUBE PRESENTED BY J.SARAVANA PERUMAL 1 Saravananjsp005@gmail.com D.SATHEESH 2 Satheeshd123@gmail.com Contact no: 9789080381 DEPARTMENT
More information